ConVaultPlus STI SP001Compliant
Transcription
ConVaultPlus STI SP001Compliant
ConVault Plus STI SP001Compliant The Only Above Ground Fuel Storage Tank with UL 752 Level 8 Ballistic Rating Fire Protection STI SP001 Compliant EPA Compliant Impact Resistant ConVault’s resistance to blast, projectile, and vehicle impact, exceeds U. L. 2085 specification. ConVault is compliant with EPA regulations, Spill Prevention, Containment, and Countermeasures plans. ConVault’s unique double wall steel tank system allows for testing and inspection compliant with STI SP001. Seamless, six-inch reinforced concrete provides two-hour fire protection as per U. L. 2085 specification. Multiple Size Options Leak Containment Primary Steel Tank Primary steel tank is isolated from the concrete encasement to assure corrosion protection. Thermal Protection ConVault’s monolithic concrete enclosure and insulation layers provide thermal protection. Secondary Steel Tank Second steel tank is isolated from the Primary steel tank allowing for SP001 Testing Compliance. ConVault provides versatile storage solutions with tank sizes ranging from 125 to 12,000 gallons. A high performance, high density polyethylene membrane encloses the primary and secondary tanks and provides leak containment. Above Ground Liquid Storage Solutions www.convault.com 888-965-3227 ConVault Plus Now With a Double Wall Steel Tank to Allow For Easy On-Site Testing ConVault Options Feature/Benefit ConVault ConVault Plus Double Wall Steel Tank SP 001 Test Compliant Primary Steel Tank Secondary Containment Impact Resistant0+ Multiple Size Options EPA Compliant Vehicle0 Ballistics + Thermal Protection Fire Protection* x x x x x x x x x x x x x x x x x x x x ASTM F 2656 - 07 Standard Underwriters Labratory UL 752 Level 8 Ballistics Standard * 4 Hour Rating ASTM E-1529 0 + ConVault Plus Benefits • STI SP001 Compliant - Convault’s unique double wall steel tank system allows for testing and inspection compliant with STI SP001. • Manufactured to the rigid standards of the Oldcastle quality control program at Oldcastle facilities around the country. • Double Wall Steel Tank - Primary and Secondary tanks offer increased protection and allow for testing of interstitial space. • Engineering - Every ConVault tank is designed and engineered to meet or exceed industry requirements for above ground fuel storage. • UL listed - ConVault AST is listed in accordance with ULC 142.16, ULC 142.23 and UL Standard 2085 Insulated/Secondary Containment for Above ground Storage Tanks/Protected Type. • Meets Safety Regulations - ConVault tanks meet all safety requirements for primary and secondary containment, leak monitoring, spill containment and overfill protection. • Environmentally Secure - With multiple layers of containment surrounded by 6” of steel reinforced concrete, ConVault is designed to protect. • LEED - Manufactured locally with recycled material. for potential LEED credits.