Incubator CO2 series - KW apparecchi scientifici
Transcription
Incubator CO2 series - KW apparecchi scientifici
GreenLine Incubator CO2 series model W180CCI.IR K W A P PA R E C C H I S C I E N T I F I C I Incubator CO2 series model W180CCI.IR W180CCI.IR control panel W180CCI.IR - opened Incubator CO2 series model W180CCI.IR GENERAL CHARACTERISTICS: Structure in electrolytically galvanized sheet steel with high resistance epoxy powder coating. Internal chamber in smooth AISI 304 stainless steel, with rounded edges to avoid contamination, without any surface discontinuity. Any internal parts are removable without the need for tools for maximum cleanliness. Internal door in glass with silicone rubber sealing. Exclusive KW system for controlled heating and ventilation of the internal door in glass sheet: eliminates condensation, ensuring quick temperature recovery after opening the door. Elimination of the condensate on the internal walls and internal door, with an adequate distribution of the thermal flow and with a distinct temperature regulation of the door and the internal chamber. Heating takes place by convective exchange with the air. Separate, easily removable fan. Humidification is obtained through a stainless steel container placed in the bottom of the internal tub which allows it to saturate the chamber atmosphere. CO2 injection is with a PWM solenoid valve system, through an easily replaceable sterilizing filter. Upon opening the door, the μP system controls the thermal energy supply to the minimum level of stability of Tset and interrupts both the flow of CO2 and the microventilation. Upon closing the door, the PWM system ensures a quick restoration without overshooting the set value under the centralized and integrated μP management, which also controls the delay of any alarm activation. The W180CCI.IR is available as a bench or floor model, with or without tubular support, to allow an optimization of space, adapting to every laboratory configuration. The incubator W180CCI.IR is simple and safe to use, through: • Liquid crystal display, alphanumeric with 2 rows of 16 characters (usable area: 20x95 mm); • Messages and indications in Italian or English • Simultaneous indication on display of temperature and CO2 concentration; • Indication on display of alarm status with remote setup; • CO2 and °C display and setting with two dedicated keys; • Password for access to setup of set points and other system parameters; • Differentiated temperature regulation for chamber and door; • Open door sensor with visual acoustic alarm; • CO2 and temperature concentration recovery algorithms optimized to minimize thermal shocks (in particular T overshoot) and concentration; • Mute-capable visual and acoustic alarms of movement from set points: T (min/max) and CO2 % (min/max); • Calibratable overtemperature safety thermostat; CO2 supply pressure from 0.7 to 3 bar; a regular membrane reducer is sufficient for the CO2 tank. CO2 REGULATION: • NDIR infrared beam sensor; • Measurement cell thermostatted at 45°C ±0,2°C, so that ambient temperature and humidity become uninfluential • Regulation range: 0.0÷10.0% standard; 0.0÷20.0% optional; • Precision of measurement and regulation: better than 2% of maximum value; • Resolution and repetitivity: better than 1% of maximum value; • Stability < ± 0.1%; • Uniformity < ± 0.2%; • Programmable min/max alarm thresholds; • Acoustic-visual alarms capable of remote setup; • Zero drift of sensor: less than 2% of maximum value, cleared every 24 hours by automatic calibration system which can be called up by keyboard; • Procedure for span value calibration with reference tank => programme installed in the μP software complete with instruction messages, also for self-maintenance; • Proportional PWM regulation with solenoid valve; • Time to reach set point after opening 30 sec door: < 10 min in standard range; • RH (Relative Humidity) % values > 90% to avoid culture desiccation; • RS485 or RS232 serial port for transfer of signal to PC (optional); • Connection and socket for manual control of CO2. TEMPERATURE REGULATION: • RTD Pt 100 sensor; • Optimized PID control; • Regulation range: from + 5.0 °C above ambient to + 42.0 °C; • Precision of measurement and regulation: better than 0. 1 °C; • Stability < ± 0.1 °C; • Resolution and repetitivity: better than 0. 1 °C; • Uniformity < ± 0. 5 °C of the working volume; • Time to reach set-point: after opening door for 30 sec: < 6 min; • Programmable min/max alarm thresholds; • Acoustic-visual alarms capable of remote setup; • RS485 or RS232 serial output for transfer of signal (optional); • Electronic strip-chart recorder (optional). ACCESSORIES UPON REQUEST: • Tubular floor support; • Tubular floor support with wheels; • CO2 pressure regulator; • Fyrite CO2 analyzer 0-20%; • Supplementary RTD Pt 100 Ohm probe, for connection to external acquisition system and T recorder, such as T-GUARD® and SensiNet®, or similar systems • Additional RTD Pt 100 Ohm probe, complete with 4-20 mA converter, mounted on DIN rails, for connection to external recording system • Electronic strip-chart temperature recorder; • RS485 or RS232 serial port An I.Q. (Installation Qualification) and O.Q. (Operational Qualification) can be carried out on this series of equipment; for an evaluation of the costs of these activities, consult the KW commercial office. KW is also available for ISO calibration certification services for SIT sample comparisons. Model External dimensions (WxDxH) Internal dimensions (WxDxH) Capacity shelves N. Power supply Maximum power Weight W180CCI.IR cm. 92x64x74 h cm. 60x55x56 h litres 180 5 V 220 Hz 50 800 VA Kg. 110 K W A P PA R E C C H I S C I E N T I F I C I Contact us: Managing director: management@kwkw.it Production and technician office: technician@kwkw.it Sales management: sales@kwkw.it Tenders and export office : commerciale@kwkw.it Export support: expdpt@kwkw.it Service and support: assistenza@kwkw.it service@kwkw.it Logistics and shipments: delivery@kwkw.it Administration office: administration@kwkw.it = Min. / max. temperature alarm = Internal light = Power failure alarm = Open door alarm = Lock = Temperature programmer for thermal cycling = Graphic temperature recorder adviseritalia.com = Wheels • W-LAB WR-LAB series legend • WR 90 - 102 series thermostatic chambers / precision incubators refrigerated with water jacket • WI series natural guided convection incubators • W.80 - W.82 series precision water bath • WPL series INCUBATORS table and floor incubators • W.82/O - W.84/O series precision water bath with linear and/or orbital shaking • WPLR series INCUBATORS refrigerated table and floor incubators • W180CCI.IR model CO2 Incubator series • W-LAB series INCUBATORS forced air circulation incubators • WRS 96 - 85 series thermal refrigerating chambers with photoperiod control for environmental simulation • GreenLine Introduction • WR-LAB series INCUBATORS forced air circulation refrigerated incubators • WRC series forced air circulation thermal refrigerator for modern scientific and industrial laboratories • W 90 - 102 series thermostatic chambers / precision incubators with water jacket • WR UR700C model Climate Chamber series for pharmaceutical stability tests and environmental simulation • KW 20/B-100/B KW 6/B-12/B-18/B series modular glass or plastic bottle rollers ø80-120mm • Walk-in incubator • Walk-in stability chamber KW APPARECCHI SCIENTIFICI s.r.l. • 53035 Monteriggioni (SI) • Via della Resistenza, 119 • Tel. +39 0577 309143 / 309145 www.kwkw.it • kw@kwkw.it • sales@kwkw.it