ST 3000 Smart Transmitter
Transcription
ST 3000 Smart Transmitter
ST 3000 Smart Transmitter Release 300 with HART Communications Option User Manual Doc. No.: 34-ST-25-17 Revision Date: 6/05 Notices and Trademarks Notices and Trademarks Copyright 2005 by Honeywell Inc. June 2005 While this information is presented in good faith and believed to be accurate, Honeywell disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customers. In no event is Honeywell liable to anyone for any indirect, special or consequential damages. The information and specifications in this document are subject to change without notice. Honeywell is a U.S. registered trademarks Of Honeywell Inc. Other brand or product names are trademarks of their respective owners. Honeywell International, Inc. Industrial Measurement and Control 2500 W. Union Hills Drive Phoenix, Arizona 85027 Patent Notice This product is covered by one or more of the following U.S. Patents: 4,520,488; 4,567,466; 4,494,183; 4,502,335; 4,592,002; 4,553,104; 4,541,282; 4,806,905; 4,797,669; 4,735,090; 4,768,382; 4,787,250; 4,888,992; 5,811,690; 5,875,150; 5,765,436; 4,734,873; 6,041,659 and other patents pending. ii ST 3000 HART Transmitter Release 300 User Manual 6/05 About This Document About This Document Revision Notes The following list provides notes concerning all revisions of this document. Doc ID Date 34-ST-25-17 Notes st 9/99 1 7/00 Updated illustrations to show new terminal block (three screw terminal) and R300 electronics housing. 10/04 Updated bolt torque specs, parts lists. 2/05 Updated for CFF Flange Mount 6/05 Updated with STA info. issue of document. Contacts World Wide Web The following lists Honeywell’s World Wide Web sites that will be of interest to our industrial automation and control customers. Honeywell Organization WWW Address (URL) Corporate http://www.honeywell.com Industrial Automation and Control http://www.iac.honeywell.com International http://www.honeywell.com/Business/global.asp Telephone Contact us by telephone at the numbers listed below. Organization 6/05 Phone Number United States and Canada Honeywell Inc. Industrial Automation and Control 1-800-343-0228 1-800-525-7439 Asia Pacific Honeywell Asia Pacific Inc. Hong Kong (852) 8298298 Europe Honeywell PACE Brussels, Belgium [32-2] 728-2111 Latin America Honeywell Inc. Sunrise, Florida U.S.A. (305) 364-2355 ST 3000 HART Transmitter Release 300 User Manual Sales Service iii About This Document Technical Assistance If you encounter a problem with your ST 3000 Smart Transmitter, check to see how your transmitter is currently configured to verify that all selections are consistent with your application. If the problem persists, you can reach Honeywell’s Solution Support Center for technical support by telephone during normal business hours. An engineer will discuss your problem with you. Please have your complete model number, serial number, and software revision number on hand for reference. You can find the model and serial numbers on the transmitter nameplates. You may also seek additional help by contacting the Honeywell distributor who supplied your ST 3000 transmitter. Technical Assistance Contact Honeywell Solution Support Center By Telephone In the U. S: 1-800-423-9883 Outside the U.S: 1-602-313-6510 ace@honeywell.com By E-mail Problem Resolution If it is determined that a hardware problem exists, a replacement transmitter or part will be shipped with instructions for returning the defective unit. Please do not return your transmitter without authorization from Honeywell’s Solution Support Center or until the replacement has been received. Symbol definitions The following table lists those symbols used in this document to denote certain conditions. Symbol Definition This CAUTION symbol on the equipment refers the user to the Product Manual for additional information. This symbol appears next to required information in the manual. This WARNING symbol on the equipment refers the user to the Product Manual for additional information. This symbol appears next to required information in the manual. WARNING: risk of electrical shock. This symbol warns the user of a potential shock hazard where HAZARDOUS LIVE voltages greater than 30 Vrms, 42.4 Vpeak, or 60 VDC may be accessible. ATTENTION, Electrostatic Discharge (ESD) hazards. Observe precautions for handling electrostatic sensitive devices Protective Earth (PE) terminal. Provided for connection of the protective earth (green or green/yellow) supply system conductor. Earth Ground. Functional earth connection. NOTE: This connection shall be bonded to Protective earth at the source of supply in accordance with national and local electrical code requirements. iv ST 3000 HART Transmitter Release 300 User Manual 6/05 Contents Contents 1— Introduction - First Time Users Only .................................................................... 1 Overview..............................................................................................................................................1 ST 3000 Smart Transmitters ...............................................................................................................2 HART Communicator ..........................................................................................................................7 Transmitter Order ................................................................................................................................8 Local Smart Meter Option ...................................................................................................................9 2— Quick Start Reference ....................................................................................... 11 Overview............................................................................................................................................11 Getting ST 3000 Transmitter On-Line Quickly ..................................................................................12 3— Preinstallation Considerations ........................................................................... 13 Overview............................................................................................................................................13 CE Conformity (Europe) Notice.........................................................................................................13 Considerations for ST 3000 Transmitter ...........................................................................................14 Considerations for HART communicator...........................................................................................16 Considerations for Local Smart Meter Option ...................................................................................16 4— Installation ......................................................................................................... 17 Overview............................................................................................................................................17 Mounting ST 3000 Transmitter..........................................................................................................17 Piping ST 3000 Transmitter...............................................................................................................28 Wiring ST 3000 Transmitter ..............................................................................................................33 5— Getting Started................................................................................................... 39 Overview............................................................................................................................................39 Establishing Communications ...........................................................................................................39 Making Initial Checks.........................................................................................................................42 6— Configuration ..................................................................................................... 45 Overview............................................................................................................................................45 Configuration Overview .....................................................................................................................46 6/05 ST 3000 HART Transmitter Release 300 User Manual v Contents Tag— Entering a Tag Number ..........................................................................................................55 PV unit— Selecting Unit of Pressure Measurement .........................................................................56 Range Values— Setting PV URV and PV LRV.................................................................................57 Device Information.............................................................................................................................59 Pressure transfer function— Selecting Output Conformity ...............................................................60 PV damping— Adjusting Damping Time ...........................................................................................62 SV units— Selecting Secondary Variable units ................................................................................63 Poll addr— Selecting Poll Address....................................................................................................64 Disconnecting the Communicator .....................................................................................................64 7— Start-up.............................................................................................................. 65 Overview............................................................................................................................................65 Start-up Tasks ...................................................................................................................................66 Running Analog Output .....................................................................................................................67 Flow Measurement with DP Transmitter ...........................................................................................69 Pressure Measurement with DP Transmitter ....................................................................................71 Liquid Level Measurement – Vented Tank........................................................................................73 Liquid Level Measurement – Pressurized Tank ................................................................................75 Pressure or Liquid Level Measurement with GP Transmitter............................................................78 Pressure Measurement with AP........................................................................................................81 Liquid Level Measurement with DP Transmitter with Remote Seals ................................................83 8— Operation........................................................................................................... 87 Introduction........................................................................................................................................87 Accessing Operation Data.................................................................................................................87 Changing Default Failsafe Direction and Write Protect Jumpers ......................................................90 Writing Data in the Message Area.....................................................................................................92 Saving and Restoring a Configuration Database ..............................................................................93 9— Maintenance ...................................................................................................... 97 Introduction........................................................................................................................................97 Preventive Maintenance ....................................................................................................................97 Inspecting and Cleaning Barrier Diaphragms ...................................................................................97 Replacing Printed Wiring Assembly (PWA).....................................................................................100 Replacing Meter Body .....................................................................................................................103 10— Calibration ..................................................................................................... 107 vi ST 3000 HART Transmitter Release 300 User Manual 6/05 Contents Introduction......................................................................................................................................107 Overview..........................................................................................................................................107 Calibrating Analog Output Signal ....................................................................................................108 Calibrating Range............................................................................................................................109 Resetting Calibration .......................................................................................................................111 11— Troubleshooting ............................................................................................. 113 Introduction......................................................................................................................................113 Troubleshooting Overview...............................................................................................................113 To access transmitter diagnostics ...................................................................................................113 Diagnostic Messages ......................................................................................................................114 Interpreting Messages .....................................................................................................................116 Clearing Critical Status ....................................................................................................................118 12— Parts List........................................................................................................119 Replacement Parts ..........................................................................................................................119 13— Reference Drawings ...................................................................................... 137 Wiring Diagrams ..............................................................................................................................137 Appendix A— Smart Meter Reference ................................................................... 139 Introduction......................................................................................................................................139 Smart Meter Display ........................................................................................................................141 Smart Meter Specifications .............................................................................................................143 Setting Range Values (Local Zero and Span).................................................................................144 Configuring Smart Meter Using Pushbuttons..................................................................................147 Setting smart meter display using the HART communicator...........................................................160 Typical smart meter indications.......................................................................................................163 Operation error codes......................................................................................................................164 Meter/transmitter interaction............................................................................................................165 Appendix B— Configuration Record Sheet ............................................................ 167 ST 3000 R300 Smart Transmitter with HART Communications .........................................................................................................................................................167 Appendix C – Freeze Protection of Transmitters.................................................... 169 Possible Solutions/Methods ............................................................................................................169 6/05 ST 3000 HART Transmitter Release 300 User Manual vii Contents Appendix D —Hazardous Area Classifications ...................................................... 179 Introduction......................................................................................................................................179 North American Hazardous Location Standards.............................................................................179 International Electrotechnical Commission (IEC) Classifications....................................................184 Enclosure Ratings ...........................................................................................................................187 Index ......................................................................................................................189 viii ST 3000 HART Transmitter Release 300 User Manual 6/05 Tables Tables Table 1 ST 3000 Pressure Transmitter Family ..............................................................................................................5 Table 2 Local Smart Meter Options ............................................................................................................................10 Table 3 Start-up Tasks Reference................................................................................................................................12 Table 4 Operating Temperature Limits (Transmitters with Silicone Fill Fluid DC200) .............................................15 Table 5 Transmitter Maximum Allowable Working Pressure (MAWP) Ratings........................................................16 Table 6 Mounting ST 3000 Transmitter to a Bracket ..................................................................................................18 Table 7 Zero Corrects Procedure for Transmitters with a Small Differential Pressure Span ......................................21 Table 8 Flush Mount Transmitter Installation .............................................................................................................24 Table 9 Mounting Remote Diaphragm Seal Transmitter.............................................................................................26 Table 10 Suggested Transmitter Location for Given Processes ..................................................................................29 Table 11 Process Connections .....................................................................................................................................30 Table 12 Flange Description........................................................................................................................................31 Table 13 Installing Flange Adapter .............................................................................................................................32 Table 14 Wiring the Transmitter .................................................................................................................................35 Table 15 Starting Communications with Transmitter..................................................................................................41 Table 16 Reviewing Factory-Set Configuration Parameters .......................................................................................42 Table 17 Summary of Pressure Transmitter Configuration Parameters ......................................................................48 Table 18 Entering Tag Number ...................................................................................................................................55 Table 19 Selecting Engineering Units .........................................................................................................................56 Table 20 Keying in LRV and URV .............................................................................................................................57 Table 21 Setting LRV and URV to Applied Pressures................................................................................................58 Table 22 Viewing/Entering Device Information Data.................................................................................................59 Table 23 Selecting Output Conformity........................................................................................................................60 Table 24 Adjusting Damping Time .............................................................................................................................62 Table 25 Selecting SV Temperature Units ..................................................................................................................63 Table 26 Selecting Poll Address..................................................................................................................................64 Table 27 Start-up Procedure Reference .......................................................................................................................66 Table 28 Using Transmitter in Constant-Current Source (Output) Mode ...................................................................67 Table 29 Starting Up DP Transmitter for Flow Measurement.....................................................................................69 Table 30 Starting Up DP Transmitter for Pressure Measurement ...............................................................................71 Table 31 Starting Up DP Transmitter for Liquid Level Measurement in Vented Tank...............................................73 Table 32 Starting Up DP Transmitter for Liquid Level Measurement in Pressurized Tank........................................76 Table 33 Starting Up GP Transmitter for Pressure or Liquid Level Measurement .....................................................79 Table 34 Starting Up AP Transmitter for Pressure Measurement. ..............................................................................82 Table 35 Starting Up DP Transmitter with Remote Seals for Liquid Level Measurement .........................................83 Table 36 Summary of Keystrokes for Operation Data Access ....................................................................................88 Table 37 Changing Default Failsafe Direction or Write Protect Jumper.....................................................................91 Table 38 Writing Data in the Message Area................................................................................................................92 Table 39 Saving a Configuration Database .................................................................................................................94 Table 40 Downloading a Configuration Database.......................................................................................................95 Table 41 Inspecting and Cleaning Barrier Diaphragms.............................................................................................100 Table 42 Process Head Bolt Torque Ratings .............................................................................................................102 Table 43 Replacing PWA ..........................................................................................................................................102 Table 44 Replacing Meter Body Only.......................................................................................................................105 Table 45 Calibrating Output Signal for Transmitter in Analog Mode.......................................................................110 Table 46 Calibrating Measurement Range ................................................................................................................111 Table 47 Resetting Calibration Data..........................................................................................................................113 Table 48 Summary of Diagnostic Messages for Critical Failures .............................................................................116 Table 49 Summary of Diagnostic Messages for Non-Critical Failures .....................................................................117 Table 50 Summary of Diagnostic Messages for Communication Errors...................................................................117 Table 51 Diagnostic Message Interpretation Table ...................................................................................................118 Table 52 Resetting the Transmitter............................................................................................................................120 6/05 ST 3000 HART Transmitter Release 300 User Manual ix Tables Table 53 Major ST 3000 Smart Transmitter Parts Reference....................................................................................123 Table 54 Parts Identification for Callouts in Figure 42 and Figure 43 ......................................................................125 Table 55 Parts Identification for Callouts in Figure 44. ............................................................................................126 Table 56 Parts Identification for Callouts in Figure 45. ............................................................................................129 Table 57 Parts Identification for Callouts in Figure 46. ............................................................................................130 Table 58 Replacement GP and AP Process Head Part Numbers for Narrow Profile Meter Body ...........................131 Table 59 Parts Identification for Callouts in Figure 47. ............................................................................................132 Table 60 Parts Identification for Callouts in Figure 48. ............................................................................................133 Table 61 Parts Identification for Callouts in Figure 49. ............................................................................................134 Table 62 Parts Identification for Callouts in Figure 50. ............................................................................................136 Table 63 Parts Identification for Callouts in Figure 51. ............................................................................................137 Table 64 Summary of Recommended Spare Parts. ...................................................................................................139 Table A-1 Description of Smart Meter Display Indicators........................................................................................141 Table A-2 Smart Pushbutton Description..................................................................................................................142 Table A-3 Smart meter specifications. ......................................................................................................................143 Table A-4 Setting Range Values Using Local Zero and Span Adjustments..............................................................144 Table A-5 Smart Meter Engineering Units Code ......................................................................................................148 Table A-6 Selecting Engineering Units .....................................................................................................................149 Table A-7 Setting Lower Display Values for Smart Meter Display..........................................................................152 Table A-8 Setting Upper Display Value for Smart Meter Display............................................................................155 Table A-9 Smart meter display setup using HART communicator ...........................................................................161 Table A-10 Summary of Typical Smart Meter Indications. ......................................................................................163 Table A-11 Smart Meter Error Codes and Descriptions............................................................................................164 Table C-1 Temperature Range of Freeze Protection Systems ...................................................................................176 Table C-2 Steam Pressure Versus Steam Temperature Values .................................................................................177 Table D-1 Temperature Identification Numbers (NEC/CEC) ...................................................................................181 Table D-2 FM Entity Parameters...............................................................................................................................183 Table D-3 Temperature Identification Numbers (IEC)..............................................................................................185 Table D-4 NEMA Enclosure Type Numbers and Comparable IEC Enclosure Classification ..................................188 Table 1 Additions to the User Manual.......................................................................................................................200 Table 2 Torque Table - Process Head Bolts/Nuts.....................................................................................................201 Table 3 Parts Identification for Callouts in Figure 1 ................................................................................................202 Table 4 Process Head Assembly Kits .......................................................................................................................204 Table 5 Pressure Specification and Ratings Summary Comparisons .......................................................................205 x ST 3000 HART Transmitter Release 300 User Manual 6/05 Figures Figures Figure 1 Typical ST 3000 Differential Pressure Transmitter.........................................................................................2 Figure 2 Functional Block Diagram for Transmitter in Analog Mode of Operation. ....................................................3 Figure 3 Typical Communication Interface...................................................................................................................7 Figure 4 Typical ST 3000 Transmitter Order Components. ..........................................................................................8 Figure 5 ST 3000 with Local Smart Meter Option. .......................................................................................................9 Figure 6 Typical Mounting Area Considerations Prior to Installation.........................................................................14 Figure 7 Typical Bracket Mounted and Flange Mounted Installations........................................................................18 Figure 8 Leveling Transmitters ...................................................................................................................................21 Figure 9 Typical Flange Mounted Transmitter Installation .........................................................................................22 Figure 10 Typical Flush Mounted Transmitter Installation .........................................................................................24 Figure 11 Typical Flange and Pipe Mounted Installations ..........................................................................................25 Figure 12 Typical Remote Diaphragm Seal Transmitter Installation. .........................................................................27 Figure 13 Typical 3-Valve Manifold and Blow-Down Piping Arrangement. .............................................................28 Figure 14 Typical Piping Arrangement for ½” NPT Process Connection ...................................................................29 Figure 15 Operating Range for ST 3000 Transmitters. ...............................................................................................33 Figure 16 ST 3000 Transmitter Terminal Blocks ........................................................................................................34 Figure 17 Ground Connection for Lightning Protection..............................................................................................36 Figure 18 Typical Communicator Connections...........................................................................................................40 Figure 19 Write Protection and Failsafe Direction Jumper Location ..........................................................................43 Figure 20 Smart Meter Display with All Indicators Lit...............................................................................................44 Figure 21 Summary of Configuration Process.............................................................................................................46 Figure 22 Communicator and ST 3000 Transmitter Memories ...................................................................................47 Figure 23 Online (or HOME) Menu Summary............................................................................................................50 Figure 24 HART Communicator Menu Summary ......................................................................................................51 Figure 25 HART Communicator Keyboard ................................................................................................................52 Figure 26 Square Root Dropout Point .........................................................................................................................61 Figure 27 Typical Communicator and Meter Connections for Constant-Current Source (Output) Mode..................68 Figure 28 Typical Piping Arrangement for Flow Measurement with DP Type Transmitter .......................................69 Figure 29 Typical Piping Arrangement for Pressure Measurement with DP Type Transmitter..................................71 Figure 30 Typical Piping Arrangement for Liquid Level Measurement with DP Type Transmitter and Vented Tank73 Figure 31 Typical Piping Arrangement for Liquid Level Measurement with DP Type Transmitter and Pressurized Tank. 75 Figure 32 Typical Piping Arrangement for Pressure Measurement with GP Type Transmitter..................................78 Figure 33 Typical Piping Arrangement for Liquid Level Measurement with GP Type Transmitter...........................79 Figure 34 Typical Piping Arrangement for Pressure Measurement with AP Type Transmitter..................................81 Figure 35 Typical Piping Arrangement for Liquid Level Measurement with DP Type Transmitter with Remote Seals. 83 Figure 36 Location of Failsafe and Write Protect Jumpers on PWA...........................................................................90 Figure 37 Summary of Save and Restore Database Function......................................................................................93 Figure 38 Disassembly of DP Transmitter Process Heads from Meter Body............................................................101 Figure 39 Typical Range Calibration Hookup...........................................................................................................112 Figure 40 Major ST 3000 Smart Transmitter Parts Reference. .................................................................................122 Figure 41 Major ST 3000 Smart Transmitter Parts Reference. .................................................................................123 Figure 42 Series 100/900 Electronics Housing - Electronics/Meter End...................................................................124 Figure 43 Series 100/900 Electronics Housing - Terminal Block End ......................................................................124 Figure 44 Series 100 and Series 900 DP Meter Body for Models STD924 & STD930 C, D, G, H, K, and L and STD974..............................................................................................................................................................125 Figure 45 Series 900 DP Meter Body for Models STD924 & STD930 A, B, E, F, and J .........................................128 Figure 46 Series 100 GP and AP Meter Bodies and Series 900 AP Meter Body ......................................................130 Figure 47 Series 900 Dual-Head GP Meter Bodies. ..................................................................................................132 6/05 ST 3000 HART Transmitter Release 300 User Manual xi Figures Figure 48 Series 100 and Series 900 LGP/LAP Meter Body. ...................................................................................133 Figure 49 Series 900 Flush Mount Meter Body.........................................................................................................134 Figure 50 Series 100 and Series 900 Flange Mounted Meter Body. .........................................................................135 Figure 51 High Temperature Meter Body. ................................................................................................................137 Figure A-1 Smart Meter Display with All Indicators Lit...........................................................................................141 Figure A-2 Typical Setup for Setting Range Values Using Local Zero and Span Adjustments................................147 Figure C-1 Piping Installation for Sealing Liquid With Specific Gravity Heavier Than Process Fluid. ..................170 Figure C-2 Piping Installation for Sealing Liquid with Specific Gravity Lighter Than Process Fluid.....................170 Figure C-3 Piping Installation for Gas Flow..............................................................................................................171 Figure C-4 Piping Installation for Differential Pressure Transmitter with Metal Diaphragm Seals.........................172 Figure C-5 Piping Installation for Process Pressure Transmitter with Metal Diaphragm Seal.................................172 Figure C-6 Piping Installation for Differential Pressure Transmitter and Impulse Piping with Electric Heating and Control...............................................................................................................................................................173 Figure C-7 Piping Installation for Process Pressure Transmitter and Impulse Piping with Electric Heating Control.174 Figure C-8 Piping Installation for Differential Pressure Transmitter and Impulse Piping with Steam Heating. .......175 Figure C-9 Piping Installation for Process Pressure Transmitter and Impulse Piping with Steam Heating. .............176 Figure 1 ST 3000 Model STD110, STD120, STD125, STD130, STD170, STD924, STD930 (Rev S or greater)...............................................................................................................................................................201 xii ST 3000 HART Transmitter Release 300 User Manual 6/05 IMPORTANT IMPORTANT Before You Begin, Please Note Transmitter Terminal Blocks Depending on your transmitter options, the transmitter may be equipped with either a 3-screw or 5-screw terminal block inside the electronics housing. This may affect how to connect the loop wiring and meter wiring to the transmitter. See Table 14 in Section 4 for the terminal block connections for each type terminal. Section 13 provides additional wiring diagrams showing alternate wiring methods. + - METER + TEST L+ - + - + - SIGNAL SIGNAL - SIGNAL + Electronics Housing Terminal Block TEST Electronics Housing Terminal Block Internal Ground Terminal Internal Ground Terminal 3-Screw Terminal Block 6/05 5-Screw Terminal Block ST 3000 HART Transmitter Release 300 User Manual xiii 1— Introduction - First Time Users Only - Overview 1— Introduction - First Time Users Only Overview About this section This section is intended for users who have never worked with our ST 3000 Smart Transmitter with HART communications. It provides some general information to acquaint you with the ST 3000 transmitter and the HART communications interface. Section contents This section includes these topics: 6/05 • ST 3000 Smart Transmitters – Brief description of the ST 3000 transmitter form, functions and identification. • HART Communicator – Brief description of the communication interface used with the ST 3000 HART transmitter. • Transmitter order – Describes the components shipped with a transmitter order. • Local Smart Meter Option – Describes the smart meter options available with the transmitter. ST 3000 HART Transmitter Release 300 User Manual 1 1— Introduction - First Time Users Only - ST 3000 Smart Transmitters ST 3000 Smart Transmitters About the transmitter The ST 3000 Smart Transmitter comes in a variety of models for measurement applications involving one of these basic types of pressure: • Differential Pressure • Gauge Pressure • Absolute Pressure The transmitter measures the process pressure and transmits an output signal proportional to the measured variable over a 4 to 20 milliampere, two-wire loop. Its major components are an electronics housing and a meter body as shown in Figure 1 for a typical differential pressure model transmitter. Electronics Housing Meter Body Figure 1 Typical ST 3000 Differential Pressure Transmitter. 2 ST 3000 HART Transmitter Release 300 User Manual 6/05 1— Introduction - First Time Users Only - ST 3000 Smart Transmitters Functional block diagram Besides the process variable (PV) output, the transmitter also provides its meter body temperature as a secondary variable (SV) which is only available as a read-only parameter through the communicator interface. See Figure 2. Factory Characterization Data Electronics Housing Meter Body PROM Temperature Sensor Static Pressure Sensor Multiplexer DP or PP Sensor A/D Microprocessor D/A Digital I/O Modular Electronics Proportional 4 to 20 mA PV output. (Digital signal imposed during HART interface communications) Terminal Block Pressure Figure 2 Functional Block Diagram for Transmitter in Analog Mode of Operation. 6/05 ST 3000 HART Transmitter Release 300 User Manual 3 1— Introduction - First Time Users Only - ST 3000 Smart Transmitters Series and model number data Honeywell’s line of ST 3000 Smart Transmitters includes these two series designations: • Series 100 • Series 900 se m bl y Table II 0 0 0 0 0 Table III S B, 1 C or y Fa ct io ns pt O an ge Fl et er M Table I E 1 H As dy Bo pe Ty si c Ba Key Number S T D 1 2 0 Id en ti f ica ti o n Each series includes several models to meet various process pressure measurement and interface requirements. Each transmitter comes with a nameplate located on the top of the electronics housing that lists its given “model number”. The model number format consists of a Key Number with several Table selections as shown below. Table IV XXXX You can quickly identify what series and basic type of transmitter you have from the third and fourth digits in the key number. The letter in the third digit represents one of these basic transmitter types: A = Absolute Pressure D = Differential Pressure F = Flange Mounted G = Gauge Pressure R = Remote Seals The number in the fourth digit matches the first digit in the transmitter Series. Thus, a “1” means the transmitter is a Series 100 and a “9” is a Series 900. For a complete breakdown of the Table selections in your model number, please refer to the appropriate Specification and Model Selection Guide that is provided as a separate document. ATTENTION Be aware that previous vintages of the ST 3000 transmitter with designations of Series 100, Series 100e, Series 600, and Series 900 have been supplied at various times since the ST 3000 was introduced in 1983. While all these transmitters are functionally alike, there are differences in housing and electronics design. This manual only applies for Series 100, Release 300 and Series 900, Release 300 transmitters furnished with the HART communications option (option HC). Release 300 transmitters can be identified by the “R300” designation on the nameplate. 4 ST 3000 HART Transmitter Release 300 User Manual 6/05 1— Introduction - First Time Users Only - ST 3000 Smart Transmitters ST 3000 transmitter family Table 1 illustrates the various ST 3000 Release 300 pressure transmitters that are presently available. Table 1 ST 3000 Pressure Transmitter Family Transmitter Type Series 100 Model Series 900 Model Differential Pressure STD1xx STD9xx Differential Pressure with Flange on One Side STF1xx STF9xx Dual-Head Gauge Pressure In-Line Gauge Pressure and Absolute 6/05 Not Available STG9xx STG1xL STG9xL STA1xL STA9xL ST 3000 HART Transmitter Release 300 User Manual 5 1— Introduction - First Time Users Only - ST 3000 Smart Transmitters Transmitter Type Series 100 Model Gauge and Absolute Pressure Series 900 Model STG1xx STG9xx STA1xx STA9xx STF1xx STF9xx Flange-Mount Liquid Level Differential Pressure with Remote Diaphragm Seals Flush Mount High Temperature STR1xx STR9xx Not Available STG93P STG14T Not Available STF14T 6 ST 3000 HART Transmitter Release 300 User Manual 6/05 1— Introduction - First Time Users Only - HART Communicator HART Communicator Transmitter adjustments Except for optional local zero and span adjustments, the ST 3000 has no physical adjustments. You need a HART communicator to make any adjustments in a ST 3000 with the HART communications option. Transmitter operator interface The HART communicator (Model 275) is connected to the loop wiring of the ST 3000 transmitter for direct communication with the transmitter. The hand-held communicator “talks” with a transmitter through serial digital signals over the 4 to 20 milliampere line used to power the transmitter. A request/response format is the basis for the communication operation. The transmitter’s microprocessor receives a communication signal from the communicator, identifies the request, and sends a response message. Figure 3 shows a simplified view of the communication interface provided by the communicator. Request Power Supply and Receiver 4 to 20 mA line Response ST 3000 HART Communicator Figure 3 Typical Communication Interface Communicator Purpose The communicator allows you to adjust transmitter values, or diagnose potential problems from a remote location such as the control room. You use the communicator to: • Configure: Define and enter the transmitter’s operating parameters. • Monitor: Read the input pressure to the transmitter in engineering units and the transmitter’s output in milliamperes or percent. • Display: Retrieve and display data from the transmitter or the communicator’s memory. • Check current output: Use the transmitter to supply the output current desired for verifying analog loop operation, troubleshooting, or calibrating other components in the analog loop. • Troubleshoot: Check status of transmitter operation and display diagnostic messages to identify transmitter, communication, or operator error problems. ATTENTION Throughout this manual, procedures are given on how to use the HART communicator to configure, operate and troubleshoot the ST 3000 transmitter. Keystrokes and screen displays for the HART communicator are referenced in these procedures. However, additional information on communicator operation is found in the product manual supplied with the communicator. 6/05 ST 3000 HART Transmitter Release 300 User Manual 7 1— Introduction - First Time Users Only - Transmitter Order Transmitter Order Order components Figure 4 shows the components that would be shipped and received for a typical ST 3000 transmitter order. Ordered ST 3000 Series 100 HART differential pressure transmitter with optional mounting bracket Shipped Received ST 3000 User's Manual Mounting Bracket (Optional) Figure 4 Typical ST 3000 Transmitter Order Components. About documentation – 8 ST 3000 HART Transmitter Release 300 User’s Manual, 34-ST-25-17: One copy is shipped with every order. This document provides detailed information for installing, wiring, configuring, starting up, operating, maintaining, and servicing the ST 3000 transmitter. This is the main reference manual for the ST 3000 transmitter. ST 3000 HART Transmitter Release 300 User Manual 6/05 1— Introduction - First Time Users Only - Local Smart Meter Option Local Smart Meter Option Smart meter assembly A Local Smart Meter and/or Zero and Span Adjust option comes as a separate assembly and is integrally mounted on the transmitter’s Printed Wiring Assembly (PWA) mounting bracket within the electronics housing. The meter option assembly includes a cable and plug assembly for mating with a connector on the transmitter’s PWA. A meter end-cap that includes a window is supplied on the electronics side of the transmitter’s housing so you can view the meter display with the end-cap installed. See Figure 5. Electronics Housing Local Smart Meter Option Figure 5 ST 3000 with Local Smart Meter Option. 6/05 ST 3000 HART Transmitter Release 300 User Manual 9 1— Introduction - First Time Users Only - Local Smart Meter Option Option availability Depending upon your transmitter model, it can be equipped with one of the available integral local smart meter and/or zero and span adjust options as shown in Table 2. Table 2 Local Smart Meter Options Option Description Available with Transmitter Series 100 900 Yes Yes Yes * Yes Yes * Yes Local Smart Meter only VAR SEL. UPPER VALUE 0 % 100 UNITS SET LOWER VALUE Local Smart Meter with Zero and Span Adjustments VAR SEL. SPAN UPPER VALUE 0 % 100 UNITS SET ZERO LOWER VALUE Local Zero and Span Adjustments only SPAN ZERO * Except draft range, Model STD110. 10 ST 3000 HART Transmitter Release 300 User Manual 6/05 2— Quick Start Reference - Overview 2— Quick Start Reference Overview About this section This section provides a list of typical start-up tasks and tells you where you can find detailed information about performing the task. This section assumes that the ST 3000 transmitter has been installed and wired correctly, and is ready to be put into operation. It also assumes that you are somewhat familiar with using the HART communicator and that the transmitter has been configured correctly for your application. If the transmitter has not been installed and wired, you are not familiar with HART communicator operation, and/or you do not know if the transmitter is configured correctly, please read the other sections of this manual before starting up your transmitter. 6/05 ST 3000 HART Transmitter Release 300 User Manual 11 2— Quick Start Reference - Getting ST 3000 Transmitter On-Line Quickly Getting ST 3000 Transmitter On-Line Quickly Quick start-up tasks Table 3 lists common start-up tasks for an ST 3000 transmitter using a HART communicator and gives an appropriate section in this manual to reference for more information about how to do the task. The start-up tasks are listed in the order they are commonly completed. Table 3 Start-up Tasks Reference Task 12 Description Reference Section and Topic 1 Put analog loop into manual mode Appropriate vendor documentation for controller or recorder used as a receiver in analog loop with ST 3000 transmitter. 2 Connect HART communicator to transmitter and establish communications. 5 – Getting Started Establishing Communications 3 Check/set output form (Linear/Square Root). 6 – Configuration Pressure Transfer Function 4 Check/set damping time. 6 – Configuration PV damping 5 Check/set Lower Range Value and Upper Range Value. 6 – Configuration Range Values (See Appendix A for setting range values using local zero and span adjustments) 6 Run optional output check for analog loop 7 – Start Up Running Analog Output 7 Check zero input and set, if required. 7 – Start Up See Steps 6 and 7 in Table 29. 8 Check transmitter status 8 – Operation Accessing Operation Data 9 Setup local Smart Meter, if applicable. 10 Write data in scratch pad memory, if desired. 6 – Configuration Device Information 11 Store all changes in the transmitter's nonvolatile memory. 6 – Configuration Configuration Overview Appendix A – Smart meter reference ST 3000 HART Transmitter Release 300 User Manual 6/05 3— Preinstallation Considerations - Overview 3— Preinstallation Considerations Overview About this section This section contains information that you should take into consideration before you install a new transmitter. The topics in this section include: • CE Conformity notice and special conditions for European installations. • Environmental and operating conditions, which cover operating temperature limits and overpressure ratings for safe transmitter operation. • HART communicator interface conditions. • Operating conditions for transmitters equipped with the smart meter option. Of course, if you are replacing an existing ST 3000 transmitter you may skip this section. CE Conformity (Europe) Notice About conformity and special conditions This product is in conformity with the protection requirements of 89/336/EEC, the EMC Directive. Conformity of this product with any other “CE Mark” Directive(s) shall not be assumed. Deviation from the installation conditions specified in this manual, and the following special conditions, may invalidate this product’s conformity with the EMC Directive. • You must use shielded, twisted-pair cable such as Belden 9318 for all signal/power wiring. • You must connect the shield to ground at the power supply side of the wiring only and leave it insulated at the transmitter side. ATTENTION The emission limits of EN 50081-2 are designed to provide reasonable protection against harmful interference when this equipment is operated in an industrial environment. Operation of this equipment in a residential area may cause harmful interference. This equipment generates, uses, and can radiate radio frequency energy and may cause interference to radio and television reception when the equipment is used closer than 30 meters (98 feet) to the antenna(e). In special cases, when highly susceptible apparatus is used in close proximity, the user may have to employ additional mitigating measures to further reduce the electromagnetic emissions of this equipment. 6/05 ST 3000 HART Transmitter Release 300 User Manual 13 3— Preinstallation Considerations - Considerations for ST 3000 Transmitter Considerations for ST 3000 Transmitter Evaluate conditions The ST 3000 transmitter is designed to operate in common indoor industrial environments as well as outdoors. To assure optimum performance, evaluate these conditions at the mounting area relative to published transmitter specifications and accepted installation practices for electronic pressure transmitters. • Environmental Conditions • Vibration Sources – Ambient Temperature – Relative Humidity – Pumps – Motorized Valves – Valve Cavitation • Potential Noise Sources – Radio Frequency Interference (RFI) – Electromagnetic Interference (EMI) • Process Characteristics – Temperature – Maximum Pressure Rating Figure 6 illustrates typical mounting area considerations to make before installing a transmitter. Lightning (EMI) Ambient Temperature Relative Humidity Large Fan Motors (EMI) Transceivers (RFI) Pump (vibration) Meter Body Temperature 21003 Figure 6 Typical Mounting Area Considerations Prior to Installation Temperature limits Table 4 lists the operating temperature limits for the various types of transmitters with silicone fill fluids. See transmitter specifications for temperature limits of ST 3000 transmitters with alternative fill fluids. 14 ST 3000 HART Transmitter Release 300 User Manual 6/05 3— Preinstallation Considerations - Considerations for ST 3000 Transmitter Table 4 Operating Temperature Limits (Transmitters with Silicone Fill Fluid DC200) Transmitter Type and Model Draft Range Ambient Temperature STD110 Process Interface Temperature °C °F °C °F -40 to 70 -40 to 158 -40 to 70 -40 to 158 Differential Pressure STD125 -40 to 85 -40 to 185 -40 to 85 -40 to 185 STD120, STD130, STD170 -40 to 85 -40 to 185 -40 to 125 -40 to 257 STD904, STD924, STD930, STD974 -40 to 85 -40 to 185 -40 to 125 -40 to 257 STG140, STG170, STG180 -40 to 85 -40 to 185 -40 to 125 -40 to 257 STG14L, STG17L, STG18L -40 to 85 -40 to 185 -40 to 110 -40 to 230 STG14T -40 to 85 -40 to 185 -40 to 150 † -40 to 302 † Gauge Pressure STG93P -15 to 65 5 to 149 -15 to 95 †† 5 to 203 †† STG944, STG974 -40 to 85 -40 to 185 -40 to 125 -40 to 257 STG90L, STG94L, STG97L, STG98L -40 to 85 -40 to 185 -40 to 110 -40 to 230 Absolute Pressure STA122/12L -40 to 85 -40 to 185 STA140/14L -40 to 85 -40 to 185 See Specification Sheet STA922/92L -40 to 85 -40 to 185 STA940/94L -40 to 85 -40 to 185 -40 to 80 -40 to 176 Flange Mounted STF128, STF132, STF924, STF932 -40 to 93 -40 to 200 -40 to 175 -40 to 350 Pseudo-Flanged Head STF12F, STF13F, STF92F, STF93F -40 to 93 -40 to 200 -40 to 93 -40 to 200 STF14F -40 to 85 -40 to 185 -40 to 85 -40 to 185 Gauge Pressure Flange Mount STF14T -40 to 93 -40 to 200 -40 to 150 † -40 to 302 † -40 to 80 -40 to 176 See Specification Sheet Remote Diaphragm Seals STR12D, STR13D, STR14G, STR17G, STR14A STR93D, STR94G See Specification Sheet -40 to 85 -40 to 185 See Specification Sheet See Specification Sheet † Process temperatures above 125 °C (257 °F) require a reduction in the maximum ambient temperature as follows: Process Temperature Ambient Temperature Limit 150 °C (302 °F) 50 °C (122 °F) 140 °C (284 °F) 60 °C (140 °F) 125 °C (257 °F) 85 °C (185 °F) †† Process temperatures above 65 °C (149 °F) require a 1:1 reduction in maximum ambient temperature. Note: For transmitters with local meter option see Appendix A Note: Transmitters with other fill fluids (CTFE, Neobee, Etc.) have different Operating Temperature Limits. For more specific information, refer to the appropriate Specification and Model Selection Guide or transmitter nameplate 6/05 ST 3000 HART Transmitter Release 300 User Manual 15 3— Preinstallation Considerations - Considerations for HART communicator Pressure ratings Table 5 lists maximum working pressure for a given transmitter Upper Range Limit (URL). The maximum allowable working pressure (MAWP) is the pressure used for the approval body safety calculations Table 5 Transmitter Maximum Allowable Working Pressure (MAWP) Ratings Transmitter Type Upper Range Limit (URL) MAWP Draft Range 10 inches H2O (25 mbar) 50 psi (3.5 bar) Differential Pressure 400 inches H2O (1 bar) 3000 psi (210 bar) 100 psi (7 bar) 3000 psi (210 bar) 3000 psi (210 bar) 3000 psi (210 bar) 100 psi (7 bar) 100 psi (7 bar) 300 psi (21 bar) 300 psi (21 bar) 500 psi (35 bar) 500 psi (35 bar) 3000 psi (210 bar) 3000 psi (210 bar) 6000 psi (415 bar) 6000 psi (415 bar) 10000 psi (690 bar) 10000 psi (690 bar) 400 inches H2O (1 bar) Per selected flange and material (ANSI/ASME 150#, 300#, DN PN40) Gauge Pressure Flange Mount 100 psi (7 bar) Remote Seal Absolute Pressure 400 inches H2O (1 bar) 100 psi (7 bar) Lesser MAWP of either Remote Seal selected or transmitter pressure rating 780 mmHg Absolute (1 bar) 500 psia (35 bar) 780 mmHg Absolute (1 bar) 500 psia (35 bar) Note: Maximum Allowable Working Pressure (MAWP) may vary with materials of construction and process temperature. For more specific information, refer to the appropriate Specification and Model Selection Guide or transmitter nameplate Note: To convert bar values to kilopascals (kPa), multiply by 100. For example, 3.5 bar equals 350 kPa. Considerations for HART communicator Guidelines When using the communicator to communicate with the transmitter: • Be sure the power supply voltage does not exceed 42 Vdc (30 Vdc for intrinsically safe loops). • Be sure there is at least 250 ohms of resistance between the communicator and the power supply for proper communication. • Refer to communicator product manual for such information as operating limits. Considerations for Local Smart Meter Option If your transmitter is to be installed and operated with one of the integral smart meter options, please note the Smart meter specifications and operating conditions for the meter located in Appendix A of this manual. 16 ST 3000 HART Transmitter Release 300 User Manual 6/05 4— Installation - Overview 4— Installation Overview About this section This section provides information about installing the ST 3000 transmitter. The topics in this section include: • Mounting the ST 3000 transmitter - various mounting methods are described and can be used depending upon the transmitter type. • Piping the transmitter to the process – connecting the transmitter meter body to the process piping or tank connection. • Wiring the transmitter – connecting the loop wiring and ground conductors to the transmitter, and information is given on connecting local and remote indicating meters to the transmitter. Mounting ST 3000 Transmitter Summary You can mount all transmitter models (except flush mount models and those with integral flanges) to a 2-inch (50 millimeter) vertical or horizontal pipe using our optional angle or flat mounting bracket, or a bracket of your own. Flush mount models are mounted directly to the process pipe or tank by a 1” weld nipple. Those models with integral flanges are supported by the flange connection. Figure 7 shows typical bracket mounted and flange mounted transmitter installations for comparison. Dimensions Detailed dimension drawings for given transmitter series and types are listed in Section 13 in this manual for reference. Note that abbreviated overall dimensions are also shown in the specification sheets for the given transmitter models. The procedures following assume that the mounting dimensions have already been taken into account and the mounting area can accommodate the transmitter. 6/05 ST 3000 HART Transmitter Release 300 User Manual 17 4— Installation - Mounting ST 3000 Transmitter Angle Mounting Bracket Flat Mounting Bracket Horizontal Pipe Tank Wall Flange Connection Transmitter Flange Figure 7 Typical Bracket Mounted and Flange Mounted Installations Bracket mounting Table 6 summarizes typical steps for mounting a transmitter to a bracket. Table 6 Mounting ST 3000 Transmitter to a Bracket Step 1 Action If you are using an… Optional mounting bracket, then go to Step 2. Existing mounting bracket, then go to Step 3. 18 ST 3000 HART Transmitter Release 300 User Manual 6/05 4— Installation - Mounting ST 3000 Transmitter Step Action 2 Position bracket on 2-inch (50.8 mm) horizontal or vertical pipe, and install “U” bolt around pipe and through holes in bracket. Secure with nuts and lockwashers provided. Example - Angle mounting bracket secured to horizontal or vertical pipe. Nuts and Lockwashers Nuts and Lockwashers Mounting Bracket U-Bolt Mounting Bracket Horizontal Pipe Vertical Pipe U-Bolt 3 Align appropriate mounting holes in transmitter with holes in bracket and secure with bolts and washers provided. If transmitter is … − DP type with double-ended process heads and/or remote seals, then use alternate mounting holes in end of heads − GP or AP with single-ended head, then use mounting holes in side of meter body. − In-line GP or AP, then use smaller “U” bolt provided to attach meter body to bracket. See figure below. − Dual-head GP or AP, then use mounting holes in end of process head. Inline Models Meter Body Smaller “U” bolt Use bracket for hexagonal meter body Note: If the meter body is hexagonal, you must use the additional bracket supplied. If meter body is round, discard the bracket. 4 6/05 Loosen set screw on outside neck of transmitter one full turn. Rotate electronics housing in maximum of 180 degree increment in left or right direction from center to position you require ST 3000 HART Transmitter Release 300 User Manual 19 4— Installation - Mounting ST 3000 Transmitter Step Action and tighten set screw (13 to 15 lb-in/1.46 to 1.68 N.m). Example - Rotating electronics housing. Electronics Housing 180 degrees max. 180 degrees max. Set Screw The metric socket head wrench kit supplied includes 2.5, 3, and 4mm size wrenches. You will need the 4mm size wrench for the outside set screw. Mounting Transmitters with Small Absolute or Differential Pressure Spans To minimize positional effects on pressure measurement and calibration (zero shift), take the appropriate mounting precautions that follow for transmitters with small pressure spans. Absolute Pressure and In-line Transmitters For absolute pressure and inline transmitters you must ensure that the transmitter is vertical when mounting it. You do this by leveling the transmitter side-to-side and front-to-back. See Figure 8 for suggestions on how to level the transmitter using a spirit balance. Absolute pressure models Center Section Process Head Position spirit balance on center section of meter body only. 20 ST 3000 HART Transmitter Release 300 User Manual 6/05 4— Installation - Mounting ST 3000 Transmitter In-line models Mount transmitter vertically to assure best accuracy. Position spirit balance on pressure connection surface of AP body. Figure 8 Leveling Transmitters CAUTION The mounting position of a model STA122 or STA922 Absolute Pressure Transmitter or a model STD110 Draft Range Differential Pressure Transmitter is critical as the transmitter spans become smaller. A maximum zero shift of 2.5 mm Hg for an absolute transmitter or 1.5 in H2O for a draft range transmitter can result from a mounting position which is rotated 90 degrees from vertical. A typical zero shift of 0.12 mm Hg or 0.20 in H2O can occur for a 5 degree rotation from vertical. Differential Pressure Transmitters For a transmitter with a small differential pressure span (Model STD110, for example), you must ensure that the transmitter is vertical when mounting it. You do this by leveling the transmitter side-to-side and front-to-back. See Figure 8 for suggestions on how to level the transmitter using a spirit balance. You must also zero the transmitter by following the steps in Table 7 below. Table 7 Zero Corrects Procedure for Transmitters with a Small Differential Pressure Span Step 6/05 Action 1 Attach the transmitter to the mounting bracket but do not completely tighten the mounting bolts. 2 Connect a tube between the input connections in the high pressure (HP) and low pressure (LP) heads to eliminate the affects of any surrounding air currents. ST 3000 HART Transmitter Release 300 User Manual 21 4— Installation - Mounting ST 3000 Transmitter Step 3 Action Connect 24 Vdc power to the transmitter and connect a milliammeter in series in the loop circuit to read the transmitter’s output current. See figure for typical connections. Voltmeter Differential Pressure Type Transmitter Precision Milliammeter + 250 ohms + - Power Supply - Field Terminals - Receiver + Communicator 4 Connect a communicator and establish communications with the transmitter. Follow the steps in Table 15, if needed. 5 While reading the transmitter’s output on the milliammeter, position the transmitter so the output reading is at or near zero and then completely tighten the mounting bolts. 6 Follow the steps below to do an input zero correct function using the communicator. This corrects the transmitter for any minor error that may occur after the mounting bolts are tightened. 7 Starting from “Online” menu, choose the following menu selections: • Device setup • Diag/Service • Calibration • Zero Trim You will be prompted to remove the loop from automatic control. Press OK. You will be prompted that this procedure will affect sensor calibration. Press OK. Press OK to initiate zero input corrects. You will be prompted to return the loop to automatic control. Press OK 8 22 Remove the tube from between the input connections, the power, and the milliammeter and ST 3000 HART Transmitter Release 300 User Manual 6/05 4— Installation - Mounting ST 3000 Transmitter Step Action communicator. 9 Continue with the remaining installation tasks. Flange mounting Transmitters that are furnished with integral flange connections (models STFxxx), are bolted directly to the process flange connection. Figure 9 shows a typical installation for a transmitter with the flange on the high pressure (HP) side so the HP diaphragm is in direct contact with the process fluid. The low pressure (LP) side of the transmitter is vented to atmosphere (no connection). To mount a flange mounted transmitter model, bolt the transmitter’s flange to the flange pipe on the wall of the tank. ATTENTION On insulated tanks, remove enough insulation to accommodate the flange extension. Once the transmitter is mounted, the electronics housing can be rotated to the desired position. See Table 6, Step 4 for details. It is the End User’s responsibility to provide a flange gasket and mounting hardware that are suitable for the transmitter’s service condition. To prevent degradation of performance in Flush-Mounted Flanged Transmitters, exercise care to ensure that the internal diameter of the flange gasket does not obstruct the sensing diaphragm. To prevent degradation of performance in Extended Mount Flanged Transmitters, ensure that there is sufficient clearance in front of the sensing diaphragm body. Attention: Dotted area indicates use with closed tank with reference leg. Maximum Level Variable Head H1 Reference Leg Minimum Level HP Side mounted to tank LP Side vented to atmosphere Figure 9 Typical Flange Mounted Transmitter Installation 6/05 ST 3000 HART Transmitter Release 300 User Manual 23 4— Installation - Mounting ST 3000 Transmitter Flush mounting ST 3000 flush mount transmitters (model STG9xx) are mounted directly to the process pipe or tank using a 1 inch weld nipple. Figure 10 shows a typical installation for a transmitter with a flush mount on a pipe. Follow the steps in Table 8 to install a flush mount transmitter. Table 8 Flush Mount Transmitter Installation Step 1 Action Cut a hole for a 1” standard pipe in the tank or pipe where the transmitter is to be mounted ATTENTION On insulated tanks and pipes, remove enough insulation to accommodate the mounting sleeve. 2 Weld the 1” mounting sleeve to the wall of the tank or to the hole cut on the pipe 3 Insert the meter body of the transmitter into the mounting sleeve and secure with the locking bolt 4 Tighten the bolt to a torque of 8.1 to 13.5 N · m ( 6 to 10 ft-lb). 5 Once the transmitter is mounted, the electronics housing can be rotated to the desired position. See Table 6, Step 4 for details. 1" Pipe Mount 316 SS Weld Nipple (standard option) Figure 10 Typical Flush Mounted Transmitter Installation 24 ST 3000 HART Transmitter Release 300 User Manual 6/05 4— Installation - Mounting ST 3000 Transmitter High Temperature Transmitter Mounting You can mount the high temperature transmitter directly to the process flange connection or the process piping. Figure 11 shows typical pipe and flange mounted transmitter installations for comparison. To mount a flange mounted transmitter model, bolt the transmitter’s flange to the flange on the wall of the tank or process pipe. It is the End User’s responsibility to provide a flange gasket and mounting hardware that are suitable for the transmitter’s service condition. ATTENTION On insulated tanks, remove enough insulation to accommodate the flange extension. Once the transmitter is mounted, the electronics housing can be rotated to the desired position. See Table 6, step 4. Tank Wall Flange Connection Process Pipe Transmitter Flange 1/2" NPT Connection Figure 11 Typical Flange and Pipe Mounted Installations 6/05 ST 3000 HART Transmitter Release 300 User Manual 25 4— Installation - Mounting ST 3000 Transmitter Remote seal mounting ST 3000 transmitters furnished with remote diaphragm seals (models STRxxx) can be mounted using the optional mounting brackets. (See procedure in Table 6 in this section for bracket mounting.) Follow the guidelines below to determine the mounting position of the remote seals for the given fill fluid and then use the procedure in Table 9 to mount the remote seals to the process connections. Figure 12 shows a typical installation for a remote diaphragm seal transmitter for reference. WARNING Mount the remote seal flanges within the limits stated below for the given fill-fluid in the capillary tubes. IF the fill fluid is… THEN mount the flange… Silicone DC 200 Oil no greater than 22 feet (6.7 meters) below the transmitter. Silicone DC 704 Oil no greater than 19 feet (5.8 meters) below the transmitter. Chlorotrifluorethylene (CTFE) no greater than 11 feet (3.4 meters) below the transmitter. NOTE: The combination of tank vacuum and high pressure capillary head effect should not exceed 9 psi (300 mm Hg) absolute. Table 9 Mounting Remote Diaphragm Seal Transmitter Step Action 1 Mount transmitter at a remote distance determined by length of capillary tubing. 2 To measure variable head H1, mount remote seals on tank walls as follows: • If Transmitter Model Number is… STR93D or STR12D, then connect remote seal on high pressure (HP) side of transmitter to either the lower flange or the upper flange. • If Transmitter Model Number is… STR13D, the remote seal on low pressure (LP) side of transmitter must be connected to lower flange. See Figure 12. ATTENTION On insulated tanks, remove enough insulation to accommodate the flange extension. 3 26 It is the End User’s responsibility to provide a flange gasket and mounting hardware that are suitable for the transmitter’s service condition ST 3000 HART Transmitter Release 300 User Manual 6/05 4— Installation - Mounting ST 3000 Transmitter LP Side - Model STR93D - Model STR12D HP Side - Model STR13D Maximum Level H2 Fixed Ref. Leg Variable Head H1 Minimum Level HP Side - Model STR93D - Model STR12D LP Side - Model STR13D Figure 12 Typical Remote Diaphragm Seal Transmitter Installation. 6/05 ST 3000 HART Transmitter Release 300 User Manual 27 4— Installation - Piping ST 3000 Transmitter Piping ST 3000 Transmitter Piping Arrangements The actual piping arrangement will vary depending upon the process measurement requirements and the transmitter model. Except for flush, flanged and remote diaphragm seal connections, process connections are made to ¼ inch or ½ inch NPT female connections in the process head of the transmitter’s meter body. For example, a differential pressure transmitter comes with double-ended process heads with ¼ inch NPT connections but they can be modified to accept ½ inch NPT through optional flange adapters. Some gauge pressure transmitters may have a ½ inch NPT connection that mounts directly to a process pipe. The most common type of pipe used is ½ inch schedule 80 steel pipe. Many piping arrangements use a three-valve manifold to connect the process piping to the transmitter. A manifold makes it easy to install and remove or rezero a transmitter without interrupting the process. It also accommodates the installation of blow-down valves to clear debris from pressure lines to the transmitter. Figure 13 shows a diagram of a typical piping arrangement using a three-valve manifold and blow-down lines for a differential pressure transmitter being used to measure flow. To Downstream Tap Blow-Down Valve To Upstream Tap Blow-Down Valve 3-Valve Manifold Blow-Down Piping Blow-Down Piping To Low Pressure Side of Transmitter To High Pressure Side of Transmitter To Waste To Waste 21010 Figure 13 Typical 3-Valve Manifold and Blow-Down Piping Arrangement. Another piping arrangement uses a block-off valve and a tee connector in the process piping to the transmitter as shown in Figure 14. 28 ST 3000 HART Transmitter Release 300 User Manual 6/05 4— Installation - Piping ST 3000 Transmitter Tank Wall 1/2" NPT Connection Block-off Valve Figure 14 Typical Piping Arrangement for ½” NPT Process Connection Transmitter location Table 10 lists the mounting location for the transmitter depending on the process. Table 10 Suggested Transmitter Location for Given Processes Process Liquids Suggested Location 1. Below but close to the Explanation 1. This minimizes the static head effect of the condensate. 2. This requires a siphon to protect the transmitter from process steam. The siphon retains water as a “fill fluid.” elevation of the process connection. 2. Level with or above the process connection. Gases Above the gas line The condensate drains away from the transmitter ATTENTION • For liquid or steam, the piping should slope a minimum of 25.4 mm (1 inch) per 305 mm (1 foot). Slope the piping down towards the transmitter if the transmitter is below the process connection so the bubbles may rise back into the piping through the liquid. If the transmitter is located above the process connection, the piping should rise vertically above the transmitter; then slope down towards the flowline with a vent valve at the high point. • For gas measurement, use a condensate leg and drain at the low point (freeze protection may be required here). See Appendix C for some suggested freeze protection solutions. ATTENTION Care must be taken when installing transmitters on hot processes. The operating temperature limits for the device (as outlined in Table 3) must not be exceeded. Impulse piping may be used to reduce the temperature of the process that comes into contact with the transmitter meter body. As a general rule there is a 56 degree C drop (100 degree F) in the temperature of the process for every foot of 1/2" uninsulated piping. 6/05 ST 3000 HART Transmitter Release 300 User Manual 29 4— Installation - Piping ST 3000 Transmitter Process connections Table 11 describes typical process connections for a given type of transmitter. Table 11 Process Connections Transmitter Type Differential Pressure Process Connection • Process heads with 1/4-inch NPT female connection. • Flange adapters and manifolds with 1/2-inch female connection are optional. • Models with pseudo flange on one side include 2- or 3-inch ANSI class 150 flange. Gauge Pressure • Process head with 1/2-inch NPT female connection (Series 100). • In-line 1/2-inch NPT female connection (STGxxL). • In-line ½-inch NPT male • 9/16 Aminco • DIN19213 • Process heads with 1/4-inch NPT female connection (STG9x4). • Flange adapters and manifolds with 1/2-inch female connections are optional (STG9x4). • 2-inch Sanitary Tri-Clamp (STGxxT). • Flush mount in 1” weld sleeve, with O-ring and locking bolt (STGxxP). Absolute Pressure Process head with 1/2-inch NPT female connection. (STAx22, x40, STAx2L, STA4xL) • In-line ½-inch NPT male • 9/16 Aminco • DIN19213 Flange Mounted Liquid Level Small flange 1/2-inch, 1-, 1 ½ - and 2-inch (STFxxT) 2, 3- or 4-inch flange with flush or 2-, 4- or 6-inch extended diaphragm (See Table 12) on high pressure side.* • DN 50, 80, or 100 PN 40 flange with flush or 2, 4 or 6 inch extended diaphragm (See Table 12) on High Pressure Side*. Remote Diaphragm Seals See model selection guide for description of available flanged, threaded, chemical tee, saddle, and sanitary process connections. * Reference side has standard differential pressure process head. 30 ST 3000 HART Transmitter Release 300 User Manual 6/05 4— Installation - Piping ST 3000 Transmitter Flange descriptions Table 12 describes the available flange connections for flange mounted liquid level transmitters. Table 12 Flange Description Diaphragm Type Flush or Extended Diaphragm Description 2-inch 150# serrated–face flange with 4 holes 19 mm (3/4 in) diameter on 120.7 mm (4.75 in) diameter bolt circle and an outside diameter of 150 mm (5.91 in). 2-inch 150# serrated–face flange with 8 holes 19 mm (3/4 in) diameter on 127 mm (5.00 in) diameter bolt circle and an outside diameter of 165 mm (6.50 in). 3-inch 150# serrated–face flange with 4 holes 19 mm (3/4 in) diameter on 152.4 mm (6.00 in) diameter bolt circle and an outside diameter of 190 mm (7.48 in). 3-inch 300# serrated–face flange with 8 holes 22.2 mm (7/8 in) diameter on 168.3 mm (6.62 in) diameter bolt circle and an outside diameter of 210 mm (8.27 in). 4-inch 150# serrated–face flange with 4 holes 19 mm (3/4 in) diameter on 190.5 mm (7.50 in) diameter bolt circle and an outside diameter of 230 mm (9.05 in). 4-inch 300# serrated–face flange with 8 holes 22.2 mm (7/8 in) diameter on 255 mm (10.04 in) diameter bolt circle and an outside diameter of 200 mm (7.87 in). DN 50 PN 40 serrated–face flange with 4 holes 18 mm (0.71 in) diameter on 125 mm (4.92 in) diameter bolt circle and an outside diameter of 165 mm (6.50 in). DN 80 PN 40 serrated–face flange with 8 holes 18 mm (0.71 in) diameter on 160 mm (6.30 in) diameter bolt circle and an outside diameter of 200 mm (7.87 in). DN 100 PN 40 serrated–face flange with 8 holes 22 mm (0.87 in) diameter on 190 mm (7.48 in) diameter bolt circle and an outside diameter of 235 mm (9.25 in). Pseudo Flange Head 2-inch, 150 lbs serrated-face flange with 4 holes 15.9 mm (5/8 in) diameter on 120.6 mm (4-3/4 in) diameter bolt circle and an outside diameter of 152.4 mm (6 in). 3-inch, 150 lbs serrated-face flange with 4 holes 19 mm (3/4 in) diameter on 152 mm (6 in) diameter bolt circle and an outside diameter of 190 mm (7-1/2 in). Flush Mount Gauge STG93P 25.4 mm (1-inch) pipe mount. (316L SS standard option.) General piping guidelines 6/05 • When measuring fluids containing suspended solids, install permanent valves at regular intervals to blow-down piping. • Blow-down all lines on new installations with compressed air or steam and flush them with process fluids (where possible) before connecting these lines to the transmitter’s meter body. • Be sure all the valves in the blow-down lines are closed tight after the initial blow-down procedure and each maintenance procedure after that. ST 3000 HART Transmitter Release 300 User Manual 31 4— Installation - Piping ST 3000 Transmitter Installing flange adapter Table 13 gives the steps for an optional flange adapter on the process head. ATTENTION Slightly deforming the gasket supplied with the adapter before you insert it into the adapter may aid in retaining the gasket in the groove while you align the adapter to the process head. To deform the gasket, submerse it in hot water for a few minutes then firmly press it into its recessed mounting groove in the adapter. Table 13 Installing Flange Adapter Step Action 1 Insert filter screen (if supplied) into inlet cavity of process head. 2 Carefully seat Teflon (white) gasket into adapter groove. 3 Thread adapter onto 1/2-inch process pipe and align mounting holes in adapter with holes in end of process head as required. 4 Secure adapter to process head by hand tightening 7/16-20 hex-head bolts. Example - Installing adapter on process head. Process Head Filter Screen Teflon Gasket Flange Adapter 7/16 x 20 Bolts 21011 ATTENTION Apply an anti-seize compound on the stainless steel bolts prior to threading them into the process head. 5 32 Evenly torque flange adapter bolts to a torque of 27,1 Nm +/- 1,4 Nm (20 ft lbs +/- 1.0 ft lbs) ST 3000 HART Transmitter Release 300 User Manual 6/05 4— Installation - Wiring ST 3000 Transmitter Wiring ST 3000 Transmitter Summary The transmitter is designed to operate in a two-wire power/current loop with loop resistance and power supply voltage within the operating range shown in Figure 15. When option LP (lightning protection) and/or remote smart meter are selected, the voltage drop for these options must be added to the basic transmitter voltage of 10.8 V to determine VXMTR and RLOOP MAX. Additional consideration is required when selecting intrinsic safety barriers to insure that the barriers will supply VXMTR MIN including the required 250 ohms (typically within the barriers) for digital communications. Transmitter Parameters: RLOOP MAX = The maximum loop resistance (barriers plus wiring) that will allow proper transmitter operation. Therefore, RLOOP MAX = (VSUPPLY MIN – VXMTR MIN) ÷ 21.8 mA Where, VXMTR MIN = 10.8 V + VLP + VSM VLP = 1.1 V, lightning protection option, LP VSM = 2.3 V, remote smart meter (Please note that VSM should only be considered if a remote smart meter will be connected to the transmitter.) 1440 1200 Loop Resistance (ohms) = Operating Area NOTE: A minimum of 250 0hms of loop resistance is necessary to support communications. Loop resistance equals barrier resistance plus wire resistance plus receiver resistance. Also 45 volt operation is permitted if not an intrinsically safe installation. 800 650 450 250 0 10.8 16.28 20.63 25 28.3 37.0 42.4 Operating Voltage (Vdc) 21012 Figure 15 Operating Range for ST 3000 Transmitters. The positive and negative loop wires are connected to the positive (+) and negative (–) SIGNAL terminals on the terminal block in the transmitter’s electronics housing as shown in Figure 16. 6/05 ST 3000 HART Transmitter Release 300 User Manual 33 4— Installation - Wiring ST 3000 Transmitter 5-Screw Terminal Block Lightning Protection Option (option LP) SIGNAL - SIGNAL + Electronics Housing Terminal Block + - METER + TEST L+ - + - + - SIGNAL Electronics Housing Terminal Block TEST 3-Screw Terminal Block Internal Ground Terminal Internal Ground Terminal Figure 16 ST 3000 Transmitter Terminal Blocks Each transmitter includes an internal ground terminal to connect the transmitter to earth ground. A ground terminal can be optionally added to the outside of the electronics housing. While it is not necessary to ground the transmitter for proper operation, we suggest that you do so to minimize the possible effects of “noise” on the output signal and provide additional protection against lightning and static discharge damage. Note that grounding may be required to meet optional approval body certification. Refer to Section 3, CE Conformity (Europe) Notice for special conditions. Optional lightning protection (option LP) can be ordered for transmitters that will be installed in areas highly susceptible to lightning strikes. Figure 17 shows the 5-screw terminal block used when the lightning protection option is ordered. Barriers can be installed per manufacturer’s instructions for transmitters to be used in intrinsically safe applications. Wiring connections The procedure in Table 14 shows the steps for connecting loop power to the transmitter. For loop wiring and external wiring diagrams, refer to the installation drawings presented in Section 13. Detailed drawings are provided for transmitter installation in non-intrinsically safe areas and for intrinsically safe loops in hazardous area locations. ATTENTION All wiring must comply with local codes, regulations, and ordinances. If you will be using the transmitter in a hazardous area, be sure to review the hazardous location reference data included in Appendix D of this manual before wiring and operating the transmitter. 34 ST 3000 HART Transmitter Release 300 User Manual 6/05 4— Installation - Wiring ST 3000 Transmitter Table 14 Wiring the Transmitter Step Action 1 Loosen end-cap lock using a 1.5 mm allen wrench and remove end-cap cover from terminal block end of electronics housing. 2 Feed loop power leads through one of conduit entrances on either side of electronics housing. Plug whichever entrance you do not use. The transmitter accepts up to 16 AWG wire. Loop Power 4 + - METER + - + - L -+ - + - + - TEST Loop Power SIGNAL 5-screw terminal (option LP) - SIGNAL + 3-screw terminal block SIGNAL Observing polarity, connect positive loop power lead to SIGNAL + terminal and negative loop power lead to SIGNAL – terminal. See figures. + TEST 3 Replace end-cap, and tighten end-cap lock. Approval body requirements If your transmitter was ordered with Table III option 3N for self-declared approval per 94/9/EC (ATEX4), you must use a power supply that includes a voltage limiting device that will keep the voltage to the transmitter from exceeding 42 Vdc. You can achieve this by using a battery as the supply or one of these voltage limiting means. • Double wound mains transformer per BS 3535 or equivalent. • An adequately rated zener diode whose voltage is not significantly higher than the rated voltage. • An adequately rated semiconductor voltage regulator. 6/05 ST 3000 HART Transmitter Release 300 User Manual 35 4— Installation - Wiring ST 3000 Transmitter Lightning protection When your transmitter is equipped with optional lightning protection (option LP), you must connect a wire from the transmitter to ground as shown in Figure 17 to make the protection effective. We recommend that you use a size 8 AWG (American Wire Gage) or (8.37mm2) bare or green covered wire. Electronics Housing Connect to Earth Ground Figure 17 Ground Connection for Lightning Protection. Conduit seal Transmitters installed as explosionproof in a Class I, Division 1, Group A Hazardous (Classified) Location in accordance with ANSI/NFPA 70, the US National Electrical Code (NEC), require a “LISTED” explosionproof seal to be installed in the conduit, within 18 inches of the transmitter. Crouse-Hinds® type EYS/EYD or EYSX/EYDX are examples of “LISTED” explosionproof seals that meets this requirement. Transmitters installed as explosionproof in a Class I, Division 1, Group B, C or D Hazardous (Classified) Locations do not require an explosionproof seal to be installed in the conduit. ATTENTION Installation should conform to all national and local electrical code requirements. WARNING When installed as explosionproof in a Division 1 Hazardous Location, keep covers tight while the transmitter is energized. Disconnect power to the transmitter in the non-hazardous area prior to removing end caps for service. When installed as nonincendive equipment in a Division 2 Hazardous Location, disconnect power to the transmitter in the non-hazardous area, or determine that the location is non-hazardous prior to disconnecting or connecting the transmitter wires. 36 ST 3000 HART Transmitter Release 300 User Manual 6/05 4— Installation - Wiring ST 3000 Transmitter Output meter options The ST 3000 transmitter can be equipped with any of these three optional output indicating meters that provide a 0 to 100% indication of the transmitter’s output. Meter type Wiring Connections to Transmitter Integral Smart Meter with local zero and span adjustments Integral smart meter connections — The new integral smart meter (8-wires) is connected directly to the transmitter’s PWA and is mounted to the electronics module assembly inside the electronics housing. The meter display is viewed through a window in the transmitter’s end cap. VAR SEL. UPPER VALUE SPAN 00 ZERO - % 100 UNITS SET LOWER VALUE The new integral smart meter is designed for the ST 3000 Release 300 transmitter and provides functionality not available with other smart meter designs. See Appendix A for other options of this meter and detailed information about smart meter set up and operation. Meter Output indication – • 17-segment bargraph and LCD digital readout. • Meter provides indication of transmitter’s PV output in percent of span or in actual engineering units. The meter also can display custom units. • Transmitter status also is displayed. ATTENTION Only one smart meter should be installed integrally to the transmitter. Meter type Wiring Connections to Transmitter Analog meter 10 8 6 80 10 0 0 20 40 % 60 10 2 4 Analog meter connections — You can connect the analog meter (2-wires) integrally to Release 300 transmitter’s terminal block inside the electronics housing. However, there are alternate wiring methods for connecting an analog meter remotely with the loop wiring. Section 13 in this manual illustrates alternate wiring methods for connecting an analog meter to Release 300 transmitters. Meter Output indication – • Traditional pointer and scale. 6/05 ST 3000 HART Transmitter Release 300 User Manual 37 4— Installation - Wiring ST 3000 Transmitter The third output meter option is a meter display that can be mounted remotely in a separate housing. Meter type SM 3000 smart meter connections — The smart meter (3-wires) can be connected remotely to a Release 300 transmitter. Section 13 in this manual illustrates alternate wiring methods for connecting this smart meter to Release 300 transmitters. SM 3000 Smart meter 0 Wiring Connections to Transmitter % 100 Meter Output indication – • 17-segment bargraph and digital readout to show PV out in % of span. ATTENTION Be aware that the SM 3000 remote meter only shows PV output in % of span and does not display transmitter output in custom or flow units like the new smart meter. Therefore, if you use an SM 3000 remote meter in conjunction with a new smart meter that is configured to display readings in custom or flow units, the indications of the two meters will be displayed in different units. 38 ST 3000 HART Transmitter Release 300 User Manual 6/05 5— Getting Started - Overview 5— Getting Started Overview About this section This section tells you how to establish communications with the ST 3000 and make initial checks of the transmitter’s settings and configuration using a HART hand-held communicator. This section includes these topics: • Verifying that the HART communicator contains the proper software version for communicating the ST 3000 transmitter. • Making proper connections of the HART communicator to the ST 3000 transmitter. • Begin communications between the transmitter and the communicator. • Make initial checks to the transmitter, such as checking factory set configuration, verify write protect option and failsafe direction, and change if necessary. Establishing Communications Software compatibility You need to make sure your HART communicator contains software that is compatible with the ST 3000 HART transmitter. To check software revision contained in the communicator: 1. Turn on the communicator and access the “Offline” menu. 2. Press “4” to select the Utility menu. 3. Press “5” to select Simulation mode. 4. The Manufacturer menu appears. Select “Honeywell”. 5. Select Model “ST3000”. 6. View the software revisions available for the selected model. The software versions that are compatible with the ST 3000 HART Release 300 Smart Transmitter are: Dev v2 (Device version 2) DD v1 (Device Description version 1) Upgrading HART communicator software The memory module in the HART communicator is programmed with device descriptions for specific HART-compatible devices. These device descriptions allow the communicator to recognize and “talk to” the compatible devices. If you find that your communicator does not contain the necessary application software and device descriptions, contact your Honeywell sales representative about upgrading your communicator. See also the product manual that was supplied with your communicator for further information. 6/05 ST 3000 HART Transmitter Release 300 User Manual 39 5— Getting Started - Establishing Communications Connecting the communicator You connect the hand-held communicator directly to signal terminals on the transmitter’s terminal block or at any convenient location in the 4 to 20 milliampere loop wiring. (Polarity of the communicator connection does not matter.) WARNING When the transmitter’s end-cap is removed, the housing is not explosionproof. Figure 18 shows typical communicator connections across loop wiring to a ST 3000 transmitter. ST 3000 + - SIGNAL + Power Supply - + Receiver 250 ohm + TEST - Field Terminals Note: Polarity of the Communicator connection does not matter. Communicator Figure 18 Typical Communicator Connections 40 ST 3000 HART Transmitter Release 300 User Manual 6/05 5— Getting Started - Establishing Communications Starting communications Once you connect the communicator to the transmitter, you are ready to start communicating with the transmitter. The procedure in Table 15 outlines the steps for starting communications with an ST 3000 transmitter without an assigned tag number. Table 15 Starting Communications with Transmitter Step Action 1 Turn on communicator. The communicator runs a self-test check then determines if it is connected to a transmitter. 2 If you receive a communication error message (No Device Found), check the following: • Loop resistance: Is there a minimum of 250 ohms resistance between the communicator and the power supply? • Power supply: Is power applied? Is there greater than 11 volts at the transmitter? Are you within the operating area shown in Figure 15? Correct any problems, then try communicating again. If the message, or any other error message, appears again, refer to Section 11 – Troubleshooting for probable cause. 3 If the transmitter is reporting any status messages, which will be displayed at this time, refer to Section 11 – Troubleshooting for more information. When the “Online” display—similar to the one below—appears, you have established communications with the transmitter. ST3000: PT 3011 Online 1 2 3 4 5 Device setup PV PV AO PV LRV PV URV –0.00745 inH2O 11.989 mA –12.5 inH2O 12.5 inH2O Note: Some values for PV, PV LRV and PV URV may not be displayed in the Online display, (due to the limitations of the communicator display). To view these values you must use the down arrow key to select the value and then press the right arrow key to display the value in detail. ATTENTION The flashing heart icon in the upper right corner indicates the communicator and transmitter are “talking.” 6/05 ST 3000 HART Transmitter Release 300 User Manual 41 5— Getting Started - Making Initial Checks Making Initial Checks Checking configuration data Before doing anything else, it is a good idea to review the transmitter’s factory-set configuration parameters. Table 16 outlines the steps. Table 16 Reviewing Factory-Set Configuration Parameters Step Action 1 From the “Online” menu, enter “Device setup” by pressing the right arrow (⇒) key on the communicator keypad. 2 Press the down arrow (⇓) key to scroll down to menu-item “5 Review”. When highlighted press the right arrow (⇒) key to enter review function. A display similar to the one shown below appears. ST3000:PT 3011 Review Manufacturer Honeywell HELP 3 PREV NEXT EXIT Press PREV and/or NEXT to scroll through and view the configuration data, including: • Manufacturer* • PROM ID* • Transmitter model* • Tag name • Transmitter Measurement type* • Date • PV unit • Descriptor • Maximum and minimum range limits • Message - PV URL - PV LRL* • Write protection** • PV Damping • Final assembly number • PV output in % of range • Device ID* • PV transfer function (Output conformity) • Universal revision* • PV upper range value (URV) and lower • Field device revision* range value (LRV) • Software revision* • PV AO (analog output) in milliamperes • Polling address • PV AO alarm option (failsafe direction)** • Number of request preambles* • SV (Secondary Variable) unit * This information is fixed and cannot be changed by reconfiguring the transmitter. ** Alarm option and transmitter security are jumper-selectable on the electronics board. 4 42 After reviewing the transmitter data, press EXIT which takes you back to the “Device setup” display. ST 3000 HART Transmitter Release 300 User Manual 6/05 5— Getting Started - Making Initial Checks Transmitter write protection option The ST 3000 transmitters have a transmitter security option, also known as a “write protect option,” which is jumper-selectable. You can position the jumper, located on the transmitter’s printed wiring assembly (PWA), to allow read and write access or read only access to the transmitter’s configuration database. When the jumper is in the read only position, you can only read/view the transmitter’s configuration and calibration data. The factory-default jumper position is for read and write access. There is no need to check jumper position unless you want to change it. If you do want to change the jumper position, refer to the procedure in Section 8. Figure 19 below shows the location of the write protect jumper on the PWA. Write Protect Jumper W Printed Wiring Assembly R Read and Write Read Only W 1 Failsafe Direction Jumper Figure 19 Write Protection and Failsafe Direction Jumper Location Failure mode (Failsafe) alarm jumper ST 3000 transmitters are shipped with a default failsafe direction of upscale. This means that the transmitter’s output will be driven upscale (maximum output) when the transmitter detects a critical status. You can change the direction from upscale to downscale (minimum output) by cutting jumper W1 on the transmitter’s PWA. If you do want to change the jumper position, refer to the procedure in Section 8. Figure 19 shows the location of failure mode alarm jumper on the PWA. 6/05 ST 3000 HART Transmitter Release 300 User Manual 43 - Making Initial Checks Local smart meter display indications If your ST 3000 transmitter is equipped with the smart meter option, you can check the status of all the indicators on the local smart meter LCD display by cycling power to the transmitter. The meter runs a brief self-test whenever power is applied to the transmitter. All the display indicators are lit during the self-test as shown in Figure 20. (Note that the display may revert to dashes (– – –) after the self-test until the transmitter initializes all its functions.) VAR SEL. SP AN ZERO UPPE R VALUE 0 % -18. 8 . 8 0 OUTPUT MODE CHECK STATUS KNOWN VALUE ANALOG K 100 % FLOW In H 2 O GPH mmHg GPM PSI A UNITS SET LOWER VALUE Figure 20 Smart Meter Display with All Indicators Lit. Please refer to Table A-2 in Appendix A for a description of the pushbuttons on the meter face. Appendix A in this manual contains procedures for setting up the meter display, as well as descriptions of the meter indicators, with examples of typical display indications and error codes. Use the communicator to check the transmitter’s status. 44 ST 3000 HART Transmitter Release 300 User Manual 6/05 6— Configuration - Overview 6— Configuration Overview About this section This section introduces you to ST 3000 transmitter configuration. It identifies the parameters that make up the transmitter’s configuration database and provides procedures for entering values/selections for the given configuration parameters. This section also provides an overview of the HART communicator, including data on menus and keyboard, descriptions of display selections and symbols, and information on making changes using the communicator. Section contents This section includes these topics. 6/05 • An overview of the configuration process and how messages are exchanged between transmitter and communicator. • A summary of the ST 3000 configuration parameters and how to access this data using the communicator. • An overview of the communicator keyboard, displays and menu structure. • Procedures for configuring the ST 3000 transmitter with the communicator. ST 3000 HART Transmitter Release 300 User Manual 45 6— Configuration - Configuration Overview Configuration Overview About configuration Each ST 3000 transmitter includes a configuration database that defines its particular operating characteristics. You can use a communicator to change selected parameters within a given transmitter’s database to alter its operating characteristics. This process of viewing and/or changing database parameters is called “configuration.” Figure 21 shows a graphic summary of the configuration process. Configuration Database Transmitter's Operating Characteristics View and/or change database parameters HART Communicator ST 3000 Figure 21 Summary of Configuration Process Transmitter configuration can be accomplished both on-line— with the transmitter powered up and connected to the communicator, or off-line— where you enter the configuration in the communicator and then store it in memory for later downloading to the transmitter Communicator and ST 3000 transmitter memories As shown in Figure 22, both the communicator and the ST 3000 transmitter have working memories. They serve as temporary storage areas for data exchanged between them during communications. The transmitter also has a nonvolatile memory that is the permanent storage area for a backup copy of all the data held in the working memory. Nonvolatile memory retains its data even if the transmitter loses power. The communicator has a second temporary storage area called the off-line memory (memory module or data pack). It serves as a permanent storage area for a saved configuration database. The memory module or data pack supports the communicator’s SEND function to restore a saved configuration database to a transmitter. Figure 22 shows the working relationship between communicator and transmitter memories during communications. 46 ST 3000 HART Transmitter Release 300 User Manual 6/05 6— Configuration - Configuration Overview Working Memory Working Memory Nonvolatile Memory Memory Module or Data Pack (Nonvolatile) HART Communicator ST 3000 Figure 22 Communicator and ST 3000 Transmitter Memories Copying transmitter configuration into nonvolatile memory When setting up or configuring a ST 3000, whether you are changing one value or a configuration database, all configuration data must be copied into the transmitter’s non-volatile memory to ensure the security of the data. Normally, thirty seconds after a value is changed, the transmitter automatically copies it from the transmitter’s working memory into nonvolatile memory. But, if you change a value and power is interrupted to the transmitter before the change is copied to nonvolatile memory, you will lose the data in the working memory and it will not be saved in nonvolatile memory. Therefore, when data is sent (downloaded) to the transmitter, be sure power to the transmitter is not interrupted before it can be copied to nonvolatile memory. 6/05 ST 3000 HART Transmitter Release 300 User Manual 47 6— Configuration - Configuration Overview What to configure Table 17 summarizes the parameters that are included in the configuration database for a ST 3000 pressure transmitter. Table 17 Summary of Pressure Transmitter Configuration Parameters Configuration Data Setting or Selection Tag (Transmitter Tag Number) Key in a tag identification up to eight characters in length. PV unit (Unit of Measurement) Select any one of the pre-programmed engineering units. ST 3000 transmitters with inches of water ranges are factory calibrated using pressure referenced to a temperature of 39.2°F (4°C). Pressure readings can be displayed in any one of these preprogrammed engineering units: inH2O inHg ftH2O mmH2O mmHg psi bar mbar g/Sq cm kg/Sq cm Pa kPa torr atm MPa inH2O @ 4degC mmH2O @ 4degC inH2O @ 60degF Range Values PV LRV (Lower Range Value) Key in desired value through communicator keyboard or set LRV to applied pressure. Process input for 4 mA (0%) output PV URV (Upper Range Value) Key in desired value through communicator keyboard or set URV to applied pressure. Process input for 20 mA (100%) output Local meter Setup parameters for integral smart meter display. Installed Units Upper Lower (Read only – detects if meter is installed in transmitter) (Engineering units for meter display) (Upper display limit, if applicable) (Lower display limit, if applicable) Table continued on next page ⇒ 48 ST 3000 HART Transmitter Release 300 User Manual 6/05 6— Configuration - Configuration Overview Configuration Data Setting or Selection Select or key in the following device-specific information for: Device Information Manufacturer * Model * Measurement Type * PROM ID * Tag Date Descriptor Message Write protect ** Final assembly number Device ID * Revision numbers * Universal revision * Field device revision * Software revision * * This information is fixed and is read-only. ** Write protect is jumper–selectable on the transmitter PWA. See Section 8. PV transfer function (Output Conformity) Select either: PV Damping (Damping Time Constant) Select one of these values (in seconds): SV unit (Secondary Variable) Select one of the temperature units for display of the secondary variable or meter body temperature. 0.00 0.16 Deg C Poll Address 0.32 0.48 Linear Square Root 1.00 2.00 deg F 4.00 8.00 16.0 32.0 deg R K Select the device address for the transmitter. Select address 0 for a transmitter operating in analog mode, as well as support for HART communications. (Factory set address) Select address 1 to 15 for a transmitter operating in multidrop mode. Interface menus Information available through the communicator is accessed through menus. The procedures in this manual give the shortest path from the “Online” (or HOME) menu. There are alternate paths which, depending on your starting point, may be better suited. 6/05 ST 3000 HART Transmitter Release 300 User Manual 49 6— Configuration - Configuration Overview Online menu The online menu is displayed when the communicator is connected to a powered transmitter or the loop wiring and is switched on. Figure 23 summarizes the menus available from the “Online” menu. A number in parenthesis (p. 44) refers you to an appropriate page in this manual containing information about that selection/function. To HART Communicator menu ONLINE Device setup PV (p. 84) PV AO (p. 84) PV LRV (p. 54) PV URV (p. 54) Process variables Pressure AO Pressure % range (p. 84) SV (p. 85) Diagnostics/Service Master reset Calibration Device status (p. 109) Loop test (p. 63) D/A trim (p. 104) Basic setup Tag (p. 52) PV Unit(p. 53) Range values (p. 54, 55) Local Meter (Appendix A) Device information (p. 56) PV transfer function (p. 57) PV Damping (p. 59) SV units (p. 60) Detailed setup Sensors Signal condition Output condition Device information Same as shown in Basic setup HOME Menu Zero trim (p. 66, 76) Correct input LRV (p. 105) Apply values (p. 55,68,70,72,73,76,80,82) Correct input URV (p. 105) Enter values Reset corrects (p. 107) Critical (p. 110) Non-Critical (p. 110) PV LRV PV LRL PV URV PV URL Installed Units Manufacturer Model Measurement type PROM ID Tag (p. 52) Analog output HART output AO out Loop test (p. 63) AO Alarm type D/A trim (p. 104) Scaled D/A trim (p. 86) Date Descriptor Message (p. 56,88) Write protect PV Damping (p. 59) PV URV (p. 54) PV LRV (p. 54) Transfer function (p. 57) PV % range (p. 84) Upper Lower Final assembly number Device id Revision numbers Universal rev Field device rev Software rev PV PV unit (p. 53) Sensor information SV (p. 85) Temperature unit LRL URL Poll address Num request preambles Review (P. 40) Manufacturer Model Measurement type PV Unit PV URL PV LRL PV Damping PV % range PV Xfer function PV URV PV LRV PV AO PV AO Alarm type SV Unit PROM ID Tag Date Descriptor Message Write protect Final assembly number Device id Universal rev Field device rev Software rev Poll address Number of request preambles Figure 23 Online (or HOME) Menu Summary 50 ST 3000 HART Transmitter Release 300 User Manual 6/05 6— Configuration - Configuration Overview Hart Communicator menu Figure 24 summarizes the menus available from the “HART Communicator” menu. The “HART Communicator” menu is accessed by backing out (pressing the left arrow on the keypad) from the “Online” menu. HART Communicator Offline Online Frequency device Utility Offline New configuration Saved Configuration Module, Data pack or PC contents Edit Copy to . . . Send Print Delete Rename Compare Takes you to HOME menu See Figure 23. Manufacturer Model Field device rev. From blank template Mark all Unmark all Edit individually Specifies storage location (memory) where you want the configuration to be stored. The configuration name can be changed, if desired. Send (download) a saved configuration to connected device. Frequency device Frequency Pressure Utility Configure Communicator System Information Listen for PC Storage Location Simulation Selects and compares a device configuration with another device configuration. PV unit PV Damping PV URV PV LRV Transfer function Temperature unit Tag Message Save as . . . Communicator setup and operation settings. Please refer to the communicator product manual or use the online help for details on these menu options. Polling Contrast Off Time Ignore diagnostics Delete Configuration Figure 24 HART Communicator Menu Summary 6/05 ST 3000 HART Transmitter Release 300 User Manual 51 6— Configuration - Configuration Overview Interface keyboard Figure 25 shows the elements of the HART Communicator keyboard. Display screen F1 F2 F3 F4 HART Communicator I On/Off key >>> O Function keys Pressing these keys issues command of highlighted text that appears on display screen directly above them. Hot key Arrow keys A B C D 7 J Alphanumeric keypad K T L M % U V ■ N W & < ■ ■ H I 9 O P Q R 6 X Y 2 0 ■ G 5 1 # F 8 4 S E Z / 3 ■ > * _ : + ■ ■ ■ ■ ■ . Move cursor in direction indicated (up, down, right, left). Correspond to arrows on display screen. Arrow keys used to indicate position of characters that appear at top of buttons in keypad 22899 Figure 25 HART Communicator Keyboard 52 ST 3000 HART Transmitter Release 300 User Manual 6/05 6— Configuration - Configuration Overview Interface characteristics Keep in mind the following display-selection descriptions when configuring a transmitter. These selections are highlighted at the bottom of the display screen, directly above the four function keys at the top of the communicator’s keypad (F1, F2, F3, and F4). To make desired highlighted selection, press the corresponding function key. Function Key HOME Description or Action Takes you back to the “Online” display. EXIT Backs you out of the current display. END Backs you out of one level to the next higher level. ABORT Cancels a procedure backing you out of current display, and allows you to make another choice. ESC Cancels a procedure backing you out of current display, and allows you to make another choice. SEND Downloads the contents of the communicator’s working memory to the transmitter’s memory. Changes made in the communicator’s working memory are not transferred to the transmitter until a SEND command is issued. If you have not sent the changes and are about to turn off the communicator, you will receive a prompt warning you that there is unsent data and asking if you want to send it before shutting off. NEXT and PREV ENTER HELP DEL Allows you to scroll through a list of configured parameters. Allows you to choose the highlighted selection or to continue after performing an action, such as removing the loop from automatic control. Gives a brief definition/explanation of the current selection or display. Deletes character directly beneath flashing cursor. Symbols Symbol Description or Action ♥ Flashing heart icon in the upper right corner of display screen indicates that the transmitter and communicator are “talking.” When this symbol appears on the display screen it indicates that you can press the left arrow on the keypad to back out to another display. ⇑ and/or ⇓ ⇒ [>>>] These arrows appear on the display screen to indicate there is more information to scroll through, using the indicated arrow on the keypad. This arrow appears on the display screen to indicate that a menu item contains more information that can be accessed by pressing the right arrow on the keypad. This “hot” key on the keypad allows you to access range values (LRV, URV, LRL, and URL) directly. When finished, you return to the spot from which you started. ATTENTION An alternate way of selecting a menu item, besides using the up and down arrows, is to press the key corresponding to the number left of the desired menu item. 6/05 ST 3000 HART Transmitter Release 300 User Manual 53 6— Configuration - Configuration Overview Making changes When a selection in a list is highlighted (see “PV Damping” display below): Using (⇑ ) and (⇓) arrow keys, scroll through choices until desired selection is highlighted, then press ENTER ([F4] function key). ATTENTION An alternate way of selecting a menu choice is to press the key corresponding to the number left of the desired menu item. (For example: Pressing “3” would select 0.32 seconds in the PV Damping display below.) When current selection is displayed with the same information repeated and highlighted directly beneath it (see “URV” display below): Using keypad, key in a new value, then press ENTER ([F4] function key). ST3000: PT 3011 Pres URV 12.5 inH2O 12.5 HELP ESC DEL ENTER When keying in alphanumeric characters: To key in an alpha character or any symbol that appears at the top of a key, first press the arrow key (at bottom of keypad) indicating the position of that character on the key, then press key. See the example below to key in the word DATE. + =D + =A + =T + =E To key in a numeric character, merely press the key. 54 ST 3000 HART Transmitter Release 300 User Manual 6/05 6— Configuration - Tag— Entering a Tag Number Tag— Entering a Tag Number ATTENTION If you want to record the configuration data for your transmitter, there is a Configuration Record Sheet provided in Appendix B. The procedure in Table 18 shows how to enter a sample tag number of PT 3011 into the transmitter’s configuration database. Table 18 Entering Tag Number Step Action 1 From the “Online” menu, select “Device setup” (with “Device setup” highlighted, press the right arrow key (⇒) on keypad). 2 At “Device setup” menu, scroll down to “Basic setup.” Press right arrow key (⇒). 3 With “Tag” highlighted, press right arrow key (⇒). 4 When “Tag” display appears, key in tag name (for example: PT 3011) which can be a maximum of eight characters. Refer to “Making changes” in the previous section for information on keying in alphanumeric characters. 5 Press ENTER. 6 Either: • press SEND to download change to transmitter, or • go to another procedure and continue making changes. 6/05 ST 3000 HART Transmitter Release 300 User Manual 55 6— Configuration - PV unit— Selecting Unit of Pressure Measurement PV unit— Selecting Unit of Pressure Measurement You can choose to have the pressure measurements displayed in one of the pre-programmed engineering units in the communicator. The procedure in Table 19 shows how to select the desired pre-programmed engineering units. Table 19 Selecting Engineering Units Step Action 1 From “Online” menu, select “Device setup” and press right arrow key. 2 Scroll down to “Basic setup” and press right arrow key. 3 Scroll down to “PV Unit” and press right arrow key. 4 At “Pressure unit” display, use the [⇑] and [⇓] keys to scroll through available units listed below. 5 InH2O psi Pa inH2O @4degC InHg bar kPa mmH2O @4degC ftH2O mbar torr inH2O @60degF mmH2O g/Sqcm atm mmHg kg/Sqcm MPa When the desired unit is highlighted, press ENTER. Pressing ESC will cancel procedure without changing unit selection. 6 Either: • press SEND to download change to transmitter, or • go to another procedure and continue making changes. ATTENTION Since the engineering units affect the value of LRV and URV, it is recommended that you send the changed PV unit to the transmitter and then verify and change as required the values of LRV and URV. 56 ST 3000 HART Transmitter Release 300 User Manual 6/05 6— Configuration - Range Values— Setting PV URV and PV LRV Range Values— Setting PV URV and PV LRV You can set the LRV and URV by either keying in the desired values through the communicator keypad or applying the corresponding LRV and URV pressures directly to the transmitter. Procedure for keying in LRV and URV Table 20 gives the procedure for keying in the range values for a sample 5 to 45 inH2O range. (If inH2O is not the unit being used, follow the procedure in Table 19 to change it.) ATTENTION • ST 3000 Smart Transmitters are factory calibrated with inches of water ranges using inches of water pressure referenced to a temperature of 39.2˚F (4˚C). • For a reverse range, enter the upper range value as the LRV and the lower range value as the URV. For example, to make a 0 to 50 psi range a reverse range, enter 50 as the LRV and 0 as the URV. • When setting the range using applied pressures (procedure in Table 21), the URV changes automatically to compensate for any changes in the LRV and to maintain the present span (URV – LRV). When entering the LRV with the keypad (in Table 20), the URV does not change automatically. • If you are using the applied pressure method and must change both the LRV and URV, always change the LRV first. Table 20 Keying in LRV and URV Step 1 Action Starting at the “Online” menu, press the right arrow key to step through the following menu selections: • Device setup • Basic setup • Range values • PV LRV 2 Key in the desired LRV setting (for example: 5). Press ENTER. This takes you back to “Range values” menu. 3 Choose “PV URV” and press right arrow key. 4 Key in the desired URV setting (for example: 45). Press ENTER. 5 Either: • press SEND to download change to transmitter, or • go to another procedure and continue making changes. 6/05 ST 3000 HART Transmitter Release 300 User Manual 57 6— Configuration - Range Values— Setting PV URV and PV LRV Procedure for setting range values to applied pressure Table 21 gives the procedure for setting range values to sample applied pressures. ATTENTION • When setting the range using applied pressures (procedure in Table 21), the URV changes automatically to compensate for any changes in the LRV and to maintain the present span (URV – LRV). When entering the LRV with the keypad (in Table 20), the URV does not change automatically. • If you are using the applied pressure method and must change both the LRV and URV, always change the LRV first. Table 21 Setting LRV and URV to Applied Pressures Step 1 Action Starting at the “Online” menu, press the right arrow key to step through the following menu selections: • Device setup • Diag/Service • Calibration • Apply values You will be warned to remove the loop from automatic control. After doing so, press OK to continue. 2 When the following display appears ST3000: PT 3011 Set the: 1 2 3 4mA 20mA Exit ABORT ENTER choose 4mA, then press ENTER. A display will prompt you to apply new 4 mA input. 3 Apply known input pressure to transmitter that represents LRV for 4 mA (0%) output. Press OK. 4 When the “Current applied process value:” display appears, choose “Set as 4mA value” then press ENTER. This returns you to display shown in Step 2. 5 Repeat Steps 2 through 4 to set the URV to the applied input pressure for 20 mA output. 6 Select Exit and press ENTER. You will be prompted to return the loop to automatic control. After doing so, press OK. ATTENTION You can also use the local zero and span adjustments on the new smart meter to set the lower and upper range values to applied pressures. See Appendix A for the procedure. 58 ST 3000 HART Transmitter Release 300 User Manual 6/05 6— Configuration - Device Information Device Information Device information menu contains important data for device identification, such as transmitter type, device tag, serial numbers and revision numbers of the transmitter. Some data is fixed and is read only for identification purposes. Table 22 outlines the steps for accessing data under the device information menu. Table 22 Viewing/Entering Device Information Data Step Action 1 From “Online” menu, select “Device setup” and press right arrow key. 2 Scroll down to “Basic setup” and press right arrow key. 3 Scroll down to “Device Information” and press right arrow key. 4 At “Device Information” display, use the [⇑] and [⇓] keys to scroll through available parameter selections listed below. Parameter Value Manufacturer * Honeywell Model * ST3000 Measurement type * Pressure sensor type (DP, GP, AP) PROM ID * 10-digit PROM ID number Tag PT3011 (or enter an 8 character tag name if one is not shown) Date Enter date Descriptor Up to 8 character description Message Key in a message (up to 32 characters), if desired. Write protect ** No (or Yes) Final assembly number Up to an 8 digit number Device ID * First 7 characters of PROM ID Revision numbers * Universal rev 2 Field device rev 1 Software rev 1 * This data is fixed and cannot be changed by reconfiguring the transmitter. ** Write protection is selected by changing a jumper on the transmitter PWA. See Section 8. 5 When the desired parameter is highlighted, press right arrow key. Note: If the parameter value is highlighted with a blinking cursor, the value can be changed. Enter a new value, if desired and press ENTER. Note: Pressing ESC will cancel action without changing selection. 6 Either: • press SEND to download change to transmitter, or • go to another procedure and continue making changes. 6/05 ST 3000 HART Transmitter Release 300 User Manual 59 6— Configuration - Pressure transfer function— Selecting Output Conformity Pressure transfer function— Selecting Output Conformity Output form options You can select the transmitter’s output to represent either a straight linear calculation, or a square root calculation for flow measurement applications using a differential pressure type transmitter. Thus, we refer to the linear or the square root selection as the output conformity or the output form. The procedure in Table 23 shows how to select the desired Output conformity. Table 23 Selecting Output Conformity Step Action 1 From “Online” menu, select “Device setup” and press right arrow key. 2 Scroll down to “Basic setup” and press the right arrow key. 3 Scroll down to “PV xfer fnctn” and press the right arrow key. 4 Using the [⇑] and [⇓] keys, choose either Linear or Square root, then press ENTER. 5 Either: • press SEND to download change to transmitter, or • go to another procedure and continue making changes. About square root output For differential pressure transmitters measuring the pressure drop across a primary element, the flow rate is directly proportional to the square root of the differential or pressure drop. The ST 3000 transmitter’s output is automatically converted to equal percent of flow when its output conformity is configured as square root. You can use these formulas to manually calculate the percent of flow for comparison purposes. (Note: This formula assumes that LRV = 0.) ∆P Span • 100 = %P Where, Therefore, ∆P = Differential pressure input in engineering units Span = Transmitter’s measurement span (URV – LRV) %P = Pressure input in percent of span %P 100 • 100 = % Flow And, you can use this formula to determine the corresponding current output in milliamperes direct current. (% Flow • 16 mA) + 4 mA = mA dc Output 60 ST 3000 HART Transmitter Release 300 User Manual 6/05 6— Configuration - Pressure transfer function— Selecting Output Conformity EXAMPLE: If you have a differential pressure transmitter with a range of 0 to 100 inches of water with an input of 49 inches of water, substituting into the previous formulas yields: 49 100 • 100 = 49% 49% 100 • 100 = 70% Flow, and 70% • 16 + 4 = 15.2 mA dc Output Square root dropout To avoid unstable output at readings near zero, the ST 3000 transmitter automatically drops square root conformity and changes to linear conformity for low differential pressure readings. As shown in Figure 26, the point is near 0.5% of input for ST 3000 transmitters. 0utput (mA dc) 6.4 Flow (% of Span) 15 14 13 12 Dropout Points 11 5.6 10 9 re ua Sq 8 o Ro u tC rve 7 6 4.8 5 4 3 2 1 4 0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 Differential Pressure (% Full Scale) Figure 26 Square Root Dropout Point 6/05 ST 3000 HART Transmitter Release 300 User Manual 61 6— Configuration - PV damping— Adjusting Damping Time PV damping— Adjusting Damping Time You can adjust the damping time to reduce the output noise. We suggest that you set the damping to the smallest value that the system can accept. ATTENTION The electrical noise effect on the output signal is partially related to the turndown ratio of the transmitter. As the turndown ratio increases, the peak-to-peak noise on the output signal increases. You can use this formula to find the turndown ratio using the range information for your transmitter. Upper Range Limit Turndown Ratio = (Upper Range Value – Lower Range Value) EXAMPLE: The turndown ratio for a 400 inH2O transmitter with a range of 0 to 50 inH2O would be: 400 8 Turndown Ratio = (50 – 0) = 1 or 8:1 The procedure in Table 24 outlines how to adjust the damping time. Table 24 Adjusting Damping Time Step Action 1 From “Online” menu, select “Device setup” and press right arrow key. 2 Scroll down to “Basic setup” and press right arrow key. 3 Scroll down to “PV Damp” and press right arrow key. 4 At “PV Damping” display, use the [⇑] and [⇓] keys to scroll through selections until desired value is highlighted. Press ENTER. The damping values are set at: 0.00 s, 2.00 s, 0.16 s, 0.32 s, 4.00 s, 8.00 s, 0.48 s, 1.00 s, 16.0 s, 32.0 seconds. If you do not want to change the damping value, press ABORT. 5 Either: • press SEND to download change to transmitter, or • go to another procedure and continue making changes. 62 ST 3000 HART Transmitter Release 300 User Manual 6/05 6— Configuration - SV units— Selecting Secondary Variable units SV units— Selecting Secondary Variable units You can select the temperature units for display of the secondary variable, which is the meter body temperature. Table 25 Selecting SV Temperature Units Step Action 1 From “Online” menu, select “Device setup” and press right arrow key. 2 Scroll down to “Basic setup” and press right arrow key. 3 Scroll down to “SV Unit” and press right arrow key. 4 Use the [⇑] and [⇓] keys to scroll down to highlight the desired temperature units: degC 5 degF degR Kelvin When the desired selection is highlighted, press ENTER. Pressing ESC will cancel procedure without changing unit selection. 6 Either: • press SEND to download change to transmitter, or • go to another procedure and continue making changes. 6/05 ST 3000 HART Transmitter Release 300 User Manual 63 6— Configuration - Poll addr— Selecting Poll Address Poll addr— Selecting Poll Address You can select the poll address for the transmitter that determines certain communications characteristics. HART communications protocol provides for communications to multiple HART devices connected on the same loop (multidrop mode). In a multidrop mode, each device in the loop must be given a unique address. A device with a poll address of 1 through 15 is identified as being in multidrop mode. Communication between the communicator and the devices takes place digitally, with the analog output remaining constant (fixed at 4 mA average). A device with a poll address of 0 (zero) will provide a 4 to 20 mA analog output as well as receive requests and respond to commands from the HART communicator. The steps in Table 26 show how set the poll address of the transmitter. ST 3000 transmitters are shipped from the factory with poll address 0. Table 26 Selecting Poll Address Step Action 1 From “Online” menu, select “Device setup” and press right arrow key. 2 Scroll down to “Detailed setup” and press right arrow key. 3 Scroll down to “Output condition” and press right arrow key. Select “HART output” and press right arrow key. Press the right arrow key to change “Poll addr” for transmitter. • Key in address 0 for a transmitter operating in analog mode, as well as support HART communications. • Key in address from 1 to 15 for a transmitter operating an a multidrop mode. 5 Press ENTER. Pressing ESC will cancel procedure without changing unit selection. 6 Either: • press SEND to download change to transmitter, or • go to another procedure and continue making changes. Disconnecting the Communicator Disconnection checklist Do the following steps before disconnecting the communicator: • Make sure the transmitter is not in the current output mode. • Download all configuration database changes to the transmitter’s memory by selecting SEND. 64 ST 3000 HART Transmitter Release 300 User Manual 6/05 7— Start-up - Overview 7— Start-up Overview About this section This section identifies typical start-up tasks associated with several generic pressure measurement applications. It also includes the procedure for running an optional analog output check. This section includes these topics. Performing an analog output check Start up procedures for the different types of pressure transmitters in various applications, such as DP transmitter in a flow measurement DP transmitter in a pressure measurement DP transmitter in a liquid level measurement applications GP transmitter in pressure or liquid level measurement applications AP transmitter in a pressure measurement DP transmitter with remote diaphragm seals in a liquid level measurement application ATTENTION All procedures in this manual assume a transmitter poll address of 0 (zero). See Section 6, for information about poll address. 6/05 ST 3000 HART Transmitter Release 300 User Manual 65 7— Start-up - Start-up Tasks Start-up Tasks About start-up Once you have installed and configured a transmitter, you are ready to start up the process loop. Start-up usually includes • Applying process pressure to the transmitter, • Checking zero input, and • Reading input and output. You can also run an optional output check to “wring out” an analog loop prior to start-up. Procedure reference The actual steps in a start-up procedure will vary based on the type of transmitter and the measurement application. In general, you use the communicator to check the transmitter’s input and output under static process conditions, and make adjustments as required, before putting the transmitter into full operation with the running process. Choose the applicable procedure to reference in this section from Table 27 based on your type of transmitter and the measurement application. The reference procedure will give you some idea of the typical tasks associated with starting up a transmitter in a given application. Table 27 Start-up Procedure Reference IF transmitter type is ... Differential Pressure (DP) 66 AND application is ... THEN reference procedure in ... Flow Measurement Table 29 Pressure Measurement Table 30 Liquid Level Measurement for Vented Tank with Dry Reference Leg* Table 31 Liquid Level Measurement for Pressurized Tank with Liquid-Filled Reference Leg* Table 32 Gauge Pressure (GP) Pressure or Liquid Level Measurement** Table 33 Absolute Pressure (AP) Pressure Measurement** Table 34 DP with Remote Seals Liquid Level Measurement Table 35 * These applications also apply for flange-mounted liquid level type transmitters that are usually mounted directly to a flange at the zero level of the tank. ** These applications also apply for GP and AP type transmitters equipped with remote seals. However, you can only confirm that input pressure correlates with transmitter output in processes using remote seal connections. ST 3000 HART Transmitter Release 300 User Manual 6/05 7— Start-up - Running Analog Output Running Analog Output Background You can put the transmitter into a constant-current source mode to check out other instruments in the loop such as recorders, controllers, and positioners. Using the communicator, you can tell the transmitter to change its output to any value between 4 mA (1V or 0%) and 20 mA (5V or 100%) and maintain that output. This makes it easy to verify loop operation through the accurate simulation of transmitter output signals before bringing the loop on line. Note that the constant-current source mode is also referred to as the output mode. ATTENTION The transmitter does not measure the input or update the output while it is in the constantcurrent source mode. Procedure The procedure in Table 28 outlines the steps for using a transmitter in the constant current source mode. Table 28 Using Transmitter in Constant-Current Source (Output) Mode Step 1 Action Connect communicator across loop wiring and turn it on. If possible, locate communicator where you can also view receiver instrument in control loop. If you want to verify loop calibration, connect a precision milliammeter or voltmeter in loop to compare readings. Refer to Figure 27 for sample communicator and meter connections in a typical analog loop with a differential pressure-type transmitter. 2 From the “Online” menu, step through the following menu selections by highlighting and pressing the right arrow key: • Device setup • Dig/Service • Loop test You will be prompted to remove the loop from automatic control. After doing so, press OK. 3 At the “Choose analog output level” display, select 4mA to set the output signal level to 4 mA (1.0V or 0%). Press ENTER. The communicator notifies you that the transmitter’s output is fixed at 4 mA. 4 Check that receiving device indication is at its 0% point. If applicable, check that milliammeter reading is 4 mA or voltmeter reading is 1.0V. If indication is inaccurate, check the calibration of receiving device. Use the transmitter output as a calibration input source for instruments in the loop. • If you want to choose a 20 mA output value, then press OK and go to Step 5. • If you want to choose another output value, then press OK and go to Step 7. • If you have completed the loop test, then press OK and go to Step 8. 5 Select 20mA to set output signal to 20 mA (5.0V or 100%). Press ENTER. The communicator notifies you that the transmitter ‘s output is fixed at 20 mA. 6/05 ST 3000 HART Transmitter Release 300 User Manual 67 7— Start-up - Running Analog Output Step 6 Action Check that receiving device indication is at its 100% point. If applicable, check that milliammeter reading is 20 mA or voltmeter reading is 5.0V. • If you want to choose another output value, then press OK and go to Step 7. • If you have completed the loop test, then press OK and go to Step 8. 7 Select Other and press ENTER, then use communicator’s keyboard to enter other values. For example, Transmitter output If you want an output of: 8.0 mA 8.8 mA 12.0 mA 16.0 mA 2.0V 2.2V 3.0V 4.0V PV in % 25% 30% 50% 75% Communicator keystrokes press 8 and ENTER. press 8.8 and ENTER. press 12 and ENTER. press 16 and ENTER. The communicator notifies you that the transmitter’s output is fixed at that value. When you have completed the loop test, press OK and go to Step 8. 8 Select “End” and press ENTER. The communicator will notify you that it is returning the transmitter to its original output. A screen will prompt you to return the loop to automatic control. After doing so, press OK. Voltmeter Precision Milliammeter Field Terminals Red + + + Power Supply - - LP Black - HP 250 Ω Receiver + HART hand-held Commnicator Differential Pressure Transmitter Note: Polarity of the Communicator connection does not matter. Figure 27 Typical Communicator and Meter Connections for Constant-Current Source (Output) Mode 68 ST 3000 HART Transmitter Release 300 User Manual 6/05 7— Start-up - Flow Measurement with DP Transmitter Flow Measurement with DP Transmitter Procedure The procedure in Table 29 outlines the steps for starting up a differential pressure (DP) type transmitter in a liquid flow measurement application. Refer to Figure 28 for the piping arrangement identification and Figure 27 for typical communicator and meter connections. LP Blockoff LP HP Plug G Plug F HP Blockoff Valve B Valve A Valve C Differential Pressure Transmitter Figure 28 Typical Piping Arrangement for Flow Measurement with DP Type Transmitter ATTENTION For the procedure in Table 29, we are assuming that all the valves on the three-valve manifold and the block-off valves were closed at installation. Table 29 Starting Up DP Transmitter for Flow Measurement Step Action 1 Connect communicator across loop wiring; turn it on and establish communications. If possible, locate communicator where you can also view receiver instrument in control loop. If you want to verify transmitter output, connect a precision milliammeter or voltmeter in loop to compare readings. Refer to Figure 27 for sample communicator and meter connections in a typical analog loop with a differential pressure-type transmitter. 6/05 ST 3000 HART Transmitter Release 300 User Manual 69 7— Start-up - Flow Measurement with DP Transmitter Step 2 Action Open equalizer valve C. Refer to Figure 28 for sample piping arrangement. 3 Open valves A and HP block-off to make differential pressure zero (0) by applying same pressure to both sides of meter body. Allow system to stabilize at full static pressure—zero differential. 4 At the “Online” menu, read the applied input pressure (PV). Also check that the PV analog output displays a corresponding zero input pressure. 5 Check that milliammeter reading is 4 mA (0%) output. If communicator and milliammeter readings are… • exactly 4 mA, then go to Step 9. • not exactly 4 mA, then go to Step 6. 6 From “Online” menu, step through the following menu selections: • Device setup • Diag/Service • Calibration • Zero trim 7 Under “Zero trim” do the following when prompted: • Remove the loop from automatic control, then press OK. • Press OK when warned that this will affect sensor calibration. • Press OK when “Apply 0 input to sensor.” display appears. You will receive a message telling you that the sensor input is stabilizing, then the sensor zero succeeded. • Return the loop to automatic control, then press OK. 8 Press HOME to return to “Online” menu. Repeat Steps 4 and 5. 9 Close equalizer valve C. 10 Open valve B and LP block-off valve to begin measuring process differential pressure. 11 Take communicator and milliammeter readings to check that output signal does correspond to applied input pressure. If readings do not correspond, check that transmitter has been installed correctly. If applicable, blow down piping to be sure no foreign matter is entrapped in it. Check communicator and milliammeter readings again. If readings are still not correct, verify transmitter’s configuration data and change its range setting, if necessary. 12 70 Remove communicator and milliammeter from loop. ST 3000 HART Transmitter Release 300 User Manual 6/05 7— Start-up - Pressure Measurement with DP Transmitter Pressure Measurement with DP Transmitter Procedure The procedure in Table 30 outlines the steps for starting up a differential pressure (DP) type transmitter in a pressure measurement application. Refer to Figure 29 for the piping arrangement identification and Figure 27 for typical communicator and meter connections. Valve D Plug C Valve A H Differential Pressure Transmitter HP side HP Vent LP side LP Vent Figure 29 Typical Piping Arrangement for Pressure Measurement with DP Type Transmitter Table 30 Starting Up DP Transmitter for Pressure Measurement Step Action 1 Connect communicator across loop wiring; turn it on and establish communications. If possible, locate communicator where you can also view receiver instrument in control loop. If you want to verify transmitter output, connect a precision milliammeter or voltmeter in loop to compare readings. Refer to Figure 27 for sample communicator and meter connections in a typical analog loop with a differential pressure-type transmitter. 2 Close valve D. Refer to Figure 29 for sample piping arrangement. 3 Open plug C and valve A to apply head pressure H to meter body. Then, open LP vent. Allow system to stabilize at head pressure 4 6/05 At “Online” menu, read present LRV setting. ST 3000 HART Transmitter Release 300 User Manual 71 7— Start-up - Pressure Measurement with DP Transmitter Step 5 Action From “Online” menu, step through the following menu selections: • Device setup • Diag/Service • Calibration • Apply values You will be warned to remove the loop from automatic control. After doing so, press OK to continue 6 When the following display appears, ST3000: PT 3011 Set the: 1 2 3 4mA 20mA Exit ABORT ENTER choose 4mA, then press ENTER. A display will prompt you to apply new 4 mA input. Press OK. 7 When “Current applied process value” display appears, choose “Set as 4mA value” then press ENTER. 8 When the display in Step 6 appears, choose Exit, then press ENTER. Return the loop to automatic control. 9 10 Press HOME to return to the “Online” display. From “Online” menu, step through the following menu selections: • Device setup • Process variables 11 At “Process variables” display, read 0% output for corresponding zero line pressure plus head pressure H. Check that milliammeter reading is 4 mA (0%) output. 12 Close plug C 13 Open valve D to begin measuring process line pressure. 14 Take communicator and milliammeter readings to check that output signal does correspond to applied line pressure. If readings do not correspond, check that transmitter has been installed correctly. If applicable, blow down piping to be sure no foreign matter is entrapped in it. Check communicator and milliammeter readings again. If readings are still not correct, verify transmitter’s configuration data and change its range setting if needed. 15 72 Remove communicator and milliammeter from loop. ST 3000 HART Transmitter Release 300 User Manual 6/05 7— Start-up - Liquid Level Measurement – Vented Tank Liquid Level Measurement – Vented Tank Procedure The procedure in Table 31 outlines the steps for starting up a differential pressure (DP) type transmitter in a liquid level measurement application for a vented tank with a dry reference leg. Refer to Figure 30 for the piping arrangement identification and Figure 27 for typical communicator and meter connections. Valve A Plug C Tap location at the minimum level to be measured To HP connection on meter body H Differential Pressure Transmitter LP Vent Figure 30 Typical Piping Arrangement for Liquid Level Measurement with DP Type Transmitter and Vented Tank ATTENTION For the procedure in Table 31, we are assuming that the tank is empty and the piping arrangement includes a block-off valve. Table 31 Starting Up DP Transmitter for Liquid Level Measurement in Vented Tank Step Action 1 Connect communicator across loop wiring; turn it on and establish communications. If possible, locate communicator where you can also view receiver instrument in control loop. If you want to verify transmitter output, connect a precision milliammeter or voltmeter in loop to compare readings. Refer to Figure 27 for sample communicator and meter connections in a typical analog loop with a differential pressure-type transmitter. 2 Close block-off valve A. Refer to Figure 30 for sample piping arrangement. 6/05 ST 3000 HART Transmitter Release 300 User Manual 73 7— Start-up - Liquid Level Measurement – Vented Tank Step 3 Action Open plug C. Allow system to stabilize at head pressure. 4 At “Online” menu, read present LRV setting. 5 From “Online” menu, step through the following menu selections: • Device setup • Diag/Service • Calibration • Apply values You will be warned to remove the loop from automatic control. After doing so, press OK to continue. 6 When the following display appears, ST3000: PT 3011 Set the: 1 2 3 4mA 20mA Exit ABORT ENTER choose 4mA, then press ENTER. A display will prompt you to apply new 4 mA input. Press OK. 7 When “Current applied process value” display appears, choose “Set as 4mA value” then press ENTER. 8 When the display in Step 6 appears, choose Exit, then press ENTER. Return the loop to automatic control. 9 10 Press HOME to return to the “Online” display. From “Online” menu, step through the following menu selections: • Device setup • Process variables 11 At “Process variables” display, read 0% output for corresponding empty tank pressure plus head pressure H. Check that milliammeter reading is 4 mA (0%) output. 12 Close plug C. 13 Open valve A to begin measuring tank pressure. Leave LP side vented to atmosphere. ATTENTION If the URV was calculated on the approximate density of the liquid and/or tank height, the exact URV can be set by filling the tank to the desired full scale level and then setting the URV through the communicator. See Range Values in Section 6 for details. 74 ST 3000 HART Transmitter Release 300 User Manual 6/05 7— Start-up - Liquid Level Measurement – Pressurized Tank Step Action 14 Take communicator and milliammeter readings to check that output signal does correspond to applied tank level pressure. If readings do not correspond, check that transmitter has been installed correctly. If applicable, blow down piping to be sure no foreign matter is entrapped in it. Check communicator and milliammeter readings again. If readings are still not correct, verify transmitter’s configuration data and change its range setting, if needed. 15 Remove communicator and milliammeter from loop. Liquid Level Measurement – Pressurized Tank Procedure The procedure in Table 32 outlines the steps for starting up a differential pressure (DP) type transmitter in a liquid level measurement application for a pressurized tank with a liquid-filled (wet) reference leg. Refer to Figure 31 for the piping arrangement identification and Figure 27 for typical communicator and meter connections. Valve B Plug D Plug C at zero level Valve A H1 Tap location at the minimum level to be measured h Differential Pressure Transmitter HP side of transmitter Figure 31 Typical Piping Arrangement for Liquid Level Measurement with DP Type Transmitter and Pressurized Tank. 6/05 ST 3000 HART Transmitter Release 300 User Manual 75 7— Start-up - Liquid Level Measurement – Pressurized Tank ATTENTION For the procedure in Table 32, we are assuming: • The tank is empty and the reference leg is filled. • The high pressure (HP) side of the transmitter is connected to the wet reference leg. Note that the transmitter will work if the HP side is connected to the bottom of the tank, but not within the guaranteed accuracy specifications. • The transmitter is mounted below the zero level of the tank, so “h” is greater than zero. If h equals zero, plug C is eliminated from the piping and the LP vent is opened instead. Table 32 Starting Up DP Transmitter for Liquid Level Measurement in Pressurized Tank Step Action 1 Connect communicator across loop wiring; turn it on and establish communications. If possible, locate communicator where you can also view receiver instrument in control loop. If you want to verify transmitter output, connect a precision milliammeter or voltmeter in loop to compare readings. Refer to Figure 27 for sample communicator and meter connections in a typical analog loop with a differential pressure-type transmitter. 2 Close block-off valves A and B. Refer to Figure 31 for sample piping arrangement. 3 Open plugs C and D. Allow system to stabilize at head pressure. 4 At “Online” menu, read present LRV setting. 5 From “Online” menu, step through the following menu selections: • Device setup • Diag/Service • Calibration • Apply values You will be warned to remove the loop from automatic control. After doing so, press OK to continue. 6 When the following display appears, ST3000: PT 3011 Set the: 1 2 3 4mA 20mA Exit ABORT ENTER choose 4mA, then press ENTER. A display will prompt you to apply new 4 mA input. Press OK. 76 ST 3000 HART Transmitter Release 300 User Manual 6/05 7— Start-up - Liquid Level Measurement – Pressurized Tank Step Action 7 When “Current applied process value” display appears, choose “Set as 4mA value” then press ENTER. 8 When the display in Step 6 appears, choose Exit, then press ENTER. Return the loop to automatic control. 9 10 Press HOME to return to the “Online” display. From “Online” menu, step through the following menu selections: • Device setup • Process variables 11 At “Process variables” display, read 0% output for corresponding empty tank pressure plus head pressure H1. Check that milliammeter reading is 4 mA (0%) output. 12 • If you cannot fill tank, then go to Step 13 • If you can fill tank to desired full-scale level, then go to Step 14 13 Key in URV that is equal to full tank pressure. See Range values in Section 6 for details on keying in a range value. Go to Step 24 14 Close plugs C and D. 15 Open valves A and B. Fill tank to desired full scale level. 16 At “Online” menu (if applicable, press HOME to get there), read present URV setting. 17 From “Online” menu, step through the following menu selections: • Device setup • Diag/Service • Calibration • Apply values You will be warned to remove the loop from automatic control. After doing so, press OK to continue. 18 When the following display appears, ST3000: PT 3011 Set the: 1 2 3 4mA 20mA Exit ABORT ENTER choose 20mA, then press ENTER. A display will prompt you to apply new 20 mA input. Press OK. 19 6/05 When “Current applied process value” display appears, choose “Set as 20mA value” then press ENTER. ST 3000 HART Transmitter Release 300 User Manual 77 7— Start-up - Pressure or Liquid Level Measurement with GP Transmitter Step 20 Action When the display in Step 18 appears, choose Exit, then press ENTER. Return the loop to automatic control. 21 Press HOME to return to the “Online” display. 22 From “Online” menu, step through the following menu selections: • Device setup • Process variables 23 At “Process variables” display, read 100% output for corresponding full tank pressure applied. Check that milliammeter reading is 20 mA (100%) output. 24 Take communicator and milliammeter readings to check that output signal does correspond to empty and full tank pressures. If readings do not correspond, check that transmitter has been installed correctly. If applicable, blow down piping to be sure no foreign matter is entrapped in it. Check communicator and milliammeter readings again. If readings are still not correct, verify transmitter’s configuration data and change its range setting, if needed. Ranging the transmitter in this way makes it reverse acting. 25 Remove communicator and milliammeter from loop. Pressure or Liquid Level Measurement with GP Transmitter Procedure The procedure in Table 33 outlines the steps for starting up a gauge pressure (GP) type transmitter in a pressure or liquid level measurement application. Refer to Figure 32 and Figure 33 for the piping arrangement identification and Figure 27 for typical communicator and meter connections.. Block-off valve no.1 Pipe Plug Union Gauge Pressure Transmitter Process Block-off valve no.2 Tee connector Figure 32 Typical Piping Arrangement for Pressure Measurement with GP Type Transmitter 78 ST 3000 HART Transmitter Release 300 User Manual 6/05 7— Start-up - Pressure or Liquid Level Measurement with GP Transmitter To Process Head connection on meter body Block-off valve Gauge Pressure Transmitter Tap location at the minimum level to be measured Figure 33 Typical Piping Arrangement for Liquid Level Measurement with GP Type Transmitter. ATTENTION For the procedure in Table 33, we are assuming that piping arrangement includes a block-off valve and a Tee-connector. If your piping does not include a Tee-connector, you can only verify that the input and output readings correlate. Table 33 Starting Up GP Transmitter for Pressure or Liquid Level Measurement Step Action 1 Connect communicator across loop wiring; turn it on and establish communications. If possible, locate communicator where you can also view receiver instrument in control loop. If you want to verify transmitter output, connect a precision milliammeter or voltmeter in loop to compare readings. Refer to Figure 27 for sample communicator and meter connections in a typical analog loop with a differential pressure-type transmitter. 2 Close block-off valve. Refer to Figure 32 or Figure 33 for sample piping arrangement. 3 Remove plug from Tee-connector to vent it to atmosphere, if applicable. Allow system to stabilize at static pressure. 4 At “Online” menu, read applied input pressure (PV) which should be zero. Also read PV analog output which should be 4 mA to correspond with 0% output. 5 Optional (read output in % of range): From “Online” menu, step through the following menu selections: • Device setup • Process variables At “Process variables” display, read 0% output for corresponding input pressure. Check that milliammeter reading is 4 mA (0%) output 6/05 ST 3000 HART Transmitter Release 300 User Manual 79 7— Start-up - Pressure or Liquid Level Measurement with GP Transmitter Step 6 Action If communicator and milliammeter readings are zero (4 mA), then go to Step 9. If communicator and milliammeter readings are not zero (4 mA) and Tee-connector is level with transmitter, then go to Step 7 If communicator and milliammeter readings are not zero (4 mA) and Tee-connector is above transmitter, then go to Step 8 7 From “Online” menu (if applicable, press HOME to get there), step through the following menu selections: • Device setup • Diag/Service • Calibration • Zero trim Under “Zero trim” do the following when prompted: • Remove the loop from automatic control, then press OK. • Press OK when warned that this will affect sensor calibration. • Press OK when “Apply 0 input to sensor.” display appears. You will receive a message telling you that the sensor input is stabilizing, then the sensor zero succeeded. • Return the loop to automatic control, then press OK. Go to Step 9. 8 From “Online” menu (if applicable, press HOME to get there), step through the following menu selections: • Device setup • Diag/Service • Calibration • Apply values You will be warned to remove the loop from automatic control. After doing so, press OK to continue. When the following display appears, ST3000: PT 3011 Set the: 1 2 3 4mA 20mA Exit ABORT ENTER choose 4mA, then press ENTER. A display will prompt you to apply new 4 mA input. Press OK. When “Current applied process value” display appears, choose “Set as 4mA value” then press ENTER. 80 ST 3000 HART Transmitter Release 300 User Manual 6/05 7— Start-up - Pressure Measurement with AP Step Action 8, cont’d When the display above appears, choose Exit, then press ENTER. Return the loop to automatic control. 9 Close Tee-connector and slowly open block-off valve to apply process pressure to transmitter. 10 Take communicator and milliammeter readings to check that output signal does correspond to zero and full-scale pressures. If readings do not correspond, check that transmitter has been installed correctly. If applicable, blow down piping to be sure no foreign matter is entrapped in it. Check communicator and milliammeter readings again. If readings are still not correct, verify transmitter’s configuration data and change its range setting if needed. 11 Remove communicator and milliammeter from loop. Pressure Measurement with AP Procedure The procedure in Table 34 outlines the steps for starting up an absolute pressure (AP). type transmitter in a pressure measurement application. Refer to Figure 34 for the piping arrangement identification and Figure 27 for typical communicator and meter connections. Shut-off valve no.1 Pipe Plug Union Absolute Pressure Transmitter Shut-off valve no.2 Process Tee connector For additional overrrange protection, use Sprague engineering type gauge saver or Fairchild model 95 gauge guard (style 1) Figure 34 Typical Piping Arrangement for Pressure Measurement with AP Type Transmitter 6/05 ST 3000 HART Transmitter Release 300 User Manual 81 7— Start-up - Pressure Measurement with AP ATTENTION For AP transmitters, you can only verify that the input and output readings correlate. Table 34 Starting Up AP Transmitter for Pressure Measurement. Step 1 Connect communicator across loop wiring; turn it on and establish communications. If possible, locate communicator where you can also view receiver instrument in control loop. If you want to verify transmitter output, connect a precision milliammeter or voltmeter in loop to compare readings. Refer to Figure 27 for sample communicator and meter connections in a typical analog loop. 2 Set process pressure to zero level, if possible. Allow system to stabilize at zero pressure. 3 At “Online” menu, read applied input pressure (PV) which should be zero level. Also read PV analog output which should be 4 mA to correspond with 0% output. 4 Optional (read output in % of range): Read barometric pressure and confirm with local source, (for example, weather station, airport, or other reference). 5 From “Online” menu, step through the following menu selections: • Device setup • Process variables 6 At “Process variables” display, read output. Compare local reference pressure with transmitter in % of span. Check that milliammeter reading corresponds to output. 7 Take communicator and milliammeter readings to check that output signal does correspond to zero and full-scale pressures. If readings do not correspond, check that transmitter has been installed correctly. If applicable, blow down piping to be sure no foreign matter is entrapped in it. Check communicator and milliammeter readings again. If readings are still not correct, verify transmitter’s configuration data and change its range setting if needed. 8 82 Remove communicator and milliammeter from loop. ST 3000 HART Transmitter Release 300 User Manual 6/05 7— Start-up - Liquid Level Measurement with DP Transmitter with Remote Seals Liquid Level Measurement with DP Transmitter with Remote Seals Procedure The procedure in Table 35 outlines the steps for starting up a differential pressure (DP) type transmitter with remote diaphragm seals in a liquid level measurement application.. Refer to Figure 35 for the piping arrangement identification and Figure 27 for typical communicator and meter connections. LP Side Full Level Differential Pressure Transmitter with remote seals H2 Fixed Ref. Leg Variable Head H1 Zero Level (empty) HP Side Figure 35 Typical Piping Arrangement for Liquid Level Measurement with DP Type Transmitter with Remote Seals ATTENTION For the procedure in Table 35, we are assuming that • The tank is empty and the remote seal flanges are installed at their final positions. • The DP transmitter has its high pressure (HP) side connected to the tank’s lower flange and low pressure (LP) side connected to the upper flange. Table 35 Starting Up DP Transmitter with Remote Seals for Liquid Level Measurement Step Action 1 Connect communicator across loop wiring; turn it on and establish communications. If possible, locate communicator where you can also view receiver instrument in control loop. If you want to verify transmitter output, connect a precision milliammeter or voltmeter in loop to compare readings. Refer to Figure 27 for sample communicator and meter connections in a typical analog loop with a differential pressure-type transmitter. 6/05 ST 3000 HART Transmitter Release 300 User Manual 83 7— Start-up - Liquid Level Measurement with DP Transmitter with Remote Seals Step 2 Action • If you cannot empty tank, then go to Step 3. • If you can empty tank, then go Step 4. 3 Key in LRV that is equal to empty tank pressure. See Section 6.7 in this manual for details on keying in a range value. Go to Step 7. You can use this formula to calculate LRV in inH2O. LRV = (H2 x Sf) x –1 H2 = Height of fixed reference leg in inches. Sf = Specific gravity of remote seal fill fluid. The LRV calculation must be multiplied by –1 since pressure in on the low side of the meter body. EXAMPLE: If H2 equaled 12 feet and the fill fluid was silicone oil, substituting into the formula yields: LRV = (12 ft x 12 in x 0.94) x –1 LRV = –135.36 inH2O ATTENTION The specific gravity of silicone oil fill fluid (DC200) is 0.94 and fluorolube fill fluid (CTFE) is 1.84. 4 If applicable, press HOME to return to “Online” menu. Step through the following menu selections: • Device setup • Diag/Service • Calibration • Apply values You will be warned to remove the loop from automatic control. After doing so, press OK to continue. When the following display appears, ST3000: PT 3011 Set the: 1 2 3 4mA 20mA Exit ABORT ENTER choose 4mA, then press ENTER. A display will prompt you to apply new 4 mA input. Press OK. When “Current applied process value” display appears, choose “Set as 4mA value” then press ENTER. LRV is set to fixed reference leg pressure H2 times density of remote seal fill fluid multiplied by –1 (pressure on low side of meter body). When the display above appears, choose Exit, then press ENTER. Return the loop to automatic control. 84 ST 3000 HART Transmitter Release 300 User Manual 6/05 7— Start-up - Liquid Level Measurement with DP Transmitter with Remote Seals Step 5 Action Press HOME to return to “Online” menu. Read applied input pressure (PV) which should be zero. Also read PV analog output which should be 4 mA to correspond with 0% output. 6 Optional (read output in % of range): From “Online” menu, step through the following menu selections: • Device setup • Process variables At “Process variables” display, read 0% output for corresponding empty tank pressure plus reference pressure H2. Check that milliammeter reading is 4 mA (0%) output. 7 • If you cannot fill tank, then go to Step 8. • If you can fill tank, then go Step 9. 8 Key in URV that is equal to full tank pressure. See Range Values in Section 6 for details on keying in a range value. Go to Step 12. You can use these formulas to calculate URV in inH2O. Span = H1 x SL H1 = Height of variable head in inches. SL = Specific gravity of measured liquid. URV = Span + LRV EXAMPLE: If H1 equaled 10 feet, the measured liquid was water, and the LRV equaled – 135.36 inH2O; substituting into the formulas yields: Span = 10 ft x 12 in x 1.00 Span = 120 inH2O 120 inH2O + –135.36 inH2O –15.36 inH2O URV = URV = ATTENTION The specific gravity of water at 60°F (15.6°C) is 1.00. 9 From “Online” menu (if applicable, press HOME to get there), step through the following menu selections: • Device setup • Diag/Service • Calibration • Apply values You will be warned to remove the loop from automatic control. After doing so, press OK to continue. 6/05 ST 3000 HART Transmitter Release 300 User Manual 85 7— Start-up - Liquid Level Measurement with DP Transmitter with Remote Seals Step 9, cont’d Action When the following display appears, ST3000: PT 3011 Set the: 1 2 3 4mA 20mA Exit ABORT ENTER choose 20mA, then press ENTER. A display will prompt you to apply new 20 mA input. Press OK. When “Current applied process value” display appears, choose “Set as 20mA value” then press ENTER. URV is set to full tank pressure. When the display above appears, choose Exit, then press ENTER. Return the loop to automatic control. 10 Press HOME to return to “Online” menu. With full tank pressure applied, read PV analog output which should be 20 mA to correspond with 100% output. 11 Optional (read output in % of range): From “Online” menu, step through the following menu selections: • Device setup • Process variables At “Process variables” display, read 100% output for corresponding full tank. Check that milliammeter reading is 20 mA (100%) output. 12 Take communicator and milliammeter readings to check that output signal does correspond to empty and full tank pressures. If readings do not correspond, check that transmitter has been installed correctly. If applicable, blow down piping to be sure no foreign matter is entrapped in it. Check communicator and milliammeter readings again. If readings are still not correct, verify transmitter’s configuration data and change its range setting if needed. 13 86 Remove communicator and milliammeter from loop. ST 3000 HART Transmitter Release 300 User Manual 6/05 8— Operation - Introduction 8— Operation Introduction About this section This section identifies how to access typical data associated with the operation of an ST 3000 transmitter. It also includes procedures for: changing the default failsafe direction of the transmitter’s output, changing the read/write access of the transmitter’s configuration database, and saving and/or restoring a transmitter’s configuration database. Accessing Operation Data Summary You can access this data relevant to the operation of the transmitter using a hand-held communicator. Input Failsafe Output Direction Output in % or milliamperes Sensor Temperature Upper and Lower Range Limits Messages Status Table 36 summarizes the steps required to access given operation data from the transmitter. These steps assume that communicator communications have been established with the transmitter. All steps start at the “Online” (or HOME) display. The values shown in displays are for example purposes only. 6/05 ST 3000 HART Transmitter Release 300 User Manual 87 8— Operation - Accessing Operation Data Table 36 Summary of Keystrokes for Operation Data Access What you want to view Present input pressure. What to do Read PV from “Online” display. ST3000: PT 3011 Online 1 2 3 4 5 Device setup PV PV AO PV LRV PV URV –0.00745 inH2O 11.989 mA –12.5 inH2O 12.5 inH2O You may need to select PV and press the right arrow key to view PV value.(See Note.) Present transmitter output in percent. Select: Device setup Process variables Read Pres % rnge from “Process variables” display. ST3000: PT 3011 Process variables 1 2 3 4 Pres % rnge AO SV HELP Present transmitter output in milliamperes. –0.00745 inH2O 49.95% 11.992 mA 23.50 degC HOME Read PV AO from “Online” display. ST3000: PT 3011 Online 1 2 3 4 5 Upper and Lower Range Limits of the transmitter. Device setup PV PV AO PV LRV PV URV –0.00745 inH2O 11.989 mA –12.5 inH2O 12.5 inH2O Press the [>>>] key. Read PV LRL and PV URL from “Range values” display. ST3000: PT 3011 Range values 1 2 3 4 PV LRV PV URV PV LRL PV URL –12.5 inH2O 12.5 inH2O 0.00 inH2O 400.7 inH2O HELP You may need to select PV LRL and PV URL and press the right arrow key to view the values. (See Note.) 88 ST 3000 HART Transmitter Release 300 User Manual 6/05 8— Operation - Accessing Operation Data What you want to view Status of transmitter operation at the present time. What to do Select: Device setup Diag/Service Device status Select either “Critical” or “Non-Critical” from the “Device status” display. Warnings, status messages, and error messages appear on screen as necessary. Refer to Section 11 in this manual for further information. Present failsafe output direction, which depends on the position of the internal failure mode alarm jumper. Select: Device setup Detailed setup Output condition Analog output Read AO Alrm typ from “Analog output” display. ST3000: PT 3011 Analog output 1 2 3 4 5 AO AO Alrm typ Loop test D/A trim Scaled D/A trim HOME HELP Present sensor temperature (±5°C) measured by circuitry in the transmitter’s sensor. 11.990 mA Hi Choose: Device setup Detailed setup Sensors Read SV from “Sensors” display ST3000: PT 3011 Sensors 1 2 3 4 5 PV -0.0134 inH2O PV unit inH2O Sensor information 23.42 degC SV SV unit degC HELP Present information in the message (or scratchpad) area. HOME Choose: Device setup Basic setup Device information Message Read present information in “Message” display. ST3000: PT 3011 Message XXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXX CALIBRATED BY JOE 12 02 98 HELP DEL ESC ENTER Note: Some values for PV, PV LRV and PV URV may not be visible in some displays, (due to the limitations of the communicator display). To view these values you must use the down arrow key to select the value and then press the right arrow key to display the value in detail. 6/05 ST 3000 HART Transmitter Release 300 User Manual 89 8— Operation - Changing Default Failsafe Direction and Write Protect Jumpers Changing Default Failsafe Direction and Write Protect Jumpers Default failsafe direction Transmitters are shipped with a default failsafe direction of upscale. This means that the transmitter’s output will be driven upscale (maximum output) when the transmitter detects a critical status. The upscale failsafe action will drive an analog transmitter’s output to 20.8 mA or a downscale action will drive its output to 3.8 mA. The HART communicator parameter PV AO Alrm Typ identifies the failsafe direction of the transmitter. The parameter indicates failsafe action as either Hi (upscale) or Lo (downscale). Write protect option Transmitters are shipped with a default jumper position for read and write access. This means that the transmitter’s configuration database can be overwritten. Procedure The procedure in Table 37 outlines the steps for cutting the failsafe jumper and/or repositioning the write protect jumper on the transmitter’s Printed Wiring Assembly (PWA). Figure 36 shows the location of the jumpers on the PWA of ST 3000 Release 300 transmitters. ESD HAZARD The nature of the integrated circuitry used in the transmitter’s PWA makes it susceptible to damage by stray static discharges when it is removed from the transmitter. Follow these tips to minimize chances of static electricity damage when handling the PWA. • Never touch terminals, connectors, component leads, or circuits when handling the PWA. • When removing or installing the PWA, hold it by its edges or mounting bracket only. If you must touch the PWA circuits, be sure you are grounded by staying in contact with a grounded surface or wearing a grounded wrist strap. • As soon as the PWA is removed from the transmitter, put it in an electrically conductive bag or wrap it in aluminum foil to protect it. Write Protect Jumper W Printed Wiring Assembly R Read and Write Read Only W 1 Failsafe Direction Jumper Figure 36 Location of Failsafe and Write Protect Jumpers on PWA 90 ST 3000 HART Transmitter Release 300 User Manual 6/05 8— Operation - Changing Default Failsafe Direction and Write Protect Jumpers Table 37 Changing Default Failsafe Direction or Write Protect Jumper Step Action 1 Turn OFF transmitter power. Loosen end-cap lock and unscrew end cap from electronics side of transmitter housing. 2 If equipped with a local smart meter, carefully turn smart meter counterclockwise to remove it from PWA mounting bracket and unplug cable from connector on back of meter assembly. 3 Loosen two retaining screws and carefully pull mounting bracket and PWA from housing. Using the retaining clip, unplug flex tape connector and 2-wire power connector from PWA, and remove PWA. See figure. Connectors Retaining Clip PWA Electronics Housing ATTENTION The PWA board has components on both sides. The failsafe and write protect jumpers are located on the side with the most components, which is also the same side as the flex tape and power connector pins. 4 With the PWA component side (from which you unplugged the flex tape and power connectors) facing you and referring to Figure 36, locate • Failsafe jumper (W1). If you want to change the failsafe action from upscale to downscale, cut jumper in half with a small wire cutter. • Write protect jumper (W2). If you want to change read and write access to read only, move jumper to the R position. 5 Reverse steps 2 and 3 to reassemble mounting bracket and PWA in transmitter housing. ATTENTION Be sure to orient local smart meter for proper viewing through end-cap window. You can rotate the meter mounting orientation in 90 degree increments. 6/05 6 We recommend that you lubricate end-cap O-ring with silicon grease such as Dow Corning #33 or equivalent before you replace end cap. 7 Turn ON transmitter power. ST 3000 HART Transmitter Release 300 User Manual 91 8— Operation - Writing Data in the Message Area Writing Data in the Message Area The message area is a 32-character field containing such information as transmitter location, service, record, scratchpad, etc. This data can be entered using the communicator. The procedure in Table 38 outlines the steps for entering a sample message. This procedure assumes that communicator communications have been established with the transmitter. Table 38 Writing Data in the Message Area Step 1 Action Starting at the “Online” menu, choose (by highlighting and pressing the right arrow key) the following menu selections: • Device setup • Basic setup • Device information • Message A display similar to the one below will appear. ST3000: PT 3011 Message XXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXX CALIBRATED BY JOE 12 02 98 HELP 2 DEL ESC ENTER Using the alphanumeric keypad, enter desired message. What you are entering will overwrite the previous message in the highlighted area. If you make a mistake, press DEL to delete character beneath blinking cursor. Refer to “Making changes” in Section 6 for information on using the alphanumeric keypad and alpha position indicator arrow keys. 92 3 Press ENTER to save data in message area. (If you press ESC, you will exit message area without saving change.) 4 When all desired changes have been made, press SEND to download changes from the communicator memory to the transmitter. ST 3000 HART Transmitter Release 300 User Manual 6/05 8— Operation - Saving and Restoring a Configuration Database Saving and Restoring a Configuration Database Background If it ever becomes necessary to replace a damaged transmitter with a spare, you can save the configuration database from the damaged transmitter to the memory module or data pack installed in the communicator, then restore (or send) the saved configuration database from that memory to the spare transmitter. In fact, you can restore the saved configuration database in any number of transmitters as long as you change the tag number (ID) in the restored database. Figure 37 shows a graphic summary of the save and restore database function. Saved Configuration Database Pressure unit Pres damp Pres URV Pres LRV Pres xfer fnctn Temp unit Tag Message Restored Configuration Database inH2O 0.48 s 400 inH2O 0 inH2O Linear degC PT3011 Tank Pressure Pressure unit Pres damp Pres URV Pres LRV Pres xfer fnctn Temp unit Tag Message Memory Module or Data Pack Working Memory Working Memory SEND SAVE ST 3000 inH2O 0.48 s 400 inH2O 0 inH2O Linear degC PT3011 Tank Pressure Communicator ST 3000 Figure 37 Summary of Save and Restore Database Function 6/05 ST 3000 HART Transmitter Release 300 User Manual 93 8— Operation - Saving and Restoring a Configuration Database Procedures The procedure in Table 39 outlines the steps for saving a configuration database from a transmitter. Table 40 provides the procedure for downloading (sending) a saved configuration database to a transmitter. Table 39 Saving a Configuration Database Step Action 1 Connect communicator across loop wiring for transmitter with configuration database to be saved and turn it on. 2 Starting at the “Online” menu, choose SAVE. The Save as . . . screen will appear. ST3000:PT 3011 Save as . . . 1 2 3 HELP Location Name Data Type Module Standard SAVE 3 Select Location and choose the memory location where you want to save the transmitter configuration, (Module, data pack or PC, if available). Press ENTER. 4 Select Name and type in the name of the configuration file. Press ENTER. 5 Select Data Type and choose either Standard or Full (for PC). Press ENTER. 6 Press SAVE. A prompt may say that some variables in this configuration were not marked because they were not read. Press OK. A prompt may ask if you want to overwrite the existing configuration memory. Press YES or NO. The Online screen will appear when save is completed. 7 94 Disconnect communicator from transmitter loop wiring and turn communicator off. ST 3000 HART Transmitter Release 300 User Manual 6/05 8— Operation - Saving and Restoring a Configuration Database Table 40 Downloading a Configuration Database Step Action 1 Connect communicator to loop wiring for transmitter whose database is to be restored and turn it on. 2 Back out to “Offline” display, select Saved Configuration to show the following display. HART Communicator Saved Configuration 1 2 3 Module Contents data pack Contents PC HELP 3 Select the memory location of the saved configuration file and press the right arrow key. 4 Select the file name of the saved configuration. Press the right arrow key. 5 The Saved configuration display appears. HART Communicator Saved Configuration 1 2 3 4 5 Edit Copy to . . . Send Print Delete HELP Select “Send” and press right arrow key. When prompted to put loop into manual, press OK. The selected configuration is downloaded (sent) to the transmitter’s memory. 6 6/05 Back out to “Offline” display, then choose Online. You can now change the tag number and other configuration data, as required. ST 3000 HART Transmitter Release 300 User Manual 95 - 96 ST 3000 HART Transmitter Release 300 User Manual 6/05 9— Maintenance - Introduction 9— Maintenance Introduction About this section This section provides information about preventive maintenance routines and replacing damaged parts. The topics covered in this section are: Preventive maintenance of the meter body barrier diaphragms and process piping to the transmitter. Replacement of damaged parts such as the transmitter PWA and meter body. Preventive Maintenance Maintenance routines and schedules The ST 3000 transmitter itself does not require any specific maintenance routine at regularly scheduled intervals. However, you should consider carrying out these typical inspection and maintenance routines on a schedule that is dictated by the characteristics of the process medium being measured and whether blowdown facilities or purge systems are being used. Check piping for leaks. Clear the piping of sediment or other foreign matter. Clean the transmitter’s pressure chambers including the barrier diaphragms. Inspecting and Cleaning Barrier Diaphragms Depending on the characteristics of the process medium being measured, sediment or other foreign particles may collect in the process head cavity/chamber and cause faulty measurement. In addition, the barrier diaphragm or diaphragms in the transmitter’s meter body may become coated with a residue from the process medium. The latter is also true for external diaphragms on flange mount and remote seal type transmitters. In most cases, you can readily remove the process head or heads from the transmitter’s meter body to clean the process head cavity and inspect the barrier diaphragm or diaphragms. For flange mount and remote seal diaphragms, you may only need to run a purge line in the tank to rinse off the face of the diaphragm. Procedure The procedure in Table 41 outlines the general steps for inspecting and cleaning barrier diaphragms. You may have to modify the steps to meet your particular process or transmitter model requirements. Figure 38 shows an exploded view of a DP transmitter’s meter body for reference. 6/05 ST 3000 HART Transmitter Release 300 User Manual 97 9— Maintenance - Inspecting and Cleaning Barrier Diaphragms Table 41 Inspecting and Cleaning Barrier Diaphragms Step Action 1 Close all valves and isolate transmitter from process. Open vent in process head to drain fluid from transmitter’s meter body, if required. ATTENTION We recommend that you remove the transmitter from service and move it to a clean area before taking it apart. 2 Remove nuts from bolts that hold process head or heads to meter body. Remove process heads and bolts. See Figure 38. 3 Remove O-ring and clean interior of process head using soft bristle brush and suitable solvent. 4 Inspect barrier diaphragm for any signs of deterioration or corrosion. Look for possible residue and clean if necessary. If diaphragm is dented, has distorted convolutions or radial wrinkles, performance may be affected. Contact TAC for assistance. 5 Replace O-ring. ATTENTION • We recommend that you install a new O-ring whenever a process head is removed for cleaning. • The process head for a GP or an AP transmitter with single-head design has two O-ring grooves. A large one which is 2 inches (50.8 mm) in diameter and a small one which is 1.3 inches (33 mm) in diameter as shown in the following illustration. On high pressure model STG180, GP transmitters, use the small O-ring in the smaller/inner groove. On other models of GP and AP transmitters, use a large O-ring in the larger/outer groove. Never use both O-rings together. Larger O-ring groove for lower pressure applications Smaller O-ring groove for high pressure applications 22518 GP/AP Process Head • For process heads of a GP or AP transmitter with dual-head design, see illustration for differential pressure transmitters in Figure 38. 6/05 ST 3000 HART Transmitter Release 300 User Manual 98 9— Maintenance - Inspecting and Cleaning Barrier Diaphragms Step Action 6 Coat threads on process head bolts with anti-seize compound such as “Neverseize” or equivalent. 7 Replace process head or heads and bolts. Finger tighten nuts. 8 Use a torque wrench to gradually tighten nuts to torque rating shown in Table 42, in sequence shown in following illustration. Tighten head bolts in stages of 1/3 full torque, 2/3 full torque, and then full torque. Always tighten head bolts in sequence shown and in these stages: 1. 1/3 full torque 2. 2/3 full torque 3. Full torque 9 1 3 4 2 Return transmitter to service. CAUTION Do not exceed the overload rating when placing the transmitter back into service or during cleaning operations. See Overpressure ratings in Section 3 of this manual. Nuts O-ring Bolts Process head O-ring Center section Process head Figure 38 Disassembly of DP Transmitter Process Heads from Meter Body 6/05 ST 3000 HART Transmitter Release 300 User Manual 99 9— Maintenance - Replacing Printed Wiring Assembly (PWA) Torque ratings Table 42 lists process head bolt torque ratings for given transmitter type. Table 42 Process Head Bolt Torque Ratings Meter Body Type Process Head Bolting Size Draft Range Transmitter 7/16 x 14 UNC 7/16 x 20 UNF M12 x 1.75 All Other DP, GP and AP Transmitters M12 x 1.75 7/16 x 20 UNF 7/16 x 14 UNC 3/8 x 16 UNC M8 x 1.25 5/16 x 18 UNC Carbon Steel – Standard; no option specified 20,3 N-m +/- 1,0 N-m [15.0 Lb-Ft +/- 0.8 Lb-Ft] NA B7M Bolting [“B7” Option] Bolting Type Stainless Steel NACE [“CR” Option] 316 Stainless Steel Non-NACE [“SS” Option] 20,3 N-m +/- 1,0 N-m 20,3 N-m +/- 1,0 N-m 20,3 N-m +/- 1,0 N-m [15.0 Lb-Ft +/- 0.8 Lb-Ft] [15.0 Lb-Ft +/- 0.8 Lb-Ft] [15.0 Lb-Ft +/- 0.8 Lb-Ft] NA 25,8 N-m +/- 1,3 N-m NA [19.0 Lb-Ft +/- 1.0 Lb-Ft] NA NA NA 25,8 N-m +/- 1,3 N-m [19.0 Lb-Ft +/- 1.0 Lb-Ft] 63,7 N-m +/- 3,2 N-m NA [47.0 Lb-Ft +/- 2.4 Lb-Ft] NA NA NA 63,7 N-m +/- 3,2 N-m [47.0 Lb-Ft +/- 2.4 Lb-Ft] 67,8 N-m +/- 3,4 N-m 48,8 N-m +/- 2,4 N-m 56,9 N-m +/- 2,8 N-m [50.0 Lb-Ft +/- 2.5 Lb-Ft] [36.0 Lb-Ft +/- 1.8 Lb-Ft] [42.0 Lb-Ft +/- 2.1 Lb-Ft] 39,3 N-m +/- 2,0 N-m NA 39,3 N-m +/- 2,0 N-m [29 Lb-Ft +/- 1.5 Lb-Ft] [29 Lb-Ft +/- 1.5 Lb-Ft] 27,1 N-m +/- 1,4 N-m NA NA [20.0 Lb-Ft +/- 1.0 Lb-Ft] NA NA 20,3 N-m +/- 1,0 N-m [15.0 Lb-Ft +/- 0.8 Lb-Ft] NA NA 56,9 N-m +/- 2,8 N-m [42.0 Lb-Ft +/- 2.1 Lb-Ft] 39,3 N-m +/- 2,0 N-m [29 Lb-Ft +/- 1.5 Lb-Ft] NA 20,3 N-m +/- 1,0 N-m [15.0 Lb-Ft +/- 0.8 Lb-Ft] Replacing Printed Wiring Assembly (PWA) About the PWA Electronics Board The circuitry in the ST 3000 Release 300 transmitters is of the single PWA design. The PWA contains connectors for the flex-tape conductor from the sensor, the loop power wires and a connector for the optional smart meter cable. The procedure in Table 43 outlines the steps for replacing the PWA. Table 43 Replacing PWA Step 1 Action Turn OFF transmitter power. ATTENTION We recommend that you remove the transmitter from service and move it to a clean area before taking it apart.. 2 Loosen end cap lock and unscrew end cap from electronics side of transmitter housing. ESD HAZARD We recommend that you use a ground strap or ionizer when handling the PWA, since electrostatic discharges can damage certain circuit components. 3 6/05 a) If equipped with a local smart meter, carefully turn smart meter counterclockwise to remove it from PWA mounting bracket and unplug cable from connector on back of meter ST 3000 HART Transmitter Release 300 User Manual 100 9— Maintenance - Replacing Printed Wiring Assembly (PWA) Step Action assembly. b) Loosen two retaining screws and carefully pull mounting bracket and PWA from housing. c) Using the retaining clip, unplug flex tape connector and 2-wire power connector from PWA, and remove PWA. Transmitter End Caps PWA and Mounting Bracket Flex-Tape Connector Local Smart Meter Power Connector Meter Cable 4 • If your transmitter has local smart meter option, then go to Step 5. • If your transmitter does not have local smart meter option, then go to Step 7. 5 Note orientation of mounting bracket on PWA (side without cable connectors). Unplug meter cable from connector on PWA. Remove screw retainers from other side of mounting screws so you can remove screws and mounting bracket from PWA. Set PWA aside. Mounting Screws PWA Connector Side 1 Meter cable is installed between PWA and mounting bracket. W R W Meter Cable 6 6/05 Restraining Clip Mounting Bracket J4 Meter Connector Orient mounting bracket as noted above with meter cable still located in slot on its right-hand side, install mounting screws through bracket and replacement PWA, and install retainers to hold screws in place. Plug meter cable into connector J4 on PWA and be sure cable is still ST 3000 HART Transmitter Release 300 User Manual 101 9— Maintenance - Replacing Printed Wiring Assembly (PWA) Step Action under restraining clip on front of bracket. Go to Step 9. 7 Note orientation of mounting bracket on PWA (side without cable connectors). Remove screw retainers from other side of mounting screws so you can remove screws and mounting bracket from PWA. Set PWA aside. Mounting Screws 1 PWA Connector Side W R W Mounting Bracket 8 Orient mounting bracket as noted above, install mounting screws through bracket and replacement PWA, and install retainers to hold screws in place. 9 Reverse actions in Steps 2 and 3, as applicable, to install PWA and bracket to transmitter housing. We recommend that you lubricate end-cap O-ring with silicon grease such as Dow Corning #33 or equivalent before you replace end cap. 10 Recalibrate transmitter. Refer to Section 10 for proper procedure. ATTENTION Be sure to orient local smart meter for proper viewing through end-cap window. You can rotate the meter mounting orientation in 90 degree increments. 6/05 11 Return transmitter to service and turn ON power. 12 If applicable, verify local smart meter configuration data. Reconfigure selected engineering units and lower and upper display range values as required. (See Appendix A for details.) ST 3000 HART Transmitter Release 300 User Manual 102 9— Maintenance - Replacing Meter Body Replacing Meter Body You can replace the complete meter body including process heads or only the meter body on selected DP, GP and AP transmitters by using the existing process head(s). Use the procedure in Table 44 to install a meter body only. Table 44 Replacing Meter Body Only Step Action 1 Complete first 3 Steps in Table 43, as applicable, to remove PWA. 2 Use 4 mm size hex wrench to completely loosen set screw outside housing. Set Screw Process Head Process Head Meter Body 3 Carefully turn complete meter body counterclockwise to unscrew it from electronics housing. 4 Remove nuts from bolts that hold process head or heads to center section. Remove process heads and bolts 5 Remove O-ring and clean interior of process head using soft bristle brush and suitable solvent. 6 Replace O-ring. ATTENTION The process head for a GP or an AP transmitter with single-head design has two O-ring grooves. A large one which is 2 in (50.8 mm) in diameter and a small one which is 1.3 in (33 mm) in diameter as shown in the following illustration. On high-pressure, model STG180, GP transmitters, be sure to use a small O-ring in the smaller/inner groove. On other models of GP and AP transmitters, use a large O-ring in the larger/outer groove. Never use both O-rings together. 6/05 ST 3000 HART Transmitter Release 300 User Manual 103 9— Maintenance - Replacing Meter Body Step Action 6, cont’d Smaller O-ring groove for high pressure applications Larger O-ring groove for lower pressure applications 22518 GP/AP Process Head • For process heads of a GP or AP transmitter with dual-head design, see detail illustration for differential pressure transmitters in Figure 38. 7 Coat threads on process head bolts with anti-seize compound such as “Neverseize” or equivalent. 8 Carefully assemble process head or heads and bolts to new meter body. Finger tighten nuts. Typical Series 100 DP Transmitter Meter Body Nuts Flex Tape O-ring O-ring HP S Bolts IDE Process head LP S ID E Meter Body Process head 6/05 ST 3000 HART Transmitter Release 300 User Manual 104 9— Maintenance - Replacing Meter Body Step Action 9 Use a torque wrench to gradually tighten nuts to torque rating shown in Table 42 in sequence shown in following illustration. Tighten head bolts in stages of 1/3 full torque, 2/3 full torque, and then full torque. Always tighten head bolts in sequence shown and in these stages: 1. 1/3 full torque 2. 2/3 full torque 3. Full torque 1 3 4 2 22519 10 Feed flex tape on new meter body through neck of housing and screw new meter body into housing until bottom of header portion of center section is approximately flush with neck of electronics housing. 11 Tighten outside set screw to be sure it is fully seated in slot in header. Loosen set screw half turn, rotate housing to desired position and tighten set screw. 12 Reverse actions in Steps 2 and 3 in Table 43, as applicable, to return PWA and bracket to transmitter housing. We recommend that you lubricate end-cap O-ring with silicon grease such as Dow Corning #33 or equivalent before you replace end cap. 13 Recalibrate transmitter. Refer to Section 10 for proper procedure. ATTENTION Be sure to orient Local Smart Meter for proper viewing through end-cap window. You can rotate the meter mounting orientation in 90 degree increments. 6/05 14 Return transmitter to service and turn ON power 15 Verify transmitter’s configuration data. Restore saved database, if applicable. ST 3000 HART Transmitter Release 300 User Manual 105 - 6/05 ST 3000 HART Transmitter Release 300 User Manual 106 10— Calibration - Introduction 10— Calibration Introduction About this section This section provides information about calibrating the transmitter’s analog output and measurement range. It also covers the procedure for resetting calibration to default values as a quick alternative to measurement range calibration. This section includes these topics. How to calibrate the transmitter’s analog output circuit using the communicator How to perform a two-point calibration of the transmitter How to perform a corrects reset to return the transmitter calibration to its default values. Overview About calibration The ST 3000 Smart Transmitter does not require recalibration at periodic intervals to maintain accuracy. If a recalibration is required, we recommend that you do a bench calibration with the transmitter removed from the process and located in a controlled environment to get the best accuracy. Before you recalibrate the transmitter’s measurement range, you must calibrate the transmitter’s analog output signal. See Table 44 for procedure. You can also use the communicator to reset the calibration data to default values, if they are corrupted, until the transmitter can be recalibrated. See Table 46 in this section for details. ATTENTION All procedures in this manual assume a transmitter poll address of 0 (zero). See Section 6, for information about poll address. Equipment Required ATTENTION Depending upon the calibration you choose, you may need any of the following test equipment to accurately calibrate the transmitter: • Digital voltmeter or milliammeter with 0.02% accuracy or better • HART hand-held communicator • Calibration-standard pressure source with a 0.02% accuracy • 250 ohm resistor with 0.01% accuracy or better. 6/05 ST 3000 HART Transmitter Release 300 User Manual 107 10— Calibration - Calibrating Analog Output Signal Calibrating Analog Output Signal You can calibrate the transmitter’s analog output circuit at its 0 and 100% levels by using the transmitter in its constant-current source mode. It is not necessary to remove the transmitter from service. The procedure in Table 45 shows the steps for calibrating the output signal for a transmitter in the analog mode. ATTENTION You can calculate milliamperes of current from a voltage measurement by using the following equation: voltage dc milliamps = 1000 x resistance Table 45 Calibrating Output Signal for Transmitter in Analog Mode Step 1 Action Connect communicator across loop wiring and turn it on. See Figure 27 in Section 7 for sample test equipment hookup. ATTENTION Be sure the accuracy of the resistor is 0.01% or better for current measurements made by voltage drop. 2 Starting from “Online” menu, choose the following menu selections: • Device setup • Diag/Service • D/A trim You will be prompted to remove the loop from automatic control. After doing so, press OK. When prompts appears, connect a precision milliammeter or voltmeter (0.03% accuracy or better) in loop to check readings. Press OK. 3 The following display prompts will appear: • Setting field device output to 4mA. Press OK. • Enter meter value. Key in meter value, then press ENTER. • Field device output 4.000 mA equal to reference meter? 1 Yes 2 No − − If not equal, select No, press ENTER, then key in new meter value. (Returns to “Enter meter value” prompt until field device output equals reference meter.) If equal, select Yes, press ENTER. Go to Step 4. 6/05 ST 3000 HART Transmitter Release 300 User Manual 108 10— Calibration - Calibrating Range Step 4 Action The following display prompts will appear: • Setting field device output to 20mA. Press OK. • Enter meter value. Key in meter value, then press ENTER. • Field device output 20.000 mA equal to reference meter? 1 Yes 2 No − − If not equal, select No, press ENTER, then key in new meter value. (Returns to “Enter meter value” prompt until field device output equals reference meter.) If equal, select Yes, press ENTER. Prompt notifies you that the field device will be returned to its original output. Calibrating Range The ST 3000 Smart Transmitter has two-point calibration. This means when you calibrate two points in the range, all the points in that range adjust to that calibration. The procedure in Table 46 shows the steps for calibrating a differential pressure (DP) type transmitter to a range of 0 to 200 inH2O for example purposes. This procedure assumes that the transmitter is removed from the process and located in a controlled environment. ATTENTION You must have a precision pressure source with an accuracy of 0.02% or better to do a range calibration. Note that we factory calibrate ST 3000 Smart Transmitters with inches of water ranges using inches of water pressure referenced to a temperature of 39.2˚F (4˚C). Table 46 Calibrating Measurement Range Step 1 Action Connect power supply and communicator to signal terminals on transmitter’s terminal block. Connect precision pressure source to high pressure side of DP type transmitter. See Figure 39 for typical communicator, power supply, and pressure source hookup for calibration. 2 Turn on power supply and allow transmitter to stabilize its operation. 3 Turn on communicator. 4 From “Online” menu, choose the following menu selections: • Device setup • Diag/Service • Calibration • Correct Input LRV You will be prompted to remove the loop from automatic control. After doing so, press OK. 6/05 ST 3000 HART Transmitter Release 300 User Manual 109 10— Calibration - Calibrating Range Step Action 5 When prompted, adjust pressure source to apply pressure equal to LRV (0%), then press OK. 6 When pressure is stable, press OK. When prompted, remove pressure. 7 Choose Correct Input URV. 8 When prompted, adjust pressure source to apply pressure equal to URV (100%), then press OK. 9 When pressure is stable, press OK. When prompted, remove pressure. ST 3000 HART + TEST - SIGNAL + + 24Vdc Power - Supply 250 Ω Low Pressure Head DVM Dead Weight Tester or Precision Pressure Source Communicator NOTE: Polarity of communicator connection does not matter. Figure 39 Typical Range Calibration Hookup 6/05 ST 3000 HART Transmitter Release 300 User Manual 110 10— Calibration - Resetting Calibration Resetting Calibration Background Every ST 3000 transmitter is factory-characterized. The characterization process calculates a mathematical model of the performance of the transmitter’s sensors and stores that data in the transmitter’s memory. Small residual errors result from the sensor data acquisition and modeling process. These errors can be eliminated through calibration, using either a zero offset or a span correction. A Corrects Reset returns the zero and span calibration factors to their default values. The transmitter calculates its output based on the characterization equation alone, without any compensation for the residual errors. A typical zero offset correction is less than 0.1 inches of water (based on a 400 inH2O range) and a typical span correction is less than 0.2% regardless of the range of calibration (down to the point where specification turndown begins). Typical performance of a 400 inH2O transmitter with Corrects Reset can be expressed as: Accuracy = 0.2% + (0.1”/span”) • 100% By calibrating the zero, the typical performance will be 0.2% or better. For transmitter ranges other than 400”, the initial zero offset will be scaled by the ratio of the Upper Range Limit to 400. For example, for a 100 psi transmitter, the initial zero offset can be expressed by: 0.1” • 2768/400 = 0.7” or 0.025 psi. Please note that these are typical values, not hard specifications. Procedure The procedure in Table 47 shows how to reset calibration data to default values in a transmitter using the communicator. Table 47 Resetting Calibration Data Step Action 1 Connect communicator across loop wiring and turn it on. 2 From “Online” menu, choose the following menu selections: • Device setup • Diag/Service • Calibration • Reset Corrects 3 When prompted, remove the loop from automatic control. Press OK. Prompt notifies you that a Reset Corrects is about to occur. Press OK. When message “Reset Corrects OK” appears, press OK. Previous calibration “CORRECTS” are removed and calibration is reset to default values. 4 6/05 When prompted, return the loop to automatic control and press OK. ST 3000 HART Transmitter Release 300 User Manual 111 - 6/05 ST 3000 HART Transmitter Release 300 User Manual 112 11— Troubleshooting - Introduction 11— Troubleshooting Introduction About this section This section identifies diagnostic messages that may appear in the communicator and describes what they mean. An interpretation of diagnostic messages is given and suggestions of the possible cause and corrective action for each message. Procedures are provided for running a status check. This section includes these topics. A summary of the different diagnostic message categories that can be displayed by the communicator. A description of the diagnostic messages and a recommended action to correct the condition or fault. Troubleshooting Overview Diagnostics The communicator and ST 3000 transmitter are constantly running internal diagnostics to monitor the functions and status of the control loop and their communications link. When a diagnostic failure is detected, a corresponding message is generated for the communicator display. Troubleshooting tool Your primary troubleshooting tool is using the communicator for status messages and then interpreting the diagnostic messages. You should also use the communicator to verify the transmitter’s configuration data and check to be sure that your process is operating correctly. To access transmitter diagnostics You access the transmitter diagnostics starting at the “Online” menu of the communicator. You then select: Device setup Diag/Service Device status The Device status menu appears. ST3000:PT 3011 Device status 1 2 HELP Critical Non-Critical SAVE HOME Select “Critical” or “Non-Critical” to view the status of the transmitter’s diagnostics. Device status diagnostics are shown as either ON (in alarm) or OFF (no alarm). 6/05 ST 3000 HART Transmitter Release 300 User Manual 113 11— Troubleshooting - Diagnostic Messages Diagnostic Messages Summary The diagnostic messages can be grouped into one of these three categories: Critical Failures Non-Critical Failures Communication Errors A description of the messages in each category is given in the following paragraphs. Critical failures Table 48 summarizes the critical communicator status message displays. A critical failure drives the transmitter’s output to its failsafe direction—upscale or downscale. Table 48 Summary of Diagnostic Messages for Critical Failures Message Description INVALID DATABASE Database corrupted upon power-up. CHAR PROM FAULT Characterization PROM failure. SUSPECT INPUT Input pressure may be incorrect DAC DIODE FAULT Digital to Analog Converter (DAC) fault NVM FAULT Transmitter Nonvolatile Memory (NVM) fault RAM FAULT Transmitter Random Access Memory (RAM) fault PROM FAULT Transmitter Programmable Read Only Memory (PROM) fault PAC FAULT Currently not implemented. Once a critical fault has been corrected, you must clear the critical status from the transmitter. See Clearing Critical Status later in this section. 6/05 ST 3000 HART Transmitter Release 300 User Manual 114 11— Troubleshooting - Diagnostic Messages Non-critical failures Table 49 summarizes the non-critical communicator status message displays. All communicator functions remain operational during a non-critical failure. Table 49 Summary of Diagnostic Messages for Non-Critical Failures Message Description SENSOR OVER TEMP Meter body temperature is too high. EXCESS ZERO CORR Zero calibration value is too large (shift is larger than characterization). EXCESS SPAN CORR SPAN correction factor is outside the acceptable limits for accurate operation. IN OUTPUT MODE Transmitter is operating as current source. M.B. OVERLOAD OR Input pressure is more than two times greater than the Upper Range Limit of the transmitter. METERBODY FAULT CORRECTS RESET Must recalibrate transmitter to attain required accuracy. NO DAC TEMP COMP No temperature compensation data exists for calculations Other error messages that may appear due to noncompatability of communicator software or transmitter communication mode. Message Description NOTICE: Upgrade 275 software to access new Xmtr functions. Continue with old description? You have connected to a device that has a newer revision of device description than what is in the communicator. In multidrop mode The transmitter poll address is not 0 (zero). You have tried to change the analog output of a transmitter that is in multidrop mode. Communication errors Table 50 summarizes the message displays associated with communication errors. All communicator functions are disabled when a communication error occurs. Table 50 Summary of Diagnostic Messages for Communication Errors Message 6/05 Description Device Disconnected Communication with a device has been interrupted. No Device Found Communicator was unable to establish communications with any device upon power-up. ST 3000 HART Transmitter Release 300 User Manual 115 11— Troubleshooting - Interpreting Messages Interpreting Messages Most of the diagnostic messages that can be displayed on the communicator are listed in alphabetical order in Table 51 along with a description and suggested action to be taken. Table 51 Diagnostic Message Interpretation Table Message Possible Cause What to Do Char PROM Fault Characterization PROM is not functioning correctly. Replace meter body. Corrects Reset All calibration “CORRECTS” were deleted and data was reset to default values. Recalibrate transmitter. See Section 10. DAC Diode Fault Digital to Analog Converter (DAC) fault. Replace electronics module (PWA). Device Disconnected Previously established communication with a transmitter has been lost. Could be a transmitter or loop failure. • Try communicating again. Electronic Fault Electronics module is not functioning properly. Replace electronics module. Do not SAVE data. Excess Span Corr SPAN correction factor is outside acceptable limits. Could be that transmitter was in output mode. • Check input pressure and be • Check that transmitter’s loop integrity has been maintained, that communicator is connected properly, and that loop resistance is at least 250Ω. sure that it matches calibrated range value. • Check meter body. • Do a URV CORRECT procedure. Excess Zero Corr ZERO correction factor is outside acceptable limits. Could be that INPUT was incorrect or transmitter was in output mode during a CORRECT procedure. • Check input pressure and be sure that it matches calibrated range value. • Check meter body. • Do an LRV CORRECT procedure. In multidrop mode The transmitter poll address is not 0 (zero). You have tried to change the analog output of a transmitter that is in multidrop mode. Change “HART mode” of transmitter to analog by changing poll address to 0. In Output Mode Transmitter is operating as a current source. Exit output mode (Loop test)-. Perform Master reset, (or cycle power). Table continued on next page ⇒ 6/05 ST 3000 HART Transmitter Release 300 User Manual 116 11— Troubleshooting - Interpreting Messages Message Possible Cause Transmitter database was incorrect at power-up. Invalid Database What to Do • Try communicating again. • Verify database configuration, Manually update non-volatile memory with each parameter. Pressure input is two times greater than URL of transmitter. M.B. Overload OR Meterbody Fault • Check range and, if required, replace transmitter with one that has a wider range. • Meter body may have been damaged. Check the transmitter for accuracy and linearity. Replace meter body and recalibrate, if needed. No DAC Temp Comp No temperature compensation data exists for calculations. Effect will be minor degradation of ambient temperature influence specifications. Replace electronics module (PWA). No Device Found No response from transmitter. Could be transmitter or loop failure. • Try communicating again. NOTICE: Upgrade 275 software to access new Xmtr functions. Continue with old description? You have connected to a device that has a newer revision of device description than what is in the communicator. Get updated device description for the transmitter installed in the communicator. NVM Fault Transmitter’s nonvolatile memory fault. Replace electronics module (PWA). PAC Fault Currently not implemented. Nothing. PROM Fault Transmitter Programmable Read Only Memory (PROM) fault Replace electronics module (PWA). RAM Fault Transmitter Random Access Memory (RAM) fault. Replace electronics module (PWA). Sensor Over Temp Meter body temperature is too high. Accuracy and life span may decrease if it remains high. Take steps to insulate meter body from temperature source. Suspect Input Input data seems wrong. Could be a process problem, but it could also be a meter body or PWA problem. • Put transmitter in output mode. • Check that transmitter’s loop integrity has been maintained, that communicator is connected properly, and that loop resistance is at least 250Ω. Note: You can continue communicating with the transmitter, but will not have access to full transmitter functions. Diagnostic messages should identify where problem is. If no other diagnostic message is given, condition is most likely meter body related. • Check installation and replace meter body if condition persists. 6/05 ST 3000 HART Transmitter Release 300 User Manual 117 11— Troubleshooting - Clearing Critical Status Clearing Critical Status After a critical failure has been diagnosed and corrected the critical status must be cleared from the transmitter. This can be done by performing a master reset using the communicator. A master reset causes a hardware reset of the transmitter, which actually is the same as cycling the power to the transmitter. Table 52 outlines the steps for resetting the transmitter. Table 52 Resetting the Transmitter Step Action 1 Connect communicator across loop wiring and turn it on. 2 From “Online” menu, choose the following menu selections: • Device setup • Diag/Service • Master reset 3 When prompted, remove the loop from automatic control. Press OK. Prompt notifies you that a Master Reset is about to occur. Press OK. When message “Master reset OK” appears, press OK. Previous calibration “CORRECTS” are removed and calibration is reset to default values. 4 6/05 When prompted, return the loop to automatic control and press OK. ST 3000 HART Transmitter Release 300 User Manual 118 12— Parts List - Replacement Parts 12— Parts List Replacement Parts About this section All individually saleable parts for the various transmitter models are listed in this section. Some parts are illustrated for identification. Parts are identified and listed in the corresponding tables as follows: All individually saleable parts are indicated in each figure by key number callout. For example: 1, 2, 3, and so on. All parts that are supplied in kits are indicated in each figure by key number callout with the letter “K” prefix. For example: K1, K2, K3, and so on. Parts denoted with a “†” are recommended spares. See Table 64 for summary list of recommended spare parts. Figure 40 shows major parts for a given model with reference to parts list figures. 6/05 ST 3000 HART Transmitter Release 300 User Manual 119 12— Parts List - Replacement Parts ST 3000 Release 300 Electronic Housing Assembly: See Figures 42 and 43 Meter Bodies DP Models STD110 STD120 STD125 STD130 STD170 STD904 STD924 STD930 STD974 See Figure 44 44 44 44 44 44,45 44,45 44,45 44,45 Flange Mounted Models STF128 STF132 STF12F STF13F STF14F STF924 STF932 STF92F STF93F Single Head GP Models STG140 STG170 STG180 See Figure 46 46 46 Single Head AP Models STA122 STA140 STA922 STA940 See Figure 46 46 46 46 See Figure 50 50 50 50 50 50 50 50 50 Dual Head GP Models STG944 STG974 See Figure 47 47 Remote Diaphragm Seal Models STR12D LGP Models STR13D STR14G STR14A STR17G STR93D STR94G Attention: No replacement meter body is available for Remote Diaphragm Seal Models. High Temperature Models STG14T STF14T LGP/LAP See Models STG14L STG17L STG18L STG90L STG94L STG97L STG98L STA12L, 92L STA14L, 94L Figure 48 48 48 48 48 48 48 48 48 Flush Mount GP Models STG93P See Figure 49 See Figure 51 51 Figure 40 Major ST 3000 Smart Transmitter Parts Reference. 6/05 ST 3000 HART Transmitter Release 300 User Manual 120 12— Parts List - Replacement Parts 1 3 Angle Mounting Bracket Flat Mounting Bracket 2 4 Figure 41 Major ST 3000 Smart Transmitter Parts Reference. Table 53 Major ST 3000 Smart Transmitter Parts Reference. Key No. Part Number 1 30752770-003 Angle Bracket Mounting Kit for all models except LGP and Flush mount 2 30752770-004 Angle Bracket Mounting Kit for models LGP, Flush mount, STR14G, STR17G, and STR94G 3 51196557-001 Flat Bracket Mounting Kit for all models except LGP and Flush Mount 4 51196557-002 Flat Bracket Mounting Kit for all models LGP, Flush mount, STR14G, STR17G, and STR94G 6/05 Description ST 3000 HART Transmitter Release 300 User Manual Quantity Per Unit 121 12— Parts List - Replacement Parts 4 2 6 1 K1 5 Figure 42 Series 100/900 Electronics Housing - Electronics/Meter End. 1 K1 3/K2 Figure 43 Series 100/900 Electronics Housing - Terminal Block End 6/05 ST 3000 HART Transmitter Release 300 User Manual 122 12— Parts List - Replacement Parts Table 54 Parts Identification for Callouts in Figure 42 and Figure 43 Key No. Part Number 1 30756961-503 End Cap 1 2 30756996-503 End Cap, meter 1 3 51205897-501† 51404078-502† Terminal assembly without lightning protection Terminal assembly with lightning protection 1 4 51309389-501 51309389-502 51309389-503 Local Zero and Span Adjust Only Local Smart Meter Only Local Smart Meter With Zero and Span Adjust 1 5 51309397-502 Electronics Module Assembly (PWA) 1 6 51204038-001 Retaining Clip 1 7 30756997-501 Analog meter 1 K1 30757503-001† Electronics housing seals kit (includes O-rings) K2 51197425-001 Terminal assembly without lightning protection conversion kit (includes screws, cover, and terminal block) Terminal assembly with lightning protection conversion kit (includes screws, cover, and terminal block) 51197425-002 Not Shown 30757504-001 K2 K3 Description Quantity Per Unit Electronics housing hardware kit, DP/I, GP/I, LGP/I (includes screws, gasket, plate, washers, cover terminal, and spacers) K4 K1 K3 K2 K7 K3 K1 K2 K1 K5 K3 K6 1 K6 K5 K8 K1 Figure 44 Series 100 and Series 900 DP Meter Body for Models STD924 & STD930 C, D, G, H, K, and L and STD974 6/05 ST 3000 HART Transmitter Release 300 User Manual 123 12— Parts List - Replacement Parts Table 55 Parts Identification for Callouts in Figure 44. Key No. 1 Description Part Number Quantity Per Unit Specify complete model number from nameplate plus R300 Series 100 replacement meter body without heads 1 Specify complete model number from nameplate plus R300 Series 900 replacement meter body without heads 1 30757104-001 Adapter, meter body to electronics housing 1 30753790-001 Carbon steel bolts and nuts kit Not Shown Bolt, hex head, 7/16-20 UNF, 1.375 inches lg., flange adapter 4 K4 Nut, hex, metric, M12, process heads 4 K8 Bolt, hex head, metric, M12, 90mm lg., process heads 4 2 30753791-002 A286 SS (NACE) bolts and 302/304 SS (NACE) nuts kit Not Shown Bolt, hex head, 7/16-20 UNF, 1.375 inches lg., flange adapter 4 K4 Nut, hex, metric, M12, process heads 4 K8 Bolt, hex head, metric, M12, 90mm lg., process heads 4 30753785-001 St. steel vent/drain and plug kit K1 Pipe plug 4 K2 Vent plug (all except model STD110) 2 K3 Vent bushing (all except model STD110) 2 30753787-001 Monel vent/drain and plug kit K1 Pipe plug 4 K2 Vent plug (all except model STD110) 2 K3 Vent bushing (all except model STD110) 2 30753786-001 Hastelloy C vent/drain and plug kit K1 Pipe plug 4 K2 Vent plug (all except model STD110) 2 K3 Vent bushing (all except model STD110) 2 30753788-003† Process head gasket kit (PTFE material) 30753788-004† Process head gasket kit for (Viton material) K6 Head gasket [For gasket only: 30756445-501 (PTFE, quantity 12) or 30749274-501 (6 Viton head O-rings and 6 Vition flange adapter O-rings)] 6 K7 O-ring 3 K9 Gasket, flange adapter (for gasket only: 30679622-501, 6 Teflon; or 30749274-002, 6 Viton) 6 6/05 ST 3000 HART Transmitter Release 300 User Manual 124 12— Parts List - Replacement Parts Key No. Description Part Number Quantity Per Unit Optional Flange Adapter Kits (two heads) - Not Shown 30754419-002 Flange adapter kit (st. steel flange adapters with carbon steel bolts) 30754419-004 Flange adapter kit (Monel flange adapters with carbon steel bolts) 30754419-018 Flange adapter kit (st. steel flange adapters with 316 st. steel bolts) 30754419-020 Flange adapter kit (Monel flange adapters with 316 st. steel bolts) Not Shown Bolt, hex head, 7/16-20 UNF, 1.375 inches lg., flange adapter 4 K11 Gasket, flange adapter 2 K10 Flange adapter 2 K12 Filter screen 2 K9 30754419-003 Flange adapter kit (Hastelloy C flange adapters with carbon steel bolts) 30754419-019 Flange adapter kit (Hastelloy C flange adapters with 316 st. steel bolts) Not Shown Bolt, hex head, 7/16-20 UNF, 1.375 inches lg., optional flange adapter 4 K11 Gasket, flange adapter 2 K10 Flange adapter 2 K9 Process Head Kits (one head with PTFE head gasket) 30753908-001 Process head assembly kit (Hastelloy C head) 30753908-002 Process head assembly kit (Hastelloy C DIN head) 30753908-003 Process head assembly kit (carbon steel head with side vent/drain) 30753908-004 Process head assembly kit (st. steel head with side vent/drain) 30753908-005 Process head assembly kit (Monel head) 30753908-009 Process head assembly kit (carbon steel head without side vent/drain) 30753908-010 Process head assembly kit (stainless steel head without side vent/drain) 30753908-011 Process head assembly kit (stainless steel DIN head without side vent/drain) 30753908-012 Process head assembly kit (carbon steel head - model STD110 only) 30753908-013 Process head assembly kit (st. steel head - model STD110 only) 30753908-014 Process head assembly kit (carbon steel DIN head - model STD110 only) 30753908-015 Process head assembly kit (st. steel DIN head - model STD110 only) K1 Pipe plug 2 K2 Vent plug 1 K3 Vent bushing 1 K5 Process head 1 K6 Gasket (PTFE), process head 1 K11 Gasket (PTFE), optional flange adapter 1 6/05 ST 3000 HART Transmitter Release 300 User Manual 125 12— Parts List - Replacement Parts Key No. Description Part Number Quantity Per Unit Process Head Kits (one head with Viton head gasket) 30753908-101 Process head assembly kit (Hastelloy C head) 30753908-102 Process head assembly kit (Hastelloy C DIN head) 30753908-103 Process head assembly kit (carbon steel head with side vent/drain) 30753908-104 Process head assembly kit (st. steel head with side vent/drain) 30753908-105 Process head assembly kit (Monel head) 30753908-109 Process head assembly kit (carbon steel head without side vent/drain) 30753908-110 Process head assembly kit (stainless steel head without side vent/drain) 30753908-111 Process head assembly kit (stainless steel DIN head without side vent/drain) 30753908-112 Process head assembly kit (carbon steel head - model STD110 only) 30753908-113 Process head assembly kit (st. steel head - model STD110 only) 30753908-114 Process head assembly kit (carbon steel DIN head - model STD110 only) 30753908-115 Process head assembly kit (st. steel DIN head - model STD110 only) K1 Pipe plug 2 K2 Vent plug 1 K3 Vent bushing 1 K6 Gasket (Viton), process head 1 K11 Gasket (PTFE), flange adapter 1 K5 Process head 1 K1 K2 K3 K3 K2 K1 1 Figure 45 Series 900 DP Meter Body for Models STD924 & STD930 A, B, E, F, and J 6/05 ST 3000 HART Transmitter Release 300 User Manual 126 12— Parts List - Replacement Parts Table 56 Parts Identification for Callouts in Figure 45. Key No. Part Number Description Quantity Per Unit 1 Specify complete model number from nameplate. Series 900 replacement meter body without heads 1 K1 30757506-001 Head bolts carbon steel Kit includes: Bolts, Nuts 4 30757507-001 Head bolts stainless steel/NACE Kit includes: Bolts, Nuts 4 30757507-002 Process Head Bolting 3/8 UNC 316 SS Non-NACE Kit Includes: Process Head Bolts and Nuts 4 30757147-001† Replacement heads carbon steel Kit includes: Heads with side vents, Head gaskets Teflon, head gaskets Viton, Plugs, Bushings, Vent plugs, Gaskets 30757147-002 Replacement heads carbon steel Kit includes: Heads without side vents, Head gaskets Teflon, head gaskets Viton, Bushings, Vent plugs, Gaskets 30757148-001 Replacement heads stainless steel Kit includes: Heads with side vents, Head gaskets Teflon, Head gaskets Viton, Plugs, Bushings, Vent Plugs, Gaskets 30757148-002 Replacement heads stainless steel Kit includes: Heads without side vents, Head gaskets Teflon, Head gaskets Viton, Bushings, Vent Plugs, Gaskets 30757149-001 Replacement heads Hastelloy Kit includes: Heads with side vents, Head gaskets Teflon, Head gaskets Viton, Plugs, Bushings, Vent plugs, Gaskets 30757500-001 Replacement heads Monel Kit includes: Head with side vents, Head gasket Teflon, Head gasket Viton, Plugs, Bushings, Vent plugs, Gaskets 30757505-001† Process Head Gasket Kit Kit includes: 6 Teflon head gaskets (30757100-001), 6 Viton head gaskets (30749274-004), and 6 Teflon flange adapter gaskets (30679622-501) K2 K3 Optional Flange Adapter and Flange Adapter Gaskets - Not Shown 30679622-501 Flange adapter gaskets Teflon 6 6 30749274-502 Flange adapter gaskets Viton 30754419-002 Flange adapter kit (st. steel flange adapters with carbon steel bolts) 30754419-018 Flange adapter kit (st. steel flange adapters with 316 st. steel NACE bolts) K9 Not Shown Bolt, hex head, 7/16-20 UNF, 1.375 inches lg., flange adapter 4 K11 Not Shown Gasket, flange adapter 2 K10 Not Shown Flange adapter 2 K12 Not Shown Filter screen 2 30754419-003 Flange adapter kit (Hastelloy C flange adapters with carbon steel bolts) 30754419-019 Flange adapter kit (Hastelloy C flange adapters with 316 st. steel NACE bolts) Not Shown Bolt, hex head, 7/16-20 UNF, 1.375 inches lg., optional flange adapter 4 K9 K11 Not Shown Gasket, flange adapter 2 K10 Not Shown Flange adapter 2 6/05 ST 3000 HART Transmitter Release 300 User Manual 127 12— Parts List - Replacement Parts K2 K4 2 1 K3 K1 Figure 46 Series 100 GP and AP Meter Bodies and Series 900 AP Meter Body Table 57 Parts Identification for Callouts in Figure 46. Key No. 2 1 Part Number See Table 58 Description Quantity Per Unit Process head (GP/AP models) 1 Specify complete model number from nameplate plus R300 Series 100 replacement meter body without head (GP/AP Models) 1 Specify complete model number from nameplate plus R300 Series 900 replacement meter body without head (GP/AP Models) 1 30754154002† Head gasket kit for all models with narrow profile meter body except STG180 (3 sets) 30754154003† Head gasket kit for model STG180 with narrow profile meter body (3 sets) K2 O-ring 3 K3 Gasket, Teflon [for gasket only - 30756445-502 (narrow profile L.P), or 30756445-503 (STG180) 6 Gasket, Viton [for gasket only - 30756445-504 (narrow profile L.P), or 30756445-505 (STG180) 6 6/05 ST 3000 HART Transmitter Release 300 User Manual 128 12— Parts List - Replacement Parts Key No. Part Number Description 30753792-001 Quantity Per Unit Bolts & nuts kit, all models - narrow profile (carbon steel) K1 Nut, hex, metric, M8 carbon steel 4 K4 Bolt, hex head, metric, M8, 50 mm long 4 30753793-002 A286 SS (NACE) Bolts & 304 SS (NACE) nuts kit, all models - narrow profile K1 Nut, hex, 5/16 (304 stainless steel) 4 K4 Bolt, hex head, 5/16-18 4 30753793-003 Process Head Bolting 316 SS Non-NACE Kit Includes: Process Head Bolts and Nuts. Contains: K1 5/16 –18 UNC 316 SS Non-NACE Heavy Hex Nuts 4 K4 5/16 –18 UNC 316 SS Non-NACE Hex Cap Screw 4 Table 58 Replacement GP and AP Process Head Part Numbers for Narrow Profile Meter Body Material 6/05 Fitting Size Models: STA122, STA140, STG140, STG170, STG180, STA922, STA940 Carbon steel (Series 100) 9/16 - 18UNF-2B 30755124-001 Stainless steel (Series 100) 9/16 - 18UNF-2B 30755124-002 Carbon steel 1/2 in NPT 30755124-005 Stainless steel 1/2 in NPT 30755124-006 Monel 1/2 in NPT 30755124-008 Hastelloy C 1/2 in NPT 30755124-007 ST 3000 HART Transmitter Release 300 User Manual 129 12— Parts List - Replacement Parts K1 K2 K3 K2 K1 1 Figure 47 Series 900 Dual-Head GP Meter Bodies. Table 59 Parts Identification for Callouts in Figure 47. Key No. Part Number Description Quantity Per Unit 1 Specify complete model number from nameplate plus R300 Series 900 replacement meter body without heads (GP models) 1 K1 30757506-001 Head bolts carbon steel, 3/8-inch Kit includes: Bolts, Nuts 4 30757507-001 Head bolts stainless steel/NACE, 3/8-inch Kit includes: Bolts, Nuts 4 30757507-002 Process Head Bolting 3/8 UNC 316 SS Non-NACE Kit Includes: Process Head Bolts and Nuts 4 30757501-001 Replacement heads carbon steel Kit includes: Head with side vents, Head dummy CS, Head gaskets Teflon, Head gaskets Viton, Plugs, Bushings, Vent Plug, Gasket 30757501-002 Replacement heads carbon steel Kit includes: Head without side vents, Head dummy CS, Head gaskets Teflon, Head gaskets Viton, Bushings, Vent Plug, Gasket 30757502-001 Replacement heads stainless steel Kit includes: Heads with side vents, Head dummy SS, Head gaskets Teflon, head gaskets Viton, Plugs, Bushings, Vent plugs, Gaskets 30757502-002 Replacement heads stainless steel Kit includes: Heads without side vents, Head dummy SS, Head gaskets Teflon, head gaskets Viton, Bushings, Vent plugs, Gaskets 30756941-005 Stainless steel blind reference head (HR option) K2 6/05 ST 3000 HART Transmitter Release 300 User Manual 130 12— Parts List - Replacement Parts Key No. K3 Description Part Number 30757505-001† Quantity Per Unit Process head gasket kit Kit includes: 6 Teflon head gaskets (30757100-001), 6 Teflon flange adapter gaskets (30679622-001), 6 Viton head gaskets (30749274-004) Optional Flange Adapter - Not Shown K4 30679622-501 Flange adapter gaskets Teflon 6 30749274-502 Flange adapter gaskets Viton 6 Hexagonal Body Round Body Figure 48 Series 100 and Series 900 LGP/LAP Meter Body. Table 60 Parts Identification for Callouts in Figure 48. Key No. 1 6/05 Part Number Description Quantity Per Unit Specify complete model number from nameplate plus R300 Series 100 replacement meter body (LGP model) 1 Specify complete model number from nameplate plus R300 Series 900 replacement meter body (LGP model) 1 ST 3000 HART Transmitter Release 300 User Manual 131 12— Parts List - Replacement Parts Figure 49 Series 900 Flush Mount Meter Body. Table 61 Parts Identification for Callouts in Figure 49. Key No. 1 6/05 Description Part Number Specify complete model number from nameplate plus R300 Series 900 replacement meter body (Flush Mount model) 30756445-508 Gasket Kit (0-rings) 51204496-001 316L SS Mounting Sleeve Kit 51204497-001 Calibration Sleeve Kit ST 3000 HART Transmitter Release 300 User Manual Quantity Per Unit 1 132 12— Parts List - Replacement Parts 1 Extended Flange Design Pseudo Flange Design Figure 50 Series 100 and Series 900 Flange Mounted Meter Body. 6/05 ST 3000 HART Transmitter Release 300 User Manual 133 12— Parts List - Replacement Parts Table 62 Parts Identification for Callouts in Figure 50. Key No. 1 Description Part Number Quantity Per Unit Specify complete model number from nameplate plus R300 Series 100 replacement meter body 1 Specify complete model number from nameplate plus R300 Series 900 replacement meter body 1 30749372-005 O-ring seal 1 30749372-001 O-ring seal 1 Optional Flange Adapter - Not Shown 30754419-006 Flange adapter kit (st. steel flange adapter with carbon steel bolts) 30754419-008 Flange adapter kit (Monel flange adapter with carbon steel bolts) 30754419-022 Flange adapter kit (st. steel flange adapter with 316 st. steel bolts) 30754419-024 Flange adapter kit (Monel flange adapter with 316 st. steel bolts) K1 Bolt, hex head, 7/16-20 UNF, 1.375 inches lg. 2 K2 Flange adapter 1 K3 Gasket 1 K4 Filter screen 1 30754419-007 Flange adapter kit (Hastelloy C flange adapter with carbon steel bolts) 30754419-023 Flange adapter kit (Hastelloy C flange adapter with 316 st. steel bolts) K1 Bolt, hex head, 7/16-20 UNF, 1.375 inches lg. 2 K2 Flange adapter 1 K3 Gasket 1 Housing seal kit 1 K5 6/05 30757503-001 ST 3000 HART Transmitter Release 300 User Manual 134 12— Parts List - Replacement Parts 1 1 Sanitary Seal Small Flange NPT Figure 51 High Temperature Meter Body. Table 63 Parts Identification for Callouts in Figure 51. Key No. 1 Part Number Specify complete model number from nameplate plus R300 Description Series 100 replacement meter body Quantity Per Unit 1 Sanitary Seal Head and Gasket 51204982-001 Sanitary Seal Head GP/I (Stainless Steel Head w/ st.stl. hardware) 51204982-003 Sanitary Seal Head GP/I (Stainless Steel Head w/ SS NACE. hardware) 51204982-002 Sanitary Seal Head GP/I (Hastelloy Head w/ st.stl. hardware) 51204984-001 Gasket GP/I (includes Teflon gasket and Viton O-ring) Flange Adapter - Not Shown 6/05 51204983-001 Flange adapter kit (½” NPT st. stl. 150# w/ st. stl bolts) 51204983-002 Flange adapter kit (½” NPT st. stl. 150# w/ st. stl bolts w/ vent/drain) 51204983-017 Flange adapter kit (½” NPT st. stl. 150# w/ SS NACE bolts) 51204983-018 Flange adapter kit (½” NPT st. stl. 150# w/ SS NACE bolts w/ vent/drain) 51204983-003 Flange adapter kit (½” NPT Hastelloy 150# w/ st. stl bolts) 51204983-004 Flange adapter kit (½” NPT Hastelloy 150# w/ st. stl bolts w/ vent/drain) 51204983-005 Flange adapter kit (1” NPT st. stl. 150# w/ st. stl bolts) 51204983-006 Flange adapter kit (1” NPT st. stl. 150# w/ st. stl bolts w/ vent/drain) 51204983-019 Flange adapter kit (1” NPT st. stl. 150# w/ SS NACE bolts) 51204983-020 Flange adapter kit (1” NPT st. stl. 150# w/ SS NACE bolts w/ vent/drain) 51204983-007 Flange adapter kit (1” NPT Hastelloy 150# w/ st. stl bolts) ST 3000 HART Transmitter Release 300 User Manual 135 12— Parts List - Replacement Parts Key No. 6/05 Part Number Description 51204983-008 Flange adapter kit (1” NPT Hastelloy 150# w/ st. stl bolts w/ vent/drain) 51204983-013 Flange adapter kit (1” NPT st. stl. 300# w/ st. stl bolts) 51204983-014 Flange adapter kit (1” NPT st. stl. 300# w/ st. stl bolts w/ vent/drain) 51204983-023 Flange adapter kit (1” NPT st. stl. 300# w/ SS NACE bolts) 51204983-024 Flange adapter kit (1” NPT st. stl. 300# w/ SS NACE bolts w/ vent/drain) 51204983-015 Flange adapter kit (1” NPT Hastelloy 300# w/ st. stl bolts) 51204983-016 Flange adapter kit (1” NPT Hastelloy 300# w/ st. stl bolts w/ vent/drain) 51204983-009 Flange adapter kit (1½” NPT st. stl. 150# w/ st. stl bolts) 51204983-010 Flange adapter kit (1½” NPT st. stl. 150# w/ st. stl bolts w/ vent/drain) 51204983-021 Flange adapter kit (1½” NPT st. stl. 150# w/ SS NACE bolts) 51204983-022 Flange adapter kit (1½” NPT st. stl. 150# w/ SS NACE bolts w/ vent/drain) 51204983-011 Flange adapter kit (1½” NPT Hastelloy 150# w/ st. stl bolts) 51204983-012 Flange adapter kit (1½” NPT Hastelloy 150# w/ st. stl bolts w/ vent/drain) 51204983-025 Flange adapter kit (2” st. stl. 150# w/ st. stl bolts) 51204983-026 Flange adapter kit (2” st. stl. 150# w/ st. stl bolts w/ vent/drain) 51204983-037 Flange adapter kit (2” st. stl. 150# w/ SS NACE bolts) 51204983-038 Flange adapter kit (2” st. stl. 150# w/ SS NACE bolts w/ vent/drain) 51204983-027 Flange adapter kit (2” Hastelloy 150# w/ st. stl bolts) 51204983-028 Flange adapter kit (2” Hastelloy 150# w/ st. stl bolts w/ vent/drain) 51204983-029 Flange adapter kit (1½” st. stl. 300# w/ st. stl bolts) 51204983-030 Flange adapter kit (1½” st. stl. 300# w/ st. stl bolts w/ vent/drain) 51204983-039 Flange adapter kit (1½” st. stl. 300# w/ SS NACE bolts) 51204983-040 Flange adapter kit (1½” st. stl. 300# w/ SS NACE bolts w/ vent/drain) 51204983-031 Flange adapter kit (1½” Hastelloy 300# w/ st. stl bolts) 51204983-032 Flange adapter kit (1½” Hastelloy 300# w/ st. stl bolts w/ vent/drain) 51204983-033 Flange adapter kit (2” st. stl. 300# w/ st. stl bolts) 51204983-034 Flange adapter kit (2” st. stl. 300# w/ st. stl bolts w/ vent/drain) 51204983-041 Flange adapter kit (2” st. stl. 300# w/ SS NACE bolts) 51204983-042 Flange adapter kit (2” st. stl. 300# w/ SS NACE bolts w/ vent/drain) 51204983-035 Flange adapter kit (2” Hastelloy 300# w/ st. stl bolts) 51204983-036 Flange adapter kit (2” Hastelloy 300# w/ st. stl bolts w/ vent/drain) ST 3000 HART Transmitter Release 300 User Manual Quantity Per Unit 136 12— Parts List - Replacement Parts Table 64 Summary of Recommended Spare Parts. Reference Part Number Description Figure Nmbr. Key Nmbr. Spares for 1-10 Units 10100 Units 1001000 Units Electronics Housing Assembly Figs 42 and 43 51309397-502 Electronics Module Assembly 42 5 1 1-2 2-4 30757503-001 Series 100/900 housing seal kit 42, 43 K1 1 1-2 2-4 51205897-501 Series 100/900 terminal assembly without lightning protection 43 3/K2 1 1 1-2 51404078-502 Series 100/900 terminal assembly with lightning protection 1 1-4 4-10 1 1-2 2-4 Process head gasket kit 45, 47 K3 30757505-001 For STD924-A, B, E, F, and J; STD930-A, B, E, F, and J; STG944; STG974 models Teflon and Viton 44 K7 30753788-003 30753788-004 For all other Series 100 DP and STD924-C, D, G, H, K, and L; STD930-C, D, G, H, K, and L; and STD974 models Teflon Viton 46 K1 30754154-002 For STA122, STA140, STA922, STA940, STG140, and STG170 Teflon and Viton 30754154-003 For STG180 46 K3 Meter Body Specify Series 100/900 DP Models 44 1 complete model Series 900 DP Models 44, 45 1 number from Series 100/900 GP/AP Models 46 1 nameplate plus Series 900 GP Dual Head Model 47 1 R300 Series 100/900 LGP/LAP and Series 900 AP Models 48 1 Series 900 Flush Mount Models 49 1 Series 100/900 Flange Mount Models 50 1 Series 100 High Temperature Models 51 1 6/05 ST 3000 HART Transmitter Release 300 User Manual 137 13— Reference Drawings - Wiring Diagrams 13— Reference Drawings Wiring Diagrams Contents These wiring diagrams are included in numerical order behind this section for wiring reference. External Wiring Diagrams ST 3000 HART Description Drawing number Release 300 For intrinsically safe application (FM) 51205784 Series 100, 900 For intrinsically safe application (CENELEC) 51204215 Transmitters For intrinsically safe application (CSA) 51450806 Dimension Drawings Dimension drawings for individual transmitter models are available and are listed in this manual. If you need a copy of a drawing, please determine the appropriate drawing number and contact your Honeywell representative to obtain a copy. 6/05 ST 3000 HART Transmitter Release 300 User Manual 137 13— Reference Drawings - Wiring Diagrams 6/05 ST 3000 HART Transmitter Release 300 User Manual 138 Appendix A— Smart Meter Reference - Introduction Appendix A— Smart Meter Reference Introduction About this section This section describes the integral smart meter options available with the ST 3000 Release 300 HART transmitter. Procedures are given for setting range values of the transmitter using the smart meter pushbuttons. You can use the meter pushbuttons or the HART communicator to set up the smart meter display to indicate transmitter PV output. Typical smart meter indications are given as well as examples and descriptions of possible error codes displayed on the smart meter. 6/05 ST 3000 HART Transmitter Release 300 User Manual 139 Appendix A— Smart Meter Reference - Introduction Smart meter option Depending upon your transmitter model, you can equip the ST 3000 transmitter with the Smart Meter option (option SM). This new integral smart meter is designed for ST 3000 Release 300 Transmitters and provides functionality not available with other smart meter designs. The smart meter provides an LCD local interface that displays both analog and digital indications of the transmitter output and can be configured to display pressure in user-selected engineering units. There are three meter option types: Meter option Description VAR SEL. SPAN UPPER VALUE 0 % 100 Smart Meter with local Zero and Span Adjustments – Features smart meter LCD interface, pushbuttons for setting engineering units and lower range/upper range values, and zero/span adjustments. UNITS SET ZERO LOWER VALUE Local Zero and Span Adjustments only – Provides pushbuttons to make zero and span adjustments. SPAN ZERO Smart Meter only – Features smart meter LCD interface, pushbuttons for setting engineering units and lower range/upper range values. VAR SEL. UPPER VALUE 0 % 100 UNITS SET LOWER VALUE Note: The Model STD110 does not support local zero and span adjustments. Smart Meter Set up The smart meter can be set up to display pressure in a number of user-selected engineering units or even custom units, if required. The meter display set up is part of the transmitter configuration database and can be performed when configuring the transmitter. You can use either the HART communicator or the pushbuttons on the front of the meter to set up the smart meter display. The procedures for either method of meter set up are provided in this appendix. 6/05 ST 3000 HART Transmitter Release 300 User Manual 140 Appendix A— Smart Meter Reference - Smart Meter Display Smart Meter Display Display description Figure A-1 shows a smart meter display with all its indicators and segments lit for reference. Descriptions of the meter indicators are listed in Table A-1. Table A-2 shows the smart meter with the pushbuttons highlighted and a brief description of each pushbutton. The pushbuttons are used for setting up the smart meter display and making zero and span adjustments. 17-Segment Bargraph (0 to 100%) VAR SEL. UPPER VALUE 0 SPAN Digital Readout (-19990 to +19990) ZERO % 100 -18 8. 80 OUTPUT MODE CHECK STATUS KNOWN VALUE ANALOG K oF oC % FLOW UNITS SET In H O 2 LOWER GPH mmHg VALUE GPM PSI A Status Indicators Engineering Unit Indicators K Multiplier Indicates digital readout is multiplied by 1,000 Figure A-1 Smart Meter Display with All Indicators Lit. Table A-1 Description of Smart Meter Display Indicators Display Indicator What It Means When Lit 17-Segment Bargraph Gives a gross indication of the transmitter’s PV output from 0 to 100%. Digital Readout Gives an indication of the transmitter’s PV output in either percent of span or actual engineering units. The display range is ±19,990,000 and it is automatically ranged to provide the best precision possible within the limits of the display. A second decimal place expands the precision of range values within ±19.99 to 1/100th of a unit. % Digital readout represents output in percent of span. This is the default engineering units selection. FLOW Transmitter is configured for square root output conformity. OUTPUT MODE Transmitter is in its output mode and it is not sending a real PV signal. CHECK STATUS Transmitter in multidrop mode and showing a critical status or if transmitter is in Analog mode, the transmitter has an output that is less than –2.0% or greater than 106%. Use the communicator to check transmitter’s status. 6/05 ST 3000 HART Transmitter Release 300 User Manual 141 Appendix A— Smart Meter Reference - Display Indicator What It Means When Lit KNOWN VALUE The upper value or lower value being displayed has previously been configured to the value shown. ANALOG Transmitter is in its analog mode. (When indicator is OFF, transmitter is in multidrop mode) K Multiplies digital reading by 1,000. Turns on automatically when reading exceeds 1999. A Transmitter is absolute pressure type. Digital readout represents absolute values. Engineering Units Indicators Inches of Water Gallons per hour Gallons per minute Millimeters of Mercury Pounds per Square Inch inH2O GPH GPM MmHg PSI Selectable engineering units - Available as a stick-on label from Honeywell drawing number 30756918-001. Additional Engineering Units (stick-on label not shown) Kpa Mpa mbar bar g/cm2 Kg/cm2 mmH2O inHg mH2O = = = = = = = = = Kilopascals Megapascals Millibar Bar Grams per Square Centimeter Kilograms per Square Centimeter Millimeters of Water Inches of Mercury Meters of Water Table A-2 Smart Pushbutton Description Smart Meter Pushbuttons VAR SEL. SPAN ZERO Pushbutton UPPER VALUE -18 8. 8 0 OUTPUT MODE CHECK STATUS KNOWN VALUE ANALOG K oF oC % FLOW VAR SEL. Not functional when installed with ST 3000 transmitters. SPAN Selects Span range setting (URV). ZERO Selects Zero range setting. UPPER VALUE Selects upper display limit for custom or flow engineering units. UNITS SET Selects engineering units for meter display. LOWER VALUE Selects Lower display limit for custom or flow engineering units. UNITS SET In H O LOWER 2 VALUE GPH mmHg GPM PSI A Function Decrease pushbutton Increase pushbutton 6/05 ST 3000 HART Transmitter Release 300 User Manual 142 Appendix A— Smart Meter Reference - Smart Meter Specifications Smart Meter Specifications Operating conditions and specifications Before installing a transmitter equipped with a smart meter or installing the smart meter in an existing transmitter, please note the specifications and operating limits of the meter in Table A-3. Table A-3 Smart meter specifications. Operating Conditions Parameter Rated Ambient Temperature Relative Humidity °F °C %RH Extreme, Transportation and Storage –40 to 176 –40 to 80 –58 to 194 –50 to 90 10 to 90 0 to 100 Design No error. Reproduces transmitter signal exactly within its resolution. Accuracy Display Resolution Bargraph Digital Readout Display Update Rate ±3% of reading ±0.005 for ±19.99 reading range, ±0.05 for ±199.9 reading range, ±0.5 for ±1999 reading range, ±5 for ±19990 reading range, ±50 for ±199900 reading range, ±500 for ±1999000 reading range, ±5000 for ±19990000 reading range. Shown as: 19.99 199.9 1999 19.99 K 199.9 K 1999 K 19990 K Above 32°F (0°C): ½ second @ or below 32°F (0°C): 1½ seconds Meter Display at High and Low Temperature Extremes The rated temperature limits for the local meter are listed above and are true in that no damage to the meter will occur over these temperatures, however the readability of the LCD is affected if taken to these temperature extremes: • The LCD will turn black at some temperature between 80 to 90 °C (176 and 194 °F), rendering the display unreadable. This effect is only temporary, and normally occurs at 90 °C (194 °F). • At low temperatures, the update rate of the display is lengthened to 1.5 seconds due to the slower response time of the display. At -20 °C (-4 °F) the display becomes unreadable due to slow response of the LCD. This is also only temporary and normal readability will return when temperature returns above -20 °C (-4 °F). 6/05 ST 3000 HART Transmitter Release 300 User Manual 143 Appendix A— Smart Meter Reference - Setting Range Values (Local Zero and Span) Setting Range Values (Local Zero and Span) Local zero and span option ST 3000 Release 300 transmitters are available with optional local zero and span adjustments. This option is for applications that do not require a HART communicator nor digital integration with our TPS system. About local adjustments You must apply equivalent zero and span pressures to make the local zero and span adjustments. This is similar to LRV correct and URV set using the HART communicator. We recommend that you calibrate the transmitter before setting up the meter for custom engineering units. The procedure in Table A-4 shows the steps for setting the range values to applied pressures using local zero and span adjustments. See Figure A-2 for typical local adjustment setup details. ATTENTION All procedures in this manual assume a transmitter poll address of 0 (zero). See Section 6, for information about poll address. After making any adjustments to the smart meter, keep the transmitter powered for at least 30 seconds so that the new meter configuration is written to non-volatile memory. If power is turned off before 30 seconds, the changes may not be saved so that when the transmitter power is restored, the meter configuration will revert to the previous settings. Table A-4 Setting Range Values Using Local Zero and Span Adjustments Step Action 1 Turn OFF transmitter power. Loosen end-cap lock and remove end-cap from terminal block side of electronics housing. 2 Observing polarity, connect a milliammeter across positive (+) and negative (–) TEST terminals. ATTENTION If you have the smart meter with local zero and span adjustment option, you may use the smart meter in place of the milliammeter. 3 Loosen end-cap lock and remove end-cap from PWA side of electronics housing to expose local zero and span assembly or smart meter with zero and span adjustments. Examples – Local zero and span assembly, and Smart meter with zero and span adjustments. VAR SEL. UPPE R VALUE 0 SP AN SP AN % 100 UNITS SE T ZERO ZERO LOWER VALUE and 6/05 ST 3000 HART Transmitter Release 300 User Manual 144 Appendix A— Smart Meter Reference - Setting Range Values (Local Zero and Span) Step 4 Action Turn ON transmitter power and let it warm up for a few minutes. Using an accurate pressure source, apply desired zero equivalent pressure to transmitter. ATTENTION For differential pressure transmitters, apply pressure to the high pressure head for positive range values or vent both heads to atmosphere for zero. If zero is to equal a negative value, apply the equivalent pressure to the low pressure head. For example, if zero is to equal –10 inH2O, you would apply 10 inH2O to the low pressure head and vent the high pressure head for the zero adjustment. 5 Check that milliammeter reading is 4 mA. • If reading is less or greater than 4 mA, Then go to Step 6. • If reading is correct, go to Step 7. ATTENTION If you have the smart meter with local zero and span adjustment option, you may substitute the smart meter readings for the milliammeter readings. For example, with zero input pressure applied assume that the meter reads 4 inH2O instead of 0 inH2O. In this case, the meter reading is greater than 0 (or 4 mA). 6 d) Press and hold ZERO button on local zero and span assembly or smart meter. ATTENTION The smart meter readings revert to the default unit of percent (%) during this operation. If the error code Er0 appears on the display, you are working with a model STD110 transmitter that does not support the local zero and span adjustments. e) Press Decrease button once to complete this function. The smart meter display goes blank for a 1/2 second and then returns reading 0%. f) Check that milliammeter reading equals 4 mA and release ZERO button. ATTENTION If milliammeter reading doesn’t change, be sure you are not working with a model STD110 transmitter that ignores local adjustments. The smart meter readings return to the set engineering units after you release the ZERO button. If zero correction is + or – 5% of upper range limit, the CHECK STATUS indicator will be displayed. If range setting is intentional, disregard status message. 7 Using an accurate pressure source, apply pressure equivalent to desired upper range value to transmitter. ATTENTION For differential pressure transmitters, apply pressure to the high pressure head and be sure that the low pressure side is vented to atmosphere. If the applied pressure produces an output of greater than 200%, the meter display will flash O-L and the 200% value during this interim step. 6/05 ST 3000 HART Transmitter Release 300 User Manual 145 Appendix A— Smart Meter Reference - Setting Range Values (Local Zero and Span) Step 8 Action Check that milliammeter reading is 20 mA. • If reading is not exactly 20 mA, Then go to Step 9. • If reading is correct, go to Step 10. ATTENTION If you have the smart meter with local zero and span adjustment option, you may substitute the smart meter readings for the milliammeter readings. For example, with URV input pressure applied, assume that the meter reads 396 inH2O instead of 400 inH2O. In this case, the meter reading is less than 100% (or 20 mA). 9 a) Press and hold SPAN button on local zero and span assembly or smart meter. ATTENTION The smart meter readings revert to the default unit of percent (%) during this operation. If the error code Er0 appears on the display, you are working with a model STD110 transmitter that does not support the local zero and span adjustments. b) Press Increase button once to complete this function. ATTENTION If the error code Er4 appears, you are trying to set a SPAN value that is outside acceptable limits for your transmitter. Readjust applied pressure to be within acceptable range limits and repeat this procedure. The smart meter display goes blank for a 1/2 second and then returns reading 100%. c) Check that milliammeter reading equals 20 mA and release SPAN button. ATTENTION If milliammeter reading doesn’t change, be sure you are not working with a model STD110 transmitter that ignores local adjustments. The smart meter readings return to the set engineering units after you release the SPAN button. 6/05 10 Wait 30 seconds so that changes are copied to the transmitter’s non-volatile memory. 11 Remove applied pressure and turn OFF transmitter power. 12 Replace end-cap on PWA side of electronics housing and tighten lock. 13 Remove milliammeter from TEST terminals and replace end-cap and tighten lock. 14 Turn ON transmitter power and check smart meter reading, if applicable. ST 3000 HART Transmitter Release 300 User Manual 146 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons ST 3000 + - SIGNAL + Power Supply - + Receiver 250 ohm + TEST - Field Terminals VAR SEL. UPPER VALUE 0 SPAN Smart Meter with Local Zero and Span installed on PWA side of electronics housing % 000 AN ALOG ZERO 100 UNITS SET In H 2 O LOWER VALUE Milliammeter Figure A-2 Typical Setup for Setting Range Values Using Local Zero and Span Adjustments. Configuring Smart Meter Using Pushbuttons The smart meter can be set to show the PV output in engineering units that are appropriate for your process application. You can select an available engineering unit or enter a custom one including upper and lower display limits settings for the smart meter’s digital readout using buttons on the face of the meter. Using the Smart Meter Follow these guidelines when configuring the smart meter: If you initiate a command with the HART communicator at the same time a button is pressed on the smart meter, the smart meter will respond to the command it receives last. In other words, the last command wins. In most cases, you can press and release a button for one-shot operation, or press and hold a button for continuous, 1/2 second, repetitive operation. Active setup field will begin to flash at one second rate if next action is not initiated within one second. And, if no action is taken within 30 seconds, the setup function will time out and the meter will return to its previous state. 6/05 ST 3000 HART Transmitter Release 300 User Manual 147 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons Transmitter Output Conformity and Smart Meter Configuration Normally when using a differential type transmitter, you can select the transmitter’s output to represent a straight linear calculation or a square root calculation for flow measurement applications. This linear or square root output parameter selection is called output conformity or output form. (See Section 6 for more details on output conformity.) When configuring the smart meter to display the transmitter output measurement, there are certain rules to keep in mind which are dependent on the output conformity selection. These rules are described in the following paragraphs. The output conformity setting of the transmitter restricts the engineering units you can select for the smart meter display. When the transmitter is configured for an output conformity of LINEAR, you can select only pressure type engineering units. (See Table A-5.) When the transmitter is configured for an output conformity of SQUARE ROOT, you can select only flow type engineering units GPM and GPH. The percent and custom engineering units can be selected regardless of output conformity configuration. Table A-5 Smart Meter Engineering Units Code Smart Meter Code * † 6/05 Engineering Unit Transmitter Output Conformity EU0 % * Linear or Square Root EU1 in H2O * EU2 mmHg * EU3 PSI * EU4 kPa † EU5 MPa † EU6 mbar † EU7 bar † EU8 g/cm2 † EU9 kg/cm2 † EUA mmH2O † EUB inHg † EUC mH2O † EUD GPM * Square Root EUE GPH * Square Root EUF Custom † Linear or Square Root Linear These selections have indicators on smart meter display. Use stick-on labels provided for other engineering units. ST 3000 HART Transmitter Release 300 User Manual 148 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons Additionally, the output conformity setting restricts the setting of the lower and upper display limits to represent transmitter’s 0 to 100% output. If you select pressure type engineering units, you cannot set the lower or upper display limits. These values are automatically set when you select the engineering units. You can set only the upper display limit when the transmitter is configured for SQUARE ROOT output conformity. The lower display limit is fixed at zero (0) for a transmitter in square root mode and cannot be changed. You can set both the lower and upper display limits when you have selected custom engineering units (EUF) and the transmitter output conformity is set to LINEAR. When setting the lower and upper display limits, if you let either the lower or upper display limit setting time out (after thirty seconds), the meter will discard the newly set values and will revert to its previous settings. The meter forces you to set both limits by automatically initiating the next limit setting, either lower or upper, depending upon which limit you set first. If you change the transmitter’s output conformity, you must reconfigure the smart meter as outlined in Tables A-6, A-7 and A-8 or Table A-9. See also “Meter/transmitter interaction” in this appendix. Selecting Engineering Units The procedure in Table A-6 outlines the steps for selecting the desired engineering units for a smart meter using its local adjustments on the face of the meter. You will be selecting the unit of measurement that you want the smart meter to indicate during normal operation. WARNING When the transmitter’s end-cap is removed, the housing is not explosionproof. Table A-6 Selecting Engineering Units Step Action 1 Loosen lock on meter end-cap and unscrew cap from housing. Be sure transmitter power is ON. 2 Press UNITS SET button. Result Display shows code for current engineering units setting. VAR UPPE R SEL. VALUE 0 % EU 0 ANALOG 6/05 ST 3000 HART Transmitter Release 300 User Manual 100 UNITS % SET LOWER VALUE 149 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons Step Action 3 Press Increase key to call up next code or Decrease key to call up previous code. Repeat this action until desired code is on display. Result Selection codes for engineering units You can hold down the Increase or Decrease key to scroll forward or backward through the codes. VA R SEL. UPPE R VALUE % 0 ATTENTION Remember that if transmitter is configured for SQUARE ROOT output conformity the only valid code selections are: EU0 (%) EUD (GPM) EUE (GPH) EUF (Custom) 100 EU 1 UNIT S SE T ANALOG Press and hold to scroll backward through selections In H 2 O LOWER VALUE Press and hold to scroll forward through selections EU0 = %* EU1 = inH2O* If transmitter is configured for LINEAR output conformity EU0 (%) to EUC and EUF (CUSTOM) are valid code selections. EU2 = mmHg* EU3 = PSI* EU4 = KPa EU5 = MPa EU6 = mbar EU7 = bar EU8 = g/cm2 EU9 = Kg/cm2 EUA = mmH2O EUB = inHg EUC = mH2O *These selections have indicators on the display. EUD = GPM* EUE = GPH* EUF = Custom 4 Press UNITS SET button to lock in selected code. ATTENTION VAR SEL. If you select an invalid code according to the selections in Step 3, the meter display will show an error code Er1 for one second and then return to the previous engineering units selection. UPPE R VALUE 0 % 0. 1 8 ANALOG 100 UNITS SET In H 2 O LOWER VALU E Goes blank for 1/2 second and returns with reading in engineering units 5 If selected engineering unit does not match one of six unit indicators on meter, peel off matching stick-on unit label from sheet (drawing number 30756918-001) and paste it in lower right hand corner of meter. Digital reading now in engineering units of inches of water Use stick-on label for engineering units without indicators on display. VAR SEL. UPPE R VALUE 0 % 100 1. 0 2 UNITS SET ANALOG LOWER VALUE Kg/cm2 Stick-on label identifies selected engineering units 6/05 ST 3000 HART Transmitter Release 300 User Manual 150 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons Step Action Result 6 If you selected Custom or Flow engineering units, go to Tables A-7 and A-8 to set lower and upper display limits for smart meter display. Lower and upper display limits have not been set for custom or flow engineering units. VA R SEL. UPPER VALUE 0 % 100 U- L UNITS SET FLOW ANALOG LOWER VALUE GPM Setting Lower and Upper Display Values The table below shows the restrictions on setting the display values for given engineering units and output conformity selections. Engineering Output Set Units code Conformity Lower Display Value? Upper Display Value? EU0 through EUC Linear No (set automatically) No (set automatically) Square root No (fixed at zero) Yes (Pressure type units) EU0, EUD, EUE,and EUF (%, GPM, GPH, or Custom) EUF (Custom) Use Table A-8 Linear Yes Yes Use Table A-7 Use Table A-8 To set the lower and upper display limit values for the meter display perform the procedures in Tables A-7 and A-8. Also note that in each procedure you must: First set the magnitude range for each display value. This enables the multiplier (K) on the display for indicating larger ranges (greater than 19999 and shifts the decimal point of the digital display left or right depending on the precision you want to show for that value). Next set the display value. This procedure sets the display limit of the meter to represent minimum and maximum transmitter output (0% and 100 % output). Note: Magnitude range and display values are set for both upper and lower (if applicable) display limits. During normal operation the display range of the meter digital readout is ±19,990,000 and is automatically ranged to provide the best precision possible for the digits available up to 1/100th of a unit. ATTENTION Please read through the entire procedure before beginning. 6/05 ST 3000 HART Transmitter Release 300 User Manual 151 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons Setting Lower Display Values The procedure in Table A-7 outlines the steps for setting the lower display limit to represent the 0 percent (LRV) output of the transmitter. ATTENTION For example purposes, the procedures in Tables A-7 and A-8 assume that the lower value is to be set at 0 and the upper value is to be set at 19,990,000 for a CUSTOM unit in a transmitter with a LINEAR output, and the transmitter’s present output is exactly 50 percent. Table A-7 Setting Lower Display Values for Smart Meter Display Step Action 1 You have completed units selection in Table A-6 and U-L appears on the display. Press LOWER VALUE button to initiate lower display limit setting function. Result If lower limit display value was previously set, KNOWN VALUE indicator lights and set value flashes in display. ATTENTION VA R SEL. This procedure is only applicable for Custom (EUF) engineering unit selection in a transmitter configured for LINEAR output conformity. The lower display value for transmitters configured for SQUARE ROOT output conformity is fixed at zero (0.00) and cannot be changed. 2 Press LOWER VALUE button again within 5 seconds to access magnitude range setting. Otherwise, meter exits limit setting function. NOTE: Magnitude range enables the multiplier (K) for indicating larger ranges and shifts the decimal point of the digital display left or right depending on which button is pushed. The display shows largest positive number for given range selection so you can select a range that is just larger than the range to be set for best display precision. UPPER VALUE 0 % 100 0 .0 0 UNITS SE T ANALOG LOWER VALUE KNOWN VALUE Previously set value flashes in display and indicator lights Display shows magnitude range selection. VAR SEL. UPPE R VALUE 0 % 19 .99 ANALOG 100 UNITS SE T LOWER VALUE ATTENTION The magnitude range selection only applies for setting the meter display limits. This selection does not affect the normal operation of the meter. During normal operation, the display is automatically ranged to provide the best precision possible. 6/05 ST 3000 HART Transmitter Release 300 User Manual 152 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons Step Action 3 Press Increase button to shift the decimal point to the right and increase the magnitude range or Decrease button to shift the decimal point to the left and decrease the magnitude range. Repeat this action until desired selection is on display. Result Magnitude range selections. VA R SEL. UPPE R VALUE 0 Also you can hold the respective key to scroll forward or backward through the selections. % 19 .9 9 ANALOG Press and hold to scroll backward through selections 4 Press LOWER VALUE button to initiate lower display value setting. 19.99 199.9 1999 19.99K* 199.9K* 1999K* 19990K* 100 UNITS SET LOWER VALUE Press and hold to scroll forward through selections *The "K" multiplier indicator appears below the digital reading on the display. Readout goes blank except for first active digit which will be 0 unless lower value was set before. VAR UPPE R SEL. VALUE 0 % 0 ANALOG 6/05 ST 3000 HART Transmitter Release 300 User Manual 100 UNITS SET LOWER VALUE 153 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons Step 5 Action Press Increase button to select the next available digit value or Decrease button to select the previous digit value. Repeat this action until desired value is on display. 6 Result First digit value setting. VAR SEL. UPPE R VALUE % 0 Press LOWER VALUE button to lock-in first digit and activate next active digit. Press Increase button to select the next available digit value or Decrease button to select the previous digit value. Press and hold to scroll backward through values 8 Press LOWER VALUE button to lock-in second digit and activate next active digit. Readout now displays next active digit which will be zero unless lower value was set before. 9 Press Increase button to select the next available digit value or Decrease button to select the previous digit value. Repeat this action until desired value is on display. VAR UPPE R SEL. Press LOWER VALUE button to lock-in third digit and activate next active digit. VALUE % 0 .0 0 ANALOG Readout now displays next active digit which will be BLANK unless lower value was set to 1 before. 11 Press Increase button to set digit to 1 or Decrease button to set it to BLANK. 12 Press LOWER VALUE button to lock-in “1” digit and activate sign segment. Press and hold to scroll backward through values Readout now displays sign segment which will be BLANK for positive values unless lower value was set for negative (–) values before. 6/05 Press and hold to scroll forward through values Third digit value setting. 0 10 LOWER VALUE 0 1 2 3 4 5 6 7 8 9 Repeat this action until desired value is on display. UNITS SET ANALOG Readout now displays next active digit which will be zero unless lower value was set before. 7 0 100 ST 3000 HART Transmitter Release 300 User Manual 0 1 2 3 4 5 6 7 8 9 100 UNITS SET LOWER VALUE Press and hold to scroll forward through values 154 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons Step Action 13 Press Increase button to set sign segment to minus sign for negative values or Decrease button to set it to BLANK. for positive values. 14 Press LOWER VALUE button to lock in current settings as lower display value limit. Result Sign segment setting. VAR VALUE 0 ATTENTION For CUSTOM unit in transmitter with LINEAR output, you must set both lower and upper display limits for values to take effect. If you let either the lower or upper display limit time out (after 30 seconds), the meter discards both newly set values and reverts back to the previously set values. UPPE R SEL. % 0 .0 0 ANALOG Press to set sign segment as BLANK for positive values 100 UNITS SET LOWER VALUE Press to set sign segment as minus sign (-) for negative values • If you have not yet set the upper display limit value, the meter automatically enters the upper display setting function after it displays previously set value, if applicable. Go to Table A-8. • If you have already set the upper display limit value, this completes the lower and upper display limits setting function for Custom engineering units in the transmitter. Meter returns to normal operation. Setting Upper Display Values The procedure in Table A-8 outlines the steps for setting the upper display limit to represent the 100 percent (URV) output of the transmitter. ATTENTION This procedure applies only for Flow units (GPM or GPH) in a transmitter configured for SQUARE ROOT output conformity, or CUSTOM unit in a transmitter configured for linear or square root output conformity. Table A-8 Setting Upper Display Value for Smart Meter Display Step 1 6/05 Action Press UPPER VALUE button to initiate upper display limit setting function. Result If upper limit display value was previously set, KNOWN VALUE indicator lights and set value flashes in display. ST 3000 HART Transmitter Release 300 User Manual 155 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons Step 2 Action Press UPPER VALUE button again within 5 seconds to access magnitude range setting. Otherwise, meter exits limit setting function. NOTE: Magnitude range enables the multiplier (K) for indicating larger ranges and shifts the decimal point of the digital display left or right depending on which button is pushed. The display shows largest positive number for given range selection so you can select a range that is just larger than the range to be set for best display precision. Result Display shows magnitude range selection. VAR UPPE R SEL. VALUE 0 % 19 .99 100 UNITS SET ANALOG LOWER VALUE ATTENTION The magnitude range selection only applies for setting the display limits. This selection does not affect the normal operation of the meter. During normal operation, the display is automatically ranged to provide the best precision possible. 3 Press Increase button to shift the decimal point to the right and increase the magnitude range or Decrease button to shift the decimal point to the left and decrease the magnitude range. Repeat this action until desired selection is on display. For example purposes only, largest range 19990K is selected in this procedure. Magnitude range selections with largest range selected. V AR SEL. UPPE R VALUE 0 Also you can hold the respective key to scroll forward or backward through the selections. % 19 9 90 ANALOG K Press and hold to scroll backward through selections 4 Press UPPER VALUE button to initiate upper value setting. 19.99 199.9 1999 19.99K* 199.9K* 1999K* 19990K* 100 UNITS SET LOWER VALUE Press and hold to scroll forward through selections *The "K" multiplier indicator appears below the digital reading on the display. Readout goes blank except for first active digit which will be 0 unless upper value was set before. VAR UPPE R SEL. VALUE 0 % 00 ANALOG K 6/05 ST 3000 HART Transmitter Release 300 User Manual 100 UNITS SET LOWER VALUE 156 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons Step 5 Action Press Increase button to select the next available digit value or Decrease button to select the previous digit value. Repeat this action until desired value is on display – use 9 for example purposes. Result First digit value setting is set to 9. VAR SEL. UPPE R VALUE % 0 90 100 SET ANALOG LOWER VALUE K Press and hold to scroll backward through values 6 Press and hold to scroll forward through values 0 1 2 3 4 5 6 7 8 9 Press UPPER VALUE button to lock-in first digit and activate next active digit. Readout now displays next active digit which will be zero unless upper value was set before. 7 UNITS VAR UPPE R SEL. VALUE % 0 0 90 Press Increase button to select the next available digit value or Decrease button to select the previous digit value. 100 UNITS SET ANALOG LOWER VALUE K Repeat this action until desired value is on display. 8 Press UPPER VALUE button to lock-in second digit and activate next active digit. Readout now displays next active digit which will be zero unless upper value was set before. VAR SEL. UPPE R VALUE 0 % 0 9 90 ANALOG K 6/05 ST 3000 HART Transmitter Release 300 User Manual 100 UNITS SE T LOWER VALUE 157 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons Step 9 Action Press Increase button to select the next available digit value or Decrease button to select the previous digit value. Repeat this action until desired value is on display – use 9 for example purposes. Result Next digit value setting is set to 9. VA R SEL. UPPE R VALUE 0 10 Press UPPER VALUE button to lock-in third digit and activate next active digit. % 9 9 90 LOWER VALUE K Press and hold to scroll backward through values Press and hold to scroll forward through values 0 1 2 3 4 5 6 7 8 9 Press Increase button to set digit to 1 or Decrease button to set it to BLANK. “1” digit value setting is set to 1. VAR SEL. UPPE R VALUE 0 % 1 99 90 100 LOWER VALUE K Press to set "1" digit as BLANK 12 Press UPPER VALUE button to lock-in “1” digit and activate sign segment. 13 Press Increase button to set sign segment to minus sign for negative values or Decrease button to set it to BLANK. for positive values. UNITS SET ANALOG Press to set "1" digit as 1 Readout now displays sign segment which will be BLANK for positive values unless upper value was set for negative (–) values before. VA R SEL. UPPER VALUE 0 Sign segment is BLANK for positive values and minus sign for negative values 6/05 UNI TS SET ANALOG Readout now displays next active digit which will be BLANK unless upper value was set to 1 before. 11 100 % 199 90 ST 3000 HART Transmitter Release 300 User Manual ANALOG K 100 UNIT S SET LOWER VALUE 158 Appendix A— Smart Meter Reference - Configuring Smart Meter Using Pushbuttons Step Action Result 14 Press UPPER VALUE button to lock in current settings as upper display value and return to previous display. Upper display limit setting is now complete. Display goes blank for a 1/2 second and returns to display readout equal to 50% output. For CUSTOM unit in transmitter with LINEAR output, you must set both lower and upper display limits for values to take effect. If you let either the lower or upper display limit time out (after 30 seconds), the meter discards both newly set values and reverts back to the previously set values. In this example, readout is 9, 990,000 CUSTOM unit for 50% display range of 0 to 19,990,000 CUSTOM for transmitter with LINEAR output. VAR UPPE R SEL. VALUE 0 % 99 90 ANALOG K 100 UNIT S SET LOWER VALUE • If you have not yet set the lower display limit value for CUSTOM unit in a transmitter configured for LINEAR output mode, the meter automatically enters the lower display setting function after it displays previously set value, if applicable. Go to Table A-7, Step 3. • If you have already set the lower display limit value, this completes the lower and upper display limits setting function for CUSTOM unit in a transmitter configured for LINEAR output mode. Meter returns to normal operation. • If you have just set the upper display limit for Flow unit or CUSTOM unit in a transmitter configured for SQUARE ROOT output mode, this completes the limit setting function. Meter returns to normal operation. 6/05 ST 3000 HART Transmitter Release 300 User Manual 159 Appendix A— Smart Meter Reference - Setting smart meter display using the HART communicator Setting smart meter display using the HART communicator Using the Hart Communicator to Configure the Smart Meter Display You can select an available engineering unit or enter a custom one including upper and lower limit settings for the smart meter’s digital readout using the HART communicator. Use the procedure in Table A-9 to setup the smart meter display with the HART communicator. Transmitter Output Conformity and Smart Meter Configuration Normally when using a differential type transmitter, you can select the transmitter’s output to represent a straight linear calculation or a square root calculation for flow measurement applications. This linear or square root output parameter selection is called output conformity or output form. (See Section 6 in this User manual for more details.) When configuring the smart meter to display the transmitter output measurement, there are certain rules to keep in mind which are dependent on the output conformity selection. These rules are described in the following paragraphs. Refer to Table A-5 also for meter set up restrictions. 1. The output conformity setting of the transmitter restricts the engineering units you can select for the smart meter display. When the transmitter is configured for an output conformity of LINEAR, you can select only pressure type engineering units. (See Table A-5.) When the transmitter is configured for an output conformity of SQUARE ROOT, you can select only flow type engineering units GPM and GPH. The percent (%) and custom engineering units can be selected regardless of output conformity configuration. 2. Additionally, the output conformity setting restricts the setting of the lower and upper display limits to represent transmitter’s 0 to 100% output. The table below shows the restrictions on setting display values for given engineering units and output conformity selections. Engineering Output Set Units code Conformity Lower Display Value? Upper Display Value? EU0 through EUC Linear No (set automatically) No (set automatically) Square root No (fixed at zero) Yes Linear Yes Yes (Pressure type units) EU0, EUD, EUE,and EUF (%, GPM, GPH, or Custom) Custom 3. If you change the transmitter’s output conformity, you must reconfigure the smart meter as outlined in Table A-9. See also “Meter/transmitter interaction” in this appendix. ATTENTION After making any adjustments to the smart meter, keep the transmitter powered for at least 30 seconds so that the new meter configuration is written to non-volatile memory. If power is turned off before 30 seconds, the changes may not be saved so that when the transmitter power is restored, the meter configuration will revert to the previous settings. 6/05 ST 3000 HART Transmitter Release 300 User Manual 160 Appendix A— Smart Meter Reference - Setting smart meter display using the HART communicator Table A-9 Smart meter display setup using HART communicator Step Action 1 Connect communicator across loop wiring and turn it on. 2 From “Online” menu, choose the following menu selections: • Device setup • Basic setup • Local meter 3 The “Local meter” display will appear. ST3000:PT 3011 Local meter 1 2 HELP Installed Units SAVE Yes % HOME ATTENTION You can set up the smart meter display using this procedure even if the meter is not installed in the transmitter. 4 Determine whether the current engineering unit (Units) for the meter display is correct for your process application. • If it is correct, press HOME (end of procedure). • If not, determine the desired engineering unit for the meter display from Table A-5. Also determine the correct output conformity selection (Linear or Square Root) for the transmitter output and meter EU. See Table A-5 for EU and output conformity selections. 5 To change output conformity: Press the left arrow key to show the “Basic setup” display. 6 Scroll down to highlight “PV xfer fnctn” (Output conformity) and select it by pressing the right arrow key. The “Transfer function” display appears. Select the correct Transfer function (Linear or Square root) and press ENTER. Press SEND to download change to the transmitter. 7 You will be warned that pressing OK will change device output. Press OK. 8 When prompted, return the loop to automatic control and press OK. The communicator will return to the “Basic setup” display. 9 To change engineering units for meter display: Scroll up to highlight “Local meter” and select it by pressing the right arrow key. 10 6/05 Select “Units” by pressing the number 2 key. ST 3000 HART Transmitter Release 300 User Manual 161 Appendix A— Smart Meter Reference - Setting smart meter display using the HART communicator Step 11 Action Scroll through the list of engineering units using the up and down arrow keys and select the desired units, then press ENTER. The available units are listed below for reference. % mbar mH2O inH2O bar gal/min mmHg g/Sqcm gal/h psi kg/Sqcm Custom kPa mmH2O MPa inHg Note: Be sure that the engineering unit that is selected is compatible with the output conformity selection in Table A-5. 12 Press SEND to download change to the transmitter. 13 If “Upper” and “Lower” appear on the screen, select Upper and enter the upper limit value for the meter display. Press ENTER. Select Lower and enter the lower limit value for the meter display. Press ENTER. Note: If square root output conformity is selected, the lower display limit is fixed at zero and cannot be changed. 14 Press SEND to download changes to the transmitter. ATTENTION If an error message appears, “Invalid unit occurred writing Units. Restore device value?” or “Invalid meter option occurred writing Lower. Restore device value?” You have tried to download an invalid parameter for the meter display. 6/05 ST 3000 HART Transmitter Release 300 User Manual 162 Appendix A— Smart Meter Reference - Typical smart meter indications Typical smart meter indications Table A-10 summarizes typical smart meter indications. Note that other combinations of status messages are possible. Table A-10 Summary of Typical Smart Meter Indications. Meter Indication What It Means Meter Indication What It Means No power applied. % 0 0 % 20 0 ANALOG 100 % 0 100 100 - - Normal display for transmitter in Analog mode with digital readout in inches of water. Display range is Over Limit. Transmitter output is over 200%. % 0 100 O-L % 99 90 (O-L is alternately displayed with the 200% value in engineering units.) In H 2 O K 0 Meter has detected transmitter output that is not-anumber. 100 FLOW Normal display for transmitter in HART mode and square root output. Digital readout is gallons per minute with 1000 multiplier. 0 % 10 0 .0 GPM 100 % Transmitter is in output mode. Bargraph and readout show value that was entered through the communicator. OUTPUT MODE K GPM 0 % 7 7 .9 CHECK STATUS 6/05 100 % Transmitter in HART mode is in non-critical status. Displayed value may not be valid. If display is “- - -” instead of a value, transmitter is in critical status. 0 % 20 0 .0 ST 3000 HART Transmitter Release 300 User Manual 100 % Input pressure equal to or greater than 200%. Display flashes between 200% (or corresponding value in EU) and O-L. Transmitter locks output at 200% and will go no higher regardless of input. 163 Appendix A— Smart Meter Reference - Operation error codes Operation error codes Table A-11 identifies possible meter error codes and what they mean. Table A-11 Smart Meter Error Codes and Descriptions. If error indication is . . . Then, it means You have tried to set local Zero or Span adjustment in a Series 100 transmitter that does not support this option. VAR SEL. SPAN UPPER VALUE % 0 E r0 100 SET ANALOG LOWER VALUE ZERO VAR SEL. UPPE R VALUE 0 % Er1 100 UNITS % ANALOG SET UPPE R VALUE 0 % Er 2 UNITS % SET LOWER VALUE VAR SEL. UPPE R VALUE % Er 3 ANALOG You have tried to select a process variable for the transmitter using the VAR SEL. button. The Variable Select button is nonfunctioning on the ST 3000 R300 transmitter. 100 ANALOG 0 You have tried to set a pressure type engineering unit for a transmitter in square root mode (FLOW) or have tried to set a flow type engineering unit for a transmitter in linear mode (pressure). After this error is displayed, the meter will return to the unit # (EU#) of the engineering unit it was displaying before the set function was invoked. You may then select another unit or exit in the normal fashion. LOWER VALUE VAR SEL. 6/05 UNITS 100 UNITS % SET LOWER VALUE You have tried to set Lower or Upper display limit for pressure type engineering units (EU1 to EUC), or Lower display limit for flow type engineering units (EUD, EUE) or CUSTOM unit (EUF) in transmitter configured for SQUARE ROOT output. Or, you have tried to set upper display limit for flow or Custom unit in transmitter with SQUARE ROOT output and URV set to zero (0). In SQUARE ROOT mode, the transmitter’s URV cannot equal zero. The Lower and Upper display limits only apply for CUSTOM (EUF) unit in transmitter configured for LINEAR output. The Upper display limit also applies for FLOW (EUD, EUE) and CUSTOM (EUF) units with transmitter in SQUARE ROOT mode, but the Lower display limit is fixed at zero (0) and cannot be changed. ST 3000 HART Transmitter Release 300 User Manual 164 Appendix A— Smart Meter Reference - Meter/transmitter interaction If error indication is . . . Then, it means You have tried to set a span value that is outside acceptable limits for your transmitter. VAR SEL. SPAN UPPER VALUE % 0 Er4 100 UNITS SET ANALOG LOWER VALUE ZERO VAR SEL. UPPE R VALUE 0 % Er 5 You have tried to invoke a smart meter set function with the transmitter’s Write Protect jumper in its Read Only position. You cannot make changes in the smart meter settings when the transmitter’s configuration is write protected. 100 UNITS % ANALOG SET LOWER VALUE Meter/transmitter interaction ATTENTION After making any adjustments to the smart meter, keep the transmitter powered for at least 30 seconds so that the new meter configuration is written to non-volatile memory. If power is turned off before 30 seconds, the changes may not be saved so that when the transmitter power is restored, the meter configuration will revert to the previous settings. Transmitter power cycling Cycling transmitter power OFF/ON will have no affect on meter configuration. The meter digital readout will be in the previously set engineering units and applicable upper and lower display limits will be intact when transmitter power is restored. Changing output conformity If you reconfigure the transmitter output conformity from SQUARE ROOT to LINEAR, the meter’s digital readout will automatically revert to the default engineering unit of percent (%) and the FLOW indicator will go out when the change is downloaded to the transmitter. Likewise, if you reconfigure the transmitter output conformity from LINEAR to SQUARE ROOT, the meter’s digital readout will automatically revert to the default engineering unit of percent (%) and the FLOW indicator will light when the change is downloaded to the transmitter. In either case, you must reconfigure the smart meter display as outlined in Table A-9 of this manual. 6/05 ST 3000 HART Transmitter Release 300 User Manual 165 - 6/05 ST 3000 HART Transmitter Release 300 User Manual 166 Appendix B— Configuration Record Sheet - ST 3000 R300 Smart Transmitter with HART Communications Appendix B— Configuration Record Sheet ST 3000 R300 Smart Transmitter with HART Communications Configuration Record Sheet Model Number: ______________________________________________ Series: ___________________________ Measurement Type: DP GP AP Measurement Range: __________________________________ Mode of Operation: ________________________ Tag Number: ___ ___ ___ ___ ___ ___ ___ ___ inH2O inHg ftH2O mmH2O mmHg psi bar mbar g/Sq cm kg/Sq cm Pa kPa torr atm MPa inH2O @ 4 degC PV Unit (Engineering Units): mmH2O @ 4 degC inH2O @ 60 degF PV LRV (Lower Range Value): 4mAdc = _____________________ PV URV (Upper Range Value): 20 mAdc = _____________________ Linear Square Root 0.00 0.16 0.32 0.48 1.00 2.00 4.00 8.00 16.0 32.0 deg R K PV Transfer Function (Output Conformity): PV Damping time (Seconds): SV Unit (Secondary variable): deg C PV AO Alarm Type (Failsafe Direction): Write Protect Option: Read and Write deg F Upscale (Hi) Downscale (Lo) Read only Poll Address ________ Configured By: _______________________________________ Date: ____ / ____ / ____ 6/05 ST 3000 HART Transmitter Release 300 User Manual 167 - 6/05 ST 3000 HART Transmitter Release 300 User Manual 168 Appendix C – Freeze Protection of Transmitters - Possible Solutions/Methods Appendix C – Freeze Protection of Transmitters Problem When water is present in the process fluid and ambient temperatures can fall below the freezing point (32°F/0°C), pressure transmitters and their piping require freeze protection. Transmitters may also require continuous heating, if the process fluid is tar, wax, or other medium which will solidify at normal ambient. However, uncontrolled steam or electric heating, in addition to wasting energy, can cause errors and accidentally destroy the transmitter. Possible Solutions/Methods Solution These two basic solutions are possible: Eliminate the need for heating the transmitter by keeping the freezable process fluid out of direct contact with transmitter. Control the steam or electric heat to prevent overheating on warm days while protecting against freeze-ups under the coldest conditions. The following paragraphs in this appendix describe a number of methods for implementing both solutions. Sealing liquid method The simplest and least costly method is to use a sealing liquid in the transmitter meter body and its impulse piping to the process. The small contact (interface) area between the sealing liquid and the process fluid reduces the mixing of the two fluids. You should select a sealing liquid that has a greater specific gravity than the process fluid to inhibit mixing. It also must have freezing and boiling temperatures compatible with the range of temperatures existing at the site, including the heated interface. WARNING The user must verify the compatibility of any sealing liquid with their process fluid. A reliable sealing liquid is a 50/50 percent (by volume) solution of ethylene-glycol and water. This solution has a specific gravity of 1.070 at 60°F (15°C), a freezing temperature of –34°F (–36°C), and a boiling temperature of +225°F (+106°C) at atmospheric pressure. Conventional antifreeze liquids for automobile coolant systems such as Prestone and Zerex are solutions of ethylene-glycol with some rust inhibitors and possibly leak sealants added; they may be used in place of pure ethylene-glycol. Another sealing liquid, used in many chemical plants, is dibutylphalate an oily-type liquid with a specific gravity of 1.045 at 70°F (21°C). It has a boiling point 645°F (340°C) and does not freeze so it can be used down to about –20°F (–30°C). Figures C-1 and C-2 show typical piping installations for this method. The process fluid must be heated above its freezing point. This is frequently done by lagging in (insulating) the connecting nipple, shut-off valve and “T” connector with the process piping. Where the process piping itself requires heating, a steam or electric trace is run around their components with consideration given to the boiling point of the sealing liquid. 6/05 ST 3000 HART Transmitter Release 300 User Manual 169 Appendix C – Freeze Protection of Transmitters - Possible Solutions/Methods 1/2" seamless pipe nipple 6" long 1/2" pipe cross with 2 pipe plugs 1/2" seamless pipe nipple 6" long 1/2" shut-off valve (thru port type desirable) 1/2" pipe cross with 2 pipe plugs 1/2" seamless pipe (slope at least 1" per foot downward 1/2" shut-off valve (thru port type desirable) 1/2" seamless pipe (short as possible to reduce head effect) 1/2" pipe union or coupling Process pressure transmitter 1/2" 3-valve manifold, standard type Differential pressure transmitter Figure C-1 Piping Installation for Sealing Liquid With Specific Gravity Heavier Than Process Fluid. 1/2" shut-off valve (thru port type desirable) 1/2" seamless pipe nipple 6" long Differential pressure transmitter 1/2" pipe cross with 2 pipe plugs 1/2" seamless pipe (slope at least 1" per foot downward 1/2" 3-valve manifold, standard type 1/2" seamless pipe nipple 6" long 1/2" pipe cross with 2 pipe plugs 1/2" seamless pipe (short as possible to reduce head effect) 1/2" shut-off valve (thru port type desirable) 1/2" pipe union or coupling Process pressure transmitter Make both HP and LP connections as shown. Figure C-2 Piping Installation for Sealing Liquid with Specific Gravity Lighter Than Process Fluid. The installation should be checked every 6 to 12 months to verify that the sealing liquid is at its required specific gravity. 6/05 ST 3000 HART Transmitter Release 300 User Manual 170 Appendix C – Freeze Protection of Transmitters - Possible Solutions/Methods Purging Purging air or water purges are commonly used to prevent viscous materials from clogging the impulse lines to pressure, level, or flow transmitters. The bubbler system, using a constant-air flow regulator, is particularly common on open tank liquid level applications. No heating of impulse lines or transmitter is required, but normal precautions are required to keep water out of the air supply system. Gas applications We must not overlook the possibility of condensate freezing in impulse lines to transmitters measuring gas flow or pressure. Although these components could be heated similar to water and steam applications, the simplest and best approach is to install transmitters so that they are self draining. This means that the impulse lines are connected to the lowest point in the transmitter meter body and the piping is sloped downward at least one inch per foot. (Side-connected transmitters with vent-drains at a lower point in the meter body must be regularly checked to assure condensate removal.) If the transmitter is located below the process taps (not recommended), piping must still run downward from the transmitter to the drain point and then up to the process as shown in Figure C-3. Steam or electric heating of the drain point will prevent pipe rupture due to freezing. Transmitter Figure C-3 Piping Installation for Gas Flow. Mechanical (diaphragm) seals Diaphragm seals on the impulse lines provide the most expensive, yet broadest application of all the methods. Similar in principle to the liquid seals, diaphragm seals eliminate the possibility of seal liquid carry-over into the process fluid. This eliminates the need for periodic maintenance checks to assure full and equal liquid seal legs. Welded diaphragm seals with special fills permit temperatures from –34° to 600°F (–36° to 315°C) at the process interface which can therefore be steam or electrically heated to assure viscosity of tars and similar high-freezing point fluids under the coldest conditions. You must be careful to specify large enough diaphragms to accommodate expansion and contraction of the fill fluid under varying temperatures without overextending the diaphragm into its stiff area. In general, conventional diaphragm seals are satisfactory for pressure ranges above approximately 75 psig with special large diameter elements required for low pressure or differential pressure measurements. You can lag (insulate) impulse lines and diaphragm seals with the process piping, but this practice is only common with liquid level applications involving highly viscous materials unsuitable for 1/2-inch impulse 6/05 ST 3000 HART Transmitter Release 300 User Manual 171 Appendix C – Freeze Protection of Transmitters - Possible Solutions/Methods lines. Use a tank-mounted flanged seal in such installations. Otherwise, it is more desirable to keep the capillary lengths short, the transmitter accessible for maintenance, and (for flow applications) the normal 3valve manifold assembly close to the transmitter for normal service checks. Thus, the impulse lines, valving and diaphragm seals with 1/2-inch connections would be electrically or steam traced, with high temperature steam permitted without damage to the transmitter. Figures C-4 and C-5 show typical piping layouts. The impulse piping, 3-valve manifold, and upper flanges of the metal diaphragm seals must be insulated and, where required, also heated by electric or steam. 1/2" , 3-valve manifold (standard type with suitable temperature rating) Differential pressure transmitter with metal diaphragm seals Figure C-4 Piping Installation for Differential Pressure Transmitter with Metal Diaphragm Seals. Impulse piping, shut-off valve, and diaphragm seal distance must be as short as possible and insulated along with the process pipe or vessel Shut-off Process pressure transmitter with metal diaphragm seal valve Pipe union or coupling Figure C-5 Piping Installation for Process Pressure Transmitter with Metal Diaphragm Seal. 6/05 ST 3000 HART Transmitter Release 300 User Manual 172 Appendix C – Freeze Protection of Transmitters - Possible Solutions/Methods Electric heating Most transmitters will withstand higher temperatures at their process interfaces (bodies) than at their electronics. Normally, it is impractical to heat transmitter bodies above 225 to 250°F (107 to 121°C) without radiant and conducted heat exceeding the rating at the electronics (normally 200°F/93°C). Prefabricated insulated enclosures with integral heating coils and thermostats set at 200°F (93°C) can assure viscosity of fluids which freeze below 180°F (82°C) while assuring safe transmitter operation. For water or similar lower-temperature mediums, the control can be set at 50°F (10°C) to save energy and call for heat only when temperature and wind conditions require. Systems can be engineered for uncontrolled, continuous electric heating to prevent water freezing at 0°F (– 18°C) and 20 mph wind velocity, while not exceeding 225°F (107°C) at the transmitter body at 90°F (32°C) ambient and zero wind velocity. The operating costs in energy for these systems usually exceed the high initial cost of the thermostat systems. Never attempt to maintain freeze points above 100°F (38°C) without thermostat controls since the Btu required to prevent freezing will normally exceed the body temperature rating under opposite extremes. Although systems are available with hollow bolts replacing the normal transmitter body bolts and containing electrical heating elements and thermostats, certain precautions are required with such arrangements. Some transmitter meter body bolts are too small to accept the available thermostats. Also thermostat settings should not approach the body temperature limit because the heat gradient across the meter body can be such that limits are exceeded adjacent to the heating elements even when the thermostat setting is lower. Electrical heating systems are available in explosionproof ratings for Class I, Group D, Division I and II installations. The possibility of electric supply failure must be considered. For this reason, we recommend using alarm devices with manual acknowledgment and reset. Figures C-6 and C-7 show typical piping installations. Electric heating cable Temperature sensor Temperature controller (thermostat) 1/2" , 3-valve manifold (standard type ) Differential pressure transmitter Insulated enclosure Figure C-6 Piping Installation for Differential Pressure Transmitter and Impulse Piping with Electric Heating and Control. 6/05 ST 3000 HART Transmitter Release 300 User Manual 173 Appendix C – Freeze Protection of Transmitters - Possible Solutions/Methods Shut-off Shut-off valve valve Electric heating cable Union or coupling Process pressure transmitter Insulated enclosure Temperature sensor Temperature controller (thermostat) Figure C-7 Piping Installation for Process Pressure Transmitter and Impulse Piping with Electric Heating Control. Steam heating Steam heating is perhaps the most common, yet potentially the most damaging method of protecting transmitters from freeze-ups. Since steam is generated for use in the overall process operation, it is considered an available by-product. The most important point to remember when steam heating transmitter meter bodies is the temperature of the steam that will be used and its pressure. We recommend that you review the next paragraph Superheated steam considerations to get a better understanding of the temperature problem with steam heating. In brief, do not assume that 30 psig steam is 274°F (134°C) and cannot damage a transmitter rated for 250°F (121°C). With steam heating, as with electrical, you should use insulated transmitter body housing, impulse piping and valves. It is common practice to use conventional steam traps on all steam heating systems. They permit live, superheated steam to enter the heating coils and piping down to the trap. You should also use conventional steam traps with lower pressure desuperheated steam which cannot overheat the transmitter under warmday conditions. If the heating pipes are not carefully installed to eliminate low spots and trapped condensate in the piping, they could freeze at low temperatures. All steam traps require a periodic maintenance program. Dirt, scale, and water softeners will cause traps to stick or jam which result in their either blowing steam continuously or not blowing steam, allowing condensate freeze-up in cold weather. When steam traps are used for cold-weather freeze protection of water lines, a thermostat controlled steam supply valve, which will shut off the steam at ambient temperatures higher than 50°F (10°C), will save steam and prevent overheating. A more general solution is offered by a specialized type of trap which throttles condensate flow based on its temperature. This backs up hot water in the radiator within the insulated transmitter enclosure, assuring temperatures no higher than the saturated steam at the reduced pressure. Models are available to set the condensate temperature from about 70° to 200°F (21° to 93°C). They must be located within 6 to 12 inches 6/05 ST 3000 HART Transmitter Release 300 User Manual 174 Appendix C – Freeze Protection of Transmitters - Possible Solutions/Methods (15 to 30 cm) of the transmitter body and, like all steam traps, they also require periodic maintenance. The engineering of this type system is more complex than electric systems since the amount of heat loss upstream of the CTV valve under varying conditions will determine the location of the steam/water interface. It could occur within the heater coil or further up the steam line, thus affecting the heating efficiency within the insulated enclosure. Therefore, steam control of materials which freeze or become too viscous above 100°F (38°C) should probably not be attempted without some experimenting with the specific piping layout used. Uncontrolled steam heating, even with the best pressure regulation and desuperheating of steam, should not be used to maintain transmitter temperatures above 100°F (38°C), since this type of fixed Btu input must either over or under-heat under normal ambient swings. As with electric heating, there are many types of commercial steam heating units available such as radiant heaters, hollow meter body studs or just tubing lagged to the impulse piping and transmitter body. The same precaution applies to the use of hollow studs as on the electrical versions. Figures C-8 and C-9 show typical piping installations. Table C-1 summarizes the temperature ranges for the various freeze protection systems. Steam Supply (low pressure) Pipe insulated with waterproof outer cover Shut-off valve 1/4" OD steam tracer line Impulse piping with 1/4" thick insulation Steam heat tracer line Pipe strap about every 15" Detail of Transmitter Impulse Piping Steam trap or condensate temperature valvle 1/2" , 3-valve manifold (standard type ) Differential pressure transmitter Insulated enclosure Condensate return from steam trap. All steam and condensate lines must always slope downward at least 1" per foot to prevent low spots which will trap condensate. All condensate lines must be protected from freezing. Figure C-8 Piping Installation for Differential Pressure Transmitter and Impulse Piping with Steam Heating. 6/05 ST 3000 HART Transmitter Release 300 User Manual 175 Appendix C – Freeze Protection of Transmitters - Possible Solutions/Methods Steam Supply (low pressure) 1/4" OD steam tracer line Pipe insulated with waterproof outer cover Shut-off valve Steam heat tracer line Impulse piping with 1/4" thick insulation Pipe strap about every 15" Shut-off valve Detail of Transmitter Impulse Piping Shut-off valve Union or coupling Process pressure transmitter Steam trap or condensate temperature valvle Insulated enclosure Condensate return from steam trap. All steam and condensate lines must always slope downward at least 1" per foot to prevent low spots which will trap condensate. All condensate lines must be protected from freezing. Figure C-9 Piping Installation for Process Pressure Transmitter and Impulse Piping with Steam Heating. Table C-1 Temperature Range of Freeze Protection Systems Operating Temperature Range οF οC 34 36 20 30 50 10 100 38 200 93 225 106 325 163 600 315 Liquid Seals Diaphragm Seals Ethylene DibutylGlycol Phthalate Steam Heating No Seals Trap CTV Valve Electric Heat No Control Thermostated Note: Broken lines indicate areas of caution. 6/05 ST 3000 HART Transmitter Release 300 User Manual 176 Appendix C – Freeze Protection of Transmitters - Possible Solutions/Methods Superheated steam considerations We must remember that the temperature of steam is 212°F (100°C) only at the normal atmospheric pressure of about 14.7 pounds per square inch absolute (psia). If the pressure of steam is increased above 14.7 psia, the temperature of the steam is also increased. For example, if we have steam at 30 pounds per square inch gage (psig), the steam temperature is 274°F (134°C). On industrial flow and pressure measurement applications, we may be required to use steam to heat the impulse piping to the flow or pressure transmitter, as well as the transmitter itself. For these applications, we must verify the temperature of the heating steam used. As an example, assume that steam at 100 psig saturated (338°F/170°C) is to be reduced to 30 psig pressure for the heating system. Too frequently, it is assumed that this pressure reduction will result in steam at 274°F (134°C), the temperature of saturated steam at 30 psig. Wrong! A reduction of the steam pressure will not appreciably decrease the initial steam temperature. In our example, we were talking about saturated steam in the main header from the boiler. But modern industrial boilers cannot afford to let waste heat go up the stack. After reaching the boiling point in the drum, the steam flows through a series of pipes in the second pass of the flue gas exit, extracting additional heat energy and being raised to a temperature higher than the saturation temperature at the same pressure. This is superheat and, depending on boiler design, it may amount to 50 to 300°F (10 to 149°C) above the saturated steam temperature. It also permits packing more heat energy in a given size pipe for transmission from the process. Thus, in the typical application, the problem of steam heating is compounded by the additional superheat in the main header. Specifically, when steam is reduced in pressure, it retains about the same latent heat or the same Btu’s/pound at the reduced pressure. Therefore, in our example, steam at 100 psig and 338°F (170°C) when reduced to 30 psig steam will have a temperature of 306°F (152°C) or a loss of only 32°F (18°C). This steam temperature can only be reduced by using a desuperheater. This device mixes cold water with the superheated steam to reduce its temperature by removing Btu’s per pound of water (steam). It is also possible to use temperature controlled steam traps, which actually allow the steam to condense to water and therefore reduce its temperature to a pre-set value. Table C-2 lists the various values of steam pressure, saturated steam temperatures at these pressures, degrees of superheat added to the saturated steam and finally the actual temperature of each when it is reduced to 30 psig steam. Table C-2 Steam Pressure Versus Steam Temperature Values Pressure (1) Saturated Temperature (2) Superheat Added (3) Final Steam Temperature (2) + (3) Actual Temperature of Steam When Reduced From (1)* to 30 psig psig °F °C °F °C °F °C °F °C 50 298 147 None None 298 147 290 143 100 338 170 100 55 438 225 420 215 150 366 185 120 66 486 251 460 234 200 387 198 150 83 537 281 500 260 400 448 231 200 111 648 342 600 316 600 489 254 250 139 739 393 660 349 * (1) equals pressure in column one with superheat added. 6/05 ST 3000 HART Transmitter Release 300 User Manual 177 - 6/05 ST 3000 HART Transmitter Release 300 User Manual 178 Appendix D —Hazardous Area Classifications - Introduction Appendix D —Hazardous Area Classifications Introduction Reference information Information is provided to clarify the Hazardous Location installation requirements in North America and internationally. An explanation of the applicable enclosure classification systems is also provided. North American Hazardous Location Standards NEC and CEC electrical codes Installation of electrical apparatus within hazardous (classified) locations of the United States is conducted under the provisions of the National Electrical Code (NEC), ANSI/NFPA 70, Article 500, and within Canada under the provisions of the Canadian Electrical Code (CEC) C22.1, Part 1, Section 18. Classes Hazardous (classified) locations, in both the United States and Canada, are categorized into one of three classes: Class I - Presence of flammable gases or vapors may be present in quantities sufficient to produce explosive or ignitable mixtures Class II - Presence of combustible dusts, powders or grains Class III - Presence of easily ignitable fibers or flyings Divisions The classes listed above are further categorized based upon the level of risk present: Division 1 - Locations in which hazardous concentrations of flammable gases or vapors - or combustible dust in suspension – are continuously, intermittently or periodically present under normal operating conditions. Division 2 - Locations in which flammable gases or vapors are present, but normally confined within closed containers or systems from which they can escape only under abnormal or fault conditions. Combustible dusts are not normally in suspension nor likely to be thrown into suspension. Examples Given the criteria above, the following examples are made: Class III, Division 1 - A class III, Division 1 location is a location in which easily ignitable fibers or material processing combustible flyings are handled, manufactured or used. Class III, Division 2 - A Class III, Division 2 location is a location in which easily ignitable fibers are stored or handled. 6/05 ST 3000 HART Transmitter Release 300 User Manual 179 Appendix D —Hazardous Area Classifications - North American Hazardous Location Standards Group classifications Flammable gases, vapors and ignitable dusts, fibers and flyings are classified into groups according to the energy required to ignite the most easily-ignitable mixture within air. Group classifications are as follows: Class I Group Classifications Group A - Atmospheres containing acetylene. Group B - Atmospheres containing hydrogen, fuel and combustible process gases containing more than 30 percent hydrogen by volume, or gases or vapors of equivalent hazard. Group C - Atmospheres such as ethyl ether, ethylene, or gasses or vapors of equivalent hazard. Group D - Atmospheres such as acetone, ammonia, benzene, butane, cyclopropane, ethanol, gasoline, hexane, methanol, methane, natural gas, naphtha, propane or gases or vapors of equivalent hazard. Class II Group Classifications Group E - Atmospheres containing combustible metal dusts including aluminum, magnesium, and their commercial alloys, and other metals of similarly hazardous characteristics. Group F - Atmospheres containing combustible carbonaceous dusts including carbon black, charcoal, coal or other dusts that have been sensitized by other materials so that they present an explosion hazard. Group G - Atmospheres containing combustible dusts not included in Group E or F, including flour, wood, grain, and other dusts of similarly hazardous characteristics. Methods of protection The following table summarizes available methods of protection for use in the given locations. Protection Concept 6/05 Designation Permitted Use Principle Explosionproof XP Division 1 & 2 Contains explosion and quenches flame Intrinsic Safety IS Division 1 & 2 Limit energy of sparks under normal and fault conditions Pressurized Type X and Y Division 1 & 2 Keeps flammable gas out Pressurized Type Z Division 1 & 2 Keeps flammable gas out Nonincendive NI Division 1 & 2 No arcs, sparks or hot surfaces under normal conditions ST 3000 HART Transmitter Release 300 User Manual 180 Appendix D —Hazardous Area Classifications - North American Hazardous Location Standards Temperature classification Equipment intended for installation directly within the hazardous (classified) location must also be classified for the maximum surface temperature that can be generated under normal or fault conditions as referenced to either 40 °C or the maximum operating ambient of the equipment (whichever is greater). The maximum surface temperature must be less than the minimum autoignition temperature of the hazardous atmosphere present. The temperature shall be indicated in identification numbers as listed in Table D-1. Table D-1 Temperature Identification Numbers (NEC/CEC) Maximum Temperature Identification Degrees C Degrees F Number 450 842 T1 300 572 T2 280 536 T2A 260 500 T2B 230 446 T2C 215 419 T2D 200 392 T3 180 356 T3A 165 329 T3B 160 320 T3C 135 275 T4 120 248 T4A 100 212 T5 85 185 T6 Intrinsically safe apparatus parameters 6/05 Vmax = Maximum safe voltage which can be applied to the apparatus terminals. Imax = Maximum safe current which can be applied to the apparatus terminals. Ci = Unprotected capacitance in the apparatus which can be considered present at the terminals. Li = Unprotected inductance in the apparatus which can be considered present at the terminals. ST 3000 HART Transmitter Release 300 User Manual 181 Appendix D —Hazardous Area Classifications - North American Hazardous Location Standards Associated apparatus parameters Voc = Maximum output voltage which can be delivered to the hazardous (classified) location. This voltage is the maximum from a single channel. Isc = Maximum output current which can be delivered to the hazardous (classified) location. This current is the maximum from a single channel. *Vt = Maximum output voltage which can be delivered to the hazardous (classified) location. This voltage is the maximum across any combination of terminals of a multiple channel configuration. *It = Maximum output current which can be delivered to the hazardous (classified) location. This current is the maximum through any combination of terminals of a multiple channel configuration. Ca = Maximum capacitance which can be connected to the apparatus. La = Maximum inductance which can be connected to the apparatus. *CSA does not recognize these parameters at this time Entity concept Under entity requirements, the concept allows interconnection of intrinsically safe apparatus to associated apparatus, not specifically examined in such combination. The criteria for interconnection is that the voltage (Vmax) and current (Imax), which intrinsically safe apparatus can receive and remain intrinsically safe, considering faults, must be equal to or greater than the voltage (Voc or Vt) and current (Isc or It) levels which can be delivered by the associated apparatus, considering faults and applicable factors. In addition, the maximum unprotected capacitance (Ci) and inductance (Li) of the intrinsically safe apparatus, including interconnecting wiring, must be less than or equal to the capacitance (Ca) and inductance (La) which can be safely connected to the associated apparatus. If these criteria are met, then the combination may be connected and remain intrinsically safe. Both FMRC and CSA define the entity parameters as listed in Tables D-2, D-3 and D-4 below: Factory Mutual (FM) Approval Code 1C Description • Explosionproof for Class I, Division 1, Groups A, B, C & D. Dust-Ignitionproof for Class II, Division 1, Groups E, F & G. Suitable for Class III, Division 1. Conduit seals required within 18” of enclosure, Group A only. • Intrinsically Safe for use in Class I, Division 1, Groups A, B, C & D; Class II, Division 1, Groups E, F & G; Class III, Division 1, T4 at 40°C, T3A at 93°C maximum ambient, when connected in accordance with Honeywell drawing 51205784. • Nonincendive for use in Class I, Division 2, Groups A, B, C & D; Suitable for Classes II & III, Division 2, Groups F & G, T4 at 93°C maximum ambient, hazardous locations. 42 Vdc max. • Environmental: Indoor and outdoor hazardous locations (NEMA 4X). 6/05 ST 3000 HART Transmitter Release 300 User Manual 182 Appendix D —Hazardous Area Classifications - North American Hazardous Location Standards Table D-2 FM Entity Parameters Intrinsic Safety Entity Parameters (1) Class I, II, III, Division 1 and 2, Groups A- G VMax ≤ 30 V IMax = 225 mA PMax = 1.2 W Ci = 4.2 nF Li = 0 With no integral indicator, or with integral smart meter option SM Li = 150 µH With analog meter option ME (1) Install in accordance with Honeywell drawing 51205784. Canadian Standards Association (CSA) Code 2J Description • Explosion Proof for Class I, Division 1, Groups B, C & D. Dust-Ignition-Proof for Class II, Division 1, Groups E, F & G; Class III, Division 1. Conduit seals not required. 42 Vdc max. • Intrinsically Safe for Class I, Groups A, B, C & D; Class II, Groups E, F & G; Class III, Divisions 1, T4 at 40°C, T3A at 93°C maximum ambient. Install per Honeywell drawing 51450806. • Suitable for Class I, II & III, Division 2, Groups A, B, C, D, E, F & G hazardous locations, T4 at 93°C. 42 Vdc max. • Environmental: Indoor and outdoor hazardous locations (Encl 4X). CSA Certified Barriers (1) Class I, II, III, Division 1 and 2, Groups 30V / 300 Ω 28V / 200 Ω A-G 20V / 150 Ω (1) 6/05 Install in accordance with Honeywell drawing 51450806. ST 3000 HART Transmitter Release 300 User Manual 183 Appendix D —Hazardous Area Classifications - International Electrotechnical Commission (IEC) Classifications International Electrotechnical Commission (IEC) Classifications IEC Classification of hazardous locations The IEC has established a number of recommendations applying to the construction of explosion protected electrical apparatus identified. These recommendations are found within IEC 79-0 through 79-15 and 79-28. For all EC countries as well as various neighboring countries (CENELEC member states), the European Standards EN 50 014 to EN 50 020 and EN 50 039 apply for the construction of explosion protected electrical apparatus. They were established on the basis of the IEC Recommendations, however in comparison they are much more detailed. Zones Defined within IEC 7-10, Hazardous locations are categorized into three zones: Zone 0 - Explosive gas atmosphere is present continuously, or is present for long periods. Zone 1 - Explosive gas atmosphere is likely to occur in normal operation. Zone 2 - Explosive gas atmosphere is not likely to occur in normal operation and, if it does occur, it will exist for a short period only. Groups Flammable gases, vapors and mists are classified into groups according to the energy required to ignite the most easily ignitable mixture within air. Apparatus is grouped according to the atmospheres it may be used within as follows: 6/05 Group IIC - Atmospheres containing acetylene, hydrogen, fuel and combustible process gases or vapors of equivalent hazard. Group IIB - Atmospheres such as ethyl ether, ethylene, or gasses or vapors of equivalent hazard. Group IIA - Atmospheres such as acetone, benzene, butane, cyclopropane, ethanol, gasoline, hexane, methanol, methane, natural gas, naphtha, propane or gases or vapors of equivalent hazard. ST 3000 HART Transmitter Release 300 User Manual 184 Appendix D —Hazardous Area Classifications - International Electrotechnical Commission (IEC) Classifications Methods of protection The following table summarizes available methods of protection for use in given locations. Protection Concept Designation Permitted Use Principle Flameproof d Zone 1 & 2 Contains explosion and quenches flame. Intrinsic Safety ia Zone 0, 1 & 2 Limit energy of sparks under 2 faults. Intrinsic Safety ib Zone 1 & 2 Limit energy of sparks under 1 fault. Pressurized p Zone 1 Keeps flammable gas out. Encapsulation m Zone 1 & 2 Keeps flammable gas out. Increased Safety e Zone 1 & 2 No arcs, sparks or hot surfaces. Powder Filled q Zone 1 & 2 Contains explosion and quenches flame. Oil Immersion o Zone 1 & 2 Keeps flammable gas out. non-sparking nA Enclosed Break nC Zone 2 Contains explosion and quenches flame. Limited Energy nA Zone 2 Limit energy of sparks and surface temperature under normal conditions. Restricted Breathing nR Zone 2 Keeps flammable gas out. No arcs, sparks or hot surfaces under normal conditions. Temperature classification Equipment intended for installation directly within the hazardous location must also be classified for the maximum surface temperature that can be generated under normal or fault conditions as referenced to the maximum operating ambient of the equipment. The maximum surface temperature must be less than the minimum autoignition temperature of the hazardous atmosphere present. The temperature shall be indicated in identification numbers as listed in Table D-3. Table D-3 Temperature Identification Numbers (IEC) Maximum Temperature 6/05 Identification Degrees C Degrees F Number 450 842 T1 300 572 T2 200 392 T3 135 275 T4 100 212 T5 85 185 T6 ST 3000 HART Transmitter Release 300 User Manual 185 Appendix D —Hazardous Area Classifications - International Electrotechnical Commission (IEC) Classifications Certification and conformity details CENELEC / LCIE Certification Code Description 3D • Flameproof, Supply ≤ 45 Vdc, IP 66/67 3A • Intrinsically Safe EEx d IIC T6 EEx ia IIC T5, −40 ≤ Tamb ≤ 93°C • Flameproof, Supply ≤ 45 Vdc, IP 66/67 EEx d IIC T6 LCIE Intrinsic Safety Entity Parameters (1) Ui ≤ 30 V II = 100 mA PI = 1.2 W Ci = 4.2 nF Ri = 0 Li = 0 With no integral indicator, or with integral smart meter option SM Li = 150 µH With analog meter option ME (1) Install in accordance with Honeywell drawing 51450805. Standards Australia (LOSC) Certification Code 4H Description • Intrinsically Safe Ex ia IIC T4 Class I Zone 0 • Flameproof Ex d IIC T6 Class I Zone 1 • Non-Sparking Apparatus - Type of Protection ‘n’ Ex n IIC T6 Class I Zone 2 LOSC Intrinsic Safety Entity Parameters Ui ≤ 30 V II = 100 mA PI = 1.2 W Ci = 4.2 nF 6/05 Li = 0 With no integral indicator, or with integral smart meter option SM Li = 150 µH With analog meter option ME ST 3000 HART Transmitter Release 300 User Manual 186 Appendix D —Hazardous Area Classifications - Enclosure Ratings Zone 2 (Europe) Declaration of Conformity Code 3N Description • Electrical Apparatus With Type of Protection “n” per IEC 79-15. Ex II 3 GD T(1) X (Council Directive 94/9/EC) −40 ≤ Ta ≤ 93°C. Enclosure IP 66/67 Zone 2 Parameters Ui ≤ 30 V II = 22 mA PI = 1.2 W Temp. Code (1) T4 at Ta 93°C Maximum Ambient Temp. Code (1) T5 at Ta 80°C Maximum Ambient Temp. Code (1) T6 at Ta 65°C Maximum Ambient Enclosure Ratings NEMA and IEC Recognition The NEMA (National Electrical Manufacturer’s Association) enclosure classifications are recognized in the US. The IEC Publication 529 Classifications are recognized throughout Europe and those parts of the world that use the IEC standards as a basis for product certifications. The following paragraphs provide a discussion of the comparison between NEMA enclosure type numbers and IEC enclosure classification designations. IEC Classifications IEC Publication 529, Classification of Degrees of Protection Provided by Enclosures, provides a system for specifying the enclosures of electrical equipment on the basis of the degree of protection provided by the enclosure. IEC 529 does not specify degrees of protection against mechanical damage of equipment, risk of explosion, or conditions such as moisture (produced for example by condensation), corrosive vapors, fungus, or vermin. IEC Designations Basically, the IEC designation consists of the letters IP followed by two numerals. The first characteristic numeral indicates the degree of protection provided by the enclosure with respect to persons and solid foreign objects entering the enclosure. The second characteristic numeral indicates the degree of protection provided by the enclosure with respect to the harmful ingress of water. NEMA Standards NEMA Standards Publication 250, Enclosures for Electrical Equipment (1000 Volts Maximum), does test for environmental conditions such as corrosion, rust, icing, oil, and coolants. For this reason, and because the tests and evaluations for other characteristics are not identical, the IEC enclosure classification designations cannot be exactly equated with NEMA enclosure type numbers. 6/05 ST 3000 HART Transmitter Release 300 User Manual 187 - Table D-4 provides an approximate conversion from NEMA enclosure type numbers to IEC enclosure classification designations. The NEMA types meet or exceed the test requirements for the associated IEC classifications; for this reason the Table cannot be used to convert from IEC classifications to NEMA types. Table D-4 NEMA Enclosure Type Numbers and Comparable IEC Enclosure Classification NEMA Enclosure Type Number IEC Enclosure Classification Designation 1 IP 10 2 IP 11 3 IP 54 3R IP 14 3S IP 54 4 and 4X IP 56 5 IP 52 6 and 6P IP 67 12 and 12K IP 52 13 IP 54 NOTE: This comparison is based on tests specified in IEC Publication 529 6/05 ST 3000 HART Transmitter Release 300 User Manual 188 Index - Index A Analog meter connections, 37 Approvals, 35 Canadian Standards Association (CSA), 183 Factory Mutual (FM), 182 D B Barrier diaphragms, 97 inspecting and cleaning, 97 C Calibration analog output signal, 108 range, 109 reset, 111 Certification CENELEC / LCIE, 186 Standards Australia (LOSC), 186 Zone 2 (Europe) Declaration of Conformity, 187 Communication errors, 115 Communications request/response format, 7 starting, 41 transmitter/communicator, 7 Communicator connections, 68 connections to transmitter, 40 disconnecting, 64 display symbols, 53 function keys, 53 keyboard, 52 memory module or data pack, 46 menu summary, 51 online menu summary, 50 Software compatibility, 39 viewing/entering device information, 59 Configuration device information, 59 LRV and URV, 57 PV damping, 62 PV engineering units, 56 PV transfer function (output conformity), 60 SV units (meter body temperature), 63 tag number, 55 Configuration data 6/05 reviewing, 42 Configuration database, 46 Configuration parameter summary, 48 Constant-current source mode, 67 Critical failures, 114 clearing critical failures, 118 Damping time, 62 adjusting, 62 Damping Time Constant, 49 Database save/restore, 93 Device Information, 49 Diagnostic messages, 114 communication errors, 114 critical failures, 114 non-critical failures, 114 Diaphragm seals, 171 E Electric heating, 173 Electrical codes IEC and CENELEC, 184 NEC and CEC, 179 EMC Directive, 13 Enclosure Ratings, 187 Enclosures IEC classification, 188 NEMA standards, 188 Engineering units, 56 pre-programmed, 56 selecting, 56 F Failsafe direction, 90 Failure mode alarm jumper, 43 Flange adapter installing, 32 Flange connections description, 31 Flange mounted transmitter, 25 Mounting, 25 Flow engineering units Smart meter, 148 Flow measurement application, 69 Freeze protection, 169 ST 3000 HART Transmitter Release 300 User Manual 189 Index - Operation data, 87 failsafe output direction, 89 input pressure, 88 message (or scratchpad) area, 89 output, 88 temperature, 89 upper and lower range limits, 88 Output conformity, 49, 60 selecting, 60 Output conformity and smart meter configuration, 148 Output meter options, 37 Output mode, 67 H Hazardous location installation, 36 Hazardous location requirements, 179 J Jumpers failsafe direction, 43 repositioning procedure, 90 L Lightning Protection, 36 Liquid level measurement application, 83 differential pressure (DP), 73, 75 gauge pressure (GP), 78 remote diaphragm seals, 83 Local smart meter options, 10 Local zero and span adjusting (procedure), 144 Loop wiring, 37 LRV, 57 keying in, 57 setting to applied pressure, 58 LRV (Lower Range Value), 48 M Maintenance routines, 97 Master reset, 118 Meter body replacing, 103 Model number format, 4 Mounting suggested location, 29 Mounting area considerations, 14 Mounting transmitter bracket mounting, 18 flange mounting, 25 flush mounting, 24 Models STA122, STA922, 21 remote diaphragm seal mounting, 26 Multidrop mode, 49, 64 N Non-critical failures, 115 Nonvolatile memory, 46 O Operation data access, 87 6/05 P Parts identification, 119 Piping, 28 guidelines, 31 Poll address, 49, 64 Potential noise sources, 14 Power supply voltage operating range, 33 Pressure measurement application absolute pressure (AP), 81 differential pressure (DP), 71 gauge pressure (GP), 78 Pressure ratings, 16 Printed Wiring Assembly (PWA) replacing, 100 Process connections summary, 30 Process head bolt torque ratings, 100 PV engineering unit, 48 R Recommended spare parts, 137 Restore database, 95 S Sealing liquid, 169 SM 3000 smart meter connections, 38 Smart meter configuration and output conformity, 148 configuration using meter pushbuttons, 147 engineering units code, 148 error codes, 164 indications, 163 meter/transmitter interaction, 165 selecting engineering units, 149 setting display of LRV (using meter pushbuttons), 151 setting display of URV (using meter pushbuttons), 155 setting display using HART communicator, 160 ST 3000 HART Transmitter Release 300 User Manual 190 Index - Smart meter display, 44 description, 141 operating conditions and specifications, 143 Smart meter option (option SM), 140 Software version compatibility, 39 Solution Support Center, iv Span, 57, 58 Square root dropout, 61 Square root output, 60 ST 3000 smart transmitter, 2 Start-up, 66 AP transmitter pressure measurement application, 81 DP transmitter flow measurement application, 69 liquid level measurement application, 73, 75 pressure measurement application, 71 DP transmitter (remote seals) liquid level measurement application, 83 GP transmitter liquid level measurement application, 78 pressure measurement application, 78 Start-up tasks reference, 12 Static electricity damage, 90 Status, 89 clearing critical status, 118 Steam heating, 174 Superheated steam considerations, 177 T Tag number, 48, 55 Temperature Limits Operating, 14 Three-valve manifold piping, 28 Torque ratings, 100 Transmitter failure mode alarm jumper, 43 6/05 mounting, 17 operating temperature limits, 14 piping, 28 pressure ratings, 16 start-up, 66 wiring, 33 write protection option, 43 Transmitter models, 5 Transmitter types, 4 Turndown Ratio, 62 U URV, 57 keying in, 57 setting to applied pressure, 58 URV (Upper Range Value), 48 V Vibration sources, 14 W Wiring transmitter connections, 34 Working memory, 46 Write protection option, 90 Writing data in the message area, 92 Z Zero and span adjust options, 10 Zero corrects, 21 Zero shift, 21 ST 3000 HART Transmitter Release 300 User Manual 191 Addendum to ST 3000 Smart Transmitter Release 300 with HART Communications Option User Manual 34-ST-25-17 Overview Two new models have been added to the family of ST3000 Smart Transmitters: Gauge Pressure Model STG19L Gauge Pressure Model STG99L. Each of these has an Upper Range Limit (URL) of 10000 psi (690 bar), which is significantly higher than previously available models. Also, each of these new models has significantly higher ratings for Maximum Working Pressure (10000 psi, or 690 bar) and Overpressure (15000 psi, or 1034 bar). The burst pressure is rated at 26000 psi (1793 bar). Except for the higher operating range, each of these two new models includes physical and functional features similar to those of closely related family members (STG1xL and STG9xL). With the exceptions noted in this addendum, all parts of User Manual 34-ST-25-17 apply to these new models. Because of the similarities between new and existing models, these new devices can be used as direct replacements in circumstances that require higher pressure capabilities. Details of pressure ranges for these new models are specified in “Additions and Changes to the Manual”, below. Additions to the User Manual The additions to User Manual 34-ST-25-17 that relate to the new Gauge Pressure transmitter models are given in Table 1 of this addendum. Use the information in Table 1 to reference and annotate your User Manual. Table 1 – Additions to the User Manual Page # in User Manual 15 Sub-Section 3- Preinstallation Considerations – Considerations for ST 3000 Transmitter Table 4 Operating Temperature Limits (Transmitters with Silicone Fluid Fill DC200) 16 3- Preinstallation Considerations – Considerations for ST 3000 Transmitter Description of Change In the left column of Table 4, under the heading Gauge Pressure, add the information as indicated by the highlights in Exhibit A, below. (Note: Ranges for Ambient Temperature and Process Interface Temperature are the same as for other models in each series.) In the row of Table 5 titled Gauge Pressure, add the information as highlighted in Exhibit B, below. Pressure Ratings Table 5 Transmitter Overpressure Ratings 120 12.1 Replacement Parts Figure 40 Major ST3000 Smart Transmiter Parts Reference At the right of Figure 40, under LGP Models, references to Figure 48 have been added for ST 3000 Transmitters STG19L and STG99L. NOTE: The use of Figure 48 (and corresponding Table 60) is the same for all LGP meter bodies, including Models STG19L and STG99L. That is, the model number of the meter body is specified on its nameplate. In Figure 40, add the information highlighted in Exhibit C in this addendum . Exhibit A –Additions to Table 4 Transmitter Type and Model Ambient Temperature Process Interface Temperature °C °F °C °F -40 to 70 -40 to 158 -40 to 70 -40 to 158 STD125 -40 to 85 -40 to 185 -40 to 85 -40 to 185 STD120, STD130, STD170 -40 to 85 -40 to 185 -40 to 125 -40 to 257 STD904, STD924, STD930, STD974 -40 to 85 -40 to 185 -40 to 125 -40 to 257 STG140, STG170, STG180 -40 to 85 -40 to 185 -40 to 125 -40 to 257 STG14L, STG17L, STG18L, -40 to 85 -40 to 185 -40 to 110 -40 to 230 -40 to 85 -40 to 185 -40 to 150 † -40 to 302 † -15 to 65 5 to 149 -15 to 95 †† 5 to 203 †† -40 to 85 -40 to 185 -40 to 125 -40 to 257 -40 to 85 -40 to 185 -40 to 110 -40 to 230 Draft Range STD110 Differential Pressure Gauge Pressure STG19L STG14T STG93P STG944, STG974 STG90L, STG94L, STG97L, STG98L, STG99L Exhibit B –Additions to Table 5 Transmitter Type Upper Range Limit (URL) Maximum Working Pressure Rating Overpressure Rating Draft Range 10 inches H2O (25 mbar) 50 psi (3.5 bar) 50 psi (3.5 bar) (No overpressure protection is provided) Differential Pressure 400 inches H2O (1 bar) 3000 psi (210 bar) 3000 psi (210 bar) 100 psi (7 bar) 3000 psi (210 bar) 3000 psi (210 bar) 3000 psi (210 bar) 3000 psi (210 bar) 3000 psi (210 bar) 100 psi (7 bar) 100 psi (7 bar) 150 psi (10.3 bar) 300 psi (21 bar) 300 psi (215 bar) 450 psi (31 bar) 500 psi (35 bar) 500 psi (35 bar) 750 psi (52 bar) 3000 psi (210 bar) 3000 psi (210 bar) 4500 psi (310 bar) 6000 psi (415 bar) 6000 psi (415 bar) 9000 psi (620 bar) 10000 psi (690 bar) 10000 psi (690 bar) 15000 psi (1034 bar) 780 mmHg Absolute (1 bar) 780 mmHg Absolute (1 bar) Full vacuum to 1550 mmHg Absolute (2 bar) 500 psia (35 bar) 500 psia (35 bar) 750 psia (52 bar) Gauge Pressure Absolute Pressure Exhibit B –Additions to Table 5 ST 3000 Release 300 Elect ronic Housing Assembly: See Figures 42 and 43 Meter Bodies DP Models STD110 STD120 STD125 STD130 STD170 STD904 STD924 STD930 STD974 See Figure 44 44 44 44 44 44,45 44,45 44,45 44,45 Flange Mounted Models STF128 STF132 STF12F STF13F STF14F STF924 STF932 STF92F STF93F Single Head GP Models STG140 STG170 STG180 See Figure 46 46 46 Single Head AP Models STA122 STA140 STA922 STA940 See Figure 46 46 46 46 See Figure 50 50 50 50 50 50 50 50 50 Dual Head GP Models STG944 STG974 See Figure 47 47 Remote Diaphragm Seal Models STR12D LGP Models STR13D STR14G STR14A STR17G STR93D STR94G Attention: No replacement meter body is available for Remote Diaphragm Seal Models. High Temperature Models STG14T STF14T LGP Models STG14L STG17L STG18L STG19 L STG90L STG94L STG97L STG98L STG99 L See Figure 48 48 48 48 48 48 48 48 48 Flush Mount GP Models STG93P See Figure 49 See Figure 51 51 Figure 40 major ST 3000 Smart Transmitter Parts Reference ST 3000 Smart Transmitter 34-ST-99-24 ® Release 300 with HART Communications Option Transmitter Models: STD110, STD120, STD125, STD130, STD170, STD924, STD930 Overview 10/04 Addendum (to User Manual 34-ST-25-17) Replacement Meterbody and Heads The ST 3000 Pressure Transmitter, Models: • • STD110, STD120, STD125, STD130, and STD170 STD924 and STD930 with optional Tantalum or Monel diaphragm is now being shipped with newly designed meter body and process heads. If a replacement meter body is needed, it should be ordered from the Model Number stated on the meter body nameplate. This number includes the letter “S” after the model number; for example, STD110S-xxx. This new transmitter is functionally identical to previous models in that the working ranges (Lower Range Limit to Upper Range Limit) and intended applications have not changed. However, the specifications for the maximum Pressure Rating and for the Overpressure Rating have been enhanced in all models except the draft range transmitter. A summary of specifications is given in Table 5. The new versions, which will continue as Models STD110, STD120, STD125, STD130, STD170, STD924, and STD930, differ only in the physical size and form of the meter body, process head, and associated components. With exceptions noted in this addendum, information given in User’s Manual 34-ST-25-17 applies also to this newer design. Installation, operation, maintenance, calibration, and troubleshooting tasks remain virtually the same as for the previous version. Differences appear primarily in torque specifications when replacing meter bodies, and in part numbering and parts recognition when replacing components or assemblies. Related Publications 10/04 This addendum provides details for parts replacement that span a variety of applications of the Models STD110, STD120, STD125, STD130, STD170, STD924, and STD930. For Series 100 Models ST 3000 Smart Pressure Transmitter Series 100 Differential Pressure Models Specification and Model Selection Guide 34-ST-03-60 For Series 900 Models ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models Specification and Model Selection Guide 34-ST-03-65 34-ST-99-37 (Addendum to 34-ST-25-17) 199 of 124 Additions to the User Manual The additions to User Manual 34-ST-25-17 that relate to the newly designed meter body and process heads are given in Table 1 of this addendum. Use the information in Table 1 to reference and annotate your User Manual. Table 1 Additions to the User Manual Page # in User Manual Sub-Section 16 Considerations for ST 3000 FF Transmitter Table 5 Transmitter Overpressure Ratings Description of Change The Maximum Working Pressure Rating and the Overpressure Rating has been enhanced for all models included in this addendum except for the draft range transmitter. For more information, refer to Table 5. 32 98-100 4 – Installation - Piping ST 3000 Transmitter In Step 5, do not use the torque specification of 47.5 to 54 N·m (35 to 40 lb-ft). Table 13 Installing Flange Adapter Instead, torque Flange Adapter bolts evenly to 47,5 N•m +/- 2,4 N•m (35 Lb-Ft +/- 1.8 Lb-Ft). 9 - Maintenance - Inspecting and Cleaning Barrier Diaphragms Table 41 Inspecting and Cleaning Barrier Diaphragms In Step 8 of Table 41, do not use specifications for head torque given in Table 42. Instead, torque head bolts/nuts to the specifications given in Table 2 of this addendum. Table 42 Process Head Bolt Torque Ratings 103-105 9 - Maintenance Replacing Meter Body Instead, torque head bolts/nuts to the specifications given in Table 2 of this addendum. Table 44 Replacing Meter Body Only 123-125 9 - Parts List – Replacement Parts Figure 44 Series 100 and Series 900 DP Meter Body for Models STD924 & STD930 C, D, G, H, K, and L STD974 Table 55 Parts Identification for callouts in Figure 44. Figure 44 illustrates the replacement parts available for the previous style of the transmitter, and Table 55 provides part numbers and descriptions for the parts called out in Figure 44. For the new style, use Figure 1 of this addendum to locate replacement parts, and use Table 3 of this addendum for part numbers and descriptions. For applicability of parts, refer to: ST 3000 Smart Transmitter Series 100 Differential Pressure Models Specification and Model Selection Guide 34-ST-03-60 ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models Specification and Model Selection Guide 34-ST-03-65 Table 2 Torque Table - Process Head Bolts/Nuts Bolt Type 51452557-001 5142557-002 and –003 51452557-004 (Carbon Steel standard; no option specified) (NACE [“CR” option] and Non-NACE [“SS” option] Stainless Steel) (B7M Alloy Steel [“B7” option]) 51451864XXXX except …XXX5 (All STD 3000 and SMV 3000 Transmitters except STD110) 67,8 N•M +/- 3,4 N•M 56,9 N•M +/- 2,8 N•M 48,8 N•M +/- 2,4 N•M (50.0 Lb-Ft +/- 2.5 LbFt) (42.0 Lb-Ft +/- 2.1 Lb-Ft) (36.0 Lb-Ft +/- 1.8 Lb-Ft) 51451864XXX5 (Model STD110 Transmitter [draft range] only) 20,3 N•M +/- 1,0 N•M 20,3 N•M +/- 1,0 N•M 20,3 N•M +/- 1,0 N•M (15.0 Lb-Ft +/- 0.8 LbFt) (15.0 Lb-Ft +/- 0.8 Lb-Ft) (15.0 Lb-Ft +/- 0.8 Lb-Ft) Meterbody Type Figure 1 ST 3000 Model STD110, STD120, STD125, STD130, STD170, STD924, STD930 (Rev S or greater) Table 3 Parts Identification for Callouts in Figure 1 Key No. 1 Part Number Specify complete model number from nameplate plus R300 Specify complete model number from nameplate plus R300 Description Series 100 Meter Body replacement kit includes: Qty/ Unit 1 Meter body (without Process Heads) Neoprene O-ring, Meter Body to Electronica Housing (K7; Part no. 30752785-007; 1/unit) Process Head Gasket; PTFE (K6; Part No. 51452560-002; 2/unit) Series 900 Meter Body replacement kit includes: 1 Meter body (without Process Heads) Neoprene O-ring, Meter Body to Electronica Housing (K7; Part no. 30752785-007; 1/unit) Process Head Gasket; PTFE (K6; Part No. 51452560-002; 2/unit) Bolting Kits: 51452866-001 Bolts and Nuts Kit, Carbon Steel 51452866-002 Bolts A286 SS (NACE) and Nuts, 304 SS (NACE) Kit 51452866-003 Bolts, 316 SS (non-NACE) and Nuts, 316 SS (non-NACE) Kit 51452866-004 Bolts B7M and Nuts 7M Kit Each Bolts and Nuts Kit includes: Kc K4 K8 ································ Bolt, Hex head, 7/16-20 UNF, 1.50 Inches long (Flange Adapter)········ 4 ································ Nut, Hex, 7/16 UNC (Process Head)···················································· 4 ································ Bolt, Hex Head, 7/16 UNC X 3.25 inches long (Process Head)············ 4 Vent and Plug Kits: 30753785-001 Drain and Plug Kit, stainless steel 30753787-001 Drain and Plug Kit, Monel 30753786-001 Drain and Plug Kit, Hastelloy C Each Drain and Plug Kit includes: K1 ································ Pipe Plug ···················································································· 4 K2 ································ Vent Plug ····························································································· 2 K3 ································ Vent Bushing ······················································································· 2 Meterbody Gasket Kits: K6 51452865-001 Meterbody Gasket Kit (PTFE Material); Kit includes: 51452865-002 Meterbody Gasket Kit (Viton Material); Kit includes: ································· Gasket, Process Head ········································································· 6 Ka ································· Gasket, Flange Adapter ······································································· 6 K7 ································· O-Ring, Meterbody to Electronics Housing ·········································· 3 Process Head Gasket Kits: Key No. Part Number Description K6 51452868-001 Gasket only, Process Head (12 PTFE Gaskets/pack) 12 K6 51452868-002 Gasket only, Process Head (6 Viton Head O-Rings) 6 K6 51452868-007 Gasket only, Process Head Graphite Gasket (use only as replacement of existing graphite gasket) 6 Qty/ Unit Flange Adapter Gasket Kits: Ka 51452868-004 Gasket only, Flange Adapter, 6 PTFE Adapter Gaskets 6 Ka 51452868-005 Gasket only, Flange Adapter, 6 VITON Adapter O-Rings 6 Ka 51452868-0078 Gasket only, Flange Adapter Graphite Gasket (use only as replacement of existing graphite gasket) 6 ½ inch NPT Flange Adapter Kits: Flange Adapter Kit, with: 51452867-110 SS Flange Adapters and with carbon steel bolts 51452867-210 SS Flange Adapters and with A286 SS (NACE) bolts 51452867-310 SS Flange Adapters and with 316 SS (non-NACE) bolts 51452867-410 SS Flange Adapters and with B7M alloy steel bolts 51452867-150 Monel Flange Adapters and with carbon steel bolts 51452867-350 Monel Flange Adapters and with 316 SS (non-NACE) bolts 51452867-130 Hastelloy C Flange Adapters and with carbon steel bolts 51452867-330 Hastelloy C Flange Adapters and with 316 SS (non-NACE) bolts Each 1/2-inch NPT Flange Adapter Kit includes: Ka ··································· Gasket, Flange Adapter ································································ 2 Kb ··································· 1/2-inch NPT Flange Adapter ························································· 2 ··································· Bolt, hex head, 7/16-20 UNF, 1.50 inches long, Flange Adapter ·· 4 Kc Blind Flange Adapter Kits: 51452867-100 SS Blind Flange Adapter Kit, with Carbon Steel bolts 51452867-200 SS Blind Flange Adapter Kit, with A286 SS (NACE) bolts 51452867-300 SS Blind Flange Adapter Kit, with 316 SS (non-NACE) bolts 51452867-400 SS Blind Flange Adapters and B7M alloy steel bolts Each Blind Flange Adapter Kit includes: Ka ··································· Gasket, Flange Adapter ································································ 2 Kb ··································· Blind Flange Adapter ······································································ 2 ··································· Bolt, hex head, 7/16-20 UNF, 1.50 inches long, Flange Adapter ·· 4 Kc Table 4 Process Head Assembly Kits Key No Part Number 51452864-010 51452864-012 K1 K2 K3 K5 K6 Ka Description Process Head Kits: Process Head Assembly Kit, with PTFE Gasket and with: Carbon steel head (zinc plated) without side vent/drain Carbon steel head (zinc plated) with side vent/drain 51452864-020 51452864-022 Stainless steel head without side vent/drain Stainless steel head with side vent/drain 51452864-030 51452864-032 Hastelloy C head without side vent/drain Hastelloy C head with side vent/drain 51452864-040 51452864-042 Monel head without side vent/drain Monel head with side vent/drain 51452864-050 51452864-052 Carbon steel head (nickel plated) without side vent/drain Carbon steel head (nickel plated) with side vent/drain 51452864-110 51452864-112 Process Head Assembly Kit, with VITON Gasket and with: Carbon steel head (zinc plated) without side vent/drain Carbon steel head (zinc plated) with side vent/drain 51452864-120 51452864-122 Stainless steel head without side vent/drain Stainless steel head with side vent/drain 51452864-130 51452864-132 Hastelloy C head without side vent/drain Hastelloy C head with side vent/drain 51452864-140 51452864-142 Monel head without side vent/drain Monel head with side vent/drain 51452864-150 51452864-152 Carbon steel head (nickel plated) without side vent/drain Carbon steel head (nickel plated) with side vent/drain ··································· ··································· ··································· ··································· ··································· ··································· Quantity Per Unit Each Process head Assembly Kit includes: Pipe Plug (See Note 1, 2.)····························································· Vent Plug (See Note 1.)································································ Vent Bushing (See Note 1.)·························································· Process Head ·············································································· Gasket (PTFE), Process Head ···················································· Gasket (PTFE), Flange Adapter··················································· NOTE 1 : This item is made of the same material as the Process Heads, except for Kits with carbon steel Process Heads, which include stainless steel Pipe Plug, Vent Plug, and Vent Bushing. NOTE 2: The Kit for Process Heads without side vent/drain does not include Pipe Plugs (K1). 2 1 1 1 1 1 Table 5 Pressure Specification and Ratings Summary Comparisons Transmitter Model Upper Range Limit Maximum Allowable Working Pressure (Note 1) Overpressure Rating (Note 1) Previous New Design Previous New Design STD110 10 inches H2O (25 mbar) 50 psi (3.5 bar) (Same as previous) 50 psi (3.5 bar) (Same as previous) STD120, STD924 400 inches H2O (1 bar) 3000 psi (207 bar) 4500 psi (310 bar) 3000 psi (207 bar) 4500 psi (310 bar) STD125 600 inches H2O (1.5 bar) " " " " STD130, STD930 100 psi (7 bar) " " " " STD170 3000 psi (207 bar) " " '" " Note 1 Maximum Allowable Working Pressure and Overpressure Rating may vary with materials of construction and with process temperature. For more specific information, refer to the appropriate Specification and Model Selection Guide. In transmitters with Graphite Gaskets, rating of 50 psi remains unchanged while ratings of 4500 psi are reduced to 3625 psi (250 bar). Flange Adapters with Graphite Gaskets have a 3000 psi rating. Intentionally blank 34-ST-99-37 10/04 ST 3000 Smart Pressure Transmitter, Release 300 with HART Communication Option Overview Addendum (to User Manual 34-ST-25-17) ATEX Directive 94/6/EC The ATEX Directive 94/6/EC is a European CE Mark directive concerning products that are designed for use in potentially explosive environments. This “New Approach” directive is based on, and is an expansion of, European Norms (EN, CENELEC standards). On June 30, 2003, the ATEX (ATmospheres EXplosibles) directive will replace directives currently in effect, and from that time, only products with the ATEX certification and with ATEX labeling will be approved for free movement in the EU (European Union) and EFTA (European Free Trade Association) countries. As defined in the directive, “free movement” refers to: − placing a product on the market, and/or − placing a product into service. The ATEX Directive 94/6/EC is a living (set of) document(s), subject to further change and refinement, whose details are beyond the scope of this addendum. Further information can be obtained in the Official Journal of the European Communities No L100/1, and in related publications such as Guidelines on the Application of Directive 94/9/EC. Both of these items are available at: http://europa.eu.int/comm/enterprise/atex/index.htm Products that have been previously certified under the EN and CENELEC European Norms, and which comply fully with all standards in the New Approach directive have, by application, received certification under ATEX Directive 94/6/EC. The Honeywell ST3000 Smart Pressure Transmitter is now ATEX certified, and all units manufactured currently and in the future will include labeling that includes all markings required under the ATEX directive. Inclusions To ensure that all required information will be available to the user, the following items are included with this Addendum for reference: 1. Declaration of Conformity – ATEX CE0344 (Honeywell document number 51452504 Revision B). 2. Certificate of Manufacturer – Ex II 3 G, EEx nA IIC ATEX CE (Honeywell document number 51452622 Revision C). Purpose and Content of this Addendum This Addendum includes information required under the ATEX Directive regarding: 1. The appearance and meaning of each certification mark (CE Mark) that appears on the label(s) affixed to the product. 2. Instructions for installation and use of the product. Installation information is given in 34-ST-33-39C - ST 3000 Smart Transmitter Release 300 and Smart Field Communicator Model STS103 Installation Guide Information required for use of this product, and additional installation information, is included in: 34-ST-25-17 - ST 3000 Smart Pressure Transmitter Release 300 with HART Communication Option User Manual of which this Addendum is a part. Details regarding certification marks that appear in labeling for this product are given in this addendum. Attention The publications cited above and the functioning and construction (except for labeling) of the devices described therein are essentially unchanged. The purpose of this addendum is to provide details the purpose and appearance of the labels attached to each device under ATEX Directive 94/6/EC. Attention Before installing the equipment in a potentially explosive atmosphere, please read the information provided in this Addendum, which supports the ATEX certifications for this product. CE Conformity The ST 3000 Smart Pressure Transmitter is in conformity with the protection requirements of the following European Council Directives: 94/9/EC, the Explosive Atmospheres (ATEX) Directive, 89/336/EEC, the Electromagnetic Compatibility (EMC) Directive, and the Pressure Equipment (PED) directive. In conformity with the ATEX directive, the CE mark on the certification nameplate includes the Notified Body identification number 0344 (KEMA 01ATEXQ3199) adjacent to the EC Type Examination Certificate number. In conformity with the Pressure Equipment Directive, models rated greater than 200 bar (2,900 psi) have an additional CE mark applied to the meter body data plate in accordance with 97/23/EC, Article 15. Models rated at less than 200 bar have no CE mark on the meter body data plate per 97/23/EC, Article 3, Section 3. Deviation from the installation conditions in this manual may invalidate this product’s conformity with the Explosive Atmospheres, Pressure Equipment, and EMC Directives. Conformity of this product with any other “CE Mark” Directive(s) shall not be assumed. Marking, ATEX Directive Honeywell’s Model ST 3000 Smart Pressure Transmitter, with the following nameplates attached, has been certified to comply with Directive 94/9/EC of the European Parliament and the Council as published in the Official Journal of the European Communities No. L 100/1 on 19-April-1994. The following information is provided as part of the labeling of the transmitter: Apparatus Marked with Multiple Types of Protection • Name and Address of the manufacturer: Honeywell, Phoenix, AZ 85053 USA. • Notified Body identification: KEMA Quality B.V., Arnhem, the Netherlands • For complete model number, see the Model Selection Guide for the particular model of pressure transmitter. • The serial number of the transmitter is located on the Meter Body data-plate. The first two digits of the serial number identify the year (02) and the second two digits identify the week of the year (23); for example, 0223xxxxxxxx indicates that the product was manufactured in 2002, in the 23 rd week. The user must determine the type of protection required for installation the equipment. The user shall then check the box [D] adjacent to the type of protection used on the equipment certification nameplate. Once a type of protection has been checked on the nameplate, the equipment shall not then be reinstalled using any of the other certification types. Nameplate 51452477-001, ia, 4-20 mA / HART, is mounted on the enclosure. The following is a representation of this nameplate: Nameplate 51452475-001, d, 4-20 mA / HART, is mounted on the enclosure. The following is a representation of this nameplate: Nameplate 51452619-001, nA, 4-20 mA / HART, is mounted on the enclosure. The following is a representation of this nameplate: Nameplate 50003886-001, 4-20 mA / HART, multiple certification nameplate. The following is a representation of this nameplate: Specific Parameters for Intrinsic Safety Field wiring terminals, (+ , –): Ui = 30 V, Ii = 100 mA, Pi = 1.2 W Without local analog meter, ME: Ci = 4.2 nF, Ri = 0, Li = 0 With local analog meter, ME: Ci = 4.2 nF, Ri = 0, Li = 150 µH With local smart digital meter, SM: Ci = 4.2 nF, Ri = 0, Li = 0 Special conditions for safe use, The pressure transmitter is an intrinsically safe apparatus that can be installed in potentially explosive atmospheres. Intrinsic Safety (X) The power terminals (+, -) must be connected only to a certified associated intrinsically safe apparatus. The electrical parameters (U, I, and P) of the associated apparatus connected to the power terminals (+, -) must not exceed the following values: Ui ≤ 30V Ii ≤ 100 mA Pi ≤ 1,2 W Ambient temperature: -50ºC to 93ºC NOTE: -50ºC to 93ºC is the certification and “Operative Limits” for the product family. Refer to individual Specification Sheets for the standard “Rated Condition” ambient limits for a particular model that, as shown on the data-plate and certification nameplate, may be less than the certification limits. Temperature classifications: IS (ia) 4 – 20 mA / HART Flameproof (d) T4 up to Ta ≤ 93º T5 up to Ta ≤ 93ºC T5 up to Ta ≤ 63ºC T6 up to Ta ≤ 78ºC T6 up to Ta ≤ 48ºC Enclosure classification: IP 66/67, Type 4X Specific Parameters for Flameproof Installation Power supply to field wiring terminals, (+, –): Ucc ≤ 42 V Output Signal: 4–20 mA / HART Special conditions for safe use, Flameproof Installation Specific Parameters for Non-Sparking Zone 2 Installtion (Honeywell certified) Ambient operating temperature: -50 to 93ºC NOTE: -50ºC to 93ºC is the certification and “Operative Limits” for the product family. Refer to individual Specification Sheets for the standard “Rated Condition” ambient limits for a particular model that, as shown on the data-plate and certification nameplate, may be less than the certification limits. Supply Voltage: 11-42 Vdc Supply Current: 23 mA Ambient Temperate Limits: -50oC to 93oC Temperature Classification: T6 at Ta ≤ 78oC T5 at Ta ≤ 93oC Special Condition for Safe Use, Non-Sparking Zone 2 Installation (Honeywell certified) • The installation of this equipment in Zone 2 hazardous areas must comply with VDE specification 0165, IEC 60079-14, EN 50021 and/or valid national standards for installation and operation. • Before commissioning of this equipment, it must be verified that the power supply voltage cannot exceed the 42 Vdc maximum for 4-20 mA analog and DE equipment. • The electronic assemblies in these units are non-repairable items and if faulty must be replaced. The electrical power supply must be switched off before any replacement and during any time that the wiring terminations are being connected or disconnected. 51452504, Revision B DECLARATION OF CONFORMITY ATEX 0344 We declare under our sole responsibility that the following products, ST 3000 Smart Pressure Transmitters, Series 100 and 900, Release 300 (per attached list) to which this declaration relates, are in conformity with the protection requirements of Council Directive: 94/9/EC (ATEX Directive) on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres, and 89/336/EEC (EMC Directive) as amended by 92/31/EEC and 93/68/EEC on the approximation of the laws of the Member States relating to Electromagnetic Compatibility. The models covered by this Declaration and evidence of conformity with the ATEX Directive are shown on the attached list. Conformity to the ATEX Directive is in accordance with the following European standards. EN 50014-1997 Electrical Apparatus for Potentially Explosive Atmospheres - General Requirements EN 50018-2000 Electrical Apparatus for Potentially Explosive Atmospheres - Flameproof Enclosure “d” EN 50020-1994 Electrical Apparatus for Potentially Explosive Atmospheres - Intrinsic Safety "i" EN 50284-1999 Special Requirements for Construction, Test and Marking of Electrical Apparatus of Equipment Group II, Category 1 G Notified Bodies: Manufacturing Locations: EC Type Examination Certificates LCIE – Groupe Bureau Veritas – 0081 33, Avenue du Général Leclerc 92260 Fontenay-aux-Rose France Production Quality Assurance Notification KEMA Quality B. V. – 0344 Utrechtseweg 310 6812 AR Arnhem The Netherlands Honeywell Industrial Solutions Industrial Solutions 2500 West Union Hills Drive Phoenix, Arizona 85027 USA The authorized signatory to this declaration, on behalf of the manufacturer, and the Responsible Person is identified below. Honeywell International Inc. Industrial Measurement & Control 1100 Virginia Drive Fort Washington, PA 19034 USA Frederick M. Kent Standards & Approvals Engineer, (ATEX Authorized Person) Issue Date: 18 August, 2002 ST3000, R300 Pressure Transmitters Certificate LCIE 02 ATEX 6099 LCIE 02 ATEX 6100X LCIE 02 ATEX 6101X LCIE 03 ATEX 6175X Model STA122 STA140 STD110 STD120 STD125 STD130 STD170 STF128 STF12F STF132 STF13F STF14F STF14T STG140 STG14L STG14T STG170 STG17L STG180 STG18L STR12D STR13D STR14A STR14G STR17G STA922 STA940 STD924 STD930 STD974 STF904 STF924 STF92F STF932 STF93F STG19L STG93P STG944 STG94L STG974 STG97L STG98L STG99L STR93D STR94G Series 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 Protection Ex II 2 G, EEx d IIC, T6 or T5 Ex II 2 G, EEx ia IIC, T6 to T4 Ex II 1 G, EEx ia IIC, T6 to T4 Ex II 1 G, EEx ia IIC, T6 to T4 Model ST……-3D ST……-3S ST…-HC…-3S ST…-HC…-3S Description 4-20 mA / DE / HART / Fieldbus 4-20 mA / DE 4-20 mA / HART Foundation TM Fieldbus Description Absolute Pressure Transmitter Absolute Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter High Temperature Flange Mounted Pressure Transmitter Gauge Pressure Transmitter Gauge Pressure Transmitter High Temperature Gauge Pressure Transmitter Gauge Pressure Transmitter Gauge Pressure Transmitter Gauge Pressure Transmitter Gauge Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Gauge and Absolute Pressure Transmitter Gauge and Absolute Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter High Pressure Gauge Transmitter Flush Mount Gauge Pressure Transmitter Gauge and Absolute Pressure Transmitter In-Line Gauge Pressure Transmitter Gauge and Absolute Pressure Transmitter In-Line Gauge Pressure Transmitter In-Line Gauge Pressure Transmitter High Pressure Gauge Transmitter Remote Diaphragm Seal Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Factory Phoenix Phoenix Phoenix Phoenix 51452622, Revision C Certificate of Manufacturer II 3 G EEx nA IIC ATEX This certificate applies to the following equipment: ST 3000 Smart Pressure Transmitters, Series 100 and 900, Release 100 and 900, 4-20 mA, DE, HART, and FOUNDATIONTM Fieldbus (per attached list) This equipment has no arcing or sparking parts and no ignition-capable hot surfaces, and therefore conforms to Clause 6.3.1.3 of VDE 0165/2.91, IEC 60079-14, and EN 50021 for operation in Zone 2 hazardous areas providing that the following conditions are observed. The equipment contains no intrinsically safe or energy-limiting components. The listed equipment are 2-wire devices that receive their power and signal carrier from the same 420 mA signal current or Fieldbus supply. In normal operation, the maximum current supply is 23 mA for ≤ 4-20 mA analog, DE or HART, and ≤ 260 mA for Fieldbus. Conditions for the application of the above equipment in Zone 2 hazardous areas: The installation of this equipment in Zone 2 hazardous areas must comply with VDE specification 0165, IEC 60079-14, EN 50021 and/or valid national standards for installation and operation. Before commissioning this equipment, it must be verified that the power supply voltage cannot exceed the 42 Vdc maximum for 4-20 mA analog, DE and HART equipment, and 24 Vdc for Fieldbus equipment. The electronic assemblies in these units are non-repairable items and if faulty, must be replaced. The electrical power supply must be switched off before any replacement and during any time that the wiring terminations are being connected or disconnected. The technical data supplied by the manufacturer must be adhered to. Specifications for Use in Zone 2 4-20 mA / DE / HART Fieldbus Supply Voltage: 11 – 42 Vdc 10 – 24 Vdc Supply Current: 23 mA 260 mA Ambient temperature limits: –50 to 93ºC Temperature Classification: Manufacturing Location: T6 at Ta ≤ 78ºC T5 at Ta ≤ 93ºC Honeywell Process Solutions 2500 West Union Hills Drive Phoenix, Arizona 85027 USA Honeywell International Inc. Industrial Measurement & Control 1100 Virginia Drive Fort Washington, PA 19034 USA Frederick M. Kent Standards & Approvals Engineer, (ATEX Authorized Person) Issue Date: 25 June 2004 ST3000, R300 Pressure Transmitters Model STA122 STA140 STD110 STD120 STD125 STD130 STD170 STF128 STF12F STF132 STF13F STF14F STF14T STG140 STG14L STG14T STG170 STG17L STG180 STG18L STR12D STR13D STR14A STR14G STR17G STA922 STA940 STD924 STD930 STD974 STF904 STF924 STF92F STF932 STF93F STG19L STG93P STG944 STG94L STG974 STG97L STG98L STG99L STR93D STR94G Series 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 Description Absolute Pressure Transmitter Absolute Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter High Temperature Pressure Transmitter Gage Pressure Transmitter Gage Pressure Transmitter High Temperature Pressure Transmitter Gage Pressure Transmitter Gage Pressure Transmitter Gage Pressure Transmitter Gage Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Gage and Absolute Pressure Transmitter Gage and Absolute Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter Flange Mounted Liquid Level Transmitter High Pressure Gauge Transmitter Flush Mount Gage Pressure Transmitter Gauge and Absolute Pressure Transmitter In-Line Gage Pressure Transmitter Gauge and Absolute Pressure Transmitter In-Line Gauge Pressure Transmitter In-Line Gauge Pressure Transmitter High Pressure Gauge Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Remote Diaphragm Seal Pressure Transmitter Industrial Measurement and Control Honeywell International, Inc. 2500 W. Union Hill Drive Phoenix, Arizona 85027