Quick Guide and Schematics 230 Bay Reef
Transcription
Quick Guide and Schematics 230 Bay Reef
230 Bay Reef Quick Guide and Schematics FuelSystem The230BRisequippedwithasingle,80Gallon,pressurizedfueltank.ThetankisofPolyethlene constructionandisinsulatedwithfoamduring theconstructionoftheboat.Thetankislocatedoncenterlinebetweenthelivewell andaftendoftheconsole.Thereisasendingunitinstalledin thetank.Inspectionportsinthedeckandheadcompartmentprovideaccesstotankfittings. Thereisafuelpickupsinstalledinthetank.Thepickupincorporatesashutoffvalvealongwithananti‐siphonvalvethancanbeaccessedthrough theindeckinspectionplateundertheleaningpost. Thereisanondeckfuelfilllocatedontheportsideoftheboat,justforwardoftheconsole.Accesstothefillisprovided throughaninspection port.ThetankventsthroughanEPACarbonCanister,locatedintheanchorlocker,whichthanventsoverboardthroughavent fittingonthe starboardsideofthehull.Accesstotheventisprovidedthroughaninspectionport.Itisrecommendedthattheseconnectionsbeinspected annually. The230BRwillcomepre‐riggedfromthefactorywithanenginematchedFuelWaterSeparator.Thefuelwaterseparatorisinstalledinthebilge andaccessedthroughthebilgeaccesshatchlocatedintheenginepod.TheFuelWaterseparatorshouldbecheckedperiodicallytoensurethefuel isfreeofwater.Fuelshouldbedisposedofinanapprovedwastecollectiondevicewhenservicing/replacing.Thefiltermustbefilledwithfuel afterservicing/replacingtheminordertoprimetheengine. Aprimerbulbforeachengineislocatedintheenginepod.Itisusedtoprimetheengineandsystembeforestartingtheengines.Thisshouldbe doneafterserviceorafterlongperiodsofdowntimefortheboat. Allcomponentsofthe230BRFuelSystemareapprovedforusewithethanolblendedfuelsupto10%.E85fuelshouldneverbeused.KeyWest recommendsusingnonethanolfuelswheneverpossibletoreducetheriskofmoistureretentioninthefuelsystem,especiallyinareasofhigh heat/humidity. Whenrefuelingthe230BR,whetherontraileroratamarina,thepressurizedsystemwillpreventoverfilling.Duringfueling,checktoensureairis escapingfromthetankventonthestarboardside.Anyblockageofthevent,ventlineand/ororificelinewillprematurelytriggertheshutoffon thefuelnozzleandwillpreventyoufromfillingthetankcompletely. DuetotheemissionrequirementsoftheEPA,certifiedfueltanksandsystemswillnotfilltothetopofthetank.Instead, therewillbeaullage in thetop10%ofthetank.Thespecifiedcapacityofthetank(100Gallons)accountsforthisullage,howeveritisimportanttonotethatfuelsenders donotaccountforthis.Therefore,fillingthetankto100Gallonswillnotindicate“Full”onthegauge.Whenusingyourboat,itisagoodpractice tokeepalogandarunningcountofhowmuchfuelyou’veused.Donotrelyonthefuelgaugeexclusivelyasvariationswill occur. RawWaterSystem(Livewells) The230BRfeaturesarawwatersystemfortheaftandforwardlivewells,optionalleaningpostlivewell,optionalrawwaterwashdown systemand optionalaftlivewell recirculatingsystem. RawWaterSupply The230BRfeaturesatwohighspeedventuri pickupsforrawwaterintake.Thepickupsincorporateaseacock.Beforeusingtheboat,itisimportantto notethelocationoftheseacocksandthemeanstoachieveaccesstothem.Intheeventofaruptureinarawwaterlineorpumpthatallowsunrestricted flowofwaterintothebilge,shuttingtheseacockwillbecritical.Seacocksshouldbecheckedperiodicallyandthevalvesmovedtoverifyoperationand unrestrictedmovement.Ifproblemsarefound,theyshouldbeaddressedimmediatelybyyourdealer. ForwardandAftLivewell FillSystem Therearetwo800GPHlivewell pump.Theyaredirectlymountedtotheseacocks.Theportpumpprovidesrawwatertotheforwardlivewell.The starboardpumpprovidesrawwatertheaftlivewell andtheoptionalleaningpostlivewell.Thepumpshaveanindependentswitchesandcircuit breakers(SeeElectricalSchematics).Tousethelivewells,itisimportanttocheckandverifytheseacocksareopen.Failuretoopentheseacocksmay resultinpumpfailureifthepumpisrundryforanextendedperiodoftime.Thelivewell pumpshaveapressureregulatorthatwillshutthepumpoffif thelivewell fillvalvesarenotopen.Iftraileringtheboatorusingtheboatafteranextendedperiodofdowntime,itwillbenecessarytoprimethe pumps.Beforeactivatingthepumps,makesurethelivewell fillvalvesareopenandthanswitchonthepumps.Whenthesystemisfreeofair,youcan eithershutthefillvalveinthelivewells orshutoffthepumps.Itisimportanttocheckthelivewell pumpsannuallyandperiodicallysprayit/themwitha corrosioninhibitor. AftLivewell RecirculatingPump(Optional) The230BRcanbeequippedwitharecirculatingpumpfortheaftlivewell.Arecirculatingpumpisapumpthatpullswaterfromthebottomofthe livewell,aeratesitandthanreturnsittothetopofthelivewell.Thenormallivewell systemdoesthis,howeveritiscontinuouslyreplacingwaterby drawingitfromtherawwaterintake.Indeeperwater,thisisthebestwaytokeepwaterfreshandcool.However,whenoperatinginshallowwater wherethewaterismuddyorsandy,therecirculatingpumpallowsyoutorecirculateandaeratecleanwatersothatyouarenotdrawingindirtywater thatcouldharmyourbait.Inthe230BR,therecirculatingpumpismounteddirectlytotheaftsideofthelivewell.Thereturnfromthepumpisinthe topaftcornerofthelivewell.Thepumpisan800GPHpumpandhasanindependentswitchandcircuitbreaker(SeeElectricalSchematic).Thepump willprimeitselfwheneverwaterisabovetheintakescreenofthepump.Tousethepump,activatetheswitch.Thereareno valvestoopen.Waterwill begincirculatingimmediatelyprovidedthereisenoughwaterinthelivewell.Neverrunthepumpwithoutasufficientamountofwaterinthelivewell. Runningthepumpdryforextendedperiodsoftimemaydamagethepumpresultinginfailure.Watershouldbeabovetheinletscreenwhenusingthe pump.Therecirculatingpumpcanberuninconjunctionwiththeaftlivewell pumptoprovideincreasedcirculationandaeration,howeveritisnot necessary. LeaningPostLivewell (Optional) Foranglerswhowantanadditionalandlargerlivewell,the230BRcanbeequippedwithaLivewell LeaningPost.TheLivewell LeaningPostprovides greatflexibilitytoanglers,especiallytournamentanglersbecauseitallowstheaftlivewell tobeusedasreleasewelliftheywish,capableofcirculating watereitherviathelivewell fillsystemand/ortheoptionalrecirculatingpump.Rawwatertothelivewell leaningpostissuppliedviathestarboard livewell pump.AT‐Connectorisinstalledsothatrawwatercanbeusedbyboththeaftandleaningpostlivewell.Thelivewell featuresafillvalve, identicaltotheforwardandaftlivewell.Thisallowsyoutofillandusetheaftlivewell,theleaningpostlivewell,orbothdependingonyourfishing needs.TousetheLivewell LeaningPost,engagetheaftlivewell pumpandopenthefillvalveinthelivewell. RawWaterSystem StandardRawWaterWashSystem The230BRisequippedwitharawwaterwashsystem.Thesystemusesthestarboardlivewell pumptoproviderawwatertotheprovidedwashdown hose.Pleasenotethoughthatusingthesystemdoesnotallowuseoftheaftlivewell.Tousethesystem,unscrewthelivewell fillvalveintheaftlivewell andthreadthehoseontotheinlet.Thelivewell pumpispressureregulatedsothatthepumpcanbelefton,evenwhennotusingthewashdown.If traileringtheboatorusingtheboatafteranextendedperiodofdowntime,itwillbenecessarytoprimethesystem.Before activatingtheaftlivewell pump,depressthenozzleonthewashdown hoseandthanswitchonthepump.Whenthesystemisfreeofairandasteadystreamofwateriscoming fromthehose,thesystemisbled. OptionalHighPressureWashdown system The230BRcanbeequippedwithanoptionalhighpressure,rawwaterwashdown system.Thesystemisfedbyapumpthatislocatedintheaftendof theporttransomdrystoragecompartment.Thepumpiscontrolledbyaswitchandcircuitbreaker(SeeElectricalSchematics).Waterissuppliedtothe pumpoffoftheaccessoryportontheportlivewell pump(lowerhoseconnectiononthelivewell pump).Usingtherawwaterwashdown doesnot requirethelivewell pumptobeonhowevertheportseacockmustbeopen.Failuretoopentheportseacockmayresultinpumpfailure/damageifthe pumpisrundryforanextendedperiodoftime.Therawwaterpumpfeaturesanin‐linestrainerforcollectinganydebristhatcoulddamagethepump. Thestrainershouldbecheckedbeforeusingthepump.Thestrainerfeaturesaclearcapforeasyinspection.Ifanydebrisisfound,removethestrainer screenbyuntwistingtheclearcapandcleanthescreen.Thepumpfeaturesabuiltinpressureregulatorthatwillshutthepumpoffwhenpressureis achievedinthesystem.Therawwaterwashdown faucetislocatedontheportsidesideunderthegunwhale cap,adjacenttotheportjumpseat.If traileringtheboatorusingtheboatafteranextendedperiodofdowntime,itwillbenecessarytoprimethewashdown pump.Beforeactivatingthe pump,openthewashdown faucetandthanswitchonthepump.Whenthesystemisfreeofair,youcaneitherclosethefaucetorshutoffthepump.Itis importanttocheckthewashdown pumpannuallyandperiodicallysprayitwithacorrosioninhibitor. SystemOperationandMaintainence Whenusinganyofthetwo/threerawwaterpumps,itisimportanttopayattentiontothewateryouareoperatingtheboatin. Operatingthepumpsin shallow/muddywaterorwaterwithhighamountsoffloatingdebrissuchasgrassortrashmayresultiningestionanddamagethepumps.Lossof pressureinpumpsmaybetheresultofcontainmentsblockingthethruhulls,bindingofthepumpsimpellor,cloggedstrainerbasketand/orblockagein lines.Whenoperatinginthecontaminatedwater,checkthesupplyofandqualityofwatertothelivewells orwashdown frequently.Anylossof pressureorflowshouldbeaddressedimmediatelytopreventdamage.Iffishingandinstalled,usetheaftlivewell recirculatingpumptocirculateand aeratethewatersothatyoucancontinuetofishwithfreshbaitwithoutworryofdamagingtherawwaterpumps. Fresh WaterSystem FreshWaterSupply Freshwaterisstoredina6gallontanklocatedundertheconsolefloor,directlybelowtheconsolecoolerbox.Accesstothetankisachievedthrougha hatchinsidetheconsole.Thetankfeaturesafillline,ventlineandsupplyline.Thesefittingsshouldbecheckedannually. Itiscriticalthatonlypotable waterbeusedinthetank.Failuretodosowillrequireoverhauloftheentirefreshwatersystem. FreshWaterFillandVent Thefreshwatertankisfilledfromafilldeckplatemarked“WATER”.Itislocatedonthestarboardsideoftheconsolecooler seat.Beforefillingthetank, verifythequalityofthewaterandmakesureareaaroundthefillisfreeofcontainmentsthatcouldenterthetank.Whilefilling,verifythetankisventing throughthetankventwhichislocatedonthefrontsideofconsoleseat.Anabsenceofairescapingfromtheventmayindicate ablockageorkinkinthe ventline.Thiswillresultinthetankfailingtofillallthewaywhichwillshowinwaterflowingoutofthefillwellbeforecomingoutofthevent.Itwill alsodiminishtheperformanceofthefreshwatersystemasablockedventwillcreateavacuuminthetankaswaterisused,therebyresultinginless watertothepump,continuouscyclingofthepumpandlossofwaterpressure.Thiscouldultimatelyresultindamagetothepump.Checktheventline periodicallytoensuretherearenokinksorblocks. Washdown Pump Thefreshwaterwashdown systemisfedbyapumpthatislocatedadjacenttothewatertank.Thepumpiscontrolledbyaswitchandcircuitbreaker (SeeElectricalSchematics).Waterissuppliedtothepumpfromthetankoutletlocatedonthebottomofthetankandisgravityfedfromtheweightof thewaterinthetank.Thisallowsall6gallonstobeused.Thefreshwaterpumpfeaturesanin‐linestrainerforcollectinganydebristhatcoulddamage thepump.Thestrainershouldbecheckedperiodicallyandfeaturesaclearcapforeasyinspection.Ifanydebrisisfound, removethestrainerscreenby untwistingtheclearcapandcleanthescreen.Thepumpfeaturesabuiltinpressureregulatorthatwillshutthepumpoffwhen pressureisachievedin thesystem.Thefreshwaterwashdown faucetislocatedontheportsideunderthegunwhale cap,justforwardoftheconsole.Ifthesystemhasnot beenusedforaperiodoftime,itmaybenecessarytoprime/bleedthesystemofanyair.Beforeactivatingthepump,openthefreshwaterwashdown faucetandthanswitchonthepump.Whenthesystemisfreeofair,youcaneitherclosethefaucetorshutoffthepump.Itisimportanttocheckthe washdown pumpannuallyandperiodicallysprayitwithacorrosioninhibitor. HardtopMisterPump(Optional) Asanoptionalupgradeforboatswithhardtops,the230BRcanbeequippedwithamistersystem.TheMistersystemusesitsownpump,separatefrom thefreshwaterwashdown pump.Thefreshwaterpumpdoesnotneedtobeontousethemistersystem.Thepumpislocatedadjacenttothefresh waterpumpintheconsole.Thepumpiscontrolledbyaswitchandcircuitbreaker(SeeElectricalSchematic).Freshwaterissuppliedtothemister pumpfromaT‐Connectorinthemainsupplylinefromthetank.Themisterpumpfeaturesanin‐linestrainerforcollectinganydebristhatcould damagethepump.Thestrainershouldbecheckedperiodicallyandfeaturesaclearcapforeasyinspection.Ifanydebrisisfound,removethestrainer screenbyuntwistingtheclearcapandcleanthescreen.Thepumpdoesnotfeatureapressureregulatorandwillruncontinuouslywhenswitchedon. SystemOperationandMaintainence Onlyusepotablefreshwaterinthesystem.Alwaysverifythereissufficientquantityofwaterinthetankbeforeactivatingeitherthewashdown or mistersystem.Insufficientwaterquantitywillcausethepumpstorundryandmayleadtofailure/damage.Beforeusingthe freshwatersystemforthe firsttimeonthewater,fillthetankandcycleallthewaterouttoensurethetankiscleanandfreeofcontainmainents.Afterwardscheckstrainer(s)for debrisandcleanifnecessary. DrainageSystem GeneralOverview Allwaterinthe230BRisdrainedeitherviagravityorpump.Itiseitherdraineddirectlyoverboardortotheaftbilgewhere itcanbedrainedouteither viathegarboarddrainplugorthebilgepump.Itisimportanttocheckthedrainagesystemfrequentlytoverifywaterflows freely,hosesaresecureand therearenoleaks.Thedrainsanddischargepumpsareasfollowsstartingatthebow: AnchorLocker– Gravitydrainalongcenterlineofhulltoaftbilge PortBowLocker– Gravitydrainrunsthroughportstringertoaftbilge StarboardBowLocker– GravitydrainrunsthroughstarboardstringerandconnectsviaT‐ConnectortoTransomcoolerboxdrain Fishbox LipDrain– Gravitydrainrunsalongportsideofhulltoporttransom1‐1/8”ThruHull.Thedrainincorporatesanin‐linecheckvalve. Fishbox Drain– FeedsdirectlytoFishbox MaceratorPump Fishbox MaceratorPump– Locatedinsidetheconsole,dischargestoforwardportthruhullneartransom(SeeNoteABelow) ConsoleRecessDrain– Gravitydrain,drainsdirectlytothebilge Livewell LeaningPostOverflowDrain(Optional)– GravitydrainconnectsviaT‐ConnectortoLivewell LeaningPostDrain Livewell LeaningPostDrain(Optional)– GravitydraintoCenterline1‐1/8ThruHullontransom. PortCockpitDrain– Gravitydraintoporttransom1‐1/2”ThruHull StarboardCockpitDrain– Gravitydraintostarboardinboard1‐1/2”ThruHull Port/StarboardTransomStoragelockers– Gravitydraindirectlytoaftbilge TransomLivewell OverflowDrain– GravitydrainconnectsviaT‐ConnectortoTransomLivewell Drain TransomLivewell Drain– Gravitydraintostarboardtransom1‐1/8”ThruHull CoolerBoxDrain– Gravitydraintoaftbilge AftBilgePump– Locatedinaftbilge,dischargestoaftportthruhullneartransom NoteA:Thefishbox maceratorpumpiscontrolledbyaswitchandcircuitbreaker(SeeElectricalSchematics).Neverrunthepumpdryasitwilldamage thepump.Thefishbox shouldbecleanedaftereveryuseandpumpedoutbeforestoringtheboat. FloorDrainOverview Twoofthemostimportantpiecesofequipmentonyour230BRarethecockpitfloordrainsastheiroperationisintegralto yoursafetyonthewater.At1‐1/2”indiameter,theyaredesignedtoallowmassivequantitiesofwatertoleavethecockpitof yourboatina veryshortperiodoftimeintheeventofaswampingorextremedownfloodingevent.Allthedrainsinyour230BRoperatethisway, however,thefloordrainsaredesignedsothatwatercanonlyflowinonedirection;outofyourboat.Thedrainfeaturesauniquedesign thatactslikeacheckvalvetherebypreventingbackflowofwaterintothecockpitofyourboat. Thedesignofthedrainanditsoperationissolelydependentonthefoamballandsealring.Anydegradationinthefoamwill compromisetheballsabilitytosealagainstthesealring.Therefore,donotapplypowerwashersoranycleaningchemicalsdirectlytothe drainareaasthiswillcompromisethefoamintheball.Whenusingchemicalcleanersinyourboatsinterior,useasufficientquantityof watertodilutethechemical(s)whensprayingoffsothattheydonotaffectthefoamballwhendrainingout. Thesealringneedstobekeptfreeofdebrissothatfoamballwillsealflush.Thedrainfeaturesagratesothatdebriscannot flowintothedrain.Intheeventthatasufficientamountofdebriscollectsaroundtheseal,thegrateandtopofthedrainassemblycanbe removed.Useaspannerwrenchtounscrewthetopofthedrainandcleanthedrainassembly.Thiswillalsoprovideaccesstothefoam ballwhichcanthanberemovedandreplacedifnecessary.Onlydothisifitbecomesevidentthatballisnotsealingproperly. Thiswillbe manifestedbysmallamountsofwatercomingthroughthedrainwhentheboatissittingatrestinthewater.DONOT removethedrain whiletheboatisinthewater. Undernormalconditionswhen thethruhullsareabovewater, theballisbelowthesealring therebyallowingwatertoflow outofthecockpitand overboard Wheneverthethruhullsare submergedbelowwater,back pressuresealsballagainstsealring, creatingawatertightsealand preventsbackflowofwaterfromthe thruhulls. ElectricalSystem GeneralOverview The230BRisequippedwitha12VDCElectricalsystemthatcanbeequippedwithanoptionalACbatterycharger. The230BRcanonlyberiggedforasinglemotor.Iftheboatisriggedwithoutanoptionalbatteryselectorswitch,theboat willberiggedforx1Group27 battery.Ifthebatteryselectorswitchisinstalled,theboatwillberiggedforx2Group27batteries.KeyWestrecommendsthisoptionforthosewho wishtoinstallanoptionalwindlasstotheirboatduetothehighpowerdemand.Thebattery(s)willprovidepowertotheengine,houseandoptional windlasssystem. Allbatteriesandfinalelectricalriggingwillbeperformedbyyourdealerpriortodelivery.Pleaseconsultwithyourdealerregardingthebatteryinstallation ofyourboatpriortotakingdeliveryofyourboat 12Vpowerisdistributedtothe12Vfactoryinstalledsystemsthroughindividualcircuitbreakerslocatedbeneaththeirrespectiveswitchesonthemain switchpanels.All12Vsystemsaregroundedindividuallytoagroundingblocklocatedinsidetheconsole.Thegroundingblockisthangrounded directlytoabattery.A30ampmaincircuitbreakerisinstalledintheconsoletoprotectthehousesystemsfromoverloadandisconnectedeither directlytothebatteriesortheoptionalbatteryselectorswitch.Additionalcircuitbreakersfortheautobilgepumpsandstereomemoryarewired directlytoeitherthebatteryorbatteryselectorswitch.Thesystemisdesignedsothatturningthebatteryswitch/switchesoffwillstillallowthebilge pumpstofunctioninanautomaticmode.KeyWestrecommendsthatboatsthataregoingtobeleftinthewaterorinaboatlift,whereaccesstothe drainplugisnotfeasible,beinstalledwithabatterychargertopreventdischargebythebilgepumps.TrimTabsandoptional powersteeringare connecteddirectlytothebatteryandfeatureovercurrentprotection.Theydonotenergizeuntiltheengineignitionswitchisturnedtothe“On”position. BatteryCharger Asanoption,abatterychargercanbeinstalledthatwillchargeoneorbothbatteries,dependingontheinstallation.ThebatterychargerconvertsAC powerintoDCpowerthatisusedtochargethebatteries.Thechargerispoweredbyaplugontheconsolethatreceivesastandard110Vplugfromthe femaleendofa110Vextensionchord.Itallowsyoutoplugtheboatintoaregular110Voutlet. ElectricalSystemMaintenance Allconnectionsintheelectricalharnessfeaturedeutscheconnectorsandheatshrinkbuttconnectorstominimizecorrosion. KeyWestrecommends thatallconnectionsandterminalsbecheckedatleasttwiceayearandsprayedwithacorrorsion inhibitingsprayatleastonceayeartoprotectand maintaintheintegrityofelectricalconnections.Fortroubleshootingpurposesandfurtherinformation,aschematicoftheelectricalharnessisavailable fordownloadinPDFonthe230BRmainpage.