Glass supporting system Systèmes de garde corps vitres

Transcription

Glass supporting system Systèmes de garde corps vitres
Glass supporting system
Systèmes de garde corps vitres

A
LUMINCO, headquartered in Inofyta Viotias, was
ƒƒ Outdoor systems, such as Pergolas, shading systems,
the first company in this sector which, since its es-
canopies, gates, fences and lighting posts, offering in-
tablishment, launched the production of items made of cast
tegrated solutions for the construction of high demand
aluminium in traditional designs.
buildings
After 31 years of experience in the aluminium sector, the
ALUMINCO exports its products to over 60 countries
company has evolved into a vertically integrated aluminium
globally and is always at the forefront of innovative develop-
industry.
ment of products and systems satisfying the most demand-
Its production facilities include integrated processing,
powder coating, assembly, finishing, packaging and storage
units for the products it produces and delivers.
ing clients.
The powder coating process is certified by QUALICOAT
and SEASIDE CLASS (seaside class processing) specifica-
ALUMINCO offers a wide range of aluminium products
tions. Furthermore, ALUMINCO also conforms to the ISO
and systems, architectural and construction solutions,
9001 certified by TUV Austria, for quality management sys-
which include:
tem and the ISO 14001 environmental management system.
ƒƒ A full range of tilt & turn as well as sliding, cold and thermal
break aluminium systems, as well as curtain wall
ƒƒ A variety of designs on aluminium panels for any archi-
All aluminium and railing systems are designed, developed
and tested by our Research & Development department and
are then certified by established institutes and international
tectural or construction requirement, with an emphasis on
organizations, such as the
style, functionality and safety
IFT Rosenheim in Germa-
ƒƒ Safety doors and reinforced doors for main entrances
ny, the Instituto Giordano
suitable for private or commercial buildings. Available in
in Italy, the EKANAL (Greek
traditional or modern designs, in a large variety of patterns
Center of Aluminium Devel-
and colors
opment) in Greece.
Nachweis
Tragfähigkeit absturzsichernder
Verglasungen unter stoßartigen Einwirkungen
Prüfbericht
Nr. 12-001323-PR01
(PB-C07-09-de-01)
aluminium or inox type profiles and glass railing systems
ALUMINCO S.A.
Megali Rahi
32011 Inofita Viotias
Griechenland
Produkt
Brüstung
- F85 TYPE E WITHOUT RAILTOP AND 20mm GLASS
- CRYSTALINE F85 TYPE C WITH 20mm GLASS
- CRYSTALINE F85 TYPE A WITH 16 mm GLASS
F85 TYPE E WITHOUT RAILTOP AND 20mm GLASS:
Glas: ESG 10 mm / 4 x 0,38 PVB / ESG 10 mm
Scheibenabmessung (B x H): 1000 mm x 1257 mm
Glasbefestigung: 2 x F85-150E und 1 x F85-300E
CRYSTALINE F85 TYPE C WITH 20mm GLASS:
Glas: ESG 10 mm / 4 x 0,38 PVB / ESG 10 mm
Scheibenabmessung (B x H): 1000 mm x 1177 mm
Glasbefestigung: 2 x F85-150C und 1 x F85-300C
CRYSTALINE F85 TYPE A WITH 16 mm GLASS:
Glas: ESG 8 mm / 4 x 0,38 PVB / ESG 8 mm
Scheibenabmessung (B x H): 1000 mm x 1177 mm
Glasbefestigung: 2 x F85-150A und 1 x F85-300A
Unten partiell linienförmig gelagert
Bezeichnung
Lagerung
Besonderheiten
Ergebnis
Grundlagen *)
Technische Regeln für die Verwendung von absturzsichernden
Verglasungen (TRAV)
Fassung: 2003-01
Kein Lastabtragender Holm vorhanden
Kantenschutz wird auf das Produkt aufgebracht
Tragfähigkeit absturzsichernder Verglasung
Kategorie A: 900 mm Fallhöhe
ƒƒ Railing systems f or balconies, patios and stairs. In traditional and modern designs, made of cast aluminium,
Auftraggeber
Leistungsrelevante
Produktdetails
Darstellung
Verwendungshinweise
Dieser Prüfbericht dient zur Vorlage bei der obersten Baubehörde zum Nachweis der Eignung
von absturzsichernden Verglasungen im Rahmen der Zustimmung im Einzelfall.
Gültigkeit
Diese Prüfung/Bewertung ermöglicht keine Aussage über weitere
leistungs- /qualitätsbestimmende
Eigenschaften des Produkts.
Veröffentlichungshinweise
ift Rosenheim
19. Oktober 2012
Es gilt das "Merkblatt zur Benutzung von ift-Prüfdokumentationen". Das Deckblatt kann als
Kurzfassung verwendet werden.
Inhalt
Karin Lieb, Dipl.-Ing. (FH)
Prüfstellenleiter
Baustoffe & Halbzeuge
Ve-PB0-1190-de ( 01.03.2012)
4
Andreas Schmidt
Prüfingenieur
Materialprüfung
Der Nachweis umfasst insgesamt
18 Seiten und Anlagen (12 Seiten).
A
LUMINCO, siégeant à Inofyta Viotias (40km d’
n’ est pas «habillé» par ALUMINCO.
Athènes et 70km de l’ aéroport international Elef-
Les produits ALUMINCO sont diffusés dans plus de 60
therios Venizelos) fut la première société en Grèce qui a
pays a travers le monde! Guidés par nos clients et par la
lance la fabrication de produits en aluminium en fond d’ alu
demande du marche, nous nous efforçons de satisfaire les
au design classique.
demandes les plus exigeantes, aussi bien en qualité que en
Avec son expérience de plus de 31 ans, la société a évo-
fonctionnalité.
luée dans une industrie d’ aluminium verticale grâce aux
Notre plant de laquage électrostatique, et procédure de
investissement et développement des sa capacité de pro-
laquage sont bien certifies par QUALICOAT et selon spécifi-
duction.
cations de SEASIDE CLASS.
ALUMINCO offre une vaste gamme de produits et sys-
Le respect d’ ALUMINCO pour l’environnement est bien
tèmes en aluminium, en satisfaisant de demande les plus
prouvé par ISO 14001, et ISO 9001 (norme internationale)
exigeantes, tels que:
émis par l’ organisme TUV d’ Autriche (gestion / manage-
ƒƒ Une gamme complète de Systèmes de menuiserie, ou-
ment de la qualité).
vrant a la française, coulissant, coulissant a lever, mur rideau, en rupture thermique ainsi qu’ en sérié froide.
ƒƒ Une gamme varie de panneaux en aluminium, compatible
avec tout les systèmes de menuiserie, au style contemporain ou classique
ƒƒ Des portes d’ entrée, portes de sécurité, adaptable aux bâtiments prive ou même de commerciaux, grâce aux grand
choix de modèles
ƒƒ Une gamme de systèmes de garde corps, le plus complet
du marche.
ƒƒ Nos systèmes d' ombrage, Pergolas, marquises, clôtures
et portails et éclairage ne laissent pas aucune espace qui
Pour suivre les tendances architecturales fortes, ALUMINCO et son équipe, commence par la conception, le design
et finissent par la mise en œuvre de l’ ensemble de produits
et systèmes.
5

Index
A•line
A10•line
On-floor supporting system
Pose sur dalle
On-floor supporting system
with 10 mm glass
Pose sur dalle
avec de verre de 10 mm
A20•line
Wedge on floor system
Pose sur dalle
avec de profité de sol et une pièce
12 20 28
6
A20u•line
In-floor wedge system
Système encastre en une pièce
de profile
B•line
C2•line
Adjustable system for on-floor
installation
Système réglable, pose sur dalle
On-floor supporting system
Pose sur dalle
34 40 48
C2u•line
D•line
Ds•line
In-floor support system
Système encastré
Fascia mount system
Pose sur nez de dalle
External support with glass
brackets
Pose sur nez de dalle avec des
adaptateurs à verre
56 64 72
Dc•line
External support with fascia
aluminium profile
Pose en applique (nez de dalle)
Dc•line no drill
Evolutionary concept of external
fascia mounting, without any
drilling on the glass panels
Conception révolutionnaire sans
percer la verre
E•line
Heavy duty on floor system
Système de haute exigence
78 84 90
L•line
Top handrails & brackets
Main courante et fixations
Glasses
Verre
On-floor supporting system
Pose sur dalle
98 114 118
Accessories
Accessoires
120
7
General information
Aluminium
No other material can match the characteristics of aluminum. Light weight but
strong at the same time, resisting to the most severe weather conditions, due
to the application of oxide layer that protects the metal from corrosion. This
layer is further strengthened by anodisation, providing even greater weather
resistance. Furthermore, it is the most environmental friendly metal, as it is
fully recyclable and non-toxic.
Aluminium has a unique combination of attractive properties:
ƒƒ
ƒƒ
ƒƒ
ƒƒ
ƒƒ
ƒƒ
Low weight
High strength
Superior malleability
Easy machining
Excellent corrosion resistance
Easy to mill, drill, cut, punch, bend, weld, bond, tape.
Cleaning: Aluminium products can be cleaned with warm water and soap.
Some 75 percent of all aluminium ever produced is still in use! Aluminium
can be reused for the same purposes over and over again. Unlike many
other materials, aluminium does not lose its unique properties. Furthermore,
the energy needed to produce secondary aluminium is only 5 percent of
the original energy input.
Use of glass panels in
Crystalline installations
A wide range of glass panels can be integrated
with Crystalline system, in various thicknesses
and characteristics according to specifications.
There are two main categories according
to EN12543 and EN12600 specified by the
European Union concerning the thermal Toughened Glass
treatment of the glass.
Thermally Toughened glass
More specifically, EN12543 specifies the use of
tempered and laminated glass with the insert of
PVB membranes .This type of glass panels have
the following qualities:
According to European Normes (EN 12600) the minimum number of films
required is two, however ALUMINCO recommends the use of glass with four
PVB films for maximal security.
Τypes of securit glasses
The most common type Triplex glass consists of
the combination of Heat Strengthened Glass –
PVB – Heat Strengthened Glass. The result of a
Heat Strengthened glass panel will resist two times
stronger than ordinary glass, where a unified static
force has been applied (EN 12543), to one of the
same thickness.
The second type of Triplex glass, and the one which
meets the safety criteria is Thermally Toughened
Glass, and its combination with PVB, known as
toughened glass. Toughened Glass is manufactured
by subjecting the finished glass size to a heating and
cooling treatment which set up high compressive
stresses at the surface, and balancing tensile
stresses in the center of the glass, thus increasing its strength. The result is a
glass that is 5 times stronger than ordinary glass.
Heat strengthened glass is produced by a similar process to toughened glass,
however, the strength developed is about half that of toughened glass, and its
breakage resembles that of annealed glass.
ALUMINCO strongly recommends the use of Heat Strengthened Glass with
the installation of any type of Crystalline system.
Colors
a) In case of breakage, they do not break in
large and sharp pieces.
b) Even in case of such breakage , the broken
Laminated Glass
glass pieces remain attached on the PVB TRIPLEX glass with
surface without putting in danger the safety PVB membrane
of nearby persons. The fabrication of these
tempered and laminated glass panels is being
carried out by thermal treatment of ordinary glass which is afterwards
sandwiched together with the PVB membranes to give the various grades
and thickness of laminated glass panels.
In the following pictures show the different types of breakage:
a) Tempered and laminated glass, and,
Aluminco provides you with a choice of three standard colors for
aluminium profiles and accessories of Crystalline systems: A-001
Matt & A-432 Gloss anodizing colors and metallic powder
coating color Anodic 420.
By defining every architectural or professional desire, Crystalline
systems are also offered in a wide range of quality colors upon
request: gloss and matt finishes, metallic and anodizing colors,
RAL, super durable powder coating colors and sublimation wood
effects.
ANODIZING
A-001 Matt & A-432 Gloss
METALLIC
Anodic 420
ALUMINCO Certifications
Customer satisfaction and quality assurance are both high on our list of
properties. We strive, together with our suppliers, to guarantee permanent
high quality.
b) Ordinary tempered glass.
PVB films
ƒƒ Quality Management System Certification
(According to the international EN ISO 9001:2008)
ƒƒ Environmental Management System Certification
(According to the international EN ISO 14001:2004)
ƒƒ Certificate of Compliance QUALICOAT
(Certificate of Quality Painting Aluminium Profiles)
ƒƒ Certificate of quality QUALANOD
(Certificate of quality of anodized aluminum profiles)
The common characteristics amongst the two
categories mentioned previously, are the use of the
PVB interlayer films.
The film is of a tough yet pliable material known as
polyvinyl butyral (PVB), placed in layers between the
glass.
Rollers press the layers together to expel any air
pockets. The glass is then heated to 70oC in a
pressurized oil bath to permanently bond all layers
together. Typically the thickness of each PVB film
is 0,38 mm, additional layers of glass and PVB film
Apart from the different thickness of glass and PVB, a wide range of colored
PVB , for example grey, blue green or yellow is available, offering a particular
esthetique to modern buildings.
Even in the event that the glass breaks, the two layers are held together by
the PVB, allowing the sheet as a whole to bend and absorb the impact. This
characteristic is especially important for places where safety or security are
paramount.
Unless stated otherwise in our catalogue, all of Crystalline types are brushed
and anodized, make them ideal for both indoor and outdoor use.
8
increase the strength of the material. Applying two interlayers of film, the
thickness becomes 0,78 mm, with three at 1,14 mm and so on.
Sustainability
Glass
PVB film
Aluminco makes every effort to reduce any negative environmental impacts
resulting from production processes. This means that Aluminco is passionately
interested in sustainability, by being at the forefront in the development of
energy saving, recycling and waste management and sustainable products.
Informations générales
Aluminium
Il est difficile de trouver un autre matériel avec tells caractéristiques que
aluminium. Léger mais robuste en même temps, résistant au conditions
climatiques les plus sévères, grâce al’ application d’ une couche fine d’ oxyde
qui l’ en protège de corrosion. Cette couche devient encore plus forte par
le procédure d’ anodisation pour une protection contre la corrosion le plus
efficace.
A ne pas oublier que l’ aluminium est totalement recyclable et respectueux
de l’ environnement.
Ses caractéristiques uniques
ƒƒ
ƒƒ
ƒƒ
ƒƒ
ƒƒ
ƒƒ
Léger & robuste
Non toxique
Propriété mécanique excellent
Usinage facile
Résistant au corrosion
Rapport prix – qualité excellent
Pour être en règle avec les European Standards (EN 12600), il faut au moins
utiliser 2 membranes PVB entre deux parties de vitrage. Pour utiliser nos
système Crystalline, ALUMINCO recommande de toujours regarder situation
par situation et de ne jamais hésiter a mettre un PVB en trop pour accroître
la sécurité.
Typologie de verre trempe et
feuilleté
Le verre, matériaux de construction, est un moyen
d’ ajouter de style et élégance, mais ce qui est
le plus important c’ est la sécurité de personnes.
Dernièrement, le verre a utilise avec les garde
corps vitres, sont de verre trempe et feuilleté.
Sauf autrement indique, la finition standard de toutes profiles du système
Crystalline sont disponible an aluminium anodise et brosse en teint d’ inox.
Saviez vous que 75 pour cent de produits fabrique n aluminium, sont toujours
utilisables. Aluminium peut être recycle pour plusieurs fois.
Ses caractéristiques mécaniques ne sont pas déformés comme dans des
autres cas. L’ énergie utilise pour recycle l’ aluminium est a 5% par rapport a
son production primaire.
Généralités sur les garde
corps Crystalline
Le verre feuilleté est un assemblage de feuilles de
verres et d’ intercalaires de nature plastique. Les
intercalaires peuvent se présenter sous forme de
film, généralement (Poly-Vinyle-Butyral ).
Ses caractéristiques, ils conservent les propriétés lumineuses et énergétiques,
des produits de base. Une fois trempes, ils ne peuvent plus être découpés
ni façonnés.
Le verre feuilleté pour bâtiment fait l’objet de la norme EN ISO 12543.
Les couleurs
Le système Crystalline offre des solutions
polyvalentes ou des différent dimensions de
vitrage, selon le type et Avis Technique sont
adaptes. Pour des raisons liées a la sécurité
des personnes, ces éléments verriers doivent
conformer aux Normes Européens (EN12543 Toughened Glass
&EN12600) qui spécifie le traitement thermique Thermally Toughened glass
par un processus de trempe (refroidissement
rapide).
Plus précisément, la gamme de systèmes
Crystalline s’ installe avec de verre trempe et
feuilleté ou lamine de son nom technique,
constitue d’ au moins deux feuilletés de verre
séparées par de films intercalaires (PVB).
Aluminco vous offre un choix de trois couleurs standard pour les
profilés en aluminium et accessoires de systèmes Crystallins:
brillant et mat couleurs d'anodisation et de la couleur métallique
en poudre et couleur anodique 420.
En définissant chaque désir architectural ou professionnel, les
systems Crystallins sont également proposés dans une large
gamme de couleurs de qualité sur demande: brillant et mat
finitions, métalliques et anodisation couleurs RAL, couleurs en
poudre ultra durables et les effets de bois de sublimation.
9
ANODIZING
A-001 Matt & A-432 Gloss
METALLIC
Anodic 420
ALUMINCO Certifications
La satisfaction du client et l'assurance qualité sont au sommet de notre liste
de propriétés. Nous nous efforçons, en collaboration avec nos fournisseurs,
pour garantir une haute qualité permanente.
C’ est grâce aux ces propriétés mécaniques Laminated Glass
TRIPLEX glass with
et résistance au choc, que même au cas de PVB membrane
blessure, le verre ne présent pas aucune risque
lorsque les pièces casses sont retenue par le
film PVB.
La fabrication de verres trempes et feuilletés est fait par un traitement
thermique qui rendent le verres ces qualités de sécurité.
Les photos ci-dessous montrent les différent types de brisure :
a) Verre trempe
b) Verre trempe et feuilleté
ƒƒ Certification Système de Management Qualité
(Selon l'international EN ISO 9001: 2008)
ƒƒ Environmental Management System Certification
(Selon l'international EN ISO 14001: 2004)
ƒƒ Certificat de Conformité QUALICOAT
(Certificat de qualité Peinture Profils Aluminium)
ƒƒ Certificat de qualité QUALANOD
(Certificat de qualité des profils en aluminium anodisé)
Durabilité
Aluminco fait tous les efforts pour réduire les impacts environnementaux
négatifs résultant des processus de production. Cela signifie que Aluminco
est passionné par le développement durable, en étant à l'avant-garde dans
le développement de l'économie d'énergie, recyclage et gestion des déchets
et des produits durables.
PVB films
Le membrane PVB est un intercalaire qui retient les
fragments de verre en cas de casse due a des heurts
accidentels, le vitrage reste en place, si encadre et il
n’ y a pas de chute de morceaux dangereux.
L’ épaisseur d’ un membrane PVB est de 0,38 mm,
en pratique on utilise plusieurs membranes de cette
épaisseur afin d’ accroître la durabilité et l’ élasticité
du vitrage feuilleté. En ajoutant deux membranes l’
épaisseur devient 0,76 mm en ajoutant un troisième
cela devient 1,14 mm etc… le PVB est disponible
dans une gamme de couleurs allant du transparent,
le gris le jaune et beaucoup d’ autres combinaisons qui permettent de réaliser
une balustre en harmonie avec l’ esthétique de résidence.
Verre
PVB film
Description of Rail Tests
Public Function – Stadiums – 1,5 KN-3 KN (3 KN/m): C2, C3, D, E
The object of the test is to verify the behaviour of the balustrade under:
0.5 L
Static Loads
RAIL BOTTOM VIEW
HANDRAIL STATIC LOADING
Horizontal outwardly directed
static service and safety loads
(linearly distributed and point
horizontal loads). The load is
0.4 L
0.4 L
F/4
F/2
F/4
applied at the central point of
handrail, and then at two symL
metrical points, a quarter and
three quarters of the way along the handrail, whilst deformation is measured
halfway along the overall length.
Public spaces and stadiums, where lot of people may assemble in small space,
require robust balustrades. Glass thickness and heavy profiles provide safety
under heavy loads. The glass Balustrade must be able to withstand up to 3 KN
per linear meter.
Type of
occupancy
Description
Example of use
A1
All areas within or serving
exclusively a single occupancy
dwelling including stairs, landing
etc., but excluding external
balconies and edges of trafficable
roofs where the level is greater than
three (3) meters above the adjoining
ground level.
Internal or external balconies where
the level is more than one (1) meter,
but less than three (3) meters, above
the adjoining ground level for single
occupancy dwelling up to 2 storeys.
A2
All other areas of residential
buildings except those defined
in A1.
Dynamic Loads
RAIL DYNAMIC
LOADING TEST
10
It is the impact test using a suspended soft body of 50 kg, comprising an
Aluminium solid tube, along with two
tyres, or another bag full of small Aluminium spheres, always totalling
weight of 50 kg as soft body load. Impact points on glass panel are shown
on following photos.
50 kgr
Drop Height (H), for soft body mass
H
50 kg = 0,5 KN :
50 kgr
K
300 mm = 0,30 m -> Housing / Residential Category
450 mm = 0,45 m -> Offices / ComK/2
mercial Category
700 mm = 0,70 m -> Public / Mall
Category
L
stand-off from ground
900 mm = 0,90 m -> Public / Mall
Category
Max. Permissible Horizontal Deflection = K/300,
Max. Rail Height = K = 1200 mm
Using, Max. Permissible Horizontal Deflection = 4 mm = 0,004 m:
During impact test, no falling glass fragments may become detached that could
cause personal injury, and also the filling element of the rail must not separate
from the structure of the balustrade, and the glass must continue to exercise
its function under the application of a punctual load of 200 N=20 kg for 30
seconds. The impact body must not pass through the balustrade upon impact.
4
3
2
1
Impact Points on glass panel
Impact
Velocity
(m/sec)
SQRT
(2gH)
Impact Load
Impact Dynamic
(kg) caused
Energy
by soft body
Impact Time (Joules=Nm)
50 kg = 0,5 KN (milliseconds)
0,5KN x
onto the
Drop Height =
Glass Panel
mgH
Category for
Impact Test
Certification
Drop
Height
(m)
Housing,
Residential
0,30
2,43
3690
1,6
150
Office,
Commercial
0,45
3,00
5625
1,3
225
Public,
Mall
0,70
3,70
8556
1,0
350
Public,
Mall
0,90
4,20
11025
0,96
450
Rail Test Categories: Housing / Residential Function – 0,5 KN (0,5
KN/m): A1, A2, B1
Relatively light constructions can be used for applications in homes. The glass
balustrade must be able to withstand 0,5 KN per linear meter.
Office Function – 1 KN (1 KN/m): A2, B1, B2, C1
Glass balustrades in offices require the use of heavier materials. The glass must
be thicker and the profiles must obviously be adapted accordingly. The glass
balustrade must be able to withstand 1 KN per linear meter.
B1
C1
C2
C3, C4
D
E
Office, work and storage areas
not covered elsewhere, with light,
non-public pedestrian traffic
routes, including light access stairs,
gangways and areas used for
maintenance purposes.
Areas where people may
congregate without obstacles for
moving people, but not susceptible
to overcrowding, including fire
escape portions of residential
buildings.
Areas where people mayn
congregate with table and fixed
seating but not susceptible to
overcrowding, including fire escape
portions of all buildings other than
residential.
Areas where people may
congregate and are susceptible to
overcrowding.
All retail areas excluding areas
susceptible to overcrowding.
Vehicular and traffic areas
External balconies of multi-storey
buildings where the level of the
balcony is more than three (3) meters
above the adjoining ground level.
A single office at mezzanine level of a
small showroom, maintenance areas
and the like.
Stairs, landings, corridors, ramps,
external balconies, edges of roofs,
footways and pavements and the like
within building cartilage adjacent to
basement or sunken areas.
Restaurants, bars and the like.
Theatres, stadiums, cinemas,
discotheques, auditoriums, assemble
areas and bars and the like.
Public areas of banks shopping
centers and the like.
Pedestrian areas in car parks
including stairs, landings and the like
except areas where there is a danger
of dynamic vehicle impact.
Table 2.1 Type of occupancy
Type of
occupancy
(*1)
Uniformly
distributed load
(KN/m)
(*2), (*3)
Point load
applied to top
rail (kN)
(*2), (*3), (*4)
Uniformly
distributed load
applied to the infill
(KPa) (*2)
Point load
applied to part
of the infill (KN)
(*2), (*4)
.6
.5
.25
A1, B1
.4
A2, B2, C1
.75
1
.5
C2, D, E
1.5
1.5
1.5
C3, C4
3
1.5
1.5
Table 2.2 Design live loads
(*1) The type of occupacy for building is tabulated in the table 2.1
(*2) The applied load may act inward, outward or downward
(*3) The applied loads act on the hand rail
(*4) Point and uniform loads are not concurrent
Institutes for Rail Load Tests / Rail Test Norms
Instituto Giordano S.P.A- Italy:
Test Norm NFP01-013: 1988 – Static Loading of Rails with Rail top
Test Norm NFP08-301: 1991 – Dynamic Loading of Glass Rails for Housing Function
Test Norm UNI-10807: 1999 – Dynamic Loading of Glass Rails for Office Function
IFT Rosenheim- Germany:
Test Norm TRAV: 2003-01 – Dynamic Loading of Glass Rails
BBRI (CAR INSTITUTE BELGIUM):
Test Norm NBN-B03-004: 2010 - Static Loading & Dynamic Loading of Balustrades of Buildings
Test Norm NBN / DTD-B03-004: 2015 - Static Loading & Dynamic Loading of
Balustrades of Buildings
FTL (FLORIDA):
Test Norm FBC section 1607.7.1.1-1607.7.1.2: Static Loading – Concentrated
Load Balustrade Test
Test Norm ANSI Z971: Dynamic Loading of Balustrades of Buildings – Drop Test
Test Norm ASTM- E1996: Dynamic Missile Impact Test – Glass Balustrades
Description de test du garde-corps
0.5 L
Le but du test est de vérifier le
comportement de la balustrade
sous:
RAIL BOTTOM VIEW
HANDRAIL STATIC LOADING
Les charges statiques
La fonction de sécurité d'essai
0.4 L
0.4 L
F/4
F/2
F/4
pour le main courante. Mettre en
L
œuvre la charge horizontale dirigées vers l'extérieur (linéairement
répartis et les charges horizontales punctal). La charge est appliquée au point central de la main courante, puis en deux points symétriques, un quart et trois quarts
du chemin le long de la main courante, tandis que la déformation est mesurée à
mi-chemin le long de la longueur totale.
Type of
occupancy
Description
Example of use
A1
Toutes les régions à l'intérieur, ou de
servir exclusivement un logement
en occupation simple, y compris les
escaliers, l'atterrissage, etc., mais à
l'exclusion des balcons et les bords
des toits circulables externes dont le
niveau est supérieur à trois (3) mètres
au-dessus du niveau du sol attenant.
Balcons internes ou externes dont le
niveau est plus d'un (1) mètre, mais
moins de trois (3) mètres, au-dessus
du niveau du sol attenant pour une
occupation simple habitation jusqu'à
2 étages.
A2
Toutes les autres zones de
bâtiments résidentiels, sauf ceux
qui sont définis dans A1.
B1
Charges Dynamiques
Il est le test d'impact en utilisant un corps
mou suspendu de 50 kg, comprenant un
tube solide en aluminium, ainsi que deux
pneus, ou un autre sac plein de petites bullets d'aluminium, toujours un total de poids
de 50 kg aussi doux de charge du corps.
les points d'impact sur le panneau de verre
sont présentés sur les photos suivantes.
Hauteur de chute (H), pour la masse
50 kgr
de corps mou 50 kg = 0,5 KN :
H
300 mm = 0,30 m -> Logement /
50 kgr
K
Résidentiel Catégorie
450 mm = 0,45 m -> Bureaux / CenK/2
tre Commerciale
700 mm = 0,70 m -> Publique / Mall
Catégorie
L
stand-off from ground
900 mm = 0,90 m -> Publique / Mall
Catégorie
Max. Adm Déviation Horizontale
= K/300,
Max. garde- corps Hauteur = K = 1200 mm
Utilisation, Max. admissible déviation horizontale = 4 mm = 0,004 m:
Au cours du test d'impact, pas de fragments de verre qui tombent peuvent se
détacher qui pourrait causer des blessures, ainsi que l'élément de remplissage
du rail ne doit pas se séparer de la structure de la balustrade, et le verre doit continuer à exercer sa fonction dans l'application d'une ponctuelle charge de 200 N
= 20 kg pendant 30 secondes. Le corps d'impact ne doit pas passer à travers la
balustrade lors de l'impact.
RAIL DYNAMIC
LOADING TEST
4
3
Hauteur
(m)
Impact
(m/sec)
SQRT
(2gH)
l'impact de
charge (kg) a
Impact de
provoqué
temps
50 kg = 0,5 KN (milliseconds)
par corps mou
C3, C4
D
E
Vehicular and traffic areas
Les escaliers, les débarquements,
les couloirs, les rampes, les balcons
extérieurs, les bords des toits, des
trottoirs et des chaussées et autres dans
le bâtiment du cartilage adjacent au
sous-sol ou les zones en contrebas.
Restaurants, bars et autres.
Theatres, stadiums, cinemas,
discotheques, auditoriums, assemble
areas and bars and the like.
Les parties communes de banques
centres commerciaux et autres.
Les zones avec véhicules et les
zones piétonnes dans les parcs de
stationnement, y compris les escaliers,
les paliers, etc., sauf les zones où il y a un
risque d'impact dynamique du véhicule.
Table 2.1 Type d'occupation
Type
d'occupation
(*1)
Charge répartie
uniformément
appliquée au
remplissage(KN/m)
(*2), (*3)
Charge point
appliquée à
une partie du
remplissage(kN)
(*2), (*3), (*4)
Charge répartie
uniformément
appliquée au
remplissage
(KPa) (*2)
Point load
applied to part
of the infill (KN)
(*2), (*4)
.6
.5
.25
A1, B1
.4
A2, B2, C1
.75
1
.5
C2, D, E
1.5
1.5
1.5
C3, C4
3
1.5
1.5
Table 2.2 Design live loads
(*1) Le type d'occupation pour la construction est sous forme de tableau dans le tableau 2.1
(*2) Charge point appliquée à une partie du remplissage (KN)
(*3) Charge point appliquée à main courante (kN)
(*4) Charge répartie uniformément appliquée au remplissage (KPa)
Balustrades en verre dans les bureaux nécessitent l'utilisation de matériaux plus lourds. Le
verre doit être plus épais et les profils doit évidemment être adaptée en conséquence. La
balustrade en verre doit être capable de résister à une 1 KN par mètre linéaire.
Impact Points on glass panel
Catégorie de
certification
Impact Test
Tomber
C2
Un bureau unique au niveau de
la mezzanine d'une petite salle
d'exposition, les zones d'entretien
et autres.
Fonction de bureau - 1 KN (1 KN / m): A2, B1, B2, C1
2
1
C1
Bureau, le travail et les zones de
stockage non couverts ailleurs, avec
des voies de circulation de lumière,
piéton non-public, y compris l'accès
à la lumière des escaliers, des
passerelles et des zones utilisées à
des fins de maintenance.
Les zones où les gens peuvent se
rassembler sans obstacles pour le
déplacement des personnes, mais pas
sensibles à la surpopulation, y compris
des parties d'évacuation d'incendie de
bâtiments résidentiels.
Les zones où les gens se
rassemblent avec table et sièges
fixes, mais pas sensibles à la
surpopulation, y compris des parties
de sortie de secours de tous les
bâtiments autres que résidentiels.
Restaurants, bars et autres.
les zones où les gens peuvent se
rassembler et sont sensibles à la
surpopulation.
Toutes les zones de détail hors des
zones sensibles à la surpopulation.
balcons extérieurs de bâtiments
à plusieurs étages où le niveau du
balcon est plus de trois (3) mètres audessus du niveau du sol adjacent.
Impact
dynamique
Énergie
(Joules=Nm)
0,5KN x
Hauteur de
chute = mgH
Logement,
Résidentiel
0,30
2,43
3690
1,6
150
Bureau,
Commercial
0,45
3,00
5625
1,3
225
Public,
Centre
commercial
0,70
3,70
8556
1,0
350
Public,
Centre
commercial
0,90
4,20
11025
0,96
450
Essai du produit fini Catégories: Logement / Fonction Résidentiel - 0,5
KN (0,5 KN / m): A1, A2, B1
Relativement constructions légères peuvent être utilisées pour des applications
dans les maisons. La balustrade en verre doit être capable de résister à 0,5 KN
par mètre linéaire.
Fonction publique - Stades - 1,5 KN-3 ON (3 KN / m): C2, C3, D, E
Des espaces publics et des stades, où beaucoup de gens peuvent se réunir dans
un petit espace, nécessitent des balustrades robustes. L'épaisseur du verre et
des profils lourds offrent une sécurité sous de lourdes charges. La balustrade en
verre doit être capable de résister jusqu'à 3 kN par mètre linéaire.
Institutes for Rail Load Tests / Rail Test Norms
Instituto Giordano S.P.A- Italy:
Test de la norme NF P 01-013 normes: 1988 - statique chargement de la main courante
Test Norm NFP08-301: 1991 – Test de la Normfonction de logement
Test de la norme UNI-10807: 1999 - Chargement dynamique de verre du garde-corps pour la fonction de bureau
IFT Rosenheim- Germany:
Test Norm TRAV: 2003-01 – Chargement dynamique de verre du garde-corps
BBRI (INSTITUT BELGIQUE):
Test Norm NBN-B03-004: 2010 - Chargement statique et dynamique Chargement de balustrades de bâtiments
Test Norm NBN / DTD-B03-004: 2015 - Chargement statique et dynamique Chargement de balustrades de bâtiments
FTL (FLORIDA):
Test Norm FBC section 1607.7.1.1-1607.7.1.2: Chargement statique - Charge concentrée Balustrade test
Test Norm ANSI Z971: alimentation hors chargement Valystrades offs Vyildings - Méthodes d'essai
Test Norm ASTM- E1996: Force de Missile Impact test - Verre balustrades
11
Info
C
C
ER
R
T I F I É PA
C
TIFIED B
ER
ER
Y
12
C
Y
A line
•
TIFIED B
ER
R
T I F I É PA
On-floor glass supporting system
T
he supporting brackets, in hard aluminium
alloy, are installed on fully finished floor,
ceramic tile, marble or on a balcony parapet.
Glass panels of 88.4 thickness / 17.52mm
and maximum height of 1200mm, are
anchored with bolts which can easily be
removed in case of need without any damage
to the floor or system itself. The brackets are
covered by the oval shape fascia profiles in
anodized finish as well as many other shades
of powder coating.
It is an ideal solution for balconies, stairs
and building enclosures for high architectural
standards, offering an impressive and
functional result with no view limit.
Advantages
ƒƒ Elegant line
ƒƒ Maximum security
ƒƒ Uninterrupted view
ƒƒ Free of maintenance
ƒƒ Patented system
ƒƒ Compliance with UNI EN 10807 & NFP01-013
ƒƒ Optional use of top handrail
ƒƒ Wide choice of colors : RAL, Sable &
anodized
Système de base apparente supportant
le vitrage (pose à la française)
I
l s’ agit de système de garde–corps en verre
solidarises au gros œuvre «en pied», fixes en
dalle.
Type A peut être utilisé dans des espaces
publics ou prives tant a l’ intérieur qu’ a l’
extérieur.
Le montage comporte les vitrage de 88,4
épaisseur de 17,52 mm et hauteur a 1200
mm, qui sont fixe par serrage et fini avec les
profiles d’ habillage.
C’est un système idéal pour des terrasses, des
rampes, des passerelles et des clôtures de
bâtiments de haut standard. Il offre un résultat
impressionnant et fonctionnel, ne limitant pas
la vue.
Avantages
ƒƒ Elégant
ƒƒ Réponds aux critères de sécurité
ƒƒ Vue illimite
ƒƒ Pas d’ entretien
ƒƒ Système breveté
ƒƒ Selon Avis Technique UNI EN 10807 & NF
P01-013
ƒƒ Option de main courante
ƒƒ Choix de coloris – RAL, Sable, anodize &
teint de bois
13
Info
14
A•line
A timeless beauty
where design
and functionality
flow together
harmoniously!
15
A•line
A•line
On-floor glass supporting system
Fixing point / Detail de fixation
F85-150Α
F85-300Α
Ø12
30
30
max. 17,52
90
150
DIN 934 Μ10
(Included in the supporting base)
120
Ø12
ΕΒ912-1070
DIN 912 Μ10x70
Tightening torque 40 Nm
Allen No.8
82,4
Μ10x40
(Included in the supporting base)
Drill 16 mm
16
Specifications
techniques
88
30
Technical
specifications
120
ΕΒ01Μ-1040
300
41
30
102,5
DIN 912 Μ10x55
(Included in the supporting base)
Tightening torque 22 Nm
Allen No.8
Glass Types
16 mm
82,4
8.8.2
8.8.4
F85-150Α
F85-416
EB7982-4219I
F85-1K1
DIN 7982 4,2x19
Cross bit ΡΗ2
Balustrade Type
Tempered Glass Panel
Height of Balustrade
Static Loading Category
(Horizontal Loads)
Crystalline-A
8.8.4 mm
1100 mm
Residential and Office
buildings, without wind load
Crystalline-A
8.8.4 mm
1200 mm
Dynamic Loading Category
(Impact Test)
Residential and
Office buildings
A•line
Système de base apparente supportant le vitrage (pose à la française)
Supporting base assembly / Installation
Standard supporting base type Α assembly for glasses with a length of 1000 mm
1000
mm
0 mm
10~2
1000
mm
L
L
L
L
m
150 m
m
150 m
m
300 m
m
150 m
m
150 m
17
Technical
specifications
Specifications
techniques
Recommended number of bases / m
8 mm+4PVB+8 mm (88,4)
Glass height
Handrail
No. of bases / m
L
-
3
275 mm
600 mm
F85-200
2
700 mm
1000 mm
1100 mm
1200 mm
F85-201
2
700 mm
-
3
275 mm
F85-200
3
275 mm
F85-201
3
275 mm
-
4
133 mm
F85-200
3
275 mm
F85-201
3
275 mm
-
5
62,5 mm
F85-200
4
133 mm
F85-201
4
133 mm
A•line
On-floor glass supporting system
Installation step by step / Étapes d’ instalation
1
2
3
4
5
6
18
Technical
specifications
Specifications
techniques
A•line
Système de base apparente supportant le vitrage (pose à la française)
Glass supporting bases / Base supportant le vitrage
The supporting bases include tightening screws and pressure gaskets.
Glass base
Code
Glass base
F85-150Α
Package
12 pcs
Code
F85-300Α
Package
6 pcs
19
Technical
specifications
Specifications
techniques
35,7
100,3
100,3
100,3
Profiles & accessories / Profiles & accessoires
88,2
Base cover
88,2
Side cap
Code
F85-1K1
Code
Weight
550gr/m
Package
Length
6m
F85-416
20 pcs
Code
Package
Side cap (Optional)
F85-416L
(8.8.4)
20 pcs
20
Info
C
C
ER
Y
A10 line
•
TIFIED B
ER
R
T I F I É PA
On floor support system with 10 mm glass
L
ight in weight but safe for residential and
light-weight commercial use, this wedge
system is designed to be installed on a finished
floor, with a laminated glass of 55,2 and
thickness of 10,76 mm.
Suitable for the interior as well as exterior
balconies, terraces and swimming pools.
Easy and quick to align, the glass panels are
secured with gaskets and bolts, supplied by
the manufacturer.
Maximum height at 100 cm is recommended
and use of top handrail is essential.
Advantages
The perfect choice for private or light
commercial use, with impressive simplicity and
elegance.
ƒƒ Attractive slim lines
ƒƒ Affordable quality for 10 mm glass
ƒƒ No maintenance required
ƒƒ Patented system
ƒƒ Compliance by TRAV specifications
ƒƒ Quick installation
Pose sur dalle avec de verre de 10 mm
P
our gagner du temps et de l’ argent,
choisissez le type A10!
Le profil de sol, prêt a l’ emploi, c’ est à
dire incluant les gâches et visserie, donne
une installation rapide et facile. La solution
économique pour des lieux publics et privés.
Le verre est fixe par serrage, aucune
perçage sur le vitre n’est requis.
Avantages
ƒƒ Élégant et transparent
ƒƒ Economique
ƒƒ Système breveté
ƒƒ Léger et facile a monter.
ƒƒ Spécifications selon TRAV (allemands )
21
Info
A10•line
22
A10•line
The perfect fit
for attractive and
affordable slim
lines!
23
A10•line
A10•line
On floor support system with 10 mm glass
Glass section A10
Min. 10 mm
Max. 10,76 mm
max. 10,76
D7504-N4825
72,4
DIN 7504Ν 4,8x25
Cross bit ΡΗ2
16,2
ΕΒ912-1070
DIN 912 Μ10x70
Tightening torque 40 Nm
Allen No.8
EBM-75112G
TORX 7,5x112
Drill 6 mm
24
Technical
specifications
Specifications
techniques
45,7
F85-404
F85-202
(Required)
EB7982-4219I
DIN 7982 4,2x19
Cross bit ΡΗ2
F85-904
F85-444
4438
EB7982-4219I
DIN 7982 4,2x19
Cross bit ΡΗ2
F85-411
EA420-443M
Balustrade Type
Tempered Glass Panel
Height of Balustrade
Static Loading Category
(Horizontal Loads)
Dynamic Loading Category
(Impact Test)
Crystalline-A10
5+2PVB+5 mm
1000 mm
(Only with use of rail top)
Residential function,
without wind load
Residential function
A10•line
Pose sur dalle avec de verre de 10 mm
Supporting base assembly / Installation
Standard supporting base type Α10 assembly for glasses with a length of 1000 mm
m
000 m
Max.1
m
000 m
Max.1
25
Technical
specifications
Max. 1000 mm
Specifications
techniques
ATTENTION!
System specifications
a) maximum glass high 1000 mm
b) to be installed with hand rail F85-202
c) indispensable use of bolts per meter
ATTENTION!
Spécification du Système
a) hauteur de verre maximale de 1000 mm
b) utilisation obligatoire de main courante F85-202
c) installation sur dalle avec 4 vis par mètre
A10•line
On floor support system with 10 mm glass
Installation step by step / Étapes d’ instalation
max.
250 m
m
1
2
3
4
5
6
26
Technical
specifications
Specifications
techniques
A10•line
Pose sur dalle avec de verre de 10 mm
72,4
Glass supporting base / Base de support
45,7
Base profile
Code
F85-904
Weight
1796gr/m
Length
6m
Profiles & accessories / Profiles & accessoires
27
Ø50
Technical
specifications
Handrail profile
Side cap
Code
F85-202
Code
Weight
721 gr/m
Package
Length
6m
Hole covering cap
F85-444
20 pcs
Gaskets / Joints
4
11
13,1
7,3
F85-903
(EA410-420M)
Base gasket
Length
Ø13
46,1
12
Code
49
72,8
Specifications
techniques
Handrail gasket
EA420-443M
150 m
Code
Length
EA410-420M
350 m
Code
Package
PVC sheet 1 mm
4438
Code
F85-411
50 pcs (blister)
Color
White
24 pcs (blister)
Length
2m
A20 line
•
28
Info
Wedge on floor system
Pose sur dalle avec de profile
de sol en une pièce
T
A
Advantages
Avantages
his new wedge system is totally frameless, without any intervention of columns
or additional support and ensures crystal clear
view and unique feeling of freedom.
ƒƒ One-piece floor profile for quick installation
ƒƒ Optional in- floor installation
ƒƒ Color choice – RAL, Sable & anodized
ƒƒ Minimal design
ƒƒ Limitless transparency and view
ƒƒ Optional use of handrail
vec ce système, le design rencontre
la sécurité, grâce au profile de base
d’une seule pièce et du verre sans aucun
intermédiaire. Fixation sur dalle avec calages et
joints PVC.
ƒƒ Support d’ un seul block
ƒƒ Option d’ installation encastre
ƒƒ Choix de coloris – RAL, Samble & anodize
ƒƒ Design minimal
ƒƒ Vue transparente
ƒƒ Option de main courante
An ultra-modern
line offers a
fantastic look!
29
Info
A20•line
Wedge on floor system
max. 17,52
Glass section A20
F85-456
16 mm
Min. 16,76 mm
9,6
110
Max. 17,52 mm
EBM-75112G
TORX 7,5x112
Drill 6 mm
30
Technical
specifications
Specifications
techniques
70
F85-455
F85-456
F85-460
F85-450
F85-1K50
EB7982-4219I
DIN 7982 4,2x19
Cross bit ΡΗ2
Balustrade Type
Tempered Glass Panel
Height of Balustrade
Static Loading Category
(Horizontal Loads)
Dynamic Loading Category
(Impact Test)
Crystalline-A20
8.8.2 mm
1200 mm
Residential function,
without wind load
Residential function
A20•line
Pose sur dalle avec de profile de sol en une pièce
Supporting base assembly / Installation
Standard supporting base type A20 assembly for glasses with a length of 1000 mm
1000
Use of F85D-130 is optional
Utilization de F85D-130 en option
1000
mm
mm
m
50 m
m
50 m
m
L
50 m
m
50 m
L
L
31
Technical
specifications
Specifications
techniques
m
20 m
Recommended number of bases / m
8 mm+4PVB+8 mm (88,4)
Glass height
600 mm
1000 mm
1200 mm
Handrail
No. of bases / m
L
-
4
265 mm
F85-200
4
265 mm
F85-201
4
265 mm
-
5
190 mm
F85-200
4
265 mm
F85-201
4
265 mm
-
5
190 mm
F85-200
5
190 mm
F85-201
5
190 mm
A20•line
Wedge on floor system
Installation step by step / Étapes d’ instalation
1
2
3
4
5
6
32
Technical
specifications
Specifications
techniques
A20•line
Pose sur dalle avec de profile de sol en une pièce
107,9
Glass supporting base / Base de support
65,9
Wedge Profile
Code
F85-460
Length
3m
Available in 3 meter pre-cut and pierced
Disponible en 3 metres percé
Accessories / Accessoires
33
Technical
specifications
50
109
108,5
Specifications
techniques
70,4
Pressure plate
Code
Package
25,6
Side cap
F85-455
20 pcs
Code
Base cover
F85-450
Package
20 pcs
Code
Drainage base profile
F85-1Κ50
Weight
572 gr/m
Length
6m
98
2000
Pressure plate restrainer
Code
Package
20
50
2000
PVC constrictor 1,5 mm
PVC constrictor 1,5 mm
F85-456
Code
F85-459
Code
F85-458
20 pcs
Color
Black
Color
Black
Length
2m
Length
2m
Code
Length
Package
F85-457
1m
10 pcs
A20u line
•
34
Info
In-floor Wedge system
Système engastré en
une pièce
S
U
ave time and money with this new system!
Floor profile supplied in precut and
drilled, at three meter length.
Specified glass is 88,4 and maximum height
at 1200 mm.
ne nouvelle conception de système
encastré.
Gagnez du temps, et d’ argent!
Profilé de sol, prêt à l’ emploi, verre
préconisé de 88,4, épaisseur de 17,52 mm.
Hauteur maximale de 1200 mm
Full transparency is now even more possible!
35
Info
A20u•line
In-floor Wedge system
Glass section A20u
16 mm
Min. 16,76 mm
Max. 17,52 mm
max. 17,52
15
115,4
8
1
9,6
108
F85-455
36
Technical
specifications
65,9
65,9
95,9
Specifications
techniques
F85-455
F85-951
US540-1PDM
F85-460
F85-1K51
F85-456
A20u•line
Système engastré en une pièce
Supporting base assembly / Installation
Standard supporting base type A20u assembly for glasses with a length of 1000 mm
1000
1000
mm
mm
m
m
m
50 m
L
50 m
L
5
0 mm
50 m
L
37
Technical
specifications
Specifications
techniques
Recommended number of bases / m
8 mm+4PVB+8 mm (88,4)
Glass height
Handrail
No. of bases / m
L
-
4
265 mm
600 mm
F85-200
4
265 mm
1000 mm
1200 mm
F85-201
4
265 mm
-
5
190 mm
F85-200
4
265 mm
F85-201
4
265 mm
-
5
190 mm
F85-200
5
190 mm
F85-201
5
190 mm
ATTENTION!
Pressure plate restrainer should be slided on floor
profile before final fixing.
ATTENTION!
Plaque de pression doit être monté anant la pose
finale.
A20u•line
In-floor Wedge system
Installation step by step / Étapes d’ instalation
1
2
3
4
38
Technical
specifications
Specifications
techniques
A20u•line
Système engastré en une pièce
50
50
9,
9
107,9
Supporting bases & accessories / Base de support & accessoires
37,2
65,9
Drainage base
Aluminium wedge
Code
F85-460
Length
3m
Code
Pressure plate restrainer
F85-455
Package
20 pcs
Code
Base cover
F85-456
Package
20 pcs
Available in three meter pre-cut and
pierced. Disponible en 3 metres percé
Code
F85-1Κ51
Weight
216 gr/m
Length
6m
Accessories & gaskets / Accessoires & joints
39
2000
Technical
specifications
109
98
Specifications
techniques
5,
3
20
2000
65,9
70,4
Side cap
Cover for in-floor guide
Code
F85-450
Package
20 pcs
9
5
Slug gasket
Code
Length
US540-1PD
200 m
PVC sheet 1,5 mm
PVC sheet 1,5 mm
Code
F85-951
Code
F85-459
Weight
235 gr/m
Color
Black
Length
6m
Length
2m
Code
F85-458
Color
Black
Length
2m
40
Info
C
C
ER
Y
B line
•
TIFIED B
ER
R
T I F I É PA
Adjustable system for
on-floor installation
Système réglable,
pose sur dalle
T
D
Advantages
Avantages
he additional use of a floor guide, on
which the supporting bases can be
quickly applied and perfectly aligned, makes
the concept of this system evolutionary.
Glass panels to be used are 88,4 and
thickness of 17,52 mm & 21,52 mm, the
maximum height is specified at maximum 1200
mm.
ƒƒ Unlimited view
ƒƒ Maximum security
ƒƒ Easy alignment
ƒƒ Additional floor guide
ƒƒ Additional pressure plates
ƒƒ Wide range of color choices (RAL, Sable,
metallic, anodized & wood finish)
ƒƒ Optional use of top handrail
es possibilités de réglage absolument
uniques rendent son montage encore
plus simple mais robuste en même temps. Les
bases de support se glissent sur le guide, ils s’
y fixent, et les vitres sont montés et sériés.
Dimensions de vitre préconisé à 88,4, à
17,52 mm & 21,52 mm d’ épaisseur.
ƒƒ Transparence illimitée
ƒƒ Sécurité maximal
ƒƒ Montage et alignement rapide et soigneux
ƒƒ Guidage de sol
ƒƒ Calles de pression
ƒƒ Choix de coloris (RAL, Sable, anodize & teint
de bois)
ƒƒ Option de main courante
Ultimate alignment has never been easier!
41
Info
B•line
42
B•line
43
B•line
B•line
Adjustable system for on-floor installation
max. 21,52
Glass section B
DIN 934 Μ8
(Included in the supporting base)
16 mm
20 mm
Min. 16,76 mm
Min. 20,76 mm
Max. 17,52 mm
Max. 21,52 mm
DIN 916 Μ8x20
(Included in the supporting base)
Tightening torque 5 Nm
Allen No.6
Fixing point
Detail de fixation
107
F85-150B/16
F85-150B/20
DIN 912 Μ10x70
Tightening torque 40 Nm
Allen No.8
30
28
ΕΒ912-1070
Ø17
Ø12
44
150
Μ10x40
Drill 16 mm
90
ΕΒ01Μ-1040
91,8
30
Technical
specifications
Specifications
techniques
87.9
EBM-75112G
TORX 7,5x112
F85-150Β
F85-430
EB7982-4219I
DIN 7982 4,2x19
Cross bit ΡΗ2
F85-1K30
F85-930
Balustrade Type
Tempered Glass Panel
Height of Balustrade
Static Loading Category
(Horizontal Loads)
Dynamic Loading Category
(Impact Test)
Crystalline-B
8.8.4 mm
1000 mm
Residential and Office
buildings, without wind load
Residential
and Office buildings
Crystalline-B
8.8.4 mm
1200 mm
Residential function,
without wind load
Residential function
Crystalline-B
8+2DG41+8 mm
1200 mm
Residential function,
with wind load up to 700Pa
Residential function
Crystalline-B
10.10.4mm
1200 mm
Residential and Office
buildings, without wind load
Residential function
Crystalline-B
10.10.4mm
mixed float laminate
1200 mm
Residential and Office
buildings, without wind load
Residential function
B•line
Système réglable, pose sur dalle
Supporting base assembly / Installation
Standard supporting base type B assembly for glasses with a length of 1000 mm
1000
1000
mm
mm
L
L
L
L
m
150 m
m
150 m
0 mm
m 15
150 m
m
150 m
m
150 m
45
Technical
specifications
Specifications
techniques
8 mm+4PVB+8 mm (88,4)
Recommended number of bases / m
Height
of glass
600 mm
1000 mm
1100 mm
1200 mm
10mm+4PVB+10mm (1010,4)
Handrail
No.
of bases / m
L
-
3
275 mm
F85-200
2
700 mm
F85-201
2
700 mm
-
3
275 mm
F85-200
3
275 mm
F85-201
3
-
4
F85-200
3
275 mm
F85-201
3
275 mm
-
5
62,5 mm
F85-200
4
133 mm
F85-201
4
133 mm
Glass
Height
600 mm
Handrail
No.
of bases / m
L
-
3
275 mm
F85-200
2
700 mm
F85-201
2
700 mm
-
3
275 mm
F85-200
3
275 mm
275 mm
F85-201
3
275 mm
133 mm
-
4
133 mm
F85-200
3
275 mm
F85-201
3
275 mm
-
5
62,5 mm
F85-200
4
133 mm
F85-201
4
133 mm
1000 mm
1100 mm
1200 mm
B•line
Adjustable system for on-floor installation
Installation step by step / Étapes d’ instalation
1
2
3
4
5
6
46
Technical
specifications
Specifications
techniques
B•line
Système réglable, pose sur dalle
Glass supporting bases / Base de support
The supporting bases include tightening screws, chock gaskets, gaskets and pressure plates
Glass base
F85-150B/01/16
(for glass 16 mm)
F85-150B/03/16
(8.8.4)
12 pcs
Code
Package
Glass base
F85-150B/02/20
(for glass 20 mm)
F85-150B/04/20
(10.10.4)
12 pcs
Code
Package
Profiles & accessories / Profiles & Accessoires
47
16,3
88,1
35,5
Base cover
Code
91,8
Base guide
F85-1K30
Code
107
107
100,3
Technical
specifications
91,8
Side end cap
F85-930
Weight
559 gr/m
Weight
1565 gr/m
Length
6m
Length
6m
Code
Side end cap (Optional)
F85-430
Package
20 pcs
Package
Available in Ral 9006
Disponible en Ral 2006
Gaskets / Joints
2
9,4
8,3
5,4
29
(PVC)
for Press
Plate
Slug gasket
Code
Length
Rubber gasket for base cover (PVC)
F85-421 (F85-431)
150 m
Code
F85-427
(8.8.4)
F85-432
(for glass 16 mm)
F85-433
(for glass 20 mm)
F85-420
(10.10.4)
Code
Slug gasket*
Code
Length
F85-434
250 m
* The use of a special slug gasket is
necessary only when installing a
8 mm+4PVB+8 mm glass and 16 mm
glass.
F85-430L
(8.8.4)
F85-430M
(10.10.4)
20 pcs
Specifications
techniques
Info
C
C
ER
R
T I F I É PA
C
TIFIED B
ER
ER
Y
48
C
Y
C2 line
•
TIFIED B
ER
R
T I F I É PA
On-Floor System
F
rame-less glass offers a seamless and
stylish appearance which is unmatched by
any other product.
For a sleek and unobtrusive look, Type C2
is the indisputable solution. The square line
supporting bases are fixed on the ground
profile and coved by fascia profiles, easy to
remove in case of glass replacement.
Glass panels specified for this system are:
88,4, 1010,4, thickness of 17,52 mm & 21,52
mm. Maximum height at 1200 mm.
Advantages
ƒƒ Seamless and stylish appearance
ƒƒ Complies to the strictest safety measures
(test results available)
ƒƒ Practical alignment from internal side of
balcony
ƒƒ Quick installation with a floor guide
ƒƒ Possibility of embedding the system
ƒƒ Optional use of handrail.
Top in transparency.
Maximum of light
and space!
49
Pose sur dalle
C
onçue pour répondre aux critères de
sécurités les plus strictes, en usage
résidentiel ou commercial tel que halles, salles
de loisir et centre commerciaux.
Les verres sont d’ une épaisseur déterminé
selon l’ emploi, allant de 88,4 à 1010,4,
épaisseur du 17,52 mm & 21,52 mm et
hauteur 1200 mm.
Info
Avantages
ƒƒ Transparent
ƒƒ Certifie par IFT Rosenheim
ƒƒ Alignement aisé
ƒƒ Option d’ encastrement
ƒƒ Option de main courante
C2•line
50
C2•line
51
C2•line
C2•line
On-Floor System
max. 21,52
Glass section C2
DIN 934 Μ8
(Included in the supporting base)
16 mm
20 mm
Min. 16,76 mm
Min. 20,76 mm
Max. 17,52 mm
Max. 21,52 mm
Fixing point
Detail de fixation
30
22
DIN 912 Μ10x70
Tightening torque 40 Nm
Allen No.8
ΕΒ01Μ-1040
Μ10x40
Drill 16 mm
Ø12
90
Ø12
150
52
F85-300C2/16
F85-300C2/20
30
F85-150C2/16
F85-150C2/20
ΕΒ912-1070
120
122,8
DIN 916 Μ8x25
(Included in the supporting base)
Tightening torque 5 Nm
Allen No.6
89
Specifications
techniques
300
30
Technical
specifications
F85-415/C2
F85-150/C2
120
PAT39-120
30
F85-426
F85-1K15
EB7982-4219I
DIN 7982 4,2x19
Cross bit ΡΗ2
Balustrade Type
Tempered Glass Panel
Height of Balustrade
Static Loading Category
(Horizontal Loads)
Dynamic Loading Category
(Impact Test)
Crystalline-C2
8.8.4 mm
1000 mm
Residential and Office buildings,
without wind load
Residential and Office buildings
Crystalline-C2
10.10.4 mm
1100 mm
Crystalline-C2
8.8.4 mm
1100 mm
Residential function
Residential and Office buildings,
without wind load
Residential and Office buildings,
and Dynamic Missile Impact
Test weight 4,5 kg
C2•line
Pose sur dalle
Supporting base assembly / Installation
Standard supporting base type C assembly for glasses with a length of 1000 mm
1000
1000
mm
mm
L
L
L
L
m
150 m
m
150 m
m
300 m
m
150 m
m
150 m
53
Technical
specifications
Specifications
techniques
8 mm+4PVB+8 mm (88,4)
Recommended number of bases / m
Glass
height
600 mm
1000 mm
1100 mm
1200 mm
10mm+4PVB+10mm (1010,4)
Handrail
No.
of bases / m
L
-
3
275 mm
F85-200
2
700 mm
F85-201
2
700 mm
-
3
275 mm
F85-200
3
275 mm
F85-201
3
-
4
F85-200
3
275 mm
F85-201
3
-
5
F85-200
4
133 mm
F85-201
4
133 mm
Glass
height
600 mm
Handrail
No.
of bases / m
L
-
3
275 mm
F85-200
2
700 mm
F85-201
2
700 mm
-
3
275 mm
F85-200
3
275 mm
275 mm
F85-201
3
275 mm
133 mm
-
4
133 mm
F85-200
3
275 mm
275 mm
F85-201
3
275 mm
62,5 mm
-
5
62,5 mm
F85-200
4
133 mm
F85-201
4
133 mm
1000 mm
1100 mm
1200 mm
C2•line
On-Floor System
Installation step by step / Étapes d’ instalation
1
2
3
4
5
6
54
Technical
specifications
Specifications
techniques
C2•line
Pose sur dalle
Supporting bases / Base de support
30
30
0
0m
m
m
m
The support bases include tightening screws and gaskets. Type C bases are used in the in-floor and on-floor glass support system.
Glass base
Glass base
F85-150C2/16
(8.8.4)
F85-150C2/20
(10.10.4)
12 pcs
Code
Package
F85-300C2/16
(8.8.4)
F85-300C2/20
(10.10.4)
6 pcs
Code
Package
Accessories & gaskets / Accessoires & joints
55
Technical
specifications
122,5
122,5
122,5
Specifications
techniques
32,7
88,8
88,8
Base cover
Code
Side cap
F85-1K15
Weight
705 gr/m
Length
6m
Code
Side cap (Optional)
F85-415/C2 L
(8.8.4)
F85-415/C2 M
(10.10.4)
20 pcs
F85-415/C2
Package
20 pcs
Code
Package
9,5
4,1
4,4
8,3
10,3
9,5
4,1
13,8
2,9
2,9
F85-422
Code
25,4
F85-426
Rubber gasket for base cover
F85-422
(8.8.4)
F85-426
(10.10.4)
16,6
Rubber gasket for base cover (PVC)
Code
F85-436
Alignment profile
Code
PAT39-120
Weight
121 gr/m
Length
6m
C2u line
•
56
Info
In-floor support system
Système Encastré
G
L
lass balustrades are unmatched for their
ability to bring safety, visual appeal and
practicality to any internal or external space.
Type C2U offers all of these qualities and
even more, in its “hidden“ in-floor assembly.
Suitable for swimming pools or any terrace
where no barriers to the feeling of freedom are
welcomed.
Glass panels to be used are 88,4 or 1010,4,
in thickness of 17,52 mm & 21,52 mm
maximum height of 1200 mm.
a vie en Verre! Le profile de sol et les
bases de support sont totalement
encastres dans le béton.
L’ ensemble est bien protégé par un
capuchon en profile et joints PVC.
La vitre préconisé est 88,4 ou 1010,4,
épaisseur a 17,52 mm & 21,52 mm et hauteur
maximale a 1200 mm.
Amazing look without any
interruptions, suitable for
both indoor and outdoor use!
57
Info
C2u•line
58
C2u•line
59
C2u•line
C2u•line
In-floor support system
Glass section C2u
max. 21,52
20 mm
Min. 20,76 mm
Max. 17,52 mm
Max. 21,52 mm
1,3
DIN 934 Μ8
(Included in the
supporting base)
14
16 mm
Min. 16,76 mm
20
20
123
DIN 916 Μ8x25
(Included in the
supporting base)
Tightening torque
5 Nm
Allen No.6
22
DIN 912 Μ10x70
Tightening torque
40 Nm
Allen No.8
123
ΕΒ912-1070
ΕΒ01Μ-1040
Μ10x40
Drill 16 mm
60
85
Technical
specifications
115
87
115
38,7
Specifications
techniques
F85-1M25
F85-1M5
F85-150C
F85-1K5
F85-425
EB7982-4219I
F85-1M15
DIN 7982 4,2x19
Cross bit ΡΗ2
Balustrade Type
Tempered Glass Panel
Height of Balustrade
Static Loading Category
(Horizontal Loads)
Dynamic Loading Category
(Impact Test)
Crystalline-C2
8.8.4 mm
1000 mm
Residential and Office buildings,
without wind load
Residential and Office buildings
Crystalline-C2
10.10.4 mm
1100 mm
Crystalline-C2
8.8.4 mm
1100 mm
Residential function
Residential and Office buildings,
without wind load
Residential and Office buildings,
and Dynamic Missile Impact Test
weight 4,5 kg
C2u•line
Système Encastré
Supporting base assembly / Installation
Standard supporting base type Cu assembly for glasses with a length of 1000 mm
1000
1000
mm
mm
L
L
L
L
m
150 m
m
150 m
m
300 m
m
150 m
m
150 m
61
Technical
specifications
Specifications
techniques
Recommended number of bases / m
8 mm+4PVB+8 mm (88,4)
10mm+4PVB+10mm (1010,4)
Height
height
Handrail
No.
of bases / m
L
-
3
275 mm
600 mm
F85-200
2
700 mm
F85-201
2
-
3
F85-200
3
275 mm
F85-201
3
275 mm
1000 mm
1100 mm
1200 mm
Height
height
Handrail
No.
of bases / m
L
-
3
275 mm
600 mm
F85-200
2
700 mm
700 mm
F85-201
2
700 mm
275 mm
-
3
275 mm
F85-200
3
275 mm
F85-201
3
275 mm
-
4
133 mm
F85-200
3
275 mm
F85-201
3
275 mm
-
5
62,5 mm
F85-200
4
133 mm
F85-201
4
133 mm
1000 mm
1100 mm
1200 mm
-
4
133 mm
F85-200
3
275 mm
F85-201
3
275 mm
-
5
62,5 mm
F85-200
4
133 mm
F85-201
4
133 mm
C2u•line
In-floor support system
Installation step by step / Étapes d’ instalation
1
62
Technical
specifications
Specifications
techniques
3
2
C2u•line
Système Encastré
Supporting bases / Base de support
123,1
Supporting bases are supplied with screws and gaskets. Bases compatible with C2u
100
,2
Glass base
Code
In-floor base guide
Glass base
Code
F85-1M5
F85-150C2/16
F85-300C2/16*
(8.8.4)
(8.8.4)
Weight
1976 gr/m
F85-300C2/20
Length
6m
F85-150C2/20
Code
(10.10.4)
Package
12 pcs
(10.10.4)
Package
6 pcs
63
Accessories & gaskets / Accessoires & joints
Technical
specifications
23,4
1,3
6,3
Specifications
techniques
43,6
44,8
Base cover
In-floor base guide cover
Additional profile for in-floor guide
F85-1K5
Code
F85-1M25
Weight
295 gr/m
Weight
360 gr/m
Length
6m
Length
6m
124,3
Code
Code
281 gr/m
Length
6m
4,4
13,8
100
16,6
25,4
In-floor base guide cap
Code
Package
F85-425
20 pcs
Rubber gasket for base cover (PVC)
Code
F85-1M15
Weight
F85-436
64
Info
C
C
ER
Y
D line
•
TIFIED B
ER
R
T I F I É PA
Fascia mount system
Pose sur nez de dalle
G
P
Advantages
Avantages
lass panels mounted on aluminium fascia
supporting channel, suitable for balconies,
terraces and staircases.
Extremely elegant and unobtrusive due
to the covering profiles and rosettes which
support the whole structure
Specified glass to be used is 88,4 & 1010,4,
in thickness of 17,52 mm & 21,52 mm
respectively. Maximum height at 1200 mm.
ƒƒ Total frame-less effect
ƒƒ Suitable for internally or externally
ƒƒ Mounted on external side of wall
ƒƒ Optional use of handrail
ƒƒ No drilling or damage of insulation
lus facile que jamais, avec ce système
de pose en appliqué (nez de dalle). Le
profile structuraux se fixe sur le mur et le verre
est monte avec des adaptateurs de verre. L’
habillage de l’ ensemble donne ce garde corps
son élégance et.
ƒƒ Effet tout verre
ƒƒ Utilisable a l’ intérieur et extérieur
ƒƒ Ergonomie d’ espace
ƒƒ Option de main courant
ƒƒ Protection d’ isolation thermique
Total frameless
effect down to the
last detail!
65
Info
D•line
66
D•line
67
D•line
D•line
Fascia mount system
max. 21,52
Glass section D
16 mm
58,2
F85-D016/20
DIN 7991 Μ12x45/50
Tightening torque 15 Nm
Allen No.8
20 mm
Min. 16,76 mm
Min. 20,76 mm
Max. 17,52 mm
Max. 21,52 mm
102
ΕΒ912-1070
DIN 912 Μ10x70
Tightening torque 40 Nm
Allen No.8
ΕΒ01Μ-1040
Μ10x40
Drill 16 mm
36,4
18
68
45
Technical
specifications
Specifications
techniques
500
50
F85-1K10
F85-D016/20
F85-1B10
DIN 7991 Μ12x45/50
Tightening torque 15
Nm
Allen No.8
F85-410
F85-1K20
500
90
Balustrade Type
Tempered Glass Panel
Height of Balustrade
Static Loading Category
(Horizontal Loads)
Dynamic Loading Category
(Impact Test)
Crystalline-D
8.8.4 mm
1100 mm Glass
Residential and Office buildings,
without wind load
Residential and Office buildings
D•line
Pose sur nez de dalle
Supporting base assembly / Installation
The support bases include tightening screws and gaskets. Type D bases are used in the in-floor and on-floor glass support system.
1000
mm
0 mm
10~2
1000
mm
L
m
200 m
L
L
m 200
200 m
L
mm
m
200 m
69
Ø18
Technical
specifications
Specifications
techniques
m
102 m
Recommended number of bases / m
36,4
mm
8mm+4PVB+8mm (88,4)
Height
600 mm
1000 mm
1200 mm
10mm+4PVB+10mm (1010,4)
Handrail
No.
of bases / m
L
-
2
600 mm
F50-200
2
600 mm
-
3
300 mm
F50-200
2
600 mm
-
4
200 mm
F50-200
3
300 mm
Height
600 mm
1000 mm
1100 mm
Handrail
No.
of bases / m
L
-
2
600 mm
F50-200
2
600 mm
-
3
300 mm
F50-200
2
600 mm
-
4
200 mm
F50-200
3
300 mm
D•line
Fascia mount system
Installation step by step / Étapes d’ instalation
1
70
Technical
specifications
Specifications
techniques
3
2
D•line
Pose sur nez de dalle
Supporting bases / Base de support
Wall base
Code
F85-1B10
Weight
4740 gr/m
Length
6m
Profiles & accessories / Profiles & accessoires
71
Technical
specifications
Specifications
techniques
58,2
Top Cover
Code
Bottom Cover
F85-1K10
Code
Glass Support Knurl (Inox304)
F85-D016
Code
F85-410
(8.8.4)
Color
White/Black
Weight
366 gr/m
Weight
220 gr/m
Length
6m
Length
6m
Code
F85-D020
(10.10.4)
Package
Gaskets / Joints
2.6
20
Base gasket
Code
Length
F85-437
200 m
PVC sheet 1 mm
F85-1K20
20 pcs
Length
2m
Ds line
•
72
Info
External support with glass Pose sur nez de dalle avec
brackets
des adaptateurs a verre
I
P
Advantages
Avantages
nstalling this system on your staircase or
balcony, a floating and totally frame-less
effect is gained.
The glass brackets in stainless steel of 40
and 50 diameter, are fixed directly on the
external wall. Additional brackets available for
use of handrail.
ƒƒ Perfect solution for staircases
ƒƒ Stunning look
ƒƒ Easy installation with 88,4 or 1010,4 securit
glass
our avoir de transparence sans limites!
Ce garde corps tout verre, sans structure
porteuse, s’ inscrive dans une tendance
architecturale forte. Les adaptateurs a verre
rond a 40 & 50 en inox brosse, offrent la
structure la robustesse et la beauté a la fois.
ƒƒ Effet tout verre
ƒƒ Esthétique luxueuse
ƒƒ Facile à monter de verre à 88,4 ou 1010,4
securit
Meet your
aesthetic
needs by
creating
a floating
and totally
frameless
effect!
73
Info
Ds•line
External support with glass brackets
Supporting base assembly / Installation
max. 21,52
Glass section Ds
41
150 min.
90 min.
16 mm
20 mm
Min. 16,76 mm
Min. 20,76 mm
Max. 17,52 mm
Max. 21,52 mm
ΕΒ912-1070
40
DIN 912 Μ10x70
Tightening torque 40 Nm
Allen No.8
74
ΕΒ01Μ-1040
Technical
specifications
Μ10x40
Drill 16 mm
Specifications
techniques
4149
100-300 max
150 min.
DIN 7991 Μ12x50
Tightening torque 15 Nm
Allen No.8
-300
100
max
Balustrade Type
Tempered Glass Panel
Height of Balustrade
Static Loading Category
(Horizontal Loads)
Dynamic Loading Category
(Impact Test)
Crystalline-Ds
8.8.4 mm
1200 mm Glass
Residential and Office buildings,
without wind load
Residential and Office buildings
ATTENTION :
Interconnection of glasses using a handrail (with a 4148
or F85-451 support) improves the static performance
ATTENTION :
L’ utilisation se main courante offre de meilleure
performance static
Ds•line
Pose sur nez de dalle avec des adaptateurs a verre
Supporting base assembly / Installation
max. 21,52
Glass section Ds
40
150 min.
90 min.
16 mm
20 mm
Min. 16,76 mm
Min. 20,76 mm
Max. 17,52 mm
Max. 21,52 mm
ΕΒ912-1070
55
DIN 912 Μ10x70
Tightening torque 40 Nm
Allen No.8
75
ΕΒ01Μ-1040
Technical
specifications
Μ10x40
Specifications
techniques
100-300 max
150 min.
4136
DIN 7991 Μ12x50
Tightening torque 15 Nm
Allen No.8
ATTENTION :
Interconnection of glasses using a handrail
(with a 4148 or F85-451 support) improves the static
performance
-300
100
max
ATTENTION :
L’ utilisation se main courante offre de meilleure
performance static
Ds•line
External support with glass brackets
Supporting base assembly / Installation
1000
1000
mm
mm
L
L
L
m
0m
m 15
150 m
L
Ø18
m
150 m
76
Technical
specifications
Recommended number of bases / m
100 mm 150 mm 90 mm
Specifications
techniques
8mm+4PVB+8mm (88,4)
Height
600 mm
1000 mm
1200 mm
10mm+4PVB+10mm (1010,4)
Handrail
No.
of bases / m
L
-
3
350 mm
F50-200
2
700 mm
-
3
350 mm
F50-200
3
350 mm
-
4
233 mm
F50-200
3
350 mm
Height
600 mm
1000 mm
1100 mm
Handrail
No.
of bases / m
L
-
3
350 mm
F50-200
2
700 mm
-
3
350 mm
F50-200
3
350 mm
-
4
233 mm
F50-200
3
350 mm
The stated results are only indicative and do not guarantee the system’s durability since they are not a result of a structural study
m
150 m
Ds•line
Pose sur nez de dalle avec des adaptateurs a verre
Accessories / Accessoires
75
Ø18*
Ø18*
40
40
Ø50
41
*glass hole
*glass hole
INOX glass support
Handrail support F50-200
4149-200*(Inox304)
Code
Package
Code
4148-200 (Inox304)
(8.8.4)
(8.8.4)
4149-201*(Inox316)
4148-201 (Inox316)
(10.10.4)
12 pcs (box)
4 pcs (blister)
(10.10.4)
12 pcs (box)
4 pcs (blister)
Package
77
Technical
specifications
Ø18*
55
40
*glass hole
INOX glass support
Code
Package
4136-200* (Inox316)
(8.8.4) (10.10.4)
12 pcs (box)
4 pcs (blister)
Specifications
techniques
Dc line
External support with
fascia aluminium profile
Système en applique
I
C
Advantages
Avantages
•
78
Info
n this version the supporting profiles are
totally covered by aluminium profiles, giving a
unique and seamless look.
Can be mounted with 88,4 and 1010,4
glass in thickness of 17,52 mm & 21,52 mm
respectively. Maximum height specified at
1200 mm.
ƒƒ Floating effect
ƒƒ Possibility of mounting the glass without any
drilling
ƒƒ External fascia mounting
ƒƒ No damage to installation
e type de Crystalline offre une solution
pratique et esthétique grâce a la pose sur
nez de dalle et son habillage avec les profiles
en aluminium.
Le verre spécifie est de 88,4 & 1010,4
et épaisseur de 17,52 mm & 21,52 mm
respectivement. Hauteur maximale a 1200
mm.
ƒƒ Effet tout verre
ƒƒ Pas de perçage
ƒƒ Habillage par aise
An even more transparent look
lets you utilize more space!
79
Info
Dc•line
External support with fascia aluminium profile
Supporting base assembly / Installation
max. 25,52
Glass section Dc
58,2
F85-D216/22/24
DIN 7991 Μ12x45/50/55
Tightening torque 18 Nm
Allen No.8
16 mm
20 mm
24 mm
Min. 16,76 mm
Min. 20,76 mm
Min. 24,76 mm
Max. 17,52 mm
Max. 21,52 mm
Max. 25,52 mm
ΕΒ912-1070
102
DIN 912 Μ10x70
Tightening torque 40 Nm
Allen No.8
ΕΒ01Μ-1040
Μ10x40
18
36,4
Drill 16 mm
80
Technical
specifications
45
Specifications
techniques
F85-D216/22/24
DIN 7991 Μ12x45/50/55
Tightening torque 18 Nm
Allen No.8
500
50
F85-1Κ10
F85-441
F85-1B10
F85-410
F85-446
500
90
EB7982-4219I
DIN 7982 4,2x19
Cross bit ΡΗ2
F85-1Κ20
F85-1Κ11
Balustrade Type
Tempered Glass Panel
Height of Balustrade
Static Loading Category
(Horizontal Loads)
Crystalline-Dc
8+2DG41+8 mm
float laminate
1360 mm Glass
Residential function, without wind load
Crystalline-Dc
10+2DG41+10 mm
float laminate
1360 mm Glass
Residential function, without wind load
Dynamic Loading Category
(Impact Test)
Dc•line
Système en applique
Supporting base assembly / Installation
Standard supporting base type Ds Drill assembly for glasses with a length of 1000 mm
1000
mm
90 mm
1000
mm
L
L
90 mm
90 mm
L
90 mm
L
Ø18
81
102 mm
Technical
specifications
Specifications
techniques
m
36 m
Recommended number of accessories / m
8mm+4PVB+8mm (88,4)
Glass
height
600 mm
1000 mm
1200 mm
10mm+4PVB+10mm (1010,4)
Handrail
No.
Access. / m
L
-
2
820 mm
F50-200
2
820 mm
-
3
410 mm
F50-200
2
820 mm
-
4
273 mm
F50-200
3
410 mm
Glass
height
600 mm
1000 mm
1100 mm
12mm+4PVB+12mm (1212,4)
Handrail
No.
Access. / m
L
-
2
820 mm
F50-200
2
820 mm
-
3
410 mm
F50-200
2
820 mm
-
4
273 mm
F50-200
3
410 mm
Glass
height
600 mm
1000 mm
1100 mm
Handrail
No.
Access. / m
L
-
2
820 mm
F50-200
2
820 mm
-
3
410 mm
F50-200
2
820 mm
-
4
273 mm
F50-200
3
410 mm
Dc•line
External support with fascia aluminium profile
Installation step by step / Étapes d’ instalation
1
82
Technical
specifications
Specifications
techniques
3
2
Dc•line
Système en applique
Supporting bases / Base de support
The glass support system type Dc uses type D profiles and accessories in combination with the following accessories
100
143,3
143,3
140
50
50
Glass Supporting Accessory
Code
Glass Supporting Accessory (end)
F85-440
Package
10 pcs
Code
F85-441
Package
10 pcs
83
Technical
specifications
Profiles & accessories / Profiles & accessoires
174,2
174,5
Specifications
techniques
28,6
Support Accessories
Fixing Screws (Inox304)
Side cap
Aluminium facing
Code
F85-1K11
Weight
1026 gr/m
Length
6m
F85-446/16
F85-D216
(8.8.4)
Code
(8.8.4)
F85-446/20
(10.10.4)
F85-446/24
Code
1 pair
(10.10.4)
F85-D224
(12.12.4)
Package
F85-D220
(12.12.4)
Package
20 pcs
C
ER
Y
C
TIFIED B
ER
T I F I É PA
R
Dc line
•
84
Info
NO DRILL
Evolutionary concept of external
fascia mounting, without any drilling
on the glass panels
Conseption revolutionaire
sans percer le verre!
T
C
Advantages
Avantages
he newest entry in the frame-less glass
systems, allowing the mounting of the
glass on aluminium profile guide and brackets.
Maximum height of glass must not exceed 100
cm.
ƒƒ Minimal and seamless design
ƒƒ Limitless view
ƒƒ Easy installation
ƒƒ No drilling required
e type de garde corps extérieur très
design, se caractérise par le verre
transparent, épais, maintenue par de fixations
en aluminium profile.
La main courante en aluminium anodise
brosse, ici optionnelle vient couronne l’
ensemble de cette réalisation.
ƒƒ Pas de perçage
ƒƒ Vision totale
ƒƒ Compatible avec Dc
ƒƒ Pas de perçage
Completely unique
for complex situations!
85
Info
Dc•line
Conseption revolutionaire sans percer le verre!
Supporting base assembly / Installation
max. 21,52
58,2
F85-D216/22
DIN 7991 Μ12x45/50
Tightening torque 22 Nm
Allen No.8
102
ΕΒ912-1070
86
DIN 912 Μ10x70
Tightening torque 40 Nm
Allen No.8
ΕΒ01Μ-1040
Technical
specifications
Μ10x40
Drill 16 mm
36,4
Specifications
techniques
45
Glass section Dc No Drill
16 mm
20 mm
Min. 16,76 mm
Min. 20,76 mm
Max. 17,52 mm
Max. 21,52 mm
Dc•line
Système en applique
Supporting base assembly / Installation
500
50
500
90
F85-204
(Required)
F85-906
F85-D216/22
DIN 7991 Μ12x45/50
Tightening torque 22 Nm
Allen No.8
F85-1Κ10
F85-442
F85-1B10
F85-410
F85-446
EB7982-4219I
DIN 7982 4,2x19
Cross bit ΡΗ2
F85-1Κ20
F85-1Κ11
87
Technical
specifications
Specifications
techniques
Dc•line
Conseption revolutionaire sans percer le verre!
Supporting base assembly / Installation
1000
min.
1000
mm
m
16 m
mm
Technical
specifications
Specifications
techniques
Max. 1000 mm
88
ATTENTION!
The specifications of this system are for:
a) maximum glass height of 1000 mm
b) use exclusively with a handrail.
ATTENTION!
Spécifications du système:
a) hauteur du verre maximale de 1000 mm
b) application de main courante obligatoire
Dc•line
Système en applique
Supporting base profiles / Profiles de base de support
The glass support system type Dc uses type D profiles and accessories in combination with the following accessories
100
50
22
Glass Supporting Accessory
Code
F85-440
Package
155
143,30
143,30
100
10 pcs
Glass Supporting Accessory (end)
Code
F85-442
Package
10 pcs
Wall base
Glass Spacer Profile
Code
F85-1B10
Code
Weight
4740 gr/m
Length
Length
6m
F85-906
1m
Accessories & gaskets / Accessoires & joints
89
Technical
specifications
174,20
174,50
Specifications
techniques
28,6
0
Cap Front:
Side cap
Code
Code
(8.8.4)
Weight
1026 gr/m
Weight
366 gr/m
Weight
220 gr/m
F85-446/20
Length
6m
Length
6m
Length
6m
F85-D216
(8.8.4)
F85-D220
(10.10.4)
Package
20 pcs
F85-1K10
2000
1 pair
Support Accessories
Fixing Screws (Inox304)
Code
Bottom Cover
F85-1K11
(10.10.4)
Package
Top Cover
Code
F85-446/16
Base gasket
PVC sheet 1 mm
Code
F85-410
Color
White/Black
Length
2m
Code
Length
F85-437
200 m
Code
F85-1K20
90
Info
C
C
ER
Y
E line
•
TIFIED B
ER
T I F I É PA
R
Heavy duty on floor system
G
lass balustrades are unmatched for their
ability to bring safety, visual appeal and
practicality to high traffic external spaces. The
excellent engineering design of this system
with the certified mechanical properties make it
a signature product.
Safety is no longer a question or concern,
for any type of construction even with the
strictest specifications.
Specified glass panels in 88,4, 1010,4 and
1212,4 with thickness of 17,52 mm, 21,52
mm and 25,52 mm, are to be used with this
system.
Advantages
ƒƒ Excellent mechanical properties
ƒƒ Certified with glass panels at 1200 mm
without handrail
ƒƒ Designed for heavy use
ƒƒ Wide range of glass thicknesses
ƒƒ Assembly and alignment from internal side of
balcony
ƒƒ Safety guarantied
ƒƒ Suitable for crowded public spaces such as
museums, hospitals, office buildings, sports
stadiums and shopping centers
A powerful
statement
and the
ultimate
answer for
maximum
strength and
safety!
91
Système de haute exigence
Q
uand la sécurité rencontre la
transparence, c’ est grâce au système
Type E qui les en offrent.
La combinaison de profiles de sol avec les
bases de support très robuste, et l’ usage
de vitre a 88,4, 1010,4, 1212,4 à l’ épaisseur
de 17,52 mm, 21,52 mm et 24,52 mm, les
demandes les plus exigeants sont satisfaits.
Le système Type E a fait l’ objet de tests
de résistance mécanique, garantie d’ une
utilisation sans risque dans les conditions les
plus sévères.
Le verre est fixé par serrage, aucune
perçage est requis. Le système peut être
utilisé dans des éspaces publiques et de grand
trafique: hôpitaux, centres commerciaux,
aéroports, salles de spéctacles et stade de
sports.
Info
Avantages
Système livré prêt à l’emploi.
ƒƒ Robustesse
ƒƒ Longévité
ƒƒ Certifie sans main courante.
ƒƒ Flexibilité à l’ adoption de verre
ƒƒ Choix de coloris: RAL, Sable, anodise
brosse
ƒƒ Sécurité maximale
E•line
92
E•line
93
E•line
E•line
Heavy duty on floor system
Supporting base assembly / Installation
Glass section E
max. 25,52
DIN 934 Μ8
(Included
in the supporting base)
16 mm
20 mm
24 mm
Min. 16,76 mm
Min. 20,76 mm
Min. 24,76 mm
Max. 17,52 mm
Max. 21,52 mm
Max. 25,52 mm
DIN 916 Μ8x25
169
(Included
in the supporting base)
Tightening torque 2 Nm
Allen No.6
Fixing point
Detail de fixation
F85-300E/16 F85-300E/20
F85-300E/24
(Included
in the supporting base)
Tightening torque 22 Nm
Allen No.6
44
DIN 934 Μ8
(Included
in the supporting base)
38,5
DIN 912 Μ8x70
Ø17
ΕΒ912-1070
DIN 912 Μ10x70
124,5
Tightening torque 40 Nm
Allen No.8
ΕΒ01Μ-1040
Μ10x40
94
Drill 16 mm
Technical
specifications
87,5
300
96,5
Specifications
techniques
98,5
F85-300E
EB7982-4219I
DIN 7982 4,2x19
38,5
Cross bit ΡΗ2
F85-445
F85-1K40
F85-940
Balustrade Type
Tempered Glass Panel
Height of Balustrade
Static Loading Category
(Horizontal Loads)
Crystalline-E
12.12.4 mm
1200 mm
Public Function / stadiums – 3KN
Crystalline-E
Crystalline-E
Crystalline-E
Crystalline-E
Crystalline-E
Crystalline-E
10.10.2mm
float laminate
10.10.4mm
float laminate
12.12.4mm mixed float
laminate
12+4DG41+12mm
float laminate
12+4DG41+12mm
float laminate
8.8.4mm
1200 mm
1200 mm
1200 mm
1200 mm
1200 mm
1100mm
Residential and Office buildings,
with wind load 540 Pa up to 800 Pa
Residential and Office buildings,
with wind load up to 1080 Pa
Residential and Office buildings,
with wind load 540 Pa up to 800 Pa
Residential and Office buildings,
with wind load up to 1080 Pa
Residential and Office buildings,
with wind load up to 1080 Pa
Residential and Office buildings,
without wind load
Ø12
Dynamic Loading Category
(Impact Test)
Residential and Office buildings
Public function
Residential and Office buildings
Residential and Office buildings,
and Public Function
Residential and Office buildings, and Public Function
Residential and Office buildings,
and Dynamic Missile Impact Test weight 4,5kg
E•line
Système de haute exigence
Supporting base assembly / Installation
Standard supporting base type E assembly for glasses with a length of 1000 mm.
1000
1000
mm
mm
L2
L2
L2
m
300 m
m
300 m
L1
m
300 m
L1
m
300 m
95
m
300 m
Technical
specifications
Specifications
techniques
Recommended number of bases / m
8mm+4PVB+8mm (88,4)
10mm+4PVB+10mm (1010,4)
Height
height
Handrail
L1
L2
-
125 mm
200 mm
600 mm
F85-200
550 mm
700 mm
F85-201
550 mm
-
125 mm
F85-200
125 mm
200 mm
F85-201
125 mm
200 mm
-
125 mm
200 mm
F85-200
125 mm
200 mm
F85-201
125 mm
200 mm
1000 mm
1200 mm
12mm+4PVB+12mm (1212,4)
Height
height
Handrail
L1
-
125 mm
200 mm
600 mm
F85-200
550 mm
700 mm
700 mm
F85-201
550 mm
700 mm
200 mm
-
125 mm
200 mm
F85-200
125 mm
200 mm
F85-201
125 mm
200 mm
-
125 mm
200 mm
F85-200
125 mm
200 mm
F85-201
125 mm
200 mm
1000 mm
1100 mm
L2
Height
height
600 mm
1000 mm
1200 mm
Handrail
L1
L2
-
125 mm
200 mm
F50-200
550 mm
700 mm
-
125 mm
200 mm
F50-200
125 mm
200 mm
-
125 mm
200 mm
F50-200
125 mm
200 mm
E•line
Heavy duty on floor system
Installation step by step / Étapes d’ instalation
1
2
3
4
5
6
96
Technical
specifications
Specifications
techniques
E•line
Système de haute exigence
Glass supporting bases & accessoires / Bases de support & accessoires
169
165,40
The supporting bases include tightening screws, chock gaskets, gaskets and pressure plates.
35,4
87,5
0
Glass base
Base cover
F85-300E/16
Code
7
0
Base guide
Side cap
Code
F85-1K40
Code
F85-940
(8.8.4)
Weight
1185 gr/m
Weight
373 gr/m
(8.8.4)
F85-300E/20
Length
6m
Length
6m
F85-445/20
(10.10.4)
Available in Ral 9006
Disponible en Ral 9006
F85-300E/24
F85-445/16
Code
(12.12.4)
Package
(10.10.4)
F85-445/24
(12.12.4)
6 pcs
Package
1 pair
97
Technical
specifications
Specifications
techniques
Gaskets / Joints
18,1 / 22,1 / 26,1
23,4
8.8
8
28,1 / 32,1 / 36,1
Glass Gasket
Code
Length
Rubber gasket for base cover (PVC)
EA410-409M
F85-427
200 m
(8.8.4)
Code
F85-428
(10.10.4)
F85-429
(12.12.4)
L line
•
98
Info
Heavy duty on floor system
T
op mount adjustable system (in terms
of alignment and differential ± 1 ° of
the glass) heavy duty aluminum profile
construction glass balustrade on finished floor.
The aluminium base at 3m without an
additional cap, internal sedans and compact
single gasket ensure flawless aesthetics,
excellent support and perfect alignment of the
system.
The system accepts glazing 88.4 and
1010.4 thicknesses: 17.52 and 21.52,
respectively, and up to 1200mm height. This
allows very wide range of applications with
special safety requirements.
Advantages
ƒƒ Excellent mechanical properties
ƒƒ Wide range of applications (side mount - top
mount)
ƒƒ Single base at 3 m without additional
external lid
ƒƒ Adjustable in terms of alignment and
deviation (±1°) of the glasses
ƒƒ Tempered glass of 88,4 and 1010,4
thicknesses up to 21,52 mm
ƒƒ Glass carriers and solid gasket provide
excellent glass support and ultimate glass
balance
ƒƒ Assembly and alignment of the rail system
from the inside of the balcony
ƒƒ Safety guarantied
ƒƒ Suitable for commercial or residential use
ƒƒ Indoor and outdoor
Enjoy the
harmony of
simplicity
and style!
99
Système de haute exigeance
Top montage système réglable (en termes
d'alignement et de différentiel ± 1 ° du
verre) robuste profilé en aluminium verre de
construction balustrade sur sol fini.
La base d'aluminium à 3m sans capot
supplémentaire, berlines internes et joint
unique compact assurer une esthétique
irréprochable, un excellent support et un
alignement parfait du système.
Le système accepte vitrage 88,4 et 1010.4
épaisseurs: 17,52 et 21,52, respectivement,
et jusqu'à 1200mm hauteur. Cela permet
très large gamme d'applications avec des
exigences, de sécurité particulières.
Info
Avantages
ƒƒ Excellentes propriétés mécaniques
ƒƒ Une large gamme d'applications (montage
côté - top monter)
ƒƒ base simple à 3 m sans couvercle externe
supplémentaire
ƒƒ Réglable en termes d'alignement et de
déviation (± 1 °) des verres
ƒƒ Le verre trempé de 88,4 et 1010,4
épaisseurs jusqu'à 21,52 mm
ƒƒ Supports de verre et solide joint offrent un
excellent support de verre et de l'équilibre
de verre ultime
ƒƒ L'assemblage et l'alignement du gardecorps à l'intérieur du balcon
ƒƒ Sécurité guarantied
ƒƒ Convient pour un usage commercial ou
résidentiel
ƒƒ Intérieur et extérieur
L•line
100
L•line
101
L•line
SIDE MOUNTING
L•line
Heavy duty on floor system
17.52
EOF85-0477
88-4PVB=17,52mm
(88-2PVB=16,76mm)
EOF85-0478
EPDM
EPDM
F85-1B61
77
EOF85-0482 (profile F85-971)
Side carriage
F85-1K62
EOF85-0473
(EOF85-0573)
EOF85-0483 (profile F85-971)
Middle carriage
ABS plastic
EOF85-0484 / Ø22POM-C
(EOF85-0485 / Ø25POM-C)
EOF85-0475
ABS plastic
130
26
28
21.52
DIN 7991-M12x100
68
102
EOF85-0471
(EOF85-0571)
Anchor M12
EB01M.1285G01
ABS plastic
Drill 18 mm
EOF85-0482 (profile F85-971)
Technical
specifications
EOF85-0477
Specifications
techniques
EOF85-0478
EPDM
DIN 933-M8x1,25x40
77
EPDM
F85-1B61
F85-1K61
77
1010-4PVB=21,52mm
(1010-2PVB=20,76mm)
EOF85-0474
(EOF85-0574)
ABS plastic
EOF85-0482 (profile F85-971)
Side carriage
EOF85-0486 / Ø18POM-C
(EOF85-0487 / Ø20POM-C)
EOF85-0475
ABS plastic
130
26
28
DIN 7991-M12x100
68
EOF85-0472
(EOF85-0572)
ABS plastic
Anchor M12
EB01M.1285G01
Drill 18 mm
EOF85-0482 (profile F85-971)
EOF85-0483 (profile F85-971)
Middle carriage
DIN 933-M8x1,25x40
77
Balustrade Type
Tempered Glass Panel
Height of Balustrade
Static Loading Category
(Horizontal Loads)
Dynamic Loading Category
(Impact Test)
Crystalline – L line
Side Mount
10+2DG41+10 mm float
laminate
1300 mm Glass
Residential and Office buildings,
with wind load up to 690 Pa
Residential and Office buildings
montage latéral
L•line
Système de haute exigeance
Fixing detail (Drilling scheme)
Standard side mounting type L assembly for glasses with a length of 3000 mm.
68
A
Ø13
130
68
Ø13
Ø25
Ø13
Ø25
Ø13
Ø25
Ø13
Ø25
Ø25
A
250
125
250
250
125
3000
Ø25
Ø25
Ø25
Ø25
Ø25
77
Ø13
Ø13
Ø13
Ø13
Ø13
103
Technical
specifications
Specifications
techniques
Orientation of wedges & poms for side mounting Type L
Standard side mounting type L assembly for glasses with a length of 1000 mm.
20°
20°
20°
20°
70
60
10
10
40
10
70
60
10
70
MIDDLE CARRIAGE
SIDE CARRIAGE
70
125
SIDE CARRIAGE
70
250
250
1000
70
250
125
SIDE MOUNTING
L•line
Heavy duty on floor system
Installation step by step / Étapes d’ instalation
250
250
250
255
250
250
255
140
125
1
2
220
220
104
Technical
specifications
Specifications
techniques
3
4
335
60
!
5
!
6
Adhensive tale Lohman DuploColl 373, thickness: 0,33 mm, width: 15 mm
montage latéral
L•line
Système de haute exigeance
Corner connection of side mounting Type L
300
100
Ø25
Ø25
Ø13
300
100
Ø25
Ø25
Ø13
105
Technical
specifications
Specifications
techniques
100
300
Ø13
Ø25
Ø25
300
Ø25
Ø25
Ø13
100
SIDE MOUNTING
L•line
Heavy duty on floor system
Horizontal alignment pin
Ø4
Ø4,50
Ø4,00
15
9
30
6
Ø4,5
ATTENTION!
For structures bigger than 3 m in
length, we have to use horizontal
alignment pin
CONNECTOR PIN
106
Technical
specifications
Specifications
techniques
Rain water drain material cut-off for base profile, in order to ease rain water off our structure
3000
50
10
16
10
16
10
5
Rainwater drain
Detail view
0
50,0
5,00
50
25
3000
Ø10
1500
3000
1500
10
5
montage latéral
L•line
Système de haute exigeance
Profiles & Accessories / Profiles & Accessoires
Outsice slot cap
Code
Base U-Profile
Weight
F85-1B61
(10.10.4)
(8.8.4)
7500 gr/m
Length
3m
Code
Mobile Trolley
Code
F85-482
Weight
117 gr/m
Length
70 mm
POM - Intermediate wedge
Code
(8.8.4)
(8.8.4)
F85-485 Ø25
F85-573
F85-474
(10.10.4)
(10.10.4)
F85-487 Ø20
F85-574
(10.10.2)
(10.10.2)
70 mm
Length
Code
EB01M.1285G01
97 gr/m
70 mm
Internal corner
Weight
F85-1K61
(10.10.4)
(10.10.2)
F85-1K62
(8.8.4)
(8.8.2)
178 gr/m
Length
3m
Code
(8.8.2)
F85-486 Ø18
Length
Length
F85-483
Base inside cover
F85-473
Code
Anchor M12
Stationary Trolley
Weight
Basic wedge (PVC)
F85-484 Ø22
(8.8.2m)
Code
F85-475
Code
F85-466
Length
30x30 cm
External corner
Code
F85-469
Length
30x30 cm
Side end cap
Gaskets / Joints
Length
Glass 88,4PVB/88,2PVB support
Code
Glass 1010,4PVB/1010,2PVB support
F85-472
Code
(8.8.4)
(10.10.4)
Length
F85-572
Hardness
F85-571
Code
(8.8.2)
Length
70 mm
(10.10.2)
Length
70 mm
F85-488
77x130 mm
Counter - Balance gasket
F85-471
F85-477
100 m
100 shore
Technical
specifications
Specifications
techniques
70 mm
Code
107
Main gasket
Code
Length
F85-478
100 m
TOP MOUNTING
L•line
Heavy duty on floor system
88-4PVB=17,52mm
(88-2PVB=16,76mm)
21.52
EOF85-0482 (profile F85-971)
Side carriage
EOF85-0477
EPDM
EOF85-0478
EPDM
F85-1B61
F85-1K62
77
EOF85-0483 (profile F85-971)
Middle carriage
EOF85-0473
(EOF85-0573)
17.52
ABS plastic
EOF85-0484 / Ø22POM-C
(EOF85-0485 / Ø25POM-C)
130
108
EOF85-0477
EPDM
Technical
specifications
EOF85-0471
(EOF85-0571)
Specifications
techniques
EOF85-0482 (profile F85-971)
EOF85-0478
EPDM
F85-1B61
ABS plastic
F85-1K61
77
DIN 933-M8x1,25x40
77
Ø14.5
FISCHER concrete screw FBS-S
EBM12.0100G01
1010-4PVB=21,52mm
(1010-2PVB=20,76mm)
EOF85-0474
(EOF85-0574)
Drill 12 mm
ABS plastic
EOF85-0486 / Ø18POM-C
(EOF85-0487 / Ø20POM-C)
130
EOF85-0472
(EOF85-0572)
EOF85-0482 (profile F85-971)
Side carriage
ABS plastic
EOF85-0482 (profile F85-971)
DIN 933-M8x1,25x40
EOF85-0483 (profile F85-971)
77
Middle carriage
Ø14.5
FISCHER concrete screw FBS-S
EBM12.0100G01
Drill 12 mm
Balustrade Type
Tempered Glass Panel
Height of Balustrade
Static Loading Category
(Horizontal Loads)
Dynamic Loading Category
(Impact Test)
Crystalline – L line
Top Mount
10+2DG41+10 mm
float laminate
1200 mm Glass
Residential and Office buildings,
with wind load up to 800 Pa
Residential and Office buildings and
gathering places up to regulation
Class C3 (uniform load 1,7 KN/m).
montage supérieur
L•line
Système de haute exigeance
Supporting base assembly / Installation
Ø15
Standard top mounting type L assembly for glasses with a length of 3000mm.
Ø12,5
A
130
A
250
125
250
250
125
3000
Ø15
77
Ø15
Ø15
Ø15
Ø15
38.5
109
Technical
specifications
Specifications
techniques
Orientation of wedges & poms for side mounting Type L
Standard top mounting type L assembly for glasses with a length of 1000mm.
20°
20°
10
10
60
5
TECAFORM AH- POM-C
70
70
40
70
70
250
250
1000
60
10
10
5
SIDE CARRIAGE
MIDDLE CARRIAGE
SIDE CARRIAGE
70
125
20°
20°
70
250
125
TOP MOUNTING
L•line
Heavy duty on floor system
Installation step by step / Étapes d’ instalation
255
255
140
250
250
250
250
125
1
2
220
220
110
Technical
specifications
Specifications
techniques
3
4
335
60
!
5
!
6
Adhensive tape Lohman DuploColl 373 - thickness 0,33 mm - width 15 mm
montage supérieur
L•line
Système de haute exigeance
Corner connection for top mounting Type L
Externall connector corner
Side mound F85-479
75
Ø15
200
125
125
200
Ø15
75
111
Technical
specifications
Specifications
techniques
Internal connector corner
Side mound F85-467
200
125
75
Ø15
125
45°
200
Ø15
75
TOP MOUNTING
L•line
Heavy duty on floor system
Supporting base assembly / Installation
Horizontal alignment pin
Ø4
Ø4,50
Ø4,00
15
9
30
6
ATTENTION
For structures bigger than
3 m in length, we have to
use horizontal alignment
pin
Ø4,5
112
CONNECTOR PIN
Technical
specifications
Specifications
techniques
Rain water drain material cutoff for base profile, in order to ease rain water off our structure
3000
50
10
16
10
16
10
5
0
50,0
Rainwater drain
Detail view
5,00
50
25
3000
Ø10
1500
3000
1500
10
5
montage supérieur
L•line
Système de haute exigeance
Profiles & Accessories / Profiles & Accessoires
Mobile Trolley
Base U-Profile
Weight
F85-1B61
(10.10.4)
(8.8.4)
7500 gr/m
Length
3m
Code
Code
F85-482
Weight
117 gr/m
Length
70 mm
POM - Intermediate wedge
Code
Length
F85-484 Ø22
(8.8.4)
F85-485 Ø25
(8.8.2)
F85-486 Ø18
(10.10.4)
F85-487 Ø20
(10.10.2)
70 mm
Basic wedge (PVC)
F85-473
(8.8.4)
F85-573
(8.8.2)
F85-474
(10.10.4)
F85-574
(10.10.2)
70 mm
Code
Length
Code
Side end cap
Stationary Trolley
Weight
Length
F85-483
97 gr/m
70 mm
Code
Length
Concrete Screw Ø12-110
Code
Internal corner
EBM12-110
Code
Length
Extermal corner
Code
Length
Glass 88,4PVB/88,2PVB support
Length
F85-471
(8.8.4)
F85-571
(8.8.2)
70 mm
Glass 1010,4PVB/1010,2PVB support
Length
Hardness
F85-477
100 m
100 shore
F85-472
(10.10.4)
F85-572
(10.10.2)
70 mm
Code
Length
Counter - Balance gasket
Code
F85-467
30x30 cm
Main gasket
Code
Length
F85-478
100 m
113
Technical
specifications
Specifications
techniques
Gaskets / Joints
Code
F85-488
77x130 mm
Base inside cover
Weight
F85-1K61
(10.10.4)
(10.10.2)
F85-1K62
(8.8.4)
(8.8.2)
178 gr/m
Length
3m
Code
F85-479
30x30 cm
114
Info
Top handrails
& brackets
A
ll Crystalline systems can be optionally
mounted with a top handrail.
Available in three different sizes and shapes,
two round one of 50 mm diameter and an oval
in 76 mm width. The handrails are designed to
be mounted and secured on the glass panel
using rubber gaskets.
In cases where the handrail is desired or
specified to be side mounted on the glass
panel, special brackets are applied on the
drilled glass panel.
Available in all RAL shades, wood imitation
and brushed anodized same as all Crystalline
profiles.
Main courantes
& fixations
T
oute la gamme de systèmes Crystalline
peut adapter des main courantes.
ALUMINCO propose trois types de main
courantes, deux en rond de diamètre 50 mm
et une ovale a 73 cm de largeur. Elles sont
monte a l’ aide de joints et fixe au dessous ou
bien sur verre avec des supports .
Disponibles en tout teint de RAL, sable et
anodise brosse, comme l’ ensemble de profiles
Crystalline.
115
Info
Top handrails & brackets
Installation step by step / Etapes d’ instalation
1
2
Round handrail
116
Profile
Technical
specifications
Rubber gasket
Specifications
techniques
Oval shaped handrail
F85-204
F85-406 (for glass 17,52)
F85-407 (for glass 21,52)
Profile
Rubber gasket
F85-406 (for glass 17,52)
EA 410-420M
F85-321 (21,52)
F85-407 (for glass 21,52)
6
Round handrail
F85-202
F85-317 (17,52)
Profile
5
Round handrail
Rubber gasket
Handrail 17,52 mm & 21,52 mm
F85-203
4
Profile
3
Profile
Part
Round handrail
F50-200
4148-200
Profile
F50-200
Part
F85-451
L•line
Système
haute exigeance
Maindecourantes
& fixations
Supporting base assembly / Installation
117
Technical
Technical
specifications
specifications
Specifications
Specifications
techniques
techniques
Glass
Glass detail / Detail du verre
Glass thickness (T)
118
Technical
specifications
Specifications
techniques
4 PVB
3 PVB
2 PVB
1 PVB
}
1,52 mm
Glass thickness (T)
Verre
1000
Height: 1000 mm
T: (8+1,52+8) 17,52 mm
Code
W
Weight Kgr
F85-GL16U10
600
24
F85-GL16U11
800
32
F85-GL16U07
900
36
F85-GL16U08
1000
40
F85-GL16U12
1100
44
F85-GL16U09
1200
48
F85-GL16U13
1300
Immediately available from stock!
52
Height: 1000 mm
W
T
Glass dimensions 1000 mm / Dimensions de verre 1000 mm
T: (5+0,76+5) 10,76 mm
Code
W
Weight Kgr
F85-GL10U03
500
12,5
F85-GL10U04
600
15
F85-GL10U05
800
20
F85-GL10U01
900
22,5
F85-GL10U02
1000
25
F85-GL10U06
1100
27,5
F85-GL10U07
1200
30
Immediately available from stock!
119
Technical
specifications
Specifications
techniques
1100
Height: 1100 mm
T: (8+1,52+8) 17,52 mm
Code
W
F85-GL16U14
600
26,4
F85-GL16U15
800
35,2
39,6
F85-GL16U16
900
F85-GL16U12
1000
44
F85-GL16U17
1100
48,4
F85-GL16U18
1200
52,8
Immediately available from stock!
W
T
Glass dimensions 1100 mm / Dimensions de verre 1100 mm
Dimensions may vary due to perimetric grinding.
Weight Kgr
Accessories
Glass supporting system
Handrail profiles / Main courrante profiles
Ø50
Ø50
Ø50
39
25
76
12
25
Oval shaped handrail
Code
Round handrail
Round handrail
F85-203
Round handrail
Code
F85-204
Code
F50-200
Code
F85-202
Weight
1096 gr/m
Weight
973 gr/m
Weight
814 gr/m
Weight
721 gr/m
Length
6m
Length
6m
Length
6m
Length
6m
120
Technical
specifications
Specifications
techniques
18,1
12
22,1
Handrail 17,52 mm
Code
F85-317
Weight
198 gr/m
Length
6m
12
Handrail 21,52 mm
Code
F85-321
Weight
219 gr/m
Length
6m
Handrail caps / Embouts
Handrail cap F85-203
Code
Package
F85-403
80 pcs. (box)
8 pcs. (blister)
Handrail cap F85-202/204
Code
Package
F85-404
80 pcs. (box)
8 pcs. (blister)
Handrail cap F50-200
Code
Package
4434
50 pcs. (box)
2 pcs. (blister)
Handrail cap F50-200 flat
Code
Package
4453
50 pcs.
Accessoires
et viserie
Handrail connection accessories, seam covers / Connecteurs angulairs
Code
Handrail connector
F85-202/204 Straight
Package
4251
40 pcs. (box)
8 pcs. (blister)
Code
Handrail connector
F85-202/204 Angled
Package
Handrail seam cover F85-203
4253
40 pcs.
Code
Package
F85-402
45 pcs. (box)
4 pcs. (blister)
Handrail seam cover Ø50 with cover
Code
Package
4509Ζ
20 pcs. (box)
4 pcs. (blister)
Handrail supports / Support de main courrante
121
Technical
specifications
Specifications
techniques
Wall support for handrail F85-202
Wall support for handrail F50-200
Wall support for handrail F50-200
Wall support for handrail F50-200
Code
Code
Code
Code
Package
F85-452
40 pcs.
Handrail support F50-200
Code
Package
F85-451
25 pcs. (box)
2 pcs. (blister)
Package
4165
40 pcs.
Handrail support F50-200
Code
Package
4148-200* (Inox304)
4148-201* (Inox316)
12 pcs. (box)
4 pcs. (blister)
Package
4140
20 pcs.
Package
4141
20 pcs.
Accessories
Glass supporting system
Handrail gaskets / Joints de main courrante
24,8
24,8
24,7
23,7
“U“ shaped gasket
“U“ shaped gasket
F85-406
Code
(8.8.4)
Package
50 m
Code
Slug gasket
F85-407
Code
(10.10.4)
Package
Package
ΕΑ410-420Μ
350 m
50 m
for glass / pour verre 8 mm+4PVB+ 8 mm
Miscellaneous / Divers
122
Technical
specifications
Specifications
techniques
Glass Alignment Knurl*
Code
Package
F85-D130
(8.8.4)
(10.10.4)
10 pcs.
Type Α cover extractor
Code
F85-E011
Package
1 pcs.
Fixing screw / Viserie
Inox allen screw Μ10x70
Code
Package
EB912-1070
50 pcs.
Expansion plug
Code
Package
Concrete Torx 7,5x112
EB01M-1040
50 pcs.
Code
Package
EBM-75112G
50 pcs.
Crystalline Promo display
123
Technical
specifications
Specifications
techniques
Sample Stand Chrystal-Line
Code
F85-401
124
Info
125
Info
320 11 Inofita Viotia, Greece
T. +30 22620 47000
F. +30 22620 47090
www.aluminco.com
info@aluminco.com
export@aluminco.com
Version June 2016
This catalogue supersedes all previous ones