SENTRIC Switch Disconnectors and Fuse Switch Disconnectors
Transcription
SENTRIC Switch Disconnectors and Fuse Switch Disconnectors
SENTRIC Switch Disconnectors and Fuse Switch Disconnectors 6/2 Introduction SENTRIC switch disconnectors 6/4 6/7 6/11 6/13 6/15 6/17 6/19 SENTRIC LD main control and EMERGENCY-STOP switches from 16 A to 125 A General data Front mounting Base mounting Distribution board mounting Molded-plastic enclosure Accessories Project planning aids 6/26 6/31 6/34 6/35 6/37 SENTRIC K switch disconnectors from 63 A to 1000 A General data Base mounting Molded-plastic enclosure Accessories Project planning aids 6/57 SENTRIC NP fuse switch disconnectors General data For power distribution Accessories for power distribution For high technical requirements Accessories for high technical requirements Project planning aids 6/65 6/68 6/70 6/71 6/72 6/74 SENTRIC KL and 3KM switch disconnectors with fuses General data Surface and flush mounting Front mounting For plugging into busbar system Accessories Project planning aids 6/40 6/46 6/48 6/51 6/55 6/79 6/81 6/82 6/84 SENTRIC NJ in-line fuse switch disconnectors General data 1-pole switchable, 3-pole switchable Accessories Project planning aids 6/87 Plug-in in-line switch disconnectors with fuses up to 630 A 6/88 SITOR semiconductor protection fuses For semiconductor protection LV HRC fuses see Section 2 "BETA protect modular installation devices" Siemens LV 30 · 2004 SENTRIC Switch Disconnectors and Fuse Switch Disconnectors Introduction ■ Overview Type 3LD20 3LD21 3LD22 3LD25 3LD27 3LD28 SENTRIC LD main control and EMERGENCY-STOP switches from 16 A to 125 A 6 Rated uninterrupted current IU at 35 °C ambient temperature A 16 25 32 63 100 125 Rated operating voltage Ue V 690 690 690 690 690 690 AC-3 motor load switch Operational switching of individual motors at 220 ... 240 V kW at 380–440 V kW at 660/690 V kW 3.0 5.5 5.5 4.0 7.5 7.5 5.5 9.5 9.5 11.0 18.5 15.0 18.5 30.0 22.0 22.0 37.0 30.0 AC-23A main control switch, maintenance switch frequent, but not operational switching of single motors at 220 ... 240 V kW at 380 ... 440 V kW at 660/690 V kW 4.0 7.5 7.5 5.0 9.5 9.5 6.0 11.5 11.5 11.0 22.0 18.5 18.5 37.0 30.0 22.0 45.0 37.0 • Central • Four-hole ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ – ✓ – ✓ Base mounting • Central • Four-hole ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ – – ✓ – – ✓ Distribution board mounting ✓ ✓ ✓ ✓ ✓ ✓ Insulated enclosure • Heavy-gauge threaded joint • Metric screwed gland ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N terminal PE/ground terminal ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Auxiliary contacts 1 NO + 1 NC 1 NO 1 NC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Switch versions Front mounting Switch accessories 4th pole (neutral conductor) (leading switch-on, delayed switch-off) 6/2 ¸ Siemens LV 30 · 2004 SENTRIC Switch Disconnectors and Fuse Switch Disconnectors Introduction Type 3NP 3K 3NJ4 SENTRIC Rated uninterrupted current IU at 35 °C ambient temperature A 160 ... 630 63 ... 1000 160 ... 1250 Rated operating voltage Ue V 690 690 690 AC-21 at 400 V at 500 V at 690 V ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ AC-22 at 400 V at 500 V at 690 V ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ AC-23 at 400 V at 500 V at 690 V ✓ – – ✓ ✓ ✓ – – – 6 Switch versions Front mounting – ✓ – Base mounting ✓ ✓ – Busbars • 40 mm • 60 mm • 185 mm ✓ ✓ – – ✓ – – – ✓ Insulated enclosure ✓ ✓ – – ✓ – Auxiliary contacts 1 NO + 1 NC 1 C/O – ✓ ✓ ✓ – ✓ Fuse monitoring • with circuit-breakers • with electronics ✓ ✓ ✓ ✓ ✓ ✓ Switch accessories 4th pole (neutral conductor) (leading switch-on, delayed switch-off) Siemens LV 30 · 2004 6/3 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A General data ■ Overview , ( $ & + ( 6 % * & ) $ Fourth contact element (neutral conductor) % N or PE/ground terminal, continuous & Auxiliary switch, 1 NO or 1 NC ( Auxiliary switch, 1 NO and 1 NC ) Rotary operating mechanism, red/yellow * Rotary operating mechanism, black + Front plate, German/English , Terminal cover, three-pole - Terminal cover, one-pole 6/4 Siemens LV 30 · 2004 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A General data ■ Area of application The SENTRIC LD switches are used for switching main and auxiliary circuits, but also for switching induction motors and other loads during maintenance and repair work. They are manually operated switch disconnectors according to IEC 60947-3/VDE 0660 Part 107 (EN 60947-3) and fulfill the conditions for switch disconnectors. The SENTRIC LD switches can be used as • On-Off switches • EMERGENCY-STOP switches • Main control switches to EN 60204-1 In EN 60204-1 (VDE 0113 Part 1), main control switches are called "mains isolating devices", while EMERGENCY-STOP switches are termed "devices for emergency shutdowns". Maintenance personnel can protect themselves against unauthorized startup with padlocks (up to three can be fitted). ■ Design Switches for distribution board mounting The switches for distribution board mounting are suited for use in switchboards and for switching inside control cabinets or distributors. They have cap and fitting dimensions to DIN 43880 and can be fitted under the same cover together with miniature circuit-breakers. The selector switches can be locked in their Off position with up to 2 padlocks with a hasp thickness of 6 mm. Switches in molded-plastic enclosure For surface mounting of individual main control and EMERGENCY-STOP switches, molded plastic-enclosed switches to degree of protection IP 65 are used. The operating elements can be locked in their Off position with three padlocks with a hasp thickness of 8 mm. The molded-plastic enclosures each contain an N and/or a PE/ground terminal. 1) 16 A versions have four contact elements; 3-pole changeover switches and 6-pole main control switches have six contact elements. 3LD2 203–0TK5 switch for front mounting with rotary operating mechanism 3LD2 222–0TK1 switch for front mounting with selector switch 3LD2 122–7UK01 3-pole changeover switch for front mounting with selector switch 3LD2 103–3VK53 6-pole switch for front mounting with rotary operating mechanism 3LD2 213–0TK5 switch for base mounting with rotary operating mechanism and door coupling 3LD2 530–0TK11 switch for distribution board mounting with selector switch Construction of the contacts Each switch has three adjacent contact elements1). A fourth leading switching element for switching the neutral conductor, a continuous PE/ground terminal, an auxiliary switch (1 NO or 1 NC or 1 changeover contact) can be fitted to each side of the switch. The auxiliary switches operate as leading contacts on opening. On opening, the make contact opens before the main contacts, so that a contactor carries the switching duty in the circuit and the service or safety switch switches at zero current. On closing, the auxiliary switch switches later than or at the same time as the main contacts. Switch construction Construction of rotary operating mechanisms The rotary mechanisms of the switches for front or base mounting are mounted on control panel doors, front panels or side walls with four-hole or center-hole mounting with a standard diameter of 22.5 mm and operated from the outside. In their Off position, they can be locked with up to three padlocks with a hasp thickness of 8 mm. Switch position indication The switch position is clearly marked with direction arrows and an "O" for OFF and a "I" for ON at the front. Switches for front mounting The switches for front mounting are connected directly to the rotary operating mechanism through the fixing screws or – in the case of center-hole mounting – a special-purpose coupling. Switches for base mounting The switches for base mounting are snapped onto 35 mm mounting rails to EN 50022 or screw-mounted on mounting plates. The actuators are connected to the lower section of the switch through a door coupling, which can be released in its zero position, and a 300 mm long switch shaft. When the control cabinet door is open, the switch can be protected against inadvertent operation by removing the switch shaft from the lower section of the switch. 3LD2 261-0TB5 switch in molded-plastic enclosure The mounting depth can be adapted to individual requirements by adjusting the switch shaft length. Siemens LV 30 · 2004 6/5 6 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A General data ■ Technical specifications Specifications DIN VDE 0660, IEC 60 947 Switch Type Number of contacts 3LD2 1 3LD2 2 3LD2 5 3LD2 7 3LD2 8 3/4 3/4 3/4 3/4 3/4 3/4 Rated insulation voltage Ui Rated operating voltage Ue Rated frequency Rated impulse withstand voltage Uimp V AC V Hz kV 690 690 50 ... 60 6 690 690 50 ... 60 6 690 690 50 ... 60 6 Rated short-time withstand current (1 s current, r.m.s. value) Short-circuit protection, max. back-up fuse (gL) A A 340 20 640 25 640 50 1260 63 2000 100 2000 125 Rated uninterrupted current Iu 690 690 50 ... 60 6 690 690 50 ... 60 6 690 690 50 ... 60 6 A 16 25 32 63 100 125 AC-21A load-break switch Rated operating current Ie A 16 25 32 63 100 125 AC-3 motor load switch In-service switching of individual motors Rating at 220 V ... 240 V at 380 V ... 440 V at 660 V/690 V kW kW kW 3.0 5.5 5.5 4.0 7.5 7.5 5.5 9.5 9.5 11.0 18.5 15.0 18.5 30.0 22.0 22.0 37.0 30.0 AC-23A main control switch Maintenance switch frequent, but not in-service switching of individual motors Rating at 220 V ... 240 V at 380 V ... 440 V at 660 V/690 V kW kW kW 4.0 7.5 7.5 5.0 9.5 9.5 6.0 11.5 11.5 11.0 22.0 18.5 18.5 37.0 30.0 22.0 45.0 37.0 W Power loss per conducting path at Ie Touch protection to DIN VDE 0106 Part 100 6 3LD2 0 0.5 1.1 1.8 4.5 7.5 12 yes yes yes yes yes yes 100 000 100 000 100 000 100 000 100 000 Endurance mechanical Oper. 100 000 cycles Max. frequency of operation 1/h 50 50 50 50 50 50 Permissible ambient temperature °C –25 ... +55 –25 ... +55 –25 ... +55 –25 ... +55 –25 ... +55 –25 ... +55 Isolating characteristics up to ... V 690 690 690 690 690 690 yes yes yes yes yes yes Characteristics of main control and EMERGENCY-STOP switches Conductor cross-sections for main conductors Connection type Solid or stranded Flexible with end sleeve (max.) 1) mm2 mm2 Terminal clamps 1–6 1.5–16 4 10 1.5–16 10 2.5–35 16 4–50 35 4–50 35 V AC V A A A A A 500 500 10 6 3 1.8 1.4 500 500 10 6 3 1.8 1.4 500 500 10 6 3 1.8 1.4 500 500 10 6 3 1.8 1.4 500 500 10 6 3 1.8 1.4 500 500 10 6 3 1.8 1.4 10 10 10 10 10 10 2× (0.75 ... 4) 1× (0.75 ... 4) 2× (0.75 ... 4) 1× (0.75 ... 4) 2× (0.75 ... 4) 1× (0.75 ... 4) 2× (0.75 ... 4) 1× (0.75 ... 4) Auxiliary switches Rated insulation voltage Ui Rated operating voltage Ue Rated uninterrupted current Iu Rated operating current Ie AC-15 at 120 V at 220 V ... 240 V at 380 V ... 415 V at 500 V Short-circuit protection, auxiliary switch, max. back-up fuse (gL/gG) A Conductor cross-sections for auxiliary conductors Connection type Solid or stranded mm2 2 Finely stranded with end sleeve mm Specifications Terminal clamps 2× 2× (0.75 ... 4) (0.75 ... 4) 1× 1× (0.75 ... 4 (0.75 ... 4) UL/CSA Switch Type 3LD2 0 3LD2 1 3LD2 2 3LD2 5 3LD2 7 3LD2 8 Rated operating voltage Ue Rated uninterrupted current Iu AC V A 600 20 600 A P600 25 600 30 600 A P600 32 600 60 – 600 100 – 600 125 – A 600 10 600 A P600 16 63 100 125 3 ∼ 120 V 240 V 480 V 600 V HP HP HP HP 1 3 7.5 10 – 7.5 10 15 – 10 20 30 – 15 40 50 – 30 60 75 – 40 75 100 1 ∼ 120 V 240 V HP HP 0.5 1.5 2 3 2 3 – 10 – – – – Current rating Pilot duty Continuous thermal current Ith Max. rating (AC-3) Single-phase AC motors 40 Hz ... 60 Hz Conductor cross-sections Torque Cu cable AWG Nm 1) With appropriate DIN VDE 0113 conformant operating mechanisms (see Selection and ordering data). 6/6 Siemens LV 30 · 2004 18–10 1.5–2 14–8 2–2.5 14–8 2–2.5 14–6 2.5–3 12–1 2.5–3 12–1 2.5–3 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Front mounting ■ Area of application The SENTRIC 3LD2 switches are used for switching main and auxiliary circuits, but also for switching induction motors and other consumers during maintenance and repair work. They can be used as • On-Off switches, • EMERGENCY-STOP switches • Main control switches to EN 60204-1. Main control and EMERGENCY-STOP switches are manually operated switch disconnectors according to IEC 60947-3/ VDE 0660 Part 107 (EN 60947-3) and fulfill the conditions for switch disconnectors and the requirements of the machinery directive EN 60204-1. ■ Selection and ordering data Number and version Rated data of contacts at 50 Hz ... 60 Hz 380 V ... 440 V Main Auxiliary P/ contact contact AC-23A elements elements kW DT PS* Four-hole mounting Weight per PU approx. DT PS* Center-hole mounting Ø 22.5 mm Weight per PU approx. Iu A Order No. kg Order No. kg 1 Main control and EMERGENCY-STOP switches with rotary operating mechanism ) • Lockable in 0 position with up to 3 padlocks • Degree of protection at front IP65 • Front plate – 3LD2 0, 3LD2 1, 3LD2 2: 67 mm × 67 mm – 3LD2 5 to 3LD2 8: 90 mm × 90 mm. 3 – 16 25 32 } } } 3LD2 003–0TK.. 3LD2 103–0TK.. 3LD2 203–0TK.. 1 unit 1 unit 1 unit 0.207 A 0.206 A 0.206 A 3LD2 054–0TK.. 3LD2 154–0TK.. 3LD2 254–0TK.. 1 unit 1 unit 1 unit 0.215 0.215 0.214 63 100 125 } } A 3LD2 504–0TK.. 3LD2 704–0TK.. 3LD2 804–0TK.. 1 unit 1 unit 1 unit 0.424 A 0.501 0.503 3LD2 555–0TK.. – – 1 unit 0.443 7.5 9.5 11.5 16 25 32 } A A 3LD2 003–1TL.. 3LD2 103–1TL.. 3LD2 203–1TL.. 1 unit 1 unit 1 unit 0.217 A 0.243 A 0.243 A 3LD2 054–1TL.. 3LD2 154–1TL.. 3LD2 254–1TL.. 1 unit 1 unit 1 unit 0.230 0.256 0.260 22 63 } 3LD2 504–0TK.. +2) 3LD9 250–0B 1 unit 0.424 A 1 unit 0.443 1 unit 0.079 } 3LD2 555–0TK.. +2) 3LD9 250–0B 1 unit 0.079 37 100 3LD2 704–0TK.. +2) 3LD9 280–0B 1 unit 0.501 – 1 unit 0.101 45 125 3LD2 804–0TK.. +2) 3LD9 280–0B 1 unit 0.503 1 unit 0.101 7.5 9.5 11.5 22 37 45 3LD2 203-0TK53 3+N – } } } A } Actuator black red/yellow (EMERGENCY-STOP) > 51 53 – > 51 53 1) A terminal cover for the supply side is included in the scope of supply. 2) Please order 4th contact element as neutral conductor separately, see Accessories. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/7 6 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Front mounting Number and version Rated data of contacts at 50 Hz ... 60 Hz 380 V ... 440 V Main Auxiliary P/ contact contact AC-23A elements elements kW DT PS* Four-hole mounting Weight per PU approx. DT PS* Center-hole mounting Ø 22.5 mm Weight per PU approx. Iu A Order No. kg Order No. kg Main control and EMERGENCY-STOP switches with rotary operating mechanism1) • Lockable in 0 position with up to 3 padlocks • Degree of protection at front IP65 • Front plate – 3LD2 0, 3LD2 1, 3LD2 2: 67 mm × 67 mm – 3LD2 5 to 3LD2 8: 90 mm × 90 mm. 3 1 NO + 1 NC 7.5 16 A 3LD2 003–1TP.. 1 unit 0.250 A 3LD2 054–1TP.. 1 unit 0.261 9.5 25 A 3LD2 103–1TP.. 1 unit 0.249 A 3LD2 154–1TP.. 1 unit 0.257 11.5 32 } 3LD2 203–0TK.. +3) 3LD9 220–5B 1 unit 0.206 A 1 unit 0.214 1 unit 0.046 } 3LD2 254–0TK.. +3) 3LD9 220–5B 1 unit 0.046 22 63 3LD2 504–0TK.. +3) 3LD9 250–5B 1 unit 0.424 A 1 unit 0.443 1 unit 0.047 A 3LD2 555–0TK.. +3) 3LD9 250–5B 1 unit 0.047 37 100 3LD2 704–0TK.. +3) 3LD9 280–5B 1 unit 0.501 – 1 unit 0.047 45 125 1 unit 0.503 A 3LD2 804–0TK.. +3) 3LD9 280–5B 1 unit 0.047 } 3LD2 203-0TK53 } A } A 6 3+N 1 NO + 1 NC A – 7.5 16 A 3LD2 003–2EP.. 1 unit 0.272 A 3LD2 054–2EP.. 1 unit 0.276 9.5 25 A 3LD2 103–2EP.. 1 unit 0.287 C 3LD2 154–2EP.. 1 unit 0.304 11.5 32 A 3LD2 203–1TL.. +2) 3LD9 220–5B 1 unit 0.243 A 1 unit 0.260 1 unit 0.046 } 3LD2 254–1TL.. +2) 3LD9 220-5B 1 unit 0.046 22 63 3LD2 504–0TK.. +3) 3LD9 250–0B +2) 3LD9 250–5B 1 unit 0.424 A 1 unit 0.443 1 unit 0.079 } 1 unit 0.079 1 unit 0.047 A 3LD2 555–0TK.. +3) 3LD9 250–0B +2) 3LD9 250–5B 1 unit 0.047 3LD2 704–0TK.. +3) 3LD9 280–0B +2) 3LD9 250–5B 1 unit 0.501 – 1 unit 0.101 1 unit 0.047 } } } A 37 100 } } A 45 125 } A 3LD2 804–0TK.. +3) 3LD9 250–0B +2) 3LD9 280–5B Actuator black red/yellow (EMERGENCY-STOP) > 51 53 – 1 unit 0.079 1 unit 0.047 > 51 53 1) A terminal cover for the supply side is included in the scope of supply. 2) Please order auxiliary switches 1 NO + 1 NC separately, see Accessories. 3) Please order 4th contact element as neutral conductor separately, see Accessories. 6/8 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Front mounting Number and version Rated data of contacts at 50 Hz ... 60 Hz 380 V ... 440 V Main Auxiliary P/ contact contact AC-23A elements elements kW DT PS* Four-hole mounting Weight per PU approx. DT PS* Center-hole mounting Ø 22.5 mm Weight per PU approx. Iu A Order No. kg Order No. kg Main control and EMERGENCY-STOP switches with selector switch operating mechanism1) • Lockable in 0 position (can be modified to I position) with up to 2 padlocks • Degree of protection at front IP65 • Front plate – 48 mm × 48 mm. 3 3+N – – 7.5 16 A 3LD2 022–0TK.. 1 unit 0.186 A 3LD2 050–0TK.. 1 unit 0.197 9.5 25 A 3LD2 122–0TK.. 1 unit 0.181 A 3LD2 150–0TK.. 1 unit 0.191 11.5 32 A 3LD2 222–0TK.. 1 unit 0.182 A 3LD2 250–0TK.. 1 unit 0.192 7.5 16 A 3LD2 022–1TL.. 1 unit 0.206 A 3LD2 050–1TL.. 1 unit 0.215 9.5 25 A 3LD2 122–0TK.. +2) 3LD9 220–0B 1 unit 0.181 A 1 unit 0.191 1 unit 0.039 } 3LD2 150–0TK.. +2) 3LD9 220–0B 1 unit 0.039 11.5 32 A 3LD2 222–0TK.. +2) 3LD9 220–0B 1 unit 0.182 A 1 unit 0.192 1 unit 0.039 } 3LD2 250–0TK.. +2) 3LD9 220–0B 1 unit 0.039 7.5 16 A 3LD2 022–0TK.. +3) 3LD9 220–5B 1 unit 0.186 A 1 unit 0.197 1 unit 0.046 } 3LD2 050–0TK.. +3) 3LD9 220–5B 1 unit 0.046 9.5 25 3LD2 122–0TK.. +3) 3LD9 220–5B 1 unit 0.181 A 1 unit 0.191 1 unit 0.046 } 3LD2 150–0TK.. +3) 3LD9 220–5B 1 unit 0.046 3LD2 222–0TK.. +3) 3LD9 220–5B 1 unit 0.182 1 unit 0.192 1 unit 0.046 } 3LD2 250–0TK.. +3) 3LD9 220–5B 1 unit 0.046 3LD2 022–1TL.. +3) 3LD9 220–5B 1 unit 0.206 A 1 unit 0.215 1 unit 0.046 } 3LD2 050–1TL.. +3) 3LD9 220–5B 1 unit 0.046 3LD2 122–0TK.. +1) 3LD9 220–0B +3) 3LD9 220–5B 1 unit 0.181 A 1 unit 0.191 1 unit 0.039 } 1 unit 0.039 1 unit 0.046 } 3LD2 150–0TK.. +1) 3LD9 220–0B +3) 3LD9 220–5B 1 unit 0.046 3LD2 222–0TK.. +1) 3LD9 220–0B +3) 3LD9 220–5B 1 unit 0.182 A 1 unit 0.192 1 unit 0.039 } 1 unit 0.039 1 unit 0.046 } 3LD2 250–0TK.. +1) 3LD9 220–0B +3) 3LD9 220–5B 1 unit 0.046 3LD2 222-0TK11 } } 3 1 NO + 1 NC } A } 11.5 32 A 7.5 16 A 9.5 25 } 3+N 1 NO + 1 NC } A } } 11.5 32 A } } Actuator black red/yellow (EMERGENCY-STOP) > 11 13 > 11 13 1) A terminal cover for the supply side is included in the scope of supply. 2) Please order 4th contact element as neutral conductor separately, see Accessories. 3) Please order auxiliary switches 1 NO + 1 NC separately; see Accessories. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/9 6 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Front mounting Number and version Rated data of contacts at 50 Hz ... 60 Hz 380 V ... 440 V Main Auxiliary P/ P/ contact contact AC-3 ACelements elements 23A kW kW PS* DT Weight per PU approx. Iu A Order No. kg Main control and EMERGENCY-STOP switches with rotary operating mechanism • Degree of protection at front IP65 6 3LD2 103-3VK53 6 – 1 NO + 1 NC 7.5 9.5 25 A 3LD2 103–3VK.. 1 unit 0.380 9.5 11.5 32 A 3LD2 203–3VK.. 1 unit 0.381 18.5 22.0 63 A 3LD2 504–3VK.. 1 unit 0.854 7.5 9.5 25 A 3LD2 103–4VP.. 1 unit 0.432 Number and version Rated data of contacts at 50 Hz ... 60 Hz 380 V ... 440 V Main Auxiliary P/ P/ contact contact AC-3 ACelements elements 23A kW kW PS* DT Weight per PU approx. Iu A Order No. kg Changeover switch with selector switch operating mechanism, selector switch not lockable • Black actuator, degree of protection at front IP65 3 6 – 3LD2 123-7UK01 7.5 9.5 25 A 3LD2 123–7UK01 1 unit 0.374 9.5 11.5 32 A 3LD2 223–7UK01 1 unit 0.378 18.5 22.0 63 A 3LD2 524–7UK01 1 unit 0.841 30.0 37.0 100 A 3LD2 724–7UK01 1 unit 1.060 > 51 Actuator black red/yellow (EMERGENCY-STOP) 53 Number and version Rated data of contacts at 50 Hz ... 60 Hz 380 V ... 440 V Main Auxiliary P/ P/ contact contact AC-3 ACelements elements 23A kW kW PS* DT Weight per PU approx. Iu A Order No. kg Main control and EMERGENCY-STOP switches with selector switch operating mechanism • Four-hole mounting • Degree of protection at front IP65 6 – Actuator black red/yellow (EMERGENCY-STOP) 6/10 Siemens LV 30 · 2004 9.5 9.5 25 A 3LD2 122–3VK.. 1 unit 0.378 > 11 13 * This quantity or a multiple thereof can be ordered. SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Base mounting Number and version Rated data of contacts at 50 Hz ... 60 Hz 380 V ... 440 V Main Auxiliary P/ contact contact AC-23A elements elements kW DT PS* Four-hole mounting Weight per PU approx. DT PS* Center-hole mounting Ø 22.5 mm Weight per PU approx. Iu A Order No. kg Order No. kg Main control and EMERGENCY-STOP switches with door-coupling rotary operating mechanism 1)2) • With 300 mm switch shaft • Lockable in 0 position with up to 3 padlocks • Degree of protection at front IP65 • Front plate – 3LD2 0, 3LD2 1, 3LD2 2: 67 mm × 67 mm – 3LD2 5 to 3LD2 8: 90 mm × 90 mm. 3 – 16 25 32 } } } 3LD2 013–0TK.. 3LD2 113–0TK.. 3LD2 213–0TK.. 1 unit 1 unit 1 unit 0.412 A 0.407 A 0.405 A 3LD2 044–0TK.. 3LD2 144–0TK.. 3LD2 244–0TK.. 1 unit 1 unit 1 unit 0.430 0.426 0.427 63 100 125 } } A 3LD2 514–0TK.. 3LD2 714–0TK.. 3LD2 814–0TK.. 1 unit 1 unit 1 unit 0.655 A 0.765 0.766 3LD2 545–0TK.. – – 1 unit 0.710 7.5 9.5 11.5 16 25 32 } A } 3LD2 013–1TL.. 3LD2 113–1TL.. 3LD2 213–0TK.. +3) 3LD9 220–0C 1 unit 1 unit 1 unit 0.412 A 0.450 A 0.405 A 1 unit 1 unit 1 unit 0.433 0.461 0.427 1 unit 0.039 } 3LD2 044–1TL.. 3LD2 144–1TL.. 3LD2 244–0TK.. +3) 3LD9 220–0C 1 unit 0.039 22 63 3LD2 514–0TK.. +3) 3LD9 250–0C 1 unit 0.655 A 1 unit 0.710 1 unit 0.080 } 3LD2 545–0TK.. +3) 3LD9 250–0C 1 unit 0.080 37 100 3LD2 714–0TK.. +3) 3LD9 280–0C 1 unit 0.765 – 1 unit 0.102 3LD2 814–0TK.. +3) 3LD9 280–0C 1 unit 0.766 1 unit 0.102 7.5 9.5 11.5 22 37 45 3+N – } 3LD2 213-0TK53 } } } } 45 125 A } Actuator black red/yellow (EMERGENCY-STOP) > 51 53 – > 51 53 1) Mounting using screws or snap-on mounting on 35 mm standard mounting rail is standard. 2) A terminal cover for the supply side is included in the scope of supply. 3) Please order 4th contact element as neutral conductor separately, see Accessories. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/11 6 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Base mounting Number and version Rated data of contacts at 50 Hz ... 60 Hz 380 V ... 440 V Main Auxiliary P/ contact contact AC-23A elements elements kW DT PS* Four-hole mounting Weight per PU approx. DT PS* Center-hole mounting Ø 22.5 mm Weight per PU approx. Iu A Order No. kg Order No. kg Main control and EMERGENCY-STOP switches with door-coupling rotary operating mechanism1)2) • With 300 mm switch shaft • Lockable in 0 position with up to 3 padlocks • Degree of protection at front IP65 • Front plate – 3LD2 0, 3LD2 1, 3LD2 2: 67 mm × 67 mm – 3LD2 5 to 3LD2 8: 90 mm × 90 mm. 3 1 NO + 1 NC 7.5 16 } 9.5 25 } } } 11.5 32 22 63 37 100 45 125 } } } A 3LD2 213-0TK53 6 } A A A 3+N 1 NO + 1 NC 7.5 16 9.5 25 11.5 32 } } A } } } } 22 63 } } A 37 100 } } A 45 125 A } A Number and version Rated data of contacts at 50 Hz ... 60 Hz 380 V ... 440 V Main Auxiliary P/ P/ contact contact AC-3 ACelements elements 23A kW kW 3LD2 013–0TK.. +4) 3LD9 220–5C 1 unit 0.412 A 1 unit 0.046 } 3LD2 113–0TK.. +4) 3LD9 220–5C 1 unit 0.407 A 1 unit 0.046 } 3LD2 213–0TK.. +4) 3LD9 220–5C 1 unit 0.405 A 1 unit 0.046 } 3LD2 514–0TK.. +4) 3LD9 250–5C 1 unit 0.655 A 1 unit 3LD2 714–0TK.. +4) 3LD9 280–5C 1 unit 1 unit 0.047 3LD2 814–0TK.. +4) 3LD9 280–5C 1 unit 0.766 1 unit 0.047 3LD2 013–1TL.. +4) 3LD9 220–5C 1 unit 0.412 A 1 unit 0.046 } 3LD2 113–1TL.. +4) 3LD9 220–5C 1 unit 0.450 A 1 unit 0.046 } 3LD2 213–0TK.. +3) 3LD9 220–0C +4) 3LD9 220–5C 1 unit 0.405 A 1 unit 0.039 } 1 unit 0.046 } 3LD2 514–0TK.. +3) 3LD9 250–0C +4) 3LD9 250–5C 1 unit 0.655 A 1 unit 0.080 } 1 unit 3LD2 714–0TK.. +3) 3LD9 280–0C +4) 3LD9 280–5C 1 unit 1 unit 0.102 1 unit 0.047 3LD2 814–0TK.. +3) 3LD9 280–0C +4) 3LD9 280–5C 1 unit 0.766 1 unit 0.102 1 unit 0.047 PS* DT 3LD2 044–0TK.. +4) 3LD9 220–5C 1 unit 0.430 1 unit 0.046 3LD2 144–0TK.. +4) 3LD9 220–5C 1 unit 0.426 1 unit 0.046 3LD2 244–0TK.. +4) 3LD9 220–5C 1 unit 0.427 1 unit 0.046 1 unit 0.710 0.047 A 3LD2 545–0TK.. +4) 3LD9 250–5C 1 unit 0.047 0.765 – 3LD2 044–1TL.. +4) 3LD9 220–5C 1 unit 0.433 1 unit 0.046 3LD2 144–1TL.. +4) 3LD9 220–5C 1 unit 0.461 1 unit 0.046 3LD2 244–0TK.. +3) 3LD9 220–0C +4) 3LD9 220–5C 1 unit 0.427 1 unit 0.039 1 unit 0.046 1 unit 0.710 1 unit 0.080 0.047 A 3LD2 545–0TK.. +3) 3LD9 250–0C +4) 3LD9 250–5C 1 unit 0.047 0.765 – – – Weight per PU approx. Iu A Order No. kg • Four-hole mounting1)4) • Degree of protection at front IP65 6 – 7.5 9.5 25 A 3LD2 113–3VK.. 1 unit 0.604 6 1 NO + 1 NC 9.5 9.5 25 A 3LD2 113–4VP.. 1 unit 0.645 Actuator black red/yellow (EMERGENCY-STOP) > 51 53 > 51 53 For footnotes see Page 6/13. 6/12 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Distribution board mounting Number and version Rated data of contacts at 50 Hz ... 60 Hz 380 V ... 440 V Main Auxiliary P/ contact contact AC-23A elements elements kW PS* DT Weight per PU approx. Iu A Order No. kg ON/OFF and EMERGENCY-STOP switches with masking plate and selector switch • Distribution board mounting • With screw and snap-on mounting on 35 mm mounting rail • Lockable in 0 position with up to 2 padlocks • Degree of protection at front IP44 3 3LD2 530-0TK13 3+N – – 7.5 16 A 3LD2 030–0TK.. 1 unit 0.169 9.5 25 A 3LD2 130–0TK.. 1 unit 0.171 11.5 32 A 3LD2 230–0TK.. 1 unit 0.168 22 63 A 3LD2 530–0TK.. 1 unit 0.311 37 100 A 3LD2 730–0TK.. 1 unit 0.379 45 125 A 3LD2 830–0TK.. 1 unit 0.379 7.5 16 A 3LD2 030–1TL.. 1 unit 0.183 9.5 25 A 3LD2 130–0TK.. +1) 3LD9 220–0C 1 unit 0.171 1 unit 0.039 3LD2 230–0TK.. +1) 3LD9 220–0C 1 unit 0.168 1 unit 0.039 3LD2 530–0TK.. +1) 3LD9 250–0C 1 unit 0.311 1 unit 0.080 3LD2 730–0TK.. +1) 3LD9 280–0C 1 unit 0.379 1 unit 0.102 3LD2 830–0TK.. +1) 3LD9 280–0C 1 unit 0.379 1 unit 0.102 } 11.5 32 22 63 A } A } 37 100 45 125 A } A } Actuator black red/yellow (EMERGENCY-STOP) 6 > 11 13 1) Please order 4th contact elements as neutral conductor separately; see Accessories for base mounting and distribution-board mounting. Footnotes for Page 6/12. 1) Mounting using screws or snap-on mounting on 35 mm standard mounting rail is standard. 2) A terminal cover for the supply side is included in the scope of supply. 3) Please order 4th contact element as neutral conductor separately, see Accessories. 4) With 300 mm switch shaft lockable in 0 position with up to 3 padlocks. Front plate: 67 mm × 67 mm. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/13 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Distribution board mounting Number and version Rated data of contacts at 50 Hz ... 60 Hz 380 V ... 440 V Main Auxiliary P/ contact contact AC-23A elements elements kW PS* DT Weight per PU approx. Iu A Order No. kg ON/OFF and EMERGENCY-STOP switches with masking plate and selector switch • Distribution board mounting • With screw and snap-on mounting on 35 mm mounting rail • Lockable in 0 position with up to 2 padlocks • Degree of protection at front IP44 3 1 NO + 1 NC 7.5 16 A 9.5 25 A } } 11.5 32 A 22 63 37 100 45 125 A 7.5 16 A 9.5 25 } 3LD2 530-0TK13 A A A A 6 A 3+N 1 NO + 1 NC } A } } 11.5 32 A } } 22 63 A A } 37 100 A A } 45 125 A A } 3LD2 030–0TK.. +2) 3LD9 220–5C 1 unit 0.169 1 unit 0.046 3LD2 130–0TK.. +2) 3LD9 220–5C 1 unit 0.171 1 unit 0.046 3LD2 230–0TK.. +2) 3LD9 220–5C 1 unit 0.168 1 unit 0.046 3LD2 530–0TK.. +2) 3LD9 250–5C 1 unit 0.311 1 unit 0.047 3LD2 730–0TK.. +2) 3LD9 280–5C 1 unit 0.379 1 unit 0.047 3LD2 830–0TK.. +2) 3LD9 280–5C 1 unit 0.379 1 unit 0.047 3LD2 030–1TL.. + 3LD9 220–5C 1 unit 0.183 1 unit 0.046 3LD2 130–0TK.. +2) 3LD9 220–5C +1) 3LD9 220–0C 1 unit 0.171 1 unit 0.046 1 unit 0.039 3LD2 230–0TK.. +2) 3LD9 220–5C +1) 3LD9 220–0C 1 unit 0.168 1 unit 0.046 1 unit 0.039 3LD2 530–0TK.. +2) 3LD9 250–5C +1) 3LD9 250–0C 1 unit 0.311 1 unit 0.047 1 unit 0.080 3LD2 730–0TK.. +2) 3LD9 280–5C +1) 3LD9 280–0C 1 unit 0.379 1 unit 0.047 1 unit 0.102 3LD2 830–0TK.. +2) 3LD9 280–5C +1) 3LD9 280–0C 1 unit 0.379 1 unit 0.047 1 unit 0.102 Actuator black red/yellow (EMERGENCY-STOP) > 11 13 1) Please order 4th contact element as neutral conductor separately; see Accessories for base mounting. 2) Please order auxiliary switches 1 NO + 1 NC separately; see Accessories. 6/14 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Molded-plastic enclosure Number and version Rated data of contacts at 50 Hz ... 60 Hz 380 V ... 440 V Main Auxiliary P/ contact contact AC-23A elements elements kW PS* DT Weight per PU approx. Iu A Order No. kg Main control and EMERGENCY-STOP switches • With N or PE/ground terminal • Metric screwed gland • Lockable in 0 position with up to 3 padlocks • Degree of protection at front IP65 3 3+N – – 3LD2 164-0TB53 7.5 16 A 3LD2 064–0TB.. 1 unit 0.463 9.5 25 A 3LD2 164–0TB.. 1 unit 0.463 11.5 32 A 3LD2 264–0TB.. 1 unit 0.465 22 63 A 3LD2 565–0TB.. 1 unit 0.906 37 100 A 3LD2 766–0TB.. 1 unit 1.890 45 125 A 3LD2 866–0TB.. 1 unit 1.890 7.5 16 A 3LD2 064–1TC.. 1 unit 0.453 9.5 25 A 3LD2 164–1TC.. 1 unit 0.487 11.5 32 A 3LD2 264–1TC.. 1 unit 0.500 22 63 A 3LD2 565–1TC.. 1 unit 0.960 37 100 A 3LD2 766–0TB.. +1) 3LD9 280–0C 1 unit 1.890 1 unit 0.102 45 125 A 1 unit 1.890 } 3LD2 866–0TB.. +1) 3LD9 280–0C 1 unit 0.102 16 A 3LD2 064–1GP.. 1 unit 0.507 } 3 3+N 1 NO + 1 NC 1 NO + 1 NC 3LD2 164-1GP53 7.5 9.5 25 A 3LD2 164–1GP.. 1 unit 0.501 11.5 32 A 3LD2 264–1GP.. 1 unit 0.488 22 63 A 3LD2 565–1GP.. 1 unit 0.935 37 100 A 3LD2 766–1GP.. 1 unit 1.830 45 125 A 3LD2 866–1GP.. 1 unit 1.840 7.5 16 A 3LD2 064–1TC.. +1) 3LD9 220–5C 1 unit 0.453 1 unit 0.046 9.5 25 A 3LD2 164–1GP.. +1) 3LD9 220–0C 1 unit 0.501 1 unit 0.039 11.5 32 3LD2 264–1GP.. +1) 3LD9 220–0C 1 unit 0.488 1 unit 0.039 22 63 3LD2 565–1GP.. +1) 3LD9 250–0C 1 unit 0.935 1 unit 0.080 37 100 3LD2 766–1GP.. +1) 3LD9 280–0C 1 unit 1.830 1 unit 0.102 45 125 3LD2 866–1GP.. +1) 3LD9 280–0C 1 unit 1.840 1 unit 0.102 } A } A } A } A } Actuator black red/yellow (EMERGENCY-STOP) 6 > 51 53 1) Please order 4th contact element as neutral conductor separately; see Accessories for base mounting. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/15 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Molded-plastic enclosure Number and version of contacts Rated data at 50 Hz ... 60 Hz 380 V ... 440 V Main contact elements P/ AC-3 P/ AC-23A Iu kW kW A Auxiliary contact elements DT PS* Order No. Weight per PU approx. kg Main control and EMERGENCY-STOP switches with rotary operating mechanism • Metric screwed gland • With N or PE/ground terminal • Degree of protection IP65 6 – 7.5 9.5 25 A 3LD2 165–3VB.. 1 unit 0.880 9.5 11.5 32 A 3LD2 265–3VB.. 1 unit 0.878 18.5 22.0 63 A 3LD2 566–3VB.. 1 unit 2.100 3LD2 165-3VB53 6 Number and version of contacts Rated data at 50 Hz ... 60 Hz 380 V ... 440 V Main contact elements P/ AC-3 P/ AC-23A Iu kW kW A Auxiliary contact elements DT PS* Order No. Weight per PU approx. kg Changeover switch with selector switch operating mechanism, selector switch not lockable • Metric screw connection • With N or PE/ground terminal • Black actuator 3 – 7.5 9.5 25 A 3LD2 165–7UB01 1 unit 0.888 9.5 11.5 32 A 3LD2 265–7UB01 1 unit 0.888 18.5 22.0 63 A 3LD2 566–7UB01 1 unit 2.100 30.0 37.0 100 A 3LD2 766–7UB01 1 unit 2.330 3LD2 165-7UB01 Actuator black red/yellow (EMERGENCY-STOP) 6/16 Siemens LV 30 · 2004 > 51 53 * This quantity or a multiple thereof can be ordered. SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Accessories ■ Selection and ordering data DT 3LD2 0 PS* Weight per PU approx. Order No. DT kg 3LD2 1 and 3LD2 2 PS* Weight per PU approx. Order No. kg For front mounting 4th contact element (neutral conductor) for front mounting leading switch-off delayed switch-on 3LD9 2.0-0B 3LD9 2.0-3B 3LD9 2.0-2B 3LD9 2.0-5B N or PE/ground terminal continuous Auxiliary switch for fitting to left and/or right delayed switch-off, leading switch-on 1 NO + 1 NC 1 NO 1 NC Auxiliary switch for fitting to left and/or right delayed switch-off, with gold-plated contacts for SIMATIC query Labeling plate German/English – } 3LD9 220–0B 1 unit 0.039 } 3LD9 200–2B 1 unit 0.030 } 3LD9 220–2B 1 unit 0.036 } A A 3LD9 220–5B 3LD9 220–3B 3LD9 220–4B 1 unit 1 unit 1 unit 0.046 } 0.029 A 0.029 A 3LD9 220–5B 3LD9 220–3B 3LD9 220–4B 1 unit 1 unit 1 unit 0.046 0.029 0.029 B 3LD9 220–3BF 5 units 0.028 B 3LD9 220–3BF 5 units 0.028 A 3LD9 286–1A 10 units 0.005 A 3LD9 286–1A 10 units 0.005 } 3LD9 220–0C 1 unit 0.039 For base mounting or distribution board mounting – 4th contact element (neutral conductor) for flush mounting on rear leading switch-off delayed switch-on } 3LD9 200–2C 1 unit 0.032 } 3LD9 220–2C 1 unit 0.037 } A A 3LD9 220–5C 3LD9 220–3C 3LD9 220–4C 1 unit 1 unit 1 unit 0.046 } 0.029 A 0.030 A 3LD9 220–5C 3LD9 220–3C 3LD9 220–4C 1 unit 1 unit 1 unit 0.046 0.029 0.030 A 3LD9 286–1A 10 units 0.005 A 3LD9 286–1A 10 units 0.005 For four-hole mounting black red/yellow A A 3LD9 224–1B 3LD9 224–3B 1 unit 1 unit 0.072 A 0.075 A 3LD9 224–1B 3LD9 224–3B 1 unit 1 unit 0.072 0.075 For center-hole mounting black red/yellow A A 3LD9 224–1D 3LD9 224–3D 1 unit 1 unit 0.080 A 0.081 A 3LD9 224–1D 3LD9 224–3D 1 unit 1 unit 0.080 0.081 A 3LD9 286–1A 10 units 0.005 A 3LD9 286–1A 10 units 0.005 Terminal cover as additional touch protection can be snapped on at top and bottom 1-pole (1 pack = 4 units) A 3-pole (1 pack = 4 units) 4-pole (1 pack = 4 units) A 3LD9 201–2A – 3LD9 201–1A 1 unit 0.007 A A 0.007 3LD9 221–2A 3LD9 221–0A – 1 unit 1 unit 0.004 0.007 N or PE/ground terminal continuous 3LD9 2.0-0C Auxiliary switch for fitting to left and/or right delayed switch-off, leading switch-on 1 NO + 1 NC 1 NO 1 NC 3LD9 2.0-2C 6 Labeling plate German/English For front and base mounting Rotary operating mechanism lockable in 0 position with up to 3 padlocks 3LD9 286-1A 3LD9 2.4-1A Labeling plate German/English 3LD9 2.1-0A 3LD9 2.1-2A * This quantity or a multiple thereof can be ordered. 1 unit Siemens LV 30 · 2004 6/17 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Accessories DT 3LD2 5 PS* Weight per PU approx. DT 3LD2 7 and 3LD2 8 Order No. PS* Weight per PU approx. Order No. For front mounting 3LD9 2.0-0B 3LD9 2.0-3B 3LD9 2.0-2B 3LD9 2.0-5B 4th contact element (neutral conductor) for front mounting leading switch-off delayed switch-on } 3LD9 250–0B 1 unit 0.079 } 3LD9 280–0B 1 unit 0.101 N or PE/ground terminal continuous } 3LD9 250–2B 1 unit 0.072 } 3LD9 280–2B 1 unit 0.092 A A A 3LD9 250–5B 3LD9 250–3B 3LD9 250–4B 1 unit 1 unit 1 unit 0.047 A 0.029 A 0.028 A 3LD9 280–5B 3LD9 280–3B 3LD9 280–4B 1 unit 1 unit 1 unit 0.047 0.030 0.029 A 3LD9 286–1A 10 units 0.005 A 3LD9 286–1A 10 units 0.005 4th contact element (neutral conductor) for flush mounting on rear leading switch-off delayed switch-on } 3LD9 250–0C 1 unit 0.080 } 3LD9 280–0C 1 unit 0.102 N or PE/ground terminal continuous } 3LD9 250–2C 1 unit 0.073 } 3LD9 280–2C 1 unit 0.093 A A A 3LD9 250–5C 3LD9 250–3C 3LD9 250–4C 1 unit 1 unit 1 unit 0.047 A 0.030 A 0.029 A 3LD9 280–5C 3LD9 280–3C 3LD9 280–4C 1 unit 1 unit 1 unit 0.047 0.029 0.029 A 3LD9 286–1A 10 units 0.005 A 3LD9 286–1A 10 units 0.005 For four-hole mounting black red/yellow A A 3LD9 284–1B 3LD9 284–3B 1 unit 1 unit 0.154 A 0.152 A 3LD9 284–1B 3LD9 284–3B 1 unit 1 unit 0.154 0.152 For center-hole mounting black red/yellow A A 3LD9 284–1D 3LD9 284–3D 1 unit 1 unit 0.155 0.155 – – A 3LD9 286–1A 10 units 0.005 A 3LD9 286–1A 10 units 0.005 Terminal cover as additional touch protection can be snapped on at top and bottom 1-pole (1 pack = 4 units) A 3-pole (1 pack = 4 units) A 4-pole (1 pack = 4 units) 3LD9 251–2A 3LD9 251–0A – 4 units 1 unit 0.125 A 0.009 3LD9 281–2A – – 1 unit 0.006 Auxiliary switch for fitting to left and/or right delayed switch-off, leading switch-on 1 NO + 1 NC 1 NO 1 NC Labeling plate German/English For base mounting or distribution board mounting 3LD9 2.0-0C Auxiliary switch for fitting to left and/or right delayed switch-off, leading switch-on 1 NO + 1 NC 1 NO 1 NC 6 3LD9 2.0-2C Labeling plate German/English For front and base mounting Rotary operating mechanism lockable in 0 position with up to 3 padlocks 3LD9 286-1A 3LD9 2.4-1A Labeling plate German/English 3LD9 2.1-0A 6/18 3LD9 2.1-2A Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Project planning aids ■ Dimension drawings Front mounting Switch for center-hole mounting with rotary operating mechanism 3LD2 .54, 3LD2 555 N L Drilling diagram C M K 24,1 NSG00206 F B G 3,2 A 22,5 max. 5,5 mm With 3LD2 0, 4-pole base Switch for four-hole mounting with rotary operating mechanism 3LD2 .03, 3LD2 .04 N L Drilling diagram C K A1 D NSG00207 F B G M A1 A d max. 5,5 mm Sealing plate behind masking frame Make sure shaft seal is in proper position 6 With 3LD2 0, 4-pole base Switch for center-hole mounting with selector switch 3LD2 .50 N Drilling diagram C K M L A 24,1 NSG00208 F B G 3,2 22,5 With 3LD2 0, 4-pole base max. 5,5 mm Switch for four-hole mounting with selector switch 3LD2 .22 N Drilling diagram C K A1 D A NSG00209 F B G M A1 d L max. 5,5 mm Sealing plate behind masking frame Make sure shaft seal is in proper position With 3LD2 0, 4-pole base Type A B A1 C D d F G K L M1) N1) 3LD2 054 3LD2 154/3LD2 254 3LD2 .55 3LD2 003 3LD2 103/3LD2 203 3LD2 504 3LD2 704 3LD2 804 3LD2 050 3LD2 150/3LD2 250 3LD2 022 3LD2 122/3LD2 222 67 67 90 67 67 90 90 90 49 49 49 49 67 67 90 67 67 90 90 90 49 49 49 49 – – – 48 48 48 48 48 – – 36 36 48 46 60 48 46 60 71 71 48 46 48 46 – – – 10 10 10 10 10 – – 10 10 – – – 5.0 5.0 5.0 5.0 5.0 – – 5.0 5.0 50 55 64 50 55 64 83 83 50 55 50 55 38 44 50 38 44 50 54 54 38 44 38 44 37 37 46 37 37 46 46 46 32 32 32 32 74 74 81 50 50 59 61 61 74 74 50 50 16 16 16 16 16 16 16 16 22 22 22 22 46 46 46 46 46 46 46 46 45 45 45 45 1) Additional labeling plate, see Accessories. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/19 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Project planning aids Switch for four-hole mounting with rotary operating mechanism 3LD2 103–.V…, 3LD2 504–.V… N C K Drilling diagram M L A1 A1 F B D NSG00215 d A max. 5,5 mm Sealing plate behind masking frame Make sure shaft seal is in proper position Switch for four-hole mounting with selector switch 3LD2 122–.V… N C K Drilling diagram A1 D F B G M A1 NSG00216 d A L Sealing plate behind masking frame Make sure shaft seal is in proper position max. 5,5 mm Changeover switches 3LD2 123–7U…, 3LD2 223–7U…, 3LD2 524–7U…, 3LD2 724–7U… C K N M Drilling diagram G A1 A1 D F B d NSG00217 6 A L Sealing plate behind masking frame Make sure shaft seal is in proper position max. 5,5 mm Type A B A1 C D d F G K L M1) N1) 3LD2 103–.V... 3LD2 103–.V... 3LD2 203–.V... 3LD2 504–.V... 3LD2 122–.V... 3LD2 123–.7U... 3LD2 223–.7U... 3LD2 524–.7U... 3LD2 724–.7U... 67 67 67 90 49 67 67 92 92 67 67 67 90 49 67 67 92 92 48 48 48 48 36 48 48 68 68 91 91 91 121 91 91 91 121 141 10 10 10 10 10 10 10 10 10 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.5 5.5 55 55 55 64 55 28 28 32 32 44 44 44 50 44 46 46 53 68 37 37 37 46 32 34 34 40 40 50 50 50 59 50 63.5 63.5 73 75 16 16 16 16 – – – – – 46 46 46 46 – – – – – 1) Additional front label, see Accessories. 6/20 Siemens LV 30 · 2004 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Project planning aids Base mounting Switch for base mounting with detachable rotary operating mechanism (four-hole mounting) 3LD2 .13, 3LD2 14. X = L + 52 mm L1 N 79 K Drilling diagram Door C Floor B1 A1 NSG00210 A B2 D F B G M A1 d e 5 L Switch for base mounting with detachable rotary operating mechanism (center-hole mounting) 3LD2 .44, 3LD2 .45 X = L + 74 mm L1 101 B1 24,1 G 3,2 NSG00211 F B A Floor Drilling diagram Door C K M 5 B2 N 22,5 e L Type A B A1 1B B2 C D d e F G K L L1 M1) N1) 3LD2 013 3LD2 113/3LD2 213 3LD2 514 3LD2 714 3LD2 814 3LD2 044 3LD2 144/3LD2 244 3LD2 545 67 67 90 90 90 67 67 90 67 67 90 90 90 67 67 90 48 48 48 48 48 – – – 22 22 25 25 25 22 22 25 60 60 70 90 90 60 60 70 48 46 60 71 71 48 46 60 10 10 10 10 10 – – – 5.0 5.0 5.5 5.5 5.5 – – – 4.5 4.5 5.5 5.5 5.5 4.5 4.5 5.5 50 55 64 83 83 50 55 64 38 44 50 54 54 38 44 50 37 37 46 46 46 37 37 46 330 330 338 340 340 330 330 338 58 58 68 70 70 58 58 68 16 16 16 16 16 16 16 16 46 46 46 46 46 46 46 46 1) Additional front label, see Accessories. Switch for base mounting with detachable rotary operating mechanism (four-hole mounting) 3LD2 113–.V… X = L + 52 mm N L1 79 C Drilling diagram Door M K Floor B1 Type 3LD2 113-.V... A1 d NSG00218 A A 67 B2 D G B G A1 e 5 B 67 L A1 48 1B 22 B2 60 C 46 D 10 d 5.0 e 4.5 F 55 G 44 K 37 L 330 L1 58 M1) 16 N1) 46 1) Additional front label, see Accessories. Distribution board mounting Switch for distribution board mounting with selector switch 3LD2 .30 NSG00212 45 L K C K1 F B A Type A B C F K 1K L 3LD2 030 3LD2 130 3LD2 230 3LD2 530 3LD2 730 3LD2 830 53 53 53 64 71 71 45 45 45 45 45 45 47 46 46 60 71 71 50 55 55 64 83 83 41 41 41 43 46 46 14 14 14 16 19 19 37 37 37 43 44 44 5 Siemens LV 30 · 2004 6/21 6 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Project planning aids Molded-plastic enclosure Switch with molded-plastic enclosure with rotary operating mechanism Metric screwed glands Heavy-gauge threaded joints 3LD2 .61, 3LD2 .62, 3LD2 .63 M A K A1 H d A1 M NSG00214 B1 B1 NSG00213 B K B1 B K H Drilling diagram A1 B1 A K B1 3LD2 .64, 3LD2 .65, 3LD2 .66 d G G Type A B A1 1B C d D E F G H K M 3LD2 .61 3LD2 .62 3LD2 .63 3LD2 .64 3LD2 .65 3LD2 .66 94 134 212 100 146 212 125 160 302 140 176 302 80 120 189 – – 189 110 146 238 152 188 238 36 60 84 46 66 84 4.5 4.5 6.5 4.5 4.5 6.5 4 × PG 16 4 × PG 21/29 4 × PG 36/42 4 × M 25 4 × M 32/40 4 × M 50/63 21 56 82 24 37 82 – – 2 × PG 13.5 – – 2 × M 20 – 2 × PG 13.5 4 × PG 13.5 4 × M 20 4 × M 20 4 × M 20 82 104 136 81 104 136 67 90 90 67 90 90 36 45 45 36 45 45 Switch in molded-plastic enclosure with rotary operating mechanism 3LD2 165–.V…, 3LD2 265–.V…, 3LD2 566–.V… B1 N NSG00219 B K Drilling diagram 3LD2 .66 Drilling diagram 3LD2 .65 A1 A1 B1 M B1 H B1 6 A K d d G Type A B A1 1B C d D E F G H K M N 3LD2 165–.V... 3LD2 265–.V... 3LD2 566–.V... 146 146 212 176 176 302 – – 189 188 188 238 66 66 84 4.5 4.5 6.5 4 × M 32/40 4 × M 32/40 4 × M 32/40 37 37 82 – – 2 × M 20 4 × M 20 4 × M 20 4 × M 20 104 104 136 67 67 90 45 45 45 2 × M 20, 2 × M 40 2 × M 20, 2 × M 40 2 × M 20, 2 × M 50 Switch in molded-plastic enclosure with selector switch 3LD2 103–.V…, 3LD2 504–.V… B1 N NSG00220 B K Drilling diagram 3LD2 .66 Drilling diagram 3LD2 .65 A1 A1 B1 M B1 H B1 A K d d G Type A B A1 1B C d D E F G H K M N 3LD2 165–.7U... 3LD2 265–.7U... 3LD2 566–.7U... 3LD2 766–.7U... 146 146 212 212 176 176 302 302 – – 189 189 188 188 238 238 66 66 84 84 4.5 4.5 6.5 6.5 4 × M 32/40 4 × M 32/40 4 × M 32/40 4 × M 50/63 37 37 82 82 – – 2 × M 20 2 × M 20 4 × M 20 4 × M 20 4 × M 20 4 × M 20 104 104 136 136 67 67 90 90 45 45 45 45 2 × M 20, 2 × M 40 2 × M 20, 2 × M 40 2 × M 20, 2 × M 50 2 × M 20, 2 × M 50 6/22 Siemens LV 30 · 2004 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Project planning aids Maintenance switches 3LD2 .64, 3LD2 .65, 3LD2 .66 A 8HP27 NSG00222 A1 G I F D J B1 B1 NSG00221 d C B A1 E L H K Type A B A1 1B d Type C D E F G H I J K L 3LD2 .64 3LD2 .65 3LD2 .66 100 146 212 140 176 302 – – 189 152 188 238 4.5 4.5 6.5 8HP27 07, 8HP27 47 8HP27 07, 8HP27 47 8HP27 11, 8HP27 48 8HP27 12, 8HP27 61 8HP27 17, 8HP27 62 8HP27 18, 8HP27 63 8HP27 38, 8HP27 58 80 80 245 230 230 220 250 114 114 245 230 230 220 95 307 307 307 307 307 307 307 307 307 614 614 614 614 614 – – 236 236 236 236 236 273 273 580 580 580 580 580 273 273 273 273 273 273 273 236 236 236 236 236 236 236 235 235 235 350 350 350 350 167 167 167 260 260 260 260 Front mounting 3LD9 2.0–0B fourth contact element (neutral conductor) for front mounting, leading switch-off, delayed switch-on 3LD9 2.0–2B N or PE/ground terminals for front mounting, continuous, leading switch-off, delayed switch-on F F N N C N C H H N 6 E E B A G B A G NSE00929 NSE00928 Type A B C E F G H Type A B C E F G H 3LD9 220–0B 3LD9 250–0B 3LD9 280–0B 54.5 64.0 83.5 47.0 47.0 44.0 15.5 20.0 20.0 42.0 43.5 42.0 10.0 3.0 0.0 31.5 37.0 73.0 27.5 33.5 43.2 3LD9 200–2B 3LD9 220–2B 3LD9 250–2B 3LD9 280–2B 46.0 54.5 64.5 83.5 34.5 47.0 47.0 46.5 10.6 15.5 20.0 23.0 42.0 42.0 43.5 42.0 0.0 10.0 3.0 0.0 46.0 31.5 37.0 73.0 27.5 27.5 33.5 43.2 3LD9 2.0–3B auxiliary switches for fitting to left and/or right, delayed switch-off, leading switch-on, 1 NO 3LD9 2.0–5B auxiliary switches for fitting to left and/or right, delayed switch-off, leading switch-on, 1 NO + 1 NC G B B G A A C 13 14 13 14 C NSE00931 NSE00930 11 12 H H Type A B C G H Type A B C G H 3LD9 220–5B 3LD9 250–5B 3LD9 280–5B 50.5 50.5 50.5 34.5 34.5 34.5 18.5 18.5 18.5 46.0 46.0 46.0 27.5 33.5 43.2 3LD9 220–3B 3LD9 250–3B 3LD9 280–3B 3LD9 220–3BF 50.5 50.5 50.5 50.5 34.5 34.5 34.5 34.5 10.6 10.6 10.6 10.6 46.0 46.0 46.0 46.0 27.5 33.5 43.2 27.5 Siemens LV 30 · 2004 6/23 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Project planning aids Front mounting 3LD9 2.0–4B auxiliary switches for fitting to left and/or right, delayed switch-off, leading switch-on, 1 NC 3LD9 286–1A labeling plate German/English G B 5 47 11 MAIN SWITCH HAUPTSCHALTER NSE00933 A 11 12 C NSE00932 H Type A B C G H 3LD9 220–4B 3LD9 250–4B 3LD9 280–4B 50.5 50.5 50.5 34.5 34.5 34.5 10.6 10.6 10.6 46.0 46.0 46.0 27.5 33.5 43.2 Front and base mounting 3LD9 2.4–1B, 3LD9 2.4–3B rotary operating mechanisms for four-hole mounting black, red/yellow A C A C B B 6 3LD9 2.4–1D, 3LD9 2.4–3D rotary operating mechanisms for center-hole mounting black, red/yellow NSE0035 NSE0034 Type A B C Type A B C 3LD9 224–1B 3LD9 224–3B 3LD9 284–1B 3LD9 284–3B 67.0 67.0 90.0 90.0 67.0 67.0 90.0 90.0 37.0 37.0 46.0 46.0 3LD9 224–1D 3LD9 224–3D 3LD9 284–1D 3LD9 284–3D 67.0 67.0 90.0 90.0 67.0 67.0 90.0 90.0 37.0 37.0 46.0 46.0 3LD9 2.1–2A terminal cover as additional touch protection for snapping on at top or bottom, 1-pole 3LD9 2.1–2A terminal covers as additional touch protection for snapping on at top or bottom, 1-pole B A A A-A NSE00937 A NSE00936 A B A Warning label attached A-A B A C Type A B C Type A B C 3LD9 201–2A 3LD9 221–2A 3LD9 251–2A 3LD9 281–2A 34.5 34.5 40.5 45.0 15.0 20.0 21.5 17.5 10.0 15.0 20.0 23.0 3LD9 221–0A 3LD9 251–0A 3LD9 201–1A 34.5 40.5 34.5 20.0 21.5 15.0 46.0 60.0 46.0 6/24 Siemens LV 30 · 2004 SENTRIC Switch Disconnectors SENTRIC LD Main Control and EMERGENCY-STOP Switches from 16 A to 125 A Project planning aids Base and distribution board mounting 3LG9 2.0–0C fourth contact elements (neutral conductor) for flush mounting on rear, leading switch-off, delayed switch-on 3LD9 2.0–2C N or PE/ground terminals continuous A A G F F E B E B G H C N N C N N H NSE00939 NSE00938 Type A B C E F G H Type A B C E F G H 3LD9 220–0C 3LD9 250–0C 3LD9 280–0C 54.5 64.5 83.5 47.0 47.0 44.0 15.5 20.0 23.0 42.0 43.0 44.0 5.0 4.0 3.0 31.5 37.0 73.0 27.5 33.5 43.2 3LD9 200–2C 3LD9 220–2C 3LD9 250–2C 3LD9 280–2C 46.0 54.5 64.5 83.5 43.0 47.0 47.0 44.0 10.6 15.5 20.0 23.0 43.0 42.0 43.0 44.0 5.0 5.0 4.0 3.0 46.0 31.5 37.0 73.0 27.5 27.5 33.5 43.2 3LD9 2.0–5C auxiliary switches for fitting to left and/or right, delayed switch-off, leading switch-on 1 NO + 1 NC 3LD9 2.0–3C auxiliary switches for fitting to left and/or right, delayed switch-off, leading switch-on, 1 NO G 6 B B G A A NSE00940 C 13 14 11 12 C NSE00941 13 14 H H Type A B C G H Type A B C G H 3LD9 220–5C 3LD9 250–5C 3LD9 280–5C 50.5 50.5 50.5 34.5 34.5 34.5 18.5 18.5 18.5 46.0 46.0 46.0 27.5 33.5 43.2 3LD9 220–3C 3LD9 250–3C 3LD9 280–3C 50.5 50.5 50.5 34.5 34.5 34.5 10.6 10.6 10.6 46.0 46.0 46.0 27.5 33.5 43.2 3LD9 2.0–4C auxiliary switches for fitting to left and/or right, delayed switch-off, leading switch-on, 1 NC B G A 11 12 C NSE00942 H Type A B C G H 3LD9 220–4C 3LD9 250–4C 3LD9 280–4C 50.5 50.5 50.5 34.5 34.5 34.5 10.6 10.6 10.6 46.0 46.0 46.0 27.5 33.5 43.2 Siemens LV 30 · 2004 6/25 SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A General data ■ Area of application ■ Design SENTRIC KA and 3KE switch disconnectors are used as main control, EMERGENCY-STOP, maintenance and transfer switches in distribution boards for residential and non-residential buildings as well as industrial switchboards. As three and four-pole variants, they ensure activation and deactivation of the specified rated current under load. At the same time, they constitute a safety isolating function and isolating distance in all low-voltage circuits. By virtue of their design, all 3K switch disconnectors feature double contact interruption and an isolating distance. Therefore, the fuses are de-energized when the switch disconnectors are in the disconnected position. All 3K switch disconnectors are climate-proof and meet the requirements of IEC 60947-1, IEC 60947-3 and VDE 0660 Part 107. A changeover operating mechanism is available for the use of 2 switch disconnectors in the 3KE series as load changeover switches. Switch disconnectors in the type-tested 8HP molded-plastic distribution board enclosure (degree of protection IP65) are available for use as safety switches. An operating linkage permits simultaneous switching of two 3KE switch disconnectors with identical or different rated operating currents. The system components can be selected in the "8HP System" catalog (Order No. 8ZX1012-0HP54-5AB1) (in German only). Identical accessories for 3KA, 3KL and 3KM switch disconnectors with and without fuses simplify keeping of stocks. For the SENTRIC KA switch disconnectors, complete kits for standard and EMERGENCY-STOP use are available for installation in the side and rear panels of switchgear cabinets. ■ Technical specifications Permissible mounting position 10° 6 180° 180° NSE00182 3KE 6/26 3KA Siemens LV 30 · 2004 180° SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A General data ■ Technical specifications IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Standards 3KA51 3KA52 3KA53 1) 3KA55 3KA571) 3KA58 A 63 80 125 160 250 400 6303) A 63 80 125 160 250 400 630 3) V 690 690 1000 1000 1000 1000 1000 6 8 8 8 8 8 Type 3KA50 Rated uninterrupted current Iu Conventional free-air thermal current Ith 2) Rated insulation voltage Ui Rated impulse withstand voltage Uimp kV 6 Rated operating voltage Ue AC 50 Hz/60 Hz DC Rated short-circuit making capacity with back-up fuses 4) at AC 50 Hz/60 Hz 690 V Rated conditional short-circuit current with back-up fuses 4) at AC 50 Hz/60 Hz 690 V max. rated current In of the fuses V 690 V 440 (3 conducting paths series-connected), 220 (2 conducting paths series-connected) kA (peak value) 220 220 220 220 220 220 220 kA (rms value) 100 A 63 100 80 100 160 100 160 80 400 80 400 50 630 Permissible let-through current of the fuses kA 8 10 17 17 30 5) 30 5) 40 5) Maximum permissible let-through I2t value kA2s 55 55 223 223 1000 1000 2600 Permissible let-through current of a seriesconnected circuit-breaker at AC 50 Hz/60 Hz 690 V kA (peak value) 7 8 8 15 25 25 32 Rated short-circuit making capacity without fuses at AC 50 Hz/60 Hz 690 V kA (peak value) 7 7 7 9 20 25 35 650 1000 1280 2000 3200 5040 80 40 125 65 160 80 250 132 400 200 6306) 350 640 Switching capacity (feed-in from the top or bottom) at AC 400 V Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A at AC 500 V Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21A, AC-22A AC-23A Motor switching capacity AC-23A at AC 690 V Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21A, AC-22A AC-23A Motor switching capacity AC-23A A (rms value) 500 A 63 kW 30 A (rms value) 500 1000 1280 2000 3200 3200 80 80 50 125 90 160 160 110 250 250 185 400 400 280 630 4006) 280 500 1000 1280 2000 3200 3200 80 63 50 125 125 110 160 160 150 250 250 220 400 400 375 630 4006) 375 A 250 A 63 260 63 500 125 640 160 10007) 2508) 1600 400 1600 400 kA (rms value) 2.5 2.5 3.2 3.2 8 11 15 80 80 80 80 80 80 125 125 125 125 125 125 160 160 160 160 160 160 250 250 250 250 250 250 400 400 400 400 400 400 630 620 600 580 560 550 A A kW A (rms value) 500 A 63 A 63 kW 50 at DC 440 V (3 conducting paths series-connected) Breaking current Ic (L/R = 15 ms) Rated operating current Ie with DC-23A Rated short-time current (1 s current) 63 63 40 Permissible load depending on the ambient temperature of the switch for open-type installation in switchboards (e.g. 8NA1), in switchgear panels or switchgear racks at 35 °C 40 °C 45 °C 50 °C 55 °C 60 °C Permissible ambient temperature A A A A A A 63 63 63 63 63 63 °C –25 ... +55 in operation, –50 ... +80 when stored3) 1) Technical specifications for CSA approval on request. 2) Configuring note: max. permissible operating temperature at connections 100 °C. 3) With 3KA58 for operation –25 °C to +35 °C, 570 A at 55 °C. 4) Only with 3NA38, 3NA32 or 3ND18, 3ND12 fuses (otherwise only 105 kA/50 kA). 5) 3ND1 switchgear protection fuse. 6) AC-23B. 7) At 440 V L/R = 4 ms, at 220 V L/R = 15 ms. 8) At 440 V DC-22 A, at 220 V DC-23 A. Siemens LV 30 · 2004 6/27 6 SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A General data IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Standards Type 3KA50 Mechanical endurance Required operating torque Degree of protection Power loss of the switch at Ith Main conductor connection Busbar systems, max. dimensions (w × t) Cable lug, max. conductor cross-section (stranded) Tightening torque Terminal screws PE/ground-conductor connection Flat bars Cable lug, max. conductor cross-section (stranded) Fourth pole Rated uninterrupted current Iu Rated operating current Ie at AC-21A, AC 690 V Main conductor connection Flat bars Cable lug max. conductor cross-section (stranded) Auxiliary switch 1 NO + 1 NC (accessory) Max. number to be plugged 6 Oper. cycles 15000 Nm 3 W 7 Siemens LV 30 · 2004 3KA571) 3KA58 12000 12000 12000 3 7.5 7.5 16 16 16 22 33 72 170 25 × 9 35 45 × 10 70 45 × 10 120 40 × 12 150 40 × 12 2 × 150 or 1 × 240 40 × 15 2 × 240 6–7.5 M6 7–10 M6 18–22 M8 35–45 M 10 35–45 M 10 35–45 M 10 mm × mm – mm2 – – – – – – – 20 × 2.5 70 20 × 2.5 120 20 × 2.5 120 A – A – – – – – 125 125 400 400 400 400 400 400 mm × mm – mm2 – – – – – 15 × 3 70 25 × 4 240 25 × 4 240 25 × 4 240 1 1 2 2 2 2 2 2.560 2.200 2.560 2.200 5.400 5.360 6.401 5.963 mm × mm 25 × 9 mm2 35 Nm 6–7.5 M6 A 10 A 4 A 1.2 A 0.4 A 0.2 6/28 3KA55 15000 22 Rated operating current Ie at DC Ie/DC-13 at Ue = 24 V Ie/DC-13 at Ue = 48 V Ie/DC-13 at Ue = 110 V Ie/DC-13 at Ue = 220 V Ie/DC-13 at Ue = 440 V 1) Technical specifications for CSA approval on request. 3KA531) 15000 12 A 10 A 6 A 4 A 2.5 A 21.2 Weight Complete version Basic version 3KA52 15000 IP00/IP20 (from the operating side, with busbar and terminal covers) Rated operating current Ie at AC 50 Hz/60 Hz Ie/AC-12 Ie/AC-15 at Ue = 220 V/230 V Ie/AC-15 at Ue = 380 V/400 V Ie/AC-15 at Ue = 500 V Ie/AC-15 at Ue = 690 V Connection Solid Flexible with end sleeve 3KA51 mm2 2 × (1–2.5) mm2 2 × (0.5–1.5) kg 1.324 kg 1.040 1.322 1.039 SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A General data IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Standards Type Rated uninterrupted current Iu 3KE42 A 250 Rated insulation voltage Ui Rated impulse withstand voltage Uimp Rated operating voltage Ue AC 50 Hz/60 Hz DC 3KE43 3KE44 3KE45 400 630 1000 8 8 AC 1000 V, DC 1200 V kV 8 8 V 690 V 440 (3 conducting paths series-connected), V 220 (2 conducting paths series-connected) Rated short-circuit making capacity at AC 50 Hz/60 Hz 690 V kA (peak value) 35 35 60 60 Rated short-circuit making capacity with back-up fuses at AC 50 Hz/60 Hz 690 V kA (peak value) 105 105 105 84 kA (rms value) 50 50 50 40 2150 5400 19000 Rated conditional short-circuit current with back-up fuses at AC 50 Hz/60 Hz 690 V Maximum permissible let-through I2t value kA2s 2150 Permissible let-through current of a series-connected circuit-breaker at AC 50 Hz/60 Hz 690 V kA (peak value) 35 35 60 60 max. rated current In of the fuses Permissible let-through current of the fuses A 400 kA (peak value) 38 400 38 630 60 1000 75 1000 2520 2520 440 330 125 630 630 315 1000 800 315 1000 2520 2520 400 330 125 630 630 315 1000 800 315 1000 2520 2520 A 250 A 250 A 125 400 330 315 630 630 315 1000 800 315 A 1000 1000 2520 2520 A 250 A 250 400 250 630 630 1000 630 kA (rms value) 12.5 12.5 21 21 400 400 400 400 380 630 630 630 630 600 1000 960 930 890 810 Switching capacity (feed-in from the top or bottom) at AC 400 V Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21A AC-22A AC-23A at AC 500 V Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21A AC-22A AC-23A at AC 690 V Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21A AC-22A AC-23A at DC 440 V (3 conducting paths series-connected) Breaking current Ic (L/R = 5 ms) Rated operating current Ie at DC-21A DC-22A Rated short-time current (1 s current) Permissible load depending on the ambient temperature of the switch for open-type installation in switchboards (e.g. 8NA1), in switchgear panels or switchgear racks at 35 °C 40 °C 45 °C 50 °C 60 °C For enclosed installation, e.g. in 8HP systems A (rms value) 1000 A 250 A 250 A 125 A (rms value) 1000 A 250 A 250 A 125 A (rms value) 1000 A A A A A 250 250 250 250 240 6 see "8HP System" Catalog. Order No. E20001-8ZX1012-0HP54-5AB1 (in German only) Siemens LV 30 · 2004 6/29 SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A General data IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Standards Type 3KE42 Permissible ambient temperature Mechanical endurance Degree of protection 3KE43 3KE44 3KE45 °C 25 ... +55 in operation, –50 ... +80 when stored Oper. cycles 10000 IP00 Required operating torque Nm 15 15 24 24 Required operating torque for changeover operating mechanism with interruption without interruption Nm 20 Nm 35 20 35 30 55 30 55 W 15 33 78 180 25 × 10 2 × 150, 1 × 240 2 × 40 × 10 2 × 240 2 × 40 × 10 2 × 240 Power loss of the switch disconnector at Ith Main conductor connection Busbar systems, max. dimensions (w × t) Cable lug, max. conductor cross-section (stranded) mm × mm 25 × 10 mm2 2 × 150 Auxiliary switch 1 NO + 1 NC (accessory) Rated insulation voltage Ui V 500 Rated operating current Ie (same potential at contacts) at AC 50 Hz/60 Hz Ie/AC-1 at Ue = 500 V Ie/AC-11 at Ue = 230 V A 10 A 6 Rated operating current Ie (same potential at contacts) at DC Ie/DC-11 at Ue = 24 V Ie/DC-11 at Ue = 220 V A 10 A 0.4 Connection Solid Flexible with end sleeve Short-circuit protection (tested as per DIN VDE 0660 with 1000 A) 6 6/30 Siemens LV 30 · 2004 mm2 2 × 2.5 mm2 2 × 1.5 6 A TDz, 10 A Dz or 10 A G-type m.c.b. SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A Base mounting ■ Area of application SENTRIC KA switch disconnectors are used as main control and EMERGENCY-STOP switches for operational switching duty and for isolating main and auxiliary circuits. Another field of application is the switching of induction motors and other loads in the event of maintenance and repair. Main control and EMERGENCY-STOP switches are manually operated switch disconnectors according to IEC 60947-3 and VDE 0660 Part 107 (EN 60947-3) and fulfill the conditions for switch disconnectors and the requirements of the machinery directive EN 60204-1. ■ Selection and ordering data All switch disconnectors in IP00 degree of protection Conductor connecting screws are generally included in the scope of delivery. Rated DT uninterrupted current Iu Complete PS* version with 8UC6 door-coupling rotary operating mechanism (black handle) Weight DT Basic switch per PU version approx. without handle A Order No. kg PS* Order No. Weight DT per PU approx. 8UC6 EMERPS* GENCY-STOP door-coupling rotary operating mechanism (red handle, yellow indicator plate) Weight per PU approx. kg Order No. kg 3-pole for motor loads 3KA53 30–1AE01 63 80 125 160 B B B B 3KA50 30–1EE01 3KA51 30–1EE01 3KA52 30–1EE01 3KA53 30–1EE01 1 unit 1 unit 1 unit 1 unit } } } } 3KA50 30–1AE01 3KA51 30–1AE01 3KA52 30–1AE01 3KA53 30–1AE01 1 unit 1 unit 1 unit 1 unit } } } } 8UC61 21–3BB10 8UC61 21–3BB10 8UC62 22–3BB20 8UC62 22–3BB20 1 unit 1 unit 1 unit 1 unit 250 400 630 B B B 3KA55 30–1EE01 3KA57 30–1EE01 3KA58 30–1EE01 1 unit 5.470 } 1 unit 5.550 } 1 unit 6.120 } 3KA55 30–1AE01 3KA57 30–1AE01 3KA58 30–1AE01 1 unit 4.510 } 1 unit 4.630 } 1 unit 5.150 } 8UC63 23–3BB30 8UC63 23–3BB30 8UC63 23–3BB30 1 unit 0.999 1 unit 0.999 1 unit 0.999 1.440 1.400 2.380 2.420 0.946 0.918 1.880 2.020 0.353 0.353 0.426 0.426 3-pole for power distribution 3KA53 30–1AE01 63 80 125 160 B B B B 3KA50 30–1EE01 3KA51 30–1EE01 3KA52 30–1EE01 3KA53 30–1EE01 1 unit 1 unit 1 unit 1 unit } } } } 3KA50 30–1AE01 3KA51 30–1AE01 3KA52 30–1AE01 3KA53 30–1AE01 1 unit 1 unit 1 unit 1 unit } } } } 8UC61 21–3BB10 8UC61 21–3BB10 8UC62 22–3BB20 8UC62 22–3BB20 1 unit 1 unit 1 unit 1 unit 250 400 630 B B B 3KA55 30–1EE01 3KA57 30–1EE01 3KA58 30–1EE01 1 unit 5.470 } 1 unit 5.550 } 1 unit 6.120 } 3KA55 30–1AE01 3KA57 30–1AE01 3KA58 30–1AE01 1 unit 4.510 } 1 unit 4.630 } 1 unit 5.150 } 8UC63 23–3BB30 8UC63 23–3BB30 8UC63 23–3BB30 1 unit 0.999 1 unit 0.999 1 unit 0.999 1.440 1.400 2.380 2.420 0.946 0.918 1.880 2.020 0.353 0.353 0.426 0.426 4-pole1) for power distribution 3KA53 40–1AE01 63 80 125 160 B B B B 3KA50 40–1EE01 3KA51 40–1EE01 3KA52 40–1EE01 3KA53 40–1EE01 1 unit 1 unit 1 unit 1 unit B B B B 3KA50 40–1AE01 3KA51 40–1AE01 3KA52 40–1AE01 3KA53 40–1AE01 1 unit 1 unit 1 unit 1 unit } } } } 8UC62 22–3BB20 8UC62 22–3BB20 8UC62 22–3BB20 8UC62 22–3BB20 1 unit 1 unit 1 unit 1 unit 250 400 630 B B C 3KA55 40–1EE01 3KA57 40–1EE01 3KA58 40–1EE01 1 unit 6.030 C 1 unit 5.150 B 1 unit 6.590 B 3KA55 40–1AE01 3KA57 40–1AE01 3KA58 40–1AE01 1 unit 5.040 } 1 unit 5.190 } 1 unit 5.740 } 8UC63 23–3BB30 8UC63 23–3BB30 8UC63 23–3BB30 1 unit 0.999 1 unit 0.999 1 unit 0.999 2.490 2.540 2.490 2.450 2.100 2.110 2.090 2.240 0.426 0.426 0.426 0.426 1) Rated values reduced in the event of strong harmonics caused by frequency converter operation. Rated DT Installation kit PS* uninter(IP40) rupted consisting of: current lockable handle Iu and three terminal covers for the line side Weight DT Basic switch per PU version approx. without handle PS* Weight DT Installation kit PS* per PU (IP40) approx. consisting of: lockable handle and three terminal covers for the line side Black handle EMERGENCYSTOP Red handle Order No. A Weight per PU approx. kg Order No. kg Order No. kg 3-pole, kit for mounting in control cabinet side panel 63 80 125 160 B B B B 3KX3 516–2AA 3KX3 516–2AA 3KX3 536–2AA 3KX3 536–2AA 1 unit 1 unit 1 unit 1 unit 0.591 0.591 0.843 0.843 } } } } 3KA50 30–1AE01 3KA51 30–1AE01 3KA52 30–1AE01 3KA53 30–1AE01 1 unit 1 unit 1 unit 1 unit 0.946 0.918 1.880 2.020 B B B B 3KX3 516–2BA 3KX3 516–2BA 3KX3 536–2BA 3KX3 536–2BA 1 unit 1 unit 1 unit 1 unit 0.584 0.584 0.860 0.860 250 400 630 B B B 3KX3 556–2AA 3KX3 556–2AA 3KX3 556–2AA 1 unit 1 unit 1 unit 1.560 } 1.560 } 1.560 } 3KA55 30–1AE01 3KA57 30–1AE01 3KA58 30–1AE01 1 unit 1 unit 1 unit 4.510 B 4.630 B 5.150 B 3KX3 556–2BA 3KX3 556–2BA 3KX3 556–2BA 1 unit 1 unit 1 unit 1.590 1.590 1.590 3KA53 30–1AE01 with 3KX3 536–2AA * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/31 6 SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A Base mounting All switch disconnectors in degree of protection IP00 with high-speed closing and opening Conductor connecting screws are generally included in the scope of delivery Rated uninterrupted current Iu DT A Complete version with black handle PS* Order No. Weight DT per PU approx. Basic switch version without handle kg Order No. PS* Weight DT per PU approx. EMERGENCYSTOP red handle + coupling socket kg Order No. PS* Weight per PU approx. kg 3-pole, operating mechanism and actuation from the front Direct operating mechanism 250 B 3KE42 30–0BA 1 unit 4.210 B 3KE42 30–0AA 1 unit 3.870 8UC93 71 B +3KX2 210–0H 1 unit 1 unit 0.146 0.236 400 B 3KE43 30–0BA 1 unit 4.170 B 3KE43 30–0AA 1 unit 3.870 B 8UC93 71 B +3KX2 210–0H 1 unit 1 unit 0.146 0.236 630 C 3KE44 30–0BA 1 unit 7.180 B 3KE44 30–0AA 1 unit 6.910 B 8UC93 75 B +3KX2 210–0H 1 unit 1 unit 0.165 0.236 1000 C 3KE45 30–0BA 1 unit 7.830 C 3KE45 30–0AA 1 unit 7.420 B 8UC93 75 B +3KX2 210–0H 1 unit 1 unit 0.165 0.236 Rated uninterrupted current Iu DT Complete PS* version with 8UC6 door-coupling rotary operating mechanism (black handle) Weight DT per PU approx. Basic switch version without handle Order No. kg Order No. 3KE43 30–0BA A 6 PS* Weight DT per PU approx. 8UC6 EMERPS* GENCY-STOP door-coupling rotary operating mechanism (red handle, yellow indicator plate) Weight per PU approx. kg Order No. kg 3-pole, operating mechanism and actuation from the front Door-coupling rotary operating mechanism (lockable) 6/32 250 B 3KE42 30–0EA 1 unit 5.030 B 3KE42 30–0AA 1 unit 3.870 } 8UC63 24–3BB44 1 unit 1.170 400 B 3KE43 30–0EA 1 unit 5.040 B 3KE43 30–0AA 1 unit 3.870 } 8UC63 24–3BB44 1 unit 1.170 630 B 3KE44 30–0EA 1 unit 7.880 B 3KE44 30–0AA 1 unit 6.910 } 8UC64 24–3BB44 1 unit 1.180 1000 B 3KE45 30–0EA 1 unit 8.530 C 3KE45 30–0AA 1 unit 7.420 } 8UC64 24–3BB44 1 unit 1.180 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A Base mounting 3-pole, rear operating mechanism and actuation Rated uninterrupted current Iu DT A Basic switch version without handle PS* Order No. Weight DT per PU approx. Handle (black) + masking plate + display plate (silver) kg Order No. PS* Weight DT per PU approx. EMERGENCYSTOP handle red + masking plate + display plate (yellow) kg Order No. PS* Weight per PU approx. kg Direct operating mechanism 250 B 3KE42 30–0CA 1 unit 5.300 B A A 400 B 3KE43 30–0CA 1 unit 5.030 B A 630 C 3KE44 30–0CA 1 unit 7.390 C A 1000 C 3KE45 30–0CA 1 unit 7.990 C A A A A 8UC93 70 +8UB95 30 1 unit 1 unit 0.128 B 0.028 A 8UC93 71 +8UB95 30 1 unit 1 unit 0.146 0.028 +8UC96 31–0B 1 unit 0.011 A +8UC96 33–0B 1 unit 0.011 8UC93 70 +8UB95 30 1 unit 1 unit 0.128 B 0.028 A 8UC93 71 +8UB95 30 1 unit 1 unit 0.146 0.028 +8UC96 31–0B 1 unit 0.011 A +8UC96 33–0B 1 unit 0.011 8UC93 74 +8UB95 30 1 unit 1 unit 0.145 B 0.028 A 8UC93 75 +8UB95 30 1 unit 1 unit 0.165 0.028 +8UC96 31–0B 1 unit 0.011 A +8UC96 33–0B 1 unit 0.011 8UC93 74 +8UB95 30 1 unit 1 unit 0.145 B 0.028 A 8UC93 75 +8UB95 30 1 unit 1 unit 0.165 0.028 +8UC96 31–0B 1 unit 0.011 A +8UC96 33–0B 1 unit 0.011 8UC93 70 +8UC95 63 1 unit 1 unit 0.128 B 0.271 B 8UC93 71 +8UC95 63 1 unit 1 unit 0.146 0.271 +8UC96 31–0B 1 unit 0.011 A +8UC96 33–0B 1 unit 0.011 8UC93 70 +8UC95 63 1 unit 1 unit 0.128 B 0.271 B 8UC93 71 +8UC95 63 1 unit 1 unit 0.146 0.271 +8UC96 31–0B 1 unit 0.011 A +8UC96 33–0B 1 unit 0.011 8UC93 74 +8UC95 63 1 unit 1 unit 0.145 B 0.271 B 8UC93 75 +8UC95 63 1 unit 1 unit 0.165 0.271 +8UC96 31–0B 1 unit 0.011 A +8UC96 33–0B 1 unit 0.011 8UC93 74 +8UC95 63 1 unit 1 unit 0.145 B 0.271 B 8UC93 75 +8UC95 63 1 unit 1 unit 0.165 0.271 +8UC96 31–0B 1 unit 0.011 A +8UC96 33–0B 1 unit 0.011 Direct operating mechanism (lockable) 250 B 3KE42 30–0CA 1 unit 5.300 B B 400 B 3KE43 30–0CA 1 unit 5.030 B B 630 C 3KE44 30–0CA 1 unit 7.390 C B 1000 C 3KE45 30–0CA 1 unit 7.990 C B A A A A 3-pole, rear rotary operating mechanism (lockable) Rated uninterrupted current Iu DT A Basic switch version without handle PS* Order No. Weight DT per PU approx. 8UC6 door-cou- PS* pling rotary operating mechanism (black handle) Weight DT per PU approx. 8UC6 EMERGENCY-STOP door-coupling rotary operating mechanism (red handle, yellow indicator plate) kg Order No. kg Order No. PS* Weight per PU approx. kg Door-coupling rotary operating mechanism (lockable) 250 B 3KE42 30–0CA 1 unit 5.300 B 8UC63 14–1BB44 1 unit 1.150 } 8UC63 24–3BB44 1 unit 1.170 400 B 3KE43 30–0CA 1 unit 5.030 B 8UC63 14–1BB44 1 unit 1.150 } 8UC63 24–3BB44 1 unit 1.170 630 C 3KE44 30–0CA 1 unit 7.390 } 8UC64 14–1BB44 1 unit 1.170 } 8UC64 24–3BB44 1 unit 1.180 1000 C 3KE45 30–0CA 1 unit 7.990 } 8UC64 14–1BB44 1 unit 1.170 } 8UC64 24–3BB44 1 unit 1.180 * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/33 6 SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A Molded-plastic enclosure ■ Benefits ■ Functions • Lockable with 3 padlocks • Generous terminal chamber • Degree of protection IP65 • Maintenance-free • Easy mounting The concept and mechanical construction of these switches are designed for reliable function even under the harshest conditions. In emergencies, every second counts, and our switches allow immediate isolation. Our enclosed main control and EMERGENCY-STOP switches can be locked with up to three padlocks and are available in two ergonomically designed versions from 16 A to 1000 A. ■ Area of application Our main control and EMERGENCY-STOP switches provide absolute safety, even during maintenance and repair work. Allround safety for people and machines. With their high degree of protection IP65, they can even withstand dust and water jets, providing unparalleled safety in the building and industrial installations as well as the food and chemical industry. Even with the enclosure open, they meet Safety Class 2. IP20 is the minimum! ■ Selection and ordering data Main Auxiliary P/AC-23 A contact contacts at at elements 380 to 400 V 660/690 V kW kW Iu Conductor cross-section for main conductor/PEN A mm2 DT PS* Order No. Weight per PU approx. kg Main control switch complete with rotary operating mechanism, black1) 3 6 8HP27.. – 65 80 132 110 150 220 125 160 250 35/352) 120/702) 150/702) C C C 8HP27 07 8HP27 11 8HP27 12 1 unit 1 unit 1 unit 5.240 8.030 12.200 200 350 315 375 375 315 400 630 8003) 2 × 150 or 1 × 240/120 2 × 240/120 2 × 240/240 C C C 8HP27 17 8HP27 18 8HP27 38 1 unit 1 unit 1 unit 12.300 13.000 14.200 EMERGENCY-STOP switch complete with rotary operating mechanism, red/yellow1) 3 – 65 80 132 110 150 220 125 160 250 35/352) 120/702) 150/70 2) C C C 8HP27 47 8HP27 48 8HP27 61 1 unit 1 unit 1 unit 5.210 7.990 12.300 200 350 315 375 375 315 400 630 800 3) 2 × 150 or 1 × 240/120 2 × 240/120 2 × 240/240 C C C 8HP27 62 8HP27 63 8HP27 58 1 unit 1 unit 1 unit 12.300 12.800 14.300 1) With PE/ground or neutral terminal. 2) For a fifth conductor, the same terminal can be fitted additionally. 3) At ambient temperature up to 35 °C. 6/34 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A Accessories ■ Selection and ordering data DT 3KA50 30/ 3KA51 30 PS* Order No. Terminal cover (1 set = 6 units) for 3-pole devices 3KX3 552–3DA01 8UC62 12–1BB20 3KX3 516-1AA 3KX3 552–3DA01 Weight per PU approx. DT kg PS* Order No. 0.077 } 1 set 3KA50 40/ 3KA51 40/ 3KA52/ 3KA53 } 3KA52 3KX3 552–3DA01 3KA53 3KX3 553–3DA01 Weight per PU approx. kg 1 set 0.077 1 set 0.147 1 set 0.102 (1 set = 8 units) for 4-pole devices B 3KX3 552–3DB01 1 set 0.102 B B 3KA52 3KX3 552–3DB01 3KA53 3KX3 553–3DB01 1 set 0.170 Door-coupling rotary operating mechanism IP65 black handle, shaft 300 mm } 8UC61 11–1BB10 1 unit 0.347 } 8UC62 12–1BB20 1 unit 0.404 Door-coupling rotary operating mechanism IP65 EMERGENCY-STOP (yellow/red), shaft 300 mm } 8UC61 21–3BB10 1 unit 0.353 } 8UC62 22–3BB20 1 unit 0.426 Operating mechanism for fixed mounting black handle, shaft 250 mm } 3KX3 516–1AA 1 unit 0.088 } 3KX3 536–1AA 1 unit 0.155 Extension shaft 300 mm long B 8UC60 31 1 unit 0.068 B 8UC60 32 1 unit 0.132 Extension shaft 600 mm long B 8UC60 81 1 unit 0.136 B 8UC60 82 1 unit 0.265 Shaft connection piece B 8UC60 21 1 unit 0.031 B 8UC60 22 1 unit 0.023 Auxiliary switch 1 NO + 1 NC1) A 3SB14 00–0A 1 unit 0.019 A 3SB14 00–0A 1 unit 0.019 3KX3 552-3EA01 1 unit 0.019 Auxiliary switch 20 ms leading switchoff B - DT 3KA55/ 3KA57/ 3KA58 PS* Order No. Weight per PU approx. kg } 3KX3 557–3DA01 1 set 0.277 (1 set = 8 units) for 4-pole devices B 3KX3 557–3DB01 1 set 0.362 Door-coupling rotary operating mechanism IP65 black handle, shaft 300 mm } 8UC63 13–1BB30 1 unit 0.973 Door-coupling rotary operating mechanism IP65 EMERGENCY-STOP (yellow/red), shaft 300 mm } 8UC63 23–3BB30 1 unit 0.999 Operating mechanism for fixed mounting black handle, shaft 250 mm } 3KX3 176–1E 1 unit 0.285 Extension shaft 300 mm long C 8UC60 33 1 unit 0.217 Extension shaft 600 mm long B 8UC60 83 1 unit 0.430 Shaft connection piece B 8UC60 23 1 unit 0.085 Auxiliary switch 1 NO + 1 NC1) A 3SB14 00–0A 1 unit 0.019 3KX3 552-3EA01 1 unit 0.019 Terminal cover (1 set = 6 units) for 3-pole devices 3KX3 176-1E Auxiliary switch 20 ms leading switchoff 1) For further 3SB14 00–0 switching elements with other contact types, see “Pushbuttons and Indicator lights". * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/35 6 SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A Accessories DT 3KE42/3KE43 PS* Order No. Weight DT per PU approx. 3KE44/3KE45 kg Order No. PS* Weight per PU approx. kg Changeover switches Changeover switch with interruption Switch I ON – Switch II OFF Switch I OFF – Switch II OFF Switch I OFF – Switch II ON 3KX2 210–0D B 3KX2 210–0D 1 unit 2.440 B 3KX2 210–0D 1 unit 2.440 Door-coupling rotary operating mechanism IP65 twin handle (black), shaft 300 mm B 8UC65 14–1BF44 1 unit 1.180 B 8UC65 14–1BF44 1 unit 1.180 Direct operating mechanism twin handle (black) for fixed mounting C 8UC93 81 1 unit 0.264 C 8UC93 81 1 unit 0.264 B 3KX2 210–0E 1 unit 2.440 B 3KX2 210–0E 1 unit 2.440 Door-coupling rotary operating mechanism IP65 twin handle (black), shaft 300 mm B 8UC65 14–1FG44 1 unit 1.130 B 8UC65 14–1FG44 1 unit 1.130 Direct operating mechanism twin handle (black) for fixed mounting C 8UC93 81 1 unit 0.264 C 8UC93 81 1 unit 0.264 C 3KX2 250–1A 1 unit 0.750 C 3KX2 250–1A 1 unit 0.750 B 8UC65 14–1BB44 1 unit 1.260 B 8UC65 14–1BB44 1 unit 1.260 EMERGENCY-STOP door-coupling rotary B operating mechanism IP65 twin handle (red), shaft 300 mm 8UC65 24–3BB44 1 unit 1.220 B 8UC65 24–3BB44 1 unit 1.220 C 8UC93 81 1 unit 0.264 C 8UC93 81 1 unit 0.264 } 3KX3 557–3DA01 1 set 0.277 – Changeover switch without interruption Switch I ON – Switch II OFF Switch I ON – Switch II ON Switch I OFF – Switch II ON 8UC65 14–1BB44 Parallel switches 3KX3 557–3DA01 Switch I ON Switch I OFF – – Switch II ON Switch II OFF Door-coupling rotary operating mechanism IP65 twin handle (black), shaft 300 mm 6 Direct operating mechanism twin handle (black) for fixed mounting 3KX2 231–1A Further accessories Terminal cover (1 set = 6 units) Terminal cover (top and bottom) 3K42 232–0A 3K42 204–0A 6/36 3KX2 252–0C 1 unit 0.424 Door-coupling rotary operating mechanism IP65 black handle, shaft 300 mm B 8UC63 14–1BB44 1 unit 1.150 } 8UC64 14–1BB44 1 unit 1.170 Door-coupling rotary operating mechanism IP65 EMERGENCY-STOP (yellow/red), shaft 300 mm } 8UC63 24–3BB44 1 unit 1.170 } 8UC64 24–3BB44 1 unit 1.180 Extension shaft 300 mm long B 8UC60 34 1 unit 0.315 B 8UC60 34 1 unit 0.315 Extension shaft 600 mm long B 8UC60 84 1 unit 0.640 B 8UC60 84 1 unit 0.640 Auxiliary switch 1 NO + 1 NC (complete mounting kit) B 3KX2 231–1A 1 unit 0.049 B 3KX2 231–1A 1 unit 0.049 Grounding bracket B 3KX2 252–1A 1 unit 0.049 B 3KX2 252–1A 1 unit 0.049 Arc chute (spare part with 3 arc-splitter assemblies) B 3KY2 202–0B 1 unit 0.640 B 3KY2 232–0A 1 unit 1.040 Arcing contacts (spare part with 3 fixed and 3 movable contacts) B 3KY2 204–0A 1 set 0.202 B 3KY2 234–0A 1 set 0.105 Siemens LV 30 · 2004 B – * This quantity or a multiple thereof can be ordered. SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A Project planning aids ■ Dimension drawings 3KA50, 63 A, 3KA51, 80 A, 3-pole 3KA50 and 3KA51: dimension drawing for 4-pole version corresponds to 3KA52 without shaft, without operating mechanism 43,5 4,5 15 3KA50, 63 A, 3KA51, 80 A, 3-pole 3KA50 and 3KA51: dimension drawing for 4-pole version corresponds to 3KA52 with shaft and 8UC6 operating mechanism 80 36 90 90 30 105 1,5...4 NSE00305 42 - 50 6 NSE00306a 6,6 4,5 25 22,5 32,5 120 23 75 66 65 Æ 4,5 a M6x20 2 150 3KA50, 3KA51 NSE00291 Shaft (profile) R2 Engaged length: min. 70 mm max. 150 mm 6-0,1 a Shaft length max. 380 300; unchanged shaft from 8UC61 min. 175 175–80; shortened shaft fr. 8UC61 ≥ 175 ... ≤ 380 a–80 3KA52, 125 A 3KA53, 160 A 3KA50, 3KA51, 4-pole without shaft, without operating mechanism 85 63 25 55 g c 60 91 i 42 - 50 8 NSE00309 Fourth pole 3KX3 523–0AA for 3KA53 NSE00308b d 143 5 e 90 185 l 38 1,5...4 110 h 100 125 35 15 3KA52, 125 A 3KA53, 160 A 3KA50, 3KA51, 4-pole with shaft and 8UC6 operating mechanism -0,1 215 30 107 25 65 a 11 min. 165 165–50; shortened shaft fr. 8UC62 Type c d e g h I l N 3KA52 3KA53 15 20 M 6 × 20 M 8 × 25 37 39 42 39.5 91 105 3 3.5 ∅ 6.6 ∅9 106 125 4th pole 15 M 6 × 20 – 48 3 ∅ 6.6 106 16 b NSE00313 91 140 63 - 65 10 c 3 130 135 160 300; unchanged shaft from 8UC62 3KA55, 250 A, 3KA57, 400 A, 3KA58, 630 A with shaft and 8UC6 operating mechanism 41 86 Shaft length max. 350 c 3KA55, 250 A, 3KA57, 400 A without shaft, without operating mechanism 26,5 a ≥ 165 ... ≤ 350 a–50 h n NSE00279b l 65 6 16,5 N 4,5 a 3KA52, 3KA53 NSE00281 Shaft (profile) Engaged length: R2 min. 90 mm max. 143 mm 8 46 N 75 66 1,5...4 5,5 100 88 88 a 132 3KA58, 630 A without shaft, without operating mechanism 86 107 30 3KA58 *) a 65 b 11 130 180 150 7 NSE00314a 20 17 100 240 230–35; shortened shaft fr. 8UC63 a–35 55,5 Shaft (profile) Engaged length: min. 170 mm max. 205 mm R2 10 -0,1 16 Shaft length 300; unchanged shaft from 8UC63 Fourth pole 3KX3 553–0AA for 3KA55, 3KA57, 3KA58 NSE00283 c 41 26,5 207 NSE00285a N 3 N 128 207 Type a b c 3KA55, 3KA57 3KA58 40 4 M 10 × 30 38 6 M 10 × 35 4th pole 80 4 M 10 × 30 293 25 53 100 135 160 7 NSE00312a 20 17 100 240 11 3KA55, 3KA57 a NSE00283 Shaft (profile) max. 335 Engaged length: R2 min. 170 mm min. 230 max. 205 mm 10 -0,1 ≥ 230 ... ≤ 335 c Siemens LV 30 · 2004 6/37 SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A Project planning aids 3KE4 Front operating mechanism with handle o 254 e 46,5 m 92 32 1 90° 7 l l NSE00318a 128 152 k f c 11 40 19 v 5 7 p1 NSE00319a 195 5 Not to be used as an operating mechanism! n1 e 3KX2 210–0H Coupling socket 8 g 29 12 111 68 97 NSE00320 u Type b c d e f g h h1 k l 3KE42 3KE43 3KE44 3KE45 155 155 170 170 170 170 192 192 140 140 155 155 25 25 40 40 200 200 278 290 40 47 55 65 60 60 65 68 92 92 97 100 175 175 238 250 M10 × 30 194 M10 × 30 194 M12 × 35 209 M12 × 50 209 m s 100 209 m1 n n1 o p p1 s t u v w w1 x 194 194 208 208 129 129 144 144 121 121 136 136 4 4 5 8 150 150 161 161 182 182 193 193 15 15 23 23 – – 3.5 3.5 105 105 121 121 140 140 200 200 170 170 172 172 172 172 172 172 M10 × 18 50 M10 × 18 50 M10 × 18 – M12 × 25 – y z 50 50 – – 88 100 3KE4. 30–0EA with shaft and 8UC6 operating mechanism NSE00321 Ø 63 to 65 q 1,5...4 r r Shaft length max. 433 300; unchanged shaft from 8UC63 140 q min. 200 67; shortened shaft from 8UC63 140 ≥ 200 ... ≤ 433 r–133 140 max. 433 300; unchanged shaft from 8UC64 200 min. 210 77; shortened shaft from 8UC64 200 ≥ 210 ... ≤ 433 r–133 200 88 3KX2 250–1A operating linkage 212 e Type 3KE42, 3KE43 3KE44, 3KE45 Ø 5,5 3KX2 210 changeover operating mechanism 12 12 72 40 209 248,5 44 25 f 212 c a 7 58 NSE00323 152 57 b 122 90 6 14,5 12 w1 20 12 4,5 34,5 c 152 k f 3KX2 210-0H 12 24 22,5 y x y 90° 63,5 z h m1 b d This space must remain free (arc ejection) t 8 Ø7 x w 128 g This space must remain free (arc ejection) z 32 14,5 187 p 133 t b d n 3KE4 Rear rotary operating mechanism without handle d NSE00322 Version for type a B c d e f with interruption 3KE42, 3KE43 3KE44 3KE45 352 367 367 140 155 155 427 442 442 92.5 92.5 92.5 115 115 115 45 45 55 without 3KE42, 3KE43 interruption 3KE44 3KE45 352 367 367 140 155 155 417 432 432 74.5 74.5 74.5 97 97 97 35 35 35 6/38 Siemens LV 30 · 2004 *) see page 6/37: According to the label on the switch and the operating instructions for 3K.55, 57, 58, engaged lengths of min. 160 mm to max. 207 mm are possible. In the catalog, however, these specifications have been limited to min. 170 mm to max. 205 mm. SENTRIC Switch Disconnectors SENTRIC K Switch Disconnectors from 63 A to 1000 A Project planning aids ■ Circuit diagrams Circuit diagram for SENTRIC KA Circuit diagram for changeover switch with interruption L1 I NSE00188 L2 L3 L1 (for 3KA50 and 3KA51, only one auxiliary switch possible; 4th pole as main contact possible) Circuit diagram for 3KE II L2 L3 I 0 II Circuit diagram for 3KE and SENTRIC KA (auxiliary switch not included in scope of supply) Use for DC voltage at DC-23A 440 V 6 Siemens LV 30 · 2004 6/39 SENTRIC NP Fuse Switch Disconnectors General data ■ Area of application ■ Design SENTRIC 3NP4 and 3NP5 fuse switch disconnectors are switching devices for the occasional manual switching/isolating of loads and distribution boards. They are capable of switching on, carrying and switching off the specified rated current (including a certain overload). With SENTRIC 3NP4 and 3NP5 fuse switch disconnectors, downstream electrical loads are safely isolated from the supply, disconnecting all poles and under load. The SENTRIC 3NP4 and 3NP5 fuse switch disconnectors are ideally suited to surface mounting and flush mounting in switchboards (e.g. ALPHA, SIKUS), meter cabinets (e.g. ALPHA 400ZS), and molded-plastic distribution systems such as SENTRIC 8HP. The possibility of mounting on a wide variety of busbar systems allows a broad scope of application in control cabinet manufacture and control engineering. The SENTRIC 3NP4 NH 0002) and NH 00 sizes can be snapped onto a 35 mm standard mounting rail and are ideal for use in combination with other switching devices, for example in capacitor modules for reactive power compensation. SENTRIC 3NP4 and 3NP5 fuse switch disconnectors 6 In conjunction with semiconductor protection fuses (e.g. SITOR), these are used for the effective protection of frequency converters and soft starters. SENTRIC NP fuse switch disconnectors The SENTRIC 3NP4 and 3NP5 fuse switch disconnectors consist of a fuse base and a removable fuse carrier with inspection window and measurement function window. Lyre-shaped contacts, arc chutes and connection pieces are integrated in the base. The fuse carrier holds the fuse links or isolating links. The links can be replaced without the use of tools. The three conducting paths in the base and the fuse links in the fuse carrier are separated by partitions, which overlap when the unit is opened and closed. This powerful intrinsic protection is known as "full compartmentalization", and efficiently and effectively prevents flashover between the phases. The SENTRIC 3NP5 fuse switch disconnectors are additionally equipped with locating springs at the side of the base. These allow "high-speed closing" of the device regardless of the actuating speed of the operator. LV HRC fuses of sizes NH 000 to NH 3 according to IEC 602692-1 and DIN VDE 43620 are used in the SENTRIC 3NP4 and 3NP5 fuse switch disconnectors. SITOR semiconductor protection fuses can also be used. Further information is provided in the operating instructions for the SENTRIC 3NP4 and 3NP5 fuse switch disconnectors. Auxiliary switches The SENTRIC 3NP4 and 3NP5 fuse switch disconnectors can be retrofitted with auxiliary switches for signaling the switching position of the fuse carrier. One switching element (1 CO) can be fitted to size NH 000 SENTRIC 3NP4 fuse switch disconnectors, or two switching elements (1 CO) to sizes NH 00 to NH 3. The SENTRIC 3NP5 fuse switch disconnectors can optionally be supplied with a 2-pole auxiliary switch (1 NO + 1 NC). The variant with fuse monitoring is always equipped with this auxiliary switch. 3NP40 10 3NP40 70 3NP52 with open fuse carrier The SENTRIC 3NP4 and 3NP5 fuse switch disconnectors are suitable for use in any climate and comply with standards IEC 60947-1, IEC 60947-3 and DIN VDE 0660 Part 107. The SENTRIC 3NP5 series and the 3NP40 1 and 3NP40 7 variants are available as tin-plated version for use in extremely sulfurous atmospheres (available on request). In addition, the SENTRIC 3NP5 fuse switch disconnector series complies with BS 5419 and also has marine approval.1) All SENTRIC 3NP4 and 3NP5 fuse switch disconnectors can be sealed, either as standard or using accessories. 1) Use only approved fuse links. 2) Corresponds to fuse sizes NH 000 (NH 00C) or NH 00 with reduced dimensions; maximum width 21 mm to IEC 60269-2-1 and DIN VDE 43620. 6/40 Siemens LV 30 · 2004 SENTRIC NP Fuse Switch Disconnectors General data ■ Functions Fuse monitoring with SIRIUS circuit-breakers Electronic fuse monitoring (EFM) To allow fuse monitoring a SIRIUS circuit-breaker is fitted in the factory, permanently wired and mounted on the fuse carrier of the SENTRIC 3NP4 and 3NP5 fuse switch disconnectors. With electronic fuse monitoring, the fuse monitoring system is fitted in the factory, permanently wired and mounted on the fuse carrier of the SENTRIC 3NP5 fuse switch disconnectors. When the fuse carrier is closed, the three conducting paths of the SIRIUS circuit-breaker are switchable in parallel with the fuse links being monitored. When the fuse carrier is open, all main conducting paths of the circuit-breaker are de-energized. The monitoring system works whether or not a load is present. The failure of a fuse can be signaled to a control room by a group fault signal via integrated auxiliary switches (2 NO + 1 NC) or used to isolate the load via a contactor, for example. The internal resistance of the circuit-breaker is sufficiently high so that it does not impair the protection function of the monitored fuse links. The actuation of the auxiliary switches depends on the version of the monitoring system. Version "A" stands for "open-circuit principle", and version "R" for "closed-circuit principle" (see block diagram). If a fuse blows, the circuit-breaker trips. The auxiliary switch of the circuit-breaker can be used for signaling or to open the main circuit, for example via a contactor. For size NH 00 SENTRIC 3NP4 fuse switch disconnectors the signal lead must be ordered separately. For sizes NH 1 to NH 3 the connection is via flat connectors. The signal lead for SENTRIC 3NP5 fuse switch disconnectors is enclosed with the unit as ordered, including connector. Fuse monitoring by SIRIUS circuit-breakers is not permissible for circuit-breaker controlled feeders subject to reverse feed of more than DC 220 V in the event of a fault. In the event of a fuse rupture, a flashing signal on the device indicates a general malfunction with a green LED and the position of the failed fuse is indicated by a red LED. If more than one device is used, it is easier to identify the relevant feeder. The EFM automatically returns to the standby position as soon as the defective fuses have been replaced. Visually this status is indicated by the status display (green LED). The electronic fuse monitoring system is also suitable for use in industrial networks that are especially subject to the effect of harmonics. With parallel cables and meshed systems, a voltage difference of more than 24 V is necessary at the switch in order to cause tripping. 6 Siemens LV 30 · 2004 6/41 SENTRIC NP Fuse Switch Disconnectors General data ■ Technical specifications Standards IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Type 3NP40 1 Rated uninterrupted current Iu For fuse links acc. to DIN 43620 Conventional thermal current Ith Rated operating voltage Ue AC 50 Hz/60 Hz DC Rated insulation voltage Ui Rated impulse withstand voltage Uimp 3NP40 7 3NP42 7 3NP43 7 3NP44 7 A 1601) Size 00C/000 160 00 250 1 and 0 400 2 and 1 630 3 and 2 A 1601) 160 250 400 630 V 690 V 220 (3 conducting paths series-connected) 690 440 (2 conducting paths series-connected) V 690 690 8003) 8003) 8003) 6 6 6 6 00/160 50 1/250 50 2/400 50 3/630 50 158 551 1515 4340 15 25 35 55 00/160 50 1/250 50 2/400 50 3/630 50 15 25 35 55 00 1 2 3 A (rms value) 800 (p.f. = 0.45) 800 2000 3200 5040 A 160 A 100 160 100 250 250 400 400 630 630 00 1 2 3 A (rms value) 320 (p.f. = 0.45) 320 750 1200 1890 A 160 A 100 A 40 160 100 40 250 250 – 400 400 – 630 630 – 00 1 2 3 200/240 (p.f. = 0.45/0.95) 375 600 945 160 50 25 250 – – 400 – – 630 – – 00 1 2 3 80/160 – – 250 – 400 – 630 kV 6 Rated conditional short-circuit current with fuses (on rapid closing) with fuse links Rated current at AC 400 V (690 V) Maximum permissible let-through I2t value Permissible let-through current of the fuse Size/A 000/100 (35) kA (rms value) 50 (50) kA2s 56 (7.8) kA (peak value) 11 (5) Short-circuit strength with fuses (with closed disconnector) with fuse links Rated current at 690 V Permissible let-through current of the fuse Size/A 000/100 kA (rms value) 100 kA (peak value) 15 Rated making and switching capacity (Feed-in from top or bottom) 6 at AC 400 V, with fuse links or isolating links Rated breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21B, AC-22B AC-23B at AC 500 V, with fuse links or isolating links Rated breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21B AC-22B AC-23B at AC 690 V, with fuse links or isolating links Rated breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21B AC-22B AC-23B at DC 220 V/240 V, with fuse links2)4)5) or isolating links Rated operating current Ie with 220 V DC-23B/DC-21B 440 V DC-21B Size 000 Size 000 Size 000 A (rms value) 200/240 (p.f. = 0.45/0.95) A 160 A 50 A 25 Size 000 A 80/160 A – 1) 125/160 A only with 3NY1 236 line-side terminals and with 21 mm wide 3NY1 822 (125 A) and 3NY1 824 (160 A) fuse links; see Accessories. 2) For no-load switching (AC-20 B, DC-20 B) DC voltages up to DC 690 V can be applied. 3) For safety monitoring max. 690 V. 4) With pollution degree 2, the disconnectors up to 1000 V AC-20 B, DC-20 B (no-load switching) can be used. 5) Conducting paths in series: 3 with 3NP40; 2 with 3NP42, 3NP43 and 3NP44. 6/42 Siemens LV 30 · 2004 SENTRIC NP Fuse Switch Disconnectors General data Standards IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Type 3NP40 1 3NP40 7 3NP42 7 3NP43 7 3NP44 7 Capacitance switching capacity at AC 400 V Reactive power Rated current In kvar 50 A 72 50 72 – – – – – – at AC 525 V Reactive power Rated current In kvar 50 A 55 50 55 – – – – – – 1000 1000 Permissible ambient temperature Mechanical endurance °C –25 ... +551) in operation, –50 ... +80 when stored Oper. cycles 2000 2000 1600 Degree of protection (with respect to the operator side) Without molded-plastic masking frame/cable lug cover IP00 (3NP40 with box terminal and properly connected conductors: IP20) With molded-plastic masking frame/cable lug cover IP30 (switch closed), IP20 (switch open) Power loss of the switch at Ith (plus power loss of the fuse links) Without busbar adapter W 4.5 (at 100 A) 10 15 30 47 With busbar adapter W 8.5 (at 100 A) 20 47 83 127 Main conductor connection Flat connector for cable lug, max. conductor cross-section (stranded) mm2 – up to 2 × 70 (M 8) up to 150 (M 10) up to 240 (M 10) up to 2 × 240 (M 12) Box terminal/connection terminal (finely stranded with end sleeve) mm2 1.5–50 (35) 2.5–70 (50) 70–150 120–240 150–300 Conductor bar (width x thickness) mm – 22 × 5 22–30 × 5–10 22–30 × 5–10 25–40 × 5–10 Laminated Cu strips, not perforated, in terminals (width × thickness) mm 8 × 8 up to 9 × 8 up to 16 × 8 up to 20 × 10 up to 24 × 10 For flat connector Nm – 10–12 25 25 30 With SIGUT box terminal/connection terminal Nm 3–3.5 8–10 6 8 8 Tightening torque for terminal screws Auxiliary switch 1 CO (accessory) 3NY3 035 AC 50 Hz/60 Hz to 230 V rated operating current Ie with AC-14 A 0.25 (Ith = 5 A), at DC 24 V: Ie = 0.45 A; flat connector to DIN 46244: A 2.8 × 0.5 3NY3 030 AC 50 Hz/60 Hz to 230 V rated operating current Ie with AC-13 A 0.1 (Ith = 0.1 A); plug-in sleeve to DIN 46245: A 2.8 – 1 Permissible mounting position Vertical or horizontal (no reduction in specified switching capacity) 1) Only with isolating links; otherwise note the information from the fuse manufacturer. Siemens LV 30 · 2004 6/43 6 SENTRIC NP Fuse Switch Disconnectors General data Standards IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Type 3NP50 Rated uninterrupted current Iu For fuse links acc. to DIN 43620 (The use of semiconductor protection fuse links requires a reduction of rated current – see Page 13/54 and Catalog DA 94.1) Continuous thermal current Ith Rated operating voltage Ue AC 50 Hz/60 Hz DC A 160 Size 00 A 160 3NP52 3NP53 3NP54 250 1 and 0 400 2 and 1 630 3 and 2 250 400 630 V 690 V 440 (3 conducting paths series-connected), 220 (2 conducting paths series-connected and with fuse monitoring through 3RV) V 6901) Rated insulation voltage Ui Rated impulse withstand voltage Uimp kV 6 6901) 6901) 6901) 6 6 6 1/250 50 2/400 50 3/630 50 25 40 50 1/250 100 2/400 50 3/630 50 Rated conditional short-circuit current with fuses (on rapid closing) with fuse links Rated current at AC 500 V Size/A 00/160 kA (rms value) 50 Permissible let-through current of the fuses kA (peak value) 15 Short-circuit strength with fuses (with closed switch) with fuse links Rated current at AC 500 V Size/A 00/160 kA (rms value) 100 Maximum permissible let-through I2t value 6 kA2s 223 780 2150 5400 Permissible let-through current of the fuses kA (peak value) 23 32 40 60 Rated short-circuit making capacity with isolating links2) at AC 500 V Size 00 kA (peak value) 6 1 17 2 17 3 17 Rated making and switching (feed-in from top or bottom)3) capacity2) at AC 400 V, with fuse links Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21B, AC-22B, AC-23B Size 00 A (rms value) 1600 A 160 1 2500 250 0 1600 160 2 4000 400 1 2500 250 3 5040 630 2 4000 400 at AC 500 V, with fuse links Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21B, AC-22B, AC-23B A (rms value) 1300 A 160 2500 250 1600 160 4000 400 2500 250 5040 400 4000 400 A (rms value) 800 1280 1000 2520 1600 3200 2520 A 160 A 100 250 160 160 125 400 315 250 200 630 400 400 315 A 640 A 160 1000 250 640 160 1600 250 1600 250 2520 400 1600 400 at AC 690 V, with fuse links Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21B, AC-22B AC-23B at DC 220 V, with fuse links Breaking current Ic (L/R = 15 ms) Rated operating current Ie with DC-23B Switching capacity with isolating links4) (feed-in from top or bottom)4) at AC 400 V, with isolating links Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21B, AC-22B AC-23B at AC 500 V, with isolating links Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21B, AC-22B AC-23B at AC 690 V, with isolating links Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21B, AC-22B AC-23B at DC 220 V, with isolating links Breaking current Ic (L/R = 15 ms) Rated operating current Ie with DC-23B Switching capacity with horizontal mounting up to 690 V AC-22B 1) When observing pollution degree 2 (instead of 3) operation is also possible up to Ui = 1000 V. 2) Rated making and breaking current to IEC 60947-3 Rated making current I = 10 × Ie (AC-23); 3 × Ie (AC-22); 1.5 × Ie (AC-21) Rated breaking current Ie = 8 × Ie (AC-23); 3 × Ie (AC-22); 1.5 × Ie (AC-21) 6/44 Siemens LV 30 · 2004 Size 00 A (rms value) 1600 1 2500 2 2500 3 4000 250 250 400 315 630 500 2500 2500 4000 250 250 400 315 630 500 1280 1600 2520 A 160 A 100 250 160 400 200 630 315 A 640 A 160 1000 200 1600 400 1600 400 A 160 A 160 A (rms value) 1300 A 160 A 160 A (rms value) 800 No reduction in specified switching capacity (Values for AC-23B up to 690 V on request) 3) When using electronic fuse monitoring, feed-in must be from the top. 4) Insert silver-plated isolating links. SENTRIC NP Fuse Switch Disconnectors General data Type 3NP50 3NP52 3NP53 3NP54 150 216 250 361 200 220 300 330 Capacitance switching capacity at AC 400 V Reactive power Rated current In kvar 80 A 116 90 130 at AC 525 V Reactive power Rated current In kvar 100 A 110 125 137 1 °C – 25 ... + 55 in operation ), – 50 ... + 80 when stored Permissible ambient temperature Mechanical endurance Oper. cycles 1600 Degree of protection Without molded-plastic masking frame IP002) With molded-plastic masking frame and closed fuse carrier from the operator side With open fuse carrier IP30 IP10 Power loss of the switch at Ith (plus power loss of the fuse links) without busbar adapter W 7.8 (16.3)3) 7.5 15 39 mm2 2.5–120 mm 16– 22 mm2 2.5– 50 6–150 22– 30 35–120 6–240 22– 30 – 6–2 × 240 22–30 – Nm 18–22 Nm 18–22 Nm 9–11 25–30 25–30 5– 6 25–30 25–30 – 25–30 25–30 – M 10 M 10 2×M6 M 10 M 10 – M 10 M 10 – 2.5–70 25 M8 6–2 × 70 25 M 10 6–2 × 120 30 M 10 Main conductor connection Cable lug, max. conductor cross-section (stranded) Busbar Terminal clamp Tightening torque with cable lug with busbar with terminal clamp Terminal screws with cable lug with busbar with terminal clamp M8 M8 M8 6 PE/ground-conductor connection Cable lug to DIN 46234 Busbar Terminal screws mm2 – mm – – Auxiliary switch 1 NO + 1 NC (accessory) (the same voltage must be applied to the NO and NC contacts) at AC 50 Hz/60 Hz up to 400 V, rated operating current Ie at AC-12/AC-15 A A 16/6 Tab connector (DIN 46244) A 6.3–0.8 Permissible mounting position vertical or horizontal (partially reduced switching capacity with horizontal mounting) Fuse monitoring with 3RV circuit-breaker see Circuit-breakers Electronic fuse monitoring Rated voltage AC 50 Hz/60 Hz V 400 –15% to 500 V +10%, internal power supply (feed-in from top) Max. inrush current Uninterrupted current Interrupting current A 20 A 5 A 5 Contact rating VA 1000 Short-circuit strength (1 ms) Response time Temperature range (operation) Plug-in connectors/terminals A 100 s <1 °C –10 ... +75 6-pole Minimum required potential difference between upper and lower switch connections (e.g. for use in meshed networks) Signaling contact for electronic fuse monitoring V >10 2 NO + 1 NC Rated operating current Ie at 250 V, DC-13 at 240 V, AC-15 A 0.27 A 1.5 Thermal free-air rated current Ith A 5 1) When isolating links are used. When fuse links are used, the information provided by fuse manufacturer must be observed. 2) For 3NP52 with terminal clamp, degree of protection IP10. 3) With busbar adapter. Siemens LV 30 · 2004 6/45 SENTRIC NP Fuse Switch Disconnectors For power distribution ■ Selection and ordering data Rated Conductor connections (on both sides) uninter- Connection For conductor rupted cross-section current Iu mm2 A For fuse links to DIN 436201) For isolating links2) DT Size Degree of protection IP00, without fuse links, without isolating links, with terminal screws PS* Order No. Weight per PU approx. kg For surface mounting and for installation up to 160 A for snapping onto standard mounting rail 3NP40 10 1603) Box terminal 1.5–50 0004) 00 } 3NP40 10–0CH01 1 unit 0.512 160 Flat connector Box terminal up to 2 × 70 (M 8) 2.5–70 or 2 × 2.5-16 00 and 000 00 } } 3NP40 70–0CA01 3NP40 70–0CH01 1 unit 1 unit 0.749 0.800 250 Flat connector up to 150 (M 10) 1 and 0 1 and 0 } 3NP42 70–0CA01 1 unit 2.430 400 Flat connector up to 240 (M 10) 2 and 1 2 and 1 } 3NP43 70–0CA01 1 unit 3.610 630 Flat connector up to 2 × 240 (M 12) 3 and 2 3 and 2 } 3NP44 70–0CA01 1 unit 4.980 For snapping onto busbars, 40 mm busbar center-to-center distance Busbars with a width of 12 mm or 15 mm and a thickness of 5 mm or 10 mm5) • With adapter, deep, e.g. for mounting in ALPHA meter cabinets (ALPHA 400-ZS) and ALPHA switchboards (STAB/SIKUS) 1603) 160 Box terminal 1.5–50 • Connection from top 000 4) • Connect. from bottom Flat connector Box terminal 6 3NP40 70 00 A A 3NP40 15–0CK01 3NP40 15–0CJ01 1 unit 1 unit 0.952 0.970 up to 2 × 70 (M 8) • Connection from top 00 and 000 00 • Connect. from bottom A A 3NP40 75–0CE01 3NP40 75–0CF01 1 unit 1 unit 1.210 1.240 2.5–70 or 2 × 2.5-16 • Connection from top 00 and 000 00 • Connect. from bottom A A 3NP40 75–0CK01 3NP40 75–0CJ01 1 unit 1 unit 1.290 1.270 • With adapter, flat, to DIN 43620 Part 6, for general applications and ALPHA switchboards (STAB/SIKUS) 1603) 160 Box terminal 1.5–50 • Connection from top 000 4) • Connect. from bottom Flat connector Box terminal 3NP42 70 250 Flat connector 00 up to 2 × 70 (M 8) • Connection from top 00 and 000 00 and 000 • Connect. from bottom 2.5–70 or 2 × 2.5-16 • Connection from top 00 and 000 00 and 000 • Connect. from bottom up to 240 (M 10) • Connection from top or bottom 1 and 0 1 and 0 A B 3NP40 15–1CK01 3NP40 15–1CJ01 1 unit 1 unit 0.892 0.888 A A 3NP40 75–1CE01 3NP40 75–1CF01 1 unit 1 unit 1.180 1.180 A A 3NP40 75–1CK01 3NP40 75–1CJ01 1 unit 1 unit 1.260 1.210 A 3NP42 75–1CG01 1 unit 3.710 For snapping onto busbars, 60 mm busbar center-to-center distance Busbars with a width of 12 mm to 30 mm and a thickness of 5 mm or 10 mm5) flat, T and double-T profiles, and on Rittal PCS systems 1603) 160 Box terminal6) Flat connector Box 3NP40 16 250 400 630 terminal6 ) Flat connector Flat connector Flat connector 1.5–50 • Connection from top 0004) • Connect. from bottom 00 up to 2 × 70 (M 8) • Connection from top 00 and 000 00 • Connect. from bottom 2.5–70 or 2 × 2.5-16 • Connection from top 00 and 000 00 • Connect. from bottom A } 3NP40 16–1CK01 3NP40 16–1CJ01 1 unit 1 unit 0.916 0.950 A } 3NP40 76–1CE01 3NP40 76–1CF01 1 unit 1 unit 1.200 1.200 B } 3NP40 76–1CK01 3NP40 76–1CJ01 1 unit 1 unit 1.290 1.240 up to 150 (M 10) • Connection from bottom or top 1 and 0 1 and 0 } 3NP42 76–1CG01 1 unit 3.710 up to 240 (M 10) • Connection from bottom or top 2 and 1 2 and 1 } 3NP43 76–1CG01 1 unit 5.440 up to 2 × 240 (M 12) • Connection from bottom or top 3 and 2 3 and 2 } 3NP44 76–1CG01 1 unit 7.680 3NP42 76 For all fuse switch disconnectors with flat-type connection, the appropriate cable lug covers (3NY7 101 to 3NY7 141) must be used for finger-safe cover acc. to VBG4, see Accessories. 4) Corresponds to size 00 with a maximum width of 21 mm (acc. to IEC 60269-2-1 and DIN 43620). 1) Fuse links see BETA protect modular installation devices. 5) For mounting on only 5 mm thick busbars, a busbar thickness compensator is required for 3NP42 and 3NP43; see Accessories. 3NP44 can only be fitted on 10 m thick busbars. 2) Insert silver-plated isolating links. 6) No further cover is required for 3NP40 with box terminal. 3) 125/160 A only possible with 21 mm-wide 3NY1 822 (125 A) and 3NY1 824 (160 A) fuse links, see Accessories. 6/46 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC NP Fuse Switch Disconnectors For power distribution With fuse monitoring by SIRIUS circuit-breakers 1) 2) Rated Conductor connections (on both sides) uninterrupted Connection For conductor current cross-section Iu mm2 A For fuse links to DIN 436203) For isolating links4) DT Size Degree of protection IP00, PS* without fuse links, without isolating links, with terminal screws Weight per PU approx . Order No. kg For surface mounting and for installation up to 160 A also for snapping onto standard mounting rail 160 Flat connector Box terminal up to 2 × 70 (M 8) 2.5–70 or 2 × 2.5-16 00 and 000 00 A A 3NP40 70–0FA01 3NP40 70–0FH01 1 unit 1 unit 1.270 1.350 250 Flat connector up to 150 (M 10) 1 and 0 1 and 0 A 3NP42 70–0FA01 1 unit 2.940 400 Flat connector up to 240 (M 10) 2 and 1 2 and 1 A 3NP43 70–0FA01 1 unit 4.170 630 Flat connector up to 2 × 240 (M 12) 3 and 2 3 and 2 A 3NP44 70–0FA01 1 unit 5.490 For snapping onto busbars, 40 mm busbar center-to-center distance Busbars with a width of 12 mm or 15 mm and a thickness of 5 mm or 10 mm5) • With adapter, deep, e.g. for mounting in ALPHA meter cabinets (ALPHA 400-ZS) and ALPHA switchboards (STAB/SIKUS) 160 Flat connector Box terminal up to 2 × 70 (M 8) • Connection from top • Connection from bottom 2.5–70 or 2 × 2.5-16 • Connection from top • Connection from bottom 00 and 000 00 B B 3NP40 75–0FE01 3NP40 75–0FF01 1 unit 1 unit 1.810 1.780 00 and 000 00 B B 3NP40 75–0FK01 3NP40 75–0FJ01 1 unit 1 unit 1.820 1.830 • With adapter, flat, to DIN 43620 Part 6, for general applications and ALPHA switchboards (STAB/SIKUS) 160 Flat connector Box terminal up to 2 × 70 (M 8) • Connection from top • Connection from bottom 2.5–70 or 2 × 2.5-16 • Connection from top 00 and 000 00 and 000 00 and 000 00 and 000 • Connection from bottom 250 Flat connector up to 240 (M 10) • Connection from top or bottom 1 and 0 1 and 0 B 3NP40 75–1FE01 1 unit 1.610 B 3NP40 75–1FF01 1 unit 1.620 B 3NP40 75–1FK01 1 unit 1.710 B 3NP40 75–1FJ01 1 unit 1.630 A 3NP42 75–1CG01 1 unit 4.210 For snapping onto busbars, 60 mm busbar center-to-center distance Busbars with a width of 12 mm to 30 mm and a thickness of 5 mm or 10 mm5) flat, T and double-T profiles, and on Rittal PCS systems 160 Flat connector Box terminal 250 400 630 Flat connector Flat connector Flat connector up to 2 × 70 (M 8) • Connection from top • Connection from bottom 2.5–70 or 2 × 2.5-16 • Connection from top • Connection from bottom 00 and 000 00 B A 3NP40 76–1FE01 3NP40 76–1FF01 1 unit 1 unit 1.670 1.890 00 and 000 00 B B 3NP40 76–1FK01 3NP40 76–1FJ01 1 unit 1 unit 1.750 1.910 up to 150 (M 10) • Connection from top or 1 and 0 bottom 1 and 0 A 3NP42 76–1FG01 1 unit 4.170 up to 240 (M 10) • Connection from top or 2 and 1 bottom 2 and 1 A 3NP43 76–1FG01 1 unit 5.840 up to 2 × 240 (M 12) • Connection from top or 3 and 2 bottom 3 and 2 A 3NP44 76–1FG01 1 unit 8.230 With electronic fuse monitoring through electronic fuse monitoring for installation as a single unit 5TT3 170 (see Catalog ET B1 "BETA modular installation devices"). For all fuse switch disconnectors with flat connector connection, the appropriate cable lug covers (3NY7 101 to 3NY7 141) must be used for finger-safe cover acc. to VBG4, see Accessories. 5) For mounting on only 5 mm thick busbars, a busbar thickness compensator is required for 3NP42 and 3NP43; see Accessories. 3NP44 can only be fitted on 10 m thick busbars. 1) SIRIUS circuit-breaker, as standard with auxiliary switch 1 NO + 1 NC. On request, 3NP40 7 also with auxiliary switch 2 NO or 2 NC. 2) For 3NP40 7 with output socket for auxiliary switches, the signal cable must be ordered separately; see Accessories. For 3NP41 to 3NP44, the auxiliary switch must be connected with a 2.8 mm × 0.5 mm flat connector to DIN 46244-A. 3) Fuse links see Modular installation devices, BETA protect. 4) Insert silver-plated isolating links. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/47 6 SENTRIC NP Fuse Switch Disconnectors Accessories for power distribution ■ Selection and ordering data For fuse switch disconnectors Version DT Order No. PS* Weight per PU approx. kg Quick-fitting retaining plates between 2 standard mounting rails EN 50022 and EN 50023 3NY1 995 Center-to-center distance of mounting rails 125 mm 3NP40 10, 3NP40 70 B 3NY1 995 1 unit 0.135 Center-to-center distance of mounting rails 125 mm 3NP42 70 B 3NY7 322 1 unit 0.249 Cable lug cover and finger-safe cover in accordance with VBG 4 (1 set = 2 units) for 1 setup or 2 adapter units 3NP40 7 with flat connector1) } 3NY7 101 1 set 0.065 3NP42 7 } 3NY7 121 1 set 0.220 3NP43 3NP44 } } 3NY7 131 3NY7 141 1 set 1 set 0.221 0.319 Terminals (1 set = 3 units) Conductor cross-section 3NP42 7 70 mm2–150 mm2 B 3NY7 120 1 set 0.333 3NP43 120 mm2–240 mm2 B 3NY7 130 1 set 0.583 3NP44 150 mm2–300 mm2 B 3NY7 140 1 set 0.725 For fitting to box terminals 3NP40 1, 3NP40 7 3NY7 102 1 set 0.131 For fitting to flat connectors 3NP40 7 Conductor cross-section • solid/stranded: 2.5 mm2–16 mm2 B • finely stranded with end sleeve: B 2.5 mm2–10 mm2 3NY7 105 1 set 0.113 3NY7 102 Three-phase busbar Modular width 90 mm = 5 MW 3NP40 1 A 3NY1 237 1 unit 0.265 3NY1 263 Permissible connection 25 mm2 or feed-in terminal A busbar 1 unit 0.434 A 3NY1 438 1 unit 0.650 Triple terminal (1 set = 3 units) 3NY1 237 3NY1 238 3NY7 481 3NY3 035 for Iu max = 225 A For 2 switch disconnectors For 3 switch disconnectors For 4 switch disconnectors Connecting bar A 3NY1 263 1 unit 0.267 Cover for 1 blank space in 3NY1 238 3NP40 1 A 3NY1 265 1 unit 0.012 Feed-in terminal (1 set = 3 units) for Iu max = 225 A 3NP40 1 Conductor cross-section A • solid/stranded: 25 mm2–95 mm2 • finely stranded with end sleeve: 16 mm2–70 mm2 3NY1 236 1 set 0.262 Overreach protection 3NP42 7, 3NP43, 3NP44 B 3NY7 481 1 unit 0.021 Sealing pin (1 package = 10 units) 3NP42 7, 3NP43, 3NP44 B 3NY7 482 Busbar thickness compensator (1 kit = 5 units) for only 5 mm thick busbar 3NP42 7, 3NP43 B 3NY7 381 1 set 0.064 Fuse carrier gray with inscription plate with voltage testing holes 3NP40 1 3NP40 7 B B 3NY7 003 3NY7 001 1 unit 1 unit 0.160 0.220 Auxiliary switch 1 CO for sizes 000 and 00 with self-tapping screws for sizes 1 to 3 for plugging on 3NP40 1 to 3NP44 } 3NY3 035 1 unit 0.004 3NY1 236 NSE00172 6 Electronics-compatible Fuse links size 000 with non-insulated grip lugs, operational class gL/gG for cable and line protection, width 21 mm to IEC 60269-2-1 and DIN 43620 Signal cable for connection to size 00 fuse monitor output socket 1 m cable with plug 3 m cable with plug 3NP40 1 3NP40 7 3NP40 7 400 V/125 A 400 V/160 A 10 units 0.056 B 3NY3 030 1 unit 0.004 B B 3NY1 822 3NY1 824 1 unit 1 unit 0.130 0.129 B B 3NY1 910 3NY1 911 1 unit 1 unit 0.097 0.261 1) The fuse switch disconnector can be used without difficulty with mounted cable lug cover in conjunction with molded-plastic masking frames for distribution board/equipment panel or incoming-feeder panel in the meter cabinet. 6/48 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC NP Fuse Switch Disconnectors Accessories for power distribution Masking frames For fuse switch disconnectors Height × Width DT Order No. PS* Weight per PU approx. kg mm For installation in any distribution board1) Molded-plastic masking frame 3NY1 251 3NP40 1 3NP40 7 with box terminals 3NP40 7 with flat connector 215 × 130 215 × 130 215 × 130 A } } 3NY1 251 3NY7 200 3NY7 201 1 unit 1 unit 1 unit 0.052 0.037 0.046 3NP42 7 3NP43 3NP44 375 × 220 375 × 245 375 × 290 } B B 3NY7 220 3NY7 230 3NY7 240 1 unit 1 unit 1 unit 0.112 0.117 0.125 For installation in ALPHA 400-ZS meter cabinets See publication "Installation and Mounting", Order No. E20001–P285–A526–V1 (in German only). Molded-plastic masking frame 2 × 3NP40 1 197 × 215.5 A 3NY1 258 1 unit 0.063 for distribution panels 1 × 3NP40 1 left 1 × 3NP40 1 right 1 × 3NP40 7 left 1 × 3NP40 7 right 2 × 3NP40 7 197 × 215.5 197 × 215.5 208 × 229 208 × 229 208 × 229 A A B B B 3NY1 262 3NY1 264 3NY7 500 3NY7 501 3NY7 502 1 unit 1 unit 1 unit 1 unit 1 unit 0.093 0.091 0.120 0.120 0.054 3NP42 7 3NP43 3NP44 309 × 216 375 × 245 375 × 290 } B B 3NY7 220 3NY7 230 3NY7 240 1 unit 1 unit 1 unit 0.112 0.117 0.125 or suitable for the feed-in area of a meter cabinet (mounting onto busbars) For installation in ALPHA 160 and ALPHA 400 wall-mounted distribution boards (STAB 160/STAB 400) and ALPHA 630 floor-mounted distribution boards (SIKUS 630) for mounting on support plate or busbars 1 × 3NP40 1 right 1 × 3NP40 1 left 2 × 3NP40 1 166 × 199 166 × 199 166 × 199 A A A 3NY1 260 3NY1 261 3NY1 248 1 unit 1 unit 1 unit 0.082 0.086 0.036 For further information see Catalog ET A1 "ALPHA distribution boards" 1 × 3NP40 7 left 1 × 3NP40 7 right 2 × 3NP40 7 208 × 229 208 × 229 208 × 236 B B B 3NY7 500 3NY7 501 3NY7 502 1 unit 1 unit 1 unit 0.120 0.120 0.054 3NP42 7 3NP43 3NP44 309 × 2162) 375 × 245 375 × 290 B B B 3NY7 820 3NY7 230 3NY7 240 1 unit 1 unit 1 unit 0.113 0.117 0.125 Molded-plastic masking frame For installation in STAB/SIKUS Universal 8GF Masking frames and installation kits are available for all switch disconnectors fuse links belonging to sizes 000 to 3. Order Nos. and prices on request. For fuse switch disconnectors 8HP enclosure DT Order No. PS* Weight per PU approx. kg Size For installation in SENTRIC 8HP molded-plastic distribution system Molded-plastic masking frame 1 × 3NP40 10 1 × 3NP40 70 1 1 B B 8HP6 431 8HP6 422 1 unit 1 unit 0.221 0.224 2 × 3NP40 10 3 × 3NP40 10 1 × 3NP40 70 2 × 3NP40 70 2 2 2 2 B B B B 8HP6 432 8HP6 432 8HP6 423 8HP6 424 1 unit 1 unit 1 unit 1 unit 0.465 0.465 0.230 0.203 1 × 3NP40 70 2 × 3NP40 70 1 × 3NP42 70 2.5 2.5 2.5 B B B 8HP6 423 8HP6 424 8HP6 427 1 unit 1 unit 1 unit 0.230 0.203 0.250 NSE00173a for installation in 8HP complete enclosure with fuse switch disconnectors See also Catalog "8HP insulated distribution system", Order No. 8ZX1012-0HP54-5AB1 (in German only). 1) To some extent, special masking frames are required for installation in ALPHA wall-mounted, floor-mounted and meter distribution boards (STAB, SIKUS, SIPRO); see Accessories. 2) With the 8GE3 818-0 support plate it is also possible to use the 3NY7 220 molded-plastic masking frame (for installation in any distribution board). * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/49 6 SENTRIC NP Fuse Switch Disconnectors Accessories for power distribution Masking frames For fuse switch disconnectors Height × Width DT Order No. PS* mm Weight per PU approx. kg For installation in 8GD/8GA "classic" STAB/SIKUS switchboards See publication "Installation and Mounting", Order No. E20001-P285-A526-V1 (in German only). Molded-plastic masking frame for fitting between two standard mounting rails with 3NY1 995 quick-fitting retaining plate 1 × 3NP40 10 right with and without auxiliary switches 197 × 215.5 A 3NY1 256 1 unit 0.116 1 × 3NP40 10 left with and without auxiliary switches 197 × 215.5 A 3NY1 257 1 unit 0.118 in a cut-out of B1 width 2 × 3NP40 10 with and without auxiliary switches 197 × 215.5 A 3NY1 258 1 unit 0.063 in a cut-out of B2/2 width 2 × 3NP40 10 with and without auxiliary switches 197 × 235 A 3NY1 250 1 unit 0.075 in a cut-out of B2 width 3 × 3NP40 10 with and without auxiliary switches (support included in scope of supply) 197 × 485 B 3NY1 253 1 unit 0.225 4 × 3NP40 10 with and without auxiliary switches (support included in scope of supply) 197 × 485 B 3NY1 254 1 unit 0.188 5 × 3NP40 10 with and without auxiliary switches 197 × 485 A 3NY1 255 1 unit 0.125 C 3NY1 271 1 set 0.100 3NY1 250 3NY1 253 6 3NY1 255 3NY1 260 3NY1 247 Support 3NP40 1 (1 set = 10 units) for 3NY1 253 and 3NY1 254 moldedplastic masking frame Molded-plastic masking frame for snapping of 3NP40 1 switch disconnectors onto standard mounting rail with special 8GD9 support and for mounting onto busbars (except 3NY1 247) 1 × 3NP40 1 right with and without auxiliary switches 166 × 199 A 3NY1 260 1 unit 0.082 1 × 3NP40 1 left with and without auxiliary switches 166 × 199 A 3NY1 261 1 unit 0.086 in a cut-out of B1 width 2 × 3NP40 1 with and without auxiliary switches 166 × 199 A 3NY1 248 1 unit 0.036 in a cut-out of B2 width 5 × 3NP40 1 with and without auxiliary switches 166 × 469 A 3NY1 247 1 unit 0.072 Blanking cover (1 set = 10 units) for covering a blank cut-out in the 3NY1 2 masking frame 3NP40 1 Width 90 B 3NY1 270 1 set 0.040 Molded-plastic masking frame for fitting between two standard mounting rails with 3NY1 995 quick-fitting retaining plate 1 × 3NP40 7 left 1 × 3NP40 7 right 208 × 219 208 × 219 B B 3NY7 800 3NY7 801 1 unit 1 unit 0.100 0.120 2 × 3NP40 7 208 × 222 B 3NY7 802 1 unit 0.060 with 3NY1 322 quick-fitting retaining plate 1 × 3NP42 7 309 × 216 B 3NY7 820 1 unit 0.113 Molded-plastic masking frame for fitting on 8GD9 100 support plate 1 × 3NP40 7 left 208 × 229 B 3NY7 500 1 unit 0.120 1 × 3NP40 7 right 208 × 229 B 3NY7 501 1 unit 0.120 2 × 3NP40 7 208 × 236 B 3NY7 502 1 unit 0.054 1 × 3NP42 70 309 × 2161) B 3NY7 820 1 unit 0.113 onto 8GD9 591 support plate 1 × 3NP43 70 375 × 245 B 3NY7 230 1 unit 0.117 onto 8GD9 592 support plate 1 × 3NP44 70 375 × 290 B 3NY7 240 1 unit 0.125 Molded-plastic masking frame for fixing 1) When mounting on 8GD9 590 support plate it is also possible to use the 3NY7 220 molded-plastic masking frame. 6/50 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC NP Fuse Switch Disconnectors For high technical requirements ■ Selection and ordering data Fully compartmented, with high-speed closing Rated uninterrupted current Iu Conductor connections (on both sides) Connection For conductor cross-section mm2 A For fuse links For Auxiliary DT to isolating switches DIN 436201) links of the switch disconnector Degree of protecPS* tion IP00, without fuse links, without isolating links, with terminal screws Weight per PU approx. Size kg Size Version Order No. For surface mounting and for installation 160 250 400 630 Flat connector6) 2.5–1502) 00 and 000 00 without3) } 1 NO + 1 NC B 3NP50 60–0CA00 3NP50 60–0CA10 1 unit 1 unit 1.600 1.650 Terminal clamp 1 conductor 2.5–50 or 2 conductors 1× 2.5–50 1× 2.5–35 00 and 000 00 without3) A 1 NO + 1 NC B 3NP50 60–0CB00 3NP50 60–0CB10 1 unit 1 unit 1.730 1.740 Flat connector 6–1504) 1 and 0 1 none } 1 NO + 1 NC A 3NP52 60–0CA00 3NP52 60–0CA10 1 unit 1 unit 5.470 5.490 Terminal clamp 35–120 1 and 0 1 none C 1 NO + 1 NC B 3NP52 60–0CB00 3NP52 60–0CB10 1 unit 1 unit 5.600 5.810 Flat connector 6–2404) 2 and 1 2 none } 1 NO + 1 NC A 3NP53 60–0CA00 3NP53 60–0CA10 1 unit 1 unit 6.530 6.550 none } 1 NO + 1 NC B 3NP54 60–0CA00 3NP54 60–0CA10 1 unit 1 unit 7.940 7.950 Flat connector 6–2 × 2404) 3 and 2 3 For adaptation to busbar systems5), 40 mm busbar center-to-center distance Busbars of 12 mm in width and 5 mm or 10 mm in thickness 160 Flat connector 2.5–1502) Connection from bottom 00 and 000 none C 1 NO + 1 NC B 3NP50 65–1CF00 3NP50 65–1CF10 1 unit 1 unit 2.380 2.370 Terminal clamp 1 conductor 2.5–50 or 2 conductors 1× 2.5–50 1× 2.5–35 Connection from bottom 00 and 000 none B 1 NO + 1 NC B 3NP50 65–1CG00 3NP50 65–1CG10 1 unit 1 unit 2.430 2.430 For adaptation to busbar systems5), 60 mm busbar center-to-center distance Use switch version "for surface mounting and flush mounting" and busbar adapters, see Accessories. 1) Fuse links see BETA protect modular installation devices. 2) Acc. to DIN 46234 or 16 mm2–95 mm2 acc. to DIN 46235 (use M 10 cable lug if necessary). 3) Additional holes on the switch are necessary if the auxiliary switch is retrofitted. 4) Acc. to DIN 46234 or DIN 46235; with cable lug to DIN 46235: min. conductor cross-section 16 mm2 (use M 12 cable lug if necessary). 5) Accessories and further devices for busbar systems, see Accessories and distribution and busbar systems and switchgear. 6) For 3NP50 60 with flat connectors, appropriate 3NY1 106 cable lug covers must be used to provide finger-safe cover to DIN VDE 0106 Part 100 (see Accessories). * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/51 6 SENTRIC NP Fuse Switch Disconnectors For high technical requirements Fully compartmented, with high-speed closing with fuse monitoring by SIRIUS circuit-breaker1) Rated Conductor connections (on both uninter- sides) rupted Connection For conductor current cross-section Iu mm2 A For fuse links to DIN 436202) Auxiliary switches of the switch disconnector Auxiliary switches of the circuitbreaker Size Version Version DT Degree of protec- PS* tion IP00, without fuse links, without isolating links, with terminal screws Weight per PU approx. Order No. kg For surface mounting and for installation With plug connection for connecting leads from auxiliary contacts (approx. 1 m long) to the circuit-breaker Flat connector6) 2.5–1503) 00 and 000 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 2 NO } 3NP50 60–0EA86 B 3NP50 60–0EA26 1 unit 1 unit 2.480 2.550 Terminal clamp 1 conductor 2.5–50 2 conductors 1× 2.5–50 1× 2.5–35 00 and 000 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 2 NO B 3NP50 60–0EB86 B 3NP50 60–0EB26 1 unit 1 unit 2.610 2.650 Flat connector 6–1504) 1 and 0 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 2 NO } 3NP52 60–0EA86 B 3NP52 60–0EA26 1 unit 1 unit 6.010 6.860 Terminal clamp 35–120 1 and 0 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 2 NO B 3NP52 60–0EB86 B 3NP52 60–0EB26 1 unit 1 unit 7.090 6.650 400 Flat connector 6–2404) 2 and 1 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 2 NO } 3NP53 60–0EA86 B 3NP53 60–0EA26 1 unit 1 unit 7.080 5.410 630 Flat connector 6–2 × 2404) 3 and 2 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 2 NO } 3NP54 60–0EA86 B 3NP54 60–0EA26 1 unit 1 unit 8.460 9.230 160 250 6 For adaptation to busbar systems5), 40 mm busbar center-to-center distance Busbars of 12 mm wide and 5 mm or 10 mm thick 160 Flat connector 2.5–1503) 00 and 000 Connection from bottom 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 2 NO A 3NP50 65–1EF86 B 3NP50 65–1EF26 1 unit 1 unit 2.900 2.950 Terminal clamp 1 conductor 00 and 000 2.5–50 2 conductors 1× 2.5–50 1× 2.5–35 Connection from bottom 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 2 NO B 3NP50 65–1EG86 C 3NP50 65–1EG26 1 unit 1 unit 3.020 2.970 For adaptation to busbar systems5), 60 mm busbar center-to-center distance Use disconnector versions "for surface mounting and flush mounting" and busbar adapters, see Accessories. 1) SIRIUS circuit-breaker on request also auxiliary switch 2 NC. 2) Fuse links see Modular installation devices, BETA protect. 3) Acc. to DIN 46234 or 16 mm2–95 mm2 acc. to DIN 46235 (use M 10 cable lug if necessary). 4) Acc. to DIN 46234 or DIN 46235; with cable lug to DIN 46235: Min. conductor cross-section 16 mm2 (use M 12 cable lug if necessary). 5) Accessories and further devices for busbar systems, see Accessories and distribution and busbar systems and switchgear. 6) For 3NP50 60 with flat connectors, appropriate 3NY1 106 cable lug covers must be used to provide finger-safe cover, acc. to DIN VDE 0106 Part 100 (see Accessories). 6/52 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC NP Fuse Switch Disconnectors For high technical requirements Fully compartmented, with high-speed closing with electronic fuse monitoring EFM (internal power supply) version "A" (open-circuit principle)1) for rated operating voltages Ue from AC 400 V to 500 V Feed-in must be from above! Rated Conductor connections For uninter- (on both sides) fuse links to 2 rupted Connection For conduc- DIN 43620 ) current tor cross-secIu tion mm2 A Size Auxiliary switches of the switch disconnector Auxiliary switches of the fuse monitoring device Version Version DT Degree of protecPS* tion IP00, without fuse links, without isolating links, with terminal screws Weight per PU approx. Order No. kg For surface and flush mounting With plug connection for connecting leads from auxiliary contacts (approx. 1 m long) to the fuse monitoring device Operating display: green LED lighting, fault display: green LED flashing Fuse failure display: red LED (individual display per phase) 160 250 Flat connector5) 2.5–1203) 00 and 000 1 NO + 1 NC 2 NO + 1 NC B 3NP50 60–0HA13 1 unit 2.370 Terminal clamp 1 conductor 2.5–50 2 conductor 1× 2.5–50 1× 2.5–35 00 and 000 1 NO + 1 NC 2 NO + 1 NC B 3NP50 60–0HB13 1 unit 2.500 1 and 0 1 NO + 1 NC 2 NO + 1 NC B 3NP52 60–0HA13 1 unit 5.860 Flat connector 6–1504) 6 400 Flat connector 6–2404) 2 and 1 1 NO + 1 NC 2 NO + 1 NC B 3NP53 60–0HA13 1 unit 6.950 630 Flat connector 6–2404) 3 and 2 1 NO + 1 NC 2 NO + 1 NC B 3NP54 60–0HA13 1 unit 8.510 1) Please inquire about version "R" (closed-circuit principle). (See also equivalent circuit diagram.) 2) Fuse links see Modular installation devices, BETA protect. 3) Acc. to DIN 46234 or 16 mm2–95 mm2 acc. to DIN 46235 (use M 10 cable lug if necessary). 4) Acc. to DIN 46234 or DIN 46235; with cable lug to DIN 46235: Min. conductor cross-section 16 mm2 (use M 12 cable lug if necessary). 5) For 3NP50 60 with flat connectors, appropriate 3NY1 106 cable lug covers must be used to provide finger-safe cover, acc. to DIN VDE 0106 Part 100 (see Accessories). * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/53 SENTRIC NP Fuse Switch Disconnectors For high technical requirements Fully compartmented, with high-speed closing with electronic fuse monitoring EFM (internal power supply) version "A" (open-circuit principle)1) for rated operating voltages Ue from 400 V to 500 V Feed-in must be from above! Rated Conductor connections For uninter- (on both sides) fuse links to 2 rupted Connection For conduc- DIN 43620 ) current tor cross-secIu tion A mm2 Size Auxiliary switches of the switch disconnector Auxiliary switches of the fuse monitoring device Version Version DT Degree of protecPS* tion IP00, without fuse links, without isolating links, with terminal screws Weight per PU approx. Order No. kg For adaptation to busbar systems4), 40 mm busbar center-to-center distance Busbars of 12 mm wide and 5 mm or 10 mm thick 160 Flat connector 2.5–1203) Connection from bottom 00 and 000 1 NO + 1 NC 2 NO + 1 NC B 3NP50 65–1HF13 1 unit 2.770 For adaptation to busbar systems4), 60 mm busbar center-to-center distance Use disconnector versions "for surface mounting and installation" and busbar adapters, see Accessories. 6 1) Please inquire about version "R" (closed-circuit principle). (See also equivalent circuit diagram.) 2) Fuse links see Modular installation devices, BETA protect. 3) Acc. to DIN 46234 or 16 mm2–95 mm2 acc. to DIN 46235 (use M 10 cable lug if necessary). 4) Accessories and further devices for busbar systems, see Accessories and components for distribution systems. 6/54 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC NP Fuse Switch Disconnectors Accessories for high technical requirements ■ Selection and ordering data For fuse switch disconnectors Height × Width DT Order No. PS* mm Weight per PU approx. kg For installation in any distribution board 3NY1 107 3NY1 106 Molded-plastic masking frame for installation in the cabinet 3NP50 with and without auxiliary switch with auxiliary switch Molded-plastic masking frame for installation in metal front plate with and without auxiliary switch Molded-plastic masking frame for covering the connection terminals 3NP50 with and without auxiliary switch Molded-plastic masking frame for covering the cable lug connections 3NP50 with and without auxiliary switch Molded-plastic masking frame for separate covering of the upper and lower cable lug connections with auxiliary switch 3NP50 with and without auxiliary switch Installation kit for flush mounting with molded-plastic masking frame, fixing brackets and sundries 3NY1 212 3TX6 546–3B A 3NY1 105 1 unit 0.045 215 × 135 A 3NY1 115 1 unit 0.044 220 × 160 B 3NY1 125 1 unit 0.062 265 × 135 A 3NY1 107 1 unit 0.073 290 × 135 A 3NY1 106 1 unit 0.071 290 × 135 A 3NY1 116 1 unit 0.071 290 × 135 A 3NY1 108 1 unit 0.048 215 × 135 3NP50 60 250 × 149 B 3NY1 208 1 unit 0.531 3NP52 60 300 × 220 B 3NY1 210 1 unit 0.287 3NP53 60 300 × 245 B 3NY1 211 1 unit 0.298 3NP54 60 300 × 290 B 3NY1 212 1 unit 0.313 For disconnectors with and without auxiliary switches Cover for cable lug connection (1 set = 6 units) can be screwed onto free screw end to protect against accidental touch 3NP52 Cover length 99 mm A 3NY1 241 1 set 0.205 3NP53/3NP54 60 Cover length 95 mm Cover length 120 mm B B 3TX6 546–3B 3NY1 245 1 set 1 set 0.249 0.336 For installation in any distribution board Conductor cross-section Terminal clamp (1 set = 3 units) 3NP50 2.5–50 mm21) B 3NY1 903 1 set 0.108 3NP52 35–120 mm2 B 3NY1 907 1 set 0.225 3NP50 108 mm wide A 8US12 91–4SB00 1 unit 0.551 3NP52, 3NP53, 3NP542) 250 mm wide A (320 mm long, terminal screws M 10, connecting leads must be manufactured to the disconnector) 8US12 10–4AG00 1 unit 3.060 3NY1 940 1 set 0.010 3NY1 907 Busbar adapter for 60 mm busbar system 8US12 10–4AG00 Sealing lug retrofittable (1 package = 10 units) 3NP50 B 1) Optionally also 2 conductors: 1 × 2.5 mm2 to 50 mm2 and 1 × 2.5 mm2 to 35 mm2. 2) Disconnector is wider than adapter. The adapter can, however, be expanded to 276 mm with 2 8US19 98–2BM00 side modules. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/55 6 SENTRIC NP Fuse Switch Disconnectors Accessories for high technical requirements For fuse switch disconnectors DT Order No. PS* Weight per PU approx. Fuse carrier 3NP50 6 .–.C. .0 3NP52 60–.C. .0 3NP53 60–.C. .0 3NP54 60–.C. .0 B B B B 3NY1 074 3NY1 371 3NY1 372 3NY1 373 1 unit 1 unit 1 unit 1 unit 0.620 0.263 1.510 1.690 With fuse monitoring by 3RV1 circuit-breaker (with auxiliary switch 1 NO + 1 NC), with plug-in connection, without plug and connecting lead 3NP50 6 .–.E. .6 3NP52 60–.E. .6 3NP53 60–.E. .6 3NP54 60–.E. .6 B B B B 3NY1 420 3NY1 421 3NY1 422 3NY1 423 1 unit 1 unit 1 unit 1 unit 1.400 1.900 1.980 2.600 3NP5 with 3RV1 B B 3NY1 910 3NY1 911 1 unit 1 unit 0.097 0.261 With electronic fuse monitoring for 400 V-500 V (with auxiliary switch 2 NO + 1 NC), with plug-in connection, without plug and connection lead) 3NP50 6 .–.H .13 3NP52 60–.H .13 3NP53 60–.H .13 3NP54 60–.H .13 B C B C 3NY1 513–0 3NY1 513–2 3NY1 513–3 3NY1 513–4 1 unit 1 unit 1 unit 1 unit 1.230 2.130 2.140 0.325 Plug and connecting lead (6-pole) 3 m long 3NP5 with EFM B 3NY1 915 1 unit 0.372 Strain relief assembly kit for control cable of the EFM 3NP5 with EFM D 3NY1 918 1 set 0.024 With actuating cams, screws and washers (mounting kit) 3NP501) B 3NY3 033 1 unit 0.015 With fixing bracket and screws (installation kit) 3NP52–3NP54 B 3NY3 034 1 unit 0.015 Arc chute (3 units each are required for 3NP52, 3NP53 and 3NP54) 3NP50 B 3NY4 031 1 unit 0.218 3NP52 B 3NY4 011 1 unit 0.215 3NP53, 3NP54 B 3NY4 012 1 unit 0.240 3NY1 210 3NY1 211 3NY1 212 A A A 3NY1 102 3NY1 103 3NY1 104 1 unit 1 unit 1 unit 0.071 0.075 0.084 kg 3NY1 074 Plug and connection lead 1 m long 3 m long 3NY1 513–3 6 3NY1 915 Auxiliary switch 1 NO + 1 NC 3NY3 033 3NY3 034 3NY4 031 3NY4 011 Molded-plastic masking 300 × 220 mm frame as replacement for 300 × 245 mm masking frames from installa- 300 × 290 mm tion kits for flush mounting (without fixing bracket and sundries) 1) When retrofitted, holes must be drilled. 6/56 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC NP Fuse Switch Disconnectors Project planning aids ■ Dimension drawings 2,5 M5 NSE00192 5,8 97,5 43,5 125 NSE00191 50 70 155 168,5 M5 70 17,5 NSE00193 7,5 85 50 100 25,5 25,5 3NY1 995 quick-fitting retaining plate for 3NP40 10 and 3NP40 70 M5 50 28,5 85 13,8 NSE 00190a 68 27 127,5 Top holes with a 50 mm intermediate dimension must be used for installation in STAB 8GD wallmounting distribution boards. 174 3NY1 265 covering cap for 3NY1 238 threephase busbar 21 21 21 3,5 28,5 NSE 00197a 62,5 28 3,5 3NP40 15–1CJ01 with busbar adapter, flat, for busbars 12 mm or 15 mm wide and 5 mm or 10 mm thick, connection from bottom 19 100,5 7,5 18 30 215 41,5 144,5 40 40 58,5 89 NSE 00201a 130 18 16,5 3NP40 10 with 3NY1 251 molded-plastic masking frame 28 NSE 00196a 16 13 NSE00195 12 NSE 00194a 21 72 5 10,5 3NP40 10 with 3NY1 236 feed-in terminal 18 35 63 28,5 14 3NP40 10 with 3NY1 235 triple terminal 20 35 3NP40 10 with 3NY1 237 three-phase busbar for 2 fuse switch disconnectors 62,5 Auxiliary switch 9,5 50 73,5 44 48 143 126,5 52 5,8 64,5 44,5 89 3NP40 10 with 3NY1 995 quick-fitting retaining plate Standard mounting rails with 125 mm center-to-center distance 97,5 43,5 34,5 Mounting cutout for 3NP35 and 3NP40 10 3NP40 10 89 19 121,5 7,5 100,5 69,5 72 60 25,5 25,5 201 100,5 69,5 60 168 11,5 60 14 19 89 168 11,5 25,5 25,5 222 3NP40 16–1CK01 with busbar adapter, for busbars 12, 15, 20, 25 mm or 30 mm wide and 5 mm or 10 mm thick, flat, T-shaped, double-T-shaped and other well-known busbar systems, connection from top NSE 00204a 19 60 89 10,5 3NP40 16–1CJ01 with busbar adapter, for busbars 12, 15, 20 mm or 30 mm wide and 5 mm or 10 mm thick, flat, T-shaped, double-T-shaped and other well-known busbar systems, connection from below 93 25,5 25,5 NSE 00205a 201 14 72 25,5 25,5 10 7,5 18 18 144,5 40 40 NSE 00907a 100,5 201 3NP40 15–0CJ01 with busbar adapter, deep, for busbars 12 mm or 15 mm wide and 5 mm or 10 mm thick, connection from bottom NSE 00202a 16,5 19 144,5 40 40 89 72 25,5 25,5 174 3NP40 15–1CK01 with busbar adapter, flat, for busbars 12 mm or 15 mm wide and 5 mm or 10 mm thick, connection from top 16,5 NSE 00200a 72 201 Siemens LV 30 · 2004 6/57 6 SENTRIC NP Fuse Switch Disconnectors Project planning aids 3NP40 70 for surface mounting 3NP42 70, 3NP43 70, 3NP44 70 for surface mounting a 8 3 ,5 4 5 c d 3 6 ,5 N S E 0 _ 0 0 2 0 7 a 1 0 8 1 7 0 5 0 b 7 0 e f N S E 0 _ 0 0 2 0 6 b 1 7 8 3 ,5 1 0 1 f 1 9 0 Drilling pattern for 3NP40 70 a B c d e f 184 210 256 243 288 300 66 80 94.5 45.5 48 48 215 255 267 57 65 81 Quick-fitting retaining plate 3NY73 22 M6 84 50 2 65 For plastic frames 2) 16 11 25 50 NSE00213 17 NSE00523 5,8 157 110 195 70 50 217 81 81 Mounting cutouts2) for 3NP42 for 3NP40 70 161 130 40 40 170 65 $ Lower edge, disconnector base frame % Center, disconnector base frame 111 72 50 50 NSE00209 16 238 84 70 11 NSE00212 2 17 93 19 108 50 Drilling pattern for 3NP44 11 NSE00211 85 116 130 116 114 130 118 For metal frames Mounting cutouts for 3NP4 cutouts 2) h1) 180 195 100 110 220 245 290 375 375 375 210 235 280 275 315 325 157 174 178 Molded-plastic masking frame in front of control panel 3NP40 1 3NP40 7 3NP42 7 3NP43 7 3NP44 7 Type B H B H h1) 3NY1 251 3NY7 200, 3NY7 201 3NY7 220 3NY7 230 3NY7 240 130 130 215 215 100 118 155 195 87 110 220 245 290 375 375 375 198 224 270 275 315 325 157 174 178 1) h = distance from top edge of panel cutout to center of disconnector mounting. 6/58 Siemens LV 30 · 2004 11 267 H 100 118 11 162 130 NSE00526 B 215 215 174 H 130 130 50 3NP42 7 3NP43 7 3NP44 7 B 315 B Type 3NY1 251 3NY7 200, 3NY7 201 3NY7 220 3NY7 230 3NY7 240 Mounting cutouts 2) for 3NP44 Mounting for 3NP43 NSE00525 H Molded-plastic masking frame behind control panel 3NP40 1 3NP40 7 198 Panel cutout min. 50 Masking frame between assembly kit h Type 177,5 170 Drilling pattern for 3NP43 3NP40 75–1 with busbar adapter, flat, for busbars 12 mm or 15 mm wide and 5 mm or 10 mm thick NSE 00906a 6 70 161 130 40 40 122,5 50 2 274,4 85 132 19 NSE00210 108 114 6,5 NSE0052 11 3NP40 75–0 with busbar adapter, deep, for busbars 12 mm or 15 mm wide and 5 mm or 10 mm thick Drilling pattern for 3NP42 70 NSE00524 1 Type 3NP42 70 3NP43 70 3NP44 70 81,7 97,5 5,8 70 83,5 NSE00208 50 270 224 2) Masking frame rests open on control panel front; for masking frame behind control panel front: cutout dimensions on request. Project planning aids 3NP40 70–0F for surface mounting and flush mounting 1 1 4 ,5 5 7 19 210 64 16 241,5 3NP40 75–1F with busbar adapter, flat, 40 mm, busbars 12 mm or 15 mm wide and 5 mm or 10 mm thick 3NP40 76–0F with busbar adapter, flat, 60 mm, busbars 12 mm or 30 mm wide and 5 mm or 10 mm thick 19 189 60 189 220,5 NSE 00904a 220,5 NSE 00903a 64 16 60 179 160,7 40 40 19 NSE 00902a 1 9 3 ,5 64 16 8 3 ,5 N S E 0 _ 0 0 9 0 1 c 6 4 1 6 1 5 8 ,5 160,7 40 40 11,6 3 6 ,5 3NP40 75–0F with busbar adapter, deep, 40 mm, busbars 12 mm or 15 mm wide and 5 mm or 10 mm thick Siemens LV 30 · 2004 6/59 Project planning aids 19 a d 111 f 186 168 a b1) c d e f 3NP42 75-1 3NP42 76-1 3NP43 76-1 3NP44 76-1 184 184 210 256 243 243 288 300 832) 832) 97 112 45.5 45.5 48 48 111 111 125 139 40 60 60 60 3NY7 220 molded-plastic masking frame for 3NP42 for installation in any distribution board 40 NSE00527 375 215 215 NSE00216 130 c Type 3NY7 201 molded-plastic masking frame for 3NP40 7.for 3NP40 7.-CA01 40 3NY7 200 molded-plastic masking frame for 3NP40 7 for installation in any distribution board 217 e 89 72 NSE00214 16 9 17 84 70 60 170 50 b 60 f 108 with busbar adapter, for busbars 12 mm to 30 mm wide and 5 mm or 10 mm thick, flat, T-shaped and double-T-shaped 3NP42 75–1 3NP42 76–1 3NP43 76–1 3NP44 76–1 NSE00215 10,5 3NP40 76–1 with busbar adapter, for busbars 12 mm to 30 mm wide and 5 mm or 10 mm thick, flat, T-shaped and double-T-shaped 130 220 3NY7 820 molded-plastic masking frame for one 3NP42 70 switch disconnector for installation in STAB/SIKUS switchboards 375 375 271 309 67,5 49 3NY7 240 molded-plastic masking frame for 3NP44 for installation in any distribution board 70,5 3NY7 230 molded-plastic masking frame for 3NP43 for installation in any distribution board NSE00217 NSE00220 216 245 NSE00218 290 1) For VBG4 plus dimension c of the cable lug covers (see Page 6/61). 2) The 3NY7 820 molded-plastic masking frame is used for depth compensation (below) when installed together with size 000 or size 00 in STAB/SIKUS switchboards. 6/60 Siemens LV 30 · 2004 NSE00219 Project planning aids 3NY7 501 molded-plastic masking frame for one 3NP40 switch disconnector, right for installation in SIKUS 3200, STAB 160 and 400 and SIKUS 630 switchboards N S E 0 _ 0 0 2 2 3 b 64 6 4 6 4 1 0 8 2 3 6 47 47 2 0 8 208 NSE00222 6° 6° 229 229 94 108 Cable lug cover for 3NP42 to 3NP44, 3NY7 121, 3NY7 131, 3NY7 141 a b c 3NY7 121 3NY7 131 3NY7 141 181 207 253 65 79 94 67 50 47 b Type NSE00225 a c 35 30 61 Cable lug cover for 3NP40 7 with flat connector, 3NY7 101 NSE00224 4 6 46 208 NSE00221 64 3NY7 502 molded-plastic masking frame for two 3NP40 switch disconnectors, for installation in SIKUS 3200, STAB 160 and 400 and SIKUS 630 switchboards 46 3NY7 500 molded-plastic masking frame for one 3NP40 switch disconnector, left for installation in SIKUS 3200, STAB 160 and 400 and SIKUS 630 switchboards Siemens LV 30 · 2004 6/61 Project planning aids b 165 173 12 c a c 30° b 3NY1 105 135 215 3NY1 115 135 215 95.5 38 3NY1 106 135 290 144.5 64 3NY1 108 135 290 144.5 64 3NY1 208 149 250 115 135 d 30 95.5 38 53.5 For plastic frames Mounting cutout for 3NP50 60, with and without auxiliary contact Mounting cutout for 3NY1 208 installation kit NSE00229 70 5,8 300 2 a 191 207,5 196 161,5 NSE00228a 3NP50 60, 160 A with fuse monitoring by 3RV1 circuit-breaker, with plug connector 45 Type NSE00230 228 205 19 91 22 36 36 134 Auxiliary switch 34 M8 30 30° 97 84 63 196 63 70 Ø5,8 NSE00227 NSE00231 230 NSE00226 97,5 3NY1 107 molded-plastic masking frame 36 15 31 116 3NP50 60, 160 A with molded-plastic masking frame for any installation d 3NP50 60, 160 A for surface mounting 130 126,5 143 6 134 For metal frames Mounting cutouts for 3NP5 228 NSE 00906a H h Type B Masking frame between assembly kit Panel cutout min. Molded-plastic masking frame behind control panel B H B H h1) 135 215 130 206 115 3NP52 6 3NY1 210 222 300 210 293 146 3NP53 6 3NY1 211 245 300 235 293 146 3NP54 6 3NY1 212 290 300 280 293 146 Type 3NP50 6 3NY1 105 2) 3NP50 6 3NY1 125 Molded-plastic masking frame in front of control panel B H B H h1) 3NP50 6 3NY1 105 135 215 130 205 115 3NP50 6 3NY1 208 149 250 143 191 – 3NP52 6 3NY1 210 220 300 210 262 132 3NP53 6 3NY1 211 245 300 234 262 132 3NP54 6 3NY1 212 290 300 279 262 132 Type 1) h = distance from top edge of switch panel cutout to center of disconnector mounting. 2) With standard molded-plastic masking frame behind the control panel and corresponding control panel cutout, the specified switching capacity is reduced to the following AC 23B values: at 400 V Ie 160 V, at 500 V from Ie 160 V to 125 A and at 690 V from Ie 100 A to 50 A. 6/62 Siemens LV 30 · 2004 Project planning aids 76 f 7 6 1 0 u w 2 8 0 3 0 0 251 c s t d l e i h N S E 0 _ 0 0 2 3 3 b r 8 m 3NP5. 60, 250 to 630 A with fuse monitoring by 3RV circuit-breaker, with plug connector q N S E 0 _ 0 0 2 3 5 b 9 4 Type a B c d e f g h I 3NP52 60 3NP53 60 3NP54 60 207 231 276 202 226 271 130 130 200 93 106 111 62 70 85 176 192 207 38 39 40.5 41 39 40.5 11.5 11.5 11.5 k1) l1) m 3NP52 60 3NP53 60 3NP54 60 3NP52 60 3NP53 60 3NP54 60 3 3 2 9 Mounting cutout for 3NP52 60, 3NP53 60 and 3NP54 60 M 8 o k e 28 n 262 280 r 10 4 f d 12 9 20 60 g NSE00232 a b 3NP5. 60, 250 to 630 A with molded-plastic masking frame, for flush mounting NSE00234 3NP5. 60, 250 to 630 A for surface mounting N o q r s t M 10 M 8 336 M 10 M 10 352 M 10 M 10 367 25 25 30 32 25 25 212 228 243 3.6 4.4 6 156 180 225 210 234 279 u y W x 89.5 220 105.5 245 120.5 290 186.5 200.5 202.5 216.5 217.5 231.5 1) Through-hole for screw 3NP50 65, 160 A with busbar adapter, for busbars 12 mm wide and 5 mm or 10 mm thick M8 22 36 36 134 3NP5. 60, 160 to 630 A with electronic fuse monitoring EFM, with plug connector and control cable 302 165 18 34 63 40 83,5 40 196 63 17 12 31 NSE00236 18 116 156 19 13,5 97,5 45 50 19 NSE00237 3NP50 65, 160 A with busbar adapter, with fuse monitoring by 3RV circuit-breaker, with plug connector 161,5 228 228 3NP50 60, 160 A with electronic fuse monitoring EFM, with plug connector and control cable 102 3NP5. 60, 250 to 630 A with electronic fuse monitoring EFM, with plug connector and control cable y x 299 272 150 136 NSE00238 NSE00239 228 NSE00240 Siemens LV 30 · 2004 6/63 Project planning aids ■ Circuit diagrams Function of auxiliary contacts and main contacts of SENTRIC 3NP4 and 3NP5 ON 1-4 (1 NO) (1 NC) 1-2 3NP40 1, (3 NO) 70° 3NP4.7 0 OFF OFF 0 5 10 20 15 13-14 (1 NO) (1 NC) 21-22 3NP50 60 (3 NO) 5 10 20 15 5 10 20 15 Contact open 77° 13-14 (1 (1 21-22 3NP52 60 (3 3NP53 60 (3 3NP54 60 (3 0 Contact closed NO) NC) NO) NO) NO) Auxiliary switch 2 13 21 4 1 61° 14 22 for 3NP5 for 3NP40 1 and 3NP4.7 SENTRIC 3NP fuse switch disconnector with fuse monitoring (with 3RV1 circuit-breaker, with auxiliary switch 1 NO + 1 NC) Circuit diagram of the main circuit Circuit diagram of the auxiliary circuit 3~ ...Hz ...V L1 L2 L3 L1 1~ ...Hz ...V BU BK F2 F1 13 21 1 3 5 33 41 Q2 Q1 S0 34 42 14 22 33 I> I> I> 2 4 6 Q2 34 NSE00175a K1 F1 N M 3~ K1 Q1 = Fuse switch disconnector Q2 = Circuit-breaker K1 = Contactor S1 = ON button S0 = OFF button F1 = Overload relay F2 = Control-circuit fuse NSE00176a S1 BN WH K1 SENTRIC 3NP5 fuse switch disconnector with electronic fuse monitoring Schematic circuit diagram L1 L2 L3 LED display Running Fault F1 Fault F2 Fault F3 Voltages F1 F2 Microcontroller Resistor network F3 Switching stage Synchronization signals Parameterization Power supply unit 11 L1' L2' 23 24 33 34 L3' NSE00177 Version “A” (open-circuit principle): Auxiliary switches pick up only if fuse defective and voltage is present. Version “R” (closed-circuit principle): Auxiliary contacts pick up as soon as voltage is present and fuses are intact. 6/64 12 Siemens LV 30 · 2004 X1 6 Signal lines BN 5 4 BK BU NSE 00174d ON 3 2 GY WH 1 RD SENTRIC KL and 3KM Switch Disconnectors with Fuses General data ■ Area of application SENTRIC KL and 3KM switch disconnectors with fuses protect against overload and short-circuits as main control and EMERGENCY-STOP switches for switchboards, distribution boards, power supply feeders and motor feeders. In conjunction with Siemens SITOR semiconductor protection fuses, they are also used in UPS systems, frequency converters and capacitor control systems. All SENTRIC K switch disconnectors are climate-proof and meet the requirements of IEC 60947-1, IEC 60947-3 and VDE 0660 Part 107. ■ Design All switch disconnectors feature double contact interruption and an isolating distance. As a result, the fuses are de-energized when the switch disconnectors are in the disconnected position. Generally, all SENTRIC 3K.5 switch disconnectors can be secured on the shaft with a padlock to prevent unauthorized reclosing. The 3KM switch disconnector fuses also feature an isolating plug connector. This facilitates installation and contact establishment in motor control centers (MCCs) in conjunction with vertical busbars. The fact that the accessories for SENTRIC KA, KL and 3KM switch disconnectors with and without fuses are identical simplifies the keeping of stocks. Please inquire about a special variant with reduced values that is particularly resistant to atmospheres high in sulfur, e.g. in the paper and cellulose processing industries. ) 6 % & $ + * ( , $ Can be converted from IEC LV HRC to British Standard BS 88 fuses. % As standard, 3KM switch disconnectors with fuses feature a rear isolating plug connector for use in motor control centers (MCCs). & Switchable 4th pole can easily be fitted later. ( IP20 fuse cover. ) Single-pole IP20 terminal cover from 63 A to 630 A. * Standard products from the Siemens 3SB1 range are used as auxiliary switches. Optional + Selector switch for fixed installation 8UC9 as standard version (black) or as an EMERGENCY-STOP version (red) or , 8UC6 door-coupling rotary operating mechanism with automatic tolerance compensation of ± 5 mm in the horizontal and vertical directions. Standard (black) or EMERGENCY-STOP version (red/yellow). All components from the switch to the operating mechanism have non-interchangeability features. Siemens LV 30 · 2004 6/65 SENTRIC KL and 3KM Switch Disconnectors with Fuses General data ■ Technical specifications Specifications IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Type 3KL50 3KM50 3KL52 3KM52 3KL53 3KM53 3KL551) 3KM551) 3KL571) 3KM571) 3KL611) 3KL621) A 63 Size 00 and 000 125 00 and 000 160 00 and 000 250 1 and 2 400 1 and 2 630 3 and 2 800 3 and 2 Rated uninterrupted current Iu for fuse links to DIN 43620 (the use of semiconductor protection fuse links requires a rated current reduction; see SITOR Configuration catalog, Order No. E20001–A700–P302) Conventional free-air thermal current Ith3) A 63 125 160 250 400 630 800 Rated insulation voltage Ui V 690 1000 1000 1000 1000 1000 1000 8 8 8 8 8 8 Rated impulse withstand voltage Uimp kV 6 Rated operating voltage Ue AC 50 Hz/60 Hz DC V 690 V 440 (3 conducting paths series-connected), 220 (2 conducting paths series-connected) Rated short-circuit making capacity with fuses2) at AC 50 Hz/60 Hz 690 V Rated conditional short-circuit current with fuses2) at AC 50 Hz/60 Hz 690 V Max. rated current In of the fuses kA (peak value) 220 220 220 176 176 105 105 kA (rms value) 100 A 80 100 160 100 160 80 400 80 400 50 630 50 800 Max. permissible power loss of the installed fuse LV HRC BS W 6 W 8 (A2/A3) 9 11.5 (A4) 11.5 11.5 32 32 45 45 48 48 62 60.5 Permissible let-through current of the fuses kA 8 17 17 304) 304) 50 50 2 223 223 1000 1000 5400 10500 Maximum permissible let-through I2 t value kA s 55 Switching capacity (feed-in from the top or bottom) 6 at AC 400 V Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A A (rms value) 500 A 63 kW 30 1000 125 65 1280 160 80 2000 250 132 3200 400 200 5100 6305) 335 6400 8005) 400 at AC 500 V Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A A (rms value) 500 A 63 kW 40 1000 125 90 1280 160 110 2000 250 185 3200 400 280 5100 6305) 425 6400 6305) 500 at AC 690 V Breaking current Ic (p.f. = 0.35) Rated operating current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A A (rms value) 500 A 63 kW 50 1000 125 110 1280 160 150 2000 250 220 3200 400 375 5100 6305) 560 6400 8005) 700 A 250 A 63 500 125 640 160 1006) 2508) 1600 400 25207) 6308) 25207) 6308) kA (rms value) 2.5 3.2 3.2 8 11 32 32 125 125 125 125 125 160 155 150 145 140 250 250 250 250 240 400 390 380 370 360 630 630 610 590 570 800 780 760 740 720 at DC 440 V (3 series-connected current path) Breaking current Ic (L/R = 15 ms) Rated operating current Ie with DC-23A Rated short-time current (1 s current) Permissible load depending on the ambient temperature of the switch for open-type installation in switchboards (e.g. 8NA1), in switchgear panels or switchgear racks at 35 °C 40 °C 45 °C 50 °C 55 °C Permissible ambient temperature Mechanical endurance Required operating torque A A A A A °C –25 ... +55 in operation4), –50 ... +80 when stored Oper. cycles 15000 Nm 3 W 8.5 1) Technical specifications for CSA approval on request. 2) In the case of 3KL61 for operation –25 °C to +35 °C, at +55 °C: Ith = 570 A. 3) Configuring note: max. permissible operating temperature for fuse blades 135 °C, for connections 100 °C. 4) 3ND1 switchgear protection fuse. 5) AC-23B. 6) At 440 V L/R = 4 ms, at 220 V L/R = 15 ms. 7) L/R = 2.5 ms. 8) At 440 V DC-22 A, at 220 V DC-23 A. 6/66 Siemens LV 30 · 2004 15000 15000 12000 12000 3000 3000 7.5 7.5 16 16 30 30 IP00/IP20 (from the operator side, with fuse and terminal covers) Degree of protection Power loss of the switch at Ith (plus power loss of the fuses) 63 63 63 63 63 22 36 33 86 140 225 SENTRIC KL and 3KM Switch Disconnectors with Fuses General data Specifications IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Type 3KL50 3KM50 Main conductor connection Busbar systems, max. dimensions (w × t) Cable lug, max. conductor cross-section (stranded) Tightening torque Terminal screws mm × mm 25 × 9 mm2 35 Nm 6–7.5 M6 PE/ground-conductor connection Flat bars Cable lug, max. conductor cross-section (stranded) Fourth pole for retrofitting (accessory) Rated uninterrupted current Iu Rated operating current Ie at AC-21A, AC 690 V Main conductor connection Flat bars Cable lug, max. conductor cross-section (stranded) mm × mm – mm2 – A – A – mm × mm – mm2 – Auxiliary switch 1 NO + 1 NC (accessory) Max. number to be plugged 1 Rated operating current Ie at AC 50 Hz/60 Hz Ie/AC-12 Ie/AC-15 at Ue = 220 V/230 V Ie/AC-15 at Ue = 380 V/400 V Ie/AC-15 at Ue = 500 V Ie/AC-15 at Ue = 690 V A A A A A 10 6 4 2.5 1.2 Rated operating current Ie with DC Ie/DC-13 at Ue = 24 V Ie/DC-13 at Ue = 48 V Ie/DC-13 at Ue = 110 V Ie/DC-13 at Ue = 220 V Ie/DC-13 at Ue = 440 V A A A A A 10 4 1.2 0.4 0.2 Connection Solid Finely stranded with end sleeve 3KL52 3KM52 3KL53 3KM53 3KL551) 3KM551) 3KL571) 3KM571) 3KL611) 3KL62 45 × 10 70 45 × 10 120 40 × 12 150 40 × 15 2 × 150 or 1 × 240 40 × 17 2 × 240 40 × 17 2 × 240 7–10 M6 18–22 M8 35–45 M 10 35–45 M 10 56 M 12 56 M 12 – – – – 20 × 2.5 70 20 × 2.5 120 – – – – 125 125 125 125 400 400 400 400 – – – – 15 × 3 70 15 × 3 70 25 × 4 240 25 × 4 240 – – – – 2 2 2 2 3 3 6 mm2 2 × (0.5–1.5) mm2 2 × (1–2.5) Weight Complete version 3KL 3KM kg 1.150 kg 1.936 2.560 2.960 2.560 2.960 5.400 7.160 5.700 7.450 – – – – Basic version 3KL 3KM kg 0.850 kg 1.820 2.200 2.600 2.200 2.600 4.500 6.147 4.800 6.443 14.000 – 14.000 – Permissible mounting position 10° 180° 180° 180° NSE00182 3KL, 3KM Note: For the SENTRIC KL switch disconnectors, complete kits for standard and EMERGENCY-STOP application are available for installation in the side and rear panels of control cabinets. Siemens LV 30 · 2004 6/67 SENTRIC KL and 3KM Switch Disconnectors with Fuses Surface and flush mounting ■ Selection and ordering data All switch disconnectors in degree of protection IP00 Conductor connecting screws and fuse partitions are generally included in the scope of delivery. Rated uninterrupted current Iu Fuse links1) to DIN 436202) Size DT Complete version with 8UC6 door-coupling rotary operating mechanism (black handle) Operational class PS* Order No. A Weight per PU approx. kg 3-pole for LV HRC fuses 63 125 160 250 00 and 000 00 and 000 00 and 000 1 and 2 gG, aM gG, aM gG, aM gG, aM B B B B 3KL50 30–1EB01 3KL52 30–1EB01 3KL53 30–1EB01 3KL55 30–1EB01 1 unit 1 unit 1 unit 1 unit 1.460 2.410 2.600 6.110 400 630 800 2 and 1 3 and 2 3 and 2 gG, aM gG, aM gG, aM B B D 3KL57 30–1EB01 3KL61 30–1EB00 3KL62 30–1EB02 1 unit 1 unit 1 unit 6.060 18.000 15.200 3KL52 30–1AB01 4-pole for LV HRC fuses 63 125 160 00 and 000 00 and 000 00 and 000 gG, aM gG, aM gG, aM B B C 3KL50 40–1EB01 3KL52 40–1EB01 3KL53 40–1EB01 1 unit 1 unit 1 unit 2.540 2.620 2.770 250 400 630 1 and 2 2 and 1 3 and 2 gG, aM gG, aM gG, aM B B B 3KL55 40–1EB01 3KL57 40–1EB01 3KL61 40–1EB00 1 unit 1 unit 1 unit 6.640 6.880 16.600 3KL52 40–1AB01 3-pole for fuses to BS 88 6 3KL52 30–1AJ01 63 125 Form A2/A3 Form A2/A3 B B 3KL50 30–1EG01 3KL52 30–1EG01 1 unit 1 unit 1.450 2.360 125 160 Form A4 Form A4 B B 3KL52 30–1EJ01 3KL53 30–1EJ01 1 unit 1 unit 2.400 2.570 250 400 Form B1–B3 Form B1–B3 B B 3KL55 30–1EG01 3KL57 30–1EG01 1 unit 1 unit 6.110 6.580 630 800 Form C1–C3 Form C1–C3 C D 3KL61 30–1EG00 3KL62 30–1EG00 1 unit 1 unit 16.200 15.400 4-pole for fuses to BS 88 63 125 Form A2/A3 Form A2/A3 B B 3KL50 40–1EG01 3KL52 40–1EG01 1 unit 1 unit 2.560 2.560 125 160 Form A4 Form A4 B B 3KL52 40–1EJ01 3KL53 40–1EJ01 1 unit 1 unit 2.610 2.780 250 400 630 Form B1–B3 Form B1–B3 Form C1–C3 B B C 3KL55 40–1EG01 3KL57 40–1EG01 3KL61 40–1EG00 1 unit 1 unit 1 unit 6.630 7.140 16.900 3KL52 40–1AJ01 with fuses Fuse monitoring through 5TT3 170 safety monitor with a floating 1 NO signal contact, see Catalog ET B1 "BETA modular installation devices". 1) Silver-plated fuse blades. Silver-plated isolating links can be used if desired. 2) For use of SITOR semiconductor protection fuse links, see Page 6/89 ff. 6/68 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC KL and 3KM Switch Disconnectors with Fuses Surface and flush mounting All switch disconnectors in degree of protection IP00 Conductor connecting screws and fuse partitions are generally included in the scope of delivery. DT Rated Fuse links1) uninter- to DIN 436202) rupted Size Operacurrent tional class Iu Basic switch version without handle A Order No. PS* Weight DT per PU approx. 8UC6 EMERGENCYSTOP door-coupling rotary operating mechanism (red handle, yellow indicator plate) kg Order No. PS* Weight per PU approx. kg 3-pole for LV HRC fuses 63 125 160 3KL52 30–1AB01 00 and 000 00 and 000 00 and 000 gG, aM } 3KL50 30–1AB01 1 unit 1.050 } 8UC61 21–3BB10 1 unit 0.353 gG, aM } 3KL52 30–1AB01 1 unit 1.980 } 8UC62 22–3BB20 1 unit 0.426 gG, aM } 3KL53 30–1AB01 1 unit 2.200 } 8UC62 22–3BB20 1 unit 0.426 1 unit 5.710 } 1 unit 5.400 } 1 unit 17.600 } } 1 unit 15.200 } } 8UC63 23–3BB30 8UC63 23–3BB30 8UC64 24–3BB44 +8UC92 53 8UC64 24–3BB44 +8UC92 53 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 0.999 0.999 1.180 0.115 1.180 0.115 250 400 630 1 and 2 2 and 1 3 and 2 gG, aM gG, aM gG, aM } } A 3KL55 30–1AB01 3KL57 30–1AB01 3KL61 30–1AB0 800 3 and 2 gG, aM D 3KL62 30–1AB02 gG, aM B 3KL50 40–1AB01 1 unit 2.210 } 8UC62 22–3BB20 1 unit 0.426 gG, aM B 3KL52 40–1AB01 1 unit 2.190 } 8UC62 22–3BB20 1 unit 0.426 gG, aM B 3KL53 40–1AB01 1 unit 2.340 } 8UC62 22–3BB20 1 unit 0.426 gG, aM gG, aM gG, aM B B A 3KL55 40–1AB01 3KL57 40–1AB01 3KL61 40–1AB00 1 unit 5.570 } 1 unit 5.670 } 1 unit 15.400 } } 8UC63 23–3BB30 8UC63 23–3BB30 8UC64 24–3BB44 +8UC92 53 1 unit 1 unit 1 unit 1 unit 0.999 0.999 1.180 0.115 4-pole for LV HRC fuses 63 125 160 3KL52 40–1AB01 250 400 630 00 and 000 00 and 000 00 and 000 1 and 2 2 and 1 3 and 2 3-pole for fuses to BS 88 3KL52 30–1AJ01 63 125 Form A2/A3 Form A2/A3 B B 3KL50 30–1AG01 3KL52 30–1AG01 1 unit 1 unit 0.993 } 1.930 } 8UC61 21–3BB10 8UC62 22–3BB20 1 unit 1 unit 0.353 0.426 125 160 Form A4 Form A4 B B 3KL52 30–1AJ01 3KL53 30–1AJ01 1 unit 1 unit 2.030 } 2.170 } 8UC62 22–3BB20 8UC62 22–3BB20 1 unit 1 unit 0.426 0.426 250 400 Form B1–B3 Form B1–B3 B B 3KL55 30–1AG01 3KL57 30–1AG01 1 unit 1 unit 5.140 } 5.660 } 8UC63 23–3BB30 8UC63 23–3BB30 1 unit 1 unit 0.999 0.999 630 Form C1–C3 A 3KL61 30–1AG00 800 Form C1–C3 D 3KL62 30–1AG00 1 unit 15.000 } } 1 unit 14.200 } } 8UC64 24–3BB44 +8UC92 53 8UC64 24–3BB44 +8UC92 53 1 unit 1 unit 1 unit 1 unit 1.180 0.115 1.180 0.115 4-pole for fuses to BS 88 63 125 Form A2/A3 Form A2/A3 B B 3KL50 40–1AG01 3KL52 40–1AG01 1 unit 1 unit 2.140 } 2.160 } 8UC62 22–3BB20 8UC62 22–3BB20 1 unit 1 unit 0.426 0.426 125 160 Form A4 Form A4 B B 3KL52 40–1AJ01 3KL53 40–1AJ01 1 unit 1 unit 2.120 } 2.230 } 8UC62 22–3BB20 8UC62 22–3BB20 1 unit 1 unit 0.426 0.426 250 400 630 Form B1–B3 Form B1–B3 Form C1–C3 B B C 3KL55 40–1AG01 3KL57 40–1AG01 3KL61 40–1AG00 1 unit 5.660 } 1 unit 6.440 } 1 unit 15.700 } } 8UC63 23–3BB30 8UC63 23–3BB30 8UC64 24–3BB44 +8UC92 53 1 unit 1 unit 1 unit 1 unit 0.999 0.999 1.180 0.115 3KL52 40–1AJ01 with fuses Fuse monitoring through 5TT3 170 safety monitor with a floating 1 NO signal contact, see catalog ET B1 "BETA modular installation devices". 1) Silver-plated fuse blades. Silver-plated isolating links can be used if desired. 2) For use of SITOR semiconductor protection fuse links, see Page 6/89 ff. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/69 6 SENTRIC KL and 3KM Switch Disconnectors with Fuses Front mounting ■ Selection and ordering data All switch disconnectors in degree of protection IP00 Conductor connecting screws and fuse partitions are generally included in the scope of delivery. Rated Fuse links1) uninter- to DIN 436202) rupted Size Operacurrent tional class DT Installation kit (IP40) PS* consisting of: lockable handle, cover for LV HRC fuses (locked in ON state) and three terminal covers for line side Weight DT Basic switch version per PU without handle approx. PS* Weight per PU approx. Iu A Order No. kg Order No. kg 3-pole, kit for mounting in control cabinet side panel Black handle 63 125 160 00 00 00 gG, aM gG, aM gG, aM B B B 3KX3 516–3AA 3KX3 526–3AA 3KX3 536–3AA 1 unit 1 unit 1 unit 0.626 } 0.820 } 0.880 } 3KL50 30–1AB01 3KL52 30–1AB01 3KL53 30–1AB01 1 unit 1 unit 1 unit 1.050 1.980 2.200 250 400 1 and 2 2 and 1 gG, aM gG, aM B B 3KX3 556–3AA 3KX3 556–3AA 1 unit 1 unit 1.720 } 1.720 } 3KL55 30–1AB01 3KL57 30–1AB01 1 unit 1 unit 5.710 5.400 EMERGENCY-STOP red handle 6 63 125 160 00 00 00 gG, aM gG, aM gG, aM B B B 3KX3 516–3BA 3KX3 526–3BA 3KX3 536–3BA 1 unit 1 unit 1 unit 0.625 } 0.846 } 0.883 } 3KL50 30–1AB01 3KL52 30–1AB01 3KL53 30–1AB01 1 unit 1 unit 1 unit 1.050 1.980 2.200 250 400 1 and 2 2 and 1 gG, aM gG, aM B B 3KX3 556–3BA 3KX3 556–3BA 1 unit 1 unit 1.690 } 1.690 } 3KL55 30–1AB01 3KL57 30–1AB01 1 unit 1 unit 5.710 5.400 Fuse monitoring through 5TT3 170 safety monitor with a floating 1 NO signal contact, see catalog ET B1 "BETA modular installation devices". 1) Silver-plated fuse blades. Silver-plated isolating links can be used if desired. 2) For use of SITOR semiconductor protection fuse links, see Page 6/89 ff. 6/70 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC KL and 3KM Switch Disconnectors with Fuses For plugging into busbar system ■ Selection and ordering data All switch disconnectors in degree of protection IP00 Mounting on vertical busbars with busbar center-to-center distance of 60 mm and bar thickness from 5 mm to 6.35 mm Conductor connecting screws and fuse partitions are generally included in the scope of delivery DT Rated Fuse links1) uninter- to DIN 436202) rupted Size Operacurrent tional class Iu PS* Order No. A Weight DT per PU approx. Basic switch version without handle kg Order No. PS* Weight per PU approx. kg 3-pole for LV HRC fuses Complete version with 8UC6 door-coupling rotary operating mechanism (black handle) 63 125 160 3KM53 30–1AB01 with fuses 250 400 00 and 000 00 and 000 00 and 000 1 and 2 2 and 1 gG, aM B 3KM50 30–1EB01 1 unit 1.890 B 3KM50 30–1AB01 1 unit 1.510 gG, aM B 3KM52 30–1EB01 1 unit 2.860 B 3KM52 30–1AB01 1 unit 2.450 gG, aM B 3KM53 30–1EB01 1 unit 2.930 B 3KM53 30–1AB01 1 unit 2.510 gG, aM gG, aM B B 3KM55 30–1EB01 3KM57 30–1EB01 1 unit 1 unit 5.670 B 6.930 B 3KM55 30–1AB01 3KM57 30–1AB01 1 unit 1 unit 5.690 5.960 8UC6 EMERGENCY-STOP door-coupling rotary operating mechanism (red handle, yellow indicator plate) 63 125 160 250 400 00 and 000 00 and 000 00 and 000 gG, aM } 8UC61 21–3BB10 1 unit 0.353 B 3KM50 30–1AB01 1 unit 1.510 gG, aM } 8UC62 22–3BB20 1 unit 0.426 B 3KM52 30–1AB01 1 unit 2.450 gG, aM } 8UC62 22–3BB20 1 unit 0.426 B 3KM53 30–1AB01 1 unit 2.510 1 and 2 2 and 1 gG, aM gG, aM } } 8UC63 23–3BB30 8UC63 23–3BB30 1 unit 1 unit 0.999 B 0.999 B 3KM55 30–1AB01 3KM57 30–1AB01 1 unit 1 unit 5.690 5.960 3-pole for fuses to BS 88 Complete version with 8UC6 door-coupling rotary operating mechanism (black handle) 3KM55 30–1AG01 with fuses 63 125 Form A2/A3 Form A2/A3 C C 3KM50 30–1EG01 3KM52 30–1EG01 1 unit 1 unit 1.800 C 2.780 C 3KM50 30–1AG01 3KM52 30–1AG01 1 unit 1 unit 1.450 2.400 125 160 Form A4 Form A4 C C 3KM52 30–1EJ01 3KM53 30–1EJ01 1 unit 1 unit 2.340 C 2.920 C 3KM52 30–1AJ01 3KM53 30–1AJ01 1 unit 1 unit 2.430 2.520 250 400 Form B1–B3 Form B1–B3 C B 3KM55 30–1EG01 3KM57 30–1EB01 1 unit 1 unit 6.650 C 6.930 C 3KM55 30–1AG01 3KM57 30–1AG01 1 unit 1 unit 5.680 6.250 8UC6 EMERGENCY-STOP door-coupling rotary operating mechanism (red handle, yellow indicator plate) 63 125 Form A2/A3 Form A2/A3 } } 8UC61 21–3BB10 8UC62 22–3BB20 1 unit 1 unit 0.353 C 0.426 C 3KM50 30–1AG01 3KM52 30–1AG01 1 unit 1 unit 1.450 2.400 125 160 Form A4 Form A4 } } 8UC62 22–3BB20 8UC62 22–3BB20 1 unit 1 unit 0.426 C 0.426 C 3KM52 30–1AJ01 3KM53 30–1AJ01 1 unit 1 unit 2.430 2.520 250 400 Form B1–B3 Form B1–B3 } } 8UC63 23–3BB30 8UC63 23–3BB30 1 unit 1 unit 0.999 C 0.999 C 3KM55 30–1AG01 3KM57 30–1AG01 1 unit 1 unit 5.680 6.250 Fuse monitoring through 5TT3 170 safety monitor with a floating 1 NO signal contact, see catalog ET B1 "BETA modular installation devices". 1) Silver-plated fuse blades. Silver-plated isolating links can be used if desired. 2) For use of SITOR semiconductor protection fuse links, see Page 6/89 ff. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/71 6 SENTRIC KL and 3KM Switch Disconnectors with Fuses Accessories ■ Selection and ordering data DT 3KL50 30/3KM50 PS* Order No. Terminal cover (1 set = 6 units) for 3-pole devices 3KX3 5.7–3AA (1 set = 8 units) for 4-pole devices } 3KX3 552–3DA01 1 set Weight DT per PU approx. 3KL50 40/3KL52/ 3KL53/3KM52/3KM53 kg Order No. 0.077 } } 6 kg 1 set 0.077 1 set 0.147 1 set 0.102 3KX3 552–3DB01 1 set 0.102 B 1 set 0.170 Fuse cover2) (interlock only detachable in the OFF position) } 3KX3 517–3AA 1 unit 0.041 } 3KX3 527–3AA 1 unit 0.071 Fuse partition (1 set = 5 units) } 3KX3 507–0AA01 1 set 0.044 } 3KX3 507–0AA01 1 set 0.044 Lyre-shaped fuse cover (1 set = 6 units) B 3KX3 507–0BA01 1 set 0.033 B 3KX3 507–0BA01 1 set 0.033 Door-coupling rotary operating mechanism IP65 black handle, shaft 300 mm } 8UC61 11–1BB10 1 unit 0.347 } 8UC62 12–1BB20 1 unit 0.404 Door-coupling rotary operating mechanism IP65 EMERGENCY-STOP (yellow/red), shaft 300 mm } 8UC61 21–3BB10 1 unit 0.353 } 8UC62 22–3BB20 1 unit 0.426 Operating mechanism for fixed mounting black handle, shaft 250 mm } 3KX3 516–1AA 1 unit 0.088 } 3KX3 536–1AA 1 unit 0.155 Extension shaft 300 mm long B 8UC60 31 1 unit 0.068 B 8UC60 32 1 unit 0.132 Extension shaft 600 mm long B 8UC60 81 1 unit 0.136 B 8UC60 82 1 unit 0.265 Shaft connection piece B 8UC60 21 1 unit 0.031 B 8UC60 22 1 unit 0.023 Auxiliary switches 1 NO + 1 NC1) A 3SB14 00–0A 1 unit 0.019 A 3SB14 00–0A 1 unit 0.019 3KX3 552–3EA01 1 unit 0.019 1 set 0.014 B 3KX3 505–0AA 1 set 0.014 20 ms leading 1 NO + 1 NC 3SB14 00–0A 3KA52 3KX3 552–3DB01 3KA53 3KX3 553–3DB01 Weight per PU approx. B B 3KX 507–0BA 3KA52 3KX3 552–3DA01 3KA53 3KX3 553–3DA01 PS* Fuse monitor connection (1 set = 6 units) B – B 3KX3 505–0AA 1) For further 3SB14 00–0 switching elements with other contact types, see “Pushbuttons and Indicator Lights". 2) For 3KX3 527–3AA: not suitable for use with type A BS fuses. 6/72 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC KL and 3KM Switch Disconnectors with Fuses Accessories DT 3KL55/3KL57/ 3KM55/3KM57 PS* Order No. Terminal cover (1 set = 6 units) for 3-pole devices 3KX3 5.7–3AA 3KX3 176–1E Order No. Weight per PU approx. kg 1 set 0.277 } 3KX3 561–3DA01 1 set 0.263 (1 set = 8 units) for 4-pole devices B 3KX3 557–3DB01 1 set 0.362 B 3KX3 561–3DB01 1 set 0.365 Fuse cover2) (interlock only detachable in the OFF position) } 3KX3 557–3AA 1 unit 0.212 – 3KX3 561–0AA00 3KX3 561–1AA00 1 unit 1 unit 0.408 0.408 3KY3 612–0A 1 set 0.179 8UC64 14–1BB44 1 unit 1.170 +8UC92 53 1 unit 0.115 8UC64 24–3BB44 1 unit 1.180 +8UC92 53 1 unit 0.115 C D – – } 3KX3 557–0AA01 1 set 0.162 A Lyre-shaped fuse cover (1 set = 6 units) – Door-coupling rotary operating } mechanism IP65 black handle, square shaft 300 mm 8UC63 13–1BB30 1 unit 0.973 } Door-coupling rotary operating mechanism IP65 EMERGENCY-STOP (yellow/red), square shaft 300 mm } 8UC63 23–3BB30 1 unit 0.999 } Operating mechanism for fixed mounting black handle, shaft 250 mm } 3KX3 176–1E 1 unit 0.285 } 3KX3 616–1A 1 unit 0.490 Extension shaft 300 mm long C 8UC60 33 1 unit 0.217 B 8UC60 34 1 unit 0.315 Extension shaft 600 mm long B 8UC60 83 1 unit 0.430 B 8UC60 84 1 unit 0.640 Shaft connection piece B 8UC60 23 1 unit 0.085 B 8UC60 24 1 unit 0.077 Auxiliary switches 1 NO + 1 NC1) A 3SB14 00–0A 1 unit 0.019 D 3KX3 612–1A 1 unit 0.201 B 3KX3 552–3EA01 1 unit 0.019 – B 3KX3 505–0AA 1 set 0.014 – 20 ms leading 1 NO + 1 NC 3SB14 00–0A kg PS* 3KX3 557–3DA01 Fuse partition (3KX3 557–0AA01: 1 set = 5 units, 3KY3 612–0A: 1 set = 4 units) 8UC92 53 3KL61/3KL62 } Fuse cover Cover plate Complete cover 3KX3 507–0BA Weight DT per PU approx. Fuse monitor connection (1 set = 6 units) – } } 1) For further 3SB14 00–0 switching elements with other contact types, see “Pushbuttons and Indicator Lights". 2) For 3KX3 527–3AA: Not suitable for use with type A BS fuses. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/73 6 SENTRIC KL and 3KM Switch Disconnectors with Fuses Project planning aids ■ Dimension drawings 3KL50, 63 A, 3-pole; Dimension drawing for 4-pole version corresponds to dimension drawing for 3KL52; without operating mechanism, with lyre-shaped contacts 3KL50, 63 A with shaft and 8UC6 operating mechanism 42 - 50 6 22,5 15 36 NSE00275 1) Æ 4,5 100 90 90 105 30 43,5 1,5...4 66 Æ 4,5 75 65 a 2 23 NSE00291 NSE00274 4,5 Æ 6,6 25 22,5 32,5 120 M 6x20 135 150 1) To be kept free of conductive parts. Not necessary when using lyre-shaped contacts or covers (accessory). 3KL50, 30, 63 A 3-pole; Dimension drawing for 4-pole version corresponds to dimension drawing for 3KL52; without operating mechanism, for BS fuses 4,5 Shaft length max. 380 300; unchanged shaft from 8UC61 min. 175 175–80; shortened shaft from 8UC61 ≥ 175 ... ≤ 380 a–80 R2 6-0,1 Shaft (profile) Engaged length: min. 70 mm max. 150 mm 15 71,5 2 M 6x20 135 150 3KL52, 125 A, 3KL53, 160 A, 3KL50, 63 A, 4-pole without operating mechanism, with lyre-shaped contacts 55 143 c 55 85 63 i l g 149 e g h i c d 3KL52 NH 3KL53 NH 15 20 M 6 × 20 37 M 8 × 25 39 42 91 3 39.5 105 3.5 ∅ 6.6 – ∅9 – 3KL52 A2/A3 15 3KL53 A4 20 M 6 × 20 37 M 8 × 25 39 42 91 3 39.5 105 3.5 ∅ 6.6 71.5 106 ∅ 9 96 125 4th pole M 6 × 20 – 48 ∅ 6.6 – 91 3 l 143 m * To be kept free of conductive parts. Not necessary when using lyre-shaped contacts or covers (accessory). n 100 e 90 185 25 5 149 Fourth pole 3KX3 523–0AA for 3KL52, 3KL53 46 106 125 106 d 38 16,5 N N l 215 30 h n Type 15 m 100 NSE00278 38 5 NSE00279b e 90 185 i l 110 100 n h 25 g c 35 39 63 15 35 39 85 22,5 * 15 3KL52, 125 A, 3KL53, 160 A, 3KL50, 63 A, 4-pole without operating mechanism, for BS fuses 110 23 NSE00276a 4,5 6,6 25 22,5 32,5 120 NSE00277 6 90 90 105 30 43,5 a c 3KL52, 125 A 3KL53, 160 A with shaft and 8UC6 operating mechanism NSE00280 60 42 - 50 8 1,5...4 66 75 4,5 a 6/74 Siemens LV 30 · 2004 65 NSE00281 a Shaft length max. 350 300; unchanged shaft from 8UC62 min. 165 165–50; shortened shaft from 8UC62 ≥ 165 ... ≤ 350 a–50 R2 8 -0,1 Shaft (profile) Engaged length: min. 70 mm max. 150 mm SENTRIC KL and 3KM Switch Disconnectors with Fuses Project planning aids 3KL55, 250 A 3KL57, 400 A without operating mechanism, with lyre-shaped contacts 26,5 107 65 25 11 a 207 b c 16 Type a b c 3KL55 3KL57 40 38 4 6 M 10 × 30 M 10 × 35 4th pole 80 4 M 10 × 30 130 135 160 41 86 7 NSE00282 NSE00283 7 20 17 100 240 11 3 Shaft (profile) Engaged length*): min. 170 mm max. 205 mm R2 195,5 (Gr.1) 203,5 (Gr.2) 209 10 -0,1 3KL55, 250 A 3KL57, 400 A with shaft and 8UC6 operating mechanism 140 NSE00284 63 - 65 10 a Shaft length max. 335 300; unchanged shaft from 8UC63 min. 230 230–35; shortened shaft from 8UC63 ≥ 230 ... ≤ 335 a–35 1,5...4 100 88 5,5 88 a 6 Fourth pole 3KX3 553–0AA for 3KL55, 3KL57 55,5 100 135 160 N N 293 *) According to the label on the switch and the operating instructions for 3K.55, 57, 58, engaged lengths of min. 160 mm to max. 207 mm are possible. In the catalog, however, these specifications have been limited to min. 170 mm to max. 205 mm. NSE00285a 25 53 c 3KL61, 630 A 3KL62, 800 A without operating mechanism, with lyre-shaped contacts, with partitions 9 4th pole for 3KL61 345 315 20,5 95 1 NSE00905a 12 95,5 40 87 87 100 155 194 280 230 208 270 180 26 78 NSE00286 29 M 12 234 239 240 74,5 66,5 399 40 12,5 Total installation depth with handle: 239 + 74.5 + 66.5 = 370 $ Profile 12 × 12, Shaft length 110, Shaft can be turned by 45° Siemens LV 30 · 2004 6/75 SENTRIC KL and 3KM Switch Disconnectors with Fuses Project planning aids 3KM50, 63 A with shaft and 8UC6 operating mechanism 3KM50, 63 A without operating mechanism, with lyre-shaped contacts 36 42 - 50 43,5 6 120 22,51) 100 4,5 75 65 134 135 66 23 206 a min. 175 175–80; shortened shaft from 8UC61 ≥ 175 ... ≤ 380 a–80 25 25 90 60 2 135 5,5 206 23 172 60 25 89 31 40 6 90 R2 175 6-0,1 Shaft (profile) Engaged length: min. 70 mm Shaft centre 1) Keep this space free of conductive parts. Not necessary when using lyre-shaped contacts (included in the scope of supply) or covers (accessory). M 6x20 7,5 40 60 9 5,5 NSE00289a 60 5-6,4 M 6x20 7,5 NSE00291 25 25 150 71 42 3KM52, 125 A 3KM53, 160 A with shaft and 8UC6 operating mechanism 60 42 - 50 3KM52, 125 A 3KM53, 160 A without operating mechanism, with lyre-shaped contacts (further dimensions as for 3KL52 and 3KL53) 22,5 1) 8 100 75 4,5 65 max. 350 300; unchanged shaft from 8UC62 min. 165 165–50; shortened shaft from 8UC62 ≥ 165 ... ≤ 350 a–50 e 25 60 Type c 3KM52 15 3KM53 20 Siemens LV 30 · 2004 172 185 5-6,4 60 25 NSE00293a Shaft length g c a 6/76 l i 66 145 143 1,5...4 a 149 NSE00292 70 41 6 89 NSE00290 100 5,5 25 25 90 25 60 172 40 60 9 Drilling pattern and connector cutout 3KM50, 63 A without operating mechanism, for BS fuses 120 5-6,4 NSE00288a Shaft length 300; unchanged shaft from 8UC61 71 42 a max. 380 43,5 2 1,5...4 150 NSE00287 107 e g i l 37 39 42 39.5 3 3.5 ∅ 6.6 ∅9 SENTRIC KL and 3KM Switch Disconnectors with Fuses Project planning aids Drilling pattern and cutout in the mounting plate for flush mounting of 3KM52 3KM52, 125 A 3KM53, 160 A without operating mechanism, for BS fuses 96 Cutout in the mounting plate 60 Type c NSE00296a 25 60 NSE00295a 5-6,4 172 185 3KM52 15 3KM53 20 60 90 NSE00294a 70 41 e 25 5,5 25 25 g c Shaft centre 35 l i 149 143 6 31 175 107 e g i l 37 39 42 39.5 3 3.5 ∅ 6.6 ∅9 Shaft (profile) Engaged length: 90 mm max. 143 mm R2 min. 63 - 65 140 10 1,5...4 88 100 5,5 7 240 88 a Shaft length 300; unchanged shaft from 8UC63 min. 230 230–35; shortened shaft from 8UC63 ≥ 230 ... ≤ 335 a–35 25 60 25 60 Type x y z 3KM55 4 40 M 10 × 30 3KM57 6 38 M 10 × 36 31 64 20 12 NSE00283 R2 Cutout in the mounting plate 175 24 220 10 -0,1 Shaft (profile) Engaged length*): min. 170 mm max. 205 mm Shaft centre 31,5 75 17,5 200 6,5 25 41 100 7 NSE00301a NSE00299 60 82 30 185 z Drilling pattern and cutout in the mounting plate for flush mounting of 3KM55 and 3KM57 3KX3 508–0AA busbar holder for 30 mm × 5 mm busbars 60 5 172 5-6,4 NSE00298a 70 41 y a max. 335 6 160 207 NSE00297 3KM55, 250 A 3KM57, 400 A without shaft, without operating mechanism, with lyre-shaped contacts (further dimensions as for 3KL55) x 195,5 (Gr.1) 203,5 (Gr.2) 3KM55, 250 A 3KM57, 400 A with shaft and 8UC6 operating mechanism 209 8 - 0,1 *) According to the label on the switch and the operating instructions for 3K.55, 57, 58, engaged lengths of min. 160 mm to max. 207 mm are possible. In the catalog, however, these specifications have been limited to min. 170 mm to max. 205 mm. Siemens LV 30 · 2004 6/77 SENTRIC KL and 3KM Switch Disconnectors with Fuses Project planning aids Mounting holes for 3K . 50, 3KA51 with 3KX3 516–... rear manual operating mechanism 22,5 5,8 NSE00304 12 4,8 NSE00302 Mounting holes for 3K . 55, 3K . 57, 3K . 58 with 3KX3 556–... rear manual operating mechanism 56 Mounting holes for 3K . 52, 3K . 53 with 3KX3 526–.../3KX3 536–... rear manual operating mechanism 22,5 68 4,8 4,8 5,8 60 NSE00303 5,8 22,5 56 ■ Circuit diagrams Circuit diagram for SENTRIC KL Circuit diagram for 3KM NSE00184 1 3 5 13 11 23 21 14 12 24 22 2 4 6 (For 3KL50 and 3KL51, only one auxiliary switch possible, not included in scope of supply; fourth pole as main contact possible) Circuit diagram for SENTRIC KL P N 3 1 5 * ) 2 4 6 N S E 0_01389 6 (auxiliary switch not included in scope of supply) Use for DC voltage at DC-23A 440 V *) Isolating link: When switching DC voltages, only one fuse is required for the plus pole. Use of a second fuse will result in additional power loss and an undesired temperature rise in the switchboards. 6/78 Siemens LV 30 · 2004 (for 3KM50 and 3KM51, only one auxiliary switch possible) SENTRIC NJ In-Line Fuse Switch Disconnectors General data ■ Benefits Parking position All SENTRIC 3NJ in-line fuse switch disconnectors are fed via the busbars. The outgoing current is transported via cable (see "Terminal positions"). For maintenance purposes, for example, the carriers of the single-pole in-line fuse switch disconnectors of sizes 1 to 3 and the three-pole in-line fuse switch disconnectors of size 00 can be mounted after being turned by 180° (fuse facing outwards). With SENTRIC 3NJ41 in-line fuse disconnectors it is possible to choose between having the cable connection on top or on bottom (standard version) by turning the contact carrier. The upper part can be removed completely. This ensures easy installation. This results in the following advantages: • Visible disconnection point • Depot for fuse links (parking position) • No opportunity for mistakes on replacing the fuse links • Additional touch protection in the vicinity of the lyre-shaped contacts Inspection holes SENTRIC 3NJ41 and 3NJ56 single-pole and three-pole in-line fuse switch disconnectors are designed for installation in lowvoltage distribution boards, substations and cable distribution cubicles. They are suitable for use in any climate. In an open position, they are safe from touch by the back of the hand (exception 3NJ56: IP00). When the fuse carriers are closed, the degree of protection for all in-line fuse switch disconnectors is IP30. They comply with the following regulations: IEC 60408, IEC 60947-3 and VDE 0660 Part 107. Fuse links in compliance with DIN 43620 Part 1 can be used – nickel-plated fuse blades are not permissible due to the high transfer resistance. ■ Design Mounting position The SENTRIC 3NJ in-line fuse switch disconnectors can be mounted vertically or horizontally. When fitted horizontally, however, system-specific reduction factors and the coincidence factor (DIN VDE 0660 Part 500 4.7) according to the applicable system regulations must be observed. Terminals L1 L2 L3 NSK-6473 ■ Area of application For voltage testing, all SENTRIC 3NJ in-line fuse switch disconnectors are fitted with voltage test apertures. 6 L1 L2 L3 Terminal position Special blocks 3NJ41 21 3NJ41 31 3NJ41 41 3NJ41 23 3NJ41 33 3NJ41 43 3NJ41 03 The 3NJ4 and 3NJ5 in-line devices are also available on request for the following applications: • In-line feed-in device for 1600 A: two parallel-connected size 3 in-line devices with isolating links fitted instead of the LV HRC fuses (only 1-pole switching) • In-line busbar isolating devices with side feeders for isolating or connecting two busbar systems (sizes 1 to 3) • Parallel-connected in-line devices for 800 A or 1250 A (only 1-pole switching) ■ Integration Assembly kits as well as TTA modules and partly equipped sideby-side cabinets are available for installation in the SIKUS 3200 (8GG) modular distribution board system; see Components for distribution systems. 3NJ41 in-line fuse switch disconnectors The SENTRIC 3NJ in-line fuse switch disconnectors for mounting on 185 mm busbar systems are available in the following versions and sizes: Installation in SIKUS Universal (8GF) is also possible. Please inquire. Size 1 for 250 A, 1- or 3-pole switchable Size 2 for 400 A, 1- or 3-pole switchable Size 3 for 630 A, 1- or 3-pole switchable Size 4a for 1250 A, 1-pole switchable The size 00, 160 A three-pole in-line fuse disconnectors are available for 100 mm busbar center-to-center distance and only as a special version for 185 mm busbar center-to-center distance. Instead of one size 1 to 3 disconnector, two size 00 disconnectors with an adapter and masking frame can be used (see Accessories) on a 185 mm busbar system. The swiveling mechanism with three-pole switchable disconnectors of sizes 1 to 3 is lockable and ensures simultaneous switching of all three phases. Siemens LV 30 · 2004 6/79 SENTRIC NJ In-Line Fuse Switch Disconnectors General data ■ Technical specifications Specifications IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Type 3NJ41 0 3NJ5 0 3NJ41 2 3NJ41 3 3NJ41 4 3NJ41 8 3NJ41 5 3NJ56 A 160 A 160 250 225 400 360 630 567 910 – 1000 – 1250 – Rated insulation voltage Ui V 750 1000 1000 1000 500 1000 1000 Rated operating voltage Ue AC 40 Hz ...60 Hz V 690 690 690 690 400 690 690 kA (rms value) 50 A 160 50 250 50 400 50 630 50 910 – – 50 1250 28 39 52 53 – 80 1/250 1 and 2/250 and 400 2 and 3/400 and 630 3/910 – 4a/1250 160 160 160 100 160 250 250 250 200 250 400 400 400 315 400 630 630 630 500 630 910 – – – – 1000 1000 1000 600 – 1250 1250 1250 – – A 480 A 380 A 240 750 600 375 1200 945 600 1890 1500 945 – – – 2400 – – 3750 – – 105–115 155–185 250–300 – – – 20 22 22 22 22 34 Conventional thermal current free air Ith1) enclosed Ithe2) Rated conditional short-circuit current with fuses at AC 40 Hz to 60 Hz 690 V max. rated current In of the fuses Permissible let-through current of the fuses kA (peak value) 15 For fuse links to IEC 60269-2-1 or isolating links Size/A 00/160 Rated operating current Ie at AC 400 V at AC 500 V at AC 690 V at AC 690 V at DC 220 V AC-22B AC-22B AC-21B AC-22B DC-21B A A A A A Rated switching capacity at AC 500 V at AC 690 V at DC 220 V 6 p.f. = 0.65 p.f. = 0.65 L/R = 1 ms kvar 50–60 Capacitive switching capacity Rated short-time current (1 s current) kA (rms value) 15 °C –25 ... +55 Permissible ambient temperature Mechanical endurance Oper. cycles 1400 1400 800 800 800 800 800 Electrical endurance Oper. cycles 200 200 200 200 100 100 100 IP30 IP30 IP30 IP30 IP30 IP30 IP10 IP10 IP10 IP10 IP10 IP10 IP10 IP10 23 49 110 260 300 300 M 10 42 240 M 12 42 240 M 12 42 2403) 2 × M 12 80 2 × 240 2 × M 12 80 2 × 240 M 16 80 2 × 300 Degree of protection With closed fuse carrier, with terminal cover and peripheral cover With open fuse carrier Power loss of the main conducting paths at Ith Main conductor connection Terminal screws Flat bars Cable lug, max. conductor cross-section (stranded) Tightening torque Terminal clamp/V terminals Fixing screws for fitting on busbars Required tightening torque W 18 M8 mm 24 2 mm 95 Nm 10–15 30–35 30–35 30–35 30–35 30–35 50–60 mm2 1.5–70 25–300 25–300 25–300 – – – M8 Nm 16–18 M 12 35–40 M 12 35–40 M 12 35–40 M 12 35–40 M 12 35–40 M 16 50–60 1) When several units are used next to each other the load factor acc. to EN 60439 Part 1/DIN VDE 0660 Part 500, Table 1 must be observed. 2) Required enclosure volume is at least 0.185 m3. 3) A special kit is required for connection of 2 × 240 mm2; delivery details on request. 6/80 Siemens LV 30 · 2004 SENTRIC NJ In-Line Fuse Switch Disconnectors 1-pole switchable, 3-pole switchable ■ Selection and ordering data Rated uninterrupted current Ius For fuse links acc. to DIN 43620 A Size Center-tocenter distance Connection type (terminal screws/ clamp-type terminals included in the scope of supply)1), optionally top or bottom (rotatable) For conductor cross-section DT Order No. PS* mm2 mm Weight per PU approx. kg In-line fuse switch disconnectors, single-pole operation 160 00 and 000 185 M 8 flat connector – A 3NJ50 13–0BD00 1 unit 2.560 250 1 M 10 flat connector – A 3NJ41 21–3BF01 1 unit 5.280 M 12 stud terminal – A 3NJ41 21–3BJ01 1 unit 5.310 V terminal Cu/Al 25–150 and 185–300 D 3NJ41 21–3BT01 1 unit 5.720 400 630 1250 2 and 1 3 and 2 a4 185 185 185 185 M 12 flat connector – A 3NJ41 31–3BF01 1 unit 5.360 M 12 stud terminal – A 3NJ41 31–3BJ01 1 unit 5.300 V terminal Cu/Al 25–150 and 185–300 A 3NJ41 31–3BT01 1 unit 5.680 M 12 flat connector – A 3NJ41 41–3BF01 1 unit 6.090 M 12 stud terminal – A 3NJ41 41–3BJ01 1 unit 6.070 V terminal Cu/Al 25–150 and 185–300 A 3NJ41 41–3BT01 1 unit 6.420 M 16 × 60 stud terminal – A 3NJ56 43–0BB00 1 unit 20.500 In-line fuse switch disconnectors, three-pole operation 160 250 400 630 00 and 000 100 1 2 and 1 3 and 2 185 185 185 } 3NJ41 03–3BF01 1 unit 1.430 Clamp-type terminal 1.5 – 70 A 3NJ41 03–3BK01 1 unit 1.420 Prismatic-type terminal Cu/Al 10 – 70 A 3NJ41 03–3BL01 1 unit 1.470 M 8 flat connector – M 10 flat connector – } 3NJ41 23–3BF01 1 unit 5.480 M 12 stud terminal – A 3NJ41 23–3BJ01 1 unit 5.510 V terminal Cu/Al 25–150 and 185–300 A 3NJ41 23–3BT01 1 unit 5.900 M 12 flat connector – } 3NJ41 33–3BF01 1 unit 5.540 M 12 stud terminal – A 3NJ41 33–3BJ01 1 unit 5.580 V terminal Cu/Al 25–150 and 185–300 A 3NJ41 33–3BT01 1 unit 5.890 M 12 flat connector – } 3NJ41 43–3BF01 1 unit 6.420 M 12 stud terminal – A 3NJ41 43–3BJ01 1 unit 6.320 V terminal Cu/Al 25–150 and 185–300 A 3NJ41 43–3BT01 1 unit 6.670 Incoming block, single- or 3-pole operation, flat connector 2 × M 12 1000 910 3 3 185 185 for supply from cable directly to busbars, with fixed disconnecting blades2), corresponds to block size 3 1-pole operation A 3NJ41 51–5BD01 1 unit 9.870 3-pole operation C 3NJ41 53–5BD01 1 unit 11.000 for supply from 630 kVA transformer to the busbar system; for special transformer protection fuses (see Accessories) 1-pole operation D 3NJ41 81–3BF01 1 unit 6.800 3-pole operation A 3NJ41 83–3BF01 1 unit 12.900 Further special designs on request, see Page 6/79. 1) Fixing screws should be ordered separately. 2) Retrospective exchange with fuse links of size 3 is possible. Thereby reduction of the rated current to 630 A. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/81 6 SENTRIC NJ In-Line Fuse Switch Disconnectors Accessories ■ Selection and ordering data For in-line fuse DT switch disconnectors or dimensions Order No. PS* Weight per PU approx. kg 3NJ49 12–1AA01 3NJ49 12–1DA00 Cover1) size 1 to 3 3NJ41 2 to Additional touch protection with use of cable lugs or connection 3NJ41 4 from above } 3NJ49 12–1AA01 1 unit 0.103 Cover size 00 (also suitable as compensating cover) top and bottom (1 set = 2 units: short and long 2) for covering of extended cable lugs and for combining 3NJ41 03 with 3NJ41 2 to 3NJ41 4 in-line disconnectors 3NJ41 03 } 3NJ49 12–1DA00 1 set 0.125 Blanking cover for panel cutout acc. to the size of the switch disconnectors: sizes 1 to 3 (for fitting in the cutout of the control panels) 50 mm wide 100 mm wide A A 3NJ49 12–2AA00 3NJ49 12–2BA00 1 unit 1 unit 0.189 0.215 Fixing clips (1 set = 4 units, including fixing accessories) 2 units per side, for fixing the cover of the control panel front 3NJ41 A 3NJ49 18–0AA00 1 set 0.145 Unequipped section cover for busbars Busbar center-to-center distance 185 mm 50 mm wide 100 mm wide A 3NJ49 12–3AA00 3NJ49 12–3BA00 1 unit 0.148 50 mm wide A 3NJ49 12–3CA00 1 unit 0.105 Busbar center-to-center distance 100 mm3) (To be fitted directly in the drilled holes of the busbars) 6 NSE00178 3NJ49 18–0DA00 Adapter for fitting of two 3NJ41 03 in-line disconnectors (= 1 carrier) onto a busbar system with 185 mm center-to-center distance (incl. adaptation of the installation depth to that of the 3NJ41 2 to 3NJ41 4 in-line disconnectors) 3NJ41 03 } 3NJ49 18–0DA00 1 unit 0.751 two 3NJ50 13 in-line disconnectors (= 1 carrier) (to adapt the overall depth to that of the strips, sizes 1 to 3) 3NJ50 13 C 3NJ59 30–3BB 1 unit 0.675 one 3NJ41 03 in-line disconnector (= 3 separate brackets) onto a busbar system with 60 mm center-to-center distance 3NJ41 03 A 3NJ49 18–0EA00 1 unit 0.232 1) With cable lugs and connection from above, the terminal cover can be extended by connecting two pieces together. 2) Can be shortened (in exchange for short cover, included in the scope of supply of the in-line disconnector). 3) Also for covering a blank space on 3NJ49 18–0DA00 or 3NJ59 30–3BB. 6/82 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SENTRIC NJ In-Line Fuse Switch Disconnectors Accessories For in-line fuse DT switch disconnectors or dimensions Order No. PS* Weight per PU approx. Busbar support for 100 mm and 185 mm center-to-center distance for screwing on of busbars 3NJ41 and 3NJ5 } 3NJ59 74–0AB 1 unit 0.443 Busbar terminal 3NJ41 03 } 3NJ49 11–3AA00 1 set 0.175 (1 set = 3 units) for rapid fitting of the in-line disconnectors to the busbars 3NJ41 2 to 3NJ41 4 } 3NJ49 11–3BA01 1 set 0.607 Saddle terminal assembly kit (1 set = 3 units) Copper terminal 1.5 mm2 to 70 mm2 3NJ41 03 A 3NJ49 11–4AA00 1 set 0.041 Prism terminal assembly kit (1 set = 3 units) Al/Cu terminal 10 mm2 to 70 mm2 3NJ41 03 C 3NJ49 11–1AA00 1 set 0.098 Box terminal block (1 set = 3 units) Al/Cu terminal 95 mm2 to 240 mm2 (for connection to version with flat connector) 3NJ41 2 to 3NJ41 4 C 3NJ49 11–2BQ00 1 set 0.949 Auxiliary switch mounting kit (for sizes 1 to 3 with connecting leads) for 3-pole switchable in-line switch disconnectors only 3NJ41 03 3NJ41 2 to 3NJ41 4 A A 3NJ49 13–0AA00 3NJ49 13–1AA01 1 unit 1 unit 0.005 0.019 910 A fuse size NH 3 specially for the protection of transformers with 630 kVA (minimum order quantity 3 units) 3NJ41 8 D 3NJ49 14–8AA00 1 unit 1.340 Mounting hook (one per in-line disconnector required) 3NJ41 2 to 3NJ41 4 A 3NJ49 18–1AA00 1 set 0.120 kg 3NJ59 74–0AB 3NJ49 11–3AA00 6 3NJ49 11–3BA01 3NJ49 11–4AA00 3NJ49 11–1AA00 * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/83 SENTRIC NJ In-Line Fuse Switch Disconnectors Project planning aids ■ Dimension drawings 3NJ41 .1–3, 250 to 630 A single-pole operation 99,5 195 49,8 70 100 9x16 100 410 649 662 6,5 NSE 00925a 55 93 50 17 248 9 B 3NJ41 21 3NJ41 31 3NJ41 41 23 24 25 14 36,5 Panel cutout for flush mounting for 3NJ56 43 140 464 240,5 NSE00248 185 328 169,5 160 185 185 409 775 109 L2,L3 119 43 L3 L1 70 70 200 6/84 24 Siemens LV 30 · 2004 M16x60 59 12 177,5 NSE00247 50 22,5 65 L1 59 110,5 15 185 Ø11 B 52 154 30 Type 3NJ56 43, 1250 A single-pole operation for 185 mm busbar center-to-center distance L2 NSE00242a 15 36,5 160 36,5 185 633 185 L3 18x41 254 300 185 L2 6 121 9x16 L1 8,5 647 3NJ41 03, 160 A 3-pole operation for 100 mm busbar center-to-center distance 185 7 80,5 49 102 198 150 110 NSE00241a 3NJ50 13, 160 A single-pole operation SENTRIC NJ In-Line Fuse Switch Disconnectors Project planning aids 35 NSE00245 185 400 A 100 100 102 Mounting of the in-line fuse switch disconnectors onto busbars for 100 mm busbar center-to-center distance 195 NSE00244a 99,5 OFF position • interlock released • interlock engaged 52 ON position 3NJ41 .3–3, 250 to 630 A 3-pole operation max. 25 B Ø14 A 50 50 50 185 662 649 B Mounting of the in-line fuse switch disconnectors onto busbars for 185 mm busbar center-to-center distance; 100 mm minimum clearance between the conductive parts of all bars NSE00246 3NJ41 23 3NJ41 33 3NJ41 43 23 24 25 335 467 6 185 C 722 Type 15 100 C 52 154 30 50 185 113 35 14x18 max. 36 100 100 3NJ41 51–5DB00 incoming block, 1000 A single-pole operation 3NJ49 12–1DA00 cover (top and bottom) for 185 mm busbar center-to-center distance 99,5 185 100 140 195 NSE00243 220 185 762 665 3NJ49 12-1 DA00" 53 NSE00249 50 44 71 71 Siemens LV 30 · 2004 6/85 SENTRIC NJ In-Line Fuse Switch Disconnectors 4,5 Project planning aids Blanking cover for panel cutout 12 3NJ49 12–2AA00 50 mm wide 49,5 633 NSE00250 Unequipped section covers for busbars 2 NSE00251 3NJ49 12–3BA01 100 mm wide for 185 mm busbars 100 M12 100 370 662 2 6 NSE00252 3NJ49 12–3CA00 50 mm wide for 100 mm busbars 50 M8 410 3NJ49 18–0EA00 3NJ49 18–0DA00 adapter adapter for 60 mm busbar center-to-center for 185 mm busbar center-to-center distance distance 100 27 2 Width of the busbars as required, but minimum clearance of 20 mm to the next busbar or conductive parts 1) Maximum screw-in length: 14 mm, tightening torque: 30 Nm. 6/86 M12 50 25 38 Siemens LV 30 · 2004 34,5 50,5 M8 NSE00253 38 NSE00256 26 13,5 3 100 432 185 NSE00254 60 185 100 100 185 25 3NJ49 11–3AA00 busbar clamp 99,5 185 60 1) 185 M10 NSE00255 M8 185 45 Ø12 406 290 Ø11 100 3NJ59 74–0AB busbar holder 60,5 M8 23,5 25,5 200 100 52 9,5 Plug-In In-Line Switch Disconnectors with Fuses Up to 630 A ■ Overview 3NJ6 plug-in in-line switch disconnectors with fuses are typetested to IEC EN 60947/3 and can be used for voltage levels up to AC 690 V/DC 500 V. The compact design is optimized for switchboards using plug-in technology. The units can be installed horizontally or vertically. All sizes are available in 2-, 3- or 4-pole versions. The front masking frame is automatically interlocked in the ON position. With the front masking frame closed, the degree of protection is IP41. The 3NJ6 plug-in in-line switch disconnectors have a short-circuit strength of up to 100 kA. All device variants can be equipped with solid-state fuse monitoring or a communication function. ■ Benefits Advantages for users and operators • Conversion, upgrading and replacement without deactivating the switchboard • Off-circuit fuse replacement • Free of maintenance • High level of personal safety • Operating handle lockable in the OFF position • Clear switch position indication • Electronic fuse monitoring • Data display via bus systems and Internet through COM function • Modular accessories for retrofitting and expansion • Low power losses and therefore economical operation of the whole switchboard. Advantages for makers of switchgear and controlgear • Modular compact design in a 50 mm grid pattern • Easy and economical assembly thanks to plug-in contact on the incoming side • High packing density in the cubicle • Cable connection with cable clamps or cable lugs • Can be mounted in various depths of control cabinets • Comprehensive range of accessories • Integrated COM function makes additional external equipment unnecessary. ■ Area of application 3NJ6 plug-in in-line switch disconnectors with fuses are ideal wherever distribution boards have a minimum of space but need to accommodate as many cable feeders as possible for power distribution. They can be easily installed in all the industry-standard control cabinets (a depth of at least 400 mm) as well as in the Siemens 8MF/8MC cubicles and in the SIKUS switchboards. They are supplied as prefabricated disconnector panels in the SIVACON switchgear assemblies. The 3NJ6 plug-in in-line switch disconnectors are available for rated continuous currents of 160 A to 630 A. LV HRC fuse links to IEC 60269-1/EN 60269-1 (sizes 00 to 3) take care of overload and short-circuit protection up to AC 690 V/DC 500 V. Typical applications are to be found in industry, power stations, building services, hospitals, hotels, airports and shipbuilding. The 3NJ6 plug-in load isolating switches fulfill all functions safely and reliably: • Power distribution up to AC 690 V and DC 500 V at high shortcircuit strengths • Feeder circuit-breaker and outgoing circuit-breaker in subdistribution boards • Fuse protection of lightning and overvoltage protection devices • Short-circuit and overload protection for frequency converters and soft starters • Internal cost center acquisition 6 ■ Further information Additional and more detailed information is provided in the latest 3NJ6 catalog. The catalog can be downloaded from the Internet as a pdf file at: www.siemens.de/lowvoltage Click on the following links: • Switch disconnectors (power distribution equipment) • 3NJ6 plug-in load isolating switch At the bottom of that page, select the catalog under "Further information". Select 3NJ6, enter data. After clicking on "Next" you can download the catalog onto your PC. Siemens LV 30 · 2004 6/87 SITOR Semiconductor Protection Fuses For semiconductor protection ■ Benefits UL approval was achieved for the 3KL switch disconnectors with fuses in conjunction with the new range of 3NE1 ...–2 fuses. Due to the mechanical stress on the relatively long fuse blades, 3NE41 SITOR fuses should be switchable only occasionally and only at zero current. If it is only permissible to switch at zero current, the switch must be marked accordingly. The use of SITOR fuses rated above 63 A for overload protection is also not permitted when gR fuses (except 3NE1) are used. ■ Area of application When SITOR fuses are used in 3NP, 3KL and 3KM switch disconnectors, a partial reduction of the rated current of the fuse is necessary due to the higher power loss in comparison with LV HRC fuses for line protection. The use of SITOR fuses in switch disconnectors may at times result in current values above the rated currents of the switches. These increased currents occur only when the switch is used with SITOR fuses; they cannot be utilized when the switch is used with standard LV HRC fuses. Details are given in the table below. When SITOR fuses of types 3NC24, 3NC84, 3NE33 and 3NE43 are used, the switching capacity of the switch disconnectors as specified in the catalog must not be fully utilized, as the blades of these fuses (in contrast to LV HRC line-protection fuses) are slotted. Occasional switching of currents up to the rated currents of the fuses is permissible. The operating voltage is limited by the rated voltage of the switch disconnector or the fuses. During current-free switching, the limit value is the rated insulation voltage of the switch disconnector. The 3NE1 “double protection fuses” can be used both as allrange fuses (gR/gS) as well as for semiconductor and lead protection. Due to the dimensions of SITOR fuses, only the fuses shown in the Selection and ordering data below can be used in the 3NP, 3KL and 3KM switch disconnectors. ■ Selection and ordering data For switch disconnectors Type Type 6 SITOR fuse Conductor crossPermissible section required load current Cu of the SITOR fuse in the disconnector1) A Size Operational class mm 2 Rated current Rated voltage A V DT Order No. PS* Weight per PU approx. kg For SENTRIC NP fuse switch disconnectors 3NP35, 3NP50 3NP40 1, 3NP40 7 16 20 25 35 40 50 63 80 1.5 2.5 4 6 000 10 10 16 25 gR/gS gR/gS gR/gS gR/gS 16 20 25 35 690 } } } } 3NE1 813-0 3NE1 814-0 3NE1 815-0 3NE1 803-0 9 units 9 units 9 units 9 units 0.127 0.128 0.127 0.128 gR/gS gR/gS gR/gS gR/gS 40 50 63 80 690 } } } } 3NE1 802-0 3NE1 817-0 3NE1 818-0 3NE1 820-0 9 units 9 units 9 units 9 units 0.127 0.128 0.128 0.129 3NP50 3NP40 7 100 125 125 (105) 2) 35 50 50 00 gR/gS gR/gS gR 100 125 125 690 } } } 3NE1 021-0 3NE1 022-0 3NE1 022-2 3 units 3 units 3 units 0.202 0.202 0.203 3NP52 3NP42 7 160 160 200 200 (190) 2) 250 250 (235) 2) 70 70 95 95 120 120 1 gR/gS gR gR/gS gR gR/gS gR 160 160 200 200 250 250 690 } } } } } } 3NE1 224-0 3NE1 224-2 3NE1 225-0 3NE1 225-2 3NE1 227-0 3NE1 227-2 3 units 3 units 3 units 3 units 3 units 3 units 0.580 0.613 0.582 0.612 0.580 0.626 3NP53 3NP43 7 315 315 2 × 70 2 × 70 2 gR/gS gR 315 315 } } 3NE1 230-0 3NE1 230-2 3 units 3 units 0.581 0.615 3NP53 3NP43 7 350 350 400 2 × 95 2 × 95 2 × 95 2 2 gR/gS gR gR/gS 350 350 400 } } } 3NE1 331-0 3NE1 331-2 3NE1 332-0 3 units 3 units 3 units 0.766 0.754 0.743 3NP54 3NP44 7, 3NP44 76 450 450 (425) 2) 500 (480) 2) 500 (465) 2) 2 × 120 2 × 120 2 × 120 2 × 120 gR/gS gR gR/gS gR 450 450 500 500 } } } } 3NE1 333-0 3NE1 333-2 3NE1 334-0 3NE1 334-2 3 units 3 units 3 units 3 units 0.760 0.768 0.766 0.768 690 1) If a cyclic load is applied, it may be necessary to further reduce the currents (please inquire about precise values). 2) Values in brackets apply to the SENTRIC 3NP4 fuse switch disconnectors. 6/88 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SITOR Semiconductor Protection Fuses For semiconductor protection For switch disconnectors Type Type SITOR fuse Conductor crossPermissible section required load current Cu of the SITOR fuse 1) in the disconnector A Size Operational class mm2 Rated current Rated voltage A V DT Order No. PS* Weight per PU approx. kg For NP fuse switch disconnectors 560 (510)2) 560 (540) 2) 630 (535) 2) 630 (600) 2) 2 × 150 2 × 150 2 × 185 2 × 185 3 gR/gS gR gR/gS gR 560 560 630 630 690 } } } } 3NE1 435-0 3NE1 435-2 3NE1 436-0 3NE1 436-2 1 unit 1 unit 1 unit 1 unit 1.110 1.140 1.110 1.170 3NP44 70, 3NP44 76 710 (600) 2) 690 (570) 2) 710 (685) 2) 2 × (40 × 5) 3 gR/gS gR gR 710 690 710 690 600 600 } C } 3NE1 437-0 3NE1 437-1 3NE1 437-2 1 unit 1 unit 1 unit 1.110 1.120 1.150 3NP44 70 3NP44 76 800 (630) 2) 750 (600) 2) 800 (770) 2) 670 (655) 2) 850 (820) 2) 2 × (50 × 5) 3 gR/gS gR gR gR gR 800 750 800 670 850 690 600 600 690 690 } C } } } 3NE1 438-0 3NE1 438-1 3NE1 438-2 3NE1 447-2 3NE1 448-2 1 unit 1 unit 1 unit 1 unit 1 unit 1.120 1.110 1.180 1.170 1.200 gR/gS 16 20 25 35 690 } } } } 3NE1 813-0 3NE1 814-0 3NE1 815-0 3NE1 803-0 9 units 9 units 9 units 9 units 0.127 0.128 0.127 0.128 gR/gS 40 50 690 } } 3NE1 802-0 3NE1 817-0 9 units 9 units 0.127 0.128 3NP54 3NP44 70, 3NP44 76 3NP54 3NP54 3NP44 76 2 × (40 × 5) 2 × (40 × 8) For SENTRIC 3KL5, 3KL6 and 3KM5 switch disconnectors with fuses 3KL50 30 3KM50 30 16 20 25 35 1.5 2.5 4 6 40 50 10 10 0003) 63 16 63 } 3NE1 818-0 9 units 0.128 3KL52 30 3KM52 30 80 25 80 } 3NE1 820-0 9 units 0.129 3KL52 30 3KM52 30 100 125 125 35 50 50 00 gR/gS gR/gS gR 100 125 125 690 } } } 3NE1 021–0 3NE1 022–0 3NE1 022–2 3 units 3 units 3 units 0.202 0.202 0.203 3KL55 30 3KM55 30 160 160 200 200 250 245 70 1 gR/gS gR gR/gS gR gR/gS gR 160 160 200 200 250 250 690 } } } } } } 3NE1 224-0 3NE1 224-2 3NE1 225-0 3NE1 225-2 3NE1 227-0 3NE1 227-2 3 units 3 units 3 units 3 units 3 units 3 units 0.580 0.613 0.582 0.612 0.580 0.626 gR/gS gR 315 315 } } 3NE1 230-0 3NE1 230-2 3 units 3 units 0.581 0.615 gR/gS gR gR/gS 350 350 400 } } } 3NE1 331-0 3NE1 331-2 3NE1 332-0 3 units 3 units 3 units 0.766 0.754 0.743 gR/gS gR gR/gS gR 450 450 500 500 } } } } 3NE1 333-0 3NE1 333-2 3NE1 334-0 3NE1 334-2 3 units 3 units 3 units 3 units 0.760 0.768 0.766 0.768 3 gR/gS gR gR/gS gR 560 560 630 630 690 } } } } 3NE1 435-0 3NE1 435-2 3NE1 436-0 3NE1 436-2 1 unit 1 unit 1 unit 1 unit 1.110 1.140 1.110 1.170 3 gR/gS gR gR 710 710 690 600 690 } C } 3NE1 437-0 3NE1 437-1 3NE1 437-2 1 unit 1 unit 1 unit 1.110 1.120 1.150 690 600 690 690 690 } C } } } 3NE1 438-0 3NE1 438-1 3NE1 438-2 3NE1 447-2 3NE1 448-2 1 unit 1 unit 1 unit 1 unit 1 unit 1.120 1.110 1.180 1.170 1.200 95 120 3KL57 30 3KM57 30 315 280 2 × 70 3KL57, 3KL61 30 3KM57 30 350 (330) 3) 350 (300) 3) 400 (375) 2 × 95 3KL61 30 3KM57 30 450 (400) 3) 450 (325) 3) 500 (400) 3) 500 (350) 3) 2 × 120 3KL61 30, 3KL62 – 560 560 630 615 (630)4) 2 × 150 710 710 (700)4) 630 2 × (40 × 5) 800 770 (800)4) 630 (760)4) 630 (670)4) 630 (790)4) 2 × (50 × 5) 3KL61 30, 3KL62 3KL61 30, 3KL62 – – 2 2 × 185 3 2 × (40 × 5) 2 × (40 × 8) gR/gS gR gR gR gR 800 800 670 850 690 1) If a cyclic load is applied, it may be necessary to further reduce the currents (please inquire about precise values). 2) Values in brackets apply to the 3NP4 fuse switch disconnectors. 3) Values in brackets apply to the 3KL5/3KM5 switch disconnectors. 4) Values in brackets apply to the 3KL62 switch disconnectors. Nameplate contains standard values acc. to IEC/EN 60947-3. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/89 6 SITOR Semiconductor Protection Fuses For semiconductor protection For switch disconnectors SITOR fuse Conductor cross-secPermissible tion required load current Cu of the SITOR fuse 1) in the disconnector Type A Size Operational class mm 2 Rated current Rated voltage2) A V DT Order No. PS* Weight per PU approx. kg For SENTRIC NP fuse switch disconnectors gR 25 35 50 63 690 } } } } 3NE8 015–1 3NE8 003–1 3NE8 017–1 3NE8 018–1 1 unit 1 unit 1 unit 1 unit 0.205 0.204 0.203 0.205 aR 80 100 125 160 690 } } } } 3NE8 020–1 3NE8 021–1 3NE8 022–1 3NE8 024–1 1 unit 1 unit 1 unit 1 unit 0.203 0.205 0.213 0.207 gR 32 40 50 63 1000 } } } } 3NE4 101 3NE4 102 3NE4 117 3NE4 118 1 unit 1 unit 1 unit 1 unit 0.278 0.277 0.276 0.279 aR 80 100 125 160 1000 } } } } 3NE4 120 3NE4 121 3NE4 122 3NE4 124 1 unit 1 unit 1 unit 1 unit 0.276 0.278 0.279 0.279 aR 100 125 160 200 250 1000 } } } } } 3NE3 221 3NE3 222 3NE3 224 3NE3 225 3NE3 227 1 unit 1 unit 1 unit 1 unit 1 unit 0.580 0.568 0.573 0.570 0.580 aR 315 350 400 450 1000 } } } } 3NE3 230–0B 3NE3 231 3NE3 232–0B 3NE3 233 1 unit 1 unit 1 unit 1 unit 0.585 0.590 0.576 0.720 aR 400 450 500 560 1000 } } } } 3NE3 332–0B 3NE3 333 3NE3 334–0B 3NE3 335 1 unit 1 unit 1 unit 1 unit 0.759 0.748 0.753 0.756 2 × 185 2 × 200 2 × 200 2 × (50 × 5) aR 630 710 800 900 1000 900 800 690 } } } B 3NE3 336 3NE3 337–8 3NE3 338–8 3NE3 340–8 1 unit 1 unit 1 unit 1 unit 0.760 0.762 0.764 0.753 205, 210 (235) 260, 270 (280) 375, 400 (390) 120 240 2 × (30 × 5) aR 250 315 450 800 } } } 3NE4 327–0B 3NE4 330–0B 3NE4 333–0B 1 unit 1 unit 1 unit 0.753 0.760 0.760 3NP44 7, 3NP54 (3NP44 76) 410, 450 (415) 540, 600 (480) 2 × (30 × 5) 2 × (40 × 5) aR 500 710 800 } } 3NE4 334–0B 3NE4 337 1 unit 1 unit 0.754 0.761 3NP44 7, 3NP54 (3NP44 76) 140, 145 (140) 175, 180 (175) 220, 225 (215) 70 95 120 gR 150 200 250 500 } } } 3NC2 423–3 3NC2 425–3 3NC2 427–3 3 units 3 units 3 units 1.060 1.050 1.060 250, 255 (245) 320, 330 (315) 370, 400 (360) 185 240 240 gR 300 350 400 500 } } } 3NC2 428–3 3NC2 431–3 3NC2 432–3 3 units 3 units 3 units 1.070 1.050 1.060 120, 135 (120) 160, 180 (155) 200, 225 (195) 270, 300 (260) 385, 425 (375) 630, 800 (630) 70 95 120 240 2 × 150 3 × (60 × 6) gR 150 200 250 350 500 1000 660 } } } } } C 3NC8 423–3 3NC8 425–3 3NC8 427–3 3NC8 431–3 3NC8 434–3 3NC8 444–3 3 units 3 units 3 units 3 units 3 units 1 unit 1.060 1.060 1.060 1.070 1.060 1.080 3NP40 7, 3NP50 (3NP40 75/3NP40 76) 25 33 45 54 (53) 4 6 10 16 68 89 (85) 106 (100) 130 (125) 25 35 50 70 32 38, 40 45, 50 59, 63 6 10 10 16 76, 80 90, 95 115, 120 144, 150 25 35 50 70 3NP43, 3NP53 (3NP43 76) 100 (100) 120 (125) 150 (160) 190 (200) 230 (250) 35 50 70 95 120 3NP43 7, 3NP53 (3NP43 76) 270, 285 (285) 290, 310 (310) 310, 330 (330) 330, 360 (360) 185 240 240 2 × 150 3NP44 7, 3NP54 (3NP44 76) 345 (340) 385 (370) 430, 450 (410) 490, 510 (450) 240 2 × 150 2 × 150 2 × 185 560, 580 (500) 590, 630 (510) 605, 630 (520) 630, 630 (530) 3NP44 7, 3NP53 (3NP44 76) 3NP42, 3NP52 6 00 03) 1 2 3 aR 600 1) If a cyclic load is applied, it may be necessary to further reduce the currents (please inquire about precise values). 2) If overvoltage category 2 (instead of 3) and pollution degree 2 (instead of 3) in accordance with EN 60947-1 is maintained, the rated insulation voltage of the SENTRIC 3NP switch disconnectors also amounts to Ui = 1000 V. 3) Due to the mechanical stress on the relatively long fuse blades, 3NE41 SITOR fuses should be switchable only occasionally and only at zero current. 6/90 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered. SITOR Semiconductor Protection Fuses For semiconductor protection For switch disconnectors Type Type SITOR fuse Conductor cross-secPermissible tion required load current Cu of the SITOR fuse 1) in the disconnector A Size Operational class mm 2 Rated current Rated voltage A V DT Order No. PS* Weight per PU approx. kg For 3KL5, 3KL6 and 3KM5 switch disconnectors with fuses 3KL50 3KM50 25 33 45 54 4 6 10 16 3KL52 3KM52 68 89 105 130 25 35 50 70 3KL55 3KM55 32 40 50 63 6 10 10 16 80 95 120 150 25 35 50 70 00 0 25 35 50 63 690 } } } } 3NE8 015–1 3NE8 003–1 3NE8 017–1 3NE8 018–1 1 unit 1 unit 1 unit 1 unit 0.205 0.204 0.203 0.205 aR 80 100 125 160 690 } } } } 3NE8 020–1 3NE8 021–1 3NE8 022–1 3NE8 024–1 1 unit 1 unit 1 unit 1 unit 0.203 0.205 0.213 0.207 gR 32 40 50 63 1000 } } } } 3NE4 101 3NE4 102 3NE4 117 3NE4 118 1 unit 1 unit 1 unit 1 unit 0.278 0.277 0.276 0.279 aR 80 100 125 160 1000 } } } } 3NE4 120 3NE4 121 3NE4 122 3NE4 124 1 unit 1 unit 1 unit 1 unit 0.276 0.278 0.279 0.279 aR 100 125 160 200 250 1000 } } } } } 3NE3 221 3NE3 222 3NE3 224 3NE3 225 3NE3 227 1 unit 1 unit 1 unit 1 unit 1 unit 0.580 0.568 0.573 0.570 0.580 aR 315 350 400 450 1000 } } } } 3NE3 230–0B 3NE3 231 3NE3 232–0B 3NE3 233 1 unit 1 unit 1 unit 1 unit 0.585 0.590 0.576 0.720 aR 400 450 500 560 1000 } } } } 3NE3 332–0B 3NE3 333 3NE3 334–0B 3NE3 335 1 unit 1 unit 1 unit 1 unit 0.759 0.748 0.753 0.756 3KL55 3KM55 90 110 140 175 210 35 50 70 95 120 3KL57 3KM57 240 265 290 320 185 240 240 2 × 150 3KL61, 3KL62 3KM57 340, (360)3) (290)2) 380, (400)3) (320)2) 440, (470)3) (360)2) 500, (530)3) (400)2) 240 2 × 150 2 × 150 2 × 185 540, (580)3) (400)2) 600, (640)3) (400)2) 630, (720)3) (400)2) 630, (800)3) (460)2) 2 × 185 2 × 200 2 × 200 2 × (50 × 5) aR 630 710 800 900 1000 900 800 690 } } } B 3NE3 336 3NE3 337–8 3NE3 338–8 3NE3 340–8 1 unit 1 unit 1 unit 1 unit 0.760 0.762 0.764 0.753 200, (200)3) (175)2) 260, (260)3) (230)2) 370, (370)3) (340)2) 425, (450)3) (380)2) 600, (630)3) (400)2) 120 240 240 or 40 × 8 2 × (30 × 5) 2 × (40 × 5) aR 250 315 450 500 710 800 } } } } } 3NE4 327–0B 3NE4 330–0B 3NE4 333–0B 3NE4 334–0B 3NE4 337 1 unit 1 unit 1 unit 1 unit 1 unit 0.753 0.760 0.760 0.754 0.761 145 180 225 70 95 120 gR 150 200 250 500 } } } 3NC2 423–3 3NC2 425–3 3NC2 427–3 3 units 3 units 3 units 1.060 1.050 1.060 255 330 400 185 240 240 gR 300 350 400 500 } } } 3NC2 428–3 3NC2 431–3 3NC2 432–3 3 units 3 units 3 units 1.070 1.050 1.060 135 180 225 300 425 800 (630) 70 95 120 240 2 × 150 2 × (60 × 6) gR 150 200 250 350 500 1000 660 } } } } } C 3NC8 423–3 3NC8 425–3 3NC8 427–3 3NC8 431–3 3NC8 434–3 3NC8 444–3 3 units 3 units 3 units 3 units 3 units 1 unit 1.060 1.060 1.060 1.070 1.060 1.080 3KL61, 3KL62 3KL61, 3KL62 1 gR 2 3 1) If a cyclic load is applied, it may be necessary to further reduce the currents (please inquire about precise values). aR 800 800 600 3) Values in brackets apply to the 3KL62 switch disconnectors. Nameplate contains standard values acc. to IEC/EN 60947-3. 2) Values in brackets apply to the 3KM switch disconnectors. ■ Further information Please inquire about further combination possibilities. For further information about fuses, see SITOR Configuration catalog, Order No.: E20001-A700-P302-X-7600. * This quantity or a multiple thereof can be ordered. Siemens LV 30 · 2004 6/91 6 SITOR Semiconductor Protection Fuses Notes 6 6/92 Siemens LV 30 · 2004
Similar documents
Siemens Fuse Switch Disconnectors
Main control and EMERGENCY-STOP switches with base mounting and door-coupling rotary operating mechanism 1) 3) • With 300 mm switch shaft • Lockable in 0 position with up to 3 padlocks • Degree of ...
More information