Special profile steel joists - New Millennium Building Systems
Transcription
Special profile steel joists - New Millennium Building Systems
Special Profile Steel Joists • 40,000+ Engineered Design Specifications • Gable, Bowstring, Scissor, and Arch Joist Profiles • Nationwide Engineering and Manufacturing GABLE Introduction to Products and Services .............................. 2 Special Profile Joists ....................................................... 10 Availability Design Fire Ratings SP-Series Design ............................................................ 14 Horizontal Reactions Load Adjustment Factors Scissor Joist Design Example Bowstring Joist Design Example Special Profile Joists FLAT TOP GABLE Introduction Table of Contents Gable Joist (SPGB) Tables ............................................. 24 Bowstring Joist (SPBW) Tables ....................................... 40 SCISSOR Scissor Joist (SPSC) Tables ............................................. 56 SP-Series Standard Specification ................................... 88 COMPOUND SCISSOR SP-Series Design Arch Joist (SPAC) Tables ................................................ 72 BOWSTRING SP-Series Tables SLOPED BOWSTRING SLOPED ARCH Standard Specification ARCH LIABILITY STATEMENT The data published in this catalog has been developed using recognized engineering principles and is intended for general information only. Although the data shown is believed to be accurate, New Millennium Building Systems does not assume any liability or obligation of any kind or nature arising from or related to the data provided herein and/or its use. Applicability of the products and the accuracy of the data should be assessed by a licensed professional engineer or architect to determine the suitability for the intended application. New Millennium Building Systems’ Standard Terms and Conditions shall supersede any statements to the contrary contained herein. Introduction Uplift your design ideas 40,000 ways to change the shape of architecture. This catalog was developed in response to the growing demand for new structural design ideas and innovative rooflines that are only possible using “special profile” steel joists. Special Profile Joists To meet the aspirations of both architects and engineers, we have vastly expanded the previous range of published weight table specifications for the four basic special joist profiles: gable, bowstring, scissor, and arch. This development has eased the way for the evaluation and specification of many thousands more combinations of steel joist profiles that were heretofore not practically supported by the specification tables. With this catalog as your guide and our engineering teams at your service, you now have access to the following: •Over 40,000 engineering design specifications across four basic profiles •Engineers can now more feasibly and practically specify unique steel architecture SP-Series Design •Tables include bridging information, bearing seat depth and other key information •Online joist specification “tools” make specification even easier and faster Standard Specification SP-Series Tables •Online tools are available as mobile apps for Android and iOS devices As more architects have learned about the design flexibility of gable, scissor, bowstring and arch joist profiles, they have used variations and even combinations of these profiles to uplift distinctive building designs. 2 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Shipping Considerations Introduction Delivery coordination of your project. We ship special profile steel joists to all regions of the country and are always mindful of related considerations, such as trailering length and erection site constraints. We will collaborate on these important considerations to further assure the cost-minimized success of the project. •Coordination on erection site access and joist routing on site are often based on joist size and length, including whether profile dimensions must be modified in advance to minimize delivery costs. Related considerations include whether the joists can be shipped and erected in one piece or shipped in shorter sections for field splicing. •Coordination extends to roadway considerations and meeting any state requirements regarding over-length or over-width material, types of escorts and route surveys. Special Profile Joists •Coordination on material delivery schedules prior to shipping to ensure the erection crew has the proper equipment and is ready to unload when the truck arrives. NMBS engineering can provide joist weights and bundle weights to assist in this planning. •Sufficient time should be allowed for safe unloading. Special profile joists can take more time to unload than standard steel joists, due to their often-unusual shapes and dimensions. •The safe erection of steel joists is guided by the OSHA Steel Erection Standard Part §1926. This information is published in our Steel Joists and Joist Girders catalog. SP-Series Design SP-Series Tables Standard Specification Hundreds of steel building projects feature special profile steel joists. New Millennium can deliver anywhere in the country. Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 3 Introduction Together, let’s build a better steel experience. New Millennium’s competitive advantage is flexibility. As our customers nationwide have discovered, we engineer winning relationships, success stories that continue to build America. Our uniquely flexible engineering and manufacturing business model enables us to take the project owner’s point of view: delivering higher total-project performance, for less total-project cost. You can count on us for the experience, products, services, and nationwide locations that will build your business... Special Profile Joists •Value engineered total-project cost management •Flexible approach to steel joist and metal decking supply •Experienced developers of special profile steel joists •Leading, most experienced providers of BIM/IPD projects SP-Series Design •Nationwide locations for local supply and support QUALITY ASSURANCE SP-Series Tables New Millennium is a Steel Joist Institute (SJI) member company, fully certified to manufacture K, LH and DLH-Series Steel Joists, and Joist Girders. New Millennium is also a Steel Deck Institute (SDI) member company, fully certified to manufacture roof deck, form deck, and composite floor deck. • New Millennium products meet FM, UL and ULC requirements. • Welders are certified in accordance with AWS D1.1 and D1.3. • The Indiana and Nevada facilities meet CSA Standard W47.1 in Division 2 for open web joists. • The Indiana facility is certified in accordance with the requirements of the current IBC/Michigan Building Code, Chapter 17, Section 1705, Paragraph 2.2. • The Florida facility is certified in accordance with the requirements of the Miami-Dade County, Florida Building Code, Article IV, Chapter 8. Standard Specification • The Arkansas and Florida facilities are certified in accordance with the Houston, Texas Building Code, Section 1704.2.2. • The Nevada and Mexico facilities are certified in accordance with the requirements of Clark County, LA City, IAS (pending). 4 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Nationwide Support Introduction New Millennium is your nationwide resource for design, manufacturing, and delivery of structural steel joists, and steel roof and floor decking. Special Profile Joists SP-Series Design FALLON JUAREZ FALLON FALLON HOPE JUAREZ JUAREZ BUTLER HOPE FALLON BUTLER JUAREZ MANUFACTURING LOCATIONS: HOPE SALEM BUTLERFacility Indiana 1992 NW Bascom Norris Drive Lake City, FL 32055 Phone: (386) 466-1300 Fax: (386) 466-1301 SALEM Facility Virginia HOPE Facility Arkansas 100 Diuguids Lane LAKE CITY Post Office Box 3400 Salem, VA 24153 Phone: (540) 389-0211 Fax: (540) 389-0378 3565 Highway BUTLER 32 North Hope, AR 71801 Phone: SALEM (870) 722-4100 Fax: (870) 722-4245 LAKE CITY FALLON JUAREZ FALLON Facility Nevada JUAREZ Mexico Facility 8200JUAREZ Woolery Way Carr. Panamericana 9920 HOPE Fallon, NV 89406 HOPECol. Puente Alto BUTLER HOPE Phone: (775) 867-2130 C.P. 32695 BUTLER Fax: (775) 867-2169 Cuidad Juarez Chihuahua BUTLER SALEM SALEM Mexico LAKE CITY SALEM LAKE Phone: CITY (915) 298-5050 LAKE CITY Fax: (915) 298-4040 SP-Series Tables 6115 County SALEMRoad 42 Butler, IN 46721 LAKE CITY Phone: (260) 868-6000 Fax: (260) 868-6001 LAKE CITY Florida Facility FALLON To quickly identify the sales representative that services your area, log on to www.newmill.com/contactus.html Standard Specification Industry-leading 3D BIM design • State-of-the-art manufacturing • Nationwide delivery and support • Steel joists and metal decking Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 5 Product Flexibility Introduction Assure the winning success of your project, with our full range of structural steel roofing and flooring systems development. For faster and easier specification, start with our convenient web-based or mobile app design tools. See page 6 of this catalog or visit www.newmill.com/digital-tools STANDARD STEEL JOISTS Special Profile Joists Joist products include K, LH and DLH Series joists and joist girders, and CJ Series joists (Composite Joist). Joists can be furnished as a single-piece up to 15 feet deep and up to 125 feet long, depending on location and shipping restrictions. All are produced in accordance with the specifications of the Steel Joist Institute. FLEX-JOIST ™ TENSION-CONTROLLED STEEL JOIST DESIGN SP-Series Design Flex-Joist™ tension controlled steel joist design results in a joist that characteristically displays both higher strength levels and large inelastic deformations prior to collapse. The result is a roof or floor framing system with improved strength, an improved reliability index, and improved sensory alert to overload prior to collapse. Flex-Joist™ tension-controlled steel joist design is ideally suited to electronic monitoring of deflection and/or strain for early warning of high loads, if desired. This can allow time for building evacuation, load removal, and/or shoring to prevent collapse. Although electronic monitoring is not provided by NMBS, we can help coordinate requirements with your electronic monitoring supplier. SP-Series Tables SPECIAL PROFILE STEEL JOISTS Unique roofline designs are now practical and economical using special profile steel joists, due to our development of engineering specifications enabling over 40,000 special profile steel joist design possibilities. We manufacture a complete range of special profile steel joist products, including bowstring, arched, scissor, doublepitched, and single-pitched steel joists. METAL DECKING Standard Specification Roof and floor metal deck options include B deck, N deck, form deck and composite deck. Engineered to the application, our decking systems are certified to address performance requirements related to such factors as wind uplift, fire resistance and noise reduction. 6 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Service Flexibility Introduction Elevate the long-term success of your business with our proactive approach to your project needs. Special Profile Joists SP-Series Design Bring us in early on the project to help achieve your architectural vision, while holding the line on structural execution and related project costs. We can show you new design solutions made possible by our leading development of over 40,000 new engineering specifications in the discipline of special profile steel joist design. We participate in BIM based projects using our new Dynamic Joist® digital design component. The component is available as a free, downloadable add-on for Tekla Structures. New Millennium supports the Industry Foundation Classes (IFC) standard for data transport and the sharing of our component across various BIM platforms. ENGINEERED COST REDUCTIONS DYNAMIC MANUFACTURING & DELIVERY We remove a chain reaction of project costs, starting with reduced steel tonnage and ending with lower on-site labor costs for handling, lifting and erection. Our approach to cost-accountable engineering can shorten project timelines and prevent delayed occupancy or lost retail revenues. Our dynamic manufacturing can adjust to any project timeline or changing erection site needs, including staged and just-in-time deliveries. Just tell us what you need and when you need it. Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification BIM DESIGN COLLABORATION SP-Series Tables ARCHITECTURAL SOLUTIONS 7 Introduction Digital Specification Tools Discover the easiest way to specify special profile steel joists: www.newmill.com/digital-tools •Easier and faster specification •Helpful cost-saving guidelines and options SP-Series Design Special Profile Joists •Mobile app for on-the-go convenience •Complete range of digital design tools: – Standard steel joists and steel Joist Girders – Special profile steel joists – Steel roof and floor decking 3D BIM-BASED DESIGN WEB-BASED AND MOBILE SPECIFICATION TOOLS Our Dynamic Joist component is the leading choice for BIM-based steel joist 3D design. Whether you’re in the office or out in the field, New Millennium has you covered. Introducing the industry’s first complete set of digital specification tools. To further simplify and accelerate the steel package design process, New Millennium has packed the power of our specification catalogs into advanced web and mobile applications. SP-Series Tables ® Standard Specification New Millennium pioneered IPD (integrated project delivery) with steel joists by making BIM-based process management a reality. Since early 2010, Dynamic Joist® has enhanced design collaboration in real-world projects throughout North America. Available as a FREE download on our website. Get yours today! 8 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Built upon our expertise in steel joist and metal deck engineering, and backed by our database of load and weight tables, this toolset will prove to be your handy go-to resource. You will find everything you need... from standard steel joists and girders, to our industry-leading special profile steel joist designs, to a wide range of roof, form, and composite floor decking. Our commitment to building a better steel experience is focused on you. Log on to our website and start using these tools today. LEED Information Introduction LEED (Leadership in Energy & Environmental Design) New Millennium is a member of the US Green Building Council, the governing body of LEED, the most widely recognized and used green building program around the globe. New Millennium monitors changes in the LEED rating system as well as other environmental rating systems and can provide documentation on recycled content and regional material information depending on project location. Special Profile Joists Current New Millennium LEED information can be found under the DOWNLOADS tab on our website at www.newmill.com. Scan the QR-code at the right for a quick link to our detailed LEED information page, including downloadable PDFs regarding our current recycled content. LEED® Green Building Rating System™ What’s driving green building? The growth of green building is being expedited by three factors: Why build green? Green buildings consume less energy and fewer resources. In comparison to the average commercial building, green buildings: Source: GSA Public Buildings Service (2008). Assessing Green Building Performance: A Post Occupancy Evaluation of 12 GSA Building. NEW MILLENNIUM RECYCLED CONTENT New Millennium steel joists and metal decking products are fabricated from steel manufactured at mini-mills using scrap steel. Therefore, our product can be used towards points under the Materials and Resources Credit 4 which covers Recycled Content. Under MR Credit 4 you can obtain up to 2 points towards LEED certification if you use materials with recycled content such that the postconsumer recycled content plus 1/2 of the preconsumer content constitutes at least 10% (1 point) or 20% (2 points), based on cost, of the total value of the materials in the project. Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification • Consume 26% less energy • Have 13% lower maintenance costs • Have 27% higher occupant satisfaction • Produce 33% less greenhouse gas emissions SP-Series Tables • Unprecedented level of government initiatives • Heightened demand for green construction • Improvements in sustainable materials The LEED certification system is organized into five environmental categories: Sustainable Sites (SS), Water Efficiency (WE), Energy and Atmosphere (EA), Materials and Resources (MR) and Indoor Environmental Quality (IEQ). An additional category, Innovation in Design (ID), addresses sustainable building expertise as well as design measures not covered under the five environmental categories. The number of points the project earns determines the level of LEED Certification the project receives. SP-Series Design The LEED Green Building Rating System™ is a voluntary, consensus-based standard to support and certify successful green building design, construction and operations. LEED certification is available for all building types including new construction and major renovation, schools, healthcare, retail, homes, neighborhoods, core and shell, commercial interiors and even existing buildings. 9 Introduction Special Profile Steel Joists, SP-Series AVAILABILITY SPECIAL PROFILE STEEL JOISTS, SP-SERIES SPECIAL PROFILE STEEL STEEL JOISTS, JOISTS, SP-SERIES SP-SERIES There are an endless number of possibilities for joist profiles, SPECIAL PROFILE SPECIAL PROFILE STEEL JOISTS, SP-SERIES GENERAL INFORMATION loadings, andINFORMATION applications. In order to make this catalog a GENERAL GENERAL GENERAL INFORMATION There areINFORMATION anendless endlessnumber numberofofpossibilities possibilities forjoist joist more useful and focused publication, four distinct for profiles There are an There are an endless number of possibilities for joist There are an and endless number of The possibilities for are: joist profiles, loadings, andapplications. applications. Inorder order tomake make this profiles, loadings, and In this were identified made the focus. four to profiles profiles, and applications. In make this profiles, loadings, andand applications. In order order to to make this catalogaloadings, amore moreuseful useful andfocused focusedpublication publication four distinct catalog four distinct Gable, Bowstring, Scissor, and Arch. Most SP-Series joists are catalog more useful and focused publication four distinct catalog moreidentified useful and focused publication four distinct profilesaawere were identified and made thefocus. focus. The four profiles and made the The four either one of these four types, a variation of one type, or a profiles were identified and made the focus. The four profiles were identified and made the focus. TheMost four profilesare: are:Gable, Gable, Bowstring, Scissor, andArch. Arch. Most profiles Bowstring, Scissor, and profiles are: Gable, Bowstring, Scissor, and Arch. Most combination of one or more types. When specifying SP-Series profiles are: Gable, Bowstring, Scissor, and Arch. Most SP-Series joists are either one of these four types, SP-Series joists are either one of these four types, a a GABLE SP-Series joists are either one these four aa SP-Series joists are either one of these four types, variation onetype, type, combination onetypes, more joists, communication between the of specifying professional variation ofof one orora acombination ofof one orormore variation of one type, or a combination of one or more variation of one type, or a combination of one or more types. When specifying SP-Series joists, communication types. When specifying SP-Series joists, communication and NMBS is key to success. Standard Specification SP-Series Tables SP-Series Design Special Profile Joists types. When specifying SP-Series joists, communication types. When specifying SP-Series joists, communication between thespecifying specifyingprofessional professional andNMBS NMBS thekey key between the and isisthe between the specifying professional and NMBS key between the specifying professional and NMBS is the the key to success. to success. SP-Series joists are available with either underslung isor square to to success. success. ends. Due to the limitations of depth and span inherent in special SP-Seriesjoists joistsare areavailable availablewith witheither eitherunderslung underslungoror SP-Series profiles, it is recommended that the owner’s representative SP-Series joists are available with underslung or SP-Series joists are available with either either underslung or squareends. ends. Due thelimitations limitations depth andspan span square Due toto the ofofdepth and square ends. Due the limitations of depth span contact NMBS early in the cost square ends. Due to to the design limitations ofConsiderable depth and and span inherent special profiles, recommended that the inherent ininspecial profiles, it itisisstage. recommended that the inherent in special profiles, itit is recommended that the inherent in special profiles, isNMBS recommended that the owner’s representative contact earlyin inthe the design savings may be recognized by addressing design and shipping owner’s representative contact NMBS early design owner’s representative contact NMBS early in the design owner’s representative contact NMBS early inmay therequire design stage. Considerable cost savings may berecognized recognized stage. Considerable cost savings may be byby issues early in the design process. SP-Series joists stage. Considerable cost savings may be recognized by stage. Considerable cost savings may be recognized by addressing design and shipping issues early in the design addressing design and shipping issues early in the design horizontal or vertical field splicing involving installation cost addressing design shipping issues early in the addressing design and andjoists shipping issues earlyhorizontal in the design design process. SP-Series SP-Series joists may may require horizontal process. require oror at the job site. To ensurejoists a fair may and accurate process, process. SP-Series require horizontal or process. SP-Series joists may requirebidding horizontal or vertical field splicing involving installation cost thejob job vertical field splicing involving installation cost atatthe these issues should beinvolving identified andbidding resolved prior to bid. vertical splicing installation cost at job vertical field splicing involving installation cost at the the job site.To Tofield ensure fair andaccurate accurate bidding process, these site. ensure a afair and process, these site. To ensure fair and process, site. Tocalculations ensure abe fair and accurate accurate bidding process, these issues shouldabe identified and resolved prior to bid. Design prepared by a bidding professional engineer issues should identified and resolved prior tothese bid. issues be and prior to issues should be identified identified and resolved prior to bid. bid. Designshould calculations a professional engineer Design calculations prepared bybyaresolved professional engineer registered in the state ofprepared manufacture are available for NMBS Design calculations prepared by engineer Design calculations prepared by aa professional professional engineer registered thestate state manufacture areavailable available for registered ininthe ofofmanufacture are for SP-Series joists. registered in state registered in the the joists. state of manufacture manufacture are are available available for for NMBSSP-Series SP-Series joists.of NMBS NMBS NMBS SP-Series SP-Series joists. joists. Experienced NMBS design personnel equipped with Experienced NMBS NMBS design design personnel personnel equipped equipped with with Experienced sophisticated design software on on staff toequipped help with the Experienced NMBS design personnel with Experienced NMBS designare personnel equipped with sophisticated design software are staff to help with the sophisticated design software are on staff to help with the design ofofSP-Series joists or joist girders. Instaff a matter minutes, sophisticated design software are on to with sophisticated design software are on staff toInhelp help with the the design ofSP-Series SP-Series joists joist girders. In matter design joists oror joist girders. aofamatter ofof design of SP-Series joists or joist girders. In matter design ofNMBS SP-Series joists or joist girders. Inand matter of minutes, NMBS can design SP-Series joist e-mail NMBS can designcan a SP-Series and e-mail aaaand STAAD orof minutes, design a ajoist SP-Series joist e-mail aa minutes, NMBS design aapreliminary SP-Series joist and e-mail minutes, NMBS can design SP-Series joist and e-mail STAADfile orAutoCAD file nocharge. charge. This preliminary STAAD or file atat no This preliminary AutoCAD atAutoCAD nocan charge. This design can give youaa STAAD or AutoCAD file at charge. This preliminary STAAD or give AutoCAD file at no no This preliminary design can giveyou youthe the head start thatyou you need gaina a design can head start that need totogain the headcan start that you need to gain acharge. competitive edge. design you design can give give you the the head head start start that that you you need need to to gain gain aa competitive edge. competitive edge. competitive competitive edge. edge. GEOMETRY GEOMETRY GEOMETRY GEOMETRY GEOMETRY The dimensions shown theSP-Series SP-Series profilediagrams diagrams The dimensions shown ononthe profile The dimensions shown on on the SP-Series profileprofile diagrams to the The dimensions the diagrams The dimensions shown the SP-Series SP-Series profilebe diagrams tothe the rightand andshown onthe theon following pageshould should beclearly clearly to right on following page right and in the following page should be clearly shown and to the on the following page be toshown the right right and onon thethe following page should should be clearly clearly andand noted on the construction documents. Web shown and noted construction documents. Web noted in the construction documents. Web layouts in SP-Series shown and noted on the construction documents. Web shown noted on the construction documents. Web layoutsand SP-Series joists varygreatly greatly depending layouts ononSP-Series joists vary depending onon layouts SP-Series joists vary greatly depending layouts on SP-Series joists vary web greatly depending on joists varyon greatly depending on geometry andlayouts loading. Special geometry and loading. Special web layouts mayon be geometry and loading. Special may be geometry and loading. Special layouts may be geometry and loading. Special web layouts may for be specified on the the contract documents for architectural web layoutson may be specified on the web contract documents specified contract documents for architectural specified the documents for specified on the contract contract documents for architectural architectural needs ororon compatibility (e.g. duct clearances). Unless needs compatibility (e.g. duct clearances). Unless architectural needs or compatibility (e.g. duct clearances). needs or (e.g. clearances). Unless needs or compatibility compatibility (e.g. duct duct clearances). Unless specifically notedororrequested, requested, NMBS willprovide provide specifically noted NMBS will anan Unless specifically noted or requested, NMBS will provide an specifically or NMBS provide an specifically noted or requested, requested, NMBS will provide an economicalnoted webgeometry geometry thatmeets meets thewill requirements economical web that the requirements ofof economical web geometry that meets the the requirements of this economical web geometry that meets of economical web geometry that meets the requirements requirements of thisspecification specification andthose those contained inthe thecontract contract this and contained in this specification and those contained in contract specification and those contained inlayouts the contract documents. this specification and those contained in the contract documents. When special web layouts arethe required for documents. When special web are required for documents. special web layouts are required for documents. When special web layouts areand required for anyreason, reason,When they should clearly shown and noted on When special web layouts are required, they should be clearly any they should bebe clearly shown noted on any reason, they be shown any reason, they should be clearly clearly shown and and noted noted on on thecontract contract documents. the documents. shown and noted in should the contract documents. the the contract contract documents. documents. The old adage “deeper cheaper” true when when The old adage “deeper isis cheaper” isis considering true The oldoldadage “deeper is cheaper” is true when The “deeper is is when The old adage adage “deeper isIt Itcheaper” cheaper” is true true when considering SP-Series joists. isalso alsousually usually more cost considering SP-Series joists. is more cost SP-Series joists. It is fewer also usually more cost effective to considering joists. ItIt is also usually more cost considering SP-Series joists. iswith also usually more cost effectivetotoSP-Series specifyfewer joists, withincreased increased spacing, effective specify joists, spacing, specify fewer joists, with increased spacing, and therefore effective to specify fewer joists, with increased spacing, effective to specify fewer joists, with increased spacing, and therefore heavier, compared to more numerous, and therefore heavier, compared to more numerous, and therefore heavier, compared to more heavier, compared to more numerous, lighter joists atnumerous, narrower and therefore heavier, compared toSP-Series more numerous, lighter joistsatat narrower spacing. joistsare are lighter joists narrower spacing. SP-Series joists lighter joists at narrower spacing. SP-Series joists lighter joists at narrower spacing. SP-Series joists are are provided with no camber unless otherwise specified spacing. provided with no camber unless otherwise specified inin provided with no provided with no camber camber unless unless otherwise otherwise specified specified in in thecontract contract documents. the documents. the contract the SP-Series contract documents. documents. All joists are provided with no camber unless OFFSET GABLE SCISSOR COMPOUND SCISSOR OFFSET COMPOUND SCISSOR otherwise specified in the contract documents. 66 66 10 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Special Profile Steel Joists, SP-Series BOWSTRING Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 11 77 77 Standard Specification OFFSET COMPOUND ARCH SP-Series Tables COMPOUND ARCH SP-Series Design ARCH Special Profile Joists OFFSET BOWSTRING DESIGN The specifying has has several thingsthings to consider The specifyingprofessional professional has several things to consider consider DESIGN The specifying professional several to The specifying professional has several things to when specifying a SP-Series joist. The specifying when specifying SP-Series joists. The specifying professional when specifying a SP-Series joist. The specifying The specifying professional has several things to consider consider when specifying aa all SP-Series joist. The specifying professional is responsible for providing providing all loads for which iswhen responsible forresponsible providing loads for which theloads joist or professional is for all for which specifying SP-Series joist. The specifying professional is responsible for providing all loads for which the joist or joist girder must be designed. NMBS can help the joist joist mustNMBS be NMBS joist girderormust designed. can help identify andcan professional isbegirder responsible for designed. providing all loads for help which the joist or joist girder must be designed. NMBS can identify and suggest areas for review and value engineering identify and suggest areas for review and value engineering the joist or for joist girder be designed. NMBS can help help suggest areas review and must value engineering on SP-Series identify and suggest areas for review value engineering on SP-Series joists to to insure properand load development, on SP-Series joists insure proper load development, identify and suggest areas for review and value engineering joists to insure proper load development, analysis, and on joists design to insure proper load analysis, and structural structural design for any any project. analysis, and for project. on SP-Series SP-Series to insure proper load development, development, structural design forjoists any project. analysis, and structural design for any project. analysis, and structural design for any project. WIND LOADS LOADS WIND WIND LOADS WIND LOADS Design of structures to to resist resist wind wind load load in in combination combination with with WIND LOADS Design of structures Design of structures to resist wind load in combination Design of structures to resist wind load in combination other loads is required by every building code. Wind load other loads is required by every building code. Wind load Design of structures to resist wind load in combination with with other loads every building code. Wind load alone creates both lateralby wind forces andcode. uplift wind forces with other loadsis isrequired required by every building Wind alone creates both lateral wind forces and uplift wind forces other loads is required by every building code. Wind load alone creates both lateral wind forces and uplift forces on structure. The uplift wind forces must be resisted by the load creates both lateral forces andmust uplift forces onwind a by on aa alone structure. The uplift wind forces be resisted the alone creates both lateral wind forces and uplift wind forces on a structure. The uplift wind forces must be resisted by the primary and secondary roof support members. Both types of primary and roof support members. Both types structure. The secondary lateral forces and uplift forces on abe structure on a structure. The uplift wind forces must resisted by of the primary and secondary roof support members. Both types forces may or may not involve roof deck, standard joists, forces may or may not involve roof deck, standard joists, primary and secondary roofand support members. Both types of of must be resisted by the primary secondary roof support forces may or may not involve roof deck, standard joists, joist girders, or SP-Series joists provided by NMBS. NMBS. joist girders, or provided by forces may orSP-Series may not joists involve roofnot deck, standard joists, members. Both types of forces may or may involve roof joist girders, or joists provided by NMBS. joiststandard girders,joists, or SP-Series SP-Series joists provided byprovided NMBS. deck, joist girders, or SP-Series joists The lateral lateral wind wind moment moment or or lateral lateral forces forces are are best best provided provided The byThe NMBS. lateral wind lateral are provided to NMBS in terms terms of “Wind “Windor Moment” in units units ofbest foot-kips or to NMBS in of Moment” in of foot-kips or The lateral wind moment moment or lateral forces forces are best provided to NMBS in terms of “Wind Moment” in units of foot-kips “Wind Axial Load” in units of kips. As end moments and or oror “Wind Axial in Load” of kips. As end moments and to NMBS termsin ofunits “Wind Moment” in units of foot-kips or “Wind Axial Load” units of As moments The lateral windact moment or lateral forces are end best provided axial forces act inin combination with other loads, and (e.g.or axial forces in other loads, (e.g. “Wind Axial Load” incombination units of kips. kips.with As end moments and or act in with other loads, uniform and continuity moments), coordination toaxial NMBSforces ingravity terms ofand “Wind Moment” in units foot-kips uniform gravity continuity moments), coordination axial forces act in combination combination with of other loads, (e.g. (e.g. gravity continuity coordination between the specifying professional and NMBSand is crucial. crucial. oruniform “Wind Axial Load” and in units of kips. As moments), end moments between the specifying professional and NMBS is uniform gravity and continuity moments), coordination between the specifying professional and is This ensures that the building building codeloads, specified combinations This ensures that the code specified combinations between thein specifying professional and NMBS is crucial. crucial. axial forces act combination with other (e.g.NMBS uniform This ensures that the building code specified combinations are properly applied. Clear instructions on the contract are properly applied. Clear instructions on the contract This ensures that the building code specified combinations gravity and continuity moments), coordination between are properly applied. Clear instructions on the contract drawings and, better better still, still, contact with NMBS NMBS during the drawings and, contact during the arespecifying properly applied. Clear instructions the contract the professional and NMBS iswith crucial toon ensure drawings and, better still, contact with NMBS during the design process is advised. design process is advised. drawings and, better still, contact with NMBS during the that the building code specified combinations are properly design process is advised. design process is advised. applied.isClear on NMBS the contract documents and,Uplift” in Uplift bestinstructions provided to to in terms terms of “Net “Net Uplift is best provided NMBS in of Uplift” in better still, contact with NMBS during the design process Uplift is best provided to NMBS in terms of “Net Uplift” units ofis pounds per square square foot and and shown on “Net plan upliftin units of pounds per aa plan uplift Uplift best provided to foot NMBS inshown terms on of Uplift” in is advised. units of pounds per square foot and shown on a plan layout. These loads are then applied to the affected layout. loads are then to on thea affected units ofThese pounds per square foot applied and shown plan uplift uplift layout. loads are then to the members according to the the tributary area. Uplift Uplift design may members according to area. may layout. These These loads aretributary then applied applied to design the affected affected Uplift is bestaccording provided toto NMBS inbridging terms ofarea. “Net Uplift” in bottom members the tributary Uplift design also involve additional rows of bridging or joist girder bottom also involve additional rows of or joist girder members according to the tributary area. Uplift design may may also rows of bridging or joist girder bottom units poundsadditional per squarethose foot and shown onfor a plan uplift chord braces beyond those required for normal erection chord braces beyond required normal erection alsoofinvolve involve additional rows of bridging or joist girder bottom chord braces those required for normal stability. layout. loadsbeyond are then applied the affected stability. chordThese braces beyond those to required formembers normal erection erection stability. according to the tributary area. Uplift design may also involve stability. On sloped roofs wind or load actingbottom on the the roof will create create On sloped roofs wind load on roof will additional rows of bridging joistacting girder chord braces On roofs load acting on the roof will create inward pressure onwind the windward side of the roof that is inward pressure on the windward roof is On sloped sloped roofs wind load actingside on of thethe roof willthat create beyond those required for normal erection stability. inward pressure on the windward side of the roof that additive to normal gravity loading and outward pressure on additive normal gravity andside outward pressure onis inward topressure on the loading windward of the roof that is additive to normal gravity loading and outward pressure the leeward side that opposes the normal gravity loading. the leeward side that opposes the normal gravity loading. Onadditive sloped roofs, wind gravity load acting on the roofoutward will create to normal loading and pressure on on the side that opposes the normal loading. Both loading conditions haveside effects on gravity the isresulting resulting Both loading conditions have effects on the the leeward leeward that opposes the gravity loading. inward pressure side on the windward of normal the roof that Both loading conditions have effects on the resulting member forces and subsequent design. The specifying member forces and subsequent design. The specifying Both loading conditions have effects on the resulting additive to normal gravity loading and outward pressure onspecifying member forces and subsequent design. The professional is reminded reminded to clearly clearly communicate communicate such loads professional is to such loads member forces and subsequent design. The specifying the leeward side that opposes the normal gravity loading. professional is reminded to clearly communicate such toprofessional NMBS. to NMBS. is reminded to clearly such loads loads Both loading conditions have effects on thecommunicate resulting member to NMBS. to NMBS. forces and subsequent GRAVITY LOADS design. The specifying professional is GRAVITY LOADS reminded to clearly communicate loadssnow to NMBS. GRAVITY LOADS Design of structures structures to resist resistsuch gravity load, dead dead load, load, GRAVITY LOADS to Design of gravity snow load, Design of structures to resist gravity snow dead load, and live load in combination with other loadsload, is required required by and live load in combination with other loads is by Design of structures to resist gravity snow load, dead load, GRAVITY LOADS and live load in combination with other loads is required every building code. When joists are part of the lateral force every When joists areother part of the is lateral forceby and building live loadcode. in combination with loads required by every building code. When joists are part of lateral force resisting system, they may also resist axial loads, end resisting system, they may also resist loads, Design structures to resist gravity snow load, dead load, everyof building code. When joists are partaxial of the the lateral end force resisting they may also resist axial loads, end moments, or perform other structural requirements as moments, or perform structural requirements resisting system, theyother mayother also resist axial by loads, as end and live loadsystem, in combination with loads is required moments, or perform other structural requirements determined by the design professional. determined bycode. design professional. moments, ortheperform other structural requirements as as every building determined determined by by the the design design professional. professional. The uniform snow load inlateral combination with the the dead dead load load The snow combination with Whenuniform joists are part load of thein force resisting system, The uniform snow load combination dead load (including estimated joistsin self-weight) iswith bestthe provided to (including estimated joists self-weight) is best provided to The uniform snow load in combination with the dead load they may alsoestimated resist axialjoists loads, self-weight) end moments,isorbest perform (including provided NMBS as part of the the designation in units of pounds per NMBS as part of the the designation in units of pounds perto (including estimated joists self-weight) is best provided to NMBS as part of the the designation in units of pounds NMBS as part of the the designation in units of pounds per per Introduction SPECIAL PROFILE PROFILE STEEL STEEL JOISTS, JOISTS, SP-SERIES SP-SERIES SPECIAL SPECIAL PROFILE STEEL JOISTS, DESIGN SPECIAL PROFILE STEEL JOISTS, SP-SERIES SP-SERIES DESIGN DESIGN Introduction Special Profile Steel Joists, SP-Series other structural requirements as determined by the design professional. The uniform snow load in combination with the dead load (including estimated self-weight) is best provided to NMBS as part of the SP-Series designation in units of pounds per linear foot. Refer to the design examples on pages 17 through 23 for further explanation. There are also several abbreviated examples on pages 100 through 103. Special Profile Joists On steep sloped or curved roof profiles more complex load combinations must be considered. Depending on the slope, snow drift may be a consideration or live load reduction may be permitted. Unbalanced loading may also create critical stresses. Coordination between the specifying professional and NMBS becomes crucial to ensure that code specified combinations are properly applied. Clear instructions in the contract documents and, better still, personal contact with NMBS during the design process is advised. SP-Series Design While it is not the purview of this document to dictate design loads, there are several items that must be drawn to the specifying professional’s attention to ensure SP-Series joist designs are consistent with applicable building codes and specifications. Building codes vary in minimum load and load combination requirements. Model codes, such as the latest International Building Code (IBC) and the widely referenced ASCE/SEI 7 Minimum Design Loads for Buildings and Other Structures, contain complex sections dictating the application of loads to Standard Specification SP-Series Tables See Section 906 – HOW TO SPECIFY SPECIAL PROFILE JOISTS 12 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools all components of buildings and other structures. Attention is drawn to the fact that the application of loads to sloping, curved, and pitched roofs that utilize SP-Series joists must be concerned with loads on horizontal and vertical projections, windward and leeward wind and snow loads, uniform and drifting snow, unbalanced loading, and myriad other possible loads specific to the geometry, geographic location, and structural functions explicit to the SP-Series joist design requirements. The intent of the weight tables in this publication is to provide the specifying professional approximate weights, bridging requirements, seat depths, and other design information when appropriate for special profile joists. This information is to serve as a basis for comparison of alternative designs and value engineering purposes. The weight tables were generated based on various uniform loadings on a select array of Special Profile Joists, SP-Series, geometries. In using the weight tables, the specifying professional must use sound judgment in relating actual loading conditions to a comparable equivalent uniform load. Design information should be clearly shown in the contract documents by the specifying professional. Load diagrams should convey load combinations, uniform load and unbalanced load requirements in addition to the total, live, and net uplift specified by the designation. Concentrated load values and locations should also be shown and noted by type and by applicable load case where appropriate. Special Profile Steel Joists, SP-Series Introduction Special Profile Joists SP-Series Design FIRE RATINGS FABRICATION & DELIVERY NMBS SP-Series joists are made entirely of steel and are noncombustible. They qualify in roof construction for some uses in construction types that the model building codes identify as Type IA, IB, IIA, IIB, IIIA and IIIB. Specifying professionals should consult applicable local codes for details and other requirements for the entire roof system. NMBS production facilities have been specifically designed and equipped to produce SP-Series joists. This allows NMBS to maintain the high quality our customers expect and provide cost advantages through state-of-the-art design and manufacturing facilities. SP-Series Tables Standard Specification Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 13 Introduction SP-Series Design HORIZONTAL REACTIONS the specifying professional and clearly indicated in the contract The behavior of some SP-Series profiles, such as Scissor or Arch, documents. To facilitate proper design for this condition and to may cause a horizontal reaction to be applied to the supporting be certain that code specified requirements are properly satisfied, structure. When joists with upwardly curved or sloped bottom coordination between the specifying professional and NMBS chords deflect under load, they either displace at the bearing is crucial. points or induce a horizontal thrust force at the supports. The magnitude of the thrust force imparted to the support is a les, such asfunction Scissor or Arch, maythecause reaction to be applied to the of the stiffness of the joist, stiffness ofathehorizontal support, A second design option is to design the end anchorage supports upwardly curved or sloped bottom chords deflect load, they eithercondition). displace at option may and the attachment conditions. The chart below shows the linearunder as fixed at each end (pin-pin This design interactive between theThe two theoretical conditions. decrease the weight joist. However, horizontal thrust tal thrust force at relationship the supports. magnitude of the thrust forceof the imparted to the the at the end anchorage of the joist can be quite of the joist, the stiffness of the support, and the attachment conditions. The chart large and the From a design standpoint, one option is to provide a slip resisting structure or tie must be designed by the specifying ionship between two connectionthe at one end,theoretical which eliminatesconditions. the bearing restraint professional for the thrust force. Once the joist end attachment and the resulting horizontal thrust force (pin-roller condition). This has been made, the combined horizontal stiffness of both the option eliminates the possibility for the joist to transmit chord supportingthe structure and therestraint joist must be large enough to s to provide a slip connection at one end, which eliminates bearing and develop the required horizontal thrust at the joist end anchorage. axial forces to the supporting structure at the slip-bearing end. n-roller condition). This option eliminates the possibilityThefor the joist to transmit chord required stiffness can be generated by means of a braced For this condition, the specifying professional should coordinate re at the slip-bearing end.deflection For this condition, the specifying should frame, a tension professional tie, or some other structural mechanism. Once the allowable horizontal at the bearing with NMBS. clear instructions in thejoist contract documents and, better Diaphragm forces with collectedNMBS. into the joist chords must transfer flection at the bearing Diaphragm forcesagain, collected into the chords still, personal contact with a for NMBSboth design engineer through the pinned end of the joist seat. joist must of the joist seat. Consequently, joistConsequently, anchorage be designed the during the quote and design process is imperative for successful SP-Series anchorage must be designed for both the windward and leeward and roller forces. anchorage for this joist design. must be intentionally The pin andconditions roller anchoragenecessary conditions necessary for approach g professional and clearly indicated in the contract this approach must be intentionally designed and detailed by documents. To facilitate proper Special Profile Joists SPECIAL PROFILE STEEL JOISTS, SP-SERIES SP-Series Design tain that code specified requirements are properly satisfied, coordination between is crucial. Standard Specification SP-Series Tables gn the end end (pin-pin ecrease the zontal thrust an be quite tie must be onal for the chment has stiffness of oist must be d horizontal he required of a braced er structural ctions in the ll, personal r during the perative for generated using a uniform distributed load on a horizontal span. Therefore, the Discover the easiest way to specify special profile joists: es joist 14 designations should be calculated as distributed normal to the span. Loads www.newmill.com/digital-tools efined as horizontal or vertical. When the SP-Series joists’ span is sloping, or when SP-Series Design Introduction SPECIAL PROFILE STEEL JOISTS, SP-SERIES PROFILE STEEL JOISTS, SP-SERIES LOAD ADJUSTMENT FACTORS The load adjustment factors RpSPECIAL and Rs are independent of one another and must be applied to The load adjustment factors R and R are Special Profile Joists p s The SP-Series Weight Tables weretogenerated using a uniform the design loads in order accurately independent of one another and must determine be applied an to equivalent gravity load. Figures to the distributed load onuniform a horizontal Therefore, the uniform the design loads in total orderspan. to accurately determine an right show theSP-Series general theory for determining equivalent uniform total gravity load. Figures to the the loads specified in the joist designations should be uniform loadthewith whichtheory to enter the joist tables. right show general for determining the calculated as distributed normal to the span. Loads in design Design may be found the on pages 10 uniform examples with which tables. development areload generally definedtoasenter horizontaljoist or vertical. through Design 16. examples may be found on pages 10 When the SP-Series through 16. joists’ span is sloping, or when the top orderor to convert distributed loads chord isInpitched curved, one oruniform more adjustment factors are generated in design development to uniform loads In order to convert uniform distributed loads neededtabulated to convert inactual loads, w , to the designation loads, a the SP-Series Weight Tables,loads the generated in design development to uniform wd, used in the SP-Series designations. specifying professional must Weight first determine tabulated in the SP-Series Tables, the the maximum from must all applicable load cases. specifying moment professional first determine the The moment generally be best maximum from will all applicable cases. thethedesign Profile The first ofmaximum thesemoment adjustment factors, R , isload determination formoment the chord sizes ofp thebe joistthe The maximum will generally best Projection Ratio for chords the difference the since the and top accounts and bottom thebetween key factors determination for the chord sizesare of the joist design actual chord length and the straight line length along the span. in determining joist weight. since the top and bottom chords are the key factors The Profile Projection joist Ratioweight. comes in two varieties, Rpp and in determining the maximum moment is determined, the next Rpr, forOnce pitched chords and radius chords respectively. The step is to find the equivalent total uniform load (Wnext eqMOnce maximum moment is isdetermined, the purposeTL of thethewould Profile Projection to account forWhile dead ) that cause thisRatio maximum moment. step is to find the equivalent total uniform load (W eqMloads uniformly distributed on the actual length of the joist top this method does assume that the maximum uniform TL) that would cause this maximum moment. While moment occurs at the mid-span of the joist, it is chord, which will always be longer than the span length for this method does assume that the maximum uniform accurate for determining a joist self-weight, bearing SP-Series joists. occurs Calculating and mid-span applying the ratio enables moment at the of Rthe joist, it is p seat heights, and bridging requirements. NMBS accurate for determining a joist self-weight, bearing the specifying professional to easily determine the equivalent engineering availablerequirements. to assist withNMBS your seat heights,staff andis bridging uniformspecific load projected normal to the span. design needs. SP-Series Design engineering staff is available to assist with your specific design needs. After determining the equivalent uniform moment, The second adjustment factor, Rs, is the Slope Projection Ratio the and final step to adjust the uniform loads Afternext determining the is equivalent uniform moment, and accounts the difference in the horizontal span length . Once the step load is and with Rsfor the next and final is adjusted to adjust the the geometry uniform loads and thedesignation joist span as defined in Section 904.2 on page 95. R may be referenced in the SP-Series with Rs. Once the load is adjusted the geometry ands Weight Tables. The contain uniform selfis independent of themay profile shape and should be calculated designation betables referenced inthethe SP-Series weight, bearing seattables depth, bridging Weight The contain therequirements, uniform selfwhen the joist Tables. span is sloped. As seen on the right, applying and horizontal deflection requirements when weight, bearing seat depth, bridging requirements, Rs isolates the component of the uniform load normal to the applicable. and horizontal deflection requirements when The load adjustment factors Rp and Rs are independent of one another and must be applied to the design loads in order to accurately determine an equivalent uniform total gravity load. Figures to the right show the general theory for determining the uniform load with which to enter the joist tables. Design examples may be found on pages 17 through 23. Once the maximum moment is determined, the next step is to find the equivalent total uniform load (WeqM-TL) that would cause this maximum moment. While this method does assume that the maximum uniform moment occurs at the mid-span of the joist, it is accurate for determining a joist self-weight, bearing seat heights, and bridging requirements. NMBS engineering staff is available to assist with your specific design needs. After determining the equivalent uniform moment, the next and final step is to adjust the uniform loads with Rs. Once the load is adjusted, the geometry and designation may be referenced in 11 the SP-Series Weight Tables. The tables contain the uniform self-weight, bearing seat depth, bridging requirements, and 11 horizontal deflection requirements when applicable. Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification In order to convert uniform distributed loads generated in design development to uniform loads tabulated in the SP-Series Weight Tables, the specifying professional must first determine the maximum moment from all applicable load cases. The maximum moment will generally be the best determination for the chord sizes of the joist design since the top and bottom chords are the key factors in determining joist weight. SP-Series Tables span of the joist. The longitudinal component of this load applicable. translates into a uniform distributed axial load along the top chord of the joist. Load resulting from a slope as high as 4:12 has a negligible effect on the chords or webs. The chord size is generally governed by the maximum moment at the center, thus the axial load accumulated toward the low end of the joist does not govern over the chord force at the center of the joist. 15 the span is defined along the slope, the code specified uniform distributed roof Live Load, Lr, and roof Snow Load, S, which are defined on the horizontal projection, must be decreased in the same proportion that the span increases as compared to the horizontal projection of span. This is independent of the joist profile. For a flat span Rs = 1. SP-Series Design 2 Rise Run SPECIAL PROFILE JOISTS, SP-SERIES 2 Special Profile Joists Introduction Slope Ratio, Rs = Ratio of the=horizontal projection of the span to the defined onatthe slope. Whe RsProjection Rise the difference in elevation between theactual top ofspan the joist chord Run , and roof the span is defined along the slope, the code specified uniform distributed roof Live Load, L r of span Snow Load, Profile Projection Ratio for Gable or Scissor Joists, Rpp = Ratio of the pitched length of the joist top chord to the length Run = horizontal projection of span which are defined on the horizontal projection, must be decreased in the same proportion that theroof span increases defined in Section 904.2. Because the length of the dead load supported by the pitched joist chord is longer than the span, the compared to the horizontal projection of span. This is independent of the joist profile. For a flat span Rs = 1. Dead Load, D, must be increased by the ratio of these values. Note that only dead loads in the pitched part of the roof need adjusted Profile Projection Ratio for Gable or Scissor Joists Rpp = the ratio of the pitched length of the joist top chord to the by Rpp. Dead loads defined in the horizontal plane (e.g. ceiling tiles) should not be adjusted. The roof Live Load, Lr, and Snow Load, S, length of span (defined by2 904.2) 2of the joist. Because the length of the dead load supported by the pitched joist chord is which are defined on the horizontal projection are also not affected. span, Rise Run longer than R the straight-line the roof dead D, must be increasedbetween by the ratio of these Theatroof live Rise =load, the difference in elevation the top of the values. joist chord s load, Lr, and snow load,Run S, which are defined on the horizontal projection are not reduced. Run = horizontal projection of span GableGable or Scissor or joists: Scissor joists: Profile Projection Ratio for Gable or Scissor Joists Rpp = the ratio of the pitched length of the joist top chord to th Pitch = Rise per 12” ofthe the length top chordof the dead load supported by the pitched joist chord 2 by 904.2) of the length of spanPitch (defined joist. Because 144 longer than roof=dead load, increased R pp the straight-line span, thePitch the rise per D, 12”must of thebetop chord by the ratio of these values. The roof liv load, Lr, and snow12 load, S, which are defined on the horizontal projection are not reduced. Profile Projection for joists: Arch or Bowstring Joists, Rpr = Ratio of the arc length of the joist top chord to the length of Gable orRatio Scissor span of the joist. Because the length of the dead load supported by the curved joist chord is longer than the straight-line span, the roof Dead Load, D, must be increased by the ratio of these values in the same proportion that the length of the Pitch 2 144 top chord increases as compared to the horizontal of 12” span. roofchord live load, Lr, and snow load, S, which are R Pitch =Rprojection the rise per of The the top pp Ratio for Arch or Bowstring Joists, Profile Projection pr = Ratio of the arched length of the joist top chord to the length of defined on the horizontal projection are not reduced. 12 span defined in Section 904.2. Because the length of the dead load supported by the arched joist chord is longer than the span, the roof Dead Load,orD,Bowstring must be increased by the ratio of these values. Note that only dead loads in the arched part of the roof need Arch joists: Profile Projection Ratio for Arch or Bowstring Joists, Rpr = Ratio of the arc length of the joist top chord to the length adjusted by R . Dead loads defined in the horizontal (e.g. ceiling should not adjusted. Thejoist roof Live Load, pr joist. Because the length r, and Snow span of the of plane the dead load tiles) supported bybethe curved chord is Llonger than the straight-lin Load, S, which are defined on the horizontal projection are also not affected. span, the roof Dead Load, D, must be increased by the ratio of these values in the same proportion that the length of th 2 Radius 1 Span SP-Series Design Sin to the horizontal R prchord increases as compared Radius of = the curve thelive top chord andand span is load, S, which a projection top span. Theofroof load, Lr, snow 180 projection Radius 2are defined onSpan the horizontal not reduced. defined in Section 904.2 Arch or Bowstring Arch orjoists: Bowstring joists: 2 Radius R pr Span 180 Span Sin 1 2 Radius Radius = Curve of the top chord and span is defined 904.2of (Span Radius in feet) Radiusin=Section the curve the&top chord and span is defined in Section 904.2 Slope Projection Ratio, Rs = Ratio of span defined on the slope to the horizontal projection of the span. As code specifies, the roof Live Load, Lr, and roof Snow Load, S, are defined on the horizontal projection. Thus, when the joist span is defined along the slope, these loads must be decreased in the same proportion that the span increases as compared to the horizontal projection. Rs is independent of the joist profile should of be the calculated whenever the joist span is sloped. Forthe a horizontal span, Rdefined Slope Projection Ratio, Rsand = Ratio horizontal projection of the span to actual span on the slope. When s = 1. the span is defined along the slope, the code specified uniform distributed roof Live Load, Lr, and roof Snow Load, S, which are defined on the horizontal projection, must be decreased in the same proportion that the span increases as compared to the horizontal projection of span. This is independent of the joist profile. For a flat span Rs = 1. SP-Series Tables SPECIAL PROFILE JOISTS, SP-SERIES Standard Specification Rs Rise 2 Run 2 Run Rise = Difference in elevation between the top of the joist chord at each bearing location Rise = the difference in elevation between the top of the joist chord at Run = Horizontal projection of span Run = horizontal projection of span 9 Profile Projection Ratio for Gable or Scissor Joists Rpp = the ratio of the pitched length of the joist top chord to the length of span (defined by 904.2) of the joist. Because the length of the dead load supported by the pitched joist chord is longer than the straight-line span, the roof dead load, D, must be increased by the ratio of these values. The roof live load, Lr, and snow load, S, which are defined on the horizontal projection are not reduced. Gable or Scissor joists: 16 Discover the easiest way to specify special profile joists: 2 www.newmill.com/digital-tools Pitch 144 R pp Pitch = the rise per 12” of the top chord SPECIAL PROFILE DESIGN EXAMPLES SP-Series Design SCISSOR JOIST DESIGN EXAMPLE The following example will determine the self-weight of an SP-Series, Scissor joist (SPSC). For the design examples, only the snow load development is illustrated. All load combinations should be fully investigated by the engineer of record. Introduction SCISSOR JOIST DESIGN EXAMPLE SP-SERIES DESIGN EXAMPLES The following example will determine the self-weight of an SP-Series, Scissor joist (SPSC). For the design examples, only the SCISSOR JOIST DESIGN EXAMPLE snow load development is illustrated. All load combinations should be fully investigated by the specifying professional. The following example will determine the self-weight of an SP-Series, Scissor joist (SPSC). For the design examples, only the snow load development is illustrated. All load combinations should be fully investigated by the specifying professional. Special Profile Joists Snow Load: Roof Dead (D) Snow: =Snow: 25 psf Ground FlatLoad Roof = 1.0 C Roof Live Load (L ) = 20 psf e r Sloped Roof Snow: Net Uplift (UL) = 70 plf Flat Roof Snow: Sloped Roof Snow: SP-Series Design Design Criteria: Design Code: IBC-2006 and ASCE 7-05 Project Location: Grand Rapids, MI Joist Span = 60’-0” (Center to Center of Steel supports) Load Combinations: ASD Joist Spacing = 9’-0” Building Class: II Roof Pitch = 3:12 = .25:1 Design Criteria: Importance Factor I = 1.0 Exposure C Design Code: IBC 2006 and ASCE 7-05 DesignProject Criteria: Location: Grand Rapids, Mich. Joist Span = 60’-0” (Center to Center of Steel supports) Loading: Load Combinations: ASD Joist Spacing = 9’-0” Design Code: IBCClass: 2006 IIand ASCE 7-05 Roof Dead Load (D) = 25 psf includes for joist self-weight Building Roofestimate Pitch = 3:12 Project Location: Grand Rapids, Mich. Joistnot Span = 60’-0” Importance Factor 1.0 psf Exposure C (center to center of steel supports) reducible Roof Live Load (Lr) I== 20 Load Combinations: Joistcalculations Spacing = 9’-0” Roof Net UpliftASD (UL) = 70 plf not shown Loading: Building Class: II Roof Pitch = 3:12 Roof Dead Load (D) = 25 psf includes estimate for joist self-weight Importance Factor: I = 1.0 Exposure C Snow Load: not reducible Roof Live Load (Lr) = 20 psf = 35 psf Ground Snow: p Roof Net Uplift (UL) = 70 plf g calculations not shown Ct = 1.0 Cs = 1.0 Ce = 1.0 Loading: for joist self-weight psfCestimate ppgf =includes =35 0.7 = 24.5 psf e Ct I pg Cpt =not 1.0 Cs = = 1.0 reducible =C p 24.5 psf s s f calculations not shown pf = 0.7 Ce Ct I pg ps = Cs pf = 24.5 psf = 24.5 psf Snow Load: The first step in determining joist designation loads is to apply the adjustment ratios, Rs and Rpp to the joist span and geometry. As shown definitions, uniform dead, live and snow loads need adjustment for the actual length and Ground Snow: in thepgratio = 35 psf projected length of span depending on the Cload application. C = 1.0 C = 1.0 e t s = 1.0 The first step is to adjust the dead load by the Profile Projection Ratio, Rpp. Rs 2pf = 0.7 Ce Ct I pg = 24.5 psf FlatRise Roof 2Snow: 2 Run 144 3 2 144 = 24.5 psf R = 1 and no adjustment to the Live Load or Snow Load is required. Pitch f = 0 therefore s R Sloped Roof Snow: ps ==CspRise = 1.031 pp Run12 SP-Series Tables 12 x joistProjection spacing =Ratio, 25 psf uniform Dead Load, D,R isppload 25applies: psf RppProfile Since this is aisScissor joist, TheThe first step to adjust the dead by xthe Rppx. 1.031 x 9’-0” c-c = 232 plf. The uniform roof Live Load, Lr, is 20 psf x joist spacing = 20 psf x 9’-0” c-c = 180 plf. 3 2 144 Pitch 2 144 The spacing = 24.5 psf x 9’-0” c-c = 221 plf. R ppuniform roof Snow Load,=S, = 24.5 psf x joist = 1.031 12 12 The uniform sloped roof Snow Load, S, = 24.5 psf governs, as it exceeds the 20 psf live load. TheThus, uniform Load,uniform D, is 25Total psf x Load, Rpp x joist 25S) psf= x232 1.031 c-c == 453 232 plf. plf x+9’-0” 221 plf plf. theDead resulting TL =spacing D + (L=r or The uniform roof Live Load, Lr, is 20 psf x joist spacing = 20 psf x 9’-0” c-c = 180 plf. Standard Specification The uniform roof Snow Load, S, = 24.5 psf x joist spacing = 24.5 psf x 9’-0” c-c = 221 plf. The uniform sloped roof Snow Load, S, = 24.5 psf governs, as it exceeds the 20 psf live load. Thus, the resulting uniform Total Load, TL = D + (Lr or S) = 232 plf + 221 plf = 453 plf. 13 10 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 17 Introduction SP-Series Design SP-SERIES DESIGN EXAMPLES The next step is to determine the equivalent total uniform load, Weq, that results in a shear or moment equal to the shear or moment forThe the next worst-case loading conditions. For this example, refer to ASCE 7-05 Section 2.4.1 load case 3: D + (L or S). r step is to determine the equivalent total uniform load, W that results in a shear or moment equal to the shear eq, or moment for the worst-case loading conditions. For this example, refer to ASCE 7-05 Section 2.4.1 load case 3: D + (Lr For orthe S).uniform Snow Load case the uniform Total Load, TL = 453 plf. WeqV-TL = WeqM-TL = 453 plf uniform Snow casecheck the uniform Total For the For the Live LoadLoad deflection Weqб-LL = 221Load, plf TL = 453 plf. WeqV-TL = WeqM-TL = 453 plf For the Live Load deflection check Weq-LL = 221 plf For unbalanced Snow Load case per ASCE 7-05 Section 7.6.1: Special Profile Joists For unbalanced 7.6.1: Leeward side: Windward side: Snow Load, per ASCE 7-05 Section Windward side: Uniform Snow Load = 0.3*ps = 7.35 psf Uniform Snow Load = 0.3*ps = 7.35 psf Leeward side: Uniform Snow Load full width leeward = ps = 24.5 psf Plus rectangular Snow Load surcharge = hd x γ/√S Uniform snow load full width leeward = ps = 24.5 psf Where hd = 0.43 x 3√lu x 4√ (pg+10) -1.5 = 1.96 Plus rectangular snow load surcharge = hd x γ /√S γ = 0.13 x pg +14 = 18.55 S = .25 lu = 60 / 2 = 30 Where h = 0.43 x 3√lu x 4√ (pg+10) -1.5 = 1.96 Rectangulard Snow Load surcharge = 1.96 x 18.55 / 0.5 = 72.72 psf γ = 0.13 x pg +14 = 18.55 S = .25 lu = 60 / 2 = 30 Width of surcharge from ridge = (8 / 3) x √S x hd Rectangular snow load surcharge = 1.96 x 18.55 / 0.5 = 72.72 psf Width fromfrom ridge = (8=/(8 3)/x3)0.5 x 1.96 Widthofofsurcharge surcharge ridge x √S x h= 2.613’ d SP-Series Tables SP-Series Design Width of surcharge from ridge = (8 / 3) x 0.5 x 1.96 = 2.613’ The unbalanced snow load case at a span of 60’ results in a maximum shear and moment with equivalent uniform loads: The unbalanced Snow Load case at a span of 60’ results in a maximum shear and moment with equivalent uniform loads: Vub = 12.825 kips Mub = 181.425 kip-ft. WeqV-TL = 2 x Vub / L WeqM-TL = 8 x Mub / L2 = 427 plf = 403 plf Vub = 12.825 kips Weqv-TL = 2 x Vub / L = 427 plf. 2 M = 181.425 kip-ft. W = 8 x M / L 403 plf ub eqm-TL For determining uniform total load to use for theubSP-Series Weight =Table, it is suggested that the designer use the Weq Standard Specification based on the maximum moment, since the chords for a joist comprise most of the joist self-weight. This will give a close approximation to the actual weight and the number of bridging rows for cost comparisons and estimating. Entering the For determining uniform Total Load to use for the SP-Series Weight Table, it is suggested that the designer use the Weq based on tables, the uniform total load of Weq = 453 plf should be used and should be rounded up to 500 plf to select the proper the maximum moment, since the chords for a joist comprise most of the joist self-weight. This will give a close approximation to the joist from the SPSC Weight Table. The specifying professional is reminded to provide specific load diagrams for actual bid actual weight the number rows must for cost estimating. Entering thefor tables, thefinal uniform Total In Load of cases, documents and for NMBS, as of allbridging load cases becomparisons checked forand accurate quoting and actual design. some Wthe 453 plf should be used and should be rounded up to 500 plf to select the proper joist from the SPSC Weight Table. The eq = unbalanced snow load may govern the final web, weld, and top chord end panel design. specifying professional is reminded to provide specific load diagrams for actual contract documents for NMBS, as all load cases must be checked for accurate quoting and for actual final design. In some cases, the unbalanced Snow Load may govern the final web, weld, and top chord end panel design. 18 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 14 SPECIAL PROFILE JOISTS, SP-SERIES SPECIAL PROFILE DESIGN EXAMPLES SP-Series Design Introduction Slope Projection Ratio, thethe horizontal projection the span the actualthat span on use the slope. When s = Ratio For determining uniform total R load to useoffor SP-Series Weight of Table, it is to suggested thedefined designer the Weq and will roofgive Snow Load, S, theonspan defined moment along thesince slope, code for specified roof Live Load, Lr, This based the is maximum thethe chords a joist uniform comprisedistributed most of the joist self-weight. a close which are to defined on the horizontal projection, must be decreased thecomparisons same proportion that the span increases approximation the actual weight and the number of bridging rows for in cost and estimating. Entering the as Since the span of horizontal this joist is horizontal, there isspan. no adjustment needed to account for the sloped span.For a flat span R = 1. compared to the Thisbeisused independent of the profile. should and should bejoist rounded up to 500 plf to select the proper tables, the uniform total load ofprojection Weq = 453ofplf s joist from the (SPSC) Weight Table. The specifying professional is reminded to provide specific load diagrams for actual bid documents for NMBS,2 as all load cases must be checked for accurate quoting and for actual final design. In this 2 Run Risesnow RiseRise = 0the and Rundifference = 12 weld, therefore Rs top = 1.0 example the unbalanced load may govern web, chord end panel design. Rs = final the inand elevation between the top of the joist chord at Run Special Profile Joists The next step is to determine the actual joist Run depth be specified. Generally speaking, for parallel chord profiles such as = to horizontal projection of span Arch or Scissor, the deeper parallel chord depth is the lightest and usually most economical. In this example the top of next step is to determine The the actual joist to be The tabulated joist weight ridge in the weight table is also based on and a joist Profile is The at 130’-0” + 7’-6”=137’-6”. bottom of depth the joist is at R 134’-0¾”. This gives depth of of 3’-5 or 41.25” of theapitched length the¼”joist top chord to the Projection Ratio for Gable or Scissor Joists pp = the ratio specified. In this example, the top of joist is at 130’-0” + 7’limiting the joist live load deflection to L/240 based on a live chord depthofofspan 40”. (defined by 904.2) of the joist. Because the length of the dead load supported by the pitched joist chord is length 6”=137’-6”. The bottom of the joist is at 134’-0¾”. This gives load not to exceed the tabulated total load 500 plf x 0.75 = longer than the straight-line span, the roof dead load, D, must be increased by the ratio of these values. The roof live a ridge depth of 3’-5¼” or 41.25” and a chord depth of 375 plf, which is greater than the 221 plf determined in the To determine the snow estimated in defined plf, estimated number ofprojection bridging rows, minimum seat depth, enter the load, Lr, and load,self-weight S, which are on the horizontal are notand reduced. 40”. Generally speaking, greater depths will yield lighter and design example. Scissor Joist (SPSC) Weight Table at the 60’ span (page 55), 40” parallel chord depth, slope of 3:12 for a total uniform most economical designs. easy way to load ofusually 500 plf provides a estimated self-weight of remember 27 plf. Also note that the joist profile requires 3 rows of bridging and has Gable or Scissor joists:An this is; seat ‘deeper is cheaper.’ The resulting designation is: 40not SPSC 453the / 221 / listed since the table does mark weight a minimum depth of 5”. Also note that for a pin-roller support x ≤ 2”,SP-Series 70: Span = 60’-0”; Top Chord Pitch = 3 on 12. as having x > 2”. Pitch 2self-weight 144 in plf, estimated number To determine the estimated R pp Pitch = the rise per 12” of the top chord of bridging rows, and thein12 minimum seat depth, the based Scissor on limiting The tabulated joist weight the weight table enter is also the joist live loadonly deflection L/240 based This example investigates the basictocalculation for aon a live Joistto(SPSC) Weight Table at the 60’ load span 500 (pageplf62), 40” = 375 load not exceed the tabulated total x 0.75 plf, which is greater than the 221 plf determined snow load example. All loading conditions, combinations, in the design example. parallel chord depth, slope of 3:12 for a total uniform load of witharc local building requirements should Ratio of the length of code the joist top chord to the length of Profile Projection Ratio for Arch or Bowstring Joists, Rand pr =compliance 500of plf the and find theBecause estimated self-weight of 27 noteload that supported be fully investigated by thejoist specifying professional. Specific span joist. the length of plf. theAlso dead by the curved chord is longer than the straight-line The span, resulting designation is:of40 SPSC 453 has /by 221 Span = 60’-0”; TopinChord Pitch =furnished 3 on 12.that the joist profile requires threeD,rows bridging and a / 70; loads load combinations shall be to NMBS theSP-Series roof Dead Load, must be increased the ratio ofand these values the same proportion the length of the minimum seat depth of 5”. Also note that for a pin-roller support, by the specifying in the form of the uniform loadS, which are top chord increases as compared to the horizontal projection of span. Theprofessional roof live load, Lr, and snow load, This defined example only basic load example. All loading combinations and the horizontal atprojection thethe roller end ofnot thereduced. joist isfor lessa snow designation and/or load diagramsconditions, for accurate quoting and oninvestigates the deflection horizontal arecalculation compliance requirements should by the specifying professional. Specific loads and than 2 with incheslocal sincebuilding the tablecode does not mark the weight listedbe reviewed for actual final design. load combinations be furnished as having бx >orshall 2”. Arch Bowstring joists: to NMBS by the specifying professional in the form of the uniform load designation and/or load diagrams for accurate quoting and for actual final design. Span Sin 1 2 Radius SP-Series Design 2 Radius R pr Span 180 Radius = the curve of the top chord and span is defined in Section 904.2 SP-Series Tables Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 19 Standard Specification 12 9 Introduction SP-Series Design SP-SERIES DESIGN EXAMPLES BOWSTRING JOIST DESIGN EXAMPLE JOIST DESIGN EXAMPLE TheBOWSTRING following example will determine the self-weight of an SP-Series, Bowstring joist (SPBW). For the design examples, only The following example determineAll the self-weight of anshould SP-Series, Bowstring joistby (SPBW). For the design examples, the snow load developmentwill is illustrated. load combinations be fully investigated the specifying professional. SP-Series Design Special Profile Joists only the snow load development is illustrated. All load combinations should be fully investigated by the specifying professional. Design Criteria: Design Code: IBC 2006 ASCE 7-05 Clear Span = 50’-0” SP-Series Tables DesignProject Criteria: Location: Grand Rapids, Mich. Joist Span = 53’-9” on Slope DesignLoad Code:combinations: IBC 2006 and ASCE 7-05 Span = 50’-0” ASD Joist Spacing Clear = 6’-0” Project Building Location:Class: GrandIIRapids, Mich. Joist Span = 53’-9” on Slope Exposure C Importance Factor I = 1.0 Load combinations: ASD Joist Spacing = 6’-0” Building Class: IIExposure C Loading:Factor I = 1.0 Importance Roof Dead Load (D) = 20 psf Includes estimate for joist self-weight = 20 psf Not reducible Roof Live Load (Lr) Loading: Net Uplift (UL) = 70 plf Calculations not shownestimate for joist self-weight Roof Dead Load (D) = 20 psf Includes Roof Live LoadLoad (Lr)= 20 psfNot reducible Snow Roof Net Uplift (UL)snow plf Calculations not shown 35 psf Ground pg== 70 C = 1.0 C = 1.0 t Snow Load e Ground Snowp = 35 Ce psf Ct I pg Flat roof snow pf =g0.7 CSloped = 1.0 C = 1.0 Roof Snow: ps =t Cs pf e Flat Roof Snow Sloped Roof Snow pf = 0.7 Ce Ct I pg ps = Cs pf Standard Specification Cs = 1.0 = 24.5 psf = 24.5Cpsf s = 1.0 = 24.5 psf = 24.5 psf 16 20 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools SPECIAL PROFILE DESIGN EXAMPLES SP-Series Design Rise 2 Run 2 Rise = 4 and Run = 12 therefore Rs = 1.0541 The first step is to adjust Runthe dead load, D, by the Profile Projection Ratio, Rpr. Introduction Rs Since this is a Bowstring joist, Rpr applies: 2 Radius R pr Span 180 Span 2 42 1 53.75 Sin 1 1.085 Sin 2 42 2 Radius 53.75 180 The adjusted uniform Dead Load is D x Rpr x joist spacing = 20 psf x 1.085 x 6’-0” c-c = 131 plf. Special Profile Joists The uniform roof Live Load is Lr / Rs x joist spacing = 20 psf / 1.054 x 6’-0” c-c = 114 plf. The adjusted Dead Load is D x Rpr x joist spacing = 20 psf x 1.085 x 6’-0” c-c = 131 plf. The roof is S / R x joist spacing = 24.5 psf / 1.054 x 6’-0” c-c = 140 plf. The uniform uniform roof LiveSnow Load LLoad r x joist spacing s= 20 psf x 6’-0” c-c = 120 plf. The sloped Load, S, == 24.5 psfxgoverns, it exceeds the 20 psf live load. The uniform uniform roof Snow roof LoadSnow is S x joist spacing 24.5 psf 6’-0” c-c =as 147 plf. The resulting uniform sloped roof Snow S, =TL 24.5 exceeds 20 plf psf =live load. plf +the 140 271 plf. The uniform TotalLoad, Load, = Dpsf+ governs, (Lr or S)as=it 131 SP-Series Design The next resulting uniform Load, TL the = D equivalent + (Lr or S) = 131 plf + 147 plf. that will result in a moment and shear for the worse The step is toTotal determine uniform loadplfon= 278 the joist case loading conditions. For this ASD example, check Section 2.4.1 load case 3 D + (Lr or S) For uniform loads, there is no further calculation required. The worse case from the above is the governing uniform case and to equivalent the equivalent uniform load the unbalanced caseequal (e.g.tosnow); when applicable. The should next stepbe is tocompared determine the total uniform load, Weqfor , that results in a shear load or moment the shear or moment for the worst-case loading conditions. For this example, refer to ASCE 7-05 Section 2.4.1 load case 3: D + (Lr or S). Maximum uniform, Total Load, TL = 271 plf. Since loadSnow is uniform there no calculation Hence, For thethe uniform Load case the is uniform Total Load, required. TL = 278 plf. Total Uniform Load TL = Weqv = Weqm = 271 plf. WeqV-TL = WeqM-TL = 278 plf. For checking the Live Load deflection, For Live Load deflection check WeqM-LL = 147 plf. WeqLL = 140 plf. SP-Series Tables For unbalanced the unbalancedsnow Snowload Loadper caseASCE-7 per ASCE 7-05 Section For section 7.6.2: 7.6.2. With the Bowstring sloped the crown shifts towards the high end per the attached diagram to 36’-5 3/8” from the inside Withofthewall. Bowstring sloped, thethe crown shifts towards the high end 36’-5 3/8”byfrom the inside facebeam of wall.with For simplicity, the unbalanced face For simplicity, equivalent uniform load is to calculated using a simple the leeward equivalent uniform load is calculated by using a simple beam with the leeward unbalanced snow at the inside face of the wall and snow at the inside face of the wall and not at the eave. This is slightly conservative and has a small effect on the design. not at the eave or end of the extension. This is slightly conservative and has a negligible effect on the resulting maximum moment. Windward Side: Leeward Side: No snow load per Figure 7.3 Case 1 Snow Load S = 2 x pf x Cs / Ce = 49 psf Windward Side: Leeward With the slope at the eave < 30 degrees Snow LoadSide: x Spacing = 49 psf x 6’-0” = 294 plf No Snow Load per Figure 7.3 Case 1 Snow Load S = 2 x pf x Cs / Ce = 49 psf at the eave With the slope at the eave < 30 degrees Load S = S x Spacing = 49 psf x 6’-0” = 294 plf AtSnow the Crown: Snow Load S = 0.5 x pf = 12.25 psf 12.25 psf crown SnowLoad LoadxS Spacing = 0.5 x pf== 12.25 Snow psfatx the 6’-0” = 73.5 plf Snow Load S = S x Spacing = 12.25 psf x 6’-0” = 74 plf Standard Specification 14 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 21 Introduction SP-Series Design Special Profile Joists SP-SERIES DESIGN EXAMPLES SP-Series Design The unbalanced snow load case at a span of 51’ results in a maximum shear and moment and equivalent uniform loads: Vub = 8.128 kips WeqV-TL = 2 x Vub / L = 319 plf. The unbalanced Snowkip-ft. Load case at aWspan of 51’ results in2 a maximum = 267 plf. shear and moment and equivalent uniform loads: Mub = 86.78 eqM-TL = 8 x Mub / L Vub = 8.128 kips WeqV-TL = 2 x Vub / L = 319 plf. The next step is to adjust the maximum Weq for TL2 to the sloped span to utilize the SP-Series Table. Since this is a M = 86.78 kip-ft. W = 8 x M / L = plf. ub eqM-TL the loads ub normal to 267 Bowstring joist with sloped bearings, the span must be determined. It is suggested that the designer use the Weq based on the maximum moment, since the chords for a joist comprise most of the joist self-weight. This will give a close approximation to the actual weight and the number of bridging rows for cost comparisons and estimating. TheProjection next step is toRatio, adjust the forhorizontal TL to the sloped span to utilize SP-Series Weight Table. Since this is aonBowstring Slope Rsmaximum = Ratio W ofeq the projection of thethe span to the actual span defined the slope. When joist with bearings, the loads normal to the span must be determined. It is suggested that the designer use the W based Load, S, , and roof Snow the span is sloped defined along the slope, the code specified uniform distributed roof Live Load, L eq r 2 2 SPECIAL PROFILE JOISTS, SP-SERIES Risethesince Runthe chords which defined on horizontal projection, must decreased in the same thatapproximation the span increases as on are the maximum for joistRun comprise most of the joist self-weight. Thisproportion will give a close to Rs moment, Rise = 4aand = 12be therefore Rs = 1.054 Runnumber compared to weight the horizontal projection of span. is comparisons independent ofestimating. the joist profile. For a flat span Rs = 1. the actual and the of bridging rows This for cost and SP-Series Tables Adjusted Weq = Weq/ Rs = 278 plf / 1.054 = 264 plf at the sloped span = 53’-9” Rise 2 Run 2 4 /and Run = 12plftherefore Rs = 1.054between the top of the joist chord at 147=Rise plf 1.054 = 140 Rs Adjusted WeqLL = WeqLL / Rs =Rise = the difference in elevation Run plf and rounding up to 300 plf to select the proper joist from the Entering the tables with the uniform total load of Weq = 264projection Run = horizontal of span SPBW Weight Table. The specifying professional is reminded to provide specific load diagrams in the contract documents Adjusted Weq = In Wsome = 278the plf unbalanced / 1.054 = 264 at the = 53’-9” for NMBS. snowplf load maysloped governspan the final web, weld, and top chord end panel design. eq/ Rscases, Profile Projection Ratio for Gable or Scissor Joists Rpp = the ratio of the pitched length of the joist top chord to the length of The span (defined by/ 904.2) joist. Because length deadasload supported pitchedselfjoist chord is actual depth 136” = and theplftop the chord radiusofis the specified 42’ To determineby thethe estimated Adjusted W =joist WeqLL Rsis=specified 147ofplfthe /as1.054 140 eqLL weight plf, estimated span, numberthe of bridging rows load, and theD, minimum seatincreased depth at the span,ofinterpolation needsThe to roof live longer than theinstraight-line roof dead must be by53.75 the ftratio these values. be utilized, since the table only has information for 50 ft (page 41) and 61 ft (page 42) spans. The closest joist that fits the load,Entering Lr, and S, which on264 theplf horizontal are not reduced. thesnow tables,load, the uniform Total are Loaddefined of Weq = should be projection used and should be rounded up to 300 plf to select the example joist profile for the 50 ft span weighs 27 plf at Center Depth = 136 in, Top Chord Radius = 42 ft and TL = 300 plf Standard Specification joist that fits the example joistspecifying profile forprofessional the 60 ft span weighs 33 at Center Depth 148 in, Top properThe joistclosest from the SPBW Weight Table. The is reminded to plf provide specific load= diagrams forChord actual Gable or Scissor joists: Radius = 50 ft for andNMBS, TL = 300 contract documents as plf. all load cases must be checked for accurate quoting and for actual final design. In some cases, the unbalanced Snow Load may govern the final web, weld, and top chord end panel design. Pitch 2 144 R pp joist depth is specified as 136” and Pitch = the rise per is12” of theas top chord The actual the top chord radius specified 42’. To determine the estimated self-weight in plf, 12 estimated number of bridging rows and the minimum seat depth at the 53.75 ft span, interpolation needs to be utilized, since the 18 Profile Projection Ratio for Arch or Bowstring Joists, Rpr = Ratio of the arc length of the joist top chord to the length of span of the joist. Because the length of the dead load supported by the curved joist chord is longer than the straight-line span, the roof Dead Load, D, must be increased by the ratio of these values in the same proportion that the length of the top chord increases as compared to the horizontal projection of span. The roof live load, Lr, and snow load, S, which are defined on the horizontal projection are not reduced. 22 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Arch or Bowstring joists: SP-Series Design Introduction table only has information for 50 ft (page45) and 60 ft (page 46) spans. The closest joist that fits the example joist profile for the 50 ft span weighs 27 plf at Center Depth = 136 in, Top Chord Radius = 42 ft and TL = 300 plf. The closest joist that fits the example joist profile for the 60 ft span weighs 33 plf at Center Depth = 148 in, Top Chord Radius = 50 ft and TL = 300 plf. This selection is chosen, since the resulting self-weight is slightly more conservative compared to choosing the joist at Center Depth = 132 in, Top Chord Radius = 50 ft and TL = 300 plf. Using linear interpolation, the self-weight of the example joist is: (53.75 ft. – 50 ft.) (60 ft. – 50 ft.) x (33 plf – 27 plf) = 29 plf + 27 plf ~ Special Profile Joists In addition, both selections for the 50 ft span and the 60 ft span show that a 5” minimum seat depth and four rows of X-bolted bridging are required. The same will hold true for the example joist profile. The table gives the minimum seat depth of 5” based on a flat span, which would require adjustment for slope and top chord extensions. The tabulated joist weight in the Weight Table is also based on limiting the joist live load deflection to L/240 based on a live load not to exceed the tabulated total load 300 plf x 0.75 = 225 plf, which is greater than the 140 plf determined in the design example. The resulting SP-Series designation is: 136 SPBW 264 / 140 / 70; Span = 53’-9”; Top Chord Radius = 42’. SP-Series Design This example investigates only the basic calculation for a snow load example. All loading conditions, combinations, and compliance with local building code requirements should be fully investigated by the specifying professional. Specific loads and load combinations shall be furnished to NMBS by the specifying professional in the form of the uniform load designation and/or load diagrams for accurate quoting and for final design. SP-Series Tables Standard Specification Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 23 Introduction Gable Joist (SPGB) Tables The following weight tables are representative of SP-Series linear foot. This catalog provides two design examples for joist designs for Gable Joists with parameters shown in the reference and clarification on design issues. The following GABLE JOIST diagram below. The maximum allowable Live Load deflection tables are not (SPGB) representative WEIGHT of any limits orTABLES constraints is L/240 for a Live Load equal to 75 percent of the Total Load on design or constructability by NMBS. For further information, The following weight tables are representative of SP-Series joist designs for Gable Joists with parameters shown in the below. The maximum allowable for the joist is L/240 for ayour Live nearest Load equal to 75representative percent of theorTotal listeddiagram in the table. The tables also give bridgingdeflection requirements please contact NMBS visit listed in the table. The tables give requirements per Section 904.5(d), the required seat depth for the per Load Section 904.5(d), the required seatalso depth forbridging the given www.newmill.com. given profile, as well as the estimated pounds per linear foot. This catalog provides two complete design examples for profile, as well as the estimated self-weight in pounds per reference and clarification on design issues. The following tables are not representative of any limits or constraints on design or constructability per NMBS. For further information, please contact your nearest NMBS representative or visit www.newmill.com. ALL TABLES ARE BASED ON ASD SP-Series Design Special Profile Joists ALL TABLES ARE BASED ON ASD Standard Specification SP-Series Tables GABLE JOIST (SPGB) 20 24 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Gable Joist (SPGB) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 8 8 8 8 8 7 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 8 8 8 8 8 9 9 9 9 9 8 8 9 9 9 9 9 9 9 10 10 10 9 9 10 11 11 11 11 11 11 13 13 13 12 12 12 8 8 8 8 8 7 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 8 8 8 8 9 9 9 9 9 8 8 9 9 9 9 9 9 9 10 10 10 10 10 10 11 11 11 11 11 11 13 13 13 12 12 12 8 8 8 8 8 7 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 8 8 8 8 9 9 9 9 9 8 8 9 9 9 9 9 9 9 10 10 10 10 10 10 11 11 11 11 11 11 13 13 13 13 12 12 Joist Self-Weight - Pounds per Linear Foot (plf) 8 8 8 8 8 7 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 8 8 8 8 8 9 8 8 8 8 8 9 9 9 9 9 9 9 10 10 10 10 10 10 12 12 12 11 11 11 8 8 8 8 8 7 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 8 8 8 8 8 9 8 8 8 8 8 9 9 9 9 9 9 9 10 10 10 10 10 10 12 12 12 11 11 11 8 8 8 8 8 7 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 8 8 8 8 8 9 8 8 8 8 8 9 9 9 9 9 9 9 10 10 10 10 10 10 12 12 12 11 11 11 8 8 8 8 8 7 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 8 8 8 8 8 9 9 8 8 8 8 8 9 8 8 8 8 8 9 9 9 9 9 9 9 10 10 10 10 10 10 12 12 12 11 11 11 8 8 8 8 8 7 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 8 8 8 8 8 9 9 8 8 8 8 8 9 8 8 8 8 8 9 9 9 9 9 9 9 10 10 10 10 10 10 12 12 12 12 11 11 8 8 8 8 8 7 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 8 8 8 8 8 9 9 8 8 8 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 11 10 10 10 10 10 13 12 12 12 11 11 8 8 8 8 8 7 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 8 8 8 8 8 9 9 8 8 9 8 8 9 9 9 9 9 9 9 9 9 9 9 9 10 11 10 10 10 11 10 13 12 12 12 12 11 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 8 8 8 8 8 7 8 8 8 8 8 8 8 8 8 8 8 8 7 7 7 8 8 8 8 8 8 8 9 9 8 8 8 8 8 9 8 8 8 8 8 9 9 9 9 9 9 9 10 10 10 10 10 10 12 12 12 11 11 11 SP-Series Design Top Chord Pitch in/ft 0.375 0.500 0.625 0.750 0.875 1.000 0.875 1.000 1.250 1.500 2.000 3.000 1.000 1.250 1.500 2.000 3.000 4.000 1.000 1.250 1.500 2.000 3.000 4.000 1.250 1.500 2.000 3.000 4.000 6.000 1.250 1.500 2.000 3.000 4.000 6.000 1.250 1.500 2.000 3.000 4.000 6.000 1.250 1.500 2.000 3.000 4.000 6.000 1.250 1.500 2.000 3.000 4.000 6.000 1.250 1.500 2.000 3.000 4.000 6.000 Special Profile Joists Center Depth in 20 20 20 20 20 20 24 24 24 24 24 24 28 28 28 28 28 28 32 32 32 32 32 32 38 38 38 38 38 38 44 44 44 44 44 44 50 50 50 50 50 50 58 58 58 58 58 58 66 66 66 66 66 66 76 76 76 76 76 76 Introduction Span ft 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 End Depth in 18.1 17.5 16.9 16.3 15.6 15.0 19.6 19.0 17.8 16.5 14.0 9.0 23.0 21.8 20.5 18.0 13.0 8.0 27.0 25.8 24.5 22.0 17.0 12.0 31.8 30.5 28.0 23.0 18.0 8.0 37.8 36.5 34.0 29.0 24.0 14.0 43.8 42.5 40.0 35.0 30.0 20.0 51.8 50.5 48.0 43.0 38.0 28.0 59.8 58.5 56.0 51.0 46.0 36.0 69.8 68.5 66.0 61.0 56.0 46.0 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 25 Introduction Gable Joist (SPGB) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 End Depth in 17.5 16.3 15.0 13.8 12.5 11.3 17.8 16.5 15.3 14.0 11.5 9.0 22.5 21.3 20.0 17.5 15.0 10.0 27.3 26.0 23.5 21.0 16.0 6.0 33.3 32.0 29.5 27.0 22.0 12.0 40.0 37.5 35.0 30.0 20.0 10.0 48.0 45.5 43.0 38.0 28.0 18.0 55.5 53.0 48.0 38.0 28.0 8.0 65.5 63.0 58.0 48.0 38.0 18.0 77.5 75.0 70.0 60.0 50.0 30.0 Center Depth in 20 20 20 20 20 20 24 24 24 24 24 24 30 30 30 30 30 30 36 36 36 36 36 36 42 42 42 42 42 42 50 50 50 50 50 50 58 58 58 58 58 58 68 68 68 68 68 68 78 78 78 78 78 78 90 90 90 90 90 90 Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.875 1.000 1.250 1.500 2.000 3.000 0.875 1.000 1.250 1.500 2.000 3.000 1.000 1.250 1.500 2.000 3.000 4.000 1.000 1.250 1.500 2.000 3.000 4.000 1.250 1.500 2.000 3.000 4.000 6.000 1.250 1.500 2.000 3.000 4.000 6.000 1.250 1.500 2.000 3.000 4.000 6.000 Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 8 8 7 8 8 8 8 8 7 9 9 9 8 8 8 9 9 9 9 9 8 11 11 11 10 10 10 16 15 14 12 11 11 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 8 8 8 8 8 7 8 8 8 8 8 8 9 9 9 8 9 8 10 10 9 9 9 9 12 12 11 10 10 10 16 16 14 13 11 11 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 8 8 8 8 8 8 8 7 8 8 8 8 8 8 9 9 9 8 9 8 10 10 10 9 9 9 12 12 12 11 10 10 17 17 16 13 12 11 7 7 7 7 7 7 7 7 7 7 7 7 8 8 7 7 7 7 7 7 8 8 8 8 8 8 8 8 8 7 8 8 8 8 8 8 10 10 9 9 9 9 11 11 10 9 9 9 13 13 12 11 10 11 19 19 17 13 12 11 7 7 7 7 7 7 7 7 7 7 7 7 8 8 8 7 7 7 8 8 8 8 8 8 8 8 8 8 8 8 9 9 8 8 9 8 10 10 10 9 9 9 11 11 10 10 9 9 13 13 12 11 11 11 19 19 18 14 12 11 8 8 8 8 8 8 8 8 8 7 8 8 8 8 8 8 8 7 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 8 9 8 10 10 10 10 9 9 11 11 11 10 9 9 14 14 13 12 11 11 20 19 18 15 13 12 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 8 8 9 9 9 9 9 8 10 10 10 10 9 9 12 12 11 10 9 9 15 15 14 12 11 11 20 19 18 15 13 12 8 9 9 9 9 9 8 9 9 8 9 9 9 9 8 8 8 8 9 9 9 9 9 9 9 9 9 9 9 8 10 10 9 9 9 8 11 11 10 10 9 9 14 12 12 11 9 10 15 15 15 13 11 11 20 20 19 16 14 12 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 26 700 750 800 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 9 10 9 11 11 11 11 9 10 14 13 12 11 10 10 17 16 16 14 11 11 20 20 19 17 15 13 10 10 10 10 10 10 10 10 9 9 10 10 9 10 10 10 9 9 10 10 10 10 10 10 10 10 10 10 10 9 10 10 10 10 10 10 12 12 11 11 10 10 15 14 13 11 11 11 17 17 16 15 12 12 21 20 20 17 15 13 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 9 10 10 10 10 10 10 10 10 10 10 10 10 11 11 11 11 10 10 13 12 12 12 11 11 15 15 14 12 11 11 17 17 17 15 13 12 21 20 20 18 16 13 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Gable Joist (SPGB) Tables Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 16 17 17 18 19 20 14 14 14 14 15 16 13 13 13 13 13 14 13 13 13 13 13 12 14 13 13 13 13 13 13 13 13 13 13 12 16 16 14 13 13 13 18 18 18 16 15 15 21 20 20 19 16 16 24 23 22 20 19 16 18 18 18 20 20 21 15 15 15 15 16 17 13 13 14 13 14 14 13 13 13 13 13 13 14 14 14 14 14 13 14 14 14 15 14 13 18 16 14 14 14 14 19 18 18 17 16 15 21 21 21 19 17 17 25 23 23 20 19 17 20 20 20 20 20 21 16 16 16 16 17 18 14 14 14 14 14 15 14 13 13 13 13 14 14 14 14 14 14 14 15 14 15 15 14 14 18 18 15 15 15 14 20 19 19 17 16 15 22 22 21 19 18 17 25 25 23 21 19 18 Joist Self-Weight - Pounds per Linear Foot (plf) 9 9 9 9 10 10 8 8 8 8 8 9 7 8 8 7 7 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 9 8 8 11 10 10 9 9 8 13 13 12 11 10 9 17 15 14 13 12 11 20 19 17 15 15 12 10 10 11 11 11 12 8 9 9 9 9 10 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 9 8 8 10 9 9 9 8 8 11 11 10 9 9 9 14 13 12 12 11 10 17 16 15 13 12 11 21 20 19 15 15 12 11 12 12 12 13 13 10 10 10 10 10 10 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 10 9 9 11 11 11 10 10 10 15 14 13 12 11 10 18 17 16 14 13 12 21 20 19 16 15 13 13 13 13 13 14 14 10 10 10 10 11 12 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 11 11 11 11 10 10 13 12 11 11 10 10 15 15 14 13 12 11 18 19 17 15 13 13 21 21 19 17 15 13 14 14 14 15 15 16 11 11 11 11 12 13 10 10 10 11 11 10 10 11 11 11 11 10 11 11 11 11 11 10 12 12 11 11 11 10 13 13 12 12 11 11 16 16 15 14 13 12 19 19 18 17 13 14 22 22 20 18 15 14 15 15 16 16 16 17 12 12 12 13 13 14 11 11 11 11 11 11 11 11 11 11 11 11 12 12 12 11 11 11 12 12 12 12 11 11 14 13 13 13 12 12 18 17 16 15 14 13 20 20 19 17 14 14 24 23 21 19 17 14 16 16 16 17 18 17 13 13 13 13 14 15 12 12 12 12 12 12 12 12 12 12 12 12 13 13 12 12 12 12 13 12 13 12 12 12 16 15 13 13 12 12 18 17 16 16 15 14 21 20 19 18 15 15 24 23 22 20 18 16 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 8 8 8 8 9 9 7 7 7 7 7 8 7 7 7 7 7 7 7 7 7 8 7 7 8 8 8 8 8 7 9 9 9 8 8 8 10 10 9 9 9 8 12 12 12 11 10 9 15 14 14 12 11 11 19 18 16 14 14 11 SP-Series Design Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.500 0.625 0.750 0.875 1.000 1.250 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.875 1.000 1.250 1.500 2.000 3.000 1.000 1.250 1.500 2.000 3.000 4.000 1.000 1.250 1.500 2.000 3.000 4.000 1.000 1.250 1.500 2.000 3.000 4.000 1.250 1.500 2.000 3.000 4.000 6.000 Special Profile Joists Center Depth in 20 20 20 20 20 20 26 26 26 26 26 26 32 32 32 32 32 32 40 40 40 40 40 40 48 48 48 48 48 48 58 58 58 58 58 58 68 68 68 68 68 68 80 80 80 80 80 80 92 92 92 92 92 92 106 106 106 106 106 106 Introduction Span ft 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 End Depth in 16.3 14.4 12.5 10.6 8.8 6.9 18.5 16.6 14.8 12.9 11.0 7.3 22.6 20.8 18.9 17.0 13.3 9.5 28.8 26.9 25.0 21.3 17.5 10.0 36.8 34.9 33.0 29.3 25.5 18.0 44.9 43.0 39.3 35.5 28.0 13.0 53.0 49.3 45.5 38.0 23.0 8.0 65.0 61.3 57.5 50.0 35.0 20.0 77.0 73.3 69.5 62.0 47.0 32.0 87.3 83.5 76.0 61.0 46.0 16.0 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 27 Introduction Gable Joist (SPGB) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 End Depth in 19.0 16.5 14.0 11.5 9.0 6.5 20.0 17.5 15.0 12.5 10.0 5.0 25.5 23.0 20.5 18.0 13.0 8.0 31.0 28.5 26.0 21.0 16.0 6.0 41.0 38.5 36.0 31.0 26.0 16.0 48.5 46.0 41.0 36.0 26.0 6.0 60.5 58.0 53.0 48.0 38.0 18.0 70.0 65.0 60.0 50.0 30.0 10.0 84.0 79.0 74.0 64.0 44.0 24.0 100.0 95.0 90.0 80.0 60.0 40.0 Center Depth in 24 24 24 24 24 24 30 30 30 30 30 30 38 38 38 38 38 38 46 46 46 46 46 46 56 56 56 56 56 56 66 66 66 66 66 66 78 78 78 78 78 78 90 90 90 90 90 90 104 104 104 104 104 104 120 120 120 120 120 120 Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.500 0.625 0.750 0.875 1.000 1.250 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.875 1.000 1.250 1.500 2.000 3.000 0.875 1.000 1.250 1.500 2.000 3.000 1.000 1.250 1.500 2.000 3.000 4.000 1.000 1.250 1.500 2.000 3.000 4.000 1.000 1.250 1.500 2.000 3.000 4.000 Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 11 11 12 12 13 13 9 10 10 10 10 12 9 9 9 9 9 9 8 8 8 9 9 8 9 9 9 9 9 8 10 10 10 9 9 9 12 12 11 11 10 9 15 14 13 12 10 10 18 17 17 15 13 12 25 24 22 20 17 16 13 13 14 14 15 16 11 11 11 11 12 13 10 10 10 10 10 10 10 10 9 10 9 10 11 10 10 10 9 9 11 11 11 11 10 10 13 12 11 12 12 10 16 15 14 12 12 11 20 18 18 16 13 13 25 25 23 21 18 16 14 14 15 16 16 17 12 13 13 13 13 16 11 11 11 11 11 12 10 11 10 10 10 10 12 11 11 11 11 10 12 12 12 12 11 11 14 14 13 13 13 12 17 16 15 13 12 12 21 19 20 17 14 13 26 25 23 21 19 17 16 16 16 17 17 20 13 14 14 15 15 17 12 12 12 12 12 13 12 12 12 11 12 12 12 12 12 12 12 11 13 13 13 13 12 11 15 14 14 14 13 13 19 17 15 14 14 13 21 20 20 18 14 15 27 27 24 22 20 18 17 18 18 19 20 21 15 15 16 16 17 19 13 13 13 14 14 15 13 13 13 13 12 14 13 13 13 13 13 13 14 14 14 14 14 12 16 15 14 15 14 13 20 18 16 15 14 14 23 21 20 20 15 15 28 27 25 23 21 18 20 19 20 20 21 24 17 17 16 18 18 20 14 14 14 14 15 16 14 14 13 14 14 14 14 14 14 14 14 14 15 15 15 15 14 13 17 17 16 16 16 14 20 19 17 15 15 16 24 22 22 20 17 17 29 27 26 24 22 21 21 21 21 22 25 25 18 18 18 18 20 22 15 15 15 15 16 17 14 14 14 14 14 15 15 15 14 14 14 15 15 15 15 15 15 14 18 18 16 16 16 15 21 20 19 16 16 16 25 23 23 21 17 18 29 28 26 25 23 21 23 23 25 25 25 28 18 19 20 20 20 26 16 16 16 17 17 19 15 15 15 15 16 17 15 15 15 15 15 15 16 15 16 16 16 15 19 18 18 17 16 16 22 21 19 18 17 17 25 24 23 22 19 18 30 29 27 26 23 21 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 28 700 750 800 25 25 25 28 28 29 20 20 21 21 22 26 17 17 17 17 18 20 16 16 16 16 16 18 16 16 16 15 16 16 16 17 16 16 16 16 19 19 18 17 17 16 23 21 20 18 17 18 25 24 24 22 20 19 32 30 28 26 25 23 26 27 28 28 29 31 21 22 22 23 25 28 19 19 19 19 19 20 17 17 17 17 18 19 16 17 17 17 17 17 17 17 17 17 17 17 20 19 19 18 18 17 23 22 20 19 18 18 26 25 24 23 20 19 33 30 30 26 25 23 28 27 29 29 31 34 22 23 24 25 26 29 19 19 19 19 20 22 18 18 18 18 18 21 18 18 18 17 18 17 18 18 18 17 17 18 21 20 20 19 18 17 25 23 21 19 18 19 28 25 26 24 21 21 33 32 30 27 25 24 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Gable Joist (SPGB) Tables Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 32 32 33 36 38 42 26 26 26 28 28 29 23 22 22 24 26 28 21 21 21 20 21 21 20 19 19 19 19 20 21 21 21 21 20 19 24 23 22 21 21 19 26 26 26 24 22 20 32 31 30 27 24 23 37 36 35 33 28 25 33 36 36 37 40 51 28 28 28 29 29 31 24 24 25 26 26 30 21 21 22 21 22 23 20 20 20 19 20 21 22 21 21 21 20 20 24 24 23 23 22 21 27 27 27 26 23 21 35 33 31 28 26 24 39 36 35 35 29 27 36 38 37 39 41 51 29 29 30 31 31 32 26 26 26 26 28 31 23 23 23 23 23 23 21 21 22 21 21 22 22 22 22 22 21 20 27 25 23 23 23 22 29 27 27 26 23 22 35 35 33 29 27 25 41 38 36 36 31 28 Joist Self-Weight - Pounds per Linear Foot (plf) 16 17 17 18 19 21 13 14 14 14 15 16 12 12 12 12 13 15 12 12 12 12 12 11 12 13 13 12 12 11 13 13 13 13 13 13 15 16 15 14 14 13 21 19 19 17 15 14 28 25 24 20 18 17 31 29 28 27 22 20 18 20 20 20 21 24 16 16 16 16 17 18 14 14 14 14 15 17 13 13 13 13 13 13 14 13 13 14 13 13 15 14 14 15 14 14 16 17 16 16 15 14 22 20 20 18 17 15 28 25 24 22 18 18 32 29 29 27 23 21 21 21 22 23 25 28 17 17 18 18 18 19 15 15 15 15 16 18 15 15 14 14 14 14 16 15 15 15 14 14 15 16 16 16 15 16 18 19 17 17 16 15 22 22 21 19 18 16 28 26 25 23 20 19 33 30 29 29 24 22 24 25 25 25 28 29 19 19 19 20 20 21 17 17 17 17 18 20 16 16 16 16 16 16 16 16 16 16 15 16 17 16 16 17 16 17 20 19 18 17 16 17 23 22 22 21 20 20 29 29 27 24 22 21 34 31 30 30 27 23 25 26 28 28 29 32 20 20 21 21 21 23 19 19 19 19 20 22 18 17 17 17 17 18 17 16 17 16 16 16 17 17 17 17 17 17 20 19 20 19 18 18 24 22 22 21 20 20 29 29 28 24 22 21 36 32 31 31 27 25 28 29 29 29 32 37 22 22 22 23 25 25 19 19 19 20 21 25 18 18 18 18 18 18 18 18 18 18 18 18 19 18 18 18 18 18 21 20 20 19 19 18 24 24 23 21 22 20 31 29 28 24 23 22 37 34 31 31 27 25 29 31 30 32 36 38 25 25 25 26 26 28 21 21 21 22 23 26 20 20 19 19 20 20 18 19 19 18 19 19 20 21 21 20 19 19 23 22 22 21 20 19 26 26 25 22 22 20 32 30 29 26 23 22 37 35 33 31 27 25 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 14 15 15 15 16 17 12 12 12 13 13 13 11 11 11 11 11 14 11 11 11 11 11 11 12 12 11 11 11 11 13 12 12 12 12 12 15 15 14 14 13 12 19 18 17 16 15 13 27 24 22 20 17 16 30 27 27 27 21 20 SP-Series Design Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.375 0.500 0.625 0.750 0.875 1.000 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.875 1.000 1.250 1.500 2.000 3.000 0.875 1.000 1.250 1.500 2.000 3.000 1.000 1.250 1.500 2.000 3.000 4.000 1.000 1.250 1.500 2.000 3.000 4.000 Special Profile Joists Center Depth in 28 28 28 28 28 28 36 36 36 36 36 36 44 44 44 44 44 44 54 54 54 54 54 54 64 64 64 64 64 64 76 76 76 76 76 76 90 90 90 90 90 90 104 104 104 104 104 104 120 120 120 120 120 120 136 136 136 136 136 136 Introduction Span ft 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 End Depth in 21.8 18.6 15.5 12.4 9.3 6.1 26.6 23.5 20.4 17.3 14.1 11.0 28.4 25.3 22.1 19.0 12.8 6.5 38.4 35.3 32.1 29.0 22.8 16.5 45.3 42.1 39.0 32.8 26.5 14.0 57.3 54.1 51.0 44.8 38.5 26.0 68.1 65.0 58.8 52.5 40.0 15.0 82.1 79.0 72.8 66.5 54.0 29.0 95.0 88.8 82.5 70.0 45.0 20.0 111.0 104.8 98.5 86.0 61.0 36.0 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 29 Introduction Gable Joist (SPGB) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 End Depth in 24.5 20.8 17.0 13.3 9.5 5.8 28.8 25.0 21.3 17.5 13.8 10.0 31.3 27.5 23.8 20.0 12.5 5.0 41.3 37.5 33.8 30.0 22.5 15.0 49.5 45.8 42.0 34.5 27.0 12.0 63.5 59.8 56.0 48.5 41.0 26.0 73.8 70.0 62.5 55.0 40.0 10.0 89.8 86.0 78.5 71.0 56.0 26.0 102.0 94.5 87.0 72.0 42.0 12.0 118.0 110.5 103.0 88.0 58.0 28.0 Center Depth in 32 32 32 32 32 32 40 40 40 40 40 40 50 50 50 50 50 50 60 60 60 60 60 60 72 72 72 72 72 72 86 86 86 86 86 86 100 100 100 100 100 100 116 116 116 116 116 116 132 132 132 132 132 132 148 148 148 148 148 148 Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.375 0.500 0.625 0.750 0.875 1.000 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.875 1.000 1.250 1.500 2.000 3.000 0.875 1.000 1.250 1.500 2.000 3.000 1.000 1.250 1.500 2.000 3.000 4.000 1.000 1.250 1.500 2.000 3.000 4.000 Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 17 18 18 19 21 23 15 15 16 16 17 18 14 14 14 14 15 17 14 14 14 14 14 14 15 15 15 14 14 14 16 16 15 15 15 15 23 22 22 21 22 21 27 26 25 24 23 23 31 30 29 28 25 24 36 36 34 32 30 28 20 21 21 22 25 28 17 18 18 19 19 20 16 16 16 16 17 19 15 15 15 15 15 15 16 16 16 15 15 15 17 17 16 16 16 16 23 22 22 22 22 21 28 27 25 25 24 23 32 30 29 28 25 24 36 38 35 32 30 28 25 25 25 25 28 29 19 20 20 20 21 22 18 18 18 18 19 22 16 16 17 17 16 17 17 17 17 17 16 17 18 18 17 17 17 17 23 23 23 22 22 22 28 27 25 25 24 23 34 31 30 28 26 25 37 38 36 33 30 28 26 28 27 29 31 34 22 22 21 23 24 26 20 19 19 20 20 25 18 18 18 19 18 19 17 17 18 18 18 19 19 19 18 18 17 18 24 24 23 23 22 22 29 27 26 25 25 23 34 32 31 28 26 25 37 39 36 34 31 28 29 29 30 32 34 38 24 24 25 25 26 28 21 21 21 21 23 29 19 19 20 20 20 20 19 19 19 19 19 20 21 19 20 20 19 18 24 24 23 23 22 23 30 29 28 27 25 24 35 33 32 30 27 26 39 40 38 35 31 28 32 31 32 35 38 42 26 26 28 28 29 32 23 23 23 24 26 30 21 21 21 21 21 21 20 20 20 20 19 21 21 21 21 20 20 20 25 25 24 24 23 23 30 29 29 27 25 24 36 33 32 30 27 26 40 42 39 35 32 31 34 36 36 38 41 52 28 28 29 29 31 32 24 25 26 26 29 32 22 22 22 22 23 24 21 21 21 20 21 22 23 23 22 21 21 21 26 25 25 24 24 23 30 29 29 29 27 25 38 34 32 31 27 26 41 42 40 35 33 31 37 37 39 41 47 52 30 31 31 32 34 37 26 26 27 28 30 35 24 24 24 24 25 26 23 22 23 22 22 24 24 24 24 22 22 22 27 26 25 25 25 24 31 30 29 29 28 27 39 34 33 31 29 29 41 43 42 37 34 31 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 30 700 750 800 40 40 41 51 51 57 33 33 33 35 37 40 28 29 28 29 32 37 24 24 25 25 26 27 25 25 24 25 24 26 25 25 25 26 24 23 28 29 27 26 26 24 33 32 31 30 28 27 39 36 33 33 30 29 41 43 42 37 34 31 46 46 50 51 51 60 34 36 36 36 39 42 29 31 31 32 33 40 26 26 27 27 27 29 25 25 25 25 25 27 27 27 26 26 25 25 29 29 28 28 27 26 34 32 31 30 28 28 39 37 35 33 30 29 43 44 42 38 34 32 50 50 51 51 57 60 37 38 38 39 42 48 32 32 33 34 37 42 28 29 29 28 29 31 27 26 27 26 26 28 28 28 28 26 26 25 29 29 29 28 27 26 35 34 33 31 29 28 40 37 37 33 30 29 47 46 43 40 35 32 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Gable Joist (SPGB) Tables Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 50 50 51 55 60 68 38 39 40 42 48 51 33 33 34 35 38 48 30 30 30 30 30 32 30 29 29 28 28 30 30 29 29 29 27 28 32 31 31 30 29 29 36 36 34 33 32 31 42 41 39 38 35 31 53 44 42 40 34 33 55 55 58 59 63 76 40 41 42 46 51 52 35 35 35 37 39 52 32 32 32 32 33 33 31 31 31 31 30 31 32 32 31 31 29 29 35 32 32 33 32 31 36 38 38 33 34 31 44 41 40 39 36 32 53 44 43 41 35 33 58 58 58 63 67 82 47 46 51 51 51 52 37 37 37 38 43 52 33 34 34 33 34 35 33 32 32 32 33 34 33 32 33 32 32 31 35 33 35 33 33 33 38 38 38 37 35 34 47 43 41 40 38 35 54 47 44 42 37 36 Joist Self-Weight - Pounds per Linear Foot (plf) 25 25 26 28 29 32 21 20 21 22 22 25 20 20 20 20 20 22 21 20 20 20 20 20 21 21 21 21 21 21 24 23 23 22 22 22 27 26 25 24 23 23 28 28 29 27 26 24 36 36 32 30 30 26 40 38 36 32 29 27 29 28 29 30 32 38 23 24 24 25 26 28 21 21 21 21 22 26 21 21 21 21 21 21 22 22 22 21 21 21 24 23 23 23 23 22 27 26 26 24 23 23 29 31 29 28 27 25 36 36 33 33 30 27 42 38 37 34 30 29 32 31 32 34 38 42 26 26 26 28 29 29 23 22 23 23 25 29 21 22 21 21 22 22 23 23 22 22 22 22 24 23 24 23 23 23 27 26 26 25 24 23 31 31 30 29 27 26 37 36 34 34 31 27 43 38 37 35 30 29 35 35 35 37 41 52 29 28 29 30 31 32 24 25 25 26 27 32 23 23 23 22 22 23 23 24 23 23 23 23 25 25 24 24 23 23 27 27 27 26 25 24 31 31 32 29 28 26 39 38 34 35 32 28 44 41 38 36 32 29 39 39 39 41 52 52 30 31 32 32 34 37 26 27 27 27 29 35 24 24 24 24 24 25 25 25 25 24 24 24 27 25 25 25 24 24 30 30 28 27 26 25 31 33 32 31 29 27 40 38 35 35 33 29 44 41 40 37 32 31 45 46 46 51 52 60 33 33 34 37 37 40 29 29 29 29 32 38 25 25 25 26 27 27 26 26 26 25 25 26 28 27 27 26 26 25 30 30 29 28 27 26 32 34 32 31 30 27 40 39 36 35 33 30 46 42 41 37 33 31 50 50 50 51 57 64 36 36 37 38 40 41 31 31 31 32 35 41 27 27 27 27 28 29 27 27 26 26 26 29 28 28 28 27 26 26 30 30 30 29 28 27 34 36 32 32 30 29 42 41 38 37 34 30 48 43 42 37 33 32 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 21 21 22 24 25 29 20 20 20 19 20 20 20 20 20 20 20 20 20 20 20 20 20 20 21 21 21 21 21 20 23 23 23 22 22 21 25 24 25 24 23 22 28 28 27 26 26 24 34 32 31 30 28 26 40 37 34 32 29 27 SP-Series Design Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.375 0.500 0.625 0.750 0.875 1.000 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.875 1.000 1.250 1.500 2.000 3.000 0.875 1.000 1.250 1.500 2.000 3.000 0.875 1.000 1.250 1.500 2.000 3.000 1.000 1.250 1.500 2.000 3.000 4.000 Special Profile Joists Center Depth in 36 36 36 36 36 36 46 46 46 46 46 46 58 58 58 58 58 58 70 70 70 70 70 70 84 84 84 84 84 84 98 98 98 98 98 98 112 112 112 112 112 112 126 126 126 126 126 126 140 140 140 140 140 140 154 154 154 154 154 154 Introduction Span ft 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 End Depth in 27.3 22.9 18.5 14.1 9.8 5.4 32.9 28.5 24.1 19.8 15.4 11.0 36.1 31.8 27.4 23.0 14.3 5.5 48.1 43.8 39.4 35.0 26.3 17.5 57.8 53.4 49.0 40.3 31.5 14.0 71.8 67.4 63.0 54.3 45.5 28.0 81.4 77.0 68.3 59.5 42.0 7.0 95.4 91.0 82.3 73.5 56.0 21.0 109.4 105.0 96.3 87.5 70.0 35.0 119.0 110.3 101.5 84.0 49.0 14.0 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 31 Introduction Gable Joist (SPGB) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 End Depth in 30.0 25.0 20.0 15.0 10.0 5.0 35.0 30.0 25.0 20.0 15.0 10.0 42.0 37.0 32.0 27.0 22.0 12.0 51.0 46.0 41.0 36.0 26.0 16.0 60.0 55.0 50.0 40.0 30.0 10.0 74.0 69.0 64.0 54.0 44.0 24.0 88.0 83.0 78.0 68.0 58.0 38.0 97.0 92.0 82.0 72.0 52.0 12.0 111.0 106.0 96.0 86.0 66.0 26.0 125.0 120.0 110.0 100.0 80.0 40.0 Center Depth in 40 40 40 40 40 40 50 50 50 50 50 50 62 62 62 62 62 62 76 76 76 76 76 76 90 90 90 90 90 90 104 104 104 104 104 104 118 118 118 118 118 118 132 132 132 132 132 132 146 146 146 146 146 146 160 160 160 160 160 160 Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.375 0.500 0.625 0.750 0.875 1.000 0.500 0.625 0.750 0.875 1.000 1.250 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.875 1.000 1.250 1.500 2.000 3.000 0.875 1.000 1.250 1.500 2.000 3.000 0.875 1.000 1.250 1.500 2.000 3.000 Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 26 26 26 28 29 34 21 21 22 22 23 26 21 21 21 20 20 21 21 21 21 20 20 21 22 22 22 21 21 21 24 23 23 23 22 22 28 27 27 26 24 24 31 30 29 27 26 25 33 33 34 32 29 27 41 40 37 38 34 29 30 30 31 32 34 39 25 26 26 26 28 29 22 21 22 21 23 25 21 21 21 21 21 21 22 22 22 22 21 22 24 24 24 23 23 22 28 27 27 26 25 24 31 31 30 29 27 25 35 34 35 34 31 27 42 40 38 40 35 31 34 35 34 36 40 52 28 28 28 30 30 33 23 24 25 24 26 29 23 22 23 22 23 23 23 23 23 22 22 22 26 25 25 24 24 23 28 29 28 27 26 25 33 32 30 30 28 25 36 35 35 34 31 27 43 42 39 40 36 32 38 38 39 41 52 52 30 30 31 33 34 37 27 27 26 27 28 30 24 24 24 24 24 27 25 24 25 24 24 26 27 26 26 25 25 24 29 30 28 28 26 26 34 33 32 31 28 27 37 35 37 34 34 30 45 43 41 41 38 32 44 46 46 51 52 60 33 34 34 37 39 41 29 29 29 29 30 33 26 26 27 26 27 30 26 26 25 25 25 28 29 28 27 26 26 25 31 30 30 29 29 27 34 33 33 31 30 28 38 37 37 34 34 30 46 45 42 42 38 34 50 50 51 51 55 67 36 37 38 40 42 51 32 32 32 32 33 38 29 28 28 29 30 32 28 27 28 28 28 31 29 28 28 27 27 27 31 31 31 30 29 28 35 34 33 32 31 28 39 37 39 36 34 30 47 45 44 43 38 35 50 50 51 54 60 67 40 40 41 42 52 52 33 35 35 35 38 41 31 31 31 31 33 33 30 30 31 30 30 32 31 30 31 29 29 29 33 32 31 32 31 29 37 35 34 33 32 30 41 39 39 37 35 32 47 47 44 43 39 36 57 58 58 59 67 82 42 47 51 51 52 53 36 36 38 37 39 43 33 33 33 34 33 36 32 32 32 31 32 36 33 33 32 32 30 31 36 35 33 33 33 32 39 37 36 35 35 32 42 41 42 39 38 33 49 49 44 43 41 37 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 32 700 750 800 62 62 62 66 67 85 51 50 51 52 52 60 38 38 39 41 42 52 35 35 35 35 36 39 34 34 35 34 34 36 35 35 34 33 33 33 38 35 36 35 35 34 41 40 38 38 36 35 42 45 43 41 40 35 54 54 46 48 41 38 65 65 66 66 75 98 51 51 51 52 59 60 42 41 43 47 47 52 38 37 37 38 39 41 36 35 36 37 36 40 36 36 36 34 35 35 38 37 36 37 35 36 42 41 40 38 38 35 44 45 44 42 40 37 54 54 49 49 44 40 70 70 70 74 85 106 51 52 55 59 59 67 48 48 47 52 52 52 39 39 39 40 42 44 38 38 38 37 38 43 39 38 37 37 36 36 41 39 39 38 38 37 43 42 41 41 39 38 47 46 45 42 42 39 55 54 52 49 45 42 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Gable Joist (SPGB) Tables Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 66 65 66 66 75 85 52 51 52 56 60 60 43 42 48 47 48 53 40 40 39 40 41 42 39 38 39 38 38 44 39 39 39 38 38 38 41 40 41 40 39 38 45 44 43 42 40 40 52 51 46 45 45 41 58 56 54 48 46 44 71 70 69 74 85 103 56 56 59 59 60 67 49 49 49 53 53 53 43 42 42 42 43 50 41 40 42 41 40 49 42 41 41 39 40 41 45 44 42 40 41 40 46 44 46 43 41 42 53 51 48 48 46 42 59 57 56 50 49 44 73 73 74 80 85 103 60 60 59 59 67 67 53 53 53 53 53 61 49 48 48 47 48 53 44 43 44 44 44 54 43 43 43 41 41 43 46 45 45 44 43 42 50 49 46 45 43 44 55 54 51 48 48 44 60 59 57 56 53 47 Joist Self-Weight - Pounds per Linear Foot (plf) 32 32 32 34 37 42 27 27 28 28 30 32 24 24 24 24 25 27 25 24 24 24 24 25 25 25 25 25 24 24 28 28 28 27 27 25 32 31 31 30 29 28 35 34 34 32 30 28 39 40 38 35 34 31 46 42 43 40 36 33 36 36 38 40 41 52 30 30 31 32 33 34 26 26 27 27 27 30 25 25 25 25 25 26 26 26 26 25 25 26 28 29 28 27 27 26 32 32 31 31 30 28 35 34 34 33 31 29 39 41 38 37 34 31 48 44 44 40 36 34 40 40 41 51 51 56 33 33 34 35 37 40 29 30 30 29 31 32 27 28 27 27 28 30 27 27 26 26 26 29 30 29 29 28 27 27 33 32 32 31 30 29 36 35 34 34 31 29 41 43 39 37 36 32 48 46 46 43 39 35 46 50 50 51 51 59 37 37 37 38 41 47 33 32 33 32 32 35 31 31 30 30 30 32 30 29 29 29 28 32 31 30 30 29 29 29 34 33 33 32 30 30 38 38 35 34 32 31 43 45 39 37 36 34 49 47 48 45 41 35 50 50 51 56 60 67 40 40 40 42 46 52 35 36 36 35 37 39 34 33 33 33 34 35 32 32 32 32 31 34 34 33 33 32 31 32 36 35 35 35 33 32 40 40 37 36 33 34 44 46 41 39 38 35 51 48 48 46 42 41 54 54 59 59 66 76 48 47 51 51 52 52 38 37 39 38 39 43 36 36 35 35 36 38 35 34 34 34 34 37 36 35 35 34 34 35 39 38 37 37 36 35 42 41 40 38 37 36 47 46 46 42 40 36 58 49 49 47 43 41 58 58 59 66 66 85 51 51 52 52 52 60 40 40 42 41 41 53 37 37 38 38 38 40 37 37 39 37 36 40 38 37 37 36 36 37 41 39 39 38 37 37 43 41 43 40 38 38 50 49 46 45 42 38 58 52 51 48 44 41 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 28 28 30 29 32 37 23 24 24 25 26 27 23 23 23 22 23 24 24 24 24 24 24 23 25 25 25 25 24 24 28 28 28 27 26 25 32 31 30 30 28 27 35 34 34 32 30 28 38 36 37 35 33 30 44 41 40 40 36 33 SP-Series Design Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.375 0.500 0.625 0.750 0.875 1.000 0.500 0.625 0.750 0.875 1.000 1.250 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.875 1.000 1.250 1.500 2.000 3.000 0.875 1.000 1.250 1.500 2.000 3.000 0.875 1.000 1.250 1.500 2.000 3.000 Special Profile Joists Center Depth in 46 46 46 46 46 46 58 58 58 58 58 58 72 72 72 72 72 72 86 86 86 86 86 86 100 100 100 100 100 100 114 114 114 114 114 114 128 128 128 128 128 128 142 142 142 142 142 142 156 156 156 156 156 156 170 170 170 170 170 170 Introduction Span ft 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 End Depth in 34.8 29.1 23.5 17.9 12.3 6.6 41.1 35.5 29.9 24.3 18.6 13.0 49.5 43.9 38.3 32.6 27.0 15.8 57.9 52.3 46.6 41.0 29.8 18.5 66.3 60.6 55.0 43.8 32.5 10.0 80.3 74.6 69.0 57.8 46.5 24.0 94.3 88.6 83.0 71.8 60.5 38.0 102.6 97.0 85.8 74.5 52.0 7.0 116.6 111.0 99.8 88.5 66.0 21.0 130.6 125.0 113.8 102.5 80.0 35.0 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 33 Introduction Gable Joist (SPGB) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 End Depth in 37.5 31.3 25.0 18.8 12.5 6.3 43.3 37.0 30.8 24.5 18.3 12.0 51.0 44.8 38.5 32.3 26.0 13.5 58.8 52.5 46.3 40.0 27.5 15.0 72.8 66.5 60.3 54.0 41.5 29.0 80.5 74.3 68.0 55.5 43.0 18.0 94.5 88.3 82.0 69.5 57.0 32.0 108.5 102.3 96.0 83.5 71.0 46.0 116.3 110.0 97.5 85.0 60.0 10.0 130.3 124.0 111.5 99.0 74.0 24.0 Center Depth in 50 50 50 50 50 50 62 62 62 62 62 62 76 76 76 76 76 76 90 90 90 90 90 90 104 104 104 104 104 104 118 118 118 118 118 118 132 132 132 132 132 132 146 146 146 146 146 146 160 160 160 160 160 160 174 174 174 174 174 174 Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.375 0.500 0.625 0.750 0.875 1.000 0.500 0.625 0.750 0.875 1.000 1.250 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.875 1.000 1.250 1.500 2.000 3.000 0.875 1.000 1.250 1.500 2.000 3.000 Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 32 32 32 34 37 41 27 27 28 28 30 32 25 24 24 24 25 27 25 25 24 24 24 25 27 26 26 25 25 25 29 28 28 27 27 26 32 31 31 30 29 28 37 35 35 34 32 30 40 39 38 35 33 31 44 44 41 39 38 32 36 36 38 40 41 52 30 30 31 31 33 38 28 27 27 28 29 31 25 25 26 26 27 28 27 27 26 26 26 25 30 29 28 28 27 26 32 31 32 30 30 28 37 35 35 34 32 31 40 39 39 37 35 31 46 46 41 41 39 34 45 47 46 50 51 60 34 34 34 37 39 42 30 30 30 31 32 35 28 28 29 28 30 32 28 28 27 27 28 28 31 30 30 29 28 29 34 33 33 31 30 29 37 37 36 35 34 31 41 41 40 38 35 32 48 48 45 41 39 35 50 50 50 51 56 63 37 39 38 40 42 52 34 33 33 35 35 39 31 32 32 31 33 35 31 31 32 31 31 31 32 32 32 31 31 31 35 34 34 33 31 31 41 38 37 36 34 32 44 42 40 40 36 34 49 48 46 43 40 36 54 55 55 59 60 73 42 42 47 47 51 52 37 37 38 38 38 42 35 36 35 35 36 39 34 33 34 34 34 34 35 35 35 34 33 33 38 36 37 35 35 33 43 38 40 38 37 36 46 44 42 42 38 36 49 51 49 45 42 38 58 58 59 63 67 81 51 51 51 51 51 60 39 39 42 42 43 52 37 39 38 37 39 42 36 36 37 36 37 36 37 37 37 36 36 36 40 39 38 37 36 36 45 40 41 41 38 37 47 46 46 44 41 39 52 51 49 50 45 40 63 62 66 66 75 84 52 51 52 56 59 60 43 42 48 48 52 53 40 40 41 40 42 49 39 38 38 38 39 39 40 39 39 38 39 39 42 40 40 39 38 38 46 43 43 42 41 40 48 47 46 45 43 40 57 54 51 50 47 42 71 70 71 75 85 103 56 56 59 60 59 67 49 48 53 52 52 57 43 43 44 43 48 54 41 42 42 41 41 43 40 41 41 42 41 42 43 42 42 41 41 41 48 46 45 44 43 42 50 49 50 47 46 43 58 56 53 51 47 44 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 34 700 750 800 74 73 74 80 85 119 59 59 59 64 68 75 54 53 53 53 53 61 49 48 50 50 53 54 44 44 44 44 44 44 43 43 43 42 43 45 46 45 46 44 44 42 50 48 48 46 45 43 53 53 50 49 46 46 59 57 59 55 49 46 82 83 83 84 103 128 63 64 67 67 71 81 55 54 57 56 60 65 50 50 50 54 54 58 49 48 48 49 48 50 47 46 46 46 46 51 49 47 46 46 44 46 50 50 49 49 46 45 58 57 57 54 48 48 59 62 59 56 57 52 92 92 93 100 103 128 67 67 68 72 74 85 58 57 61 61 61 69 55 55 54 55 55 62 51 51 50 50 51 55 50 50 49 49 49 51 52 52 54 51 51 50 57 55 55 54 53 52 59 58 57 57 51 52 64 63 61 58 57 52 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Gable Joist (SPGB) Tables Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 79 79 82 84 103 120 64 68 67 67 75 82 58 58 61 61 61 72 55 55 55 55 58 69 52 52 52 51 55 55 50 50 51 51 51 63 52 51 50 50 50 52 53 51 52 52 51 51 57 53 55 51 53 52 59 58 59 56 52 53 83 84 83 101 103 127 68 68 71 76 80 86 62 62 62 64 68 77 59 59 58 58 62 70 53 52 56 56 56 59 53 52 52 53 57 64 53 52 53 51 52 56 54 55 53 52 51 53 58 56 55 55 54 52 61 60 59 57 57 55 93 93 100 101 117 127 72 75 75 80 85 95 65 66 65 69 71 87 59 60 63 63 66 77 58 60 60 59 59 62 55 55 54 57 58 67 56 55 54 54 54 58 56 55 54 54 52 54 58 59 58 56 55 54 62 61 60 60 58 55 Joist Self-Weight - Pounds per Linear Foot (plf) 39 39 39 41 52 51 34 33 34 35 37 40 30 30 30 31 32 38 29 29 29 29 30 35 31 30 29 29 29 29 32 31 30 30 30 32 34 34 34 32 31 31 37 37 36 34 34 32 42 40 39 38 36 34 45 45 43 42 39 37 46 46 50 51 52 60 38 37 38 40 42 52 34 34 35 36 38 41 32 32 32 33 33 38 33 32 32 31 31 33 33 33 33 31 32 36 36 35 35 34 33 32 40 38 37 35 35 34 42 41 40 39 37 36 48 45 44 43 40 38 51 50 51 54 59 67 41 42 47 48 52 52 38 39 39 38 42 53 36 36 37 37 40 44 36 35 35 34 35 37 36 36 35 34 34 40 38 37 37 37 35 35 41 40 39 37 37 35 45 43 42 41 39 37 48 47 46 44 43 41 55 59 59 59 67 76 52 52 51 51 52 60 42 42 42 43 48 53 40 39 40 40 42 53 39 38 37 37 38 40 38 38 38 38 37 43 39 39 38 37 38 38 43 41 40 40 39 38 45 45 43 42 42 39 49 48 47 46 44 43 63 62 62 66 71 85 52 52 52 55 60 64 49 48 49 52 53 61 43 43 43 43 49 54 42 41 41 40 41 43 40 40 39 39 40 50 41 41 41 40 41 41 44 44 42 40 40 41 48 46 45 43 42 40 50 48 48 47 44 43 66 66 66 75 81 102 56 56 59 59 64 67 54 54 53 53 53 61 48 50 50 50 53 58 45 43 44 43 44 49 43 43 42 42 43 55 45 44 44 43 44 44 46 44 45 43 42 42 49 49 48 45 44 43 52 51 50 49 47 45 73 73 74 80 85 102 60 60 60 64 67 75 54 54 58 58 59 68 50 50 54 54 54 62 50 50 49 48 50 54 45 45 45 45 49 55 47 46 47 46 46 51 49 48 48 46 46 46 52 52 51 48 48 46 58 54 53 52 50 48 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 34 34 34 36 40 47 29 29 30 31 32 34 28 27 27 27 29 33 28 28 28 28 28 30 29 28 28 28 28 28 31 30 30 29 28 29 34 32 32 31 30 29 35 36 35 33 33 31 39 38 37 37 35 33 44 43 42 40 39 36 SP-Series Design Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.375 0.500 0.625 0.750 0.875 1.000 0.500 0.625 0.750 0.875 1.000 1.250 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 Special Profile Joists Center Depth in 56 56 56 56 56 56 68 68 68 68 68 68 80 80 80 80 80 80 92 92 92 92 92 92 104 104 104 104 104 104 116 116 116 116 116 116 128 128 128 128 128 128 140 140 140 140 140 140 152 152 152 152 152 152 164 164 164 164 164 164 Introduction Span ft 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 End Depth in 42.3 35.4 28.5 21.6 14.8 7.9 47.4 40.5 33.6 26.8 19.9 13.0 52.5 45.6 38.8 31.9 25.0 11.3 57.6 50.8 43.9 37.0 23.3 9.5 69.6 62.8 55.9 49.0 35.3 21.5 74.8 67.9 61.0 47.3 33.5 6.0 86.8 79.9 73.0 59.3 45.5 18.0 98.8 91.9 85.0 71.3 57.5 30.0 110.8 103.9 97.0 83.3 69.5 42.0 122.8 115.9 109.0 95.3 81.5 54.0 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 35 Introduction Gable Joist (SPGB) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 End Depth in 45.0 37.5 30.0 22.5 15.0 7.5 49.5 42.0 34.5 27.0 19.5 12.0 54.0 46.5 39.0 31.5 24.0 9.0 58.5 51.0 43.5 36.0 21.0 6.0 70.5 63.0 55.5 48.0 33.0 18.0 82.5 75.0 67.5 60.0 45.0 30.0 87.0 79.5 72.0 57.0 42.0 12.0 99.0 91.5 84.0 69.0 54.0 24.0 111.0 103.5 96.0 81.0 66.0 36.0 123.0 115.5 108.0 93.0 78.0 48.0 Center Depth in 60 60 60 60 60 60 72 72 72 72 72 72 84 84 84 84 84 84 96 96 96 96 96 96 108 108 108 108 108 108 120 120 120 120 120 120 132 132 132 132 132 132 144 144 144 144 144 144 156 156 156 156 156 156 168 168 168 168 168 168 Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.375 0.500 0.625 0.750 0.875 1.000 0.500 0.625 0.750 0.875 1.000 1.250 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 38 38 38 40 47 52 33 32 33 35 37 40 30 30 30 31 33 38 29 29 29 29 31 36 30 30 30 29 29 30 32 32 31 31 30 30 34 34 34 32 31 31 38 37 36 35 33 31 42 40 39 38 35 34 46 45 43 40 40 37 46 46 51 51 51 60 38 38 37 40 42 52 34 34 36 36 38 43 32 32 32 34 35 42 33 32 32 31 32 34 35 33 34 32 32 32 36 35 35 34 33 34 39 38 37 36 35 33 43 41 42 39 38 36 46 45 44 43 41 38 51 50 51 55 59 67 42 43 48 52 52 52 39 39 38 40 41 53 37 36 38 37 39 53 36 36 35 36 35 37 36 36 36 35 35 36 38 37 37 36 34 37 41 40 40 38 37 36 46 44 43 42 40 38 48 47 47 45 42 40 58 58 59 59 67 75 52 52 52 52 52 59 43 42 44 49 53 57 40 40 40 40 44 53 39 39 40 40 39 43 39 39 38 39 38 39 42 39 40 41 38 41 44 43 42 42 39 40 47 46 47 43 41 40 49 48 48 48 44 42 62 62 66 67 75 85 53 52 56 60 60 68 49 48 52 53 53 61 44 44 43 49 54 61 43 42 43 43 44 50 42 41 41 41 41 42 42 41 41 41 40 46 45 43 43 42 41 41 47 46 47 43 43 42 52 50 48 48 45 43 70 70 71 75 84 103 60 59 60 60 68 72 54 53 54 53 57 68 50 50 49 54 54 66 45 46 46 48 50 55 45 45 45 44 45 45 45 44 44 44 45 51 48 46 46 45 44 45 50 50 49 46 46 45 53 51 51 50 48 45 75 79 80 83 84 103 61 64 64 67 72 82 58 57 57 61 60 77 54 55 55 55 58 68 50 51 51 51 55 55 51 51 50 51 50 51 49 48 47 47 49 57 50 50 49 49 48 52 53 54 52 50 49 48 60 58 54 52 51 49 84 83 84 83 103 127 68 68 68 75 82 86 62 62 61 65 69 81 56 58 59 58 62 76 53 52 57 56 56 59 53 52 53 53 52 56 52 53 52 53 51 58 56 54 53 52 51 53 57 56 56 54 54 52 61 59 58 58 56 55 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 36 700 750 800 93 93 93 100 116 127 72 75 75 80 85 104 65 65 65 69 73 86 60 59 63 62 66 87 58 58 57 59 60 63 55 55 54 54 57 57 55 55 55 55 55 61 57 56 55 53 54 54 60 58 57 55 54 54 62 61 61 58 57 55 99 100 101 100 126 127 76 80 81 85 95 104 69 70 72 73 76 103 63 66 66 65 69 87 62 60 61 60 64 67 60 62 62 62 61 60 58 57 57 56 59 66 58 57 57 57 57 60 62 60 61 57 57 56 66 63 61 59 59 56 100 101 101 117 126 150 86 84 84 94 104 117 73 73 76 76 82 103 68 67 67 70 78 104 63 62 65 65 66 71 63 63 63 62 61 65 61 60 65 63 63 69 63 59 62 59 60 63 62 64 61 61 60 61 68 66 63 63 60 58 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Gable Joist (SPGB) Tables Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 92 100 101 102 117 127 80 80 85 85 96 104 70 72 73 77 82 104 67 68 67 67 70 74 62 62 62 65 68 71 63 63 63 62 62 65 61 60 58 63 64 73 61 62 58 60 60 63 64 62 61 60 59 62 66 64 63 61 61 60 101 101 101 114 125 140 85 86 85 95 103 118 74 76 77 82 87 104 68 68 71 71 73 83 69 68 68 68 71 79 66 64 65 63 69 68 66 65 65 64 64 77 66 65 63 66 65 64 69 66 65 62 63 65 71 68 67 64 64 62 114 114 113 123 125 149 86 94 102 102 103 126 82 81 82 86 95 116 75 74 75 74 78 87 70 70 70 70 75 84 68 67 67 70 69 72 67 66 65 65 71 80 71 69 69 67 67 70 70 69 67 67 67 67 72 70 69 69 68 68 Joist Self-Weight - Pounds per Linear Foot (plf) 51 51 51 51 56 59 41 41 41 42 52 52 38 38 39 38 42 53 36 36 36 36 37 39 36 36 35 35 36 37 37 37 36 35 36 36 38 38 37 36 34 38 43 41 41 39 38 36 47 45 43 42 40 37 49 49 47 45 43 40 55 55 55 59 59 67 48 52 52 52 53 60 43 42 42 44 48 53 40 40 40 40 40 43 40 39 39 40 39 43 40 39 39 39 39 39 41 40 40 39 40 43 44 44 42 41 40 39 48 47 46 44 41 40 49 49 48 45 46 42 59 60 59 66 67 80 53 53 53 56 60 64 49 49 53 53 53 61 43 44 44 44 50 54 43 43 44 44 44 50 43 43 42 43 42 42 43 42 43 42 43 48 46 45 45 43 43 43 49 48 47 45 44 43 51 49 50 48 47 44 67 67 66 71 82 85 57 60 60 60 65 73 54 54 53 54 58 68 50 50 50 49 54 54 49 50 50 49 50 55 47 46 46 46 46 49 47 46 47 46 46 57 49 50 47 47 46 47 51 50 50 48 48 48 54 53 52 51 50 48 74 73 74 80 84 103 61 65 65 68 72 81 58 58 58 61 61 76 56 56 56 55 55 62 52 52 51 51 55 60 52 51 52 52 52 52 52 52 52 50 51 58 55 53 55 52 51 52 55 53 54 51 53 53 57 58 57 56 53 53 80 79 83 84 103 120 69 68 68 76 80 86 62 63 62 66 69 82 59 59 59 59 58 65 58 58 57 57 59 63 54 53 54 53 57 57 54 53 54 53 54 61 55 55 55 54 53 55 60 58 56 55 54 55 63 60 60 57 58 55 84 84 84 102 103 127 72 75 76 81 86 104 66 65 69 69 73 85 60 60 63 63 66 69 61 61 60 60 64 68 57 55 60 59 61 61 56 55 57 56 59 66 58 57 56 57 55 60 61 59 59 56 56 57 64 63 61 60 58 55 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 40 40 40 47 51 51 36 36 36 37 40 43 34 33 33 33 36 41 32 31 32 32 31 33 34 32 32 31 32 33 35 34 34 33 32 32 37 36 36 34 33 33 40 40 38 37 35 34 44 42 43 40 38 36 48 45 44 42 42 38 SP-Series Design Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.375 0.500 0.625 0.750 0.875 1.000 0.500 0.625 0.750 0.875 1.000 1.250 0.500 0.625 0.750 0.875 1.000 1.250 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 Special Profile Joists Center Depth in 66 66 66 66 66 66 78 78 78 78 78 78 90 90 90 90 90 90 102 102 102 102 102 102 114 114 114 114 114 114 126 126 126 126 126 126 138 138 138 138 138 138 150 150 150 150 150 150 162 162 162 162 162 162 174 174 174 174 174 174 Introduction Span ft 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 End Depth in 49.8 41.6 33.5 25.4 17.3 9.1 53.6 45.5 37.4 29.3 21.1 13.0 57.5 49.4 41.3 33.1 25.0 8.8 69.5 61.4 53.3 45.1 37.0 20.8 73.4 65.3 57.1 49.0 32.8 16.5 85.4 77.3 69.1 61.0 44.8 28.5 89.3 81.1 73.0 56.8 40.5 8.0 101.3 93.1 85.0 68.8 52.5 20.0 113.3 105.1 97.0 80.8 64.5 32.0 125.3 117.1 109.0 92.8 76.5 44.0 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 37 Introduction Gable Joist (SPGB) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 End Depth in 52.5 43.8 35.0 26.3 17.5 8.8 55.8 47.0 38.3 29.5 20.8 12.0 67.8 59.0 50.3 41.5 32.8 24.0 71.0 62.3 53.5 44.8 36.0 18.5 74.3 65.5 56.8 48.0 30.5 13.0 86.3 77.5 68.8 60.0 42.5 25.0 98.3 89.5 80.8 72.0 54.5 37.0 101.5 92.8 84.0 66.5 49.0 14.0 113.5 104.8 96.0 78.5 61.0 26.0 125.5 116.8 108.0 90.5 73.0 38.0 Center Depth in 70 70 70 70 70 70 82 82 82 82 82 82 94 94 94 94 94 94 106 106 106 106 106 106 118 118 118 118 118 118 130 130 130 130 130 130 142 142 142 142 142 142 154 154 154 154 154 154 166 166 166 166 166 166 178 178 178 178 178 178 Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.375 0.500 0.625 0.750 0.875 1.000 0.375 0.500 0.625 0.750 0.875 1.000 0.500 0.625 0.750 0.875 1.000 1.250 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 0.750 0.875 1.000 1.250 1.500 2.000 Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 48 47 51 51 52 59 39 38 41 41 47 52 36 37 37 37 38 39 35 36 35 35 35 40 35 35 35 35 35 38 37 37 36 35 34 35 40 39 38 37 36 35 43 41 40 39 37 36 46 45 43 42 40 37 50 48 46 44 43 39 52 51 52 55 59 67 48 48 52 52 53 57 41 41 42 42 44 48 40 40 40 40 40 44 40 39 39 40 40 43 41 39 39 39 39 40 42 41 40 39 39 39 44 42 42 40 39 41 48 46 46 44 42 41 52 50 49 46 45 42 59 59 59 63 67 81 53 53 53 56 60 64 50 49 49 53 53 52 44 44 44 44 49 54 43 43 43 44 44 55 44 43 43 43 42 44 45 43 43 43 42 43 46 45 45 43 43 45 49 48 48 45 44 44 55 52 50 50 47 44 67 67 66 71 75 85 57 57 60 61 67 72 54 54 54 54 54 62 51 50 50 54 54 58 51 50 50 50 51 55 47 47 47 47 47 51 48 47 48 47 46 47 49 49 48 47 46 48 51 51 50 48 48 47 56 54 52 51 50 48 74 74 74 80 85 102 62 64 65 68 72 82 59 58 58 62 61 65 56 56 56 55 58 62 53 52 52 56 56 63 53 53 52 52 53 57 54 53 53 52 53 51 57 54 54 52 52 54 57 55 55 53 55 54 61 57 59 57 54 54 79 79 85 85 103 115 69 69 72 75 81 86 63 63 63 65 68 69 60 60 60 60 62 69 59 58 58 57 59 67 55 55 54 54 58 61 56 56 55 55 55 54 57 56 55 55 54 59 59 57 58 56 55 56 65 62 61 59 57 55 94 93 94 102 103 126 76 76 79 81 85 104 66 66 69 70 73 76 64 64 64 66 67 74 62 62 61 61 64 71 62 61 61 62 62 64 59 58 57 57 60 63 60 58 58 58 57 62 62 60 59 58 58 62 66 65 63 60 60 58 101 101 101 102 126 127 81 81 84 85 103 119 74 73 73 77 77 81 68 67 67 70 71 83 63 66 68 67 68 78 65 64 64 63 62 68 66 65 65 64 64 63 64 64 63 62 65 67 66 63 65 60 61 65 71 66 68 65 63 63 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 38 700 750 800 101 101 113 125 127 148 86 86 95 102 103 126 78 78 80 82 87 86 75 74 75 74 78 87 70 70 69 69 76 83 67 66 66 70 69 73 68 67 66 66 65 70 67 69 68 67 66 71 70 68 67 65 68 67 73 72 70 66 67 68 114 113 123 125 127 148 93 101 102 102 116 126 83 83 85 86 94 104 76 76 79 79 82 98 73 72 75 75 78 89 73 72 72 72 71 75 72 71 70 69 72 71 73 72 72 70 69 76 71 70 75 71 70 73 77 72 71 72 69 71 123 123 123 126 150 172 102 101 102 116 126 128 88 88 95 95 103 104 83 83 84 83 88 105 78 78 77 77 84 105 76 76 76 74 77 80 73 75 74 74 73 78 75 73 73 71 74 80 77 76 76 74 72 75 80 79 78 76 74 73 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Gable Joist (SPGB) Tables Top Chord Uniform Load - Pounds per Linear Foot ( plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 115 113 123 125 127 150 102 103 103 116 127 127 87 87 87 95 103 103 83 83 83 87 87 104 77 77 76 79 84 88 74 74 76 76 80 90 73 73 73 73 77 80 72 71 70 73 72 75 74 73 73 71 70 73 75 75 74 73 71 76 123 123 123 126 139 150 103 103 115 127 127 142 95 95 102 103 103 117 84 88 87 96 104 118 82 84 85 84 88 99 79 79 78 81 83 106 77 76 75 79 78 86 79 78 78 77 77 79 75 75 76 77 78 75 79 76 75 74 75 81 124 123 126 136 149 172 114 114 125 127 127 150 103 104 103 104 114 128 97 96 97 104 104 127 86 86 85 89 97 105 84 86 85 85 89 107 82 82 80 80 86 91 80 79 78 80 79 83 81 81 81 80 78 80 79 79 81 80 79 85 Joist Self-Weight - Pounds per Linear Foot (plf) 56 56 56 59 64 71 53 53 53 53 56 64 50 49 49 53 54 53 45 44 44 49 50 53 43 42 42 43 44 50 44 43 42 42 43 51 44 43 42 42 42 43 45 43 43 43 42 43 47 45 45 44 43 43 47 47 46 44 43 44 61 60 63 67 71 85 57 57 60 61 64 72 55 55 54 54 56 61 51 51 55 55 54 61 50 50 50 50 50 55 47 47 47 47 51 56 48 47 47 47 47 51 48 47 47 47 46 46 50 50 48 47 46 46 50 49 48 48 47 47 68 68 70 76 80 96 62 65 64 68 72 81 58 58 58 61 61 69 56 56 56 58 58 69 53 57 57 56 55 59 52 53 52 52 56 59 52 53 53 53 53 57 56 54 53 53 53 54 55 53 55 53 53 52 57 54 52 54 51 55 75 76 80 85 96 103 70 69 73 75 82 97 63 65 66 65 69 73 60 59 63 63 66 77 58 60 61 60 60 63 59 59 58 58 59 68 56 55 55 55 58 61 57 56 55 54 55 59 58 57 56 56 56 56 59 58 58 56 56 62 84 84 84 94 103 125 77 77 81 86 85 104 70 70 70 72 77 83 67 66 66 66 70 82 62 61 64 64 65 70 63 63 62 62 65 71 64 63 63 62 62 65 60 58 59 58 61 63 61 60 59 59 58 62 61 61 60 59 59 65 93 93 100 102 116 125 81 84 86 95 104 117 74 73 77 82 82 87 72 71 74 73 78 87 69 69 68 68 71 75 64 64 67 68 68 79 65 65 65 64 67 69 67 66 65 64 64 63 66 65 64 68 65 65 67 66 66 63 66 69 101 102 101 115 127 125 85 95 102 103 115 126 82 82 81 86 87 103 75 74 78 83 83 104 70 73 74 74 75 84 72 71 70 70 75 84 69 68 70 71 70 77 69 69 67 67 67 70 70 71 69 68 67 66 69 71 71 69 67 73 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 48 51 51 52 56 59 42 42 47 47 52 56 40 40 39 42 41 48 40 39 39 40 39 49 39 38 38 38 38 40 38 38 39 39 39 40 40 39 39 39 38 38 40 41 40 39 38 37 44 43 41 41 40 38 44 44 43 42 40 40 SP-Series Design Top Chord Pitch in/ft 0.250 0.375 0.500 0.625 0.750 0.875 0.375 0.500 0.625 0.750 0.875 1.000 0.375 0.500 0.625 0.750 0.875 1.000 0.500 0.625 0.750 0.875 1.000 1.250 0.500 0.625 0.750 0.875 1.000 1.250 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.625 0.750 0.875 1.000 1.250 1.500 0.750 0.875 1.000 1.250 1.500 2.000 Special Profile Joists Center Depth in 76 76 76 76 76 76 86 86 86 86 86 86 96 96 96 96 96 96 106 106 106 106 106 106 116 116 116 116 116 116 126 126 126 126 126 126 136 136 136 136 136 136 146 146 146 146 146 146 156 156 156 156 156 156 166 166 166 166 166 166 Introduction Span ft 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 End Depth in 57.3 47.9 38.5 29.1 19.8 10.4 57.9 48.5 39.1 29.8 20.4 11.0 67.9 58.5 49.1 39.8 30.4 21.0 68.5 59.1 49.8 40.4 31.0 12.3 78.5 69.1 59.8 50.4 41.0 22.3 79.1 69.8 60.4 51.0 32.3 13.5 89.1 79.8 70.4 61.0 42.3 23.5 99.1 89.8 80.4 71.0 52.3 33.5 109.1 99.8 90.4 81.0 62.3 43.5 109.8 100.4 91.0 72.3 53.5 16.0 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 39 Bowstring Joist (SPBW) Tables Introduction BOWSTRING (SPBW) WEIGHT The following weight tables are representative of SP-Series JOISTS linear foot. This catalog provides two design TABLES examples for joist designs for Bowstring Joists are withrepresentative parameters shown in the reference andforclarification design The following The following weight tables of SP-Series joist designs Bowstring on Joists withissues. parameters shown in the diagram The maximum joistare is L/240 for a Live Load equal 75constraints percent ofon the diagram below.below. The maximum allowableallowable Live Loaddeflection deflection for the tables not representative of any limitsto or Total Load in the table. Thepercent tables of also per Section 904.5(d), theFor required depth for is L/240 for a listed Live Load equal to 75 thegive Totalbridging Load requirements design or constructability by NMBS. furtherseat information, the given profile, as well as the estimated pounds per linear foot. This catalog provides two complete design examples for listed in the table. The tables also give bridging requirements please contact your nearest NMBS representative or visit reference and clarification on design issues. The following tables are not representative of any limits or constraints on perdesign Section 904.5(d), the required seat depth for the given or constructability per NMBS. For further information,www.newmill.com. please contact your nearest NMBS representative or visit profile, as well as the estimated self-weight in pounds per www.newmill.com. Special Profile Joists ALL TABLES TABLES ARE BASED ON ASD ALL ARE BASED ON ASD Standard Specification SP-Series Tables SP-Series Design BOWSTRING JOIST (SPBW) 36 40 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Bowstring Joist (SPBW) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 9 9 9 9 9 9 8 8 8 9 9 9 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 9 9 9 9 9 11 9 9 9 9 9 11 10 10 10 10 10 11 11 11 11 11 11 11 13 12 12 12 12 13 9 9 9 9 9 9 8 8 9 9 9 9 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 9 9 9 9 9 11 9 9 9 9 9 11 10 10 10 10 10 11 11 11 11 11 11 11 13 12 12 12 12 13 9 9 9 9 9 9 8 9 9 9 9 9 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 9 9 9 9 10 11 9 9 9 9 9 11 10 10 10 10 10 11 11 11 11 11 11 11 13 12 12 12 12 13 Joist Self-Weight - Pounds per Linear Foot (plf) 8 8 8 8 8 9 8 8 8 8 8 9 8 8 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 8 8 8 9 9 10 9 9 9 9 9 10 10 10 10 9 10 10 11 11 11 11 11 11 13 12 12 12 12 13 8 8 8 8 8 9 8 8 8 8 8 9 8 8 9 8 9 9 9 9 9 9 9 9 9 9 9 9 9 10 8 8 8 9 9 10 9 9 9 9 9 10 10 10 10 9 10 10 11 11 11 11 11 11 13 12 12 12 12 13 8 8 8 8 9 9 8 8 8 8 8 9 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 8 8 8 9 9 10 9 9 9 9 9 10 10 10 10 9 10 10 11 11 11 11 11 11 13 12 12 12 12 13 8 8 8 8 9 9 8 8 8 8 8 9 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 8 8 8 9 9 10 9 9 9 9 9 10 10 10 10 9 10 10 11 11 11 11 11 11 13 12 12 12 12 13 8 8 9 9 9 9 8 8 8 8 8 9 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 8 8 8 9 9 10 9 9 9 9 9 10 10 10 10 9 10 10 11 11 11 11 11 11 13 12 12 12 12 13 9 9 9 9 9 9 8 8 8 8 9 9 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 9 8 8 9 9 11 9 9 9 9 9 10 10 10 10 9 10 10 11 11 11 11 11 11 13 12 12 12 12 13 9 9 9 9 9 9 8 8 8 8 9 9 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 9 9 8 9 9 11 9 9 9 9 9 11 10 10 10 9 10 10 11 11 11 11 11 11 13 12 12 12 12 13 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 8 8 8 8 8 9 8 8 8 8 8 9 8 8 8 8 9 9 8 8 8 9 9 9 9 9 9 9 9 9 8 8 8 9 9 10 9 9 9 9 9 10 10 10 10 9 10 10 11 11 11 11 11 11 13 12 12 12 12 13 SP-Series Design Top Chord Radius ft 38 30 25 22 15 11 38 30 25 22 15 11 30 25 22 15 11 8 30 25 22 15 11 8 25 22 15 11 8 6 25 22 15 11 8 6 25 22 15 11 8 6 25 22 15 11 8 6 25 22 15 11 8 6 25 22 15 11 8 6 Special Profile Joists Center Depth in 20 20 20 20 20 20 24 24 24 24 24 24 28 28 28 28 28 28 32 32 32 32 32 32 38 38 38 38 38 38 44 44 44 44 44 44 50 50 50 50 50 50 58 58 58 58 58 58 66 66 66 66 66 66 76 76 76 76 76 76 Introduction Span ft 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 End Depth in 16 15 14 13 10 5 20 19 18 17 14 9 23 22 21 18 13 8 27 26 25 22 17 12 32 31 28 23 18 8 38 37 34 29 24 14 44 43 40 35 30 20 52 51 48 43 38 28 60 59 56 51 46 36 70 69 66 61 56 46 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 41 Introduction Bowstring Joist (SPBW) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 End Depth in 14 13 11 10 8 5 18 17 15 14 12 9 23 21 20 18 15 10 27 26 24 21 16 6 33 32 30 27 22 12 40 38 35 30 20 10 48 46 43 38 28 18 56 53 48 38 28 8 66 63 58 48 38 18 78 75 70 60 50 30 Center Depth in 20 20 20 20 20 20 24 24 24 24 24 24 30 30 30 30 30 30 36 36 36 36 36 36 42 42 42 42 42 42 50 50 50 50 50 50 58 58 58 58 58 58 68 68 68 68 68 68 78 78 78 78 78 78 90 90 90 90 90 90 Top Chord Radius ft 100 86 67 60 51 41 100 86 67 60 51 41 86 67 60 51 41 31 67 60 51 41 31 21 67 60 51 41 31 21 60 51 41 31 21 17 60 51 41 31 21 17 51 41 31 21 17 13 51 41 31 21 17 13 51 41 31 21 17 13 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 10 11 11 11 12 12 11 11 11 12 15 15 14 14 13 12 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 8 8 9 9 9 9 9 9 9 9 10 10 10 10 10 10 10 10 10 11 11 11 12 12 12 11 11 12 16 16 15 15 13 13 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 11 10 10 11 11 11 12 12 12 11 11 13 17 17 16 16 13 13 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 8 8 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 11 11 11 11 11 11 13 13 13 11 12 13 18 18 17 17 13 14 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 8 9 8 9 9 9 9 9 9 9 10 9 9 9 9 9 10 10 10 10 10 10 12 11 11 11 11 11 14 14 13 12 12 13 19 19 17 17 14 15 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 9 9 8 9 9 9 9 9 9 9 10 9 9 9 9 9 10 10 10 10 10 10 12 11 11 11 11 11 14 14 14 13 13 13 19 19 18 17 15 15 9 9 8 8 8 8 9 9 8 8 8 8 8 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 9 10 9 10 10 10 10 10 10 10 13 12 12 11 11 12 15 15 14 14 13 13 19 19 18 17 15 16 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 10 9 10 11 11 10 10 10 10 14 13 13 11 11 12 16 15 15 14 14 14 20 19 19 19 15 17 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 42 700 750 800 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 12 11 11 10 11 10 14 13 13 12 11 12 17 17 16 15 14 14 20 20 20 19 15 17 9 9 9 9 9 9 9 9 9 9 9 9 10 10 9 9 9 9 9 10 10 9 9 9 10 10 10 9 9 9 11 10 10 10 10 10 12 12 11 11 11 11 15 15 14 12 12 13 17 17 16 15 15 14 21 21 20 21 16 18 10 10 9 9 10 9 10 10 9 10 10 9 10 10 10 10 10 9 10 10 10 10 9 9 10 10 10 10 10 9 11 11 10 10 10 10 13 12 12 12 11 11 15 15 15 13 13 13 17 17 17 15 15 14 21 21 20 21 17 18 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Bowstring Joist (SPBW) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 16 16 16 16 16 16 13 13 13 13 13 13 12 12 12 12 12 12 12 12 13 12 12 12 13 13 13 13 13 13 14 14 14 13 13 13 16 14 14 14 14 14 18 18 18 16 15 16 21 21 21 19 18 16 25 24 23 21 20 20 17 19 18 18 18 18 14 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 12 14 14 14 13 13 13 15 14 14 14 14 13 17 16 15 15 15 14 19 18 18 17 15 16 21 21 21 20 18 17 26 24 23 22 22 20 19 19 19 19 19 19 15 15 15 15 15 15 14 14 14 13 14 13 13 13 13 13 13 13 14 14 14 14 14 13 15 15 14 14 14 14 17 16 16 15 15 15 20 19 19 18 16 16 22 22 22 20 19 17 26 25 23 22 22 20 Joist Self-Weight - Pounds per Linear Foot (plf) 9 9 9 9 9 9 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 8 8 8 9 9 9 9 9 9 10 10 10 9 10 9 11 11 11 10 11 10 13 12 12 12 12 12 17 16 16 14 13 14 21 21 19 18 16 18 10 10 10 10 10 10 9 9 9 9 9 9 9 9 8 8 8 8 9 9 9 9 9 8 9 9 9 9 9 9 10 10 10 10 10 9 11 11 11 11 11 10 14 13 13 12 12 12 18 17 17 15 13 14 22 21 20 19 17 19 11 11 12 12 12 12 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 10 9 9 11 11 11 10 10 10 11 11 11 11 11 11 15 14 14 12 12 12 18 18 17 16 14 14 22 21 20 19 17 19 13 13 13 13 13 13 10 10 10 10 10 10 10 10 10 10 10 9 10 10 10 9 9 9 11 10 10 10 10 10 11 11 11 11 10 10 12 12 11 12 11 11 15 15 14 13 12 13 18 18 19 16 14 14 22 22 20 19 17 19 13 13 13 13 14 14 11 11 11 11 11 11 10 10 10 10 10 10 10 10 10 10 10 10 11 11 11 10 10 10 12 11 12 11 11 11 13 13 12 12 12 12 16 16 15 14 13 13 19 19 19 18 15 15 23 23 21 19 18 19 14 14 14 14 14 14 12 12 12 12 13 13 11 11 11 11 11 11 11 11 11 11 11 10 12 11 11 11 11 11 12 12 12 12 12 11 14 13 13 13 12 12 17 16 16 14 13 14 20 20 20 18 16 15 24 24 22 19 19 19 15 15 15 16 16 16 13 13 13 13 13 13 12 11 11 11 11 11 12 12 12 11 11 11 12 12 12 12 12 12 13 12 12 13 13 12 15 14 13 13 13 13 18 18 17 15 14 14 21 21 20 19 16 16 24 24 23 20 19 19 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 9 9 9 10 10 10 9 9 9 11 10 10 10 10 10 12 12 12 12 11 12 16 15 15 14 13 13 20 20 18 16 16 17 SP-Series Design Top Chord Radius ft 225 193 150 123 104 91 193 150 123 104 91 72 150 123 104 91 72 62 123 104 91 72 62 46 123 104 91 72 62 46 104 91 72 62 46 32 91 72 62 46 32 25 91 72 62 46 32 25 91 72 62 46 32 25 72 62 46 32 25 19 Special Profile Joists Center Depth in 20 20 20 20 20 20 26 26 26 26 26 26 32 32 32 32 32 32 40 40 40 40 40 40 48 48 48 48 48 48 58 58 58 58 58 58 68 68 68 68 68 68 80 80 80 80 80 80 92 92 92 92 92 92 106 106 106 106 106 106 Introduction Span ft 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 End Depth in 14 13 11 9 7 5 19 17 15 13 11 7 23 21 19 17 13 10 29 27 25 21 18 10 37 35 33 29 26 18 45 43 39 36 28 13 53 49 46 38 23 8 65 61 58 50 35 20 77 73 70 62 47 32 87 84 76 61 46 16 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 43 Introduction Bowstring Joist (SPBW) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 End Depth in 19 17 14 12 9 7 20 18 15 13 10 5 26 23 21 18 13 8 31 29 26 21 16 6 41 39 36 31 26 16 49 46 41 36 26 6 61 58 53 48 38 18 70 65 60 50 30 10 84 79 74 64 44 24 100 95 90 80 60 40 Center Depth in 24 24 24 24 24 24 30 30 30 30 30 30 38 38 38 38 38 38 46 46 46 46 46 46 56 56 56 56 56 56 66 66 66 66 66 66 78 78 78 78 78 78 90 90 90 90 90 90 104 104 104 104 104 104 120 120 120 120 120 120 Top Chord Radius ft 480 343 240 201 161 142 240 201 161 142 121 97 201 161 142 121 97 81 161 142 121 97 81 62 161 142 121 97 81 62 142 121 97 81 62 43 142 121 97 81 62 43 121 97 81 62 43 33 121 97 81 62 43 33 121 97 81 62 43 33 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 11 11 11 11 11 11 9 9 9 9 9 10 9 9 9 9 8 8 9 9 9 9 9 9 10 10 10 10 9 9 11 11 10 10 10 10 12 12 12 12 11 11 15 13 13 13 13 13 20 19 19 16 16 16 25 25 25 23 21 19 13 13 13 13 13 13 10 10 10 10 11 11 10 9 9 9 9 10 10 10 9 9 9 9 11 11 11 10 10 10 11 11 11 11 11 10 14 13 12 13 12 12 16 14 14 13 13 13 21 20 20 17 16 16 26 26 26 24 22 19 14 14 14 14 14 14 12 13 13 13 13 12 11 11 10 10 10 10 10 10 10 10 10 10 12 11 11 11 11 10 12 12 12 12 12 11 14 14 13 13 13 13 17 15 15 14 14 14 22 21 20 18 17 17 27 26 26 25 23 20 16 16 16 16 16 16 13 13 13 13 13 14 11 11 11 11 11 11 12 12 11 11 11 11 12 12 12 12 12 11 13 13 13 13 13 12 16 15 14 14 14 13 18 16 17 15 14 15 22 21 21 19 17 17 27 28 27 25 23 21 17 17 17 17 18 18 15 15 15 15 14 14 13 12 12 13 13 13 13 13 12 12 12 13 13 13 13 14 13 12 13 13 13 13 13 13 16 16 15 15 14 15 19 18 17 16 15 15 23 22 22 20 18 19 28 29 28 26 23 22 19 19 19 19 19 19 16 16 16 16 16 16 14 14 14 14 14 13 14 14 13 13 13 13 14 14 14 14 14 13 14 14 14 15 15 14 17 17 16 15 15 15 20 19 18 16 16 16 24 23 22 21 19 19 29 29 29 27 23 24 20 20 21 21 21 21 17 17 17 17 17 17 15 15 15 15 15 15 14 14 14 14 14 14 14 14 15 14 15 14 15 15 15 15 15 15 19 19 17 16 15 16 20 19 19 17 17 16 25 25 23 22 19 19 31 30 29 28 24 24 22 22 23 23 24 23 18 18 18 18 19 19 16 16 15 16 15 15 15 15 15 15 14 14 15 15 15 15 15 15 16 15 15 15 16 16 19 19 17 17 16 17 21 20 20 18 17 18 25 25 25 22 23 21 32 31 30 29 25 24 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 44 700 750 800 25 25 25 25 25 25 20 20 20 20 20 20 17 17 17 17 17 17 15 15 16 16 16 15 16 16 16 16 15 16 16 15 16 16 17 16 19 19 19 17 17 18 21 20 20 21 19 20 25 25 25 22 23 21 32 32 31 29 27 24 25 25 26 26 26 26 21 21 21 21 21 21 17 17 17 17 18 17 17 17 16 16 17 17 16 16 16 16 16 17 17 17 16 17 17 17 20 20 19 18 18 18 23 21 20 21 20 20 27 26 25 23 23 22 32 32 32 30 27 25 27 27 27 27 28 28 21 21 21 21 21 22 19 19 19 19 19 19 17 17 17 17 17 17 18 18 18 16 16 17 18 17 17 17 18 17 21 20 20 20 19 19 24 22 21 21 21 20 28 27 26 24 23 23 33 34 32 30 27 26 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Bowstring Joist (SPBW) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 31 31 32 32 32 32 25 25 25 25 27 27 21 21 21 21 21 21 20 20 20 20 20 19 20 19 19 19 18 19 20 20 22 20 20 20 24 22 22 21 22 20 27 26 26 25 23 22 33 31 30 28 28 26 39 39 37 37 31 32 32 33 35 34 34 34 28 28 28 28 28 28 24 23 23 25 25 24 21 21 21 21 21 20 20 20 20 20 20 19 22 22 22 21 20 20 25 24 22 22 22 21 30 27 28 26 24 23 34 33 31 29 29 27 41 39 38 38 31 32 35 36 36 36 36 37 28 28 28 28 28 28 25 25 25 25 25 25 22 22 22 21 21 21 21 20 20 20 20 20 22 22 22 22 22 21 26 25 23 22 22 22 30 29 29 27 24 25 35 35 33 29 29 27 43 41 38 38 32 32 Joist Self-Weight - Pounds per Linear Foot (plf) 16 16 16 16 17 17 13 13 13 13 13 13 12 12 12 13 13 12 12 12 12 12 12 12 12 12 12 13 13 12 14 14 14 14 14 14 16 16 15 14 15 15 22 20 21 19 18 17 27 26 25 22 22 21 33 32 31 31 25 27 18 18 19 19 18 18 15 15 15 15 15 15 14 14 14 14 14 13 13 13 13 13 13 13 14 13 13 14 13 13 16 15 15 15 15 15 17 17 16 15 16 16 22 21 22 20 18 18 27 26 25 23 23 22 33 33 32 32 27 28 20 21 21 21 21 21 17 17 17 17 17 17 15 15 15 15 15 16 15 15 15 15 14 14 15 15 15 15 15 15 16 16 15 16 16 16 18 18 17 17 16 16 22 22 22 21 19 19 28 27 26 24 24 23 34 33 32 33 27 28 23 24 24 24 25 25 19 19 18 18 18 19 16 16 16 16 16 16 16 16 16 16 16 15 16 15 15 16 16 16 17 17 17 16 17 16 20 19 18 17 17 17 24 22 23 23 20 20 29 29 27 25 25 23 36 34 33 33 28 28 24 25 25 26 26 26 20 20 20 20 20 20 18 18 18 17 17 17 17 17 17 17 16 17 17 17 17 16 17 17 18 17 18 17 17 17 21 20 20 18 18 18 25 23 24 23 22 21 29 29 29 25 25 24 37 36 35 33 29 28 27 27 27 28 27 28 22 22 21 21 21 21 19 19 19 19 19 20 18 18 18 18 18 18 17 17 17 17 17 17 19 18 18 19 18 17 21 20 20 20 20 20 25 23 25 23 22 21 31 29 29 27 26 24 39 37 36 34 30 29 29 29 29 29 30 30 23 25 25 25 25 25 20 20 20 20 20 21 19 19 19 19 19 19 18 18 19 18 18 18 20 20 20 20 19 18 22 22 21 21 20 20 26 25 25 24 23 22 31 30 29 28 27 25 39 39 36 36 31 31 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 14 14 14 14 15 15 12 12 13 13 13 13 11 11 11 10 11 11 11 11 11 11 11 11 12 12 12 12 12 12 14 13 13 13 13 13 16 15 15 14 15 14 21 19 19 18 17 17 27 25 25 21 21 20 31 31 30 31 24 27 SP-Series Design Top Chord Radius ft 625 417 313 235 198 171 417 313 235 198 171 151 235 198 171 151 122 103 235 198 171 151 122 103 198 171 151 122 103 77 198 171 151 122 103 77 171 151 122 103 77 53 171 151 122 103 77 53 151 122 103 77 53 42 151 122 103 77 53 42 Special Profile Joists Center Depth in 28 28 28 28 28 28 36 36 36 36 36 36 44 44 44 44 44 44 54 54 54 54 54 54 64 64 64 64 64 64 76 76 76 76 76 76 90 90 90 90 90 90 104 104 104 104 104 104 120 120 120 120 120 120 136 136 136 136 136 136 Introduction Span ft 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 End Depth in 22 19 16 12 9 6 27 24 20 17 14 11 28 25 22 19 13 7 38 35 32 29 23 17 45 42 39 33 27 14 57 54 51 45 39 26 68 65 59 53 40 15 82 79 73 67 54 29 95 89 83 70 45 20 111 105 99 86 61 36 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 45 Introduction Bowstring Joist (SPBW) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 End Depth in 25 21 17 13 10 6 29 25 21 18 14 10 31 28 24 20 13 5 41 38 34 30 23 15 50 46 42 35 27 12 64 60 56 49 41 26 74 70 63 55 40 10 90 86 79 71 56 26 102 95 87 72 42 12 118 111 103 88 58 28 Center Depth in 32 32 32 32 32 32 40 40 40 40 40 40 50 50 50 50 50 50 60 60 60 60 60 60 72 72 72 72 72 72 86 86 86 86 86 86 100 100 100 100 100 100 116 116 116 116 116 116 132 132 132 132 132 132 148 148 148 148 148 148 Top Chord Radius ft 772 491 361 285 246 209 491 361 285 246 209 181 285 246 209 181 147 122 285 246 209 181 147 122 246 209 181 147 122 93 246 209 181 147 122 93 209 181 147 122 93 64 209 181 147 122 93 64 181 147 122 93 64 50 181 147 122 93 64 50 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 17 17 18 18 18 18 15 15 15 16 15 16 14 14 14 14 14 15 14 14 14 14 15 14 15 15 15 15 15 16 17 17 16 16 16 16 23 24 24 23 23 23 27 27 26 26 27 26 32 31 31 29 29 29 38 38 37 35 35 33 20 20 20 20 20 20 17 17 17 17 18 17 16 16 16 16 17 17 15 15 15 15 15 15 16 16 16 16 16 16 17 17 17 17 16 17 24 24 24 23 23 23 27 27 28 28 27 26 33 32 31 31 29 30 39 39 38 35 35 34 23 24 24 24 25 25 19 20 20 20 19 20 18 18 18 18 19 18 16 16 16 16 16 16 17 17 17 16 17 17 18 17 18 18 17 18 24 24 24 24 23 23 29 29 28 28 27 26 34 34 33 31 31 30 41 40 39 37 36 34 27 28 27 26 26 27 21 21 22 22 21 22 19 19 19 20 20 19 18 18 18 18 18 18 18 18 18 17 18 18 19 18 18 19 18 18 25 25 24 24 23 23 31 29 28 28 28 27 34 34 34 31 31 30 42 41 39 37 36 34 28 29 29 29 29 30 23 23 25 25 26 26 20 20 21 21 20 21 19 19 19 19 19 19 19 19 18 18 18 18 20 19 19 20 19 19 25 25 24 24 24 23 31 30 29 29 28 27 35 34 34 31 31 30 43 42 40 37 36 35 31 32 32 32 33 32 26 25 25 27 27 27 22 22 22 22 22 23 20 20 20 20 20 20 20 20 20 20 19 19 22 21 21 21 20 20 26 25 26 25 24 24 32 31 31 29 28 27 37 35 36 32 33 31 43 44 42 37 37 37 34 34 36 36 36 36 28 28 28 28 28 28 24 24 25 25 25 26 21 21 21 21 21 21 21 21 21 21 21 21 23 22 22 22 21 21 27 27 26 25 25 25 32 32 31 30 30 28 38 36 36 33 33 33 45 44 43 38 38 37 36 37 37 37 39 38 30 29 30 30 30 30 25 25 25 25 25 27 23 23 22 23 26 23 22 22 22 21 22 21 24 23 23 23 23 21 28 28 26 26 26 26 33 33 31 31 30 29 40 38 37 34 34 33 46 45 44 40 39 37 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 46 700 750 800 39 40 40 40 41 45 33 33 33 33 33 33 27 27 29 28 27 28 24 24 24 24 26 25 25 25 24 25 24 25 26 25 25 25 24 23 29 29 28 28 27 27 34 34 31 32 31 30 40 39 37 35 34 33 51 45 44 42 39 38 44 46 46 46 46 46 34 36 36 36 36 35 29 29 29 29 29 30 26 26 26 26 26 28 25 25 25 25 25 26 29 27 26 26 25 24 29 29 28 28 28 27 36 34 32 32 31 30 40 39 39 35 34 34 51 46 44 42 40 40 48 50 50 51 50 51 37 36 36 36 36 38 31 31 30 30 31 32 28 28 27 27 27 28 26 26 26 25 26 26 29 28 28 26 26 25 29 29 30 29 28 28 36 36 34 32 31 31 41 39 40 36 34 36 51 48 46 42 42 40 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Bowstring Joist (SPBW) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 50 50 50 50 50 53 37 37 37 36 39 38 32 32 32 32 32 32 30 30 30 29 29 29 29 28 28 28 27 28 30 30 30 28 28 29 33 32 32 32 30 31 38 37 37 34 34 33 42 43 42 40 37 36 53 47 48 43 41 40 54 54 54 54 55 58 40 40 40 40 40 40 34 34 33 33 35 34 32 31 31 31 31 30 30 30 30 30 29 28 31 32 33 31 29 29 35 33 33 32 32 32 38 39 37 35 34 33 44 44 42 40 38 38 53 47 48 45 41 41 58 58 58 58 58 61 42 42 42 47 46 47 36 35 36 36 37 38 33 33 32 32 32 32 33 32 32 31 31 30 34 34 33 33 32 30 37 35 34 35 32 33 40 39 38 37 35 34 44 46 44 43 39 38 54 52 48 45 43 43 Joist Self-Weight - Pounds per Linear Foot (plf) 25 25 26 27 26 26 21 21 21 21 21 21 20 20 21 22 21 21 21 21 21 21 21 21 22 22 22 22 21 21 24 23 23 23 24 23 28 27 27 25 26 25 31 30 30 30 29 28 36 35 35 34 34 30 41 39 41 38 36 34 29 29 29 29 29 29 22 22 22 24 22 23 21 21 22 22 21 22 21 21 21 21 21 21 22 22 22 22 22 22 25 24 24 24 24 23 28 27 27 27 26 26 32 33 31 30 29 28 36 36 36 34 34 32 43 40 41 39 37 35 32 32 32 33 31 31 26 26 28 28 28 27 22 22 22 22 22 23 22 22 21 21 21 23 23 23 23 23 23 22 25 25 25 25 24 24 29 29 28 27 27 27 33 33 32 30 31 30 36 38 36 36 34 32 45 42 42 39 37 37 36 36 36 36 36 36 28 28 28 28 28 30 24 25 25 25 25 25 23 23 22 23 22 23 24 24 23 23 23 23 26 26 25 25 24 24 30 29 28 28 27 29 33 33 33 31 31 31 39 38 38 36 34 33 46 44 43 40 39 37 39 39 39 39 39 43 30 30 30 30 30 32 25 25 25 25 27 27 24 24 24 24 25 26 25 25 24 25 24 25 27 26 26 26 26 25 30 30 29 29 28 30 35 34 34 32 31 31 39 41 38 36 35 35 46 44 43 40 39 38 46 46 46 46 46 49 33 33 33 33 33 33 28 28 28 25 28 29 25 25 25 26 26 26 26 26 26 25 26 25 29 28 28 27 27 26 31 31 30 30 29 30 35 36 34 33 32 32 40 41 39 38 36 35 47 44 43 40 39 40 50 50 50 50 50 53 34 35 35 35 35 35 30 29 29 29 29 31 28 27 27 27 27 27 27 27 26 26 27 28 29 28 28 28 28 27 32 32 31 30 30 30 36 36 34 33 34 32 41 41 40 39 37 35 49 46 43 41 40 40 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 21 21 22 22 22 22 20 20 19 20 20 20 20 20 20 22 21 21 21 21 21 21 21 21 22 21 21 21 21 21 24 23 23 23 23 23 27 26 26 25 25 25 31 30 30 29 28 28 36 35 34 34 32 30 41 39 40 38 35 34 SP-Series Design Top Chord Radius ft 817 566 433 335 284 238 566 433 335 284 238 211 335 284 238 211 169 144 335 284 238 211 169 144 284 238 211 169 144 108 284 238 211 169 144 108 238 211 169 144 108 74 238 211 169 144 108 74 238 211 169 144 108 74 211 169 144 108 74 58 Special Profile Joists Center Depth in 36 36 36 36 36 36 46 46 46 46 46 46 58 58 58 58 58 58 70 70 70 70 70 70 84 84 84 84 84 84 98 98 98 98 98 98 112 112 112 112 112 112 126 126 126 126 126 126 140 140 140 140 140 140 154 154 154 154 154 154 Introduction Span ft 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 End Depth in 27 23 19 14 10 5 33 29 24 20 15 11 36 32 27 23 14 6 48 44 39 35 26 18 58 53 49 40 32 14 72 67 63 54 46 28 81 77 68 60 42 7 95 91 82 74 56 21 109 105 96 88 70 35 119 110 102 84 49 14 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 47 Introduction Bowstring Joist (SPBW) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 End Depth in 30 25 20 15 10 5 35 30 25 20 15 10 42 37 32 27 22 12 51 46 41 36 26 16 60 55 50 40 30 10 74 69 64 54 44 24 88 83 78 68 58 38 97 92 82 72 52 12 111 106 96 86 66 26 125 120 110 100 80 40 Center Depth in 40 40 40 40 40 40 50 50 50 50 50 50 62 62 62 62 62 62 76 76 76 76 76 76 90 90 90 90 90 90 104 104 104 104 104 104 118 118 118 118 118 118 132 132 132 132 132 132 146 146 146 146 146 146 160 160 160 160 160 160 Top Chord Radius ft 960 641 481 385 321 276 641 481 385 321 276 242 481 385 321 276 242 194 385 321 276 242 194 163 321 276 242 194 163 123 321 276 242 194 163 123 321 276 242 194 163 123 276 242 194 163 123 85 276 242 194 163 123 85 276 242 194 163 123 85 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 26 26 27 26 26 26 21 22 21 22 22 21 20 20 21 21 22 21 21 21 21 21 23 22 22 22 22 22 22 23 25 25 25 24 24 24 29 28 28 27 27 26 33 32 31 30 30 28 37 36 36 36 34 32 42 42 42 39 39 37 30 30 30 31 31 31 24 26 26 26 26 26 21 21 21 21 23 22 22 22 22 22 23 23 23 22 22 23 23 23 26 25 25 25 24 24 30 29 29 28 27 27 33 33 33 32 30 30 39 38 37 36 36 33 42 44 43 41 42 37 34 34 35 34 34 34 26 28 29 29 28 28 23 23 23 23 25 25 23 23 23 23 24 24 24 23 24 24 23 23 26 26 26 25 25 25 30 29 30 29 28 28 34 34 33 32 31 32 40 39 38 37 36 35 44 44 44 41 42 37 39 39 39 42 42 42 30 30 30 32 30 32 26 26 28 26 28 27 25 24 24 26 26 26 26 25 25 24 24 26 27 27 26 26 26 27 31 31 30 30 29 29 35 35 36 33 33 32 42 39 39 38 36 35 46 47 45 42 42 41 45 44 45 45 47 48 33 32 33 35 35 35 28 28 28 28 28 28 26 28 26 26 26 28 26 26 26 26 27 27 30 29 28 28 27 27 32 32 32 31 30 30 36 35 36 35 33 32 43 40 39 38 39 36 47 47 46 44 42 41 50 50 50 49 49 49 36 36 36 36 38 38 30 29 29 30 29 32 28 28 28 28 28 29 28 27 28 27 28 28 30 29 29 29 28 28 33 32 32 32 31 31 38 37 36 35 34 34 44 41 40 38 39 37 47 49 48 45 42 42 50 50 50 50 53 53 38 38 40 39 41 42 33 32 32 32 32 32 31 30 30 30 30 29 30 29 29 30 30 31 31 31 30 29 30 30 34 34 33 32 31 31 39 37 36 35 36 35 45 43 41 40 39 37 48 50 48 47 43 43 58 58 58 58 58 58 42 41 42 42 41 42 36 35 37 37 36 38 33 33 33 33 32 34 32 32 31 31 30 31 33 33 33 32 30 30 36 35 35 35 33 33 40 40 38 37 36 36 47 44 43 41 40 39 50 52 48 47 45 43 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 48 700 750 800 62 62 62 62 64 65 47 51 51 51 51 54 38 38 38 38 38 39 35 35 35 35 35 36 34 34 34 33 33 32 35 35 34 34 33 33 38 37 36 37 35 33 42 40 40 39 38 37 48 45 46 43 42 40 54 54 50 47 46 45 65 65 65 66 65 65 51 51 51 51 51 54 41 41 41 41 41 45 36 36 36 36 36 37 36 36 35 36 35 36 37 37 36 35 35 34 39 39 39 38 38 36 43 43 41 41 40 37 49 47 46 44 43 41 54 54 52 49 47 46 70 70 70 70 70 73 51 51 51 51 51 54 42 42 46 43 46 47 39 39 39 38 38 40 38 37 37 36 35 36 38 38 38 37 36 36 41 39 40 40 39 38 43 43 43 41 41 40 51 49 47 46 45 41 54 54 53 51 49 46 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Bowstring Joist (SPBW) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 62 65 65 69 65 65 52 52 52 51 51 55 43 42 42 42 42 47 41 40 40 39 39 41 39 38 38 37 37 39 39 39 39 38 39 37 43 42 42 42 41 39 47 47 45 44 43 41 53 50 48 50 47 44 59 61 55 52 53 47 66 70 70 69 70 73 52 52 52 52 52 56 49 49 48 48 48 48 41 42 42 41 41 41 41 41 41 40 39 41 41 40 41 41 40 40 45 46 44 43 42 41 48 48 45 47 44 44 56 53 49 50 47 44 63 61 59 54 53 49 69 73 73 77 73 73 56 56 56 56 56 55 50 49 49 48 48 48 44 43 44 43 42 42 44 44 44 43 43 42 43 43 43 42 42 42 47 46 44 43 44 41 51 48 47 47 45 47 56 55 54 51 49 51 63 62 60 55 54 56 Joist Self-Weight - Pounds per Linear Foot (plf) 31 36 33 32 32 32 26 26 29 29 28 28 24 24 25 26 25 25 25 25 25 25 26 26 27 27 26 26 27 27 30 30 29 29 28 28 33 33 32 32 32 30 37 36 36 34 35 35 40 41 40 39 37 37 49 48 45 44 42 40 35 36 36 38 37 37 29 29 29 29 31 30 27 27 29 27 28 28 26 25 27 25 27 26 27 27 27 27 28 27 30 30 30 29 29 28 35 34 33 33 32 31 37 37 37 37 35 36 41 42 40 40 39 39 51 50 47 44 42 41 39 41 45 44 43 43 32 32 32 33 34 33 29 29 29 29 29 29 28 27 27 27 29 29 28 28 28 28 29 29 31 31 30 29 30 30 35 34 34 34 33 32 39 38 37 37 36 37 42 44 41 43 39 39 51 51 48 45 46 42 44 46 46 46 49 49 36 36 36 37 37 37 31 31 30 31 32 33 29 30 30 30 29 29 30 29 29 29 29 31 32 32 32 31 31 31 36 36 35 34 34 33 40 40 38 38 37 38 44 45 43 43 41 39 53 51 49 47 46 42 48 51 51 51 54 53 39 39 40 40 40 44 34 34 33 33 36 35 32 32 31 31 32 32 33 33 32 32 31 32 35 34 33 33 33 32 37 37 37 35 36 34 42 42 39 40 37 39 45 45 45 44 42 41 54 52 49 48 47 44 52 55 55 58 58 57 42 42 42 42 47 47 37 38 37 37 37 38 34 34 34 34 34 36 35 35 35 34 33 35 36 36 36 35 33 34 40 37 39 37 37 35 45 44 41 41 38 40 48 47 46 46 44 42 58 54 51 49 48 45 55 58 58 61 61 61 52 51 52 51 51 54 40 39 39 39 39 44 37 37 37 36 38 38 37 37 37 37 37 37 38 37 37 37 36 36 42 40 41 40 39 38 45 44 43 43 41 41 50 50 47 46 46 42 59 61 53 50 48 45 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 27 28 28 30 29 29 23 23 26 25 25 25 23 24 25 25 25 25 25 25 25 25 24 26 27 27 26 26 27 27 29 29 29 28 28 28 33 33 32 31 30 30 37 36 36 34 33 34 39 39 40 39 37 36 47 46 45 44 41 40 SP-Series Design Top Chord Radius ft 1105 715 553 435 359 313 715 553 435 359 313 272 553 435 359 313 272 219 435 359 313 272 219 184 359 313 272 219 184 139 359 313 272 219 184 139 359 313 272 219 184 139 313 272 219 184 139 96 313 272 219 184 139 96 313 272 219 184 139 96 Special Profile Joists Center Depth in 46 46 46 46 46 46 58 58 58 58 58 58 72 72 72 72 72 72 86 86 86 86 86 86 100 100 100 100 100 100 114 114 114 114 114 114 128 128 128 128 128 128 142 142 142 142 142 142 156 156 156 156 156 156 170 170 170 170 170 170 Introduction Span ft 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 End Depth in 35 29 24 18 12 7 41 36 30 24 19 13 50 44 38 33 27 16 58 52 47 41 30 19 66 61 55 44 33 10 80 75 69 58 47 24 94 89 83 72 61 38 103 97 86 75 52 7 117 111 100 89 66 21 131 125 114 103 80 35 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 49 Introduction Bowstring Joist (SPBW) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 End Depth in 38 31 25 19 13 6 43 37 31 25 18 12 51 45 39 32 26 14 59 53 46 40 28 15 73 67 60 54 42 29 81 74 68 56 43 18 95 88 82 70 57 32 109 102 96 84 71 46 116 110 98 85 60 10 130 124 112 99 74 24 Center Depth in 50 50 50 50 50 50 62 62 62 62 62 62 76 76 76 76 76 76 90 90 90 90 90 90 104 104 104 104 104 104 118 118 118 118 118 118 132 132 132 132 132 132 146 146 146 146 146 146 160 160 160 160 160 160 174 174 174 174 174 174 Top Chord Radius ft 1251 790 601 485 407 343 790 601 485 407 343 302 601 485 407 343 302 245 485 407 343 302 245 203 485 407 343 302 245 203 407 343 302 245 203 154 407 343 302 245 203 154 407 343 302 245 203 154 343 302 245 203 154 106 343 302 245 203 154 106 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 31 32 33 32 32 33 26 29 26 29 29 28 24 26 24 26 26 25 25 27 25 27 27 27 28 28 27 27 28 29 31 30 30 30 29 31 34 34 33 33 32 31 38 37 37 38 36 34 42 41 40 41 38 38 49 48 47 44 44 43 35 36 38 38 38 37 29 29 31 31 31 31 27 27 29 29 29 28 26 28 28 27 27 27 28 28 28 27 28 29 31 31 30 31 30 32 35 34 34 33 32 32 41 40 39 38 37 35 42 41 43 42 39 39 51 51 47 46 45 46 44 45 44 47 47 48 33 35 35 36 35 36 31 31 31 30 32 32 29 31 28 30 30 30 29 29 29 29 28 30 32 32 31 31 31 32 36 35 35 34 34 33 41 40 40 39 38 36 45 45 43 43 40 41 52 52 49 46 45 47 48 51 50 53 54 54 37 37 39 39 38 38 34 34 33 35 33 35 32 31 31 31 31 33 31 31 31 31 31 33 33 33 32 33 32 34 37 36 36 35 35 34 43 41 40 40 39 38 45 47 44 43 41 43 54 53 50 46 48 47 52 55 55 58 57 57 41 40 41 45 45 45 39 39 38 39 37 38 35 34 34 33 33 35 35 34 34 33 34 36 36 35 35 34 34 36 40 38 38 37 36 36 45 43 41 42 40 39 46 47 46 45 43 44 54 53 51 47 49 47 56 58 61 58 58 57 47 48 47 47 47 50 40 39 39 41 41 44 37 37 37 36 38 39 37 37 37 36 36 36 38 38 38 37 37 38 42 41 40 39 39 39 47 46 44 44 43 40 48 47 48 47 45 44 57 55 52 51 50 48 59 62 65 65 65 65 52 52 52 52 51 54 43 42 42 43 42 46 40 40 40 39 41 41 40 40 40 39 40 39 39 39 40 39 38 39 42 42 42 41 40 39 48 47 46 45 45 42 51 51 49 49 47 44 62 57 53 53 51 49 66 70 71 73 73 74 52 52 52 52 52 58 49 49 49 49 48 52 43 43 43 42 47 47 42 40 41 41 40 40 42 42 41 41 41 42 45 44 43 43 42 41 50 48 49 47 45 44 53 51 50 53 48 46 62 62 55 53 53 55 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 50 700 750 800 70 73 73 74 73 74 60 60 59 59 60 62 54 53 53 53 53 56 45 48 48 44 48 51 45 44 44 44 43 43 45 44 44 43 44 47 48 46 45 44 45 44 50 50 49 50 48 46 56 54 51 53 50 50 63 63 62 54 54 55 78 83 83 83 85 86 60 60 60 59 60 66 54 54 54 53 53 57 50 51 51 50 48 53 50 46 49 46 48 48 47 47 46 45 45 47 48 49 49 47 45 45 56 55 50 54 50 51 59 57 56 54 51 52 65 64 62 61 55 55 87 89 93 91 93 97 64 64 63 63 66 66 58 58 57 57 57 57 51 51 51 50 50 54 50 50 49 49 51 50 52 51 51 50 50 49 55 52 52 50 51 50 57 55 55 56 55 51 59 59 58 57 56 54 67 66 64 62 62 56 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Bowstring Joist (SPBW) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 79 79 79 78 86 86 65 64 64 67 67 66 58 58 57 57 61 60 55 55 55 55 54 58 51 51 51 51 50 54 51 51 51 51 50 53 53 52 52 52 51 50 55 54 54 53 53 51 58 58 57 56 54 52 60 59 59 59 59 55 83 83 83 83 90 90 68 68 68 71 71 70 63 62 61 61 61 65 56 56 56 55 59 61 53 53 53 52 52 56 54 53 53 52 52 55 53 53 53 52 52 51 56 56 55 55 54 53 60 59 59 56 56 54 62 64 63 60 59 58 93 94 92 92 102 102 72 72 72 76 75 75 65 66 65 65 65 68 59 59 60 59 59 62 58 58 58 58 60 59 54 54 54 53 52 55 54 54 55 54 53 57 58 57 56 55 55 53 61 60 59 59 58 56 66 64 64 61 60 58 Joist Self-Weight - Pounds per Linear Foot (plf) 39 39 44 44 44 43 32 32 32 34 34 34 31 31 33 33 32 32 30 32 31 33 32 32 32 31 31 33 32 32 34 33 33 32 34 35 36 36 35 35 37 37 39 38 38 38 39 39 44 44 43 41 42 40 46 47 46 46 44 43 46 46 46 49 49 49 38 38 40 39 39 39 34 36 34 35 36 35 32 32 34 34 34 34 33 33 33 33 34 34 36 35 35 34 36 36 38 37 37 37 39 37 40 40 40 40 39 41 48 45 44 42 43 42 48 49 47 46 46 44 51 51 54 54 54 54 41 41 41 46 45 45 38 38 40 40 40 39 36 35 36 38 37 37 35 35 35 34 36 37 37 36 36 36 37 38 39 39 39 38 39 40 42 41 42 41 40 42 48 46 45 44 45 43 49 51 48 49 48 47 55 55 58 58 58 58 48 48 47 47 51 50 42 41 42 41 46 45 39 39 39 42 41 40 39 39 38 40 39 41 39 38 38 37 39 39 41 40 41 39 39 40 44 43 43 43 42 43 48 47 47 47 46 45 52 51 51 49 48 47 63 62 62 65 65 65 52 52 52 52 55 55 49 49 49 47 52 51 42 43 42 48 47 46 41 41 40 40 42 41 41 40 40 40 42 41 42 42 41 41 40 42 45 44 44 44 43 45 51 50 48 47 46 45 53 51 51 51 50 49 66 66 66 69 69 68 56 56 56 56 59 59 49 49 49 53 53 56 48 45 48 48 51 51 44 43 43 43 43 42 44 43 43 43 42 47 45 44 44 44 43 48 47 47 46 44 46 46 51 50 51 49 48 46 56 55 52 51 51 49 73 74 74 74 73 73 60 60 60 60 63 62 55 54 54 53 53 57 51 51 50 50 54 52 49 49 49 49 48 52 47 46 46 46 48 51 49 48 47 45 46 50 50 50 48 47 47 46 54 53 51 51 50 48 59 57 57 53 56 53 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 34 34 34 35 35 36 30 29 31 31 31 30 28 30 28 30 30 29 28 30 30 30 30 31 30 31 31 31 31 32 32 32 32 32 32 32 35 35 34 35 33 36 39 38 37 37 39 39 42 42 41 40 40 40 46 46 46 44 43 42 SP-Series Design Top Chord Radius ft 1297 865 673 535 444 380 865 673 535 444 380 332 673 535 444 380 332 266 535 444 380 332 266 225 535 444 380 332 266 225 444 380 332 266 225 170 444 380 332 266 225 170 444 380 332 266 225 170 444 380 332 266 225 170 444 380 332 266 225 170 Special Profile Joists Center Depth in 56 56 56 56 56 56 68 68 68 68 68 68 80 80 80 80 80 80 92 92 92 92 92 92 104 104 104 104 104 104 116 116 116 116 116 116 128 128 128 128 128 128 140 140 140 140 140 140 152 152 152 152 152 152 164 164 164 164 164 164 Introduction Span ft 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 End Depth in 42 35 29 22 15 8 47 41 34 27 20 13 53 46 39 32 25 11 58 51 44 37 23 10 70 63 56 49 35 22 75 68 61 47 34 6 87 80 73 59 46 18 99 92 85 71 58 30 111 104 97 83 70 42 123 116 109 95 82 54 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 51 SP-Series Tables SP-Series Design Special Profile Joists Introduction Bowstring Joist (SPBW) Tables Span End Depth Center Depth Top Chord Radius 300 350 400 450 500 550 600 650 700 750 800 ft 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 in 45.0 37.5 30.0 22.5 15.0 7.5 49.5 42.0 34.5 27.0 19.5 12.0 54.0 46.5 39.0 31.5 24.0 9.0 58.5 51.0 43.5 36.0 21.0 6.0 70.5 63.0 55.5 48.0 33.0 18.0 82.5 75.0 67.5 60.0 45.0 30.0 87.0 79.5 72.0 57.0 42.0 12.0 99.0 91.5 84.0 69.0 54.0 24.0 111.0 103.5 96.0 81.0 66.0 36.0 123.0 115.5 108.0 93.0 78.0 48.0 in 60 60 60 60 60 60 72 72 72 72 72 72 84 84 84 84 84 84 96 96 96 96 96 96 108 108 108 108 108 108 120 120 120 120 120 120 132 132 132 132 132 132 144 144 144 144 144 144 156 156 156 156 156 156 168 168 168 168 168 168 ft 1441 983 721 585 482 418 983 721 585 482 418 363 721 585 482 418 363 291 585 482 418 363 291 244 585 482 418 363 291 244 585 482 418 363 291 244 482 418 363 291 244 185 482 418 363 291 244 185 482 418 363 291 244 185 482 418 363 291 244 185 plf 38 38 38 38 38 42 33 33 32 34 34 34 30 30 32 32 31 31 32 32 32 33 33 32 32 32 34 34 33 34 34 34 36 35 35 36 37 36 38 38 37 37 40 41 40 42 39 40 43 43 42 43 43 44 46 48 47 45 44 44 plf 47 47 46 49 49 49 37 37 39 38 38 38 36 34 36 36 36 36 33 35 33 35 35 36 34 36 34 35 35 34 35 36 36 35 37 37 39 39 38 39 37 39 43 42 41 42 40 41 45 44 43 43 44 44 48 50 48 46 46 47 plf 51 51 54 54 54 54 41 41 46 46 45 49 38 40 40 40 39 43 37 39 39 38 38 43 37 37 36 38 38 39 38 38 37 37 37 38 40 40 39 39 39 42 44 43 43 43 43 43 46 47 46 45 45 45 50 50 50 49 49 47 plf 59 59 59 58 58 58 48 48 51 51 51 50 43 42 48 48 47 52 40 41 39 42 41 44 40 40 42 41 39 41 40 40 40 39 41 40 44 41 41 42 39 42 47 47 44 44 43 43 49 48 48 46 47 45 51 50 51 50 49 49 plf 63 63 63 65 65 65 53 52 52 56 55 55 49 49 49 52 52 52 43 43 43 48 50 49 43 42 42 42 48 47 42 43 43 42 42 44 44 43 43 43 42 43 47 47 46 46 45 45 49 48 48 48 47 48 62 53 52 50 49 49 plf 71 71 74 74 74 74 57 56 60 59 59 59 54 54 54 53 57 56 49 49 48 48 50 51 46 46 45 45 48 51 47 47 46 46 45 50 47 47 46 46 45 49 50 49 48 47 47 51 51 50 51 49 49 52 62 54 53 52 50 54 plf 76 76 75 76 82 82 61 61 60 64 64 66 55 55 58 57 58 60 51 51 51 50 50 53 51 51 51 50 50 53 51 51 51 51 51 52 50 50 49 48 52 53 52 52 52 49 53 53 54 54 54 53 52 52 62 61 60 55 59 54 plf 83 83 83 86 85 86 65 65 71 71 70 70 59 59 58 62 58 64 56 55 56 55 62 61 53 53 53 52 52 56 54 53 53 53 52 52 53 53 52 53 52 53 57 57 56 55 54 53 58 57 56 57 55 55 62 62 62 61 59 56 plf 94 94 91 93 101 102 72 72 71 76 75 75 63 63 66 69 69 67 59 60 59 59 63 64 59 59 58 58 57 63 56 55 55 55 54 54 55 55 54 54 54 53 58 57 56 57 55 54 61 60 59 58 56 56 64 63 64 62 59 57 plf 100 100 102 102 101 102 76 81 80 80 79 86 66 66 66 73 69 72 60 60 60 60 66 65 62 61 61 61 61 64 57 56 57 57 56 57 57 57 57 56 55 60 60 59 59 58 57 60 62 61 61 58 59 57 65 66 66 62 61 61 plf 101 100 111 110 109 109 80 81 80 80 85 87 73 73 73 73 77 76 67 67 67 71 71 73 63 63 62 62 61 64 64 64 64 64 63 63 63 62 61 61 61 60 62 62 63 61 62 60 64 63 61 62 60 62 69 69 68 64 62 62 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 52 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Bowstring Joist (SPBW) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 89 94 93 102 102 102 78 81 81 80 87 87 70 70 74 70 76 76 65 67 68 68 72 70 63 63 62 62 61 66 65 65 64 64 64 63 63 60 62 61 60 64 63 64 62 60 62 63 64 63 64 63 62 66 72 71 67 64 64 65 97 101 111 111 110 110 81 81 81 80 87 87 74 74 79 79 78 77 69 68 68 68 72 71 67 64 65 71 70 68 66 65 64 65 64 71 68 68 67 66 67 71 68 67 66 65 64 63 69 68 67 67 66 67 73 71 72 69 67 68 108 113 113 112 114 122 86 86 86 94 94 103 77 82 82 82 81 88 76 75 74 74 75 78 71 71 70 72 74 73 69 69 68 68 73 72 69 69 68 70 69 72 69 68 67 66 65 72 71 70 69 67 67 72 77 76 73 71 70 71 Joist Self-Weight - Pounds per Linear Foot (plf) 45 47 47 50 49 50 39 40 40 45 44 44 39 41 38 40 40 43 37 38 37 39 39 38 37 36 38 37 37 38 39 38 38 40 39 39 41 40 42 40 41 46 45 44 44 45 44 44 48 48 48 46 45 49 54 53 51 50 50 51 53 56 55 58 58 58 48 48 52 51 51 51 48 41 47 46 46 52 41 41 43 40 42 42 40 40 44 43 42 46 41 41 40 43 42 47 43 43 42 41 43 46 46 45 46 45 45 46 49 49 48 46 47 49 55 54 52 51 50 53 60 59 63 62 62 66 53 53 57 56 56 55 50 49 49 53 52 52 44 45 44 49 49 50 44 43 50 44 49 48 45 44 43 44 45 49 45 45 45 44 45 48 48 47 47 47 45 51 51 50 50 49 49 52 56 55 53 53 51 53 64 66 66 66 66 70 58 57 60 60 60 59 54 54 54 58 57 60 50 50 49 49 54 52 47 47 50 49 53 52 48 47 47 47 52 51 49 47 48 47 47 54 50 50 50 49 48 54 53 53 53 50 50 52 59 58 54 55 53 56 71 74 75 74 74 74 62 65 65 65 67 67 58 58 58 61 61 60 57 56 56 56 55 59 52 52 52 51 53 54 52 53 52 52 53 51 54 50 53 53 53 54 54 55 53 53 52 54 59 59 55 55 54 55 65 65 57 60 58 56 76 79 79 87 86 85 65 69 69 68 67 67 59 58 63 62 62 64 57 57 60 60 60 62 54 55 54 54 53 57 55 54 54 54 53 53 56 56 55 54 53 57 58 57 56 57 56 54 61 60 59 57 55 55 66 65 64 62 60 60 80 84 84 91 91 90 72 72 77 76 75 75 66 66 66 70 69 72 61 61 61 60 65 64 62 60 62 61 61 64 57 57 56 57 56 62 57 57 57 56 57 61 60 60 59 58 57 56 62 61 60 61 59 60 67 68 66 64 61 62 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 43 40 45 44 44 48 36 38 38 38 37 38 33 35 33 34 34 36 33 35 32 34 34 34 34 36 37 36 35 35 36 38 38 36 39 38 41 39 40 40 41 40 43 42 42 42 44 42 45 45 46 46 44 46 54 52 50 49 50 49 SP-Series Design Top Chord Radius ft 1585 1057 794 620 519 447 1057 794 620 519 447 393 794 620 519 447 393 316 794 620 519 447 393 316 620 519 447 393 316 265 620 519 447 393 316 265 519 447 393 316 265 200 519 447 393 316 265 200 519 447 393 316 265 200 519 447 393 316 265 200 Special Profile Joists Center Depth in 66 66 66 66 66 66 78 78 78 78 78 78 90 90 90 90 90 90 102 102 102 102 102 102 114 114 114 114 114 114 126 126 126 126 126 126 138 138 138 138 138 138 150 150 150 150 150 150 162 162 162 162 162 162 174 174 174 174 174 174 Introduction Span ft 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 End Depth in 50 42 34 25 17 9 54 46 37 29 21 13 58 49 41 33 25 9 70 61 53 45 37 21 73 65 57 49 33 17 85 77 69 61 45 29 89 81 73 57 41 8 101 93 85 69 53 20 113 105 97 81 65 32 125 117 109 93 77 44 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 53 Introduction Bowstring Joist (SPBW) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 End Depth in 53 44 35 26 18 9 56 47 38 30 21 12 68 59 50 42 33 24 71 62 54 45 36 19 74 66 57 48 31 13 86 78 69 60 43 25 98 90 81 72 55 37 102 93 84 67 49 14 114 105 96 79 61 26 126 117 108 91 73 38 Center Depth in 70 70 70 70 70 70 82 82 82 82 82 82 94 94 94 94 94 94 106 106 106 106 106 106 118 118 118 118 118 118 130 130 130 130 130 130 142 142 142 142 142 142 154 154 154 154 154 154 166 166 166 166 166 166 178 178 178 178 178 178 Top Chord Radius ft 1730 1132 841 670 568 485 1132 841 670 568 485 423 1132 841 670 568 485 423 841 670 568 485 423 342 670 568 485 423 342 284 670 568 485 423 342 284 670 568 485 423 342 284 568 485 423 342 284 216 568 485 423 342 284 216 568 485 423 342 284 216 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 45 47 46 50 50 50 39 38 41 41 40 44 36 39 38 38 37 37 36 38 35 37 37 36 36 36 39 36 37 36 39 38 41 41 40 38 42 42 43 44 43 42 45 47 44 44 45 44 49 48 49 47 49 53 54 52 52 52 50 54 53 52 55 55 55 58 48 48 52 51 51 51 41 43 42 47 46 46 41 44 44 43 42 41 41 40 43 44 47 46 42 41 44 44 44 43 44 44 43 46 45 45 48 47 46 47 48 45 50 50 49 48 49 54 56 54 54 52 53 54 57 59 59 59 58 66 53 53 57 56 56 56 50 48 48 53 53 52 46 44 50 49 49 52 46 50 44 50 49 48 45 47 44 44 46 49 46 47 47 46 47 47 48 48 47 47 49 50 51 51 50 49 49 54 57 54 55 54 53 59 64 67 67 66 66 70 58 57 60 60 60 59 55 55 54 59 58 57 50 50 50 54 53 52 47 50 50 54 53 54 48 48 48 53 51 54 49 50 49 49 53 53 51 51 50 50 54 56 54 53 52 52 55 57 60 58 57 56 55 60 71 74 75 75 74 74 62 66 61 65 67 67 59 59 59 62 62 61 57 57 61 56 60 59 52 52 52 57 56 54 53 53 52 55 52 55 55 54 55 55 53 57 54 55 54 55 54 56 57 60 59 58 56 57 64 62 65 61 59 64 76 80 87 86 86 85 69 73 73 72 71 75 63 64 63 67 66 65 60 61 61 65 64 62 59 59 59 58 63 65 56 55 54 57 54 58 57 57 56 56 55 59 58 59 58 56 61 58 62 62 61 60 58 57 67 66 65 63 61 65 88 93 102 103 102 102 72 78 77 76 76 75 66 66 71 71 70 69 62 61 61 66 65 66 62 62 63 62 66 65 59 58 57 57 64 63 60 59 58 58 62 61 61 60 59 59 62 65 64 63 62 60 63 65 69 68 66 67 64 65 96 101 103 103 102 102 80 81 81 88 88 87 74 73 80 73 77 77 68 68 71 68 72 71 64 64 63 71 70 68 66 65 65 65 68 68 64 64 64 64 62 62 64 65 62 63 62 65 66 67 67 65 63 68 72 72 71 69 69 70 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 54 700 750 800 97 101 111 111 110 110 85 85 86 94 92 92 75 74 80 80 79 78 70 70 71 77 76 75 71 71 70 73 74 73 67 66 69 68 68 71 70 69 69 68 70 70 68 67 67 66 72 70 70 70 69 67 68 73 74 73 73 72 69 70 108 113 113 123 122 122 94 94 104 105 104 103 83 83 82 82 90 89 77 76 76 79 80 79 72 74 73 73 78 76 70 70 70 69 73 71 73 72 73 72 70 70 73 75 72 74 72 75 72 74 73 72 70 77 79 79 78 75 74 75 117 124 124 133 133 132 102 113 113 112 112 111 88 87 87 87 95 95 78 77 80 79 80 87 78 78 77 77 83 81 77 75 76 76 75 80 74 74 73 74 74 77 76 75 75 74 75 79 79 79 78 76 78 77 83 79 78 79 77 75 Joist Self-Weight - Pounds per Linear Foot (plf) Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 9 rows 10 rows Bowstring Joist (SPBW) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 114 114 113 123 122 122 95 94 105 105 103 103 83 83 92 82 91 89 84 80 84 83 91 90 77 77 77 83 76 81 76 76 75 82 80 77 76 75 74 74 75 79 74 73 72 73 77 78 75 76 75 74 76 78 78 77 76 76 79 80 124 124 124 123 123 122 103 115 113 113 112 123 96 96 107 106 105 105 84 84 84 93 92 90 79 78 85 86 81 88 80 80 79 83 83 82 78 78 77 77 76 81 80 78 78 78 78 84 77 76 75 76 76 79 80 79 78 79 79 82 124 124 124 124 133 133 115 115 114 114 124 123 103 103 115 114 114 113 90 90 91 107 107 106 86 86 86 86 85 93 81 81 84 83 83 90 79 78 83 82 81 85 81 81 80 79 85 84 83 83 82 81 80 79 83 82 81 79 82 83 Joist Self-Weight - Pounds per Linear Foot (plf) 57 56 56 59 59 58 54 53 57 56 56 56 49 48 52 51 51 51 44 44 49 49 48 53 44 47 43 43 49 47 44 47 46 46 49 47 46 49 48 48 52 49 47 49 47 49 53 51 47 48 47 50 49 53 50 52 49 51 56 53 61 60 64 64 66 66 55 57 61 60 60 60 55 55 58 59 58 57 51 56 51 55 54 53 51 52 51 50 54 53 54 48 51 55 57 55 51 49 49 54 53 56 51 50 55 54 54 58 51 50 57 50 55 56 54 53 52 52 58 60 68 69 72 72 74 74 62 66 61 65 67 67 59 59 58 62 62 61 57 61 60 61 60 62 53 53 53 58 58 56 54 53 59 55 57 55 55 54 58 55 57 56 55 56 55 54 60 58 56 55 57 57 55 60 57 60 59 59 58 62 75 75 75 79 79 86 69 66 73 72 75 75 63 67 63 70 69 68 61 65 60 65 64 62 59 61 59 61 66 64 56 56 61 55 59 66 56 56 58 55 60 59 59 58 57 56 61 61 60 59 58 58 57 61 63 61 60 59 64 62 84 84 88 87 87 86 73 72 77 76 76 84 66 67 71 70 70 73 65 69 72 71 71 70 63 62 62 67 67 65 64 64 63 69 68 66 60 59 61 66 60 64 62 61 62 61 61 66 62 62 61 60 60 61 63 62 62 61 64 69 93 93 104 103 103 103 81 81 89 89 88 87 75 80 80 79 77 77 69 69 73 73 75 74 70 70 75 74 74 72 65 65 73 71 71 69 67 67 66 70 70 71 70 69 68 68 67 72 67 67 65 66 64 69 67 68 65 68 64 71 101 101 112 111 111 110 86 86 94 94 103 103 82 82 82 82 89 88 76 76 82 80 80 79 71 73 77 79 76 76 72 72 75 71 75 77 71 70 73 70 74 72 70 71 72 71 76 75 73 72 71 70 73 77 70 69 70 68 75 73 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables 48 48 47 51 50 50 42 48 42 47 49 49 40 42 39 41 41 44 40 39 42 41 40 39 40 40 42 42 41 45 43 40 43 42 43 41 42 41 44 44 43 43 44 45 47 46 47 45 46 45 44 47 48 48 49 47 46 50 51 53 SP-Series Design Top Chord Radius ft 1777 1207 914 720 605 514 1207 914 720 605 514 453 1207 914 720 605 514 453 914 720 605 514 453 363 914 720 605 514 453 363 720 605 514 453 363 306 720 605 514 453 363 306 720 605 514 453 363 306 720 605 514 453 363 306 605 514 453 363 306 231 Special Profile Joists Center Depth in 76 76 76 76 76 76 86 86 86 86 86 86 96 96 96 96 96 96 106 106 106 106 106 106 116 116 116 116 116 116 126 126 126 126 126 126 136 136 136 136 136 136 146 146 146 146 146 146 156 156 156 156 156 156 166 166 166 166 166 166 Introduction Span ft 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 End Depth in 57 48 39 29 20 10 58 49 39 30 20 11 68 59 49 40 30 21 69 59 50 40 31 12 79 69 60 50 41 22 79 70 60 51 32 14 89 80 70 61 42 24 99 90 80 71 52 34 109 100 90 81 62 44 110 100 91 72 54 16 10 rows Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification Bearing line have have aa seat seat depth depth as indicated in the chart below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line indicated in the chart below Minimum 5" 7½" 10" Maximum 12½" 55 Introduction Scissor Joist (SPSC) Tables The following weight tables are representative of SP-Series design or constructability by NMBS. The SP-Series Scissor joist designs for Scissor Joists with parameters shown in the joists in the following tables are designed assuming pinneddiagram below. The maximum allowable Live Load deflection roller supports. If this design results in a predicted approximate is L/240 for a Live Load equal to 75 percent of the Total Load horizontal deflection, бx, greater than two inches at the roller listed in the table. The tables also give bridging requirements support, the approximate weight(SPSC) is flagged with the notation, SCISSOR JOIST TABLES per Section 904.5(d), the required seat depth for the given бx>2. The specifying professional should do further investigation The following weight tables are representative of SP-Series joist designs for Scissor Joists with parameters shown in the profile, as well as the estimated self-weight in pounds per into the actual horizontal deflection and consider alternatives diagram below. The maximum allowable deflection for the joist is L/240 for a Live Load equal to 75 percent of the Total linear foot. catalog twoalso design examplesrequirements for as explained in HORIZONTAL page Load listedThis in the table. provides The tables give bridging per Section 904.5(d), the REACTIONS required seaton depth for 14. the reference and clarification on design issues. The following For further information, please contact your nearest NMBS given profile, as well as the estimated pounds per linear foot. This catalog provides two complete design examples for reference and representative clarification onofdesign issues. The following are not or representative of any limits or constraints on tables are not any limits or constraints on tables representative visit www.newmill.com. Special Profile Joists design or constructability per NMBS. For further information, please contact your nearest NMBS representative or visit www.newmill.com. ALL TABLES ARE BASED ON ASD SP-Series Design ALL TABLES ARE BASED ON ASD Standard Specification SP-Series Tables SCISSOR JOIST (SPSC) 56 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 52 Scissor Joist (SPSC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 7 7 7 7 9 10 7 7 7 7 7 8 7 7 7 7 7 10 7 7 7 7 7 9 7 7 7 7 8 8 7 7 7 7 7 8 7 7 7 7 7 9 8 8 8 8 9 11 8 8 8 8 9 12 8 8 8 9 10 13 7 7 7 7 9 10 7 7 7 7 7 8 7 7 7 7 7 10 7 7 7 7 7 9 7 7 7 7 8 9 7 7 7 7 7 9 7 7 7 7 7 9 8 8 8 8 9 12 8 8 8 9 9 12 8 8 9 9 10 13 7 7 7 7 9 10 7 7 7 7 8 8 7 7 7 7 7 10 7 7 7 7 8 10 7 7 7 7 8 9 7 7 7 7 7 9 7 7 7 7 8 10 8 8 8 8 10 12 9 9 9 9 10 12 9 9 9 9 10 14 Joist Self-Weight - Pounds per Linear Foot (plf) 7 7 7 7 8 10 7 7 7 7 7 8 7 7 7 7 7 9 7 7 7 7 7 8 7 7 7 7 8 8 7 7 7 7 7 8 7 7 7 7 7 8 7 7 6 7 7 8 7 7 7 7 7 9 7 7 7 7 8 10 7 7 7 7 8 10 7 7 7 7 7 8 7 7 7 7 7 9 7 7 7 7 7 8 7 7 7 7 8 8 7 7 7 7 7 8 7 7 7 7 7 8 7 7 7 7 7 8 7 7 7 7 7 9 7 7 7 7 8 10 7 7 7 7 8 10 7 7 7 7 7 8 7 7 7 7 7 9 7 7 7 7 7 8 7 7 7 7 8 8 7 7 7 7 7 8 7 7 7 7 7 8 7 7 7 7 7 9 7 7 7 7 7 9 7 7 7 7 8 10 7 7 7 7 8 10 7 7 7 7 7 8 7 7 7 7 7 9 7 7 7 7 7 8 7 7 7 7 8 8 7 7 7 7 7 8 7 7 7 7 7 8 7 7 7 7 7 9 7 7 7 7 8 10 7 7 7 7 8 11 7 7 7 7 8 10 7 7 7 7 7 8 7 7 7 7 7 9 7 7 7 7 7 8 7 7 7 7 8 8 7 7 7 7 7 8 7 7 7 7 7 8 7 7 7 7 8 10 7 7 7 7 8 10 7 7 7 8 9 11 7 7 7 7 8 10 7 7 7 7 7 8 7 7 7 7 7 9 7 7 7 7 7 8 7 7 7 7 8 8 7 7 7 7 7 8 7 7 7 7 7 8 7 7 7 7 8 10 7 7 8 8 8 11 8 8 8 8 9 12 7 7 7 7 8 10 7 7 7 7 7 8 7 7 7 7 7 9 7 7 7 7 7 9 7 7 7 7 8 8 7 7 7 7 7 8 7 7 7 7 7 9 7 7 7 8 8 11 8 8 8 8 8 11 8 8 8 8 9 12 7 7 7 7 8 10 7 7 7 7 7 8 7 7 7 7 7 10 7 7 7 7 7 9 7 7 7 7 8 8 7 7 7 7 7 8 7 7 7 7 7 9 8 8 8 8 9 11 8 8 8 8 9 12 8 8 8 8 10 13 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables Shape Depth in 13 14 15 18 25 41 17 18 19 22 29 46 21 22 23 26 34 50 25 26 27 30 38 55 29 30 31 34 42 59 33 34 35 38 46 64 37 38 39 42 50 68 41 42 43 46 54 72 45 46 47 50 58 77 49 50 51 54 62 81 SP-Series Design Top Chord Pitch in/ft 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 Special Profile Joists Ridge Depth in 10.0 10.0 10.0 10.1 10.3 11.2 14.0 14.0 14.0 14.1 14.4 15.7 18.0 18.0 18.1 18.1 18.6 20.1 22.0 22.0 22.1 22.2 22.7 24.6 26.0 26.1 26.1 26.2 26.8 29.1 30.0 30.1 30.1 30.2 30.9 33.5 34.0 34.1 34.1 34.3 35.0 38.0 38.0 38.1 38.1 38.3 39.2 42.5 42.0 42.1 42.1 42.3 43.3 47.0 46.0 46.1 46.2 46.4 47.4 51.4 Introduction Span ft 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Chord Depth in 10 10 10 10 10 10 14 14 14 14 14 14 18 18 18 18 18 18 22 22 22 22 22 22 26 26 26 26 26 26 30 30 30 30 30 30 34 34 34 34 34 34 38 38 38 38 38 38 42 42 42 42 42 42 46 46 46 46 46 46 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 57 Introduction Scissor Joist (SPSC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Chord Depth in 10 10 10 10 10 10 14 14 14 14 14 14 18 18 18 18 18 18 22 22 22 22 22 22 26 26 26 26 26 26 30 30 30 30 30 30 34 34 34 34 34 34 38 38 38 38 38 38 42 42 42 42 42 42 46 46 46 46 46 46 Ridge Depth in 10.0 10.0 10.0 10.1 10.3 11.2 14.0 14.0 14.0 14.1 14.4 15.7 18.0 18.0 18.1 18.1 18.6 20.1 22.0 22.0 22.1 22.2 22.7 24.6 26.0 26.1 26.1 26.2 26.8 29.1 30.0 30.1 30.1 30.2 30.9 33.5 34.0 34.1 34.1 34.3 35.0 38.0 38.0 38.1 38.1 38.3 39.2 42.5 42.0 42.1 42.1 42.3 43.3 47.0 46.0 46.1 46.2 46.4 47.4 51.4 Top Chord Pitch in/ft 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 Shape Depth in 15 18 20 25 40 71 19 22 24 29 44 76 23 26 28 33 49 80 27 30 32 37 53 85 31 34 36 41 57 89 35 38 40 45 61 94 39 42 44 49 65 98 43 46 48 53 69 102 47 50 52 57 73 107 51 54 56 61 77 111 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 19 19 19 19 20 21 11 11 11 11 11 14 10 10 10 10 10 11 9 9 9 10 11 13 9 9 10 10 10 12 10 10 10 10 11 14 10 10 11 11 11 15 11 11 12 12 13 16 12 12 12 12 13 15 12 12 12 12 13 18 19 19 20 20 20 23 12 12 12 12 13 14 10 10 10 10 11 13 10 10 10 10 11 13 10 9 10 10 11 13 10 10 10 11 12 14 11 11 11 12 12 15 12 12 12 12 13 17 12 13 13 12 13 16 12 13 13 14 15 18 20 20 20 21 21 25 13 13 13 13 13 15 11 11 11 11 11 13 10 10 11 11 12 13 10 10 10 11 11 13 11 11 11 11 12 15 11 11 12 12 13 16 12 12 12 12 13 17 12 13 13 12 13 18 13 14 14 14 15 18 Joist Self-Weight - Pounds per Linear Foot (plf) 7 7 7 8 8 9 7 7 7 7 7 8 7 7 7 7 7 7 7 7 7 7 8 8 7 7 7 7 7 8 7 7 7 7 7 9 7 7 7 7 8 10 7 7 7 8 8 11 8 8 8 8 8 11 8 8 8 9 9 12 8 8 8 9 10 10 7 7 7 7 7 8 7 7 7 7 7 8 7 7 7 7 8 9 7 7 7 7 7 9 7 7 7 7 7 10 7 7 7 8 8 10 7 8 8 8 9 11 8 8 8 9 9 11 9 9 9 9 9 13 10 10 10 10 11 12 7 7 7 7 7 9 7 7 7 7 7 8 7 7 7 7 8 9 7 7 7 7 8 9 7 7 7 7 8 10 7 8 8 8 8 11 8 8 8 8 9 12 9 9 9 9 9 12 9 9 9 9 10 13 11 11 11 12 12 14 7 7 7 7 8 10 7 7 7 7 8 9 7 7 7 7 8 10 7 7 7 7 8 9 7 7 7 7 8 11 8 8 8 8 9 11 8 9 9 9 9 12 9 9 9 9 10 13 9 9 9 10 11 14 12 12 12 13 13 15 8 8 8 8 9 10 7 7 7 7 8 9 7 7 7 7 8 10 8 8 8 8 8 10 8 8 8 8 8 11 8 8 8 8 9 12 9 9 9 9 10 13 9 9 9 10 11 14 10 10 10 11 11 14 13 14 14 14 15 16 9 9 9 9 10 11 8 8 8 8 8 10 8 8 8 8 9 10 8 8 8 8 9 10 8 8 8 8 9 12 9 9 9 9 9 12 9 9 9 10 10 14 9 10 10 10 11 14 10 11 11 11 12 15 15 15 15 15 16 18 10 10 10 10 10 12 8 9 9 9 9 10 8 8 8 8 10 11 8 8 9 9 9 11 9 9 9 9 10 12 9 9 9 9 10 13 10 10 10 10 11 15 10 10 11 11 12 15 11 11 11 12 12 16 16 16 16 17 19 21 10 10 10 10 11 13 9 9 9 9 9 11 8 9 9 9 10 12 9 9 9 9 9 12 9 9 9 9 10 13 9 10 10 10 11 13 10 10 10 10 11 15 11 11 11 11 12 15 11 11 12 12 13 17 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 58 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 10 rows Scissor Joist (SPSC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 21 21 21 21 22 27 16 16 16 16 17 18 14 14 14 15 15 17 14 14 14 14 16 18 15 15 15 15 16 20 15 15 15 16 17 21 17 17 17 17 20 24 18 18 19 20 21 27 19 19 19 19 22 27 20 19 19 20 24 29 22 22 23 23 25 29 16 16 17 17 18 20 15 15 16 16 17 18 15 15 16 16 17 20 16 16 17 17 16 20 15 16 16 17 18 21 17 17 18 18 20 25 19 19 21 21 21 29 19 19 19 20 22 27 22 21 21 22 25 31 24 24 24 25 26 30 18 18 18 18 19 22 16 16 16 17 17 19 16 16 16 17 18 21 17 17 17 17 18 21 17 17 17 17 20 23 19 19 19 20 21 27 21 21 21 21 23 29 19 20 20 22 24 29 23 23 23 23 26 31 Joist Self-Weight - Pounds per Linear Foot (plf) 9 9 9 9 9 11 7 7 7 8 8 9 7 7 7 8 8 9 8 8 8 8 9 11 8 9 9 9 9 12 9 9 9 10 10 14 10 10 10 11 12 17 11 11 11 12 13 20 13 13 14 14 16 21 15 14 15 15 20 21 10 10 10 10 11 13 8 8 8 9 9 10 8 8 8 8 9 10 8 8 8 8 10 11 9 9 9 9 10 12 10 10 10 10 11 14 11 11 11 12 12 17 12 12 13 13 14 21 14 14 14 14 16 21 15 14 15 15 20 21 12 12 12 12 13 15 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 12 10 10 10 10 11 13 10 11 11 11 12 15 12 12 12 12 13 17 13 13 14 14 15 21 15 15 15 15 17 21 16 15 15 16 20 22 13 13 13 13 14 17 10 10 10 11 11 13 10 10 10 10 11 12 10 10 10 10 11 14 11 11 11 12 12 14 11 11 11 12 13 15 12 13 13 13 14 17 14 14 14 15 17 21 15 15 17 16 18 21 17 16 16 16 20 27 15 15 15 15 16 19 11 11 12 12 12 14 11 11 11 11 12 13 11 11 11 11 12 14 12 12 12 12 13 16 12 12 12 13 13 17 13 13 13 14 16 20 14 15 15 15 17 21 16 16 17 17 19 22 17 17 17 17 20 27 16 16 16 17 18 21 13 13 13 13 13 15 12 12 12 12 12 14 11 12 12 12 13 16 12 12 13 13 13 16 12 13 13 13 15 17 14 14 14 14 16 21 16 16 16 17 17 23 16 16 17 18 19 24 19 17 19 19 21 27 18 19 19 19 19 23 14 14 14 14 14 16 13 13 13 13 13 15 13 13 13 12 14 16 13 13 13 13 14 17 14 14 14 14 16 18 15 15 15 16 16 21 17 17 17 17 20 25 18 18 19 19 20 25 20 19 19 19 22 27 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 20 20 20 20 21 24 14 14 14 15 16 18 13 13 13 13 15 16 13 14 14 14 15 18 14 14 15 15 16 18 15 15 15 15 17 20 16 16 17 17 18 22 17 17 17 18 20 27 19 19 19 19 21 27 20 19 19 19 24 27 9 rows SP-Series Tables Shape Depth in 24 27 31 39 61 108 30 33 37 45 68 115 36 39 43 51 74 121 42 45 49 57 80 128 48 51 55 63 86 135 54 57 61 69 92 141 60 63 67 75 99 148 66 69 73 81 105 155 72 75 79 87 111 162 78 81 85 93 117 168 SP-Series Design Top Chord Pitch in/ft 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 Special Profile Joists Ridge Depth in 16.0 16.0 16.1 16.1 16.5 17.9 22.0 22.0 22.1 22.2 22.7 24.6 28.0 28.1 28.1 28.2 28.9 31.3 34.0 34.1 34.1 34.3 35.0 38.0 40.0 40.1 40.1 40.3 41.2 44.7 46.0 46.1 46.2 46.4 47.4 51.4 52.0 52.1 52.2 52.4 53.6 58.1 58.1 58.1 58.2 58.5 59.8 64.8 64.1 64.1 64.2 64.5 66.0 71.6 70.1 70.1 70.2 70.5 72.2 78.3 Introduction Span ft 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 Chord Depth in 16 16 16 16 16 16 22 22 22 22 22 22 28 28 28 28 28 28 34 34 34 34 34 34 40 40 40 40 40 40 46 46 46 46 46 46 52 52 52 52 52 52 58 58 58 58 58 58 64 64 64 64 64 64 70 70 70 70 70 70 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 59 Introduction Scissor Joist (SPSC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 Chord Depth in 20 20 20 20 20 20 28 28 28 28 28 28 36 36 36 36 36 36 44 44 44 44 44 44 52 52 52 52 52 52 60 60 60 60 60 60 68 68 68 68 68 68 76 76 76 76 76 76 84 84 84 84 84 84 92 92 92 92 92 92 Ridge Depth in 20.0 20.0 20.1 20.2 20.6 22.4 28.0 28.1 28.1 28.2 28.9 31.3 36.0 36.1 36.1 36.3 37.1 40.2 44.0 44.1 44.2 44.3 45.4 49.2 52.0 52.1 52.2 52.4 53.6 58.1 60.1 60.1 60.2 60.5 61.8 67.1 68.1 68.1 68.2 68.5 70.1 76.0 76.1 76.1 76.3 76.6 78.3 85.0 84.1 84.2 84.3 84.7 86.6 93.9 92.1 92.2 92.3 92.7 94.8 102.9 Top Chord Pitch in/ft 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 Shape Depth in 30 35 40 50 81 142 38 43 48 58 89 151 46 51 56 66 97 160 54 59 64 74 105 169 62 67 72 82 114 178 70 75 80 90 122 187 78 83 88 99 130 196 86 91 96 107 138 205 94 99 104 115 147 214 102 107 112 123 155 223 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 31 31 31 31 33 40x>2 22 22 21 22 22 27 19 19 19 19 21 24 19 19 20 21 21 26 21 21 21 21 22 26 22 22 22 23 25 29 24 24 25 25 27 33 26 26 26 28 29 41 28 29 29 30 31 42 31 30 30 32 38 46 33 35 35 35 36 42x>2 22 22 22 23 24 27 21 21 21 21 22 26 22 22 22 22 22 26 22 22 22 22 24 29 22 23 23 23 27 31 25 25 25 26 28 35 27 28 29 29 29 41 30 30 30 30 33 42 31 32 32 33 38 46 36 36 36 37 39 48x>2 24 24 24 24 26 29 21 21 21 21 23 26 22 22 22 22 23 29 22 23 23 23 25 29 24 24 26 26 27 32 26 27 27 28 29 40 29 28 30 30 32 42 30 30 30 31 38 46 32 32 33 34 38 54 Joist Self-Weight - Pounds per Linear Foot (plf) 13 13 13 13 14 17x>2 10 10 10 10 11 13 10 10 10 10 10 12 10 10 11 11 12 15 11 12 12 12 13 17 14 14 15 15 16 22 15 15 16 16 18 24 17 17 17 18 21 30 21 21 21 23 23 40 24 24 24 24 29 41 16 16 16 16 16 20x>2 12 12 12 12 12 14 11 11 11 11 12 13 12 12 13 13 13 15 12 12 13 13 14 17 15 15 15 16 16 22 16 16 16 16 18 24 17 17 18 19 21 30 21 21 21 23 23 40 24 24 24 24 29 41 18 18 18 19 19 22x>2 13 13 13 13 14 16 12 12 12 12 13 15 13 13 13 13 14 17 13 13 13 14 14 18 16 16 17 17 18 22 17 17 17 17 19 25 19 19 19 19 22 30 23 24 23 23 23 41 25 25 24 24 29 41 20 20 20 20 21 25x>2 14 14 14 15 16 17 13 13 14 13 14 17 14 14 14 14 15 18 14 14 14 14 16 20 16 17 18 18 19 22 17 17 18 19 21 27 20 20 20 22 22 30 24 24 24 24 26 41 25 26 26 27 29 41 22 22 22 23 24 28x>2 16 16 16 16 18 20 15 15 15 15 15 18 15 15 15 15 17 20 15 16 16 16 17 20 18 18 18 19 20 25 19 19 20 20 21 29 22 22 22 22 24 31 24 24 24 25 28 41 26 27 27 29 30 41 24 24 24 25 26 31x>2 17 17 17 17 18 20 15 15 16 17 16 19 16 16 17 17 17 21 16 16 16 17 19 22 18 19 19 21 21 25 20 20 21 21 22 30 23 23 23 23 25 31 25 25 27 27 29 41 27 29 29 30 30 41 27 27 27 27 29 33x>2 19 19 19 19 20 22 17 17 17 17 18 21 17 17 17 17 19 22 18 18 18 18 20 24 20 21 21 21 21 27 21 21 21 21 24 30 23 23 24 24 27 33 27 27 27 28 29 42 29 29 30 30 31 41 28 30 30 30 30 36x>2 20 20 20 20 22 24 18 18 18 18 19 22 18 19 19 19 21 24 19 19 20 20 20 25 21 21 21 21 23 28 22 22 23 23 26 31 24 24 25 26 29 35 27 28 28 29 29 42 30 30 30 30 33 42 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 60 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 10 rows Scissor Joist (SPSC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 35 35 35 35 37 44x>2 27 27 27 27 29 33x>2 23 23 23 25 26 30 25 26 26 26 28 32 26 26 28 28 29 39 29 29 30 30 32 41 31 31 32 32 41 49 37 37 37 42 43 59 46 45 45 45 49 60 43 43 43 43 51 61 38 38 38 38 41 49x>2 29 29 29 30 29 33x>2 25 25 25 25 27 31 27 27 27 29 30 34 28 28 28 29 31 40 31 31 31 31 32 41 31 31 32 33 41 50 37 42 42 42 43 59 46 45 45 45 49 60 44 44 43 47 55 61 40 40 40 44 45 54x>2 29 29 29 31 31 36x>2 25 25 27 27 29 33 29 29 29 29 31 36 30 30 30 30 34 41 31 31 31 33 34 41 32 34 34 36 41 54 42 43 43 43 44 60 46 45 46 45 50 61 44 48 47 47 58 75 Joist Self-Weight - Pounds per Linear Foot (plf) 16 16 16 16 16 19x>2 12 12 12 13 13 16 12 12 12 12 13 15 14 14 14 14 15 20 16 16 17 17 19 23 20 20 20 21 23 31 21 22 22 24 30 43 26 26 26 31 32 57 38 37 37 37 45 60 36 36 35 43 47 61 18 18 18 18 18 21x>2 14 14 15 15 15 18 14 14 13 13 15 17 15 15 15 15 17 23 17 17 18 18 20 24 21 21 21 21 23 31 22 23 23 24 30 43 26 26 26 31 32 57 38 37 37 37 45 60 36 36 35 43 47 61 20 20 20 20 21 25x>2 16 16 17 17 17 20 15 15 15 15 16 19 17 17 17 17 18 23 18 18 18 18 21 26 22 22 22 23 24 31 24 24 24 25 30 43 27 27 29 31 32 57 38 37 37 37 45 60 36 36 35 43 47 61 22 22 22 22 24 28x>2 18 18 18 18 18 22 17 17 17 17 18 21 18 18 18 18 21 24 19 19 19 21 21 28 23 23 23 23 24 31 24 24 25 26 31 44 30 30 31 32 33 57 38 37 37 37 45 60 36 36 35 43 47 61 25 25 25 25 26 32x>2 20 20 20 20 21 23x>2 18 18 18 19 20 23 19 19 19 21 21 26 21 21 21 21 24 30 24 24 24 25 26 31 26 26 26 27 31 44 31 32 32 32 34 57 38 37 37 39 45 60 37 37 37 43 47 61 27 27 27 28 29 35x>2 22 22 22 22 22 25x>2 19 19 19 20 21 25 22 22 22 22 23 28 22 22 22 23 24 30 25 25 25 27 28 35 27 27 27 29 31 44 33 33 33 33 37 57 38 39 39 40 46 60 38 39 38 43 47 61 30 30 30 30 32 39x>2 22 24 24 24 24 28x>2 21 21 21 21 23 26 23 23 23 24 26 30 23 23 23 25 27 32 27 27 27 28 30 41 27 29 29 30 32 44 34 34 34 35 42 58 39 40 40 45 46 60 43 43 43 43 47 61 31 32 33 33 34 40x>2 24 24 24 26 26 30x>2 21 21 23 23 24 28 24 24 24 24 26 31 25 25 25 25 28 34 27 28 28 28 30 41 29 30 31 31 35 44 35 35 35 37 42 59 41 45 45 45 46 60 43 43 43 43 51 61 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables Shape Depth in 39 45 51 64 102 179 49 55 61 74 112 190 59 65 71 84 122 201 69 75 81 94 133 213 79 85 91 104 143 224 89 95 101 114 153 235 99 105 111 124 164 246 109 115 121 134 174 257 119 125 131 144 184 269 129 135 141 154 195 280 SP-Series Design Top Chord Pitch in/ft 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 Special Profile Joists Ridge Depth in 26.0 26.1 26.1 26.2 26.8 29.1 36.0 36.1 36.1 36.3 37.1 40.2 46.0 46.1 46.2 46.4 47.4 51.4 56.0 56.1 56.2 56.4 57.7 62.6 66.1 66.1 66.2 66.5 68.0 73.8 76.1 76.1 76.3 76.6 78.3 85.0 86.1 86.2 86.3 86.7 88.6 96.2 96.1 96.2 96.3 96.7 99.0 107.3 106.1 106.2 106.4 106.8 109.3 118.5 116.1 116.2 116.4 116.9 119.6 129.7 Introduction Span ft 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 Chord Depth in 26 26 26 26 26 26 36 36 36 36 36 36 46 46 46 46 46 46 56 56 56 56 56 56 66 66 66 66 66 66 76 76 76 76 76 76 86 86 86 86 86 86 96 96 96 96 96 96 106 106 106 106 106 106 116 116 116 116 116 116 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 61 Introduction Scissor Joist (SPSC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 Chord Depth in 30 30 30 30 30 30 40 40 40 40 40 40 50 50 50 50 50 50 60 60 60 60 60 60 70 70 70 70 70 70 80 80 80 80 80 80 90 90 90 90 90 90 100 100 100 100 100 100 110 110 110 110 110 110 120 120 120 120 120 120 Ridge Depth in 30.0 30.1 30.1 30.2 30.9 33.5 40.0 40.1 40.1 40.3 41.2 44.7 50.0 50.1 50.2 50.4 51.5 55.9 60.1 60.1 60.2 60.5 61.8 67.1 70.1 70.1 70.2 70.5 72.2 78.3 80.1 80.2 80.3 80.6 82.5 89.4 90.1 90.2 90.3 90.7 92.8 100.6 100.1 100.2 100.3 100.8 103.1 111.8 110.1 110.2 110.4 110.9 113.4 123.0 120.1 120.2 120.4 120.9 123.7 134.2 Top Chord Pitch in/ft 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 Shape Depth in 45 53 60 75 121 214 55 63 70 85 131 225 65 73 80 95 142 236 75 83 90 105 152 247 85 93 100 116 162 258 95 103 110 126 172 269 105 113 120 136 183 281 115 123 130 146 193 292 125 133 140 156 203 303 135 143 150 166 214 314 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 49 49 49 49 50 58x>2 32 32 34 34 36 39x>2 30 30 31 31 32 38x>2 31 30 31 31 32 42 32 31 32 32 36 44 34 34 34 36 41 48 38 38 38 42 43 57 43 43 43 44 46 61 44 45 46 46 54 66 58 58 58 57 64 81 49 49 49 49 54 62x>2 35 35 35 37 38 46x>2 32 32 32 33 35 45x>2 32 32 32 32 34 42 32 32 32 34 41 44 36 36 36 40 41 49 43 42 42 43 43 57 43 43 43 44 49 61 45 45 46 46 54 66 58 58 58 61 64 81 53 53 54 54 55 66x>2 38 38 38 38 44 47x>2 34 35 35 36 38 46x>2 34 34 34 34 35 43 34 34 34 36 41 45 36 40 40 41 41 53 43 43 43 43 43 61 43 43 43 44 50 62 45 45 46 50 58 71 58 61 61 61 64 81 Joist Self-Weight - Pounds per Linear Foot (plf) 19 19 19 20 20 23x>2 16 16 16 16 18 19x>2 15 15 15 15 16 19 17 17 17 18 18 22 19 20 20 20 24 26 22 22 23 24 24 42 28 28 28 28 33 48 30 30 30 35 37 60 35 35 36 37 44 63 54 54 54 54 61 80 22 22 23 23 23 27x>2 18 18 18 18 19 22x>2 18 18 18 18 18 23 18 18 19 19 20 23 20 20 20 21 24 32 24 24 24 24 26 42 29 29 29 30 34 48 30 31 31 35 37 60 35 36 36 37 44 63 54 54 54 54 61 80 25 25 25 26 27 31x>2 20 20 20 21 23 24x>2 19 19 19 20 21 24 20 20 20 21 21 26 23 23 23 23 25 32 24 24 24 25 27 42 30 30 30 31 34 48 33 32 33 35 37 60 35 36 36 37 44 63 54 54 54 54 61 80 28 28 28 29 30 35x>2 22 22 22 22 25 27x>2 22 22 22 22 22 27 22 22 22 22 23 28 23 23 23 23 27 32 26 26 27 27 29 42 31 31 33 33 34 48 34 34 34 35 37 60 35 36 36 37 45 63 54 54 54 54 61 80 31 31 31 32 33 40x>2 24 25 25 25 27 30x>2 22 22 22 22 24 29x>2 23 23 24 24 26 30 25 25 25 26 29 33 27 27 29 29 30 43 33 33 34 34 36 48 35 35 35 36 40 60 35 36 38 39 45 63 54 54 54 54 62 80 35 35 35 35 37 44x>2 27 27 27 27 30 33x>2 24 24 24 24 26 32x>2 24 26 26 26 28 31 28 27 28 28 30 34 29 29 30 30 30 43 34 34 34 34 37 49 35 35 35 37 45 60 37 38 40 41 45 64 54 54 54 54 62 80 38 38 38 38 41 49x>2 29 29 29 29 31 34x>2 26 26 26 27 29 33x>2 27 27 27 29 30 33 29 29 29 29 32 37 30 30 31 31 32 43 34 34 36 36 42 53 37 37 37 39 45 60 39 39 45 45 46 64 54 54 54 54 63 80 44 44 44 45 45 54x>2 32 32 32 32 34 37x>2 29 29 29 29 31 36x>2 29 29 29 30 31 36 31 31 32 32 34 43 32 32 32 34 36 44 36 36 38 38 43 53 39 39 39 43 46 60 44 44 45 46 50 64 54 54 54 57 64 80 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 62 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 10 rows Scissor Joist (SPSC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 50 50 50 50 55 63x>2 39 39 39 44 45 49x>2 37 37 37 38 43 47x>2 34 35 35 35 41 44x>2 35 36 37 37 42 51 38 38 38 43 42 58 47 47 47 47 51 62 49 49 49 50 53 71 51 51 55 55 59 75 53 53 53 57 64 89 54 54 54 54 59 67x>2 45 45 45 45 46 50x>2 39 39 43 44 45 49x>2 37 37 42 42 42 50 37 37 42 42 43 51 43 43 43 44 47 62 47 47 47 47 51 63 49 49 49 53 57 71 55 55 55 55 63 89 54 54 57 57 64 89 57 58 58 58 63 71x>2 47 47 47 47 48 56x>2 44 44 44 44 45 54x>2 42 43 43 43 44 51x>2 42 42 42 42 43 56 44 44 44 44 47 62 47 47 51 51 55 63 53 53 53 54 61 76 55 55 58 59 63 90 57 57 57 61 64 89 Joist Self-Weight - Pounds per Linear Foot (plf) 21 21 22 22 23 26x>2 18 19 19 19 20 23x>2 18 18 18 18 20 23x>2 18 18 19 19 22 26 21 22 23 23 25 33 25 25 26 27 33 47 33 33 33 38 38 61 40 40 40 41 49 69 42 43 42 50 51 74 49 49 49 49 63 88 25 25 25 25 26 30x>2 22 22 22 23 23 26x>2 20 20 21 21 22 26x>2 21 21 21 21 23 29 24 24 24 24 26 34 26 27 27 27 33 47 35 36 36 38 38 61 40 40 40 41 49 69 42 43 42 50 51 74 49 49 49 49 63 88 27 29 29 29 31 35x>2 24 24 24 24 25 29x>2 22 22 22 23 24 30x>2 22 22 22 23 25 31 24 24 25 25 28 34 27 28 28 29 33 48 37 37 37 38 39 61 40 40 40 41 49 69 43 43 43 50 51 74 49 49 49 49 63 88 32 32 32 32 34 39x>2 27 27 27 28 28 32x>2 24 24 26 26 27 32x>2 24 24 26 26 28 31 26 27 27 27 29 36 29 29 30 31 33 48 38 38 38 38 41 61 41 41 40 43 49 69 44 44 44 50 51 74 49 49 49 49 63 89 35 35 36 36 37 44x>2 30 30 30 30 31 35x>2 27 27 27 29 30 34x>2 27 27 28 28 30 35 28 30 30 30 32 38 31 31 31 32 37 48 38 38 40 40 46 61 42 42 44 45 49 69 46 46 50 50 51 75 49 49 49 49 63 89 39 39 39 39 41 50x>2 32 32 33 33 34 38x>2 30 30 30 31 33 39x>2 29 29 30 30 32 41 31 32 32 32 33 44 34 35 35 35 41 49 40 42 42 42 47 61 44 44 48 49 49 69 50 50 50 50 52 75 49 49 49 49 63 89 45 45 45 45 47 55x>2 34 35 35 36 36 42x>2 32 32 32 32 35 45x>2 30 30 30 30 34 42 32 32 32 32 36 46 35 35 36 36 42 53 42 46 46 46 47 62 49 49 49 50 49 70 51 51 50 51 56 75 49 49 49 53 63 89 50 50 49 50 51 59x>2 36 37 37 38 39 47x>2 35 35 36 36 38 47x>2 32 33 33 33 40 43 32 34 34 34 36 47 36 36 38 38 42 57 46 46 46 47 47 62 49 49 49 50 53 70 51 51 51 51 59 75 49 49 53 54 64 89 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables Shape Depth in 54 62 71 89 142 250 64 72 81 99 152 261 74 82 91 109 163 273 84 92 101 119 173 284 94 102 111 129 183 295 104 112 121 139 194 306 114 122 131 149 204 317 124 132 141 159 214 329 134 142 151 169 225 340 144 152 161 179 235 351 SP-Series Design Top Chord Pitch in/ft 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 Special Profile Joists Ridge Depth in 36.0 36.1 36.1 36.3 37.1 40.2 46.0 46.1 46.2 46.4 47.4 51.4 56.0 56.1 56.2 56.4 57.7 62.6 66.1 66.1 66.2 66.5 68.0 73.8 76.1 76.1 76.3 76.6 78.3 85.0 86.1 86.2 86.3 86.7 88.6 96.2 96.1 96.2 96.3 96.7 99.0 107.3 106.1 106.2 106.4 106.8 109.3 118.5 116.1 116.2 116.4 116.9 119.6 129.7 126.1 126.2 126.4 127.0 129.9 140.9 Introduction Span ft 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 Chord Depth in 36 36 36 36 36 36 46 46 46 46 46 46 56 56 56 56 56 56 66 66 66 66 66 66 76 76 76 76 76 76 86 86 86 86 86 86 96 96 96 96 96 96 106 106 106 106 106 106 116 116 116 116 116 116 126 126 126 126 126 126 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 63 Introduction Scissor Joist (SPSC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 Chord Depth in 40 40 40 40 40 40 50 50 50 50 50 50 60 60 60 60 60 60 70 70 70 70 70 70 80 80 80 80 80 80 90 90 90 90 90 90 100 100 100 100 100 100 110 110 110 110 110 110 120 120 120 120 120 120 130 130 130 130 130 130 Ridge Depth in 40.0 40.1 40.1 40.3 41.2 44.7 50.0 50.1 50.2 50.4 51.5 55.9 60.1 60.1 60.2 60.5 61.8 67.1 70.1 70.1 70.2 70.5 72.2 78.3 80.1 80.2 80.3 80.6 82.5 89.4 90.1 90.2 90.3 90.7 92.8 100.6 100.1 100.2 100.3 100.8 103.1 111.8 110.1 110.2 110.4 110.9 113.4 123.0 120.1 120.2 120.4 120.9 123.7 134.2 130.1 130.2 130.3 130.7 131.8 137.0 Top Chord Pitch in/ft 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.375 0.625 0.875 1.250 2.000 4.000 Shape Depth in 60 70 80 100 161 285 70 80 90 110 172 296 80 90 100 120 182 307 90 100 110 131 192 318 100 110 120 141 202 329 110 120 130 151 213 341 120 130 140 161 223 352 130 140 150 171 233 363 140 150 160 181 244 374 145 155 165 181 212 297 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 61 61 61 62 63x>2 75x>2 51 51 51 52 48 56x>2 45 45 45 45 46 54x>2 43 43 43 43 44 55x>2 44 44 44 44 44 56x>2 43 43 44 44 48 65 47 47 48 51 56 68 49 53 53 53 67 76 62 66 66 66 70 87 63 62 66 67 73 72 65 65 65 65 67x>2 78x>2 52 55 55 56 57 61x>2 46 47 47 47 51 55x>2 45 45 45 45 50 59x>2 45 45 45 45 49 60x>2 45 45 45 45 50 66 48 51 51 51 60 68 53 53 53 56 67 77 66 66 66 70 70 87 67 67 67 67 73 72 69 69 69 69 74x>2 84x>2 56 56 56 56 57 65x>2 48 48 48 52 53 61x>2 46 46 46 46 51 61x>2 46 46 47 50 50 62x>2 47 50 51 51 54 66 52 52 52 52 60 68 53 53 57 57 67 86 66 70 70 70 70 87 68 67 71 71 73 77 Joist Self-Weight - Pounds per Linear Foot (plf) 25 25 25 26 27x>2 30x>2 22 22 22 23 24 28x>2 22 22 22 22 22 27x>2 22 23 23 23 25 32 25 25 26 26 26 43 29 29 29 30 34 50 34 34 34 38 42 65 40 40 40 40 55 70 57 57 57 57 69 86 51 58 58 58 60 71 29 29 30 30 31x>2 36x>2 25 25 25 25 27 31x>2 24 24 24 25 27 29x>2 23 24 24 24 26 32x>2 27 27 27 28 29 44 31 32 32 32 35 51 36 36 37 38 42 65 41 41 41 41 55 71 57 57 57 57 69 86 51 58 58 58 60 72 33 33 33 35 36x>2 41x>2 28 28 28 29 30 33x>2 27 27 27 27 29 32x>2 26 26 26 27 29 34x>2 28 28 30 30 31 44 33 33 33 35 35 51 38 38 38 38 44 66 41 41 41 41 55 71 57 57 57 57 69 86 52 58 58 58 60 72 37 37 37 39 40x>2 49x>2 31 33 33 33 33 37x>2 30 30 30 30 31 35x>2 29 29 29 30 31 38x>2 30 31 32 32 33 45 34 34 35 35 37 52 39 39 39 40 46 66 42 42 42 44 55 71 57 57 57 57 69 86 58 58 58 58 60 72 45 45 45 45 45x>2 54x>2 34 35 35 36 35 40x>2 32 32 33 33 35 43x>2 31 31 31 31 35 45x>2 33 34 34 35 37 45 35 36 36 36 43 52 41 41 42 42 51 66 44 44 48 48 56 71 57 57 57 57 70 86 58 58 58 58 60 72 49 49 50 50 51 59x>2 38 39 39 39 38 47x>2 36 36 36 36 38 46x>2 34 34 34 34 41 46x>2 35 35 35 37 42 45 36 38 38 38 44 56 42 47 47 47 51 67 48 48 48 48 59 71 57 57 57 57 70 86 58 58 58 58 72 72 50 50 50 54 55x>2 63x>2 45 45 45 45 46 49x>2 39 39 39 39 43 46x>2 37 37 37 37 42 47x>2 37 37 37 42 42 50 38 43 43 43 44 57 47 47 47 47 51 67 48 48 48 48 59 71 58 58 61 61 70 87 59 58 58 62 72 72 54 57 57 58 59 67x>2 47 47 47 47 48 50x>2 44 44 44 44 45 48x>2 43 43 43 43 44 53x>2 42 42 42 43 42 55x>2 43 43 43 43 44 61 47 47 47 47 56 67 49 49 49 52 63 71 62 62 62 65 70 87 63 62 63 63 72 72 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 64 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 10 rows Scissor Joist (SPSC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 62 65 66 66 67x>2 79x>2 56 56 56 56 58 66x>2 49 52 52 53 54 62x>2 47 47 47 48 52 61x>2 46 46 46 50 54 64x>2 53 53 53 53 54 63 55 55 55 55 59 65 60 64 63 64 68 70 65 65 65 69 69 71 68 67 67 71 71 73 69 69 69 70 71x>2 84x>2 56 60 60 60 62 71x>2 56 57 57 57 58 67x>2 53 53 53 53 54 66x>2 51 50 50 51 55 65x>2 53 53 53 57 57 64 55 58 59 58 59 65 64 64 64 68 68 75 65 69 69 69 69 76 68 67 71 71 71 78 73 73 73 74 79x>2 89x>2 63 63 64 64 66 75x>2 57 57 60 61 62 71x>2 54 54 54 55 60 69x>2 52 52 52 52 60 70x>2 57 57 57 57 61 64 59 59 59 63 63 66 64 68 68 68 68 75 69 69 69 69 69 76 72 71 71 71 72 78 Joist Self-Weight - Pounds per Linear Foot (plf) 28 28 28 28 30x>2 34x>2 24 24 25 26 27 33x>2 25 25 25 24 26 31x>2 24 24 24 26 28 34x>2 26 27 27 27 34 49 37 37 37 37 40 49 42 42 42 42 43 51 48 48 48 48 56 68 50 57 57 58 58 70 53 60 60 60 70 72 32 32 32 32 33x>2 38x>2 29 29 29 30 30 34x>2 27 27 27 27 29 35x>2 28 28 28 28 30 36x>2 28 28 28 30 34 49 38 39 39 40 40 49 42 42 42 42 43 52 48 48 48 48 56 69 50 58 58 58 58 70 53 60 60 60 70 72 36 36 36 36 39x>2 45x>2 33 33 33 33 34 40x>2 30 30 32 32 32 38x>2 30 30 30 32 32 40x>2 30 31 31 31 36 49 40 40 40 40 42 49 42 42 44 44 46 52 50 50 51 56 56 69 58 58 58 58 58 70 61 60 60 60 70 72 41 41 41 45 45x>2 50x>2 36 36 36 36 39 48x>2 33 33 33 34 37 45x>2 33 33 34 34 36 46x>2 34 34 34 35 42 50 41 41 41 43 43 50 45 45 45 46 51 52 52 56 56 56 56 69 58 58 58 58 58 70 61 60 60 60 71 72 46 46 46 46 51x>2 55x>2 39 39 39 44 45 49x>2 38 38 38 38 43 47x>2 36 36 36 38 43 47x>2 35 35 37 37 42 54 43 43 47 48 48 51 50 50 50 50 51 56 56 56 56 56 56 69 58 58 58 58 62 70 61 60 60 60 71 72 50 50 51 51 51x>2 63x>2 45 45 46 46 47 51x>2 43 44 44 44 45 49x>2 39 39 39 44 45 54x>2 37 37 42 42 43 59 48 48 48 48 48 55 51 50 50 51 51 57 56 56 56 56 60 69 58 58 58 62 62 70 61 60 60 64 71 72 54 54 55 55 59x>2 67x>2 47 47 48 48 49 57x>2 45 45 45 45 46 54x>2 46 46 46 46 47 55x>2 43 43 43 43 48 59x>2 48 48 48 48 49 55 51 51 51 51 55 61 56 56 60 60 60 69 62 62 62 62 65 70 65 64 64 64 71 72 58 58 59 59 63x>2 71x>2 52 56 56 56 57 66x>2 47 47 47 47 52 60x>2 46 46 46 46 47 59x>2 44 44 44 45 50 63x>2 49 49 49 53 53 59 51 54 54 54 55 65 60 60 60 60 64 69 62 62 65 65 69 70 65 64 67 67 71 72 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables Shape Depth in 69 80 91 114 182 321 79 90 101 124 193 333 89 100 111 134 203 344 99 110 121 144 213 355 109 120 131 154 224 366 113 124 136 153 187 281 123 134 146 163 197 292 133 144 156 173 208 302 143 154 166 183 218 313 153 164 176 193 228 323 SP-Series Design Top Chord Pitch in/ft 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 Special Profile Joists Ridge Depth in 46.0 46.1 46.2 46.4 47.4 51.4 56.0 56.1 56.2 56.4 57.7 62.6 66.1 66.1 66.2 66.5 68.0 73.8 76.1 76.1 76.3 76.6 78.3 85.0 86.1 86.2 86.3 86.7 88.6 96.2 96.0 96.1 96.3 96.5 97.3 101.2 106.1 106.1 106.3 106.6 107.5 111.7 116.1 116.2 116.3 116.6 117.6 122.3 126.1 126.2 126.3 126.7 127.7 132.8 136.1 136.2 136.4 136.7 137.9 143.4 Introduction Span ft 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 Chord Depth in 46 46 46 46 46 46 56 56 56 56 56 56 66 66 66 66 66 66 76 76 76 76 76 76 86 86 86 86 86 86 96 96 96 96 96 96 106 106 106 106 106 106 116 116 116 116 116 116 126 126 126 126 126 126 136 136 136 136 136 136 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 65 Introduction Scissor Joist (SPSC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Chord Depth in 50 50 50 50 50 50 58 58 58 58 58 58 66 66 66 66 66 66 74 74 74 74 74 74 82 82 82 82 82 82 90 90 90 90 90 90 98 98 98 98 98 98 106 106 106 106 106 106 114 114 114 114 114 114 122 122 122 122 122 122 Ridge Depth in 50.0 50.1 50.2 50.4 51.5 55.9 58.1 58.1 58.2 58.5 59.8 64.8 66.0 66.1 66.2 66.4 66.9 69.6 74.0 74.1 74.2 74.4 75.0 78.0 82.0 82.1 82.2 82.4 83.1 86.4 90.0 90.1 90.2 90.5 91.2 94.9 98.0 98.1 98.3 98.5 99.4 103.3 106.1 106.1 106.3 106.6 107.5 111.7 114.1 114.2 114.3 114.6 115.6 120.2 122.1 122.2 122.3 122.7 123.7 128.6 Top Chord Pitch in/ft 0.500 0.750 1.000 1.500 3.000 6.000 0.500 0.750 1.000 1.500 3.000 6.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 Shape Depth in 75 88 100 125 202 356 83 96 108 133 210 365 85 97 110 129 167 270 93 105 118 137 175 278 101 113 126 145 183 286 109 121 134 153 191 295 117 129 142 161 199 303 125 137 150 169 207 312 133 145 158 177 216 320 141 153 166 185 224 329 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 32 32 32 32 33x>2 38x>2 29 30 30 30 31x>2 35x>2 28 28 28 28 30 32x>2 27 27 27 27 29 31x>2 28 29 29 29 31 33 31 31 31 33 33 36 39 39 39 40 40 48 41 41 41 42 42 51 50 50 50 50 58 72 49 57 57 57 57 74 36 36 36 36 39x>2 46x>2 33 33 33 35 36x>2 45x>2 32 33 33 33 33 36x>2 31 31 32 32 32 34x>2 32 32 34 34 34 37 34 34 34 34 34 38 40 40 40 40 41 49 42 41 41 42 44 52 50 52 52 52 58 72 51 57 57 57 57 74 44 44 44 44 45x>2 50x>2 36 38 38 38 39x>2 47x>2 36 36 36 36 36 40x>2 34 34 35 35 35 38x>2 34 34 34 36 36 39 34 36 36 36 37 45 41 41 41 43 43 49 43 43 45 45 50 52 53 53 53 58 58 72 57 57 57 57 57 74 50 50 50 50 51x>2 60x>2 45 45 45 46 46x>2 50x>2 39 39 39 40 44 46x>2 38 38 38 38 43 45x>2 38 38 38 38 43 45 37 37 37 42 42 46 43 43 48 48 48 49 50 50 50 50 51 52 58 58 58 58 58 73 58 58 58 58 58 74 54 54 54 55 56x>2 63x>2 47 47 47 47 48x>2 56x>2 45 45 45 46 46 48x>2 45 45 45 45 45 46x>2 44 44 44 44 45 47 43 43 43 43 44 47 48 48 49 49 49 54 50 50 50 50 51 56 58 58 58 58 62 73 58 58 58 62 62 75 58 58 58 58 60x>2 72x>2 52 52 55 56 57x>2 65x>2 48 48 48 49 49 55x>2 46 46 46 46 47 52x>2 46 46 46 46 47 53 45 45 45 45 45 53 49 49 49 49 53 54 50 50 50 50 55 61 58 58 62 62 62 73 62 62 62 62 66 75 62 62 62 62 67x>2 76x>2 56 56 56 56 57x>2 65x>2 53 57 57 57 57 60x>2 48 48 48 51 52 53x>2 48 48 48 48 52 54x>2 47 47 47 50 51 58 49 49 53 53 53 58 54 54 54 54 55 65 62 62 62 62 66 74 62 62 65 65 69 76 66 69 69 70 71x>2 84x>2 60 60 60 60 61x>2 70x>2 57 57 57 57 58 64x>2 53 53 53 53 53 59x>2 53 53 53 53 54 59x>2 51 51 51 51 51 60 53 53 53 53 57 62 54 54 54 58 59 65 62 66 66 66 70 74 66 66 66 69 69 76 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 73 73 73 73 79x>2 90x>2 63 63 64 64 69x>2 74x>2 61 61 61 62 62 68x>2 58 58 58 62 62 64x>2 54 55 55 55 59 65 52 52 52 55 56 65 53 57 57 57 57 63 58 58 58 58 63 66 66 66 66 70 70 80 69 69 69 69 69 81 78 78 78 82 84x>2 99x>2 67 67 67 67 69x>2 80x>2 65 65 65 65 69 72x>2 61 62 62 62 62 68x>2 63 62 63 63 63 69 57 57 57 57 61 67 57 57 57 61 61 63 58 58 58 62 63 66 70 70 70 70 71 80 69 69 69 69 69 82 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 66 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 800 Joist Self-Weight - Pounds per Linear Foot (plf) 82 90 91 91 93x>2 107x>2 70 71 71 71 77x>2 84x>2 68 69 69 69 70 73x>2 62 65 65 65 66 68x>2 63 63 63 67 67 70 59 59 62 63 63 67 62 62 62 62 63 69 62 62 62 63 63 71 70 70 71 71 71 89 69 70 70 70 74 90 10 rows Scissor Joist (SPSC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 79 79 79 79 80 87x>2 71 71 72 72 72 79x>2 69 69 69 69 70 72x>2 62 65 65 66 66 69x>2 63 63 63 67 67 70x>2 59 63 63 63 63 69x>2 63 63 63 63 63 70 70 70 70 70 71 78 71 71 72 72 72 81 72 72 72 73 75 82 83 83 83 84 92 95x>2 76 76 76 76 77 80x>2 69 69 69 70 70 78x>2 66 66 66 66 66 74x>2 67 67 67 68 68 76x>2 67 67 67 67 68 78 65 65 65 65 65 72 70 70 71 71 71 78 72 72 72 72 78 90 73 73 73 73 80 91 Joist Self-Weight - Pounds per Linear Foot (plf) 35 35 36 36 36 39x>2 32 32 32 32 34 35x>2 32 32 32 32 33 35x>2 33 33 33 33 33 36x>2 34 34 34 34 35 37 39 39 39 39 40 50 41 41 41 41 42 50 50 50 50 50 58 71 51 59 59 59 59 73 52 60 60 60 62 74 40 40 40 40 45 45x>2 36 38 38 38 38 45x>2 36 36 36 37 37 45x>2 35 35 35 35 35 43x>2 34 34 36 36 36 44x>2 41 41 41 41 43 50 43 43 42 44 44 50 51 53 53 53 58 71 54 59 59 59 59 73 60 60 60 60 62 74 46 47 47 47 47 49x>2 44 44 44 44 45 46x>2 40 40 40 44 45 47x>2 39 39 39 39 44 45x>2 38 38 39 39 44 45x>2 43 43 47 47 47 51 49 49 49 49 49 51 57 57 57 57 58 71 59 59 59 59 59 73 60 60 60 60 62 74 51 51 51 52 56 57x>2 47 47 48 48 48 50x>2 46 46 46 46 46 48x>2 45 45 45 45 45 47x>2 45 45 45 45 45 47x>2 47 47 47 47 48 55 49 49 49 49 49 55 57 58 58 58 58 71 59 59 59 59 63 74 60 60 60 60 66 74 55 55 56 56 60 62x>2 56 56 56 56 56 58x>2 49 49 49 49 50 55x>2 47 47 46 47 47 52x>2 47 47 47 47 47 53x>2 48 48 48 48 52 56 49 49 49 53 53 59 58 58 58 62 62 71 63 63 63 63 63 74 60 64 64 64 66 75 63 63 63 63 64 69x>2 56 56 56 56 57 63x>2 57 57 57 58 58 64x>2 52 52 52 52 53 58x>2 48 52 52 52 52 58x>2 52 52 52 52 52 60 53 53 53 53 57 63 62 62 62 62 66 72 63 63 63 67 67 74 64 64 64 68 73 75 67 70 70 70 71 74x>2 63 63 64 64 61 67x>2 58 58 58 62 62 64x>2 54 54 54 54 58 60x>2 53 53 53 54 58 60x>2 52 52 52 56 56 64x>2 54 54 57 57 58 63 62 66 66 66 70 72 66 67 67 67 71 75 68 68 68 68 74 76 74 74 74 74 75 82x>2 67 67 67 68 68 71x>2 62 62 62 62 63 69x>2 61 61 62 62 62 68x>2 59 59 59 59 60 66x>2 58 57 57 58 62 66x>2 57 57 57 61 61 64 66 66 66 70 70 73 71 71 71 71 71 80 69 72 72 72 74 81 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows 92 92 92 92 93 103x>2 79 80 80 80 81 92x>2 73 73 78 78 79 82x>2 70 70 70 70 75 78x>2 68 68 68 68 69 76x>2 68 68 68 68 73 78x>2 65 65 65 65 70 81 71 71 71 75 76 87 72 72 77 77 78 90 73 74 74 78 80 91 SP-Series Tables Shape Depth in 77 90 104 125 167 279 85 98 112 133 175 287 93 106 120 141 183 296 101 114 128 149 191 304 109 122 136 157 199 313 117 131 144 165 207 321 125 139 152 173 215 330 133 147 160 181 224 338 141 155 168 189 232 346 149 163 176 197 240 355 SP-Series Design Top Chord Pitch in/ft 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 Special Profile Joists Ridge Depth in 56.0 56.1 56.1 56.3 56.8 59.0 64.0 64.1 64.2 64.3 64.9 67.5 72.0 72.1 72.2 72.4 73.0 75.9 80.0 80.1 80.2 80.4 81.1 84.3 88.0 88.1 88.2 88.5 89.2 92.8 96.0 96.1 96.3 96.5 97.3 101.2 104.1 104.1 104.3 104.6 105.4 109.6 112.1 112.2 112.3 112.6 113.5 118.1 120.1 120.2 120.3 120.6 121.7 126.5 128.1 128.2 128.3 128.7 129.8 134.9 Introduction Span ft 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 Chord Depth in 56 56 56 56 56 56 64 64 64 64 64 64 72 72 72 72 72 72 80 80 80 80 80 80 88 88 88 88 88 88 96 96 96 96 96 96 104 104 104 104 104 104 112 112 112 112 112 112 120 120 120 120 120 120 128 128 128 128 128 128 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 67 Introduction Scissor Joist (SPSC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 Chord Depth in 60 60 60 60 60 60 68 68 68 68 68 68 76 76 76 76 76 76 84 84 84 84 84 84 92 92 92 92 92 92 100 100 100 100 100 100 108 108 108 108 108 108 116 116 116 116 116 116 124 124 124 124 124 124 132 132 132 132 132 132 Ridge Depth in 60.0 60.1 60.2 60.3 60.8 63.2 68.0 68.1 68.2 68.4 68.9 71.7 76.0 76.1 76.2 76.4 77.0 80.1 84.0 84.1 84.2 84.5 85.2 88.5 92.0 92.1 92.2 92.5 93.3 97.0 100.0 100.1 100.3 100.5 101.4 105.4 108.1 108.1 108.3 108.6 109.5 113.8 116.1 116.2 116.3 116.6 117.6 122.3 124.0 124.1 124.2 124.4 125.0 127.8 132.0 132.1 132.3 132.5 133.0 136.1 Top Chord Pitch in/ft 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 Shape Depth in 83 98 113 135 181 303 91 106 121 143 189 312 99 114 129 151 197 320 107 122 137 159 205 329 115 130 145 167 213 337 123 138 153 176 221 345 131 146 161 184 229 354 139 154 169 192 238 362 139 154 169 184 215 308 147 162 177 192 223 316 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 39 39 39 39 44 45x>2 35 35 35 37 37 46x>2 34 35 35 35 36 44x>2 33 33 33 35 35 43x>2 35 35 35 36 36 49 41 41 41 42 43 51 42 42 43 43 45 68 50 51 51 51 58 71 53 59 59 59 59 71 53 60 60 60 62 72 47 47 47 47 47 49x>2 44 44 44 44 45 47x>2 40 40 40 40 45 47x>2 39 39 39 39 44 46x>2 39 39 39 39 44 50x>2 42 44 44 44 49 52 45 45 45 49 50 69 53 53 57 58 58 71 55 60 60 60 60 71 56 61 60 60 62 72 52 52 52 52 56 58x>2 48 48 48 48 48 55x>2 46 46 46 46 46 48x>2 45 45 45 46 46 52x>2 45 45 46 46 46 54x>2 49 49 49 49 50 56 50 50 50 50 50 69 58 58 58 58 58 71 60 60 60 60 60 72 61 61 61 61 62 73 56 56 56 56 60 62x>2 56 56 56 56 57 60x>2 50 50 50 50 50 56x>2 47 47 47 47 47 53x>2 47 47 47 47 47 55x>2 49 49 49 49 50 60x>2 50 50 50 50 54 69 58 58 58 62 62 72 60 60 61 64 64 72 61 61 61 61 66 73 63 63 63 63 64 70x>2 56 56 57 60 61 64x>2 57 57 57 58 58 64x>2 53 53 54 54 54 60x>2 50 53 53 53 54 60x>2 49 53 53 53 54 64x>2 54 54 54 54 54 69 62 62 62 62 66 72 64 64 64 64 68 73 65 65 65 65 70 74 71 71 71 71 71 77x>2 64 64 64 64 68 72x>2 58 58 62 62 62 68x>2 58 58 58 62 62 68x>2 55 55 55 55 59 65x>2 55 55 55 55 59 66x>2 54 54 58 58 58 70 62 66 65 66 66 73 68 68 68 68 68 73 65 69 69 68 70 74 74 74 79 79 80 82x>2 68 68 68 68 69 73x>2 65 65 65 66 69 72x>2 62 62 62 62 63 69x>2 63 63 63 63 64 70x>2 60 60 60 60 65 68x>2 59 59 59 59 63 71 66 66 69 70 70 78 68 68 72 72 72 73 69 69 69 72 74 74 83 83 83 84 84 95x>2 71 72 72 72 77 81x>2 69 69 69 69 70 78x>2 66 66 66 66 67 74x>2 64 67 67 67 68 76x>2 65 68 68 69 69 77x>2 64 65 65 65 65 77 70 70 70 70 70 78 72 72 72 72 73 78 73 73 73 73 74 79 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 92 92 92 92 93 103x>2 80 80 80 80 78 85x>2 72 73 73 73 74 82x>2 70 69 70 70 70 78x>2 68 68 68 68 69 77x>2 69 69 69 69 70 78x>2 69 69 69 69 65 86 70 70 70 70 75 87 73 73 73 73 73 78 73 73 73 73 75 79 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 68 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 750 800 Joist Self-Weight - Pounds per Linear Foot (plf) 100 100 100 100 101 104x>2 80 80 88 88 89 94x>2 78 78 78 78 79 91x>2 70 70 75 75 75 87x>2 72 72 72 72 77 90x>2 69 69 70 70 75 87x>2 69 69 70 74 74 86 71 71 75 75 76 87 74 74 79 79 79 86 74 74 74 74 81 88 101 101 101 101 113 116x>2 92 92 93 93 94 98x>2 81 81 82 82 90 94x>2 78 78 78 79 79 91x>2 77 77 77 77 77 90x>2 78 78 78 78 79 91x>2 75 75 75 75 76 86x>2 75 75 76 75 84 88 79 79 79 79 87 87 80 80 79 80 81 89 10 rows Scissor Joist (SPSC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 Joist Self-Weight - Pounds per Linear Foot (plf) 45 45 45 46 46 48x>2 43 43 43 44 44 47x>2 40 40 40 40 45 46x>2 39 39 39 39 40 46x>2 38 38 38 38 43 46x>2 43 43 43 47 48 49x>2 43 43 45 45 45 51 44 46 46 46 51 52 53 52 52 57 57 60 54 58 58 59 59 70 47 47 48 48 48 54x>2 46 46 46 47 47 53x>2 46 46 46 46 46 52x>2 46 46 46 46 46 53x>2 46 46 46 46 46 49x>2 48 48 48 48 48 53x>2 49 49 49 49 49 52 50 50 50 50 51 52 57 57 57 57 58 60 59 59 59 59 59 70 56 56 56 56 57 63x>2 56 56 56 56 57 59x>2 49 49 49 49 49 55x>2 48 48 48 49 49 55x>2 47 47 47 48 48 55x>2 48 48 48 48 52 54x>2 49 49 49 49 49 55 50 51 51 50 51 56 58 57 58 58 58 64 59 59 59 63 63 70 64 64 64 64 64 70x>2 56 60 60 60 61 64x>2 58 58 58 58 58 68x>2 58 58 58 58 59 68x>2 54 54 54 54 55 62x>2 53 53 54 54 54 63x>2 50 50 53 53 53 59 51 54 54 54 55 60 62 62 62 62 62 69 63 63 63 63 66 71 67 67 68 68 68 74x>2 64 64 64 68 69 72x>2 61 61 61 61 62 68x>2 58 58 62 62 63 69x>2 58 58 62 62 63 70x>2 55 59 59 59 60 65x>2 55 55 55 55 59 64 56 56 56 56 60 65 62 65 65 65 66 73 67 67 67 67 67 71 71 71 71 71 80 80x>2 68 68 68 68 69 73x>2 65 68 69 69 69 72x>2 63 63 63 63 67 70x>2 62 62 62 66 67 71x>2 64 64 64 67 68 70x>2 61 61 61 61 61 70 61 61 62 62 66 67 66 66 66 69 70 73 67 70 70 70 71 72 80 80 80 80 81 88x>2 72 76 76 77 77 81x>2 69 69 69 69 70 78x>2 70 70 70 70 71 79x>2 66 67 67 67 67 71x>2 68 68 68 68 68 75x>2 69 69 69 69 69 71 69 69 69 70 70 72 70 70 70 70 70 73 71 71 71 71 71 77 92 92 92 93 94 97x>2 80 80 80 80 81 93x>2 77 77 77 77 78 90x>2 73 73 73 74 79 83x>2 70 70 70 71 76 80x>2 68 68 69 69 74 76x>2 69 69 69 69 69 77 70 70 70 71 71 77 70 70 70 70 71 78 71 71 71 71 76 78 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 93 93 93 93 94 105x>2 92 89 89 89 90 98x>2 81 81 81 82 82 93x>2 79 79 79 79 80 92x>2 75 75 75 76 77 93x>2 77 77 77 77 77 89x>2 73 73 73 77 78 88 71 71 71 75 76 78 71 75 75 75 76 87 76 76 76 76 76 86 9 rows 101 101 101 101 102 117x>2 93 93 93 94 94 99x>2 89 89 89 90 90 94x>2 82 82 91 91 92 95x>2 79 80 80 88 88 93x>2 77 77 77 85 86 89x>2 78 78 78 78 78 89 79 79 79 79 79 90 76 76 76 76 85 88 76 76 84 84 84 86 112 112 112 113 113 118x>2 101 101 101 102 103 118x>2 94 94 94 94 95 99x>2 91 91 91 91 92 96x>2 91 91 91 92 92 97x>2 89 89 89 89 90 93x>2 79 78 86 86 87 92 79 79 87 87 88 90 88 88 88 88 88 93 85 85 85 85 85 86 SP-Series Tables Shape Depth in 90 107 123 148 197 330 96 113 129 154 203 336 102 119 135 160 209 342 108 125 141 166 215 349 114 131 147 172 221 355 120 137 153 178 227 361 118 135 151 167 200 300 124 141 157 173 206 306 130 147 163 179 212 313 136 153 169 185 218 319 SP-Series Design Top Chord Pitch in/ft 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 Special Profile Joists Ridge Depth in 66.0 66.1 66.2 66.4 66.9 69.6 72.0 72.1 72.2 72.4 73.0 75.9 78.0 78.1 78.2 78.4 79.1 82.2 84.0 84.1 84.2 84.5 85.2 88.5 90.0 90.1 90.2 90.5 91.2 94.9 96.0 96.1 96.3 96.5 97.3 101.2 102.0 102.1 102.2 102.4 102.8 105.1 108.0 108.1 108.2 108.4 108.8 111.3 114.0 114.1 114.2 114.4 114.9 117.5 120.0 120.1 120.2 120.4 120.9 123.7 Introduction Span ft 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 Chord Depth in 66 66 66 66 66 66 72 72 72 72 72 72 78 78 78 78 78 78 84 84 84 84 84 84 90 90 90 90 90 90 96 96 96 96 96 96 102 102 102 102 102 102 108 108 108 108 108 108 114 114 114 114 114 114 120 120 120 120 120 120 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 69 Introduction Scissor Joist (SPSC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 Chord Depth in 70 70 70 70 70 70 76 76 76 76 76 76 82 82 82 82 82 82 88 88 88 88 88 88 94 94 94 94 94 94 100 100 100 100 100 100 106 106 106 106 106 106 112 112 112 112 112 112 118 118 118 118 118 118 124 124 124 124 124 124 Ridge Depth in 70.0 70.1 70.2 70.4 71.0 73.8 76.0 76.1 76.2 76.4 77.0 80.1 82.0 82.1 82.2 82.3 82.6 84.5 88.0 88.1 88.2 88.3 88.7 90.7 94.0 94.1 94.2 94.3 94.7 96.9 100.0 100.1 100.2 100.3 100.8 103.1 106.0 106.1 106.2 106.4 106.8 109.3 112.0 112.1 112.2 112.4 112.9 115.4 118.0 118.1 118.2 118.4 118.9 121.6 124.0 124.1 124.2 124.4 125.0 127.8 Top Chord Pitch in/ft 0.375 0.625 0.875 1.250 2.000 4.000 0.375 0.625 0.875 1.250 2.000 4.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 Shape Depth in 96 114 131 158 211 354 102 120 137 164 217 360 100 117 135 152 188 295 106 123 141 158 194 301 112 129 147 164 200 307 118 135 153 170 206 313 124 141 159 176 212 319 130 147 165 182 218 325 136 153 171 188 224 332 142 159 177 194 230 338 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 48 48 48 48 48 54x>2 47 47 47 47 48 52x>2 46 46 46 46 46 47x>2 45 45 45 46 46 47x>2 45 45 45 45 46 48 48 48 48 48 48 49 50 50 50 50 50 51 58 58 58 58 58 60 59 59 59 59 59 73 59 59 59 59 60 74 56 56 56 56 57 62x>2 53 53 53 53 57 58x>2 49 49 49 49 48 53x>2 48 49 49 49 49 54x>2 48 48 48 48 48 52x>2 48 48 48 48 49 53 50 50 50 50 50 55 58 58 58 59 59 63 59 59 59 60 59 73 60 60 60 60 60 75 60 60 60 60 61x>2 67x>2 57 57 57 57 61 67x>2 58 58 58 58 58 62x>2 54 54 54 54 54 59x>2 51 51 55 55 55 58x>2 50 53 53 53 54 59x>2 54 54 54 54 55 59 62 62 62 62 62 67 60 60 60 63 64 74 64 64 64 64 64 75 67 67 68 68 68x>2 74x>2 65 65 65 65 69 71x>2 61 61 61 61 62 67x>2 62 62 62 63 63 68x>2 59 59 59 60 63 67x>2 55 55 55 59 59 64x>2 56 56 60 60 60 64 62 66 66 66 66 71 64 64 64 64 67 74 64 67 67 67 67 75 72 72 72 72 77x>2 80x>2 69 69 69 69 70 77x>2 69 69 69 69 69 71x>2 66 66 66 66 67 68x>2 64 64 64 64 68 68x>2 63 63 64 67 67 69x>2 65 65 69 69 65 66x>2 66 66 70 70 70 72 67 67 68 67 71 74 68 68 71 71 71 75 80 80 80 80 85 92x>2 72 73 77 78 78 80x>2 73 69 70 70 70 76x>2 70 70 70 71 71 72x>2 71 71 71 71 71 74x>2 68 68 68 68 68 70x>2 69 70 70 70 70 71 70 70 70 71 71 73 71 71 71 71 71 79 72 72 72 72 72 81 92 92 93 93 93x>2 97x>2 81 81 81 81 82 92x>2 77 77 78 78 78 80x>2 74 78 79 79 79 81x>2 71 71 71 71 72 77x>2 72 72 72 72 72 78x>2 70 70 70 70 75 76x>2 71 71 71 71 76 78 72 72 72 72 72 80 72 72 72 73 78 81 93 101 101 101 102 105x>2 93 93 94 94 95 97x>2 81 81 89 89 90 92x>2 79 79 79 79 80 90x>2 80 80 80 80 81 90x>2 77 77 77 77 77 87x>2 78 78 78 78 78 88 79 79 79 79 79 89 72 76 77 77 77 89 77 77 78 78 78 90 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 101 101 101 112 113 117x>2 94 94 94 95 95 98x>2 94 94 94 94 95 96x>2 90 90 91 91 91 94x>2 81 81 81 89 89 91x>2 80 80 80 88 89 91x>2 79 79 79 87 87 89x>2 79 79 79 87 88 90 80 80 80 80 89 93 78 78 86 86 86 91 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 70 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 750 800 Joist Self-Weight - Pounds per Linear Foot (plf) 112 112 113 113 114x>2 128x>2 102 102 102 102 114 117x>2 94 94 94 95 95 97x>2 96 96 96 96 97 99x>2 92 92 93 93 93 94x>2 89 89 89 89 89 92x>2 91 91 91 91 91 93x>2 92 92 91 92 92 94 89 89 89 89 90 95 89 89 89 89 89 96 123 123 123 124 124 129x>2 113 114 114 114 115 118x>2 102 102 113 114 114 116x>2 96 96 96 97 97 111x>2 97 97 97 97 98 106x>2 93 93 93 93 93 95x>2 92 92 92 92 92 94x>2 92 92 92 93 93 96 93 93 94 94 94 99 90 90 90 90 90 96 10 rows Scissor Joist (SPSC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 Joist Self-Weight - Pounds per Linear Foot (plf) 48 48 48 49 49 54x>2 48 48 48 48 48 53x>2 47 47 47 47 47 52x>2 48 48 48 48 48 53x>2 49 49 49 49 49 51x>2 50 50 50 50 50 54 58 58 58 59 59 63 59 59 59 59 59 72 61 61 61 61 61 73 61 61 61 61 62 74 57 57 57 57 61 62x>2 58 58 58 58 58 63x>2 54 54 54 54 54 59x>2 49 53 53 53 53 60x>2 51 51 54 54 54 60x>2 50 54 53 54 54 58x>2 59 62 62 63 63 67 59 60 60 63 63 73 61 61 65 65 65 74 62 62 62 65 65 74 65 64 65 68 68 69x>2 62 62 62 62 62 67x>2 62 62 62 62 62 67x>2 59 59 63 63 63 68x>2 56 56 56 60 60 66x>2 57 60 60 60 60 65x>2 63 66 66 66 67 71 63 63 63 67 67 73 65 65 68 68 68 74 66 66 66 69 69 75 71 71 71 72 72 74x>2 69 69 69 70 70 71x>2 69 69 69 69 70 71x>2 63 63 67 67 67 69x>2 65 65 65 68 69 70x>2 64 68 68 68 68 70x>2 66 70 70 70 71 72 67 67 67 71 71 74 69 69 72 72 72 75 69 69 69 73 73 76 80 80 80 80 77 82x>2 73 73 73 78 78 80x>2 70 70 70 70 70 76x>2 71 71 71 71 71 77x>2 69 69 69 69 69 71x>2 68 68 68 69 69 71x>2 70 70 70 71 71 72x>2 71 71 71 71 71 79 72 72 72 73 73 75 73 73 73 73 73 76 84 85 88 88 89 91x>2 81 82 82 82 82 92x>2 78 78 78 78 79 88x>2 71 71 71 76 76 82x>2 72 72 72 72 73 79x>2 72 72 72 72 78 79x>2 71 71 71 71 76 77x>2 71 71 72 72 72 80 73 73 73 73 73 80 73 73 73 73 74 81 93 93 93 93 94 96x>2 94 94 94 94 95 97x>2 90 90 90 90 91 92x>2 79 79 80 80 80 91x>2 80 81 81 81 81 92x>2 77 77 77 78 78 88x>2 79 79 79 79 80 89x>2 75 80 80 81 81 91 78 78 78 78 78 89 74 74 79 79 79 90 101 101 101 102 102 115x>2 95 95 95 95 96 97x>2 95 95 95 95 95 93x>2 92 92 92 92 92 95x>2 81 89 90 90 90 92x>2 89 89 89 89 90 92x>2 80 88 88 88 89 90x>2 81 81 81 81 89 92x>2 81 81 81 90 90 93 79 79 79 80 89 91 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 113 113 113 113 114 116x>2 103 103 103 103 115 117x>2 95 95 95 96 96 109x>2 96 96 96 97 97 100x>2 93 93 93 94 94 96x>2 90 90 90 90 90 93x>2 92 92 91 92 92 94x>2 93 93 93 93 93 96x>2 90 90 90 90 91 94 92 92 92 92 93 95 9 rows 113 113 113 114 124 127x>2 114 114 115 115 115 118x>2 114 115 115 115 115 117x>2 97 97 97 97 98 111x>2 98 98 98 98 99 101x>2 93 94 94 94 94 107x>2 96 96 96 94 94 107x>2 94 94 94 94 94 109x>2 95 95 95 96 96 99 93 93 93 93 94 96 124 124 124 125 125 127x>2 115 115 115 115 116 118x>2 115 115 115 116 116 118x>2 116 116 116 116 117 120x>2 99 99 99 110 111 113x>2 98 98 98 109 110 112x>2 96 96 96 97 108 110x>2 97 97 97 98 98 113x>2 96 96 96 96 97 110x>2 97 97 97 97 98 111 SP-Series Tables Shape Depth in 95 114 132 151 189 303 101 120 138 157 195 310 107 126 144 163 201 316 113 132 150 169 207 322 119 138 156 175 213 328 125 144 162 181 219 334 131 150 168 187 225 340 137 156 174 193 231 347 143 162 180 199 237 353 149 168 187 205 244 359 SP-Series Design Top Chord Pitch in/ft 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 0.250 0.500 0.750 1.000 1.500 3.000 Special Profile Joists Ridge Depth in 76.0 76.1 76.1 76.3 76.6 78.3 82.0 82.1 82.2 82.3 82.6 84.5 88.0 88.1 88.2 88.3 88.7 90.7 94.0 94.1 94.2 94.3 94.7 96.9 100.0 100.1 100.2 100.3 100.8 103.1 106.0 106.1 106.2 106.4 106.8 109.3 112.0 112.1 112.2 112.4 112.9 115.4 118.0 118.1 118.2 118.4 118.9 121.6 124.0 124.1 124.2 124.4 125.0 127.8 130.0 130.1 130.3 130.5 131.0 134.0 Introduction Span ft 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 Chord Depth in 76 76 76 76 76 76 82 82 82 82 82 82 88 88 88 88 88 88 94 94 94 94 94 94 100 100 100 100 100 100 106 106 106 106 106 106 112 112 112 112 112 112 118 118 118 118 118 118 124 124 124 124 124 124 130 130 130 130 130 130 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 71 Introduction Arch Joist (SPAC) Tables Special Profile Joists The following weight tables are representative of SP-Series joist design or constructability per NMBS. The SP-Series Arch designs for Arch Joists with parameters shown in the diagram joists in the following tables are designed assuming pinnedbelow. Note that the Arch Joists’ standard designs may include roller supports. If this design results in a predicted approximate extra bottom chord verticals. The maximum allowable Live Load horizontal deflection, бx, greater than two inches at the roller deflection is L/240 for a Live Load equal to 75 percent of the support, the approximate weight is flagged with the notation, ARCH JOIST (SPAC) WEIGHT TABLES Total Load listed in the table. The tables also give bridging бx>2. The specifying professional should do further investigation The following weight 904.5(d), tables arethe representative of SP-Series for Arch Joists withand parameters in the requirements per Section required seat depth for intojoist thedesigns actual horizontal deflection consider shown alternatives below. that Joists’self-weight standard designs include extra in bottom chord verticals. The maximum allowable thediagram given profile, asNote well as theArch estimated in poundsmayas explained HORIZONTAL REACTIONS on page 14. for the joist is L/240 for a Live Load equal to 75 percent of the Total Load listed in the table. The tables also give perdeflection linear foot. This catalog provides two design examples For further information, please contact your nearest NMBS bridging requirements per Section 904.5(d), the required seat depth for the given profile, as well as the estimated pounds for per reference and clarification design issues. The following representative or visit www.newmill.com. linear foot. This catalogonprovides two complete design examples for reference and clarification on design issues. The tables are not representative of any limits or constraints on following tables are not representative of any limits or constraints on design or constructability per NMBS. For further information, please contact your nearest NMBS representative or visit www.newmill.com. SP-Series Design ALL TABLES ARE BASED ON ASD ALL TABLES ARE BASED ON ASD Standard Specification SP-Series Tables ARCH JOIST (SPAC) 72 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 68 Arch Joist (SPAC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 10 10 10 10 11 13 9 9 10 10 11 12 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 12 9 9 9 9 10 12 9 9 8 8 9 12 9 9 9 9 9 12 9 9 9 9 9 11 10 10 10 10 11 13 9 9 10 10 11 12 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 8 9 12 9 9 9 9 9 12 9 9 9 9 10 11 10 10 10 10 11 13 9 9 10 10 11 12 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 9 12 9 9 9 9 9 12 9 9 9 9 10 11 Joist Self-Weight - Pounds per Linear Foot (plf) 10 10 10 10 11 13 9 9 9 10 11 12 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 8 8 8 8 9 11 9 9 9 9 9 11 9 9 9 9 9 11 10 10 10 10 11 13 9 9 9 10 11 12 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 8 8 8 8 9 11 9 9 9 9 9 12 9 9 9 9 9 11 10 10 10 10 11 13 9 9 9 10 11 12 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 9 8 8 8 9 12 9 9 9 9 9 12 9 9 9 9 9 11 10 10 10 10 11 13 9 9 9 10 11 12 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 12 9 9 9 9 10 12 9 8 8 8 9 12 9 9 9 9 9 12 9 9 9 9 9 11 10 10 10 10 11 13 9 9 9 10 11 12 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 12 9 9 9 9 10 12 9 8 8 8 9 12 9 9 9 9 9 12 9 9 9 9 9 11 10 10 10 10 11 13 9 9 9 10 11 12 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 12 9 9 9 9 10 12 9 8 8 8 9 12 9 9 9 9 9 12 9 9 9 9 9 11 10 10 10 10 11 13 9 9 9 10 11 12 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 12 9 9 9 9 10 12 9 8 8 8 9 12 9 9 9 9 9 12 9 9 9 9 9 11 10 10 10 10 11 13 9 9 10 10 11 12 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 12 9 9 9 9 10 12 9 8 8 8 9 12 9 9 9 9 9 12 9 9 9 9 9 11 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables Shape Depth in 13 14 15 18 25 40 17 18 19 22 29 44 21 22 23 26 33 48 25 26 27 30 37 52 29 30 31 34 41 56 33 34 35 38 45 60 37 38 39 42 49 64 41 42 43 46 53 68 45 46 47 50 57 72 49 50 51 54 61 76 SP-Series Design Bottom Chord Radius ft 59 39 29 19 10 5 59 39 29 19 9 5 59 39 29 19 9 5 58 38 28 18 9 4 58 38 28 18 8 4 58 38 28 18 8 4 57 37 27 17 8 3 57 37 27 17 7 3 57 37 27 17 7 3 56 36 26 16 7 2 Special Profile Joists Top Chord Radius ft 60 40 30 20 11 6 60 40 30 20 11 6 60 40 30 20 11 6 60 40 30 20 11 6 60 40 30 20 11 6 60 40 30 20 11 6 60 40 30 20 11 6 60 40 30 20 11 6 60 40 30 20 11 6 60 40 30 20 11 6 Introduction Span ft 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Chord Depth in 10 10 10 10 10 10 14 14 14 14 14 14 18 18 18 18 18 18 22 22 22 22 22 22 26 26 26 26 26 26 30 30 30 30 30 30 34 34 34 34 34 34 38 38 38 38 38 38 42 42 42 42 42 42 46 46 46 46 46 46 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 73 Introduction Arch Joist (SPAC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Chord Depth in 10 10 10 10 10 10 14 14 14 14 14 14 18 18 18 18 18 18 22 22 22 22 22 22 26 26 26 26 26 26 30 30 30 30 30 30 34 34 34 34 34 34 38 38 38 38 38 38 42 42 42 42 42 42 46 46 46 46 46 46 Top Chord Radius ft 120 80 60 41 21 13 120 80 60 41 21 13 120 80 60 41 21 13 120 80 60 41 21 13 120 80 60 41 21 13 120 80 60 41 21 13 120 80 60 41 21 13 120 80 60 41 21 13 120 80 60 41 21 13 120 80 60 41 21 13 Bottom Chord Radius ft 119 79 60 40 20 12 119 79 59 39 20 11 119 79 59 39 20 11 118 78 59 39 19 11 118 78 58 38 19 10 118 78 58 38 19 10 117 77 58 38 18 10 117 77 57 37 18 9 117 77 57 37 18 9 116 76 57 37 17 9 Shape Depth in 15 18 20 25 40 70 19 22 24 29 44 74 23 26 28 33 48 78 27 30 32 37 52 82 31 34 36 41 56 86 35 38 40 45 60 90 39 42 44 49 64 94 43 46 48 53 68 98 47 50 52 57 72 102 51 54 56 61 76 106 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 18 17 17 18 18 22 11 12 12 12 14 18 10 10 10 11 12 16 10 10 10 10 11 14 9 10 10 10 11 14 10 10 10 10 11 14 12 12 12 12 12 16 12 12 12 12 12 15 12 12 12 12 12 16 12 12 12 12 13 16 18 18 18 19 20 23 13 13 13 13 15 18 10 11 11 11 13 16 10 10 10 10 11 14 10 10 10 10 11 14 10 10 10 11 11 14 12 12 12 12 13 17 12 12 12 12 12 16 12 12 12 12 13 16 12 12 12 12 13 16 20 20 20 20 21 24 13 13 13 14 15 19 11 11 11 12 13 18 10 10 10 11 12 16 10 10 11 11 12 16 11 11 11 11 11 16 13 13 13 13 13 18 13 13 13 13 12 17 13 13 13 13 14 16 13 13 13 13 14 16 Joist Self-Weight - Pounds per Linear Foot (plf) 9 9 9 10 10 11 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 9 9 10 10 10 11 9 9 9 10 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 12 9 9 10 10 10 12 10 10 10 10 11 13 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 13 9 9 9 9 10 12 9 9 9 9 10 12 9 9 10 10 10 12 11 11 11 11 12 14 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 11 9 9 9 9 10 11 9 9 9 9 10 12 9 9 9 9 10 13 9 10 10 10 10 13 10 10 10 10 10 13 10 10 10 10 10 13 12 12 12 13 13 17 9 9 9 10 11 13 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 12 9 9 9 9 10 12 10 10 10 10 10 13 10 10 10 10 10 13 10 10 10 10 10 14 10 10 10 10 11 13 13 13 13 14 15 17 9 9 10 10 11 14 9 9 9 10 11 13 9 10 10 10 11 12 9 9 10 10 10 12 9 9 9 10 10 12 10 10 10 10 11 15 11 10 10 11 11 13 10 10 10 10 11 14 10 10 10 10 11 14 14 15 15 15 16 18 10 10 10 11 13 15 9 9 9 10 11 14 9 10 10 10 11 13 9 9 10 10 10 13 10 10 10 10 10 13 11 11 11 11 11 16 11 11 11 11 12 15 11 11 11 11 12 14 11 11 11 11 12 14 16 16 16 16 17 20 11 11 11 11 13 16 10 10 10 10 11 14 10 10 10 10 11 14 9 10 10 10 10 14 10 10 10 10 10 14 11 11 11 11 11 16 11 12 12 12 12 15 11 12 12 12 12 16 11 12 12 12 12 14 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 74 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 10 rows Arch Joist (SPAC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 21 21 21 21 24 28x>2 16 16 17 16 19 24 14 14 15 15 18 23 14 14 15 14 16 21 15 15 15 14 16 23 15 15 15 16 16 24 18 17 17 18 19 26 18 18 18 18 19 26 18 18 19 18 19 24 19 19 19 19 19 23 22 22 23 24 25 29x>2 16 17 17 19 20 24 16 16 16 16 19 24 14 15 15 15 17 24 15 15 15 15 17 23 15 15 15 16 17 24 19 19 19 19 21 28 19 19 19 18 21 26 19 19 19 19 20 26 20 20 20 19 19 25 24 24 25 25 28 31x>2 18 18 19 19 21 26 16 16 17 17 19 26 15 16 16 17 18 24 16 16 16 16 18 25 16 16 17 18 17 24 19 19 19 20 21 30 19 19 19 19 21 28 19 19 19 19 20 26 21 20 20 20 20 26 Joist Self-Weight - Pounds per Linear Foot (plf) 10 10 10 10 11 14 9 9 9 9 10 13 9 9 9 9 10 13 9 9 9 9 10 13 9 10 10 10 10 14 10 10 10 10 11 14 11 11 11 12 12 16 12 12 13 13 13 16 13 13 13 13 13 17 14 14 14 14 13 17 11 11 11 12 13 15x>2 9 9 9 10 11 14 9 9 9 10 11 14 9 9 10 10 10 14 10 10 10 10 11 14 10 10 11 11 11 14 12 12 12 12 13 18 12 12 13 13 13 17 13 13 13 13 15 17 14 14 14 14 14 18 12 13 13 13 15 17x>2 10 10 10 10 13 15 10 9 10 10 11 15 10 9 10 10 11 15 10 10 10 11 12 16 10 10 11 12 12 16 13 13 13 14 14 19 14 14 14 14 14 18 14 14 14 14 15 19 15 15 15 15 15 18 14 14 14 15 17 18x>2 11 11 11 11 13 17 10 10 11 11 13 17 10 10 10 10 12 16 11 11 11 11 13 17 11 11 11 12 13 17 14 14 14 14 15 22 14 14 14 14 16 20 14 14 14 14 15 20 15 15 15 15 15 19 15 15 16 17 17 21x>2 12 12 12 13 14 17 11 11 11 12 14 18 11 11 11 11 13 17 11 12 12 12 13 18 12 12 12 13 13 17 15 14 15 15 16 23 14 14 14 15 16 22 15 15 15 14 16 21 16 16 16 16 16 21 17 17 17 18 19 22x>2 13 13 13 13 16 19 12 12 12 13 15 19 11 11 11 12 14 18 12 12 12 12 14 19 12 12 13 14 14 18 16 16 15 16 17 24 16 15 15 15 16 23 16 15 15 15 16 22 17 17 17 17 17 22 18 18 18 19 20 24x>2 14 15 15 15 17 21 12 13 13 13 16 20 13 13 13 13 15 18 14 14 14 13 15 21 13 14 15 15 15 20 16 16 15 16 18 24 16 16 16 16 17 25 17 16 16 16 17 23 17 17 17 17 18 23 19 19 19 20 21 26x>2 15 15 16 16 18 22 13 14 14 14 16 22 13 13 13 13 16 20 14 14 14 14 16 21 14 14 15 16 16 21 17 17 16 16 18 26 17 17 17 17 18 25 18 17 17 17 19 23 18 18 18 18 19 23 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables Shape Depth in 23 27 31 39 61 106 29 33 37 45 67 112 35 39 43 51 73 118 41 45 49 57 79 124 47 51 55 63 85 130 53 57 61 69 91 136 59 63 67 75 97 142 65 69 73 81 103 148 71 75 79 87 109 154 77 81 85 93 115 160 SP-Series Design Bottom Chord Radius ft 179 119 89 60 31 17 178 119 89 59 30 17 178 118 88 59 30 16 177 118 88 58 29 16 177 117 87 58 29 15 176 117 87 57 28 15 176 116 86 57 28 14 175 116 86 56 27 14 175 115 85 56 27 13 174 115 85 55 26 13 Special Profile Joists Top Chord Radius ft 180 120 91 61 32 19 180 120 91 61 32 19 180 120 91 61 32 19 180 120 91 61 32 19 180 120 91 61 32 19 180 120 91 61 32 19 180 120 91 61 32 19 180 120 91 61 32 19 180 120 91 61 32 19 180 120 91 61 32 19 Introduction Span ft 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 Chord Depth in 16 16 16 16 16 16 22 22 22 22 22 22 28 28 28 28 28 28 34 34 34 34 34 34 40 40 40 40 40 40 46 46 46 46 46 46 52 52 52 52 52 52 58 58 58 58 58 58 64 64 64 64 64 64 70 70 70 70 70 70 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 75 Introduction Arch Joist (SPAC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 Chord Depth in 20 20 20 20 20 20 28 28 28 28 28 28 36 36 36 36 36 36 44 44 44 44 44 44 52 52 52 52 52 52 60 60 60 60 60 60 68 68 68 68 68 68 76 76 76 76 76 76 84 84 84 84 84 84 92 92 92 92 92 92 Top Chord Radius ft 240 161 121 81 43 25 240 161 121 81 43 25 240 161 121 81 43 25 240 161 121 81 43 25 240 161 121 81 43 25 240 161 121 81 43 25 240 161 121 81 43 25 240 161 121 81 43 25 240 161 121 81 43 25 240 161 121 81 43 25 Bottom Chord Radius ft 239 159 119 80 41 23 238 158 119 79 40 23 237 158 118 78 40 22 237 157 117 78 39 21 236 156 117 77 38 21 235 156 116 76 38 20 235 155 115 76 37 19 234 154 115 75 36 19 233 154 114 74 36 18 233 153 113 74 35 17 Shape Depth in 30 35 40 50 80 140 38 43 48 58 88 148 46 51 56 66 96 156 54 59 64 74 104 164 62 67 72 82 112 172 70 75 80 90 120 180 78 83 88 98 128 188 86 91 96 106 136 196 94 99 104 114 144 204 102 107 112 122 152 212 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 31 31 31 31 34 39x>2 22 23 23 24 27 34 20 20 20 21 24 31 20 19 19 20 24 30 19 21 21 21 24 32 22 23 22 23 24 31 25 26 26 27 28 44 26 26 26 27 28 37 27 27 26 26 28 35 28 28 28 27 28 35 33 33 33 33 36 41x>2 23 25 24 25 27 35 20 21 21 22 27 32 20 20 21 21 25 33 21 21 21 22 24 33 22 23 23 24 24 32 26 27 26 27 30 44 26 26 26 28 29 42 27 27 27 27 28 37 28 28 28 27 28 36 36 36 36 36 38 48x>2 25 25 25 27 30 37 22 22 22 23 28 34 21 22 22 22 27 33 21 21 21 22 27 33 23 24 24 26 26 34 27 27 28 29 31 45 28 27 27 29 30 43 28 27 27 27 29 43 28 28 28 28 30 38 Joist Self-Weight - Pounds per Linear Foot (plf) 13 13 14 14 15 19x>2 10 10 11 11 14 17 10 10 11 11 13 16 11 11 11 11 14 17 11 11 12 12 13 19 14 14 14 15 15 19 13 13 13 13 14 24 15 15 15 16 14 23 16 16 16 16 16 24 18 18 18 19 18 24 15 15 16 17 18 20x>2 12 12 12 13 16 19 11 11 11 12 15 18 12 12 12 12 14 20 12 12 12 12 15 20 14 14 14 15 16 21 14 13 14 14 19 27 18 17 17 17 15 26 18 18 18 18 19 24 19 20 20 19 20 26 17 17 17 18 20 23x>2 13 13 15 15 17 22 12 12 13 13 16 20 13 13 13 13 16 21 14 14 14 14 16 23 15 15 16 17 17 23 18 18 17 18 20 29 19 19 19 19 20 27 20 20 20 20 20 26 21 21 21 21 21 28 20 19 19 20 23 26x>2 16 16 15 16 19 24 15 14 16 16 17 23 15 15 15 15 17 23 14 14 14 15 18 23 15 15 16 17 18 25 20 20 19 20 23 32 19 19 19 21 22 30 21 21 20 20 21 28 21 21 21 21 21 30 21 21 21 22 25 29x>2 16 16 16 18 21 25 15 15 16 16 18 25 15 15 15 15 18 24 15 15 15 15 19 25 17 17 17 18 19 25 20 20 20 20 23 33 20 20 19 22 23 31 21 21 21 20 22 30 21 21 21 21 23 30 24 24 24 24 27 32x>2 18 18 18 19 22 28 16 16 16 16 20 25 15 15 15 16 19 25 16 16 16 16 20 27 18 18 19 19 21 27 20 20 20 21 24 34 22 22 21 22 23 32 22 22 22 22 24 32 23 23 23 22 24 32 27 27 27 27 28 35x>2 19 19 19 20 24 29 17 17 17 18 22 28 17 17 17 18 20 27 17 17 17 18 22 27 19 19 21 21 22 29 22 22 22 23 26 36 23 23 23 23 24 34 24 24 23 24 25 32 25 25 25 24 26 33 28 28 28 28 31 38x>2 21 21 21 22 25 31 18 18 19 19 23 28 18 18 18 18 23 29 18 18 19 19 23 29 20 21 22 22 23 30 23 23 23 25 26 37 24 24 25 25 26 35 25 25 25 25 27 34 26 26 26 26 28 34 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 76 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 10 rows Arch Joist (SPAC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 35 35 35 35 39 48x>2 27 27 28 29 34 46x>2 23 24 24 25 29 39 24 25 24 25 30 44 25 25 25 26 30 38 29 29 28 28 30 45 35 33 34 34 37 56 38 38 38 37 39 52 39 39 39 40 40 49 42 42 42 42 42 51 38 38 38 38 46 50x>2 29 31 29 31 36 47x>2 25 26 26 27 32 40 26 26 27 27 31 44 26 26 26 26 32 45 29 29 29 29 32 46 40 39 38 39 42 57 39 38 38 38 39 53 39 39 39 40 42 54 42 42 42 42 42 52 40 40 40 40 46 55x>2 31 31 31 32 38 48x>2 26 27 27 27 34 46 26 27 27 28 32 46 27 28 28 28 33 46 31 31 30 30 32 47 40 40 39 40 42 62 39 39 38 43 45 57 40 40 40 40 47 56 42 42 42 42 42 56 Joist Self-Weight - Pounds per Linear Foot (plf) 16 17 16 16 19 22x>2 15 13 14 14 17 22 14 14 15 15 16 22 13 13 13 16 16 23 16 15 15 15 19 24 15 15 16 16 16 25 17 18 18 17 18 33 20 20 20 22 22 34 22 22 22 24 25 34 29 29 29 29 27 36 18 18 18 19 21 26x>2 15 16 16 17 19 25 14 14 15 15 17 23 16 16 16 16 19 26 16 15 15 16 20 26 16 16 16 16 20 27 17 18 18 18 26 36 24 25 25 23 26 35 26 26 26 26 25 37 29 29 29 29 29 38 20 21 21 21 25 29x>2 16 17 17 18 22 28 15 15 16 16 20 26 16 16 16 17 21 28 17 17 17 17 22 28 20 20 19 19 23 29 25 24 24 25 28 38 26 26 26 28 29 38 27 27 27 27 32 38 30 30 30 30 31 40 22 24 23 25 28 32x>2 19 19 19 20 24 29 17 17 18 18 22 28 17 17 17 18 22 29 18 18 18 19 23 30 21 21 21 21 23 31 27 26 26 27 30 44 28 29 29 30 32 40 29 29 30 31 33 40 32 32 33 32 33 42 24 25 26 27 30 35x>2 20 20 20 22 26 31x>2 18 18 18 20 24 30 19 19 19 20 24 32 19 19 20 20 25 33 22 22 22 22 25 34 28 27 28 29 32 45 29 29 29 32 33 46 30 31 31 31 35 42 33 33 33 33 33 42 27 29 27 29 32 38x>2 22 23 22 24 27 33x>2 20 21 21 22 25 33 22 22 22 22 25 33 21 22 21 22 27 34 22 22 23 23 25 34 30 30 29 30 33 46 29 29 29 34 35 47 30 31 31 31 37 49 33 33 33 33 35 45 30 30 31 30 35 41x>2 23 24 24 25 29 36x>2 21 22 22 22 27 33 22 22 22 23 27 35 22 22 22 23 28 36 25 25 25 25 27 36 31 30 30 31 34 47 31 31 31 34 35 48 32 32 32 32 37 49 35 35 35 34 37 51 31 33 34 33 37 46x>2 25 25 27 27 31 40x>2 22 22 22 24 29 36 23 23 23 23 30 38 23 23 24 24 30 37 27 27 26 27 29 38 33 32 32 32 36 52 33 33 33 36 38 48 34 33 34 35 39 49 37 36 36 36 41 51 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables Shape Depth in 38 45 51 64 101 176 48 55 61 74 111 186 58 65 71 84 121 196 68 75 81 94 131 206 78 85 91 104 141 216 88 95 101 114 151 226 98 105 111 124 161 236 109 115 121 134 171 246 119 125 131 144 181 256 129 135 141 154 191 266 SP-Series Design Bottom Chord Radius ft 298 199 149 99 51 29 298 198 148 99 50 28 297 197 147 98 49 27 296 196 146 97 48 27 295 195 146 96 48 26 294 194 145 95 47 25 293 194 144 94 46 24 293 193 143 94 45 23 292 192 142 93 44 22 291 191 141 92 43 22 Special Profile Joists Top Chord Radius ft 301 201 151 102 53 31 301 201 151 102 53 31 301 201 151 102 53 31 301 201 151 102 53 31 301 201 151 102 53 31 301 201 151 102 53 31 301 201 151 102 53 31 301 201 151 102 53 31 301 201 151 102 53 31 301 201 151 102 53 31 Introduction Span ft 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 Chord Depth in 26 26 26 26 26 26 36 36 36 36 36 36 46 46 46 46 46 46 56 56 56 56 56 56 66 66 66 66 66 66 76 76 76 76 76 76 86 86 86 86 86 86 96 96 96 96 96 96 106 106 106 106 106 106 116 116 116 116 116 116 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 77 Introduction Arch Joist (SPAC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 Chord Depth in 30 30 30 30 30 30 40 40 40 40 40 40 50 50 50 50 50 50 60 60 60 60 60 60 70 70 70 70 70 70 80 80 80 80 80 80 90 90 90 90 90 90 100 100 100 100 100 100 110 110 110 110 110 110 120 120 120 120 120 120 Top Chord Radius ft 361 241 181 122 64 38 361 241 181 122 64 38 361 241 181 122 64 38 361 241 181 122 64 38 361 241 181 122 64 38 361 241 181 122 64 38 361 241 181 122 64 38 361 241 181 122 64 38 361 241 181 122 64 38 361 241 181 122 64 38 Bottom Chord Radius ft 358 238 179 119 61 35 357 238 178 119 60 34 356 237 177 118 60 33 356 236 176 117 59 33 355 235 175 116 58 32 354 234 175 115 57 31 353 233 174 114 56 30 352 233 173 114 55 29 351 232 172 113 55 28 351 231 171 112 54 28 Shape Depth in 45 52 60 75 120 210 55 62 70 85 130 220 65 72 80 95 140 230 75 82 90 105 150 240 85 92 100 115 160 250 95 103 110 125 170 260 105 113 120 135 180 270 115 123 130 145 190 280 125 133 140 155 200 290 135 143 150 165 210 300 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 49 49 49 49 54 59x>2 33 35 35 36 45 54x>2 31 31 32 33 38 48x>2 30 31 30 32 37 48 32 32 32 33 38 49 31 31 31 33 38 54 35 35 35 35 38 54 43 43 44 45 52 70 47 47 48 48 49 72 47 48 48 49 53 69 49 49 49 49 58 59x>2 36 36 36 38 46 59x>2 33 33 33 34 44 53x>2 32 32 33 34 43 53 33 33 33 34 39 54 33 33 34 35 44 54 37 37 37 38 44 59 46 47 48 49 52 76 50 51 52 52 54 72 48 48 48 53 54 70 53 53 53 53 59x>2 67x>2 38 39 39 44 47 59x>2 34 35 35 36 44 55x>2 33 33 34 36 45 53 34 34 33 34 44 55 35 36 36 36 45 60 43 42 43 43 44 61 47 48 48 50 57 78 51 51 52 53 54 72 51 51 51 53 59 72 Joist Self-Weight - Pounds per Linear Foot (plf) 20 20 20 21 23 28x>2 16 17 17 18 22 27x>2 16 16 16 17 21 26 16 16 17 18 22 28 17 17 18 19 23 28 17 18 18 18 24 32 22 22 22 22 25 33 22 22 23 23 25 48 25 25 25 27 27 43 30 31 31 31 32 45 22 23 23 25 27 31x>2 18 19 19 21 24 31x>2 17 18 18 20 23 28 18 18 18 20 24 30 19 19 19 21 24 32 21 21 21 21 26 34 25 24 24 24 27 36 24 24 24 25 26 50 26 26 28 28 28 49 31 33 33 32 34 53 25 26 26 27 30 35x>2 21 21 22 22 27 32x>2 19 20 20 21 25 33 19 20 20 21 26 33 21 21 21 22 26 34 22 22 23 23 28 37 25 25 25 25 29 37 24 24 24 25 37 51 29 29 29 29 30 50 33 36 36 37 38 53 28 29 29 30 34 38x>2 22 24 24 24 29 37x>2 21 22 23 23 27 35 22 23 23 23 27 35 23 23 23 24 28 36 23 24 24 25 30 39 27 27 28 28 30 39 34 34 35 36 39 55 30 30 30 30 40 56 38 38 38 39 40 53 31 32 32 33 37 41x>2 25 25 27 27 32 40x>2 23 23 23 25 30 36x>2 23 23 24 25 32 38 24 24 24 26 30 38 26 26 26 27 32 45 30 30 30 30 33 46 36 37 36 38 44 60 40 40 41 41 42 57 42 42 43 44 46 59 35 35 36 36 39 48x>2 28 28 28 29 35 47x>2 25 25 25 28 32 39x>2 25 25 25 27 32 45 25 25 26 27 32 45 28 28 28 29 32 46 31 31 31 31 34 47 41 41 42 43 45 66 45 45 45 47 46 62 43 43 43 44 51 61 38 38 38 39 46 50x>2 30 31 31 32 37 47x>2 27 28 28 28 35 46x>2 27 27 28 28 34 46 28 28 28 29 33 46 30 30 30 30 35 48 33 33 33 33 35 48 42 42 43 44 47 70 45 46 46 47 48 66 43 43 44 45 51 66 44 44 44 45 51 55x>2 32 32 33 34 39 48x>2 28 28 29 30 37 47x>2 29 29 30 30 37 48 29 30 30 31 35 47 30 30 31 31 38 49 33 34 33 33 37 49 42 42 43 44 48 70 46 46 47 48 49 68 43 43 44 48 52 69 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 78 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 10 rows Arch Joist (SPAC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 50 50 50 54 55x>2 72x>2 41 40 45 46 51 64x>2 37 37 39 39 47 64x>2 35 36 36 39 45 65 36 36 36 37 46 61 36 36 36 37 47 66 43 44 44 45 48 72 44 46 48 46 51 72 55 56 56 58 65 94 56 58 58 59 67 93 54 57 54 57 62x>2 75x>2 46 46 46 51 55 68x>2 40 40 39 45 51 68x>2 38 38 39 40 47 69 38 39 39 40 47 69 39 38 39 40 47 70 44 44 44 46 51 72 45 47 48 47 54 72 59 60 61 63 69 97 60 61 62 64 68 93 57 57 57 61 66x>2 76x>2 46 51 50 51 56 72x>2 45 46 46 47 55 68x>2 44 44 44 45 52 69 39 40 41 41 49 69 45 45 45 46 48 70 44 44 45 46 52 73 45 51 52 48 54 72 59 60 62 63 69 97 62 61 63 65 71 96 Joist Self-Weight - Pounds per Linear Foot (plf) 22 23 25 24 27 33x>2 20 19 20 21 25 32x>2 18 19 19 21 24 33 19 19 19 21 25 33 19 19 19 22 26 33 22 22 22 23 27 36 23 23 24 24 31 41 32 32 32 27 33 42 29 29 29 30 34 60 33 34 36 36 37 45 25 26 26 28 31 37x>2 21 23 23 25 28 34x>2 21 21 22 23 27 35x>2 21 21 23 23 27 36 22 22 22 24 29 37 24 24 25 26 29 38 27 27 28 29 34 49 33 35 35 32 36 49 32 32 32 32 34 64 35 36 37 37 38 62 29 30 30 30 35x>2 46x>2 25 25 26 27 32 39x>2 23 23 25 26 31 39x>2 23 23 24 25 32 39 24 24 24 26 31 39 25 25 26 27 32 42 30 30 30 30 35 50 36 36 36 34 37 51 32 32 32 33 37 70 37 39 39 39 38 66 32 33 33 34 38x>2 48x>2 27 27 28 30 35 46x>2 25 25 27 28 32 46x>2 25 25 25 28 32 46 26 26 26 28 33 46 28 28 28 29 34 49 31 32 32 33 38 51 36 36 36 36 40 52 34 34 34 34 38 74 39 39 39 39 40 71 36 35 35 37 44x>2 50x>2 30 31 31 32 38 47x>2 28 28 28 31 35 47x>2 27 27 28 30 34 47 28 28 28 29 36 48 29 29 29 30 35 50 33 34 34 34 39 57 38 38 38 36 42 57 35 35 35 36 40 74 40 40 40 41 42 76 38 38 38 45 46x>2 59x>2 32 32 34 35 44 49x>2 29 30 30 33 38 47x>2 29 29 30 31 37 48 30 30 31 31 39 49 31 31 32 33 37 50 35 35 35 37 45 57 40 39 40 41 47 58 37 37 38 38 57 79 41 41 41 43 59 76 45 45 45 49 50x>2 63x>2 35 35 37 38 45 55x>2 32 33 33 36 44 53x>2 31 32 31 32 43 54 33 33 33 34 41 53 33 33 34 34 40 57 37 37 38 39 46 62 44 44 46 46 48 63 50 51 52 54 60 82 52 53 54 55 59 81 49 49 49 49 54x>2 64x>2 37 37 38 40 47 63x>2 34 34 36 38 46 59x>2 32 33 33 36 45 56 34 34 34 34 46 55 35 35 35 36 46 61 42 42 44 44 47 67 44 45 47 46 49 68 54 56 56 57 64 94 56 57 58 59 62 81 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables Shape Depth in 53 62 71 89 141 246 63 72 81 99 151 256 73 82 91 109 161 266 83 92 101 119 171 276 93 102 111 129 181 286 104 112 121 139 191 296 114 122 131 149 201 306 124 132 141 159 211 316 134 142 151 169 221 326 144 152 161 179 231 336 SP-Series Design Bottom Chord Radius ft 418 278 208 139 71 41 417 277 208 138 71 40 416 276 207 138 70 39 415 276 206 137 69 38 414 275 205 136 68 37 414 274 204 135 67 37 413 273 203 134 66 36 412 272 203 133 66 35 411 271 202 133 65 34 410 271 201 132 64 33 Special Profile Joists Top Chord Radius ft 421 281 211 142 74 44 421 281 211 142 74 44 421 281 211 142 74 44 421 281 211 142 74 44 421 281 211 142 74 44 421 281 211 142 74 44 421 281 211 142 74 44 421 281 211 142 74 44 421 281 211 142 74 44 421 281 211 142 74 44 Introduction Span ft 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 Chord Depth in 36 36 36 36 36 36 46 46 46 46 46 46 56 56 56 56 56 56 66 66 66 66 66 66 76 76 76 76 76 76 86 86 86 86 86 86 96 96 96 96 96 96 106 106 106 106 106 106 116 116 116 116 116 116 126 126 126 126 126 126 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 79 Introduction Arch Joist (SPAC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 Chord Depth in 40 40 40 40 40 40 50 50 50 50 50 50 60 60 60 60 60 60 70 70 70 70 70 70 80 80 80 80 80 80 90 90 90 90 90 90 100 100 100 100 100 100 110 110 110 110 110 110 120 120 120 120 120 120 130 130 130 130 130 130 Top Chord Radius ft 481 321 242 163 85 50 481 321 242 163 85 50 481 321 242 163 85 50 481 321 242 163 85 50 481 321 242 163 85 50 481 321 242 163 85 50 481 321 242 163 85 50 481 321 242 163 85 50 481 321 242 163 85 50 641 385 276 194 123 67 Bottom Chord Radius ft 478 318 238 159 82 47 477 317 238 158 81 46 476 316 237 158 80 45 475 315 236 157 79 44 474 315 235 156 78 43 473 314 234 155 78 43 473 313 233 154 77 42 472 312 233 153 76 41 471 311 232 153 75 40 630 374 265 183 113 56 Shape Depth in 60 70 80 100 160 280 70 80 90 110 170 290 80 90 100 120 180 300 90 100 110 130 190 310 100 110 120 140 200 320 110 120 130 150 210 330 120 130 140 160 220 340 130 140 150 170 230 350 140 150 160 180 240 360 145 155 165 180 210 290 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 58 58 58 64 70x>2 81x>2 51 51 51 55 59 72x>2 46 46 47 47 59 73x>2 44 45 45 48 57 70x>2 45 46 47 46 57 70 46 46 47 47 54 71 44 46 48 49 57 73 46 45 46 47 60 76 56 56 57 62 64 83 52 52 52 53 54 92 65 65 65 65 70x>2 85x>2 51 55 55 55 67 76x>2 48 48 52 51 60 73x>2 46 46 47 50 62 71x>2 46 47 47 48 61 75 46 47 48 48 62 76 45 48 48 51 61 79 46 46 47 49 64 81 60 60 62 66 69 92 53 53 52 53 58 95 65 68 69 69 78x>2 99x>2 58 55 55 59 67 82x>2 52 52 52 55 64 82x>2 47 47 48 54 62 79x>2 47 47 48 49 65 79 48 48 48 49 62 77 50 51 52 58 65 82 51 51 51 54 64 81 61 62 66 70 73 95 70 72 73 73 78 95 Joist Self-Weight - Pounds per Linear Foot (plf) 26 26 27 27 32x>2 40x>2 23 23 24 25 30 36x>2 22 23 23 25 30 37x>2 22 23 23 25 30 37 25 25 24 26 31 39 25 25 25 27 31 41 26 26 27 31 37 44 32 32 31 31 38 52 34 34 34 36 37 56 39 39 39 37 38 41 30 30 32 32 35x>2 46x>2 26 27 27 27 32 41x>2 25 25 26 28 31 45x>2 24 26 26 28 33 46 26 26 26 29 33 46 27 28 28 30 34 47 31 31 31 33 38 51 33 33 32 35 38 54 36 36 36 38 47 58 41 41 41 40 40 45 33 35 35 36 43x>2 50x>2 28 30 30 32 38 47x>2 27 28 28 30 37 48x>2 27 28 29 31 35 48x>2 28 28 29 31 37 48 30 30 30 32 36 50 33 33 34 36 40 53 35 35 35 36 43 55 46 46 46 46 52 63 43 42 41 42 42 47 37 38 39 39 46x>2 59x>2 31 32 34 35 44 49x>2 30 31 32 33 43 48x>2 30 31 31 34 38 49x>2 31 31 32 33 43 54 32 32 33 34 40 55 34 35 36 37 44 58 36 36 36 37 49 60 47 47 52 52 52 67 43 43 41 42 44 48 45 45 45 45 50x>2 63x>2 35 35 36 38 45 55x>2 33 33 34 36 45 55x>2 32 33 34 37 46 55x>2 33 33 33 35 45 59 33 34 35 35 46 59 36 37 38 41 49 63 37 37 37 39 50 64 52 52 52 52 54 72 43 45 44 45 46 49 49 49 49 53 58x>2 64x>2 39 39 40 45 47 64x>2 36 37 37 39 46 64x>2 34 34 36 38 46 61x>2 35 36 36 38 46 61 36 36 36 37 47 65 38 39 40 44 51 65 39 39 40 41 50 70 52 52 52 54 56 78 47 47 46 52 52 80 50 50 53 57 58x>2 72x>2 40 45 46 46 55 65x>2 39 40 39 46 51 68x>2 36 37 39 41 48 70x>2 38 39 39 40 46 70 39 40 39 40 47 70 44 44 46 48 51 73 44 45 45 46 51 75 52 52 52 58 59 78 52 51 51 52 53 80 57 54 57 57 62x>2 75x>2 46 46 51 51 55 72x>2 45 46 46 47 56 69x>2 39 40 40 46 53 70x>2 44 44 45 46 51 70 44 46 45 46 52 71 44 45 47 48 56 73 46 45 45 47 56 76 56 56 56 62 63 83 52 52 52 52 54 89 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 80 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 10 rows Arch Joist (SPAC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 69 72 69 73 83x>2 100x>2 59 63 63 63 71x>2 95x>2 56 56 57 60 68 92x>2 50 50 54 57 66 83x>2 48 49 49 54 66 81x>2 54 53 54 55 63 79 54 55 55 56 65 79 59 60 60 61 67 77 59 59 60 61 64 84 63 63 63 65 66 80 73 73 73 78 87x>2 100x>2 63 63 66 70 79 100x>2 57 57 60 64 68 96x>2 57 58 58 58 69 93x>2 53 55 54 58 66 94x>2 54 55 56 60 67 83 54 59 60 61 69 79 59 60 61 63 71 81 63 64 65 65 67 87 63 63 65 66 66 85 Joist Self-Weight - Pounds per Linear Foot (plf) 28 30 30 32 36x>2 47x>2 27 28 28 29 35 46x>2 25 26 27 28 32 46x>2 24 26 26 28 33 46x>2 26 27 27 29 34 47 30 30 31 32 36 49 33 32 33 34 37 48 34 34 34 35 37 50 37 37 38 38 38 55 39 43 43 43 44 51 33 34 35 35 43x>2 49x>2 30 30 30 33 38 48x>2 28 29 30 31 37 48x>2 28 29 29 31 35 48x>2 29 29 29 31 37 50 33 34 34 36 37 49 35 35 35 37 39 50 36 36 37 37 44 53 37 37 38 38 44 56 44 44 44 44 44 58 36 38 38 39 46x>2 59x>2 33 33 35 36 44 55x>2 31 33 33 35 44 54x>2 32 32 33 34 45 54x>2 31 32 34 34 44 55 35 35 36 37 41 51 37 37 37 39 43 52 38 39 39 39 47 55 42 42 42 43 46 57 46 46 46 46 49 59 44 45 45 50 51x>2 64x>2 36 37 38 43 47 64x>2 34 35 35 38 45 56x>2 34 34 34 37 46 55x>2 34 34 34 36 46 57 37 38 38 39 47 60 38 39 40 40 49 56 44 44 44 45 53 60 48 48 49 50 51 62 48 48 48 49 54 63 50 50 50 50 55x>2 68x>2 40 45 45 47 55 68x>2 37 39 39 44 47 65x>2 37 37 37 40 48 66x>2 36 37 37 39 47 63x>2 40 40 41 42 47 64 41 42 42 43 50 61 49 49 49 51 53 65 49 49 50 50 52 70 53 52 53 54 55 66 50 50 54 54 62x>2 72x>2 46 47 47 51 56 72x>2 40 45 45 46 56 69x>2 40 40 40 46 53 70x>2 38 39 39 45 52 71x>2 45 45 46 47 48 67 47 47 48 49 51 66 49 49 50 52 54 69 49 49 50 51 54 74 53 53 55 55 56 73 54 55 58 62 67x>2 81x>2 51 51 51 55 60x>2 73x>2 46 47 46 48 60 73x>2 45 46 46 48 58 70x>2 44 45 45 47 54 71x>2 46 47 47 48 49 67 48 48 49 50 51 70 49 49 51 53 63 73 49 50 51 52 58 74 54 55 55 55 57 77 58 62 62 62 70x>2 85x>2 52 55 55 56 67x>2 82x>2 48 48 48 56 61 79x>2 47 48 48 49 62 71x>2 46 47 47 48 62 71x>2 47 48 49 49 55 71 48 49 50 51 56 71 52 53 54 57 63 73 54 55 56 57 58 77 58 58 59 60 62 77 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 65 62 65 69 75x>2 95x>2 56 56 56 63 67x>2 86x>2 52 52 56 56 65 83x>2 48 50 49 57 65 79x>2 47 47 48 50 66 80x>2 49 50 49 50 59 74 53 54 55 55 58 71 54 55 56 57 67 73 55 55 56 58 63 77 59 59 59 61 62 77 9 rows SP-Series Tables Shape Depth in 68 80 91 114 181 316 78 90 101 124 191 326 88 100 111 134 201 336 98 110 121 144 211 346 109 120 131 154 221 356 113 124 135 152 186 276 123 134 145 162 196 286 133 144 155 172 206 296 143 154 165 182 216 306 153 164 175 192 226 316 SP-Series Design Bottom Chord Radius ft 537 358 268 179 92 52 536 357 267 178 91 52 535 356 266 177 90 51 535 355 266 176 89 50 534 354 265 176 88 49 713 425 302 210 131 67 712 424 301 210 130 66 711 424 301 209 129 65 710 423 300 208 128 65 709 422 299 207 127 64 Special Profile Joists Top Chord Radius ft 541 361 272 183 96 56 541 361 272 183 96 56 541 361 272 183 96 56 541 361 272 183 96 56 541 361 272 183 96 56 721 433 310 218 139 75 721 433 310 218 139 75 721 433 310 218 139 75 721 433 310 218 139 75 721 433 310 218 139 75 Introduction Span ft 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 Chord Depth in 46 46 46 46 46 46 56 56 56 56 56 56 66 66 66 66 66 66 76 76 76 76 76 76 86 86 86 86 86 86 96 96 96 96 96 96 106 106 106 106 106 106 116 116 116 116 116 116 126 126 126 126 126 126 136 136 136 136 136 136 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 81 Introduction Arch Joist (SPAC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Chord Depth in 50 50 50 50 50 50 58 58 58 58 58 58 66 66 66 66 66 66 74 74 74 74 74 74 82 82 82 82 82 82 90 90 90 90 90 90 98 98 98 98 98 98 106 106 106 106 106 106 114 114 114 114 114 114 122 122 122 122 122 122 Top Chord Radius ft 601 402 302 203 106 63 601 402 302 203 106 63 801 481 345 243 154 83 801 481 345 243 154 83 801 481 345 243 154 83 801 481 345 243 154 83 801 481 345 243 154 83 801 481 345 243 154 83 801 481 345 243 154 83 801 481 345 243 154 83 Bottom Chord Radius ft 597 397 298 199 102 58 596 397 297 198 101 58 795 476 339 237 149 78 795 475 339 236 148 77 794 474 338 236 147 77 793 474 337 235 147 76 793 473 337 234 146 75 792 472 336 234 145 75 791 472 335 233 145 74 791 471 335 232 144 73 Shape Depth in 75 87 100 125 200 350 83 95 108 133 208 358 85 97 110 129 166 266 93 105 118 137 174 274 101 113 126 145 182 282 109 121 134 153 190 290 117 129 142 161 198 298 125 137 150 169 206 306 133 145 158 177 214 314 141 153 166 185 222 322 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 73 73 73 78 88x>2 100x>2 63 63 70 70 80x>2 96x>2 57 64 64 64 68 82x>2 57 58 58 61 68 79x>2 58 58 59 62 66 79 54 55 58 62 66 80 54 55 57 64 68 78 55 56 57 65 68 88 62 62 63 64 70 80 61 61 64 67 75 92 78 78 78 78 92x>2 121x>2 70 70 70 70 89x>2 101x>2 64 64 64 68 71 90x>2 61 62 62 68 69 91x>2 62 62 62 62 69 88 59 62 62 62 66 89 59 61 63 64 68 90 59 61 61 65 69 91 62 63 64 68 71 91 65 66 71 71 75 96 82 82 90 91 93x>2 121x>2 71 74 78 78 93x>2 114x>2 68 71 71 71 79 91x>2 62 65 69 69 72 91x>2 63 63 63 69 70 92 63 63 63 66 70 92 60 64 65 68 71 90 62 61 65 69 72 92 67 68 72 72 71 95 65 67 71 74 75 99 Joist Self-Weight - Pounds per Linear Foot (plf) 32 33 34 35 43x>2 49x>2 30 30 31 33 38x>2 48x>2 29 29 30 32 35 44x>2 28 29 31 32 33 45 29 29 31 32 33 45 30 30 32 34 34 46 32 33 34 36 39 48 35 35 35 36 39 50 33 33 33 34 44 51 34 37 37 37 46 55 36 38 38 44 47x>2 59x>2 34 36 36 37 45x>2 55x>2 33 34 34 35 38 46x>2 31 32 33 35 38 47x>2 31 33 34 35 39 47 32 34 34 34 38 49 35 36 37 38 41 51 36 36 37 38 42 57 36 36 36 44 46 57 47 47 47 47 53 61 45 45 45 46 55x>2 64x>2 38 38 38 44 48x>2 64x>2 37 37 37 39 44 53x>2 35 36 36 39 45 52x>2 35 35 37 39 45 53 34 34 37 38 45 54 37 37 39 41 47 55 38 39 39 42 49 61 42 43 44 46 52 60 48 48 48 53 54 65 50 50 50 54 59x>2 72x>2 45 46 46 47 56x>2 72x>2 40 40 45 46 48 61x>2 39 40 40 45 47 62x>2 38 38 40 45 46 58 38 38 40 45 46 59 40 42 42 47 50 61 41 41 42 48 50 67 49 50 51 52 54 67 53 53 53 53 57 71 54 54 54 58 63x>2 72x>2 47 51 51 55 60x>2 72x>2 46 46 48 48 56 65x>2 45 45 46 47 52 66x>2 46 45 46 46 48 66 45 45 46 47 48 68 46 48 47 49 50 69 47 48 48 49 50 71 50 51 52 53 54 71 53 53 53 53 60 75 58 58 61 62 70x>2 81x>2 51 55 55 55 67x>2 82x>2 48 48 52 52 56 69x>2 47 47 49 49 57 66x>2 47 47 48 48 57 67 47 47 48 48 54 68 48 49 49 50 55 69 48 48 49 51 55 71 51 52 53 54 59 72 54 54 54 56 62 75 62 62 62 69 75x>2 94x>2 55 56 56 62 68x>2 82x>2 52 53 56 56 60 70x>2 49 49 53 57 61 70x>2 48 49 50 54 61 71 48 48 49 53 62 69 49 50 50 55 60 70 50 49 51 52 61 71 56 57 58 58 64 72 58 58 58 64 67 75 72 72 69 70 83x>2 95x>2 63 63 63 70 76x>2 95x>2 57 57 57 60 67 78x>2 57 57 57 57 64 75x>2 54 54 58 58 62 76 53 53 55 55 62 77 53 54 55 56 64 78 53 54 55 57 65 79 57 58 58 59 68 80 61 61 62 67 75 84 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 82 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 10 rows Arch Joist (SPAC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 78 78 91 83 91x>2 114x>2 71 71 71 79 79 95x>2 69 69 72 72 80 91x>2 62 65 69 69 77 92x>2 63 63 66 70 70 92x>2 63 63 67 67 70 93 61 64 69 69 72 94 68 71 70 70 73 96 67 69 72 72 76 99 68 69 71 74 74 100 83 83 91 98 92x>2 115x>2 79 79 79 79 88 107x>2 72 72 72 77 81 96x>2 69 69 69 72 77 92x>2 67 70 70 70 78 92x>2 67 68 68 70 78 94 68 68 69 69 77 94 71 71 70 70 82 97 69 73 73 73 81 99 70 71 75 75 78 100 99 91 99 99 100x>2 115x>2 80 84 80 92 92 115x>2 73 73 81 81 89 108x>2 70 73 73 77 89 108x>2 71 71 70 74 81 104x>2 68 68 71 71 79 94x>2 69 70 70 73 81 106 71 72 71 74 85 109 72 73 73 73 84 111 72 75 75 75 83 100 Joist Self-Weight - Pounds per Linear Foot (plf) 35 35 36 38 43 48x>2 33 35 35 36 43 47x>2 33 33 35 36 39 47x>2 33 33 34 35 38 47x>2 32 34 34 36 39 48 35 36 37 38 45 50 36 36 37 39 47 56 33 34 36 41 50 57 37 36 37 44 51 62 39 39 39 45 47 58 40 44 44 46 46 56x>2 38 39 39 44 45 57x>2 36 38 39 41 45 54x>2 36 37 38 40 46 53x>2 35 37 38 40 46 53 36 38 41 42 47 56 38 39 41 47 49 61 42 42 44 48 51 62 42 43 45 51 54 71 44 45 46 48 54 67 46 50 50 51 55 64x>2 45 45 45 47 55 61x>2 41 45 45 47 48 62x>2 40 40 45 46 47 62x>2 40 40 46 47 47 63 41 42 46 47 48 69 41 42 48 48 50 66 44 45 49 49 52 68 50 50 51 52 55 74 51 52 52 54 55 76 51 55 55 55 59 71x>2 48 52 51 55 55 68x>2 47 47 48 49 57 67x>2 46 46 47 47 53 66x>2 46 47 47 48 54 67 47 47 47 48 53 69 47 48 49 50 55 70 49 50 52 52 58 72 51 52 52 54 60 74 52 53 54 55 60 76 55 58 62 62 66 80x>2 55 56 56 56 60 69x>2 49 52 56 57 61 70x>2 48 48 49 53 61 67x>2 48 48 49 54 62 68x>2 48 48 48 53 58 69 49 49 50 54 60 71 51 52 53 56 65 72 52 53 53 58 65 78 53 54 55 56 61 76 62 62 63 69 70 81x>2 56 56 59 63 67 77x>2 57 57 57 61 68 78x>2 54 57 57 57 65 75x>2 49 51 55 58 62 76x>2 49 50 53 55 66 78 53 54 55 57 68 79 56 57 57 57 69 77 57 58 58 59 72 86 58 59 60 60 66 84 70 70 73 70 78 90x>2 63 63 63 67 70 90x>2 58 58 61 65 68 87x>2 57 58 62 61 68 87x>2 55 58 59 62 66 80x>2 54 55 55 62 66 81 54 55 57 64 68 87 57 58 58 66 70 89 61 62 63 64 72 98 60 61 60 65 73 84 73 73 82 78 79x>2 95x>2 64 70 70 70 75 90x>2 65 65 65 69 72 91x>2 61 62 62 69 69 91x>2 59 59 62 66 70 92x>2 59 63 63 66 67 90 59 61 64 68 68 90 63 64 64 70 73 92 62 63 65 72 73 98 64 64 65 67 74 96 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables Shape Depth in 77 90 104 125 166 276 85 98 112 133 174 284 93 106 120 141 182 292 101 114 128 149 190 300 109 122 136 157 198 308 117 130 144 165 206 316 125 138 152 173 214 324 133 146 160 181 222 332 141 154 168 189 230 340 149 162 176 197 238 348 SP-Series Design Bottom Chord Radius ft 876 525 374 262 165 87 876 524 374 262 164 86 875 523 373 261 164 86 874 523 372 260 163 85 874 522 372 260 162 84 873 521 371 259 162 84 872 521 370 258 161 83 872 520 370 258 160 82 871 519 369 257 160 82 870 519 368 256 159 81 Special Profile Joists Top Chord Radius ft 881 529 379 267 170 92 881 529 379 267 170 92 881 529 379 267 170 92 881 529 379 267 170 92 881 529 379 267 170 92 881 529 379 267 170 92 881 529 379 267 170 92 881 529 379 267 170 92 881 529 379 267 170 92 881 529 379 267 170 92 Introduction Span ft 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 Chord Depth in 56 56 56 56 56 56 64 64 64 64 64 64 72 72 72 72 72 72 80 80 80 80 80 80 88 88 88 88 88 88 96 96 96 96 96 96 104 104 104 104 104 104 112 112 112 112 112 112 120 120 120 120 120 120 128 128 128 128 128 128 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 83 Introduction Arch Joist (SPAC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 Chord Depth in 60 60 60 60 60 60 68 68 68 68 68 68 76 76 76 76 76 76 84 84 84 84 84 84 92 92 92 92 92 92 100 100 100 100 100 100 108 108 108 108 108 108 116 116 116 116 116 116 124 124 124 124 124 124 132 132 132 132 132 132 Top Chord Radius ft 961 578 414 291 185 100 961 578 414 291 185 100 961 578 414 291 185 100 961 578 414 291 185 100 961 578 414 291 185 100 961 578 414 291 185 100 961 578 414 291 185 100 961 578 414 291 185 100 1441 721 482 363 244 128 1441 721 482 363 244 128 Bottom Chord Radius ft 956 573 409 286 180 95 955 572 408 285 179 94 955 571 407 285 179 94 954 571 407 284 178 93 953 570 406 283 177 92 953 569 405 283 177 92 952 569 405 282 176 91 951 568 404 281 175 90 1430 711 472 352 233 117 1430 710 471 352 233 117 Shape Depth in 83 98 113 135 180 300 91 106 121 143 188 308 99 114 129 151 196 316 107 122 137 159 204 324 115 130 145 167 212 332 123 138 153 175 220 340 131 146 161 183 228 348 139 154 169 191 236 356 139 154 169 184 214 304 147 162 177 192 222 312 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 99 91 91 91 100x>2 115x>2 80 80 80 88 92 116x>2 72 73 77 80 93 108x>2 69 69 73 77 82 97x>2 71 71 71 71 79 93x>2 69 69 72 73 81 96x>2 69 70 70 73 81 97x>2 72 73 73 73 81 98 70 73 73 73 76 95 70 71 75 74 75 97 99 99 99 99 111x>2 116x>2 80 92 99 92 93 116x>2 80 81 81 81 94 116x>2 73 73 78 81 91 109x>2 72 72 75 79 90 109x>2 73 72 73 81 92 108x>2 69 70 73 78 89 109x>2 72 73 73 81 93 110 72 74 74 74 84 98 72 75 75 75 78 97 100 100 110 110 112x>2 138x>2 92 100 99 100 111 117x>2 85 81 90 93 94 116x>2 79 81 81 89 95 117x>2 80 80 80 83 91 110x>2 73 73 81 81 93 112x>2 74 74 74 81 93 113x>2 77 78 81 81 96 110 79 79 82 82 86 98 75 76 75 75 83 100 Joist Self-Weight - Pounds per Linear Foot (plf) 39 40 45 44 47x>2 57x>2 37 38 40 44 45 53x>2 36 37 38 39 46 52x>2 35 36 37 39 46 54x>2 35 38 38 40 47 53x>2 37 37 40 42 49 56 38 40 40 42 48 57 38 43 46 50 53 64 38 39 48 49 54 61 43 45 51 51 57 60 47 47 51 51 55x>2 64x>2 46 46 46 47 51 62x>2 41 41 45 47 47 62x>2 40 40 45 46 48 63x>2 39 41 46 47 48 60x>2 40 42 48 49 50 62 41 42 48 48 51 68 45 46 51 52 55 69 50 50 54 54 54 65 53 53 53 57 58 65 51 55 55 55 59x>2 68x>2 48 52 52 56 60 69x>2 47 47 49 49 57 66x>2 46 46 48 48 54 67x>2 47 47 48 48 55 68x>2 47 48 50 50 55 70 48 48 50 51 56 72 51 52 52 54 59 73 55 55 55 55 55 71 58 58 58 58 58 69 55 59 62 62 66x>2 77x>2 56 56 56 60 67 75x>2 49 52 56 57 61 70x>2 49 50 50 57 62 71x>2 49 50 50 55 63 68x>2 50 50 51 55 65 71x>2 49 49 51 55 61 72 53 54 55 59 65 73 55 55 55 55 61 75 58 58 58 58 63 77 63 63 66 69 70x>2 90x>2 56 60 63 63 67 78x>2 57 57 57 61 68 79x>2 50 57 58 58 66 76x>2 51 55 55 59 66 77x>2 51 51 57 60 68 79x>2 50 51 56 57 69 80 58 59 59 63 72 81 59 59 59 60 69 76 62 62 62 62 65 77 70 70 70 73 78x>2 90x>2 64 64 67 70 75 95x>2 58 61 64 65 69 87x>2 58 58 62 61 70 80x>2 59 59 63 63 67 89x>2 57 60 61 64 68 91x>2 56 57 61 65 69 92 59 60 65 69 73 90 59 59 60 65 72 81 62 62 62 63 71 78 74 78 78 78 87x>2 95x>2 70 74 71 71 79 95x>2 65 65 68 69 77 91x>2 62 62 69 69 73 92x>2 63 63 63 67 70 92x>2 63 64 64 68 72 94x>2 61 65 65 69 70 93 64 65 68 72 73 94 62 63 65 72 72 92 66 66 67 68 74 86 83 83 83 91 92x>2 115x>2 75 76 79 79 88 107x>2 69 72 72 72 81 92x>2 66 69 69 69 78 93x>2 64 67 70 70 78 93x>2 65 65 68 72 73 95x>2 65 65 69 69 78 96 69 72 73 73 81 97 68 69 72 73 76 95 69 69 70 74 74 94 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 84 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 10 rows Arch Joist (SPAC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 100 100 100 100 112x>2 116x>2 92 92 93 93 112x>2 117x>2 81 81 89 93 94 117x>2 81 81 82 90 94 117x>2 79 79 82 90 91 117x>2 77 80 80 91 91 110x>2 73 74 74 81 82 94x>2 74 74 74 82 82 96 72 75 76 80 92 97 77 78 81 81 92 109 100 100 111 112 122x>2 138x>2 93 93 100 100 112x>2 129x>2 93 93 94 93 113 117x>2 82 82 94 94 95 117x>2 82 82 90 90 95 118x>2 80 81 91 91 96 117x>2 78 82 82 82 93 110x>2 79 79 82 83 94 111 80 81 81 84 95 112 77 81 81 84 93 109 112 112 112 112 123x>2 139x>2 101 101 112 112 113x>2 140x>2 94 94 94 101 113 118x>2 94 94 94 95 113 129x>2 91 91 91 95 106 129x>2 92 92 92 92 107 130x>2 83 82 85 93 93 111x>2 83 82 83 93 95 112 81 84 85 93 96 113 88 89 92 92 96 113 Joist Self-Weight - Pounds per Linear Foot (plf) 45 45 47 47 55 61x>2 45 45 46 46 48 62x>2 40 40 45 46 47 59x>2 40 41 45 46 48 59x>2 40 40 45 46 47 59x>2 42 42 47 48 49 64x>2 40 41 43 48 50 56 40 43 43 49 50 57 44 45 50 50 53 60 45 50 51 51 52 63 51 51 55 55 59x>2 69x>2 48 48 48 56 60 66x>2 47 47 48 49 57 67x>2 46 47 48 48 53 67x>2 46 47 47 48 54 67x>2 47 47 48 49 55 69x>2 48 49 50 51 51 62 48 48 50 50 51 63 50 51 51 53 54 72 51 51 52 54 59 69 56 56 56 60 67x>2 78x>2 56 56 56 60 64 75x>2 49 52 56 57 61 71x>2 50 50 53 57 61 71x>2 49 49 54 54 62 72x>2 49 50 53 55 63 74x>2 50 51 51 52 57 70 50 51 51 52 58 70 52 53 54 58 59 72 53 54 54 58 63 73 63 63 63 67 71x>2 90x>2 60 60 63 67 68 79x>2 57 57 57 61 68 79x>2 58 58 58 61 65 76x>2 54 58 58 62 66 77x>2 55 55 59 63 67 77x>2 51 52 57 57 65 70 51 52 57 58 65 70 57 58 59 63 68 72 58 59 59 64 72 78 70 70 71 71 79x>2 90x>2 64 67 67 71 76 91x>2 62 64 65 68 69 91x>2 58 62 62 69 69 88x>2 59 62 62 65 69 89x>2 59 63 63 67 70 89x>2 57 58 64 65 69 78 57 57 65 65 69 78 59 59 64 68 72 81 62 64 65 69 72 82 71 79 78 79 87x>2 95x>2 71 71 71 76 88 96x>2 69 69 69 72 77 92x>2 65 69 69 69 77 92x>2 62 66 69 69 77 93x>2 64 67 67 70 76 93x>2 65 65 66 69 73 90 65 66 66 69 70 90 64 67 72 72 72 93 63 65 72 73 73 94 79 79 79 92 92x>2 115x>2 76 79 80 80 88x>2 108x>2 72 72 72 77 80 97x>2 70 73 73 73 81 93x>2 70 70 70 73 78 93x>2 68 71 71 71 79 93x>2 66 69 69 73 73 94 66 70 70 73 74 94 71 71 72 72 75 96 68 72 73 73 81 97 92 92 92 92 100x>2 115x>2 80 80 88 92 93x>2 116x>2 77 80 80 80 89 109x>2 73 73 78 81 90 109x>2 71 74 78 78 90 109x>2 72 72 75 79 91 110x>2 70 73 73 73 81 94 71 71 74 74 82 95 72 72 72 75 80 96 72 72 73 76 81 98 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables Shape Depth in 90 107 123 147 196 326 96 113 129 153 202 332 102 119 135 159 208 338 108 125 141 165 214 344 114 131 147 171 220 350 120 137 153 177 226 356 118 135 151 167 200 297 124 141 157 173 206 303 130 147 163 179 212 309 136 153 169 185 218 315 SP-Series Design Bottom Chord Radius ft 1036 620 443 310 195 103 1035 620 442 309 194 102 1035 619 442 309 194 102 1034 619 441 308 193 101 1034 618 441 308 193 101 1033 618 440 307 192 100 1552 773 514 384 256 130 1552 772 513 384 255 129 1551 772 513 383 255 129 1551 771 512 383 254 128 Special Profile Joists Top Chord Radius ft 1041 626 448 315 200 108 1041 626 448 315 200 108 1041 626 448 315 200 108 1041 626 448 315 200 108 1041 626 448 315 200 108 1041 626 448 315 200 108 1561 781 522 393 264 138 1561 781 522 393 264 138 1561 781 522 393 264 138 1561 781 522 393 264 138 Introduction Span ft 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 Chord Depth in 66 66 66 66 66 66 72 72 72 72 72 72 78 78 78 78 78 78 84 84 84 84 84 84 90 90 90 90 90 90 96 96 96 96 96 96 102 102 102 102 102 102 108 108 108 108 108 108 114 114 114 114 114 114 120 120 120 120 120 120 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 85 Introduction Arch Joist (SPAC) Tables SP-Series Tables SP-Series Design Special Profile Joists Span ft 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 Chord Depth in 70 70 70 70 70 70 76 76 76 76 76 76 82 82 82 82 82 82 88 88 88 88 88 88 94 94 94 94 94 94 100 100 100 100 100 100 106 106 106 106 106 106 112 112 112 112 112 112 118 118 118 118 118 118 124 124 124 124 124 124 Top Chord Radius ft 1121 674 483 340 216 117 1121 674 483 340 216 117 1681 841 562 423 284 149 1681 841 562 423 284 149 1681 841 562 423 284 149 1681 841 562 423 284 149 1681 841 562 423 284 149 1681 841 562 423 284 149 1681 841 562 423 284 149 1681 841 562 423 284 149 Bottom Chord Radius ft 1115 668 477 334 210 111 1115 667 476 333 210 110 1674 835 555 416 278 142 1673 834 555 416 277 141 1673 834 554 415 277 141 1672 833 554 415 276 140 1672 833 553 414 276 140 1671 832 553 414 275 139 1671 832 552 413 275 139 1670 831 552 413 274 138 Shape Depth in 96 114 131 158 210 350 102 120 137 164 216 356 100 117 135 152 187 292 106 123 141 158 193 298 112 129 147 164 199 304 118 135 153 170 205 310 124 141 159 176 211 316 130 147 165 182 217 322 136 153 171 188 223 328 142 159 177 194 229 334 Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 112 111 112 112 113x>2 139x>2 101 101 101 112 113x>2 129x>2 94 94 94 94 112 115x>2 91 94 94 94 94 115x>2 83 83 91 91 95 116x>2 81 84 92 92 92 119x>2 82 83 90 94 94 111x>2 81 83 84 94 95 112 81 81 84 85 97 114 81 82 82 94 97 115 112 122 112 123 123x>2 140x>2 101 112 113 113 114x>2 140x>2 94 102 101 112 113 126x>2 95 95 95 102 113 127x>2 92 95 96 96 96 116x>2 92 92 93 93 97 119x>2 91 93 94 94 98 118x>2 93 92 94 94 99 119 85 85 94 96 97 114 90 93 94 94 97 116 123 123 123 123 135x>2 151x>2 113 113 113 113 124x>2 150x>2 103 113 113 113 113 137x>2 96 103 103 114 114 127x>2 96 97 96 96 114 117x>2 93 97 97 97 109 120x>2 95 95 95 99 110 130x>2 95 96 95 96 100 130 94 96 96 96 102 121 94 95 97 97 97 123 Joist Self-Weight - Pounds per Linear Foot (plf) 48 48 52 56 56x>2 66x>2 47 48 48 48 56 66x>2 46 46 47 47 49 61x>2 46 46 46 48 48 62x>2 42 47 47 48 49 59x>2 47 48 48 49 50 62x>2 48 49 50 50 52 62 50 51 53 53 53 67 46 51 53 54 55 67 55 55 55 55 55 71 56 56 56 60 67x>2 70x>2 53 56 56 57 61x>2 70x>2 49 49 56 57 60 65x>2 49 50 50 57 58 67x>2 49 50 50 51 55 67x>2 49 50 51 51 57 70x>2 50 51 51 56 58 70 53 53 54 58 59 71 53 54 55 56 60 74 55 55 55 59 60 75 63 63 64 67 71x>2 82x>2 57 60 60 64 68x>2 79x>2 58 58 61 61 65 74x>2 58 58 58 62 65 75x>2 51 58 59 59 63 72x>2 51 56 56 60 64 74x>2 52 56 57 61 65 70x>2 54 58 60 64 70 76 55 55 60 62 69 74 55 59 59 64 68 76 67 70 71 71 79x>2 91x>2 64 67 68 71 76x>2 91x>2 61 65 68 68 68 78x>2 62 62 62 69 69 79x>2 59 59 63 63 70 80x>2 59 63 64 64 68 79x>2 57 65 66 69 69 79x>2 60 63 68 70 71 79 60 61 66 69 73 83 58 64 65 69 73 84 71 79 79 79 88x>2 96x>2 72 72 72 77 80x>2 92x>2 69 69 69 72 77 90x>2 66 69 70 70 78 91x>2 64 64 70 70 71 91x>2 64 64 68 68 72 90x>2 65 66 70 70 73 91x>2 67 68 72 71 74 91 65 68 72 73 74 94 65 66 73 73 73 96 80 80 80 92 93x>2 116x>2 80 80 80 80 89x>2 108x>2 72 73 77 77 80 90x>2 70 73 73 78 81 91x>2 71 71 71 74 79 92x>2 68 71 71 72 80 94x>2 70 70 73 73 79 95x>2 71 72 73 75 79 96 72 73 73 74 77 98 72 73 73 74 81 99 92 99 92 93 112x>2 116x>2 81 81 93 93 93x>2 116x>2 78 81 81 81 89 107x>2 74 78 81 81 90 107x>2 72 75 75 79 82 92x>2 72 72 75 80 80 94x>2 73 74 74 81 82 95x>2 72 75 75 80 83 96 73 73 76 77 85 98 73 74 74 77 82 99 101 100 100 111 112x>2 117x>2 93 93 93 93 112x>2 117x>2 81 89 93 93 93 114x>2 82 82 90 90 94 115x>2 80 80 82 82 91 108x>2 80 80 80 84 92 110x>2 78 81 82 82 93 111x>2 80 80 83 83 94 112 76 76 77 85 93 98 78 81 82 82 94 111 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' 86 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 10 rows Arch Joist (SPAC) Tables Top Chord Uniform Load - Pounds per Linear Foot (plf) (ASD) 300 350 400 450 500 550 600 650 700 750 800 112 113 113 112 123 137x>2 103 113 113 113 114 137x>2 96 103 113 113 114 127x>2 96 96 96 96 114 116x>2 93 97 97 98 116 119x>2 93 94 94 98 109 130x>2 95 96 95 96 100 131x>2 93 96 96 97 98 122x>2 94 94 97 97 98 122 84 87 96 98 100 116 123 123 123 123 124 138x>2 114 114 114 114 124 138x>2 114 114 114 114 114 138x>2 97 104 115 115 115 128x>2 98 98 99 116 116 130x>2 93 97 98 98 116 130x>2 96 96 100 100 111 131x>2 96 97 97 101 113 133x>2 96 98 98 99 103 134 97 97 100 100 105 124 124 124 124 134 135 158x>2 115 124 124 124 135 148x>2 115 115 115 115 135 148x>2 116 116 116 115 116 139x>2 99 105 116 117 117 141x>2 98 99 110 116 117 131x>2 100 100 112 112 119 132x>2 97 97 101 102 121 134x>2 98 99 103 103 114 135x>2 100 100 100 101 116 136 Joist Self-Weight - Pounds per Linear Foot (plf) 52 52 56 56 57 65x>2 49 49 49 57 57 66x>2 48 48 50 54 58 66x>2 48 48 49 50 55 67x>2 50 50 50 51 57 69x>2 49 49 50 51 56 70 54 54 54 58 58 71 53 54 54 55 60 75 53 53 55 56 60 74 54 55 56 56 61 76 56 57 60 60 67 69x>2 57 57 57 61 65 69x>2 58 58 58 61 65 75x>2 51 55 59 59 63 71x>2 52 56 57 60 65 70x>2 51 55 57 57 65 70x>2 54 59 59 64 70 76 55 55 60 60 67 75 55 59 60 61 66 75 57 57 61 61 68 76 64 68 68 68 71 81x>2 65 65 68 69 69 78x>2 62 62 66 69 69 78x>2 59 63 63 63 70 76x>2 60 64 64 65 68 78x>2 57 64 65 68 69 79x>2 60 67 69 72 70 80x>2 60 61 65 69 74 83 60 60 66 73 74 83 61 62 68 68 75 84 71 71 71 76 80 90x>2 69 72 72 72 77 90x>2 69 69 69 70 78 91x>2 64 70 70 70 71 91x>2 64 68 71 72 72 93x>2 64 69 69 69 73 91x>2 67 71 73 73 75 92x>2 68 69 72 73 75 95 66 70 73 74 74 95 66 67 75 75 76 93 80 80 80 80 88 94x>2 73 78 81 81 89 95x>2 73 73 78 78 89 91x>2 71 71 71 74 79 92x>2 71 72 72 72 80 93x>2 69 72 73 72 81 95x>2 72 72 76 76 80 96x>2 72 73 73 77 83 98 72 73 73 74 82 99 73 75 75 76 79 97 84 92 100 93 93 114x>2 81 81 89 93 94 114x>2 78 81 81 89 90 107x>2 75 79 79 82 90 96x>2 72 75 80 80 92 98x>2 73 73 81 81 93 106x>2 75 75 81 84 92 108x>2 73 76 77 81 86 99x>2 73 73 77 82 85 99 74 75 76 79 84 100 93 93 101 100 112 114x>2 94 94 94 94 102 115x>2 82 90 90 94 94 114x>2 83 83 91 91 91 108x>2 81 81 84 92 92 110x>2 81 81 81 92 93 111x>2 80 83 84 91 94 112x>2 76 77 84 85 97 110x>2 76 77 82 85 96 114 75 79 83 84 95 111 101 112 112 112 112 115x>2 95 102 102 102 113 125x>2 95 95 95 95 113 115x>2 92 92 96 95 96 116x>2 84 92 92 93 97 118x>2 82 92 93 93 98 118x>2 84 84 95 95 95 120x>2 85 85 86 96 97 115x>2 82 85 86 96 97 114 84 83 87 96 99 116 X - BridgingRequirements Requirements– -Reference ReferenceStandard SP-Series Specification Section 904.5 BRIDGING on page X-Bridging Specification Section 904.5 Bridging on page 96 92 1 row 2 rows 3 rows 4 rows 5 rows 6 rows 7 rows 8 rows 9 rows SP-Series Tables Shape Depth in 95 114 132 151 189 301 101 120 138 157 195 307 107 126 144 163 201 313 113 132 150 169 207 319 119 138 156 175 213 325 125 144 162 181 219 331 131 150 168 187 225 337 137 156 174 193 231 343 143 162 180 199 237 349 149 168 186 205 243 355 SP-Series Design Bottom Chord Radius ft 1794 895 596 447 298 153 1794 895 596 446 298 153 1793 894 595 446 297 152 1793 894 595 445 297 152 1792 893 594 445 296 151 1792 893 594 444 296 151 1791 892 593 444 295 150 1791 892 593 443 295 150 1790 891 592 443 294 149 1790 891 592 442 294 149 Special Profile Joists Top Chord Radius ft 1801 902 602 453 305 159 1801 902 602 453 305 159 1801 902 602 453 305 159 1801 902 602 453 305 159 1801 902 602 453 305 159 1801 902 602 453 305 159 1801 902 602 453 305 159 1801 902 602 453 305 159 1801 902 602 453 305 159 1801 902 602 453 305 159 Introduction Span ft 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 Chord Depth in 76 76 76 76 76 76 82 82 82 82 82 82 88 88 88 88 88 88 94 94 94 94 94 94 100 100 100 100 100 100 106 106 106 106 106 106 112 112 112 112 112 112 118 118 118 118 118 118 124 124 124 124 124 124 130 130 130 130 130 130 10 rows Standard Specification Bearing line have have aa seat seat depth depth indicated indicated in in the the chart chart below below Bearing Seat Seat Depth Depth –- Profiles to the right of a colored line Minimum 5" 7½" 10" Maximum 12½" Horizontal 'бxx>2' have a horizontal slip greater than 2". (Reference page 10) 14) Horizontal Deflection Deflection –- Joist designs marked with the note ' Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 87 Introduction • High-Strength Low-Alloy Structural Steel with 50 ksi (345 MPa) Minimum Yield Point to 4 inches (100 mm) thick, ASTM A588/ A588M Special Profile Joists This specification covers the design, manufacture and use of Special Profile Steel Joists, SP-Series. Load and Resistance Factor Design (LRFD) and Allowable Strength Design (ASD) are included in this specification. The term “Special Profile Steel Joists, SP-Series” as used herein, refers to open web, load-carrying members utilizing hotrolled or cold-formed steel, including cold-formed steel whose yield strength has been attained by cold working. SP-Series steel joists are suitable for the direct support of roof decks in buildings. SP-Series Design The design of SP-Series joists’ chord and web sections shall be based on a yield strength of at least 36 ksi (250 MPa), but not greater than 50 ksi (345 MPa). Steel used for SP-Series joist chord or web sections shall have a minimum yield strength determined in accordance with one of the procedures specified in Section 902.2, which is equal to the yield strength assumed in the design. SP-Series joists shall be designed in accordance with these specifications to support the loads specified in the joist designation. SP-Series Tables The term “Yield Strength” as used herein shall designate the yield level of a material as determined by the applicable method outlined in paragraph 13.1 “Yield Point,” and in paragraph 13.2 “Yield Strength,” of ASTM A370, Standard Test Methods and Definitions for Mechanical Testing of Steel Products, or as specified in Section 902.2 of this specification. 902.1 STEEL The steel used in the manufacture of chord and web sections shall conform to one of the following ASTM specifications: • Carbon Structural Steel, ASTM A36/A36M • High-Strength Low-Alloy Structural Steel, ASTM A242/A242M Standard Specification • High-Strength Carbon-Manganese Steel of Structural Quality, ASTM A529/A529M, Grade 50 • High-Strength Low-Alloy Columbium-Vanadium Structural Steel, ASTM A572/A572M, Grade 42 and 50 88 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools • Steel, Sheet and Strip, High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, with Improved Corrosion Resistance, ASTM A606 • Steel, Sheet, Cold-Rolled, Carbon, Structural, High Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, ASTM A1008/A1008M • Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength, ASTM A1011/ A1011M or shall be of suitable quality ordered or produced to other than the listed specifications, provided that such material in the state used for final assembly and manufacture is weldable and is proven by tests performed by the producer or manufacturer to have the properties specified in Section 902.2. 902.2 MECHANICAL PROPERTIES The yield strength used as a basis for the design stresses prescribed in Section 903 shall be either 36 ksi (250 MPa) or 50 ksi (345 MPa). Evidence that the steel furnished meets or exceeds the design yield strength shall, if requested, be provided in the form of an affidavit or by witnessed or certified test reports. For material used without consideration of increase in yield strength resulting from cold forming, the specimens shall be taken from as-rolled material. In the case of material, the mechanical properties of which conform to the requirements of one of the listed specifications, the test specimens and procedures shall conform to those of such specifications and to ASTM A370. In the case of material, the mechanical properties of which do not conform to the requirements of one of the listed specifications, the test specimens and procedures shall conform to the applicable requirements of ASTM A370, and the specimens shall exhibit a yield strength equal to or exceeding the design yield strength and an elongation of not less than (a) 20 percent in 2 inches (51 mm) for sheet and strip, or (b) 18 percent in 8 inches (203 mm) for plates, shapes, and bars with adjustments for thickness for plates, shapes, and bars as prescribed in ASTM A36/A36M, A242/ A242M, A529/A529M, A572/A572M, A588/A588M, whichever specification is applicable on the basis of design yield strength. The number of tests shall be as prescribed in ASTM A6/A6M for plates, shapes, and bars; and ASTM A606, A1008/A1008M and A1011/A1011M for sheet and strip. STANDARD SPECIFICATION, SP-SERIES a) The yield strength calculated from the test data shall equal or exceed the design yield strength. c) Where compression tests are used for acceptance and control purposes, the specimen shall withstand a gross shortening of 2 percent of its original length without cracking. The length of the specimen shall be not greater than 20 times the least radius of gyration. 902.3 WELDING ELECTRODES The following electrodes shall be used for arc welding: b)For connected members both having a specified minimum yield strength of 36 ksi (250 MPa) or one having a specified minimum yield strength of 36 ksi (250 MPa), and the other having a specified minimum yield strength greater than 36 ksi (250 MPa): a) Steel Structures Painting Council Specification, SSPC No. 15 b) Shall be a shop paint which meets the minimum performance requirements of the above listed specification 903.1 METHOD SP-Series joists shall be designed in accordance with these specifications as simply supported, uniformly loaded trusses supporting a roof deck so constructed as to brace the top chord of the joists against lateral buckling. All joists are designed as pinned at one end and roller bearing on the opposite end to prevent horizontal thrust to the supporting structure. The end fixity conditions of Scissor and Arch joists require special consideration from the specifying professional regarding end anchorage conditions. (See Sections 904.1 and 904.7) Where any applicable design feature is not specifically covered herein, the design shall be in accordance with the following specifications: a)Where the steel used consists of hot-rolled shapes, bars or plates, use the American Institute of Steel Construction, Specification for Structural Steel Buildings. b)For members that are cold-formed from sheet or strip steel, use the American Iron and Steel Institute, North American Specification for the Design of Cold-Formed Steel Structural Members. SP-Series Tables a) For connected members both having a specified minimum yield strength greater than 36 ksi (250 MPa): AWS A5.1: E70XX AWS A5.5: E70XX-X AWS A5.17: F7XX-EXXX, F7XX-ECXXX flux-electrode combination AWS A5.18: ER70S-X, E70C-XC, E70C-XM AWS A5.20: E7XT-X, E7XT-XM AWS A5.23: F7XX-EXXX-XX, F7XX-ECXXX-XX AWS A5.28: ER70S-XXX, E70C-XXX AWS A5.29: E7XTX-X, E7XTX-XM The standard shop paint is intended to protect the steel for only a short period of exposure in ordinary atmospheric conditions and shall be considered an impermanent and provisional coating. When specified, the standard shop paint shall conform to one of the following: SP-Series Design d) If any test specimen fails to pass the requirements of the subparagraphs (a), (b), or (c) above, as applicable, two retests shall be made of specimens from the same lot. Failure of one of the retest specimens to meet such requirements shall be the cause for rejection of the lot represented by the specimens. 902.4 PAINT Special Profile Joists b) Where tension tests are made for acceptance and control purposes, the tensile strength shall be at least 6 percent greater than the yield strength of the section. Introduction If as-formed strength is utilized, the test reports shall show the results of tests performed on full section specimens in accordance with the provisions of the AISI North American Specifications for the Design of Cold-Formed Steel Structural Members. They shall also indicate compliance with these provisions and with the following additional requirements: Design Basis: Designs shall be made according to the provisions in this Specification for either Load and Resistance Factor Design (LRFD) or for Allowable Strength Design (ASD). AWS A5.1: E60XX AWS A5.17: F6XX-EXXX, F6XX-ECXXX flux-electrode combination AWS A5.20: E6XT-X, E6XT-XM AWS A5.29: E6XTX-X, E6XTX-XM or any of those listed in Section 902.3(a) Load Combinations: Other welding methods, providing equivalent strength as demonstrated by tests, may be used. 1.4D 1.2D + 1.6 (L, or Lr, or S, or R) LRFD: Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification When load combinations are not specified to NMBS, the required stress shall be computed for the factored loads based on the factors and load combinations as follows: 89 STANDARD SPECIFICATION, SP-SERIES ASD: QFy Special Profile Joists Introduction F ASD: QFy ASD: Fcr Q 0.658 e F When load combinations are not specified to NMBS, the y F ASD: QF y e 0.658 requiredWhen stressload shall be computed based on theto load F Q F combinations are not specified NMBS, the cr 0.658 Fe F y (903.2-3) F Q When load combinations are not specified to NMBS, the When load combinations are not specified to NMBS, the required combinations as follows: required stress shall be computed based on the load cr y ASD: QFy requiredcombinations stress shall be computed based on the loadas follows: (903.2-3) asbe follows: stress shall computed based on the load combinations F e D (903.2-3) Fcr Q 0.658 Fy(903.2-3) When load combinations are not specified to NMBS, the combinations as follows: D + (L, or S, or R)stress shall be computed based on the load D Lr, or required D D D + (L, or Lr, or S, or For members with K 4.71 E (903.2-3 combinations asR) follows: r QFy E D +S,(L,ororR) Lr, or S, or R) K D + (L, or Lr, or Where: For members with For members with 4.71 QFy D Where: For members with K 4.71r E D = dead loadDdue weight of the structural r QFy Where: + (L, to or Lthe r, or S, or R) Where: elements andload the due permanent featuresof ofthethe D = dead to the weight structural For members with K 4.71 E D= dead due the weight the structural r QFy Fcr 0.877 Fe (903.2-4) D = dead load dueload toand thetothe weight of ofthe structural structure elements permanent features elements of the Where: Fcr = 0.877F (903.2-4) and permanent features of theequipment structure and the permanent features of the Fecr 0.877 Fe (903.2-4) L = elements live loadstructure due tothe occupancy and movable Dload = due dead load due and to movable the weight of the structural Fcr 0.877 Fe (903.2-4) Lr = structure roof load L live =L live and movable equipment = live load duetotooccupancy occupancy equipment elements andmovable the permanent buckling stress determined in accordance L load tolive occupancy and equipment features of the FFe ==Elastic S = live snow load LrL = live load =due load rroof roof Elastic buckling determined in accordance e Fcr stress 0.877 Fe (903.2-4 structure L load with Equation 903.2-5 Rr = roof load due to initial rainwater or ice exclusive of the S live =S= snow load with Equation 903.2-5 snow load buckling stress determined in accordance F e = Elastic L = live load due to occupancy and movable equipment S = snow load ponding contribution R = load due to initial rainwater or ice exclusive of the determined in accordance Fe = Elastic with buckling Equationstress 903.2-5 R=to load due to initial rainwater or ice exclusive of the Lrinitial =contribution roof live load R = load dueponding rainwater or ice exclusive of the with Equation 903.2-5 2 ponding contribution E S = snow load Loads for Buildings and contribution The currentponding ASCE 7, Minimum Design determined in accordan (903.2-5) F 2Fe = Elastic buckling stress 2 E R be=7,load due initial and rainwater orload ice exclusive of the e Other Structures used for toDesign LRFD ASD The currentshall ASCE Minimum Loads for Buildings and (903.2-5) with Equation 903.2-5 2 KF (903.2-5) ponding contribution The current ASCE 7, Minimum Design Loads forLRFD Buildings The current ASCE 7,pertains Loads for Buildings combinations. This provision exclusively to and the Other Structures shall beMinimum used forDesign and ASD load reE K 2 (903.2-5) Fe 2 Other Structures shall bedoes used for LRFD ASD load combination ofand loads and notshall imply that NMBS verify orASD combinations. This provision pertains to load the r Other Structures be usedand forexclusively LRFD and 2 E For hot-rolledKsections, “Q” is the full reduction factor for slender Theofprovision current ASCE 7, Profile Minimum Design Loads for Buildings and combinations. This pertains exclusively to the generatecombination load combinations. development for Special Joists. r loads and does not imply that NMBS verify or (903.2-5 Fe This provision pertains exclusively to the 2 compression elements. Other Structures shall be used for LRFD and ASD load combination of loads does not for imply that Profile NMBS Joists. verify or generate load and development Special For hot-rolled sections, “Q” K is the full reduction factor for combination of loads and does not imply that NMBS generate or combinations. This provision pertains exclusively to slender the generate load development for Special Profile Joists. 903.2 DESIGN AND ALLOWABLE STRESSES compression For hot-rolledelements. sections,r “Q” is the full reduction factor for verify load development for SP-Series. Design Stress = 0.9F (LRFD) combination of loads and STRESSES does not imply that NMBS verify or crthe 903.2 DESIGN AND ALLOWABLE For hot-rolled sections, “Q” iselements. full reduction (903.2-6) factor for slender compression generate load development for Special Profile Joists. Allowable Stress = 0.6F (ASD) (903.2-7) 903.2 DESIGN AND ALLOWABLE STRESSES Design Using Load and Resistance Factor Design (LRFD) slender compression Design Stress elements. = 0.9Fcrcr(LRFD) (903.2-6) 903.2 DESIGN STRESSES ForStress hot-rolled sections, “Q” is(903.2-7) the full(903.2-6) reduction factor Design Using LoadAND and ALLOWABLE Resistance Factor Design (LRFD) Allowable Stress = 0.6Fcr =(ASD) Design 0.9Fcr (LRFD) 903.2 ANDso ALLOWABLE In theDesign above equations, ℓ is taken as the distance in inches (mm) Design Using Load andDESIGN Resistance Factor Design STRESSES (LRFD) slender compression elements. Joists shall have their components proportioned that the Stress =Stress 0.9F (LRFD) (903.2-6) Allowable = 0.6F (ASD) (903.2-7) cr cr Design Usingnot Load and Resistance Factor Designthat (LRFD) between panel points for the chord andthe the appropriate shallfu, have their components so proportioned the requiredJoists stresses, shall exceed Fn where, Allowable Stress = 0.6F (ASD) (903.2-7) in In the above equations, crismembers taken as distance Design Using Load and Resistance Factor Joists shall havestresses, their components proportioned that the Design (LRFD) Stress = 0.9F (903.2-6 cr required fu, shall notso exceed Fn where, length web members, and r ispoints the corresponding least radius In the above Design equations, foristhe taken as(LRFD) the distance in inchesfor(mm) between panel chord members Joistsfustress their ksi components so proportioned that the Allowable Stress = 0.6F (ASD) (903.2-7 required ,shall shallhave not exceed F cr fu stresses, = required (MPa) n where, In the above equations, is taken as the distance in between panel points for and the members and the inches appropriate length forcomponent web members, requal is the of gyration of the (mm) member or any thereof. E ischord shall have their components so proportioned thatinches the (mm) between panel points for the chord members stresses, fu, shall not exceed ΦFn where, Fn = nominal stress ksi (MPa) furequired =Joists required stress ksi (MPa) and theleast appropriate length for web members, corresponding radius of gyration of the memberand or r is the to 29,000 ksi (200,000 MPa). stresses, fu, shall not (MPa) exceed Fn where, In length theleast equations, ksi isof(200,000 taken as the or distance fu = required stress (MPa) Fn =required stress ksi resistance and the corresponding appropriate web members, and r is member the of 29,000 gyration the any component thereof. Eabove isforradius equal to funominal stress =factor required stress (MPa) ksi ksi (MPa) F inches (mm) between panel points for the chord nn = =stress resistance factor ksi F = nominal design ksi (MPa) corresponding least radius of gyration of the member or thereof. E is equal to 29,000web ksi (200,000 memb MPa). Use 1.2 any ℓ/rx component for a crimped, first primary compression Fn =factor stress stress ksi (MPa) funominal = required = resistance and the appropriate length for web members, and r is Fn = design stress ksi (MPa) ksi (MPa) any component thereof. E is equal to 29,000 ksi (200,000 MPa).a moment-resistant weld group is not used for member when Allowable Φstress =Fresistance factor = nominal stress n Strength = design ksi (MPa) Fn Using corresponding least radius of gyration of the member Design Design (ASD) ksi (MPa) MPa). r for a crimped, first primary compression web Use 1.2 this member; xwhere any rx = member radiusthereof. of gyration the plane = resistance factor Using ΦFn =Allowable design stress ksi Design (MPa) (ASD) component E isinequal 29,000web ksi (200,0 Design Strength r x for a crimped, first primary Use 1.2amoment-resistant member when weld group iscompression not to used Joists shall have theirFcomponents so proportioned that the of the joist. = design stress (MPa) n Strength Design Using Allowable Design (ASD) ksi MPa). r for a crimped, first primary compression web Use 1.2 member when weld group isinnot used of gyration for this member; wherea rmoment-resistant x shallf, shall have their components so Design proportioned / where, requiredJoists stresses, not exceed FnStrength x = member radius Design Using Allowable (ASD) that the member when amember; moment-resistant weld groupthe is nominal not of used rof member radius gyration in for where thecold-formed plane ofthis the joist. Joists shall havestresses, their components so proportioned that the required f, shallAllowable not exceed Fn / where, x =calculating For sections the method Design Using Strength Design (ASD) first primaryincompression w Use 1.2 Joistsf, stress shall not haveexceed their ksi components so proportioned that the rx=r member radius of gyration for this member; where x for a crimped, the plane of the joist. required shall Fn(MPa) / where, fu stresses, = required column strength is given in the AISI North American Specification member a moment-resistant shall have their components so proportioned thatthe theplane of the joist. stresses, f, shallksi not(MPa) exceed Fn /Ὼ where, For sections when the method of calculatingweld thegroup is not us Fn = nominal stress fu required =Joists required stress ksi (MPa) for thecold-formed Design of Cold-Formed Steel Structural Members. r = member radius of for this member; where required stresses, f, shall not exceed F / where, x f = required stress stress ksi (MPa) nominal For column strengthsections is given the AISI North cold-formed the inmethod of calculating thegyration Fn =factor (MPa) n safety u funominal stress = required stress ksiksi (MPa) the plane of the joist. For cold-formed sections the method of calculating the F = nominal ksi (MPa) American Specification for the Design of Cold-Formed nominal column strength is given in the AISI North n = safety factor Fn/ = allowable stress ksi (MPa) (c) Bending: Φb = 0.90 (LRFD), Ὼb = 1.67 (ASD) Fn fu= nominal stress ksi (MPa) = required nominal column strength is given in Design the AISIof North Steel Structural Members. American Specification for the Cold-Formed = safety Stresses: = allowable stress stress ksi (MPa) ksi (MPa) Fn/ factor For cold-formed sections method of calculating Ὼ stress factor ksi F=n safety = nominal stress ksi (MPa) American Specification for the Design of the Cold-Formed Steel Structural Members. Fn/Stresses: = allowable (MPa) Bending calculationsnominal are to be based strength on using isthegiven elasticin the AISI No (a) Tension: t = 1.67 (ASD) column t =0.90 = (LRFD), safetystress factor Steel StructuralMembers. Fn/Ὼ= allowable ksi (MPa) (c) Bending: Stresses: b = 0.90 (LRFD), b = 1.67 (ASD) section modulus. American Specification for the Design of Cold-Form (a) Tension: = 0.90 (LRFD), = 1.67 (ASD) t t ksi (MPa) Fn/ = allowable stress (c) Bending: b = 0.90 (LRFD), b = 1.67 (ASD) (a) Tension: t = 0.90F(LRFD), (ASD) For Chords: MPa) Structural t = 1.67 y = 50 ksi(345 Stresses: Stresses: (c) Bending: b =Steel 0.90 (LRFD), Members. (ASD)the elastic Bending calculations are to be based on using b = 1.67 section For chords and web members other than solid rounds: For Webs: Fy = 50 ksi MPa), For Chords: Fy =(345 50 ksi (345orMPa) modulus. Bending calculations are to be based on using the elastic (a) For Tension: Ὼksi = (LRFD), 1.67 (a) ΦTension: =50 0.90 t =or1.67 (ASD) tMPa) For Chords: Ft y===0.90 50 ksi MPa) 36 (LRFD), ksi (250 F ksi (345modulus. MPa) (345(ASD) MPa), Webs: Fy=t(345 (c) are Bending: b = 0.90 (LRFD), y = 50section b = 1.67 (ASD) Bending calculations to be based on using theelastic For Webs: Fy = 50 ksi (345 MPa), Fy = 36 ksi (250orMPa) section Formodulus. chords and web members other than solid For chords:For Fy =ksi 50(250 ksi (345 FyMPa) = 50 (903.2-1) ksi (345 MPa) Fy ==Chords: 36 MPa) Design Stress 0.9F Design Stress calculations are to be (903.2-8) based than on using y (LRFD) y (LRFD) rounds: For Bending chords= 0.9F and web members other solidthe ela = 50or ksi (345(903.2-1) MPa), or For= Webs: FyMPa) ForStress webs: Fy = y50(ASD) (345 Allowable 0.6F (903.2-2) Design Stress = ksi 0.9F section y (LRFD) Allowable Stress =modulus. 0.6Fmembers (903.2-9) For chords and web other than solid y (ASD) rounds: Fy = 50 ksi (345 MPa) FyMPa) = 36(903.2-1) ksi (250(903.2-2) MPa) Design Stress = 0.9F (LRFD) Allowable Stress = ksi 0.6F F (250 y (ASD) y = y36 rounds: Fy = 50ofksi (345 MPa) Stressc = = 0.6F y (ASD)c = 1.67(903.2-2) (b) Allowable Compression: 0.90 (LRFD), (ASD) For chords web members other than s For web members solid round crossand section: F ksi (345 MPa) Design = 0.9Fy (LRFD) (903.2-8) DesigncStress = 0.9F y = 50 Stress rounds: (b) Compression: = 0.90 (LRFD), cy=(LRFD) 1.67 (ASD) Design Stress = 0.9F (903.2-1)(903.2-1) y (LRFD) F = 50 ksi (345 MPa) or F = 36 ksi (250 MPa) StressStress =y 0.6Fy (ASD) (903.2-9)(903.2-8) Allowable Stressc ==1.67 0.6F(ASD) (903.2-2) yAllowable Design = 0.9F y (ASD) y (LRFD) (b) Compression: = 0.90 (LRFD), c E = 0.6Fy (ASD) (903.2-2) 50 ksi For membersAllowable with K Stress 4.71 y = 0.9F Design Stress AllowableFStress =(345 0.6FMPa) (903.2-9) y (LRFD) y (ASD) (903.2-8) QFy E r StressStress of==solid 1.45F (903.2-10) y (LRFD) K For members with 4.71c = 0.90 (LRFD), c = 1.67 (ASD) Design Allowable 0.6Fround (903.2-9) For web members cross section: y (ASD) (b) Compression: QF (b) Compression: =r 0.90 c =y 1.67 (ASD) E (LRFD), Ὼ Allowable Stress = 0.95F (903.2-11) yof(ASD) For members with K 4Φ.c71 Design Stress = 0.9F (903.2-8 y (LRFD) For web members solid round cross section: QFy r Fy =web 50 ksi (345 MPa), or Fround = 36cross ksi (250 MPa) y Stress Allowable =section: 0.6F (903.2-9 y (ASD) For members of solid Fy = 50 ksi (345 MPa), or Fy = 36 ksi (250 MPa) For with K 4.71 E For members members with QFy r ksi (345 MPa), or Fmembers 36 ksi of (250 MPa) F Design 1.45F (903.2-10) y = 50 Stress y y=(LRFD) For= web solid round cross section: Design Stress = 1.45Fy (LRFD) (903.2-10) Fy == 1.45F 50 ksiy (345 MPa), or (903.2-10) Fy = 36 ksi (250 MPa) Design Stress (LRFD) Discover the easiest way to specify special profile joists: Standard Specification SP-Series Tables SP-Series Design 90 www.newmill.com/digital-tools Design Stress = 1.45Fy (LRFD) 85 (903.2-1 STANDARD SPECIFICATION, SP-SERIES For bearing plates: Design Stress = 1.35Fy (LRFD) (903.2-12) Stress (ASD) Fy = Allowable 50 ksi (345 MPa), or F=y 0.90F = 36 yksi (250 MPa) (903.2-13) (d) Weld Strength: = 1.35Fy (LRFD) Design Stress Allowable Stress = 0.90Fy (ASD) (903.2-12) (903.2-13) Shear at throat of fillet welds: (d) Weld Strength: Nominal Shear Stress = Fnw = 0.6Fexx (903.2-14) Nominal LRFD: ΦwShear = 0.75 Stress = Fnw = 0.6Fexx (903.2-14) = 0.75 LRFD: wDesign Shear Strength = ΦRn Shear = ΦwFnwStrength A = 0.45F=exx A Design Rn = wFnw A = 0.45Fexx A ASD: Ὼw = 2.0 (903.2-15) (903.2-15) ASD: w = 2.0 Allowable Shear Strength = Allowable Shear Strength = R /Ὼ = FnwA/Ὼw = 0.3Fexx A Rn/wn = FwnwA/ w = 0.3Fexx A (903.2-16) (903.2-16) Where = effective throat area Where A =Aeffective throat area flux-electrode combinations. Fexx = 70 ksi (483 MPa) Fexx = 70 ksi (483 MPa) Made with E60 series electrodes or F6XX-EXXX fluxelectrode combinations. Made with E60 series electrodes or F6XX-EXXX flux-electrode combinations. Fexx = 60 ksi (414 MPa) For = 60 ksi (414 MPa) Tension on groove or butt welds shall be exxcompression the same as those specified for the connected material. design element shall be accounted for in the design. (903.2-17) (903.2-17) = axial force required in the member = distance from neutral axis to the extreme fiber results two stresses for asymmetric sections such Pr =axial forceinrequired in the member as double angles moment of inertia about axis perpendicular to radius cIx ==distance from neutral axis to the extreme fiber of divergence results in two stress values for asymmetric sections R = radius of divergence from neutral axis. Usually the such as double radius of coldangles rolling for Bowstring or Arch Joists d = straight-line distance from node to node Pr c Ix = moment of inertia about axis perpendicular to 903.3 MAXIMUM RATIOS radius ofSLENDERNESS divergence The slenderness ratios, 1.0 /r and 1.0 s/r of members as a R = radius of divergence from neutral axis. Usually the whole or any component part shall not exceed the values radius of cold rolling for Bowstring or Arch Joists given in Table 903.3-1, Parts A. deffective = straight-line distance fromK/r* nodetotobe node The slenderness ratio, used in calculating the nominal stresses Fcr and Fe, is the largest value as determined from Table 903.3-1, Parts B and C. 903.3 MAXIMUM SLENDERNESS RATIOS Thecompression slenderness ratios, 1.0 ℓ/rwhen and 1.0 ℓs/rorof ties members as a they In members fillers are used, whole or any component part shall not exceed the values given shall be spaced so that the s/rz ratio of each component does in Table 903.3-1, Parts A. /r ratio of the member as a whole. not exceed the governing The terms used in Table ratio, 903.3-1 defined ascalculating follows: The effective slenderness Kℓ/rare to be used in nominal Fcr and of Fe,panel is thepoints, largestexcept value as the = length stresses center-to-center = 36 in. determined from for Table 903.3-1, /r Parts B and C.member. See P.N. (914 mm) calculating chord y of top T.V. Galambos, Chordsbetween Without panel Fillers point =and maximum length Compression center-to-center Chod s and filler or between fillers (ties).1975 in Longspan Steel(tie), Joists, Research adjacent Report No. 36, June rStructural = member radius gyration inDepartment, the plane ofWashington the joist. x Division, CivilofEngineering = member radius of gyration out of the plane of the joist. rUniversity, y St. Louis, Mo. rz = least radius of gyration of a member component. In compression members or ties are used, they shall * See P.N. Chodwhen andfillers T. V. Galambos, Compression be spaced so thatWithout the ℓs/rz Fillers ratio of each component does Chords in Longspan SteelnotJoists, Report No.of36, 1975 exceed Research the governing ℓ/r ratio theJune member as aStructural whole. Division, Civil Engineering Department, Washington University, St. Louis, Mo. The terms used in Table 903.3-1 are defined as follows: Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools Standard Specification ℓ =length center-to-center of panel points, except ℓ = 36 inches (914 mm) for calculating ℓ/ry of top chord member. ℓs =maximum length center-to-center between panel point and filler (tie), or between adjacent fillers (ties). rx =member radius of gyration in the plane of the joist. ry =member radius of gyration out of the plane of the joist. rz =least radius of gyration of a member component. SP-Series Tables Tension or compression on groove butt welds shallinto be the Divergence Stress: The design of orchords formed same as thosecold specified for shall the connected arches through rolling include material. a divergence stress in the design. A secondary moment in the chord resulting from theStress: divergence of the ofactual Divergence The design chordsmember formed from into arcs the node-to-node linear design element shall be through cold rolling shall include a divergence stress in the accounted for in the design. In some cases the divergence A secondary moment in the chord from stressdesign. may counter act the bending stress of resulting the chord, in the divergence of theofactual memberstress from the node-to-node linear this case the effects divergence is ignored. divergence Pr c d2 2 R R I x 4 SP-Series Design Made withwith E70E70 series F7XX-EXXX flux Made serieselectrodes electrodes or or F7XX-EXXX electrode combinations. shall be equal to: Special Profile Joists Shear at throat of fillet welds: For chords rolled to a radius, the secondary moment stress shallFor be equal to: rolled to a radius the secondary moment stress chords Introduction For bearing plates: Fy = 50Stress ksi (345 MPa) or Fy y=(ASD) 36 ksi (250 MPa) Allowable = 0.95F (903.2-11) 91 Introduction STANDARD SPECIFICATION, SP-SERIES TABLE 903.3-1 MAXIMUM AND EFFECTIVE SLENDERNESS RATIOS kℓ/rx kℓ/ry kℓ/rz kℓs/rz I TOP CHORD INTERIOR PANEL Special Profile Joists A. The slenderness ratios, 1.0ℓ/r and 1.0ℓs/r , of members as a whole or any component part shall not exceed 90. B. The effective slenderness ratio, kℓ/r, to determine Fcr where k is: 1. With fillers or ties 2. Without fillers or ties 3. Single component members 0.75 --- 0.75 1.0 --- 1.0 --- 0.75 --- 1.0 ----- C. The effective slenderness ratio, kℓ/r, to determine Fe where k is: 1. With fillers or ties 2. Without fillers or ties 3. Single component members 0.75 0.75 0.75 --- --- --- --- --- --- ------- II TOP CHORD END PANEL SP-Series Design A. The slenderness ratios, 1.0ℓ/r and 1.0ℓs/r , of members as a whole or any component part shall not exceed 120. B. The effective slenderness ratio, kℓ/r, to determine Fcr where k is: 1. With fillers or ties 2. Without fillers or ties 3. Single component members 1.0 --- 1.0 1.0 --- 1.0 --- 1.0 --- 1.0 ----- C. The effective sl enderness ratio, kℓ/r, to determine Fe where k is: 1. With fillers or ties 2. Without fillers or ties 3. Single component members 1.0 1.0 1.0 --- --- --- --- --- --- ------- 0.75 --- 0.75* 1.0 --- 1.0 --- 1.0 --- 1.0 ----- III TENSION MEMBERS – CHORDS AND WEBS SP-Series Tables A. The slenderness ratios, 1.0ℓ/r and 1.0ℓs/r , of members as a whole or any component part shall not exceed 240. IV COMPRESSION MEMBERS A. The slenderness ratios, 1.0 and 1.0ℓs/r , of members as a whole or any component part shall not exceed 200. B. The effective slenderness ratio, kℓ/r, to determine Fcr where k is: 1. With fillers or ties 2. Without fillers or ties 3. Single component members Standard Specification * If moment-resistant weld groups are not used at the ends of a crimped, first primary compression web member, then 1.2ℓ/rx must be used. 92 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools σdiv = Divergence stress applied where applicable as Introduction defined in Section 903.2.17 STANDARD SPECIFICATION, SP-SERIES Mu = required flexural strength using LRFD load combinations, kip-in (N-mm) 903.4 MEMBERS 4 MEMBERS 903.4 MEMBERS stress applied where applicable as σdiv =σDivergence stress where applicable as where div = Divergence 903.4 MEMBERS =applied Divergence stress applied applicable as aded divDivergence σσdiv =applied Divergence stress applied where applicable .4 MEMBERS903.4 σstress =Section stress applied where applicable as as SMEMBERS = elastic section modulus, in3 (mm3) σdiv = Divergence where applicable as div defined in 903.2.17 903.4 MEMBERS defined in Section 903.2.17 σ = divergence stress applied where applicable as div defined in Section 903.2.17 STANDARD SPECIFICATION – SP SERIES defined in Section 903.2.17 STANDARD SPECIFICATION ––=div=SP SERIES (a) Chords 903.4 MEMBERS defined in Section 903.2.17 903.4 MEMBERS 903.4 MEMBERS = nominal axial compressive stress based on /r as FcrChords Chords Section 903.2.17 STANDARD SPECIFICATION –inDivergence SP SERIES σ Divergence stress applied where applicable σ = stress applied where applicable σdefined Divergence stress applied where applicable asas div required flexural strength using LRFD load as div STANDARD SPECIFICATION SP SERIES Mu =M required flexural strength using LRFD load u (a) Chords defined Equation 903.2-17 required flexural strength using LRFD load (a)(a) Chords Chords MM ==kip-in required flexural strength using LRFD load u=ustrength Muin required flexural strength using LRFD load defined in Section 903.2(b), ksi (MPa) flexural using LRFD load Mu = required (a)Chords combinations, (N-mm) defined in Section 903.2.17 defined in Section 903.2.17 defined in Section 903.2.17 combinations, kip-in (N-mm) shall M = required flexural strength using LRFD load 903.4 MEMBERS combinations, kip-in (N-mm) u 903.4 MEMBERS 3 3 σ = divergence stress applied where applicable as combinations, kip-in (N-mm) 3 3 div σ = divergence stress applied where applicable as The bottom chord shall be designed as an axially loaded combinations, kip-in (N-mm) (a)(a)bottom Chords 903.4 MEMBERS div Chords combinations, kip-in (N-mm) (a) Chords The chord shall be designed as an axially loaded = 1bottom - 0.3 fauchord /F’e for endbepanels CmThe σ = divergence stress applied where applicable as 903.4 MEMBERS elastic section modulus, in (mm ) LRFD = required flexural strength using LRFD load M σ = div divergence stress applicable as = required flexural strength using load M required flexural strength using LRFD load S =S elastic section modulus, in3 where (mm uuM div 33 3 33 u= shall designed asan anaxially axially loaded The bottom chord shall designed loaded 3 ) modulus, ction S =applied elastic section modulus, in (mm The bottom chord shall bebe designed as as an axially loaded The tension bottom chord shall be designed as an axially loaded combinations, (N-mm) Sin =kip-in elastic section (mm )) defined 903.2-17 defined inS Equation 903.2-17 member. =Equation elastic section modulus, in3in(mm SF ==Felastic section modulus, in (mm ) based tension member. C defined in Equation 903.2-17 = 1 0.4 f interior panels The bottom chord shall be designed as an axially loaded mtension au/F’ e for combinations, kip-in (N-mm) combinations, kip-in (N-mm) defined in Equation 903.2-17 combinations, kip-in (N-mm) = nominal axial compressive stress based on /r) as member. nominal axial compressive stress on /r as cr (a) Chords tension member. cr M 3axial 3 compressive (a) Chords tension member. = required flexural strength using LRFD load M tension member. (a) Chords 3 3 u = nominal stress based on/r /ra F = required flexural strength using LRFD load 3 3 S = elastic section modulus, in (mm ) 3 3 (a)bottom Chords =strength nominal axial compressive stress based F The bottom as anan axially loaded The bottom shall designed as axially loaded = required flexural strength using LRFD load M The chord bebe designed loaded cr =cr nominal axial based onon /r as Ftension = shall specified minimum yield strength, ksi (MPa) Fcr = axial compressive stress based as = u== required flexural using LRFD load MuS cr elastic section modulus, in (mm ) ) on ychord member. unominal S = elastic section modulus, in (mm ) /rstress S elastic section modulus, incompressive (mm defined in Section 903.2(b), ksi (MPa) defined in F Section 903.2(b), ksi (MPa) combinations, kip-in (N-mm) combinations, kip-in (N-mm) defined in Section 903.2(b), ksi (MPa) combinations, kip-in (N-mm) tension member. Bottom chords that are rolled for arched chord joist shall defined in Section 903.2(b), ksi (MPa) F = nominal axial compressive stress based on ℓ/r as σ = Divergence stress applied where applicable as tension member. tension member. Bottom chords that are rolled arched chord joist shall combinations, kip-in (N-mm) div 3(MPa) 3903.2(b), 2 for defined in ksi Section ksi (MPa) Section 903.2(b), The bottom chord shall be designed as an axially loaded == nominal axial stress on FFcrdefined The bottom chord shall be designed as an axially loaded 3 3(mm 3) based Bottom chords that are rolled for arched chord joist 1= -elastic 0.3 fau /F’ for end nominal axial compressive stress based on /r nominal axial compressive based on/r /ras asas cr S = section in 1=F 0.3 fin /F’ for end panels Cshall m ecompressive cr Bottom chords that rolled for arched chord joist The bottom shall be are designed as an axially loaded SS=C section modulus, inin3 3panels )3stress mshall au e chord Efor Bottom chords that are rolled for arched chord joist shall The bottom chord shall be designed as an axially loaded Bottom that are rolled arched chord joist shall S=-crelastic = elastic section modulus, in (mm ) end =-1modulus, 1panels -0.3 0.3 f(mm /F’ for end panels C elastic section )(MPa) be chords designed to include divergence stress per Section mmodulus, au efor =Section -903.2(b), f(mm /F’ panels C be designed to include divergence stress per Section defined in Section ksi m au e tension member. defined in Section 903.2.17 = 1 0.3 f /F’ for end panels C = 1 0.3 f /F’ for end C Bottom chords that are rolled for arched chord joist shall tension member. m au e m au e defined in Section 903.2(b), ksi (MPa) = , ksi (MPa) F be designed to include divergence stress per Section defined in 903.2(b), ksi (MPa) tension member. defined in Section 903.2(b), ksi (MPa) e = nominal axial compressive stress based on /r as F C = 1 0.4 f /F’ for interior panels be designed to include divergence stress per Section cr C = 1 0.4 f /F’ for interior panels tension member. m au e compressive = nominal axial compressive stress based on /r as F m au e cr be designed to include divergence stress per Section be designed to include divergence stress per Section 2 = nominal axial stress based on /r as F Bottom chords for arched chord joist shall nominal axial on /r as Fcr1 903.2.17, inchords combination with tension forces. C =-10.4 1end -0.4 0.4 fau/F’ /F’ forinterior interior panels Bottom rolled for arched chord joist shall Bottom chords that rolled joist shall 903.2.17, in combination with tension forces. m efor Cfor -end fstress panels M =that flexural strength using LRFD load m au ebased crdefined 1 --10.3 0.3 fSection //F’ Φ=compressive FSection panels 1=efor fyield /F’ for interior panels CFm C = -= 0.4 /F’ interior panels u903.2.17, (required kare inare /combination rin )combination e/F’ be903.2.17, designed to include divergence stress per Equation au efau au e(MPa) in 903.2(b), ksi (MPa) === 1 fmau for panels C with tension forces. inC ksi specified minimum strength, ksi (MPa) = -minimum 0.3 f/F’ end panels 1f-defined 0.3 for end panels Cm in with tension forces. xcombination =F specified yield strength, (MPa) ym au e for mCm au e903.2(b), y defined in Section 903.2(b), ksiksi (MPa) 903.2.17, indesigned combination with tension forces. 903.2.17, with tension forces. defined in Section 903.2(b), ksi (MPa) Bottom that are rolled for arched chord joist shall bebedesigned designed to tochords include divergence stress per Section F = specified minimum yield strength, ksi(MPa) (MPa) Bottom chords that are rolled for arched chord joist shall include divergence stress per Section be Section y F = specified minimum yield strength, combinations, kip-in (N-mm) y Bottom chords that are rolled for arched chord joist shall F = specified minimum yield strength, ksi (MPa) F = specified minimum yield strength, ksiksi (MPa) C = 1 0.4 f / Φ F for interior panels = 1 0.3 f / F for end panels C y y BottomWhere chordsthat are panel rolled length, for arched chord joist shallas defined in m m 903.2-17, in combination with tension forces. =C 1== -21 0.3 fau /0.4 /fau F end CCmC -1-10.4 /F’ for interior panels 2-f0.3 m eeeend = ffor /F’ for interior panels C 10.3 fauau /F’ for interior panels = -0.4 fFeau /au eF end panels m epanels m efor m au 3per Equation 3 Equation is the in inches (mm), = 1 for panels be designed to include divergence stress per m au e aded 903.2.17, be designed to include divergence stress 903.2.17, forces. 2 E 903.2.17, in combination with tension forces. in combination with tension 2 E beSdesigned to include divergence stress per = to elastic section modulus, in (mm ) Equation 2interior be designed include divergence stress per Equation 1 --fau 0.4 //F panels e for CCmF 1= 0.4 //FffFeau for interior panels F C =2-=specified specified minimum yield strength, ksi (MPa) minimum strength, ksi (MPa) yield yy = = minimum strength, (MPa) C = 1specified for panels specified yield strength, ksiksi (MPa) interior EEyield m au einterior 903.2-17, combination with forces. For LRFD: f aucombination in 9with Ffytension (903.4-1) == , Fksi (MPa) =ym 1 -E 0.4 f0.4 for panels 903.2(b) and r is the of gyration aboutFethe E 903.2-17, forces. For LRFD: f auSection in 0div.LRFD: 9F0y .with (903.4-1) =FF , ksi (MPa) meyF au eminimum x tension 903.2-17, in combination with tension forces. div 2F 903.2-17, in combination tension forces. F = specified minimum yield strength, ksi (MPa) For 90F 0.radius .9FF (903.4-1) = , ksi (MPa) 22,Fminimum yspecified F= = yield strength, ksi (MPa) e For LRFD: =div nominal axial compressive stress based on /r as Fcr f 9 (903.4-1) = , ksi (MPa) F y For LRFD: au div y e For LRFD: f auaxis 0 . 9 F (903.4-1) (903.4-1) ksi (MPa) F For LRFD: f 0 . (903.4-1) F = specified minimum yield strength, ksi (MPa) = , ksi (MPa) au div y e 2 y 2 e 2 Fy ( k=specified minimum yield strength, ksi (MPa) (rkx2 rE ) y au div y 2 / ) of bending. 2/ 2 x E (k(k(/kr/ /)rrx x)) defined 903.2(b), ksi (MPa) k =/=r=x )2E 22EE rtical For LRFD: 0div .60in . 90Section (903.4-1) ,,ksi (MPa) FF(e FWhere x eeFe= For LRFD: F .F9.9yyFFy0(903.4-2) (903.4-1) E For , ksi (MPa) (MPa) f adivfauauLRFD: (903.4-2) For ASD: div shallFor ASD: fFor LRFD: For f1au .60.3 F0fdiv Epanel div 22length, y0 . 9 F (903.4-1) is the panel in inches (mm), as defined in = ,2, ksi ksi (MPa) F a C y auf Where is the in inches (mm), as defined in (mm), e f (903.4-1) = , ksi F f 0 . 6 F (903.4-2) For ASD: div y e = /F’ for end panels For LRFD: f 0 . 9 F (903.4-1) f 0 . 6 F (903.4-2) For ASD: au div y = ksilength, (MPa) F m au 2)(MPa) e ((k f 0 . 6 F (903.4-2) For ASD: a .e9 F div y ng in For LRFD: f 0 (903.4-1) / r ) Where is the panel length, inches asdefin defin 0 . 6 F (903.4-2) For ASD: = , ksi (MPa) F 2 auf div y a div y e Where is the panel length, inininches (mm), For ASD: ( k / r k / r ) Q = form factor defined in Section 903.2(b) a div y (903.4-2) au div y 2 Where is the panel length, in inches (mm), in a div y isthe panel length, indefined inches (mm), defined ction ((/rkkrx))/Where 2xrxx )x rand ((kk/903.2(b) Section rx the isradius the radius of as gyration about theas as is of gyration about the Section 903.2(b) and / r ) x 2 2 C = 1 0.4 f /F’ for interior panels x m au e ed in Section 903.2(b) and r is the radius of gyration abot x and x Section 903.2(b) and r is the radius of gyration abou (903.4-2) For ASD: A = area of the top chord, in. (mm ) Section 903.2(b) r is the radius of gyration about the x Section 903.2(b) and r is the radius of gyration about x f 0 . 6 F (903.4-2) For ASD: f 0 . 6 F (903.4-2) For ASD: x (mm), div ff adiv (903.4-2) For Where the is the panel length, in inches (mm), as defined 6yy.6 (903.4-2) For axis of a f adiv div y0 aa ASD: Where is the panel length, in inches (mm), defined div Where the panel length, inches (mm), asas axisWhere of bending. Where is the panel in as in inin in 0minimum FF 0y y..66 F Fyy yield (903.4-2) For isbending. panel length, in inches (mm), as defined indefined FASD: =ASD: specified strength, ksi (MPa) axis f aof atop 0.top (903.4-2) For ASD: div ygyration Where isis the panel length, inininches inches (mm), as defined defined axis ofrlength, bending. div Where isis the panel length, in inches (mm), as defined in in the axis of bending. of bending. The radius the chord about its vertical axis of bending. The radius of gyration of the chord about its vertical ofThe radius of gyration of the top chord about its vertical axis Where ℓ the panel length, in inches (mm), as defined in Section 903.2(b) and is the radius of gyration about the radius of gyration about the Section 903.2(b), Section 903.2(b) risradius is of gyration about thethe radius gyration about Section 903.2(b) rxrthe xx is ofofradius gyration about the Section 903.2(b), and rand Theof radius ofgyration gyration ofthe the top chord about itsvertical vertical x and The radius of of chord about 2 top the radius of of gyration about the thethe Section 903.2(b), and The radius of gyration theof chord about its top vertical x isx radius The gyration of the chord about its its vertical gyration about the Section 903.2(b), andand rxisisthe axis shall not be radius less than /120 where istop spacing E axis of bending. axis of bending. axis shall not be less than /120 where iswhere the spacing in in shall notshall be less than ℓ/120 ℓthe is the spacing inisinches axis of bending. Section 903.2(b), and r is the radius of gyration about the Q = form factor defined in Section 903.2(b) axis of bending. axis of bending. x Q = form factor defined in Section 903.2(b) axis of bending. axis not be less than /120 where the spacing in axis of bending. axis shall not be less than /120 where is the spacing lyaxis by inches =form form factor defined in Section 903.2(b) shall not beradius less than /120 where chord ischord the spacing in The radius of gyration of the top chord about its =oflines ,the ksi (MPa) Fbetween The radius of gyration of the top about its vertical axis shall not less than /120 where vertical is vertical the spacing 2 2defined 2 in Section QQ=top =in 903.2(b) The of gyration of the top chord about its vertical egyration Q in =in form= factor defined Section 903.2(b) 2factor For ASD: The radius of gyration of about its vertical Q form factor 903.2(b) The radius of of the top chord about its vertical The radius of gyration of the top chord about its (mm) lines of bridging as specified inSection inches (mm) between ofbe bridging as specified in The radius gyration of top chord about its 2the area the chord, in.defined ) in Section (mm) between lines oftop bridging as specified invertical A in =A area of theof top chord, in. (mm ) top chord, axis bending. 22 2 22 2 of 2 (mm inches (mm) between lines of bridging as specified in 2in. inches (mm) between lines of bridging as specified inches (mm) between lines of bridging as specified in ction A = area the in. (mm ( k / r ) axis shall not be less than /120 where is the spacing in inches (mm) between lines of bridging as specified in axis shall not be less than /120 where is the spacing in A = area of the top chord, (mm )) A = area of the top chord, in. (mm ) Q = form factor defined in Section 903.2(b) axis shall not be less than /120 where is the spacing in A = area of the top chord, in. (mm ) x Q = form factor defined in Section 903.2(b) axis shall not be less than /120 where is the spacing in Section 904.5(d). Q = form factor defined in Section 903.2(b) axis shall not be less than /120 where is the spacing axis shall be less /120 where is the spacing in Section 904.5(d). axisnot shall not be than less than /120 where the spacing in in factor defined in Section 903.2(b) =form form factor defined 903.2(b) = =form factor defined Section QQ Q = form factor defined in Section 2 Section 2 903.2(b) 904.5(d). 2in in 2903.2(b) Section 904.5(d). inches (mm) between lines of bridging as specified in Section 904.5(d). (903.4-6) at the panel point: f f 0 . 6 F 2 2 Section 904.5(d). 2 2 inches (mm) between lines of bridging as specified in A = area of the top chord, in. (mm ) Section 904.5(d). 2(mm 2 )2 ofofthe top chord, in. )2(mm 2 abridging bof bridging yspecified inches (mm) between lines of in inches (mm) as specified inches (mm) between lines of bridging as specified inas A=area = the toptop chord, in. (mm =area of top chord, in. ) ) 2) AAA QA=A form factor defined in 903.2(b) inches (mm) between lines of bridging as specified in indefined in inches (mm) between lines oflines bridging asinches specified in Where isbetween the panel length, inas (mm), the top chord, in.Section (mm )(mm =area area of the chord, (mm == area area ofofthe the top chord, in.in. Section 904.5(d). Section 904.5(d). Section 904.5(d). Section 904.5(d). 2 2 904.5(d). The topSection chord shall be considered as stayed laterally by Section 904.5(d). Section 904.5(d). The top chord shall be considered as stayed laterally by is the radius of gyration about the Section 903.2(b) and r A = area of the top chord, in. (mm ) x For ASD: shall The toptop chord shall shall be considered as stayedby laterally by the For by ASD: The top chord beconsidered considered asstayed stayed laterally by The chord be as laterally The the top chord be considered as laterally mber For ASD: The top chord shallshall bestayed considered asSection stayed laterally byASD: ASD: For ForFor ASD: at the mid panel: roof deck provided the requirements ofSection the roof deck provided the requirements ofthe Section axis ofchord bending. The top shall be considered as stayed laterally by The top chord shall be considered as stayed laterally by roof deck provided the requirements of 904.9(c) For ASD: the roof deck provided requirements of Section For ASD: The top chord shall be considered as stayed laterally by the roof deck provided the requirements of Section the roof deck provided the requirements of Section shall The top chord shall be considered as stayed laterally by For ASD: the roof deck provided the requirements of Section ertical The top chord shall be considered as stayed laterally by For ASD: (903.4-6) at the panel point: 0 904.9(c) of this specification are met. For ASD: (903.4-6) at the panel point: f f panel 0f .6Fpoint: The top chord shall be considered as stayed laterally by The chord shall be considered as stayed laterally by the roof deck provided the requirements of Section 904.9(c) oftop this specification are met. fprovided the roof deck provided the requirements ofof Section For ASD: aat ba panel y .6 Fyf f f f For ASD: For ASD: the roof deck provided the requirements of Section (903. athis 904.9(c) of this specification are met. this specification are met. at the panel point: (903.4 at the specification roof deck the requirements Section the fthe 0f.b6 Fpoint: 6.y6FFy y 904.9(c) ofroof this are met. 904.9(c) of this specification are met. (903.4-6) atfpoint: panel point: fay a afb b b(903.4-6) 0(903.4-6) .600 F.(903.4-6) 904.9(c) of specification are met. athe bf y0.6 F the deck provided the requirements of Section for 0 . 2 ,defined ng in the at the panel 904.9(c) of this specification are met. at the panel point: f 0 . 6 F theroof roof deck provided the requirements of Section deck provided the requirements of Section 904.9(c) of this specification are met. Q = form factor in Section 903.2(b) a b (903.4-6) at panel the panel point: af fbfa f0 y0.6 Fy 904.9(c) of this specification are met. (903.4-6) at the point: . 6 F 904.9(c) of this specification are met. b F a f b f 0 2 2 (903.4-6) at the panel point: 904.9(c) of this specification areare ed The top chord shall be adesigned as a continuous member (903.4-6) at panel point: 0F.Fy6yFy (903.4-6) atmid thethe panel point: faa fa bfb fb y0.6 .6 904.9(c) of this met. 904.9(c) of this specification are met. Theintop chord shall be designed as amet. continuous member A =specification area ofshall the top chord, in. (mm ) a continuous at at the panel point: (903.4-6) the mid panel: at the panel: top The top chord be designed as a continuous member The top chord shall be designed ascontinuous member The top chord shall be designed as adesigned continuous member The top chord shall be designed as a continuous member The top chord shall be as a continuous member The top chord shall be designed as a member at the mid panel: The chord shall be designed as a continuous member at the mid panel: at the mid panel: subject to combined axial and bending stresses and shall at the mid panel: The top chord shall be designed as a continuous member at the mid panel: subject to combined axial and bending stresses and shall at the mid panel: The top chord shall be designed as a continuous member at the mid panel: subject to combined axial and bending stresses and shall at thefamid panel: fa subject to combined axial and bending stresses and shall beand subject to top combined axial and bending stresses and shall subject to combined axial and bending stresses shall subject to combined axial and bending stresses and shall subject tothat: combined axial and bending stresses and shall subject to combined axial and bending stresses and shall The chord shall be designed as a continuous member subject tothat: combined and stresses and sotop proportioned The top chord shall be designed as a continuous member for mid The chord designed as a bending continuous member fafor be sobe proportioned subject toshall combined axialaxial and bending stresses and shallshall at the mid 0.2 , for 0mid 0panel: .panel: 2,panel: f fafa at the -3) at the the mid panel: be sobe proportioned that: be so proportioned that: sosubject proportioned that: be so proportioned that: be so proportioned that: so proportioned that: for be so proportioned that: to combined axial and bending stresses and shall be so proportioned that: forfora 0.200.,2.2, , lybeby F be proportioned that: fffa.a2 , F subject to combined axial and bending stresses and shall subject toso combined and bending stresses and shall f For ASD:axial a a fa 0afa.a2 F for fa, ,000..22.2,, , Fa FF a for bebe so proportioned that: for ction for Fafor Fa0.2 For LRFD: so proportioned that: be so proportioned that: For LRFD: 0.,2 , a forfor 0.2 For LRFD: LRFD: For LRFD: F a For LRFD: For f C f 8 LRFD: For LRFD: For LRFD: F F a ForFor LRFD: For LRFD: a m (903.4-6) at panel point: a Fa F fba fbdiv 0.6 F the .0 (903.4-7) a a y1(903.4-3) at the panel point: For LRFD: ffau fau f0 0 ..67 9ff0bu F.fy9F00y at the panel point: f ..9 F (903.4-3) at the panel point: f . 9 F (903.4-3) 9 F at the panel point: f (903.4-3) bu au y For LRFD: au bu y For LRFD: 1 at the panel point: f 9 F (903.4-3) bu a at the panel point: f 0 . 9 F (903.4-3) at the panel at point: fthe panel fbupanel fpoint: 0 . 9 (903.4-3) the panel point: F fbu bu 0au .au 9 F (903.4-3) at the point: f f 0 . 9 F (903.4-3) au y0 a f bu y at point: au y f . 9 F (903.4-3) au y (903.4-3) at the panel bu y QFb y 1 au bu mber at the mid panel: at the panel point: f f 0 . 9 F (903.4-3) F au bu y e at panel point: fau 0.F9yFy (903.4-3) at the thethe panel point: fau fbufbu 0.9 Cm 88CfC shall div ffbdiv (903.4-3) at the mid panel: f mfC at panel: at mid bdiv Cfbffm at atmid the mid panel: bm C.C ffaa ff8aa8f affaa88C atthe the mid panel: 8div f 8mf bC m panel: at the mid panel: (903.4-7) f1.b011div f 8 b div (903.4-7) (903.4-7) at the mid panel: m at the the mid mid panel: panel: ..00div(903.4-7) 1 (903.4-7) ab div div f C a 8 div (903.4-7) at the mid panel: 11 a at thefor mid panel: F F9F9 9 a 1m.00fmbm (903. , (903.4-7) .0.b0 (903.4 (903.4-7) 011.0.0 (903.4-7) mf1F fau 0.f2 1. 1.aF .f67 a 991 F 1 ..f67 ffa . 67 f au a f C 8 67 f a a 9 F 9 9 F a f f at the mid panel: F f 1 67 a b div 9 F f a 1 . 67 f f 1 . 67 for, 0 . 2 , a af f C f a f a fau 8 C 1 . 67 f 8 9 F au au for, 0 . 2 , a 1 . 67 f 1 QF a f au a a 1 QF au a 1 QF a f mid panel: at at thethe mid panel: 1 . 67 f 1 . 0 (903.4-7) a m b div a m b div a a 1 QF a f for, for,au 0.200,.2.2, , 0 for , 0 a .0 , .2 ,for,for, bQF b b (903.4-7) b1 for au QF b1 bQF 1.0QF (903.4-7) 1 1 FF F 1 bQF forau for F..22cr0,, .c2 for 00.2 . 2 fF a999FF 1bFb FFeQF ffaFFbeef1 cc,0F 67 cFFcrccF e1ee.67 F Faa F e11.67 aucr Fcr cr fau fau 0.2, cF cF F e cF crcr . cr afor, e cr 1 QF c cr a 1 1 a QF b e -4) .2 0.,2 , for,for, F 0 QF faf ffaa FFeF bb c cr -3) 0 . 2 , for e e 0 . 2 , for a f cFccrFcr fafor F0a .2 ,0.2 , afor .2, , 0.2 , for forforfF fa fafa 00.2.2, , F0aa.2 Faa0 for for 0 . 2 , for F F f C f 8 ffau au 88 C f8 8div88CCm8divC ffaa f 1fC.bfff0bu 1f.div fCCbu a f au Fafor mmffffbubuaau mm fdiv f a fm div div(903.4-4) C .1(903.4-4) mC au C au8budiv div m ..22 , Fa FF (903.4-7) 0div a0 a ..00 1(903.4-4) au bubu (903.4-4) faufau bu div fau f mbubu 88 mC 11.0.01(903.4-4) . 0 (903.4-4) 10 (903.4-4) 0 .,2 , a for 0 for a mm1b.0 div div (903.4-4) 1 . 0 (903.4-4) (903.4-4) 9 F 1 . 0 (903.4-4) c F 9 9 F F 1 . 0 (903.4-8) f F 9 c f cr9 8 C f f 1 . 67 f cr F 9 a a f F au 9 F f c cr au m bu div cr9mcrfQbu9f9 FaFa faf1au.0QQF cr12cfcF 91 auauFC F (903.4-4) c cr f auf au 1 8 cc8 cC 1div Q fbdiv F F au FcrccrF (903.4-4) yffau m 11bubbF au Fcr bFy y(903.4-4) yyb F F 1 0 1Q 0QF bbQ Fy. f ffa Cm fCCm ffb div FaufQaQau1b.FQ 1.67 F 1yy1111au FbF 9 FaQ yQ Special Profile Joists SP-Series Design SP-Series Tables consideration, ksi (MPa) defined in Section 903.2.17 consideration, (MPa) consideration, ksiksi (MPa) M = required flexural strength using ASD load combinations, kip-in (N-mm) 3 3 88 a a defined in Section 903.2(b), ksi (MPa) 89 89 8989 Discover the easiest way to specify special profile joists: defined Section 903.2(b), (MPa) defined in in Section 903.2(b), ksiksi (MPa) www.newmill.com/digital-tools Standard Specification divdiv 1.0 (903.4-8) F c c crF eFe ebe bb y cF ec F ccFFF eecff auauefauQ cr 9 91cc F afa a C m bfbm bdiv e ccr ceF c F 11.0.0 1.0 (903.4-8) F (903.4-8) e (903.4-8) c e b y (903.4-8) Qb m1. Fby Fy fbfdivf11 mffC ff a 22fFaFa22FFCaC ..67 ffa 1 1c FeQ 67 div b 67 a C f a (903.4-8) 1 . 67 f f f c F C f a 1 . 0 a m 1 bf1 fdiv a QF F 1 . 0 (903.4-8) a m b div C f a QF a m b div .e2,fau b1m.QF 2F 1 1a F QF fau (903. fa,ceff0au 0bbb div (903.4-8) for (903.4 au f 1 011.0.0 (903.4-8) au 2 F f b 1 . 67 f 0 . 2 for au F f C f f au a 0 . 2 , for, 1 . 67 f aF , for,fau auau stress, for, 11.67 ksi (MPa) 2 Faa faf 1.67 fa = eediv .20, .2 0,0..22 ,compressive for 2C fmFaC 2FfFbeFaeaQF .(903.4-8) a crP/A, 0. 2 ,0Required for for 2 for, . 67 f f 0 . 2 , F f 1 QF 1 . 0 0 . 2 , for, F 1 a 1 . 67 f a m b div c a m b div a F 0 . 2 , for, a c F crc Fcr Fcr caxial FaccF a .0 P f cr strengthusing 2F1 F F bb111b 1 b b (903.4-8) QF 0QF (903.4-8) required bQF c cr = cF F ASD load 1.QF fcompressive F P/A, stress, stress, a for,cr faufau 0.2, c F == P/A, e 11..67 F -4) 67 required ksi (MPa) ffaF a crc crcr e.67 Feksi 2 required faf = 2 e compressive F e (MPa) 1 f P/A, required compressive stress, ksi (MPa) f F a 0 . 2 , a 0 . 2 , for,for, au 1 QF a combinations, kips (N) = P/A, required compressive stress, ksi (MPa) a e F ksiload b stress, fa a P ==P/A, (MPa) ausing QF Fcompressive using ASD QF Required stress 1required ASD axial strength load 1axial strength ccFccr b busing = required required axial ASD -5) required strength loadload e strength crFcrbending fb = M/S, at the location underPPfP =P=required using axial ASD ASD Required F F = P/A, compressive stress, ksi (MPa) combinations, kips (N) = required axial strength using load = P/A, Required compressive stress, ksi (MPa) f a combinations, kips (N) e e a (N) Required stress, ksi (MPa) fa = P/A,combinations, combinations, kips fa fafcompressive compressive P/A, Required compressive stress, ksi(MPa) (MPa) (N) C fCCm ff ksi a=kips ==strength P/A, Required compressive stress, (MPa) P/A, Required stress, ksiksi (MPa) ffau consideration, f au = M/S, required bending stress at the location under b M/S, P = required axial using ASD load fb= =ff= required bending stress at the location under bu div P = required axial strength using ASD load m combinations, kips (N) bu div C f = M/S, required bending stress at the location under f b m P required axial strength using ASD load f M/S, required bending stress at the location under au bu div au f =Divergence bfa m P = required axial strength using ASD load 1 . 0 (903.4-5) = P/A, Required compressive stress, ksi (MPa) σ bu div 1 . 0 (903.4-5) P = required axial strength using ASD load P = required axial strength using ASD load 1.0(903.4-5) consideration, ksi (MPa) applicable divapplied 1.01where (903.4-5)as (903.4-5) ksi (MPa) combinations, kips (N)stress atstress, mffstress = P/A, Required compressive stress, (MPa) ==required P/A, Required compressive ksiksi (MPa) combinations, kips (N) consideration, ksi (MPa) b ksi(N) (MPa) 22div cffa C F fa consideration, M/S, required bending the location under kips ffbudivdivCfau buFcr f ffau f au 22cC m combinations, kips (N) .0 (903.4-8) fPfbacombinations, cFFcr =consideration, axial strength using ASD load combinations, kips (N) C C au m f combinations, kips (N) C σ = divergence stress applied where applicable as c cr fdiv m bu div f C f 1 . 0 (903.4-5) σ = divergence stress applied where applicable as au au cr defined in Section 903.2.17 f = M/S, Required bending stress at the location under div 1 Q F 1 . 0 (903.4-5) au m bu div P = required axial strength using ASD load f f P = required axial strength using ASD load f = M/S, Required bending stress at the location under b au σ = divergence stress applied where applicable as 1 Q F au m bu div b 2 F div 1 . 0 (903.4-5) fb = M/S, Required stress at the location under σdiv = divergence applied where applicable asstress consideration, (MPa) (903.4-5) fbending M/S, Required bending stress the location u Fyy using aCau ff11F1.67 Fyybbdiv b Q combinations, kips (N) mFfQbuabstrength (903.4-5) b= M/S, fbstress ==ksi M/S, Required bending atatthe location un fF M 1.ASD 011.0.0 load (903.4-5) Required bending stress at the location unde bEquation defined in Equation 903.2-17 crcr2 defined infin 903.2-17 F f = required flexural consideration, ksi (MPa) 1 QF 22cc F c e m bu div combinations, kips (N) combinations, kips (N) consideration, ksi (MPa) au F 2 F f defined in Equation 903.2-17 c e au b F 2 F consideration, ksi (MPa) defined Equation 903.2-17 cf auaucrfau1 f c e c cr au C f C f 2 F 1 . 0 (903.4-5) f consideration, ksi (MPa) 1 Q F f = M/S, Required bending stress at the location under σ = divergence stress applied where applicable as c cr c e Q F au div b consideration, ksi (MPa) f m bu div m bu div c cr au b y = required flexural strength using load au 1.01(N-mm) consideration, ksi ASD (MPa) MMσ =fM required flexural strength using ASD load bbyy111Fekip-in 0Q b Fy(903.4-5) 2c Fcr Fcombinations, M = required flexural strength using ASD load = M/S, Required bending stress at the location under bQ = M/S, Required bending stress at the location b= Divergence stress applied where applicable asunder y (903.4-5) = required flexural strength using ASD load Fyb F σdiv Divergence stress where applicable as div stress, fFaue compressive Q div compressive F=fauPu/A, crequired σ ==fbDivergence stress where applicable as .stress, consideration, ksi (MPa) 3(MPa) 3 1PP defined inσdiv Equation 903.2-17 combinations, kip-in (N-mm) c F FF =applied Divergence stress applied where applicable as = ksi (MPa) cc required ee combinations, kip-in (N-mm) divDivergence u/A, σ =applied Divergence stress applied where applicable ksi F σ = stress applied where applicable as as e combinations, kip-in (N-mm) f f Q = /A, required compressive stress, ksi (MPa) f S = elastic Section Modulus, in (mm ) c cr cr div 2f2caufF c e au u consideration, ksi (MPa) combinations, kip-in (N-mm) consideration, ksi (MPa) 3 3 = P /A, required compressive stress, ksi (MPa) au f = P /A, required compressive stress, ksi (MPa) b y au c e au 3 3 required strength auu= 1 u axial defined in Section 903.2.17 Q load 3where 3) applicable as defined inSection Section 903.2.17 S = elastic Section Modulus, in (mm 1 Q F P using LRFD F 3(mm 3 ASD defined in Section 903.2.17 S = elastic Modulus, in ) urequired σ = Divergence stress applied P axial strength using LRFD load F M = required flexural strength using load div u = b y b y defined in Section 903.2.17 S = elastic Section Modulus, in (mm ) P = required axial strength using LRFD load = P/A, Required compressive stress, ksi (MPa) f c e defined in Section 903.2.17 compressive kips allowable = div elastic Section Modulus, inapplied (mm ) where =uRequired required strength using LRFD load a = nder f defined in Section 903.2.17 axial stress based on /rMas S=M ksi compressive σ = Divergence stress applicable σrequired = Divergence stress applied where applicable asas F P required axial strength using LRFD load axial required flexural strength using ASD load div = PPuu/A, ksi (MPa) uFa= required flexural strength using ASD load (N) (MPa) fau Required = allowable axial compressive stress based on /r as F= e combinations, c Fce kips Required kips M flexural strength using ASD load axial compressive stress based on as F= compressive stress, ksi (MPa) =defined (N) au =auPuu/A, Required combinations, kips (N) =combinations, compressive faufau stress, defined in 903.2.17 required flexural strength using ASD load =combinations, allowable axial compressive stress based on /rASD asASD (N-mm) = Pu/A, /A, compressive stress, ksi(MPa) (MPa) combinations, (N) P = required axial strength using ASD load MM=Section ==kip-in required flexural strength using load uRequired allowable axial compressive stress based on/r /r as Fa a =F=aaallowable Prequired stress, ksi M required flexural strength using load in Section 903.2(b), ksi (MPa) P /A, compressive stress, ksi (MPa) f au u f = M /S, bending stress at the location under combinations, kip-in (N-mm) P = required axial strength using LRFD load defined in Section 903.2(b), ksi (MPa) bu u defined in Section 903.2.17 combinations, kips (N) defined in Section 903.2.17 fbu = MMu/S, required bending stress atatthe location under combinations, kip-in (N-mm) Puu =f urequired axial strength load defined ininSection 903.2(b), ksi (MPa) combinations, kip-in (N-mm) using LRFD load f= = M /S, required bending stress at the location under 3using 3(MPa) defined in Section 903.2(b), ksi buRequired urequired fbuu/A, /S, bending stress the location under M = required flexural strength ASD load combinations, kip-in (N-mm) compressive stress, ksi (MPa) = required axial strength using LRFD load defined Section 903.2(b), ksi (MPa) uP 3 3 combinations, kips (N) combinations, kip-in (N-mm) S = elastic Section Modulus, in (mm ) au = P u P = required axial strength using LRFD load 3 3 u combinations, kip-in (N-mm) 3 3 P = required axial strength using LRFD load consideration, ksi (MPa) u= consideration, ksi Section Modulus, inusing (mm )ASD kips (N) M== elastic = required flexural strength load required flexural strength ASD load elastic Section Modulus, in (mm ) Modulus, = Required compressive stress, fau= combinations, PuP /A, Required compressive stress, ksi (MPa) combinations, kips (N) consideration, ksi (MPa) f MuM/S, /S, required bending stress atksi the(MPa) location under under u/A, SS ==SMelastic Section Modulus, in (mm )using au bu 3 3)3) ksi(MPa) (MPa) (N-mm) elastic Section in3 3(mm (mm strength using LRFD load combinations, kips (N) -5) fP fconsideration, = Required bending stress at the location u = required ==kip-in elastic Section Modulus, combinations, kips (N) b axial FFa == combinations, combinations, allowable axial compressive stress based ℓ/r as S SS= elastic Section inon3in(mm ) as combinations, kips (N) 3 Modulus, 3 based f = M /S, Required bending stress at the location under combinations, kip-in (N-mm) kip-in (N-mm) P = required axial strength using LRFD load allowable axial compressive stress on /r P = required axial strength using LRFD load fbu = M /S, Required the location under bu u u = allowable axial compressive stress based on /r as F a u u bending stress at the location under consideration, ksi (MPa) a =Sallowable axial stress based Funder bu u = elastic Section Modulus, in (mm )3 3on /r as aunder combinations, kips (N) fbu =uM Mu/S, /S, Required bending stress atthe the location consideration, ksi (MPa) =allowable allowable axial compressive stress based on/ Facompressive uRequired 3compressive f = Required bending stress at location 3compressive a allowable = axial stress based F bu f = M /S, bending stress at the location under defined in Section 903.2(b), ksi (MPa) = axial stress based onon /r a F bu a ksi (MPa) S = defined = elastic Modulus, inksi (mm Sdefined elastic Section Modulus, in (mm ) ) kips inSection Section 903.2(b), (MPa) combinations, kips (N)(N)stressksi consideration, defined inSection Section 903.2(b), ksi (MPa) ksi (MPa) in 903.2(b), ksi (MPa) fbu = consideration, Mucombinations, /S, σ Required bending at the location under consideration, (MPa) = allowable axial compressive stress based on /r as F defined in Section 903.2(b), ksi (MPa) a consideration, ksi (MPa) defined in Section 903.2(b), ksi (MPa) = Divergence stress applied where applicable as consideration, ksi (MPa) div defined in Sectionstress 903.2(b), ksion (MPa) Required bending stress location under fbufbu= = MuM /S, Required bending stress at at thethe location under allowable axial compressive stress based on allowable axial compressive based /r/r asas u/S, FF == 93 Introduction STANDARD SPECIFICATION, SP-SERIES Fb = 0.6 Fy, allowable bending stress, ksi (MPa) Cm = 1 - 0.5 fa/Fe for end panels Cm = 1 - 0.67 fa/Fe for interior panels (b)Web The vertical shears to be used in the design of the web members shall be determined from full uniform loading, but such vertical shears shall be not less than 25 percent of the end reaction. Special Profile Joists Interior vertical web members used in modified Warren-type web systems shall be designed to resist the gravity loads supported by the member plus an additional axial load of 1/2 of 1 percent of the top chord axial force. (c) Eccentricity Members connected at a joint shall have their center-of-gravity lines meet at a point, if practical. Eccentricity on either side of the neutral axis of chord members may be neglected when it does not exceed the distance between the neutral axis and the back of the chord. Otherwise, provision shall be made for the stresses due to eccentricity. Ends of joists shall be proportioned to resist bending produced by eccentricity at the support. SP-Series Design (d) Extended Ends Extended top chords or full depth cantilever ends require the special attention and coordination between the specifying professional and NMBS. The magnitude and location of the loads to be supported, deflection requirements, and proper bracing shall be clearly indicated in the contract documents and joist erection plans. 903.5 CONNECTIONS (a) Methods SP-Series Tables Joist connections and splices shall be made by attaching the members to one another by arc or resistance welding or other accredited methods. Standard Specification (1) Welded Connections a)Selected welds shall be inspected visually by the manufacturer. Prior to this inspection, weld slag shall be removed. b) Cracks are not acceptable and shall be repaired. c) Thorough fusion shall exist between weld and base metal for the required design length of the weld; such fusion shall be verified by visual inspection. d) Unfilled weld craters shall not be included in the design length of the weld. e) Undercut shall not exceed 1/16 inch (2 mm) for welds oriented parallel to the principal stress. f) The sum of surface (piping) porosity diameters shall not exceed 1/16 inch (2 mm) in any 1 inch (25 mm) of design weld length. g) Weld spatter that does not interfere with paint coverage is acceptable. 94 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools (2) Welding Program NMBS shall have a program for establishing weld procedures and operator qualification, and for weld sampling and testing. (Refer to Steel Joist Institute Technical Digest #8, Welding of Open Web Steel Joists.) (3) Weld Inspection by Outside Agencies (See Section 904.13 of this specification). The agency shall arrange for visual inspection to determine that welds meet the acceptance standards of Section 903.5(a)(1). Ultrasonic, X-ray, and magnetic particle testing are inappropriate for joists due to the configurations of the components and welds. (b) Strength (1) Joint Connections shall develop the maximum force due to any of the design loads, but not less than 50 percent of the strength of the member in tension or compression, whichever force is the controlling factor in the selection of the member. (2) Shop Splices may occur at any point in chord or web members. Splices shall be designed for the member force but not less than 50 percent of the member strength. Members containing a butt weld splice shall develop an ultimate tensile force of at least 2 x 0.6 Fy times the full design area of the chord or web. The term “member” shall be defined as all component parts comprising the chord or web, at the point of splice. (c) Field Splices Field Splices shall be designed by NMBS in accordance with the AISC Steel Construction Manual. Splices shall be designed for the member forces, but not less than 50 percent of the member strength. Top chord splices may be designed as “compression only” when the joist is not subject to an in-service net uplift. Most all joists are subject to negative bending moment during hoisting at erection and “compression only” splices shall be designed for these tension forces. 903.6 CAMBER SP-Series joists are furnished with no camber. NMBS can provide special camber as required by the contract documents. The specifying professional shall give consideration to coordinating joist elevation with adjacent framing. Technical performance requirements shall be coordinated between NMBS and the specifying professional. 903.7 VERIFICATION OF DESIGN & MANUFACTURE (a) Design Calculations Design calculations prepared by a professional engineer registered in the state of the NMBS manufacturing plant are available for NMBS SP-Series joists upon request. STANDARD SPECIFICATION, SP-SERIES Introduction 904.1 USAGE This specification shall apply to any type of structure where roof 904.1 USAGE decks are to be supported directly by SP-Series joists installed Special Profile Joists This specification applyWhere to any type of joists structure where as hereinaftershall specified. SP-Series are used other roof decks aresimple to bespans supported directly bydistributed SP-Series joists as than on under uniformly loading installed as hereinafter specified. Where SP-Series joists are prescribed in Section 903.1, they shall be investigated and used other than on simple spans under uniformly distributed if necessaryinto Section limit the 903.1, requiredthey stresses to those loadingmodified as prescribed shall be listed inand Section 903.2. if necessary to limit the required investigated modified stresses to those listed in Section 903.2. CAUTION: If a rigid connection of the bottom chord is to be CAUTION: connection of the bottom chord to be made Ifto atherigid column or other support, it shall be madeisonly after made the to the column oforthe other it shall made application deadsupport, loads. The joist be is then no only longer after the application of the dead loads. The joist is then no simply supported, and the system must be investigated for longer simply supported, and the system must be investigated continuous frame actionbybythe thespecifying specifyingprofessional. professional. for continuous frame action The designed a rigid-type connection moment The designed detaildetail of a of rigid-type connection andand moment plates plates shall shall be shown on inthe drawings and by on thethe be shown the structural contract documents specifying professional. moment plates shall be The furnished structural drawingsThe by the specifying professional. moment by other thanshall NMBS. plates be furnished by other than NMBS. 904.2 SPAN 904.2 SPAN SP-Series Design The “span” term “span” as used herein is defined as shown The term as used herein is defined as shown on on thethe diagram at theatright. On beams, thethe span diagram the right. On beams, spanisistotothe thecenter center line of of the the supporting steel span isisdefined definedasas supporting steeland andon on aa wall, wall, span 6” 6” (152 (152 mm) over the support. In each case, the vertical location mm) over the support. In each case, the vertical location of of the point for determining span is at the top of the joist topthe chord. point for determining span is at the top of the joist top chord. the bearing a SP-Series different When When the bearing pointspoints of a of SP-Series joistjoist areare at at different elevations, the span of the shallshall be determined by by thethe elevations, the span of joist the joist be determined length length along along the slope. the slope. In all cases, the design length of the is equal to the span In all cases, the design length of joist the joist is equal to the span less 4” (102 mm). less 4” (102 mm). 904.3 DEPTH SP-Series Tables 904.3 DEPTH The nominal depth as specified in the designation of SP-Series The nominal depth as specified in the designation of SPjoists shall the maximum depth of the depth joist as Seriesbejoists shall be the maximum of measured the joist as between the top and bottom chords. When joist geometry measured between the top and bottom chords. When joist consists of parallel chords, (e.g. Scissor or Arch), the geometryshall consists of parallel chords, (e.g.to Scissor Arch), measurement be made perpendicular the topor and measurement shallnot be prescribing made perpendicular and bottomthe chord. If a profile to one to of the thetop four types or variations catalog is used, to the depth bottom chord. Ifinathis profile not conforming onenominal of the four types shall be measuredin this perpendicular to athe chord tangent, at abe or variations catalog is used, nominal depth shall discontinuous panel point, (i.e. top or bottom chord ridge), or at measured perpendicular to a chord tangent, at a discontinuous the greatest nominal depth along the span. In any case, panel to point, bottomshall chordberidge), or at the in greatest dimensions be (i.e. usedtopinordesign as specified the nominal depth along the span. In any case, dimensions to be contract documents. used in design shall be as specified in the contract documents. Standard Specification SP-Series joists may have various chord configurations and may have bearing conditions thatvarious cause the pitch in SP-Series joists may have chordexcessive configurations and the chords. Thebearing designconditions of the joist all the cases shall be may have that in cause excessive pitch comprehensive to meet all design requirements set forth in the in documents. the chords. The design of the joist in all cases shall be contract comprehensive to meet all SP-Series design requirements set forth in the contract documents. Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 91 95 Introduction STANDARD SPECIFICATION, SP-SERIES 904.4 END SUPPORTS (a) Masonry and Concrete Special Profile Joists SP-Series joists supported by masonry or concrete are to bear on steel bearing plates and shall be designed as steel bearing. Due consideration of the end reactions and all other vertical or lateral forces shall be taken by the specifying professional in the design of the steel bearing plate and the masonry or concrete. The ends of SP-Series joists shall extend a distance of not less than 6 inches (152 mm) over the masonry or concrete support and be anchored to the steel bearing plate. The plate shall be located not more than 1/2 inch (13 mm) from the face of the wall and shall not be less than 9 inches (229 mm) wide perpendicular to the length of the joist. The plate is to be designed by the specifying professional and shall be furnished by other than NMBS. (c) Bridging Types For spans less than or equal to 20 feet (6.096 m), welded horizontal bridging may be used. If the joist center of gravity is above the supports, the row of bridging nearest the center is required to be bolted diagonal bridging. For spans more than 20 feet (6.096 m) all rows shall be bolted diagonal bridging. Where the joist spacing is less than 2/3 times the joist depth at the bridging row, both bolted diagonal bridging and bolted horizontal bridging shall be used. (d) Quantity and Spacing The maximum spacing of lines of bridging shall not exceed the values in Table 904.5-1. TABLE 904.5-1 Where it is deemed necessary to bear less than 6 inches (152 mm) over the masonry or concrete support, special consideration is to be given to the design of the steel bearing plate and the masonry or concrete by the specifying professional. The joists must bear a minimum of 4 inches (102 mm) on the steel bearing plate. SP-Series Design (b) Steel Due consideration of the end reactions and all other vertical and lateral forces shall be taken by the specifying professional in the design of the steel support. The ends of SP-Series joists shall extend a distance of not less than 4 inches (102 mm) over the steel supports for top chords less than angle size L5” x 5” x ½”, otherwise 6 inches (153mm). 904.5 BRIDGING SP-Series Tables Top and bottom chord bridging is required and shall consist of one or both of the following types. (a) Horizontal Horizontal bridging shall consist of continuous horizontal steel members with a ℓ/r ratio of the bridging member of not more than 300, where ℓ is the distance in inches (mm) between attachments and r is the least radius of gyration of the bridging member. (b) Diagonal Standard Specification Diagonal bridging shall consist of cross-bracing with a ℓ/r ratio of not more than 200, where ℓ is the distance in inches (mm) between connections and r is the least radius of gyration of the bridging member. Where cross-bracing members are connected at their point of intersection, the ℓ distance shall be taken as the distance in inches (mm) between connections at the point of intersection of the bridging members and the connections to the chord of the joists. 96 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools BRIDGING SPACING AND FORCES TOP CHORD MAXIMUM NOMINAL LEG SIZE BRIDGING FORCE SPACING REQUIRED < 2” 11’-0” 400 lbs. 2” 12’-0” 550 lbs. 2½” 13’-0” 750 lbs. 3” 16’-0” 950 lbs. 3½” 16’-0” 1300 lbs. 4” 21’-0” 1850 lbs. 5” 21’-0” 2300 lbs. 6” x 6” x 0.500” 26’-0” 2800 lbs. 6” x 6” x 0.625” 30’-0” 3450 lbs. 6” x 6” x 0.75” 30’-0” 4050 lbs. Nominal bracing force is unfactored. 8” chords – contact NMBS (e) Connections Connections to the chords of the steel joists shall be made by positive mechanical means or by welding, and capable of resisting a horizontal force not less than that specified in Table 904.5-1. (f) Bottom Chord Bearing Joists Where bottom chord bearing joists are utilized, a row of diagonal bridging shall be provided near the support(s). This bridging shall be installed and anchored before hoisting cables are released. STANDARD SPECIFICATION, SP-SERIES Bridging shall support the top and bottom chords against lateral movement during the OF construction period and shall hold the 904.6 INSTALLATION BRIDGING steel joists in the approximate position as shown on the joist Bridging shall support the top and bottom chords against placement plans. lateral movement during the construction period and shall hold the steel joists in the approximate position as shown on the Theplacement ends of all plans. bridging lines terminating at walls or beams shall joist be anchored to resist the nominal force shown in Table 904.5-1. The ends of all bridging lines terminating at walls or beams shall be anchored to resist the nominal force shown in Table 904.7 BEARING SEAT ATTACHMENT 904.5-1. with fixed anchorage conditions may induce a horizontal thrust to the supporting CAUTION: Scissor and Arch joists with anchorage structure. The specifying professional shallwelded give consideration conditions mayat induce horizontal to the supporting to this thrust the fixeda ends of the thrust joist. Alternatively, roller structure. The specifying professional shall give consideration (slip) end supports result in lateral displacement of the reaction to this thrust at the fixed ends of the joist. Alternatively, roller at theend roller (slip) end ofinthe joist.displacement Anchorage conditions must (slip) supports result lateral of the reaction atberoller (slip) end thespecifying joist. Anchorage conditions be investigated byofthe professional and themust design investigated by the specifying professional and theappropriate design of of the supporting structure shall accommodate the supporting structure shall accommodate appropriate anchorage conditions. anchorage conditions. the specifying professional on the contract documents. 904.8 JOIST SPACING Where uplift forces are a design consideration, SP-Series joists shall be anchored to resist such forces (Refer to Section Joists shall be spaced so that the loading on each joist does 904.12 Uplift). not exceed the design load (LRFD or ASD) for the particular joist as designated in the contract documents. 904.8 JOIST SPACING 904.9 ROOF DECKS Joists shall be spaced so that the loading on each joist does not (a) the Material exceed design load (LRFD or ASD) for the particular joist as designated in the contract documents. Roof decks may consist of gypsum, formed steel, wood, or other suitable material capable of supporting the required loadDECKS at the specified joist spacing. 904.9 ROOF (a) Material (b) Bearing Roof Decks decks may of gypsum,along formed wood, orof the shallconsist bear uniformly thesteel, top chords otherjoists. suitable material capable of supporting the required load at the specified joist spacing. (c) Attachments (b) Bearing The spacing of attachments along the joist top chord shall not exceed 36 inches (914 mm). Such attachments of the Decksdeck shalltobear the shall top chords of the of joists. the uniformly top chordalong of joists be capable resisting the forces given in Table 904.9-1. (c) Attachments TABLE 904.9-1 SP-Series Design For For applicable applicable conditions, conditions, horizontal horizontal thrust thrust force force to to be be resisted resisted by bythe the joist joistoror allowable allowablelateral lateralslip slipatatthe thesupport support and and design design details of end anchorage conditions shall be clearly indicated details of end anchorage conditions shall be clearly indicated by by the specifying professional in the contract documents. joists shall be anchored to resist such forces (Refer to (c) UpliftSection 904.12 Uplift). Special Profile Joists CAUTION: Scissor Arch joists 904.7 BEARING SEATand ATTACHMENT thereto with minimum of two 1/4 inch fillet welds, 4 inches long, or two 3/4 inch ASTM A325 bolts or equivalent. When SP-Series joists are used to provide lateral stability to the Uplift supporting member, the final connection shall be made by welding or as designated by the specifying professional.SP-Series Where uplift forces are a design consideration, Introduction 904.6 INSTALLATION OF BRIDGING The spacing of attachments along the joist top chord shall DECK FORCES of the not exceed 36 inches (914ATTACHMENT mm). Such attachments deck toTOP the top chordLEG of joists NOMINAL shall be capable of REQUIRED resisting CHORD FORCE the forces given in Table 904.9-1. ≤2” 100 PLF TABLE 904.9-1 2½” 150 PLF 3” Ends joists resting on steel bearing plates on Ends of SP-Series SP-Series joists on masonry structuralconcrete concrete shall be attached thereto masonry ororstructural shall be attached thereto with with a minimum of two 1/4 inch (6 mm) fillet welds 2 a minimum of two 1/4orinch (6 two mm)3/4 fillet welds inches (51 inches (51 mm) long, with inch (19 2mm) ASTM mm) long, or with two 3/4 inch (19 mm) ASTM A307 bolts A307 bolts (minimum), or the equivalent. (minimum), or the equivalent. Top chords of angle size L5” x (b) Steel 5” x 1/2” or greater shall be attached thereto with minimum of twoof1/4 inch fillet welds, 4 inches long,supports or two 3/4 Ends SP-Series joists resting on steel shallinch be ASTM A325 bolts or equivalent. attached thereto with a minimum of two 1/4 inch (6 mm) welds 2 inches (51 mm) long, or with two 3/4 inch (19 mm) ASTM A307 bolts (minimum), or the equivalent. Top chords of angle size L5” x 5” x 1/2” or greater shall be attached ≤2” 5” 6” x 6” x 0.500” 2½” 6” x 6” x 0.625” 3”6” x 6” x 0.75” 3½” 4” 5” 400 PLF NOMINAL FORCE REQUIRED 500 PLF 100 PLF 600 PLF 150 PLF 750 PLF 200 PLF 850 PLF Nominal bracing force unfactored. 200isPLF 8” chords – contact NMBS (d) Wood Nailers 300 PLF 400 PLF Where wood nailers are used, such nailers in conjunction 6” xwith 6” x deck 0.500”shall be firmly attached 500toPLF the top chords of the joists in conformance with Section 904.9(c). 6” x 6” x 0.625” 600 PLF 6” x 6” x 0.75” 700 PLF Nominal bracing force is unfactored. 8” chords – contact NMBS Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 93 97 Standard Specification fillet welds 2 inches (51 mm) long, or with two 3/4 inch (19 (b) mm) Steel ASTM A307 bolts (minimum), or the equivalent. When SP-Series joists are used to provide lateral stability to theofsupporting the on final connection Ends SP-Series member, joists resting steel supports shall shall be be made by welding or as designated by the specifying attached thereto with a minimum of two 1/4 inch (6 mm) fillet professional. 4” TOP CHORD LEG SP-Series Tables (a) (a) Masonry Masonry and and Concrete Concrete 200 PLF DECK 3½” ATTACHMENT FORCES 250 PLF Introduction STANDARD SPECIFICATION, SP-SERIES (d) Wood Nailers Where wood nailers are used, such nailers in conjunction with deck shall be firmly attached to the top chords of the joists in conformance with Section 904.9(c). 904.10 DEFLECTION 905.1 STABILITY The deflection due to the design live or snow load shall not exceed the following: • 1/360 of span where a plaster ceiling is attached or suspended When it is necessary for the erector to climb on the SP-Series joists, extreme caution must be exercised since unbridged joists may exhibit some degree of instability under the erector’s weight. The degree of instability increases for geometries common with SP-Series joists due to their higher center-of-gravity. • 1/240 of span for all other cases (a) Stability Requirements Special Profile Joists Roofs: (1) Before an employee is allowed on the SP-Series joists: BOTH ends of joists at columns (or joists designated as column joists) shall be attached to its supports. For all other joists a minimum of one end shall be attached before the employee is allowed on the joist. The attachment shall be in accordance with Section 904.7. The specifying professional shall give consideration to the effects of deflection. 904.11 PONDING The ponding investigation shall be performed by the specifying professional. Refer to Steel Joist Institute Technical Digest #3, Structural Design of Steel Joist Roofs to Resist Ponding Loads and AISC Steel Construction Manual. When a bolted seat connection is used for erection purposes, as a minimum, the bolts must be snug tightened. The snug tight condition is defined as the tightness that exists when all plies of a joint are in firm contact. This may be attained by a few impacts of an impact wrench or the full effort of an employee using an ordinary spud wrench. SP-Series Design 904.12 UPLIFT Where uplift forces due to wind are a design requirement, these forces must be indicated in the contract documents in terms of NET uplift in pounds per square foot (Pascals). The contract documents shall indicate if the net uplift is based upon LRFD or ASD. When these forces are specified, they must be considered in the design of joists and/or bridging. A single line of bottom chord bridging must be provided near the first bottom chord panel points whenever uplift due to wind forces is a design consideration. Refer to Steel Joist Institute Technical Digest #6, Structural Design of Steel Joist Roofs to Resist Uplift Loads. (2) For SP-Series joists with spans less than or equal to 20 feet (6.096 mm) that are permitted to have horizontal bridging per the restrictions of Section 904.5.(c), only one employee shall be allowed on the joists unless all bridging is installed and anchored. SP-Series Tables 904.13 INSPECTION Joists shall be inspected by NMBS before shipment to verify compliance of materials and workmanship with the requirements of these specifications. If the buyer wishes an inspection of the steel joists by someone other than NMBS, they may reserve the right to do so in their “Invitation to Bid” or the accompanying “Job Specifications.” Arrangements shall be made with NMBS for such inspection of the joists at the manufacturing facility by the buyer’s inspectors at buyer’s expense. (3) For SP-Series joists with spans more than 20 feet (6.096m), the following shall apply: a) All rows of bridging shall be bolted diagonal bridging. Where the joist spacing is less than 2/3 times the joist depth at the bridging row, both bolted diagonal bridging and bolted horizontal bridging shall be used. b) Hoisting cables shall not be released until all bolted bridging is installed and anchored, unless an alternate method of stabilizing the joist has been provided. c) No more than one employee shall be allowed on these spans until all bridging is installed and anchored. Standard Specification (4) When permanent bridging terminus points cannot be used during erection, additional temporary bridging terminus points are required to provide lateral stability. 98 Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools STANDARD SPECIFICATION, SP-SERIES (6) After the joist is straightened and plumbed, and all bridging is completely installed and anchored, the ends of the joists shall be fully connected to the supports in accordance with Section 904.7. (b) (b) Landing and Placing Loads Landing and Placing Loads bearing seats are attached. (2) During the construction period, loads placed on the SP-Series joists shall be distributed so as not to (2) During the construction period, loads placed on exceed the capacity of the joists. (3) the SP-Series joists shall be distributed so as not to exceed the joists. of joist bridging shall not Thecapacity weight of ofthe a bundle exceed a total of 1000 pounds (454 kilograms). The bundle of joist bridging shall be placed on a (3) The weightofof 3a bundle of joist bridging shall notatexceed minimum steel joists that are secured one a total 1000edge pounds kilograms).bundle The bundle end. ofThe of (454 the bridging shall of bejoist positioned within 1 foot on (0.30 m) of theofsecured end.joists bridging shall be placed a minimum three steel A copy of the OSHA Steel Erection Standard §1926.757, Open Web Steel Joists, may be found at www.newmill.com for reference. Qualified person is defined therein as “one who, by possession of a recognized degree, certificate, or professional standing, or who by extensive knowledge, training, and experience, has successfully demonstrated the ability to solve or resolve problems relating to the subject matter, the work, or the project.” (2) (c) Field FieldWelding Welding (c) All field welding be performed in accordance (1)(1)All field welding shallshall be performed in accordance with with the contract documents. Field welding shall not the contract documents. Field welding shall not damage damage the joists. the joists. (2) On cold-formed members whose yield strength has been attained by cold working, and whose as(2) On cold-formed members whose yield strength has been formed strength is used in the design, the total attained by cold working, as-formed strength length of weld at any and one whose point shall not exceed 50 is used in theofdesign, the totaldeveloped length of weld at any percent the overall width of one the section. pointcold-formed shall not exceed 50 percent of the overall developed width of the cold-formed section. (d) Handling Particular attention should be paid to the erection of SP(d) Handling Series joists. Care shall be exercised at all times to avoid (4)a) No The bundlecontractor of deck may be placed on SP-Seriesfrom joistsauntil has first determined (2) “qualifiedhas person” and documented a siteall bridging been installed and anchoredin and all joist specific erection plan that the structure or portion bearing ends attached, unless the following conditions of the structure is capable of supporting the load. are met: paragraphs 2 and 3, must be braced anchored to prevent lateral Each joist shall be adequately laterally before any movement. loads are applied. If lateral support is provided by bridging, the lines,Systems as defined in Section 905.1(a)(2) and 905.1(a) (e) bridging Fall Arrest (3), must be anchored to prevent lateral movement. the following conditions are met: b) The bundle of decking is placed on a minimum of 3 steel joists. has first determined from a “qualified a) The contractor (2) and documented a site specific erection c) person” The joists supporting theinbundle of decking areplan attached at both or ends. that the structure portion of the structure is capable of d) supporting All rows ofthe bridging load. are installed and anchored. e)b) The The total weight of the decking does not exceed bundle of decking is placed on a minimum of three 4000 pounds (1816 kilograms). bridging lines, as defined in Section 905(a), SP-Series joists shall not be used as anchorage points for a fall arrest system unless written direction to do so is (e) Fall Arrestfrom Systems obtained a “qualified person.”(2) SP-Series joists shall not be used as anchorage points for a fall arrest system unless written direction to do so is obtained from a “qualified person.”(2) steel joists. The edge of the bundle of decking shall be SP-Series Tables f) the SP-Series Design that are secured at one end. The edge of the bridging No bundle of deck may be placed on SP-Series bundle shall be within 1 foot (0.30 m)and of the joists until all positioned bridging has been installed secured end. anchored and all joist bearing ends attached, unless damage toattention the joists should and accessories. Particular be paid to the erection of SP-Series joists. Care shall be exercised at all times to Each joist shall be adequately braced laterally before any avoid damage to theIfjoists and accessories. loads are applied. lateral support is provided by bridging, (4) Special Profile Joists stated in paragraph 905(b)(3) of this section, (1)(1) Except Exceptasas stated in paragraph 905(b)(3) of this no (1) section, no "construction allowed on the “construction loads”(1) are loads” allowed are on the SP-Series joists SP-Series joists until all bridging is installed and until all bridging is installed and anchored, and all joist anchored, and all joist bearing seats are attached. Introduction (5) In the case of bottom chord bearing joists, the ends of the joist must be restrained laterally per Section 904.5(f) before releasing the hoisting cables. placed one foot (0.30 of m)decking of the are bearing c) The joistswithin supporting the bundle attached surface of the joist end. at both ends. g) The edge of the construction load shall be placed d) All rowsone of bridging arem) installed anchored. within foot (0.30 of the and bearing surface of (1) the joist end. e) The total weight of the decking does not exceed 4000 poundsof(1816 A copy the kilograms). OSHA Steel Erection Standard §1926.757, Open Web Steel Joists, is included at f) The edge of the bundle of decking shall be placed within www.newmil.com for reference. Construction loads are one footfor (0.30 of the bearing surface the joist defined therein joistm)purposes as “any loadofother thanend. the weight of the employee(s), the joists and the bridging.” (5) The edge of the construction load shall be placed within one A copy of the OSHA Steel Erection Standard foot (0.30 m) ofWeb the bearing the be joistfound end. at §1926.757, Open Steel surface Joists, of may (2) Standard Specification (1)www.newmil.com for reference. Qualified person is A copy of the OSHA Steel Erection Standard §1926.757, defined therein as “one who, by possession of a Open Web Steel Joists, is included at www.newmill.com recognized degree, certificate, or professional standing, or for reference. Construction loads are defined for joist who by extensive knowledge, training, andtherein experience, has successfully demonstrated abilityof the to solve or purposes as “any load other than thetheweight employee(s), resolve problems relating to the subject matter, the work, the joists and the bridging.” or the project.” Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 99 SP-Series Design Special Profile Joists Introduction STANDARD SPECIFICATION, SP-SERIES The following abbreviated design examples demonstrate the selection of an SP-Series joist from the Weight Tables given all necessary geometry and loading information. The information found in the SP-Series Weight Tables includes the uniform self-weight of the joist as well as bridging and seat-depth requirements. For Scissor (SPSC) and Arch (SPAC) Joists, the table will noteprofile if the horizontal is greater than This and The following examples serve as brief examples of going from a special geometrydeflection to the SP-Series load2”. tables allowance is for a pin-roller bearing anchorage condition. The and determining the uniform self weight of the joist, the bridging requirements, the seat depth, and for Scissor (SPSC) horizontal deflection, or slip, is at the roller end. Arch (SPAC) Joists, the table will note if the horizontal deflection is greater than 2”. This allowance is for a pin-roller 906.1 GABLE EXAMPLE anchorage condition and the horizontal deflection, or slip, is at the roller end. ALL TABLES ARE BASED ON ASD Gable Joist Example GABLE JOIST (SPGB) From the above diagram, the following information is used to enter the Gable Joists (SPGB) Weight Tables on page 19. Span: 40’-0” Depth: 46” is used to enter End 6” Top Chord Pitch: From the above diagram, theCenter following information theDepth: Gable Joists (SPGB) Tables on page 24. 2” / foot Total Load: 300 plf The weight tables are based on a 0.75 Live to Total Load ratio (300 x 0.75 = 225 plf) and check Total Load: 300 plf Uplift Load: 160 plf Total Load is the result of worst-case equivalent uniform load, WeqM-TL, based on investigation of This load is not shown in the above diagram but is called out on the contract drawings in the NET all load cases. SP-Series Tables Span: 40’-0” Center Depth: 46” End Depth: 2” / foot for a Live Load Deflection not 6” to exceed L/240,Top orChord 40’ x Pitch: 12 / 240 = 2” maximum deflection for 225 plf. UPLIFT plan and calculated for the given joist spacing. Live Load: 120 plf SP-Series tables are based on a 0.75 Live to Total Load ratio (300 x 0.75 = 225 plf) and check for a Live Load deflection not to exceed L/240, or 40’ x 12 / 240 = 2” maximum deflection for 225 plf. The Live Load in this example, 120 plf, isgeometry less than is 75found percentonofpage the total From the information above, the correct 23.load, 225 plf, therefore deflection is within limits. Joist Designation: 46 SPGB 300 / 225 / 160 From the table: Uplift Load: 160 plf JoistUplift Self-Weight: PLF Net is not shown in23the above diagram but is called out in the contract documents in the Bridging Required: 3 Rows of Bolted X-Bridging NET UPLIFT plan. Seat Depth: 5” Deep Seats Joist Designation: 46 SPGB 300 / 120 /should 160 be noted on the contract documents and reflected in the section details. Bridging and seat depth information Standard Specification From the information above, the correct geometry is found on page 28. From the table: Joist Self-Weight: Bridging Required: Seat Depth: 8 PLF 3 Rows of Bolted X-Bridging 5” Deep Seats Bridging and seat depth information should be noted in the contract documents and reflected in the section details. Discover the easiest way to specify special profile joists: 100 www.newmill.com/digital-tools 95 STANDARD SPECIFICATION, SP-SERIES Introduction 906.2 BOWSTRING EXAMPLE STANDARD SPECIFICATION – SP SERIES ALL TABLES ARE BASED ON ASD 906.2 BOWSTRING EXAMPLE EXAMPLES BASED ON ASD Special Profile Joists BOWSTRING JOIST (SPBW) From the above diagram, the following information is used to enter the Bowstring Joists (SPBW) Weight Tables on page From 35. the above diagram, the following information is used to enter the Bowstring Joists (SPBW) Tables on page 40. Center 46” End Depth: 6” End Depth: 6” Top 62’-0” Chord Radius: 62’-0” Center Depth: 46”Depth: Top Chord Radius: Total Load: 800 plf Total Load is the result of worst-case equivalent uniform load, WeqM-TL, based on investigation of Live Load: 400 plf SP-Series tables are based on a 0.75 Live to Total Load ratio (800 x 0.75 = 600 plf) and check for Uplift Load: 220 plf Net Uplift is not shown in the above diagram but is called out in the contract documents in the Total Load: 800 plf Live Load: 400 plf Uplift Load: 220 plf TotalallLoad the result of worst-case equivalent uniform load, WeqM-TL, based on investigation of load iscases. all load cases. SP-Series Design Span: 40’-0” Span: 40’-0” a Livetables Loadare Deflection to Live exceed L/240, 40’(800 x 12 / 240= 600 = 2”plf) maximum for 600 SP-Series based on not a 0.75 to Total Loador ratio x 0.75 and checkdeflection for a Live Load plf. The Live Load in this example, 400 plf,=is2”less than 75 percentforof600 theplf. total 600 in plf, therefore deflection not to exceed L/240, or 40’ x 12 / 240 maximum deflection Theload, Live Load this deflection is iswithin limits. example, 400 plf, less than 75 percent of the total load, 600 plf, therefore deflection is within limits. Net NET UpliftUPLIFT is not shown plan. in the above diagram but is called out in the contract documents in the NET UPLIFT plan. Joist Designation: 46 SPBW 800 / 400 / 220 SP-Series Tables Joist Designation: 46 SPBW 800 / 400 / 220 From the information above, the correct geometry is found on page 39. From thethe information correct geometry is found17onPLF page 44. From table: above, the Joist Self-Weight: Bridging Required: 3 Rows of Bolted X-Bridging From the table: Joist Self-Weight: 17 PLF 5” Deep Seats Seat Depth: Bridging Required: 3 Rows of Bolted X-Bridging Bridging and seat depth information noted in the contract documents and reflected in the section details. Seat Depth: should5”beDeep Seats Bridging and seat depth information should be noted in the contract documents and reflected in the section details. www.newmill.com/digital-tools 97 101 Standard Specification Discover the easiest way to specify special profile joists: Introduction STANDARD SPECIFICATION, SP-SERIES 906.3 SCISSOR EXAMPLE ALL TABLES ARE BASED ON ASD Special Profile Joists Scissor Joist Example SCISSOR JOIST (SPSC) From the above diagram, the following information is used to enter the Scissor Joists (SPSC) Weight Tables on page 51. From the above diagram, the following information is used to enter the Scissor Joists (SPSC) Tables on page 56. SP-Series Design Span: 40’-0” Chord Depth: 36” Ridge Depth: 37.1” Shape Depth: 97” Top Chord Pitch: 3 / 12 Span: 40’-0” Chord Depth: 36” Shape Depth: 97” Top Chord Pitch: 3” / foot Ridge Depth: Total Load: 600 plf The 37.1” weight tables are based on a 0.75 Live to Total Load ratio (600 x 0.75 = 450 plf) and check Total Load: 600 plf Uplift Load: 110 plf for a Live Load Deflection not to exceed L/240, or 40’ x 12 / 240 = 2” maximum deflection for 450 plf.Load is the result of worst-case equivalent uniform load, WeqM-TL, based on investigation of Total all load cases. This load is not shown in the above diagram but is called out on the contract drawings in the NET UPLIFT plan. Live Load: 370 plf SP-Series tables are based on a 0.75 Live to Total Load ratio (600 x 0.75 = 450 plf) and check for a Live Load Joist Designation: 36 deflection not to exceed L/240, or 40’ x 12 / 240 = 2” maximum deflection for 450 plf. The Live Load in this SPSC 800 / 600 / 110 example, 370 plf, is less than 75 percent of the total load, 450 plf, therefore deflection is within limits. From the information above, the correct geometry is found on page 54. SP-Series Tables Uplift Load: 110 plf From the table: Net Uplift is not shown in the above diagram but is called out in the contract documents in the Self-Weight: 18 PLF NETJoist UPLIFT plan. Bridging Required: Seat Depth: Joist Designation: 36 SPSC 600 / 370 Deflection: / 110 Horizontal 6 Rows of Bolted X-Bridging 5 Deep Seats ≤2”; as the note for x>2 is not shown in the cell Bridging and seat depth should is befound noted the60. contract documents and reflected in the section details. From the information above, information the correct geometry onon page From the table: Joist Self-Weight: Bridging Required: Seat Depth: Horizontal Deflection: 18 PLF 2 Rows of Bolted X-Bridging 5 Deep Seats ≤2”; as the note for бx>2 is not shown in the cell Standard Specification Bridging and seat depth information should be noted in the contract documents and reflected in the section details. Discover the easiest way to specify special profile joists: 102 www.newmill.com/digital-tools 97 STANDARD SPECIFICATION, SP-SERIES Introduction STANDARD SPECIFICATION – SP SERIES 906.4 ARCH EXAMPLE ALL TABLES ARE BASED ON ASD 906.4 ARCH EXAMPLE EXAMPLES BASED ON ASD Special Profile Joists ARCH JOIST (SPAC) From the above diagram, the following information is used to enter the Arch Joists (SPAC) Weight Tables on page 67. From the above diagram, the following information is used to enter the Arch Joists (SPAC) Tables on page 72. Chord Depth: 36” Total Load: Chord Depth: 36” Total Load is the result of worst-case equivalent uniform load, WeqM-TL, based on investigation of loadiscases. Total all Load the result of worst-case equivalent uniform load, WeqM-TL, based on investigation of all load cases. 315 plf Live Load: 315 plf Uplift Load: Top Chord Radius: 43’-0” Top Chord Radius: 43’-0” 450 plf Total Load: 450 plf Live Load: Shape Depth: 96” Shape Depth: 96” SP-Series tables are based on a 0.75 Live to Total Load ratio (450 x 0.75 = 338 plf) and check for a Live Load Deflection not to exceed L/240, or 40’ x 12 / 240 = 2” maximum deflection for 338 plf. SP-Series are based onexample, a 0.75 Live315 to Total ratio (45075 x 0.75 = 338ofplf) and check for a338 Liveplf, Load The tables Live Load in this plf, Load is less than percent the total load, therefore deflection not to is exceed L/240, or 40’ x 12 / 240 = 2” maximum deflection for 338 plf. The Live Load in this deflection within limits. SP-Series Design Span: 40’-0” Span: 40’-0” example, 315 plf, is less than 75 percent of the total load, 338 plf, therefore deflection is within limits. 200 plf Net Uplift is not shown in the above diagram but is called out in the contract documents in the NET UPLIFT plan. Uplift Load: 200 plf Net Uplift is not shown in the above diagram but is called out in the contract documents in the Joist Designation: NET UPLIFT plan. 36 SPAC 450 / 315 / 200 SP-Series Tables Joist Designation: 36 SPAC 450 the / 315correct / 200 geometry is found on page 71. From the information above, From table: above, the Joist Self-Weight: From thethe information correct geometry is found17 onPLF page 76. Bridging Required: 2 Rows of Bolted X-Bridging Seat Depth: 5” Deep Seats Joist Self-Weight: Deflection: 17 PLF ≤2”; as the note for >2 is not shown in the cell Horizontal x From the table: Bridging Required: 2 Rows of Bolted X-Bridging Seat Depth: should5 be Deep Seatsin the contract documents and reflected in the section details. Bridging and seat depth information noted Horizontal Deflection: ≤2”; as the note for x>2 is not shown in the cell Bridging and seat depth information should be noted in the contract documents and reflected in the section details. Standard Specification Discover the easiest way to specify special profile joists: www.newmill.com/digital-tools 99 103 Standard Specification SP-Series Tables SP-Series Design Special Profile Joists Introduction NOTES: Discover the easiest way to specify special profile joists: 104 www.newmill.com/digital-tools Building a better steel experience... New Millennium is your nationwide resource for reliable, structural steel roof-and-floor systems. Our dynamic manufacturing facilities are strategically located across North America for all your standard and special profile steel joists, plus steel roof and floor decking. Indiana Manufacturing Facility 6115 County Road 42 Butler, IN 46721 Phone: (260) 868-6000 Fax: (260) 868-6001 Nevada Manufacturing Facility 8200 Woolery Way Fallon, NV 89406 Phone: (775) 867-2130 Fax: (775) 867-2169 Virginia Manufacturing Facility 100 Diuguids Lane Post Office Box 3400 Salem, VA 24153 Phone: (540) 389-0211 Fax: (540) 389-0378 Mexico Manufacturing Facility Carr. Panamericana 9920 Col. Puente Alto C.P. 32695 Cuidad Juarez Chihuahua Mexico Phone: (915) 298-5050 Fax: (915) 298-4040 Florida Manufacturing Facility 1992 NW Bascom Norris Drive Lake City, FL 32055 Phone: (386) 466-1300 Fax: (386) 466-1301 Corporate Office 7575 W. Jefferson Blvd. Fort Wayne, IN 46804 Phone: (260) 969-3500 Arkansas Manufacturing Facility 3565 Highway 32 North Hope, AR 71801 Phone: (870) 722-4100 Fax: (870) 722-4245 © 2014 New Millennium Building Systems, LLC All rights reserved. New Millennium Building Systems is a wholly owned subsidiary of Steel Dynamics Inc.