DC Components
Transcription
DC Components
R ® ELECTROTECHNOLOGY DC Components R ® DC Components 2013 Contents • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • DC - Distribution and Protection Components CH 10 gPV Fuse Selection / NH gPV Fuse Selection CH 10gPV - Fuse-Links CH 10x85 gPV - Fuse-Links CH 10x85 PV - Fuse-Links CH 10 PV - Fuse-Links CH 10 PV - Fuse-Links VLC 10 DC - Fuse Disconnector VLC 14 DC - Fuse Disconnector PCF 10 DC - Fuse Disconnector Section Rail / Fuseholder for 10 x 38 mm Fuse Links NH DC 750V - Fuse-Links NH DC 1000V - Fuse-Links NH DC 1100V - Fuse-Links Fuse Base U1-3 DC 1200V Fuse Base U1-3 DC 1200V Fuse Base U1-1/GZ/PV Fuse Disconnector TL1-1/9/1000V/PV Fuse Disconnector TL1,3-1/9/1200V Nh Strip-Fuseways L2,3-2/1200V Nh Strip-Fuseways L2,3-2/1200V Steel-Frame Clamp KM2G-F / NH Handle for Fuse Link DC 1100V Mertronic - Lightning and Surge Arresters / Mertronic PV Selection Mertronic B-PV 550/12,5 (10/350) / Mertronic B-PV 1000/12,5 (10/350) Mertronic C-PV for Photovoltaic System on a Building without External Lightning Protection Mertronic C - PV / Mertronic C-PV 100, 550/20 / Mertronic C-PV 1000/20 Technical Data PV Switch Disconnector for Photovoltaic / Switch Disconnectors and Load IP65 Wall Mounted Distribution Boards ECH Technical Data / Enclosure Designation 12 Modules PV Distribution Boards 1,2 Inputs / Type Designation / Electric Scheme PV 500 / B / 25 / 2 / PV 1000 / C / 25 / 2 24 Modules PV Distribution Boards (3,4,5,6 Inputs) PV1000/B/25/6 / PV500/C/25/6 Protection of PV Modules on REVERSE Current by CH gPV Fuse Link Protection of the Wiring Between ARRAYS from Short-Circuit Protection from “AC REVERSE Current” (Transformerless Inverter) Notes AC - Distribution and Protection Components ASTI - Miniature Circuit Breakers and Residual Current Devices Residual Current Circuit Breakers RCCBs EFI Type A EVE - Modular Devices / MERSWITCH - Switch Disconnectors Mertronic - Motor Contactors and MERBREAK - MCCBs Mertronic - Surge Arresters / NV/NH - Low Voltage Knife Blade Fuses and Disconnectors KVS - Free-Standing Cable Distribution Cabinets Enclosures Design on Customer’s Request Meter Distribution Cabinet / AC Collector Overcurrent and Overvoltage Protection for Wind Power Generation 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Contents DC - Distribution and Protection Components DC - Distribution and Protection Components Introduction Photovoltaic systems are composed by photovoltaic panels, cables, fuses, switches, overvoltage arresters and power inverter. Photovoltaic panels utilize the power of sunlight to converters photons to DC current. Electricity generated by solar panels is then fed into a power inverter that converts DC current to AC current. gPV fuse has been developed to protect cable and panel against «reverse» over current. MERTRONIC B, C-PV series of over voltage surge protective devices has been developed to protect against direct and indirect lightning discharges and is intended to protect photovoltaic systems. The circuit topology consists of two varistors stages each protected by a thermal disconnection device. Over Current Protection • PV module protection from »DC REVERSE« current on DC side Array with three or more strings of panels: PV systems that have three or more strings connected in parallel need to have each string protected by fuses. Systems that have less than three strings will not generate enough fault current to damage the conductors/solar panels. Normally there are two gPV fuses connected on each string (+ and - pole) that protect conductors/solar panels from damage and eliminate any safety hazards. Fuses isolate the faulted string. The rest of PV system can continue to generate electricity. • PV module protection from »AC REVERSE« current caused by defective inverter If an inverter becomes defective (transformer less …), AC reverse current can feed into DC strings and destroy PV modules. 2 | www.merkur-hamburg.de CH 10 gPV Fuse Selection / NH gPV Fuse Selection CH 10 gPV Fuse Selection Define panel data: - Isc (string) - Uoc (STC) - open circuit voltage at standard conditions - number of panels - number of strings Does module number in protected string exceed TWO? NO No gPV string fusing required YES gPV string fuse In! 1, 4 x Isc (panel) gPV string fuse Un! 1, 2 x Uoc (STC) (panel) x number of panels Apply gPV string fuse to + and - pole of string NH gPV Fuse Selection Define panel data: -Isc (panel) -Uoc (STC) - open circuit voltage at standard conditions -number of panels -number of strings NH PV fuse In ≥ 1,5 x Isc (panel) x number of strings NH PV fuse Un ≥ 1,2 x Uoc (STC) (panel) x number of panels Apply NH PV fuse to + and - pole of string www.merkur-hamburg.de | 3 CH 10gPV - Fuse-Links CH 10gPV - Fuse-Links General Characteristics Rated voltage Breaking capacity Standards Application UL file: E347771 1000V d.c. L/R=2ms 30kA d.c. IEC 60269-6 ed 1.0 (2010-9) For protection of photovoltaic modules CH 10 gPV Size In(A) Code No. «standard contacts» Code No. «type SU contacts» 10x38 1 2 3 3.5 4 5 6 7 8 10 12 13 14 15 16 20 25* 113736249 113736212 113736211 113736246 113736213 113736222 113736214 113736221 113736215 113736216 113736217 113736248 113736247 113736223 113736218 113736219 113736210 113736239 113736226 113736224 113736238 113736227 113736235 113736228 113736225 113736229 113736229 113736231 113736239 113736237 113736236 113736232 113736233 113736234 Pre-arcing Joule integral (A²s) L/R=2ms 0.8 1.3 2.6 3 4 7.4 10 13 17 21 28 30 31 33 35 50 75 Operating Joule integral (A²s) L/R=2ms 2.5 3.5 7.5 9.5 13 23 45 57 62 88 110 160 180 260 270 430 620 Power Power dissipation Weight Packaging dissipation (0,7xln) Pd (g) (pcs) (ln) Pd(W) (W) 0.4 1 0.52 1.25 0.55 1.3 0.48 1.16 0.52 1.25 0.63 1.49 0.73 1.65 0.79 1.92 10/500 10/12 0.84 2 SU:10/380 0.97 2.3 0.95 2.2 1 2.3 1.1 2.5 1 2.4 1.1 2.6 1.3 3 1.6 4 Standard Contacts *900V d.c. Type SU Contacts 4 | www.merkur-hamburg.de CH 10x85 gPV - Fuse-Links CH 10x85 gPV - Fuse-Links General Characteristics Rated voltage Breaking capacity Standards Application UL file: E347771 1500V d.c. L/R=2ms 30kA d.c. IEC 60269-6 ed 1.0 (2010-9) For protection of photovoltaic modules CH 10x85 gPV Size Standard Contacts In(A) 2 4 5 6 8 10x85 10 12 15 16 20* 25* *1200V d.c. Code No. «standard contacts» Code No. «type SU contacts» 113736311 113736312 113736340 113736313 113736314 113736315 113736316 113736351 113736317 113736318 113736319 113736321 113736322 113736310 113736323 113736324 113736325 113736326 113736320 113736327 113736328 113736329 Pre-arcing Joule integral (A²s) L/ R=1ms 1.6 7 11 21 22 53 41 49 141 212 273 Operating Joule integral (A²s) L/ R=1ms 2.2 11 13 37 80 119 82 240 230 408 570 Power Power dissipation Weight Packaging dissipation (0,7xln) Pd (g) (pcs) (ln) Pd(W) (W) 1.13 1.19 1.25 1.33 1.6 1.63 1.31 1.4 1.57 1.68 2.17 2.72 2.96 3.1 3.2 4.19 4.2 3.47 3.55 3.65 3.85 5 15/17 10/210 SU:10/160 Type SU Contacts www.merkur-hamburg.de | 5 CH 10x85 PV - Fuse-Links CH 10x85 PV - Fuse-Links General Characteristics Rated voltage Breaking capacity Standards Characteristic 1200V d.c. L/R=2ms 30kA d.c. IEC 60269-4 gR CH 10x85 PV Size In(A) Code No. «standard contacts» 10x85 2 4 6 8 10 12 16 20 25 113736331 113736332 113736333 113736334 113736335 113736336 113736337 113736338 113736339 Code No. «type SU contacts» 113736341 113736342 113736343 113736344 113736345 113736346 113736347 113736348 113736349 Pre-arcing Joule integral (A²s) L/ R=1ms 1.6 12.5 21 22 53 41 141 212 273 Operating Joule integral (A²s) L/ R=1ms 1.7 13 28 61 91 63 177 314 438 Power Power dissipation Weight Packaging dissipation (0,7xln) Pd (g) (pcs) (ln) Pd(W) (W) 1.13 1.19 1.33 1.60 1.63 1.31 1.57 1.68 2.17 2.74 2.96 3.20 4.19 4.20 3.47 3.65 3.85 5.00 15/17 10/210 SU:10/160 Standard Contacts Type SU Contacts 6 | www.merkur-hamburg.de CH 10 PV - Fuse-Links CH 10 PV - Fuse-Links General Characteristics Rated voltage Breaking capacity Standards Characteristic 700V a.c./d.c. L/R=2ms 30kA a.c./d.c. IEC 60269-4 gR CH 10 PV Size In(A) Code No. «standard contacts» 10x38 2 4 6 8 10 12 16 20 25 113736128 113736129 113736120 113736131 113736132 113736133 113736134 113736135 113736136 Standard Contacts Code No. «type SU contacts» 113736411 113736412 113736413 113736414 113736415 113736416 113736417 113736418 113736419 Pre-arcing Joule integral (A²s) L/ R=2ms 1.2 7.6 14 30 20 48 97 164 246 Operating Joule integral (A²s) L/ R=2ms 1.41 28 63 98 73 122 182 301 434 Power Power dissipation Weight Packaging dissipation (0,7xln) Pd (g) (pcs) (ln) Pd(W) (W) 0.44 0.55 0.73 0.70 0.98 0.82 1.06 1.27 1.61 1.10 1.30 1.70 1.62 2.44 1.85 2.61 3.00 4.00 10/12 10/500 SU:10/380 Standard Contacts CH 10 PV I/t characteristics www.merkur-hamburg.de | 7 CH 10 PV - Fuse-Links CH 10 PV - Fuse-Links General Characteristics (UL pending) Rated voltage 900V a.c./d.c. L/R=2ms Breaking capacity 30kA a.c./d.c. Standards IEC 60269-4 Characteristic gR CH 10 PV Size In(A) Code No. «standard contacts» 10x38 2 4 6 8 10 12 16 20 25 113736138 113736139 113736130 113736141 113736142 113736143 113736144 113736145 113736146 Code No. «type SU contacts» 113736421 113736422 113736423 113736424 113736425 113736426 113736427 113736428 113736429 Pre-arcing Joule integral (A²s) L/ R=2ms 1.2 7.6 14 30 20 48 97 164 246 Operating Joule integral (A²s) L/ R=2ms 1.89 37 81 126 94 157 234 387 558 Power Power dissipation dissipation (0,7xln) Pd (ln) Pd(W) (W) 0.44 0.55 0.73 0.70 0.98 0.82 1.06 1.27 1.61 1.10 1.30 1.70 1.62 2.44 1.85 2.61 3.00 4.00 Weight (g) Packaging (pcs) 10/12 10/500 SU:10/380 Standard Contacts Standard Contacts 8 | www.merkur-hamburg.de VLC 10 DC - Fuse Disconnector VLC 10 DC - Fuse Disconnector General Characteristics Rated voltage Rated current Max. fuse link power dissipation Cross section of connecting wir Pole build-in width Mouting on the rail Utilization category Standards Fuse-links Standards - Fuse disconnector UL file: E212627 1000V d.c. max. 25A 3W 1,5 mm²-25mm² 18 mm EN 60715 DC-20B IEC 60269-2:2006 UL 284-4 IEC 60947-1 Ed. 4.0 EN 60947-1:1999+A1+A2 IEC 60947-3 Ed. 2.1 EN 60947-3:1999+A1:2001 VLC 10 DC Number of poles 1P 2P 1P 2P Ue/Ui [V] 1000 1000 1000 1000 Imax.[A] 25 25 25 25 Code No. 113652113 113654113 113652213 113654213 Indicator LED LED Weight [g] 65 Packing [pcs] 12/108 6/54 12/108 6/54 www.merkur-hamburg.de | 9 VLC 14 DC - Fuse Disconnector VLC 14 DC - Fuse Disconnector General Characteristics Rated voltage Rated current Max. fuse link power dissipation Cross section of connecting wir Pole build-in width Mouting on the rail Utilization category Standards Fuse-links UL file: E212627 1000V d.c. max. 25A 3W 1,5 mm²-25mm² 18 mm EN 60715 DC-20B IEC 60269-2:2006 UL 284-4 IEC 60947-1 Ed. 4.0 EN 60947-1:1999+A1+A2 IEC 60947-3 Ed. 2.1 EN 60947-3:1999+A1:2001 Standards - Fuse disconnector VLC 14 DC Number of poles 1P 2P 1P 2P Ue/Ui [V] Imax.[A] Code No. Indicator Weight [g] 1000 1000 1000 1000 50 50 50 50 113672113 113674113 113672213 113674213 LED LED 100 10 | www.merkur-hamburg.de Packing [pcs] 12/96 6/48 12/96 6/48 PCF 10 DC - Fuse Disconnector PCF 10 DC - Fuse Disconnector General Characteristics Rated voltage Rated current Max. fuse link power dissipation Cross section of connecting wir Pole build-in width Mouting on the rail Utilization category Standards Fuse-links UL file: E212627 1000V d.c. max. 25A 3W 1,5 mm²-25mm² 18 mm EN 60715 DC-20B IEC 60269-2:2006 UL 284-4 IEC 60947-1 Ed. 4.0 EN 60947-1:1999+A1+A2 IEC 60947-3 Ed. 2.1 EN 60947-3:1999+A1:2001 Standards - Fuse disconnector PCF 10 DC Number of poles 1P 2P 1P 2P Ue/Ui [V] Imax.[A] Code No. Indicator Weight [g] 1000 1000 1000 1000 25 25 25 25 113661312 113661314 113661322 113661324 LED LED 58 120 58 120 Packing [pcs] 12/108 6/54 12/108 6/54 www.merkur-hamburg.de | 11 Section Rail / Fuseholder for 10 x 38 mm Fuse Links Section Rail PCF 10 DC, VLC 10 DC Type Description Code No. IZS10/1F/54 IZS16/1F/54 10mm², 1 pole, 54 mod 16mm², 1 pole, 54 mod 113032212 113032222 Cross section (mm²) 10 16 Length (m) Weight [g] Packing [pcs] 1 1 150 220 40 40 VLC 14 DC Type Description Code No. IZS16/1F/36 16mm², 1 pole, 36 mod 113032232 Cross section (mm²) 16 Length (m) Weight [g] Packing [pcs] 1 280 40 Fuseholder for 10 x 38 mm Fuse Links Fuseholder for 10 x 38 mm Fuse Links Code 117821446 Type HK10383 Type HK10383 A 12.3 B 9.8 Weight [g] 1 C 19 12 | www.merkur-hamburg.de Packing [pcs] 250 Dimensions[mm] D E 2.0 2.0 F 0.75 G 11.0 H 4.0 NH DC 750V - Fuse-Links NH DC 750V - Fuse-Links General Characteristics Rated voltage Breaking capacity Standards 750V d.c. (L/R=15ms) 20kA d.c. IEC 60269-6 ed 1.0 (2010-9), IEC 60269-4 Fuse-link for DC application. Applied in fuse base PK0 and PK1 DC. Application DC 750V In(A) 32 40 50 63 80 100 125 160 gPV Code No. Code No. Size 0 Size 1C 115221419 115221411 115221421 115221412 115221422 115221413 115221423 115221414 115221424 115221415 115221425 115221416 115221426 115221417 115221427 115221418 Size 0 1C PV (gR) Power Code No. Code No. dissipation [W] Size 0 Size 1C 115221611 115221621 7.6 115221613 115221623 8.8 115221614 115221624 11.0 115221615 115221625 13.5 115221616 115221626 17.0 115221617 115221627 21.0 115221618 115221628 22 115221619 115221629 22.8 A 125 135 B 35 40 C 50 55 Pre-arcing Joule integral [I²t] (L/ R=15ms) Operating Joule integral [I²t] (L/ R=15ms) Weight (g) Packaging (pcs) 70 135 250 520 1,050 2,580 6,300 13,060 370 650 1,000 1,790 3,000 6,140 14,090 27,220 280/0 300/1C 3/24 D 60 65 www.merkur-hamburg.de | 13 NH DC 1000V - Fuse-Links NH DC 1000V - Fuse-Links General Characteristics Rated voltage Breaking capacity Standards Application 1000V d.c. (L/R=2ms) 20kA d.c. IEC 60269-6 ed 1.0 (2010-9), IEC 60269-4 Fuse-link for DC application. Applied in fuse base PK0 and PK1 DC. DC 1000V gPV In(A) 32 40 50 63 80 100 125 160* *900V d.c. PV (gR) Code No. Size 0 Code No. Size 1C Code No. Size 0 Code No. Size 1C Power dissipation [W] 115221492 115221494 115221495 115221496 115221497 115221498 115221499 115221490 115221482 115221484 115221485 115221486 115221487 115221488 115221489 115221480 115221631 115221633 115221634 115221635 115221636 115221637 115221638 115221639 115221641 115221643 115221644 115221645 115221646 115221647 115221648 115221649 7.6 8.8 11.0 13.5 17.0 21.0 22 22.8 Size 0 1C 14 | www.merkur-hamburg.de A 125 135 Pre-arcing Joule integral [I²t] (L/ R=2ms) 52 96 155 290 520 1,110 2,800 5,950 B 35 40 C 50 55 Operating Joule integral [I²t] (L/ R=2ms) 430 730 920 1,760 3,160 5,280 11,340 20,750 D 60 65 Weight (g) Packaging (pcs) 280/0 300/1C 3/24 NH DC 1100V - Fuse-Links NH DC 1100V - Fuse-Links General Characteristics Rated voltage 1100V d.c. (L/R=5ms) Breaking capacity 10kA d.c. Standards IEC 60269-6 ed 1.0 (2010-9), IEC 60269-4 Application Fuse-link for DC application. Applied in fuse base U1-3-1/1200/H DC 1100V gPV Trip indicator - K (pic. 2) 115221542 115221543 115221544 115221545 115221525 115221527 115221526 115221528 115221520 115221553 115221554 / S170 screw contact (pic. 3) 115221546 115221547 115221548 115221549 115221531 115221540 115221532 115221534 115221535 115221555 115221556 115221558 PV (gR) Standard Trip indicator indicator - K (pic 1) (pic. 2) 115221651 115221661 115221652 115221662 115221653 115221663 115221654 115221664 115221655 115221665 115221696 115221697 115221656 115221666 115221657 115221667 115221658 115221668 115221659 115221669 115221650 115221660 / / Power dissipation (0,7xIn) Pd [W] Power dissipation [W] Pre-arcing Joule integral [I²t] (L/R=5ms) Operating Joule integral [I²t] (L/R=5ms) 6.2 7.0 8.2 9.6 14.6 13.9 17.8 17.9 25.2 28.2 28.8 37.7 15.0 17.0 20.0 23.0 35.0 32.6 42 46 54.0 60.5 67.0 80.8 2,720 4,000 6,500 11,000 19,400 42,600 40,000 85,260 166,800 175,000 235,000 493,000 3,520 5,500 9,000 15,000 28,640 83,400 60,000 117,400 221,900 260,000 345,000 584,000 Weight (g) Packaging (pcs) 750 1/16 1050 1/15 1360 1/22 2 # ' Picture 1 0 " Standard Size In(A) indicator (pic. 1) 63 115221537 80 115221538 100 115221539 1XL 125 115221540 160 115221521 200 115221522 200 115221541 2XL 250 115221524 315 115221536 350 115221551 3L 400 115221552 500* 115221557 *1000V d.c., L/R=2ms % ! Picture 2 Picture 3 Size 1XL 2XL 3L A 194 209 209 B 24 30 37 C 40 48 60 Dimensions[mm] E G P 46 61.5 20.5 54 71 27.3 64 82 35.6 R 13.7 16.2 17.0 M 50 59 70 O 52 61 74 www.merkur-hamburg.de | 15 Fuse Base U1-3 DC 1200V 104 6 4 80A 125A 63A 100A 160A 103 NH1 200 A A 200 6 4 315A 250A 350A 500A 400A NH2 Pre-arcing time (s) tv/s 2 2 102 6 4 2 101 6 4 2 100 6 4 2 10-1 6 4 2 10-2 6 102 2 4 6 103 2 Prospective current (A) Ip/A 4 6 gPV, PV(gR) 750V, 1000V t-I Characteristics gPV, PV(gR) 1100V t-I Characteristics Fuse Base U1-3 DC 1200V General Characteristics Type Rated voltage Rated current fuse links size Conv. Free air thermal current with fuse-links Conv. Free air thermal current with solid links Max. permis. Power dissipation per fuse-link Screw Cable lug (DIN46235) Flat terminal Flat termination Cable terminal Rated torque Clamping cross-section Terminal Rated torque Degree of protection - Front side, device fitted Ambient temperature* Rated operating mode Actuation Operating Mounting position conditions Altitude Pollution degree Overvoltage category Insulation class Standards 16 | www.merkur-hamburg.de U1-1/1200 U2-1/1200 U3-1/1200 1200V d.c. 250A 1XL 200A 325A 35W M10 25-150mm² 30x10 mmx-mm 30-35Nm KM2G IP 00 400A 2XL 315A 520A 46W M10 25-240mm² 30x10 mmx-mm 30-35Nm 25-300mm² 32Nm KM2G 630A 3L 630A 1000A 70W M10 25-300mm² 40x10 mmx-mm 30-35Nm 25-300mm² 32Nm IP 00 -25°C to +55°C Continuous operation Vertical, horizontal up to 2000 m 3 III C-VDE 0110 EN 60269, IEC 60269, DIN VDE 0636, DIN 43620, DIN 43623 IP 00 Fuse Base U1-3 DC 1200V A Fuse Base U1-3 DC 1200V C B K H 10.5 30 Type In(A) Code No. U1-232/1200/H U1-1/1200/H U1-1/1200/H/K U2-1/1200/H U2-1/1200/H/K U3-1/1200 U3-1/1200/K 250 250 250 400 400 630 630 115233145 115233138 115233139 115233130 115233141 115233142 115233143 A 56 56 64 68 B 232 257 257 270 Type I U1-232/1200/H U1-1/1200/H U2-1/1200/H U3-1/1200 E D F G C 140 140 140 140 Max. Connection (mm²) 150 150 150 240 240 300 300 D 25 25 30 40 Mechanical fuse monitor Weight (g) without without with without with without with 500 550 600 930 1000 1200 1250 Dimensions[mm] E F 37 84.5 37 84.5 37 100 38 103 Packaging (pcs) 2 1 G 96 96 103 - H 17.5 17.5 17.5 25 I M10 M10 M10 M12 K 262 287 287 307 I 25 25 J 10 4.5 K 200 170 M 26 20 Fuse Base U1-3 DC 1200V General Characteristics Rated voltage 1000V d.c. Rated current 160A, 250A Insulation class C-VDE 0110 EN 60269, IEC 60269, DIN VDE 0636, DIN 43620, DIN Standards 43623 Type PK1 DC PK0 DC In [A] 250 160 Code No. 115233136 115233136 Weight [g] 598 258 Type PK1 DC PK0 DC Packing [pcs] 3/42 3/90 A 175 150 B 80 74 C 141 130 D 81 60 Dimensions[mm] E F G M10 ø 10, 5 30 M8-M8 ø 7, 5 - H 55 33 www.merkur-hamburg.de | 17 Fuse Base U1-1/GZ/PV Fuse Base U1-1/GZ/PV General Characteristics Rated voltage Rated current fuse links size Conv. Free air thermal current with fuse-links Conv. Free air thermal current with solid links Max. permis. Power dissipation per fuse-link Screw Cable lug (DIN46235) Cable terminal Flat terminal Flat terminal Flat termination Rated torque 1000V d.c. 160A 1C, 1 160A 325A 31W M10 25-150mm² 30x10 mmx-mm 30-35Nm Fuse Disconnector TL1-1/9/1000V/PV Type In [A] Code No. U1-1/GZ/PV 160 115233146 18 | www.merkur-hamburg.de Max. Connection (mm²) 150 Weight [g] Packing [pcs] 387 1 Fuse Disconnector TL1-1/9/1000V/PV Fuse Disconnector TL1-1/9/1000V/PV General characteristics Number of poles Rated voltage Rated current Conv. Free air thermal current with fuse-links Utilization category Fuse-links Size to DIN 43620 Max. rated current (gL/gG) Max. permis. Power loss per fuse-link Screw Cable lug (DIN 46235) Cable terminal Flat termination Rated torque Type of protection - front side, device fitted Ambient temperature* Rated operating mode Actuation Operating conditions Mounting position Altitude Pollution degree Overvoltage category 1 1000V d.c. 160A 160A DC-20B 1C,1 160A 25W M10 25-240mm² 30x10 mm 30-35Nm IP20, IP10 -25 to +55 Cont. operation Dependent manual actuation Vertical, horizontal up to 2000 m 3 III Fuse Disconnector TL1-1/9/1000V/PV Type In [A] Code No. Max. Connection (mm²) Terminal Weight [g] Packing [pcs] TL1-1/9/1000V/ PV 160 115233149 150 M10 387 1 119 69 68 117 317 230 Ø 10.,5 25 115 102,5 230 Ø 10.,5 16.5 69 30 25 www.merkur-hamburg.de | 19 Fuse Disconnector TL1,3-1/9/1200V Fuse Disconnector TL1,3-1/9/1200V General Characteristics Type For NH fuse-lins/extended length/acc. To DIN VDE 0636-2 Rated voltage Rated current fuse link size Conv. Free air thermal current with fuse-links Conv. Free air thermal current with solid links Rated frequency Utilization category Max. permis. Power loss per fuse-link Size Bolt diameter Cable lug (DIN 46235) Flat bar Rated torque Operating condition Switching cover open Ambient temperature* Rated operating mode Actuation Mounting position Altitude Pollution degree Overvoltage category Cable terminal-Flat terminal Type of protection - front side, device fitted Operating conditions TL1/1200V TL3/1200V a1=194mm, a4=124mm a1=209mm, a4=124mm 1200V a.c. / 1000V d.c. 1200V a.c. / 1000V d.c. 250A 630A 1XL 2XL, 3L 250A 630A 325A 1000A 40-60Hz 40-60HZ AC-20B, DC-20B AC-20B, DC-20B 25W 70W M10 M12 25-150mm² 25-300mm² 30x10 mm 40x10 mm 30-35Nm 30-35Nm IP20 IP20 IP10 IP10 -25 to +55 Cont. operation Dependent manual actuation Vertical, horizontal up to 2000 m 3 III *35°C normal temperature, 55°C with reduced operating current Fuse Disconnector TL1,3-1/9/1200V Type In [A] Code No. TL1-1/9/1200V TL3-1/9/1200V 250 630 115233147 115233148 Max. Connection (mm²) 150 300 Terminal Weight [g] Packing [pcs] M10 M12 1485 2535 1 1 Flat Terminal M10x25 20 | www.merkur-hamburg.de Nh Strip-Fuseways L2,3-2/1200V TL3-1/9/1200V Flat Terminal M10x25 Nh Strip-Fuseways L2,3-2/1200V General Characteristics Type For NH fuse-links acc. to IEC 60269-6 Size Rated voltage Rated current fuse links size Conv. Free air thermal current with fuse-links Rated insulation voltage Max. permis. Power loss per fuse-link Flat terminal Cable terminal Clamp KM2G Clamp KM2G-F Type of protection- front side, device fitted - with front side strip cover Ambient temperature* Rated operating mode Actuation Operating conditions Mounting position Altitude Pollution degree Overvoltage category *35°C normal temperature, 55°C with reduced operating current Bolt diameter Cable lug (DIN46235) Flat bar Tightening torque Clamping cross-section Tightening torque Clamping cross-section Tightening torque L2 L3 2 (extended 3 (extended body) body) 1200V d.c. 1200V d.c. 250A 400A 1XL, 2XL 3L 250A 400A 1200V d.c. 1200V d.c. 46W 75W M12 M12 1x25-240mm² 1x25-240mm² 30x10 mm 30x10 mm 35-40Nm 35-40Nm 2525150mm²/185150mm²/185300 mm² 300 mm² 32Nm 32Nm 25-240 mm² 25-240 mm² 32 Nm 32 Nm IP 10 IP 10 -25 to +55 Cont. Operation Dependent manual operation Vertical up to 2000 m 3 III www.merkur-hamburg.de | 21 Nh Strip-Fuseways L2,3-2/1200V Nh Strip-Fuseways L2,3-2/1200V General Characteristics Type L2-2/1200/3A/HA/PV L2-2/1200/9/KM2G-F/HA/PV L3-2/1200/3A/HA/PV L3-2/1200/9/KM2G-F/HA/PV 22 | www.merkur-hamburg.de In(A) Code No. 250 250 400 400 115233140 115233151 115233151 115233153 Max. Connection (mm²) 25-240 25-240 25-240 25-240 Terminal Weight (g) Packaging (pcs) 2.5 3.5 7.5 9.5 3500 3650 4110 4260 1 1 1 1 Steel-Frame Clamp KM2G-F / NH Handle for Fuse Link DC 1100V Steel-Frame Clamp KM2G-F NH Handle for Fuse Link DC 1100V NH Handle for Fuse Link DC 1100V Code Type 115052223 GP 1200 Weight (g) 400g Packing (pcs) 1 www.merkur-hamburg.de | 23 MERTRONIC - Lightning and Surge Arresters / ETITEC PV Selection MERTRONIC - Lightning and Surge Arresters Overvoltage Protection Selection MERTRONIC PV Selection Define PV System data: - Umax External Lighting protection exist? Uc> 1,2xUmax NO Apply MERTRONIC C PV on string and on inverter side YES Apply MERTRONIC B PV on string and inverter side MERTRONIC B-PV for Photovoltaic System on a Building with External Lightning Protection PV + + - - - L ~ N PE MERTRONIC B-PV T - Connection MERTRONIC B-PV 24 | www.merkur-hamburg.de MERTRONIC B-PV V - Connection MERTRONIC B-PV MERTRONIC B-PV 550/12,5 (10/350) / MERTRONIC B-PV 1000/12,5 (10/350) MERTRONIC B-PV series of overvoltage surge protective devices has been developed to protect against direct and indirect lightning discharges and is intended to protect photovoltaic systems. The circuit topology consist of two varistors stages each protected by a thermal disconnection device. General Characteristics Category IEC/EN/VDE Class I,II/Type 1,2/B+C Location of use: Photovoltaic systems-PV module side Protective element: High Engery MOVs General Characteristics Type MERTRONIC B-PV 550/12,5 (10/350) MERTRONIC B-PV 1000/12,5 (10/350) MERTRONIC B-PV 550/12,5 (10/350) RC MERTRONIC B-PV 1000/12,5 (10/350) RC RC - Remote signalization contracts Code No. 125556325 125556314 125556315 125556316 MERTRONIC B-PV 550/12,5 (10/350) High surge discharge ratings, Ilmp =12,5kA/pole, Imax =40kA/ per pole Internal protection and safety: Separate thermal disconnector for each MOV block Status indication: Mechanical flag + remote signalization contacts (RC) Uc [V DC] 550 1000 550 1000 Iimp [kA] 12.5 Weight (g) 300 350 310 360 Packaging (pcs) 1/3 MERTRONIC B-PV 1000/12,5 (10/350) www.merkur-hamburg.de | 25 Technical Data Technical Data Type In accordance with Max. contionous operating voltage Uc(DC) Nominal discharge current In(8/20) Max. discharge current Imax (8/20) Impulse current Iimp (10/350) Specific energy Charge Protection level Up at In (8/20) Protection level Up at Iimp (10/350) Follow current If Response time tA Residual current at Uc Thermal protection Short-circuit withstand current Temperature range Terminal cross section Terminal screw torque Mounting EN 60715 Degree of protection Housing material Dimensions DIN 43880 Remote contacts - type ….RC Contacts ratings Terminal cross section Terminal screw torque Packaging dimensions MERTRONIC B-PV xxxx/12,5 (10/350) 550V 1000V IEC-61643-1 550V 1000V 20kA 20kA 40kA 40kA 12,5kA 12,5kA 39kJ/Ω 39kJ/Ω 6,25 As 6,25 As < 2,0kW < 2,6kW <1,7 kW < 2,4 kW No <25 ns < 2,5 mA yes 25 kA / 50Hz -40°C+80°C 35 mm² (solid)/25 mm² (stranded) Max. 4,5 Nm 35 mm top-hat rall IP 20 Thermoplastic, exthinguishing degree UI 94 V-0 4 TE AC 250V /0,5A; 125V/2A Max. 1,5 mm² 0,25 Nm 108 mm x 79 mm x 76 mm MERTRONIC C-PV for Photovoltaic System on a Building without External Lightning Protection PV + + - - - L ~ N PE 2 X MERTRONIC C-PV 100V/550V PV + + - - L ~ N PE 2 X MERTRONIC C-PV 1000V T Connection MERTRONIC C-PV V Connection MERTRONIC C-PV Note: If distance between string and inverter is less than 7 m, then you need only one MERTRONIC (B,C). 26 | www.merkur-hamburg.de MERTRONIC C - PV MERTRONIC C-PV series of overvoltage surge protective devices has been developed to protect against indirect discharges and is intended to protect photovoltaic systems. The circuit topology consist of two (three) varistors stages each protected by a thermal disconnection device. General Characteristics Category IEC/EN/VDE Class II/Type 2/C Location of use: Branch sub-distribution boards Protective element: High Engery MOVs MERTRONIC C - PV Type MERTRONIC C-PV 100/20 MERTRONIC C-PV 550/20 MERTRONIC C-PV 1000/20 MERTRONIC C-PV 100/20 RC MERTRONIC C-PV 550/20 RC MERTRONIC C-PV 1000/20 RC MODULE MERTRONIC C-PV 100/20 MODULE MERTRONIC C-PV 550/20 MODULE MERTRONIC C-PV 1000/20 RC - Remote signalization contracts Code No. 125556317 125556318 125556319 125556310 125556321 125556322 125556332 125556333 125556334 MERTRONIC C-PV 100, 550/20 High surge discharge ratings, Iln =20kA/ pole, Imax =40kA/per pole Internal protection and safety: Thermal disconnector for each MOV block Status indication: Mechanical flag + remote signalization contacts (RC) Uc [V DC] 100 550 1000 100 550 1000 100 550 1000 Iimp [kA] 20 Weight (g) 200 255 365 210 265 375 52 52 52 Packaging (pcs) 1/7 1/7 1/5 1/7 1/7 1/85 12/24 12/24 12/24 MERTRONIC C-PV 1000/20 www.merkur-hamburg.de | 27 Technical Data Technical Data Type In accordance with Max. contionous operating voltage Uc(DC) Nominal discharge current In(8/20) Max. discharge current Imax (8/20) Impulse current Iimp (10/350) Specific energy Charge Protection level Up at In (8/20) Protection level Up at Iimp (10/350) Follow current If Response time tA Residual current at Uc Thermal protection Short-circuit withstand current Temperature range Terminal cross section Terminal screw torque Mounting EN 60715 Degree of protection Housing material Dimensions DIN 43880 Remote contacts - type ….RC Contacts ratings Terminal cross section Terminal screw torque Packaging dimensions 28 | www.merkur-hamburg.de MERTRONIC B-PV xxxx/12,5 (10/350) 100 V 550V 1000V IEC-61643-1 100V 550V 1000V 20kA 20kA 20kA 40kA 40kA 40kA < 0,7 kV < 2,1 kV < 4,0kV No <25 ns < 1,5 mA yes 25 kA / 50Hz -40°C+80°C 35 mm² (solid)/25 mm² (stranded) Max. 4,5 Nm 35 mm top-hat rall IP 20 Thermoplastic, exthinguishing degree UI 94 V-0 2 TE 2 TE 3 TE AC 250V /0,5A; 125V/2A Max. 1,5 mm² 0,25 Nm 108 mm x 79 mm x 76 mm PV Switch Disconnector for Photovoltaic / Switch Disconnectors and Load General Characteristics The construction of the switch ensures reliable switching up to 58A with 1000V in the category DC 21B. The construction of the contacts and the material selection guarantee that no oxidation (small switching frequency develops, and is thus prevented inadmissible heating-up. The switch disconnector has 2, 4 or 4+2 contacts, by serial / paralel wirring of the contacts the contact rating will be increased. The switching speed at the manually operated handle does not have an effect on the switching attitude of the contacts. General Characteristics Rated voltage Rated current Standards Up to 1000V d.c. Up to 58A d.c. IEC 60364-7-712 For interupting the DC/AC inverter from the solar panels Applications PV Switch Disconnector for Photovoltaic Code Type Weight (g) 115771171 115771172 115771173 115771174 115771175 115771176 115771177 LS16 SMA A2 LS25 SMA A2 LS32 SMA A2 LS16 SMA A4 LS25 SMA A4 LS32 SMA A4 LS32 SMA A4 + 2 Packing (pcs) 2-pole 150 1 4-pole 4+2 pole 430 Switch Disconnectors and Load DC 21B Technical data according to IEC 60947-3, VDE0660 LS16.. LS25.. LS32.. LS32..A4+2 500V 600V 800V 1000V 2 poles in series 16A 16A 16A 9A 4 poles in series 16A 16A 16A 16A 2 poles in series 25A 25A 20A 11A 4 poles in series 25A 25A 25A 25A 2 poles in series 32A 32A 23A 25A 4 poles in series 32A 32A 32A 32A 4 Poles in series + 2 poles parallel 58A 58A 58A 58A Because of very high breaking point capacity, switch disconnectors «LS…» are suitable for many different operating conditions www.merkur-hamburg.de | 29 IP65 Wall Mounted Distribution Boards ECH IP65 Wall Mounted Distribution Boards ECH Available in 4, 8, 12, 24, 36 modules Applications: Watertight wall-mounted distribution boards apply in domestic and industry architecture for mounting modular equipment for protection (IP65) against wet, dust and another dirtiness Structure: Enclosure is made of high thermal stability material - ASA (Acrylonitrile-Acrylic-Styrene), plastic with good dielectrical and mechanical attributes, UV resistant (colour stability) Advantages: Aesthetic and attractive look, easy and quick montage Main elements: - Bottom cover with DIN rail, PE and N bars and holes for PG cable inlets properly marked - Top cover with seal of the door - Transparent door made of polycarbonate (PC) with plastic lock (in standard) or metal lock with key (in option) 30 | www.merkur-hamburg.de Technical Data / Enclosure Designation Technical Data: Protection class Isolation class Impact kit Nominal voltage Temperature range IEC compatibility Type Code number ECH-4G 112212171 ECH-8G 112212172 ECH-12PT 112212173 ECH-24PT 112212174 ECH-36PT 112212175 Accessories ECH-Lk 112212176 IP65 II IK 07 400V AC -25°C do +60°C IEC-60670-24 Œ Description Wall mounted encl. 4 mod, IP-65 transparent door Wall mounted encl. 8 mod, IP-65 transparent door Wall mounted encl. 12 mod, IP-65 transparent door Wall mounted encl. 24 mod, IP-65 transparent door Wall mounted encl. 36 mod, IP-65 transparent door Number of terminals at PE/N Dimensions (HxWxD) (mm) Weight (kg) Packaging (pcs.) 4/4 201x128x120 0.46 1/5 8/8 201x202x120 0.68 1/5 10/10 256x319x144 1.24 1/5 15/15 384x319x144 1.7 1/5 15/15 535x319x144 2.31 1/5 - - 0.017 1 Lock with key for ECH Enclosure Designation Type E C H ...G ...PT Vertical door opening ( 4 or 8 modules) Horizontal door opening (12, 24 or 36 modules) Modules (4, 8, 12, 24, 36) www.merkur-hamburg.de | 31 12 Modules PV Distribution Boards 1,2 Inputs 12 Modules PV Distribution Boards 1,2 Inputs General Characteristics Rated voltage 500V, 1000V d.c. Rated current 25A, 25A d.c. Standards IEC 60364-7-712:2005, EN60439-1, Type test ICEM-TC Maribor Protection class IP54 Category(switch) DC21B Isolation class Temperature range -25°C to + 60°C Application As PV distribution board in photovoltaic power plant Overvoltage Protection Voltage Inputs 1 2 1 2 1 2 1 2 B 500V d.c. C 12 modules (318x258x142mm) B 1000V d.c. C Overvoltage Protection Type B Type C 13a D.C. 112214112 112214125 112214116 112214117 112214110 112214121 112214124 112214125 Ground Cable 16mm² 6mm² 25a D.C. PV500/25/B/1 PV500/25/B/2 PV500/25/C/1 PV500/25/C/2 PV1000/25/B/1 PV1000/25/B/2 PV1000/25/C/1 PV1000/25/C/2 112214128 112214129 112214252 112214253 112214256 112214257 112214250 112214141 PV500/25/B/1 PV500/25/B/2 PV500/25/C/1 PV500/25/C/2 PV1000/25/B/1 PV1000/25/B/2 PV1000/25/C/1 PV1000/25/C/2 Weight (g) Pack. 1860 1980 1860 1980 1860 1980 1860 1980 1 Important ! CH 10 gPV fuse-links are not included in the distribution board package and need to be ordered separately. Type Designation Electric Scheme: Nominal D.C. Voltage Type of Overvoltage Protection LS xx SMA A2 4 2 3 1 MERTRONIC C PV 1000 / 25 / B / 2 F2 PE F1 F1 F2 INVERTER String 6mm2 Nr. of Inputs Nominal D.C. Current 32 | www.merkur-hamburg.de - + String PV 500 / B / 25 / 2 / PV 1000 / C / 25 / 2 PV 500 / B / 25 / 2 1 2 3 4 5 6 7 8 9 10 11 12 3 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 5 4 28 29 30 6 INVERTER + MERTRONIC B-PV PE STRING INPUTS STRING INPUTS 2 1 Ser. Nr. xxx PV 1000 / C / 25 / 2 1 2 3 4 5 6 7 8 9 10 11 12 3 2 13 14 15 16 17 18 19 20 21 5 4 22 23 24 25 26 27 6 7 28 29 30 INVERTER + 1 STRING INPUTS PE - STRING INPUTS Ser. Nr. xxx www.merkur-hamburg.de | 33 24 Modules PV Distribution Boards (3,4,5,6 Inputs) 24 Modules PV Distribution Boards (3,4,5,6 Inputs) General Characteristics Rated voltage 500V, 1000V d.c. Rated current 13A, 25A d.c. IEC 60364-7-712:2005, EN 60439-1, Standards Type test ICEM-TC Maribor Protection class IP54 Category (switch) DC 21B Isolation class II ⧈ Temperature range -25 °C to +60°C Application As PV distribution board in photovoltaic power plant Important! CH 10 gPV fuse-links are not included in the distribution board package and need to be ordered separately. Overvoltage Protection Voltage B 500V d.c. C 24 modules (318x383x142mm) B 1000V d.c. C Inputs 13a D.C. 3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6 112214176 112214177 112214178 112214179 112214184 112214185 112214186 112214187 112214192 112214193 112214194 112214195 112214190 112214101 112214102 112214103 25a D.C. PV500/13/B/3 PV500/13/B/4 PV500/13/B/5 PV500/13/B/6 PV500/13/C/3 PV500/13/C/4 PV500/13/C/5 PV500/13/C/6 PV1000/13/B/3 PV1000/13/B/4 PV1000/13/B/5 PV1000/13/B/6 PV1000/13/C/3 PV1000/13/C/4 PV1000/13/C/5 PV1000/13/C/6 112214144 112214145 112214146 112214147 112214152 112214153 112214154 112214155 112214150 112214161 112214162 112214163 112214168 112214169 112214160 112214171 Pack. 2560 2680 2800 2920 2560 2680 2800 2920 2560 2680 2800 2920 2560 2680 2800 2920 1 PV500/25/B/3 PV500/25/B/4 PV500/25/B/5 PV500/25/B/6 PV500/25/C/3 PV500/25/C/4 PV500/25/C/5 PV500/25/C/6 PV1000/25/B/3 PV1000/25/B/4 PV1000/25/B/5 PV1000/25/B/6 PV1000/25/C/3 PV1000/25/C/4 PV1000/25/C/5 PV1000/25/C/6 Overvoltage Protection Type B Type C Electric Scheme: Weight (g) Ground Cable 16mm² 6mm² LS xx SMA A4 6 2 4 8 5 1 3 7 MERTRONIC C - + F6 F5 F4 F3 F2 F1 F1 INVERTER 34 | www.merkur-hamburg.de F3 F4 F5 PE 6mm2 String F2 String F6 PV1000/B/25/6 / PV500/C/25/6 PV1000/B/25/6 1 2 3 4 5 6 7 8 9 10 11 12 4 13 14 15 16 17 18 19 20 21 5 2 22 23 24 25 26 27 28 29 30 7 3 6 INVERTER + MERTRONIC B-PV PE 1 min. 9mm STRING INPUTS STRING INPUTS Ser. Nr. xxx PV500/C/25/6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 5 3 25 26 27 28 29 30 4 6 INVERTER + - PE 1 2 STRING INPUTS min. 9mm STRING INPUTS Ser. Nr. xxx www.merkur-hamburg.de | 35 Protection of PV Modules on REVERSE Current by CH gPV Fuse Link Protection of PV Modules on REVERSE Current by CH gPV Fuse Link CH10 gPV (panel and cable protection) NH DC (cable protection) String 1 F1 array 1 (I1- I11 )….In String 2 F2 I12 String n se lec tiv ity I2….In I1n Fn F1 String 1 array 2 F1 String 2 F2 I2 F2 Fn String n Fn DC box In F1 array n String 1 String 2 String n F2 Fn Main junction boxes 36 | www.merkur-hamburg.de DC AC Protection of the Wiring Between ARRAYS from Short-Circuit Protection of the Wiring Between ARRAYS from Short-Circuit F1 String 1 array 1 NH DC (cable protection) String 2 String n F2 I2….In I1 Fn F1 String 1 array 2 F1 String 2 F2 I2 DC F2 AC Fn String n Fn DC box In F1 array n String 1 String 2 String n F2 Fn Main junction boxes www.merkur-hamburg.de | 37 Protection from “AC REVERSE Current” (Transformerless Inverter) Protection from “AC REVERSE Current” (Transformerless Inverter) F1 String 1 String 2 F2 DC AC AC String n 38 | www.merkur-hamburg.de Fn Notes www.merkur-hamburg.de | 39 AC - Distribution and Protection Components AC - Distribution and Protection Components This part of the catalogue is only for informational purposes. All required commercial and technical information on the following products is available in our General Catalogue and in Leaflet Special Purpose Fuses. 40 | www.merkur-hamburg.de ASTI - Miniature Circuit Breakers and Residual Current Devices ASTI - Miniature Circuit Breakers and Residual Current Devices Advantages of Miniature Circuit Breakers TRONIC11 ➔ Sealing Cover ➔ Available in versions: 1-p, 1-p+N, 2-p, 3-p, 3-p+N with a wide range of accessories ➔ New special version TRONIC11 remote control (RC) is a miniature circuit breaker with remote control mechanism. ➔ Sealing Possibility ➔ “ON/OFF” mark on the switch button ➔ Locking Device ➔ Better protection of terminals against touching the parts under voltage ➔ Rated current: Characteristic B; 6 - 63 A Characteristic C; 0,5 - 63 A Characteristic D; 0,5 - 32 A Characteristic K; 0,5 - 32 A ➔ New method of mounting on the DIN rail and simple replacement ➔ Double connection possibility ➔ Every product is marked with EAN code www.merkur-hamburg.de | 41 Residual Current Circuit Breakers RCCBs EFI Type A Residual Current Circuit Breakers RCCBs EFI Type A Application: L1 DC L2 RCD AC L3 N EFI type A can be used in DC/AC inverters with transformers or in DC/AC inverters for which the producer excludes the possibility of DC leakage currents on AC side. EFI 4 Type S EFI 2 Type A Type A For alternating and pulsating direct residual current √ √ Short-circuit capacity with back-up fuse √ √ √ √ Lower temperature limit of application -25°C √ √ √ √ VDE 0664, part 1 (up to 80 A) √ √ Selective (time delayed min. 40 ms) Unwanted tripping Type UT √ √ √ Note: Tripping time according to standard IEC 61008 EFI-4 UT and EFI-4 S RCCB EFI-4 UT is surge current resistant type UT (unwanted tripping) up to 5kA 8/20μs. RCCB type A (Un 230/400V AC, 230V AC) recognizes sinusoidal alternating and pulsating direct residual currents (according to IEC/ EN 61008). RCCB EFI-4 S (selective) time delayed to exclude unwanted tripping because of possible occurance of short time leakage currents. 42 | www.merkur-hamburg.de EVE - Modular Devices / MERSWITCH - Switch Disconnectors EVE - Modular Devices Utility grid monitoring relays HRN-54 and HRN-54N serves to monitor voltage, phase failure and phase sequence and perform anti-islanding protection together with ETI multifunction time relays CRM-91H and CRM-93H. • HRN-54 • HRN-54N • CRM-91H • CRM-93H Application: Anti-islanding protection for photovoltaic systems. Build-in switch is used as a main switch in distribution boxes in houses or as a switch for individual electric circuits. With a build-in switch we can completely replace the cam switch. Build-in switch can be sealed either in ON or OFF position. Available in 1-, 2-, 3- and 4-pole versions. MERSWITCH - Switch Disconnectors MERSWITCH Switch diconnectors series LAS and built-in switches series SV serves as control switches, load break switches and disconnecting devices in AC distribution/protection cabinets. • LAS16 up to LAS125 (3,4-pole, from 16 to 125A) • SV1100 up to SV4100 (1, 2, 3, and 4-pole; 100A) www.merkur-hamburg.de | 43 MERTRONIC - Motor Contactors and MERBREAK - MCCBs MERTRONIC - Motor Contactors and MERBREAK - MCCBs MERTRONIC power contactors are used as separation device actuated on antiislanding protection signal between photovoltaic inverter and AC utility grid. For the same purpose MERBREAK moulded case circuit breakers series EB2 assembled with motor operators enabling remote controlled operations can be used. EB2R moulded case circuit breakers with integrated residual current protection provides combined protection against overloads, short-circuits and residual currents. • CEM 9 up to CEM300 (AC3 9 up to 300A) • MERBREAK EB2 (from 20 up to 630A) • MERBREAK EB2R (from 20 up to 250A) Low Voltage Moulded Case Circuit Breakers with Residual Current Protection EB2R Breaking capacities as on MCCBs Adjustable residual current tripping thresholds between 30mA and 3A. Adjustable time delay for residual current protection between 60ms and 700ms including INST (instantaneous) and NT (No Trip). Voltage Presence LED Indicator and Trip Indicator (the yellow button pops up to indicate tripping due to residual current) Test Button (to test the residual current detection and tripping system) 44 | www.merkur-hamburg.de Type A: Tripping is ensured for residual sinusoidal AC in the presence of residual pulsating DC. Dielectric test device plug (to allow dielectric testing with the EB2R closed – ON) Adjustable overload protection Ir can be set between 63% and 100% of In MERTRONIC - Surge Arresters / NV/NH - Low Voltage Knife Blade Fuses and Disconnectors MERTRONIC - Surge Arresters MERTRONIC surge arresters protect photovoltaic system AC components against direct and indirect lightning discharges and utility grid operating overvoltages. • MERTRONIC class T1+T2: MERTRONIC B, B-F and MERTRONIC WENT • MERTRONIC class T2: MERTRONIC C NV/NH - Low Voltage Knife Blade Fuses and Disconnectors MERKUR offers a new generation of low-voltage fuse-links from size NV00C up to to NV3 with new, dual indication of fuse-link operation, called KOMBI. The indicator is easily visible on the top and centre of the fuse-link, whether it is situated in a standard fuse base or vertical fuse rail or in fuse-switch disconnector. Fuse links with gG characteristic with rated voltages 400V a.c., 500V a.c., 690V a.c. and 1000V a.c are available in versions with and without striker pin, with rated current from 2 A to 1600 A, depending on the selected product. We also offer: •NV fuse-rails sizes 00, 1, 2, 3 with accessories •NV disconnectors with fuses siyes 00, 1, 2, 3, 4a. MERKUR can also design and produce special non-standard fuse-links on customers’ request. www.merkur-hamburg.de | 45 KVS - Free-Standing Cable Distribution Cabinets KVS - Free-Standing Cable Distribution Cabinets Application: • DC collector (connecting the DC cabling for PV inverters) • AC collector (connecting the AC cabling for PV inverters) • AC cabinets • DC cabinets DC Collector 46 | www.merkur-hamburg.de AC Collector . . L1 L2 L3 N . . PE MERTRONIC B/C -1K1 -1S1 -1A1 A2 A1 14 13 11 12 14 LAS -1A1 21 22 24 TRONIC 1p -1A1 L1 L2 L3 L3 A2 L1 A1 L2 N-in N-out L2-in L2-out FREQUENCY AND VOLTAGE MONITOR TRONIC 3p L3-in L3-out ENERGY METER -1F3 -X1 MERTRONIC B/C . . . TO GRID TNC L1 L2 L3 PEN . NH HVL Enclosures TO PV PLANT -X0 . -1F1 L2 CEM 5 3 1 L1 6 4 2 -1K1 L3 L1-in L1-out kWh Enclosures www.merkur-hamburg.de | 47 L3 L1 L2 Design on Customer’s Request Design on Customer’s Request 48 | www.merkur-hamburg.de Meter Distribution Cabinet / AC Collector Meter Distribution Cabinet HVL HVL LAS CEM TRONIC 11 TRONIC 11 HRN 54 MERTRONIC C STV-D02 -1N EFI-2 STV-D02 -1N STV-D02 -1N TRONIC 6 T EFI-2 TRONIC 6 T EFI-2 MERTRONIC C T MERTRONIC C AC Collector TRONIC 6 MERTRONIC B MERTRONIC C VS www.merkur-hamburg.de | 49 Overcurrent and Overvoltage Protection for Wind Power Generation Overcurrent and Overvoltage Protection for Wind Power Generation aR / gR NH gR CH gS NH Surge Arresters VLC / PCF Disconnectors gG CH gG NH VV MV 50 | www.merkur-hamburg.de Notes www.merkur-hamburg.de MERKUR Ueberseehandel GmbH Headquarter Germany Office United Arab Emirates Office Hongkong Mattentwiete 5 20457 Hamburg Germany Level 41, Emirates Towers Sheikh Zayed Road P.O. Box: 31 303 Dubai - U.A.E. S +49 - 40 32 08 27 3 X +49 - 40 32 08 27 59 S +971 - 43 13 28 92 X +971 - 43 13 27 53 S +852 - 39 80 92 25 X +852 - 39 80 92 34 Afghanisatan Lebanon United Arab Emirates Liberty Corporation Co. 64m Street, Herat City Afghanistan S +937 - 99 69 44 81 Tele Project P.O. Box 55268 Sin el Fil Lebanon S +961 - 16 87 900 Gilco Trading LLC P.O. Box 4916 Daira, Dubai United Arab Emirates S +971 - 43 96 15 25 Oman Yemen Trade Links and Services Co. LLC P.O.Box 2901 Ruwi 112 Sultanate of Oman S +968 - 24 70 67 75 Al Ashwal for Elecrical Trade & Agencies Shoub Street Sana’a Yemen Republic S +967 - 12 82 43 2 Unit 1202, Level 12, One Peking Building 1 Peking Road, Tsim Sha Tsui Hongkong U mail@merkur-hamburg.de Distributors Bahrain Shaheen Group P.O.Box 405 Manama Kingdom of Bahrain S +973 -17 81 35 35z Cameroon Saudi Arabia CALICO Sarl BP 15566 Douala Cameroon S +237- 22 43 80 44 Ahmed Omer Bagazy Est. P.O. Box 16367 Jeddah 21464 Saudi Arabia S +966 - 26 47 29 28 Ghana Sri Lanka Luminant Electricals P.O. Box CT5204 Cantonment-Accra Ghana S +233 - 27 52 29 62 2 Rotax Limited 332 Galle Road Colombo 04 Sri Lanka S +94 - 11 55 74 07 0 R ®
Similar documents
CIMCO CJENIK 2016 (kn) - Daljinsko Upravljanje doo
WATER PUMP PLIERS DIN5231D,175 WATER PUMP PLIER DIN5231D,245 WATER PUMP PLIER DIN5231D, 315 WATER PUMP PLIER POWER GRIP WATER PUMP PLIER POWER GRIP WATER PUMP PLIER POWER GRIP DRAIN TAP PLIER PIPE ...
More informationAccessories
Description - UPO covering consists of terminal plates that should be fixed on mounting rails, and flat and corner profiles, which are click-on mounted on the terminal plates. The space between row...
More information