Trautman Associates
Transcription
Trautman Associates
Erie 1 BOCES Building Condition Survey Bid Package R14-BCS0514 14 May 2014 TA Proposal 26447 Non-Collusive Project Team + Licensure References Firm Profile Description of Services + Project Scope Fee Schedule B Insurance www.TrautmanAssociates.com Section 1 Section 2 Key Personnel Proposed Project Team Erie 1 Board of Cooperative Educational Services First Supervisory District TRAUTMAN ASSOCIATES LEADERSHIP Richard M. Gehring, AIA - 3ULQFLSDOLQ&KDUJH /LFHQVH1XPEHU Brad V. Vaillancourt, RA, CSI, LEED AP - 3URMHFW$UFKLWHFW /LFHQVH1XPEHU Charles W. Moore, RA, LEED AP - 3URMHFW$UFKLWHFW /LFHQVH1XPEHU Robert P. Stelianou, P.E., Fellow NSPE, LEED AP - &LYLO6WUXFWXUDO(QJLQHHU /LFHQVH1XPEHU John F. Daly, P.E., CPD, CBIE, LEED AP - 'LUHFWRU0HFKDQLFDO(OHFWULFDO3OXPELQJ(QJLQHHULQJ /LFHQVH1XPEHU Richard K. Druzcz, P.E. - (OHFWULFDO(QJLQHHU /LFHQVH1XPEHU Jason E. Mock, P.E. - 0HFKDQLFDO(QJLQHHU /LFHQVH1XPEHU SUB-CONSULTANTS Tremco Brad Farris, CSI 5RRÀQJ6SHFLDOLVWV Trautman Associates Technical Staff ECC Technologies %LOO+D\HV &RPPXQLFDWLRQV6\VWHPV6SHFLDOLVWV BPS )UDQN3LVFLRWWD 6HFXULW\6\VWHPV6SHFLDOLVWV Roth Consulting Group /LQGD5RWK )RRG6HUYLFH&RQVXOWDQW Baer & Associates -RVHSK'RPPHU &RVW(VWLPDWLQJ www.TrautmanAssociates.com Key Personnel Richard M. Gehring, AIA Vice President Mr. Gehring has represented Trautman Associates as a project manager and Principal-inCharge for schools for the past 29 of his 36 year career. His ability to work with administrators, teachers, facilities, Boards of Education, and his architectural / engineering staff has been a valuable asset to numerous school districts. Mr. Gehring’s considerable expertise with the SED process has allowed him to act as an advisor to superintendents, business managers DQG WKH UHVW RI WKH DGPLQLVWUDWLYH WHDP RQ WKH ÀQDQFLDO DVSHFWV DQG PHWKRGRORJ\ 0U Gehring has successfully maximized state aid on several challenging renovation projects and his knowledge and expertise has been instrumental on many projects. Selected Experience 470 Franklin Street Buffalo, New York 14202 P 716 883 4400 F 716 883 4268 Rgehring@TrautmanAssociates.com Barker Central School District, Barker, NY %XLOGLQJFRQGLWLRQVVXUYH\ÀYH\HDUIDFLOLWLHVSODQPLOOLRQFDSLWDOLPSURYHPHQW projects Williamsville Central School District, Williamsville, NY Architectural services since 1965 – more than 200 district-wide projects totaling DSSUR[LPDWHO\PLOOLRQLQFOXGLQJDPXVLFVXLWHDW0LOO0LGGOH6FKRRO Franklinville Central School District, Franklinville, NY PLOOLRQFDSLWDOLPSURYHPHQWSURMHFWVLQFOXGLQJUHQRYDWLRQRIKLVWRULFKLJKVFKRRO auditorium Frontier Central School District, Hamburg, NY \HDUWHUPFRQWUDFWRYHUSURMHFWVWRWDOLQJDSSUR[LPDWHO\PLOOLRQ3URMHFWV include: award- winning Big Tree Elementary School with new 400-seat auditorium Forestville Central School District, Forestville, NY &DSLWDOLPSURYHPHQWVVSDQQLQJIURP²SUHVHQWPLOOLRQLQFOXGLQJD6) Performing Arts Auditorium Grand Island Central School District, Grand Island, NY Long-range capital improvement planning, served as Owner’s representative Education University of Kentucky, Bachelor of Architecture Professional Registered Architect, NY, 1988 American Institute of Architects Adult Residential Care Advocate National Trust for Historic Preservation Habitat for Humanity Key of Hope Award 2004 Contributor US EPA, NYS Asbestos Training Building Inspector / Management Planner www.TrautmanAssociates.com Key Personnel Brad V. Vaillancourt, RA, CSI, LEED AP Project Architect Mr. Vaillancourt has 11 years of architectural experience, and has served six years on the 470 Franklin Street Buffalo, New York 14202 staff of Trautman Associates with considerable experience in State Education Department P 716 883 4400 F 716 883 4268 contributor to our educational design team, in addition to work completed for commercial Bvaillancourt@TrautmanAssociates.com and feasibility studies. (SED) process, residential, and commercial architectural design. Mr. Vaillancourt is an active clients. He has performed architectural programming, design, construction administration, Selected Experience Barker Central School District, Barker, NY Capital Improvement Projects including school addition and improvements, and building FRQGLWLRQVXUYH\1<6(5'$TXDOLÀHGHQHUJ\HIÀFLHQWOLJKWLQJDQGHOFWULFPRWRUXSJUDGH Williamsville Central School District, Williamsville, NY Capital Improvement Projects, school addition and renovations Forestville Central School District, Forestville, NY Capital Improvement Projects, school addition and renovations, SED Forms, code review, drawings, and construction documents. Received NYSERDA rebates and was awarded 2011 American School & University Educational Interiors Showcase for Outstanding Design Grand Island Central School District, Buffalo, NY Capital improvement projects, school renovations, district-wide building condition surveys Eden Central School District, Eden, NY &DSLWDOLPSURYHPHQWSURMHFWVVFKRROUHQRYDWLRQV6(')RUPVVSHFLÀFDWLRQVFRGHUHYLHZ drawings West Valley Central School District, West Valley, NY &DSLWDOLPSURYHPHQWSURMHFWVVFKRROUHQRYDWLRQV6(')RUPVVSHFLÀFDWLRQV Education SUNY Buffalo, Bachelor of Professional Studies in Architecture SUNY Buffalo, Masters of Architecture Professional Registered Architect, New York, 2007 USGBC LEED Accredited Professional Tapestry Charter School - volunteer for “Experience Play & Learning Project” www.TrautmanAssociates.com Key Personnel Charles W. Moore, RA, LEED AP Project Architect Mr. Moore has 38 years of professional experience, and has served ten years on the staff 470 Franklin Street Buffalo, New York 14202 of Trautman Associates with expertise in renovation and rehabilitation projects. He has P 716 883 4400 F 716 883 4268 variety of projects, including educational, governmental, institutional, and commercial. performed architectural design, production, and project administration services for a cmoore@TrautmanAssociates.com Selected Experience Niagara County Community College, Sanborn, NY Gym and Locker Room Renovations Grand Island Central School District, Grand Island, NY Kaegebein School Capital Improvements Nichols School, Buffalo, NY Window Replacement Grand Island Central School District, Grand Island, NY Roof Replacement Grand Island Central School District, Grand Island, NY Capital Improvement Projects – Sidway School Masonry Repairs; Huth Road Masonry Repairs Cheektowaga-Maryvale Central School District*, Buffalo, NY Capital Improvement Projects, Middle School Masonry Repairs SUNY at Buffalo*, Buffalo, NY Ellicott Complex Plaza Roof Deck and Masonry Parapet Reconstruction Alfred University*, Alfred, NY Complete Building Renovation, Engineering Technology Alfred University*, Alfred, NY Complete Building Renovation, Binns Merril Hall *Under previous association Education Kansas State University, Bachelor of Architecture Erie Community College, Associate’s Degree Building/Technology Professional Registered Architect, New York, 1988 www.TrautmanAssociates.com Key Personnel Robert P. Stelianou, P.E., Fellow NSPE, LEED AP Vice President / Director Civil, Structural Engineering Mr. Stelianou serves as Civil / Structural group leader and is responsible for civil / structural HQJLQHHULQJ GHVLJQ DQG FRQWUDFW GRFXPHQW SUHSDUDWLRQ IRU PDQ\ RI WKH ÀUP·V SURMHFWV He has 33 years of experience in civil / structural engineering design and production, all 33 years he has served as a key member on the Trautman Associates staff. Mr. Stelianou has performed professional services for a variety of client types, including governmental, educational, industrial, and commercial clients. Selected Experience St. Mary’s School for the Deaf, Buffalo, NY Drainage study and improvements 470 Franklin Street Buffalo, New York 14202 P 716 883 4400 F 716 883 4268 rstelianou@TrautmanAssociates.com Sisters of St. Francis, Williamsville, NY Design of new 105,000 SF Community Living Center Stella Niagara, Stella Niagara, NY Improvements made to Health Center and convent Lancaster Central School District, Lancaster, NY Design and construction of new 139,000 SF middle school Nichols School, Buffalo, NY 5HSODFHPHQWRIURRIDQGFRSSHUÁDVKLQJ Williamsville Central School District, Williamsville, NY Building repairs and renovations, construction of new middle school Forestville Central School District, Forestville, NY Construction of 25,500 SF addition housing new Performing Arts Auditorium and renovations made to existing 76,000 SF of high school Nardin Academy, Buffalo, NY Construction of 11,600 SF addition to house Montessori School Education Virginia Polytechnic Institute and State University, Bachelor of Civil Engineering Professional Professional Engineer, NY, 1985 National Society of Professional Engineers Fellow, 2009 National Society of Professional Engineers Past Vice President of WNY; Past Chapter President ASCE Structural Clinic of Buffalo Past Chapter President www.TrautmanAssociates.com Key Personnel John F. Daly, P.E., CPD, LEED AP, CBIE Director of Mechanical, Electrical, Plumbing Engineering &HUWLÀHG%XLOGLQJ,QVSHFWLRQ(QJLQHHU 9LFH3UHVLGHQW 0U 'DO\ KDV \HDUV RI H[SHULHQFH LQ WKH HQJLQHHULQJ FRQVWUXFWLRQ LQGXVWU\ +H KDV LQVWUXFWHGSOXPELQJFXUULFXODWRLQGXVWU\WUDGHDVVRFLDWLRQVVXFKDV%XLOGLQJ2ZQHUVDQG 0DQDJHUV$VVRFLDWLRQ%20$$PHULFDQ,QVWLWXWHRI$UFKLWHFWV$,$DQG$PHULFDQ6RFLHW\ RI 3OXPELQJ (QJLQHHUV $63( $OVR 0U 'DO\·V LQYROYHPHQW ZLWK WKH 86 *UHHQ %XLOGLQJ &RXQFLODQGKLVUROHDVDQDGYRFDWHRIVXVWDLQDEOHGHVLJQSUDFWLFHVWHFKQRORJLHVSROLFLHV DQGVWDQGDUGVPDNHVKLPDYDOXDEOHNQRZOHGJHDEOHUHVRXUFH 470 Franklin Street Buffalo, New York 14202 P 716 883 4400 F 716 883 4268 Jdaly@TrautmanAssociates.com 6HOHFWHG([SHULHQFH Frontier Central School District+DPEXUJ1< 1HZ$OWHUQDWLYH(GXFDWLRQIDFLOLW\ZLWKJHRWKHUPDO+9$&V\VWHP Grand Island Central School District, *UDQG,VODQG1< %XLOGLQJFRQGLWLRQVXUYH\DQGORQJUDQJHSODQQLQJ Cheektowaga-Sloan Union Free School District &KHHNWRZDJD1< (QHUJ\EDVHGSHUIRUPDQFHFRQWUDFWLQFOXGLQJFRJHQHUDWLRQSODQWDQG+9$&XSJUDGHV Nichols School%XIIDOR1< 'DQQ,FH5LQNHPLVVLYLW\VWXG\ERLOHUUHSODFHPHQWDW$OEULJKWDQG0LWFKHOO+DOOV Williamsville Central School District:LOOLDPVYLOOH1< +9$&V\VWHPUHGHVLJQUHSODFHPHQWRIFKLOOHUVOLJKWLQJGHVLJQXSJUDGHV Buffalo Public Schools%XIIDOR1< 0HFKDQLFDOHOHFWULFDOSOXPELQJDQGÀUHSURWHFWLRQGHVLJQDQGUHSODFHPHQWWRQXPHURXV city schools Alleghany Central School District$OOHJKDQ\1< 3RROGHVLJQDQGUHQRYDWLRQ (GXFDWLRQ %DFKHORURI6FLHQFHLQ0HFKDQLFDO(QJLQHHULQJ6WDWH8QLYHUVLW\RI1HZ<RUNDW%XIIDOR 0DVWHURI%XVLQHVV$GPLQLVWUDWLRQ&DQLVLXV&ROOHJH Professional 3URIHVVLRQDO(QJLQHHU1< /(('$FFUHGLWHG3URIHVVLRQDO 1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ $PHULFDQ6RFLHW\RI3OXPELQJ(QJLQHHUV $PHULFDQ6RFLHW\RI0HFKDQLFDO(QJLQHHUV 1DWLRQDO6RFLHW\RI3URIHVVLRQDO(QJLQHHUV www.TrautmanAssociates.com Key Personnel Ryszard K. Druzcz, P.E. Senior Electrical Engineer Mr. Druzcz is a recent addition to Trautman Associates and brings 32 years of experience in 470 Franklin Street Buffalo, New York 14202 electrical engineering. He has designed electrical systems in new and renovated buildings P 716 883 4400 F 716 883 4268 and institutional facilities. Mr. Druzcz specializes in analysis of electrical power systems Rdruzcz@TrautmanAssociates.com GHYLFHFRRUGLQDWLRQDQGDUFÁDVKKD]DUGVWXGLHV for clients in healthcare, education, commercial, laboratories, military installations, LQFOXGLQJ VKRUW FLUFXLW FXUUHQW ORDG ÁRZ FDOFXODWLRQV HTXLSPHQW HYDOXDWLRQ SURWHFWLYH Selected Experience Williamsville Central School District, Williamsville, NY Facilities improvement and preservation plan - Phase III - replacement of electrical services DQGGLVWULEXWLRQV\VWHPVLQÀYHHOHPHQWDU\VFKRROVDQGWZRKLJKVFKRROV Maryvale Central School District*, Cheektowaga, NY Building Condition Survey to determine condition of electrical systems in six school buildings and included recommendations for corrections and improvements Schenectady Central School District*, Schenectady, NY Building Condition Survey identifying condition of electrical systems in 21 school facilities. Report assessed emergency power system, fire alarm and communication systems West Seneca Central School District*, West Seneca, NY Design services for a facilities and technology improvement project for 10 school buildings, bus garage, and buildings and grounds department facility Niagara University*, Lewiston, NY Programming, planning and design services for electrical systems for a $13 million, 50,000 SF academic building addition and 10,000 SF renovation space 800 West Ferry Condominiums, Buffalo, NY Replacement of electric service switchboards, distributioon system and panelboards in 12-story apartment building Ellicott Development Corp., Buffalo, NY Design of new six-story hotel and apartment building, including design of electrical systems, electric service, backup generator, lighting, power and systems *Prior Association Education Warsaw Polytechnic, Warsaw, Poland, Master’s Degree in Electrical Engineering Professional Registered Professional Engineer, New York www.TrautmanAssociates.com Key Personnel Jason E. Mock, P.E. Mechanical Engineer Mr. Mock has nine years of professional experience in renovation and capital improvement 470 Franklin Street Buffalo, New York 14202 engineering projects and has served two years on the staff of Trautman Associates. He P 716 883 4400 F 716 883 4268 educational, governmental, commercial, medical, light industrial, and institutional facilities. Jmock@TrautmanAssociates.com both new construction and renovations. has performed mechanical engineering services for a multitude of projects including 0U0RFN·VH[SHULHQFHKDVIRFXVHGRQHQHUJ\HIÀFLHQW+9$&PHFKDQLFDOV\VWHPVGHVLJQIRU Selected Experience Cantalician Center for Learning, Depew, New York 5HQRYDWLRQRIDQH[LVWLQJFKXUFKDQGVFKRROIDFLOLW\DQGDGGLWLRQ+9$&GHVLJQZLWK K\GURQLFDQGDLUVLGHHTXLSPHQWDQGQHZYDULDEOHUHIULJHUDQWÁRZV\VWHP(TXLSPHQWDQG V\VWHPGHVLJQIRFXVLQJRQHQHUJ\HIÀFLHQF\DQGHDVHRIXVH Buffalo Public Schools capital Improvement Projects, Buffalo, New York Buffalo Public Schools 17,19,32,37,45, 76, and 206 5HQRYDWLRQDQGPRGHUQL]DWLRQRIH[LVWLQJVFKRROEXLOGLQJV+9$&V\VWHPVDQGFRQWUROV Oracle Charter School, Buffalo, New York* Parkville Charter School, Brooklyn, New York* Canisius High School, Buffalo, New York* Math, science and gymnasium additions South Elmwood Charter School, Buffalo, New York West Virginia Central School District, .DQDZKD&RXQW\:HVW9LUJLQLD (QHUJ\SHUIRUPDQFHGHVLJQIRUÀYHHOHPHQWDU\VFKRROVLQ.DQDZKD&RXQW\:HVW9LUJLQLD Design work included steam and hot water boiler replacement, improved or replaced controls and sequences *Under previous association Education SUNY Buffalo,Bachelor of Science in Mechanical Engineering Professional Registered Professional Engineer, NY 2012 $PHULFDQ6RFLHW\RI+HDWLQJ5HIULJHUDWLQJDQG$LU&RQGLWLRQLQJ(QJLQHHUV%XIIDOR &KDSWHU www.TrautmanAssociates.com Bradford Farris P.O. Box 239 East Aurora, New York 14052 Phone: 716.462.8912 Email: bfarris@tremcoinc.com 2006–Present Tremco Inc., Roofing & Building Maintenance Position: Architectural Specialist ¾ Provide Roofing-focused building condition investigations/surveys for multiple roofing system types (Metal, EPDM, PVC, TPO, CSPE, Built-Up, Modified-Bitumen, SPF, etc.) including the following measures: 9 Infrared Scan / Tramex / Capacitance Probe roof moisture surveys 9 Roofing core cuts to determine construction 9 Visual roof inspections 9 Forensic roofing investigation and analysis 9 Roofing repair, restore, retrofit and replacement solutions 9 Specification review 9 Code compliance review 9 Construction detail drawings 9 Budget estimates ¾ 10 Hour OSHA Certified ¾ Member, Construction Specifications Institute ¾ Multiple Tremco Team members in Western New York are Snell-Certified Infrared Thermographers. ¾ Various measures of practice noted above successfully completed for multiple architectural and engineering firms for the following school districts: • Erie 1 Boces (Potter Road, Kenmore-Tonawanda & Harkness facilities) • Buffalo Public Schools (No's 12, 17, 69, 54, 61, 64, 74, 79, 84, 97, 200 & 203) • Cheektowaga-Sloan UFSD Dunkirk CSD East Aurora UFSD • Eden CSD Ellicottville CSD Falconer CSD • Fredonia CSD Frontier CSD Gates-Chili CSD • Hamburg CSD Kenmore-Tonawanda UFSD Lake Shore CSD • Lancaster CSD Maryvale UFSD Niagara Wheatfield CSD • Tonawanda CSD West Seneca CSD Williamsville CSD ¾ References available upon request. 1993–2006 Metal Sales Manufacturing Corp. Position: Territory Manager Jefferson, Ohio Western New York & Southern Ontario ¾ Managed sales, estimating and technical installation inspections for commercial metal roofing and wall systems manufacturer. 1992 Canisius College Bachelor of Science, Business Administration Buffalo, NY Bill Hayes Sr. Technology Consultant Bill Hayes is a Sr. Technology Consultant for ECC specializing in the planning, funding, design, and implementation of complex technology projects. He has recently joined ECC and has previous experience in managing operations for a large architectural and engineering firm that served DOD, K12, and Municipal clients. Mr. Hayes has provided Senior Project Management on projects that have exceeded $100M in value. His electrical and technology engineering experience combined with over 30 years of project and construction management experience provide unique skills for complex technology projects. Mr. Hayes’s previous projects involve significant technology upgrades with related facility improvements for educational clients. He is experienced with the planning, design, implementation, and management of IP networks, data centers, voice and data communications systems, IP security, fiber optic and leased broadband WANs, and wireless and cabling infrastructures. His understanding of K12 technology applications for eLearning, curriculum integration of digital content, distance learning, computer based testing and BYOD demands are essential to develop technology plans and associated capital projects to meet the District’s educational vision. Representative Projects Include Lockport City School District – Lockport ,NY District Wide Technology Project—Pre-Referendum Planning and follow on Design Services for a $7M District Wide Technology & Security Project. The project includes VOIP Telephone system, replacement of cabling infrastructure, telecommunication closet improvements, wireless and network electronics upgrade with 10GE WAN and IP video systems and display devices plus IP security enhancements. Keshequa Central School District – Nunda, New York District Wide Telephone System Replacement Project— Assessment of existing NORTEL PBX and voicemail systems and scope and budget cost to replace with a new Cisco telephone and voice mail system. IP telephones will be installed throughout the district and new cabling and network electronics upgrades will be included. Converged data and voice IP network to achieve district wide communication across the existing 100MBS WAN. Telephone PSTN services will be revised to reduce operational cost. York Central School District – Restof, New York VOIP Network Readiness Study & Pre-Referendum Planning for a District Wide Telephone System Replacement Project. Assessment of existing NORTEL PBX and voicemail systems and scope and budget cost to replace with a new Mitel VOIP and Cisco network solution. SUNY Brockport – Brockport, NY Campus Wide Network Electronics and Wireless Upgrade to provided robust wired and wireless data capabilities to support growing demand for bandwidth across the campus. Faculty and students are typically bringing 3-4 devices on campus, which all require connectivity to the network. The new network electronics and wireless solution will be based on a Cisco platform and utilizing the new 802.11ac wireless access points to significantly enhance wireless connectivity in all facilities and outdoor venues on the campus. Project cost is approximately $2M and ECC Technologies will also assist College IT staff with implementing the solution. ECC Technologies is also assisting the College IT Department and Facilities Planning Department with the development of a migration strategy to implement Voice Over IP (VOIP) to approximately 2000 staff and students located on Campus and at the Downtown Rochester Metro Center Campus. Frank Pisciotta, President 250 Gorham Street Canandaigua, New York 14424 (585) 394-5112 x11 Professional Qualifications Masters of Professional Studies BA, Criminal Justice Former Certified Protection Professional (ASIS) Career History Business Protection Specialists, Inc. Accomplished manager in a security consulting firm with 14 years of security experience in educational, healthcare, petroleum, industrial, and manufacturing environments. A self-starter with proven business, leadership, operational, and analytical skills coupled with an outstanding work ethic. Results include: x Double digit sales growth for each of the first 12 years of business. x Providing security advice for over 80 clients. New York State Security Certification Trainer Serving as director and trainer for New York State Certified Security Guard Training School. Results include: x Expanded school operations in the first six years of business. Now maintaining multiple training sites for a multitude of clients employing proprietary security forces. x Developed and obtained state approval for two security training curriculums from New York State Department of State - Division of Licensing. x Elevated to director’s role by retaining multiple trainers to assume operational responsibilities. Federal / State Law Enforcement Accreditation Served three police departments as a technical writer developing policies and procedures to achieve compliance with Federal and State Law Enforcement Accreditation programs. Alfred University Managed 40-person security staff providing protective services to a campus of several thousand students. Developed security department through the implementation of written procedures, training documents, and crisis management protocol. Development of complete Corporate Security Programs Designed, developed, and deployed: x Corporate policies and procedures. x Threat assessment and security incident reporting program. x Minimum security standards for operating sites. x Security operating and emergency procedures. x Security awareness programs for employees. x Procurement and design standards for security systems. x Resource planning (how to manage the program after it is built). Threat Assessment Program Development Developed proprietary process to identify and classify security threat for client operations. Threat assessment classification aids site management in identifying the degree of effort and energy required to address and mitigate security risk resulting from vulnerabilities. Risk assessment Conducted multiple assessments at manufacturing, refinery, chemical, and industrial sites across the U.S. and internationally. Developed risk assessment models and program for New York State school districts. Customized program based on customer-intimate knowledge. Executed program in 5 districts. Technical security projects Participated in nationwide card access standardization project with Mobil Chemical Company. Designed and specified multiple access control, alarm monitoring, and CCTV systems for educational, manufacturing, and petroleum sites. Roth Consulting Group, Inc. 424 Bewley Building, Lockport, New York, 14094 Women Business Enterprise Key Personnel Linda S. Roth President B.P.S. Architecture State University at Buffalo AAS Architecture SUNY at Delhi, Delhi NY x x x Publication Contributing Editor to FOCUS magazine Published by New York School Nutrition Association Professional Affiliations Foodservice Consultant Society International (FCSI), Professional Member NY School Nutrition Association, Business Member American Institute of Architects, Associate Member LEED Green Associate, 2013 As president Linda is not only responsible for the daily operation of the company, but also is actively involved in project design and equipment selection from initial conception through facility opening and beyond. Linda’s architectural background and previous work experience with foodservice facilities designers and equipment dealers has created a well rounded knowledge of the industry. Communicating the foodservice requirements to the Owner and Architect throughout the length of the project, as well as, developing the program into a space that meets the client needs and is an appealing place is of paramount importance. Christopher Young Design Drafting x x x Bachelor in Fine Arts, Interior Design Buffalo State College Chris’s current design work is centered in the K-12th Grade and Correctional markets. Equipment selection and operational requirements are critical to the design and layout being completed. Chris’s past employment brings a working knowledge of sales and retail to Roth Consulting Group. Mechanical / Electrical / HVAC detail drawings and schedules are Christopher’s responsibility. Providing the necessary architectural information to the design team is paramount to the project completion. Page |1 JOSEPH M. DOMMER PRESIDENT, BAER & ASSOCIATES, LLC Experience Buffalo Public Schools Reconstruction – Buffalo, New York - Phases I, II, III, IV & V - BPS #12 – Window Replacement - BPS #80 – Roof Work - Master Plan Update – Phase 4 - BPS #65 – Library/Cafeteria Renovation Rochester Public Schools – Rochester, New York Modernization Program, Phase I - Charlotte High School South Buffalo Charter School – Buffalo, New York - Secondary Gymnasium Alfred-Almond Central School District – Almond, New York - Gymnasium Improvements Mexico Central School District – Mexico, New York - Gymnasium Addition - Middle & High School Additions & Renovations Jamestown City School District - Jamestown, New York - Bush Ring Elementary Schools - Jefferson Middle School Additions, Alterations - New Technology Academy - Fletcher Elementary School - New Bus Garage - Capital Project Idea Friendship Central School District – Friendship, New York - Renovations & Gym Addition East Aurora High School – East Aurora, New York - Gym/Pool Re-Roof Buffalo Academy of Science Charter School – Buffalo, New York - Gymnasium Improvements Niagara Falls City School District - Niagara Falls, New York - Niagara Street Elementary School - LaSalle Middle School Total Years of Experience 22 Education Erie Community College Civil Engineering/Construction Technology Advisory Council Professional Affiliations American Society of Professional Estimators UB – Center for Entrepreneurial Leadership American Institute of Architects Buffalo NY Chapter Affiliate Member Boys & Girls Clubs of the Northtowns - President Construction Exchange of Buffalo and WNY – Board of Governors Hilbert College – Board of Trustees Baer & Associates, LLC Construction Consultants 4588 South Park Avenue Blasdell, NY 14219 700 River Avenue, Suite 543 Pittsburgh, PA 15212 Phone: 716-831-0000 Fax: 716-831-0001 www.baer-associates.com Section 3 References “In summary, I can attest to the knowledge and integrity that Trautman Associates brought to Grand Island.” Thomas M. Ramming )RUPHU6XSHULQWHQGHQW *UDQG,VODQG&HQWUDO School District Trautman Associates has completed hundreds of school projects during the past \HDUV2XUÀUPKDVGHYHORSHGDQH[SHUWLVHIRFXVHGRQSXEOLFVFKRROVDQGPDQ\ of our relationships with school districts span 10 years or more. Lockport City School District Michelle Bradley, Superintendent of Schools ( PEUDGOH\#ORFNSRUWZQ\ULFRUJ P: 716-478-4835 'HERUDK$&RGHU$VVLVWDQW6XSHULQWHQGHQWIRU)LQDQFH0DQDJHPHQW6HUYLFHV ( GFRGHU#ORFNSRUWZQ\ULFRUJ P: 716-478-4828 “The Board hired Trautman Associates, a local, H[SHULHQFHGÀUPZLWK a proven background in educational facility projects.” 5RJHU.ODWW Superintendent %DUNHU&HQWUDO School District “You and your staff have done a highly professional job orchestrating the building renovation project at Forestville CSD.” Phillip Benson )RUPHU6XSHULQWHQGHQW )RUHVWYLOOH&HQWUDO School District 7LPRWK\3DUNHU6XSHULQWHQGHQWRI%XLOGLQJV*URXQGV ( WSDUNHU#ORFNSRUWZQ\ULFRUJ P: 716-439-6496 3DWULFN0%XUNH'LUHFWRURI+HDOWK3K\VLFDO(GXFDWLRQ$WKOHWLFV ( SEXUNH#ORFNSRUWZQ\ULFRUJ P: 716-478-4473 Williamsville Central School District 7KRPDV0DWXUVNL$VVLVWDQW6XSHULQWHQGHQWIRU)LQDQFH0DQDJHPHQW6HUYLFHV ( WPDWXUVNL#ZLOOLDPVYLOOH.RUJ P: 716-626-8012 Forestville Central School District &KDUOHV/HLFKQHU6XSHULQWHQGHQWRI6FKRROV ( FOHLFKQHU#IRUHVWYLOOHFRP P: 716-965-2742 -RKQ2·&RQQRU)RUPHU6XSHULQWHQGHQWRI6FKRROV P: 716-549-4454 6WHYH$UQROG)DFLOLWLHV0DQDJHU ( VDUQROG#IRUHVWYLOOHFRP 3 H[W &DURO\Q$5REHUWVRQ&3$%XVLQHVV$GPLQLVWUDWRU ( FUREHUWVRQ#IRUHVWYLOOHFRP P: 716-965-6533 www.TrautmanAssociates.com References ´)URPVWDUWWRÀQLVK Trautman Associates and their architectural teams have been professional, forthright and totally competent in all phases.” Richard Wachter Former Superintendent Franklinville Central School District Eden Central School District 'DYLG0DUWLQ6XSHULQWHQGHQWRI%XLOGLQJV*URXQGV ( GPDUWLQ#HGHQFVGZQ\ULFRUJ P: 716-992-3602 5RQDOG.%XJJV)RUPHU6XSHULQWHQGHQWRI6FKRROV ( UEXJJV#QLDJDUDFDWKROLFRUJ P: 716-283-8771 Grand Island Central School District 7KRPDV05DPPLQJ)RUPHU6XSHULQWHQGHQWRI6FKRROV ( WUDPPLQJ#YHUL]RQQHW P: 716-689-1527 “On behalf of the Board of Education and Administration, please accept our sincere appreciation for the efforts made by yourself and your staff so the addition was available for the opening of school.” Richard A. Binner Former Assistant Superintendent for Business Frontier Central School District Frontier Central School District *HUDOG3*ORVH(G')RUPHU6XSHULQWHQGHQWRI6FKRROV ( JHUDOGJORVH#YHUL]RQQHW P: 716-627-4391 5LFKDUG$%LQQHU)RUPHU$VVLVWDQW6XSHULQWHQGHQWIRU%XVLQHVV P: 716-656-0716 Tapestry Charter School Joy Pepper, Director ( MR\S#WDSHVWU\VFKRRORUJ 3 H[W (ULF.ODSSHU&KLHI2SHUDWLQJ2IÀFHU ( NODSSHU#WDSHVWU\VFKRRORUJ 3 H[W Nichols School of Buffalo 'DQLHO('RODQ&KLHI)LQDQFLDO2IÀFHU ( GGRODQ#QLFKROVVFKRRORUJ P: 716-332-6305 -DG&RUGHV6FKRRO%RDUG0HPEHU2ZQHU·V5HSUHVHQWDWLYH ( MFRUGHV#LUGSURMHFWPDQDJHUVFRP 3 H[W www.TrautmanAssociates.com References “Please know that you have all our heartfelt thanks for what as a team so many have created.” Barker Central School District 5RJHU.ODWW6XSHULQWHQGHQWRI6FKRROV ( UNODWW#EDUNHUFVGQHW P: 716-795-3832 7KHUHVH6FRÀGLR ([HFXWLYH'LUHFWRU &DQWDOLFLDQ&HQWHUIRU /HDUQLQJ www.TrautmanAssociates.com Section 4 )LUP3URILOH2YHUYLHZ 2IÀFH )UDQNOLQ6WUHHW %XIIDOR1HZ<RUN 7HOHSKRQH )D[ (VWDEOLVKHG $3URIHVVLRQDO&RUSRUDWLRQIRXQGHG LQLQ%XIIDOR1< History 7UDXWPDQ.LQJ0DUNZDUW$VVRFLDWHV3& GED7UDXWPDQ$VVRFLDWHV )HGHUDO,' '816 )RUPHU1DPHV :LOOLDP57UDXWPDQ3(7XUOH\7UDXWPDQ6FKOHQNHU 6FKOHQNHU7UDXWPDQ$VVRFLDWHV 1XPEHURI(PSOR\HHV WHFKQLFDODQGVXSSRUWVWDII² DUHD/LFHQVHG$UFKLWHFWRU(QJLQHHU RIVWDIILVFHUWLÀHGDVD/(('$3 0DUNHW6HFWRUV (GXFDWLRQ(OHPHQWDU\6HFRQGDU\ (GXFDWLRQ&ROOHJH8QLYHUVLW\ *RYHUQPHQW ,QGXVWULDO +HDOWKFDUH 5HOLJLRXV Housing &RPPHUFLDO5HWDLO 6HUYLFHV $UFKLWHFWXUH Planning &LYLO(QJLQHHULQJ 3OXPELQJ(QJLQHHULQJ )LUH3URWHFWLRQ(QJLQHHULQJ 6WUXFWXUDO(QJLQHHULQJ (OHFWULFDO(QJLQHHULQJ 0HFKDQLFDO(QJLQHHULQJ &RQVWUXFWLRQ$GPLQLVWUDWLRQ6HUYLFHV 6SHFLDOWLHV 3URMHFW3ODQQLQJ 6XVWDLQDEOH'HVLJQ²/(('$FFUHGLWHG6WDII $GDSWLYH5HXVH +LVWRULF3UHVHUYDWLRQ )XOO$UFKLWHFWXUDO'3KRWR5HDOLVWLF5HQGHULQJV *RYHUQPHQWDODQG0XQLFLSDO$SSURYDOV3HUPLW www.TrautmanAssociates.com Firm Profile Design Philosophy Accountability Trautman Associates architects and engineers have built a solid repeat client base upon our professionalism, our ingenuity and our integrity. Working to understand our clients’ needs, limitations and goals we work as a team in the ongoing development of innovative solutions to the built environment. The synergy of design disciplines translates into a WHDPZLWKH[FHOOHQWFRPPXQLFDWLRQDQGHIÀFLHQWFRRUGLQDWLRQDFWLQJDVDVLQJOHVRXUFHRI performance responsibility and accountability. 7KHÀUP·VRZQHUVKLSLVLQYROYHGGDLO\ZLWKDOODVSHFWVRIRXUSURMHFWV8QOLNHRWKHUÀUPV the principals at Trautman Associates are not only managers, but leaders by example. 5HDG\WRKHOSRXUFOLHQWVDQGRXUVWDIIÀQGWKHULJKWVROXWLRQQRPDWWHUWKHSUREOHP Sustainability Trautman Associates mechanical, electrical, and plumbing engineers are responsive to WKHQHHGIRUUHOLDEOHDQGHQHUJ\HIÀFLHQWV\VWHPV1HDULQJVL[GHFDGHVRIH[SHULHQFH we continue to advance our discipline, building state-of-the-art systems tailored to meet our clients’ needs. With the proper sizing and selection of high-performance equipment, ZHSURYLGHVXVWDLQDEOHVROXWLRQVWRWKHEXLOWHQYLURQPHQWWKDWTXDQWLÀDEO\UHGXFHHQHUJ\ FRQVXPSWLRQDQGRSHUDWLQJFRVW8WLOL]LQJWKHODWHVWWHFKQRORJ\WRKDUQHVVIUHHHQHUJ\ from simple methods such as daylight harvesting and photovoltaic collectors to geothermal heating and cooling systems, we have been better able to achieve overall design synthesis, collaborating across disciplines in the collective effort to minimize the carbon footprint of HYHU\SURMHFW 7KH8QLWHG6WDWHV*UHHQ%XLOGLQJ&RXQFLO·V/HDGHUVKLSLQ(QHUJ\DQG(QYLURQPHQWDO 'HVLJQ/(('SURJUDPZRUNVWRUHFRJQL]HEXLOGLQJVDQGUHZDUGRZQHUVZKRKDYHPDGH VLJQLÀFDQWFRQWULEXWLRQVWRZDUGVXVWDLQDELOLW\7UDXWPDQ$VVRFLDWHVKDVVHYHUDO/((' accredited professionals on staff. Their expertise and knowledge of integrated design LVRIWHQSLYRWDOLQVHFXULQJDGGLWLRQDOSURMHFWIXQGLQJVRXUFHVDQGFRPPXQLW\ZLGH UHFRJQLWLRQIRU/(('FHUWLÀHGSURMHFWV 1<6(5'$.QRZOHGJHDQG([SHULHQFH 7UDXWPDQ$VVRFLDWHVLVSURXGWREHUHFRJQL]HGDVD1<6(5'$1HZ<RUN6WDWH(QHUJ\ 5HVHDUFKDQG'HYHORSPHQW$XWKRULW\UHFRPPHQGHGÀUP7UDXWPDQ$VVRFLDWHVDQG 1<6(5'$KDYHEXLOWDVWURQJDOOLDQFHRYHUWKH\HDUV0DQ\RIRXUVWDQGDUGHQJLQHHULQJ SUDFWLFHVDUHFRQVLGHUHGE\1<6(5'$WREH´SUHDSSURYHGPHDVXUHVµDQGDUHLPPHGLDWHO\ HOLJLEOHIRUUHEDWH7KURXJK1<6(5'$ZHKDYHEHHQVXFFHVVIXOLQVHFXULQJKXQGUHGVRI thousands of dollars in cost incentives for our clients. 8QLYHUVDO'HVLJQ *RRGGHVLJQVKRXOGEHLQKHUHQWO\DFFHVVLEOH7UDXWPDQ$VVRFLDWHVHQFRXUDJHVLWV designers to think broadly about usability, integrating it into our overall design strategy as a fundamental guiding principle above and beyond the blanket requirements of the ADA. www.TrautmanAssociates.com Firm Profile Licensed Professionals Discipline State Registrations John J. Vujnovic, AIA Architect NY Richard M. Gehring, AIA Architect NY Richard P. Kuchta, RA Architect NY Charles W. Moore, RA Architect NY James M. Radwan, AIA Architect NY Robert M. Radwan, RA Architect NY Timothy M. Rider, AIA Architect NY Robert H. Rumpl, AIA, CSI Architect NY Richard J. Stievater, AIA Architect NY Brad V. Vaillancourt, RA Architect NY John F. Daly, PE Engineer – Mechanical NY Richard K. Druzcz, PE Engineer – Electrical NY Jason E. Mock, PE Engineer – Mechanical NY Marc F. Petryk, PE Engineer – Electrical NY Paul R. Rosnak, PE Engineer – Mechanical NY Robert P. Stelianou, PE, F. NSPE Engineer – Civil NY Accredited LEED Professionals by the U.S. Green Building Council John F. Daly, PE John Sisting Ivan R. McMillen Robert P. Stelianou, PE, F.NSPE Charles W. Moore, RA Anna E. Szweda Timothy M. Rider, AIA Brad V. Vaillancourt, RA /LJKWLQJ&HUWLÀHG1DWLRQDO&RXQFLORQ4XDOLÀFDWLRQVIRUWKH/LJKWLQJ3URIHVVLRQV Ivan R. McMillen 1<6(5'$&HUWLÀHG+LJK3HUIRUPDQFH6FKRRO'HVLJQHU John J. Vujnovic, AIA Timothy M. Rider, AIA John F. Daly, PE Ivan R. McMillen Richard P. Kuchta, RA Lisa J. Lubozynski Brad V. Vaillancourt, RA Anna E. Szweda www.TrautmanAssociates.com Section 5 Description of Services Building Condition Survey: Basic Proposal Trautman Associates (TA) has provided Building Conditions Surveys (BCS) to numerous school districts since the State Education Department (SED) mandated this program. We also are involved with school safety committees that complete the Annual Visual Inspection (AVI) each year. Similar to SED, we have revised RXU SURFHVV DQG HQKDQFHG WKH VSHFLÀF EXLOGLQJ LQVSHFWLRQ FRPSRQHQWV WR EH FRQVLVWHQWZLWK6('FXUUHQWZHEEDVHGIRUPDW7RRXUNQRZOHGJHWKHIRUPDW KDV QRW EHHQ UHOHDVHG VR ZH ZLOO SURSRVH RXU ZRUN EDVHG RQ WKH IRUPDW :KLOHOLVWHQLQJWR0U7KXUQDXDWWKH0DUFK6XPPLWLQ$OEDQ\KHGLGQRWVXJJHVW WKHUHZRXOGEHVLJQLÀFDQWFKDQJHVDQGWKDWWKHÀQDQFLDOUHLPEXUVHPHQWZRXOGEH LQFUHDVHGWR²SHUVTXDUHIRRW:HKDYHVWUXFWXUHGRXUEDVLFVHUYLFHV DVQRWHGEHORZDQGZLOOXWLOL]HRXUIXOOVHUYLFH$(ÀUPWRFRPSOHWHWKLVSRUWLRQRI your proposal. Upon contractual agreement with the school district we will schedule VLWHYLVLWVWRHDFKIDFLOLW\DVGLUHFWHGE\WKHDXWKRULW\DWWKDWVFKRRO:HW\SLFDOO\ VXJJHVWWKDWRQHIDFLOLW\SHUGD\EHXQGHUWDNHQDQGDJURXSLQWURGXFWLRQZLWKWKH SDUWLFXODUEXLOGLQJHQJLQHHUSHUVRQSUHVHQW 7RPD[LPL]HWKHXVHRIRXUSHUVRQQHOZHUHFRPPHQGWKDWDUFKLWHFWVDQGHQJLQHHUV VSOLWWKHLUWLPHZLWKWKHEXLOGLQJSHUVRQQHOEHWZHHQDEXLOGLQJWRXUDQGDVLWGRZQ QDUUDWLYHXWLOL]LQJWKH%&6DQG$9,DVDQDJHQGD,QWKLVPHWKRGRQH WHDPWRXUVWKHEXLOGLQJZKLOHWKHRWKHUUHYLHZVWKHSUHYLRXVVFKRROUHFRUGVDQG discuss existing conditions with school personnel. We will have a licensed engineer IRU HDFK PDMRU WUDGH SOXPELQJ +9$& (OHFWULFDO DQG )LUH 3URWHFWLRQ 6WUXFWXUDO DQG &LYLO $ OLFHQVHG $UFKLWHFW ZLOO EH LQYROYHG ZLWK WKH JHQHUDO FRQVWUXFWLRQ EXLOGLQJHOHPHQWVDORQJZLWKDSULQFLSDOLQFKDUJHDFWLQJDVWKHSURMHFWPDQDJHU RYHUVHHLQJWKHWDVNVGD\,WQRUPDOO\WDNHVDIXOOGD\WRFRPSOHWHWKHQDUUDWLYHDQG WRXURIHDFKEXLOGLQJDQGDVHFRQGGD\LQRXURIÀFHFRPSOHWLQJWKHIRUPZRUNDQG UHVHDUFK UHTXLUHG WR HVWDEOLVK EXGJHW HVWLPDWHV IRU QHHGHG LPSURYHPHQWV DQG FRQÀUPGDWHVRILQSODFHV\VWHPV 7RFRPSOHWHHDFKEXLOGLQJSURMHFWPDQDJHUVUHYLHZDGUDIWFRS\RIWKHLUVXUYH\ ZLWKWKHGLVWULFWSURSRVDORIWKHLUFKRLFH:HW\SLFDOO\EXGJHWDSSUR[LPDWHO\ PDQKRXUVWUDGHHQJLQHHUVDQGRQHDUFKLWHFWIRUKRXUVHDFKIRUWKHWDVNV GHVFULEHGIRUHDFKEXLOGLQJ:KLOHSHUIRUPLQJWKHWDVNVHQXPHUDWHGDERYHSKRWRV DQGVSHFLÀFQRWHVDUHWDNHQWRSUHSDUHIRUHQKDQFHGVHUYLFHVDVGLVFXVVHGLQWKH next section. Building Condition Survey: Enhanced Proposal 7$ZLOOSURYLGHHQKDQFHGVHUYLFHVIRUWKHEXLOGLQJFRQGLWLRQVXUYH\DVGHVLUHGE\WKH GLVWULFW·VVSHFLÀFQHHGV7KHUHTXLUHPHQWIRUWKHVHVHUYLFHVDUHDWWKHGLVFUHWLRQRI WKHGLVWULFWDQGDUHQRWPRQLWRUHGZLWKWKHVDPHLQWHQVLÀFDWLRQDVWKH%&6 SED only suggests via a very generic “recap” template on how each district should IRUPDWWKHLUORQJHUDQJHSODQQLQJ7KLVDORQJZLWK6HFWLRQRIWKH www.TrautmanAssociates.com FRPPLVVLRQHUV UHJXODWLRQV VXPPDUL]H WKLV UHTXLUHPHQW )RU WKLV UHDVRQ 7$ KDV DVVHPEOHGDGRFXPHQWDQGUHYLHZHGLWZLWK6('WRFRQÀUPLWPHHWWKHLULQWHQWLRQ IRUORQJUDQJHSODQQLQJDOVRNQRZQDVWKHÀYH\HDUSODQ7KLVZDVZHOOUHFHLYHGE\ 6('DQGXVHGIRUVHYHUDOGLVWULFWVLQ ,QRXULQWHUSUHWDWLRQRI\RXUUHTXHVWHGHQKDQFHGVHUYLFHVZHFRQVLGHUWKHIROORZLQJ WDVNVWREHLQFOXGHGLQWKLVFDWHJRU\ I Long Range Planning II Assembling Operation Costs III Assembly of Maintenance and Repair Costs IV Investigative Studies V Inventory of expensed costs allowances for construction and incidentals VI Capital Project Planning VII Alternative Program Collection Methods VIII 5RRÀQJ6SHFLDOL]DWLRQ IX 7HOHFRPPXQLFDWLRQV7HFKQRORJ\6\VWHPV6SHFLDOL]DWLRQ X )RRG6HUYLFH6SHFLDOL]DWLRQ (DFK RI WKHVH ZLOO EH GLVFXVVHG LQ WKH IROORZLQJ VHFWLRQV ZLWK WKH VFRSH RI RXU SURSRVDOGHVFULEHGLQGHWDLO I Long Range Planning ,QLWLDWHG E\ WKH %&6 WKH FXVWRPL]HG VSUHDGVKHHW DVVHPEOHV LWHPV LQ D VLPLODU JURXSLQJDQGLGHQWLÀHVWKHYDOXHRIZRUNWKDWLVDLGHGIRUHDFKRIWKHQH[WÀYH\HDUV VHH([KLELW$,QFUHDWLQJWKLVWRROZHUHYLHZHGWKHFRPPLVVLRQHU·VUHJXODWLRQV DQGFUHDWHGDORFDWLRQIRUHDFKWDVNWKDWZDVUHTXHVWHG%\WKHIXQFWLRQVSURYLGHG E\WKHVSUHDGVKHHWVRIWZDUHZHDUHDEOHWRVRUWWKHLQIRUPDWLRQDVGHVLUHG)RU H[DPSOH E\ QRWLQJ UHSDLU RU FDSLWDO SURMHFW ZH FDQ FROOHFW RQO\ WKH UHSDLU LWHPV DQGSURYLGHWKDWWRWKHIDFLOLWLHVGHSDUWPHQWIRUWKHLUDQQXDOEXGJHWSUHSDUDWLRQ 6LPLODUO\E\SULRULWL]LQJZRUNLWHPVWKURXJKZHFDQTXLFNO\GHYHORSDOLVWRIZRUN WKDWFRUUHODWHVWRDQLGHQWLÀHGFDSLWDOH[SHQGLWXUH :HKDYHDOVRPDQDJHGWKLVW\SHRIGDWDFROOHFWLRQE\JURXSLQJWKHEXLOGLQJE\WKH \HDU FRQVWUXFWHG 0RVW EXLOGLQJV KDYH KDV DGGLWLRQV RYHU WKH \HDUV DQG YDULRXV DVVHPEOLHVLQWKHEXLOGLQJFDQQRWEHVRUWHGXQGHULGHQWLFDOFDWHJRULHV2XUPHWKRG gives a true reading of each component part of the structure. Additionally, we have H[WHQGHG QXPHURXV ZRUN FDWHJRULHV WR DFFRXQW IRU YDULRXV ZRRG ÁRRU ÀQLVKHV VHHLWHPRQ([KLELW$$QRWKHUH[DPSOHRIH[WHQGLQJEXLOGLQJFDWHJRULHVWR correlate to the elements is with windows. Seldom are all the windows the same W\SHRUDJHDQGDFFRXQWLQJIRUERWKSURYLGHVWKHDELOLW\WRUDWHHDFKIRUSRWHQWLDO expenditure. )LQDOO\ZHKDYHDOVRGHYHORSHGDPHWKRGIRUFKDUWLQJZDUUDQW\SHULRGV7KHUHDUH www.TrautmanAssociates.com Description of Services numerous products that are repeatedly researched to determine if they are still in ZDUUDQW\$VVHPEOLQJWKRVHGDWHVLQWRWKHVXUYH\VLPSOLÀHVWKHSURFHVV II Operational Cost Included in our LRP is space for monitoring operational costs. This mainly refers WR XWLOLWLHV JDV HOHFWULFDO IXHO ZDWHU EXW FRXOG DOVR EH H[WHQGHG WR LQFOXGH PDLQWHQDQFH HTXLSPHQW 8SRQ FROOHFWLRQ RI WKLV GDWD WKH IDFLOLWLHV GHSDUWPHQW FDQ DJDLQ EXGJHW PRUH DFFXUDWHO\ IRU IXWXUH \HDUV DQG HYDOXDWH LI FRVW VDYLQJ PHDVXUHVDUHZRUNLQJ III Maintenance and Repair Costs 7KLV SRUWLRQ RI WKH /RJ 5DQJH 3ODQ KDV EHHQ GLVFXVVHG EXW ZH HPSKDVL]H WKH LPSRUWDQFHRIGHYHORSLQJDEXGJHWIRUQRQDLGDEOHPDLQWHQDQFHDQGUHSDLUZRUN 7KLV FROOHFWLRQ RI ZRUN ZLWK VRPH HQKDQFHPHQW PD\ EH DOWHUHG DQG PD\ EH FRQVLGHUHGDUHLPEXUVDEOHFDSLWDOSURMHFWIRUVLPLODUFRVWVLHDGGLQJWRSFRXUVH WRSDYHPHQWYHUVXVUHFRQVWUXFWLRQRIEDVHFRXUVHRQVLWH IV Investigative Studies ´$Q\EXLOGLQJV\VWHPWKDWQHHGVDQLQGHSWKLQYHVWLJDWLRQWRGHWHUPLQHFRQGLWLRQ UHPDLQLQJXVHIXOOLIHRUFRVWWRUHSODFHIRUH[DPSOHVKRXOGEHLQFOXGHGLQWKHVXUYH\FRVWµ Carl Thurnau 1HZVOHWWHU1<6('2IÀFHRI)DFLOLWLHV 0U7KXUQDXVWDWHGWKLVLQKLVQHZVOHWWHUQR7KLVZDVUHSHDWHGDWWKH6XPPLW LQ$OEDQ\WKLV\HDUDQGZHVXEVHTXHQWO\KDYHDVVHPEOHGVHYHUDOVSHFLÀFVWXGLHV WKDWZLOOHQKDQFHDQ\GLVWULFW·VNQRZOHGJHRIWKHLUIDFLOLWLHVDQGPDNHWKHPPRUH DZDUHRIQHHGHGFDSLWDOUHSDLUV6('1HZVOHWWHU([KLELW% 7KH WHDP RI $UFKLWHFWV (QJLQHHUV 6SHFLÀHUV 3URGXFW 5HSUHVHQWDWLYHV DQG &RQWUDFWRUV KDV DJUHHG WR ZRUN GLUHFWO\ ZLWK XV WR SURYLGH DSSURSULDWH VWXGLHV of systems and materials that licensed professionals do not have the expertise, LQVXUDQFHRUHTXLSPHQWWRSURYLGH Type of studies include: (YDOXDWLRQRI.LWFKHQHTXLSPHQWDQGSURSHUH[KDXVWLQJ ,QYHVWLJDWLRQRIHOHFWULFDOGLVWULEXWLRQQHWZRUNDQGDVEXLOWUHFRUGV • Roof scans for determining insulation values and degree of damaged insulation ,QYHVWLJDWLRQRIK\GURQLFKHDWSLSLQJV\VWHPDQGEDODQFLQJRSHUDWLRQ +9$&EDODQFHUHSRUWVRIGXFWZRUNDQG&)0UHSRUWLQJ 7HFKQRORJ\LQYHVWLJDWLRQRIEXLOGLQJLQIUDVWUXFWXUHDQGZLUHOHVVFDSDELOLW\ 7HOHSKRQHDQGQHWZRUNLQYHVWLJDWLRQ • Photography investigation of underground sanitary and storm sewer conductors • Lighting studies comparing cost savings for LED replacement www.TrautmanAssociates.com V Inventory of MCA Expenses :H KDYH EHFRPH DZDUH WKDW PDQ\ GLVWULFWV KDYH QRW WUDFNHG WKHLU SDVW SURMHFWV FRVW DFFXUDWHO\ DQG XSRQ VXEPLVVLRQ WR 6(' GR QRW UHFHLYH WKH DLG WKH\ KDG HQYLVLRQHG7KLVEHFDPHPRUHFULWLFDOZKHQ6('UHHVWDEOLVKHGKRZFRQVWUXFWLRQ DQG LQFLGHQWDO DOORZDQFHV DUH SHUPLWWHG LQ DFFRUGDQFH ZLWK RYHUDOO ZRUN VFRSH timeframes: ´+RZHYHUZHKDYHVHOHFWHGD\HDUF\FOHDVDUHDVRQDEOHDQGDSSURSUL ate time frame to provide access to the Maximum Cost Allowance (MCA). 7KLVDSSURDFKDOLJQVZHOOZLWKRWKHUUHTXLUHPHQWVVXFKDVWKH\HDU UHTXLUHPHQWIRUWKHEXLOGLQJFRQGLWLRQVXUYH\µ Carl Thurnau 1HZVOHWWHU1<6('2IÀFHRI)DFLOLWLHV 0U7KXUQDXDQGWKHFRPPLVVLRQKDVVHOHFWHGD\HDUSHULRGIRUDFFHVVLQJWKH maximum cost allowance (MCA) for any one project site. This means monitoring DOOWKHGLVWULFW·VEXLOGLQJVDQGUHFRUGLQJSDVWH[SHQVHVIRUERWKFRQVWUXFWLRQDQG LQFLGHQWDOFDWHJRULHVLQDQHIIRUWWRFRRUGLQDWHEXGJHWDU\DSSURSULDWLRQVDFURVVDOO district projects. ([KLELWV & DQG ' DUH VDPSOHV RI KRZ ZH KDYH WUDFNHG WKHVH SDVWDFWLYLWLHV DQG advised the district on aided portion of the project and estimated district share YDOXH7KHWUDFNLQJRIDOORZHG0&$YDOXHVFDQRQO\EHGRQHDIWHUDFXUUHQWEXLOGLQJ XVDJHLVFRPSOHWHG0RVWHGXFDWLRQDOEXLOGLQJVGRQRWKDYHFXUUHQWEXLOGLQJDQG units (BAUs) calculated and SED will only reference past project records if this WDVN LV QRW XSGDWHG ,W LV RXU RSLQLRQ WKDW WKHVH VHUYLFHV DUH ZLWKLQ WKH VWDWH·V JXLGHOLQHVIRUWKH%&6UHLPEXUVHPHQWIRUPXODDQGVKRXOGEHFRPSOHWHGIRUHDFK EXLOGLQJ WR SURYLGH WKH GLVWULFW LPSURYHG DFFXUDF\ RI DLG UHLPEXUVHPHQW ([KLELW 'LVDVLPLODUSURFHVVRIYDOLGDWLQJGLVWULFWZLGH.FODVVURRPVDQGMXVWLI\LQJWKH QHHGIRUFRQVWUXFWLRQRIQHZEXLOGLQJDGGLWLRQV VI Capital Project Planning 7$KDVSURYLGHGWKHVHVHUYLFHVWRQXPHURXVGLVWULFWVLQWKHSUHUHIHUHQGXPSKDVH $VGLVFXVVHGDERYH0&$LQYHQWRU\WKLVLVDFULWLFDOVWHSWRWDNHZKHQDGGUHVVLQJ LQIUDVWUXFWXUH LPSURYHPHQWV DQG IXWXUH EXLOGLQJ QHHGV 7KH OLVW RI UHTXLUHG HTXLSPHQWUHSODFHPHQWPXVWEHEDODQFHGZLWKWKHDOORZDEOHVWDWHUHLPEXUVHPHQW ([KLELW(LQGLFDWHVKRZWKLVFRXOGEHPDQDJHGDW6ZHHW+RPH&6'ZKHQWKHUH FDSLWDOSURMHFWZDVEHLQJDVVHPEOHG VII Alternative Building Condition Survey 7$ KDV H[SHULHQFH ZLWK DOWHUQDWLYH &DSLWDO 3URMHFW 6RIWZDUH ERWK IRU H[HFXWLQJ 6('·V%&6DQGSURMHFWSODQQLQJ,Q7$ZRUNHGZLWK(GHQ&6'DQG&DS3UR 6RIWZDUHKDVGHYHORSHGZLWK%2&(6WRFRPSOHWHWKHLU%&6DQG\HDUIDFLOLW\SODQ 7$KDVDOVRZRUNHGIRU:&6'IRURYHU\HDUVDQGUHJXODUO\LQWHUIDFHZLWKWKHPRQ www.TrautmanAssociates.com Description of Services VIII 5RRÀQJ6SHFLDOL]DWLRQ )RUWKHIROORZLQJVFRSHRIZRUN ,QIUDUHG6FDQDQGRU7UDPH[PRLVWXUHVXUYH\RIORZVORSHURRÀQJVHFWLRQV ,QGLFDWHGZHWLQVXODWLRQDUHDVWREHRXWOLQHGRQURRIVXUIDFHZLWKPDUNLQJSDLQW 4XDQWLI\QXPEHURIZHWDUHDVDQGRYHUDOOZHWYVGU\VTXDUHIRRWDJHWRWDOV Photo summary to provide limited examples of indicated wet areas. Notes: %DOODVWHGVLQJOHSO\PHPEUDQHVDUHQRWLQFOXGHG 7HVWLQJWREHFRPSOHWHGGXULQJVXQVHWHYHQLQJKRXUV )DYRUDEOHZHDWKHUFRQGLWLRQVVXQQ\GU\ORZZLQGPXVWH[LVWDWWLPHRIVXUYH\ $FFHVVWREXLOGLQJVWREHSURYLGHGE\WKHEXLOGLQJRZQHU %XLOGLQJRZQHUWRHQVXUHQRVWDQGLQJZDWF·IH[LVWVRQURRÀQJVXUIDFHVDWWLPH of survey. 8QOHVV DOO :RUN KHUHXQGHU LV WR EH SHUIRUPHG ZLWKLQ WKLUW\ GD\V :7, VKDOO VXEPLW DQ LQYRLFH WR WKH &XVWRPHU DW WKH HQG RI HDFK FDOHQGDU PRQWK IRU WKH DPRXQWGXHIRUWKHSRUWLRQRIWKH:RUNFRPSOHWHGGXULQJWKDWPRQWK,IDOO:RUNLV WREHSHUIRUPHGZLWKLQWKLUW\GD\VQRLQYRLFHVKDOOEHVXEPLWWHGXQWLODOO:RUN KDVEHHQ FRPSOHWHG&XVWRPHUVKDOOSD\ :7, LQ IXOOZLWKLQ WKLUW\ GD\V DIWHU receipt of each invoice. 3ULFHRISHUVTXDUHIRRWZLWKDPLQLPXPFKDUJHRISHUEXLOGLQJ IX &RPPXQLFDWLRQVDQG1HWZRUN6\VWHPV6SHFLDOL]DWLRQ 7KH%&6GRHVQRWUHTXLUHWKHDVVHVVPHQWRIWHOHFRPPXQLFDWLRQVQHWZRUNLQJ RU VHFXULW\ V\VWHPV 7KHVH DUH FULWLFDO V\VWHPV IRU DOO VFKRROV DQG VKRXOG EH HYDOXDWHGIRU'LVWULFWVWRDFKLHYHHGXFDWLRQDOJRDOVRSHUDWLRQDOHIÀFLHQFLHVDQG VDIHW\VWDQGDUGVWKDWDUHH[SHFWHGRIDOOVFKRROGLVWULFWVLQWRGD\·V.HGXFDWLRQDO HQYLURQPHQWV7KH1HZ<RUN6WDWHEXGJHWLQFOXGHV%IRUWKH6PDUW 6FKRROV ,QLWLDWLYH $OO VFKRRO GLVWULFWV DFURVV WKH VWDWH KDYH EHHQ SURYLGHG ZLWK LQIRUPDWLRQRQWKHDVVRFLDWHG6PDUW6FKRROVIXQGLQJDOORFDWLRQ,IWKH1RYHPEHU WK6PDUW6FKRRO5HIHUHQGXPLVVXFFHVVIXOWKLVQHZIXQGLQJFDQEHXWLOL]HGWR SXUFKDVHHTXLSPHQWDQGDOVRXSGDWHWHOHFRPPXQLFDWLRQV\VWHPVDQGQHWZRUNV Preliminary information on this program has indicated that a technology assessment DQG SODQ PXVW EH GHYHORSHG WR DFFHVV WKLV IXQGLQJ 7KHUHIRUH WKH ´(QKDQFHG %&6 6WXGLHVµ OLVWHG EHORZ ZLOO VXSSRUW WKLV UHTXLUHPHQW DQG SRVLWLRQ WKH school district to access the Smart Schools Initiative funding. /LVWHG EHORZ DUH VHYHUDO ´(QKDQFHG %&6 6WXGLHVµ WKDW FDQ EH SURYLGHG to assists school districts in understanding the condition and associated recommendations and cost of improving these systems. www.TrautmanAssociates.com A. Telephone System Study: 7KHWHOHSKRQH6\VWHP6WXG\ZLOOEHDQDVVHVVPHQWRIWKHFXUUHQWWHOHSKRQHDQG YRLFHPDLOV\VWHPVRQDQLQGLYLGXDOVFKRRODQGGLVWULFWZLGHEDVLV0DQ\WHOHSKRQH V\VWHPVDUHWHQRUPRUH\HDUVROGDQGDUHQRZEHLQJXSJUDGHGWR9RLFHRYHU,3 92,3 WHOHSKRQH V\VWHP WKDW XWLOL]H WKH GDWD QHWZRUN IRU YRLFH FRPPXQLFDWLRQ (YDOXDWLRQRIDOOWHOHSKRQHELOOVZLOODOVREHLQFOXGHGZLWKUHFRPPHQGDWLRQVRQKRZ to lower operational costs. Recommendations will include the scope and cost of a QHZWHOHSKRQHV\VWHPYRLFHPDLODQGRUXQLÀHGFRPPXQLFDWLRQVDQGDVVRFLDWHG QHWZRUN LPSURYHPHQWV WR VXSSRUW QHZ 92,3 WHOHSKRQH V\VWHPV SOXV DQWLFLSDWHG DQQXDORSHUDWLRQDOFRVW3ULRULW\(UDWHIXQGLQJ 3URSRVHG)HHIRUWKH7HOHSKRQH6\VWHP6WXG\LV6) % 1HWZRUN6WXG\ 7KHQHWZRUNVWXG\ZLOOLQFOXGHDVVHVVPHQWRIWKHFXUUHQWQHWZRUNDQGWKHFDSDELOLW\ RI WKH QHWZRUN WR VXSSRUW QHZ DSSOLFDWLRQV VXFK DV 92,3 ,3 6HFXULW\ Emergency Communications and Wireless. This evaluation will also include review of the FDEOLQJLQIUDVWUXFWXUHZLWKLQWKHIDFLOLWLHVDQGRQFDPSXVDQGWHOHFRPPXQLFDWLRQV URRPV RU UDFN ORFDWLRQV $V PRUH FULWLFDO EXLOGLQJ DSSOLFDWLRQV DUH EHLQJ SODFHG RQ WKH QHWZRUN )LUH $ODUP ''& 7HOHSKRQH 6HFXULW\ 0DVV 1RWLÀFDWLRQ 3DUHQW $OHUW7H[W0HVVDJHVLWLVQHFHVVDU\WRPDNHVXUHWKHWHOHFRPURRPVV\VWHPV are “hardened” to stay in operation even when there is a loss of power or disaster in the community. We will evaluate all of the ancillary systems that support the QHWZRUNVRWKDWDOOFULWLFDOV\VWHPVFDQFRQWLQXHWRRSHUDWHLQDQHPHUJHQF\7KLV VWXG\ZLOODOVRLQFOXGHUHYLHZRI%2&(6GDWDFLUFXLWVDQGFRRUGLQDWLRQRIHTXLSPHQW DQGVHUYLFHVSURYLGHGE\%2&(6 3URSRVHG)HHIRUWKH1HWZRUN6WXG\LV6) & :LUHOHVV1HWZRUN6WXG\ :LUHOHVV QHWZRUN VWXG\ ZLOO LQFOXGH WKH HYDOXDWLRQ RI WKH FRYHUDJH GHQVLW\ DQG WUDQVPLVVLRQ FDSDELOLWLHV RI WKH ZLUHOHVV QHWZRUN 7KH 6WDWH·V JRDO RI LQLWLDWLQJ &RPSXWHU%DVHG7HVWLQJLQWKH6SULQJRIZLOOUHTXLUHDOOGLVWULFW·VWRFRPSOHWH a Technology Readiness study for PARCC Assessment. A critical component of this LV WKH FDSDELOLWLHV RI WKH ZLUHOHVV QHWZRUN WR VXSSRUW D KLJK GHQVLW\ RI VWXGHQWV WDNLQJWHVWDQGWKHDVVRFLDWHGSHUIRUPDQFHRIWKHQHWZRUNDQGLQWHUQHWDFFHVV7KH Wireless Study will evaluate all of these interconnected components and provide UHFRPPHQGDWLRQVDQGFRVWRIDQ\QHFHVVDU\XSJUDGHV)RUPRUHLQIRUPDWLRQRQ Technology Readiness for PARCC Assessments please refer to: KWWSVZZZSDUFFRQOLQHRUJWHFKQRORJ\ 3URSRVHG)HHIRUWKH:LUHOHVV1HWZRUN6WXG\LV6) www.TrautmanAssociates.com Description of Services D. Security, Video Surveillance and Access Control Study: Security is a critical aspect of school operations and having the proper system to protect the staff and students is a high priority for school districts. This Enhanced %&6VWXG\ZLOOUHYLHZWKH6HFXULW\9LGHR6XUYHLOODQFHDQG$FFHVV&RQWUROV Systems that are currently in place and provide recommendation on how to improve WKHVHV\VWHPVWRPHHWWKH'LVWULFW·V6DIHW\3ODQVDQGDOLJQZLWK1HZ<RUN6WDWH Safe Schools Against Violence in Education (SAVE) KWWSZZZSQ\VHGJRYVVVVVDHVFKRROVDIHW\VDYH ,PSOHPHQWDWLRQRIWKHVHV\VWHPVW\SLFDOO\UHTXLUHVXSJUDGHVWRWKH,31HWZRUNDQG FRRUGLQDWLRQZLWKDUFKLWHFWXUDOLPSURYHPHQWVWRFUHDWHYLVLWRUDFFHVVOREELHV7KH study will include these associated recommendations so a complete understanding of the scope and costs are provided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ÁDWSDQHOV 7KH&$79,39LGHR'LVWULEXWLRQ6WXG\ZLOOLQFOXGHWKHDVVHVVPHQWRIWKHH[LVWLQJ 79 GLVWULEXWLRQ V\VWHP DQG RSWLRQV WR LPSOHPHQW DQ ,3 EDVHG YLGHR GLVWULEXWLRQ V\VWHP 7KLV ZLOO DOVR LQFOXGH 9LGHR &DSWXUH DQG 'LVWULEXWLRQ FDSDELOLWLHV IRU lectures, announcements, professional development, district wide video stream of a live or recorded Superintendent’s announcement or Board Meeting. 3URSRVHG)HHIRUWKH&$79,39LGHR'LVWULEXWLRQ6WXG\LV6) ) 'LVSOD\'HYLFH6WXG\ 2YHU WKH SDVW GHFDGH PDQ\ VFKRRO GLVWULFWV KDYH LPSOHPHQWHG GLVSOD\ GHYLFHV VXFKDV6PDUW%RDUGV3URMHFWRUVDQGÁDWSDQHOVWKDWDUHUHTXLUHGWREHSK\VLFDOO\ PRXQWHG LQ WKH IDFLOLWLHV DQG WKHQ LQWHUFRQQHFWHG WR WKH FRPSXWHU DQG QHWZRUN systems. As the digital curriculum evolves many of these display devices may now EHRXWGDWHGRULQSRRUFRQGLWLRQWRFRQWLQXHWRPHHWWKHHGXFDWLRQDOQHHGVRIWKH District. The Display device study will evaluate all of these assets and how they are LQVWDOOHG WR GHWHUPLQH LI XSJUDGHV WR WKH H[LVWLQJ GHYLFHV DUH UHTXLUHG RU LI QHZ GLVSOD\GHYLFHVVKRXOGEHSURYLGHG7KLVZLOOUHTXLUHFROODERUDWLRQZLWKWKH'LVWULFW 7HFKQRORJ\&RPPLWWHH7KHÀQDOUHFRPPHQGDWLRQDQGFRVWZLOODOVRVXSSRUWWKH QHFHVVDU\ LQIRUPDWLRQ WKDW ZLOO QHHG WR EH VXEPLWWHG WR VHFXUH 6PDUW 6FKRROV Initiative funding for these devices. www.TrautmanAssociates.com 3URSRVHG)HHIRUWKH'LVSOD\'HYLFH6WXG\LV6) X )RRG6HUYLFH6SHFLDOL]DWLRQ $WWKLVWLPHZHZRXOGDQWLFLSDWHRXUVFRSHRIZRUNZRXOGLQFOXGH 3UHSDUH H[LVWLQJ IRRGVHUYLFH HTXLSPHQW GUDZLQJV IRU WKH EXLOGLQJ DUHDV GLUHFWO\LPSDFWHGE\WKHZRUNLQWHQGHGUHODWLYHWRWKHIRRGVHUYLFHRSHUDWLRQ 7ZRPHHWLQJZLWKWKH)DFLOLWLHV2SHUDWRU$UFKLWHFWWRRXWOLQHUHQRYDWLRQ RUIRRGVHUYLFHHTXLSPHQWFKDQJHV Prepare a scoping report that would include overall condition of the HTXLSPHQWDQGSURSRVHGFKDQJHVWRPHHWWKHQHHGVDQGUHTXLUHPHQWVRI WKH )RRGVHUYLFH 'HSDUWPHQW 1RWH 5RWK &RQVXOWLQJ *URXS ZLOO QRW VWDUW WDNHDSDUWRUUHFRPPHQGSDUWUHSODFHPHQWRIDQ\IRRGVHUYLFHHTXLSPHQW 2XU JHQHUDO REVHUYDWLRQ DJH RI WKH HTXLSPHQW ZKHUH PDQXIDFWXUHU LQIRUPDWLRQLVDYDLODEOHDQGLQGXVWU\VWDQGDUGVZLOOEHXVHGLQGHWHUPLQLQJ WKHUHFRPPHQGHGHTXLSPHQWFKDQJHVRXWOLQHGLQWKH6FRSLQJ5HSRUW Schematic Design Prepare conceptual layouts of functional areas to identify planning options, determine preferred options, and explain implications such as cost, IXQFWLRQDOEHQHÀWVVW\OHRIRSHUDWLRQDQGLPSDFWRQDGMDFHQWDUHDV 2XU IHH IRU D VWXG\ RI WKLV W\SH LV QRUPDOO\ EXGJHWHG EHWZHHQ DQG GHSHQGHQWRQWKHRSHUDWLRQVL]HDQGORFDWLRQ,XQGHUVWDQGWKHDZDUG LVEDVHGRQDOXPSVXPDPRXQWSHUVTXDUHIRRWDQGWKDWWKHVWDWHZRXOGUHLPEXUVH WKHSURMHFWDQHVWLPDWHGSHUIRRW,ZRXOGQRWHWKDWWKHDYHUDJHIRRG VHUYLFHNNLWFKHQVHUYLQJDUHDLVDURXQGWRVTXDUHIRRW,IXVLQJ WKHNÀJXUHWKDWZRXOGSXWRXUIHHDURXQGWRSHUVTXDUHIRRWZHOO RYHUWKHDOORZDEOHVWDWHDLGUHLPEXUVDEOHÀJXUH,IWKHVWDWHUHLPEXUVHPHQWLVIRU WKHHQWLUHIDFLOLW\WKHQWKHVTXDUHIRRWDJHLQFUHDVHVDQGRXUIHHVWUXFWXUHZRXOG IDOOLQOLQHZLWKWKHDOORZDEOHUHLPEXUVHPHQW 8QGHUVWDQGLQJWKDWWKLVLVWHUPFRQWUDFWDQGWKDWSURMHFWVFRSHLVQRWNQRZQDWWKLV WLPHWKHIHHVWUXFWXUHLVQHJRWLDEOH :HKDYHIRXQGWKDWRXUWLPHIRUDQRUPDOVWXG\DVRXWOLQHGLQWKHVFRSHRIZRUN W\SLFDOO\UXQVDURXQGKRXUV7KDWLQFOXGHVWUDYHOWLPHÀHOGLQYHVWLJDWLRQWZR PHHWLQJVDQGSXOOLQJWRJHWKHUWKHLQIRUPDWLRQIRUWKHÀQDOUHSRUW 2XUVWDQGDUGKRXUO\ELOODEOHUDWHVDUHDVIROORZV 3ULQFLSOH'HVLJQHUKRXU 'UDIWLQJ'HVLJQHUKRXU 2IÀFH&OHULFDOKRXU www.TrautmanAssociates.com Description of Services *LYHQWKHDQWLFLSDWHGORFDWLRQRIWKHVHSURMHFWVLQ:HVWHUQ1HZ<RUNUHLPEXUVDEOH H[SHQVHVZRXOGEHLQFOXGHGZLWKRXUVWDQGDUGIHH 1RWHWKDW5RWK&RQVXOWLQJ*URXS,QFLVDGHVLJQSODQQLQJÀUPDQGGRHVQRWUHYLHZ RU PDNH UHFRPPHQGDWLRQV UHODWLQJ WR WKH IRRGVHUYLFH RSHUDWLRQV PDQDJHPHQW RI WKH IDFLOLW\ :H ZLOO ORRN WR DQG ZRUN ZLWK WKH 'LVWULFWV )RRGVHUYLFH 2SHUDWLRQ Management team for all operational recommendations. www.TrautmanAssociates.com Project Scope The scope of the project is fully defined in section 5G Description of Service. Below is an estimated timeline of these tasks for a single district building, shown for both Basic and Enhanced. The time scheduled for these activities is directly related to the studies that are selected. The 5-year long-range plan would be completed 2 weeks after the completion of the BCS for each building. All additional “study” or enhanced survey items will be complete within 3 weeks of the completion of the BCS. Final input of the BCS into the State web-site will be complete within 2 weeks of the completion of the BCS or per the State’s directive on web availability. www.TrautmanAssociates.com Section 6 Section 7 CERTIFICATE OF LIABILITY DATE INSURANCE (MM/DD/YYYY) 05/06/2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Amy Weimer NAME: PHONE (A/C, No, Ext): (716) 662-6166 E-MAIL amy@wolfagency.com ADDRESS: Phone: (716) 662-6166 Fax: (716) 662-1880 WOLF AGENCY INC 5820 BIG TREE RD ORCHARD PARK NY 14127 FAX (A/C, No): (716) 662-1880 INSURER(S) AFFORDING COVERAGE INSURED TRAUTMAN KING MARKWART ASSOCIATES P C DBA TRAUTMAN ASSOCIATES 470 FRANKLIN ST BUFFALO NY 14202 NAIC # INSURER A : Trumbull Insurance Company 27120 INSURER B : Hartford Fire Insurance Co 19682 INSURER C : INSURER D: INSURER E : INSURER F : CERTIFICATE NUMBER: 29092 COVERAGES REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR A ADD'L SUBR INSR WVD TYPE OF INSURANCE GENERAL X X LIABILITY POLICY NUMBER POLICY EFF (MM/DD/YYYY) POLICY EXP (MM/DD/YYYY) 01SBAKC1924 01/01/14 01/01/15 COMMERCIAL GENERAL LIABILITY X CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: PROPOLICY X JECT LOC A AUTOMOBILE X X UMBRELLA X $ DAMAGE TO RENTED PREMISES (Ea occurence) $ MED. EXP (Any one person) $ PERSONAL & ADV INJURY $ GENERAL AGGREGATE $ PRODUCTS - COMP/OP AGG $ COMBINED SINGLE LIMIT (Ea accident) $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (per accident) $ 1,000,000 300,000 10,000 1,000,000 2,000,000 2,000,000 $ 01SBAKC1924 LIABILITY ANY AUTO ALL OWNED AUTOS HIRED AUTOS LIMITS EACH OCCURRENCE 01/01/14 01/01/15 SCHEDULED AUTOS NON-OWNED AUTOS 1,000,000 $ A EXCESS DED B LIAB X LIAB X 01SBAKC1924 OCCUR 01/01/14 01/01/15 CLAIMS-MADE RETENTION $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory in NH) If yes, describe under DESCRIPTION OF OPERATIONS below EACH OCCURRENCE $ AGGREGATE $ 10,000 $ 01WECPG1631 01/01/14 01/01/15 Y/N N 10,000,000 10,000,000 N/A OTH ER $ E.L. EACH ACCIDENT $ E.L. DISEASE-EA EMPLOYEE $ E.L. DISEASE-POLICY LIMIT $ X WC STATUTORY LIMITS 1,000,000 1,000,000 1,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedule, if more space is required) **C105.2 & DB120.1 Certificates of Insurance Attached** Erie 1 BOCES is an additional insured on the general liability coverage if required by written agreement with the insured (as per form #SS0008 4/05). 30 days notice of cancellation applies to the certificate holder (10 days notice of cancellation for non-payment of premium) if required by written agreement with the insured (as per form #SS1223 6/11 & #WC990394). CERTIFICATE HOLDER CANCELLATION Erie 1 BOCES 355 Harlem Rd West Seneca NY 14224 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Attention: Amy H Weimer, Customer Service ACORD 25 (2010/05) © 1988-2010 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD DATE (MM/DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE 5/6/2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CONTACT Jennifer Dissette NAME: FAX PHONE (A/C, No): (716)633-8429 (A/C, No, Ext): (716)633-8401 E-MAIL ADDRESS: jdissette@promarkinsurance.com PRODUCER Promark Associated Agencies, Inc. 6470 Main St., Ste #2 PO Box 530 Williamsville NY 14231-0530 INSURER(S) AFFORDING COVERAGE NAIC # One Beacon Insurance Company 21970 INSURER A : INSURED INSURER B : Trautman King Markwart Assoc. 470 Franklin St INSURER C : INSURER D : INSURER E : Buffalo NY 14202 INSURER F : CERTIFICATE NUMBER:CL1412400475 COVERAGES REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR ADDL SUBR INSR WVD TYPE OF INSURANCE POLICY NUMBER POLICY EFF POLICY EXP (MM/DD/YYYY) (MM/DD/YYYY) GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR LIMITS EACH OCCURRENCE DAMAGE TO RENTED PREMISES (Ea occurrence) $ MED EXP (Any one person) $ $ PERSONAL & ADV INJURY $ GENERAL AGGREGATE $ GEN'L AGGREGATE LIMIT APPLIES PER: PROPOLICY LOC JECT PRODUCTS - COMP/OP AGG $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT (Ea accident) $ BODILY INJURY (Per person) $ ANY AUTO ALL OWNED AUTOS HIRED AUTOS $ SCHEDULED AUTOS NON-OWNED AUTOS BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ $ DED RETENTION $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE N/A OFFICER/MEMBER EXCLUDED? (Mandatory in NH) If yes, describe under DESCRIPTION OF OPERATIONS below A Professional Liability WC STATUTORY LIMITS OTHER E.L. EACH ACCIDENT $ E.L. DISEASE - EA EMPLOYEE $ E.L. DISEASE - POLICY LIMIT DPL-3135-14 2/1/2014 2/1/2015 per claim aggregate $ 2,000,000 2,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedule, if more space is required) Professional Liability limits shown are per claim and aggregate for all projects of the named insured. 30 day notice of cancellation applies. CERTIFICATE HOLDER Erie 1 BOCES 355 Harlem Road West Seneca, NY CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 14224 AUTHORIZED REPRESENTATIVE C Alderson/JCSTNZ ACORD 25 (2010/05) INS025 (201005).01 © 1988-2010 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD STATE OF NEW YORK WORKER'S COMPENSATION BOARD CERTIFICATE OF INSURANCE COVERAGE UNDER THE NYS DISABILITY BENEFITS LAW PART 1.To be completed by Disability Benefits Carrier or Licensed Insurance Agent of that Carrier 1a. Legal Name and Address of Insured (Use street address only) TRAUTMAN KING MARKWART ASSOCIATES, PC DBA TRAUTMAN ASSOCIATES 1b. Business Telephone Number of Insured 716-883-4400 1c. NYS Unemployment Insurance Employer Registration Number of Insured 7341824 470 FRANKLIN STREET BUFFALO, NY 14202 1d. Federal Employer Identification Number of Insured or Social Security Number 161137303 2. Name and Address of the Entity requesting Proof of Coverage (Entity being listed as the Certificate Holder) Erie 1 BOCES 3a. Name of Insurance Carrier The First Rehabilitation Life Insurance Company of America 3b. Policy Number of Entity listed in box "1a": 355 Harlem Rd DBL370110 3c. Policy effective period: West Seneca NY 14224 01/01/2014 to 12/31/2014 4. Policy covers: a. ✔ b. All of the employer's employees eligible under the New York Disability Benefits Law Only the following class or classes of the employer's employees: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability Benefits insurance coverage as described above. 5/6/2014 Date Signed By (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Title Chief Executive Officer IMPORTANT: If box "4a" is checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier, this certificate is COMPLETE. Mail it directly to the certificate holder. If box "4b" is checked, this certificate is NOT COMPLETE for the purposes of Section 220, Subd. 8 of the Disability Benefits Law. It must be mailed for completion to the Worker's Compensation Board, DB Plans Acceptance Unit, 20 Park Street, Albany, NY 12207. PART 2. To be completed by NYS Worker's Compensation Board (Only if box "4b" of Part 1 has been checked) State of New York Worker's Compensation Board According to information maintained by the NYS Worker's Compensation Board, the above-named employer has complied with the NYS Disability Benefits Law with respect to all of his/her employees. Date Signed By (Signature of NYS Worker's Compensation Board Employee) Telephone Number Title Please Note: Only insurance carriers licensed to write NYS Disability Benefits insurance policies and NYS Licensed Insurance Agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (5-06) Additional Instructions for Form DB-120.1 By signing this form, the insurance carrier identified in Box "3" on this form is certifying that it is insuring the business referenced in Box "1a" for disability benefits under the New York State Disability Benefits Law. The insurance carrier or its licensed agent will send this Certificate of Insurance to the entity listed as the certificate holder in Box "2". This certificate is valid for the earlier of one year after this form is approved by the insurance carrier or its licensed agent, or the policy expiration date listed in Box "3c". Please Note: Upon the cancellation of the disability benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder, the business must provide that certificate holder with a new Certificate of NYS Disability Benefits Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Disability Benefits Law. DISABILITY BENEFITS LAW Section 220. Subd. 8 (a) The head of state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and notwithstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b) The head of state or municipal department, board, commission, or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article, and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits for all employees has been secured as provided by this article. DB-120.1 (5-06) Reverse