farm grain bin construction manual
Transcription
farm grain bin construction manual
CONSTRUCTION MANUAL 12'- 54' [3 658 - 16 459 mm] Dia. FARM GRAIN BIN (2.67'' Narrow Corrugation) September 2008 MGB1945B Warranty BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Warranty Brock Grain Systems (“BROCK”) warrants each new BROCK® Farm Grain Bin manufactured by it to be free from defects in material or workmanship for five (5) years from and after the date of initial installation by or for the original purchaser. If such a defect is found by the Manufacturer to exist within the one-year period, the Manufacturer will, at its option, (a) repair or replace such product free of charge, F.O.B. the factory of manufacture, or (b) refund to the original purchaser the original purchase price, in lieu of such repair or replacement. Labor costs associated with the replacement or repair of the product are not covered by the Manufacturer. CONDITIONS AND LIMITATIONS 1. The product must be installed by and operated in accordance with the instructions published by the Manufacturer or Warranty will be void. 2. Warranty is void if all components of the system are not original equipment supplied by the Manufacturer. 3. This product must be purchased from and installed by an authorized dealer or certified representative thereof or the Warranty will be void. 4. BROCK® bins and augers are designed for grains and/or free-flowing materials and are not warranted for other distribution or substances unless approved unloading equipment is used. Call Brock Grain Systems for approved unloading equipment. Other use will void warranty. 5. This Warranty applies only to systems for the care of grain and feed. Other applications in industry or commerce are not covered by this Warranty. 6. Malfunctions or damage resulting from misuse, abuse, negligence, alteration, accident, or lack of proper maintenance shall not be considered defects under the Warranty. The Manufacturer shall not be liable for any consequential or special damage which any purchaser may suffer or claim to suffer as a result of any defect in the product. “Consequential” or “special damages” as used herein include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders, lost income, increased overhead, labor and incidental costs and operational inefficiencies. THIS WARRANTY CONSTITUTES THE MANUFACTURER’S ENTIRE AND SOLE WARRANTY AND THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES, INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO MERCHANTIBILITY, FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR QUALITY OF THE PRODUCT FURNISHED HEREUNDER. BROCK dealers are not authorized to modify or extend the terms and conditions of this Warranty in any manner or to offer or grant any other warranties for BROCK products in addition to those terms expressly stated above. An officer of CTB, Inc. must authorize any exceptions to this Warranty in writing. The Manufacturer reserves the right to change models and specifications at any time without notice or obligation to improve previous models. Effective September 2008 BROCK GRAIN SYSTEMS A Division of CTB Inc. P.O. Box 2000 · Milford, Indiana 46542-2000 · U.S.A. Phone (574) 658-4191 · Fax (574) 658-4133 e-mail: brock@brockmfg.com · Internet: http://www.brockmfg.com NOTE: The original, authoritative version of this Manual is the [English] version produced by CTB, Inc. or any of its subsidiaries or divisions, (hereafter collectively referred to as "CTB"). Subsequent changes to any Manual made by any third party have not been reviewed nor authenticated by CTB. Such changes may include, but are not limited to, translation into languages other than [English], and additions to or deletions from the original content. CTB disclaims responsibility for any and all damages, injuries, Warranty claims and/or any other claims associated with such changes, inasmuch as such changes result in content that is different from the authoritative CTB-published [English] version of the Manual. For current product installation and operation information, please contact the Customer Service and/or Technical Service Departments of the appropriate CTB subsidiary or division. Should you observe any questionable content in any Manual, please notify CTB immediately in writing to: CTB Legal Department, P.O. Box 2000, Milford, IN 46542-2000 USA. Thank You The employees of BROCK GRAIN SYSTEMS would like to thank you for your recent BROCK purchase. If a problem should arise, your BROCK dealer can supply the necessary information to help you. 2 MGB1945B Contents Topic Page User Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Remember! Think SAFETY First! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Support Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Distributor and Installer Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 About This Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Identification of Parts and Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Recognize SAFETY Information / Understand Signal Words . . . . . . . . . . . . . . . . . . . . . . . . 6 Follow SAFETY Instructions / SAFETY Decals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 DANGER of Suffocation / SAFETY Near Moving Equipment . . . . . . . . . . . . . . . . . . . . . . . 7 Electrical SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Plan Safe Routes for Power, Augers and Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 There are Suffocation Hazards in Flowing Grain! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 SAFETY Hazards and Recommendations / Possible Corrective Measures . . . . . . . . . . . . . 10 DANGER, WARNING and CAUTION Decals and Their Placement . . . . . . . . . . . . . . . . . 13 Considerations that may result in a hazard, damage your Grain Bin and/or void your Warranty . . . . 14 Planning Before Your Grain Bin Arrives. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Choose The Grain Bin Site / Check Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Body Sheet Identification / Tools and Equipment Needed. . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Adequate Roof Support / Adequate Tank Support During Construction . . . . . . . . . . . . . . . . 16 Placement of Components / Component Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Foundation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Foundation Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Foundation Diagram: 4 - 8 Rings (English Measurements) . . . . . . . . . . . . . . . . . . . . . . . . 18 Foundation Diagram: 9 - 12 Rings (English Measurements) . . . . . . . . . . . . . . . . . . . . . . . 18 Foundation Information in English Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Foundation Diagram: 4 - 8 Rings (Metric Measurements) . . . . . . . . . . . . . . . . . . . . . . . . . 20 Foundation Diagram: 9 - 12 Rings (Metric Measurements) . . . . . . . . . . . . . . . . . . . . . . . . 20 Foundation Information in Metric Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Locate Anchor Bolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Anchor Bolt Information: Farm Grain Bins with TWO and THREE Anchors per Body Sheet . . . . . 23 Alternate Foundations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Construction Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Construction begins with the Top Ring of the Tank / Build the Roof on the Top Ring . . . . 26 Lift the Roof and Top Ring to continue construction of the Tank Walls . . . . . . . . . . . . . . . 26 Set, seal and ground the Tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Choosing Proper Jacks to Lift the Grain Bin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Safety Procedures During Jacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Grain Bin Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Body Sheet Identification / Caulking Body Sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Assemble the Top Ring First . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Build your Roof according to your Roof Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Adding Body Sheet Rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Exterior Sidewall Stiffener Assembly Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Anchoring Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 Grain Bin Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Body Sheet Layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-39 Recirculating Grain Bin Gauge Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Heavy Body Sheet Gauge Schedule (7- and 8-Ring Grain Bins) . . . . . . . . . . . . . . . . . . . . . . . . . 40 Farm Grain Bin Body Sheet Part Number Charts . . . . . . . . . . . . . . . . . . . . . . . . . 41-42 Parts Listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 MGB1945B 3 General BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Parts Listing41 General Remember! Think SAFETY First! This symbol is used throughout this Manual to identify particular stages where the Grain Bin Contractor and/or Operator need to take special note and precautions regarding the danger described in these Instructions. Please read all the SAFETY information and the instructions completely prior to beginning the construction. Support Information BROCK® products are designed for grains and/or free flowing materials. Using this equipment for any other purpose or in a way not within the operating recommendations specified in this Manual will void the Warranty and may cause injury or death. This Manual is designed to provide comprehensive planning and construction information for this BROCK® product. The Table of Contents provides a convenient overview of the information in this Manual. Dealers: Please provide the Customer with the information to complete the easy reference below. Dealer or Customer: Complete the following information about your BROCK® product. Store this Manual in a safe, dry place for future reference. Distributor and Installer Information Please fill in the following information about your Product. Keep this Manual in a clean, dry place for future reference. Distributor’s Name ___________________________________________________ Distributor’s Address ________________________________________________ Distributor’s Phone _______________________ Date of Purchase ___________ Installer’s Name _____________________________________________________ Installer’s Address ___________________________________________________ Installer’s Phone _______________________ Date of Installation ___________ System Specifications ________________________________________________ ___________________________________________________________________ 4 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) About This Manual About This Manual The intent of this Manual is to help you in two ways. One is to follow step-by-step in the order of assembly of your Grain Bin. The other way is for easy reference if you have questions in a particular area. IMPORTANT: Read this Base Construction Manual and ALL Supplemental Manuals carefully before starting construction. The Supplemental Roof Manual is MGB1496 for the 12' - 48' [3 658 - 14 630] Farm Roof, and MCB1484 for the 48' - 54' [14 630 - 16 459] Commercial Roof. IMPORTANT: Pay particular attention to all SAFETY information on Pages 7-14. • Metric measurements are shown in millimeters and in parentheses following the English measurement, unless otherwise specified. " equals inches and ' equals feet in English measurements. Example: 15' [4 572] 24' [7 315] • “Horizontal” (—) and “Vertical” (l), Bottom and Top, in the instructions refer to the Grain Bin as it is standing. • “Left” and “right” refer to the Grain Bin as you are looking at it from the outside. • Optional equipment contains necessary instructions for assembly or operation. • Major changes from the last printing will be listed on the back cover. • This Planning Symbol is used in areas where planning needs to take place before construction continues. Identification of Parts and Hardware IMPORTANT: No Hardware substitutions are permitted unless noted. Diagrams are provided throughout this Manual to identify Parts and Hardware used in that application. All body and Roof seams use 5/16 x 1" Grade 8.2 Hex Head Bin Seal Bolts and Hex Nuts, or the optional Plastic Head Bolts, with the heads on the outside of the Grain Bin. Grade 8.2 Hex Head Bolts are identified with markings such as in Figure 1. • • • • • Parts and basic components are identified in Figures and their accompanying Tables as “Items” with a black number in white circle. Hardware (and hardware connections between Parts) are identified with a white number in a shaded circle. See Figure 1. Hardware Item numbers are listed after the Parts in the Figure Table. Dimensions and lengths are noted with a white circle on an arrow or line, then identified with numeric values in the Figure Table. Specific holes, positions, or locations mentioned in the text are noted in the Figure with an asterisk. Very small numbers near an illustration (I.e., 1257-48) are identification of the graphic, not a Part Number. PARTS.WMF Hex Head Bolt Plastic Head Bolt COMPONENT Truss Head Bolt Grade 8.2 Markings 2 17 Figure 1. Hardware Identification MGB1945B Hex Nut Flange Nut HARDWARE or HARDWARE/COMPONENT connection PARTS.WMF 5 SAFETY BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) SAFETY Recognize SAFETY Information This is the Safety-Alert Symbol. When you see this symbol on your equipment or in this Manual, be alert to the potential for personal injury. Signal words DANGER, WARNING, or CAUTION, are used with the Safety-Alert Symbol. Understand Signal Words DANGER indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. WARNING indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury. CAUTION indicates a hazardous situation which, if not avoided, MAY result in minor or moderate injury. Follow SAFETY Instructions Carefully read all SAFETY messages in this Manual and on your equipment Safety Signs. Follow recommended precautions and safe operating practices. Keep SAFETY Signs in good condition. Replace missing or damaged SAFETY Signs. DANGER! Grain Bin installations shall meet the National Fire Protection Association Standard 61B for the prevention of fires and explosions in grain elevators and facilities handling bulk raw agricultural commodities. SAFETY Decals SAFETY information has been provided by the Manufacturer to help insure the safe and proper use of this product. This SAFETY information has been placed on components throughout the structure to provide proper access to the user. The following Decals in Figures 2, 6, 7, and 8 are located on equipment as shown in the Manual drawings on Page 16. If the SAFETY Decals are not properly placed or if they are in any way damaged or altered, call the Manufacturer for immediate replacement. IMPORTANT! 6 Check all equipment for DANGER, WARNING and CAUTION Decals and their proper placement, BEFORE equipment is operated. NEVER use equipment if Decals are missing, improperly placed, damaged, or altered. MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) SAFETY SAFETY DANGER of Suffocation/SAFETY Near Moving Equipment The DANGER Decal (13-26114) in Figure 2 is located both on the inside and outside of the Door Cover and on the inside and outside of the Manhole Cover. It appears in Spanish next to the English Decal. A French language Decal is also available. Other languages may be available upon request. La calcomanía de ADVERTENCIA (13-26114SP) en la Figura 2 está ubicada cubiertas interior y exterior de la puerta y en las caras interior y exterior de la escotilla. La calcomanía de ADVERTENCIA aparece en español al lado de la calcomanía de inglés. La calcomanía de ADVERTENCIA tanbién está disponible en la idoma francés. Otras idiomas sería disponible al solicitarla. L’autocollant DANGER (13-26114FR) sur le dessin 2 est situé sur l’intérieur et l’extérieur de la trappe de fermeture ainsi que sur l’intérieur et l’extérieur de la poignée. L’autocollant DANGER apparait en espagnol à coté de l’autocollant anglais. Un autocollant en français est également disponible. D’autres traductions seront disponsibles selon la demande. Figure 2. DANGER Decal (13-26114) MGB1945B 7 SAFETY BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) SAFETY Electrical SAFETY Important consideration should be given to some or all of the following devices and to others which may be appropriate: 1. Overload protection devices such as shear pins, torque limiters, zero speed switches, etc., to shut off and lock out power whenever operation of equipment is stopped as a result of excessive material, foreign objects, excessively large lumps, etc. 2. Safety shut-off switch with power lockout provisions at auger drive 3. Emergency stop switches readily accessible wherever required 4. Electrical interlocking to shut down the feeding auger whenever a receiving auger stops 5. Signal devices to warn personnel of possible startup of auger, especially if started from another location 6. Special enclosures for motors and controls for hazardous atmospheric conditions. In selecting electrical control equipment to be used with any installation, the purchaser must use equipment conforming to the National Electrical Code, the National Electrical Safety Code and other local or national codes. Figure 3. Electrical WARNING Decal Plan Safe Routes for Power, Augers and Doors Coordinate with your local utilities for the most effective and safe route(s) of construction and placement of your Grain Bin system with available power. This is critical for overall safety, and could save costly corrections later. See Figure 4. Item 1 2 3 4 5 6 Description 100' [3 480] Minimum Clearance 3' [914] Minimum Clearance No Overhead Conductors Storage Structure(s) geometry optional Overhead Conductor and Pole Underground Conductor Figure 4. Minimum Conductor Clearances for Conveyors and Storage Structures 8 1 1 TOP VIEW 1 1 4 5 6 1 1 3 Plan 3 1 FRONT ELEVATION 1 5 2 6 4 conduit.pcx 10/95 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) SAFETY SAFETY DANGER! There are Suffocation Hazards in Flowing Grain! Never enter a Grain Bin of flowing feed, grain, or other material. Failure to follow these instructions will result in death or serious injury. From the time the auger starts, you have 2-3 seconds to react. In 4-5 seconds, you are trapped. After 22 seconds, you are completely covered. Figure 5. Suffocation Hazards in Flowing Grain MGB1945B 9 SAFETY BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) SAFETY Safety Hazards and Recommendations 1. Never enter a Grain Bin of flowing grain. 2. Never enter a Grain Bin when unloading equipment is running, whether or not grain is flowing. 3. Never enter a Grain Bin that has automatic unloading equipment without locking out the control circuit. 4. Never enter a Grain Bin that you do not know the nature of previous grain removal, especially if there is any crusting evident. 5. Always be cautious before walking on any surface crust. 6. It is always advisable to have three people involved, two on the outside and one inside, when entering a questionable Grain Bin/storage circumstance. The person in the Grain Bin should be secured or fastened to a safety rope with the two persons outside capable of lifting that person out without entering the Grain Bin. One person outside cannot do this, and cannot go for help and maintain preliminary aid. 7. Never work in obviously dusty-moldy grain without a respirator. Never work in such conditions, no matter what the protection, without a second person on safety standby. Use a respirator capable of filtering fine dust. 8. Be aware that your tolerance to a given material may be limited, and that you should not deliberately and knowingly expose yourself on the idea that “it won’t hurt me.” Later in life, you may have used up all of your tolerance. 9. Always be cautious when you are working with grain that is not in good condition. You can have molds, blocked flow, cavities, cave offs, crusting–it is time to be alert. 10. Never depend on a second person, either on the Grain Bin roof, on the ground, or any other remote point to whom you shout instructions to start or stop equipment. a.Equipment noise can block out commands or cries for help. b.The second person may fall or over-exert in the panic and haste of getting off the Grain Bin or running to the control point. Possible Corrective Measures 1. Install Ladders inside all Grain Bins. 2. If you must enter a Grain Bin with evident danger, use a rope and safety harness to support and lift you in the event of trouble. Before it is too late . . . Talk to your children, your co-workers, and your neighbors about the above safety information. Their lives, your life, may depend on it. 10 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) SAFETY SAFETY The WARNING Decal in Figure 7 is located on the outside of the Door Cover. Figure 7. Grain Bin WARNING Decal 19-44069 MGB1945B 11 SAFETY BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) SAFETY The CAUTION Decal in Figure 8 is located on the outside of the Door Cover. Figure 8. Grain Bin CAUTION Decal 19-44067 12 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) SAFETY SAFETY DANGER, WARNING and CAUTION Decals and Their Placement SAFETY information has been provided by the Manufacturer to help insure the safe and proper use of this product. This SAFETY information has been placed on components throughout the structure to provide proper access to the user. The following Decals are located on equipment as shown. If DANGER, WARNING and CAUTION Decals are not properly placed or if they are in any way damaged or altered, call the Manufacturer for immediate replacement. IMPORTANT! Check all equipment for WARNING, DANGER and CAUTION Decals and their proper placement, BEFORE equipment is operated. NEVER use equipment if Decals are missing, improperly placed, damaged or altered. DANGER Decal (13-26114) Located on both the Inside and Outside Cover of the Door and on the inside and outside of the Manhole Cover. It should read exactly as Figure 2 on Page 7. 1 DANGER Decal (Spanish) (13-26114SP) Located on both the Inside and Outside Cover of the Door and on the inside and outside of the Manhole Cover. 2 La calcomanía de ADVERTENCIA (13-26114SP) está ubicada cubiertas interior y exterior de la puerta y en las caras interior y exterior de la escotilla. La calcomanía de ADVERTENCIA aparece en español al lado de la calcomanía de inglés. La calcomanía de ADVERTENCIA tanbién está disponible en la idoma francés. Otras idiomas sería disponible al solicitarla. 1 2 3 WARNING Decal (19-44069) Located on the Outside Cover of the Door. It should read exactly as Figure 7 on Page 11. 4 CAUTION Decal (19-44067) Located on the Outside Cover of the Door. It should read exactly as Figure 8 on Page 12. 1 2 3 4 Figure 9. Decal Placement MGB1945B 13 SAFETY BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) SAFETY Considerations that may result in a hazard, damage your Grain Bin and/or void your Warranty BROCK® Grain Bins are offered in several models for specific uses. In order to maintain your Grain Bin and its Warranty, the appropriate type Grain Bin must be used. Consult BROCK Grain Systems/CTB Grain Systems or your BROCK® Dealer. Read and understand the Owner/Operators Manual and all SAFETY Decals. Grain Bin damage can occur due to improper construction of the Grain Bin: 1. Use all hardware specified in the instructions and make no substitutions. 2. Refer to the Foundation Manual for proper Foundation specifications. Radial cracks in the Foundation are a danger signal. The Foundation is growing outwardly, and is also pulling the Grain Bin with it. These forces can be large enough to cause Bolt damage in the vertical seams of the bin wall. It is suggested that if cracks are present they be monitored for any changes, and remedial action taken. 3. Stiffened Grain Bins must be leveled so a vertical dimension between adjacent Stiffeners does not exceed 1/8" [3.2]. If Stiffeners are not level, Bolts attaching the Stiffener to the Body Sheet—as well as the vertical and horizontal seam Bolts—may become overstressed and shear, causing total failure. 4. If the Grain Bin has a perforated Floor on columns/Floor Supports, and those columns fail due to improper installation, the Grain Bin can shift sideways, causing both sidewall and roof damage. CAUTION! Cables to support conveying equipment such as bucket elevators or conveyor legs must not be attached to the Grain Bin roof or sidewalls. To do so would cause damage to the Grain Bin. Refer to your Roof Manual for construction of proper supports for such equipment. WARNING! Additional loads on Grain Bin sidewalls, roofs and floors can be created by improper drying methods. Grain Bin damage can also occur due to improper ventilation, loading and unloading of the Grain Bin: 1. When the Grain Bin is filled off-center; 2. When unloading is done from the Door or an off-center floor port, uneven wall pressures may occur, allowing the wall to flatten directly nearest the unloading point; damage can be seen above and several feet to either side of this area. In stiffened Grain Bins this failure may be seen in wall sheets nearest the unloading point. Severe Sheet seam and Stiffener damage can occur, causing complete Grain Bin damage. Internal grain pressures change when only a few bushels of grain have been removed. Grain Bin damage can be caused by incorrectly unloading even small amounts of grain. 14 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Planning Before Your Grain Bin Arrives Planning Before Your Grain Bin Arrives Choose the Grain Bin Site For soil and foundation specifications, refer to Pages 18-21 in this Manual. Select the site of your Grain Bin with care. Planning for future expansion is of prime consideration. The soil area for your Grain Bin(s) should be firm and well drained with a uniform bearing capacity of at least 3000 pounds per square foot [14 647 kg/m ]. 2 Foundations shall be appropriately designed for local soil and frost depth conditions. Check Delivery Your Grain Bin is made up of many parts and checked carefully at the time of shipment. However, use the packing slip and check your shipment on arrival to be sure it is complete. IMPORTANT! How to control “Wet Storage Stain” (RUST!) on galvanized Body Sheets: Do not permit moisture from weather, condensation, or other sources to remain between Body Sheets. If moisture is present, separate the Sheets IMMEDIATELY for good air circulation. Where possible, store all Bin components in a warm, dry place away from contaminants such as fertilizer, chemicals and road salt. If this is not done, white/red rust will appear. The paper cover on the BROCK® Decal helps prevent damage to the Decal during Grain Bin construction. However, it may be difficult to remove if left in direct sunlight for several hours. The BROCK® Decal is to be applied in the center of a Body Sheet in the first Ring down from the top. Body Sheet Identification Each Body Sheet is identified by Part Number, gauge and diameter. For further information, see the BODY SHEET PART NUMBER Listing and Layout Diagrams in this Manual, Pages 36-39. Tools and Equipment Needed • • • • • • • • • • • MGB1945B 7/16" - 1'' Box End Wrenches Adjustable Wrenches up to 1-1/2'' [38] for adjustable expanders 12'' [305] Long Drift Punches Hammer Screwdriver Speed Wrench and Sockets Impact Wrench and Sockets Lifting Jacks Lifting Brackets Protective gloves, eyewear, earplugs, and steel-toed shoes Nail aprons to hold a supply of Bolts and Nuts during assembly 15 Planning Before Your Grain Bin Arrives BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Adequate Roof Support The Approximate Working Height* Chart in your Roof Construction Manual will be essential in planning the support of the Roof and/or Sub-Structure either by crane or center support. Be sure your lifting equipment is adequate for the height and weight of your particular Roof. Adequate Tank Support During Construction Read and follow the information on Jacking on Pages 30-34 of this Manual. IMPORTANT! The number of lifting jacks and brackets required is determined by factors such as Grain Bin size, soil compaction, wind velocity, design of jacks, etc. Read and follow the information on Jacks on Pages 28-29. A 5/16'' Grade 8.2 Bin Seal Bolt has an approximate safe load of 1,840 pounds [835 kg]. keep this in mind for the number of Bolts you use to lift Grain Bins during assembly. A 3/8'' Grade 8.2 Bin Seal Bolt has an approximate safe load of 2,650 pounds [1 202 kg]. keep this in mind for the number of Bolts you use to lift Grain Bins during assembly. Tighten 5/16'' Nuts to 15-20 ft-lb of torque. Tighten 3/8'' Nuts to 25-30 ft-lb of torque. Placement of Components Make a sketch and plan component placement of such things as: • Roof Stairs • Manhole Panel • Unloading Equipment • Roof Vents • Inside and Outside Ladders and Platforms • Guardrail access point • Doors • Filling Equipment • Fans • Side Discharge (outlet cannot be at a vertical seam) Component Planning 4 1 3 1 4 2 Figure 10. Outside Ladder 2 Figure 11. Outside Ladder with Platform Item Description 1 Outside Ladder 2 2-Ring Door 3 Manhole Platform 4 Inside Ladder 16 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Foundation Foundation Foundation Layout 1.Drive a small pipe in the ground to mark the center of the Foundation. 2.The top of your pipe should be the height of your finished Foundation. See Pages 18 through 21 for more specific information. 3.With the pipe for a pivot point, use a board or measured chain with a sharp stake attached to the outer end to mark the correct diameter of your Foundation. 3 1 4 1257-23B 11/98 2 Figure 10. Transition Foundation Item 1 2 3 4 MGB1945B HIGH and LOW TRANSITION AERATION TRANSITION 44 1/16" [1 119] 44 1/16" [1 119] 65" [1 651] 47 7/16" [1 205] Transition Duct Distance is determined by the type of fan and heater system used. 17 Foundation BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Foundation Diagram: 4 - 8 Rings (English Measurements) 4 20 9 26 23A 24 3 1 2 8 16 11 5 6 Figure 11. 4-8 Ring Foundation Diagram in ENGLISH Measurements 12 25 Description Item Description Anchor Bolt 1/2 x 8'' x 2'' 13 Bottom Radial: #14 @ 12'' 14 #4 @ 12'' ea. face, ea. way 1 with 6 1/2'' embedment (See NOTE in 15 # 4 stirrups @12'' Instructions, facing Page 16 Top Ring: 2 - #4 1/2'' x 6'' Premolded 2 Continuous Expansion 17 Bottom Ring: 3 - #4 Joint Filler 18 Middle Rings: 4 @ 12'' max. 19 Top Radial* 6'' x 6'' W1.4 x W1.4 3 Wire Welded Fabric* 20 Outside Wall Diameter* 4 1 1/2'' Projection 21 Footer Width* 5 Vapor Barrier 22 Footer Depth 12'' 6 6'' Base Material 23A Slab Depth 4'' thickness 7 3'' Clearance 23B Slab Depth 6'' thickness 8 2'' Clearance 24 Anchor Bolt Circle Radius See Page 21. 9 15'' Wall Width 10 12'' 25 Wall Height 42'' 6'' (may vary from 2''11 24'') not be less than 4'' on 26 Must any Anchor Bolt Wall height, 36'' min. 12 below grade * See chart column, facing Page 18 Item 7 8 15 17 Foundation Diagram: 9 - 12 Rings (English Measurements) 20 4 11 8 2 9 23B 24 1 3 25 26 14 8 12 6 5 16 19 22B 10 7 21 18 8 Figure 12. 9-12 Ring Foundation Diagram in ENGLISH Measurements 13 17 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Foundation Foundation Information in English Measurements • • • • • • • • • • • • • Concrete in footings shall have a minimum compressive strength, f’c = 3000 psi at 28 days. Concrete reinforcing steel shall have a minimum yield strength of 33,000 psi. Foundations shall be appropriately designed for local soil and frost depth conditions. Sizes given are adequate for resisting 1.5 times the overturning due to a 90 mph wind acting on 0.6 times area of Grain Bin. Foundations shall be placed on soil of bearing capacity of 3000 psf or special modification of foundations must be considered. All Anchor Bolts shall conform to ASTM 307. All backfill under slab shall be compacted to 1200 psf. Minimum lap length of splices of reinforcing steel shall be 24 bar diameters unless noted otherwise. Bottom longitudinals are spaced an equal distance apart. #4 and #6 rebar amount is figured on 20' lengths with 24 bar diameter overlaps. NOTE: When using expandable type Anchor Bolt systems, the HILTI® Anchor Kwik-Bolt 1/2” diameter x 7'' or its equivalent is recommended. The absolute minimum embedment is 5 1/2'' with a 10,000 pound pullout. When using the expandable type Anchor Bolt system, the Grain Bin must be round (inside measurement the same in all directions) before drilling and anchoring. WWF must be at or above mid-depth of the Slab. CONCRETE SPECIFICATIONS MODEL NO. 7-01504/08 7-01509/10 7-01511/12 7-01804/08 7-01809/10 7-01811/12 7-02104/08 7-02109/11 7-02112 7-02404/08 7-02409/12 7-02704/08 7-02709/12 7-03004/08 7-03009/12 7-03304/08 7-03309/12 7-03604/08 7-03609/12 7-04204/08 7-04209/12 7-04804/08 7-04809/12 75-05404/11 REINFORCING STEEL TOTAL 3* 19* concrete 20 FOOTER (width) volume NOMINAL WELDED TOP DIAMETER Outside FIRE 21 cu. yds. FABRIC RADIAL Diameter sq. ft. Wall 15' 16'-5 9/16'' 18' 19'-5 3/8'' 21' 22'-5 3/16'' 24' 25' - 5'' 27' 28'-4 13/16'' 30' 31'-4 5/8'' 33' 34'-7/8'' 36' 37'-4 1/4'' 42' 43'-3 7/8'' 48' 54' 49'-3 1/2'' 24'' 24'' 24'' 24'' 24'' 24'' 24'' 24'' 30'' 30'' 30'' 30'' 30'' 10.9 13.8 13.8 13.7 17.3 17.3 16.3 21.1 21.1 19.0 25.1 22.4 29.5 26.0 34.0 28.5 37.0 32.7 43.9 41.0 54.9 49.1 66.9 154 154 154 226 226 226 313 313 313 413 413 527 527 656 656 802 802 955 955 1,309 1,309 1,720 1,720 #4 @ 12'' #4 @ 12'' #4 @ 12'' Approx. REBAR WEIGHT (lbs) 535 775 830 640 925 990 750 1,080 1,155 855 1,080 960 1,210 1,070 1,345 1,150 1,478 1,275 1,610 1,475 1,875 1,700 2,150 See BROCK® Commercial Grain Bin Foundation Manual, MCB1485. Refer to the same Manual for 33' - 48' 13-Ring Bins. MGB1945B 19 Foundation BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Foundation Diagram: 4 - 8 Rings (Metric Measurements) 4 20 9 26 23A 24 3 1 2 8 16 11 5 6 Figure 13. 4-8 Ring Foundation Diagram in METRIC Measurements 12 Item Description 1 Anchor Bolt 12 x 203 x 51, with 165 embedment (See NOTE in Instructions, facing Page 2 12 x 152 Premolded Continuous Expansion Joint Filler 7 Item 152 x 152 MW9 x MW9 Wire Welded Fabric* 4 Projection: 38 5 Vapor Barrier 6 Base Material: 152 7 Clearance: 76.2 8 Clearance: 51 9 Wall Width: 38 10 305 11 152 [may vary from 51-610] 12 Wall height, 914 min. below grade 8 3 13 Bottom Radial: #14 @ 305 14 15 16 17 18 19 20 21 22 23A 23B 24 25 Description Rebar, #4 @ 12'' ea. face, ea. way: 8 Rings: 2-#4 (top), #4 @ 305 max., #4 stirrups @ 305, 3-#4 (bottom); 9-12 Rings: #4 @ 305 # 4 stirrups @ 305 Top Ring: 2 - #4 Bottom Ring: 3 - #4 Middle Rings: 4 @ 305 max. Top Radial* Outside Wall Diameter* Footer Width* Footer Depth 305 Slab Depth 102 thickness Slab Depth 152 thickness Anchor Bolt Circle Radius 18 15 17 See Page 21. 25 Wall Height 1 067 Must not be less than 102 on any Anchor Bolt * See chart column, facing Page. All measurements in millimeters 26 Foundation Diagram: 9 - 12 Rings (Metric Measurements) 1 20 4 11 8 2 9 23B 24 26 3 25 14 8 12 6 5 16 19 22B 10 21 20 8 7 Figure 15. 9-12 Ring Foundation Diagram in METRIC Measurements 13 17 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Foundation Foundation Information in Metric Measurements • • • Concrete in footings shall have a minimum compressive strength, f’c = 20,684 kPa at 28 days. Concrete reinforcing steel shall have a minimum yield strength of 22 527 kPa. Foundations shall be appropriately designed for local soil and frost depth conditions. Sizes given are adequate for resisting 1.5 times the overturning due to a 146.5 kg/m wind acting on 0.6 times area of Grain Bin. Foundations shall be placed on soil of bearing capacity of 14 647 kg/m [3000 psf] or special modification of foundations must be considered. All Anchor Bolts shall conform to ASTM 307. All backfill under slab shall be compacted to 5 859 kg/m . Minimum lap length of splices of reinforcing steel shall be 24 bar diameters unless noted otherwise. Bottom longitudinals are spaced an equal distance apart. #4 and #6 rebar amount is figured on 6 096 lengths with 24 diameter overlaps. NOTE: When using expandable type Anchor Bolt systems, the HILTI® Anchor Kwik-Bolt 13 dia. x 178 [1/2'' diameter x 7''] or its equivalent is recommended. The absolute minimum embedment is 140 mm with a 4 546 kg pullout. When using the expandable type Anchor Bolt system, the Grain Bin must be round (inside measurement the same in all directions) before drilling and anchoring. WWF must be at or above mid-depth of the Slab. ) • • • • • • • • • • 2 2 CONCRETE SPECIFICATIONS Beam 20 MODEL NO. 7-01504/08 7-01509/10 7-01511/12 7-01804/08 7-01809/10 7-01811/12 7-02104/08 7-02109/11 7-02112 7-02404/08 7-02409/12 7-02704/08 7-02709/12 7-03004/08 7-03009/12 7-03304/08 7-03309/12 7-03604/08 7-03609/12 7-04204/08 7-04209/12 7-04804/08 7-04809/12 7-05404/11 MGB1945B NOMINAL Outside DIAMETER Diameter Wall [mm] [mm] 4 572 5 486 6 401 7 315 8 230 9 144 10 058 10 973 12 802 14 630 16 459 * Indicates Grade TOTAL FOOTER concrete (width) volume 21 cu. meters REINFORCING STEEL 3* 19* WELDED FIRE FABRIC sq.meters TOP RADIAL Approx. Rebar Weight kg 8.3 14.3 243 610 10.6 14.3 352 610 10.6 14.3 #4 @ 305 376 10.5 21.0 290 5 928 610 13.2 21.0 420 610 13.2 21.0 #4 @ 305 449 12.5 29.1 340 6 837 610 16.1 29.1 490 610 16.1 29.1 #4 @ 305 524 14.5 38.4 388 7 747 610 19.2 38.4 490 435 17.1 49.0 8 657 549 610 22.6 49.0 19.9 60.9 485 9 566 762 26.0 60.9 610 21.8 74.5 522 10 385 762 28.3 74.5 670 578 25.0 88.7 11 386 730 762 33.6 88.7 31.4 121.6 669 13 205 762 42.0 121.6 850 37.5 159.8 771 15 024 762 51.2 159.8 975 See BROCK® Commercial Grain Bin Foundation Manual, MCB1485. Refer to the same Manual for 10 058 - 14 630 mm 13-Ring Bins. 5 018 21 Foundation BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Locate Anchor Bolts (not supplied standard with the Bin) Take your time. Accuracy will pay. Refer to Figure 16 and the Anchor Bolt Information Chart on the facing Page for measurements on your particular Grain Bin. Layout locations and install anchors BEFORE setting the Grain Bin to insure proper location. Failure to do so may cause damage to the Grain Bin. Use the center pipe and a board or chain again to make the correct diameter to set the Anchor Bolts. The Hilti® Anchor Kwik-Bolt, 1/2'' diameter x 7'', or an equivalent may be used. The anchor must be at least 1/2'' [12.7] diameter with a minimum embedment of 5 1/2'' [139.7]. When Hilti®, or an equivalent type anchor is used, concrete must have 28-day strength to prevent pullout before setting the Grain Bin and tightening Anchors. 2 2 3 1 1 4 4 5 1 1 1 1 1 1 Item 1 2 3 4 5 Description One Bolt Chord Side Chord (High/Aeration Transition) High/Aeration Transition Chord Side Chord, Low Transition Low Transition Chord MGB1390-8 11/98 Figure 15. Anchor Bolt Locations *see facing Page 22 MGB1945B 1 24 No. of Grain Bin Dia. Model No. Anchor Bolts Eng. [Metric] Bolt Circle Radius ft/in One Bolt Chord [mm] in [mm] ft/in 3 2 Five Bolt Chord Side Chord High/Aeration Transition [mm] in [mm] in 5 4 High/ Aeration Transition Chord [mm] Side Chord Low Transition in [mm] Low Transition Chord in [mm] 12' [3 658] 7-01203/9 9 6' - 1 15/16'' [1 870] 56 19/32 '' [1 437] 11' - 4 5/8'' [3 470] 24 3/32'' [612] 65 13/32'' [1 661] 14 1/2'' [368] 82 5/32'' [2 087] 15' [4 572] 7-01504/11 11 7' - 7 13/16'' [2 334] 56 3/4'' [1 442] 15' - 3 5/8'' [4 667] 23 31/32'' [609] 65 13/16'' [1 672] 14 13/32'' [366] 83 3/8'' [2 119] 18' [5 486] 7-01804/11 7-01812* 13 18 9' - 1 3/4'' [2 788] 56 13/16'' [1 443] 38 1/8'' [968] 17' - 8 1/32'' [5 386] 23 29/32'' [607] 14' - 0 5/32'' [4 271] 66'' [1 676] 14 11/32'' [364] 84'' [2 134] 21' [6 401] 7-02104/12 15 10' - 7 5/8'' [3 243] 56 13/16'' [1 443] 19' - 1 31/32'' [5 844] 23 27/32'' [606] 66 1/16'' [1 679] 14 5/16'' [364] 84 5/16'' [2 142] 24' [7 315] 7-02404/12 17 12' - 1 9/16'' [3 697] 56 25/32'' [1 442] 20' - 2 1/16'' [6 418] 23 25/32'' [604] 66 3/32'' [1 679] 14 9/32'' [363] 84 1/2'' [2 146] 27' [8 230] 7-02704/12 19 13' - 7 7/16'' [4 153] 30' [9 144] 7-03004/12 21 15' - 1 3/8'' [4 607] 33' [10 058] 7-03304/13 23 16' - 7 1/4'' [5 063] 56 23/32'' [1 441] 21' - 8 31/32'' [6 630] 23 11/16'' [602] 36' (10 973) 7-03604/11 7-03612/13* 25 36 18' - 1 3/16'' [5 517] 56 11/16'' [1 440] 37 27/32'' [961] 22' - 0 7/16'' [6 717] 23 11/16'' [602] 15' - 3 9/16'' [4 662] 66 3/32'' [1 679] 14 7/32'' [361] 84 3/4'' [2 153] 42' (12 802) 7 04204/10 7-04211/13* 29 42 21' - 1'' [6 426] 56 21/32'' [1 439] 37 13/16'' [960] 22' - 5 7/32'' [6 838] 23 21/32'' [601] 15' - 4 7/8'' [4 696] 66 1/32'' [1 677] 14 3/16'' [360] 84 3/4'' [2 153] 48' (14 630) 7-04804/08 7-04809/13* 33 48 24' - 0 3/4'' [7 336] 56 19/32'' [1 438] 37 25/32'' [960] 22' - 8 7/32'' [6 916] 15' - 5 5/8'' [4 715] 66'' [1 676] 14 3/16'' [360] 84 3/4'' [2 153] 54' (16 459) 7-05404/08 7-05409/11* 7-05412 37 54 72 27' - 0 9/16'' [8 244] 56 3/4'' [1 442] 20' - 10 13/32'' [6 363] 56 3/4'' [1 441] 23 3/4'' [603] 66 3/32'' [1 679] 14 1/4'' [362] 84 19/32'' [2 149] 21' - 4 1/2'' [6 515] 23 23/32'' [602] 66 3/32'' [1 679] 14 1/4'' [362] 84 11/16'' [2 151] 23 5/8'' [600] 66 3/32'' [1 679] 14 7/32'' [362] 84 23/32'' [2 152] BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) MGB1945B Anchor Bolt Information: Farm Grain Bins with TWO and THREE Anchors per Body Sheet 56 9/16'' [1 437] 22' - 10 11/32'' [6 969] 37 3/4'' [959] 15' - 6 5/32'' [4 728] 23 19/32'' [600] 65 31/32'' [1 676] 14 5/32'' [360] 84 23/32'' [2 152] 28 5/16'' [719] 11' - 8 1/2'' [3 569] *These models require THREE Anchors per Sheet. All others require TWO Anchors per Sheet. Anchor bolts are not provided standard with the bin; they must be ordered separately. Foundation 23 Foundation BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Alternate Foundations IMPORTANT! Alternate foundations can ONLY be used for Grain Bins nine (9) Rings or less, where floor and wall are made in a continuous pour. CONCRETE INFORMATION Model No. ft 7-01203/09 7-01504/09 7-01804/09 7-02104/09 7-02404-09 7-02704/09 7-03004/09 7-03304-09 7-03604/09 7-04204/09 7-04804/08 7-04809 7-05404/09 Outside Diameter Nominal Diameter 20 [mm] Total Weight of Rebar * Welded Wire Fabric ** No. of Anchors 2 cu. [cu. m] lbs. [kg] ft [m ] yds. 12' 9'' [3 886] 5.0 [3.8] 28 [12.7] 128 [11.9] 9 15' 9'' [4 801] 5.6 [4.3] 35 [15.9] 195 [18.1] 11 18' 10'' [5 740] 7.1 [5.4] 42 [19.1] 279 [25.9] 13 21' 10'' [6 655] 8.9 [6.8] 49 [22.2] 375 [34.8] 15 24' 9'' [7 544] 10.9 [8.3] 56 [25.4] 481 [44.7] 17 27' 9'' [8 458] 13.0 [9.9] 63 [28.6] 605 [56.2] 19 30' 9'' [9 373] 15.3 [11.7] 70 [31.8] 743 [69.0] 21 33' 8 1/2'' [10 274] 17.2 [13.2] 77 [34.9] 892 [82.9] 23 36' 9'' [11 201] 20.5 [15.7] 84 [38.1] 1061 [98.6] 25 42' 9'' [13 030] 25.7 [19.7] 98 [44.5] 1435 [133.3] 29 48' 9'' [14 859] 32.2 [24.6] 112 [50.8] 1867 [173.5] 33 48' 9'' [14 859] 32.2 [24.6] 112 [50.8] 1867 [173.5] 48 See BROCK® Commercial Grain Bin Foundation Manual, MCB1485, or Metric Foundation Manual, MCB1342. ft 12' [3 658] 15' [4 572] 18' [5 486] 21' [6 401] 24' [7 544] 27' [8 230] 30' [9 144] 33' [10 058] 36' [10 973] 42' [12 802] 48' [14 630] 48' [14 630] 54' [16 459] Total Concrete Volume REINFORCING STEEL [mm] 2 2 * Weight of reinforcing steel is based on 20' 0'' [6 096] lengths and 12'' [305] lap splice. ** Quantity of welded wire fabric is based on actual inplace area. Waste and laps not included. Concrete MIXTURE: 3000 psi [20 684 kPa] compression at 28 days minimum. REINFORCING STEEL bars: 33,000 psi [227 527 kPa] minimum yield strength. 24 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Foundation 20 10 11 1 25 24 2 8 6 5 3 9 8 4 7 8 Figure 16. Alternate Foundation Item 1 2 3 4 5 6 7 8 9 10 11 20 24 25 MGB1945B Description Anchor Bolt 1/2'' dia. x 8'' x 2'' [13 x 203 x 51] 6'' x 6'' [152 x 152 mm] W1.4xW1.4 Welded Wire Fabric 6'' [152] Base Material w/Vapor Barrier Footer Width 12'' [305] Footer Depth 18'' [457] min.: NOTE: Footer depth dimension must be adjusted for local frost and soil requirements. Slab Depth 4'' [102] 2-#3 Bar Rings 2'' [51] clearance typical 3'' [76] clearance 1 1/2'' [38] projection For additional height (2'' [51] normal, 24'' [610] maximum) from grade to top of footer (and slab) the Item 5 dimension must be increased accordingly and more #3 bar rings (Item 7) added with a 16'' [406] maximum vertical height between Rings. Outside diameter of Wall Anchor Bolt Radius Must not be less than 4'' [102] on any Anchor Bolt 25 Construction Overview BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Construction Overview Construction Begins with the Top Ring of the Tank: IMPORTANT: No Caulking is used where the Roof sections attach to the Top Ring. Top Body Sheets, Hardware and Caulking: (see the section “Assemble the Top Ring First” on Page 31 in this Manual) Build the Roof on the Top Ring After the Top Ring is built, consult your Roof Manual to build the Roof. Manual Part No. Diameter Type MCB1496 15' - 48' [4 572 - 14 630] Farm Roof MCB1484 48' - 54' [14 630 - 16 459] Commercial Roof Read carefully the following sections on Jacks and raising the Grain Bin so that proper equipment will be in place to lift the construction. Lift the Roof and Top Ring to continue construction of the Tank walls When the Roof is complete and the Roof/Top Ring are raised, return to this Manual and repeat the Body Sheet bolting/caulking instructions for the second Ring down. Repeat throughout the remainder of the Tank. Further information as gauges change, see the BODY SHEET PART NUMBER Listing and Layout Diagrams in this Manual, Pages 36-39. Accessories such as Ladders and Cages are installed every one or two Rings as the Tank is built and depending the length of the Ladder section. Refer to your BROCK® Outside Ladder Manual (MGB1538) or BROCK® Platform Manual (MCB1352) for proper instructions. Instructions are shipped separately with optional Accessory items. Set, seal and ground the Tank After completing the bottom Ring, level the Tank, shim the Stiffeners (if applicable), seal the base of the Tank and securely anchor the Tank to the foundation. See the section “Setting and Sealing the Grain Bin.” 26 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Construction Overview 5 4 3 16 Consult your Roof Manual. 2 1 1 17 7 8 Consult this Manual. 6 18 10 15 Consult your Door Supplement Manual. 11 9 15 14 12 13 Figure 17. Assembly Overview Item 1 2 3 4 5 6 7 8 9 MGB1945B Description Top Body Sheet Ring Roof Lid Roof Ladder Manhole (shape varies) Vertical Seam Horizontal Seam Intermediate Body Sheet Outside Ladder Item 10 11 12 13 14 15 16 17 18 Description Inside Ladder Door Door Step Bottom Ring Foundation Door Short Sheets Roof Height Eave Height Overall Height 27 Construction Overview BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Choosing the Proper Jacks to Lift the Grain Bin Jacks are used to lift the Grain Bin slowly and evenly during assembly of the Body Sheets. The Jack shown in Figure 18 is only a representation. Jacks should be designed using accepted engineering practices, taking into account the dead and live loads associated with construction. Jacks must be used on every Sheet on 42' - 48' [12 802 - 14 630] diameter Grain Bins. At least one jack for every other Sheet (every Sheet is best) for 15' [4 572] through 36' [10 973] is recommended. Determine the number of jacks required for the weight of the Grain Bin. Jacks must be able to hold twice the weight of the Grain Bin. Bolts must be adequate for lifting the load. (Lift Brackets Bolts are not included in the Bolt count.) IMPORTANT! The jack represented in Figure 18 is not adequate for all sizes of Grain Bins. On larger Grain Bins, electric or hydraulic jacks are recommended. Consult the jack manufacturer for instructions. CAUTION! Do not jack the Grain Bin under windy conditions! This could result in Tank damage. Read “SAFETY Procedures During Jacking” on the facing page. 1 7 2 IMPORTANT: Read carefully and follow the lifting instructions particular to your diameter Grain Bin. Improper design or use of jacks may result in damage to the Grain Bin and/or personal injury. 3 Item Description 1 Pulley 2 Lift Bracket 3 Hand Winch 4 Concrete Anchors recommended 5 Base (must rest on concrete) 6 Stake 7 Stabilizers 6 4 5 Figure 18. Jack with Pulley and Hand Winch 28 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Construction Overview SAFETY Procedures During Jacking 1. Be sure Jacks and cables are anchored securely. 2. Position vertical seams at Anchor Bolts. Also verify locations of Roof Manhole, Ladders, Access Door and Side Discharge system before starting to raise the Tank. 3. When jacking, raise the Tank just enough to add one new Ring of Body Sheets. (Caulk horizontal and vertical seams.) 4. Start assembly of each new Ring of Body Sheets on the windward side of the Tank. See Figure 19. 5. Leave all Bolts loose in the new Ring until all Sheets have been attached. 6. Attach Ladders Cages, and Platforms. 7. Repeat Steps 3 - 4 as new Rings are being added. 8. Install the Door Access Sheets in the bottom two Rings. Install the Door. 9. Lower the Tank and secure to the foundation before the leaving the job site. 10. Follow the jack manufacturer’s recommendations for capacity and operations. Item Description 1 Existing Ring 2 New Ring below 3 Windward Side 2 1 3 TOP VIEW Figure 19. Rings on Windward Side MGB1945B 29 Grain Bin Assembly BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Grain Bin Assembly Body Sheet Identification Each Ring or layer of Body Sheets is identified by a color. Each Sheet in the Ring is identified by a number. A strip of colored tape with a number is located on the inside of each Body Sheet. This helps locate each Body Sheet on the chart. Heavier gauge material is sometimes substituted for the Door Short Sheets. Material Thickness Gauge in .035 .046 .053 .058 .065 .072 .088 .102 .118 .136 .150 .165 20 18 17 16 15 14 13 12 11 10 9 8 [mm] [0.88] [1.18] [1.34] [1.47] [1.66] [1.82] [2.25] [2.59] [2.99] [3.45] [3.80] [4.20] Color white pink yellow orange light blue dark green gray dark blue light green black copper silver Caulking Body Sheets Wipe the Body Sheets clean where the Caulking is to be applied. No Caulking is used where the Roof sections attach. Place a bead of Caulking along both sides of vertical and top side of horizontal holes before the next Body Sheet is attached. See Figure 20. Caulk as close to holes as possible. Use plenty of Caulking. Overlap Top Body Sheets outside of Bottom Sheets. 2 Item Description 1 Body Sheet 2 Caulk 1 Figure 20. Caulking Detail 30 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Grain Bin Assembly Assemble the Top Ring First Refer to “Body Sheet Parts Listing” on Pages 36-39. Use a drift punch to align vertical holes and insert Bolts, heads on outside. Bolt the Sheets end-to-end, overlapping the same way throughout, until the Ring is complete. Attach lifting brackets at the bottom of the seams while bolting the Body Sheets together. 5/16 x 1'' Bin Seal Bolts are used in all Sheets unless specifically noted otherwise in “Body Sheet Parts Listing.” 3/8 x 1'' (or 1 1/4'') Bolts are used on certain height models. Refer to the Body Sheet Gauge Chart on Page 30 and Pages 36-39 for the proper Body Sheet and Gauge schedule. Note Bolt specifications for each gauge. Use a drift punch to align vertical holes and insert Bolts, heads on outside. Bolt sheets end-to-end, overlapping the same way throughout, until the Ring is complete. See Figure 19. IMPORTANT! All Bolts must be tightened from the Nut side. Attach lifting brackets while bolting the Body Sheets together. TOP VIEW TOP VIEW 3 2 5 1 or 6 4 2 3 2 Item Description 1 Vertical Seam 2 Body Sheet 3 Caulk 4 Bin Seal Bolt 5 Plastic Bin Seal Bolt 6 Hex Nut Vertical Seam Detail 6 5 or 4 3 2 2 SIDE VIEW Figure 21. Top Body Sheet Ring MGB1945B 31 Grain Bin Assembly IMPORTANT! BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Vertical Seams are fastened with Bin Seal Bolts and Hex Nuts. All Bolts must be tightened from the Nut side. Refer closely to the BODY SHEET CHARTS for the specific hardware for the Ring you are installing. Note Bolt specifications for each gauge. Use a drift punch to align vertical holes and insert Bolts, heads on the outside. Build your roof according to your Roof Manual With the top Body Sheet in place, assemble the Roof. Roof construction procedures vary with Grain Bin diameter. Refer to your Roof Manual Supplement: Manual Diameter Type Part No. MCB1496 15' - 48' [4 572 - 14 630] Farm Roof MCB1484 48' - 54' [14 630 - 16 459] Commercial Roof IMPORTANT! Complete the entire Roof. Return to this Page to continue the Tank. Figure 22. First Ring and Roof on Jacks Adding Body Sheet Rings Caulk horizontal and vertical seams as shown in Figure 18. As you add Body Rings, refer to Body Sheet Identification Charts for correct Sheet locations and Bolt specifications. Note that 48' and 54' Commercial Roofs have special Rafter Stiffener information in Figure 23. In the first Ring down from the Roof, apply the BROCK® Decal in the center of a Body Sheet. On Rings with a Door Sheet, start at the Door opening and work your way around, adding Sheets. 10 Item 1 3 5 6 7 8 10 11 Description *Rafter Attachment Stiffener (12 ga. w/ 1'' [25.4] dia. holes in center) Roof Rib Top Body Sheet 3 round holes go UP 2 slotted holes go DOWN Hex Nut 3/8'' Bin Seal Gr. 8.2 Bolts Flat Washer (refer to step #4 above) SIDE VIEW 3 6 1 11 8 7 5 Figure 23. Rafter Attachment Stiffener, 48' and 54' [14 630] Dia. Commercial Roof 32 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Grain Bin Assembly Door The Door is installed in the second and third Rings from the bottom. It must be installed before the bottom Ring is installed. Refer to your Door Manual Supplement, LATCH-LOCK® No. 1, No. 2 and No. 3 Doors (MGB1580), for installation and Body Sheet layout around the Door. See the Hopper Bin Door Manual MHB1421 for a 12' Bin. Exterior Sidewall Stiffener Assembly Policy NOTE: All Grain Bins using Bottom Drying Discharge or Recirculating Equipment require two Stiffeners per Sheet and additional Floor Supports. This includes all Rings except the top Ring on odd-Ring Grain Bins. Grain Bins containing Grain Bin Wall Liners or Air Tube Systems do not require Stiffeners for stirring machines. A Standard Grain Bin may be used with four or fewer down augers. Any Grain Bin using a Stirring Device with more than four down augers requires one Stiffener per Sheet on bottom four Rings or a Heavy Grain Bin. The Exterior Sidewall Stiffener must be installed with the hole closest to the end of the Stiffener at the bottom. 12 1 4 11 2 Figure 24. Recommended Location of Stiffeners 3 9 8 8 10 1 6 7 13 Figure 25. Stiffeners, Side View MGB1945B 5 Item Part No. 1 9-27022 2 3 4 5 6 9-27023 9-27024 varies varies 39-20152 7 39-20113 8 39-20114 9 39-20172 10 39-20294 11 39-20297 12 13 Description Qty. Exterior Sidewall 2 Stiffener Angle Splicer 2 Shim 2 Body Sheet varies Base Angle varies Flange Nut 5/16'' 7 Bin Seal Bolt 3/8 x 16 1'' Gr. 8.2 Hex Nut 3/8'' 16 Weather Seal 16 Washer 3/8'' Hex Head Bolt 1 5/16 x 3'' Gr. 5 Hex Head Bolt 6 5/16 x 3/4'' Gr. 5 1.25'' [32] 2.25'' [57] 33 Anchoring Assembly BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Anchoring Assembly Concrete must be level to within 1/4" [6.4] in 10 feet [3 048] and 1/2" [12.7] total. Any high spots or debris must be removed before setting the Tank. See Page 23 for the number of Anchor Bolts required. With the Grain Bin slightly suspended, install the Base Angle Ring and apply the Foundation Sealant (or a heavy layer of black mastic) to the underside. Additional sealant should be placed only on the inside of the Grain Bin. Caulk between the Base Angle and the Body Sheet full length. NOTE: There is no Base Angle Ring in the area of the Transition. One Anchor is used on each side of fan transition. The top two Bolts in the Bracket are not required when Anchor is not at the vertical seam. A Weatherseal Washer is required under Nut on all Bolts that secure Anchors. Anchor Bolts must be properly located and be no closer than 4'' [102] from the inner or outer edge of the Stemwall concrete. Anchors per Grain Bin Model Quantity 7-01203/9 9 7-01504/11 11 7-01804/11 13 7-01812 18 7-02104/12 15 7-02404/12 17 7-02704/12 19 7-03004/12 21 7-03304/13 23 7-03604/11 25 7-03612/13 36 7-04204/10 29 7-04211/13 42 33 7-04804/08 48 7-04809/13 37 7-05404/08 54 7-05409/11 72 7-05412 4 5 9 8 1 6 7 2 3 Anchor bolts are not provided standard with the bin. They must be ordered separately. 4 Item Description 1 Body Sheet (varies) 2 Base Angle Ring (varies) 3 Anchor Plate 9-22778 4 Grain Bin Anchor Bracket 9-22779 5 Bin Seal Bolt 6 1/2'' Hex Nut 7 1/2'' Anchor Bolt 8 Weatherseal Washer 9 Hex Nut Figure 25. Anchoring Detail 34 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Grain Bin Grounding Grain Bin Grounding All Grain Bins shall have two Ground Connections. Ground Clamps must be spaced equally around the Grain Bin. For alternate installations, cables may be placed in the foundation or through a PVC sleeve inserted in the slab during construction. Make sure electrical equipment is properly installed and grounded by a qualified electrician according to the National Electrical Code. 1 2 3 4 5 Item Description 1 238B Bronze Heavy Duty Metal Bonding Plate 2 306 A Swivel Cable Clamp 3 Copper Cable 4 Ground Rod Clamp 5 Ground Rod NOTE: Parts should be purchased locally. Figure 26. Grounding Illustration MGB1945B 35 Body Sheet Layouts BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Body Sheet Layouts 12' [3 658] Diameter MODEL 1203 1204 1205 RING Gauge 20 18 17 16 15 14 13 12 11 10 9 8 Material Thickness in mm .035 .046 .053 .058 .065 .072 .088 .102 .118 .136 .150 .165 [0.88] [1.18] [1.34] [1.47] [1.66] [1.82] [2.25] [2.59] [2.99] [3.45] [3.80] [4.20] 1 2 3 4 5 6 7 8 9 Color white pink yellow orange light blue dark green gray dark blue light green black copper silver 1206 1207 1208 1209 20 20 20 18 17 16 13 20 20 20 18 17 16 15 13 20 20 20 18 17 15 14 13 13 GAUGES 20 20 16 20 20 20 16 20 20 20 18 16 20 20 20 18 17 16 There are FOUR Body Sheets per Ring. 15' [4 572] Diameter MODEL 1504 1505 1506 RING 1 2 3 4 5 6 7 8 9 10 11 Door Short Sheets are of the same or heavier gauge as a complete Ring. The Two-Ring Door is located in the second and third Rings from the bottom. See Figure 17 or the Door Manual MGB1580 for the Body Sheet layout around the Door. 1507 1508 1509 1510 1511 20 20 18 18 17 15 15 13 13 20 20 18 18 17 15 14 13 13 12 20 20 18 17 16 15 14 13 13 12 12 GAUGES 20 20 18 16 20 20 18 18 16 20 20 18 18 17 13 20 20 18 18 17 15 13 20 20 18 18 17 15 15 13 There are FIVE Body Sheets per Ring. 18' [5 486] Diameter MODEL 1804 1805 1806 1807 RING 1 2 3 4 5 6 7 8 9 10 11 12 1808 1809 1810 1811 1812 20 20 18 18 17 15 14 13 13 20 20 18 18 17 15 14 13 13 12 20 20 18 18 17 15 14 13 13 12 12 20 20 18 18 16 15 14 13 13 12 12 11 GAUGES 20 20 18 16 20 20 18 18 16 20 20 18 18 17 13 20 20 18 18 17 15 13 20 20 18 18 17 15 14 13 There are SIX Body Sheets per Ring. 36 MGB1945B Body Sheet Layouts BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) 21' [6 401] Diameter MODEL 2104 2105 2106 2107 RING Gauge 20 18 17 16 15 14 13 12 11 10 9 8 Material Thickness in mm .035 .046 .053 .058 .065 .072 .088 .102 .118 .136 .150 .165 [0.88] [1.18] [1.34] [1.47] [1.66] [1.82] [2.25] [2.59] [2.99] [3.45] [3.80] [4.20] Color 1 2 3 4 5 6 7 8 9 10 11 12 2108 2109 2110 2111 2112 20 20 18 18 16 15 14 13 13 20 20 18 18 16 15 14 13 13 12 20 20 18 18 16 15 14 13 13 12 12 20 20 18 18 16 15 14 13 13 12 12 11 GAUGES 20 20 18 16 20 20 18 18 16 20 20 18 18 16 13 20 20 18 18 16 15 13 20 20 18 18 16 15 14 13 There are SEVEN Body Sheets per Ring. white pink yellow orange light blue dark green gray dark blue light green black copper silver Door Short Sheets are of the same or heavier gauge as a complete Ring. The Two-Ring Door is located in the second and third Rings from the bottom. See Figure 17 or the Door Manual MGB1580 for the Body Sheet layout around the Door. 24' [7 315] Diameter MODEL 2404 2405 2406 2407 RING 1 2 3 4 5 6 7 8 9 10 11 12 2408 2409 2410 2411 2412 20 20 18 17 16 15 14 13 13 20 20 18 17 16 15 14 13 13 12 20 20 18 17 16 15 14 13 13 12 12 20 20 18 17 16 15 14 13 13 12 12 11 GAUGES 20 20 18 16 20 20 18 17 16 20 20 18 17 16 13 20 20 18 17 16 15 13 20 20 18 17 16 15 14 13 There are EIGHT Body Sheets per Ring. 27' [8 230] Diameter MODEL 2704 2705 2706 2707 RING 1 2 3 4 5 6 7 8 9 10 11 12 2708 2709 2710 2711 2712 20 20 18 17 16 15 13 13 12 20 20 18 17 16 15 14 13 12 12 20 20 18 17 16 15 14 13 12 12 12 20 20 18 17 16 15 14 13 12 12 12 11 GAUGES 20 20 18 16 20 20 18 17 16 20 20 18 17 16 13 20 20 18 17 16 15 13 20 20 18 17 16 15 13 13 There are NINE Body Sheets per Ring. MGB1945B 37 Body Sheet Layouts BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) 30' [9 144] Diameter MODEL 3004 3005 3006 3007 RING Gauge 20 18 17 16 15 14 13 12 11 10 9 8 Material Thickness in mm .035 .046 .053 .058 .065 .072 .088 .102 .118 .136 .150 .165 [0.88] [1.18] [1.34] [1.47] [1.66] [1.82] [2.25] [2.59] [2.99] [3.45] [3.80] [4.20] Color white pink yellow orange light blue dark green gray dark blue light green black copper silver Door Short Sheets are of the same or heavier gauge as a complete Ring. The Two-Ring Door is located in the second and third Rings from the bottom. See Figure 17 or the Door Manual MGB1580 for the Body Sheet layout around the Door. 1 2 3 4 5 6 7 8 9 10 11 12 13 3008 3009 3010 3011 3012 3013 20 20 18 17 15 14 13 13 12 12 20 20 18 17 15 14 13 13 12 12 11 20 20 18 17 15 14 13 13 12 12 11 11 20 20 18 17 15 14 13 13 12 12 11 11 10 GAUGES 20 20 18 16 20 20 18 17 13 20 20 18 17 15 13 20 20 18 17 15 14 13 20 20 18 17 15 14 13 13 20 20 18 17 15 14 13 13 12 There are TEN Body Sheets per Ring. Use 3/8 x 1'' Gr. 8.2 Bin Seal Bolts in all vertical and horizontal seams of this Ring. 33' [10 058] Diameter MODEL 3304 RING 1 2 3 4 5 6 7 8 9 10 11 12 13 18 18 18 16 3305 3306 3307 18 18 18 17 13 18 18 18 17 15 13 18 18 18 17 15 14 13 3308 3309 GAUGES 18 18 18 17 15 14 13 13 18 18 18 17 15 14 13 13 12 3310 3311 3312 3313 18 18 18 17 15 14 13 13 12 12 18 18 18 17 15 14 13 13 12 12 11 18 18 18 17 15 14 13 13 12 12 11 11 18 18 18 17 15 14 13 13 12 12 11 11 10 There are ELEVEN Body Sheets per Ring. Use 3/8 x 1'' Gr. 8.2 Bin Seal Bolts in all vertical and horizontal seams of this Ring. 36' [10 973] Diameter MODEL 3604 RING 1 2 3 4 5 6 7 8 9 10 11 12 13 18 18 18 16 3605 3606 3607 18 18 18 17 13 18 18 18 17 15 13 18 18 18 17 15 14 13 3608 3609 GAUGES 18 18 18 17 15 14 13 12 18 18 18 17 15 14 13 13 12 3610 3611 18 18 18 17 15 14 13 13 12 12 18 18 18 17 15 14 13 13 12 12 11 3612 3613 18 18 18 18 18 18 17 17 15 15 14 14 13 13 13 13 12 12 12 12 11 11 10 10 10 There are TWELVE Body Sheets per Ring. Use 3/8 x 1'' Gr. 8.2 Bin Seal Bolts in all vertical and horizontal seams of this Ring. 38 MGB1945B Body Sheet Layouts BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) 42' [12 802] Diameter Gauge 20 18 17 16 15 14 13 12 11 10 9 8 Material Thickness in mm .035 .046 .053 .058 .065 .072 .088 .102 .118 .136 .150 .165 [0.88] [1.18] [1.34] [1.47] [1.66] [1.82] [2.25] [2.59] [2.99] [3.45] [3.80] [4.20] Color white pink yellow orange light blue dark green gray dark blue light green black copper silver MODEL RING 4204 4205 4206 4207 1 2 3 4 5 6 7 8 9 10 11 12 13 17 18 17 16 17 18 17 16 13 17 18 17 16 15 13 17 18 17 16 15 14 13 17 18 17 16 15 14 13 12 4210 4211 4212 4213 17 18 17 16 15 14 13 13 12 11 17 18 17 16 15 14 13 13 12 11 10 17 18 17 16 15 14 13 13 12 11 10 • 8• 17 18 17 16 15 14 13 13 12 11 10 • 9• 8• 17 18 17 16 15 14 13 12 11 There are FOURTEEN Body Sheets per Ring. Use 3/8 x 1'' Gr. 8.2 Bin Seal Bolts in all vertical and horizontal seams of this Ring. • Use 3/8 x 1 1/4'' Gr. 8.2 Bin Seal Bolts in all vertical and horizontal seams of this Ring. 48' [14 630] Diameter MODEL 4804 RING 1 2 3 4 5 6 7 8 9 10 11 12 13 Door Short Sheets are of the same or heavier gauge as a complete Ring. The Two-Ring Door is located in the second and third Rings from the bottom. See Figure 17 or the Door Manual MGB1580 for the Body Sheet layout around the Door. 4208 4209 GAUGES 17 18 17 16 4805 4806 4807 17 18 17 16 13 17 18 17 16 14 13 17 18 17 16 14 13 12 4808 4809 GAUGES 17 18 17 16 14 13 12 11 17 18 17 16 14 13 12 11 10 4810 4811 4812 4813 17 18 17 16 14 13 13 12 11 10 17 18 17 16 14 13 13 12 11 10 • 8• 17 18 17 16 14 13 13 12 11 10 • 9• 8• 17 18 17 16 14 13 13 12 11 10 • 9• 8• 8• There are SIXTEEN Body Sheets per Ring. 2-Ring Door No. 3 is used in these sizes. Use 3/8 x 1'' Gr. 8.2 Bin Seal Bolts in all vertical and horizontal seams of this Ring. • Use 3/8 x 1 1/4''Gr. 8.2 Bin Seal Bolts in all vertical and horizontal seams of this Ring. 54' [16 459] Diameter MODEL 5404 RING 1 2 3 4 5 6 7 8 9 10 11 12 16 18 17 13 5405 5406 5407 16 18 17 15 13 16 18 17 15 14 13 16 18 17 15 14 13 12 5408 5409 GAUGES 16 18 17 15 14 13 12 11 16 18 17 15 14 13 12 11 10 5410 5411 5412 16 18 17 15 14 13 12 11 10 • 8• 16 18 17 15 14 13 12 11 10 • 9• 8• 16 18 17 15 14 13 12 11 10 • 9• 8• 8• There are EIGHTEEN Body Sheets per Ring. 2-Ring Door No. 3 is used in these sizes. Use 3/8 x 1'' Gr. 8.2 Bin Seal Bolts in all vertical and horizontal seams of this Ring. • Use 3/8 x 1 1/4''Gr. 8.2 Bin Seal Bolts in all vertical and horizontal seams of this Ring. Top Ring Sheets (9-26415-54) are punched for the Top Stiffener. MGB1945B 39 Body Sheet Layouts BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Recirculating Grain Bin Gauge Schedule 24' Dia. [7 315] 27' Dia. [8 230] 30' Dia. [9 144] 33' Dia. [10 058] 36' Dia. [10 973] R27-02407 R27-02408 R27-02707 R27-02708 R27-03007 R27-03008 R27-03307 R27-03308 R27-03607 R27-03608 RING 1 2 3 4 5 6 7 8 GAUGES 18 18 15 14 13 12 12 18 18 15 14 13 12 12 11 18 18 15 14 13 12 12 18 18 15 14 13 12 12 11 18 18 15 14 13 12 12 18 18 15 14 13 12 12 11 18 18 15 14 13 12 11 18 18 15 14 13 12 11 11 18 18 14 13 12 12 11 18 18 14 13 12 12 11 11 Heavy Body Sheet Gauge Schedule Seven-Ring Grain Bins Gauge 20 18 17 16 15 14 13 12 11 10 9 8 Material Thickness in mm .035 .046 .053 .058 .065 .072 .088 .102 .118 .136 .150 .165 [0.88] [1.18] [1.34] [1.47] [1.66] [1.82] [2.25] [2.59] [2.99] [3.45] [3.80] [4.20] 33' Dia. [10 058] 18 18 16 16 14 14 13 18 18 16 16 14 14 13 RING Color white pink yellow orange light blue dark green gray dark blue light green black copper silver Door Short Sheets are of the same or heavier gauge as a complete Ring. The Two-Ring Door is located in the second and third Rings from the bottom. See Figure 17 or the Door Manual MGB1580 for the Body Sheet layout around the Door. 40 30' Dia. [9 144] 1 2 3 4 5 6 7 36' Dia. [10 973] 42' Dia. [12 802] 48' Dia. [14 630] 16 16 16 14 14 13 12 16 16 16 14 14 12 12 42' Dia. [12 802] 48' Dia. [14 630] 16 16 16 14 14 13 12 12 16 16 16 14 14 12 12 11 GAUGES 18 18 16 14 14 13 12 Eight-Ring Grain Bins 30' Dia. [9 144] 33' Dia. [10 058] 18 18 16 16 14 14 13 12 18 18 16 16 14 14 13 12 RING 1 2 3 4 5 6 7 8 36' Dia. [10 973] GAUGES 18 18 16 14 14 13 12 12 MGB1945B Top Body Sheets - 115.75 in. [2 940] long - used with Commercial Roof GAUGE 16 Standard Weight 12' Dia. 15' Dia. (pounds) [3 658] [4 572] orange 68.0 Body Sheets - 115.75 in. [2 940] long 21' Dia. [6 401] 24' Dia. [7 315] 27' Dia. [8 230] 30' Dia. [9 144] 33' Dia. [10 058] 36' Dia. [10 973] 42' Dia. [12 802] GAUGE COLOR 20 18 17 16 15 14 13 12 11 10 9 8 white pink yellow orange lt. blue dk. green gray dk. blue lt. green black copper silver Weight (pounds) 40.9 54.2 61.9 68.1 76.7s 83.8 103.1 118.7 136.4 156.3 170.9 187.9 12' Dia. [3 658] 9-32387 9-32389 9-32390 9-32391 9-32392 9-32393 9-32394 48' Dia. 54' Dia. [14 630] [16 459] 9-45634-48 9-45634-54 15' Dia. [4 572] 9-12867 9-14256 9-12868 9-12870 9-28123 9-12872 9-28133 9-18840 9-28134 18' Dia. [5 485] 9-11239 9-14257 9-12243 9-11243 9-28124 9-11245 9-27928 9-18857 9-28139 21' Dia. [6 401] 9-11249 9-14258 9-12245 9-11253 9-28125 9-11255 9-27929 9-18867 9-28140 9-27347 24' Dia. [7 315] 9-10681 9-14259 9-12249 9-10677 9-28126 9-10675 9-27930 9-18878 9-28141 9-27352 9-28170-24 27' Dia. [8 230] 9-11008 9-14260 9-12253 9-11012 9-28127 9-11014 9-27931 9-18890 9-28142 9-27357 30' Dia. [9 144] 9-11024 9-14261 9-12388 9-11028 9-28128 9-11030 9-27932 9-18900 9-27960 9-18901 33' Dia. [10 058] 9-28111 9-16708 9-16709 9-16710 9-28129 9-16712 9-27933 9-18914 9-27961 9-18915 36' Dia. [10 973] 42' Dia. [12 802] 48' Dia. [14 630] 54' Dia. [16 459] 9-14262 9-12389 9-11616 9-28130 9-11618 9-27934 9-18928 9-27962 9-18929 9-28155 9-18818-36 9-27379 9-17978 9-17953 9-28131 9-17955 9-27955 9-18940 9-27963 9-18941 9-28159 9-27380 9-28171 9-17979 9-17957 9-28132 9-17959 9-27936 9-18952 9-27964 9-18953 9-28164 9-18954 9-15766-54 9-15767-54 9-26415-54 9-28110-54 9-15770-54 9-27981-54 9-18815-54 9-27986-54 9-18817-54 9-28170-54 9-18818-54 15' Dia. [4 572] 18' Dia. [5 485] 21' Dia. [6 401] 24' Dia. [7 315] 27' Dia. [8 230] 30' Dia. [9 144] 33' Dia. [10 058] 36' Dia. [10 973] 42' Dia. [12 802] 48' Dia. [14 630] 54' Dia. [16 459] 9-11244 9-27937 9-27588 9-11244 9-27937 9-27588 9-11244 9-27937 9-27588 9-11013 9-27938 9-27589 9-11013 9-27938 9-27589 9-11013 9-27938 9-27589 9-11617 9-27939 9-27965 9-11617 9-27939 9-27965 15' Dia. [4 572] 9-18846 9-13893 9-28135 9-18847 9-28136 18' Dia. [5 485] 9-18859 9-13899 9-27942 9-18860 9-28146 9-28152 21' Dia. [6 401] 9-18870 9-13904 9-27943 9-18871 9-28147 9-27349 24' Dia. [7 315] 9-18882 9-13908 9-27944 9-18883 9-28148 9-27354 27' Dia. [8 230] 9-18892 9-13912 9-27945 9-18893 9-28149 9-27359 30' Dia. [9 144] 9-18903 9-13915 9-27995 9-18904 9-27968 9-18905 33' Dia. [10 058] 9-18917 9-16714 9-27946 9-18918 9-27969 9-18919 36' Dia. [10 973] 9-28143 9-13918 9-27947 9-18932 9-27970 9-18933 Door Sheets - 78.25 in. [1 988] long GAUGE COLOR Weight (pounds) 12' Dia. [3 658] 115.75'' long 16 orange 46.0 9-32396 13 gray 69.7 9-32398 11 lt. green 92.2 8 silver 126.9 12' [3,658] Door Sheets are 115.75'' [2 940] long 9-17954 9-17958 9-27940 9-27941 9-27966 9-27967 9-37665-42 9-37665-48 9-15803-54 9-27982-54 9-27987-54 9-37665-54 Plenum Sheets - 115.75 in. [2 940] long 41 GAUGE COLOR 16 14 13 12 11 10 8 orange dk. green gray dk. blue lt. green black silver Weight (pounds) 68.0 83.8 103.1 118.6 136.4 156.3 187.8 12' Dia. [3 658] 9-32400 9-32401 9-32402 42' Dia. [12 802] 9-28160 9-13921 9-27948 9-18944 9-27971 9-18945 9-29382 48' Dia. [14 630] 9-28165 9-13925 9-27949 9-18957 9-27972 9-18958 9-18959 54' Dia. [16 459] 9-15755-54 9-27983-54 9-18826-54 9-27988-54 9-18828-54 9-18829-54 Farm Grain Bin Body Sheet Part Number Charts 18' Dia. [5 485] COLOR BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) MGB1945B Farm Grain Bin Body Sheet Part Number Charts GAUGE COLOR 14 11 8 dk. green lt. green silver Weight 15' Dia. 18' Dia. 21' Dia. 24' Dia. 27' Dia. 30' Dia. 33' Dia. (pounds) [4 572] [5 485] [6 401] [7 315] [8 230] [9 144] [10 058] 62.6 9-39735-15 9-39735-18 9-39735-21 9-39735-24 9-39735-27 9-39735-30 9-39735-33 101.8 9-39736-15 9-39736-18 9-39736-21 9-39736-24 9-39736-27 9-39736-30 9-39736-33 140.3 36' Dia. [10 973] 9-39735-36 9-39736-36 9-39737-36 42' Dia. [12 802] 9-39735-42 9-39736-42 9-39737-42 36' Dia. [10 973] 9-18937 9-27957 9-18938 9-18939 42' Dia. [12 802] 9-18949 9-27958 9-18950 9-18951 9-27384 36' Dia. [10 973] 9-39738-36 9-39739-36 9-39740-36 42' Dia. [12 802] 9-39738-42 9-39739-42 9-39740-42 48' Dia. 54' Dia. [14 630] [16 459] 9-39735-48 9-39735-54 9-39736-48 9-39736-54 9-39737-48 9-39737-54 Low Fan Transition Sheets - 115.75 in. [2 940] long GAUGE COLOR 14 13 12 10 8 dk. green gray dk. blue black silver Weight (pounds) 63.2 76.9 89.5 117.7 141.7 15' Dia. [4 572] 9-18865 9-27955 9-18866 9-27351 18' Dia. [5 485] 9-18865 9-27955 9-18866 9-27351 21' Dia. [6 401] 9-18865 9-27955 9-18866 9-27351 24' Dia. [7 315] 9-18898 9-27956 9-18899 9-18913 27' Dia. [8 230] 9-18898 9-27956 9-18899 9-18913 30' Dia. [9 144] 9-18898 9-27956 9-18899 9-18913 33' Dia. [10 058] 9-18937 9-27957 9-18938 9-18939 48' Dia. [14 630] 9-18964 9-27959 9-18965 9-18966 9-18967 54' Dia. [16 459] 9-18830-54 9-27985-54 9-18831-54 9-18833-54 9-18834-54 Farm Grain Bin Body Sheet Part Number Charts 42 High Fan Transition Sheets - 115.75 in. [2 940] long Aeration Fan Transition Sheets - 115.75 in. [2 940] long COLOR 14 11 8 dk. green lt. green silver Weight 15' Dia. 18' Dia. 21' Dia. 24' Dia. 27' Dia. 30' Dia. 33' Dia. (pounds) [4 572] [5 485] [6 401] [7 315] [8 230] [9 144] [10 058] 9-39738-15 9-39738-18 9-39738-21 9-39738-24 9-39738-27 9-39738-30 9-39738-33 68.7 111.8 9-39739-15 9-39739-18 9-39739-21 9-39739-24 9-39739-27 9-39739-30 9-39739-33 153.9 48' Dia. 54' Dia. [14 630] [16 459] 9-39738-48 9-39738-54 9-39739-48 9-39739-54 9-39740-48 9-39740-54 MGB1945B BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) GAUGE BROCK® 12'-54' Dia. Farm Grain Bin Construction Manual (Narrow 2.67” Corr.) Parts Listing Parts Listing Part No. 9-14153 9-14155 9-14163 9-14164 9-14165 9-14166 9-14168 9-14170 9-22778 9-22779 Description GRAIN BIN PARTS Base Angle w/ 7/16'' holes 30' [9 144] thru 36' [10 973] dia. Base Angle w/ 7/16'' holes 42' [12 802] and 48' [14 630] dia. Base Angle w/ 3/8'' holes 15' [4 572] dia. Base Angle w/ 3/8'' holes 18' [5 486] dia. Base Angle w/ 3/8'' holes 21' [6 401] dia. Base Angle w/ 3/8'' holes 24' [7 315] thru 27' [8 230] dia. Base Angle w/ 3/8'' holes 30' [9 144] thru 36' [10 973] dia. Base Angle w/ 3/8'' holes 42' [12 802] thru 54' [16 459] dia. Anchor Plate Anchor Bracket 9-12600 39-20010 39-20019 39-20020 39-20022 39-20025 39-20031 39-20037 39-20056 39-20058 39-20072 39-20073 39-20074 39-20079 39-20081 39-20114 39-20120 39-20131 39-20132 39-20139 39-20140 39-20152 39-20205 39-20247 39-20256 39-20296 39-20299 HARDWARE Caulking Bolt, Hex Head #2 5/16 x 3/4'' Gr. 2 Nut, Jam 1/4'' -20 Nut, Hex 5/16'' -18 Nut, Hex 1/2'' -13 Nut, Lock 3/8''-16 Bolt, Anchor Bolt 1/2-13 x 8'' x 2'' (optional part) Bolt, Carriage 1/4-20 x 3/4'' Washer, Heavy 1/2'' Washer, Flat 5/16'' Bolt, Bin Seal 5/16-18 x 3/4'' Gr. 8.2 Bolt, Bin Seal 5/16-18 x 1'' Gr. 8.2 Washer, Curved 12 Gauge - .100'' Washer, 5/16'' Neoprene Nut, Wing 1/4'' Nut, Nex 3/8''-16 Bolt, Eye (closed) 5/16 x 1'' Washer, 10 Gauge, Curved 1 1/16 x 2'' Bolt, Bin Seal 3/8-16 x 1'' Gr. 8.2 Hinge Pin 3'' [76] for Top and Bottom Door Board Hinge Pin 5 1/2'' [140] for Middle Door Board Nut, Flange 5/16 x 11/16'' O.D. Bolt, Bin Seal 3/8-16 x 1 1/4'' Gr. 8.2 Bolt, Eye 1/2-20 x 1 1/2'' Screw, Hex Socket Chamfered Cap 1/2 x 1'' Screw, Hex Socket Cap N/CH 1/2 x 1'' Washer, High Collar Lock 1/2'' 13-26114 13-26114SP 13-26114FR 19-44067 19-44069 19-44069SP 19-44069FR 19-26267 MGB1945B SAFETY DECALS DANGER Decal, Suffocation and Auger (English) DANGER Decal, Suffocation and Auger (Spanish) DANGER Decal, Suffocation and Auger (French) CAUTION Decal WARNING Decal, Unloading (English) WARNING Decal, Unloading (Spanish) WARNING Decal, Unloading (French) WARRANTY REGISTRATION Warranty Registration Kit 43 Different by Design™ BROCK GRAIN SYSTEMS A Division of CTB Inc. P.O. Box 2000 • Milford, Indiana 46542-2000 • U.S.A. Phone (574) 658-4191 • Fax (574) 658-4133 e-mail: brock@brockmfg.com • Internet: http://www.brockmfg.com and 7400 East Thirteenth Street, Kansas City, Missouri 64126 U.S.A. Phone (816) 968-6101 FAX: (816) 968-6272 TLX: 6841105 Printed in the U.S.A. All specifications subject to change without notice. Changes this issue: Some Anchor Bolt information was clarified. Page 13: Anchor Bolt information for 54' 12-Ring Anchor was added. Anchor Bolt quantities were corrected on Page 34. There were miscellaneous corrections and additions. Changes last issue: This Manual was previously Part No. MGB1205H. There were some Body Sheet gauge changes. Recirculating gauges were added. September 2008 MGB1945B