50 AC Chiller
Transcription
50 AC Chiller
Schreiber high-performance water chillers Engineering Corporation ISO 9001:2000 CERTIFIED since 1958 air cooled capacity: .5 ton ma d e i n th e U . S. A. application: general recommended for all commercial applications Model no. 50 AC GENERAL DATA • Energy Saving Design • Does not use hot gas bypass • Chiller Compressor cycles on and off based on discharge temperature requirements • Digital Temperature Control • Displays discharge and return temperature readings • Pump and compressor shut-off switches • High-Temperature Alarm and contact • All Non-Ferrous plumbing components Trust the Leader Ensure your investment with reliable chilled water. TrueTon engineers design water chillers to be accurately compatible with your specific equipment requirements. We use only the finest, most reliable components to assure reliability and high-performance results. Ranging from 1/3rd ton to 60 ton capacities – we offer a chiller for most applications. • Insulated, double-wall reservoir (non-pressurized) • All-copper evaporator / brazed plate • Powder coated cabinet • 1 Year parts and labor Clearance 12 ft • Condenser (left) 4 ft • Access panel(right) 4 ft • Overflow(rear) 2 ft • Control panel (check code) 3 ft .5 Ton 6,000 BTU/hr 1.76 kW 20 U.S. Gallons DIMENSIONS Width Height Depth 26.5 in. 34.25 in. 32.5 in. WEIGHT Dry Weight 400 lbs ELECTRICAL Volts/Phase FLA Min Amps Max Fuse 115/1 22.0 24.2 30.0 ----- 230/1 Volts 10.6 Amps 11.6 Amps 15.0 Amps MISCELLANEOUS SPECIFICATIONS Charge 2.5 lbs Refrigerant R-22 Compressor FLA 8.8 Amps -- 4 Amps Compressor LRA 58 Amps -- 31Amps Compressor HP 1/2 HP Compressor Type Reciprocating Water Pump FLA 7.8 Amps -- 3.9 Amps Water Pump HP 1/2 HP Water Pump GPM 20 Water Pump Pressure 24.8 P.S.I. Fan FLA 5.4 Amps -- 2.7 Amps Fan HP 1/4 HP Fan Blade Width 16 in. Fans Installed 1 qty. Total Air Flow 400 CFM Fan Speed 1725 RPM Make-up Connection 1/2 in. N.P.T. CHW Connections 1 in. N.P.T. • Stainless steel centrifugal pump • Top fan discharge CAPACITIES Chiller Capacity: @ 44 F Water 95 F Ambient Reservoir Capacity PUMP PERFORMANCE CHART (GPM vs. FT) Install Controls Indoors 250 If you choose to locate the chiller units outdoors, the optional remote control panel enclosure may be installed indoors for easy access, monitoring and conv T o t a l Dy n a mi c He a d ( F t . ) 200 Options • Micro Processor Controls • Outdoor Installation • Pump upgrades 150 100 50 • High ambient package • Tank less Chiller • Call factory for pricing and additional options. Medical Systems l Manufacturing l 0 0 10 Process Cooling l Welding l Aerojet l 20 30 40 50 Ca p a c i t y – U . S. G P M Please contact our engineering department for assistance in the selection of the appropriate chiller equipment for your specific application. Most all Schreiber Chillers have been ETL and CSA Tested and Approved. Heavy Equipment l Automotive l HVAC l More ©2004 Schreiber Engineering Corp. • 50 AC-04 • Specifications subject to change REV. DESCRIPTIONS DATE BY TANK FILL 3" MANUAL 26.596 37.085 32.596 2.000 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCE ARE: FRACTION DECIMALS ANGLES + .XX +.03 +.5 .XXX + .015 MATERIAL FINISH BIRCH WHITE DO NOT SCALE DRAWING Schreiber 12111 EAST PARK STREET Engineering CERRITOS, CA 90703 TITLE FINISHED CABINET 1/2 THRU 1-1/2 TON SIZE SHT1 SHT2 DRAWING NO. B B B DRAWN BY: STEVEN Q. LY DATE: 08.30.02 SCALE: REV A SHT 2 OF 2 REV. CHILLED WATER RETURN TANK FILL 5.999 3.641 17.250 3.689 5.754 3.203 DRAIN ACCESS DOOR 26.939 LEFT FRONT 26.018 32.418 2.064 4.891 8.141 PUMP ROTATION CHECK HOLE 26.508 BY 36.547 32.576 RIGHT CONDENSER DOOR (3 FT CLEARANCE) 17.564 6.439 37.085 34.124 28.064 20.939 CHILLED WATER DISCHARGE DATE 34.124 13.288 SIGHT GLASS (FLUID LEVEL) ELECTRONIC CONTROL CONTROL BOX FAN GUARD 12.250 5.754 3.698 OVER FLOW 20.639 MANUAL TANK FILL 3" DESCRIPTIONS Minimum Clearances: Front : 3 ft (Control Box And Water Connection Right: 3 ft (Condenser Air-Flow) Left: 3 ft (Sight Glass / Drain) Power Input: 230/1; 230/3 OR 460/3 ETL Tested and Approved Rated at ARI Standard of 44 deg.F Chilled Water at 95deg.F ambient Digital Temperature Control R-22 Refrigerant Hermetically Sealed Compressor Submersed Copper Coil Heat Exchanger Double Layer Fluid Reservoir Highly Durable Powder Coated Finish Contaminate Free System With All None-Ferrous Components 11.000 11.597 26.576 17.576 6.000 36.619 32.576 2.250 4.748 18.750 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCE ARE: FRACTION DECIMALS ANGLES + .XX +.03 +.5 .XXX + .015 MATERIAL FINISH BIRCH WHITE DO NOT SCALE DRAWING Schreiber 12111 EAST PARK STREET Engineering CERRITOS, CA 90703 TITLE FINISHED CABINET 1/2 THRU 1-1/2 TON SIZE SHT1 SHT2 DRAWING NO. B B B DRAWN BY: STEVEN Q. LY DATE: 08.30.02 SCALE: REV A SHT 1 OF 2
Similar documents
Excellence in LED vehicle lighting
LED Autolamps is a leading manufacturer of an extensive range of European certified commercial vehicle LED lighting solutions. The company’s commitment to research and development and innovative pr...
More informationSemi-Hermetic and Screw Compressors
Ca_PScat11.12_Layout 1 12/31/12 9:45 AM Page 79
More information