product catalogue
Transcription
product catalogue
product catalogue Camfil Farr Air Filter Products and Services Air Filtration Solutions Camfil Farr – clean air solutions Dear Customers, I am pleased to present to you this latest edition of the Camfil Farr air filter solutions catalogue. We have made every effort to make it more practical and fully comprehensive. We are also making it available to you in the form of the enclosed CD-Rom. The catalogue contains up to date information and technical performance data on our range of air filtration products. This issue also contains summary information of the various test standards that need to be considered when making your selection. We have also included an application guideline section which will enable you to quickly identify the correct air filter for your application. All HEPA filters are individually tested to EN 1822 Camfil Farr are the world leader in providing air filtration solutions and the product range includes many world class benchmark filters. In addition to providing a comprehensive range of quality products, we at Camfil Farr believe that service is of paramount importance. In today’s fast moving industries the ability to get goods to where they are needed quickly and correctly is vital. To ensure that our “right first time” service matches our “best in class” products we are developing our logistics and expanding our fleet of dedicated delivery vehicles. This unique service will ensure that your goods arrive where you want them, when you want them. Finally, I would strongly recommend that you visit the www.camilfarr.co.uk website where you can access much more detailed information about our products and services, and the latest news on our “CLEAN AIR SOLUTIONS”. Enjoy your reading Bill Wilkinson Managing Director 62 Bd de Advanced fabrication capability K RL APE : 748 ANY SC - Code COMP 363 460 ATION is B 393 RTIFIC NT CE RCS Par EUROVE is FRANCE 03 Par iploma ation D l 750 astopo Certific Séb N° : 34 07.01.3 fies that ny certi Compa fication 5-F9 Class F Filters Fine Air from P GROU FARR d at eden CAMFIL NT Certi EUROVE igatan Industr en have be Locate OSA Sw 933 TR 3 , 61 me Trade na Camfil The list OM ucts is fied prod of certi ht is author d standar 6 -11-200 d at : displaye m tion.co certifica ovent- w.eur tp://ww use ised to llowing ts of fo iremen the requ cording ed ac assess P ce GROU cordan L FARR ark in ac CAMFI ation m anual Certific M ROVENT e Operational the EU in th d 06 ifie 20 spec OM-11- IST s BENO Jacque certification r of Directo : al date Approv : cked on Re-che til : Valid un rules with the 31/01/07 31/12/07 31/03/09 Comprehensive stocks backed by integrated inhouse logistics CityFlo ............................................................ 62 CityCarb® .......................................................... 63 CitySorb ............................................................ 64 Camcarb Green ................................................... 65 Camcarb Mounting Frames ................................... 66 Camsure ............................................................ 67 Hi-Flo® M-Series .................................................29 Hi-Flo® P, PL-Series ...........................................30 Hi-Flo® U-Series .................................................31 Hi-Flo® A-Series .................................................32 Hi-Flo® T-Series .................................................33 S-Flo W P Series ..................................................34 S-Flo W U Series .................................................35 S-Flo W A Series ..................................................36 Opakfil Green ......................................................37 Ecopleat & Ecopleat MCTA ...................................38 Riga-Flo ............................................................39 OpakAir ............................................................40 Airopac® ............................................................41 Filter Frames and Housings Sofilair - H10 to H14 ...........................................45 Sofilair Green ......................................................46 Close Pleat - H13 ................................................47 Opakfil G Micretain - H10 ....................................48 Megalam MD, MX, MG .........................................49 Megalam MX & MG - H14 ....................................50 Megalam MD - H10 & H14 ...................................51 Megalam MD & MG - U15 ....................................52 Megalam (Laminator) MDL & MXL - U15 & U16 .....53 Silent Hood Diffuser - H14 ...................................54 Megalam U (Gel) - H14 & U15 .............................55 Megalam T (Gel) - H14 & U15 ..............................56 Megalam MD & MX e-PTFE - U15 .........................57 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 1 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. HEPA / ULPA Filters, Class H10 to U17 Absolute Filter Holding Frame .............................. 70 Type 8 - Filter Holding Frame ............................... 71 FCB-P ............................................................ 72 FCBS-HF ............................................................ 73 FCBS-A ............................................................ 74 FCBL-CC ............................................................ 75 FCBL-CS ............................................................ 76 FCBL-HF ............................................................ 77 Pharmaseal ......................................................... 78 Camsafe ............................................................ 79 Termikfil 2000 ................................................... 80 Absolute® 1FRK ................................................. 81 Paint Extract Filters ............................................. 82 Airopac® HT-HF ................................................. 83 Panolair SSI - Micretain H10 ............................... 84 CDM Media ........................................................ 85 Cam GT® ........................................................... 86 Campulse EF ...................................................... 87 Hi-Flo® T ........................................................... 88 Gold Series ......................................................... 89 HemiPleat Cartridges ........................................... 90 Carbon and Chemical Filters Bag and Compact Filters, Class F5 to F9 Housings, frames & special applications Camfil Farr Solutions 30/30 ............................................................18 Aeropleat PP .......................................................19 Camglass GP .......................................................20 Pad Holding Frame ..............................................21 EcoFlo ............................................................22 Cam Glass Media .................................................23 Synthetic Media Rolls ..........................................24 Fan Coil Filter .....................................................25 Hi-Cap® 30P, 40P, 50P ......................................26 Pre-Filtration, Class G3 to F5 Carbon and Chemical Filters Bag and Compact Filters, Class F5 to F9 Pre-Filtration, Class G3 to F5 H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Index - Camfil Farr Camfil Farr Solutions Quick Selection Guide Air Filter Selection Filter Grade EN 779:2002 Primary Filters Primary Filtration Medium Efficiency Primary Filters G2 ≥ 65% G3 ≥ 80% G4 ≥ 90% EN 779:2002 Average Arrestance EN 779:2002 Fine Filters High Efficiency F5 ≥ 40% F6 ≥ 60% F7 ≥ 80% F8 ≥ 90% F9 ≥ 95% MPPS (Most Penetrating Particle Size) ≥ 95% H10 ≥ 85% ≥ 99,9% H11 ≥ 95% ≥ 99,97% H12 ≥ 99,5% H13 ≥ 99,95% H14 ≥ 99,995% U15 ≥ 99,9995% U16 ≥ 99,99995% U17 ≥ 99,999995% ≥ 99,99% ULPA ≥ 99,999% CityFlo, CitySorb, CityCarb, Camcarb Filter Housings, Camseal, FC Casings, Type 8 Frames etc. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 2 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. DOP 0,3 um EN 1822 HEPA EN 779:2002 Average Efficiency Very High Efficiency 100 000 10 000 100 to 1000 1 to 10 Class according to Fed. Std 209 E Filter Holding Frames and Casings Molecular Final Filters / Clean Room Filters Filtration for Air Conditioning Systems. Pre-Filtration for HEPA/ ULPA Filters Fine Filters Camfil Farr Solutions Camfil Farr Solutions Services Filter installation upgrade service Before After In addition to providing up to date air filtration solutions Camfil Farr can provide a structured training program covering all aspects of air filtration engineering. Adapted to suit your needs the training includes information on how to specify and select air filters, air filter standards, indoor air quality legislation, air filter application, and reducing energy and environmental impact. Pre-Filtration, Class G3 to F5 Become the air filtration specialist in your company Air filter system validation service By fitting energy efficient filters and maintaining ventilation systems real energy savings can be made quickly. Maintained correctly these will translate into long lasting real reductions in cost and environmental impact. Camfil can provide a comprehensive package of air hygiene services that will ensure your systems are healthy, legislation compliant, and cost effective. Bag and Compact Filters, Class F5 to F9 Camfil Academy: Performance Managed Supply Camfil complete the “cradle to grave” responsibility for all your filtration needs by providing a unique logistics system at the centre of which is a national transport fleet. This dedicated fleet of vehicles with trained employees ensures that you get your goods when and where you need them. To complete the service, we can remove and dispose of used filters together with providing all of the required certification. Filter Frames and Housings Ensuring safe and efficient running of effective air filtration systems demands a multi-disciplined service solution. These extend beyond comprehensive logistics to ensuring that filters are fitted correctly, working efficiently, and optimised to reduce the overall cost of ownership for the lifetime of the installation. In order to comply with current legislation and reduce cost of ownership of some installations, upgrading work is required. Camfil can provide a joined up solution which includes selection, supply, fitting, commissioning and validation of any new or upgraded installations. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 3 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Camfil has a fresh approach to managing on-site air filtration services. We understand that filtration is required for protecting people’s health, ensuring legislative compliance and protecting valuable investments. We have our own site service team that can manage all aspects of your air filter requirements by offering a wholly inclusive service package. Carbon and Chemical Filters Camfil Filter Management H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Camfil On-Site Expertise: Camfil Farr Solutions Caring for the Environment “How will your filters help you to reduce the environmental impact of your installations?” Camfil has been involved in air quality for over 40 years, and has to set an example when it comes to the environment. It therefore has an obligation to provide its customers with practical assistance on green issues. With regard to complying with the law on waste disposal, Camfil is with you all the way; in designing products and services, Camfil shares your environmental concerns. It is now widely acknowledged that air conditioning filters can be considered ordinary industrial waste, whereas filters used in environments containing potentially hazardous products (e.g. return air from clean rooms, spray booths and operating theatres) should be considered special industrial waste and must be disposed of by an approved route using accredited systems. Please Note - your individual circumstances depend entirely on your processes and we recommend that you approach your usual waste disposal provider, who will be qualified to advise you on the matter. Follow up CFM Conscious of the increasing importance attached by our customers to waste management, Camfil can support you and take charge of replacing and organising the disposal of certain used filters as part of its CAMFIL FILTER MANAGEMENT (CFM) programme. For more information and to find out whether this service might work for you, please contact us. In order to minimise waste, Camfil pay close attention to the life cycle of the product: 1. We make strenuous efforts to extend the lifespan of our filters and to optimise their performance, which means that you reduce your operating costs, the frequency with which you have to replace the filters and the cost of their disposal. Just look at the large filter surface used in many of our products and remember large filter area is synonymous with long filter life. 2. We favour the use of recyclable or incinerable materials. 4. The Green CAMFIL range ensures that you can dispose of your used filters with less hassle and at lower cost. The use of plastics or cardboard lends itself to the incineration of used filters whilst ensuring compliance with all provisions of environmental law. 5. We minimise the weight of materials used in the construction of our filters which helps reduce the waste mass as far as possible when the filter reaches the end of its life. 6. In our ISO 14001 certified factories, we are phasing out the use of chloride solvents and hazardous products from our processes. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 4 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. 3. We are continually researching effective materials with low pressure loss, a parameter that has a direct influence on the energy consumed during the lifetime of the filter. 70% of the total cost comes from energy costs Calculations show that energy normally accounts for 70% of the total cost of the life cycle of an air treatment system. Energy consumption is in direct proportion to the filter’s average pressure loss. 100 80 60 40 2 Bag and Compact Filters, Class F5 to F9 En y erg 20 5 % t t t t t Cos r Cos g Cos r Cos l Cos u a e n s t o i l o b i n p F a La Dis Cle Choosing the right filter saves energy H E PA / U L PA F i l t e r s , C l a s s H10 to U17 In order to optimise the lifespan of the filter and to reduce energy consumption, it is important to bear in mind the extent to which their configuration and their structure influence the average pressure loss. Tapered pockets Parallel pockets As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Blocked surface = high energy consumption Software aimed at helping select the right filter = optimising energy costs Typical pressure loss (Pa) in a ventilation system with 2 stage filtration 1Pa = 1 euro A rule of thumb, for a typical installation running for half of the time over one year, is that one additional Pascal in pressure drop adds 1 euro per filter in extra energy cost. For over 40 years, Camfil Farr has played a pioneering role in designing filters with low average pressure loss for all efficiency levels for air conditioning and ventilation systems. Camfil Farr was the first filter manufacturer to develop sophisticated software that calculates the overall cost for the complete life cycle of air filters. As part of our continuous improvement, this software has evolved over time and it uses real life data collected from numerous tests in real use conditions. This enables us to calculate the pressure loss of the filter and its actual lifespan, rather than relying on theoretical calculations. For more information and assistance, please contact your nearest branch of Camfil Farr. A badly designed filter construction could add 50 Pascal compared to a well engineered filter, even if it claims to have the same efficiency. In other words it adds 50 euros to the annual energy bill, for every filter. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 5 Carbon and Chemical Filters The price of crude oil has more than doubled in recent years and the cost of electricity is rising throughout the world. The World Bank’s Energy Group has predicted that total energy consumption is set to rise at the current rate for at least the next 50 years. The cost of ventilation Ventilating buildings, as we know, can be a very expensive business. The average energy cost of filters is around 30% of the total costs of the system. By choosing the right filter, for example the F7 for its efficiency and its very low average pressure loss, energy savings can be made whilst maintaining a high level of IAQ. When you consider that the air filter is the most inexpensive and simplest component to change, savings can be made quickly. 8 Filter Frames and Housings 15 Economic optimisation of air filtration A i r F i l t e r Te c h n o l o g y 70 Camfil Farr Solutions Would you like to reduce your energy outgoings? Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Camfil Farr Solutions Energy & Air Quality Rating The newly developed Energy & Air Quality Rating makes it easy to reduce energy consumption and at the same time, it guarantees the air quality. These two critical factors were taken into consideration during the development of our new classification system. If a filter achieves a good grade, it is because it cuts costs and makes the air clean. It’s as simple as that. Honestly, how did you choose filters before? Selecting the correct air filter has never been easy but the Energy & Air Quality Rating changes that. Using the rating system, it’s easy to choose the right air filter for your needs. It’s important however, to be aware that an A-filter is not always the right choice for you. The top rating may be appropriate for a medical or food application where the demand for air quality is critical. Conversely, a G-filter may be the best choice for a lowgrade storeroom. Whatever your budget and your requirement for air quality, there will be a rating letter to meet your needs. The selection process will be both easy and precise. It’s not just about new EU energy concepts, it’s about your grandchildren. The new and more stringent requirements aim to make your company more energy efficient but the most important aspect is much closer to home. At Camfil Farr, we are constantly striving to develop new technologies and methods that make us even more environmentally friendly. We want to give our children and our grandchildren the opportunity to grow up in a clean environment. At the end of the day, that’s what matters most. This symbol will speak volumes in your annual report. cases we have seen that air filters may be responsible for as much as 30 percent of the total energy consumption in an air-handling unit. Consequently, there is substantial profit to be made by choosing wisely. The Energy & Air Quality Rating helps you control your energy consumption. That will save you money. Actually, a lot of money. Why one of the leading filter companies cares. We believe in transparency and honesty. The filter industry is clouded by numbers and figures, making it virtually impossible to compare different filters. We want to clean up the mess. Surely, the customer will profit from having all the facts when deciding which filter to choose. We believe that the industry itself will benefit from a common standard, since it puts pressure on developers to make energy efficient filters. When a company develops an excellent filter, we think it should be rewarded with an “A”. Objectively tested. Filter efficiency in actual use was an essential parameter when developing the Energy & Air Quality Rating. To guarantee independent verification of the discharged efficiency value, we collaborated with the Technical Research Institute of Sweden (SP) - a leading organisation in the development of sustainable energy and environmental technology in Europe. The data was obtained through long-term measurements, performed under realistic conditions. As you can see, the advantages are obvious. Well, maybe not crystal clear. Differentiating air filters is a complex matter. Many variables impact a comparison study, and not all are selfevident. Laboratory tests are made under controlled conditions and test protocols are an imperfect compromise of actual conditions. In actual use, most air filters will remain in a system for months or even years. During that time, an air filter will see hundreds of environmental changes such as temperature, humidity, airflow velocity and particle load. Add to this the fact that it is not impossible for suppliers to manipulate observations or data to best suit their needs. With the Energy & Air Quality Rating all you really need to look at is a single letter. All in all, we like to think the advantages are quite obvious. The cost of energy is at an all-time high and will continue to increase. It has never been more important to strive for energy efficiency. In some Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 6 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. We have made choosing filters as easy as ABC. Indoor Air Quality (IAQ) Atmospheric pollution can be categorised in two different ways. The simplest is measurement (a physical categorisation) to distinguish gaseous pollutants from solid, dust and particulate pollutants. The second is based on the origin of pollutants and is divided into primary and secondary pollutants. Solid pollutants usually in the form of small (fine) particles are very important and from a cleanliness point of view, these particles deserve particular attention. These are capable of acting as vectors to other substances, such as carcinogenic polycyclic aromatic hydrocarbons, which is particularly worrying given the capacity of the finest particles (< 1μm) to find their way into the lungs and even to penetrate into the bloodstream. Effective solutions aimed at combating such particle pollution are now widely known. The development of the main standards and recommendations governing the manufacture and use of modern air filters is clearly geared towards much higher filtration levels than have been permitted in the past Primary pollutants City Primary pollutants are substances present in the atmosphere, in the form in which they are emitted. Of these pollutants, some are especially prominent: Sulphur dioxide (SO2) emitted by certain industrial processes, such as paper-making and refining, and in particular by the use of sulphurous fossil fuels. SO2 is one of the main causes of acid rain on account of its transformation in the atmosphere into sulphuric acid (H2 SO4). Nitric oxides (NOX), and in particular nitrogen dioxide (NO2), which is usually emitted from the burning of fossil fuels (particularly vehicles), contribute towards the formation of ozone in the atmosphere. Polycyclic aromatic Our range of ‘CITY’ filters has been developed with the sole purpose of combating atmospheric pollution and its major components. As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Atmospheric pollution CITYCARB and CITYFLO combine particulate filtration with pollution and odour filtration. They are suitable for any new installation and can be readily installed to upgrade and improve systems currently equipped with standard filters. With its higher molecular adsorption, CITYSORB is ideal for highly polluted urban environments. CITYSORB must be fitted in conjunction with a particulate filter above F7 efficiency, HIFLO or OPAKFIL type. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 7 Bag and Compact Filters, Class F5 to F9 Pre-Filtration, Class G3 to F5 Solid pollutants H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Secondary pollutants are substances whose presence in the atmosphere is the result of chemical transformations related to the interaction of compounds known as precursors. Ozone is the main secondary pollutant, it is formed as a result of a photochemical process in the presence of certain primary pollutants (carbon monoxide, nitric oxide and volatile organic compounds). This is a gas that is naturally present in the atmosphere in low concentrations at high altitude. At low altitude, on the other hand, the development of the concentration is primarily the result of human activity. Sulphuric acid and nitric acid form in the atmosphere as a result of humidity from sulphur dioxide and nitric oxide respectively. Carbon and Chemical Filters . Secondary pollutants Filter Frames and Housings Environmental health is becoming a central concern at national and international levels. Indoor Air Quality (IAQ) is an area that focuses on providing a comfortable and healthy indoor environment which is important to the well being of people. We spend 80% of our time in indoor spaces and, as such, the issue of IAQ is a key aspect of public health, especially since this affects the entire population, particularly the most sensitive and vulnerable. The industrialised world is a very different place compared to 50 years ago and one major difference is that the air we breathe is now more heavily and more diversely polluted than at any time in the past. Although natural sources of pollution exist, the greater concerns arise as a result of mans own activities which have increased both the amount and the complexity of pollutants found in the atmosphere. There are tens of thousands of synthetic chemicals (not found in nature) made today with an estimated annual production rate in excess of a billion tonnes. These chemicals are released to the atmosphere during manufacture use and can subsequently travel vast distances. They are an inevitable part of our lives hydrocarbons are emitted by the incomplete burning of fuels or carbon, which can usually be found in the air, linked to particles. Some of them are known to be highly carcinogenic. A i r F i l t e r Te c h n o l o g y Environmental Health Camfil Farr Solutions Camfil Farr Solutions Camfil Farr Solutions AT E X ATEX Directive: Explosive atmospheres Two important new safety directives have entered into force in Europe. These new regulations come under the title of ATEX Directives and apply to manufacturers, suppliers and users of equipment intended for use in potentially explosive atmospheres (dangerous areas). An explosive atmosphere is defined as a mixture with air, under atmospheric conditions, of hazardous substances in the form of gases, vapours, mists or dusts in which, after ignition has occurred, combustion spreads to the entire unburned mixture. The 99/92/EC (ATEX 137) Directive, known as the ‘User Directive’ requires employers to protect their employees from the risks posed by explosive atmospheres. The 94/9/ EC (ATEX 95 or ATEX 100A) Directive on ‘Equipment and protective systems intended for use in potentially explosive atmospheres’ covers electrical and non-electrical products intended for use in hazardous places (gases, vapours, mists). Conformity with the ATEX Directives has been a legal requirement in all EU Member States since 1 July 2003. In Gas Dust Areas 0 20 1 2 21 22 biopharmaceutical applications, some procedures must use ATEXclassified filters in certain places (please see table). Camfil Farr in Europe has developed HEPA filters and ATEX accredited housings for use in biopharmaceutical installations in order to prevent electrostatic dangers caused by gas or dust in an ATEX area. Camfil Farr has developed specific versions of ATEX for most filters and housings used in biopharmaceutical installations in order to prevent electrostatic dangers caused by gas or dust in an ATEX area. Camfil Farr’s ATEX solutions are entirely certified in accordance with the requirements of the ATEX Directives with the appropriate EX marking, the ATEX conformity statement and the instructions for use. Key to the table: Definition of ATEX areas and corresponding product categories. Definitions of areas Definitions Place where an explosive atmosphere is permanently present Category ATEX Typical suitability of place 1G Equipment adapted to 0 areas 1D Equipment adapted to 20 areas Place where an explosive atmosphere is probable occasionally under normal operating conditions 2G Equipment adapted to 1 areas 2D Equipment adapted to 21 areas Place where an explosive atmosphere is improbable under normal operating conditions, but, where applicable, only lasts a short time. 3G Equipment adapted to 2 areas 3D Equipment adapted to 22 areas All Camfil Farr ATEX air filtering solutions Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 8 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. All Camfil Farr ATEX air filtering solutions are certified for use in explosive gas atmospheres (Classes 1 and 2) and explosive dust atmospheres (Classes 21 and 22). They comply with European Standard EN 13463-2001 Annex C Non-electrical equipment for potentially explosive atmospheres, as attested by the conformity statement attached to these products. Concerns over public health have resulted in increased awareness about indoor air quality (IAQ). We now spend approximately 80% of our time in indoor spaces and legislation now requires that these spaces are comfortable, safe and without risk to health. Camfil Farr filters for air conditioning systems help to safeguard human health by preventing airborne contamination from entering these environments. In addition correctly selected and maintained air filters keep air conditioning systems clean ensuring that they perform in accordance with design parameters. Camfil Farr’s extensive range of comfort air filters, are typically used in offices, schools and shopping centres etc. 1, 2, 6, 7 or 8 5 or 9 1, 2, 3, 4, 5 or 6 5 5 5 or 9 Bag and Compact Filters, Class F5 to F9 1, 2, 6, 7 or 8 3 or 4 5 3, 10 H E PA / U L PA F i l t e r s , C l a s s H10 to U17 5 3. Citycarb 6. S-Flo 7. Hi-Cap 8. 30/30 4. City-Flo 9. Fan Coil Filter 5. Ecopleat Filter Frames and Housings 2. Opakfil Green 10. Eco-Flo Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 9 A i r F i l t e r Te c h n o l o g y 1. Hi-Flo Carbon and Chemical Filters IAQ recommendations As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Camfil Farr Solutions Public Buildings Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Camfil Farr Solutions Hospitals and Healthcare Nowhere is air filtration more important than in health care facilities. Air filters offer excellent protection from airborne diseases in health care facilities, provided that they form part of an overall air quality control programme. Camfil Farr provides a comprehensive solution that ensures the provision of this quality. Our extensive scope of supply ranges from providing air filters to satisfy the most demanding standards, air filter housings, system validation and monitoring, filter management, and specialist consultancy services. Our products provide safe and comfortable environments for patients, visitors and healthcare professionals. 1 2 3, 4 5, 6 5, 6 6, 8 7, 9 7, 9 1. Hi-Flo F7 2. Opakfil Green F8 3. Sofilair H13 6. Megalam MDA 7. Ecopleat 8. CamHOSP2 details on request 4. FC-Filter Casing 9. Sofdistri Exhaust Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 10 5. Sofdistri As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Hospital and Healthcare recommendations Pharmaceutical Industry 4, 5 8, 11 Bag and Compact Filters, Class F5 to F9 7, 8, 9, 10 3, 11, 15 H E PA / U L PA F i l t e r s , C l a s s H10 to U17 3, 12, 13 3, 14 1. Hi-Flo F7 2. Opakfil Green F7 3. Sofilair H13 6. Pharmaseal 7. Softdistri 8. Megalam MD 11. Sofdistri Exhaust 12. Camsafe 13. Airopac/Opakair 4. CamGrid 9. Softdistri Polyester 14. FC - Filter Casing Carbon and Chemical Filters As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Pharmaceutical Industry recommendations 5. Megalam T "U" 10. Megalam Green 15. Ecopleat F6 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 11 Filter Frames and Housings 6, 8 2 A i r F i l t e r Te c h n o l o g y 1 Pre-Filtration, Class G3 to F5 For more than forty years Camfil Farr has been a leading supplier of air filter products and services to the Bio-Pharma Industry. Many of our clients have multiple facilities located around the world. Camfil Farr is viewed by many of the largest pharmaceutical manufacturers as a partner and well positioned to support their air filtration demands on a local and global basis. Camfil Farr Solutions Camfil Farr Solutions Camfil Farr Solutions Food Industry Protecting human health is a major concern for governments throughout the world. In many countries agencies associated with food safety have the authority to take direct action against manufacturers who fail to ensure the safety of foodstuffs that they produce. To prevent the air conditioning system from becoming contaminated, temperature, humidity and cleanliness must be closely controlled. Talk with the experts in clean air solutions - Camfil Farr. 1, 2 3 3 4, 5 6, 7 8, 9, 10 1. Hi Flo F7 2. S-Flo F7 3. Opakfil F8 4. Sofilair H13 5. FC - Filter Casing 6. Sofdistri 7. Megalam 8. Sofdistri Exhaust 9. 30/30 10. Ecopleat Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 12 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Food Industry recommendations Automotive Industry 8, 9, 1, 2, 3 8, 9, 1, 2, 3 4 H E PA / U L PA F i l t e r s , C l a s s H10 to U17 5, 6 or 7 8, 9, 1, 2, 3 Bag and Compact Filters, Class F5 to F9 8, 9, 1, 2, 3 Pre-Filtration, Class G3 to F5 Few industrial applications demand such a clean working environment as painting facilities. Paint spraying facilities require a constant supply of fresh air for hygiene and safety reasons. We currently provide clean air and services to many major automotive plants throughout the world. We provide the best possible cost effective clean air solutions, customised and performance-optimised to meet your demands. Supplied and delivered exactly according to your needs – by Camfil Farr. 3. Opakfil 6. Panolair 7. Camgrid SM 20 8. 30/30 4. Airopac HT/Panolair HT 5. CDM-600 Filter Frames and Housings 2. S-Flo 9. Hi-Cap Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 13 A i r F i l t e r Te c h n o l o g y 1. Hi-Flo Carbon and Chemical Filters Automotive Industry recommendations As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Camfil Farr Solutions Camfil Farr Solutions Camfil Farr Solutions Microelectronic Industry Advanced production methods often require very clean air, and as technology advances these requirements look likely to increase. Camfil Farr is recognised as the leading supplier of high efficiency filtration products for the microelectronics industry. HEPA/ULPA filters are produced within controlled environments in our ISO 9000-certified plants and are individually tested and certifed to ensure compliance. Our large production capacity ensures the availability of our products at all times throughout the world. 1, 2 2, 3, 4 4, 5 7 1, 2 6 1, 2 or 3 8 6 2, 3, 4 4, 5 4, 5 1. Hi-Flo F7/F8 2. Opakfil Green F8/H10 3. Camcarb 6. Silent Hood 7. Megalam MX MG 8. Megalam U 4. Sofilair H13/H14 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 14 5. Gigapleat As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Microelectronic Industry recommendations Gas Turbines, Air Filters and Systems 1, 2, 3, 4, 5, 8 Pre-Filtration, Class G3 to F5 Camfil Farr provides systems solutions for the turbo machinery and power systems industry. Our solutions include filters, ducting, fans, silencers, and deicing. With more than 40 years of experience, Camfil Farr delivers value to customers worldwide whilst providing everyone with something essential clean air. Camfil Farr Solutions Camfil Farr Solutions H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Bag and Compact Filters, Class F5 to F9 6, 7 3. Hi-Cap 6. CamPulse EF 7. HemiPleat details on request 8. Camclose details on request 4. Ecopleat Carbon and Chemical Filters 2. Hi-Flo 5. Cam GT Filter Frames and Housings 1. 30/30 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 15 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Gas Turbine, Air Filters and System recommendations Camfil Farr Solutions Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 16 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Notes Camfil Farr Solutions Pre-Filtration, Class G3 to F5 Page 18 Page 19 Page 20 Page 21 Metal Panels EcoFlo Media Rolls Cam Glass Media Media Rolls Synthetic Media Rolls Fan Coil Filters Fan Coil Filter Page 22 Page 23 Page 24 Page 25 Pre-Filtration, Class G3 to F5 Pad Filters Pad Holding Frame Bag and Compact Filters, Class F5 to F9 Panel Filters Camglass GP H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Pleated Filters Aeropleat PP Carbon and Chemical Filters Pleated Filters 30/30 Primary Bag Filters Hi-Cap® 30P, 40P, 50P Filter Frames and Housings Page 26 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 17 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Summary Pre-Filtration, Class G3 to F5 Pre-Filtration, Class G3 to F5 Pleated Filters 30/30 EN 779:2002 DI IE D IN VI DU ALLY CER TI F W D • High mechanical strength • Large media surface • Fully supported media bonded • Unique radial pleat design onto a wire support grid • Rigid, water resistant cardboard frame • Bonded into case to eliminate air bypass Application: Primary filter for air conditioning systems. Type: High performance disposable pleated panel filter. Case: Rigid water resistant cardboard. Media: Mixture of cotton and synthetic fibre. EN 779:2002 efficiency: G4. Gravimetric efficiency: 92%. Eurovent 4/5 efficiency: EU4. Recommended final pressure drop: 250 Pa. Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. Reference Type Model Dimensions (WxHxD) mm Filter classification EN 779:2002 Air flow/ pressure drop m³/hr/Pa Media area m2 049880-927 30/30 Panel 30/30-12122NOM 305x305x50 G4 864/70 0,39 0,24 0,01 F 049880-006 30/30 Panel 30/30-12242NOM 305x610x50 G4 1710/70 0,79 0,40 0,01 F 049880-001 30/30 Panel 30/30-16202NOM 406x508x50 G4 1890/70 0,94 0,44 0,01 F 049880-004 30/30 Panel 30/30-16252NOM 406x635x50 G4 2340/70 1,18 0,55 0,02 F 049880-002 30/30 Panel 30/30-20202NOM 508x508x50 G4 2340/70 1,12 0,55 0,02 F 049880-012 30/30 Panel 30/30-20242NOM 508x610x50 G4 2880/70 1,36 0,66 0,02 F 049880-003 30/30 Panel 30/30-20252NOM 508x635x50 G4 2970/70 1,42 0,70 0,02 F 049880-005 30/30 Panel 30/30-24242NOM 610x610x50 G4 3420/70 1,64 0,78 0,02 F 059413-002 30/30 Panel 30/30-12244NOM 305x610x100 G4 2070/90 1,28 0,75 0,02 E 059413-004 30/30 Panel 30/30-16204NOM 406x508x100 G4 2250/90 1,45 0,85 0,02 E 059413-005 30/30 Panel 30/30-16254NOM 406x635x100 G4 2880/90 1,82 1,05 0,04 E 059413-003 30/30 Panel 30/30-20204NOM 508x508x100 G4 2880/90 1,73 1,05 0,04 E 059413-008 30/30 Panel 30/30-20244NOM 508x610x100 G4 3420/90 2,09 1,25 0,04 E 059413-006 30/30 Panel 30/30-20254NOM 508x635x100 G4 3600/90 2,18 1,30 0,04 E 059413-001 30/30 Panel 30/30-24244NOM 610x610x100 G4 4140/90 2,56 1,45 0,04 E 054862-010 30/30 Panel 30/30-12241NOM 305x610x25 G4 1310/65 0,42 0,25 0,01 G 054862-001 30/30 Panel 30/30-16201NOM 406x508x25 G4 1460/65 0,45 0,30 0,01 G 054862-004 30/30 Panel 30/30-16251NOM 406x635x25 G4 1840/65 0,57 0,35 0,01 G 054862-002 30/30 Panel 30/30-20201NOM 508x508x25 G4 1800/65 0,56 0,35 0,01 G 054862-933 30/30 Panel 30/30-20241NOM 508x610x25 G4 2200/65 0,68 0,40 0,01 G 054862-003 30/30 Panel 30/30-20251NOM 508x635x25 G4 2300/65 0,71 0,45 0,01 G 054862-005 30/30 Panel 30/30-24241NOM 610x610x25 G4 2600/65 0,83 0,50 0,01 G Other dimensions are available on request - All dimensions are nominal. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 18 Unit Unit weight volume Energy Rating kg m3 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. TIFICAT ER E C Advantages As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Type DU ALLY CER TI F W D Model • Bonded into case to eliminate onto a wire support grid air by-pass • Robust construction Application: Pre filter for comfort air conditioning applications. Type: Disposable pleated panel filter. Case: Moisture resistant cardboard. Media: Mixture of cotton and synthetic fibre. Gravimetric efficiency: 92%. EN 779:2002 efficiency: G4. Eurovent 4/5 efficiency: EU4. Recommended final pressure drop: 250 Pa. Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. Dimensions (WxHxD) mm Filter flow/pressure Media classification EN Airdrop m³/hr/Pa area m 2 779:2002 Unit weight kg Unit volume m3 Energy Rating PP12122NOM Aeropleat PP PP12122NOM 305x305x50 G4 820/70 0,26 0,20 0,01 G PP12242NOM Aeropleat PP PP12242NOM 305x610x50 G4 1620/70 0,53 0,35 0,01 G PP16202NOM Aeropleat PP PP16202NOM 406x508x50 G4 1830/70 0,63 0,40 0,01 G PP16252NOM Aeropleat PP PP16252NOM 406x635x50 G4 2300/70 0,79 0,50 0,02 G PP20202NOM Aeropleat PP PP20202NOM 508x508x50 G4 2290/70 0,75 0,50 0,02 G PP20242NOM Aeropleat PP PP20242NOM 508x610x50 G4 2750/70 0,91 0,55 0,02 G PP20252NOM Aeropleat PP PP20252NOM 508x635x50 G4 2880/70 0,95 0,60 0,02 G PP24242NOM Aeropleat PP PP24242NOM 610x610x50 G4 3240/70 1,10 0,65 0,02 G PP12244NOM Aeropleat PP PP12244NOM 305x610x100 G4 1640/55 0,85 0,65 0,02 G PP16204NOM Aeropleat PP PP16204NOM 406x508x100 G4 1830/55 0,96 0,75 0,02 G PP16254NOM Aeropleat PP PP16254NOM 406x635x100 G4 2300/55 1,20 0,90 0,04 G PP20204NOM Aeropleat PP PP20204NOM 508x508x100 G4 2290/55 1,15 0,90 0,04 G PP20244NOM Aeropleat PP PP20244NOM 508x610x100 G4 2750/55 1,38 1,05 0,04 G PP20254NOM Aeropleat PP PP20254NOM 508x635x100 G4 2880/55 1,44 1,10 0,04 G PP24244NOM Aeropleat PP PP24244NOM 610x610x100 G4 3240/55 1,70 1,20 0,04 G PP12241NOM Aeropleat PP PP12241NOM 305x610x25 G4 1310/75 0,28 0,25 0,01 G PP16201NOM Aeropleat PP PP16201NOM 406x508x25 G4 1460/75 0,31 0,25 0,01 G PP16251NOM Aeropleat PP PP16251NOM 406x635x25 G4 1840/75 0,39 0,30 0,01 G PP20201NOM Aeropleat PP PP20201NOM 508x508x25 G4 1800/75 0,38 0,30 0,01 G PP20241NOM Aeropleat PP PP20241NOM 508x610x25 G4 2200/75 0,46 0,35 0,01 G PP20251NOM Aeropleat PP PP20251NOM 508x635x25 G4 2300/75 0,48 0,40 0,01 G PP24241NOM Aeropleat PP PP24241NOM 610x610x25 G4 2600/75 0,55 0,45 0,01 G Carbon and Chemical Filters DI Reference IE D IN VI • Fully supported media bonded frame • Comprehensive range of standard and non standard sizes Filter Frames and Housings EN 779:2002 • Moisture resistant cardboard Other sizes are available on request - All dimensions are nominal. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 19 A i r F i l t e r Te c h n o l o g y TIFICAT ER E C Advantages Bag and Compact Filters, Class F5 to F9 Aeropleat PP H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Pleated Filters Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Pre-Filtration, Class G3 to F5 Pre-Filtration, Class G3 to F5 Panel Filters Camglass GP Advantages • Robust construction • Moisture resistant cardboard frame • Comprehensive range of EN 779:2002 DI IE D IN VI DU ALLY CER TI F W D • Gradual density media to improve dust holding capacity Application: Pre filter for comfort air conditioning applications. Type: Disposable panel filter. Case: Moisture resistant cardboard. Media: Glass fibre. EN 779:2002 efficiency: G2, G3. Gravimetric efficiency: 75% - 85%. Eurovent 4/5 efficiency: EU2, EU3. Recommended final pressure drop: 250 Pa. Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. Air flow / Unit Media pressure drop volume 2 area m m 3 /hr/Pa m3 Reference Type Model Dimensions (WxHxD) mm Filter classification EN779:2002 GP12242NOM Camglass GP GP12242NOM 305x610x50 G3 0.19 1200/50 0.01 0.20 GP15152NOM Camglass GP GP15152NOM 381x381x50 G3 0.15 990/50 0.01 0.15 GP15202NOM Camglass GP GP15202NOM 381x508x50 G3 0.19 1315/50 0.01 0.20 GP16202NOM Camglass GP GP16202NOM 406x508x50 G3 0.21 1400/50 0.01 0.20 GP16252NOM Camglass GP GP16252NOM 406x635x50 G3 0.26 1750/50 0.02 0.25 GP18182NOM Camglass GP GP18182NOM 457x457x50 G3 0.21 1400/50 0.02 0.20 GP20202NOM Camglass GP GP20202NOM 508x508x50 G3 0.26 1750/50 0.02 0.25 GP20242NOM Camglass GP GP20242NOM 508x610x50 G3 0.31 1460/50 0.02 0.30 GP20252NOM Camglass GP GP20252NOM 508x635x50 G3 0.32 2100/50 0.02 0.35 GP24242NOM Camglass GP GP24242NOM 610x610x50 G3 0.37 2400/50 0.02 0.40 GP12241NOM Camglass GP GP12241NOM 305x610x25 G2 0.19 1200/45 0.01 0.20 GP15151NOM Camglass GP GP15151NOM 381x381x25 G2 0.15 990/45 0.01 0.15 GP15201NOM Camglass GP GP15201NOM 381x508x25 G2 0.19 1315/45 0.01 0.20 GP16201NOM Camglass GP GP16201NOM 406x508x25 G2 0.21 1400/45 0.01 0.20 GP16251NOM Camglass GP GP16251NOM 406x635x25 G2 0.26 1750/45 0.01 0.25 GP18181NOM Camglass GP GP18181NOM 457x457x25 G2 0.21 1400/45 0.01 0.20 GP20201NOM Camglass GP GP20201NOM 508x508x25 G2 0.26 1750/45 0.01 0.25 GP20241NOM Camglass GP GP20241NOM 508x610x25 G2 0.31 1460/45 0.01 0.30 GP20251NOM Camglass GP GP20251NOM 508x635x25 G2 0.32 2100/45 0.01 0.35 GP24241NOM Camglass GP GP24241NOM 610x610x25 G2 0.37 2400/45 0.01 0.40 Other sizes are available on request. All dimensions are nominal. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 20 Unit weight kg As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. TIFICAT ER E C standard and non standard sizes Camfil Farr Solutions Pre-Filtration, Class G3 to F5 Pad Filters Pad Holding Frame industrial applications DI DU ALLY CER TI F W D Reference Type Model Dimensions (WxHxD) mm Filter classification EN 779:2002 Air flow/pressure drop m³/hr/Pa Media area m 2 Unit weight kg Unit volume m3 AMZ24242 NOM PHF-2S 2" POLY 597x597x45 G3 / G4 3240/109 0,36 1,2 0,016 AMZ20242 NOM PHF-2S 2" POLY 495x597x45 G3 / G4 2700/109 0,30 1,0 0,013 AMZ12242 NOM PHF-2S 2" POLY 292x597x45 G3 / G4 1620/109 0,18 0,6 0,007 AMZ24241 NOM PHF-1S T15-350 597x597x25 G3 / G4 1924/25 0,36 1,0 0,007 AMZ20241 NOM PHF-1S T15-350 495x597x25 G3 / G4 1595/25 0,30 0,9 0,005 AMZ12241 NOM PHF-1S T15-350 292x597x25 G3 / G4 941/25 0,18 0,6 0,003 AMZ24242 NOM PHF-2G 2" GLASS 597x597x45 G3 3240/60 0,36 1,2 0,016 AMZ20242 NOM PHF-2G 2" GLASS 495x597x45 G3 2700/60 0,30 1,0 0,013 AMZ12242 NOM PHF-2G 2" GLASS 292x597x45 G3 1620/60 0,18 0,6 0,007 AMZ24241 NOM PHF-1G 1" GLASS 597x597x25 G2 3240/50 0,36 1,0 0,007 AMZ20241 NOM PHF-1G 1" GLASS 495x597x25 G2 2700/50 0,30 0,9 0,005 AMZ12241 NOM PHF-1G 1" GLASS 292x597x25 G2 1620/50 0,18 0,6 0,003 Other sizes available on request - Alternative constructions also available. Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. IE D IN VI Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 21 A i r F i l t e r Te c h n o l o g y C E TIFICAT ER EN 779:2002 Application: Pre filtration in air conditioning or industrial processing systems. Type: Coarse grade filter. Frame: Standard galvanised mild steel. Media: Synthetic / glass fibre. EN 779:2002 efficiency: G2, G3, G4. Arrestance efficiency: 65% - 90%. Eurovent 4/5 efficiency: EU2, EU3, EU4. Temperature: 80°C maximum in continuous service. Humidity: 100% RH. Optional: Alternative frame materials available on request. Bag and Compact Filters, Class F5 to F9 • Suitable for commercial and • Support mesh downstream H E PA / U L PA F i l t e r s , C l a s s H10 to U17 • Retaining wire for media pad • Replaceable filter media Carbon and Chemical Filters • Robust construction Pre-Filtration, Class G3 to F5 Advantages Pre-Filtration, Class G3 to F5 Metal Panels EcoFlo Advantages • Totally washable • High mechanical strength • Low pressure drop • Suitable for high air flow conditions EN 779:2002 DI Reference Type IE D IN VI DU ALLY CER TI F W D Application: Kitchen extract systems, Pre filtration within air conditioning systems. Type: Grease elimination or coarse dust removal. Frame: Galvanised Mild Steel. Media: Knitted or multilayer pad. EN 779:2002 efficiency: G2, G3. Arrestance efficiency: 65% - 80%. Eurovent 4/5 efficiency: EU2, EU3. Temperature: 100°C maximum in continuous service. Humidity: 100% RH. Accessories: Handles and drain holes. Optional: Alternate materials available on request e.g. Stainless Steel. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. Dimensions WxHxD (mm) Model Filter classification Air flow/pressure drop Media EN 779:2002 (m³/hr/Pa) area (m 2 ) Unit weight (kg) Unit volume (m 3 ) GFP12122NOM EcoFlo GFP12122NOM 292x292x45 G2 810/30 0,09 1,2 0,004 GFP12242NOM EcoFlo GFP12242NOM 292x596x45 G2 1620/30 0,18 2,3 0,005 GFP20202NOM EcoFlo GFP20202NOM 495x495x45 G2 2250/30 0,25 3,4 0,011 GFP20242NOM EcoFlo GFP20242NOM 495x596x45 G2 2700/30 0,30 4,0 0,013 GFP24242NOM EcoFlo GFP24242NOM 596x596x45 G2 3240/30 0,36 4,5 0,016 MMP12122NOM EcoFlo MMP12122NOM 292x292x45 G3 810/40 0,09 1,2 0,004 MMP12242NOM EcoFlo MMP12242NOM 292x596x45 G3 1620/40 0,18 2,3 0,005 MMP20202NOM EcoFlo MMP20202NOM 495x495x45 G3 2250/40 0,25 3,4 0,011 MMP20242NOM EcoFlo MMP20242NOM 495x596x45 G3 2700/40 0,30 4,0 0,013 MMP24242NOM EcoFlo MMP24242NOM 596x596x45 G3 3240/40 0,36 4,5 0,016 Other dimensions available on request - Alternative constructions also available. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 22 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. TIFICAT ER E C • Support mesh on both sides Camfil Farr Solutions Pre-Filtration, Class G3 to F5 Media Rolls Cam Glass Media F Pre-Filtration, Class G3 to F5 TI Dust Media Velocity/pressure drop m/ Unit holding g/ 2 s/Pa area m volume m3 m² Reference Type Model Dimensions (meters) Filter classification EN 779:2002 PR5071020 50 mm PR 50 0.710 x 20 G2 14.20 1.8 / 30 600 0.71 PR5071040 50 mm PR 50 0.710 x 40 G2 28.40 1.8 / 30 600 1.42 PR50120 50 mm PR 50 1.0 x 20 G2 20.00 1.8 / 30 600 1.00 PR50140 50 mm PR 50 1.0 x 40 G2 40.00 1.8 / 30 600 2.00 PR50150020 50 mm PR 50 1.5 x 20 G2 30.00 1.8 / 30 600 1.5 PR50150040 50 mm PR 50 1.5 x 40 G2 60.00 1.8 / 30 600 3.00 PR50182920 50 mm PR 50 1.829 x 20 G2 36.58 1.8 / 30 600 1.829 PR50220 50 mm PR 50 2.0 x 20 G2 40.00 1.8 / 30 600 2.00 PR50230 50 mm PR 50 2.0 x 30 G2 60.00 1.8 / 30 600 3.00 PR7571040 75 mm PR 75 0.710 x 40 G2 28.40 1.8 / 35 750 2.13 PR10076220 100 mm PR 100 0.762 x 20 G2 15.24 1.8 / 40 900 1.524 PR100120 100 mm PR 100 1.0 x 20 G2 20.00 1.8 / 40 900 2.00 PR100140 100 mm PR 100 1.0 x 40 G2 40.00 1.8 / 40 900 4.00 PR100152420 100 mm PR 100 1.524 x 20 G2 30.48 1.8 / 40 900 3.048 PR100152440 100 mm PR 100 1.524 x 40 G2 60.96 1.8 / 40 900 6.096 PR100182920 100 mm PR 100 1.829 x 20 G2 36.58 1.8 / 40 900 3.658 GR5061040 50 mm GR50 0.610x40 G3 24.4 1.8 / 35 700 1.25 Bag and Compact Filters, Class F5 to F9 ALLY CER Application: For use as a pre filter in air conditioning, and spraybooth extract systems. Media: Glass Fibre. EN 779:2002 efficiency: G2 / G3. Arrestance efficiency: 75% - 85%. Eurovent 4/5 efficiency: EU2 / EU3. Temperature: 120°C maximum in continuous service. Humidity: 100% RH. Other sizes and cut pads available on request. Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. DU • Economical Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 23 A i r F i l t e r Te c h n o l o g y DI IE D IN VI • Full depth particle collection resin bonded • Smooth airflow through booths H E PA / U L PA F i l t e r s , C l a s s H10 to U17 EN 779:2002 • Continous filament glass fibres, Carbon and Chemical Filters TIFICAT ER E C Advantages Pre-Filtration, Class G3 to F5 Media Rolls Synthetic Media Rolls Advantages • Smooth airflow through booths • Progressively built up thermal bonded polyester fibre Application: For use as a pre filter in air conditioning, and spraybooth ventilation. Flammability: (DIN 53438) self extinguishing. Media: Synthetic. EN 779:2002 efficiency: G2, G3, G4. Arrestance efficiency: 65% - 92%. Eurovent 4/5 efficiency: EU2, EU3, EU4. Temperature: 80°C - 100°C maximum in continuous service. Humidity: 100% RH. TIFICAT ER E C • Non toxic EN 779:2002 DI IE D IN VI DU ALLY CER TI F Velocity / Media area m 2 pressure drop m/s/Pa Unit volume m3 Reference Type Model Dimensions (metres) Filter classification EN779:2002 Dust holding g/ Pack qty m² T15150SI220 Roll T15-150 2.05 x 20 G2 41 1.5 / 15 0.53 410 1 T15150SI120 Roll T15-150 1.0 x 20 G2 20 1.5 / 15 0.26 410 1 PST290SI220 Roll PST 290 2.05 x 20 G4 41 1.10 / 41 0.82 350 1 PST290SI120 Roll PST 290 1.0 x 20 G4 20 1.10 / 41 0.40 350 1 PST290SI76020 Roll PST 290 0.76 x 20 G4 15 1.10 / 41 0.30 350 1 T15-350 2.05 x 20 G4 41 1.5 / 25 0.62 678 1 T15350SI220 Roll T15500SI220 Roll T15-500 2.05 x 20 G4 41 1.5 / 35 0.08 540 1 POLY220 Roll POLY 50 2.05 x 20 G3 41 1.5 / 45 2.05 550 1 POLYS210 Roll POLY SOFT 50 2.0 x 10 G3 20 1.5 / 52 1.00 673 1 POLYS220 Roll POLY SOFT 50 2.0 x 20 G3 40 1.5 / 52 2.00 673 1 HC80150 Roll HC - 80 1.0 x 50 G2 50 1.5 / 12 0.50 360 1 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 24 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Other sizes and cut pads available on request. Camfil Farr Solutions Pre-Filtration, Class G3 to F5 Fan Coil Filters Fan Coil Filter • Low pressure drop sizes • Economical • Light and robust TIFICAT ER E EN 779:2002 DI IE D IN VI DU ALLY CER TI F W D Type Model Dimensions (WxHxD) mm Filter classification EN 779:2002 CircaSyn (size mm) T15-150 pad CircaSyn as required G2 CircaFoam (size mm) 20PPI foam CircaFoam as required G2 H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Reference Carbon and Chemical Filters Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Alternative filter materials also available - Other dimensions available on request - Alternative constructions also available. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 25 A i r F i l t e r Te c h n o l o g y C Application: Prevention of dust and dirt build up on heating/cooling coils within ventilation systems. Type: Coarse dust removal. Frame: Metal with downstream support. Media: Synthetic. EN 779:2002 efficiency: G2. Arrestance efficiency: 65%. Eurovent 4/5 efficiency: EU2. Temperature: 70°C maximum in continuous service. Humidity: 100% RH. Bag and Compact Filters, Class F5 to F9 • Available in a wide variety of Pre-Filtration, Class G3 to F5 Advantages Pre-Filtration, Class G3 to F5 Primary Bag Filters Hi-Cap ® 30P, 40P, 50P • Rigid self supporting pockets • Welded pocket construction • Robust metal header frame • High mechanical strength Application: Comfort air conditioning applications, pre filter applications. Type: Multi pocket bag filter. Case: Galvanised steel. Media: Synthetic fibres. EN 779:2002 efficiency: G3, G4, F5. Eurovent 4/5 efficiency: EU3, EU4, EU5 Recommended final pressure drop: 250 Pa. Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. TIFICAT ER E C Advantages EN 779:2002 DU ALLY CER TI F W D flow / Filter Number Media Air pressure classification of area m3/hr/ EN 779:2002 pockets m2 drop Pa Unit volume m3 Unit weight kg Energy Rating 3400/35 0.05 2.2 F 2800/35 0.05 2.0 F 1.4 1700/35 0.03 1.4 F 3.6 3400/30 0.05 2.7 F 5 3.0 2800/30 0.05 2.5 F 3 1.8 1700/30 0.03 1.6 F G4 6 2.7 3400/40 0.05 2.2 F G4 5 2.3 2800/40 0.05 2.0 F 287x592x380 G4 3 1.4 1700/40 0.03 1.4 F 592x592x500 G4 6 3.6 3400/35 0.05 2.7 F 20/20/5/40P/25* 490x592x500 G4 5 3.0 2800/35 0.05 2.5 F 12/20/3/40P/25* 287x592x500 G4 3 1.8 1700/35 0.03 1.6 F Hi-Cap 50P 24/15/6/50P/25* 592x592x380 F5 6 2.7 3400/80 0.05 2.4 F Hi-Cap 50P 20/15/5/50P/25* 490x592x380 F5 5 2.3 2800/80 0.05 2.2 F 1215350P25* Hi-Cap 50P 12/15/3/50P/25* 287x592x380 F5 3 1.4 1700/80 0.03 1.6 F 2420650P25* Hi-Cap 50P 24/20/6/50P/25* 592x592x500 F5 6 3.6 3400/75 0.05 3.0 F 2020550P25* Hi-Cap 50P 20/20/5/50P/25* 490x592x500 F5 5 3.0 2800/75 0.05 2.8 F 1220350P25* Hi-Cap 50P 12/20/3/50P/25* 287x592x500 F5 3 1.8 1700/75 0.03 1.8 F Reference Type Model Dimensions (WxHxD) mm 2415630P25* Hi-Cap 30P 24/15/6/30P/25* 592x592x380 G3 6 2.7 2015530P25* Hi-Cap 30P 20/15/5/30P/25* 490x592x380 G3 5 2.3 1215330P25* Hi-Cap 30P 12/15/3/30P/25* 287x592x380 G3 3 2420630P25* Hi-Cap 30P 24/20/6/30P/25* 592x592x500 G3 6 2020530P25* Hi-Cap 30P 20/20/5/30P/25* 490x592x500 G3 1220330P25* Hi-Cap 30P 12/20/3/30P/25* 287x592x500 G3 2415640P25* Hi-Cap 40P 24/15/6/40P/25* 592x592x380 2015540P25* Hi-Cap 40P 20/15/5/40P/25* 490x592x380 1215340P25* Hi-Cap 40P 12/15/3/40P/25* 2420640P25* Hi-Cap 40P 24/20/6/40P/25* 2020540P25* Hi-Cap 40P 1220340P25* Hi-Cap 40P 2415650P25* 2015550P25* Other sizes are available on request - 25* denotes a 25 mm header frame, if a 20 mm header frame is required please specify 20*. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 26 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. DI IE D IN VI Summary Bag and Compact Filters, Class F5 to F9 Hi-Flo® A-Series Page 29 Page 30 Page 31 Page 32 Bag Filters Glass Fibre Page 33 Bag Filters Synthetic Media S-Flo W P Series Bag Filters Synthetic Media S-Flo W U Series Bag Filters Synthetic Media S-Flo W A Series Page 34 Page 35 Page 36 Compact Filter Opakfil Green High Efficiency Panel Ecopleat & Ecopleat MCTA Pleated Compact Filter Riga-Flo Pleated Compact Filter OpakAir Page 37 Page 38 Page 39 Page 40 H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Bag and Compact Filters, Class F5 to F9 Hi-Flo U-Series Carbon and Chemical Filters ® Bag Filters Glass Fibre Hi-Flo P, PL-Series Hi-Flo T-Series ® Bag Filters Glass Fibre Hi-Flo M-Series ® As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Bag Filters Glass Fibre Filter Frames and Housings ® Pleated Compact Filter Airopac® Page 41 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 27 A i r F i l t e r Te c h n o l o g y Bag Filters Glass Fibre Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Bag and Compact Filters, Class F5 to F9 Bag and Compact Filters, Class F5 to F9 Eurovent Certified Performance Air filter certification You can count on us! Camfil Farr, in conjunction with the main independent test laboratories in Europe, is committed to bringing you the highest levels of transparency with regard to the new test protocols for air filters. The European Committee for Standardisation has recently published a new standard on "Particulate air filters for general ventilation determination of filtration performance". One of the aims of this new standard is to detail the in-situ performance of an air filter. This new test protocol provides accurate data on the effectiveness of your air filters operating under real life conditions. Please always specify filters tested in accordance with EN 779:2002. Your Camfil representative is available to explain this standard in detail should you require it - you can count on us! Independent test results Our Eurovent certification covers bag filters, compact filters and panel filters in classes F5-F9, tested to EN 779:2002. The initial pressure drop must remain within the tolerance levels set out in EN 779:2002.* All filters that we officially market in brochures or on our website in these filter classes are covered by the certification. Each class contains a range of product groups: • Same filter media/material (such as fibreglass) Air filter performance • Same basic design (such as bag filters, compact filters etc) • • • Read more on Eurovent’s website: www.eurovent-certification.com The filters are tested at independent test laboratories - in Sweden, the Technical Research Institute of Sweden, SP, in Borås; in Finland, VTT in Espoo. These are the only laboratories in Europe that are accredited to ISO 17025. The test laboratories are not told which company’s products they are testing, but are only given a number that Eurovent assigns to each individual filter. Tolerance levels for initial pressure drop defined in EN 779:2002: +(10%+Mt) or +(10Pa+Mt), whichever is highest. Mt = 5Pa (tolerance level defined in EN 779:2002) E TIFICAT ER EN 779:2002 IN DI Eurovent’s certification of our fine-dust filters means that you can rest assured that we live up to the performance requirements and the data we print in our official documentation. Our fine-dust filters are tested by independent laboratories selected by Eurovent and that means security for you. Select Camfil air filters with Eurovent certification - its guaranteed! model, type, filter material, filter class as per EN 779:2002, • Nominal airflow and initial pressure drop at nominal airflow. VI DU ALLY CER Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 28 TI F As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. • standard Filters must be tested by independent laboratories SP in Sweden and VTT in Finland The test laboratories must be ISO 17025 certified We as manufacturers must be quality certified to ISO 9000 or a corresponding standard Each year, Eurovent selects, at random, four new filters from our range for inspection • Published data must be available, specifying the D • Published data must be correct • The products must comply with the EN 779:2002 • Same filter class: F5, F6, F7, F8, F9 IE The key elements of the programme are that: • Same or lower air speed/net filter area C At Camfil Farr we are going a step further to ensure the best possible performance for our customers. The European ventilation industry organisation Eurovent, in collaboration with several European air-filter manufacturers, has developed a certification programme to guarantee that our products live up to our promises. Advantages • Rubust construction • Comprehensive range of standard sizes • Save energy - optimised design • Certified performance TIFICAT ER E EN 779:2002 D IN W IE DI VI DU ALLY CER TI F D • Large surface area Application: Air conditioning applications. Type: Extended surface multi pocket bag filter. Case: Galvanised steel. Media: Glass Fibre. EN 779:2002 efficiency: F6 (55-65%), F7 (80-85%), F8/9 (90-95%). Eurovent 4/5 efficiency: EU6, EU7, EU8. Recommended final pressure drop: 450 Pa (suggested economical change point 250Pa). Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. Unit weight kg Unit volume m3 Energy Rating 9.2 3400/65 3.3 0.05 B 10 7.7 2800/64 3.0 0.05 B 6 4.6 1700/65 1.9 0.03 B F7 12 9.2 3400/85 2.9 0.05 A F7 10 7.7 2800/83 2.5 0.05 A F7 6 4.6 1700/85 1.7 0.03 A F8/9 12 9.2 3400/130 2.9 0.05 A F8/9 10 7.7 2800/128 2.6 0.05 A F8/9 6 4.6 1700/130 1.8 0.03 A Type Model Dimensions (WxHxD) 535025A1 Hi-Flo M6 592x592x635 F6 12 535002A1 Hi-Flo N6 490x592x635 F6 535026A1 Hi-Flo O6 287x592x635 F6 535025A2 Hi-Flo M7 592x592x635 535002A2 Hi-Flo N7 490x592x635 535026A2 Hi-Flo O7 287x592x635 535025A3 Hi-Flo M9 592x592x635 535002A3 Hi-Flo N9 490x592x635 535026A3 Hi-Flo O9 287x592x635 Carbon and Chemical Filters Air flow/pressure drop m 3 /hr/Pa Filter of Media classification EN Number pockets area m 2 779:2002 Reference Other sizes are available on request - *Supplied with a 25mm header frame as standard, 20mm header available on request. Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. EFFICIENCY GUARANTEE Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 29 A i r F i l t e r Te c h n o l o g y C (LCC) • Controlled media spacing (CMS) Bag and Compact Filters, Class F5 to F9 Hi-Flo ® M-Series H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Bag Filters Glass Fibre Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Bag and Compact Filters, Class F5 to F9 Bag and Compact Filters, Class F5 to F9 Bag Filters Glass Fibre Hi-Flo ® P, PL-Series Advantages • Large surface area • Comprehensive range of standard sizes • Rubust construction • Low pressure drop • Controlled media spacing TIFICAT ER E C (CMS) EN 779:2002 DI IE D IN VI DU ALLY CER TI W F D • Certified performance Application: Air conditioning applications. Type: Extended surface multi pocket bag filter. Case: Galvanised steel. Media: Glass Fibre. EN 779:2002 efficiency: F6 (55-65%), F7 (80-85%), F8/9 (90-95%). Eurovent 4/5 efficiency: EU6, EU7, EU8. Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa). Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. Air flow/pressure drop m 3 /hr/Pa Unit weight kg Unit volume m3 Energy Rating 6.5 3400/70 2.9 0.05 B 8 5.2 2700/70 2.4 0.05 B 5 3.2 2100/95 1.6 0.03 B F7 10 6.5 3400/105 2.6 0.05 B F7 8 5.2 2700/105 2.4 0.05 B F7 5 3.2 1700/105 1.6 0.03 B F8 10 6.5 3400/150 2.4 0.05 B 490x592x534 F8 8 5.2 2700/150 2.4 0.05 B 287x592x534 F8 5 3.2 1700/150 1.6 0.03 B PL6 592x892x534 F6 10 9.7 5100/70 4.4 0.10 B QL6 490x892x534 F6 8 7.8 4200/70 4.0 0.11 B RL6 287x892x534 F6 5 4.8 2550/70 2.6 0.05 B PL7 592x892x534 F7 10 9.7 5100/110 3.8 0.11 B Hi-Flo QL7 490x892x534 F7 8 7.8 4200/110 3.6 0.11 B Hi-Flo RL7 287x892x534 F7 5 4.8 2550/110 2.2 0.05 B Hi-Flo PL9 592x892x534 F8/9 10 9.7 5100/153 4.1 0.11 B Hi-Flo QL9 490x892x534 F8/9 8 7.8 4200/154 3.7 0.11 B Hi-Flo RL9 287x892x534 F8/9 5 4.8 2550/151 2.5 0.05 B Filter of Media classification EN Number pockets area m 2 779:2002 Reference Type Model Dimensions (WxHxD) 535027A1 Hi-Flo P6 592x592x534 F6 10 535005A1 Hi-Flo Q6 490x592x534 F6 535028A1 Hi-Flo R6 287x592x534 F6 535027A2 Hi-Flo P7 592x592x534 535005A2 Hi-Flo Q7 490x592x534 535028A2 Hi-Flo R7 287x592x534 535027A3 Hi-Flo P9 592x592x534 535005A3 Hi-Flo Q9 535028A3 Hi-Flo R9 536004A1 Hi-Flo 536005A1 Hi-Flo 536006A1 Hi-Flo 536004A2 Hi-Flo 536005A2 536006A2 536004A3 536005A3 536006A3 Other sizes are available on request - *Supplied with a 25mm header as standard. 20mm header available on request. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 30 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. EFFICIENCY GUARANTEE Advantages • Controlled media spacing (CMS) • Comprehensive range of • High dust holding capacity TIFICAT ER E C standard sizes • Rubust construction EN 779:2002 DI IE D IN VI DU ALLY CER TI F W D • Certified performance Application: Comfort air conditioning applications, pre filter applications. Type: Multi pocket bag filter. Case: Galvanised steel. Media: Glass Fibre. EN 779:2002 efficiency: F5 (40-50%), F6 (55-65%), F7 (80-85%), F8 (90-95%). Eurovent 4/5 efficiency: EU5, EU6, EU7, EU8. Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa). Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. Reference Type Model Dimensions (WxHxD) Filter classification EN 779:2002 Number of pockets Media area m 2 Air flow/pressure drop m 3 /hr/Pa *35606060U Hi-Flo *3U-4050/6060/60 592x592x600 F5 8 6.0 3400/50 2.8 0.05 C *35606038U Hi-Flo *3U-4050/6060/38 592x592x380 F5 8 3.8 2700/75 2.3 0.05 C *35506060U Hi-Flo *3U-4050/5060/60 490x592x600 F5 6 4.6 2800/55 2.4 0.05 C *35506038U Hi-Flo *3U-4050/5060/38 490x592x380 F5 6 2.9 2250/80 1.9 0.05 C *35306060U Hi-Flo *3U-4050/3060/60 287x592x600 F5 4 3.0 1700/50 1.6 0.03 C *35306038U Hi-Flo *3U-4050/3060/38 287x592x380 F5 4 1.9 1350/75 1.4 0.03 C *36606060U Hi-Flo *3U-65/6060/60 592x592x600 F6 8 6.0 3400/80 2.8 0.05 B *36606038U Hi-Flo *3U-65/6060/38 592x592x380 F6 8 3.8 2700/95 2.3 0.05 B *36506060U Hi-Flo *3U-65/5060/60 490x592x600 F6 6 4.6 2600/80 2.4 0.05 B *36506038U Hi-Flo *3U-65/5060/38 490x592x380 F6 6 2.9 2250/100 1.9 0.05 B *36306060U Hi-Flo *3U-65/3060/60 287x592x600 F6 4 3.0 1700/80 1.6 0.03 B *36306038U Hi-Flo *3U-65/3060/38 287x592x380 F6 4 1.9 1350/95 1.4 0.03 B *37606060U Hi-Flo *3U-85/6060/60 592x592x600 F7 8 6.0 3400/125 2.8 0.05 B *37606038U Hi-Flo *3U-85/6060/38 592x592x380 F7 8 3.8 2700/150 2.3 0.05 B *37506060U Hi-Flo *3U-85/5060/60 490x592x600 F7 6 4.6 2600/125 2.4 0.05 B *37506038U Hi-Flo *3U-85/5060/38 490x592x380 F7 6 2.9 2250/165 1.9 0.05 B *37306060U Hi-Flo *3U-85/3060/60 287x592x600 F7 4 3.0 1700/125 1.6 0.03 B *37306038U Hi-Flo *3U-85/3060/38 287x592x380 F7 4 1.9 1350/150 1.4 0.03 B *38606060U Hi-Flo *3U-95/6060/60 592x592x600 F8 8 6.0 3400/185 2.8 0.05 B *38606038U Hi-Flo *3U-95/6060/38 592x592x380 F8 8 3.8 2700/195 2.3 0.05 B *38506060U Hi-Flo *3U-95/5060/60 490x592x600 F8 6 4.6 2600/185 2.4 0.05 B *38506038U Hi-Flo *3U-95/5060/38 490x592x380 F8 6 2.9 2250/200 1.9 0.05 B *38306060U Hi-Flo *3U-95/3060/60 287x592x600 F8 4 3.0 1700/185 1.6 0.03 B *38306038U Hi-Flo *3U-95/3060/38 287x592x380 F8 4 1.9 1350/195 1.4 0.03 B Energy Rating Carbon and Chemical Filters Unit volume Unit weight kg m3 Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. EFFICIENCY GUARANTEE Other sizes are available on request - *3 denotes a 25mm header frame, if a 20mm header frame is required please specify *2. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 31 A i r F i l t e r Te c h n o l o g y • Large surface area Bag and Compact Filters, Class F5 to F9 Hi-Flo ® U-Series H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Bag Filters Glass Fibre Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Bag and Compact Filters, Class F5 to F9 Bag and Compact Filters, Class F5 to F9 Bag Filters Glass Fibre Hi-Flo ® A-Series Advantages • High dust holding capacity • Robust construction • Controlled media spacing • Comprehensive range of TIFICAT ER E C (CMS) EN 779:2002 DI IE D IN VI DU ALLY CER TI F W D standard sizes Application: Comfort air conditioning applications, pre filter applications. Type: Multi pocket bag filter. Case: Galvanised steel. Media: Glass Fibre. EN 779:2002 efficiency: F5 (40-50%), F6 (55-65%), F7 (80-85%), F8 (90-95%). Eurovent 4/5 efficiency: EU5, EU6, EU7, EU8. Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa). Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. EFFICIENCY GUARANTEE Unit volume Unit weight kg m3 Type Model Dimensions (WxHxD) Filter classification EN 779:2002 Number of pockets *35606060A Hi-Flo *3A-4050/6060/60 592x592x600 F5 6 4.7 3400/70 2.4 0.05 D *35606038A Hi-Flo *3A-4050/6060/38 592x592x380 F5 6 2.9 2700/70 2.0 0.05 D *35506060A Hi-Flo *3A-4050/5060/60 490x592x600 F5 5 3.9 2800/70 2.1 0.05 D *35506038A Hi-Flo *3A-4050/5060/38 490x592x380 F5 5 2.4 2250/75 1.8 0.05 D *35306060A Hi-Flo *3A-4050/3060/60 287x592x600 F5 3 2.3 1700/70 1.5 0.03 D *35306038A Hi-Flo *3A-4050/3060/38 287x592x380 F5 3 1.5 1350/70 1.3 0.03 D *36606060A Hi-Flo *3A-65/6060/60 592x592x600 F6 6 4.7 3400/70 2.4 0.05 B *36606038A Hi-Flo *3A-65/6060/38 592x592x380 F6 6 2.9 2700/95 2.0 0.05 B *36506060A Hi-Flo *3A-65/5060/60 490x592x600 F6 5 3.9 2800/75 2.1 0.05 B *36506038A Hi-Flo *3A-65/5060/38 490x592x380 F6 5 2.4 2250/100 1.8 0.05 B *36306060A Hi-Flo *3A-65/3060/60 287x592x600 F6 3 2.3 1700/70 1.5 0.03 B *36306038A Hi-Flo *3A-65/3060/38 287x592x380 F6 3 1.5 1350/95 1.3 0.03 B *37606060A Hi-Flo *3A-85/6060/60 592x592x600 F7 6 4.7 2700/105 2.4 0.05 C *37606038A Hi-Flo *3A-85/6060/38 592x592x380 F7 6 2.9 2150/135 2.0 0.05 C *37506060A Hi-Flo *3A-85/5060/60 490x592x600 F7 5 3.9 2250/100 2.1 0.05 C *37506038A Hi-Flo *3A-85/5060/38 490x592x380 F7 5 2.4 1800/130 1.8 0.05 C *37306060A Hi-Flo *3A-85/3060/60 287x592x600 F7 3 2.3 1350/115 1.5 0.03 C *37306038A Hi-Flo *3A-85/3060/38 287x592x380 F7 3 1.5 1100/145 1.3 0.03 C *38606060A Hi-Flo *3A-95/6060/60 592x592x600 F8 6 4.7 2700/175 2.4 0.05 C *38606038A Hi-Flo *3A-95/6060/38 592x592x380 F8 6 2.9 2150/220 2.0 0.05 C *38506060A Hi-Flo *3A-95/5060/60 490x592x600 F8 5 3.9 2250/180 2.1 0.05 C *38506038A Hi-Flo *3A-95/5060/38 490x592x380 F8 5 2.4 1800/225 1.8 0.05 C *38306060A Hi-Flo *3A-95/3060/60 287x592x600 F8 3 2.3 1350/170 1.5 0.03 C *38306038A Hi-Flo *3A-95/3060/38 287x592x380 F8 3 1.5 1100/215 1.3 0.03 C Other sizes are available on request - *3 denotes a 25mm header frame, if a 20mm header frame is required please specify *2. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 32 Energy Rating As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Media Air flow/pressure drop surface m 2 m 3 /hr/Pa Reference Advantages • Large surface area • Controlled media spacing (CMS) • Ultra compact • High dust holding capacity TIFICAT ER E EN 779:2002 DI IE D IN VI DU ALLY CER TI F W D Application: Air conditioning applications. Type: Compact multi-pocket bag filter. Case: Galvanised steel. Media: Glass Fibre. EN 779:2002 efficiency: F6 (55-65%), F7 (80-85%), F8/9 (90-95%). Eurovent 4/5 efficiency: EU6, EU7, EU8. Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa). Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. Air flow/pressure drop m 3 /hr/Pa 12 5.5 3400/90 2.3 0.05 F6 10 4.5 2800/90 2.2 0.05 F6 6 2.7 1700/90 1.4 0.03 592x592x380 F7 12 5.5 3400/130 2.3 0.05 490x592x380 F7 10 4.5 2800/130 2.1 0.05 F7 6 2.7 1700/130 1.4 0.03 F8/9 12 5.5 3400/205 2.3 0.05 F8/9 10 4.5 2800/205 2.0 0.05 F8/9 6 2.7 1700/205 1.4 0.03 Type Model Dimensions (WxHxD) Filter classification Number of EN 779:2002 pockets 535023A1 Hi-Flo *TM6 592x592x380 F6 535024A1 Hi-Flo TN6 490x592x380 535022A1 Hi-Flo TO6 287x592x380 535023A2 Hi-Flo TM7 535024A2 Hi-Flo TN7 535022A2 Hi-Flo TO7 287x592x380 535023A3 Hi-Flo TM9 592x592x380 535024A3 Hi-Flo TN9 490x592x380 535022A3 Hi-Flo TO9 287x592x380 Unit Unit weight kg volume m 3 Carbon and Chemical Filters Media area m 2 Reference Other sizes are available on request - *Supplied with a 25mm header frame as standard. 20mm header available on request. Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. EFFICIENCY GUARANTEE Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 33 A i r F i l t e r Te c h n o l o g y C • Low pressure drop Bag and Compact Filters, Class F5 to F9 Hi-Flo ® T-Series H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Bag Filters Glass Fibre Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Bag and Compact Filters, Class F5 to F9 Bag and Compact Filters, Class F5 to F9 Bag Filters Synthetic Media S-Flo W P Series EN 779:2002 DI IE D IN VI DU ALLY CER TI F W D • Extended surface multi-pocket • High efficiency filter • Comprehensive range of standard sizes • Unique pocket design • Large surface area • Controlled media spacing (CMS) Application: Air conditioning applications. Type: Extended surface multi pocket bag filter. Case: Galvanised steel. Media: Synthetic Fibres. EN 779:2002 efficiency: F6 (55-65%), F7 (80-85%), F8 (90-95%). Eurovent 4/5 efficiency: EU6, EU7, EU8. Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa). Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. Filter Air flow/ Unit Unit of Media weight classification EN pressure drop Number 2 pockets area m volume m3 779:2002 m³/hr/Pa kg Reference Type Model Dimensions (WxHxD) mm *36606053PW S-Flo-W *P6 592x592x534 F6 3400/45 10 6,5 2,7 0,05 D *36506053PW S-Flo-W *Q6 490x592x534 F6 2800/45 8 5,2 2,4 0,05 D *36306053PW S-Flo-W *R6 287x592x534 F6 1700/45 5 3,2 1,6 0,03 D *37606053PW S-Flo-W *P7 592x592x534 F7 3400/75 10 6,5 2,7 0,05 E *37506053PW S-Flo-W *Q7 490x592x534 F7 2800/75 8 5,2 2,4 0,05 E *37306053PW S-Flo-W *R7 287x592x534 F7 1700/75 5 3,2 1,6 0,03 E *38606053PW S-Flo-W *P8 592x592x534 F8 3400/95 10 6,5 2,7 0,05 E *38506053PW S-Flo-W *Q8 490x592x534 F8 2800/95 8 5,2 2,4 0,05 E *38306053PW S-Flo-W *R8 287x592x534 F8 1700/95 5 3,2 1,6 0,03 E Other sizes are available on request - *Supplied with a 25mm header frame, if a 20mm header frame is required please specify *2. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 34 Energy Rating As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. TIFICAT ER E C Advantages TIFICAT ER E C Advantages EN 779:2002 DI DU ALLY CER TI F W D • Unique pocket design • Comprehensive range of • Large surface area standard sizes • Robust metal header frame • Controlled media spacing (CMS) Application: Air conditioning applications. Type: Extended surface multi pocket bag filter. Case: Galvanised steel. Media: Synthetic Fibres. EN 779:2002 efficiency: F6 (55-65%), F7 (80-85%), F8 (90-95%). Eurovent 4/5 efficiency: EU6, EU7, EU8. Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa). Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. Media area m 2 Unit weight kg Unit volume m3 Energy Rating 3400/46 8 6 2,8 0,05 F F5 2550/33 8 3,8 2,3 0,05 F F5 2800/46 6 4,6 2,4 0,05 F 490x592x380 F5 2100/33 6 2,9 1,9 0,05 F *UH5 287x592x600 F5 1700/46 4 3 1,6 0,03 F S-Flo-W *UH5/38 287x592x380 F5 1275/33 4 1,9 1,4 0,03 F S-Flo-W *UF6 592x592x600 F6 3400/50 8 6 2,8 0,05 E *36606038UW S-Flo-W *UF6/38 592x592x380 F6 2550/37 8 3,8 2,3 0,05 E *36506060UW S-Flo-W *UG6 490x592x600 F6 2800/50 6 4,6 2,4 0,05 E *36506038UW S-Flo-W *UG6/38 490x592x380 F6 2100/37 6 2,9 1,9 0,05 E *36306060UW S-Flo-W *UH6 287x592x600 F6 1700/50 4 3 1,6 0,03 E *36306038UW S-Flo-W *UH6/38 287x592x380 F6 1275/37 4 1,9 1,4 0,03 E *37606060UW S-Flo-W *UF7 592x592x600 F7 3400/60 8 6 2,8 0,05 E *37606038UW S-Flo-W *UF7/38 592x592x380 F7 2550/61 8 3,8 2,3 0,05 E *37506060UW S-Flo-W *UG7 490x592x600 F7 2800/60 6 4,6 2,4 0,05 E *37506038UW S-Flo-W *UG7/38 490x592x380 F7 2100/61 6 2,9 1,9 0,05 E *37306060UW S-Flo-W *UH7 287x592x600 F7 1700/60 4 3 1,6 0,03 E *37306038UW S-Flo-W *UH7/38 287x592x380 F7 1275/61 4 1,9 1,4 0,03 E *38606060UW S-Flo-W *UF8 592x592x600 F8 3400/80 8 6 2,8 0,05 E *38606038UW S-Flo-W *UF8/38 592x592x380 F8 3400/140 8 3,8 2,3 0,05 E *38506060UW S-Flo-W *UG8 490x592x600 F8 2800/80 6 4,6 2,4 0,05 E *38506038UW S-Flo-W *UG8/38 490x592x380 F8 2800/140 6 2,9 1,9 0,05 E *38306060UW S-Flo-W *UH8 287x592x600 F8 1700/80 4 3 1,6 0,03 E *38306038UW S-Flo-W *UH8/38 287x592x380 F8 1700/140 4 1,9 1,4 0,03 E Model Dimensions (WxHxD) mm Filter classification Air flow/pressure drop EN 779:2002 m³/hr/Pa *35606060UW S-Flo-W *UF5 592x592x600 F5 *35606038UW S-Flo-W *UF5/38 592x592x380 *35506060UW S-Flo-W *UG5 490x592x600 *35506038UW S-Flo-W *UG5/38 *35306060UW S-Flo-W *35306038UW *36606060UW Filter Frames and Housings Type Carbon and Chemical Filters Number of pockets Reference Other sizes are available on request - *Supplied with a 25mm header frame, if a 20mm header frame is required please specify *2. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 35 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. IE D IN VI • Multi-pocket bag filter Bag and Compact Filters, Class F5 to F9 S-Flo W U Series H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Bag Filters Synthetic Media Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Bag and Compact Filters, Class F5 to F9 Bag and Compact Filters, Class F5 to F9 Bag Filters Synthetic Media S-Flo W A Series Advantages • Multi-pocket bag filter • Unique pocket design • Comprehensive range of • Available in a range of EN 779:2002 DI IE D IN VI DU ALLY CER TI F W D efficiencies Application: Comfort air conditioning applications, pre filter applications. Type: Multi pocket bag filter. Case: Galvanised steel. Media: Synthetic Fibres. EN 779:2002 efficiency: F5 (40-50%), F6 (55-65%), F7 (80-85%), F8 (90-95%). Eurovent 4/5 efficiency: EU5, EU6, EU7, EU8. Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa). Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. Unit weight kg Unit volume m3 4,70 2,40 0,050 2,90 2,00 0,050 5 3,90 2,00 0,050 5 2,40 1,80 0,050 1700/51 3 2,30 1,50 0,030 1275/36 3 1,50 1,30 0,030 F6 3400/55 6 4,70 2,40 0,050 F6 2550/40 6 2,90 2,00 0,050 490x592x600 F6 2800/55 5 3,90 2,00 0,050 490x592x380 F6 2100/40 5 2,40 1,80 0,050 *C6 287x592x600 F6 1700/55 3 2,30 1,50 0,030 *C6/38 287x592x380 F6 1275/40 3 1,50 1,30 0,030 *A7 592x592x600 F7 2550/52 6 4,70 2,40 0,050 *A7/38 592x592x380 F7 2550/80 6 2,90 2,00 0,050 *B7 490x592x600 F7 2100/52 5 3,90 2,00 0,050 *B7/38 490x592x380 F7 2100/80 5 2,40 1,80 0,050 *C78 287x592x600 F7 1275/52 3 2,30 1,50 0,030 *C7/38 287x592x380 F7 1275/80 3 1,50 1,30 0,030 *A8 592x592x600 F8 3400/100 6 4,70 2,40 0,050 *A8/38 592x592x380 F8 3400/195 6 2,90 2,00 0,050 *B8 490x592x600 F8 2800/100 5 3,90 2,00 0,050 *B8/38 490x592x380 F8 2800/195 5 2,40 1,80 0,050 *C8 287x592x600 F8 1700/100 3 2,30 1,50 0,030 *C8/38 287x592x380 F8 1700/195 3 1,50 1,30 0,030 Model Dimensions (WxHxD) mm Filter classification EN 779:2002 Air flow/pressure drop m³/hr/Pa S-Flo-W *A5 592x592x600 F5 3400/50 6 S-Flo-W *A5/38 592x592x380 F5 2250/36 6 S-Flo-W *B5 490x592x600 F5 2800/50 S-Flo-W *B5/38 490x592x380 F5 2100/36 S-Flo-W *C5 287x592x600 F5 S-Flo-W *C5/38 287x592x380 F5 S-Flo-W *A6 592x592x600 S-Flo-W *A6/38 592x592x380 S-Flo-W *B6 S-Flo-W *B6/38 S-Flo-W S-Flo-W S-Flo-W S-Flo-W S-Flo-W S-Flo-W S-Flo-W S-Flo-W S-Flo-W S-Flo-W S-Flo-W S-Flo-W S-Flo-W S-Flo-W Reference Type *35606060AW *35606038AW *35506060AW *35506038AW *35306060AW *35306038AW *36606060AW *36606038AW *36506060AW *36506038AW *36306060AW *36306038AW *37606060AW *37606038AW *37506060AW *37506038AW *37306060AW *37306038AW *38606060AW *38606038AW *38506060AW *38506038AW *38306060AW *38306038AW Number of Media pockets area m 2 Other sizes are available on request - *Supplied with a 25mm header frame, if a 20mm header frame is required please specificy *2. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 36 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. TIFICAT ER E C standard sizes • Robust metal header frame Advantages • Large surface area • Long operating life • Certified performance optimised for LCC TIFICAT ER E C • Light and robust EN 779:2002 DI IE D IN VI DU ALLY CER TI W F D Application: Air conditioning applications and preparatory filtration in clean rooms. Type: High efficiency, incinerable filter. Frame: 25mm thick flange, polypropylene and ABS. Media: Glass fibre paper. Separator: Hot-melt beads. Sealant: Polyurethane. EN 779:2002 efficiency: F6, F7, F8, F9. Opacimetric efficiency: 65, 85, 95, 98%. EUROVENT 4/5 efficiency: EU6, EU7, EU8, EU9. Recommended final pressure drop: 450 Pa (suggested economical change point 350 Pa). Temperature: 70°C maximum in continuous service. Mounting system: Front and side access housing and frames are available, Type 8, Type L and FC housings. Type Model Dimensions (WxHxD) mm Filter classification EN 779:2002 Media Air flow/pressure Unit area weight drop m 3 /h/Pa kg m2 Unit volume m3 Energy Rating 1511.11.50 OPAKFIL-G -65 3OPGHF-242412-60 592x592x290 F6 19.0 4250/100 5 0.11 B 1511.21.50 OPAKFIL-G -65 3OPGHF-242012-60 592x490x290 F6 15.0 3400/100 4 0.09 B 1511.51.50 OPAKFIL-G -65 3OPGHF-241212-60 592x287x290 F6 9.0 2125/100 3 0.05 B 1511.12.50 OPAKFIL-G -85 3OPGHF-242412-90 592x592x290 F7 19.0 4250/110 5 0.11 A 1511.22.50 OPAKFIL-G -85 3OPGHF-242012-90 592x490x290 F7 15.0 3400/110 4 0.09 A 1511.52.50 OPAKFIL-G -85 3OPGHF-241212-90 592x287x290 F7 9.0 2125/135 3 0.05 A 1511.13.50 OPAKFIL-G -95 3OPGHF-242412-95 592x592x290 F8 19.0 4250/130 5 0.11 A 1511.23.50 OPAKFIL-G -95 3OPGHF-242012-95 592x490x290 F8 15.0 3400/130 4 0.09 A 1511.53.50 OPAKFIL-G -95 3OPGHF-241212-95 592x287x290 F8 9.0 2125/150 3 0.05 A 1511.17.50 OPAKFIL-G-98 3OPGHF-242412-98 592x592x290 F9 19.0 4250/160 5 0.11 B 1511.24.50 OPAKFIL-G-98 3OPGHF-242012-98 592x490x290 F9 15.0 3400/160 4 0.09 B 1511.57.50 OPAKFIL-G-98 3OPGHF-241212-98 592x287x290 F9 9.0 2125/160 3 0.05 B Carbon and Chemical Filters Reference Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. EFFICIENCY GUARANTEE Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 37 A i r F i l t e r Te c h n o l o g y • Less frequent changes Bag and Compact Filters, Class F5 to F9 Opakfil Green H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Compact Filter Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Bag and Compact Filters, Class F5 to F9 Bag and Compact Filters, Class F5 to F9 High Efficiency Panel Ecopleat & Ecopleat MCTA TIFICAT ER E C Advantages EN 779:2002 D IN W IE DI VI DU ALLY CER TI F D • Large surface area • Ultra compact • Savings in operating costs • High dust holding capacity • 10 times more filtration surface • Less frequent changes Application: Air conditioning or industrial processing systems and for mini air conditioning systems, individual modules. Type: High efficiency compact filter. Frame: Galvanised steel. Media: Glass fibre paper. Separator: Hot-melt beads. EN 779:2002 efficiency: F6, F7. Opacimetric efficiency: 65, 85%. Eurovent 4/5 efficiency: EU6, EU7. Recommended final pressure drop: Ecopleat: 350 Pa - Ecopleat MCTA: 250 Pa. Temperature: 70°C maximum in continuous service. Air flow/pressure Filter Unit Media 3 classification EN 2 drop at 0.45 m/s m / weight area m 779:2002 kg h/Pa Unit volume m3 Energy Rating 2 0.01 D 3 0.02 D 1700/110 2 0.01 D 3400/110 3 0.02 D 4000/85 4 0.04 D 715/65 1.5 0.01 D 2.1 665/55 1.5 0.01 D 3.6 1100/45 2 0.01 D 4.8 1570/50 3 0.01 D 2.85 1500/175 2 0.01 B 5.89 3000/160 3 0.02 B 3.13 1700/175 2 0.01 B F7 6.25 3400/175 3 0.02 B F7 14.1 4000/120 4 0.04 B 352x225x48 F6 1.3 350/38 1 0.01 D 400x240x48 F6 1.6 340/25 1.2 0.01 D MCTA 470x240x48 F6 1.9 680/50 1.3 0.01 D MCTA 550x240x48 F6 2.2 680/42 1.4 0.01 D Reference Type Model Dimensions (WxHxD) 1020.07.00 ECOPLEAT Ecopleat F6 287x592x48 F6 2.85 1500/105 1020.08.00 ECOPLEAT Ecopleat F6 592x592x48 F6 5.89 3000/100 1020.05.00 ECOPLEAT Ecopleat F6 305x610x48 F6 3.13 1020.06.00 ECOPLEAT Ecopleat F6 610x610x48 F6 6.25 1020.16.00 ECOPLEAT Ecopleat F6 610x610x98 F6 14.1 1020.80.02 ECOPLEAT Ecopleat F6 560x190x48 F6 1.8 1020.80.03 ECOPLEAT Ecopleat F6 255x480x48 F6 1020.80.04 ECOPLEAT Ecopleat F6 255x830x48 F6 1020.80.05 ECOPLEAT Ecopleat F6 255x1130x48 F6 1021.07.00 ECOPLEAT Ecopleat F7 287x592x48 F7 1021.08.00 ECOPLEAT Ecopleat F7 592x592x48 F7 1021.05.00 ECOPLEAT Ecopleat F7 305x610x48 F7 1021.06.00 ECOPLEAT Ecopleat F7 610x610x48 1021.16.00 ECOPLEAT Ecopleat F7 610x610x98 1020.80.01 ECOPLEAT MCTA 1020.80.10 ECOPLEAT MCTA 1020.80.11 ECOPLEAT 1020.80.12 ECOPLEAT Other dimensions available - Other models available, contact us - Also available in incinerable version: Ecopleat Green. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 38 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. EFFICIENCY GUARANTEE Advantages • Range of standard sizes • High efficiency • Rigid design concept • Suitable for turbulent airflow TIFICAT ER E C Application: Air conditioning applications. Type: Rigid pleated filter. Case: Galvanised steel. Media: Glass fibre. EN 779:2002 efficiency: F5 (40-45%), F6 (55-65%), F7 (80-85%), F8 (90-95%). Eurovent 4/5 efficiency: EU5, EU6, EU7, EU8. Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa). Temperature: 70°C maximum in continuous service. Holding frames: Front and side access housings and frames are available. EN 779:2002 DI IE D IN VI DU ALLY CER TI F W D Reference Type Model Dimensions (WxHxD) mm Filter classification EN 779:2002 Media surface m2 060558-007 Riga Flo Riga Flo 10 594x594x292 F5 5.4 3420/65 7.70 060558-012 Riga Flo Riga Flo 10 492x594x292 F5 4.4 2790/65 5.77 0.11 060558-008 Riga Flo Riga Flo 10 289x594x292 F5 2.6 1710/65 4.55 0.06 078367-007 Riga Flo Riga Flo 10 594x594x152 F5 2.7 2070/55 3.42 0.06 078367-016 Riga Flo Riga Flo 10 492x594x152 F5 2.2 1710/55 2.57 0.06 078367-008 Riga Flo Riga Flo 10 289x594x152 F5 1.3 990/55 2.21 0.03 060558-001 Riga Flo Riga Flo 15 594x594x292 F6 5.4 3420/70 7.70 0.11 060558-009 Riga Flo Riga Flo 15 492x594x292 F6 4.4 2790/70 5.77 0.11 060558-004 Riga Flo Riga Flo 15 289x594x292 F6 2.6 1710/70 4.55 0.06 078367-001 Riga Flo Riga Flo 15 594x594x152 F6 2.7 2070/65 3.42 0.06 078367-013 Riga Flo Riga Flo 15 492x594x152 F6 2.2 1710/65 2.57 0.06 078367-004 Riga Flo Riga Flo 15 289x594x152 F6 1.3 990/65 2.21 0.03 060558-002 Riga Flo Riga Flo 100 594x594x292 F7 5.4 3420/90 7.70 0.11 060558-010 Riga Flo Riga Flo 100 492x594x292 F7 4.4 2790/90 5.77 0.11 060558-005 Riga Flo Riga Flo 100 289x594x292 F7 2.6 1710/90 4.55 0.06 078367-002 Riga Flo Riga Flo 100 594x594x152 F7 2.7 2070/90 3.42 0.06 078367-014 Riga Flo Riga Flo 100 492x594x152 F7 2.2 1710/90 2.57 0.06 078367-005 Riga Flo Riga Flo 100 289x594x152 F7 1.3 990/90 2.21 0.03 060558-003 Riga Flo Riga Flo 200 594x594x292 F8 5.4 3420/130 7.70 0.11 060558-011 Riga Flo Riga Flo 200 492x594x292 F8 4.4 2790/130 5.77 0.11 060558-006 Riga Flo Riga Flo 200 289x594x292 F8 2.6 1710/130 4.55 0.06 078367-003 Riga Flo Riga Flo 200 594x594x152 F8 2.7 2070/175 3.42 0.06 078367-015 Riga Flo Riga Flo 200 492x594x152 F8 2.2 1710/175 2.57 0.06 078367-006 Riga Flo Riga Flo 200 289x594x152 F8 1.3 990/175 2.21 0.03 Air flow/presure drop at m 3 / Unit weight kg Unit volume m 3 h/Pa Filter Frames and Housings Carbon and Chemical Filters 0.11 Other sizes are available on request - PH version also available (with header frame) Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 39 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. EFFICIENCY GUARANTEE Bag and Compact Filters, Class F5 to F9 Riga-Flo H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Pleated Compact Filter Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Bag and Compact Filters, Class F5 to F9 Bag and Compact Filters, Class F5 to F9 Pleated Compact Filter OpakAir TIFICAT ER E C Advantages EN 779:2002 DI IE D IN VI DU ALLY CER TI F W D • Large surface area • Less frequent changes • Up to 6000 m 3 /hr air flow • Low pressure drop Application: High air flow air conditioning and process air applications. Type: High capacity compact filter. Case: Galvanised steel. Gasket: Half round EDPM. Media: Glass fibre paper. Separator: Hot-melt beads. Sealant: Polyurethane. EN 779:2002 efficiency: F8. Opacimetric efficiency: 95%. Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa). Temperature: 70°C maximum in continuous service. Mounting System: Front and side access housings and safechange systems are available. EFFICIENCY GUARANTEE 1514.13.05 OPAKAIR -95 OPR-E-F8 610x610x292 F8 4500/110 19,0 18,00 0,11 1514.53.05 OPAKAIR -95 OPR-E-F8 305x610x292 F8 2250/110 10,0 9,00 0,06 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 40 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Unit Unit weight kg volume m 3 Dimensions (WxHxD) mm Type Filter classification Air flow/pressure drop EN 779:2002 m³/hr/Pa Media area m 2 Model Reference Advantages • Low pressure drop • Large surface area • Robust metal header frame • Rigid design concept • High dust holding capacity W D Application: Air conditioning applications and preparatory filtration in clean rooms. Type: High efficiency compact filter, HF model with header frame. Case: Galvanised steel. Media: Glass fibre paper. Separator: Hot-melt beads. Sealant: Polyurethane. EN 779:2002 efficiency: F7. Opacimetric efficiency: 85%. Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa). Temperature: 70°C maximum in continuous service. Mounting system: Front and side access housing and frames are available, type 8, type L and FC housings. Media area Unit Unit weight kg volume m 3 m2 Reference Type Model Dimensions (WxHxD) mm Air flow/nominal pressure drop m³/h/Pa Energy Rating 304215 Airopac-90 3GGM-24246-90 610x610x150 3600/105 12,3 6,8 0,06 B 304219 Airopac-90 3GGM-12246-90 305x610x150 1800/110 6,1 4,0 0,03 B Airopac-HF-90 3GGMHF-24245-90 592x592x135 3600/135 10,3 6,8 0,05 B 301739 Airopac-HF-90 3GGMHF-12245-90 287x592x135 1800/160 4,5 3,8 0,02 B Filter Frames and Housings Carbon and Chemical Filters 301732 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 41 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. EFFICIENCY GUARANTEE Bag and Compact Filters, Class F5 to F9 Airopac ® H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Pleated Compact Filter Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Bag and Compact Filters, Class F5 to F9 Bag and Compact Filters, Class F5 to F9 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 42 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Notes Page 46 Page 47 Page 48 HEPA/ULPA Panels Megalam MD, MX, MG HEPA/ULPA Panels Megalam MX & MG - H14 HEPA/ULPA Panels Megalam MD - H10 & H14 HEPA/ULPA Panels Megalam MD & MG - U15 Page 49 Page 50 Page 51 Page 52 HEPA/ULPA Panels Megalam (Laminator) MDL & MXL - U15 & U16 HEPA/ULPA Panels Silent Hood Diffuser - H14 HEPA/ULPA Panels HEPA/ULPA Panels Megalam U (Gel) - H14 & U15 Megalam T (Gel) - H14 & U15 Page 55 Page 56 Filter Frames and Housings Page 53 Carbon and Chemical Filters Page 54 H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Page 45 HEPA/ULPA Panels Megalam MD & MX e-PTFE U15 Page 57 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 43 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Filters for High Efficiency Filters for High Efficiency Filters for High Efficiency Filters for High Efficiency Sofilair - H10 to H14 Sofilair Green Close Pleat - H13 Opakfil G Micretain - H10 Bag and Compact Filters, Class F5 to F9 Summary HEPA / ULPA Filters, Class H10 to U17 Pre-Filtration, Class G3 to F5 Camfil Farr Solutions H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7 HEPA / ULPA Filters, Class H 10 to U 1 7 European Standard EN 1822 EN1822 SOFILAIR and MEGALAM… what you can expect: 100% control of everything we produce. • Qualified personnel responsible for testing. • Unique serial number for each filter. • Clear, unambiguous control procedures specifying test conditions, target values and actual performance of our filters. • Complete traceability of materials and operations. • Equipment and systems certified by accredited bodies. • Tested performance verified by installation testing and validation. The CAMFIL extra: • Individual test results are recorded on a unique product label. The label has a detachable copy which can be used to record the position of the individual filters within your process. • It can also be used as part of the validation process ensuring regulatory compliance of your installation. In short EN 1822 means: • Individually certified filters • Tested using MPPS (Most Penetrating Particle Size) challenge. • Explicit, standardised test procedures. • Full traceability of materials and test data. • NB: the filter grades EU13 etc, are incompatible with EN 1822. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 44 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. All HEPA / ULPA filters produced by Camfil are supplied fully in accordance with the European Standard EN 1822 Advantages Type Application: Very high efficiency final filtration in air conditioning systems, housings and diffusers. Type: High air flow HEPA filter. Frame: Galvanised steel. Media: Glass fibre paper. Separator: Hot-melt beads. Sealant: Polyurethane. Gasket: One piece half round continuous gasket. EN 1822 efficiency: H10, H12, H13, and H14. MPPS efficiency: H10:>85%, H12:>99.5%, H13:>99.95%, H14:> 99.995%. Recommended final pressure drop: 600 Pa. Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency may occur. Temperature: 80°C maximum in continuous service. Mounting systems: Front and side access filter frames, FC Housings, terminal housings and safe change systems. Dimensions (WxHxD) mm Model with filter changes Filter classification Media EN 1822 area m 3 Air flow/preassure drop m 3 /h/Pa Unit Unit weight kg volume m 3 1575.02.00 Sofilair H10 SFR-E-2000-H10 305x610x292 H10 14 2000/230 8 0,06 1573.02.00 Sofilair H10 SFR-E-4000-H10 610x610x292 H10 21 4000/230 13 0,11 1570.01.00 Sofilair H10 SFR-E-5000-H10 610x610x292 H10 35 5000/230 16,5 0,11 1585.01.00 Sofilair H12 SFR-E-1500-H12 305x610x292 H12 16 1500/250 8,5 0,06 1580.01.00 Sofilair H12 SFR-E-3400-H12 610x610x292 H12 33 3400/250 16,5 0,11 1580.02.00 Sofilair H12 SFR-E-4000-H12 610x610x292 H12 40 4000/250 16,5 0,11 1568.01.00 Sofilair H13 SFR-E-1300-H13 289x595x292 H13 16 1300/250 8,5 0,06 1565.01.00 Sofilair H13 SFR-E-1500-H13 305x610x292 H13 16 1500/250 8,5 0,06 1567.01.00 Sofilair H13 SFR-E-3200-H13 595x595x292 H13 38 3200/250 15,5 0,11 1560.01.00 Sofilair H13 SFR-E-3400-H13 610x610x292 H13 33 3400/250 16,5 0,11 1560.02.00 Sofilair H13 SFR-E-4000-H13 610x610x292 H13 40 4000/250 16,5 0,11 1560.02.20 Sofilair H13 SFR-E-5000-H13 610x610x292 H13 40 5000/400 16,5 0,11 1565.01.02 Sofilair H14 SFR-E-1400-H14 610x305x292 H14 16 1400/280 1500/310* 8,5 0,06 1560.02.06 Sofilair H14 SFR-E-3500-H14 610x610x292 H14 40 3500/270 4000/310* 16,5 0,11 Carbon and Chemical Filters As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Reference D • Low pressure drop Filter Frames and Housings W • New ergonomic handle to assist m 3 /hr • Tested in accordance with EN 1822 *Maximum airflow Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 45 A i r F i l t e r Te c h n o l o g y EN1822 • High air flow rates, up to 5000 Bag and Compact Filters, Class F5 to F9 Sofilair - H10 to H14 H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Filters for High Efficiency Pre-Filtration, Class G3 to F5 Camfil Farr Solutions H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7 HEPA / ULPA Filters, Class H 10 to U 1 7 Filters for High Efficiency Sofilair Green Advantages • Totally incinerable • New ergonomic handle to assist with filter changes • High air flow rates • Corrosion resistant • Light weight construction W D Unit weight kg Unit volume m3 2000/230 6 0,06 5000/230 12 0,11 1500/250 10 0,06 4000/250 13,5 0,11 1500/250 6 0,06 4000/250 12 0,11 15 1400/280 1500/310* 6 0,06 38 3500/270 4000/310* 12 0,11 Model Dimensions (LxHxD) mm 1575.82.00 Sofilair Green H10 SFRG-P-2000-H10 305x610x292 H10 13 1570.81.00 Sofilair Green H10 SFRG-P-5000-H10 610x610x292 H10 33 1585.81.00 Sofilair Green H12 SFRG-P-1500-H12 305x610x292 H12 15 1580.82.00 Sofilair Green H12 SFRG-P-4000-H12 610x610x292 H12 38 1565.81.00 Sofilair Green H13 SFRG-P-1500-H13 305x610x292 H13 15 1560.82.00 Sofilair Green H13 SFRG-P-4000-H13 610x610x292 H13 38 1565.81.02 Sofilair Green H14 SFRG-P-1400-H14 305x610x292 H14 1560.82.06 Sofilair Green H14 SFRG-P-3500-H14 610x610x292 H14 Reference Type Filter Media area classification m2 EN 1822 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 46 Airflow/pressure drop m 3 /h/Pa As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. EN1822 Application: High efficiency final filtration in air conditioning systems, extraction from corrosive or hazardous environments. Type: High air flow incinerable HEPA filter. Frame: ABS. Media: Glass fibre paper. Separator: Hot-melt beads. Sealant: Polyurethane. Gasket: One piece half round continuous gasket. EN 1822 efficiency: H10, H12, H13, H14. MPPS efficiency: H10:>85%, H13:>99.95 & H14:>99.995%. Recommended final pressure drop: 600 Pa. Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency may occur. Temperature: 60°C maximum in continuous service. Mounting systems: Front and side access filter frames. Terminal housings and safe change systems. Camfil Farr Solutions H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7 Filters for High Efficiency Close Pleat - H13 Advantages Type Model Dimensions (WxHxD) mm Unit Filter classification Air flow/pressure drop Media area Unit EN 1822 m³/hr/Pa weight kg volume m 3 m2 229004A1 Steel case HEPA TREA-1000 610x610x292 H13 2700 / 250 229002A1 Steel case HEPA TREA-450 305x610x292 H13 1350 / 250 231007A1 Steel case HEPA MXEA-600 610x610x150 H13 1625 / 250 231004A1 Steel case HEPA MXEA-220 305x610x150 H13 820 / 250 226001A1 MDF case HEPA TRSA-1000 610x610x292 H13 2450 / 250 226003A1 MDF case HEPA TRSA-450 305x610x292 H13 1160 / 250 225006A1 MDF case HEPA MXSA-600 610x610x150 H13 1475 / 250 225007A1 MDF case HEPA MXSA-220 305x610x150 H13 690 / 250 23,5 13 0,13 11,7 7 0,07 13,4 12 0,07 6,7 6 0,04 21,4 13 0,13 10,1 7 0,07 12,1 12 0,07 5,7 6 Filter Frames and Housings Alternative models, sizes and constructions are available. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 47 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Reference D Bag and Compact Filters, Class F5 to F9 W Carbon and Chemical Filters EN1822 Application: Very high efficiency final filtration in air conditioning systems, housings, ducts and diffusers. Type: Close pleated very high efficiency filter. Frame: Galvanised steel / MDF. Gasket: Half round continuous expanded polyurethane. Media: Pleated glass paper. Separator: Hot melt beads. Sealant: Polyurethane. EN 1822 efficiency: H13. MPPS efficiency: ≥ 99.95%. DOP efficiency ≈ 0.3 μm: ≥ 99.99%. Recommended final pressure drop: 600 Pa. Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may occur. Temperature: 70°C maximum in continuous service. Mounting systems: FCB Housings, Ducts, Diffusers, CAMSAFE. Pre-Filtration, Class G3 to F5 • Very high efficiency • Compact design concept H E PA / U L PA F i l t e r s , C l a s s H10 to U17 • Range of standard sizes HEPA / ULPA Filters, Class H 10 to U 1 7 Filters for High Efficiency Opakfil G Micretain - H10 Advantages • Easy to install • Up to 4000 m 3 /hr air flow • Incinerable D Air flow / Filter Media pressure drop classification EN 2 area m 1822 m 3 /hr/Pa Unit weight kg Unit volume m3 1700/250 3 0.06 4000/250 6 0.11 9.0 1700/250 3 0.06 19.0 4000/250 6 0.11 Reference Type Model Dimensions (WxHxD) mm 1511.36.51 70PGHF-241212 Opakfil-G Micretain 592x287x290-01 H10 9.0 1511.35.51 70PGHF-242412 Opakfil-G Micretain 592x592x290-01 H10 19.0 1511.36.52 70PGHF-241212 Opakfil-G Micretain 592x287x290-10 H10 1511.35.52 70PGHF-242412 Opakfil-G Micretain 592x592x290-10 H10 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 48 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. W Application: Final filtration in air conditioning systems, industrial processes. Type: Very high efficiency, incinerable, compact filter. Frame: 25 mm thick flange, polypropylene and ABS. Gasket: Half round continuous expanded polyurethane. Position: 01- rear, 10- front. Media: Glass fibre paper. Separator: Hot-melt beads. Sealant: Polyurethane. EN 1822 efficiency: H10. MPPS efficiency: ≥ 85%. Recommended final pressure drop: 450 Pa. Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may occur. Temperature: 70°C maximum in continuous service. Holding Frames: Front and side access housings and frames are available. Type 8, Type L and FC housings. Megalam MD, MX, MG Advantages • Less pressure drop • Longer operating life • Quieter • Higher flow rate Example: Megalam H14 / 6P6 Filter area Maximum pressure drop W D MX MG 2 2 18m2 90 Pa (-25%) 70 Pa (-40%) 10m Pressure drop 0.45 m/s (600m3/h) EN1822 MD 120 Pa 3 900 m /h (190 Pa) Energy 3 600 m /h (90 Pa) 2000 m3/h (250 Pa) -25% -42% x 1.5 x 2.5 Less pressure loss More Flow Carbon and Chemical Filters Filter Frames and Housings Lower pressure drop Higher airflow rate More energy savings Longer operating life Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 49 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Lifespan 12.5m Bag and Compact Filters, Class F5 to F9 H E PA / U L PA P a n e l s Pre-Filtration, Class G3 to F5 Camfil Farr Solutions H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7 HEPA / ULPA Filters, Class H 10 to U 1 7 H E PA / U L PA P a n e l s Megalam MX & MG - H14 Advantages • Low pressure drop • Longer operating life • Quiet: LW = 35dB • Individually scanned in accordance with EN 1822 • Higher flow rate W D Med Filter classifica ia tion EN area 1822 m2 Air flow/ Unit pressure Unit volu weig drop max me ht kg m 3 /h/Pa m3 Type Model Dimensions (WxHxD) mm 3440.00.20 MEGALAM MXA 3P6 305x610x90 H14 6.3 300/90 650/195 3.0 0.02 3440.00.30 MEGALAM MXA 6P6 610x610x90 H14 12.7 600/90 1300/195 6.0 0.05 3440.00.40 MEGALAM MXA 9P6 915x610x90 H14 19.1 900/90 1950/195 9.0 0.05 3440.00.50 MEGALAM MXA 12P6 1220x610x90 H14 28.3 1200/90 2500/195 12.0 0.07 3444.00.20 MEGALAM MGA 3P6 305x610x110 H14 9.8 300/70 1000/220 5.0 0.02 3444.00.30 MEGALAM MGA 6P6 610x610x110 H14 19.8 600/70 2000/220 8.0 0.04 3444.00.40 MEGALAM MGA 9P6 915x610x110 H14 27.0 900/70 3000/220 10.0 0.06 3444.00.50 MEGALAM MGA 12P6 1220x610x110 H14 36.3 1200/70 4000/220 13.0 0.08 Other dimensions available on request - Also available with laminator Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 50 Air flow/ pressure drop m/s m 3 /h/Pa Reference As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. EN1822 Application: Final or return filtration for clean rooms with turbulent flow. Type: HEPA filtering panel with seal for mechanical clamping systems. Frame: Extruded and anodised aluminium. Gasket: Half round continuous expanded polyurethane. Media: Glass fibre paper. Separator: Hot-melt beads. Sealant: Polyurethane. Grid: Mild steel painted grille upstream and downstream. EN 1822 efficiency: H14. MPPS efficiency: ≥ 99.995%. Recommended final pressure drop: 600 Pa. Maximum flow rate: see table, use nominal values otherwise a reduction in efficiency may occur. Temperature: 70°C maximum in continuous service. Test: 100% individually scanned to EN 1822. Mounting system: Mechanical clamping structure, Terminal housing. Camfil Farr Solutions H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7 H E PA / U L PA P a n e l s Megalam MD - H10 & H14 Advantages Pre-Filtration, Class G3 to F5 • Guaranteed performance • Protection via 2 grids Reference Type Model Dimensions (WxHxD) mm Filter classification EN 1822 Media area m 2 Air flow / pressure drop at 0.45 m/s m 3 /h/Pa Unit weight kg Unit volume m3 3401.61.11 MEGALAM MDM 3P6 305x610x66 H10 4.6 300/70 2.0 0.02 3401.62.08 MEGALAM MDM 6P6 610x610x66 H10 9.3 600/70 4.0 0.03 3401.63.01 MEGALAM MDM 9P6 915x610x66 H10 14.0 900/70 6.0 0.05 3401.64.07 MEGALAM MDM 12P6 1220x610x66 H10 18.5 1200/70 9.0 0.07 3423.00.10 MEGALAM MDA 3P3 305x305x66 H14 2.4 150/140 1.0 0.01 3423.00.20 MEGALAM MDA 3P6 305x610x66 H14 4.8 300/130 3.0 0.02 3423.00.30 MEGALAM MDA 6P6 610x610x66 H14 10.0 600/120 5.0 0.03 3423.00.90 MEGALAM MDA 7P6 762x610x66 H14 12.3 750/120 5.0 0.04 3423.00.40 MEGALAM MDA 9P6 915x610x66 H14 14.8 900/120 6.0 0.05 3423.00.50 MEGALAM MDA 12P6 1220x610x66 H14 19.8 1200/120 9.0 0.07 3423.00.60 MEGALAM MDA 15P6 1525x610x66 H14 24.9 1500/120 10.0 0.07 3423.01.00 MEGALAM MDA 9P7 915x762x66 H14 18.6 1125/120 7.5 0.06 3423.01.10 MEGALAM MDA 12P7 1220x762x66 H14 24.9 1500/120 10.0 0.07 3423.01.20 MEGALAM MDA 15P7 1525x762x66 H14 31.0 1875/120 12.5 0.09 3423.01.30 MEGALAM MDA 18P7 1830x762x66 H14 37.2 2250/120 12.5 0.12 3423.01.40 MEGALAM MDA 3P9 305x915x66 H14 7.4 450/120 3.0 0.03 3423.01.50 MEGALAM MDA 9P9 915x915x66 H14 22.3 1350/120 9.0 0.06 3423.01.60 MEGALAM MDA 12P9 1220x915x66 H14 30.0 1800/120 12.0 0.08 Bag and Compact Filters, Class F5 to F9 H E PA / U L PA F i l t e r s , C l a s s H10 to U17 D Carbon and Chemical Filters As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. W Filter Frames and Housings EN1822 Application: Final or return filtration for clean rooms with turbulent flow. Type: HEPA filtering panel with seal for mechanical clamping mounting systems. Frame: Extruded and anodised aluminium. Gasket: Half round continuous expanded polyurethane. Media: Glass fibre paper. Separator: Hot-melt beads. Sealant: Polyurethane. Grid: Mild steel painted grille upstream and downstream. EN 1822 efficiency: H10 / H14. MPPS efficiency: H10: ≥ 85%, H14: ≥99.995%. DOP efficiency: H10: ≥ 95%, H14: ≥ 99.999%. Recommended final pressure drop: 600 Pa. Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may occur. Temperature: 70°C maximum in continuous service. Test: : 100% individually scanned to EN 1822. Mounting system: Mechanical clamping structure, Terminal housings. Other dimensions available on request Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 51 A i r F i l t e r Te c h n o l o g y • Low pressure drop HEPA / ULPA Filters, Class H 10 to U 1 7 H E PA / U L PA P a n e l s Megalam MD & MG - U15 Advantages • Guaranteed performance • Protection via 2 grids • 100% individual scanning test • Very high efficiency according to standard EN 1822 W D Filter classification Media EN 1822 area m 2 Air flow / pressure drop m 3 /hr/Pa Unit weight kg Unit volume m3 Reference Type Model Dimensions (WxHxD) mm 3445.00.30 MEGALAM MGGS 6P6 610x610x110 U15 3418.00.10 MEGALAM MDGS 3P3 305x305x66 U15 2,8 150/140 1.0 0,01 3418.00.20 MEGALAM MDGS 3P6 305x610x66 U15 5,5 300/140 2.0 0,02 3418.00.30 MEGALAM MDGS 6P6 610x610x66 U15 11,2 600/140 4.0 0,03 3418.00.90 MEGALAM MDGS 7P6 762x610x66 U15 14 750/140 5.0 0,04 3418.00.40 MEGALAM MDGS 9P6 915x610x66 U15 16,9 900/140 6.0 0,05 3418.00.50 MEGALAM MDGS 12P6 1220x610x66 U15 22,5 1200/140 8.0 0,07 3418.00.60 MEGALAM MDGS 15P6 1525x610x66 U15 28,3 1500/140 10.0 0,07 3418.00.80 MEGALAM MDGS 3P7 305x762x66 U15 7 375/140 2.5 0,02 3418.01.00 MEGALAM MDGS 9P7 915x762x66 U15 21,1 1125/140 7.5 0,06 3418.01.10 MEGALAM MDGS 12P7 1220x762x66 U15 28,3 1500/140 10.0 0,07 3418.01.20 MEGALAM MDGS 15P7 1525x762x66 U15 35,3 1875/140 12.5 0,09 3418.01.40 MEGALAM MDGS 3P9 305x915x66 U15 8,3 450/140 3.0 0,03 3418.01.50 MEGALAM MDGS 9P9 915x915x66 U15 25,3 1350/140 9.0 0,06 3418.01.60 MEGALAM MDGS 12P9 1220x915x66 U15 33,9 1800/140 12.0 0,08 8.0 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 52 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. EN1822 Application: Final or return filtration for clean rooms with turbulent flow. Type: ULPA filtering panel with seal for mechanical clamping systems. Frame: Extruded and anodised aluminium. Gasket: Half round continuous expanded polyurethane. Media: Glass fibre paper. Separator: Hot-melt beads. Sealant: Polyurethane. Grid: Mild steel painted grille upstream and downstream. EN 1822 efficiency: U15. MPPS efficiency: ≥ 99.9995%. Recommended final pressure drop: 600 Pa. Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may occur. Temperature: 70°C maximum in continuous service. Test: 100% individually scanned to EN 1822. Mounting system: Mechanical clamping structure, Terminal housings. Camfil Farr Solutions H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7 H E PA / U L PA P a n e l s Megalam (Laminator) MDL & MXL - U15 & U16 • Integrated laminator screen • 100% individual scanning test • ULPA U15 and U16 according to standard EN 1822 D Unit weight kg Unit volume m3 16.9 900/150 6.0 0.05 16.9 900/150 6.0 0.05 U15 22.5 1200/150 8.0 0.07 U15 22.5 1200/150 8.0 0.07 915x610x66 U16 18.4 900/165 6.0 0.05 915x610x66 U16 18.4 900/165 6.0 0.05 12P6-01 1220x610x66 U16 24.5 1200/165 8.0 0.07 12P6-01 1220x610x66 U16 24.5 1200/165 8.0 0.07 MEGALAM MXLGS 6P6-01 610x610x90 U15 15.4 600/120 5.6 0.05 MEGALAM MXLGS 6P6-10 610x610x90 U15 15.4 600/120 5.6 0.05 Type Model Dimensions (WxHxD) mm 3449.20.40 MEGALAM MDLGS 9P6-01 915x610x66 U15 3449.00.40 MEGALAM MDLGS 9P6-10 915x610x66 U15 3449.20.50 MEGALAM MDLGS 12P6-01 1220x610x66 3449.00.50 MEGALAM MDLGS 12P6-10 1220x610x66 3450.20.40 MEGALAM MDLSGS 9P6-01 3450.00.40 MEGALAM MDLSGS 9P6-10 3450.00.50 MEGALAM MDLSGS 3450.20.50 MEGALAM MDLSGS 3425.20.30 3425.00.30 Carbon and Chemical Filters Air flow/pressure drop m³/h/Pa Filter Media classification EN area m² 1822 Reference Filter Frames and Housings Other dimensions available on request Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 53 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. W Bag and Compact Filters, Class F5 to F9 EN1822 Application: Final filtration for clean rooms, clean devices and units with laminar flow. Type: ULPA filtering panel with laminator and gasket for mechanical clamping systems. Frame: Extruded and anodised aluminium. Gasket: Half round continuous expanded polyurethane. Media: Glass fibre paper. Separator: Hot-melt beads. Sealant: Polyurethane. Laminator: Screen bonded downstream for laminar diffusion. Grid: Mild steel painted grille placed upstream. EN 1822 efficiency: U15 / U16. MPPS efficiency: U15: ≥99.9995%, U16: ≥99.99995%. Recommended final pressure drop: 600 Pa. Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may occur. Temperature: 70°C maximum in continuous service. Test: 100% individually scanned to EN 1822. Mounting system: Mechanical clamping structure, Terminal housings. H E PA / U L PA F i l t e r s , C l a s s H10 to U17 • Laminarity better than +/- 20% Pre-Filtration, Class G3 to F5 Advantages HEPA / ULPA Filters, Class H 10 to U 1 7 H E PA / U L PA P a n e l s Silent Hood Diffuser - H14 Advantages • H14 compact filter-diffuser for • Quiet: LW = 35 dB clean room • Ready to install • Laminarity +/- 20% Application: Final filtration for clean rooms. Type: Ready to install HEPA/ULPA filter diffuser. Frame: Extruded and anodised aluminium, galvanised steel cover. Gasket: 10x5mm neoprene, self adhesive ready for installation. Media: Glass fibre paper. Separator: Hot melt beads. Sealant: Polyurethane. Connection: Spigot with outer dia. 315mm or 250mm depending on the model. Grid: Downstream in painted mild steel. EN 1822 efficiency: H14. MPPS efficiency: ≥99.995%. Recommended final pressure drop: 600 Pa. Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may occur. Temperature: 70°C maximum in continuous service. Test: 100% individually scanned in accordance with EN 1822. Mounting system: Mechanical clamping structures. Type Dimensions (WxHxD) Filter classification media mm EN 1822 area m 2 Model Air flow/nominal pressure drop m³/h/Pa Unit volume Unit weight kg m3 5970.00.21 Silent Hood MDSHA RF1 300x600x116/250 H14 4.2 300/140 10 0.03 5975.00.31 Silent Hood MDSHA RF1 600x600x116/315 H14 9.2 600/140 13 0.06 5975.00.41 Silent Hood MDSHA RF 905x600x116/335 H14 14 900/140 16 0.09 5975.00.51 Silent Hood MDSHA RF1 1210x600x116/315 H14 19 1200/140 19 0.13 5975.00.20 Silent Hood MDSHA RF1 305x610x116/250 H14 4.3 300/140 10 0.03 5975.00.30 Silent Hood MDSHA RF1 610x610x116/315 H14 9.4 600/140 13 0.06 5975.00.40 Silent Hood MDSHA RF 915x610x116/315 H14 14.6 900/140 16 0.09 5975.00.50 Silent Hood MDSHA RF 1220x610x116/315 H14 19.5 1200/140 19 0.13 Other dimensions available on request. Available in other grades and with a laminator Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 54 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Reference Camfil Farr Solutions H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7 H E PA / U L PA P a n e l s Megalam U (Gel) - H14 & U15 Advantages Pre-Filtration, Class G3 to F5 Reference Type Filter classification EN 1822 Dimensions (WxHxD)mm Media area m² Air flow/pressure drop m³/h/Pa Air flow / Unit pressure drop max m³/h/Pa volume m³ Unit weight kg 3413.08.96 MEGALAM MDA U H14 305x305x78 2.4 150/120 250/200 0.01 2.0 3413.08.89 MEGALAM MDA U H14 305x610x78 4.8 300/120 300/200 0.02 4.0 3413.08.79 MEGALAM MDA U H14 610x610x78 10.0 600/120 1000/200 0.03 6.0 3413.08.87 MEGALAM MDA U H14 915x610x78 14.8 900/120 1500/200 0.05 8.0 3413.08.90 MEGALAM MDA U H14 1220x610x78 19.8 1200/120 2000/200 0.06 11.0 3413.08.97 MEGALAM MDA U H14 305x762x78 6.1 375/120 625/200 0.02 4.5 3413.08.98 MEGALAM MDA U H14 915x762x78 18.6 1125/120 1875/200 0.05 9.0 3413.08.91 MEGALAM MDA U H14 1220x762x78 24.9 1500/120 2500/200 0.07 13.0 3413.08.88 MEGALAM MDA U H14 915x915x78 22.3 1350/120 2250/200 0.06 12.0 3413.08.95 MEGALAM MDA U H14 1220x915x78 29.0 1800/120 3000/200 0.08 15.0 3413.08.82 MEGALAM MDGS U U15 762x610x78 14.0 750/140 - 0.04 6.5 3413.08.81 MEGALAM MDGS U U15 915x610x78 16.9 900/140 - 0.05 8.0 3413.18.02 MEGALAM MDGS U U15 915x762x78 21.1 1125/140 - 0.05 9.0 3413.08.84 MEGALAM MDGS U U15 1220x762x78 28.3 1500/140 - 0.07 13.0 3413.08.80 MEGALAM MDGS U U15 915x915x78 25.3 1350/140 - 0.06 12.0 H E PA / U L PA F i l t e r s , C l a s s H10 to U17 D Filter Frames and Housings Other dimensions available on request. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 55 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. W Application: Final filtration for clean rooms and housings. Type: HEPA/ULPA filter with gel seal. Frame: Anodized aluminium. Gasket: PU gel. Media: Glass fibre paper. Separator: Hot melt beads. Sealant: Polyurethane. Grid: Mild steel white epoxy paint upstream and downstream. EN 1822 efficiency: H14 and U15. MPPS efficiency: H14 = 99.995%, U15 = 99.9995%. Temperature: 70°C maximum in continuous service. Test: 100% individually scanned in accordance with EN 1822. Carbon and Chemical Filters EN1822 • Can be assembled without clamping • 100% individual control Bag and Compact Filters, Class F5 to F9 • Leaktightness by means of gel HEPA / ULPA Filters, Class H 10 to U 1 7 H E PA / U L PA P a n e l s Megalam T (Gel) - H14 & U15 Advantages • Compact design • 100% individually scann tested in accordance with EN 1822 • Secure protection of the filter media W D Application: Gel seal filter for terminal housings and laminar flow environments. Type: HEPA/ULPA filter with gel seal. Frame: Extruded anodised aluminium. Media: Glass fibre paper. Separator: Hot-melt beads. Sealant: Polyurethane. Gasket: PU Gel. EN 1822 efficiency: H14 and U15. MPPS efficiency: H14 = 99.995%, U15 = 99.9995%. Recommended final pressure drop: 600 Pa. Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency may occur. Temperature: 70°C maximum in continuous service. Test: 100% individually scanned in accordance with EN 1822. Mounting systems: Ceiling mounted grid systems and terminal housings. Reference Type Model Dimensions (WxHxD) mm Filter classification EN 1822 Media area m2 Air flow/pressure drop m 3 /h/Pa Unit weight kg Unit volume m 3 3471.x0.10 MEGALAM MDT14 U-305x305x71-2G 305x305x71 H14 2,4 150/120 1 0,01 3471.x0.20 MEGALAM MDT14 U-305x610x71-2G 305x610x71 H14 4,8 300/120 2 0,02 3471.x0.30 MEGALAM MDT14 U-610x610x71-2G 610x610x71 H14 10 600/120 4 0,03 3471.x0.90 MEGALAM MDT14 U-762x610x71-2G 762X610X71 H14 12,3 750/120 5 0,04 3471.x0.40 MEGALAM MDT14 U-915x610x71-2G 915x610x71 H14 14,8 900/120 6 0,05 3471.x0.50 MEGALAM MDT14 U-1220x610x71-2G 1220x610x71 H14 19,8 1200/120 8 0,06 3471.x0.80 MEGALAM MDT14 U-305x762x71-2G 305x762x71 H14 6 375/120 2,5 0,02 3471.x1.00 MEGALAM MDT14 U-915x762x71-2G 915x762x71 H14 18,6 1125/120 7,5 0,06 3471.x1.10 MEGALAM MDT14 U-1220x762x71-2G 1220x762x71 H14 24,9 1500/120 10 0,07 3471.x1.50 MEGALAM MDT14 U-915x915x71-2G 915x915x71 H14 22,3 1350/120 9 0,06 3471.x1.60 MEGALAM MDT14 U-1220x915x71-2G 1220x915x71 H14 30 1800/120 12 0,08 3472.x0.20 MEGALAM MDT15 U-305x610x71-2G 305x610x71 U15 5,5 300/140 2 0,017 3472.x0.30 MEGALAM MDT15 U-610x610x71-2G 610x610x71 U15 11,2 600/140 4 0,034 3472.x0.90 MEGALAM MDT15 U-762x610x71-2G 762X610X71 U15 14 750/140 5 0,042 3472.x0.40 MEGALAM MDT15 U-915x610x71-2G 915x610x71 U15 16,9 900/140 6 0,051 3472.x0.50 MEGALAM MDT15 U-1220x610x71-2G 1220x610x71 U15 22,5 1200/140 8 0,068 3472.x0.80 MEGALAM MDT15 U-305x762x71-2G 305x762x71 U15 7 375/140 2,5 0,021 3472.x1.00 MEGALAM MDT15 U-915x762x71-2G 915x762x71 U15 21,1 1125/140 7,5 0,064 3472.x1.10 MEGALAM MDT15 U-1220x762x71-2G 1220x762x71 U15 28,3 1500/140 10 0,069 3472.x1.50 MEGALAM MDT15 U-915x915x71-2G 915x915x71 U15 25,3 1200/140 9 0,062 Please Note: Seal Position "01" : x = 2 Seal Position "10" : x = 3 Other dimensions available on request Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 56 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. EN1822 • Laminar air flow distribution Type D • No outgassing Application: Very high efficiency final filter for clean environments and LAF benches. Type: ULPA filter. Frame: Extruded anodised aluminium. Media: e PTFE (Teflon). Separator: Hot-melt beads. Sealant: Polyurethane. Gasket: Half round continuous expanded polyurethane. EN 1822 efficiency: U15 MPPS efficiency: > 99.9995% Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency may occur. Temperature: 70°C maximum in continuous service. Test: 100% individually scanned in accordance with EN 1822. Mounting system: Ceiling mounted grid systems, terminal housings and clean devices. Filter classification EN 1822 Dimensions (WxHxD)mm Media area m² Air flow/Preassure drop m³/h/Pa Unit Unit volume m³ weight kg 305x610x66 4,80 300/105 0,017 2,00 1645020Z MD15/PTFE-305×610 U15 1645050B MD15/PTFE-610×610 U15 610x610x66 9,70 605/100 0,034 4,00 1645150 MD15/PTFE-1220×610 U15 1220x610x66 19,50 1205/100 0,068 8,00 164550P1 MD15/PTFE-1220×915 U15 1220x915x66 29,20 1810/100 0,083 12,00 164902 MX15/PTFE-305×610 U15 305x610x90 6,60 300/85 0,023 2,80 164907 MX15/PTFE-610×610 U15 610x610x90 13,20 605/80 0,046 5,60 1649000 MX15/PTFE-1220×610 U15 1220x610x90 26,60 1205/80 0,092 11,20 16490000 MX15/PTFE-1220×915 U15 1220x915x90 40,10 1810/80 0,112 16,80 Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Reference W • Chemical resistance • High mechanical strength Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 57 A i r F i l t e r Te c h n o l o g y EN1822 • Very high efficiency Bag and Compact Filters, Class F5 to F9 Advantages H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Megalam MD & MX e-PTFE - U15 Carbon and Chemical Filters H E PA / U L PA P a n e l s Pre-Filtration, Class G3 to F5 Camfil Farr Solutions H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7 HEPA / ULPA Filters, Class H 10 to U 1 7 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 58 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Notes Camfil Farr Solutions Carbon and Chemical Filters Page 62 Page 63 Carbon Cylinders Camcarb Mounting Frames Bonded and Loose Filled Carbon Panels Camsure Compact Carbon Filter CitySorb Carbon Cylinders Camcarb Green Page 64 Page 65 Carbon and Chemical Filters Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Page 67 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 59 A i r F i l t e r Te c h n o l o g y Page 66 CityCarb ® Bag and Compact Filters, Class F5 to F9 Compact 2 in 1 solution H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Compact 2 in 1 solution CityFlo Pre-Filtration, Class G3 to F5 Summary Carbon and Chemical Filters Carbon and Chemical Filters I n d o o r a i r q u a l i t y, E N 1 3 7 7 9 pollution does not pass us by. It takes numerous different forms, for example vehicle exhaust gas, factory chimneys, the dust raised by car traffic and cigarette smoke. It has been known for some time that exposure to pollution has an impact on human beings. The common symptoms are headaches, watering eyes and lower performance at work. Such symptoms are traditionally referred to as Sick Building Syndrome or similar terms. The industrialised world The industrialised world has changed immeasurably over the past 50 years. One very real difference is that the air that we breathe is more heavily, and more diversely, polluted. Although there are natural sources of pollution, the main concern is pollution caused by human activity. Tens of thousands of synthetic chemicals (which do not exist in any natural state) are now manufactured at an estimated rate of more than a billion tons per year. These chemicals are released into the atmosphere when they are produced, and when they are used they can travel great distances. They inevitably form part of our lives. Our lifestyles (work and leisure) mean that we spend more and more time inside buildings. The fact that buildings have to be ventilated means that we are increasingly exposed to particulate and gas pollution from the outdoor air. The new European Standard for Ventilation The impact of pollution on our health Air pollution can be categorised as either particulate (dust) or gas (molecular). Particles enter the body and the respiratory system via breathing. Gas or molecular pollution also penetrates the body via the air we breathe, but from the lungs it enters the bloodstream and in turn infiltrates the whole body. Though these chemicals may be invisible, Recommendations in EN 13779 for air filters IAQ Indoor Air Quality Outdoor air quality IDA 1 (High) IDA 2 (Medium) IDA 3 (Moderate) IDA 4 (Low) ODA 1 F9 F8 F7 F6 ODA 2 F7 / F9 F6 / F8 F6 / F7 G4 / F6 ODA 3 F7 / F9 F8 F7 F6 ODA 4 F7 / F9 F6 / F8 F6 / F7 G4 / F6 ODA 5 F6 / GF / F9 F6 / GF / F9 F6 / F7 G4 / F6 Table refering to appendix "A3. Use of Air Filters" in The European Standard EN 13779. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 60 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. European Standard EN 13779 is aimed at achieving a comfortable, healthy indoor environment in all seasons with acceptable installation and running costs. EN 13779 has now been adopted as a national standard in all countries. It specifies the required filter performance in a system to achieve good IAQ taking into consideration contamination in the outdoor air. Outdoor air is split into five categories, from ODA 1, in which the air is pure apart from temporary pollution such as pollen, up to ODA 5 with high concentrations of gas and particles. This elevated pollution level ODA 5 is now typical of the contamination in urban areas. Key: 4. A very high level of adsorption, in the order of 20 - 40% by weight of dry carbon. 3. Good index with a capacity of 10 - 20%. 2. Mediocre index that may require a particularly long contact time, requires case by case study. 1. Practically no adsorption, another solution must be sought. 3 Pentylene 4 Medicinal odours 3 Pentyne 4 Acetic anhydride 3 Chlorine 4 Ethylene dichloride 4 Menthol 4 Perchloroethylene 3 Acetone 4 Chlorobenzene 3 Ethylene oxide 4 Mercaptan 4 Perfumes, cosmetics 1 Acetylene 4 Chloroform 2 Ethyl mercaptan 1 Methane 4 Perspiration 3 Acids 4 Chloronitropropane 4 Ethyl silicate 3 Methyl acetate 4 Petrol 3 Acrolein 4 Chloropicrin 4 Eucalyptol 4 Methyl acrylate 4 Phenol 4 Acrylic acid 4 Chloroprene 4 Faecal odours 3 Methyl alcohol 3 Phosgene 4 Acrylonitrile 3 Cigarette smells 3 Farmyard smells 3 Methyl bromide 4 Plastics 4 Adhesives 4 Cleaning solvents 4 Fertiliser 4 Methyl butyl ketone 2 Propane 4 Alcohol 3 Cooking smells 3 Film developing 3 Methyl chloride 4 Propanol 4 Amines 4 Creosote 2 Fish odours 4 Methylcyclohexane 2 Propylene 2 Ammonia 4 Cresol 4 Floral odours 4 Methylcyclohexanol 4 Propyl mercaptan 2 Amyl acetate 4 Cyclohexane 2 Formaldehyde 4 Méthylcyclohexanone 4 Resins 4 Amyl alcohol 4 Cyclohexanol 3 Formic acid 4 Methylene chloride 4 Rubber 4 Amyl ether 4 Cyclohexanone 3 Freon 3 Methyl ether 2 Slaughterhouse 3 Anaesthetics 4 Cyclohexene 4 Gangrene smell 4 Methyl ethyl ketone 3 Soap 4 Aniline 4 Deodorants 4 Garlic 4 Methyl isobutyl ketone 3 Solvents 4 Animal carcases 4 Detergents 4 Heptane 4 Methyl mercaptan 4 Styrene monomer 3 Animal odours 4 Dibromoethane 4 Heptylene 4 Monochlorobenzene 2 Sulphur components 4 Antiseptics 4 Dichlorobenzene 3 Hexane 4 Naphtha (coal tar) 2 Sulphur dioxide 4 Asphalt fumes 4 Dichloroethane 3 Hexylene 4 Naphtha (oil) 4 Sulphuric acid 3 Bathroom smells 4 Dichloroethylene 3 Hospital odours 4 Naphthalene 3 Sulphur trioxide 4 Benzene 4 Diesel fumes 4 Household smells 4 Nicotine 4 Tar 3 Bleaching solutions 3 Diethylamine 1 Hydrogen 3 Nitric acid 4 Tetrachloroethane 2 Body odours 3 Diethyl ketone 2 Hydrogen bromide 4 Nitrobenzene 4 Tetrachloroethylene 4 Bromine 4 Dimethylaniline 2 Hydrogen chloride 4 Nitroethane 3 Tetrahydrofuran 4 Burnt flesh 4 Dimethylsulfate 2 Hydrogen cyanide 2 Nitrogen dioxide 4 Tobacco odours 3 Butadiene 4 Dioxane 2 Hydrogen fluoride 4 Nitroglycerine 4 Toilet smells 2 Butane 4 Dipropyl ketone 3 Hydrogen iodide 4 Nitromethane 4 Toluene 4 Butanone 4 Disinfectants 2 Hydrogen sulphide 4 Nitropropane 4 Trichlorethylene 4 Butyl acetate 4 Embalming products 4 Incense 4 Nitrotoluene 4 Urea 4 Butyl alcohol 4 Essential oils 3 Industrial waste 4 Nonane 4 Uric acid 4 Butyl chloride 1 Ethane 4 Iodine 4 Octane 4 Vehicle exhaust 2 Butylene 3 Ether 4 Iodoform 4 Onions 4 Vinegar 4 Butyric acid 4 Ethyl acetate 3 Isoprene 4 Ozone 3 Vinyl chloride 4 Camphor 4 Ethyl acrylate 4 Isopropyl acetate 4 Paint odours 3 Wood alcohol 4 Caprylic acid 4 Ethyl alcohol 4 Isopropyl alcohol 4 Paradichlorobenzene 4 Xylene 3 Carbon disulphide 3 Ethylamine 4 Kerosene 3 Pentane 1 Carbon dioxide 4 Ethylbenzene 4 Lactic acid 4 Pentanone Bag and Compact Filters, Class F5 to F9 4 Lubricants 1 Ethylene H E PA / U L PA F i l t e r s , C l a s s H10 to U17 3 Ethyl bromide 4 Carbon tetrachloride Carbon and Chemical Filters 1 Carbon monoxide 4 Acetic acid Filter Frames and Housings 2 Acetaldehyde Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 61 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Adsorption index of Activated Carbon for various types of odour Camfil Farr Solutions Adsorption index of activated carbon Pre-Filtration, Class G3 to F5 Carbon and Chemical Filters Carbon and Chemical Filters Compact 2 in 1 solution CityFlo TIFICAT ER EN 779:2002 DI IE D IN VI DU ALLY CER TI F W • Double action: particle and • Ideal for filtering most low odour filtration • Range of standard sizes • Can be used to upgrade existing installations concentration interior and exterior pollutants • Robust metal header frame • Compact “2 in 1” solution Application: Particle and odour removal in Hospitals, Offices, Airports etc. Type: Multi pocket particle and gas filter. Frame: Galvanised steel. Media: Glass fibre and broad spectrum carbon. EN 779:2002 efficiency: F7 (80-85%). Temperature: 50°C maximum in continuous service. Humidity: 70% RH maximum. Holding frames: Front and side access holding frames are available: Type 8, Type L and FC Housings. E C Advantages D Reference Type Dimensions (WxHxD) mm Filter classification EN 779:2002 Number of pockets Carbon mass kg Air flow/pressure drop m³/hr/Pa 604001 CITYFLO 592x592x534 F7 10 2 3400/140 6 1,2 B 604002 CITYFLO 287x592x534 F7 5 1 1700/145 3,5 0,6 B 604003 CITYFLO 490x592x537 F7 8 1.5 2550/140 4.6 0.9 B Unit Unit weight kg volume m 3 Energy rating Two filters in one Well known bag filter construction is now available with a particle and gas filtration layer. The frame components are made of galvanized sheet metal to ensure a robust construction. City-Flo is the ultimate solution when a high performance bag filter and a high performance odour removal filter are needed in the same encapsulated space. The filter can be easily fitted into new or existing standard filter frames. High performance Camfil Farr glass fibre media is now combined with an exclusive broad spectrum carbon media that utilises the benefits of RAD (Rapid Adsorption Dynamics) to remove a wide range of VOCs and odours. High perfomance by using RAD The RAD characteristics ensure effective collection of gases within a bag filter design. The carbon also provides high efficiency removal of ozone, a major pollutant in city environments. Service life The filter can be replaced when pressure loss exceeds the maximum allowed value for the ventilation system or after a maximum of one year. Maintenance Following good practice for all filters, used City-Flo filters should be bagged immediately after removal from the unit and disposed of by the appropriate route. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 62 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Ultimate solution • Can be used to upgrade existing concentration interior and exterior pollutants • Range of standard sizes installations • Double action: particle and odour filtration Application: High efficiency particle filtration for deodorisation and purification of gas pollutants, used for filtration in offices, airports and industrial workshops. Type: High efficiency, activated carbon, incinerable filter. Frame: Polypropylene. Media: Synthetic fibre. EN 779:2002 efficiency: F7 with very fine grains of activated carbon. Maximum flow rate: 4000m3/h. Mounting system: "Camfil universal frame" frames in kit form, FC type housings. Reference Type Model Dimensions (WxHxD) mm Filter classification EN 779:2002 Carbon mass Air flow pressure drop Unit Type of for contact time = 0.1 weight carbon kg s m 3 /h/Pa Unit Volume m3 5716522 CITYCARB OPKCC-242412-85-0 592x592x290 F7 3 RAD 3400/120 7.5 0.11 5716532 CITYCARB OPKCC-242012-85-0 592x490x290 F7 2.5 RAD 2800/120 6.1 0.09 5716542 CITYCARB OPKCC-241212-85-0 592x287x290 F7 1.5 RAD 1700/120 3.8 0.05 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Citycarb has been specifically designed to easily improve the quality of indoor air due to its "2 in 1" concept: 1. Highly effective filtration: Classed as F7 according to EN 779:2002, it stops 85% of 1 micron particles and meets the recommendations of UNICLIMA and EUROVENT 12/1-92. 2. Adsorption of odours and pollution: This specifically designed product can provide efficiencies as high as 99% for Sulphur Dioxide, the main pollutant in urban environments. Citycarb is easy to use Citycarb is designed to fit in place of the existing pocket or compact filter within an air handling system. The existing frames can be used because the filter fixings are the same and as you are not adding an extra filter stage, the pressure drop remains low. Citycarb uses a special ingredient - RAD The RAD or Rapid Adsorption Dynamic ensures the optimum efficiency of CityCarb. Rather than the amount of carbon (the traditional measure), it is the capacity of this new form to rapidly trap gasses which ensures the advanced performance of CityCarb. The carbon is in the form of very small granules into which gas molecules can rapidly diffuse. Citycarb eliminates the harmful effects of urban pollution CityCarb is specifically designed to handle common substances found in atmospheric contamination: NOX is caused by traffic, power stations and industrial plants. Sulphur Dioxide is mainly produced by power station emissions however traffic pollution greatly adds to the problem. Ammonia is caused by agriculture and industrial processes. Hydrochloric acid is a by product from incineration plants. Volatile Organic Compounds (VOC’s) are casued by vehicle exhaust, solvents and aerosols. Butadiene 1.3 is caused by vehicle emissions. Some of these molecules are included in the calculation of the atmospheric pollution index. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 63 Bag and Compact Filters, Class F5 to F9 D • 100% incinerable • Ideal for filtering most low H E PA / U L PA F i l t e r s , C l a s s H10 to U17 W • Compact “2 in 1” solution Carbon and Chemical Filters Advantages Filter Frames and Housings CityCarb ® A i r F i l t e r Te c h n o l o g y Compact 2 in 1 solution Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Carbon and Chemical Filters Carbon and Chemical Filters Compact Carbon Filter CitySorb Advantages W D • Range of standard sizes • High efficiency • Rigid design concept • Large air flow capacity Application: Adsorption of odours and gasses in air conditioning applications. Type: Rigid pleated filter. Case: Polystyrene. Media: Multilayer carbon media. Sealant: Polyurethane. Separators: Hot-melt. Gasket: One piece PU gasket. Recommended temperature range: 0-40°C. Recommended relative humidity: < 70% RH. Holding frames: Front and side access housings and frames are available, Type 8, Type L and FC Housings. Reference Type Model Dimensions (WxHxD) mm Media area m 2 5718522 CITYSORB OPKCS-242412-01 PU 592x592x292 8.0 3400/80 10.8 0.02 5718532 CITYSORB OPKCS-242012-01 PU 592x490x292 6.6 2800/80 9.2 0.04 5718542 CITYSORB OPKCS-241212-01 PU 592x287x292 3.5 1500/80 5.4 0.02 Air flow / pressure drop Unit weight kg m 3 /hr/Pa Unit Volume m3 Citysorb is a high-efficiency compact molecular filter for addressing IAQ issues in public and commercial buildings. This filter satisfies demands to tackle nuisance odours and provide occupants with the highest indoor air quality as specified in the European Standard EN 13779. The material selection and construction method ensures that Citysorb is a clean, light filter that is both quick and easy to maintain. efficiency % Temperature 23º C Humidity 50% Concentration 80ppm Airflow 3400 m3/h Citysorb dP. 91 Pa adsorbed toluene Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 64 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Also available, Citysorb Acid, for more efficient treatment of specific acid molecules. Advantages • Completely incinerable • Conical inlet • Low pressure drop • Rapid bayonet fitting system • Reduced weight • Corrosion resistant • Two integral moulded TPE • High performance gaskets Application: Adsorption of odours, VOC’s and / or low toxicity gases for airports, museums, kitchens, hospitals or clean room industry. Type: Cylindrical activated carbon cartridge in ABS and HDPE. Temperature: 40°C maximum in continuous service. Mounting System: Camcarb mounting frame, FC-CC housings. Cylinders: ABS plastic. Carbon: "Broad Spectrum" activated carbon, adsorption of odours, ozone and organic gases, impregnated activated carbon, adsorption of non-organic gases. Media: Coconut shell carbon CM05. Reference Type Model Dimensions (WxHxD) mm Carbon thickness mm Carbon weight kg Carbon type * Airflow/ pressure drop m 3 /h/Pa Unit weight kg Unit volume m3 571750 Camcarb Green Cylinder 2600 147x93x450 26 2,3 CM 05 80/30 2,7 0,007 571760 Camcarb Green Cylinder3500 147x93x600 26 3,1 CM 05 100/30 3,7 Carbon and Chemical Filters Filter Frames and Housings Air flow and air distribution of CAMCARB Green Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 65 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. * Based on a contact time of 0.2 sec. Alternative models are also available. Bag and Compact Filters, Class F5 to F9 Camcarb Green H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Carbon Cylinders Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Carbon and Chemical Filters Carbon and Chemical Filters Carbon Cylinders Camcarb Mounting Frames Advantages • Modular design adaptable for • Rapid fitting system via all types of installations • Reduced weight • Quick and easy service bayonet fitting Application: Assembly of Camcarb activated carbon cylinders. Type: Quick bayonet-mounted support frame for Camcarb cylinders. Design: Galvanised steel or stainless steel. For filters: Camcarb activated carbon cylinders. Mounting: Bayonet locking. W Dimensions (WxHxD) mm Cylinder capacity Unit weight kg Unit volume m3 Frame G8 305x610x70 8 3.0 0.02 Camcarb Frame G16 610x610x70 16 4.8 0.04 Camcarb Frame G8 SS 305x610x70 8 4.0 0.02 Camcarb Frame G16 SS 610x610x70 16 5.0 0.04 Reference Type 1618.60.00 Camcarb 1618.62.00 1618.57.00 1618.59.00 Model Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 66 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. D Camsure Advantages W D • Range of standard and non • Clean, dust free construction standard sizes • High performance • Suitable for a wide range of air volumes Application: Adsorption of odours and gases in air conditioning applications. Type: Bonded and granular carbon panels. Case: Galvanised steel. Media: Wide spectrum carbon. Temperature: 40°C maximum in continuous service. Mounting systems: Front and side access housings and frames are available. Reference Type Nominal size (WxHxD) mm Air flow / pressure drop m 3 /h/Pa Unit weight kg Unit volume m 3 CPB60060030NOM Bonded Carbon Panel 600x600x30 324/160 6.0 0.012 CPB60030030NOM Bonded Carbon Panel 600x300x30 160/160 3.0 0.006 CPG60060030NOM Granular Carbon Panel 600x600x30 324/127 6.0 0.012 CPG60030030NOM Granular Carbon Panel 600x300x30 160/127 3.0 0.006 Bag and Compact Filters, Class F5 to F9 Bonded and Loose Filled Carbon Panels Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Carbon and Chemical Filters H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Air volume required to give a contact time of 0.1 second. Above are sample sizes, filters are available in a comprehensive range of sizes, please specify. Carbon and Chemical Filters Filter Frames and Housings Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 67 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Also available with stainless steel case. Housings, frames & special applications Filter Holding Frames Filter Holding Frames Absolute Filter Holding Frame Type 8 - Filter Holding Frame Filter Housing FCB-P Filter Housing FCBS-HF Page 70 Page 71 Page 72 Page 73 Filter Housing FCBS-A Filter Housing FCBL-CC Filter Housing FCBL-CS Filter Housing FCBL-HF Page 74 Page 75 Page 76 Page 77 Terminal Filter Housings Pharmaseal Filter Containment Systems Camsafe Filters for High Temperature Termikfil 2000 Filters for High Temperature Page 79 Page 80 Page 81 Page 78 Absolute® 1FRK Filters for Painting Booths Filters for Painting Booths Filters for Painting Booths Filters for Painting Booths Paint Extract Filters Panolair SSI - Micretain H10 CDM Media Airopac® HT-HF Page 82 Page 83 Page 84 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 68 Page 85 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Summary Housings, frames & special applications Page 86 Filters for Gas Turbines Campulse EF Filters for Gas Turbines Hi-Flo T Dust Collector Gold Series Page 87 Page 88 Page 89 ® Pre-Filtration, Class G3 to F5 Cam GT ® Bag and Compact Filters, Class F5 to F9 Filters for Gas Turbines Camfil Farr Solutions Housings, frames & special applications Dust Collector HemiPleat Cartridges Carbon and Chemical Filters Filter Frames and Housings Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 69 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Page 90 Housings, frames & special applications Filter Holding Frames Absolute Filter Holding Frame Advantages • Modular design adaptable for • Pre drilled for easy assembly all types of installations • Location dimples in frame ensure correct filter fitting • Filter holding clips can be easily replaced as required Application: Mounting very high efficiency filters in air conditioning units and systems. Type: Front access filter holding frame. Construction: Galvanised steel or stainless steel. Filter Types: Absolute and Micretain very high efficiency filters. Filter fixing: Using 4 corner mounted clamps. W D Reference Type Exterior dimensions (WxHxD) mm Filter dimension (WxHxD) mm Unit weight kg Unit volume m 3 5107.06.01 Galvanised steel 626x626x335 610x610x292 12.5 0.13 5107.24.01 Galvanised steel 626x321x335 610x305x292 10.0 0.07 5107.60.01 Galvanised steel 610x610x335 595x595x292 12.3 0.12 5107.50.01 Galvanised steel 610x305x335 595x290x292 9.9 0.06 5107.06.02 Stainless steel 626x626x335 610x610x292 12.5 0.13 5107.24.02 Stainless steel 626x321x335 610x305x292 10.0 0.07 5107.60.02 Stainless steel 610x610x335 595x595x292 12.3 0.12 5107.50.02 Stainless steel 610x305x335 595x290x292 9.9 0.06 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 70 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Other dimensions and arrangements available on request. Camfil Farr Solutions Housings, frames & special applications Filter Holding Frames Type 8 - Filter Holding Frame Advantages • Modular design adaptable for Pre-Filtration, Class G3 to F5 • Robust rigid construction all types of installations • Pre drilled for easy assembly • Location dimples in frame • Filter holding clips can be ensure correct filter fitting easily replaced as required Type Model Exterior dimensions (WxH) mm Unit weight kg Unit volume m 3 079473-801 Type 8 610x610 610x610x68 2,4 0,04 079473-007 Type 8 508x610 508x610x68 2,2 0,03 079473-002 Type 8 508x508 508x508x68 2,0 0,03 079473-004 Type 8 305x610 305x610x68 1,8 0,02 H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Reference Bag and Compact Filters, Class F5 to F9 Application: Mounting air filters in air conditioning systems. Type: Front access filter holding frame. Construction: Galvanised steel. Gasket: Expanded neoprene. Filter Types: S-Flo W, Hi-Flo, Hi-Cap Bag Filters, 1", 2" and 4" Panel Filters, Opakfil, Airopac, Rigaflo and Ecopleat. Filter fixing: Using 4 corner mounted clips, to suit the installed filter. Note: Remember to order the frame and the appropriate clips. Other materials available on request other dimensions and arrangements available on request. Type Model 050025-000 C-70 clip for 1" and 2" deep (25 & 50 mm) C-70 074437-000 C-86 clip for 3" deep (75 mm) C-86 059615-001 C-77 clip for 4" deep (100 mm) C-77 059920-006 C-78-5 clip for 5" deep (125 mm) C-78 Carbon and Chemical Filters Reference Filter Frames and Housings Order 4 clips per frame, other materials available on request, clips to suit alternative or combination filters, available on request. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 71 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Fixing Clips Housings, frames & special applications Filter Housing FCB-P Advantages • Easy to Install • Gasket to seal between door and filter housing • Modular construction • Easy servicing • No tools needed to change filters • Stable and secure design Housing: Galvanised steel. Filter: Panel filters 25mm (1"), 50mm (2") and 95mm (4") deep. Alternative: Possibility to switch the housings 180° (flexibility to acces from left or right side). Please note: Stainless steel version is also available. D Reference Type Model Exterior dimensions (WxHxD) mm Interior dimensions (WxH) mm Number of filters 592x592 mm Number of filters 287x592 mm Unit volume m3 Unit weight kg 604001020 FCB-P 0510 05 10 399×744×202 309×614 - 1 0.06 7.3 604001040 FCB-P 1005 10 05 704×439×202 614×309 - 1 0.07 7.3 604001050 FCB-P 1010 10 10 704×744×202 614×614 1 - 0.12 9.5 604001060 FCB-P 1015 10 15 704×1055×202 614×925 1 1 0.17 15 604001070 FCB-P 1020 10 20 704×1360×202 614×1230 2 - 0.21 17 604001080 FCB-P 1025 10 25 704×1670×202 614×1540 2 1 0.26 21.5 604001090 FCB-P 1030 10 30 704×1975×202 614×1845 3 - 0.31 25 604001100 FCB-P 1510 15 10 1013×744×202 923×614 1 1 0.18 13.5 604001110 FCB-P 1520 15 20 1013×1360×202 923×1230 2 2 0.31 23 604001120 FCB-P 1530 15 30 1013×1975×202 923×1845 3 3 0.44 32.5 604001130 FCB-P 2010 20 10 1318×744×202 1228×614 2 - 0.22 15 604001140 FCB-P 2015 20 15 1318×1055×202 1228×925 2 2 0.31 25 604001150 FCB-P 2020 20 20 1318×1360×202 1228×1228 4 - 0.4 26.5 604001160 FCB-P 2025 20 25 1318×1670×202 1228×1540 4 2 0.49 35 604001170 FCB-P 2030 20 30 1318×1975×202 1228×1845 6 - 0.58 37 604001180 FCB-P 2510 25 10 1677×744×500 1537×614 2 604001190 FCB-P 2520 25 20 1677×1360×500 1537×1230 4 604001200 FCB-P 2530 25 30 1677×1975×500 1537×1845 6 604001210 FCB-P 3010 30 10 1982×744×500 1842×614 604001220 FCB-P 3015 30 15 1982×1055×500 1842×925 604001230 FCB-P 3020 30 20 1982×1360×500 604001240 FCB-P 3025 30 25 604001250 FCB-P 3030 3030 0.28 19 2 0.51 32.5 3 0.74 46 3 - 0.33 21.5 3 3 0.46 32.5 1842×1230 6 - 0.6 36 1982×1670×500 1842×1540 6 3 0.73 47.5 1982×1975×500 1842×1842 9 - 0.87 50.5 Other dimensions and arrangements available on request Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 72 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. W Camfil Farr Solutions Housings, frames & special applications Filter Housing FCBS-HF Advantages • Gasket to seal between door and filter housing • Modular construction • Easy servicing • No tools needed to change filters • Stable and secure design Model Exterior dimensions (WxHxD) mm 613002020 FCBS-HF 0510 05 10 399×744×500 309×614 _ 1 0.15 18 613002040 FCBS-HF 1005 10 05 704×439×500 614×309 - 1 0.16 18 613002050 FCBS-HF 1010 10 10 704×744×500 614×614 1 - 0.27 24 613002060 FCBS-HF 1015 10 15 704×1055×500 614×925 1 1 0.38 38 613002070 FCBS-HF 1020 10 20 704×1360×500 614×1230 2 - 0.49 42 613002080 FCBS-HF 1025 10 25 704×1670×500 614×1540 2 1 0.6 54 613002090 FCBS-HF 1030 10 30 704×1975×500 614×1845 3 - 0.71 62 613002100 FCBS-HF 1510 15 10 1013×744×500 923×614 1 1 0.39 33 613002110 FCBS-HF 1520 15 20 1013×1360×500 923×1230 2 2 0.7 57 613002120 FCBS-HF 1530 15 30 1013×1975×500 923×1845 3 3 1.03 80 613002130 FCBS-HF 2010 2010 1318×744×500 1228×614 2 - 0.5 38 613002140 FCBS-HF 2015 20 15 1318×1055×500 1228×925 2 2 0.71 62 613002150 FCBS-HF 2020 20 20 1318×1360×500 1228×1228 4 - 0.92 65 613002160 FCBS-HF 2025 20 25 1318×1670×500 1228×1540 4 2 1.13 86 613002170 FCBS-HF 2030 20 30 1318×1975×500 1228×1845 6 - 1.33 92 613002180 FCBS-HF 2510 25 10 1677×744×500 1537×614 2 0.64 47 613002190 FCBS-HF 2520 25 20 1677×1360×500 1537×1230 4 2 1.17 81 613002200 FCBS-HF 2530 25 30 1677×1975×500 1537×1845 6 3 1.7 114 613002210 FCBS-HF 3010 30 10 1982×744×500 1842×614 3 - 0.76 54 613002220 FCBS-HF 3015 30 15 1982×1055×500 1842×925 3 3 1.07 81 613002230 FCBS-HF 3020 30 20 1982×1360×500 1842×1230 6 - 1.38 89 613002240 FCBS-HF 3025 30 25 1982×1670×500 1842×1540 6 3 1.7 118 613002250 FCBS-HF 3030 30 30 1982×1975×500 1842×1842 9 - 2 126 Filter Frames and Housings Type Carbon and Chemical Filters Number of Number of Interior dimensions filters Unit Unit 592x592 filters 287x592 volume (WxH) mm m³ weight kg mm mm Reference H E PA / U L PA F i l t e r s , C l a s s H10 to U17 D Other dimensions and arrangements available on request Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 73 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. W Bag and Compact Filters, Class F5 to F9 Housing: Galvanised steel. Filters: S-FLO-W, HI-CAP, Hi-FLO and OPAKFIL G. Alternative: Possibility to switch the housings 180º (flexibility to access from left or right side). Please note: Stainless steel version is also available. Pre-Filtration, Class G3 to F5 • Easy to Install Housings, frames & special applications Filter Housing FCBS-A Advantages • Easy to Install • Gasket to seal between door and filter housing • Modular construction • Easy servicing • No tools needed to change filters • Stable and secure design Housing: Galvanised steel. Filters: Absolute, AIROPAC, MICRETAIN and SOFILAIR. Alternative: Possibility to switch the housings 180º (flexibility to access from left or right side). Please note: Stainless steel version is also available. D Reference Type Model Exterior dimensions (WxHxD) mm Interior dimensions WxH mm Number of filters 592x592 mm Number of filters 287x592 mm Unit volume m³ Unit weight kg 605003520 FCBS-A 0510 05 10 399×744×500 309×614 - 1 0.15 20 605003540 FCBS-A 1005 10 05 704×439×500 614×309 - 1 0.16 20 605003550 FCBS-A 1010 10 10 704×744×500 614×614 1 - 0.27 26 605003560 FCBS-A 1015 10 15 704×1055×500 614×925 1 1 0.38 41 605003570 FCBS-A 1020 10 20 704×1360×500 614×1230 2 - 0.49 46 605003580 FCBS-A 1025 10 25 704×1670×500 614×1540 2 0,6 59 605003590 FCBS-A 1030 10 30 704×1975×500 614×1845 3 - 0.71 68 605003600 FCBS-A 1510 15 10 1013×744×500 923×614 1 0.39 37 605003610 FCBS-A 1520 15 20 1013×1360×500 923×1230 2 2 0,7 62 605003620 FCBS-A 1530 15 30 1013×1975×500 923×1845 3 3 1.03 88 605003630 FCBS-A 2010 20 10 1318×744×500 1228×614 2 - 0,5 42 605003640 FCBS-A 2015 20 15 1318×1055×500 1228×925 2 2 0.71 68 605003650 FCBS-A 2020 20 20 1318×1360×500 1228×1228 4 - 0.92 72 605003660 FCBS-A 2025 20 25 1318×1670×500 1228×1540 4 2 1.13 95 605003670 FCBS-A 2030 20 30 1318×1975×500 1228×1845 6 - 1.33 101 605003680 FCBS-A 2510 25 10 1677×744×500 1537×614 2 1 0.64 51 605003690 FCBS-A 2520 25 20 1677×1360×500 1537×1230 4 2 1.17 89 605003700 FCBS-A 2530 25 30 1677×1975×500 1537×1845 6 3 1.7 126 605003710 FCBS-A 3010 30 10 1982×744×500 1842×614 3 - 0.76 59 605003720 FCBS-A 3015 30 15 1982×1055×500 1842×925 3 3 1.07 89 605003730 FCBS-A 3020 30 20 1982×1360×500 1842×1230 6 - 1.38 98 605003740 FCBS-A 3025 30 25 1982×1670×500 1842×1540 6 3 1.7 130 605003750 FCBS-A 3030 30 30 1982×1975×500 1842×1842 9 - 2 138 Other dimensions and arrangements available on request Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 74 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. W FCBL-CC Advantages • Easy to Install • Easy servicing • No tools needed to change • Stable and secure design filters • Gasket to seal between door and filter housing • Modular construction Housing: Galvanised steel. Filters: Carbon cylinders 1000, 2000 or 2600. Carbon CM05: For odours and VOC’s. Carbon CM07: For gases as H2S, SO2, NH3. Alternative: Possibility to switch the housings 180º (flexibility to access from left or right side). Please note: Stainless steel version is also available Unit volume m³ Unit weight kg 309×610 8 0.23 25.5 614×309 8 0.24 25.5 704×744×750 614×614 16 0.4 33 704×1055×750 614×925 24 0.57 49.5 704×1360×750 614×1230 32 0.73 58.5 704×1670×750 614×1540 40 0.9 75 10 30 704×1975×750 614×1845 48 1.06 82.5 15 10 1013×744×750 923×614 24 0.58 45 Model 607002020 FCBL-CC 0510 05 10 399×744×750 607002040 FCBL-CC 1005 10 05 704×439×750 607002050 FCBL-CC 1010 10 10 607002060 FCBL-CC 1015 10 15 607002070 FCBL-CC 1020 10 20 607002080 FCBL-CC 1025 10 25 607002090 FCBL-CC 1030 607002100 FCBL-CC 1510 607002110 FCBL-CC 1520 15 20 1013×1360×750 923×1230 48 1.05 75 607002120 FCBL-CC 1530 15 30 1013×1975×750 923×1845 72 1.53 110 607002130 FCBL-CC 2010 20 10 1318×744×750 1228×614 32 0.75 53 607002140 FCBL-CC 2015 20 15 1318×1055×750 1228×925 48 1.06 80.5 607002150 FCBL-CC 2020 20 20 1318×1360×750 1228×1228 64 1.37 91.5 607002160 FCBL-CC 2025 20 25 1318×1670×750 1228×1540 80 1.68 118 607002170 FCBL-CC 2030 20 30 1318×1975×750 1228×1845 96 1.99 128.5 607002180 FCBL-CC 2510 25 10 1677×744×750 1537×614 40 0.95 65 607002190 FCBL-CC 2520 25 20 1677×1360×750 1537×1230 80 1.74 111 607002200 FCBL-CC 2530 25 30 1677×1975×750 1537×1845 120 2.53 157.5 607002210 FCBL-CC 3010 30 10 1982×744×750 1842×614 48 1.13 72.5 607002220 FCBL-CC 3015 30 15 1982×1055×750 1842×925 72 1.6 111 607002230 FCBL-CC 3020 30 20 1982×1360×750 1842×1230 96 2.06 124.5 607002240 FCBL-CC 3025 30 25 1982×1670×750 1842×1540 120 2.53 161.5 607002250 FCBL-CC 3030 30 30 1982×1975×750 1842×1842 144 2.99 175 Filter Frames and Housings Type Carbon and Chemical Filters Number of cylinders Exterior dimensions (WxHxD) Interior dimension (WxH) mm mm Reference H E PA / U L PA F i l t e r s , C l a s s H10 to U17 D Other dimensions and arrangements available on request Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 75 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. W Bag and Compact Filters, Class F5 to F9 Filter Housing Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Housings, frames & special applications Housings, frames & special applications Filter Housing FCBL-CS Advantages • Easy to Install • Gasket to seal between door • Modular construction • No tools needed to change filters and filter housing • Easy servicing • Stable and secure design Housing: Galvanised steel. Filter: Bonded and Granular Carbon Panels. Standard Carbon: For odours and VOC’s. Impregnated Carbon: For gases as H2S, SO2, NH3. Alternative: Possibility to switch the housings to 180º (flexibility to access from left or right side). Please note: Stainless steel version is also available. D Exterior dimensions (WxHxD) Interior dimensions (WxH) Number of Carbon Unit volume Unit weight mm mm panels kg m3 Reference Type Model 611002040 FCBL-CS 1005 10 05 704x439x750 614x309 3 0.24 25.0 611002050 FCBL-CS 1010 10 10 704x744x750 614x614 6 0.40 32.5 611002060 FCBL-CS 1015 10 15 704x1055x750 614x925 9 0.57 51.5 611002070 FCBL-CS 1020 10 20 704x1360x750 614x1230 12 0.73 57.5 611002080 FCBL-CS 1025 10 25 704x1670x750 614x1540 15 0.90 73.5 611002090 FCBL-CS 1030 10 30 704x1975x750 614x1845 18 1.06 85.0 611002130 FCBL-CS 2010 20 10 1318x744x750 1228x614 12 0.75 51.5 611002140 FCBL-CS 2015 20 15 1318x1055x750 1228x925 18 1.06 84.0 611002150 FCBL-CS 2020 20 20 1318x1360x750 1228x1228 24 1.37 89.0 611002160 FCBL-CS 2025 20 25 1318x1670x750 1228x1540 30 1.68 117.5 611002170 FCBL-CS 2030 20 30 1318x1975x750 1228x1845 36 1.99 126.0 611002210 FCBL-CS 3010 30 10 1982x744x750 1842x614 18 1.13 73.5 611002220 FCBL-CS 3015 30 15 1982x1055x750 1842x925 21 1.60 111.0 611002230 FCBL-CS 3020 30 20 1982x1360x750 1842x1230 36 2.06 121.5 611002240 FCBL-CS 3025 30 25 1982x1670x750 1842x1540 45 2.53 162.0 611002250 FCBL-CS 3030 30 30 1982x1975x750 1842x1845 54 2.99 172.0 Other dimensions and arrangements available on request Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 76 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. W Camfil Farr Solutions Housings, frames & special applications Filter Housing FCBL-HF Advantages • Gasket to seal between door and filter housing • Modular construction • Easy servicing • No tools needed to change filters • Stable and secure design D Model Exterior dimensions (WxHxD) mm 613003020 FCBL-HF 0510 05 10 399x744x750 309x614 - 1 25 0.23 613003040 FCBL-HF 1005 10 05 704x439x750 614x309 - 1 25 0.24 613003050 FCBL-HF 1010 10 10 704x744x750 614x614 1 - 32.5 0.4 613003060 FCBL-HF 1015 10 15 704x1055x750 614x925 1 1 51.5 0.57 613003070 FCBL-HF 1020 10 20 704x1360x750 614x1230 2 - 57.5 0.73 613003080 FCBL-HF 1025 10 25 704x1670x750 614x1540 2 1 73.5 0.9 613003090 FCBL-HF 1030 10 30 704x1975x750 614x1845 3 - 85 1.06 613003100 FCBL-HF 1510 15 10 1013x744x750 923x614 1 1 45 0.58 613003110 FCBL-HF 1520 15 20 1013x1360x750 923x1230 2 2 77.5 1.05 613003120 FCBL-HF 1530 15 30 1013x1975x750 923x1845 3 3 110 1.53 613003130 FCBL-HF 2010 20 10 1318x744x750 1228x614 2 - 51.5 0.75 613003140 FCBL-HF 2015 20 15 1318x1055x750 1228x925 2 2 84 1.06 613003150 FCBL-HF 2020 20 20 1318x1360x750 1228x1228 4 - 89 1.37 613003160 FCBL-HF 2025 20 25 1318x1670x750 1228x1540 4 2 117.5 1.68 613003170 FCBL-HF 2030 20 30 1318x1975x750 1228x1845 6 - 126 1.99 613003180 FCBL-HF 2510 25 10 1677x744x750 1537x614 2 1 64 0.95 613003190 FCBL-HF 2520 25 20 1677x1360x750 1537x1230 4 2 110 1.74 613003200 FCBL-HF 2530 25 30 1677x1975x750 1537x1845 6 3 156 2.53 613003210 FCBL-HF 3010 30 10 1982x744x750 1842x614 3 - 73.5 1.13 613003220 FCBL-HF 3015 30 15 1982x1055x750 1842x925 3 3 111 1.6 613003230 FCBL-HF 3020 30 20 1982x1360x750 1842x1230 6 - 121.5 2.06 613003240 FCBL-HF 3025 30 25 1982x1670x750 1842x1540 6 3 162 2.53 613003250 FCBL-HF 3030 30 30 1982x1975x750 1842x1842 9 - 172 2.99 Filter Frames and Housings Type Carbon and Chemical Filters Interior Unit of filter Number of filter Unit dimensions (WxH) Number 592x592 mm 287x592 mm weight kg volume m3 mm Reference Other dimensions and arrangements available on request. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 77 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. W H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Bag and Compact Filters, Class F5 to F9 Housing: Galvinised steel. Filter: S-FLO-W, HI-FLO and HI-CAP. Alternative: Possibility to switch the housings 180° (flexibility to access from left or right side). Please note: Stainless steel version is also available. Pre-Filtration, Class G3 to F5 • Easy to Install Housings, frames & special applications Te r m i n a l F i l t e r H o u s i n g s Pharmaseal Advantages W D • Combines all the essential • Fully welded seams functions required for pharmaceutical and biotechnology facilities • Quick filter change • Controls and connections accessible from room side • Capability to isolate the room during filter change Application: Turbulent airflow clean rooms in pharmaceutical and bio-pharma. Type: Terminal filter ducted ceiling exhaust housing for HEPA/ULPA filters in clean rooms, gel seal, with individual bubble tight damper. Construction: 1.6mm aluminium, continuously welded. Duct connection: Round, fully welded ribbed inlet on top 305 diameter. Damper: Individual adjustable bubble tight damper for airflow adjustment and hood bubble tight isolation. Included functions: Static pressure port. Damper control with damper position indicator. Overall efficiency test: downstream sample port. Ports: Chrome-plates brass quick disconnect. For filters: MEGALAM HFU H14 or U15 gel seal MD, MX and MG depth. Filter seal: Immediate airtight seal by knife edge technology and gel seal filters. Filter mounting: Quick filter change by pre-positioned rotating clamps. Controls: Individual MPPS scanning, EN 1822 individual test report in the box. Fastening: Suspended or fixed by 4 hanging pads. Grille: Stainless steel 304 flush perforated hinged grille, 40% open with 38mm removable trim. Supply Unit With simplified control set: static pressure port, damper control, no aerosol dispersion port Reference Type Model Dimensions (WxHxD) mm 5502.03.12 Pharmaseal 6P6 PH-25D25D-12D-D-F-12-R-TS-A-C-2-D-2-A-2 641x641x311/305 13 0,17 5502.05.12 Pharmaseal 12P6 PH-25D49D-12D-D-F-12-R-TS-A-C-2-D-2-A-2 641x1251x311/305 25 0,34 Exhaust Unit With complete control set: static pressure port, damper control, overall efficiency port Reference Type Model Dimensions (WxHxD) mm 5502.03.50 Pharmaseal 6P6 PH-25D25D-12D-D-F-12-R-TS-A-C-0-C-2-A-2 641x641x311/305 13 0,17 5502.05.50 Pharmaseal 12P6 PH-25D49D-12D-D-F-12-R-TS-A-C-0-C-2-A-2 641x1251x311/305 25 0,34 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 78 Unit weight kg Unit volume m 3 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Unit weight kg Unit volume m 3 W D • Contact free filter change • Sealed, welded, solid design • Automatic tension regulating • Tightness class B as per EN filter clamping device • Fast secure filter installation, lever operated • Optional filter seal seating test as per DIN 1946, Part 4 1866 at 5000 Pa • Ready flanged • CamSafe connecting pieces can be supplied in various designs Application: CamSafe chambers are used when filtering radioactive, toxic or bacterial particles and gasses and provide maximum safety for the operator. Areas of use include laboratories, isolation wards and the pharmaceutical industry. The casings can be joined together so that Dimensions prefilter (WxHxD) mm Dimensions second filter (WxHxD) mm 730x535x725 (+ 90*) - 610x610x292 50 0,35 730x790x725 (+ 90*) 610x610x47 610x610x292 80 0,55 Camsafe P2/1000, painted 730x1020x725 (+ 90*) 610x610x292 610x610x292 90 0,7 5180101 Camsafe 1000 1.4301 730x535x725 (+ 90*) - 610x610x292 50 0,35 5180141 Camsafe P1/1000 1.4301 730x790x725 (+ 90*) 610x610x47 610x610x292 80 0,35 5180181 Camsafe P2/1000 1.4301 730x1020x725 (+ 90*) 610x610x292 610x610x292 90 0,7 Reference Type Dimensions (WxHxD*) mm 518010 Camsafe 1000, painted 518014 Camsafe P1/1000, painted 518018 Unit weight kg Unit volume m3 Filter Frames and Housings * incl. male thread hand knobs + 90mm. Allow access of approximately 1m to change the filter. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 79 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. multi-stage filter systems with a volume flow of up to 24,000 m3/h can be achieved. Epoxy coated casing: Epoxy resin coating in RAL 9010 which is capable of being decontaminated, clamping device made from high grade steel 1.4301. Steel casing: Manufactured in high grade steel 1.4301. Standard design: Material thickness 2mm, flange drilled ready for operation, service cover with male thread hand knobs, changing bag, support shelf for contact free filter changing, automative tension regulating filter clamping device. Options: Filter seal seating test device in accordance with DIN 1946 Part 4, pressure compensation device and pressure check points. Filter cartridges: Prefilter P1: 610x610x47mm . Prefilter P2: 610x610x292mm. Main filter: 610x610x292mm. All main filters come equipped with straps to aid the handling, enabling them to be changed easily. The filters can be supplied with a variety of gaskets to suit the application. The casing is suitable for different classes of filter, suitable for dealing with glasses or particle contamination. Accessories: Safe change bags, manometers and material for the flanged joints supplied on request. Bag and Compact Filters, Class F5 to F9 Advantages H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Camsafe Carbon and Chemical Filters Filter Containment Systems Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Housings, frames & special applications Housings, frames & special applications F i l t e r s f o r H i g h Te m p e r a t u r e Termikfil 2000 Advantages W D • Meets FDA requirements - • Exclusive precuring process continuous 350°C, 99,99% at 0,3 μm • Efficiency tested after precuring at 300°C carried out in the plant • Ceramic frame Application: Protection of ultra-clean processes at high temperature, sterilisation tunnels in the pharmaceutical industry. Type: Very high efficiency panel resistant to 350°C in continuous service. Frame: Composite ceramic. Gasket: Rolled glass fibre paper + 6mm dia glass braid. Media: Glass fibre. Separator: Glass strands. Sealant: Ceramic. Grid: Upstream and downstream in stainless steel. DOP efficiency: ≥ 99.99%. Type Model Dimensions (WxHxD) mm Filter classification EN 1822 Media area m 2 Air flow/pressure drop m 3 /h/Pa Unit weight kg Unit volume m 3 3415.07.00 TERMIKFIL 4P4 457x457x84 99.9 5.0 675/250 3 0.04 3415.06.00 TERMIKFIL 3P3 305x305x84 99.9 2.9 300/250 2 0.01 3415.01.00 TERMIKFIL 3P6 305x610x84 99.9 5.9 600/250 4 0.02 3415.02.00 TERMIKFIL 6P6 610x610x84 99.9 12.1 1200/250 5 0.04 3415.05.00 TERMIKFIL 4P6 457x610x84 99.9 8.9 900/250 4 0.03 3415.03.00 TERMIKFIL 7P6 762x610x84 99.9 15.3 1500/250 6 0.05 3415.04.00 TERMIKFIL 9P6 915x610x84 99.9 18.5 1800/250 8 0.06 References Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 80 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Authorised local penetration: 10 -4 maximum, (0.01% conforming to FDA). Recommended final pressure drop: 350 Pa. Temperature: Up to 350°C in continous service. Test: 100% after thermal treatment at 300°C. Mounting: A stainless steel compensating frame can be supplied to reach the thickness of 150mm or 292mm. NB: To reduce fume emission when starting up, TERMIKFIL undergoes a specific precuring cycle in the factory at 300°C using an exclusive CAMFIL FARR process. Absolute ® 1FRK Advantages • 99.97% DOP • High temperature resistant (up to 350°C) Application: Protection of ultra-clean processes at high temperatures. Frame: Stainless steel. Gasket: Glass fibre. Media: Glass fibre paper. Separator: Aluminium. Sealant: Ceramic, glass fibre. DOP efficiency: 99.97% . Temperature: 350°C in continuous service (400°C peak). W D Type Model Dimensions (WxHxD) mm Filter classification EN 779:2002 Media area m 2 213612F2 Absolute 1 FRK 1FRK-220-10 305x610x150 99.97 5.1 580/250 6 0.04 213024F1 Absolute 1 FRK 1FRK-300-10 457x457x150 99.97 6.8 1125/250 8 0.05 213014F2 Absolute 1 FRK 1FRK-150-10 457x610x150 99.97 8.0 900/250 10 0.07 213017F2 Absolute 1 FRK 1FRK-600-10 610x610x150 99.97 11.0 1245/250 12 0.07 213019F2 Absolute 1 FRK 1FRK-980-01 914x610x150 99.97 16.8 1925/250 16 0.11 213003F2 Absolute 1 FRK 1FRK-450-01 305x610x150 99.97 10.4 950/250 9 0.06 213021F2 Absolute 1 FRK 1FRK-725-01 610x457x292 99.97 16.4 1500/250 13 0.08 213010F1 Absolute 1 FRK 1FRK-1250-01 762x610x292 99.97 28.4 2625/250 21 0.17 213008F2 Absolute 1 FRK 1FRK-1000-01 610x610x292 99.97 22.5 2050/250 17 0.12 Air flow/nominal Unit weight kg pressure drop m 3 /h/Pa H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Unit volume m3 Reference Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 81 A i r F i l t e r Te c h n o l o g y Filter Frames and Housings Carbon and Chemical Filters Model 01 = seal on air inlet side - Model 02 = seal on air outlet side - Other dimensions available on request As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Bag and Compact Filters, Class F5 to F9 F i l t e r s f o r H i g h Te m p e r a t u r e Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Housings, frames & special applications Housings, frames & special applications Filters for Painting Booths Paint Extract Filters Advantages • Long lasting solution • Effective for a variety of contaminants • Collapsible for transportation TIFICAT ER E C Application: Collection of overspray particles, paint booth exhaust Type: Concertina pleated cardboard filter Case: Cardboard Media: Cardboard or two stage cardboard and synthetic media Efficiency: See table Recommended final pressure drop: 130 Pa (suggested economical change point) Temperature: 180°C maximum in continuous service (standard grade) 100°C maximum in continuous service (two stage grades) EN 779:2002 DU ALLY CER TI F Reference Type Model Dimensions (WxL) m Air flow/ Pressure drop m 3 /hr/Pa Unit weight kg AND 1 Standard AND 1 - 3 x 30 0.9 x 9.15 2700 / 30 9.80 AF Basic Standard AF Basic 3 x 30 0.9 x 9.15 2700 / 30 9.80 HEF 1330 Two Stage HEF 1330 - 3 x 30 0.9 x 9.15 2700 / 40 11.20 Performance data Standard type Two stage type Paint type Filtration efficiency (%) Holding capacity (kg) Filtration efficiency (%) Holding capacity (kg) High Solids 97.0 - 98.1 14 - 18 98.75 - 99.1 16 - 24 Bake Enamel 93.0 - 94.5 6 - 11 97.8 - 91.15 7 - 14 Fast Dry Enamel 96.0 - 96.9 3-4 98.0 - 92.2 4-6 Two Component Epoxy 91.0 - 93.5 5-8 n/a n/a Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 82 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. DI IE D IN VI Camfil Farr Solutions Housings, frames & special applications Filters for Painting Booths Airopac ® HT-HF DU ALLY CER TI F W D Pre-Filtration, Class G3 to F5 • Compact design Application: Paint bake ovens. Type: High efficiency, high temperature, silicon free compact filter. Frame: Galvanised steel. Gasket: Glass fibre. Media: Glass fibre paper. Separator: Corrugated aluminium. Sealant: Glass fibre . Grid: Galvanised steel grille upstream and downstream. EN 779:2002 efficiency: F6, F8. Opacimetric efficiency: > 60%, >90%. Recommended final pressure drop: 300 Pa. Temperature: 220°C maximum continuous, 250°C peak during 1 hour. Dimensions (WxHxD) mm Filter classification EN 779:2002 Media surface m 2 1519.77.03 3CPMHT-HF-242412-60 592x592x292 F6 13.3 3600/110 9 0.10 1520.27.03 3CPMHT-HF-242412-90 592x592x292 F8 13.3 3600/155 9 0.10 Reference Model Air flow/nominal pressure drop m 3 /h/Pa unit Unit weight kg volume m 3 Carbon and Chemical Filters Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Other dimensions available on request. Also available in version without flange, for more information please contact us. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 83 A i r F i l t e r Te c h n o l o g y DI IE D IN VI • Silicon free construction • High temperature Bag and Compact Filters, Class F5 to F9 EN 779:2002 • High efficiency H E PA / U L PA F i l t e r s , C l a s s H10 to U17 TIFICAT ER E C Advantages Housings, frames & special applications Filters for Painting Booths Panolair SSI - Micretain H10 Advantages • Compact design • Guaranteed silicone free • Meets the requirements of the • Very high efficiency H10 Application: Final filtration in painting booths. Type: High efficiency pleated paper filter. Case: Anodised aluminium extrusion. Media: Glass fibre. Sealant: Polyurethane. Separator: Strips of glass paper. Grid: Painted steel grilles upstream and downstream. EN 1822 efficiency: H10. MPPS efficiency: ≥ 85%. Efficiency DOP 0.3μ: ≥ 95%. Temperature: 70°C in continuous service. Holding frames: Mechanical clamping structure, terminal diffusers. TIFICAT ER E C surface treatment industry EN 779:2002 DI IE D IN VI DU ALLY CER TI F W D Unit Filter classification Media Airflow / pressure Unit EN 1822 area m 2 drop / m 3 /h/Pa weight kg volume m 3 Reference Type Model Dimensions (WxHxD) mm 3409.48.00 Panolair Micretain 0.3 m/s 610x1285x44 H10 8.1 1000/110 8.0 0.04 3409.73.00 Panolair Micretain 0.5 m/s 610x610x44 H10 5.2 650/120 4.0 0.02 3409.31.00 Panolair Micretain 0.5 m/s 610x1220x44 H10 10.5 1200/120 6.5 0.04 3409.45.00 Panolair Micretain 0.5 m/s 610x1285x44 H10 11.1 1500/120 8.0 0.04 Other sizes available on request . Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 84 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Also available in F8 and F9 grades. Camfil Farr Solutions Housings, frames & special applications Filters for Painting Booths CDM Media Advantages EN 779:2002 DU ALLY CER TI F Application: For fine filtration in air conditioning devices and installations, particularly final filtration in Automotive spraybooths and drying cabinets. Flammability: (DIN 53438) F1 self extinguishing. Colour: White. Media: Synthetic. EN 779:2002 efficiency: F5. Arrestance efficiency: 95%. Temperature: 80°C - 100°C maximum in continuous service. Humidity: 80 - 100% RH. Reference Type Model Dimensions (meters) Filter classification EN 779:2002 Media area m 2 Velocity/pressure drop m/s/Pa Dust Unit holding volume m3 g/m² Rear support scrim TA500220 Roll TA-500 2.0 x 20 F5 40 0.25 / 54 223 0.53 no TA500120 Roll TA-500 1.0 x 20 F5 20 0.25 / 54 223 0.26 no TA600GI220 Roll TA-600 GI 2.0 x 20 F5 40 0.25 / 45 291 0.82 yes TA600GI1620 Roll TA-600 GI 1.6 x 20 F5 32 0.25 / 45 291 0.4 yes TA600GI120 Roll TA-600 GI 1.0 x 20 F5 20 0.25 / 45 291 0.304 yes SPEU480220 Roll SPEU-480 2.0 x 20 F5 40 0.25 / 23 399 0.615 yes Carbon and Chemical Filters Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Other sizes and cut pads available on request. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 85 A i r F i l t e r Te c h n o l o g y DI IE D IN VI patterns • Non toxic H E PA / U L PA F i l t e r s , C l a s s H10 to U17 TIFICAT ER E C prevent dust loss due to vibration • Enhances laminar air flow Pre-Filtration, Class G3 to F5 • Treated with special adhesive to Bag and Compact Filters, Class F5 to F9 • Thermal bonded polyester fibre Housings, frames & special applications F i l t e r s f o r G a s Tu r b i n e s Cam GT ® Advantages W D • Suitable for high humidity • Very robust construction conditions • Burst pressure 7500 Pa • Patented draining pleating • Corrosion resistant • Can be used to upgrade existing installations Application: Air intake for gas turbines, compressors and large engines. Type: High efficiency, incinerable compact filter. Frame: Polypropylene and ABS. Gasket: Expanded polyurethane placed on the downstream side (code 01). Media: Glass fibre paper. Separator: Hot-melt beads. Sealant: Polyurethane. Grid: Glass fibre reinforcement grid placed downstream. EN 779:2002 efficiency: F7. F9. EN 1822 efficiency: H10. Recommended final pressure drop: 600 Pa. Temperature: 80°C maximum in continuous service. N.B: Burst pressure: > 7500 Pa. EFFICIENCY GUARANTEE Unit Type Model Dimensions (WxHxD) mm Filter classification EN 779:2002 Media area m² Air flow/pressure drop Unit weight Unit Volume m³/h/Pa kg m³ 1530.12.50 CAM GT-F7 CAM GT F7-242412/01 592x592x290 F7 19 4250/120 7 0.11 B 1530.17.50 CAM GT-F9 CAM GT F9-242412/01 592x592x290 F9 19 4250/160 7 0.11 B 1530.18.50 CAM GT-H10 CAM GT H10-242412/01 592x592x290 H10 19 4250/230 7 0.11 1530.52.50 CAM GT-F7 CAM GT F7-241212/01 592x287x290 F7 9 2125/145 5 0.05 B B 1530.57.50 CAM GT-F9 CAM GT F9-241212/01 592x287x290 F9 9 2125/180 5 0.05 1530.58.50 CAM GT-H10 CAM GT H10-241212/01 592x287x290 H10 9 2125/250 5 0.05 Available with gasket on upstream side (10). Available in reverse flow version. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 86 Energy Rating As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Reference Camfil Farr Solutions Housings, frames & special applications F i l t e r s f o r G a s Tu r b i n e s Campulse EF Advantages F Recommended air flow per set of cartridges CY-2612/CO-2612: 2500 m3/h. Temperature: 80°C max. Degradation pressure: 10kPa. Shipping data Media area Air flow/Pressure drop m 3 /h/Pa Filter classification m 3 / Kg 660 324 21.40 1062/211 F9 0.076 7 660 445/324 25.41 1261/211 F9 0.142 9 Carbon and Chemical Filters CY-2612 CO-2612 Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. ALLY CE I RT Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 87 A i r F i l t e r Te c h n o l o g y DI Dimensions mm IE D IN Model DU Bag and Compact Filters, Class F5 to F9 TIFICAT ER E C Type: Single stage, high efficiency Pulse filter cartridge. End Caps: Galvanised steel. Liners: Expanded galvanised steel. Media: Resin impregnated mixture of cellulose and synthetic fibres. Separator: Hot melt beads. Seal: Adhesive bonding layer. Gasket: Closed cell neoprene or equivalent. Eurovent 4/9 efficiency: F9. Recommended final pressure drop: 1000 Pa. EN 779:2002 VI compressors and large engines Pre-Filtration, Class G3 to F5 • Air intake for gas turbines, dusty environments • Desert and arctic environments H E PA / U L PA F i l t e r s , C l a s s H10 to U17 • Specially designed for very Housings, frames & special applications F i l t e r s f o r G a s Tu r b i n e s Hi-Flo ® T Advantages • Reinforced filter media • Rigid design concept • Suitable for turbulent air flow • High burst strength conditions W Application: Turbo machinery. Type: Multi pocket high efficiency bag filter. Frame: 25mm thick steel header frame. Media: Glass fibre. EN 779:2002 efficiency: F6, F7, F8. Arrestance efficiency: 55-65%, 80-85%, 90-95%. Temperature: 70°C maximum in continuous service. Humidity: 100% RH. Burst Pressure: ~3000 Pa. D EFFICIENCY GUARANTEE Reference Type Model Dimensions (WxHxD) mm Filter classification EN 779:2002 538012A1 Hi-Flo T 3 XMT-65 592x592x655 F6 7.8 3400/70 5.0 0.05 538013A1 Hi-Flo T 3 ZMT-65 287x592x655 F6 3.9 1700/70 3.0 0.03 538012A2 Hi-Flo T 3 XMT-85 592x592x655 F7 7.8 3400/90 5.0 0.05 538013A2 Hi-Flo T 3 ZMT-85 287x592x655 F7 3.9 1700/90 3.0 0.03 538012A3 Hi-Flo T 3 XMT-95 592x592x655 F8 7.8 3400/115 5.0 0.05 538013A3 Hi-Flo T 3 ZMT-95 287x592x655 F8 3.9 1700/115 3.0 0.03 Other dimensions available on request. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 88 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Media area Air flow / pressure drop Unit weight Unit Volume m 3 kg m2 m 3 /hr/Pa Camfil Farr Solutions Housings, frames & special applications Dust Collector Gold Series Advantages • Simple cartridge replacement using quick release cam bars Application: Gold Series cartridge dust and fume collectors may be used for a wide range of pollution control and product recovery applications. Type: Pulse cleaning, cartridge based dust collector with high performance filter elements. Cleaning is accomplished by pulse waves that emanate from the centre of the filter providing enhanced cleaning for a more efficient operation. Construction: Strong modular construction using 4.5mm carbon steel for the frame and 3mm carbon steel for the doors, hopper and panels. Finish: As standard in a green, durable, corrosion resistant powder coated finish. Alternative construction and colours are also available. Options: A wide variety of options are available including: Explosion Venting, Special Inlet Designs, BIBO (bag in-bag out) for Pharmaceutical Applications, Custom Colours, Stainless Steel Construction, Alternative Hopper Designs etc. please contact us with your specific requirements. Cartridges: Vertically mounted to shed dust readily for efficient cleaning and longer service life. High filtration efficiency meeting the 5 mg/m3 or less emissions required to re-circulate the air back into the work place on non hazardous dusts. Carbon and Chemical Filters Easy Changeout Gold Cone Cartridge with patented Cambar action that positively seals the cartridges without using threads or knobs. Powerful Cleaning System to Provide Long Filter Life High Entry Inlet Cross flow is created through the filters. Eliminates upward “can” velocities associated with traditional hopper inlets. Filter Frames and Housings Optional Quick Open View Port in Hopper Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 89 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Easy Access Door • No Knobs To Lose or Drop • No Threads To Bind • Mechanically Attached Seal • Heavy 10 gauge Construction • Lock-Out/Tag-Out Capability Bag and Compact Filters, Class F5 to F9 flexibility • Easy to install and maintain Pre-Filtration, Class G3 to F5 • Modular design for optimum HemiPleat cartridges • Up to 25% smaller • Customised for Original Equipment Manufacturers (OEM) H E PA / U L PA F i l t e r s , C l a s s H10 to U17 • High collector efficiency using Housings, frames & special applications Dust Collector HemiPleat Cartridges Advantages • High efficiency, 99.999% at • Open pleat spacing to enhance 0.5μ and above • Low pressure drop • Reduced energy cost • Long filter life cleaning cycle • Easy to install using quick release cam bars • Double seal gasket for added security Media Type Dimensions (dia. x L) mm Media area m 2 Unit weight kg 211497-001 HemiPleat HMPTS325 PolyTech Standard 380 x 1000 30.2 13.6 211497-002 HemiPleat HMPTC325 PolyTech Carbon Impregnated 380 x 1000 30.2 13.6 211497-004 HemiPleat HMPTF325 PolyTech Fire Retardant 380 x 1000 30.2 13.6 211497-005 HemiPleat HMPTU325 Poly Tech Ultra High Efficiency 380 x 1000 30.2 13.6 211497-006 HemiPleat HMPTUF325 Poly Tech Ultra High Efficiency Fire Retardant 380 x 1000 30.2 13.6 Reference Type Model Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 90 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Application: HemiPleat cartridges may be used for a wide range of pollution control and product recovery applications. Type: Pleated media cartridge with improved pleat spacing and media alignment. Construction: Vertically mounted to shed dust readily for efficient cleaning and longer service life. Features a cone in the centre of the cartridge to distribute the air pulse and enhance the cleaning cycle. Media: Several different types of filter media, pre-coat materials and over bags are available to suit specific operating conditions. Please contact us to make this selection. Efficiency: 99.999% at 0.5μ and above. Options: Filter cartridge options are available to suit specific operating conditions. These include Carbon Impregnated, Fire Retardant, Ultra High Efficiency, PTFE, and High Temperature. Please contact us to make this selection. Carbon and Chemical Filters H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Bag and Compact Filters, Class F5 to F9 Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Notes Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 91 A i r F i l t e r Te c h n o l o g y Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Housings, frames & special applications A i r F i l t e r Te c h n o l o g y Standards, Regulations and Recommendations Ventilation filters Classification as per Eurovent 4/4 recommendation, NaCI method EUROVENT 4/4 Year Reference Type of test Classification 1968 ASHRAE ARRESTANCE EFFICIENCY 1980 EUROVENT 4/5 ARRESTANCE EFFICIENCY 1982 AFNOR NF X 44.012 ARRESTANCE EFFICIENCY 1993 CEN EN 779 ARRESTANCE EFFICIENCY G1 to G4 - F5 to F9 2003 CEN EN 779:2002 ARRESTANCE EFFICIENCY G1 to G4 - F5 to F9 EU1 to EU4 - EU5 to EU9 The new standard for general ventilation filters EN 779:2002 1. Measurement of filter efficiency using modern particle counting technique 2. The aerosol challenge is DEHS (the same as used with HEPA filters) 3. Classification based on a particle size of 0.4 μm 4. The test includes initiatives to determine the discharged efficiency of filters to better represent their performance in use. These are shown in Annexe A. Initial efficiency Ei (%) Filter class Penetration Pi (%) Limits of filter classes EU 10 95 ≤ Ei < 99.9 5 ≥ Pi > 0.1 EU 11 99.9 ≤ Ei < 99.97 0.1 ≥ Pi > 0.03 EU 12 99.97 ≤ Ei < 99.99 0.03 ≥ Pi > 0.01 EU 13 99.99 ≤ Ei < 99.999 0.01 ≥ Pi > 0.001 EU 14 99.999 ≤ Ei 0.001 ≥ Pi Clean rooms Classification of different air qualities required for manufacture of sterile products Maximum number of particles per m 3 of a size greater than or equal to 0.5 μm 5 μm 0.5 μm inactive (b) 5 μm Max. nbr: of μorganisms per m³ (active) <1 active Why a new standard? A 3.500 0 3.500 0 Certain types of filter media rely on an electrostatic effect to achieve a high level of efficiency whilst promising a low pressure drop for a given air volume. B 3.500 0 350,000 2.000 10 C 350,000 2.000 3.500,000 20,000 100 not defined (c) 200 It is important that users are aware of filters that rely on this electrostatic effect and are also informed about the degradation in efficiency once the electrostatic effect dissipates. This new test procedure describes in Annexe ’A’ a mechanism that removes the electrostatic effect by treating the filter material with Isopropanol. This discharges the filter and enables the real efficiency to be determined. The average efficiency of the filters after discharge is recorded on the certificate. Filters are classified based on their performance against particles of 0.4 μm. Filters in Group F must achieve an average efficiency greater than 40%; below this they are included in Group G. EN 779:2002 Classification EN 779:2002 standard Average arrestance Am (%) Average efficiency Em (%) D 3.500,000 20,000 not defined (c) Pharmaceutical industry Guide to good Manufacturing Practice (2002) (b) Corresponds approximately to the US Federal Standard 209 E and ISO as follows: classes A and B to class 100. M 3.5. ISO 5; class C to class 10,000. M 5.5. ISO 7; class D to class 100.000. M 6.5 ISO 8. Comparison of international classification standards Nbr of part 0.5 μm/ m³ (approx.) EN ISO 14644-1 1996 US Fed. Std 209 E 1992 European Union Pharma industry Guide GMP 1989 France AFNOR NF X 44.101 1981 Nbr of part 0.1 μm/ m³ (approx.) - - - ISO 1 - - 10 1 - - - - - 35 4 - - ISO 2 - - 100 EUROVENT 4/5 equivalent 10 M1 - - - - 350 35 M 1.5 1 ISO 3 - - 1,000 Filter class 100 M2 - - - - 3,500 Filter group Filter class G2 65 ≤Am < 80 - EU 2 353 M 2.5 10 ISO 4 - - 10,000 Coarse (G)* G3 80 ≤Am < 90 - EU 3 1,000 M3 - - - - 35,000 G4 90 ≤Am - EU 4 F5 - 40 ≤Em < 60 EU 5 F6 - 60 ≤Em < 80 EU 6 F7 - 80 ≤Em < 90 F8 - F9 - Fine (F) ** Filter class limits MIL STD 282 DOP 4,000 A and B 100,000 - - - 350,000 1.000,000 1.000 ISO 6 - - M5 - - - - - EU 7 353,000 M 5.5 10,000 ISO 7 400,000 C - 90 ≤Em < 95 EU 8 1.000,000 M6 - - - - - 95 ≤Em EU 9 3.530,000 M 6.5 100,000 ISO 8 4.000,000 D - 10,000,000 M7 - - - - - 35.000,000 - - ISO 9 - - - Permissible particle levels in different classes of clean rooms and clean zones Standards 1956 ISO 5 - M 4.5 Very high efficiency filters Type of test 100 M4 35,300 Final pressure drop: * 250 Pa ; ** 450 Pa Reference M 3.5 100,000 Initial efficiency (Ea) : * Ea < 20% ; ** Ea ≥20% Year 3,530 10,000 Classification 0.3 μm ISO classification CD 14644-1 (1996) - Maximum permissible concentrations (particles/m³ of air) of particles of a size greater than or equal to the size shown below 0.1 μm 0.2 μm 0.3 μm 0.5 μm 1 μm 10 2 - - - 5 μm - 100 24 10 4 x - 1972 AFNOR NF X 44.011 Uranine 0.15 μm - ISO 1 1976 EUROVENT 4/4 NaCl 0.65 μm EU10 to EU14 ISO 2 237 102 35 8 - MPPS HEPA: H10 to H14 ULPA: U15 to U17 1,000 CEN EN 1822 0.1 to 0.2 μm ISO 3 1995 ISO 4 10,000 2,370 1,020 352 83 - 23,700 10,200 3,520 832 29 237,000 102,000 35,200 8,320 293 EN 1822 Classification MPPS integral values Minimum Maximum Minimum efficiency penetration P.C. (%) (%) HEPA (H) H10 85 15 6.7 H11 95 5 20 H12 99.5 0.5 200 H13 99.95 0.05 2.000 H14 99.995 0.005 20,000 ULPA (U) U15 99.9995 0.0005 200,000 U16 99.99995 0.00005 2.000,000 U17 99.999995 0.000005 20,000,000 HEPA : High Efficiency Particulate Air (filter) ULPA : Ultra Low Penetration Air (filter) P.C. : Purification Coefficient Filter group Filter class MPPS local values Minimum Maximum efficiency penetration Minimum P.C. (%) (%) 99.75 0.25 400 99.975 0.025 4.000 99.9975 0.0025 40,000 99.99975 0.00025 400,000 99.9999 0.0001 1.000,000 ISO 5 100,000 ISO 6 1.000,000 ISO 7 - - - 352,000 83,200 2,930 ISO 8 - - - 3.520,000 832,000 29,300 ISO 9 - - - 35.200,000 8.320,000 293,000 C = 10N(0.1/D)2.08 part / m3 Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 92 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. Standards Operating life Class Name 0.1 μm 0.2 μm 0.3 μm 0.5 μm 5 μm An air filter’s operating life is not directly proportional to its useful filtering surface. It is much better to opt for a model comprising 50% additional surface. This increases its operating life by 100%, not 50%! Volume Units Volume Units Volume Units Volume Units Volume Units S1 English m3 m3 m3 m³ m³ M1 - 350 75.7 30.9 10.0 - M 1.5 1 1,240 265 106 35.3 - Filter model Effective filtering surface Initial pressure drop at 3 600m³/ h Operating life* M2 - 3,500 757 309 100 - Hi-Flo 3P 85 6.5 m2 120 Pa 3.500 hours M 2.5 10 12,400 2,650 1,060 353 - Hi-Flo 3M 85 100 Pa 6.500 hours M3 - 35,000 7,570 3,090 1,000 - 9.4 m2 Gain 3 m2 20 Pa 3.000 hours Conclusion + 46% in surface (x 1.5)** - 17% in energy + 86% in operating life (x 1.9)** Actual case study M 3.5 100 - 26,500 10,600 3,530 - M4 - - 75,700 30,900 10,000 - M 4.5 1000 - - - 35,300 247 M5 - - - - 100,000 618 M 5.5 10,000 - - - 353,000 2,470 M6 - - - - 1.000,000 6,180 M 6.5 100,000 M7 - - - - 3.530,000 24,700 - - - 10,000,000 61,800 * Determined using the Camfil Farr calculation charts in the Hi-Flo brochure, for an average town environment ** factor of increase Energy costs Energy consumed by an air filter due to its pressure drop: particles / m3 = 10M(0.5/d)2 . 2 particles / ft3 = Nc(0.5/d)2 . 2 Air-conditioning / Comfort Bag and Compact Filters, Class F5 to F9 The Efficiency % The Penetration % Air quality of premises with non specific pollution Fresh air The Purification coefficient (no units) Regulatory aspect Recommendations Labour code / Circular of application of decrees 84/10931094 dated 7/12/1984 UNICLIMA Air-conditioning & Health guide (1993) Labour code Art. R235.2.6 Air-conditioning system inlet: 85% opacimetric (F7 Minimum arrestance according to EN 779:2002) Air-conditioning system efficiency 90% (G4 according outlet: 90% opacimetric (F8 according to EN to EN 779:2002) 779:2002) Labour code Art. R232.5.4 Minimum opacimetric Recycled air efficiency 50% (F5 according to EN 779:2002) 85% opacimetric (F7 according to EN 779:2002) FILTER ENGINEERING - Calculations Acronyms and abrivations AFNOR French standardisation body ASHRAE American Society of Heating, Refrigerating and Air-conditioning Engineers (USA) ASPEC Association for prevention and study of contamination (France) An air filter’s efficiency is expressed in 3 forms: BSI British Standards Institute formulas CEN European standardisation body CETIAT Technical centre for air handing and thermal industries (France) CNC Condensation Nucleus Counter q x dP x h = kWh E= ef x 1000 Clearly the purification coefficient is the most representative expression for high levels of filtration. E.g.: Efficiency 99.995 % : CE of 20,000 Efficiency 99.9998% : CE of 500 000 The second filter is 25 times more efficient than the first. Nota : I = particle concentration upstream E = particle concentration downstream Conversion table (%) Efficienc y 95 Penetration Purification Coefficient Efficiency Penetration Purification Coefficient 0.01 10,000 5 20 99.99 VOC Volatile Organic Compounds CSTB Scientific and technical centre for construction (France) DEHS Di-Etil-Hexil-Sebaçate (= DES = DOS) DIN Deutsches Institut für Normung DOP Di-Octil-Phtalate EUROVE NT European Committee of Manufacturers of Air Handing Equipment Arrest Arrestance efficiency HEPA High Efficiency Particulate Air (filter) ISO International Standards Organisation MPPS Most Penetrating Particle Size Opa Opacimetric efficiency ULPA Ultra Low Penetration Air (filter) 1 100 99.995 0.005 20,000 UNICLIM A Association for refrigeration equipment and air handing equipment (France) 0.5 200 99.999 0.001 100,000 VTT Technical research centre (Finland) 99.9 0.1 1.000 99.9995 0.0005 200,000 dP Pressure drop 99.95 0.05 2.000 99.9999 0.0001 1.000,000 99.97 0.03 3 333 99.99995 0.00005 2.000,000 99.98 0.02 5 000 99.99999 0.00001 10,000,000 Filter Frames and Housings 99 99.5 Comperative efficiencies on 1 μm on 0.5 μm E P PC E P PC 5% 95% 1.05 1.1 90% ARRESTANCE 10% 90% 1.1 50% EFFICIENCY 30% 70% 1.4 10% 90% 65% EFFICIENCY 45% 55% 1.8 25% 75% 1.3 85% EFFICIENCY 85% 15% 6.6 70% 30% 3.3 95% EFFICIENCY 95% 5% 20 90% 10% 10 95% 0.3 μm ≥ 98% < 2% ≥100 ≥98% <2% ≥ 50 E = Efficiency, P = Penetration, PC = Purification Coefficient Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 93 A i r F i l t e r Te c h n o l o g y As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. q = flow rate (m3/s) dP = pressure drop (Pa) h = operating period (hours) ef = fan efficiency (generally 0.6 to 0.7) H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Class Limits Carbon and Chemical Filters US Fed Std 209 E (1992) Camfil Farr Solutions Standards, Regulations and Recommendations Pre-Filtration, Class G3 to F5 A i r F i l t e r Te c h n o l o g y A i r F i l t e r Te c h n o l o g y Standards, Regulations and Recommendations EFFICIENCY TESTS (Not all the tests are equivalent) Conversions Speed 1 m/s = 3.6 km/h 1 km/h = 0.278 m/s 1 ft/min = 0.00508m/s 1 m/s = 196.85 ft/min 1 mile = 1.609 km 1 km = 0.621 mile 1 yd = 0.914 m 1 m = 1.09 yd 1 ft = 0.305 m 1 m = 3.28 ft 1 in = 25.4 mm 1 mm = 0.039 in 1 mm = 1.000 μm 1 μm = 0.001 mm 1 μm = 1.000 nm 1 nm = 0.001 μm 1 μm = 10,000 Å 1 Å = 0.0001 μm 1 m² = 10.8 ft² 1 in² = 6.45 cm² 1 cm² = 0.155 in² 1 m³ = 35.3 ft³ 1 ft³ = 28.3 litres MPPS (Most Penetrating Particle Size) Length 0.01 0.1 0.05 0.3 0.5 Surface 1 ft² = 0.0929 m² Volume 1 ft³ = 0.0283 m³ Flow rate 1 cfm = 0.472.10 -3 m³/s 1 m³/s = 3 600 m³/h 1 cfm = 1.699 m³/h 1 m³/s = 2 120 cfm 1 m³/h = 0.278.10 -3 m³/s Weight 1 lb = 0.454 kg 1 kg = 2.20 lb 1 oz = 28.3 g 1 g = 0.0352 oz 1 N = 0.102 kgf 1 lbf = 4.45 N 1 N = 0.225 lbf 1 mmCE = 9.81 Pa 1 Pa = 0.102 mmCE 1 kPa = pz 1 kPa = 10.2 g/cm² 1 kg/cm² = 0.980665 bar 1 bar = 1.02 kg/cm² 1 kg/m² = 98.0665 kPa 1 kPa = 0.00987 atm 1 psi = 6.89 kPa 1 bar = 101325 Pa 1 atm = 101.325 kPa 1 mb = 100 Pa 1 mmCE = 1kg/m² 1 kPa = 0.145 psi 1 Pa = 1 N/m² 1 in w.g. = 254 Pa 1 kgm = 9.80665 J 1 J = 0.102 kgm 1 cal = 4.184 J 1 J = 0.239 cal 1 kWh = 3.6 MJ 1 MJ = 0.278 kWh 1 Btu = 1.055 kJ 1 J = 0.945.10-3 Btu 1 CV = 0.736 1 kW = 1.36 CV 1 kcal/h = 1.16 W 1 W = 0.860 kcal/h 1 Btu/h = 0.292 W 1 W = 3.42 Btu/h Force 1 kgf = 9.80665 N The NaCl test (EUROVENT 4/4) is less demanding than the DOP test, which in turn is less demanding than the MPPS test Pressure Whitby diagram Distribution of particles in atmospheric air Energy Nombre (1) (1) Number Power Surface (2) Temperature: conversion formulae 0 °C = 32 °F 0 °F = -17.8 °C °F = (9/5) x °C +32 °C = (5/9) x °F -17.8 Poids (3) Weight Temperature: conversion table °F °C °F °C °F °C °F °C 0 -17,8 30 -1,1 50 10,0 80 26,7 10 -12,2 32 0 60 15,6 90 32,2 20 -6,7 40 4,4 70 21,1 100 37,8 Diameter of particles (µm) Energy 1 J/kg = 0.239.10-3 kcal/kg Heat transmission 1 kcal/h.m².°C = 1.16 W/(m².°C) 1 W/(m².°C) = 0.86 kcal/h.m².°C 1 Btu/(h.ft².°F) = 5.64 W/(m².°C) 1 W/(m².°C) = 0.177 Btu/(h.ft².°F) FILTER ENGINEERING - Theory Diagram of Whitby: This diagram shows that more than 99.90% of airborne particles are less than or equal to 1 μm in size. Therefore, the essential part of air filtration’s activity takes place in the invisible domain (human ocular partition power: 30 μm). Diagram of particle sizes MPPS Minimum efficiency of air filters 0.01 0.1 0.2 The overall efficiency of an air filter is the result of a combination of 4 basic filtration mechanisms (sieving, inertia, interception and diffusion), so that the efficiency curve of an air filter adopts a characteristic V shape showing a minimum level of efficiency. This minimum efficiency corresponds to a particle size called MPPS (Most Penetrating Particle Size). In other words, the MPPS is the particle size that is the most difficult to stop. The MPPS is situated between 0.1 and 0.2 μm depending on the filter type, and the speed of air flow through the filtering media Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 94 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. 1 kcal/kg = 4.19.103 J/kg Standard terms & conditions for the sale of goods 3. Description 3.1 The description of the Goods and Services shall be as set out in the Company’s quotation. Any Specifications, drawings etc. intended to form part of the Contract will be referred to in the quotation. 3.2 Except where express agreement to the contrary in writing has been made with the Buyer, the Company may make any changes to the specification, design, materials or finishes of the Goods: 3.2.1 which are required to conform with any applicable safety or other statutory requirements; or 3.2.2 which it deems desirable and which do not materially affect their quality or performance. 3.3 No variation in the specification or design of any Goods which, in the Company’s reasonable opinion, does not adversely affect the suitability of the Goods for the particular purpose for which they are supplied by the Company will constitute a breach of contract or impose any liability upon the Company. As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. 4. Delivery of the goods 4.1 Delivery of the Goods shall be made on the basis and at such place as agreed between the parties and as set out by the Company in the written acknowledgement of order in accordance with condition 2.6. 4.2 The Buyer will take delivery of the Goods within 10 days of the Company giving it notice that the Goods are ready for delivery. The Buyer must accept delivery of the Goods and pay for them in full. 4.3 Notwithstanding condition 4.1, any dates specified by the Company for delivery of the Goods are approximate only and may not be made of the essence by notice. 4.4 If the Buyer fails to take delivery of the Goods when they are ready for delivery pursuant to condition 4.1 or to provide any instructions, documents, licences or authorisations required to enable the Goods to be delivered on time (except because of the Company’s fault) risk in the Goods will pass to the Buyer (including, without limitation, for loss or damage caused by the Company’s negligence); the Goods will be deemed to have been delivered and (without prejudice to its other rights) the Company may: 4.4.1 store or arrange for the storage of the Goods until actual delivery or sale and charge the Buyer for all related costs and expenses (including, without limitation, storage and insurance); and/or 4.4.2 following written notice to the Buyer, sell any of the Goods at the best price reasonably obtainable in the circumstances and charge the Buyer for any shortfall below the price under the Contract. 4.5 If carriage is required in accordance with condition 4.5.1 the Goods shall be transported by such means as the Company thinks fit unless the Buyer has specified in its order the details of the contract with a carrier which it reasonably requires having regard to the nature of the Goods and the other circumstances of the case. 4.6 Off-loading by the Buyer 4.6.1 Where it is agreed that the Buyer shall off-load the Goods the Buyer will provide at its expense at the Delivery Point adequate and appropriate equipment and manual labour for off-loading the Goods. 4.6.2 Where condition 4.6.1 applies, the Buyer will indemnify the Company against any liability and expense (whether arising under statute or common law) caused by the Buyer’s failure to provide appropriate equipment and manual labour for off-loading (whether or not the off-loading is supervised by or on behalf of the Buyer) for: 4.6.2.1 any personal injury to or death of any of the Company’s employees, agents or sub-contractors or any third party; and 4.6.2.2 any damage to or loss of any property of the Company, its employees, agents or sub-contractors or any third party. 4.7 Instalments 4.7.1 The Company may make delivery of the Goods by instalments. 4.7.2 Each separate instalment shall be invoiced and paid for in accordance with the Contract. 4.7.3 Failure by the Company to deliver any one or more (but not all) instalments in accordance with a Contract or any claim by the Buyer in respect of any one or more (but not all) instalments shall not entitle the Buyer to treat that Contract as repudiated. 4.7.4 Failure by the Buyer to pay for any one or more instalments in accordance with a Contract shall entitle the Company (without prejudice to its other rights and remedies): 4.7.4.1 to suspend without further notice deliveries of Goods or goods under any other contract between the Company and the Buyer pending payment by the Buyer; and/or 4.7.4.2 to treat that Contract as repudiated by the Buyer. 4.8 Non-Delivery of the Goods 4.8.1 Irrespective of condition 4.5, the quantity of any consignment of Goods as recorded by the Company upon despatch from the Company’s place of business shall be conclusive evidence of the quantity received by the Buyer on delivery unless the Buyer can provide conclusive evidence proving the 5.6 Where the Services are to be performed or the Goods are to be supplied outside the UK, the Buyer will assist the Company to ascertain the nature and extent of and to comply with laws, regulations, orders or by-laws of any local or national authority having the force of law in the country where the Services are to be performed or the Goods supplied, or which may affect the Company in the performance of its obligations under the Contract. 5.7 Unless otherwise agreed in writing by the Company, any dates specified by the Company for Practical Completion are approximate only and may not be made of the essence by notice. If no dates are so specified, Practical Completion will be within a reasonable time of the Company being provided with suitable access to the Site. 5.8 Subject to the other provisions of these terms and conditions the Company will not be liable for any loss (including loss of profit), costs, damages, charges or expenses caused directly or indirectly by any delay in or failure to achieve the Practical Completion by any date or within any time period set out in the Contract (even if caused by the Company’s negligence). 5.9 Where the Company incurs extra cost during the provision of the Services resulting from suspension of work, the Buyer’s instructions or lack of instructions, the Buyer’s act or omission, the Buyer’s failure or delay to comply with the obligations of condition 5.5 and 5.6, interruptions, delays, overtime, unusual hours, mistakes, or work for which the Company is not responsible, such extra cost as well as the cost incurred by keeping any of the workforce on Site after completion of the Services on Site, shall be added to the Contract price and be for the account of the Buyer and in accordance with the provisions of the Contract. 5.10 Where Services have been provided by the Company the Goods shall be deemed to be accepted by the Buyer at the earlier of: 5.10.1 the Company certifying in writing that erection is complete, or where the Company is required to test the Goods on Site, the Company certifying that the Goods have passed such tests; or 5.10.2 the Buyer taking over the Goods. 6. Force majeure 6.1 The Company shall not be liable to the Buyer in any manner or be deemed to be in breach of a Contract (subject to condition 10) because of any delay in performing or any failure to perform any of the Company’s obligations under this Contract if the delay or failure was due to any cause beyond the Company’s reasonable control. 6.2 Without prejudice to the generality of condition 6.1 the following shall be included as causes beyond the Company’s reasonable control: 6.2.1 governmental actions, war or threat of war, national emergency, riot, civil disturbance, sabotage, terrorism or threat of terrorism or requisition; 6.2.2 Act of God, fire, explosion, flood, epidemic or accident; 6.2.3 import or export regulations or embargoes; 6.2.4 labour disputes not including disputes involving the Company’s work-force; 6.2.5 inability to obtain or delay in obtaining supplies of adequate or suitable material, fuel, parts, machinery or labour; or 6.2.6 any failure or negligence or breach of contract on the part of the Buyer or its sub-contractors, contractors, agents or employees. 7. Risk/Ownership 7.1 Risk or damage to or loss of Goods shall pass to the Buyer upon delivery of the Goods, (unless otherwise agreed in writing by the parties). 7.2 Ownership of the Goods shall not pass to the Buyer until the Company has received in full (in cash or cleared funds) all sums due to it in respect of: 7.2.1 the Goods and Services; and 7.2.2 all other sums which are or which become due to the Company from the Buyer on any account. 7.3 Until ownership of the Goods has passed to the Buyer, the Buyer must: 7.3.1 hold the Goods on a fiduciary basis as the Company’s bailee; 7.3.2 store the Goods (at no cost to the Company) separately from all other goods of the Buyer or any third party in such a way that they remain readily identifiable as the Company’s property; 7.3.3 not destroy, deface or obscure any identifying mark or packaging on or relating to the Goods; 7.3.4 maintain the Goods in satisfactory condition insured on the Company’s behalf for their full price against all risks to the reasonable satisfaction of the Company. On request the Buyer shall produce the policy of insurance to the Company; and 7.3.5 hold the proceeds of the insurance referred to in condition 7.3.4 on trust for the Company and not mix them with any other money, nor pay the proceeds into an overdrawn bank account. 7.4 The Buyer may resell the Goods before ownership has passed to it solely on the following conditions: 7.4.1 any sale shall be effected in the ordinary course of the Buyer’s business at full market value and the Buyer shall account to the Company accordingly; and Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 95 Pre-Filtration, Class G3 to F5 Bag and Compact Filters, Class F5 to F9 5.1 The Services shall be performed in the manner set out in the Specification. 5.2 The Company shall agree with the Buyer the date and the place at which the Goods shall be ready for testing and commissioning as provided for in the Contract. 5.3 Any dates specified by the Company for testing and commissioning as provided for in the Contract are approximate only and may not be made of the essence by notice. 5.4 Company’s Obligations 5.4.1 Subject to the provisions of the Contract, the Company shall with due skill and care design, manufacture and deliver to site, erect, test and commission the Goods, carry out the Services and complete any tests provided for in the Contract. 5.5 Buyer’s Obligations 5.5.1 The Buyer shall provide (or shall procure the provision of) at its own expense and in a timely manner the Company and its employees, agents and sub-contractors with: 5.5.1.1 all necessary access to the Site in reasonable time for the proper performance of the Contract and to include access to such roads or other means of access as may be necessary; 5.5.1.2 all relevant consents, wayleaves, approvals, import licences and permits as are required for the provision of the Services by the Company; 5.5.1.3 all building structures, foundations, approaches or work equipment or materials within the time specified in the Contract and of the quantity specified and in a condition suitable for the efficient transportation, reception, installation and maintenance of the Goods and/or Services; 5.5.1.4 any suitable lifting equipment belonging to the Buyer that may be available on Site to operate for the purposes of the Services; 5.5.1.5 where agreed in the Contract, make available sufficiently skilled persons necessary to perform the Services (including, without limitation, masons, joiners, builders and electricians); 5.5.1.6 such supplies of electricity, water, gas, air and other substances or facilities at the Site for use by the Company that may be specified in the Contract; 5.5.1.7 where the Contract provides for any tests or commissioning on Site, unless otherwise stated in the Contract, such fuel, electricity and other services or materials that may reasonably be requested by the Company to enable such tests or commissioning to be carried out effectively; 5.5.1.8 access to a canteen or restroom (where available); 5.5.1.9 appropriate waste disposal facilities (including, without limitation, a designated waste point on Site); and 5.5.1.10 all assistance as may be reasonably required by the Company as necessary for the proper performance of the Contract. H E PA / U L PA F i l t e r s , C l a s s H10 to U17 2.1 Subject to any variation under condition 2.4, each Contract will be on these terms and conditions to the exclusion of all other terms and conditions (including any terms or conditions which the Buyer purports to apply under any purchase order, confirmation of order or similar document). 2.2 The order for Goods and Services by the Buyer from the Company shall be deemed to be an offer by the Buyer to purchase such Goods and Services subject to these terms and conditions. 2.3 No terms or conditions endorsed upon, delivered with or contained in the Buyer’s Specification, purchase order or similar document will form part of any Contract simply as a result of a reference to such document being referred to in a Contract. 2.4 Any variation to these terms and conditions and any representations about the Goods and Services shall have no effect unless expressly agreed in writing and signed by either the Commercial Manager or a Director of the Company. The Buyer must ensure that the terms of its purchase order and any applicable Specification are complete and accurate. 2.5 Acceptance of delivery of the Goods or commencement of the performance of the Services shall be deemed to be conclusive evidence of the Buyer’s acceptance of these terms and conditions. 2.6 Any quotation is given on the basis that no Contract will come into existence until the Company despatches a written acknowledgement of order to the Buyer. Any quotation is valid for a period of 30 days only from its date provided the Company has not previously withdrawn it. 2.7 No order which the Company has accepted may be cancelled by the Buyer except with the written agreement of the Company in response to a written request of the Buyer and on terms that the Buyer shall indemnify the Company in full against all losses (including loss of profit), costs, damages, charges and expenses suffered or incurred by the Company as a result of such cancellation. 5. Services Carbon and Chemical Filters 2. Formation and incorporation contrary. 4.8.2 Irrespective of condition 4.5, the Company shall not be liable for any non-delivery of Goods (even if caused by the Company’s negligence) unless written notice is given to the Company within 7 days of the date when the Goods would in the ordinary course of events have been delivered. 4.8.3 Any liability of the Company for the Goods for non-delivery shall be limited to replacing the Goods within a reasonable time or at the option of the Company issuing of a credit note against any invoice raised for such Goods. 4.8.4 A signature of qualified acceptance on a carrier’s delivery note shall not be written notice to either the carrier or the Company for the purpose of these terms and conditions. Filter Frames and Housings 1.1 In these terms and conditions the following words have the following meanings: “Business Days” any day other than a Saturday or Sunday or a public or bank holiday In England; “Buyer” the person(s) or company whose order for the Goods is accepted by the Company; “Company” Camfil Limited t/a Camfil Farr with company registration number 01404355 and with registered office at Knowsley Road, Haslingden, Lancashire BB4 4EG; “Contract” any contract between the Company and the Buyer for the sale and purchase of the Goods; “Delivery Point” the place where delivery of the Goods is to take place under condition 4; “Goods” any goods which the Company is to supply to the Buyer (including any of them or any part of them); “Intellectual Property” all intellectual and industrial property rights, including without limitation, patents, rights in Know-How, trade marks, registered designs, models, unregistered design rights, unregistered trade marks and copyright (whether in drawings (including manufacturing drawings), plans, specifications, designs and computer software or otherwise), database rights, topography rights, any rights in any invention, discovery or process, and applications for and rights to apply for any of the foregoing, in each case in the United Kingdom and all other countries in the world; “Operational Parameters” operational conditions under which the Goods will operate safely and effectively as referred to in the quotation; “Practical Completion” the completion of the provision of the agreed Services by the Company; “Services” any design work, assembly, installation, testing, commissioning and maintenance services which the parties have agreed the Company is to supply to the Buyer (including any of them or any part of them); “Site” the site at which the Company is to perform the Services; “Specification” the written specification of technical requirements by the Buyer in relation to the provision of the Goods and/ or Services by the Company. 1.2 The headings in these terms and conditions are for convenience only and shall not affect their interpretation. A i r F i l t e r Te c h n o l o g y 1. Interpretation Camfil Farr Solutions A i r F i l t e r Te c h n o l o g y A i r F i l t e r Te c h n o l o g y Standard terms & conditions for the sale of goods 7.4.2 any such sale shall be a sale of the Company’s property on the Buyer’s own behalf and the Buyer shall deal as principal when making such a sale. 7.5 Where the Company is unable to determine whether any goods are the Goods, the Buyer shall be deemed to have sold all goods of the kind sold by the Company to the Buyer in the order in which they were invoiced to the Buyer. 7.6 The Company shall be entitled to recover payment for the Goods notwithstanding that ownership of any of the Goods has not passed from the Company. 7.7 The Buyer grants the Company, its agents and employees an irrevocable licence at any time to enter any premises where the Goods are or may be stored in order to inspect them, or, where the Buyer’s right to possession has terminated, to recover them. Company’s total liability arising in connection with the performance or contemplated performance of the Contract by reason of any breach of contract or of statutory duty or tort (including but not limited to negligence), or any failure to perform or delay in performing of any obligations by the Company under the Contract shall be limited to the £[Contract Price]; and 10.2.5.2 the Company shall not be liable by way of indemnity or by reason of any breach of contract or of statutory duty, by reason of tort (including but not limited to negligence) for any loss of profit, loss of use, loss of production, loss of contracts, loss of goodwill or for any financial or economic loss or for any indirect or consequential damage whatsoever that may be suffered by the Buyer. 11. Termination 8.1 The price for the Goods and Services shall be the Company’s quoted price referred to in the Company’s quotation which shall be binding upon the Company only if the Buyer accepts the Company’s quotation within 30 days (provided the quotation has not already been withdrawn by the Company) after which time it may be altered by the Company without notice. 8.2 Unless otherwise agreed in writing between the parties, the price for the Goods and Services is exclusive of any: 8.2.1 value added tax or other applicable tax; 8.2.2 transport, packaging, loading, unloading and insurance; 8.2.3 in the case of export, import duties, dues, taxes and other charges; and 8.2.4 cost of obtaining any applicable licences and permits necessary to perform the Contract, which the Buyer shall pay in addition when it is due to pay for the Goods and Services in accordance with the Contract. 8.3 The Company may, by giving notice to the Buyer at any time increase the price of the Goods and Services to reflect any increase in the cost of manufacture or delivery of the Goods or performance of the Services which is due to: 8.3.1 any factor beyond the reasonable control of the Company; this includes without limitation, foreign exchange fluctuation, currency regulation, alteration of duties and taxes; 8.3.2 any change in delivery dates, quantities or specifications for the Goods and Services requested by the Buyer; 8.3.3 any delay caused by any instructions of the Buyer or failure of the Buyer to give the Company adequate information or instructions. Any dispute as to the amount of any increase in price shall be determined by the Company’s auditors whose decision shall be conclusive and binding on the Company and the Buyer. 9. Payment 9.1 The Company may invoice the Buyer for the Goods and Services in accordance with the terms set out in the Company’s quotation. 9.2 Time for payment shall be of the essence. 9.3 Payment of the price for the Goods and Services is due in sterling or such other agreed currency within 10 (ten) Business Days of the date of receipt of the invoice. 9.4 No payment shall be deemed to have been received until the Company has received cleared funds. 9.5 All payments payable to the Company under this Contract shall become due immediately upon termination of this Contract despite any other provision. 9.6 The Buyer shall make all payments due under this Contract without any deduction whether by way of set-off, counterclaim or otherwise unless the Buyer has a valid court order requiring an amount equal to such deduction to be paid by the Company to the Buyer. 9.7 If the Buyer fails to make any payment under this Contract on the due date then (without prejudice to its other rights and remedies): 9.7.1 the Company may charge the Buyer interest (both before and after judgement) on the amount unpaid at the annual rate of 4% above the base rate of SEB, Cannon Street, London, from time to time until payment is made in full (a part of a month being treated as a full month for the purpose of calculating interest); and 9.7.2 the Company shall be entitled to suspend performance of any of its obligations under the Contract until the outstanding amount has been received by the Company from the Buyer. 10. Quality 10.1 Warranty 10.1.1 The Company warrants that (subject to the other provisions of these terms and conditions) upon delivery the Goods will, and for a period of 12 (twelve) months from the date of delivery, be of satisfactory quality within the meaning of the Sale of Goods Act 1994. 10.1.2 The Company will, free of charge, within a period of 12 (twelve) months from the date of delivery (or deemed delivery under condition 4.4) repair or, at the option of the Company replace Goods (or the relevant part of the Goods) which are proved to the reasonable satisfaction of the Company to have been at the time of delivery (a) damaged or defective; or (b) not complying with the Specification due to defects in material, or workmanship or design (other than a design made, furnished or specified by the Buyer). This obligation will not apply where: 10.1.2.1 the Buyer has failed to notify the Company of any defect or suspected defect within 14 days of the delivery where the defect should be apparent on reasonable inspection, or within 14 days of the same coming to the knowledge of the Buyer (where the defect is not one which should be apparent on reasonable inspection) and in any event no later than 12 (twelve) months from the date of delivery; or 10.1.2.2 the Buyer has failed to give the Company a reasonable opportunity of examining such Goods after receiving the notice of any defect or suspected defect; or 10.1.2.3 the defect arises because the Buyer (or the Buyer’s customer) failed to follow the Company’s oral or written instructions as to the storage, installation, testing and commissioning (if applicable), use, Operational Parameters or maintenance of the Goods or (if there are none) good trade practice; or 10.1.2.4 the Buyer (or the Buyer’s customer) alters or repairs such Goods or without the written consent of the Company; or 10.1.2.5 the defect in such Goods arises from any defect in any drawing, design, Specification or instruction supplied or approved by the Buyer. Any Goods replaced will belong to the Company and any repaired Goods or replacement Goods will be guaranteed on these terms and conditions for the unexpired portion of the 12 (twelve) month period from the original date of delivery of the replaced Goods. 10.1.3 Any Goods repaired or replaced by the Company pursuant to this condition 10 will be supplied to these terms and conditions. 10.1.4 If the Company complies with condition 10.1.2 it shall have no further liability for a breach of warranty in condition 10.1.5 in respect of the quality of such Goods. 10.2 Indemnity and Limitation of liability 10.2.1 The Buyer shall indemnify the Company against all liability, actions, proceedings, costs, claims, damages or demands in any way connected with this Contract brought or threatened to be brought against the Company by any third party except to the extent the Company is liable to the Buyer in accordance with these terms and conditions. 10.2.2 Subject to condition 10.1.1 and to the maximum extent permissible in law, all conditions and warranties which are implied by statute or otherwise by general law into any Contract or relating to the Goods or the Services are hereby excluded. 10.2.3 The Company does not, unless otherwise expressly provided in the Contract, warrant that the Services or the Goods as described or provided or the incorporation thereof within some larger project will satisfy the Buyer’s requirements. 10.2.4 The Company will accept unlimited liability for: 10.2.4.1 death or personal injury caused by the negligence of the Company; and 10.2.4.2 any breach of its obligations implied by Section 12 of the Sale of Goods Act 1979 or Section 2 of the Supply of Goods and Services Act 1982; and 10.2.4.3 fraudulent misrepresentation. THE BUYERS ATTENTION IS IN PARTICULAR DRAWN TO THE PROVISION OF CONDITION 10.2.5 10.2.5 Subject to conditions 10.2.2, 10.2.3 and 10.2.4: 10.2.5.1 except in the case of any liability on the part of the Company referred to in condition 10.2.4, the 11.1 Each Contract will terminate immediately upon the happening of any one or more of the following events; the Buyer has a bankruptcy order made against him or makes an arrangement or composition with his creditors or otherwise takes the benefit of any Act for the time being in force for the relief of insolvent debtors, or (being a body corporate) convenes a meeting of creditors (whether formal or informal) or enters into liquidation (whether voluntary or compulsory) except a solvent voluntary liquidation for the purpose only of reconstruction or amalgamation, or has a receiver, manager, administrator or administrative receiver appointed of its undertaking or any part thereof, or a resolution is passed or a petition presented to any court for the winding-up of the Buyer or for the granting of an administration order in respect of the Buyer or any proceedings are commenced relating to the insolvency or possible insolvency of the Buyer. 11.2 Each Contract will terminate immediately upon service of written notice of termination by the Company on the Buyer on the happening of any one or more of the following; the Buyer suffers or allows any execution whether legal or equitable to be levied on his/its property or obtained against him/it, or fails to observe or perform any of his/its obligations or duties under the Contract or any other contract between the Company and the Buyer or is unable to pay its debts within the meaning of section 123 of the Insolvency Act 1986 or the Buyer ceases to trade. 11.3 The Company’s rights contained in condition 6, 7,9 and 10 (but not the Buyer’s rights) shall continue beyond the discharge of the Buyer’s and the Company’s primary obligations under the Contract consequent upon its termination. 11.4 The termination of the Contract howsoever arising shall be without prejudice to the rights and duties of either the Buyer or the Company accrued prior to termination. 12. Communication 12.1 All communications between the parties about any Contract must be in writing and delivered by hand or sent by pre-paid first class post or sent by facsimile transmission or electronic mail:12.1.1 (in case of communications to the Company) to its registered office or such changed address as shall be notified to the Buyer by the Company; or 12.1.2 (in the case of the communications to the Buyer) to the registered office of the addressee (if it is a company) or (in any other case) to any address of the Buyer set out in any document which forms part of the Contract or such other address as shall be notified to the Company by the Buyer. 12.2 Communications shall be deemed to have been received: 12.2.1 if sent by pre-paid first class post, 2 Business Days after posting (exclusive of the day of posting); 12.2.2 if delivered by hand, on the day of delivery; 12.2.3 if sent by facsimile transmission or electronic mail on a working day prior to 4:00pm, at the time of transmission and otherwise on the next working day. 12.3 Communications addressed to the Company shall be marked for the attention of the Commercial Manager or a Director of the Company. 13. Intellectual property rights 13.1 Where the Goods or any part of them are manufactured or any process is to be applied to the Goods by or on behalf of the Company to the Specification then the Buyer shall indemnify the Company against all liability, actions, proceedings, costs, claims, damages or demands in any way connected with the Contract brought or threatened to be brought against the Company by any third party as a result of the infringement or alleged infringement of any third party’s Intellectual Property Rights. If any such claim is brought or threatened against the Company then the Company shall be entitled to suspend deliveries of the Goods and/or performance of the Services. 13.2 All information of any kind (including without limitation drawings, specifications, plans, descriptions, blue prints, designs, documents and technical information) supplied by the Company to the Buyer is supplied on the strict understanding that the Intellectual Property Rights therein and in the Goods and the Services are vested in and shall remain the sole property of the Company. If the Buyer shall in any way acquire such rights then the Buyer shall immediately inform the Company and shall take such steps immediately as may be required by the Company to assign such rights or vest title in such rights in the Company. 14. General 14.1 Time for performance of all obligations of the Buyer is of the essence. 14.2 Each right or remedy of the Company under the Contract is without prejudice to any other right or remedy of the Company whether under the Contract or not. 14.3 Any provision of the Contract which is held by any competent authority to be invalid, void, voidable, unenforceable or unreasonable (in whole or in part) shall to the extent of such invalidity, voidness, voidability, unenforceability or unreasonableness be deemed severable and the other provisions of the Contract and the remainder of such provision shall not be affected. 14.4 Failure by the Company to enforce or partially enforce any provision of the Contract will not be construed as a waiver of any of its rights under the Contract. 14.5 The Company may assign, license or sub-contract all or any part of its rights or obligations under the Contract without the Buyer’s consent. 14.6 The Contract is personal to the Buyer who may not assign, license or sub-contract all or any of its rights or obligations under the Contract without the Company’s prior written consent. 14.7 The Company and the Buyer do not intend that any of the terms of the Contract will be enforceable by virtue of the Contracts (Rights of Third Parties) Act 1999 by any person not a party to it. 14.8 The formation, construction, performance, validity and all aspects of the Contract are governed by English law and the parties submit to the non-exclusive jurisdiction of the English Courts. Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 96 As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. 8. Price Carbon and Chemical Filters H E PA / U L PA F i l t e r s , C l a s s H10 to U17 Bag and Compact Filters, Class F5 to F9 Pre-Filtration, Class G3 to F5 Camfil Farr Solutions Notes Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736 www.camfilfarr.co.uk 97 A i r F i l t e r Te c h n o l o g y Filter Frames and Housings As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice. A i r F i l t e r Te c h n o l o g y Head Office : Regional Centres : MANCHESTER LONDON Head Office & Manufacturing Plant Camfil Limited Knowsley Road Haslingden Lancashire BB4 4EG Tel: +44 (0) 1706 238000 Fax: +44 (0) 1706 226736 MIDLANDS SCOTLAND Industry Segment Specialists : AIR HYGIENE Viv Turner AUTOMOTIVE Mark Taylor COMFORT SEGMENT Glasgow David Moulton CONSULTANTS & SPECIFIERS Peter Dyment CONTAINMENT SYSTEMS Mike Vinson DUST CONTROL Manchester John Purvis/Matthew Brown Birmingham FOOD INDUSTRY Tim Pagett GAS TURBINE Martin Stenton London HOSPITALS Dave Rimmer MOLECULAR FILTRATION Chris Ecob PHARMACEUTICAL Neil Orrill www.camfilfarr.co.uk VEHICLE REFINISHING Gary Warrington On world standards... ...Camfil Farr is the leader in clean air technology and air filter production. Camfil Farr has its own product development, R&D and world wide local representation. Our overall quality goal is to develop, produce and market products and services of such a quality that we aim to exceed our customers expectations. We see our activities and products as an expression of our quality. To reach a level of total quality it is necessary to establish an internal work environment where all Camfil Farr employees can succeed together. This means an environment characterised by openness, confidence and good business understanding. www.camfilfarr.co.uk Camfil Limited Knowsley Road Haslingden Lancashire BB4 4EG Tel: +44 (0) 1 706 238000 Fax: +44 (0) 1 706 226736 E-mail: sales@camfil.co.uk