CIRCUIT PROTECTION
SENTRY
RANGE INTRODUCTION
The Sentry range of Consumer
Units from MK Electric has
been stylishly designed to
blend in with its environment.
The curved lines and slim-line
appearance mean it won’t look
out of place when installed in
hallways, lounges or kitchens
of new properties.
The expanded range includes a 21-module unit
for larger installations and also a 4-module unit to
cater for small one-off installations and extensions
to existing ones.
SUPPORTS 17TH EDITION AMENDMENT 3 COMPLIANCE
Full range of products to support compliance with the 17th Edition Amendment 3
of the Wiring Regulations, including Full Metal non-combustible enclosures for
Consumer Units.
MK ELECTRIC DESIGN SERVICE FOR PRE-ASSEMBLED CONSUMER UNITS
Save time and money by specifying project requirements through the MK Electric
Design Service. Pre-assembled custom built boards, with all devices pre-fitted
with busbars and cables are available to suit any installation.
FLOATING BUSBAR SYSTEM
Gives maximum installation flexibility.
BROAD SELECTION OF PRE-ASSEMBLED SPLIT LOAD UNITS AVAILABLE
Suits a variety of applications and saves installation time.
HOW TO SPECIFY
The MK Electric Design Service offers a preassembly service for custom built boards with all
devices fitted, busbars cut and fitted with devices,
live and neutral cables terminated.
A metal range of consumer unit and accessories (Switch’s MCB’s, RCD’s &
RCBO’s) designed to comply to the 17th Edition Amendment 3 of the wiring
regulations (BS 7671:2008). Consumer unit doors must be top hinged to ensure
the door is closed when the unit is not in use. The base, lid & door of the
consumer unit must be earthed to provide safe operation at all times. A floating
busbar system to be employed to ensure maximum installation flexibility and
acceptance of control devices. All consumer units must have a curved door to
prevent dust collection and offer a unobtrusive appearance that blends into the
environment. Backed out captive screws, removable DIN rails and sufficient wiring
space are required to ensure ease of installation and maintenance.
MK Electric Catalogue
271
CIRCUIT PROTECTION
Sentry
mkelectric.co.uk
MK Sentry Consumer Unit Features and Benefits
NEW: Top Hinged Door
Prevents door being left
open after use leading to a
possible fire risk
NEW: Manufactured from
Zintec Steel
Corrosion resistant material which
ensures full compliance with 17th
Edition Amendment 3
NEW: Multiple extra
large knock outs
Aides and eases
installation
NEW: Continual
Earthing
Only need to earth
once via the base
Curved Stylish Design
Broad Selection Available
NEW: MK White Colour
Modernised aesthetics for visible installations.
Design service available for bespoke requests
272
mkelectric.co.uk
Suits a variety of applications
Blends into the environment
Backed out and captive
combi-head screws
CIRCUIT PROTECTION
Sentry
Technical Hotline
+44 (0)1268 563720
Fixing holes
Allows simple and speedy installation
Easily removable Din Rail
Simplifying and easing first fix
Tripod fixing to cope
with uneven surfaces
Colour coded earth and
neutral terminal locked
At top of unit for ease of wiring
NEW: 10mm
Increased Height
Additional wiring space
NEW: Supporting
Din Rail
“T” Bar
Additional support
to prevent bowing
and twisting which
has been raised for
improved cable routing
Floating busbar
system
For maximum
installation flexibility
including acceptance
of control modules
CONSUMER UNIT SELECTION GUIDE
STEP 1
Determine the type of consumer unit configuration required. e.g Split Load,
Standard or combination of split load / single RCD or dual RCD. For each Switch
Disconnector or RCD to be used allow 2 modular ways.
STEP 2
Determine the number of outgoing circuits required. e.g Cooker, Lighting, Ring Main
etc. For each circuit to be protected by an MCB or RCBO allow 1 modular way.
STEP 3
Determine what control products are required. e.g Bell Transformer, Time Delay
Switch, contactors, timeswitches etc.
STEP 4
Determine the number of ‘spare’ modular ways required for future upgrades. For
each ‘spare’ modular way select 1 Sentry blank module – 5544s or K5545sMAG
(cover mounted blanks supplied with consumer units. See page 286).
STEP 5
Now add together the total number of modular ways required.
STEP 6
Select from our range of Insulated, Metal, Flush or stacked consumer units (using
standard consumer units plus stacking kits). Choose the type and size most
appropriate for your requirements.
Offset Incomer
Provides additional wiring
space making mains input
connections easier
MK Electric Catalogue
273
CIRCUIT PROTECTION
Sentry
mkelectric.co.uk
The MK Electric Design Service
THE MK ELECTRIC DESIGN SERVICE IS PERFECT FOR WHEN ONLY A
CUSTOMISED SOLUTION CAN MEET YOUR REQUIREMENTS, OR WHEN FULLY
ASSEMBLED CONSUMER UNITS CAN BE PROVIDED FOR YOUR PROJECT TO
SAVE YOU INSTALLATION TIME.
Our dedicated team can help you to build the best configurations for your project, and then assemble the boards ready
for installation. Using standard and non-standard Sentry components we can build and supply fully assembled units to
an agreed design. For example, have your split load boards supplied with all the devices pre-fitted with busbars and
cables to suit the installation This service is ideal for housing developers, or any project application*.
*Minimum order quantity of 20 of the same design
•
Dedicated team on hand to build configuration to meet your needs
•
Service is available for all MK Consumer Units
•
Faster installation time on site
•
Fast turnaround – 1 working day response time to initial enquiry
To find out more visit www.mkelectric.co.uk and follow the links to the Design Service.
274
STEP 1
Call the MK Electric Technical Services Team on 01268 563720 or email mk.technical@honeywell.com
STEP 2
Discuss the details of your project and circuit protection requirements with a member of the
MK Technical Services Team or complete the online enquiry and click send
STEP 3
Within one working day you will have a response to your initial enquiry
STEP 4
Confirm the configurations and quantities
STEP 5
Receive the quote for your order
STEP 6
Place your order with your wholesaler
STEP 7
Your order will be delivered to the wholesaler of your choice. All boards will be fully assembled
and ready for installation
mkelectric.co.uk
CIRCUIT PROTECTION
Sentry
Technical Hotline
+44 (0)1268 563720
Consumer Units
METAL
ENCLOSURE + SWITCH
DISCONNECTOR
SURFACE
METAL
ENCLOSURE ONLY
SURFACE
K5704sMET
K5604sMET
K5716sMET
K5616sMET
K5708sMET
K5608sMET
K5621sMET
K5721sMET
K5712sMET
K5612sMET
K5604SMET1
4 WAY ENCLOSURE
ACCEPTS 4 ONE MODULE PRODUCTS
(1 INTEGRAL NEUTRAL BAR)
K5608SMET1
8 WAY ENCLOSURE
ACCEPTS 8 ONE MODULE PRODUCTS
(1 INTEGRAL NEUTRAL BAR)
K5612SMET1
12 WAY ENCLOSURE
ACCEPTS 8 ONE MODULE PRODUCTS
(2 INTEGRAL NEUTRAL BARS FITTED
WITH LINKS)
All units are white coloured.
All units feature a robust galvanized metal base,
lid & door.
The DIN rail embodies a useful alignment and
fixing mechanism that allows quick installation.
Cable entry points are located on top, bottom,
side and rear surfaces.
DIMENSIONS:
4 WAY
8 WAY
12 WAY
16 WAY
21 WAY
Width
144
238
310
382
472
x
x
x
x
x
Height
244
244
244
244
244
x
x
x
x
x
K5616SMET1
K5704SMET1
K5716SMET1
K5621SMET1
K5708SMET1
K5721SMET1
21 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
ACCEPTS A FURTHER 19 ONE MODULE
PRODUCTS
16 WAY ENCLOSURE
ACCEPTS 16 ONE MODULE PRODUCTS
(3 INTEGRAL NEUTRAL BARS FITTED
WITH LINKS)
21 WAY ENCLOSURE
ACCEPTS 21 ONE MODULE PRODUCTS
(3 INTEGRAL NEUTRAL BARS FITTED
WITH LINKS)
4 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
ACCEPTS A FURTHER 2 ONE MODULE
PRODUCTS
8 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
ACCEPTS A FURTHER 6 ONE MODULE
PRODUCTS
16 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
ACCEPTS A FURTHER 14 ONE MODULE
PRODUCTS
K5712SMET1
12 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
ACCEPTS A FURTHER 10 ONE MODULE
PRODUCTS
MAIN INCOMER RATING:
4 way enclosures: 63A
8, 12, 16 & 21 way enclosures: 100A
Degree of protection to BS EN 60529 to IP2XC.
Precautions must be taken to maintain the IP
rating, e.g. Use of cable glands and knockouts.
BS EN 61439-3
Depth
116mm
116mm
116mm
116mm
116mm
FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer
units with your required Sentry components
All units are pre-fitted with a switch disconnector
DIMENSIONS:
4 WAY
8 WAY
12 WAY
16 WAY
21 WAY
Width
144
238
310
382
472
x
x
x
x
x
Height
244
244
244
244
244
x
x
x
x
x
Depth
116mm
116mm
116mm
116mm
116mm
MAIN INCOMER RATING:
4 way enclosures: 63A
8, 12, 16 & 21 way enclosures: 100A
Degree of protection to BS EN 60529 to IP2XC.
Precautions must be taken to maintain the IP
rating, e.g. Use of cable glands and knockouts.
BS EN 61439-3
Cover mounted blanks are supplied with ALL consumer units
(2 off x 1 for 4, 8 and 12 way enclosures and 2 off x 2 for 16 and 21 way enclosures)
MK Electric Catalogue
275
CIRCUIT PROTECTION
Sentry
mkelectric.co.uk
Consumer Units
SPLIT-LOAD
SINGLE RCD ARRANGEMENTS
METAL
SURFACE
K5682sMET
SPLIT-LOAD
DUAL RCD ARRANGEMENTS
METAL
SURFACE
K5662sMET
K5666sMET
K5687sMET
K5682SMET
1
12 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
63A 30mA RCD
ACCEPTS A FURTHER 8 ONE MODULE
PRODUCTS
K5662SMET
1
K5666SMET
1
16 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
2 X 63A 30mA RCD’S
ACCEPTS A FURTHER 10 ONE MODULE
PRODUCTS
K5683SMET
K5689SMET
K5685SMET
1
K5688SMET
1
K5687SMET
1
21 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
2 X 80A 30mA RCD’S
ACCEPTS A FURTHER 15 ONE MODULE
PRODUCTS
K5684SMET
1
K5686SMET
1
K5681SMET
16 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
63A 30mA RCD
ACCEPTS A FURTHER 12 ONE MODULE
PRODUCTS
1
12 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
80A 30mA RCD
ACCEPTS A FURTHER 8 ONE MODULE
PRODUCTS
16 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
80A 30mA RCD
ACCEPTS A FURTHER 12 ONE MODULE
PRODUCTS
21 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
80A 30mA RCD
ACCEPTS A FURTHER 17 ONE MODULE
PRODUCTS
All units are white coloured.
All units are pre-fitted with a switch disconnector
and RCD together with all the necessary
split-load cabling. The flexibility of design allows
the RCD to be positioned to suit the required
configuration of RCD protected and non-protected
circuits, subject to the rating of either the switch
or RCD not being exceeded. MK recommends
the use of RCBO’s for non RCD protected circuits
to comply with the 17th Edition Amendment 3
Wiring Regulations.
DIMENSIONS:
4 WAY
276
Width
Height
Depth
144 x 244 x 116mm
8 WAY
238 x 244 x 116mm
12 WAY
310 x 244 x 116mm
16 WAY
382 x 244 x 116mm
21 WAY
472 x 244 x 116mm
MAIN INCOMER RATING:
4 way enclosures: 63A
8, 12, 16 & 21 way enclosures: 100A
Degree of protection to BS EN 60529 to IP2XC.
Precautions must be taken to maintain the IP
rating, e.g. Use of cable glands and knockouts.
BS EN 61439-3
FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling
consumer units with your required Sentry components
16 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
2 X 80A 30mA RCD’S
ACCEPTS A FURTHER 10 ONE MODULE
PRODUCTS
16 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
1 X 63A & 1 X 80A 30mA RCD’S
ACCEPTS A FURTHER 10 ONE MODULE
PRODUCTS
All units are white coloured.
All units are pre-fitted with a switch disconnector
and RCD together with all the necessary
split-load cabling. The flexibility of design allows the
RCD to be positioned to suit the required
configuration of RCD protected and non-protected
circuits, subject to the rating of either the switch
or RCD not being exceeded. MK recommends the
use of RCBO’s for non RCD protected circuits to
comply with the 17th Edition Amendment 3 Wiring
Regulations.
DIMENSIONS:
4 WAY
Width
Height
Depth
144 x 244 x 116mm
21 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
2 X 63A 30mA RCD’S
ACCEPTS A FURTHER 15 ONE MODULE
PRODUCTS
21 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
1 X 63A & 1 X 80A 30mA RCD’S
ACCEPTS A FURTHER 15 ONE MODULE
PRODUCTS
1
1
8 WAY
238 x 244 x 116mm
12 WAY
310 x 244 x 116mm
16 WAY
382 x 244 x 116mm
21 WAY
472 x 244 x 116mm
MAIN INCOMER RATING:
4 way enclosures: 63A
8, 12, 16 & 21 way enclosures: 100A
Degree of protection to BS EN 60529 to IP2XC.
Precautions must be taken to maintain the IP rating,
e.g. Use of cable glands and knockouts.
BS EN 61439-3
Cover mounted blanks are supplied with ALL consumer units
(2 off x 1 for 4, 8 & 2 way enclosures and 2 off x 2 for 16 & 21 way enclosures)
CIRCUIT PROTECTION
Sentry
Technical Hotline
+44 (0)1268 563720
FULLY POPULATED
ARRANGEMENTS
METAL
SURFACE
K6550sMET
K7673sMET
K6551sMET
K7663sMET
K7665sMET
K6552sMET
K7664sMET
K7666sMET
K7678sMET
K6550SMET1
K7673SMET1
K6551SMET1
4 WAY ENCLOSURE
63A 30mA RCD
1 X MCB (1 X 50A)
4 WAY ENCLOSURE
63A 30mA RCD
2 X MCB’S (1 X 6A & 1 X 16A)
K7663SMET1
12 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
63A 30mA RCD
6 X MCB’S (2 X 6A, 2 X 16A & 2 X 32A)
2 X RCBO’S (1 X 6A & 1 X 40A)
K7664SMET1
12 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
2 X 63A 30mA RCD’S
6 X MCB’S (2 X 6A, 1 X 16A, 2 X 32A &
1 X 40A)
All units are white coloured.
All units are pre-fitted with a switch disconnector
and RCD together with all the necessary split-load
cabling. The flexibility of design allows the RCD to
be positioned to suit the required configuration of
RCD protected and non-protected circuits, subject
to the rating of either the switch or RCD not being
exceeded.
12 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
6 X RCBO’S (2 X 6A, 1 X 16A, 2 X 32A &
1 X 40A)
ACCEPTS A FURTHER 4 ONE MODULE
PRODUCTS
K7665SMET1
16 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
2 X 63A 30mA RCD’S
8 X MCB’S (2 X 6A, 2 X 16A, 3 X 32A &
1 X 40A)
ACCEPTS A FURTHER 2 ONE MODULE
PRODUCTS
K7666SMET1
16 WAY ENCLOSURE
100A SWITCH DISCONNECTOR
2 X 63A 30mA RCD’S
10 X MCB’S (3 X 6A, 2 X 16A, 4 X 32A &
1 X 40A)
MK recommends the use of RCBO’s for non RCD
protected circuits to comply with the 17th Edition
Amendment 3 Wiring Regulations.
DIMENSIONS:
4 WAY
8 WAY
12 WAY
16 WAY
21 WAY
Width
144
238
310
382
472
x
x
x
x
x
Height
244
244
244
244
244
x
x
x
x
x
Depth
116mm
116mm
116mm
116mm
116mm
K6552SMET1
8 WAY ENCLOSURE
63A 30mA RCD
6 X MCB’S
(3 X 6A, 1 X 16A & 2 X 20A)
K7678SMET1
21 WAY ENCLOSURE
1 X 63A & 1 X 80A 30mA RCD’S
12 X MCB’S
(3 X 6A, 2 X 16A, 2 X 20A,
4 X 32A & 1 X 40A)
ACCEPTS A FURTHER 3 ONE MODULE
PRODUCTS
MAIN INCOMER RATING:
4 way enclosures: 63A
8, 12, 16 & 21 way enclosures: 100A
Degree of protection to BS EN 60529 to IP2XC.
Precautions must be taken to maintain the IP rating,
e.g. Use of cable glands and knockouts.
BS EN 61439-3
FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components
MK Electric Catalogue
277
CIRCUIT PROTECTION
Sentry
mkelectric.co.uk
Consumer Units
Switch
Disconnectors
Double Pole
INSULATED
SURFACE
TWO MODULE
K5604sMAG
K5612sMAG
5500s
K5608sMAG
K5616sMAG
K5621sMAG
K5604SMAG1
4 WAY ENCLOSURE
ACCEPTS 4 ONE MODULE PRODUCTS
(1 INTEGRAL NEUTRAL BAR)
K5608SMAG1
8 WAY ENCLOSURE
ACCEPTS 8 ONE MODULE PRODUCTS
(1 INTEGRAL NEUTRAL BAR)
All units are magnolia coloured.
All units feature a robust base together with an all over front
cover and moulded lid in an impact resistant, flame retardant
thermoplastic. Cable entry points are located on top, bottom, side
and rear surfaces.
DIMENSIONS:
K5604sMAG
K5608sMAG
K5612sMAG
K5616sMAG
K5621sMAG
Width
140
234
306
378
468
x
x
x
x
x
Height
230
230
230
230
230
x
x
x
x
x
Depth
110mm
110mm
110mm
110mm
110mm
MAIN INCOMER MAXIMUM RATING
K5604sMAG and K5504sMAG: 63A
All other consumer units: 100A
K5612SMAG1
12 WAY ENCLOSURE
ACCEPTS 12 ONE MODULE PRODUCTS
(2 INTEGRAL NEUTRAL BARS
FITTED WITH LINK)
K5616SMAG1
16 WAY ENCLOSURE
ACCEPTS 16 ONE MODULE PRODUCTS
(3 INTEGRAL NEUTRAL BARS
FITTED WITH LINK)
K5621SMAG1
21 WAY ENCLOSURE
ACCEPTS 21 ONE MODULE PRODUCTS
(4 INTEGRAL NEUTRAL BARS
FITTED WITH LINKS)
K5687SMAG17ED1
Degree of protection to BS EN 60529 to IP2XC.
Precautions must be taken to maintain the IP rating, e.g. use of
cable glands and knockouts.
BS EN 60439-3:1999
FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling
consumer units with your required Sentry components
278
mkelectric.co.uk
5560s
5500s5
100A 230V
5560s5
63A 230V
Suitable for installation in Sentry Consumer Units and two or four
module enclosures. Accepts direct to busbar or cable-in / cable-out
connection.
CATEGORY OF DUTY:
AC22A for switching of resistive and inductive loads.
Positive contact status indication in accordance with 17th Edition IEE
Wiring Regulations
(537.2.2.2 and 537.3.2.2)
DIMENSIONS:
81 x 36 x 76mm
CABLE CAPACITY:
50mm²
BS EN 60947-3:1999
MCBs
Single Pole
MCB
Single Pole
TYPE B
ONE MODULE
TYPE C
ONE MODULE
5903s
5910s
5906s
5916s
CIRCUIT PROTECTION
Sentry
Technical Hotline
+44 (0)1268 563720
5920s
5945s
5940s
8703s
8706s
8720s
8732s
8710s
8716s
8740s
8750s
5950s
5903s10
5920s10
20A 230V
3A 230V
8703s10
8720s10
5906s10
5925s10
8706s10
8725s10
5910s10
5932s10
8710s10
8732s10
5916s10
5940s10
8716s10
8740s10
3A 230V
6A 230V
10A 230V
16A 230V
Suitable for installation in Sentry Consumer Units
and two or four module enclosures.
Positive contact status indication in accordance
with 17th Edition IEE Wiring Regulations
(537.2.2.2 and 537.3.2.2)
DIMENSIONS:
83 x 18 x 74mm
CABLE CAPACITY:
35mm²
Short-circuit breaking capacity: 6KA
BS EN 60898:2003
25A 230V
32A 230V
40A 230V
5945s10
45A 230V
5950s10
50A 230V
Suitable for installation in Sentry Consumer Units
and two or four module enclosures.
Positive contact status indication in accordance
with 17th Edition IEE Wiring Regulations
(537.2.2.2 and 537.3.2.2)
DIMENSIONS:
83 x 18 x 74mm
CABLE CAPACITY:
35mm²
SHORT-CIRCUIT BREAKING CAPACITY:
6KA
BS EN 60898:2003
6A 230V
10A 230V
16A 230V
Suitable for installation in Sentry Consumer Units
and two or four module enclosures.
Positive contact status indication in accordance
with 17th Edition IEE Wiring Regulations
(537.2.2.2 and 537.3.2.2)
DIMENSIONS:
83 x 18 x 74mm
CABLE CAPACITY:
35mm²
SHORT-CIRCUIT BREAKING CAPACITY:
6KA
BS EN 60898:2003
20A 230V
25A 230V
32A 230V
40A 230V
8750s10
50A 230V
8763s10
63A 230V
Suitable for installation in Sentry Consumer Units
and two or four module enclosures.
Positive contact status indication in accordance
with 17th Edition IEE Wiring Regulations
(537.2.2.2 and 537.3.2.2)
DIMENSIONS:
83 x 18 x 74mm
CABLE CAPACITY:
35mm²
SHORT-CIRCUIT BREAKING CAPACITY:
6KA
BS EN 60898:2003
MK Electric Catalogue
279
CIRCUIT PROTECTION
Sentry
mkelectric.co.uk
RCBOs
With Solid Neutral
Single Pole
Residential 6kA RCD
Double Pole
Type AC
TYPE B
ONE MODULE
7932s
16 AMP
TWO MODULE
TYPE C
ONE MODULE
7933s
7934s
7935s
8932s
8933s
8934s
7816s
7936s
7937s
7932s1
6A 230V
30mA
TRIPPING CURRENT
7933s1
10A 230V
30mA
TRIPPING CURRENT
7934s1
16A 230V
30mA
TRIPPING CURRENT
Suitable for installation in Sentry Consumer Units.
Positive contact status indication in accordance
with 17th Edition IEE Wiring Regulations
(537.2.2.2 and 537.3.2.2)
DIMENSIONS:
119 x 18 x 73mm
CABLE CAPACITY:
Live 25mm²,
Neutral 25mm²
SHORT CIRCUIT BREAKING CAPACITY:
6KA
BS EN 61009-1
BS IEC 61009-2-2
280
mkelectric.co.uk
7938s
7939s
7935s1
20A 230V
30mA TRIPPING CURRENT
7936s1
32A 230V
30mA TRIPPING CURRENT
7937s1
40A 230V
30mA TRIPPING CURRENT
7938s1
45A 230V
30mA TRIPPING CURRENT
7939s1
50A 230V
30mA TRIPPING CURRENT
8935s
8936s
8932s1
6A 230V
30mA
TRIPPING CURRENT
8933s1
10A 230V
30mA
TRIPPING CURRENT
8934s1
16A 230V
30mA
TRIPPING CURRENT
8935s1
20A 230V
30mA
TRIPPING CURRENT
8936s1
32A 230V
30mA
TRIPPING CURRENT
7816s1
16A 230V
30mA TRIPPING CURRENT
32 AMP
TWO MODULE
7832s
7832s1
32A 230V
30mA TRIPPING CURRENT
CIRCUIT PROTECTION
Sentry
Technical Hotline
+44 (0)1268 563720
40 AMP
TWO MODULE
63 AMP
TWO MODULE
80 AMP
TWO MODULE
7860s
7880s
7660s
7680s
7860s1
7880s1
7560s1
7580s1
7840s
7840s1
40A 230V
30mA TRIPPING CURRENT
63A 230V
30mA TRIPPING CURRENT
63A 230V
100mA
TRIPPING CURRENT
7660s1
63A 230V
300mA TRIPPING CURRENT
80A 230V
30mA TRIPPING CURRENT
80A 230V
100mA TRIPPING CURRENT
7680s1
80A 230V
300mA TRIPPING CURRENT
MK Electric Catalogue
281
CIRCUIT PROTECTION
Sentry
mkelectric.co.uk
Industrial 10kA RCDs
Double Pole
Type AC
16 AMP
TWO MODULE
32 AMP
TWO MODULE
6016s
6032s
6316s
6730s
6016s1
6032s1
6416s1
6730s1
16A 110V
10mA TRIPPING
CURRENT
16A 110V
30mA TRIPPING
CURRENT
32A 110V
30mA TRIPPING
CURRENT
32A 230V
30mA TRIPPING
CURRENT
6316s1
16A 230V
10mA TRIPPING
CURRENT
5716s1
16A 230V
30mA TRIPPING
CURRENT
282
mkelectric.co.uk
40 AMP
TWO MODULE
5740s
5740s1
40A 230V
30mA TRIPPING
CURRENT
63 AMP
TWO MODULE
80 AMP
TWO MODULE
100 AMP
TWO MODULE
5760s
6080s
6600s
5860s
5880s
7800s
5760s1
6080s1
7700s1
6160s1
5780s1
6600s1
5860s1
6180s1
7800s1
63A 230V
30mA TRIPPING
CURRENT
63A 230V
100mA TRIPPING
CURRENT
63A 230V
300mA TRIPPING
CURRENT
80A 110V
30mA TRIPPING
CURRENT
80A 230V
30mA TRIPPING
CURRENT
80A 230V
100mA TRIPPING
CURRENT
5880s1
80A 230V
300mA TRIPPING
CURRENT
100A 230V
30mA TRIPPING
CURRENT
100A 230V
100mA TRIPPING
CURRENT
100A 230V
300mA TRIPPING
CURRENT
Suitable for installation in
Sentry Consumer Units and
two or four module enclosures.
Positive contact status
indication in accordance
with 17th Edition IET Wiring
Regulations (537.2.2.2 and
537.3.2.2)
DIMENSIONS:
85 x 36 x 75mm
CABLE CAPACITY:
50mm²
BS EN 61008:1995
Industrial 10kA RCDs
Pulsating d.c.
Fault Current Sensitive
Double Pole Type A
Industrial 10kA
RCDs
Time Delayed
Double Pole
TWO MODULE
TWO MODULE
6216s
5640s
6980s
6630s
6216s1
16A 230V
10mA TRIPPING CURRENT
6630s1
32A 230V
30mA TRIPPING CURRENT
5640s1
40A 230V
30mA TRIPPING CURRENT
5660s1
63A 230V
30mA TRIPPING CURRENT
Suitable for installation in Sentry Consumer Units
and two or four module enclosures.
Positive contact status indication in accordance
with 17th Edition IET Wiring Regulations
(537.2.2.2 and 537.3.2.2)
DIMENSIONS:
85 x 36 x 75mm
CABLE CAPACITY:
50mm2
BS EN 61008:1995
CIRCUIT PROTECTION
Sentry
Technical Hotline
+44 (0)1268 563720
Industrial 10kA RCDs
Four Pole
Type AC
25 AMP
FOUR MODULE
6425s
80A 230V
100mA TRIPPING CURRENT
TIME DELAYED
6400s1
100A 230V
100mA TRIPPING CURRENT
TIME DELAYED
Suitable for installation in Sentry Consumer
Units and Four Module enclosures. When used
as a mains incomer these units will provide
discrimination with downstream instantaneously
operating 10mA or 30 mA RCD’s. For example,
they can be used as main incomers on split load
consumer units where it is not desirable, because
of the possibility of unwanted tripping, to place
all of the circuits on an instantaneous 30mA
RCD, but where earth leakage protection is still
required for these circuits or where compliance
is required to the indirect contact protection
requirements of the IET Wiring Regulations.
6440s
6240s
6400s
6980s1
40 AMP
FOUR MODULE
6425s1
25A 230/400V
30mA TRIPPING CURRENT
Suitable for installation in Sentry four module
enclosures and Commando Combi.
Positive contact status indication in accordance
with 17th Edition IET Wiring Regulations
(537.2.2.2 and 537.3.2.2)
DIMENSIONS:
85 x 72 x 75mm
CABLE CAPACITY:
50mm2
BS EN 61008:1995
6440s1
40A 230/400V
30mA TRIPPING CURRENT
6240s1
40A 230/400V
100mA TRIPPING CURRENT
DIMS: 81 x 36 x 76mm
CABLE CAPACITY: 50mm2
BS EN 61008:1995
NOT TO BE USED FOR PERSONAL PROTECTION
AGAINST ELECTRIC SHOCK
FACTORY BUILT SERVICE
MK can save you time and money by
pre-assembling consumer units with your
required Sentry components
MK Electric Catalogue
283
CIRCUIT PROTECTION
Sentry
Industrial 10kA
RCDs Four Pole
Type AC
63 AMP
FOUR MODULE
6463s
mkelectric.co.uk
Industrial 10kA RCD
Contactors
Pulsating d.c.
Fault Current
Sensitive, Four Pole
Type A
FOUR MODULE
6640s
6363s
6463s1
63A 230/400V
30mA TRIPPING CURRENT
6363s1
63A 230/400V
100mA TRIPPING CURRENT
6263s1
63A 230/400V
300mA TRIPPING CURRENT
6640s1
40A 230/400V
30mA TRIPPING CURRENT
Suitable for installation in Sentry two
or four module enclosures.
Positive contact status indication
in accordance with 17th Edition IET
Wiring Regulations
(537.2.2.2 and 537.3.2.2)
DIMENSIONS:
85 x 72 x 75mm
CABLE CAPACITY:
50mm2
BS EN 61008:1995
ONE MODULE
TWO MODULE
THREE MODULE
6220s
7240s
7440s
6720s
7263s
7463s
20A
DOUBLE POLE
20A
FOUR POLE
6420s1
7440s1
6720s1
7240s1
7463s1
6220s1
20A
DOUBLE POLE
WITH MANUAL OVERRIDE
Suitable for installation in Sentry
Consumer Units and two or four
module enclosures. Automatically
switches higher loads than possible
with a time switch eg; off peak tariffs.
A manual override enables the
temporary setting of the contactor in
either the on or off position in addition
to normal automatic operation.
When a contactor is mounted
alongside an MCB of greater than 10
amp current rating or two contractors
are mounted alongside an MCB or
side by side, it is necessary to insert
a blank module between them (list
no.5544s)
40A
DOUBLE POLE
40A
FOUR POLE
63A
FOUR POLE
7263s1
63A
DOUBLE POLE
CONTACTOR RATINGS:
List no
6220s
6420s
6720s
7240s
7440s
7263s
7463s
RATED CURRENT Ith
20A
40A
63A
5.4kW
16kW
8.6kW
26kW
13.6kW
41kW
1.1kW
4kW
2.2kW
7.5kW
4kW
11kW
2,800W
2,000W
7,000W
4,200W
10,000W
6,300W
VOLTAGE RATING (coil)
230V 50Hz
230V 50Hz
230V 50Hz
CABLE CAPACITY
6mm2 rigid
25mm2 rigid
25mm2 rigid
6220S:
84 x 18 x 66mm
7240S:
84 x 36 x 66mm
7463S:
84 x 54 x 66mm
6420S:
84 x 36 x 66mm
7263S:
84 x 36 x 66mm
6720S:
84 x 18 x 66mm
7440S:
84 x 54 x 66mm
HEATING
Single phase 230V
Three phase 400V
MOTORS
Single phase 230V
Three phase 400V
LIGHTING
Incandescent and
Halogen lamps:
Fluorescent Lamps:
(Electronic Ballast)
BS EN 61095
DIMENSIONS:
284
mkelectric.co.uk
(including half module blank)
Bell
Transformer
TWO MODULE
5711s
CIRCUIT PROTECTION
Sentry
Technical Hotline
+44 (0)1268 563720
Time Switches
DIGITAL
ONE CHANNEL
TWO MODULE
DIGITAL
ONE CHANNEL
ONE MODULE
SYNCHRONOUS
THREE MODULE
QUARTZ
STABILISED
THREE MODULE
SYNCHRONOUS
ONE MODULE
5707s
5824s
5833s
5731s
5733s
5732s
5824s1
5833s1
5731s1
5733s1
5732s1
Suitable for DIN rail
mounting in Sentry
Consumer Units and
two or four module
enclosures.
Power reserve 150 hours
VOLTAGE RATING:
220-240Va.c. 50-60Hz
CURRENT RATING:
Resistive load 16A
Inductive load 4A
Tungsten lamps 6A
(1350W)
Fluorescent lamps
1350W
DIMENSIONS:
85 x 54 x 68mm
CABLE CAPACITY:
2 x 2.5mm2 or 4 x
1.5mm2
EN 60730-2-7:1993
Suitable for DIN rail
mounting in Sentry
Consumer Units and
two or four module
enclosures
VOLTAGE RATING:
240V 50Hz
CURRENT RATING:
Resistive load 16A
Inductive load 4A
Tungsten lamps 6A
(1350W)
Fluorescent lamps 1350W
DIMENSIONS:
90 x 18 x 68mm
CABLE CAPACITY:
2 x 2.5mm2 or 4 x
1.5mm2
EN 60730-2-7:1993
Provides 50
programming selections.
Freely selectable day
grouping facility. Manual
override, winter/summer
time adjustment, holiday
programme and random
generator are standard
facilities.
Power reserve of 150
hours.
Suitable for DIN rail
mounting in Sentry
Consumer Units and
two or four module
enclosures
VOLTAGE RATING:
240V 50/60Hz
CURRENT RATING:
Resistive load 16A
Inductive load 2.5A
Tungsten lamps 5A
(1000W)
Fluorescent lamps
1000W
DIMENSIONS:
90 x 18 x 74mm
CABLE CAPACITY:
2 x 2.5mm2 or 4 x
1.5mm2
EN 60730-2-7:1993
Pre-programmed with
UK time and automatic
summer/winter
adjustment.
Provides 50
programming selections.
Freely selectable day
grouping facility. Manual
override, winter/summer
time adjustment.
Power reserve of 3 years.
Suitable for DIN-rail
mounting in Sentry
Consumer Units and
two or four module
enclosures.
VOLTAGE RATING:
240V 50/60Hz
CURRENT RATING:
Resistive load 16A
Inductive load 2.5A
Tungsten lamps 5A
(1000W)
Fluorescent lamps 1000W
DIMENSIONS:
85 x 36 x 68mm
CABLE CAPACITY:
2 x 2.5mm2 or 4 x
1.5mm2
EN 60730-2-7:1993
DIGITAL
TWO CHANNEL
TWO MODULE
5724s
5711s1
RATING 1A AT 8V
PRIMARY 220 – 240V A.C.50HZ
Suitable for installation in
Sentry Consumer Units
and two or four module
enclosures.
NOTE:
When installed in a
consumer unit, ensure
that output cables
inside the enclosures
are suitable for a 230V
environment, either by
sleeving the bell wire to
BS 2848 or using 230V
cable.
Complete with terminal
covers. Also suitable for
surface mounting.
DIMENSIONS:
88 x 36 x 67mm
CABLE CAPACITY:
1 x 2.5mm2
EN 61558-2-8
5707s1
7 DAY DIAL
MIN SETTING 3
HOURS
5724s1
24 HOUR DIAL
MIN SETTING 30
MINUTES
Suitable for DIN rail
mounting in Sentry
Consumer Units or four
module enclosures.
VOLTAGE RATING:
220-240Va.c. 50Hz
CURRENT RATING:
Resistive load 16A
Inductive load 4A
Tungsten lamps 6A
(1350W)
Fluorescent lamps 1350W
DIMENSIONS:
85 x 54 x 68mm
CABLE CAPACITY:
2 x 2.5mm2 or
4 x 1.5mm2
24 HOUR DIAL
MIN SETTING 30
MINUTES
24 HOUR DIAL
MIN SETTING 30
MINUTES
24 HOUR/7 DAY
DISPLAY
MIN SETTING 1
MINUTE
Pre-programmed with
UK time and automatic
summer/winter
adjustment.
Provides 50
programming selections.
Freely selectable day
grouping facility. Manual
override, winter/summer
time adjustment.
Power reserve of 3 years.
Suitable for DIN-rail
mounting in Sentry
Consumer Units and
two or four module
enclosures.
VOLTAGE RATING:
240V 50/60Hz
CURRENT RATING:
Resistive load 16A
Inductive load 2.5A
Tungsten lamps 5A
(1000W)
Fluorescent lamps
1000W
DIMENSIONS:
85 x 36 x 68mm
CABLE CAPACITY:
2 x 2.5mm2 or 4 x
1.5mm2
EN 60730-2-7:1993
24 HOUR DIAL
MIN SETTING 1
MINUTE
24 HOUR/7 DAY
DISPLAY
MIN SETTING 1
MINUTE
MK Electric Catalogue
285
CIRCUIT PROTECTION
Sentry
Time
Delay
Switches
mkelectric.co.uk
Consumer
Unit Cable Kits
Accessories
ONE MODULE
PUSH LEVER
UP TO
SWITCH ON
RCBO
TEST
BUTTON
PUSH LEVER
UP TO
SWITCH ON
10
11
12
13
14
15
16
18
19
20
21
22
23
24
2
14
RCD
PROTECTED
CIRCUITS
RCD
PROTECTED
CIRCUITS
TEST QUARTERLY
TEST QUARTERLY
3
4
5
6
17
18
7
8
19
20
9
10
SWITCH
1
2
3
9
17
4
5
10
11
12
13
18
19
20
21
RCD
PROTECTED
CIRCUITS
1
2
14
(Cut as required)
12
13
22
23
24
15
U1
16
U2
SOCKETS
GROUND
FLOOR
SOCKETS
FIRST
FLOOR
K8041s
K5545sMAG
24
TEST QUARTERLY
4
5
6
17
18
7
8
19
20
9
10
21
LIGHTS
OUTSIDE
RING
CIRCUIT
KITCHEN
RING
CIRCUIT
SECURITY
OUT
ALARM
BUILDING
220-250V 50Hz a.c.
220-250V 50Hz a.c.
SHOWER
SHOWER
SECURITY
ALARM
RATED CURRENT
MUST NOT EXCEED
63A MAX
RATED CURRENT
MUST NOT EXCEED
100A MAX
SMOKE
ALARM
CLEAN
EARTH
DOOR
BELL
4 module unit
CENTRAL
HEATING
FRIDGE
COOKER
COMPUTER
SMOKE
ALARM
LIGHTS
KITCHEN
SOCKETS
LIGHTS
GARAGE
SOCKETS
GARAGE
LIGHTS
ALL MAIN SWITCHES
MUST BE SWITCHED
OFF TO COMPLETELY
DISCONNECT THE UNIT
FROM THE SUPPLY
DISCONNECT THE
MAINS SUPPLY
BEFORE REMOVING
THIS COVER
OFF
MK SENTRY
CONSUMER UNIT
TO BS EN 60439-3
12
13
22
23
24
15
U1
16
U2
U3
H Main Switches Warning Labels
ON
IMPORTANT
SOCKETS
LIGHTS
SECOND
FLOOR
RING
CIRCUIT
SECOND
FLOOR
RING
CIRCUIT
FIRST
FLOOR
WATER
HEATER
SOCKETS
WARNING
SOCKETS
SECOND
FLOOR
LIGHTS
GROUND
FLOOR
RING
CIRCUIT
GROUND
FLOOR
WATER
HEATER
(Cut as required)
11
ON
STORAGE STORAGE
HEATER
HEATER
LIGHTS
BASEMENT
RING
CIRCUIT
BASEMENT
FREEZER
LIGHTS
FIRST
FLOOR
21
H Main Switches Warning Labels
OFF
MK SENTRY
CONSUMER UNIT
TO BS EN 60439-3
WARNING
DISCONNECT THE
MAINS SUPPLY
BEFORE REMOVING
THIS COVER
SOCKETS
BASEMENT
SOCKETS
GROUND
FLOOR
SOCKETS
FIRST
FLOOR
LIGHTS
OUTSIDE
RING
CIRCUIT
KITCHEN
RING
CIRCUIT
SECURITY
OUT
ALARM
BUILDING
220-250V 50Hz a.c.
220-250V 50Hz a.c.
SHOWER
SHOWER
SECURITY
ALARM
RATED CURRENT
MUST NOT EXCEED
63A MAX
RATED CURRENT
MUST NOT EXCEED
100A MAX
SMOKE
ALARM
CLEAN
EARTH
DOOR
BELL
4 module unit
CENTRAL
HEATING
FRIDGE
COOKER
COMPUTER
SMOKE
ALARM
K5597s
LIGHTS
KITCHEN
SOCKETS
LIGHTS
GARAGE
SOCKETS
IMPORTANT
SOCKETS
LIGHTS
SECOND
FLOOR
RING
CIRCUIT
SECOND
FLOOR
RING
CIRCUIT
FIRST
FLOOR
WATER
HEATER
SOCKETS
WARNING
SOCKETS
SECOND
FLOOR
LIGHTS
GROUND
FLOOR
RING
CIRCUIT
GROUND
FLOOR
WATER
HEATER
LIGHTS
FIRST
FLOOR
ON
STORAGE STORAGE
HEATER
HEATER
LIGHTS
BASEMENT
RING
CIRCUIT
BASEMENT
FREEZER
8, 12, 16 & 21 module units
This proof has been printed on a low resolution colour proofer. Colours may vary from final print.
Liability cannot be accepted by PPL for errors or omissions once the proof and job specification has been approved.
5650s
8
16
23
RCD
PROTECTED
CIRCUITS
3
G Individual Circuit Labels
5544s
7
15
22
TEST QUARTERLY
F Circuit ID Labels
U3
RCD
TIME DELAYED
11
ON
5562s
6
14
RCD
PROTECTED
CIRCUITS
TEST QUARTERLY
MAIN
SWITCH
F Circuit ID Labels
SOCKETS
BASEMENT
B RCD 'TEST' Label
Fit to prominent position on or near
Consumer Unit.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
RCD
TIME DELAYED
1
RCBO
TEST
BUTTON
RCD
ADDITIONAL INFORMATION
8
TEST QUARTERLY
PUSH LEVER
UP TO
SWITCH ON
PUSH LEVER
UP TO
SWITCH ON
Pantone
355
CIRCUIT
NUMBER
7
RCD
PROTECTED
CIRCUITS
Pantone
Black
E Additional Information Label
6
A RESETTING INSTRUCTION LABEL
ADDITIONAL INFORMATION
5
CIRCUIT
NUMBER
4
MAIN
Mid-Trip
Off
Pantone
102
Pantone
Blue??
If any device still switches off (or if the RCD cannot be switched
on with all MCB's switched off) then call a qualified electrician,
or for general guidance, MK Technical Services on 01268 563720.
3
E Additional Information Label
9
17
TEST BUTTON
On
MCB
RCD
• Reset the lever to the off position, if necessary.
• Push the lever up, to switch on.
• If the RCD trips again, switch off
all MCB's & switch on the RCD.
• Switch each MCB on, one at a time.
the RCD will switch off when the
faulty circuit is reconnected.
Pantone
485
This installation, or part of it, is
protected by a device which
automatically switches off the supply
if an earth fault develops.
Test quarterly by pressing the button
marked 'T' or 'Test'. The device
should switch off the supply and
should then be switched on to restore
the supply.
If the device does not switch off the
supply when the button is pressed,
seek expert advice.
RESETTING INSTRUCTIONS
If a device switches 'OFF' in the event
of a fault, take the following action:
MCB / RCBO
• Check each appliance connected to
that device and remove if faulty.
• Push the lever up, to switch on.
• Under fault detection the MCB will trip to a
mid-"trip" position.
Reset MCB by switching "off", then "on".
Reset RCBO by switching to "on".
B RCD 'TEST' Label
Fit to prominent position on or near
Consumer Unit.
RCD
1 2 3 4 5 6 7 8 9 10 11 12 13 14
2
MK Electrics
22852
F641
25.03.08
v. 2
228.6 x 320
SENTRY CONSUMER UNIT - LABEL SHEET
Please leave any unused labels with the consumer
If any device still switches off (or if the RCD cannot be switched
on with all MCB's switched off) then call a qualified electrician,
or for general guidance, MK Technical Services on 01268 563720.
A RESETTING INSTRUCTION LABEL
1
Ref:
Ono:
Our Ref:
Date:
Version:
Size:
WARNING
Pantone
355
GARAGE
LIGHTS
DISCONNECT THE
MAINS SUPPLY
BEFORE REMOVING
THIS COVER
ALL MAIN SWITCHES
MUST BE SWITCHED
OFF TO COMPLETELY
DISCONNECT THE UNIT
FROM THE SUPPLY
OFF
MK SENTRY
CONSUMER UNIT
TO BS EN 60439-3
OFF
MK SENTRY
CONSUMER UNIT
TO BS EN 60439-3
WARNING
DISCONNECT THE
MAINS SUPPLY
BEFORE REMOVING
THIS COVER
8, 12, 16 & 21 module units
G Individual Circuit Labels
This proof has been printed on a low resolution colour proofer. Colours may vary from final print.
Liability cannot be accepted by PPL for errors or omissions once the proof and job specification has been approved.
K5599s
K5563s
K6061SMET
K5511s
5650s1
DELAY RANGE
1 - 7 MINUTES (APPROX)
Suitable for installation in Sentry
Consumer Units and two or four
module enclosures. Offers time
delay control for complete circuits
of either tungsten or fluorescent
lighting with any number of standard
push switches. It can also be used
to control fans in bathrooms without
a window. Delay setting can be
over-ridden by setting to ‘Perm-on’
mode, or by fitting a remote overriding
switch. Switch has a switching
capacity of 16A Resistive loads (upf)
Fluorescent lamps uncompensated
Series compensated 1300W
Parallel compensated 480W
CFLS 100W Max. Maximum of 9 units
can be connected
Incandescent lamps 2000W
Neon glow lamp load (locating lamp
for Push Switch) 50mA max
VOLTAGE RATING:
230V 50Hz
DIMENSIONS:
84 x 18 x 70mm
CABLE CAPACITY:
1 x 4mm2or 2 x 1.5mm2
286
mkelectric.co.uk
K5565s
K5593s
KAX26s
K6062SMET
K5563s5
5562s1
5544s5
K5597s5
SPLIT-LOAD KIT
CONSISTS OF 3 CABLES
(2 NEUTRAL AND 1 LIVE) FOR
USE WHEN ASSEMBLING A
SPLIT LOAD ARRANGEMENT
K5565s5
MULTI-INCOMER KIT
CONSISTS OF A BLUE FLEXIBLE
CABLE WITH
PRE-FITTED TERMINAL FOR
THE NEUTRAL RETURN FROM
SWITCH OR RCD TO SECOND
OR THIRD NEUTRAL BAR
K5568s5
17TH EDITION CABLE KIT
FOR SWITCH AND TWIN RCD
ARRANGEMENT
K5567s5
A&D CABLE KIT FOR
SWITCH PLUS TRIPLE RCD
ARRANGEMENT
K5563S
For use when assembling split-load
arrangement.
K5565S
For use when assembling a consumer
unit in a multi-incomer arrangement
with separate supply to each incomer.
These kits must be used to ensure
compliance with BS EN 60439-3
EXTENSION TERMINAL FOR
USE WHEN ASSEMBLING
A CONSUMER UNIT AS A
DISTRIBUTION BOARD.
ENABLES DIRECT CONNECTION
OF CABLES TO THE NEUTRAL
BAR. CONSISTS OF A 25MM2
CAPACITY TERMINAL WITH
CLAMP SCREW
K8041s10
LOCKING DEVICE FOR USE
WHEN LOCKING A SENTRY
MCB, RCBO, RCD OR SWITCH
DISCONNECTOR IN EITHER THE
ON OR OFF POSITION
K5593s
BARREL LOCK AND KEY KIT
SUITABLE FOR SECURING ‘K’
SERIES SENTRY CONSUMER
UNIT LIDS.
ONLY SUITABLE FOR HYBRID
AND INSULATED CONSUMER
UNITS
1
MCB BLANK – GREY DESIGNED
TO FILL UNUSED MODULES
IN SENTRY CONSUMER UNITS
AND SMALL ENCLOSURES.
DIN-RAIL MOUNTED
K5545sMAG10
COVER MOUNTED BLANK FOR
FILLING SPACES IN THE ‘K’
SERIES SENTRY CONSUMER
UNIT COVER, WHERE THERE
ARE UNUSED MODULES
K5511s1
BUSBAR 11 MODULE
K5590s1
BUSBAR 20 MODULE
KAX26s10
BUSBAR COVER
SUITABLE FOR INSULATING
THE BUSBARS K5511S AND
K5590S 20 MODULE.
ONLY SUITABLE FOR HYBRID
AND INSULATED CONSUMER
UNITS
ENSURE ALL TERMINAL
SCREWS ARE FULLY
TIGHTENED BEFORE
FITTING FRONT COVER
Mid-Trip
Off
Pantone
Black
C Busbar Shield Warning Label
(Factory fitted)
TEST BUTTON
On
MCB
RCD
• Reset the lever to the off position, if necessary.
• Push the lever up, to switch on.
• If the RCD trips again, switch off
all MCB's & switch on the RCD.
• Switch each MCB on, one at a time.
the RCD will switch off when the
faulty circuit is reconnected.
Pantone
102
Pantone
Blue??
WARNING
RESETTING INSTRUCTIONS
If a device switches 'OFF' in the event
of a fault, take the following action:
MCB / RCBO
• Check each appliance connected to
that device and remove if faulty.
• Push the lever up, to switch on.
• Under fault detection the MCB will trip to a
mid-"trip" position.
Reset MCB by switching "off", then "on".
Reset RCBO by switching to "on".
Pantone
485
This installation, or part of it, is
protected by a device which
automatically switches off the supply
if an earth fault develops.
Test quarterly by pressing the button
marked 'T' or 'Test'. The device
should switch off the supply and
should then be switched on to restore
the supply.
If the device does not switch off the
supply when the button is pressed,
seek expert advice.
ENSURE ALL TERMINAL
SCREWS ARE FULLY
TIGHTENED BEFORE
FITTING FRONT COVER
MK Electrics
22852
F641
25.03.08
v. 2
228.6 x 320
SENTRY CONSUMER UNIT - LABEL SHEET
Please leave any unused labels with the consumer
C Busbar Shield Warning Label
(Factory fitted)
Ref:
Ono:
Our Ref:
Date:
Version:
Size:
CONSUMER UNIT LABELS
ADDITIONAL PRINTED
AND BLANK LABELS, FOR
IDENTIFYING DEVICES AND
CIRCUITS ON DUAL & TRIPLE
RCD BOARDS
K5599s5
CONSUMER UNIT LABELS
ADDITIONAL PRINTED
AND BLANK LABELS, FOR
IDENTIFYING DEVICES AND
CIRCUITS ON SINGLE RCD
BOARDS
K5804sD1MAG
K5808sD1MAG
K5812sD1MAG
K5816sD1MAG
K5821sD1MAG
REPLACEMENT PLASTIC
FRONT COVERS
K6060SMET1
16 WAY METAL CONSUMER
UNIT SURFACE MOUNTING KIT
K6061SMET1
12 WAY METAL CONSUMER
UNIT STACKING KIT
K6062SMET1
16 WAY METAL CONSUMER
UNIT STACKING KIT
ASPECT DOUBLE SOCKET – BESPOKE FINISH
Available on a worldwide basis, the MK Design
Service is supported by a dedicated team to ensure
the seamless delivery of your chosen products.
To find out more visit www.mkelectric.co.uk
MK Electric Catalogue
287
PRODUCT
APPLICATION
PRODUCT APPLICATION