Outdoor Housing

Transcription

Outdoor Housing
Outdoor Housing
PIH-510 H/L/G & 510 H/L/G IP
MERIT LILIN ENT. CO., LTD
http://www.meritlilin.com
66-510CSE
INSTRUCTION MANUAL
IMPORTANT SAFEGUARDS
1. Read Instructions
All the safety and operating instructions should be read before the unit is operated.
2. Retain Instructions
The safety and operating instructions should be retained for future reference.
3. Head Warnings
All warnings on the unit and in the operating instructions should be adhered to.
4. Follow Instructions
All operating and user instructions should be followed.
5. Electrical Connections
Only a qualified electrician should make electrical connections.
6. Attachments
Do not use attachments not recommended by the product manufacturer as they may cause hazards.
7. Cable Runs
All cable runs must be within permissible distance.
8. Mounting
This unit must be properly and securely mounted to a supporting structure capable of sustaining the weight
of the unit.
SAFETY PRECAUTIONS
CAUTION
RISK OF ELECTRIC SHOCK
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT OPEN COVER.
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated "dangerous voltage" within the
product's enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in
the literature accompanying the unit.
UNPACKING
Unpack carefully. Electronic components can be damaged if improperly handled or dropped. If an item appears
to have been damaged in shipment, replace it properly in its carton and notify the shipper.
Be sure to save:
1. The shipping carton and packaging material. They are the safest material in which to make future shipments
of the equipment.
2. This Installation and Operating Instruction.
SERVICE
If the unit ever needs repair service, the customer should contact our dealer or branch for authorization to
return and shipping instructions.
INSTALLATION
Step 1
Separate The Housing and PSU Box
Untighten the screws
from PSU box
Step 2
Untighten and pull out Separate the housing
the bolt from the hinge and PSU box
Untighten the screws
from PSU box and
open it. (Swan Neck)
Install Power Supply Unit
When use 24Vac power source:
Tighten 2 screws to
fix the PSU
Put the PSU into the
box
When use 90~260Vac power source:
Put PSU into the box
Put the clamp on PSU
1
Tighten 2 screws to
fix the PSU
Step 3
Install the Power Box
8
10
45
70
50.8
70
Drill 4 holes on desired
locations
Step 4
Tighten 4 screws to fix the power box
(These four screws are not supplied.
User must prepare their own screws.)
50.8
Drill holes on the
intended positions of
of the wall.
(Goose Neck)
Connection
Outdoor Housing Connection
RS-485 Alarm In
Alarm Output
GND
NO
NC
COM
6
5
4
3
2
1
GND
TXDOTXDO+
TXDITXDI+
DC12V Input
VideoOutput
Fan&Heater FastDome
Wiring
Wiring
ACOutput
ACInput
1. Connect AC / DC cables:
Untighten the left
knob, put the AC
power cable through
the hole and tighten
the knob
Connect the AC
power cable to AC
Input jack
Connect the AC
power cable(below)
to AC Output jack
2
Connect the DC
power cable(above)
to DC Input jack
2. Connect Video cable:
Connect the video
cable to output jack
Untighten the middle
knob, put the video
cable through the hole
and tighten the knob
3. Connect Alarm, telemetry control (RS-485) and Video cables:
Untighten the right
knob, put the Alarm
and RS-485 cables
through the hole and
tighten the knob
Connect the
telemetry control
(RS-485) to RS-485
Input
(TXDI+,TXDI-)
Connect the Alarm
input cable to Alarm
Input
(Alarm 1 & GND)
CAUTION
* For better waterproofing, please use one cable with one knob only.
(Recommended)
* When using two cables with one knob, please fill the seam between
cables with waterproof glu to make it waterproof.
Cable diameter for the knob : 5~12mm
3
Outdoor Housing for IP Series Connection
RS-485
Alarm In Alarm Output
GND
NO
NC
COM
6
5
4
3
2
1
GND
TXDOTXDO+
TXDITXDI+
RJ-45
DC12V Input
VideoOutput
Fan&Heater
Wiring
FastDomeWiring
ACOutput
ACInput
1. Connect AC / DC cables:
Untighten the left
knob, put the AC
power cable through
the hole and tighten
the knob
Connect the AC
power cable to AC
Input jack
Connect the AC
power cable(below)
to AC Output jack
Connect the DC
power cable(above)
to DC Input jack
2. Connect RJ-45 and Video cables:
Untighten the middle
knob, put the video
and RJ-45 cables
through the hole and
tighten the knob
Connect the video
cable to output jack
4
Connect the network
cable to RJ-45 jack
3. Connect Alarm, RS-485, cables:
Untighten the right knob,
put the Alarm and RS-485
cables through the hole
and tighten the knob
Connect the telemetry
control (RS-485) to RS-485
Input (TXDI+,TXDI-)
Connect the Alarm input
cable to Alarm Input
(Alarm 1 & GND)
CAUTION
* For better waterproofing, please use one cable with one knob only.
(Recommended)
* When using two cables with one knob, please fill the seam between
cables with waterproof glu to make it waterproof.
Cable diameter for the knob : 5~12mm
Step 5
Attach the Base to Housing
Turn the dome cover
anti-clockwise
Separate the dome
cover from camera
5
Untighten the 3
screws from base
Turn the camera body
anti-clockwise
Separate the camera
body and base
Unplug the
connection cable
Attach the base to
housing
Connect the housing
cable
Tighten 3 screws to
fix base
Step 6
Camera Setting
Setting Fast Dome ID
Setting Alarm Mode
Setting Camera Function
Setting Fan Power
Refer to FastDome operation manual for camera setting
Step 7
Attach Camera Body and Base
Reconnect the
connection cable
Attach camera body
to base
Turn camera body
clockwise to high
position
6
Tighten the three
screws to fix the
camera body
Step 8
Install The Dome Cover and Housing Cover
Attach the dome
cover to camera
Step 9
Turn the dome cover
clockwise to tight
position
Attach the cover to
housing
Tighten the 3 screws
to fix the cover
Attach PSU and Bracket
Attach the housing
back to PSU box
Insert the bolt into
the hinge and tighten
Step 10 Connection Between Housing and FastDome
Connect the fan &
heater cable to pin
jack
Connect the Fast
Dome cable to
connection jack
7
Step 11
Install the Power Box, Bracket and Housing
Pendant
Attach the bracket
and housing to the box
Tighten the 4 screws
to fix the bracket
Wall Mounting
Attach the bracket
and housing to the box
Tighten the 4 screws
to fix the bracket
Swan Neck
Tighten the screws of
PSU box to fix the cover.
8
STRUCTURAL DRAWING
Wall Mounting
Pendant
274
70
70
204
477.5
367.2
312.5
270
270
405
Swan Neck
500
225
320
650
270
200
685
Unit: MM
9
WIRING DIAGRAM
Outdoor Housing
Connect to
Heater and Fan
DC12V
OUT
SWITCH POWER
AC90~260V
or
SWITCH POWER
AC24V
TXDI+
TXDITXDO+
TXDOGND
Connect to
FastDome
LINE
NEUTRAL
DC12V
IN
ALARM
IN
GND
AC-OUT
GND
ALARM
OUT
NEUTRAL
1
2
3
4
5
6
COM
NC
NO
GND
LINE
NEUTRAL
GND
LINE
AC-IN
AC24V
AC-IN
24Vac
VIDEO
OUT
TO
NEXT
FastDome
TO
Keyboard
Outdoor Housing for IP Series
Connect to
Heater and Fan
DC12V
OUT
SWITCH POWER
AC24V
Connect to
FastDome
LINE
NEUTRAL
TXDI+
TXDITXDO+
TXDOGND
ALARM
IN
GND
AC-OUT
GND
ALARM
OUT
NEUTRAL
1
2
3
4
5
6
COM
NC
NO
GND
LINE
LINE
NEUTRAL
or
GND
SWITCH POWER
AC90~260V
DC12V
IN
TO IP
AC-IN
AC24V
AC-IN
24Vac
10
VIDEO
OUT
TO
TO
NEXT
FastDome Keyboard
SPECIFICATION
Outdoor Housing
Model No.
Type
PIH-510 L
PIH-510 G
PIH-510 H
Pendant
Wall Mounting Swan Neck
Brocket
Aluminum
Top
Flame Resistant ABS
Construction
Internal Fixing
Steel
Housing
Polycarbonate
Input Voltage
DC12V
Connection Current Consumption 700mA (Fan + Heater)
PCB
RS-485
RS-485 In (2 inputs) RS-485 Out (2 outputs)
Alarm
Alarm-In (6 inputs) Alarm-Out (3 outputs)
On +15 C
OFF +25 C
Heater Activation
Fan Activation
On +35 C
OFF +25 C
270mm( f ) x 297.5mm(H)
Dimension
Weight
5Kg
4.8Kg
10Kg
Outdoor Housing for IP Series
PIH-510 G
PIH-510 L
PIH-510 H
Pendant
Wall Mounting Swan Neck
Brocket
Aluminum
Top
Flame Resistant ABS
Construction
Internal Fixing
Steel
Housing
Polycarbonate
Input Voltage
DC12V
Current Consumption 700mA (Fan + Heater)
Connection
RS-485
RS-485 In (2 inputs) RS-485 Out (2 outputs)
PCB
RJ-45
One RJ-45 for Ethernet (10 Base-T)
Alarm
Alarm-In (6 inputs) Alarm-Out (3 outputs)
On +15 C
OFF +25 C
Heater Activation
Fan Activation
On +35 C
OFF +25 C
270mm( f ) x 297.5mm(H)
Dimension
Weight
10Kg
5Kg
4.8Kg
Model No.
Type
11
66-510CSE-5
Outdoor Housing
PIH-510 H/L//G & 510 H/L/G IP
MERIT LILIN ENT. CO., LTD
http://www.meritlilin.com
66-510CSE
INSTRUCTION MANUAL