eco-SPRAY - preeflow
Transcription
eco-SPRAY - preeflow
Micro spray system Commissioning and maintenance instructions eco-SPRAY Artikelnummer 21504 Druck 22.1.16 eco-SPRAY Commissioning and maintenance instructions Contents 1 2 3 4 5 These instructions 5 The dispenser 5 2.1 2.2 6 6 Safety 7 Connection options 7 Initial commissioning 8 5.1 5.2 5.3 6 7 8 9 10 11 Copyright © Spray head combinations Retrofitting the spray head Inserting the stator Making the electrical connection Supplying and bleeding the medium 8 10 11 Operation 12 Cleaning 12 Spare parts 15 Maintenance 17 9.1 9.2 17 17 Changing the stator Troubleshooting Disposal 18 Technical specifications 18 Version 1.0 3 / 19 eco-SPRAY Commissioning and maintenance instructions 4 / 19 Version 1.0 Copyright © eco-SPRAY Commissioning and maintenance instructions 1 These instructions Dear customer, These instructions form part of the operating and maintenance instructions for the dosing system eco-CONTROL EC200. The operating and maintenance instructions must have been read and understood in full before commissioning or carrying out maintenance work on the eco-SPRAY. 2 The dispenser The dispenser is supplied with these components and accessories: B A C D E F H G Fig. 1 A Dispenser with drive B Assembly aid C Nozzle mounting tool D Stator E 3x precision dosing needles* F 3x air caps* G Screwdriver H Allen wrench *1 unit pre-mounted Copyright © Version 1.0 5 / 19 eco-SPRAY Commissioning and maintenance instructions Spray head combinations We recommend selecting the air cap (B) with the corresponding precision dosing needle (A) depending on the medium viscosity. A 0,3 0,2 1,45 0,5 B 1,7 ig h The appropriate combination must be selected and tested separately for each application (viscosity, dosing quantity/ time and temperature). Vi sc os ity Lo w 2.1 H 2,0 Fig. 2 2.2 Retrofitting the spray head • Undo the union ring (2) • Remove the air cap (29). The seal (30) remains either in the spray head or stuck to the air cap (29) • Carefully attach the nozzle mounting tool (31) to the precision dosing needle (28), unscrew the precision dosing needle and replace it with another one • Attach an air cap (29) and re-tighten the union ring (2) 31 10 3 30 28 29 2 Fig. 3 6 / 19 Version 1.0 Copyright © eco-SPRAY Commissioning and maintenance instructions 3 Safety All instructions in the Safety section of the maintenance and operating instructions for the dosing system must be complied with and implemented. 4 Connection options Supply of the medium from a cartridge (A) or a bottle (B). D Power supply drive unit E Controlled compressed air F Heating (optional) G Dosing control H Compressed air control J Compressed air connection K Power supply L External control (start/stop) F D E B A L J G M H L K Fig. 4 Copyright © Version 1.0 7 / 19 eco-SPRAY Commissioning and maintenance instructions 5 Initial commissioning Dispenser Do not switch on until medium has been delivered. Otherwise there is a risk of damage to the equipment. Even a brief period of dry running can lead to the stator being destroyed. 5.1 Inserting the stator • Switch off the dosing control • Unplug the power supply from the drive unit • Undo the union ring (2) • Remove the air cap (29). The seal (30) remains either in the spray head or stuck to the air cap (29) • Carefully attach the nozzle mounting tool (31) to the precision dosing needle (28) and unscrew the precision dosing needle • Unscrew the screws (8) and remove the air housing 31 10 30 3 8 28 29 2 Fig. 5 8 / 19 Version 1.0 Copyright © eco-SPRAY Commissioning and maintenance instructions • Unscrew the screws (18) and remove the end piece (27) • Loosen the grub screws (14) by approximately three rotations and remove the drive unit (11) from the pump housing (10) • Attach the star-shaped coupling (5) to the assembly aid (6) 14 5 10 11 14 6 27 18 Fig. 6 • Dock the assembly aid (6) with the star-shaped coupling (5) on the dispenser housing (10) • Turn the stator (7) on the rotor (4) – which is wet with medium – until the dowel pin (8) begins to dip into the keyway (9) • Lightly press the stator in the direction of the dispenser housing (10) and turn the assembly aid (6) in the direction of the arrow until the stator has been guided into the dispenser housing 6 5 10 Medium 9 7 8 4 Fig. 7 Copyright © Version 1.0 9 / 19 eco-SPRAY Commissioning and maintenance instructions • Uncouple the assembly aid and re-attach the star-shaped coupling (5) to the drive unit (11). • Insert the drive unit (11) into the dispenser housing (10). Ensure that the anti-rotation lock (A) is positioned within the designated recess in the dispenser housing (10) • Tighten both grub screws (14) and secure the end piece (27) with the screws (18). Ensure that the anti-rotation lock (B) is positioned within the designated recess in the end piece (27) 14 10 11 5 A 27 18 14 B Fig. 8 • Attach the air housing and precision dosing needle. Follow the steps in the reverse order to the process shown in Fig. 5 5.2 Making the electrical connection Connect the eco-CONTROL EC200 dosing control and eco-CONTROL SC1200 control unit according to their respective operating and maintenance instructions. 10 / 19 Version 1.0 Copyright © eco-SPRAY Commissioning and maintenance instructions 5.3 Supplying and bleeding the medium Follow the safety stipulations and instructions of the manufacturer of the medium to be used to fill the unit. If applicable, use the required protective equipment. If the medium is being conveyed for the first time, there is a danger from medium spurting out. Air bubbles can cause uncontrollable spurting out. Ensure that you stand back a safe distance. • Connect the tank (supply line, cartridge) of the medium to the dispenser medium (A) • Connect the transparent hose (2) (with an inner diameter of 4 mm) to the bleed valve (23) • Pressurise the medium 23 • Slowly open the bleed valve (23) by approximately half a turn until the medium escapes without bubbles 2 A • Close the bleed valve and remove the hose Fig. 9 Tip Ensure the hose in use is sufficiently long (approx. 20 cm) and capable of holding the entire medium required for the bleeding process. You can then dispose of this conveniently at the end of the process. Copyright © Version 1.0 11 / 19 eco-SPRAY Commissioning and maintenance instructions 6 Operation Operation takes place according to the operating and maintenance instructions using the eco-CONTROL EC200 dosing control and eco-CONTROL SC1200 control unit. 7 Cleaning Follow the safety stipulations and instructions of the manufacturer of the medium to be used to fill the unit. If applicable, use the required protective equipment. If the medium is being conveyed for the first time, there is a danger from medium spurting out. Air bubbles can cause uncontrollable spurting out. Ensure that you stand back a safe distance. • Switch off and disconnect the power supply from the drive unit and remove the medium supply • Dismantle the dispenser as outlined in section 5.1, Fig. 5 and Fig. 6 • Unscrew the valve attachment (32) for the bleed valve (23) 10 32 23 Fig. 10 12 / 19 Version 1.0 Copyright © eco-SPRAY Commissioning and maintenance instructions • Dock the assembly aid (6) with the star-shaped coupling (5) on the dispenser housing (10) • Turn the assembly aid (6) in the direction of the arrow. The stator (7) will be pushed so far out of the dispenser housing (10) by the rotor assembly (4) that the dowel pin (8) is no longer in the groove (9) • Uncouple the assembly aid (6) from the dispenser housing (10) and completely remove the stator (7) from the rotor assembly (4) by turning and pulling 6 10 5 9 7 8 4 Fig. 11 • Unscrew four screws (26) and pull off the pump housing (19) from the bearing housing (13) 26 19 26 13 23 Fig. 12 Copyright © Version 1.0 13 / 19 eco-SPRAY Commissioning and maintenance instructions • Unscrew two screws (4) and pull off the sealing kit with housing (25) from the bearing housing (13) 4 25 4 13 Fig. 13 Note Do not rinse out the bearing housing (13), as that could damage the bearings! Clean it with a cloth and brush. Assembly Assembly takes place in reverse order to the process described above. 14 / 19 Version 1.0 Copyright © eco-SPRAY Commissioning and maintenance instructions 8 Spare parts 5 9 26 4 11 30 14 13 24 25 21 14 33 19 23 34 7 27 6 18 30 22 3 8 28 29 2 31 Fig. 14 Copyright © Version 1.0 15 / 19 eco-SPRAY Commissioning and maintenance instructions Item Part No. x Item name 21500 Combi package comprising part no.: 21448, 20120 ,21499 21448 eco-SPRAY dispenser 20120 eco-CONTROL EC200-K dosing control, compl. 21499 eco-CONTROL SC1200 control unit 21447 eco-SPRAY dosing unit, compl. 2 21374 eco-SPRAY union ring A2 3 21373 Air housing spray A2 4 20250 5 20050 6 20108 7 20001 8 20828 M3 Allen screw 9 20784 Connection cable for drive unit 300/450/600/700 M3 Allen screw x Star-shaped coupling Elastomer Assembly aid / tool Aluminium x Stator, compl. VisChem 11 21449 x eco-SPRAY drive unit, compl. 13 21507 x Bearing housing with eco-SPRAY rotor assembly, compl. 14 20029 Set screw 18 20828 M3 Allen screw 19 21501 21 20011 x R 13 O-ring FKM x R 15 O-ring FKM eco-SPRAY pump housing A2 22 20084 23 21464 24 20007 x R 16 O-ring 25 21508 x Sealing chamber with eco-SPRAY housing 26 20585 M3 Allen screw 27 21411 eco-SPRAY end piece 28 21455 x Conical precision dosing needle ø 0.2 mm A2 21454 x Conical precision dosing needle ø 0.3 mm A2 21453 x Conical precision dosing needle ø 0.5 mm 29 16 / 19 Material 21378 Bleed valve with M5 nipple, shortened FKM eco-SPRAY air cap ø 1.45 A2 A2 A2 21379 eco-SPRAY air cap ø 1.7 A2 21380 eco-SPRAY air cap ø 2.0 A2 30 21460 31 21291 x R 11 O-ring Nozzle mounting tool for precision nozzles FKM 20204 Electronic screwdriver, 2.5 Version 1.0 A2 Copyright © eco-SPRAY Commissioning and maintenance instructions 20203 Allen wrench, 1.5 20366 3m6 dowel pin 34 120308 Push-in L fitting 33 21502 Blanking plate for eco-SPRAY heating assembly A2 x = recommended spare parts and wearing parts Other precision dosing needles and air caps available on request 9 9.1 Maintenance Changing the stator • Remove the defective stator (see description for Fig. 11 on page 13) • Install the new stator (see “Assembly” in section 7, Cleaning,, page 12) 9.2 Troubleshooting Fault No or too little medium conveyed Possible cause Action Blockage in precision dosing needle Clean/replace the needle Medium hardened Clean Dispenser Precision dosing needle and/or Use another precision dosing air cap not suitable for the needle profile and/or air cap. medium, output and/or air Change the speed / flow rate pressure Stator swollen Replace the stator Inadequate supply of medium Supply the medium, check the hose, check the primary pressure and increase it if necessary Motor not connected Connect the motor Sucking back not set correctly Set the sucking back Dripping / running on of the Air bubbles in the medium medium Medium compressible Follow-up spray time too short Copyright © Version 1.0 Bleed the medium Degas the medium Increase follow-up spray time 17 / 19 eco-SPRAY Commissioning and maintenance instructions 10 Disposal Dispose of the Dispenser in an environmentally safe way. All materials and products left in containers must be treated in accordance with the appropriate recycling requirements. Electrical components must not be disposed of together with household waste. They must be taken to the collection points provided for this purpose. 2002/96/EC – EU Directive on waste electrical and electronic equipment (WEEE) 11 Technical specifications General Dimensions Weight Heating Operating conditions Storage conditions Repeat accuracy Maximum dosing pressure Self-sealing a) Parts touched by medium Seals Motor General Dosing volume, approx. Length 228 mm, ø 35 mm Approx. 510 g Optional +10°C to +40°C (ambient temperature), air pressure 1 bar Dry / dust free -10°C to +40°C > 99% 16 to 20 bar Approx. 2 bar (reference medium approx. 10 mPas at 20°C) HD-POM / stainless steel / PEEK High-molecular PE, VisChem 18 to 24 V DC, incremental encoder, planetary gear 0,05 ml/rotation Volume flow b) Medium Connection Temperature Pressure Viscosity 18 / 19 0.5 to 6.0 ml/min 1/8"cylindrical Whitworth pipe thread DIN/ISO 228 +10°C to +40°C 0 bar, with self-levelling liquid/ max. 6 bar Low to high viscosity Version 1.0 Copyright © eco-SPRAY Commissioning and maintenance instructions Spray head Connection Hose connection, outer diameter 4 mm (M5 process connection) 0.1 to 6 bar Dust free, oil free, dehumidified Over 100 cycles/min Nozzle diameter: 0.2 mm, 0.3 mm, 0.5 mm Circular jet (variable) 15 to 30° 50 µl Pressure of the atomiser air Quality of the atomiser air Switching frequency Precision dosing needle Spray pattern Spray angle Minimum spray amount Spray accuracy c) Spray amount ±1% a) Max. dosing pressure and self-sealing decrease with decreasing viscosity and increase with increasing viscosity. Consult manufacturer b) Volume flow dependent on viscosity and primary pressure c) Volumetric dosing as absolute deviation relative to one dispenser rotation. Depending on the viscosity of the dosing medium Materials used Dispenserhousing, spray head A2 Shaft sealing rings Z80 Motor housing Anodized aluminium O-rings FKM Screws, washers, etc. A2 Drive shaft, rotor A4 Stator elastomer, flexible shaft covering VisChem lastpage Copyright © Version 1.0 19 / 19 info@preeflow.com www.preeflow.com