DAITSU
Transcription
DAITSU
DAITSU Split Type Air Conditioner ENGINEERING DATA Models: H2SM-18RA03/R1(B) Content 1.Description of product model coding and series introduction.......... 1 2.Specifications .........................................................................................4 3.Curves of performance ..........................................................................6 4.Description,dimension and function of main components and accessories ....................................................................................9 5.Knock-down drawings ..........................................................................16 6.Brief introduction to electrical contreol functions .............................22 7.Circuit diagram & wiring diagram.........................................................29 8.Abnormity diagnose ..............................................................................34 9.Trouble shooting ...................................................................................37 10. Refrigerating cycle diagram ...............................................................39 11.Noise level test chart and air velocity distribution ...........................41 12.Installation and accessory parts ........................................................44 No.001054 Description of product model coding and series introduction 1 Description of product model coding and series introduction Introductory Remarks A. Description of coding rules of unit model Coding rules and descriptions are as follows: 2 1 2 3 4 6 5 7 8 9 10 11 Inverter type:(B) Refrigerant type:R1(R407C),R2(R410A) Applicable voltage:3(220~230V),4(240V) Applicable frequency:0(50HZ),1(60HZ) Developing sequence :A,B,C,D... C/L-cooling only Function code R/H-heat pump E-electric aided heating Nominal cooling capacity (BTU/h)with the first two numbers based on thousand unit The structure code of indoor & outdoor unit: S (wall-mounted),W (window type),P (cabinet type) One by two type H-Abbreviation of Haier Examples: H2SM-18RA03/R1(B),It represents inverter wall-mounted multi-type split type room air conditioner.The cooling capacity is 18000BTU/h,and the power supply is 220-230V/50Hz,”A” means the improvement B.Standard Situation/Conditions No. Operating condition indoor air status DB C WBOC outdoor air status DB C WBOC 1 Norminal cooling 27OC 19OC 35OC 24OC 2 Norminal heating 20OC 15OC 7OC 6OC 3 Norminal electrical heating --- --- --- --- O 2 O Description of product model coding and series introduction C.Series brief introduction 1.comfortable:wide-angle airflow The vertical dual-flap and horizontal wide-angle louvers ensure the cool(warm air reaches every corner of the room. 2.Health air purifying and negative ion function An air purifying filter with deodorizing and disinfecting functions keeps the air clean and users healthy.The negative ion generator can produce the negative ion that make the air fresher and cleaner. 3.Quiet operation Fan With Random-pitched Blades. Random-pitched blades help reduce operating noise while maintaining a high airflow rate. 2.Engergy efficient The design of inner-grooved copper tube greatly increases the refrigerant contact area and the efficiency of cooling/heating functions. 5.Convenience Auto restart and washable panel: The grille can be removed easily and washed when necessary.Any series have the function then even if the power falls when the unit is operating unit will automatically return to the operating settings in use before the power failure when power is restored. 6.Wide variety of functions 24-Hour Timer: 24-hour timer allows users to select the exact time they would like the air conditioner to turn on and to turn off.Timers on previous models operation based on the number of hours of desired operation. 7.Night-set models When the air conditioner is operationg on the timer-off circuit.The preset room temperature gradually rises(going down in heating)before the unit stops as shown delow.Users can sleep comfortably without sudden change in temperature. 8.Program”dry” This function automatically reduces the level of humidity while maintaining the preset indoor temperature. 3 Specifications 4 Specifications Model: H2SM-18RA03/R1(B) Single Cooling capacity(W) Cooling coefficient(W/W) Cooling power input(W) Double 5000 3350 (500-3800) (700-6000) 2.17 2.23 1500 2300 (300-1600) (320-2500) 1.5X10-3 Moiture removal(m3/h) Operating voltage range(V) 220-230 ~ Operating temp. range ( C) -7-43 O Single Heating capacity(W) 4200 (600-5200) 6600 (700-8000) Heating coefficient(W/W) 2.10 2000 (300-2000) 2.40 2500 (320-3000) Heating power input(W) Frequency range(Hz) Refrigerant type Variation of temp. adjust ( C) +1 Air sending angle indoor unit Fan type outdoor unit Climate type: T1 Class of electric shock O Double 50 R407C 60 O Cross flow fan Axial flow fan I Indoor unit noise( dB(A) ) (cooling) 41/37/31 Outdoor unit noise( dB(A) ) (cooling) 54/51/48 Indoor unit noise ( dB(A) ) (heating) 40/36/31 Outdoor unit noise( dB(A) ) (heating) 54/51/48 Net dimensions ( mm) (indoor unit) Packaging dimensions ( mm) (indoor unit) Net/gross weight (kg) (indoor unit) Max. mounting height difference (m) Refrigerant charge(g) (R407C) Frequency of filter cleaning Compressor model Compressor oil charge (cc) Maxi. length of connecting pipe (m) Cap. tube type muffle model: Fan speed(H/M/L)(r/min) cool (indoor unit) heat Fan speed(r/min) (outdoor unit) 760 x182x285 822x267x297 8.5/10.6 Net dimensions ( mm) (outdoor unit) Packaging dimensions ( mm) (outdoor unit) Net/gross weight (kg) (outdoor unit) 810X288X680 949X406X745 56/61 1600 indoor unit outdoor unit Current entering side (indoor/outdoor) Once/2 weeks Max. refrigerant charge (g) 1610 C-7RB237H03AA Compressor manufacturer SANYO Compressor protector type length(mm) drain hose diametre(mm) Internal 2000 16 Piling layers 5 600 15(single)/20(double) electronic expansion valve 1300/1110/920 1300/1110/920 860/780/560 Cut-off vavle(inch) two-way three-way 1/4 1/2 Max. operating pressure at warm side(Mpa) 2.65 Type of tube of evaporator and condenser Size of tube of evaporator and condenser(mm) Appearance features of indoor unit Appearance features of outdoor unit Max. operating pressure at cool side(Mpa) 5 8 4 indoor Internal thread O7/O9.52 plastic iron 2.65 Curves of performance 6 Curves of performance Curves of cooling capacity and heating capacity as a function of outdoor temperature(-7OC~43OC) 15 20 25 15 20 25 7 8 Description,dimension and function of main components and accessories 9 Description,dimension and function of main components and accessories Net dimension of indoor unit and outdoor unit Indoor unit 760 250 182 295 680 583 815 319.5 352 869 10 Description,dimension and function of main components and accessories 11 12 2 -7 /-8 (INVERTER) 13 14 15 Knock-down drawings 16 Model: H2SM-18RA03/R1(B) 1 Exploded View 17 18 2 PARTS LIST MODEL: No. in exploded view. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 H2SM-18RA03/R1(B) INDOOR UNIT Name of part Specialized code Drain hose Air purifying Remote controller Guarding ring Battery Screw assembly Inlet grille Decorate panel Air filter Front panel Display panel fixation 1 Display panel fixation 2 Display panel Evaporator assy. Bearing Cross flow fan Negative ion generator Drain pan assy. Wiring clip Piping support Stepping motor Electric box cover I Electric box cover II Cover for fan motor Louver 1 Louver 2 Frame assy. Fan motor Fix board Mounting plate PCB Electric box Terminal block 001A1434039 0010805043 0010403015 001A1433307 001A4600001 0010600115 0010202789D 0010203390 0010201841 0010202788 0010202643 0010201857 0010802894 0010703018 0010801543 0010202133 0010401985 0010802911 0010201995 0010201858 0010401869 0010201852 0010201853 0010201860 0010202791 0010202792 0010802568 0010401823 0010202793 0010101274 0010402946 0010201851 0010402607 19 QTY. 1 1 1 1 2 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 remark indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit indoor unit MODEL: NO. In exploded view 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 H2SM-18RA03/R1(B) OUTDOOR UNIT Name of part Front guard Handle Left Side panel Upper panel Front panel Axial fan Motor Motor support Right Side panel Stop valve Heat exchanger Rear guard 4-way valve Stop valve support Capacitor clamp 2 Capacitor clamp 1 Bottom panel assy. Compressor PCB(power controller) ———— Terminal block 22 23 24 Separator plate assy. Electrical box Damping plaster 25 Coil for electronic expansion valve 26 27 28 29 30 31 32 33 34 35 36 37 38 Reactor Power model BRIDGE DIODE PCB(main controller) Fuse250v Return gas sensor Temperature sensor of compressor Evaporator sensor 4-way valve winding Rubber mat Stop valve AB temp. sensor Defrost. temp. Sensor 20 Part specialized code 001A1303126A 001A1436182 001A1101039 0010100471 001A1101038 001A2331024 001A3000076 001A1301133 001A1101041A 0010701920 001A0400039 001A1303128 0010700029 001A1301127A 001A1431404 001A1431403 001A0100237 0010702259 0010401975 ———— 001A4000112 001A4000113 001A4000114 0010800009 001A1431400 001A1755124 001A2500058 001A2500059 001A3800042 0010400475 001A3700015 0010402930 001A4100013 001A3900062 001A3900074 001A3900063 001A2500053 001A1752769 0010701919 001A3900060 001A3900061 QTY. 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 2 1 1 1 —— 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 4 2 1 1 remark OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT Brief introduction to electrical control functions 22 7. INTRODUCTION OF ELECTRIC CONTROL FUNCTION Including brief introduction of items of inverter 2 by 1 series air conditioner and electric control function H2SM-18RA03/R1(B) 7.1 Corresponding operation mode of EMERGENCY SWITCH If the time of pressing the switch is less than 5 seconds, it should be EMERGENCY OPERATION; if over 5 seconds but less than 10 seconds, should be TEST RUN. If the time is over 10 seconds but less than 15 seconds, it is the PREVIOUS TROUBLE DISPLAY (also called TROUBLE RECORD). When TEST RUN, EMERGENCY OPERATION, TROUBLE RECORD are displayed, they can be stopped by using remote control or pressing the switch again. During remote control, press this switch to stop. When powered on, even if pressing this switch continuously, the remote signals can also be received. When stopped, if pressing this switch, the maximum time can not receive remote signals is 15 seconds. 15 seconds later, it can receive the remote signals. EMERGENCY OPERATION: When the time of pressing the switch is less than 5 seconds, the buzzer will sound once when pressing, the power indicator light will light up. After releasing the switch, the unit starts EMERGENCY OPERATION. When the EMERGENCY OPERATION starts, the indoor heat sensitive resistor does not reach 23℃ (over 25.7K), the unit starts HEATING operation; when temperature reaches 26.6℃ (21.3K), the sensor is OFF; when the heat sensitive resistor is over 23℃ (under 25.3K), the unit starts COOLING operation, the set temperature is 26℃ (22K), airflow is AUTO. TEST RUN: When the time of pressing the switch is over 5 seconds, the buzzer will sound twice, release the switch, the unit will start TEST RUN. When the time reaches 10 seconds, the TEST RUN is cancelled, and the unit starts TROUBLE RECORD display. The airflow is “HIGH”, the unit starts COOLING operation, 30 minutes later it stops. TROUBLE RECORD DISPLAY mode: When the time of pressing the switch is over 10 seconds, the buzzer will sound 3 times, after releasing the switch, the unit starts TROUBLE RECORD DISPLAY mode. When the time reaches 15 seconds, the power indicator light will go out, and the TROUBLE RECORD DISPLAY mode is cancelled. The previous alarm contents are displayed by the lighting up, flash, going out of the power indicator light, timer indicator light and operation indicator light. 30 seconds later, the TROUBLE RECORD DISPLAY mode is deleted. During the display, all the other remote signals can not be received except for stop signal. When there is no trouble, there will be no display, only the buzzer sounds. 23 1. Ab n o r m i t y d i a g n o s e For the appeared abnormal phenomena, please refer to the following table for trouble analysis and troubleshooting: List of error code: Error display Abnormity mode Indoor Outdoo r Automati c restore Possible reason Running Heat Cool Abnormity of indoor thermistor ★ ■ ■ * * 1. Inserter does not contact well or control board is not good. Abnormity of thermal conversion thermistor ★ □ □ * * 1. Inserter does not contact well or control board is not good. Abnormity of defrosting thermistor □ □ ★ * * 1. Inserter does not contact well or control board is not good. Abnormity discharging thermistor ★ □ ■ * * 1. Inserter does not contact well or control board is not good. Abnormity of control board thermistor □ ■ ★ * * 1. Inserter does not contact well or control board is not good. Abnormity of module thermistor □ ★ □ * * 1. Inserter does not contact well or control board is not good. Abnormity of outdoor thermistor □ ★ ■ * * 1. Inserter does not contact well or control board is not good. of * Transmission abnormity ■ Compressor running abnormity ★ ■ □ * Overhigh discharging temperature protection ■ ★ ■ * ■ ★ * 1. There is great interference source around 2. Incorrect wire connection or control board is not good. 1. Check if compressor shaft is seized. 2. Whether power module is damaged 1. Whether system gas is insufficient or charged gas is too much. 2. Whether system voltage is too high (above242V) or too low (below 187V) 3. Whether capillary tube is blocked. 4. Whether sensors or control board components are abnormal. 5. Whether the indoor/outdoor ambient temperature is too high. 1. AC protection current ★ ★ ■ * 2. 3. 24 Whether system is charged too many gases. Whether voltage is too low (below 187V). Whether CT or control board component is abnormal. 1. DC protection current Insufficient protection current 2. ★ ★ □ * 3. Outdoor control board temperature protection ■ ■ ★ ★ □ * ★ * 1. 2. Whether voltage is too low. Whether control board damaged. 1. Whether control board is abnormal. Whether outdoor ambient temperature is too high. 2. 1. 2. Module temperature rising protection □ ★ ★ * 3. 4. 1. 2. 3. High-load protection ★ ★ ★ * 4. 5. 1. CT wiring disconnected protection ★ ■ ★ * 2. 3. * EEPROM abnormity ★ □ □: Lightening ★: Flashing ■: Blackout is Whether compressor shaft is seized. Whether power module is damaged. Whether heat emission glue is evenly distributed. Whether system voltage is too high (above242V) or too low (below 187V) Whether filter is blocked. Whether the indoor/outdoor ambient temperature is too high Whether system is charged too much gases. Whether control board component is damaged. Whether voltage is too high or too low. Whether control board is damaged. Whether 4-way valve is converted. Whether charged gas is normal 1. Whether control damaged. board is 2. Whether control damaged. board is ★ * Note: Whether compressor shaft is seized. Whether power module is damaged. Whether system voltage is too high (above242V) or too low (below 187V) * Indicating that this function is provided. 7.2 DEFROSTING OPERATION (1) The condition of starting defrosting After HEATING operation start, or after the previous defrosting operation has finished about 40 minutes, and the thermostat is at ON state during HEATING operation, the defrosting heat sensitive resistor is less than 4.2℃ and has checked for over 2 minutes. (2) The condition of canceling defrosting The defrosting heat sensitive resistor is over 15℃, or 9 minutes 15 seconds after 25 defrosting start (3) Defrosting process When defrosting starts, the defrosting signal is sent to indoor unit, the outdoor fan motor and compressor stop, simultaneously, the electronic expansion valve are totally open. 45 seconds later, 4-way valve is OFF, the compressor operates in 50Hz speed. 30 seconds later, the compressor operates in 120Hz speed. It is forbidden to cancel defrosting operation unless 75 seconds have elapsed after the defrosting start. However, in rated operation, the compress operates in rated frequency. 9 minutes 15 seconds after the defrosting operation start, or when the defrosting heat sensitive resistor detects it is over the temperature of canceling defrosting to cancel defrosting operation. After it meets the condition to finish defrosting, the compressor stops, the electronic expansion valve is at pre-defrosting standard open degree. 45 later, if the thermostat is ON, the outdoor fan motor operates in LO, 2 seconds later, the 4-way valve is ON, after operating in 58Hz for 30 seconds, the compressor will operate in specified frequency. DEFROSTING FLOW CHART 2 分 2 min 压缩机 Compressor 四通阀 4-way valve 室外风机 Outdoor fan motor Outdoor fan Defrosting process 4-way valve Defrosting process Compressor 55S 5S Defrosting process 55S 60S Defrosting finish compressor restart 7.3 Control of 4-way valve (HI refers to the 4-way valve is open, LO refers to the 4-way valve is stopped) When HEATING HI, in 3-minute waiting, 2 minutes 50 seconds HI, the rest 10 seconds LO When DEHUMIDIFYING LO When HEATING (after COOLING & DEHUMIDIFYING 3-minute waiting is finished) HI, after 3-minute stop still is HI When transferring to COOLING & DEHUMIDIFYING from HEATING, 3 minutes later is LO When transferring to HEATING from COOLING & DEHUMIDIFYING, 3 minutes later is HI In HEATING, when the thermostat is OFF, it still is HI; in DEFROSTING, perform DEFROSTING control 制热 HEATING 制冷除湿 COOLING & DEHUMIDIFYING 停止 STOP 压机 COMPRESSOR ON 四通阀 4-WAY VALVE ON 3 分待机 3-minute waiting 3 分 3min 2 分 50 秒 2min 50s 26 7.4 Control of indoor unit air sending Heat start control (excluding defrosting, thermostat is ON): 1) For the first operation or after defrosting, when HEATING starts but fan motor does not start to run, thermostat is ON, heat exchanging heat sensitive resistor is over 25℃, the fan motor starts in weak wind; when under 25℃, the fan motor stops, until reaching to over 25℃. In fan motor operating state, start with weak wind. 2) When detecting over 35℃, or the fan motor has started operating for 4 minutes, it will run as set fan speed, (4 minutes is counted after 3-minute waiting, thermostat is ON and fan motor starts rotating). 3) When operating in set fan speed, if the temperature does not reach 25℃, it is weak wind. 设定风速 SET FAN SPEED 弱风 WEAK WIND 4 分钟 4min 7.5 Indoor unit mode output selection: PIN36 PIN37 (1-the down-lead of this chip is connected with high level; 0- the down-lead of this chip is connected with low level) PIN37 PIN36 The down-lead of corresponding chip 1 1 Indoor unit is 25 series (actually called 32 series) 0 1 Indoor unit is 36 series or 40 series 1 0 Indoor unit is 50 inverter packaged type indoor unit 0 0 Indoor unit is 71 packaged type indoor unit 7.6 Operation mode Divided into COOLING, DEHUMIDIFYING, HEATING three operation modes COOLING & DEHUMIDIFYING OPERATION: According to the difference between the remote setting and the temperature set to determine the condition of indoor unit operation frequency section, E= indoor temperature – temperature set According to the value of temperature difference to determine the frequency section of indoor unit and sent to outdoor unit, by which to determine the operation frequency of outdoor unit There is 1℃ deviation compensation. Simultaneously, the thermostat ON once, and can not be OFF within 6 minutes HEATING OPERATION: According to the difference between the remote setting and the temperature set to determine the condition of indoor unit operation frequency section, E= indoor temperature – temperature set According to the value of temperature difference to determine the frequency section of indoor unit and sent to outdoor unit, by which to determine the operation frequency of outdoor unit There is 1℃ deviation compensation. Simultaneously, the thermostat ON once, and can not be OFF within 6 minutes In COOLING & DEHUMIDIFYING, the heat exchanging heat sensitive resistor is under 2 ℃ (1BH), the displayed section is 1; after 3 minutes, if the heat sensitive resistor is over 4℃ (1EH), it resumes to normal control; within 30 minutes after resuming to normal 27 control, the maximum displayed section is 3. When the displayed section is 1, the heat exchanging heat sensitive resistor will be under 0℃ (18H) for about 1 minute, the thermostat is OFF, the unit will be in 3-minute waiting state, then when the heat exchanging heat sensitive resistor is over 2℃ (1BH), section 1 will resume. 7.7 Low load protection control When the heat exchanging heat sensitive resistor is abnormal, this protection should be cancelled. 热敏电阻 Heat sensitive resistor 设定区段 Set section 区段 3 Section 3 区段 1Section 1 1 分 1min 3 分待机 3-minute waiting 3 分以上 Over 3min 30 分钟内 Within 30min Thermal conversion temperature: 2ºC -0.5ºC Display frequency A B Normal Normal Normal Limit Min. frequency Min. frequency Stop Min. Stop Limit Normal Min Limit 7.8 Control of outdoor fan speed 2 seconds before compressor starts, start in LO 20 seconds after compressor stops, OFF When it is over 40Hz, operation mode, number of sets in operation and the temperature of condenser determine the fan speed. In COOLING operation and the over 40Hz single set operates, if the temperature of condenser is less than 35℃, the fan speed will be LO; if it is over 43℃, fan speed is HI (98.8.31). According the number of operation frequency the fan speed will switch between HI (HEATING) and ME (COOLING & DEHUMIDIFYING). When two units are in COOLING operation: if in LO speed, the temperature of sensor to determine outdoor defrosting ≥ 43℃, the outdoor fan motor will be in HI speed. If the temperature of sensor to determine outdoor defrosting < 35℃, the outdoor fan motor will be in LO speed. For two units in COOLING operation, if one of the two indoor units is packaged type, the outdoor unit will be HI, LO speed; if neither of them are packaged type, the outdoor unit will be ME, LO When single outdoor unit is in COOLING operation, it is ME, LO speed When single outdoor unit is in HEATING operation, it is ME, LO speed When two outdoor units are in HEATING operation, they are HI, LO speed 28 Circuit diagram & wiring diagram 29 Circuit diagram outdoor unit H2SM-18RA03/R1(B) 30 Circuit diagram indoor unit R25 +5 CN3 R18 10K R22 +12 R15 R19 33K 10K 1K C27 102 Q3 9013 远程通信 CN11 FUSE C11 T3.15A 0.1uF/275V C10 1 1N4007 IC7 1N4007 2 ZE1 CN15 10K Q2 9013 D4 1N4007 BT1 4 220VL R17 D2 0.1uF/275V LX 1 D5 S14K350 D3 D1 20mH 1N4007 1N4007 C12 104 C1 2200U/25V +5 3 Vout C3 C14 104 220U/16V 7805 2 3 1 Vin GND 27 1 2 1 220VN +5 +5 R8 10k R47 10k Q1 10K BP1 R16 R11 4.7K 1K 9013 +5 磁保护开关 Q5 9013 Q9 9013 +5 CN12 10k R43 2.2K IC4 C16 103 室内外通信 R39 R45 2.2K 220V-N R46 TLP521 R44 D7 6 5 4 1N4007 D6 CN16 1 1N4007 10K C15 102 TLP371 1 2 +5 1 2 3 4 330 ¼¯ÖпØÖƽÓÊÕ ¼¯ÖпØÖÆÊä³ö R40 10K ·ç»ú·´À¡ ÊÒÍâͨÐŽÓÊÕ R29 51K C30 102 C31 102 C32 103 CON3 ÊÒÍâͨÐÅ·¢ËÍ 1K Ò£¿Ø½ÓÊÕR27 R28 1K 1 2 3 TXD RXD ·çËÙ·´À¡ PGÊä³ö ¸ºÀë×Ó C9 100u/16v C6 PG输出 +12V IC6 R20 10K C24 104/50V ×ÏÍâÏß ´Å±£»¤¿ª¹Ø A B C D 2UF 450V TLP3526 内风机 R21 680 R7 4.7K 0.01U*120/300V R41 27 SDA A B C R30 22K 220V-N CN14 10K AB32 PTC5 PTC3 PTC2/MCLK PTC1 PTC0 OSC1 OSC2 CGMXFC VSSA VDDA VREFH PTD7 PTD6/TACLK PTD5 PTD4/TBCLK PTH1/KBD4 PTH0/KBD3 PTD3 PTD2 AVSS/VREFL VDDAREF PTD1 PTD0 ATB7/ATD7 ATB6/ATD6 ATB5/ATD5 ATB4/ATD4 ATB3/ATD3 ATB2/ATD2 ATB1/ATD1 ATB0/ATD0 PA7 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 R13 ³ýʪָʾµÆ ÖÆÈÈָʾµÆ +5 10K CX1 4M ¸ºÀë×Ó 1 ÖÆÀäָʾµÆ ÔËÐÐָʾµÆ ¶¨Ê±Ö¸Ê¾µÆ ½¡¿µÖ¸Ê¾µÆ C4 100u/16v C17 104/50V 10K C18 104 +5 R6 10K R1 +5 1K XT SW C22 103 C20 C21 102 CN4 +5 102 +12 CN5 +12 ×ÏÍâÏß Q6 9013 R35 330 CN7 Ï°ڷ粽½øµç»ú R31 10K 12V ÉÏ°Ú·ç²½½øµç»ú 31 C8 4.7UF/50V C7 4.7UF/50V 1 2 IC3 2803 104/50V R26 10K Ëõʱ +5 C33 R37 1K 2 1 C5 100u/16v C19 104/50V 908AB32 +5 Q8 9013 R10 +5 D Q4 9013 1 RL1 JQ1a-12V D8 1N4007 CN10 9 8 7 6 5 4 3 2 1 RC1 +12 +5 24C02A PTC4 IRQ RST PTF0/TACH2 PTF1/TACH3 PTF2/TACH2 PTF3/TACH3 PTF4/TACH0 NC PTF7 PTF5/TBCH1 PTF6 PTE0/TXD PTE1/RXD PTE2/TACH0 PTE3/TACH1 PTE4/SS PTE5/MISO PTE6/MOSI PTE7/SPSCK VSS VDD PTG0/KBD0 PTG1/KBD1 PTG2/KBD2 PA0 PA1 PA2 PA3 PA4 PA5 PA6 10 11 12 13 14 15 16 17 18 1 2 3 +5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ·çËÙÑ¡Ôñ 24 25 26 27 28 29 30 31 32 1 2 3 4 5 6 7 8 9 10 CN8 1 220VL SW1 8 7 SCL 65 IC1 C28 104 +5V +5 R36 10K C23 103 R14 R42 Q7 9013 CN2 IC2 102 R12 10K +5 IC5 1K C29 C26 102 1M 1 2W6.8K C25 104 10K R32 1 2 R9 3k ·çËÙÑ¡Ôñ R34 3 LED +5 R33 10K R38 2 100 R24 1 12V R23 ×ÏÍâÏß CN1 ÊÒΠR2 1K R3 1K ÅÌ¹Ü 4 3 2 1 R5 20K 1% R4 3.3K 1% ½¡¿µÖ¸Ê¾µÆ ¶¨Ê±Ö¸Ê¾µÆ ÔËÐÐָʾµÆ ÖÆÀäָʾµÆ ³ýʪָʾµÆ ÖÆÈÈָʾµÆ Ò£¿Ø½ÓÊÕ +5 1 2 3 4 5 6 7 8 9 Wiring diagram unit WIRING DIAGRAM,INDOOR SIGNAL RECEIVER BOARD AMBIENT TEMP. SENSOR M 0010546148 FAN MOTOR PIPING TEMP. SENSOR louver motor R W CN4 CN3 CN2 CN1 SW ION GENERATOR louver motor CN8 CN5 CN6 CN7 CON1- 2 T3.15A/ 250VAC CN10 FUSE indoor CN14 Y/ G CN16 CON1- 1 CN11 CN15 W B R 1(N) 2(L) 3(C) TO OUTDOOR UNIT Y/ G R: RED BL: BLUE BR: BROWN NOTE: W: WHITE WHEN THE UNIT HAS NOT THE FUNCTION OF HEALTH WITHOUT THE PARTS IN THE DOTTED LINE. B: BLACK Y/ G: YELLOW/ GREEN 32 Wiring diagram outdoor unit LW HW LV HV LU HU 0V 5V 13V ARM COMP. RS C B N - R WB W V U + P R Y 200uF/250V CAPACITOR CN7 CN8 CN9 SUCTION TEMP. SENSOR CN10 R + 1 - BRIDGE VECTIFIER B R B R A W CN4 4-WAY VALVE R W CN23 CN5 CN6 CN2 CN22 A(C) A(L) A(N) B(C) B(L) B(N) L N POWER PLUG 7363647 Y/G W B BR FUSE B W 250V/25A POWER RELAY R FAN MOTOR G B CN3 CN21 CN20 CN17 CN19 EXPANSION VALVE CN14 CN16 EXPANSION VALVE CN13 CN12 CN11 EVAPORATER TEMP. SENSOR DISCHARGE TEMP. SENSOR B A 2 BRIDGE VECTIFIER - DEFROST TEMP. SENSOR ROOM B + TEMP. SENSOR B B WIRING DIAGRAM OF OUTDOOR UNIT BL Y G B + - W + - GREY WHITE 1 CAPACITOR 2 200uF/250V + CAPACITOR - B W: OR ORANGE Y/G: YELLOW/GREEN G: REACTOR YELLOW BLACK Y: B: BLUE RED BROWN R: BR: BL: 33 Abnormity diagnose 34 Abnormity diagnose 1. Abnormity diagnose For the appeared abnormal phenomena, please refer to the following table for trouble analysis and troubleshooting: List of error code: Error display Abnormity mode Indoor Outdoo r Automati c restore Possible reason Running Heat Cool Abnormity of indoor thermistor ★ ■ ■ * * 1. Inserter does not contact well or control board is not good. Abnormity of thermal conversion thermistor ★ □ □ * * 1. Inserter does not contact well or control board is not good. Abnormity of defrosting thermistor □ □ ★ * * 1. Inserter does not contact well or control board is not good. Abnormity discharging thermistor ★ □ ■ * * 1. Inserter does not contact well or control board is not good. Abnormity of control board thermistor □ ■ ★ * * 1. Inserter does not contact well or control board is not good. Abnormity of module thermistor □ ★ □ * * 1. Inserter does not contact well or control board is not good. Abnormity of outdoor thermistor □ ★ ■ * * 1. Inserter does not contact well or control board is not good. of * Transmission abnormity ■ Compressor running abnormity ★ ■ □ * Overhigh discharging temperature protection ■ ★ ■ * ■ ★ * 1. There is great interference source around 2. Incorrect wire connection or control board is not good. 1. Check if compressor shaft is seized. 2. Whether power module is damaged 1. Whether system gas is insufficient or charged gas is too much. 2. Whether system voltage is too high (above242V) or too low (below 187V) 3. Whether capillary tube is blocked. 4. Whether sensors or control board components are abnormal. 5. Whether the indoor/outdoor ambient temperature is too high. 1. AC protection current ★ ★ ■ * 2. 3. 35 Whether system is charged too many gases. Whether voltage is too low (below 187V). Whether CT or control board component is abnormal. Abnormity diagnose 1. DC protection current Insufficient protection current 2. ★ ★ □ * 3. Outdoor control board temperature protection ■ ■ ★ ★ □ * ★ * 1. 2. Whether voltage is too low. Whether control board damaged. 1. Whether control board is abnormal. Whether outdoor ambient temperature is too high. 2. 1. 2. Module temperature rising protection □ ★ ★ * 3. 4. 1. 2. 3. High-load protection ★ ★ ★ * 4. 5. 1. CT wiring disconnected protection ★ ■ ★ * 2. 3. * EEPROM abnormity ★ □ □: Lightening ★: Flashing ■: Blackout is Whether compressor shaft is seized. Whether power module is damaged. Whether heat emission glue is evenly distributed. Whether system voltage is too high (above242V) or too low (below 187V) Whether filter is blocked. Whether the indoor/outdoor ambient temperature is too high Whether system is charged too much gases. Whether control board component is damaged. Whether voltage is too high or too low. Whether control board is damaged. Whether 4-way valve is converted. Whether charged gas is normal 1. Whether control damaged. board is 2. Whether control damaged. board is ★ * Note: Whether compressor shaft is seized. Whether power module is damaged. Whether system voltage is too high (above242V) or too low (below 187V) * Indicating that this function is provided. 36 Abnormity diagnose The warning LED of outdoor PCB blinking times show the abnormalty as below: 1 time, pipe temperature sensor A faulty; 2 time, pipe temperature sensor B faulty; 3 time, evaporating temperature sensor faulty; 4 time, suction temperature sensor faulty; 5 time, defrosting temperature sensor faulty; 6 time, discharging temperature sensor faulty; 37 Trouble shooting 37 38 Refrigerating cycle diagram 39 40 Noise level test chart and air velocity distribution 41 42 43 Installation and accessory parts 44 12 C 8 D 15 E The 45 G 3/8 46 12.7mm(1/2") 47 48 Singal line H2SM-18RA03/R1 H2SM-18RA03/R1(B) 49 50 (R407C) 3.The purging Method of the indoor unit B is the same as the indoor unit A. 51 9.52 3/8 12.7mm (1/2") 9.52 3/8 12.7mm (1/2") 52 53
Similar documents
Daitsu Air-conditioner
2.High energy efficient The design of inner-grooved copper tube greatly increases the refrigerant contact area and the efficiency of cooling/heating functions.Using the R410A refrigerant and the re...
More information