floor deck catalog
Transcription
floor deck catalog
TABLE OF CONTENTS FLOOR DECK CATALOG COMPOSITE DECK AND NON-COMPOSITE DECK FOR FLOOR AND ROOF DECK APPLICATIONS VERSION 1.0 TABLE OF CONTENTS General Benefits of Composite Steel Deck ASC Steel Deck has a firm understanding of the benefits composite steel deck provides in building construction. The strength of composite steel deck slab, relative to its light weight, makes it the clear building material of choice when compared to the alternative cast-in-place concrete approach. Composite steel deck serves a dual function as it provides both concrete reinforcement and a concrete form, while serving as a working platform through the erection process. Moreover, projects designed with a composite deck system simply go up faster. The versatility, recyclable content, structural performance, and ease of installation makes steel deck the ideal building material for building owners, architects, and engineers. Aesthetic Value of Steel Deck ASC Steel Deck products offer the beauty of exposed steel as an added benefit to the structural performance required of building designs. Our new Smooth Series™ cellular deck offers a blemish free beam-to-pan rivet attachment, providing a clean surface ideal for an exposed steel design. When noise reduction is a necessity, ASC Steel Deck's Acustadek® panels offer acoustical noise reduction capabilities with aesthetic features which complement its use on exposed applications. Acustadek® is generally preferred in high noise areas such as airports, schools, gymnasiums, and concert halls. Offering a Full Line of Steel Deck Products ASC Steel Deck is the only steel deck manufacturer on the West Coast which offers a full line of light-gage structural and deep deck products. From the standard 1½” to 3” roof and composite floor deck, to concrete form deck, to long spanning deep deck profiles, ASC Steel Deck’s extensive product offer meets the needs of the most complex conditions and demands for structural performance and design. Most of our floor and roof deck products are offered in a variety of perforated acoustical options. For structural and acoustical performance information on these products, refer to the Acustadek® section of this catalog and our Roof Deck Catalog. TABLE OF CONTENTS Your Feedback is Welcome Leading the way in steel deck innovation is dependent upon your feedback. We invite architects, engineers, building owners, and all members of the building design and construction industry to reach out to ASC Steel Deck with any comments, suggestions, or needs for a profile we currently do not offer Email us at info@ascsd.com 5.0 N PANELS 1.1 Panel Features and Benefits . . . . . . . . . . . . . . . . . . . . . . 2-5 1.2 Product Offer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9 1.3 Product Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.4 Fire Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-21 1.5 Steel Deck Section Properties . . . . . . . . . . . . . . . . . . . 22-23 1.6 Web Crippling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25 1.7 Steel Deck at Concrete Form . . . . . . . . . . . . . . . . . . . . 26-27 1.8 Composite Deck-Slab Design . . . . . . . . . . . . . . . . . . . 28-30 1.9 Non-Composite Deck-Slab Design . . . . . . . . . . . . . . . . . 31 1.10 Penetrations and Openings . . . . . . . . . . . . . . . . . . . . . 32-35 1.11 Composite and Non-Composite Diaphragm Shear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 1.12 Composite Deck-Slab Tables . . . . . . . . . . . . . . . . . . . 38-39 1.13 Support Fastening . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-45 1.14 Side Seam Fastening . . . . . . . . . . . . . . . . . . . . . . . . . . 46-47 1.15 Edge Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-49 1.16 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 1.17 Typical Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51-54 1.18 Composite Deck-Slab Tables General Requirements . . . . . . . . . . . . . . . . . . . 55-57 5.1 5.2 5.3 5.4 3WxH-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . 58 3WxHF-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . 59 3WxHF-36 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 60-61 3WxH-36 Composite Deck-Slab . . . . . . . . . . . . . . . . . . 62-81 3.1 3.2 3.3 3.4 2WH-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 82 2WHF-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 83 2WHF-36 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . . 84-85 2WH-36 Composite Deck-Slab . . . . . . . . . . . . . . . . . . 86-107 4.0 B PANELS BH-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . . 108 BHF-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 109 BHF-36 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 110-112 BH-36 Composite Deck-Slab . . . . . . . . . . . . . . . . . . 113-122 7.0 D PANELS (FORM DECK) 7.1 7.2 7.3 7.4 7.5 7.6 4.5D-12 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 148 4.5D-12 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 149 4.5D-12 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 150-151 4.5DF-24 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . 152 4.5DF-24 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . 153-155 4.5DF-24 Shoring Tables . . . . . . . . . . . . . . . . . . . . . 156-157 7.7 6D-12 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . . . 158 7.8 6D-12 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 7.9 6D-12 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . . . 160-161 7.10 6DF-24 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 162 7.11 6DF-24 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . 163-165 7.12 6DF-24 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . . 166-167 7.13 7.5D-12 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 168 7.14 7.5D-12 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 169 7.15 7.5D-12 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 170-171 7.16 7.5DF-24 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . 172 7.17 7.5DF-24 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . 173-175 7.18 7.5DF-24 Shoring Tables . . . . . . . . . . . . . . . . . . . . . 176-177 8.0 ACUSTADEK® 8.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 8.2Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 D PANEL 4.1 4.2 4.3 4.4 6.4 C1.4-32 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 144 6.5 C1.4-32 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 145 6.6 C1.4-32 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 146-147 C PANELS 3.0 2W PANELS 6.1 C0.9-32 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 140 6.2 C0.9-32 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 141 6.3 C0.9-32 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 142-143 N PANELS 2.1 2.2 2.3 2.4 6.0 C PANELS (FORM DECK - CF7⁄8 and CF13⁄8) B PANELS 2.0 3Wx PANELS NH-32 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . . 124 NHF-32 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 125 NHF-32 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 126-127 NH-32 Composite Deck-Slab . . . . . . . . . . . . . . . . . . 128-138 2W PANELS 1.0 GENERAL INFORMATION 3W PANELS ASC Steel Deck is leading the way in innovation with ongoing testing of our profiles. As a result, our printed catalogs may not contain/reflect the latest test results and values of our products. For the most current load tables, refer to our catalog online at www.ascsd.com. GENERAL INFORMATION Table of Contents METRIC CONVERSION CHART . . . . . . . . . . . . . . . . . 180 ACUSTADEK® Hilti is a registered trademark of Hilti Corp., LI- 9494 Schaan, Principality of Liechtenstein PNEUTEK is a registered trademark of Pneutek, 17 Friars Drive Hudson, NH www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 1 TABLE OF CONTENTS 1.1 Panel Features and Benefits 3WxH-36 Hi Form® 3WxHF-36 Hi Form® Composite deck Composite deck 3 inch deep, 36 inch coverage, 3 inch deep, 36 inch coverage, 10 foot to 14 foot Optimal Span Range 11 foot to 15 foot Optimal Span Range ® No Acustadek Options Proven for 10 to 14 foot span conditions Pan Perforated Acustadek® Option (Available with Smooth Series™ rivet attachments or welded) Meets SDI 3x12 inch standard profile requirements Aesthetic flat pan underside Longer unshored spans than 2WH-36 and BH-36 Meets SDI 3x12 inch standard profile requirements Meets industry standard 4.5” min. flute width Longer unshored spans than 2WH-36 and BH-36 Compatible with all standard concrete anchors Meets industry standard 4.5” min. flute width Compatible with all standard concrete anchors 2WH-36 Hi Form® 2WHF-36 Hi Form® Composite deck Composite deck 2 inch nominal depth, 36 inch coverage 2 inch nominal depth, 36 inch coverage 7 foot to 12 foot Optimal Span Range 9 foot to 13 foot Optimal Span Range ® No Acustadek Option Least steel weight per square foot floor deck Meets SDI 2x12 inch standard profile requirements Pan Perforated Acustadek® Option (Available with Smooth Series™ rivet attachments or welded) Aesthetic flat pan underside Reduced composite slab depth compared to 3WxH-36 and NH-32 Meets SDI 2x12 inch standard profile requirements BH-36 Hi Form® BHF-36 Hi Form® Composite deck Composite deck 1 ⁄2 inch depth, 36 inch coverage 11⁄2 inch depth, 36 inch coverage 7 foot to 10 foot Optimal Span Range 7 foot to 12 foot Optimal Span Range No Acustadek® Option Pan Perforated Acustadek® Option (Available with Smooth Series™ rivet attachments or welded) 1 Lowest composite deck-slab weight per square foot for the specified concrete thickness above the deck Meets SDI 1.5WR (wide rib) standard profile requirements 2 Reduced composite slab depth compared to 3WxHF-36 and NHF-32 Aesthetic flat pan underside Meets SDI 1.5WR standard profile requirements Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS NHF-32 Hi Form® Composite deck Composite deck 3 inch depth, 32 inch coverage 3 inch depth, 32 inch coverage 10 foot to 15 foot Optimal Span Range 11 foot to 15 foot Optimal Span Range ® 3W PANELS NH-32 Hi Form® Excellent alternate to SDI DR (deep rib) profile Lower composite deck-slab weight than 3WxH-36 for the specified concrete thickness 8 inch on center low flute spacing to allow for bearing wall studs to be at 16 inches on center 2W PANELS Pan Perforated Acustadek® Option (Available with Smooth Series™ rivet attachments or welded) No Acustadek Options Longest unshored spans Aesthetic flat pan underside Excellent alternate to SDI DR (deep rib) profile 8 inch on center low flute spacing to allow for bearing wall studs to be at 16 inches on center Non-composite deck 7 ⁄8 inch depth, 32 inch coverage 13⁄8 inch depth, 32 inch coverage 2 foot to 7 foot Span Range 4 foot to 9 foot Span Range No Acustadek® Options No Acustadek® Options Good for short span conditions Good for intermediate span conditions For use when metal deck is used as a leave in place form For use when metal deck is used as a leave in place form C PANELS Non-composite deck N PANELS C1.4-32 (CF13⁄8) B PANELS C0.9-32 (CF7⁄8) GENERAL INFORMATION Panel Features and Benefits 1.1 D PANEL ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 3 TABLE OF CONTENTS 1.1 Panel Features and Benefits 4.5D-12 4.5DF-24 Non-composite deck Non-composite deck 4 ⁄2 inch depth, 12 inch coverage 41⁄2 inch depth, 24 inch coverage 12 foot to 21 foot Span Range 15 foot to 21 foot Span Range 1 ® No Acustadek Option Pan Perforated Acustadek® Option Allows for longest unshored spans Aesthetic flat pan underside For use when metal deck is used as a leave in place form Allows for longer unshored span when metal deck is used as a leave in place form Longer unshored span than non-cellular profile For use when metal deck is used as a leave in place form 6D-12 6DF-24 Non-composite deck Non-composite deck 6 inch depth, 12 inch coverage 6 inch depth, 24 inch coverage 14 foot to 25 foot Span Range 15 foot to 25 foot Span Range No Acustadek® Option Pan Perforated Acustadek® Option Allows for longest unshored spans Aesthetic flat pan underside For use when metal deck is used as a leave in place form Allows for longer unshored span when metal deck is used as a leave in place form Longer unshored span than non-cellular profile For use when metal deck is used as a leave in place form 7.5D-12 7.5DF-24 Non-composite deck Non-composite deck 7 ⁄2 inch depth, 12 inch coverage 71⁄2 inch depth, 24 inch coverage 16 foot to 26 foot Span Range 16 foot to 27 foot Span Range 1 ® No Acustadek Option Pan Perforated Acustadek® Option Allows for longest unshored spans Aesthetic flat pan underside For use when metal deck is used as a leave in place form Allows for longer unshored span when metal deck is used as a leave in place form Longer unshored span than non-cellular profile For use when metal deck is used as a leave in place form 4 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Economical Selection Guide based on Recommended Unshored Spans Product 2 4 6 8 10 12 14 16 18 20 22 24 26 GENERAL INFORMATION Panel Features and Benefits 1.1 28 3W PANELS C0.9-32 C1.4-32 BH-36 2W PANELS 2WH-36 3WxH-36 NH-32 B PANELS BHF-36 2WHF-36 3WxHF-36 NHF-32 N PANELS 4.5D-12 6D-12 7.5D-12 C PANELS 4.5DF-24 6DF-24 7.5DF-24 D PANEL Box outlines the range of unshored spans from the recommended unshored span range Gray cells are based on 1 hour and 2 hour fire ratings with 20 and 18 gauge decks ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 5 TABLE OF CONTENTS 1.2 Product Offer ASC Steel Deck offers a robust selection of products. Our lightweight composite and non composite steel deck profiles have depths that range from 7⁄8” to 71⁄2”. Panel lengths range from 3’-6” to 45’. Steel deck panels are supplied with both galvanized and painted finishes to meet an array of project finish requirements. Product Description To assist designers with specifying the correct steel deck profile, see figure 1.2.3 which details how to specify the intended product. Following these guidelines will help to eliminate requests for information and change orders due to insufficient product descriptions in the plans and specifications. Designers can be assured that the product delivered is the product intended. Simply specify the gage, panel profile, panel coverage, metallic/paint coating, and any modifiers appropriate for the desired product. Deck Panel Lengths All ASC Steel Deck products are manufactured to the specified length for the project. The following table summarizes the minimum and maximum lengths which can be manufactured for each profile. Figure 1.2.1: MANUFACTURED PANEL LENGTHS Profile Noncellular Cellular Factory Cut Length Minimum Maximum BH-36, NH-32, 2WH-36, 3WxH-36 3’-6” 45’-0” C0.9-32 & C1.4-32 4’-0” 45’-0” 4.5D-12, 6D-12, 7.5D-12 6’-0” 32’-0” BHF-36, NHF-32, 2WHF-36, 3WxHF-36 5’-0” 40’-0” 4.5DF-24, 6DF-24, 7.5DF-24 6’-0” 32’-0” Tolerances ASC Steel Deck manufactures to industry standard tolerances. The tolerances are summarized as follows. Figure 1.2.2: PANEL TOLERANCES Length ±1/2” Coverage Width -3/8” +3/4” Sweep 1/4” in 10’ length Square 1/8” per foot width Height ±1/16” Finish Options ASC Steel Deck offers several finish options that are appropriate for a variety of applications. Our standard G60 galvanized finish is suitable for most applications, offering excellent corrosion protection and compatibility with fire proofing when used in UL fire rated assemblies. We also offer Prime Shield®, an economical prime paint system over bare cold rolled steel. Prime Shield® offers the steel limited interim protection from rusting during transport and erection before the concrete topping is applied. Prime Shield® should not be used in high humidity or corrosive environments. Prime paint over galvanized steel deck can also be specified to obtain the benefit of the corrosion protection of galvanized steel deck with a factory applied prime paint substrate. 6 Galvanized ASC Steel Deck offers steel deck products that are galvanized in accordance with ASTM A653. The standard galvanized coating is G60 (0.6 ounce per square foot). G-90 (0.9 ounce per square foot) is recommended for high humidity and corrosive conditions. G-40 (0.4 ounce per square foot) may also be specified for greater economy. Heavier galvanized finishes than G-90 can be specified for more severe environmental conditions and exposures. Inquire for product availability and minimum order sizes for G-40 or galvanizing heavier than G-90. All ASC Steel Deck galvanized decks are manufactured from chemically treated steel coil in accordance with ASTM A653. Chemical treatment is often referred to as passivation. The chemical treatment protects the galvanized steel from developing white rust during storage and transport of both coil and finished product. Some field-applied paint systems may not be compatible with the chemical treatment. The paint manufacture should be consulted to determine how the deck should be prepared prior to painting. ASC Steel Deck is not responsible for the adhesion of field applied primers and paints. Galvanized with Prime Paint ASC Steel Deck offers all of its standard galvanized options with factory applied prime paint on the underside of the deck. The prime paint is available in standard gray. White primer is also available. The standard 0.3mil waterbased gray acrylic primer has been specially developed to provide superior adhesion to the galvanized steel deck and is suitable for use in many UL fire rated assemblies. Factory applied primer is an impermanent interim coating that is intended to have finish paint applied after the deck is installed. The galvanized with prime paint option may eliminate the need for any special surface preparation for field applied paint applications which is often a requirement for chemically treated bare galvanized steel deck panels. ASC Steel Deck is not responsible for the adhesion of paint systems applied in the field. Cellular deck is offered with a galvanized steel pan or a prime paint over galvanized steel pan. This 0.3mil gray primer is applied to the underside of the pan prior to resistance welding or riveting the cellular deck beam to the pan. Our new Smooth Series™ rivet attachment is flush with the exposed bottom surface, omitting visible “bumps” and burn marks, eliminating the cost of touch-ups associated with resistance welded deck products. Resistance welded deck, the current industry standard, leaves burn marks on the pan which generally require cleaning and touch-up prior to the application of a finish paint system being applied. Touching up the burn marks is generally much more cost effective than preparing an unpainted, chemically treated surface for the application of a field primer. The prime painted galvanized pan provides a good substrate for the application of most field-applied paint systems. ASC Steel Deck is not responsible for the adhesion of paint systems applied in the field. Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS DG Specify Required Gage(s) of Deck 22 191 DG: DeltaGrip standing seam side lap interlock 182 162 Omit: Nonembossed smooth deck (Roof) H: Embossed HiForm composite deck (Floor) 20/203 20/183 18/203 18/183 18/163 16/20 Fr: Cellular (Smooth Series™ Rivet Attachment) N: Nestable side lap, (B and N Deck only) S: Standing seam screwable side lap (2WHS-36 only) 2 D is only available in these gages 3 DF is only available in these gages AT: Acustadek® total perforation for use with noncellularstandard or DeltaGrip, DG, profiles only A: Acustadek® pan perforation for use with cellular profile modifier, F, only Mo di fi er s de pa in t Sp ec ial Si Si To p Bo tto m de P ain t Co at in g( s) ic ta ll Me G60: Galvanized G90: Galvanized G60/G60: Galvanized G90/G90: Galvanized Note: Inquire for other galvanized coating weights None: No primer Omit: None Prime Shield®: Gray primer on bare steel or GO1 galvanized NS: No Swage, B-36 only Gray: Primer over galvanized (Available for cellular deck) Weldable Primer: (Only available for cellular decks span underside only) White: Primer over galvanized Cellular Deck Cellular deck is a good choice when a flat appearance on the underside of steel deck is desired. Cellular deck is manufactured from a top fluted section of steel deck referred to as the beam and a flat bottom section referred to as the pan. The male and female side seam interlock is formed on the edges of the pan. V: Venting (non-cellular only) Not Applicable Roof Coverage B 36 inches N 32 inches 2W 36 inches 3Wx 36 inches C0.9-32 Not Applicable 32 inches C1.4-32 CP-32 32 inches 4.5D 12 inches 4.5DF 24 inches 6D 12 inches 6DF 24 inches 7.5D 12 inches 7.5DF 24 inches The welded method offers resistance welds in accordance with UL 209. There is one row of resistance welds in each low flute of the beam. D PANEL Figure 1.2.5: SMOOTH SERIES™ RIVET ATTACHMENT (Pictured from topside) The new Smooth Series™ rivet attachment is flush with the exposed bottom surface, eliminating “bumps” and burn marks and the need for touch-ups in the field. Smooth Series rivets are available in galvanized and white finish, complementing our factory applied Prime Shield® primer gray and white finish cellular deck. The high quality rivet attachments are uniformly repeated along the deck profile. Composite and Non-Composite Deck Catalog • February 2016 7 ACUSTADEK® ASC Steel Deck may substitute ASTM A653 G01 galvanized steel deck for ASTM A1008. Figure 1.2.4: WELDED ATTACHMENT (Pictured from topside) C PANELS Prime Shield® Prime Shield® is prime painted cold-rolled, ASTM 10081, steel deck. The standard gray primer is applied to the underside of the steel deck (as compared to both sides for roof deck) leaving the top side bare for concrete adhesion. The formation of light rust on the top side of the deck prior to concrete placement is common and does not adversely impact the deck or composite deck-slab assembly. This primer is suitable for use in many UL fire rated assemblies. The prime paint is intended to be an impermanent interim coating to protect the bare cold-rolled steel, for a short period, from ordinary atmospheric conditions prior to weathertighting the building. Prime Shield® should receive a finish paint system if left exposed in the interior of a building. This 0.3mil water-based acrylic primer provides a good base for most field-applied paint systems. ASC Steel Deck is not responsible for the adhesion of paint systems applied in the field. www.ascsd.com Omit: Bare NonGalvanized Steel DECK PROFILE AND COVERAGE LIST Not Applicable 1 Gray / Gray N PANELS 2W & 3Wx only on special order er AW: Acustadek® web perforation for use with noncellularstandard or DeltaGrip, DG, profiles only Omit: Standard profiles non-cellular with standard standing seam side lap interlock Non-Composite 1 G60/G60 Omit: Standard profiles without Acustadek® perforations See Deck Profiles and Coverage List 3 16/163 Mo di fi ra A B PANELS 20/163 Op tio na l Co ve ne l 36 F: Cellular (Welded) 142 16/18 _ 2W PANELS Omit: Standard standing seam side lap interlock 202 F Pa Hi H See Deck Profiles and Coverage List 211 ge Mo di Co fie nfi r gu ra tio n Mo di e ofi l B 3W PANELS 18/20 Fo rm Pr ne l Pa De lta Gr ip Ga ge (s ) Mo di fi er fie r Figure 1.2.3: PRODUCT OFFER DESCRIPTION GENERAL INFORMATION Product Offer 1.2 TABLE OF CONTENTS 1.2 Product Offer This product should not be used in floor assemblies where spray on fire proofing is to be applied to the bottom surface of the deck. Cellular deck beam and pan may be manufactured out of the same gage or out of different gages. The following shows how to correctly specify the desired beam and pan gage combination. Specify Cellular Deck Gage “xx/yy” • The first (xx) is the gage of the beam (top fluted section) • The second number (yy) is the gage of the pan (the bottom flat section with the side seam) Venting Some materials in building assemblies, including composite or non composite steel deck, may require the deck to be vented. Venting does not impact structural performance of steel deck and has no bearing on fire ratings. Venting does not influence the rate at which the concrete moisture content drops during curing of the slab on the deck. Some materials that are bonded by adhesives to the surface of the concrete slab on the composite deck may be sensitive to the moisture content of the concrete. Venting is sometimes specified, with the intent of creating a route for moisture to escape from the bottom of the concrete through the steel deck vents. Research performed by the Expanded Shale Clay and Slate Institute, however, demonstrated that venting has no bearing on how quickly the moisture content of concrete on steel deck decreases (concrete drying time)2. Deck should not be specified as vented when it is not required by another materials' performance specification. The drawback of venting deck is that when concrete is poured, the slurry drips through the vent tabs creating debris on the surface below. Cleaning up the slurry or protecting the surfaces underneath with plastic sheets adds cost to the project without providing any added value to the owner when venting is not required. The requirement for venting the deck should be clearly indicated in the specifications and be clearly stated in the deck schedule on the structural drawings to avoid confusion. Figure 1.2.7: 3WxH-36V WITH VENTING (Pictured from topside) Vent Tabs All ASC Steel Deck composite decks including; BH, NH, 2WH, and 3WxH deck, have upward protruding vent tabs which are factory punched in the low flutes of the steel deck when venting is specified. (See Figures 1.2.6, and 1.2.7) C0.932 and C1.4-32 do not have a venting option. CP-32 roof deck may be used as an alternate to C1.4-32 when venting is required. The CP-32 has embossments in the side lap that holds the side lap open creating a vent at each side. Die Set Ends (Swage) Die set ends allow for deck panels to be end lapped. This is not a common practice for composite deck but is common for roof decks. The die set swages the top flange and webs of the steel deck which allows the top sheet of end lapped deck to nest tightly over the bottom sheet. When deck is not die set, the installer may have to hammer the deck to get the ends to nest together tightly to ensure good quality connections. The die set ends are standard for BH-36 and NH-32 profiles. BH-36 is optionally available without die set ends. 2WH-36, 3WxH-36, Deep Deck, and cellular profiles are not end lapped and do not have die set ends. Figure 1.2.8 shows a die-set end on NH-32 deck. Note: 2. Craig, Peter A. (2011) Lightweight Concrete Drying Study. Chicago, IL: Expanded Shale Clay and Slate Institute Figure 1.2.6: BH-36V WITH VENTING (Pictured from underside) 8 Figure 1.2.8 N-32 WITH DIE-SET (Swage) Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS MALE SIDE SEAM 2nd RUN FEMALE SIDE SEAM END LAP Figure 1.2.9: DECK LAYOUT ACUSTADEK® Figure 1.2.11: TOPSIDE HANDLING MARKS www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 D PANEL Figure 1.2.10: UNDERSIDE HANDLING MARKS C PANELS The Fire Ratings table (See figure 1.4.1) offers a quick reference summary of design numbers, fire ratings, deck type, SFRM Spray Applied Fire Resistive material listings and more. The details of each design assembly are listed on the UL Online Certification Directory www.ul.com. N PANELS Underwriters Laboratories UL-Fire Ratings ASC Steel Deck products which bare the UL approved mark have been investigated for fire resistance. Underwriters Laboratories is an independent, product safety testing and certification organization. ASC Steel Deck has been evaluated for fire resistance per UL 263 Fire Tests of Building Construction and Materials. See UL directory for fire rated assemblies. B PANELS Exposed Deck ASC Steel Deck roof and floor deck products are designed to be structural components for steel framed structures. As part of the normal manufacturing, handling, and transport procedures, it is common for the panel bundles to exhibit some degree of incidental scratching and denting. The surface defects are typically superficial and do not impact the structural capacity of the deck. On projects where the deck will be exposed to view after installation, it may be desirable to minimize the occurrence of these marks. In these cases, it is important for the designer specifying and the customer or contractor ordering the deck to request that the product be manufactured, handled, and transported for "EXPOSED" installation. This will result in modified handling and loading procedures designed to minimize (not eliminate) typical scratching and denting. Figure 1.2.10 and 1.2.11 shows typical handling marks from forklifts or dunnage. IAPMO-ES ASC Steel Deck's composite and non-composite steel deck panels are independently evaluated for conformance with the IBC by IAPMO-ES. IAPMOES is accredited by the American Standards Institute (ANSI) per ISO/IEC Guide 65 General Requirements for Bodies Operating Product Certification Systems. LA City Research Reports (LARR) for ASC composite and non-composite steel decks are derived from IAPMO-ES reports. The technical evaluation for conformance with the IBC is made available to code officials, contractors, specifiers, architects, engineers, and others. IAMPO-ES reports provide evidence that ASC Steel Deck products meet the most rigorous standards and are compliant under current code requirements. 2W PANELS Die set ends affect detailing and layout of the steel deck. Deck is spread in the direction of the male leg of the side seam. This allows the next sheet’s female side seam to drop over the male side seam. The die set is on the left side relative to the direction of spreading deck. The next adjacent run of deck will be on the left side of the deck relative to the spreading direction to nest over the dies set ends. (See figure 1.2.9) ASC Steel Deck conducts extensive test and engineering programs with independent testing labs to ensure that our products comply with the stringent criteria of today’s building codes. The structural performance of our composite and non-composite steel deck products have been verified and evaluated by reputable evaluation agencies, such as the International Association of Plumbing and Mechanics Officials Uniform Evaluation Services (IAPMO-ES), Los Angeles City Research Reports (LARR), and Underwriters Laboratory (UL). 3W PANELS 1st RUN OF DECK DIE SET END GENERAL INFORMATION Product Approvals 1.3 9 TABLE OF CONTENTS 1.4 Fire Ratings Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE UL Design Number Unrestrained Assembly Rating8 Minimum Beam or Joist D216 W8x15, 10J3, 12K1, 20LH with a minimum of 13 lbs per foot weight 1, 1-1/2, 2, 3 D303 W8x28 1, 1-1/2, 2 Minimum Concrete Reinforcing hr Fire Proofing2 On Beam Deck 6x6 W1.4xW1.4 None (ceiling system below) none 6x6 10x10 SWG Mineral fiber board Mineral fiber board none D502 W8x28, 20" Joist Girders at 20plf, 12K1, LH Series joists 1-1/2, 2 6x6 W1.4xW1.4 none (ceiling system below) D703 W8x20 1, 1-1/2 6x6 W2.9xW2.9 SFRM SFRM D708 W10x17 1-1/2,3 6x6 W2.9xW2.9 SFRM SFRM D712 W8x24 1-1/2, 2 6x6, 10x10 SWG SFRM SFRM D722 W6x12 1, 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM D739 W8x28, W6x12,OWSJ, Cast in place concrete beams 1, 1-1/2, 2, 3, 4 6x6 W2.9xW2.9, Synthetic fibers SFRM SFRM D740 W10x15 1 6x6 10x10 SWG SFRM SFRM D743 W8x20, W8x28, W8x15, Cast in place concrete beams 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM D750 W8x21 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM D754 W8x28 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM D755 W8x24, W8x28, 10H3, 12J6 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM 10 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 3 1/2 147-153 NW 4 147-153 NW 2 4 1/2 147-153 NW 3 5 1/4 147-153 NW 3/4 or 1 2 1/2 107-113 LW 1 1/2 3 107-113 LW 2 3 1/4 107-113 LW 2 3 1/4 107-116 LW 3 4 3/16 107-113 LW 1 2 5/8 107-120 LW 2 3 1/2 114-120 LW 3 4 7/16 114-120 LW ✓ ✓ ✓ ✓ 1-1/2, 2 2 1/2 147-153 NW ✓ ✓ ✓ ✓ 1, 1-1/2, 2, 3 2 1/2 "142-148 NW 105 LW" 3 2 1/2 "145-151 NW 109-115 LW" 1, 1-1/2, 2 2 1/2 1, 1-1/2, 2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N N N N N D303 N N N N N N 3 D703 ✓ ✓ N 3 D708 ✓ ✓ ✓ ✓ N 3 D712 ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D722 ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D739 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ "147-153 NW 110 LW" ✓ ✓ ✓ 2 1/2 "142-148 NW 112 LW" 1, 1-1/2, 2, 3, 4 2 1/2 "142-148 NW 102-120 LW (110 LW with joists)" ✓ ✓ ✓ ✓ 2 2 1/2 147-153 NW ✓ ✓ ✓ ✓ 1, 1-1/2, 2, 3 2 "147-153 NW 107-113 LW" 2 2 1/2 "142-148 NW 105-111 LW" ✓ ✓ ✓ ✓ 3, 4 3 1/4 115-121 LW 2 1/2 "147-13 NW 109-115 LW" D740 N D743 ✓ ✓ ✓ ✓ N ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D750 ✓ ✓ ✓ ✓ ✓ ✓ ✓ N/A D754 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 3 D755 Composite and Non-Composite Deck Catalog • February 2016 11 ACUSTADEK® ✓ ✓ D PANEL N ✓ ✓ www.ascsd.com N D502 ✓ ✓ 2, 3 D216 3 ✓ ✓ ✓ ✓ ✓ ✓ 3 C PANELS 1 1 1/2 UL Design Number ✓ ✓ N PANELS ✓ ✓ ✓ B PANELS ✓ ✓ ✓ ✓ Note 3WxHF-36 3WxH-36 2WHF-36 2WH-36 NHF-32 NHN-32 NH-32 BHF-36 BHN-351⁄4 "147-153 NW 107-113 LW" BHN-36 1, 1-1/2, 2, 3 varies depending on accustic material, see UL listing BH-36 pcf CF 1-3/8 in 2W PANELS hr Deck3 3W PANELS Concrete Restrained Assembly Rating8 Thickness Type Smooth SeriesTM Option Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE GENERAL INFORMATION Fire Ratings 1.4 TABLE OF CONTENTS 1.4 Fire Ratings Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE Fire Proofing2 On UL Design Number Unrestrained Assembly Rating8 Minimum Beam or Joist D759 W8x28, 12K5, 12" deep OWSJ at 7.1plf 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 with beams, 6x6 W2.9xW2.9 with joists, Fiber reinforcement SFRM SFRM D760 W8x28, OWSJ 1, 1-1/2, 2, 3, 4 6x6 W1.4xW1.4 SFRM SFRM D764 W8x28, OWSJ 2 6x6, 6x6 SWG SFRM SFRM D767 W8x28, W6x12,OWSJ, Cast in place concrete beams 1, 1-1/2, 2, 3, 4 6x6 W1.4xW1.4 with beams, 6x6 W2.9xW2.9 with OWSJ SFRM SFRM D768 W10x17 1-1/2, 3 6x6 W2.9xW2.9 SFRM SFRM D775 W8x21 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM D779 W8x28, 8K1 1, 1-1/2, 2, 3, 4 6x6 W1.4xW1.4, Synthetic fibers SFRM SFRM D782 W8x28, 10" Deep OWSJ 1, 1-1/2, 2, 3, 4 6x6 W1.4xW1.4 SFRM SFRM D788 W8x28, 10K1 1, 1-1/2, 2, 3, 4 6x6 8x8 SWG SFRM SFRM D794 W8x28, OWSJ 2 6x6 6x6 SWG SFRM SFRM D795 W8x28, OWSJ 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 with beams, 6x6 W2.9xW2.9 with OWSJ SFRM SFRM D798 W8x28, OWSJ 1, 1-1/2, 2, 3, 4 6x6 10X10 with beams, 6x6 W1.4xW1.4 with OWSJ SFRM SFRM D799 W8x28, 10K1 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 with beams, 6x6 W2.9xW2.9 with OWSJ SFRM SFRM D825 W8x17 1, 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM D826 W8x20 0 6x6 W1.4xW1.4 SFRM SFRM D832 W8x24, W8x28 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM D833 W10x25 2, 3 WWF Optional SFRM SFRM D840 W8x28 0 6x6 10x10 SWG SFRM SFRM D858 W10x25, Concrete beam 1, 1-1/2, 2, 3, 4 6x6 W1.4xW1.4 SFRM SFRM D859 W8x20 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM 12 Minimum Concrete Reinforcing hr Composite and Non-Composite Deck Catalog • February 2016 Beam Deck www.ascsd.com TABLE OF CONTENTS "144-150 NW 107-113 LW" ✓ ✓ ✓ 2 2 1/2 117 LW ✓ ✓ ✓ ✓ 1, 1-1/2, 2, 3, 4 2 1/2 "142-148 NW 102-120 LW (110 LW with joists)" 3 2 1/2 2 Note UL Design Number 2 1/2 3WxHF-36 2, 3, 4 3WxH-36 ✓ ✓ ✓ ✓ 2WHF-36 "147-13 NW 109-115 LW" 2WH-36 2 1/2 NHF-32 1, 1-1/2, 2, 3 NHN-32 pcf ✓ ✓ N D759 ✓ ✓ N D760 ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D764 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D767 "145-151 NW 109-115 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D768 2 1/2 "142-148 NW 105-111 LW" ✓ ✓ ✓ ✓ ✓ 1, 1-1/2, 2, 3, 4 2 1/2 "142-148 NW 102-120 LW" ✓ ✓ ✓ ✓ ✓ 1, 1-1/2, 2, 3, 4 3 1/4 115-121 LW ✓ ✓ ✓ 1, 1-1/2, 2, 3, 4 2 1/2 "NW LW" ✓ ✓ ✓ ✓ ✓ 2 2 1/2 "147-153 NW 117 LW" 1, 1-1/2, 2, 3 2 1/2 1, 1-1/2, 2, 3, 4 D775 ✓ ✓ N/A D779 ✓ ✓ ✓ ✓ N/A D782 ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D788 ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D794 "147-153 NW 109-115 LW" ✓ ✓ ✓ ✓ ✓ N D795 2 1/2 "142-148 NW 107-113 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ N/A D798 1, 1-1/2, 2, 3 2 1/2 "147-153 NW 109-115 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D799 2 2 1/2 "147-153 NW 105-111 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D825 2 3 1/4 108-114 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D826 1, 1-1/2, 2, 3 2 1/2 "147-153 NW 109-115 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D832 2, 3 2 1/2 "147-153 NW 109-115 LW" ✓ ✓ ✓ ✓ N 3 D833 3 1/4 107-113 LW 107-116 LW 3 1/2 107-120 LW ✓ ✓ ✓ ✓ ✓ ✓ N 3 1/4 ✓ ✓ ✓ ✓ ✓ ✓ 1, 1-1/2, 2, 3, 4 2 1/2 "147-153 NW 108-115 LW" ✓ ✓ 1, 1-1/2, 2, 3 2 "142-148 NW 108-115 LW" ✓ ✓ ✓ ✓ 2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ D840 N N N/A 3 D858 N 3 D859 Composite and Non-Composite Deck Catalog • February 2016 13 ACUSTADEK® www.ascsd.com ✓ ✓ ✓ ✓ D PANEL N/A C PANELS ✓ N PANELS ✓ ✓ ✓ ✓ ✓ B PANELS in 2W PANELS hr NH-32 BHF-36 BHN-351⁄4 BHN-36 BH-36 CF 1-3/8 Deck3 3W PANELS Concrete Restrained Assembly Rating8 Thickness Type Smooth SeriesTM Option Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE GENERAL INFORMATION Fire Ratings 1.4 TABLE OF CONTENTS 1.4 Fire Ratings Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE Fire Proofing2 On UL Design Number Unrestrained Assembly Rating8 Minimum Beam or Joist D861 W8x15, W10x25 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM D862 W8x21 1 6x6 W1.4xW1.4 SFRM SFRM D867 W8x18 1-1/2, 2 6x6 6x6 SWG SFRM SFRM D871 W8x21, Concrete beam 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM D875 W8x20 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM D877 W8x17 1, 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM D878 W8x20 0 6x6 W1.4xW1.4 SFRM SFRM D883 W8x24, W8x28 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM D884 W10x25 2, 3 WWF Optional SFRM SFRM D888 W8x28 0 6x6 10x10 SWG SFRM None D891 W10x25, Concrete beam 1, 1-1/2, 2, 3, 4 6x6 W1.4xW1.4 SFRM SFRM D892 W8x15, W10x25 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM D893 W8x21 1 6x6 W1.4xW1.4 SFRM SFRM D898 W8x21, Concrete beam 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM D902 W12x14, W8x28, W8x24, W6x21, 8K1, 12K5, OWSJ 1, 1-1/2, 2, 3 6x6 10x10 SWG, Fiber reinforcement SFRM none 14 Minimum Concrete Reinforcing hr Composite and Non-Composite Deck Catalog • February 2016 Beam Deck www.ascsd.com TABLE OF CONTENTS 1, 1-1/2, 2, 3 Note UL Design Number 2 1/2 3WxHF-36 1, 1-1/2, 2, 3 3WxH-36 "144-150 NW 107-113 LW" 2WHF-36 - 2WH-36 3 NHF-32 99-105 LW NHN-32 2 1/2 NH-32 2 BHF-36 "137-150 NW 107-115 LW" BHN-351⁄4 2 1/2 BHN-36 2 BH-36 pcf CF 1-3/8 in N D861 ✓ ✓ ✓ ✓ N/A D862 ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D867 "147-153 NW 108-115 LW" ✓ ✓ ✓ N 3 D871 2 "142-148 NW 108-115 LW" ✓ ✓ N/A 3 D875 2 2 1/2 "147-153 NW 105-111 LW" ✓ ✓ N/A 3 D877 2 3 1/4 108-114 LW ✓ ✓ N/A 3 D878 1, 1-1/2, 2, 3 2 1/2 "147-153 NW 109-115 LW" ✓ ✓ N/A 3 D883 2, 3 2 1/2 "147-153 NW 107-115 LW" ✓ N/A 3 D884 3 1/4 107-113 LW 3 1/4 107-116 LW 3 1/2 107-120 LW 1, 1-1/2, 2, 3, 4 2 1/2 2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N/A "147-153 NW 108-115 LW" ✓ ✓ N/A 3 D891 2 1/2 "137-150 NW 107-115 LW" ✓ N/A 3 D892 2 2 1/2 109-115 LW ✓ ✓ N/A 1, 1-1/2, 2, 3 2 1/2 "147-153 NW 108-115 LW" ✓ ✓ N/A 1 3 1/2 147-153 NW 1-1/2 4 147-153 NW 2 4 1/2 147-153 NW 3 5 1/4 147-153 NW 1 2 1/2 107-113 LW 1-1/2 3 107-113 LW 2 3 1/4 107-113 LW 2 3 1/4 107-116 LW 3 4 3/16 107-113 LW 1 2 5/8 107-120 LW 2 3 1/2 114-120 LW 3 4 7/16 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ D893 3 D898 Y Y Y Y Y Y Y D902 Y Y Y ACUSTADEK® ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ D888 D PANEL www.ascsd.com ✓ ✓ ✓ ✓ ✓ ✓ C PANELS ✓ ✓ ✓ 2 ✓ ✓ ✓ N PANELS ✓ B PANELS ✓ 2W PANELS hr Deck3 3W PANELS Concrete Restrained Assembly Rating8 Thickness Type Smooth SeriesTM Option Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE GENERAL INFORMATION Fire Ratings 1.4 Y Y Composite and Non-Composite Deck Catalog • February 2016 15 TABLE OF CONTENTS 1.4 Fire Ratings UL Design Number Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE Minimum Beam or Joist Unrestrained Assembly Rating8 Minimum Concrete Reinforcing hr Fire Proofing2 On Beam Deck D907 D914 W8x17, W8x28 0 6x6 W1.4xW1.4 SFRM none W8x28 0 6x6 W1.4xW1.4 SFRM none D916 W8x28, OWSJ 0 6x6 10x10 SWG SFRM none D918 W8x20 0 6x6 W1.4xW1.4 SFRM none D919 W8x28 0 6x6 W1.4xW1.4 SFRM none D920 D922 W8x28 0 6x6 W1.4xW1.4 SFRM none W8x28, OWSJ 0 6x6 10x10 SWG SFRM none 16 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 5 1/4 147-153 NW 3/4 or 1 2 1/2 107-113 LW 1-1/2 3 107-113 LW 2 3 1/4 107-113 LW 2 3 1/4 107-116 LW 3 4 3/16 107-113 LW 1 2 5/8 107-120 LW 2 3 1/2 114-120 LW 3 4 7/16 114-120 LW 1 3 1/2 150-156 NW 1-1/2 4 150-156 NW 2 4 1/2 150-156 NW 3 5 1/4 150-156 NW 1 2 1/2 107-113 LW 2 3 1/4 107-113 LW 3 4 3/16 107-113 LW 2 3 1/2 107-120 LW 3 4 7/16 107-120 LW 1 3 1/2 147-153 NW 1-1/2 4 147-153 NW 2 4 1/2 147-153 NW 3 5 1/4 147-153 NW 1 2 1/2 107-113 LW 1-1/2 3 107-113 LW 2 3 1/4 107-116 LW 3 4 3/16 107-113 LW 2 3 1/2 114-120 LW 3 4 7/16 114-120 LW 2 3 1/4 110-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Refer to D916 for these values. www.ascsd.com Note ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ UL Design Number 3 3WxHF-36 147-153 NW 3WxH-36 4 1/2 2WHF-36 2 2WH-36 147-153 NW NHF-32 4 NHN-32 1-1/2 NH-32 147-153 NW BHF-36 3 1/2 BHN-351⁄4 1 BHN-36 110 LW BH-36 2 1/2 CF 1-3/8 3/4, 1 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ D907 D914 Y Y Y Y Y Y Y Y D916 Y Y Y Y Y Y Y Y Y Y Y D918 4, 5 Y Y Y Y Y Y Y Y Y Y D919 D920 D922 ACUSTADEK® 110 LW D PANEL 3 1/4 C PANELS 2 N PANELS pcf B PANELS in 2W PANELS hr Deck3 3W PANELS Concrete Restrained Assembly Rating8 Thickness Type Smooth SeriesTM Option Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE GENERAL INFORMATION Fire Ratings 1.4 Y Y Y Y Y Composite and Non-Composite Deck Catalog • February 2016 17 TABLE OF CONTENTS 1.4 Fire Ratings Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE UL Design Number Unrestrained Assembly Rating8 Fire Proofing2 On Minimum Beam or Joist D923 W8x28 0 6x6 10x10 SWG SFRM none D924 W8x28 0 Synthetic fibers, negative reinforcing steel SFRM none D925 W8x28, W8x16, 8K1 OWSJ 0 6x6 10x10 SWG or negative bending SFRM reinforcement with synthetic fibers none D927 D929 D931 D949 W8x28, OWSJ W8x28 W8x28 W8x28 0 0 0 or 1 0 6x6 10x10 SWG 6x6 10x10 SWG 6x6 10x10 SWG 6x6 10x10 SWG D957 W12x14, W8x28, W8x24, W6x12, OWSJ 1, 1-1/2, 2, 3 6x6 10x10 SWG 18 Minimum Concrete Reinforcing hr Composite and Non-Composite Deck Catalog • February 2016 Beam Deck SFRM SFRM SFRM SFRM none none none none none www.ascsd.com TABLE OF CONTENTS 147-153 NW 1 2 1/2 107-113 LW 107-113 LW 3 1/4 107-113 LW 2 3 1/4 107-116 LW 3 4 3/16 107-113 LW 1 2 5/8 107-120 LW 2 3 1/2 107-120 LW 3 4 7/16 107-120 LW 2 4 1/8 142-148 NW 2 4 3/8 142-148 NW 2 3 1/8 105-111 LW 3 5 142-148 NW 3 5 3/8 142-148 NW 3 4 105-111 LW 1-1/2 4 147-153 NW 2 4 1/2 147-153 NW 3 5 1/4 147-153 NW 1 2 1/2 107-113 LW 1-1/2 3 107-113 LW 2 3 1/4 107-113 LW 2 3 1/4 107-116 LW 3 4 3/16 107-113 LW 1 2 5/8 107-120 LW 2 3 1/2 114-120 LW 3 4 7/16 114-120 LW www.ascsd.com ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Note ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y Y Y Y Y Y D923 Y Y Y Y Y Y N/A 4 N/A 5 N/A N/A 4 N/A 5 D924 N/A Refer to D902 for these values. D925 Refer to D916 for these values. Refer to D916 for these values. Refer to D902 for these values. Refer to D916 for these values. D927 D929 D931 D949 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y Y Y Y Y Y Y D957 Y Y Y ACUSTADEK® 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ D PANEL 3 1/2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ C PANELS 1 ✓ ✓ ✓ ✓ ✓ ✓ ✓ N PANELS 3 2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ B PANELS 1-1/2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ UL Design Number 5 1/4 3WxHF-36 3 3WxH-36 147-153 NW 2WHF-36 4 1/2 2WH-36 2 NHF-32 147-153 NW NHN-32 4 NH-32 1-1/2 BHF-36 147-153 NW BHN-351⁄4 3 1/2 BHN-36 1 BH-36 pcf CF 1-3/8 in 2W PANELS hr Deck3 3W PANELS Concrete Restrained Assembly Rating8 Thickness Type Smooth SeriesTM Option Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE GENERAL INFORMATION Fire Ratings 1.4 Y Y Composite and Non-Composite Deck Catalog • February 2016 19 TABLE OF CONTENTS 1.4 Fire Ratings Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE UL Design Number Unrestrained Assembly Rating8 Fire Proofing2 On Minimum Beam or Joist D967 W8x28 0 6x6 W1.4xW1.4 D968 W8x28 0 6x6 W1.4xW1.4 none D973 D974 D975 D976 D977 W8x28 0 Fiber - Ultra Fiber 500 none W8x28 1-1/2 6x6 10x10 SWG none W8x28, W8x24, W6x12 1, 1-1/2, 2, 3 6x6 10x10 SWG none W8x28 OWSJ 1, 1-1/2, 2 6x6 8x8 SWG none W8x28, OWSJ 1, 1-1/2 6x6 8x8 SWG none D985 W8x28, 10K1 0 6x6 10x10 SWG none D988 W8x28, 10K1 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 none Minimum Concrete Reinforcing hr Beam Deck SFRM none Table Notes: 1. This table summarizes ASC Steel Deck's UL fire listings. Refer to the UL website for the most accurate and up-to-date listings. 2. SFRM = Spray-Applied Fire Resistive Material. 3. ASC Steel Deck may be used as blend deck with other manufacturers electrified cellular deck or trench. 4. Carbonate Aggregate. 5. Siliceous Aggregate. 6. BK Holding Corp. Ultra Fiber 500® 7. Syntheon Inc. Elemix® XE and Grey XE concrete additive. 8. For restrained fire ratings see UL listng for additional requirements. 20 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 147-153 NW 3 5 1/4 147-153 NW 2 1/2 107-113 LW 3 107-113 LW 2 3 1/4 107-116 LW 3 4 3/16 107-113 LW 2 3 1/2 114-120 LW 3 4 7/16 114-120 LW 2 3 3/4 142-148 NW 3 4 1/2 114-120 NW Note Y Y Y Y Y D968 Y Y Y B PANELS 1 1-1/2 D967 N/A ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y Y 6 ✓ N/A 7 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N/A 7 1, 1-1/2, 2 3 1/2 112.5-106.5 LW N/A 7 1 3 1/2 147-153 NW 1-1/2 4 147-153 NW 2 4 1/2 147-153 NW 3 5 1/4 147-153 NW 3/4 or 1 2 1/2 107-113 LW 1-1/2 3 107-113 LW 2 3 1/4 107-113 LW 2 3 1/4 107-116 LW 3 4 3/16 107-113 LW 1 2 5/8 107-120 LW 2 3 1/2 114-120 LW 3 4 7/16 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Refer to D902 for these values. ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N N N N N N N D985 N N N N N D988 D PANEL 111-117 NW C PANELS 3 1/2 D973 D974 D975 D976 D977 N PANELS N/A Refer to D957 for these values. 1, 1-1/2, 2 UL Design Number 4 1/2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 3WxHF-36 2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 3WxH-36 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2WHF-36 4 2WH-36 1-1/2 NHF-32 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ NHN-32 3 1/2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ NH-32 1 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ BHF-36 110 LW BHN-351⁄4 2 1/2 BHN-36 3/4, 1 BH-36 pcf CF 1-3/8 in 2W PANELS hr Deck3 3W PANELS Concrete Restrained Assembly Rating8 Thickness Type Smooth SeriesTM Option Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE GENERAL INFORMATION Fire Ratings 1.4 ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 21 TABLE OF CONTENTS 1.5 Steel Deck Section Properties Section Properties All of ASC Steel Deck's section properties are calculated in accordance with the American Iron and Steel Institute Specification for the Design of Cold-Formed Steel Structural Members, AISI S100-2012, Section B. Section properties can be used to develop the bending capacity of the steel deck for out-of-plane loads, which are typically defined by gravity for composite decks carrying construction and fluid concrete loads. The section properties for steel floor deck, like other coldformed steel members such as Cee, Zee, hat-shaped purlins, studs, and track are based on post-buckling strength. Post-buckling strength is based on the concept that compression flanges and portions of webs will exhibit some local buckling prior to the load capacity of the member being reached. To account for this, the widths of the flat compression elements of the steel deck are reduced for the purpose of determining the section properties, excluding the portion that can no longer effectively carry compression loads. This reduction of the gross section properties results in the effective section properties. Steel Thickness The thickness of steel floor deck is typically specified by a gage designation. The design of steel deck is dependent on the specified design base steel thickness in accordance with AISI S100-2012. The base steel thickness should not be confused with the total coated thickness, which is the combined thickness of the base steel, the optional galvanizing thickness, and any factoryapplied paint system thickness. The minimum acceptable base steel thickness to be supplied shall not be less than 95% of the design base steel thickness. This is specified in Section A2.4 Delivered Minimum Thickness of AISI S100-2012. Some standards reference non-mandatory tables that list the thickness of sheet steel by gage designation. These include the AISC Manual of Steel Construction in the Miscellaneous Information section of the appendix and AWS D1.3 in the Annex. Both references indicate that the values are nonmandatory and are for reference only. The nominal total coated thicknesses listed for each gage in these sources should not be used to determine if the cold-formed steel structural member, including steel deck, meets the minimum thickness requirement for the specified gage. Effective Section Properties Effective section properties for a steel deck panel are used to check for the maximum bending and axial load capacities. of the compression elements decreases as the localized plate-like buckling increases. The bending capacity of the deck increases with the increase in the grade of steel even though the effective section properties are decreasing. The increasing strength of the steel outpaces the decrease in effective section properties leading to higher bending capacities. Steel deck cannot be compared based strictly on effective section properties without considering the grade of the steel because of the effect on the effective section properties by the grade of steel. Figure 1.5.1 demonstrates this for BH-36 steel deck. 20 Gage BH-36 Steel Deck Panel Yield ksi Ie+ (in4/ft) Ie(in4/ft) Se+ (in3/ft) Se(in3/ft) Mn+ (Kip-in/ft) 33 37 40 50 55 80 0.193 0.187 0.187 0.177 0.177 0.173 0.237 0.233 0.233 0.227 0.227 0.223 0.235 0.233 0.232 0.228 0.227 0.218 0.251 0.247 0.244 0.236 0.233 0.230 4.65 5.17 5.56 6.83 7.34 7.84 Figure 1.5.1: EFFECTIVE SECTION PROPERTIES Many steel deck panels are not symmetric. In most cases, the top and bottom flange widths are not equivalent. The bending stress and location of the neutral axis is therefore different for positive and negative bending, resulting in different positive and negative section properties. Gross Section Properties The gross section properties of the steel deck are based on the entire cross section of the panel. Determination of gross section properties assumes that there is compression buckling of the compression flanges or web elements of the steel deck, therefore there are no ineffective elements. The gross section properties are used in combination with effective section properties to determine the deflection of the steel deck under uniform out-of-plane loads and for checking axial compression and bending. Service Load Section Properties The service load moment of inertia is used to determine the deflection of the steel deck for out-of-plane loads. The calculated moments of inertia are determined at a working stress level of 0.6Fy. Following accepted practice, the hybrid moment of inertia is based on the sum of two times the effective moment of inertia, and the gross moment of inertia divided by three, as follows: The effective properties are determined at the full yield stress of the steel. As the grade of steel increases, the effective section properties decrease. The effective width 22 Composite and Non-Composite Deck Catalog • February 2016 Id = 2Ie + I g 3 www.ascsd.com TABLE OF CONTENTS GENERAL INFORMATION Steel Deck Section Properties 1.5 How to Read Section Properties Table Gross Section Properties are Identified by the Subscript, g Base Metal Thickness (without Coating) Panel Gage 3W PANELS Weight of Panel Section Per SQFT Effective Section Properties are Identified by the Subscript, e 2W PANELS B PANELS N PANELS Effective Net Area of Section Hybrid Moment of Inertia for Uniform Load Condition Only C PANELS Effective Section Properties at Service Load Conditions Positive and Negative Effective Moment of Inertia for Non-Uniform Load Conditions Figure 1.5.2: SAMPLE OF PANEL PROPERTIES TABLE D PANEL www.ascsd.com with high bending stress that are at or above the onset of localized compression buckling exhibit progressively lower effective section properties as the bending stress goes up. Using the weighted average of the gross and effective section properties is an effective method to address deflections in which section properties change depending on the bending stress. Composite and Non-Composite Deck Catalog • February 2016 23 ACUSTADEK® This deflection equation for uniformly distributed loads takes into account that throughout the length of the span, portions of the steel deck will have low bending stress and others will have high bending stress. The areas with low bending stress exhibit behavior based on gross section properties because the stress is below the onset of localized compression buckling. The portions TABLE OF CONTENTS 1.6 Web Crippling Steel Deck Reactions at Supports Steel deck reactions at supports are governed by the web crippling capacity of the steel deck webs on the supporting member. This is calculated in accordance with Section C3.4 of AISI S100-2012 for multi-web steel decks. Reactions Due to Uniform Loads The end and interior reactions listed in the tables in this catalog are for a uniformly distributed out-of-plane load applied to the deck (See figure 1.6.1 and 1.6.2). UNIFORM DISTRIBUTION LOAD R, EN D RE ACT IO Point or Line Load Reactions For load conditions that exceed the uniform reaction capacity tables, including point loads and line loads on the steel deck panel, the maximum reaction capacity should be based on the web crippling capacity for the steel deck. For reactions exceeding the published values, or for conditions other than a uniformly distributed load, the maximum reaction capacity shall be determined by the designer in accordance with section C3.4 of the North American Specifications for the Design of Cold-Formed Steel Structural Members for multi-web steel panels and the geometric constants presented in the web crippling tables for the deck panel. N (p R REA, INTER CTIO IOR N (p lf ) lf ) Figure 1.6.1: UNIFORM DISTRIBUTED OUT-OF-PLANE LOAD The allowable Rn/Ω and factored ϕRn reactions presented in the tables are in pounds per linear foot running axially along the support for a given deck-bearing length on the support (the support member width that the deck bears on). This is based on the web crippling capacity multiplied by the number of webs per foot. Figure 1.6.3 shows how to read the reaction tables in this catalog. Panels must be attached to supports with fastener patterns not less than the minimum attachment patterns shown for the deck panel. UNIFORM LOAD (psf) UNIFORM LOAD (psf) R UNIFORM LOAD (psf) R INTERIOR BEARING LENGTH Figure 1.6.2: SUPPORT REACTIONS 24 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS GENERAL INFORMATION Web Crippling 1.6 How to Read Web Crippling Table 3W PANELS Support Condition: Deck Panel End on Supports or Deck Panel Continuous Over Supports ASD Design Basis Panel Gage Bearing Length of Deck Panel Web on Support 2W PANELS LRFD Design Basis Gage B PANELS N PANELS Deck Panel Geometry C PANELS Allowable Reaction of Deck Panel on Interior Support with 2″ of bearing Allowable Reaction of Deck Panel on End Support with 1.5 Bearing Figure 1.6.3: SAMPLE OF WEB CRIPPLING TABLE D PANEL ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 25 TABLE OF CONTENTS 1.7 Steel Deck as a Concrete Form Introduction The design of deck as a form for concrete is based on ANSI/ SDI C-2011 for composite deck and ANSI/SDI NC-2010 for non-composite deck. The deck acts as a permanent form for the concrete. In addition to providing formwork for the concrete, the deck provides the tension reinforcing for composite deck-slab systems. The deck also provides a safety floor for erection and a working platform for construction trades. It is critical that the deck be designed to carry these loads to meet the expected performance. Maximum Unshored Span Tables The maximum unshored spans for single and uniform double or triple deck span conditions are included in the load tables for the deck in this catalog. This provides an easy to use design aid to help select the appropriate deck type and gage for a particular span. The maximum unshored spans are determined in accordance with ANSI/SDI C-2011. This design standard provides the minimum recommended loads the deck is required to support including the weight of the deck, concrete, and 20 psf uniform construction live load or 150 plf concentrated construction live load. These maximum unshored spans may not be appropriate for heavy construction live loads from concrete buggies, drive on deck laser screeds, or ride on power trowels. Maximum unshored spans for loading conditions and span conditions that exceed the load table should be determined by the designer of record for the project or the engineer responsible for the erection of the structure. In addition to considering the loading used to develop the maximum unshored span in the tables, the definition of span and maximum reactions at supports need to be considered. It is appropriate to consider the span as clear span between supports when the supports have relatively ridged flanges as compared to the deflection of the deck. On supports without ridged flanges such as cold-formed Cees, Zees, open web steel joists, and thin ledger angles, center-to-center span is more appropriate. The maximum spans may be governed by the maximum reaction capacity of the composite deck at supports. ASC Steel Deck does not specify a minimum bearing length of deck on a support, however, allowable and factored reaction tables are presented for each deck type. This provides the maximum reaction for the deck based on the bearing length of the deck on a support. This is limited by the web crippling capacity of the deck. The deck span may be limited by the maximum reactions for heavily loaded or long spanning deck. (See figure 1.6.2) Design Loads for Steel Deck as a Form Steel deck as a form should be designed to resist the anticipated construction loads applied to the steel deck. The design should meet the minimum design loads specified in ANSI/SDI C-2011 Standard for Composite Steel Floor Deck-Slabs. This standard provides the 26 minimum recommended loads and load combinations for steel deck as a form. This includes the dead weight of concrete, and 20 psf uniform construction live load or 150 lbs concentrate load per foot width of deck. Heavy equipment loads from concrete buggies, drive on deck laser screeds, and ride-on power trowels exceed the minimum design loads. It is critical that the maximum unshored spans be checked by the designer of record or the engineer responsible for the erection for the structure for heavy equipment loads on deck used as a form. ANSI/SDI C-2011 basic ASD combinations include the following used to develop the tables in this report. Wdc+wdd+wlc ANSI/SDI C-2011 Eq 2.4.1 Wdc+wdd+Plc ANSI/SDI C-2011 Eq. 2.4.2 Wdd+wcdl ≥ 50psf ANSI/SDI C-2011 Eq. 2.4.2 Wdc= dead weight of concrete1 Wdd= dead weight of the steel deck Wlc = uniform construction live load (combined with fluid concrete) not less than 20psf Wcdl= uniform construction live load (combined with bare deck) not less than 50psf Plc = concentrated construction live load per unit width of deck section; 150lbs on a one foot width Loading Note: 1. For form decks (non-composite), additional concrete dead load is required for single spans in accordance with ANSI/ SDI NC-2010 Design of Steel Deck as a Form The design of deck as a form is a straight forward engineering exercise. The deck is no more than a cold–formed steel beam spanning between the support framing. The provision of AISI S100 should be used to determine the strength of the deck. The bending moment, web shear, and reactions are determined using engineering mechanics for slender beams. ANSI/SDI C-2011, Appendix 1, shows loading configurations that are typically used for steel deck as a form. These do not address unequal spans and unique loading conditions. The maximum moment, web shear, and reactions are then checked against the strength of the deck to determine the appropriate deck type and gage for a project. The bending strength of a cold-formed steel deck should be determined in accordance with AISI S100. Allowable stress design is commonly used for determining the bending capacity of the steel deck. Combined bending and web shear is often ignored because the web shear stress is relatively small compared to the bending stress. The section properties for steel deck are provided in this catalog to aid in the design of deck exceeding the scope of the maximum unshored span tables. Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 3W PANELS The reactions of the steel deck at supports should be checked to ensure that the webs of the steel deck do not buckle. The allowable web crippling of the deck may be taken directly from the web crippling tables in this catalog. For conditions exceeding the scope of the tables, the web crippling will need to be determined in accordance with AISI S100. To help the designer, the flat width of the web (h), bend radius (r), and angle relative to the support (ϴ) are included in the tables. 2W PANELS It is important that deck used as a form does not over deflect. ANSI/SDI C-2011 limits deflection to L/180, but not to exceed ¾ inch. The deflection check is based on the weight of the deck and concrete using equations of engineering mechanics. Skip loading and constitution live loads are not considered because these loads are not present after the concrete is finished and during the curing time. For the maximum unshored span tables presented in this catalog, ASC Steel Deck allows for an additional 3 psf for normal weight concrete and 2 psf for lightweight concrete to account for added concrete due to deflection. ANSI/SDI C-2011, Appendix 1, has equations for deflection for common conditions. The actual deck deflection may vary from the predicted deflection, however, the predicted limits have proven to be reliable for the design of deck as a form. B PANELS N PANELS Cantilevers Cantilevering deck is an acceptable common solution to extending the composite deck-slab past a support and generally involves the use of a two piece pour stop as shown in figure 1.7.1. Cantilevers need to be designed by the engineer of record or the engineer responsible for the erection of the structure. The section properties included in this catalog provide the basic properties for this calculation. The cantilever should be designed in accordance with ANSI/SDI C-2011 section 2.4. C PANELS D PANEL Backspan(s) GENERAL INFORMATION Steel Deck as a Concrete Form 1.7 Cantilever Figure 1.7.1: Cantilevers ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 27 TABLE OF CONTENTS 1.8 Composite Deck-Slab Design General Design Principles The design of composite steel deck-slab systems reflect the basic engineering concepts used to design reinforced concrete beams. The concrete acts as the compression material, and the steel deck bonded to the bottom of the concrete acts as the tension steel. In this manner, the composite deck-slab behaves like a simple reinforced concrete beam in which the deck is the rebar. A composite deck-slab is most commonly designed as a simple span beam. The deck only provides positive bending reinforcement. The minimum temperature and shrinkage reinforcing is not adequate to develop negative bending over supports. With out any significant negative bending reinforcement over supports, the concrete is assumed to crack and the deck yield in negative bending, creating a condition in which the composite deck-slab is treated as a simple beam. (See figure 1.8.1) Tension Crack Uniform Load Tension Crack Figure 1.8.1: Single Span The maximum load carrying capacity of a composite deckslab system should be limited to the bending capacity, vertical shear, and maximum acceptable deflection. ANSI/ SDI C-2011 provides the design methods for composite steel deck-slab systems. The tables in this catalog provide an easy to use design aid following these methods. Superimposed Load Capacity The superimposed load that the composite deck-slab system carries are those loads that are in addition to the concrete and deck self-weight. These loads consist of outof-plane dead and live loads. Most composite deck-slab systems are designed using Allowable Stress Design (ASD). This is a convenient method because either calculations or load tables can be developed based on service loads. ASD design does not take into account the different load factors for dead and live loads of 1.2 and 1.6 respectively. Most ASD superimposed load calculations and load tables assume that the entire superimposed load is a live load using a load factor of approximately 1.6, which heavily favors live loads and is therefore conservative for dead loads. ASD is best suited for applications for which the majority of the load is live load, which is typical for most commercial building floor applications. Load and Resistance Factor Design (LRFD) is a more efficient method of design for superimposed loads that are primarily dead load. This method is more involved and is 28 only warranted in conditions in which ASD is unfavorable. An example would be a case in which a large portion of the superimposed load is dead load. In these situations, a great portion of the load would use a 1.2 load factor for dead load, and a smaller portion of the load would use a 1.6 load factor for live load. In these cases, an LRFD approach will prove to be more efficient if the maximum superimposed load carrying capacity is governing the design. LRFD is a good choice for composite deck-slab systems supporting heavy loads such as equipment pads and heavy planting beds for green roof systems or patio decks. Loading Composite deck-slab systems are a very efficient way to support many design loads. The loads should be static or semi-static in nature. These are typical of dead loads and typical commercial building live loads. Live loads that are cyclic or vibratory in nature, however, may break down the bond between the deck and slab over time. These loads should not be applied to composite deck-slab systems without supplemental reinforcing. Loads to watch out for: Vibratory or Cyclic Loads: Machinery that vibrates or applies a repetitive cyclic load should be avoided. This type of equipment may break down the bond between the concrete and deck due to vibration or high and localized bending and shear. Forklift Loads: Forklifts tend to create very high localized wheel loads that apply significant localized bending and shear to the composite deck-slab system and should be avoided. Hard Wheeled Loads: Heavily loaded hard wheeled carts may apply high localized bending and shear below the wheels that may approach the design capacity of the composite deck-slab system and should be avoided. These types of cyclic or vibratory loads may be applied to composite deck-slab systems if supplemental reinforcing designed to carry the load is added to the concrete section. In this case, the deck is considered a stay in place form, similar to a form deck. Parking Structures: Composite deck-slab systems have been used successfully for parking structures for many years. The combination of the relative light weight of automobiles with pneumatic tires that distribute the load and suspension, greatly reduce the effects of dynamic cyclic loading on the composite deck-slab system. For open parking structures, it is recommended that the slab be sealed to reduce possible corrosion of the steel deck from water penetrating cracks in the slab. Supplemental reinforcing in the slab is recommended in exposed conditions in which the deck could corrode over time. Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Fct Figure 1.8.2: Uncracked Section Cracked Section The cracked section for composite deck-slab systems is determined using methods similar to reinforced concrete design. For composite deck-slab systems, this is determined at a compressive yield stress in the concrete in which the flexural stress is still assumed to be linear elastic and the concrete in tension is cracked and is no longer contributing to the section properties. (See figure 1.8.3) The cracked moment of inertia is presented in the composite deck tables in this catalog for common slab conditions. For conditions exceeding the scope of the tables, the cracked moment of inertia should be calculated in accordance with ANSI/SDI C-2011 Appendix 4. Neutral Axis of Deck-Slab at Yield Fc Fs C PANELS Neutral Axis of Steel Deck Figure 1.8.3: Cracked Section Composite and Non-Composite Deck Catalog • February 2016 29 ACUSTADEK® Bending Capacity The flexural capacity for composite steel deck-slab systems is determined using methods similar to reinforced concrete design. In this catalog, the nominal bending capacity for deck-slab systems that are not anchored to the structure with headed shear stud anchors are developed using the ANSI/SDI C-2011 prequalified method. This is referred to as the yield method in which the nominal bending moment is limited to the point at which the steel deck begins to yield. This is determined using the cracked moment of inertia and the yield strength of the steel deck. The factored and allowable bending moments for common composite steel deck-slab systems are listed in the tables in this catalog. For conditions exceeding the scope of the tables, the bending capacity should be calculated in accordance with ANSI/SDI C-2011 pre-qualified sections D PANEL www.ascsd.com Neutral Axis of Steel Deck N PANELS UnCracked Section The uncracked section for composite steel deck-slab systems is analogues to reinforced concrete design. The uncracked section properties are determined at low bending stress, in which the concrete is still effective in tension. This is the condition in which the concrete in tension, has not cracked, and still contributes to the section properties. (See figure 1.8.2) The uncracked moment of inertia is presented in the composite deck tables in this report for common slab conditions. For conditions exceeding the scope of the table, the uncracked moment of inertia should be calculated in accordance with ANSD/SDI C-2011 Appendix 4. Fs B PANELS Composite Deck-Slab Section Properties The development of section properties for composite deck-slab assemblies follows the engineering mechanics used to develop section properties for reinforced concrete design. The convention in design of composite deck-slab systems is to use the transformed section to convert the area of steel into an equivalent area of concrete. The transformed section properties are then used to determine the nominal bending moment and predicted deflections for the composite deck-slab section. Fc 2W PANELS Temperature and Shrinkage Reinforcing Reinforcing should be provided in the concrete to prevent temperature and shrinkage cracking. This can be accomplished with welded wire fabric, reinforcing steel, or fibers. The minimum steel reinforcing should not be less than 0.00075 times the area of the concrete, but not less than 6x6 Wl.4xWl.4 welded wire fabric. Steel fibers may be used when the concrete is designed in accordance with ASTM C1116 type I with steel fibers per ASTM A820 type I, II or V, provided at the manufactures recommended dosage, but not less than 25lbs/cy. Macro synthetic fibers may be used when the concrete is designed in accordance with ASTM C 1116 type III, with fibers in accordance with ASTM D7508 provided at the manufacturers recommended dosage, but not less than 4lbs/cy. Other types of fibers that effectively resist temperature and shrinkage cracking may be used at the fiber manufactures recommended dosage. This is appropriate because any increase in concrete strength that may result from temperature and shrinkage control using fibers is not considered when developing the load carrying capacity of the composite deck-slab. Neutral Axis of Deck-Slab at ≤ Fct 3W PANELS Concrete Composite steel deck utilizes structural concrete fill poured over the top of the steel deck. The design of the concrete should be in accordance with ACI 318 with a minimum compressive strength of 3000psi. ASC Steel Deck's load tables are based on either 145 pcf normal weight concrete or 110 pcf lightweight concrete. Composite deck systems can be designed with lower or higher density light weight concrete, but it is important that the effect on fire rating be considered if applicable to the project. GENERAL INFORMATION Composite Deck-Slab Design 1.8 TABLE OF CONTENTS 1.8 Composite Deck-Slab Design method. The embossment factor (K) for this method is presented in General Note 7 of section 1.18, Composite Deck-Slab Table General Requirements along with the embossment geometry. Vertical Shear The vertical shear capacity for a composite deck-slab system is the combination of the shear contribution of the concrete and the steel deck. The factored and allowable vertical shears are presented in the tables in this catalog. For conditions that exceed the tables, the shear should be determined in accordance with ANSI/SDI C-2011. Deflection The deflection of a composite deck-slab system should be checked to ensure serviceability of the system for its intended use. The superimposed load tables in this catalog have been limited to strength or L/360 deflection limit. L/360 was chosen because it is the typical live load deflection limit for floor systems. Deflection was checked using the average of the cracked and uncracked section properties. Id = Iu + Ic 2 The average moment of inertia for deflection (Id) is presented in the tables in this catalog for common conditions. This can be used to check the deflection for both lower and higher deflection limits. Concentrated Load Concentrated point loads and line loads should be checked using the composite deck properties including the maximum bending moment, vertical shear, and moment of inertia for the deflection check. ANSI/ SDI C-2011 section 9 provides a general solution for concentrated loads on steel deck, including the design of load distribution reinforcing in the slab. n 30 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Temperature and Shrinkage Reinforcement The minimum reinforcing for temperature and shrinkage control should be in accordance with ACI 318. Non-Composite Deck Load Tables Non-composite deck uniform load tables are provided in this catalog. The tables include the maximum unshored span and the maximum uniform load capacity of the noncomposite deck. 2W PANELS Deck as a Form The design of deck as a form shall be in accordance with ANSI/SDI NC-2010. Section 1.7 of this catalog discusses the design of deck as a form. Concrete Slab Design The design of a concrete slab above a non-composite deck should be in accordance with ACI 318. This includes bending capacity, vertical shear, and diaphragm shear. It is acceptable to ignore the contribution of the concrete in the flutes of the deck when designing the concrete section. For this method of design, the minimum thickness of concrete above the steel deck is 11⁄2 inches. 3W PANELS General Non-composite steel deck design assumes that the steel deck and concrete do not interact to develop composite sections for bending. The design of non-composite deck should be done in accordance with ANSI/SDI NC-2010 Standard for Non-Composite Steel Floor Deck. The most common noncomposite deck design is to use the deck as a permanent form and to design the reinforced concrete in accordance with ACI 318. Another less common option is to design the deck to carry all the design loads, including the weight of the unreinforced concrete. For this option, the design of the deck should follow the provisions of AISI S100 Specification for the Design of Cold-Formed Steel Structural Members. GENERAL INFORMATION Non-Composite Deck-Slab Design 1.9 B PANELS N PANELS C PANELS D PANEL ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 31 TABLE OF CONTENTS 1.10 Penetrations and Openings General Openings and penetrations in composite deck-slab floor and roof structures are a normal part of every building. These can range from small pipe and conduit penetrations, to midsized openings for mechanical ductwork, to large openings for stair wells or elevator shafts. Small penetrations less than 12 inches across may not require much, if any, structural design consideration unless several are grouped closely together. Mid-sized openings up to 2 to 3 feet across most likely require design consideration to address the appropriate distribution of load around the opening for both deck as a form and the composite deck-slab system. Large openings are generally designed with support framing around the openings which is part of the overall framing for the composite deck-slab floor or roof system. It is difficult to have a “rule-of-thumb” for unscheduled openings because of the wide variety of building conditions. The information in this section should provide guidance toward addressing a wide range of penetrations and openings in the composite steel deck-slab system. Deck-Over or Cut-Out? The one major consideration which determines the complexity of designing penetrations or openings in the steel deck is whether to Deck-Over or Cut-Out the deck. This impacts how the penetration affects the deck as a form and what type of deck stiffeners or opening frames should be considered. For purposes of this catalog, when Decked-Over or Cut-Out are italicized they shall have the following definitions. Decked-Over: an opening or penetration through the deck-slab system in which the deck is placed, the penetration or opening is blocked out with formwork, Styrofoam, or edge form flashings without cutting the deck, the concrete is poured and allowed to adequately cure, then the deck is cut out when the opening is needed. (See figure 1.10.1) Steel Parallel Edge Form Steel Perpendicular Edge Form Styrofoam Blockout Figure 1.10.1: DECKED-OVER OPENINGS 32 Cut-Out: an opening or penetration through the deckslab system in which the deck is placed, the penetration or opening cut out, deck stiffeners or support frames are installed (if required), the opening is flashed with edge form or sleeving cans, then concrete is poured and allowed to cure. Penetrations or openings that are Decked-Over have several key advantages, including simplifying the design of the deck as a form and providing fall-protection safety for mid-size and large openings. When the Decked-Over approach is used, the steel deck bending capacity and vertical shear capacity is not reduced from an opening being cut in the deck. In the Decked-Over case, no additional design effort needs to be considered because unshored spans do not change as the bending capacity and vertical shear capacity have not been reduced. Another advantage for mid-sized and larger openings is that the deck provides the fall protection, eliminating the need to plank over or put up handrails around the openings in accordance with OSHA regulations. The primary disadvantage of Decked-Over openings is that they cannot be cut out and utilized until after the concrete slab has been poured and had adequate time to cure. Penetrations or openings that are Cut-Out have the advantage of being immediately available for use. The disadvantage of Cut-Out openings is that the opening in the deck is cut out, therefore compromising the bending capacity and the vertical shear of the deck in the area of the opening. For small openings in most common conditions, the amount the deck is compromised is insignificant and can typically be ignored. For mid-size openings, the amount the deck is compromised is significant and will most likely require stiffening or a structural support frame. Another disadvantage is that CutOut openings also require fall protection planking or hand rails to prevent injuries in accordance with OSHA regulations. Small Size Penetrations Small size penetrations of 12 inches or less often do not require any structural design or detailing. These penetrations are typically for pipes, conduits, or small ductwork. It is up to the designer of record to determine whether specific design and detailing is required for small size penetrations. The following are common examples of methods to stiffen the deck around small openings and penetrations which may be considered by the designer. Decked-Over small penetrations is the recommended method because the designer does not need to consider whether the penetration will affect the capacity of the deck as a form, because the deck is not cut out. The only issue which may need to be considered is load distribution around the opening. If required, this can be accomplished by placing rebar to distribute the loads around the opening. For most common floor applications, this is not necessary for openings less than 12 inches unless several are grouped together. Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS rebar to distribute to the deck-slab adjacent to the openings. (See figure 1.10.3) Reinforced concrete design to distribute these loads perpendicular to the deck span should be done in accordance with ACI 318. Distribute 1 ⁄2 Tributary Load 2W PANELS Collect Tributary Load Figure 1.10.2: DECK SUPPORT ANGLES Cut-Out mid-sized openings require structural design and detailing of the deck as a form and the composite deck steel deck-slab. Cut-Out openings compromise the deck bending and shear capacity. For openings less than 2 feet, stiffener angles may be an acceptable solution similar to those used for small penetrations. The designer of record should verify the size of the stiffener and that the adjacent deck can support the concrete and construction loads. For all mid-sized openings, deck support frames may be a good option to support the deck for the concrete and construction loads. The designer of record should design and detail these frames around the mid-sized openings to transfer the loads back to the primary framing members supporting the composite steel deck. (See figure 1.10.4) Steel angles or channels are common framing materials for mid-sized openings. www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® Decked-Over mid-sized openings require less structural design and detailing than Cut-Out. If the opening is Decked-Over, the deck as a form is not compromised therefore no stiffening angles or support frames are required. The design should consider the effect of load transfer around mid-size openings for the composite steel deck-slab design. The superimposed load and dead load of the deck-slab needs to be distributed around the opening. This can be accomplished by using D PANEL Mid-Size Openings Mid-sized openings typically require some structural design and detailing consideration. These openings are typically for ductwork or other mechanical shafts. Mid-sized openings range from 1 foot to approximately 4 feet and cut through multiple webs of the composite steel deck. The following are common examples of how the design professional may address mid-size penetrations in their designs. Figure 1.10.3: REBAR DISTRIBUTION C PANELS Load Distribution Angle, Channel or tube Steel (Above or below the deck) Distribution Rebar Design in Accordance with ACI 318 N PANELS Distribute 1 ⁄2 Tributary Load Distribute 1 ⁄2 Tributary Load B PANELS Distribute 1 ⁄2 Tributary Load Collect Tributary Load 3W PANELS Cut-Out small penetrations may require the stiffening of the deck. Most small openings less than 6 inches which do not cut through more than 1 web of the deck does not require any reinforcing. Small Cut-Out penetrations less than 24 inches can be reinforced with stiffening angles, tube steel, or channels attached to the deck. (See figure 1.10.2) These details rely on the adjacent deck's reserve capacity to support the load distributed to those flutes due to the penetration CutOut. These distribution angles are an effective way to control localized deck deflection around the penetration Cut-Out. They do not, however, address possible overstress or over deflection of the adjacent flutes of the deck now carrying the load. Historically this type of detail has been demonstrated to be an effective solution for small penetrations. GENERAL INFORMATION Penetrations and Openings 1.10 33 TABLE OF CONTENTS 1.10 Penetrations and Openings Consideration for Groups of Openings When small sized Cut-Out penetrations are grouped together, the effect of the grouping may need to be treated as a mid-sized or large sized opening. Groups of small penetrations running along the edge of a support beam can compromise a large portion of the vertical shear capacity of both the deck as a form and the composite steel deck-slab system. (See figure 1.10.5) Opening Frame Channels, Angles or Small Wide Flanges Figure 1.10.4: DBL H OPENING FRAME Large Openings Large openings for stair wells, elevator shafts, or large mechanical shafts are typically supported by framing which is part of the primary building framing system supporting the composite steel deck-slab system. Decked-Over large openings are often not practical due to the large size of the opening. Most large openings do not fall into the Cut-Out category because the deck will be detailed around the opening with pour stops similar to edge of slab conditions. 34 Figure 1.10.5: ROW OF SMALL HOLES Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Collect Tributary Load Figure 1.10.7: SINGLE VS 2 PENETRATIONS N PANELS Distribution 1 ⁄2 Tributary Load When Perpendicular to Flute Treat as Single Net Opening Distribute 1 ⁄2 Tributary Load B PANELS Collect Tributary Load 2W PANELS Distribute 1 ⁄2 Tributary Load When Parallel to Flute Treat as one Small Opening The effect of two small holes in the same flute(s) of the deck panel may need no more consideration than a single penetration. The load from the flutes with the penetrations is distributed to the adjacent webs and is similar in magnitude to a single penetration. (See figure 1.10.7) 3W PANELS The effect of several small openings with stiffeners in proximity to each other may affect the overall capacity of the deck as a form or capacity of the composite deck-slab system. This may be an issue when the stiffening angles or penetrations overlap in a given span. The designer should consider the overlapping distribution of the load on the deck between openings to ensure the bending capacity of the deck is not exceeded (See figure 1.10.6) GENERAL INFORMATION Penetrations and Openings 1.10 Figure 1.10.6: OVERLAPPING HOLES C PANELS D PANEL ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 35 TABLE OF CONTENTS 1.11Composite and Non-Composite Diaphragm Shear General A composite steel deck-slab is an integral part of a building's horizontal diaphragm system. The composite deckslab acts as a shear resistant membrane supported by the steel framing supporting the diaphragm and providing the perimeter cords and collectors. The composite deck-slab tables in this catalog provide an easy to use design aid with factored diaphragm shears for common attachment types. spacing of the fasteners per sheet shall not be greater than the spacing of the parallel boundary fasteners. Fasteners may need to be doubled up in some flutes to achieve this. Shear Design of Diaphragms without Welded Shear Studs The diaphragm shear design of composite deck-slab systems may be performed in accordance with the SDI Diaphragm Design Manual. This method is used for deck which is not attached with headed shear stud anchors. Common attachment methods include arc spot welds, power actuated fasteners, and self-drilling screws. The side laps of the steel deck should be connected together to prevent concrete leakage and provide some shear contribution. The minimum side lap connection should be button punches at 36 inches on center. Diaphragm Boundary Fasteners to Supports The diaphragm boundary connections to supports, perpendicular to the deck, should be the specified attachment pattern in the composite tables for the given deck gage, concrete type, and slab thickness. Diaphragm boundary fastener spacing, parallel with the ribs of the deck, shall not exceed the spacing determined by: dividing the fastener shear strength by the required shear demand. Connector shear strengths are presented in figures 1.13.11 and 1.13.12 Spacing (in) = Q fa 12in sa ft Q ff 12in Spacing (in) = s f ft Qfa= Allowable fastener strength using the safety factor, Ω = 3.25, for composite deck-slab diaphragm shear in accordance with ANSI/SDI C-2011, lbs Qff = Factored fastener strength using the safety factor, Φ = 0.5, for composite deck-slab diaphragm shear in accordance with ANSI/SDI C-2011, lbs Sa = Allowable shear demand, lbs/ft Sf = Factored shear demand, lbs/ft Skew Cut Diaphragm At skew cut conditions, the minimum number of fasteners is determined based on the location of the fasteners in the ribs per the perpendicular attachment schedule. The average 36 S ≤S idth Panel Wasteners of F r e b m u N Figure 1.11.1: SKEW DIAPHRAGM Diaphragm Deflection Composite deck-slab diaphragms are very stiff with a flexibility factor, f<0.5micro inches/lbs (Shear stiffness, G’ > 2000 kip/inch). The specific predicted shear stiffness (G’) for a given composite deck-slab condition can be determined in accordance with the methods in ANSI/ SDI C-2011. Due to the very stiff nature of these systems, checking the shear deflection of the diaphragm is often not necessary. There may be occasions, however, to check diaphragm shear deflections for diaphragms with large length to depth ratios. For these conditions, the methods and equations of engineering mechanics presented for diaphragm deflections in the ASC Steel Deck Roof Deck Catalog may be used. Diaphragm Shear With Headed Shear Stud Anchors Diaphragms requiring diaphragm shears that exceed the limits of the arc spot welds, power actuated fasteners, or self-drilling screws may be developed using headed shear stud anchors and supplemental shear reinforcing in the concrete slab above the deck. This design is based on the transfer of shear from the collector into the reinforced concrete slab above the deck using headed shear stud anchors. The capacity of the diaphragm is limited by this shear transfer, or the capacity of the reinforced concrete diaphragm above the deck. The capacity of the headed shear stud anchors should be determined in accordance with AISC 360 requirements for composite beam design. The in-plane shear capacity for the reinforced concrete diaphragm above the deck should be determined in accordance with ACI 318 requirements for reinforced concrete design. The composite deck-slab tables in this catalog provide factored diaphragm shear capacities for common reinforcing schedules with ¾ inch diameter headed stud anchors. Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS GENERAL INFORMATION 3W PANELS 2W PANELS B PANELS N PANELS C PANELS D PANEL ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 37 TABLE OF CONTENTS 1.12Composite Deck-Slab Tables General The composite deck-slab load tables are intended to provide a designer with easy to use design aids for common composite deck-slab conditions. The tables provide uniform load in both allowable and factored superimposed loads. Factored diaphragm shears are provided for composite deck-slab systems for lateral design. Diaphragms may be attached with a variety of attachments to supports including traditional arc spot welds, power actuated fasteners (PAF), and self-drilling screws. Factored shear tables for diaphragms with steel reinforcing and headed shear stud anchors are provided for high shear diaphragms. All of these tables are supported with complete composite deck-slab properties including bending moment, vertical shear, and section properties to aid in the design of conditions exceeding the scope of the tables. Superimposed Uniform Load Tables Uniform superimposed load is the load which the composite deck-slab can carry in addition to its self-weight. Both allowable and factored superimposed loads are provided. The superimposed load tables assume that the minimum temperature and shrinkage reinforcement is not adequate to develop negative bending resistance at supports, therefore all spans are treated as simple spans. Most floor systems are designed using allowable stress design (ASD). The allowable superimposed load tables present the maximum uniform load based on the allowable bending strength, allowable vertical shear, and a deflection limit of L/360. ASD assumes that the superimposed load is primarily live load and is conservative for dead loads. Load and Resistance Factor Design (LRFD) is recommended for conditions in which the majority of the superimposed load is dead load, and the maximum superimposed load is the limiting design criteria. The factored superimposed loads in the tables do not include a deflection check. The designer will have to check the service load deflection to ensure that the deflection meets the projects deflection serviceability requirements when using an LRFD approach. Composite Deck-Slab Properties For conditions exceeding the scope of the uniform load tables, composite deck-slab properties are provided in the tables. The properties can be utilized as part of the solution for concentrated loads, deflection limits, or spans not included in the superimposed load tables. The properties include both allowable and factored moments, and vertical shear for determining the capacity of the composite deck-slab system. Cracked, uncracked, and the average of cracked and uncracked moment of inertia are provided to assist in determining the deflection of the deck-slab system. Factored Diaphragm Shear This catalog presents composite steel deck-slab diaphragm shears using a load and resistance factor basis. The diaphragm shears presented are factored shears. Composite steel deck-slab systems have traditionally been designed using allowable stress design (ASD), in part because manu- 38 factures have presented allowable shears. These shears were based on research and engineering studies dating back to before LRFD was commonly used for steel design. The factored shears presented in this catalog work seamlessly with the design of the lateral force resting system for steel and concrete buildings designed using the LRFD approach. The designer does not have to convert the lateral forces to ASD when selecting a factored diaphragm from the shear tables. Factored shears are provided for a variety of fastener types to supports. This range of fasteners reflects a full range of building types that composite deck-slab systems are used in. Wide Flange Multi-Story Steel Construction: Arc spot welds are the traditional method for attaching composite deck to structural steel support members. This method provides good shear performance and is applicable to a wide variety of support steel, from heavy wide flange beams to light weight open web steel joists. Welded steel headed stud anchors are commonly used for composite beam design. They are also a good choice to transfer large diaphragm forces into the composite deck-slab system. This system is ideal for high shear diaphragms on wide flange beams and requires the use of welded wire fabric or reinforcing bars in the slab. Open Web Steel Joist Mezzanine and Floor Systems: Composite steel deck-slab systems can be attached with arc spot welds, however, power actuated fasteners (PAF) are an ideal cost effective method of attachment to light structural angles used for open web steel joist framing. PAF selection is dependent on the support steel thickness. (See figure 1.13.12) Cold-Formed Steel Mezzanine and Floor Systems: Selfdrilling screws are the best choice for attaching composite steel deck to cold-formed steel framing. Common examples of this application include: cold-formed steel framed multistory mini-storage buildings, mezzanines, and conventional cold-formed steel stud, and joist framed buildings. Composite Deck-Slab with Cellular Deck Cellular composite deck panels can be conservatively designed using the non-cellular deck-slab tables. The superimposed loads, vertical shear, and moment of inertia can be conservatively used for the design, based on the gage of the beam section of the cellular profile. This ignores the contribution of the steel used for the bottom pan of the cellular deck. Maximum unshored spans for cellular deck-slab system are listed with the cellular deck section properties. Allowable Stress Design Historically, most composite steel deck-slab systems diaphragm shear tables have been presented using an allowable stress design basis. To compare composite steel deck-slabs designed using ASD basis, it is recommended that the ASD shear demand be converted back to an LRFD basis. This can be accomplished by dividing the required allowable shear by 0.7 ASD seismic factor, for seismic controlled designs, or 0.6 ASD wind factor for wind controlled designs. Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS How to Read Tables 3W PANELS 3WxH-36 Composite Deck 5" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.080yd3/100ft2 Theoretical concrete volume does not account for deflection Gage 22 21 20 Single 10' - 1" 11' - 0" 11' - 9" Vertical Load Span (in) GA cr u ASD & LRFD - Superimposed Load, W (psf) 8'-0" 443 8'-6" 389 9'-0" 343 9'-6" 304 10'-0" 271 10'-6" 243 11'-0" 218 11'-6" 197 12'-0" 178 12'-6" 162 13'-0" 147 Load, 315 W (psf)285 258 235 709 622 ASD 549 & LRFD 487 - Superimposed 434 389 349 282 246 216 190 169 150 134 119 107 96 86 451 394 345 304 270 240 214 191 171 154 138 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern 2679 2634 2594 2587 2554 2523 2496 2470 2447 2448 2427 / ft) 2258 36/4 Attachment LRFD - Diaphragm Shear,2292 ϕSn (plf 2352 2326 2303 2312 2274 2243 2229Pattern 2238 2226 2367 2304 2342 2282 2319 2292 2309 2273 2291 2256 2274 2240 2258 2226 2244 2213 2231 2223 2227 2211 2216 2328 2178 2163 2151 2150 2139 2129 2120 2112 2105 2106 2099 2311 2288 2267 2278 2259 2243 2228 2215 2202 2212 2201 2163 2150 2138 2137 2110 2102 2095 2096 2090 4 55.4 in2118 /ft 45.0 psf Icr = 2127 Mno/Ω= 47.9 kip-in/ft 2149 2137 2125 2126 2116 2107 2100 2092 2086 2088 2082 4 4 85.4 in /ft I = 115.4 in /ft ϕM = 73.2 kip-in/ft u 546 874 - 16 LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 2898 2840 2788 2786 2742 2702 PAF Base Steel ≥ .25" 2477 2443 2413 2431 2405 2381 PAF Base Steel ≥ 0.125" 2431 2400 2372 2393 2368 2346 #12 Screw Base Steel ≥ .0385" 2431 2400 2373 2393 2369 2346 All Gages Spacing of shear studs when used n 14'-6" 111 15'-0" 102 178 163 63 57 101 90 2374 2359 2194 2184 2187 2172 2178 2181 2082 2077 2171 2163 2074 2069 3.82 kip/ft 2066 2062 5.73 kip/ft Attachment Pattern 2633 2602 2609 2339 2321 2339 2308 2291 2310 2308 2291 2310 2581 2322 2294 2294 2556 2307 2279 2280 Mno/Ω= 58.3 kip-in/ft ϕMno= 89.2 kip-in/ft 2533 2292 2266 2266 2511 2279 2253 2254 12 in o.c. 24 in o.c. 36 in o.c. 6x6 W1.4xW1.4 As = 0.028 in2/ft 3200 3200 3200 6x6 W2.9xW2.9 As = 0.058 in2/ft 5540 5540 5170 4x4 W4xW4 As = 0.120 in2/ft 7340 7340 5170 Cracked & uncracked moment of inertia of deck-slab 2491 2266 2242 2242 Factored superimposed load Superimposed load that produces L/360 deflection Factored diaphragm shear corresponding to type of fastener Allowable factored vertical shear of deck slab Allowable factored momentum of deck slab 4x4 W6xW6 As = 0.180 in2/ft 10040 7750 5170 Factored diaphragm shear when studs are used on collectors Welded Wire reinforcing required to develop shear when studs are used Minimum area of 60ksi reinforcing as an alternative to WWF D PANEL Combined moment of inertia of deck-slab 4550 4550 4550 6x6 W4.0xW4.0 As = 0.080 in2/ft 129 209 129 Vn/Ω = 3.82 kip/ft ϕ Vn = 5.73 kip/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs kip/ft 15'-0" kip/ft Allowable superimposed live load capacity C PANELS Weight of deck-slab 36/4 2666 2359 2326 2326 Icr = 64.9 in4/ft Iu = 120.7 in4/ft Concrete + Deck = 45.7 psf (Icr+Iu)/2 = 92.8 in4/ft Attachment type to supports 14'-0" 122 195 70 112 2391 2204 2196 2190 2087 2181 2079 Vn/Ω = ϕ2071 V = Icr = 39.2 in4/ft Vn/Ω = 3.30 Mno/Ω= 31.6 kip-in/ft 9'-0" 9'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 4 Iu = 10'-0" 107.1 in10'-6" /ft 11'-0" 11'-6" ϕM = 48.4 kip-in/ft ϕ Vn = 4.76 no ASD & LRFD - Superimposed Load, W (psf) 480 424 377 337 303 273 247 224 204 186 170 155 142 768 679 604 540 484 436 395 358 326 297 271 248 228 142 Concrete + Deck = 44.0 psf Vertical Load Span(I(in) 4 +I )/2 = 8'-0" 73.2 in8'-6" /ft cr u ASD, W/Ω LRFD, ϕW L/360 no 13'-6" 134 214 78 124 2408 2214 2205 2200 2093 2190 2084 2076 Triple 14' - 4" 14' - 9" 15' - 7" 14'-6" 15'-0" N PANELS Attachment pattern for weld, PAFs of screws Vertical Load Span (in) ASD, W/Ω LRFD, ϕW ASD, W/Ω L/360 LRFD, ϕW 18 L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" 22 ArcPAF SpotBase WeldSteel 1/2" Effective ≥ 0.125"Dia PAF Base Steel #12 Screw Base Steel≥ ≥.25" .0385" PAF Base Steel ≥ 0.125" Concrete + Deck = #12 Screw Base Steel ≥ (I .0385" +I )/2 = 8'-6" Maximum Unshored Span (in) Triple Gage Single Double 11' - 4" 19 12' - 3" 13' - 10" 12' - 2" 18 12' - 7" 15' - 2" 12' - 11" 16 13' - 3" 16' - 7" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" B PANELS No load shown when greater than allowable superimposed live load Double 11' - 0" 11' - 9" 12' - 6" 8'-0" Vertical load span of deck 2W PANELS Maximum Clear Span without Shoring GENERAL INFORMATION Composite Deck-Slab Tables 1.12 Figure 1.12.1: SAMPLE OF COMPOSITE DECK TABLE ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 39 TABLE OF CONTENTS 1.13 Support Fastening Support Fastening A variety of fastening systems may be used to connect steel deck to the supporting steel members. The type of fastening system used depends on the required diaphragm shear capacity, uplift capacity, and the thickness of the supporting steel members. These fastening systems include arc spot welds, arc seam welds, headed stud anchors, self-drilling screws, and power-actuated fasteners (PAF). The strength of each fastener type is mathematically derived from specified standards and testing. Arc spot and arc seam welds do not have a mandatory minimum support member thickness. Experience has shown that a support thickness as thin as 10 gage is reasonable. Welders with light gage welding experience can weld steel deck to thinner gage supports. Steel headed stud anchors are subject to a minimum support member thickness in accordance with AISC 360. This requires that the headed stud anchor be a minimum of 2.5 times the thickness of the supporting beam flange unless the headed studs anchor is placed directly over the web. For ¾” diameter stud, the minimum flange thickness when the stud is not directly over the web is 0.3 inches. The shear strength for arc spot and arc seam welds is derived from the equations in Section E2.6 of AISI S100-2012. The strength for self-drilling screws and PAF is determined in accordance with the Steel Deck Institute Diaphragm Design Manual DDM03. The strengths for these fasteners are listed in the Weld and Shear Capacities Table (See figure 1.13.11 and Figure 1.13.12). The shear strength of steel headed stud anchors is determined in accordance with ASIC 360 Specification for Structural Steel Buildings. Self-drilling screws are suitable for use with supporting members from 0.0385 inches to ½”, depending on thread pitch and drill point configuration. The fastener manufacturer should be consulted to determine which screw is appropriate. The pull-out and pull-over capacities for fasteners are in accordance with Sections E4.4.1 and E4.4.2 of AISI S1002012. The pull-out for PAF’s should be obtained from the manufacturer’s data for the selected fastener. Power Actuated Fasteners (PAF) are selected based on a range of support thickness for a given fastener. Follow the PAF manufacturer’s support thickness recommendations. The fastener selection chart (See figure 1.13.1) provides a quick and easy guide to help select the appropriate fastening system for the support member thickness. Fastener Selection To ensure quality fastening to supports, the fastener (weld, screw, or PAF) must be compatible with the thickness of the steel support member. (See figure 1.13.1) Base Metal Thickness Figure 1.13.1: FASTENER SELECTION CHART Base Metal Thickness Fastener Minimum Maximum 0.400" min when not over web unlimited Arc Spot Weld* 0.135" unlimited 12-14 Self Drilling Screw** 0.0385" 0.210” 12-24 Self Drilling Screw** 0.125”* 0.500” Hilti X-HSN-24 High Shear Nail 1/8” 3/8” Hilti ENP19 L15 High Shear Nail 1/4” unlimited Pneutek SDK61075 Fastener 0.113” 0.155” Pneutex SDK63075 Fastener 0.155” 0.250” Pneutek K64062 and K64075 Fastener 0.187” 0.312” Pneutek K66062 and K66075 Fastener 0.312” unlimited 3/4" ϕ Shear Stud 0 *Below 10 gage is not recommended due to the difficulty of producing a good quality weld. 40 1/8 1/4 3/8 1/2 5/8 **Correct drill point must be selected for the base material thickness. Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS End Lapped Deck Condition 2” >emin Butted Deck Condition - 1/2” + unlimitted >emin 3W PANELS Minimum Fastener Edge Distance The minimum edge distance for fasteners used with ASC Steel Deck profiles has been verified through full-scale diaphragm shear testing. The minimum edge distance for self-drilling screws and PAFs is ½”. The minimum edge distance for arc spot and arc seam welds is ¾”. Edge distance is measured from the center of the fastener or the center of the radius of an arc spot or seam weld. (See figure 1.13.2) GENERAL INFORMATION Support Fastening 1.13 Butted Tight or Gap >emin >emin 2W PANELS de Figure 1.13.2: END LAP AND BUTTED DECK Welds used for composite deck-slab or non-composite deck-slab applications do not require touch up painting. Specifications should not require the weld to receive touch-up paint for decks with concrete fill. Arc spot and seam welds for ASC Steel Deck products are specified based on the effective diameter or length and width. This is approximately the diameter or width and length of a weld at the interface between the deck and supporting member. The effective weld size is less than the visible weld size and is verified through the development of weld qualifications and procedures. See AISI S100-2012 Section E2 for more information regarding weld design. Weld inspection, procedures, and qualifications should be in accordance with AWS D1.3 C PANELS Arc spot welds connecting deck less than 0.028 inches thick require weld washers in accordance with AWS D1.3. Weld washers are not recommended for thicker decks. (See figure 1.13.5) N PANELS Welded connections have some drawbacks compared to screws and PAF. Welds require skilled labor and have a relatively slow production rate. Additionally, welding cannot be performed in the rain or if standing water is present on the deck. Welding often results in burn marks visible from the underside of the deck and supporting members, which may be objectionable for some exposed deck conditions. Jobsite safety is of great concern as welding also creates a fire risk. Figure 1.13.4: ARC SPOT WELD (weld to support) B PANELS Arc Spot and Arc Seam Welds Traditionally, arc spot welds and arc seam welds are used to attach steel deck to supports. (See figures 1.13.3 and 1.13.4) Arc welds have high shear capacity, resulting in diaphragms with higher shear capacities than screws or power actuated fasteners (PAF). D PANEL de L www.ascsd.com ACUSTADEK® Figure 1.13.3: ARC SEAM WELD (weld to support) Figure 1.13.5: WELD WASHER Composite and Non-Composite Deck Catalog • February 2016 41 TABLE OF CONTENTS 1.13 Support Fastening Power-Actuated Fasteners, PAF Power-actuated fasteners (PAF) are an excellent fastening system. Commonly referred to as high shear nails or pins, they can be used to achieve mid to high range diaphragm shear capacities, depending on the fastener selected and the support thickness. The benefits of using PAFs is that they can be installed without skilled qualified welders, are efficient to install, do not pose a jobsite fire risk, and do not leave any burn marks associated with welding. This makes PAFs an attractive option for architecturally exposed steel deck. Hilti, Inc. Hilti, Inc.’s PAF system includes powder fired tools to install their high shear nails (HSN) and ENP fasteners. The operator of the powder-fired tools must have OSHA compliant safety training. Contact Hilti, Inc. for fastener installation instructions and for additional technical support relating to their fastening systems. (See figure 1.13.7 and 1.13.8) www.us.hilti.com 800-879-8000 Hilti Inc. Fasteners X-ENP-19 L15, X-HSN 24 A drawback of PAF systems is that it may be difficult for the design engineer to select the fastener size when designing with open-web steel joists because the thickness of the top chord may be unknown. Good practice would be to design the diaphragm with the minimum expected substrate steel thickness, and indicate a range of acceptable fasteners based on the thickness of the supporting steel member. The inspection process on the jobsite should be tasked with ensuring that the correct fastener is used based on the substrate thickness. Pneutek Pneutek’s PAF system uses a pneumatic actuated tool. This system does not use a powder charge to drive the fastener. Contact Pneutek for fastener installation instructions and for additional technical support relating to their fastening systems. (See figure 1.13.6) www.pneutek.com 800-431-8665 X-EDN-19 THQ12 X-EDK-22 THQ12 hnvs = 3/16” - 3/8” Steel Deck Panel Structural Steel Member X-ENP-19 L15 hnvs = 5/16” - 3/8” Steel Deck Panel Pneutek Fasteners SDK61075, SDK63075, K64062, K66075, K66056, K66062, K66075 Structural Steel Member Figure 1.13.7: HILTI X-ENP-19 Pneutek Fastener X-HSN 24 Head in Contact Steel Deck Panel hnvs = 5 — 9 mm Structural Steel Member Steel Deck Panel Structural Steel Member Figure 1.13.6: PNEUTEK K64062 42 Composite and Non-Composite Deck Catalog • February 2016 Figure 1.13.8: HILTI X-HSN 24 www.ascsd.com TABLE OF CONTENTS 2W PANELS Self-Drilling Screws Self-drilling screws are an excellent option for attaching deck to thin-gage metal supporting members. (See figure 1.13.10) Although diaphragms which are attached with screws tend to have a lower shear capacity than other support fastening systems, screws install quickly with lower skilled labor and do not leave any burn marks on the deck or supporting members. This makes them an attractive option for architecturally exposed steel deck. Self drilling screws may not be practical on heavier structural steel support members because it can be time consuming to drill through the steel deck panel into the supporting member. When installed, the driven screw penetrates both the steel deck panel and the supporting member; as a result, the screw points are visible from the underside of the supporting structure. 3W PANELS Headed Stud Anchor The headed shear stud anchor is a traditional method of attaching metal deck to supporting steel beams. (See figure 1.13.9) Shear studs are commonly used to develop composite steel beams. Headed shear stud anchors are an excellent way of transferring diaphragm shear forces from a collector beam into the composite deck-slab system. Shear studs replace an arc spot weld, PAF, or screws on a one to one basis. GENERAL INFORMATION Support Fastening 1.13 B PANELS N PANELS Self-Drilling Screw Steel Panel Steel Support C PANELS Figure 1.13.10: #12-24R1-1/4 SCREW Figure 1.13.9: HEADED STUD ANCHOR D PANEL ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 43 TABLE OF CONTENTS 1.13 Support Fastening Figure 1.13.11 Nominal Strength WELDING CAPACITIES Deck Panel Arc Spot (puddle) Weld (1/2 in effective diameter) Gage Arc Seam Weld (3/8 in x 1 in effective width & length) Shear (lbs) Tensile (lbs) Shear (lbs) BH, NH 22 20 18 16 2416 3364 5701 7263 2310 2755 3618 4463 3873 4688 6344 8065 2WH, 3WxH 22 21 20 19 18 16 2323 2886 3212 4486 5525 7172 2243 2541 2689 3200 3561 4408 3752 4293 4565 5531 6231 7948 BHF, NHF 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 8608 8836 8836 8836 8836 8836 8836 8836 8836 5290 6019 6862 6078 6853 7850 6935 7850 8875 9851 11521 13392 11660 13376 15298 13534 15298 17271 2WHF, 3WxHF 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 8509 8836 8836 8836 8836 8836 8836 8836 8836 5229 5960 6788 6026 6788 7782 6870 7782 8805 9717 11383 13250 11537 13250 15168 13408 15168 17138 Safety and Resistance Factors for Welds for Conditions other than Diaphragm Shear Shear Tension Ω Φ Ω Φ Arc Spot Weld Arc Spot Weld Arc Spot Weld Arc Spot Weld 2.80 3.05 2.55 2.20 0.55 0.50 0.60 0.70 2.50 0.60 Arc Seam Weld 2.55 0.60 Calculated in Accordance with AISI S100-2012 44 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Figure 1.13.12 Nominal Strength MECHANICAL FASTENER CAPACITIES Screws unlimited unlimited 0.375 0.375 0.250 unlimited 0.312 0.232 22 1402 1624 1508 1508 1841 1735 1728 1546 20 1683 1938 1800 1800 2258 2216 1977 1833 18 2241 2549 2367 2367 3132 3009 2417 2378 16 2803 3149 2924 2924 4076 3686 2812 2896 22 1359 1577 1464 1464 1780 1655 1689 1502 21 1547 1787 1659 1659 2055 1993 1860 1695 20 1641 1891 1756 1756 2195 2149 1941 1790 19 1969 2253 2092 2092 2698 2642 2210 2116 18 2203 2508 2329 2329 3071 2960 2389 2342 16 2766 3109 2887 2887 4011 3644 2787 2862 20/20 3370 3737 3470 3470 5092 4294 3176 3386 20/18 3886 4258 3953 3953 6071 4800 3485 3804 20/16 4448 4810 4466 4466 7201 5314 3801 4229 18/20 3928 4300 3992 3992 6154 4840 3509 3837 18/18 4444 4806 4462 4462 7191 5310 3799 4225 18/16 5006 5342 4960 4960 8383 5793 4099 4619 16/20 4491 4851 4504 4504 7288 5351 3824 4259 16/18 5006 5342 4960 4960 8383 5793 4099 4619 16/16 5569 5862 5444 5444 9639 6251 4385 4982 20/20 3328 3694 3430 3430 5014 4250 3150 3350 20/18 3844 4215 3914 3914 5989 4760 3460 3770 20/16 4406 4769 4429 4429 7114 5277 3778 4198 18/20 3891 4262 3958 3958 6081 4804 3487 3807 18/18 4406 4769 4429 4429 7114 5277 3778 4198 18/16 4969 5307 4928 4928 8302 5762 4079 4594 16/20 4453 4815 4471 4471 7211 5318 3804 4232 16/18 4969 5307 4928 4928 8302 5762 4079 4594 16/16 5531 5828 5412 5412 9553 6221 4367 4958 D PANEL Deck Gage SDK61075 Max SDK63075 0.155 K64062 K64075 0.232 K66062 K66075 0.312 X-EDNK22 THQ12 0.125 X-HSN 24 0.125 X-ENP-19 L15 0.125 C PANELS 2WHF, 3WxHF 0.250 N PANELS BHF, NHF 0.0385 B PANELS 2WH, 3WxH Min 2W PANELS BH, NH Pneutek # 12, #14 Self Drill Deck Profile Nominal Shear Strength (lbs) 3W PANELS Supporting Framing Steel Thickness (in) Hilti GENERAL INFORMATION Support Fastening 1.13 Calculated in Accordance with the SDI DDM03 ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 45 TABLE OF CONTENTS 1.14 Side Seam Fastening Side Seam Attachment The side seam attachment for composite floor deck has a small influence on diaphragm shear capacity, but is critical for holding the seam together during the concrete pour. The side seam attachment creates a positive connection, limiting differential movement between the sheets of deck under out-of-plane loads during concrete placement. The common side seam attachment systems are the Triple Button Punch™, traditional button punch, top seam weld, and DeltaGrip® system for standing seam interlock side seams. Self-drilling screws are used for nestable side seams. The two common types of side seams are the standing seam interlock and the nestable side seam (See figure 1.14.1). STANDING SEAM (ALL) Triple Button Punch The Triple Button Punch™ is the latest innovation in reliable side seam connections for standing seam side laps for composite steel deck. (See figure 1.14.2) For architecturally exposed deck, the Triple Button Punch system is the best option because there are no penetrating holes that can leak concrete, and no unsightly burn marks typically associated with welded connections. This connection is installed using ASC Steel Deck's DeltaGrip tool with the triple button punch die set. The triple button punch is more effective than a traditional button punch because the three dimpled connections are tightly seated using the DeltaGrip pneumatic tool. The DelatGrip tool produces consistent, repeatable punches that are not subject to operator fatigue or punch depth settings that cause quality problems with traditional hand operated button punch tools. NESTABLE (B & N) STANDING SEAM SCREWABLE SIDELAP (2W) Figure 1.14.1: STANDING SEAM AND NESTABLE DIAGRAM Figure 1.14.2: TRIPLE BUTTON PUNCH Traditional Button Punch The traditional button punch attachment is used to connect standing seam side seams by creating a single dimpled clinch connection. (See figure 1.14.3) The quality of a button punch which has been installed with a hand-operated tool is dependent on the operator and the depth of the particular punching tool. A “good” button punch should not become disengaged when a person modestly jumps on the adjacent sheet of deck. SAMPLE BUTTON PUNCH TOOL 46 Figure 1.14.3: BUTTON PUNCH SIDE LAPS Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Figure 1.14.4: SIDE SEAM SELF-DRILLING SCREW (Nestable Sidelap) Figure 1.14.6: SIDE SEAM SELF-DRILLING SCREW (Screwable Sidelap) Top Seam Weld Top seam welds are the least desirable method to connect standing seam composite deck together. (See figure 1.14.5) The top seam welds are slow to install, require skilled welders, and contribute very little to the strength of the composite deck system. Top seam welds connect the standing seam deck side seams by welding the three layers of steel deck together. This is done after the hem is crimped using a hand or pneumatically operated crimping tool. Top seam welding is a slow process requiring skilled welders, leading to increased installation cost. The welding creates burn marks on the underside of the deck and occasional burn-through holes. Top seam welds are not recommended for architecturally exposed steel deck. Weld inspection, procedures, and qualifications should be in accordance with AWS D1.3. DeltaGrip® The DeltaGrip system was developed in 2003 to reduce the installed costs of high shear roof deck diaphragms by eliminating the costly top seam weld. The DeltaGrip connection has also been proven to be an effective side seam connection for composite steel deck, keeping the deck from separating during concrete placement. This revolutionary clinching system punches three triangular tabs though the standing seam interlock side seam. This interlock creates the equivalent strength of a time consuming top seam weld with the rapid action of a pneumatically powered DeltaGrip tool. High-quality DeltaGrip connections can be installed with low-skill labor compared to the skilled welders required to make top seam welds. Figure 1.14.5: TOP SEAM WELD Figure 1.14.7: DELTAGRIP PUNCH 2W PANELS Screwable Sidelap Self-drilling screws are used to attach standing seam screwable sidelap composite deck. (See figure 1.14.6) The screws can be easily installed with low-skill labor using screw guns that are readily available. The screws do not leave burn marks associated with welding, but the screw points do protrude through the underside of the steel deck. As a result, screws may not be acceptable for some architecturally exposed steel deck. 3W PANELS Self-Drilling Screws Self-drilling screws are used to attach standing seam screwable sidelap steel deck. (See figure 1.14.4) Screws can be easily installed with low-skill labor using screw guns that are readily available. Screws do not leave burn marks associated with welding, but the screw points do protrude through the underside of the steel deck. As a result, screws may not be acceptable for some architecturally exposed steel deck. GENERAL INFORMATION Side Seam Fastening 1.14 B PANELS N PANELS C PANELS D PANEL Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® www.ascsd.com 47 TABLE OF CONTENTS 1.15 Edge Form Edge Form Edge form is an integral part of a composite or noncomposite deck installation. The edge form provides containment of the concrete at the perimeter of the composite deck-slab system and around openings. Edge form also provides a screed at the edge to help maintain slab thickness. Edge forms may be manufactured from bent plate, cold-formed sheet steel, and hot roll steel angles or channels. ASC Steel Deck manufactures coldformed sheet steel flashings used for edge forms and other flashing conditions. Section 1.17 shows typical installation conditions for common flashing types. Edge Form Flashings Galvanized steel edge form flashings are custom manufactured by ASC Steel Deck to meet project requirements. The flashings are formed from ASTM A653 SS Grade 33 minimum galvanized steel sheets. Flashings are available in most common structural shapes in 7 gages. (See figures 1.15.1 and 1.15.2) The standard length flashing is 10’-0”, shorter lengths available upon request. The minimum width of any stiffener or flat cross section is ¾”. For Hat and Channel shapes, the web width must be at least ¾” wider than the flange width. Design of Edge Form Edge forms may be rationally designed to support concrete and construction loads using the methods in the SDI Floor Deck Design Manual based on engineering mechanics and confirmatory testing. The SDI edge form table provided in figure 1.15.3 provides an easy to use design aid without the need to detailed calculations for common edge form conditions. FLASHING THICKNESS BY GAGE Gage Base Steel Thickness 22 20 18 16 14 12 10 0.0290 0.0350 0.0470 0.0590 0.0700 0.1050 0.1350 Figure 1.15.1 ≥3⁄4" ≥3⁄4" MINIMUM FLAT WIDTH MINIMUM STIFFENER WIDTH 1" STRIP FILLER PLATE (10" Max) ≥3⁄4" ANGLE ANGLE WITH STIFFENER ZEE F F ≥F+3⁄4" ≥F+3⁄4" HAT CHANNEL Figure 1.15.2 48 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Figure 1.15.3: Pour stop gage selection table, based on overhang and slab depth. (as published in ANSI/SDI C-2011) GENERAL INFORMATION Edge Form1.15 Pour Stop Overhang 0" 1" 2" 3" 4" 5" 6" 7" 8" 9" 10" 11" 12" 4.00 4.25 4.50 4.75 5.00 5.25 5.50 5.75 6.00 6.25 6.50 6.75 7.00 7.25 7.50 7.75 8.00 8.25 8.50 8.75 9.00 9.25 9.50 9.75 10.00 10.25 10.50 10.75 11.00 11.25 11.50 11.75 12.00 20 20 20 20 20 20 20 20 18 18 18 18 18 16 16 16 14 14 14 14 14 12 12 12 12 12 12 12 12 12 10 10 10 20 20 20 20 20 18 18 18 18 18 16 16 16 16 14 14 14 14 12 12 12 12 12 12 12 12 12 10 10 10 10 10 10 20 20 20 18 18 18 18 16 16 16 16 14 14 14 14 14 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 20 18 18 18 18 16 16 16 16 14 14 14 14 14 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 18 18 18 16 16 16 16 14 14 14 14 14 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 18 16 16 16 16 14 14 14 14 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 10 16 16 16 14 14 14 14 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 14 14 14 14 14 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 12 12 12 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 10 12 12 12 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 3W PANELS Slab Depth 2W PANELS B PANELS 1/ 2” N PANELS 1” Fillet Welds @ 12” O.C. Slab Depth C PANELS Pour Stop Edge Form Detail 1. Normal weight concrete (150 pcf). 2” D PANEL The above Selection Table is based on the following criteria: Overhang FD14 Edge Form detail 2. Horizontal and vertical Deflection is limited to 1/4” maximum for concrete dead load 3. Design stress is limited to 20 ksi for concrete dead load temporarily increased by one-third for the construction live load of 20 psf. 4. Pour Stop Selection Table does not consider the effect of the performance, deflection, or rotation of the pour stop support which may include both the supporting composite deck and/or the frame. ACUSTADEK® 5. Vertical leg return lip is recommended for all types (gages). 6. This selection is not meant to replace the judgement of experienced Structural Engineers and shall be considered as a reference only. 7. SDI reserves the right to change any information in this section without notice. www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 49 TABLE OF CONTENTS 1.16 Accessories ASC Steel Deck offers a variety of accessories to complement our steel deck offer. These include flashings, sump pans, weld washers, profile cut top (small void) and bottom (large void) neoprene foam, and galvanized steel closures. When accessories are called for in the specifications, the location must be clearly shown on the structural and architectural drawings. Specifications which call for the use of profile cut closures where walls meet the metal deck may lead to unnecessary construction costs if they are only needed at exterior walls or specific interior locations. B36 DECK NEOPRENE AND METAL CLOSURES B36 Large Neoprene B36 Large Metal Profile Cut Neoprene Closures Neoprene closures may be used on the top and bottom of the steel deck to reduce vapor, moisture, and air from infiltrating into the building roof or floor assembly. These are die-cut from black closed cell neoprene foam. The foam is manufactured in accordance with ASTM D-1056 and passes the FM-VSS No. 302, UL 94HBF, and UL 94 HF1 flammability tests. Profile Cut Metal Closures Metal closures may be used to control animal nesting within the building structure. Metal closures may be used in combination with neoprene closures. Metal closures with calking can also be used to reduce noise infiltration as part of an acoustically engineered system. The metal closures are stamped out of minimum 22 gage galvanized sheet steel. 2WH NEOPRENE AND METAL CLOSURES Figure 1.16.1 N32 DECK NEOPRENE AND METAL CLOSURES 2W Neoprene N32 Large Neoprene Figure 1.16.4 N32 Large Metal 3WxH NEOPRENE AND METAL CLOSURES 2W Metal Figure 1.16.2 Weld Washers 14 gauge x 3⁄8” diameter hole for welded attachment of C1.432. Variable Gauge x 3⁄8” diameter hole for welded attachment of C0.9-32. Weld washers are for use with 26 and 24 gage C1.4-32 and C0.9-32 only. Do not use weld washers Raised Edge Weld Washer on 22 gage or heavier steel decks. 3WxH Neoprene 3WxH Metal Figure 1.16.5 1” 3/4” Weld Washer Curved 14 Gage x 3⁄8” dia. hole for welded attachment of C1.4-32 (CF13⁄8) DEEP DECK NEOPRENE CLOSURES 14 gauge X 3/8” dia. hole for welded attachment of CF 7/8”. RD39 Raised Edge Weld Washers 14 Gage x 3⁄8” dia. hole for welded attachment of C0.9-32 (CF7⁄8) 4.5D Neoprene Figure 1.16.3 50 Composite and Non-Composite Deck Catalog • February 2016 6D Neoprene 7.5D Neoprene Figure 1.16.6 www.ascsd.com TABLE OF CONTENTS 2W PANELS Minimum Welded Wire or Rebar when Specified 3W PANELS Details Composite deck-slab systems are not complete without edge form and flashings to contain the concrete during the pour. These common details are an important part of the system. Edge forms provide both concrete containment and establish one point of depth control for the concrete. GENERAL INFORMATION Typical Details 1.17 Cell Closure Edge Form eq eq B PANELS Figure 1.17.1: TYPICAL PLACEMENT OF TEMPERATURE & SHRINKAGE REINFORCEMENT Edge Form N PANELS Figure 1.17.3: SINGLE PIECE EDGE FROM PERPENDICULAR TO DECK ON WIDE FLANGE BEAM Edge Form C PANELS Cell Closure D PANEL Figure 1.17.2: SINGLE PIECE EDGE FROM PARALLEL TO DECK ON WIDE FLANGE BEAM Figure 1.17.4: TWO PIECE EDGE FORM WITH DECK CANTILEVER ON WIDE FLANGE BEAM ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 51 TABLE OF CONTENTS 1.17 Typical Details Field Cut Deck Figure 1.17.5: DECK PARALLEL TO WIDE FLANGE BEAM Figure 1.17.8: DECK PARALLEL TO WIDE FLANGE BEAM CUT WITH ZEE FLASHING TO ACCOMMODATE DECK MODULE Field Cut Deck Cell Closure Figure 1.17.6: DECK PARALLEL TO WIDE FLANGE BEAM CUT TO ACCOMMODATE DECK MODULE Filler Plates Figure 1.17.9: DECK TRANSITION ON WIDE FLANGE BEAM or Figure 1.17.7: DECK PARALLEL TO WIDE FLANGE BEAM WITH FILLER PLATES 52 Z Closure Figure 1.17.10: DECK PERPENDICULAR TO WIDE FLANGE BEAM Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Edge Form Hat or Channel Section GENERAL INFORMATION Typical Details 1.17 3W PANELS Figure 1.17.11: CONCRETE OR CMU WALL LEGER DECK PERPENDICULAR 2W PANELS Figure 1.17.14: SINGLE PIECE EDGE FROM PARALLEL TO DECK ON OPEN WEB JOIST GIRDER Edge Form B PANELS Cell Closure N PANELS Figure 1.17.15: TWO PIECE EDGE FORM WITH DECK CANTILEVER ON WIDE FLANGE BEAM C PANELS Figure 1.17.12: CONCRETE OR CMU WALL LEGER DECK PARALLEL D PANEL Figure 1.17.13: CONCRETE OR CMU WALL WITH EMBED PERPENDICULAR www.ascsd.com ACUSTADEK® HAT SECTION ONLY REQUIRED AT GIRDERS THAT ARE AXIAL COLLECTORS FOR DIAPHRAGM Figure 1.17.16: DECK ON OPEN WEB STEEL JOISTS AND OPEN WEB STEEL JOIST GIRDER Composite and Non-Composite Deck Catalog • February 2016 53 TABLE OF CONTENTS 1.17 Typical Details Column Flashings Columns may require deck support angles depending on web support. Smaller columns often do not require deck support angles because there are no unsupported webs as shown in Figure 1.17.17. Large columns will create a condition in which one or more webs are unsupported, as shown in Figure 1.17.18. When the webs are unsupported, deck support angles are required to limit localized deflections during concrete placement. The Detail in Figure 1.17.18 is a common example of how deck may be supported when required. Using the thinnest support angles practical, when installed as shown, makes fitting and attaching the deck easier. DECK NOT SHOWN FOR CLARITY DECK NOT SHOWN FOR CLARITY Deck Support Angles Deck Support Required When These Webs are Unsupported by Beams Deck Support Not Required When These Webs are Supported by Beams Deck Support Angles Figure 1.17.17: COLUMN DETAIL NOT REQUIRING DECK SUPPORT ANGLES 54 Figure 1.17.18: COLUMN DETAIL REQUIRING DECK SUPPORT ANGLES Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Composite Deck-Slab 1.18 Tables General Requirements 2W PANELS B PANELS ACUSTADEK® 55 D PANEL Composite and Non-Composite Deck Catalog • February 2016 C PANELS Deck as a form 1. Shoring spans are based on the load combinations and bending strength requirements of ANSI/SDI C-2011, which include the weight of the deck. The loading includes the weight of the deck, concrete and 20psf uniform construction load, or 150 lbs/ ft line load at mid span. In addition to the loads in accordance with ANSI/SDI C-2011, 3psf is added for normal weight concrete, and 2 psf is added for light weight concrete to account for pounding due to deck deflection between supporting members. 2. The theoretical deflection is limited to L/180, but not to exceed 3/4 inch for the weight of concrete and steel deck only. 3. Reactions at supports shall not be exceeded. The shoring span may be limited by the reactions at supports in some conditions. For support reactions exceeding the reaction tables, the reactions shall be based on the web crippling of the steel deck using the flat width (h), angle to support (θ) and bend radius (r) presented in the reactions tables in accordance with the provisions of AISI S100-2012. 4. Conditions exceeding the scope of the tables, such as cantilever spans, may be determined in accordance with ANSI/SDI C-2011 and submitted to the building official for approval. N PANELS www.ascsd.com neutral axis of gross or effective section sg Minimum section modulus for gross section r radius of gyration Ae Effective are for compression se- Negative effective section modulus se+ Positive effective section modulus Ie+ Positive effective moment of inertia Ie- Negative effective moment of inertia I+ Positive effective moment of inertia for determining deflection I- Negative effective moment of inertia for determining deflection 11. Definition of symbols for reactions h Flat width of web R/Ω ASD available reaction capacity at support based on web crippling ϕR LRFD available reaction capacity at support based on web crippling r bend radius of web/flange transition θ angle relative to the support of the web 12. Definition for headed shear stud anchors Qn Nominal shear capacity for one welded headed shear studs anchor Qn/Ω ASD available shear capacity for one welded headed shear studs anchor ϕQn LRFD available shear capacity for one welded headed shear studs anchor 3W PANELS General Notes 1. The general notes apply to the entire catalog. 2. Composite steel deck is manufactured from galvanized steel conforming to ASTM A653 SS grade 50 or bare steel conforming to ASTM A1008 SS grade 50. 3. The concrete slabs depth in the tables is measured for the bottom of deck to the top of concrete. 4. The vertical load span is the clear span between supporting members. 5. Superimposed load is the load which can be applied to the composite deck in addition to the weight of the steel deck and concrete. 6. No uniform service load, based on an L/360 deflection limit, is shown when the load is greater than the allowable superimposed load. 7. For composite steel deck assemblies which exceed the scope of the table, the performance may be determined in accordance with ANSI/SDI C-2011. a. For 2WH-36 and 2WHF-36 the embossment shape is Type 1 with an embossment factor, K = 1.0, reference Eq. A2-8 in ANSI/SDI C-2011 b. For 3WxH-36 and 3WxHF-36 the embossment shape is Type 2 with an embossment factor, K = 1.0, reference Eq. A2-8 in ANSI/SDI C-2011 c. For BH-36 and BHF-36 the embossment shape is Type 1 with an embossment factor, K = 1.0, reference Eq. A2-8 in ANSI/SDI C-2011 d. For NH-32 and NHF-32 the embossment shape is Type 2 with an embossment factor, K = 1.0, reference Eq. A2-8 in ANSI/SDI C-2011 8. Load tables are based on non-cellular version of profile. The addition of the pan (bottom plate) of cellular deck increases steel area and inherently increases the performance of the composite deck assembly. Using non-cellular design values in tables is therefore conservative. 9. Definition of symbols for composite deck As Area of reinforcing steel Icr Cracked moment of inertia Iu Un-cracked moment of inertia (Icr+Iu)/2 Moment of inertia for determining deflection under service load L Vertical load clear span Mno/Ω ASD available flexural moment Vn/Ω ASD available vertical shear ϕMno LRFD available flexural moment ϕVn LRFD available vertical shear ϕSn LRFD available diaphragm shear PAF Power actuated fastener W/Ω ASD available superimposed load capacity ϕW LRFD available superimposed load capacity 10. Definition of symbols for panel properties Ag Gross Area of steel deck t Design base steel thickness of steel deck Fy Yield strength of steel Fu Tensile strength of steel Ig Moment of inertia of gross section yb Distance form extreme bottom fiber to GENERAL INFORMATION TABLE OF CONTENTS 1.18 Composite Deck-Slab Tables General Requirements Concrete and minimum reinforcing 1. The minimum 28-day compressive strength for structural concrete shall be 3,000 psi (20.68 MPa). The appropriate concrete density (normal weight or structural lightweight) is indicated in the tables. 2. Minimum reinforcing may be provided by reinforcing steel, welded wire fabric, or fibers in accordance with of the following: a. Minimum steel reinforcing shall be equal to 0.00075 times the area of the concrete above the steel deck, but not less than 6 x 6 W1.4 x W1.4 welded wire fabric with a 60,000psi minimum tensile strength complying with ASTM A1064. b. Concrete fibers in accordance with ANSI/SDI C-2011 section 13.a.1 or 13.a.2. Attachment of composite steel deck to supports 1. To develop the shear capacity in the tables, the deck shall be attached to the supports with the specified fastener pattern. 2. Spacing of welds or fasteners running parallel with the deck shall not exceed 36 inches on center. 3. Power actuated fasteners shall be installed per manufacture's instructions 4. Welds and fasteners to the supports shall be as follows: a. Welds i. Welds shall be have a minimum of 60ksi filler metal. For shielded metal arc welding, a minimum E60xx electrode should be used. ii. Arc spot welds shall have a minimum ½ inch effective diameter and not less than a 5/8 inch visible diameter iii. Arc seam welds shall have a minimum 3⁄8 inch x 1 inch effective size, and may be substituted for ½ inch effective diameter arc spot welds b. Power actuated fasteners (PAF) in support steel ≥ .25 inch thick shall be: i. Hilti X-ENP19 ii. Pneutek K64 iii. Pneutek K66 c. Power actuated fasteners (PAF) in support steel ≥ 0.109 inch thick shall be: i. Hilti X-HSN 24 ii. Pneutek K63 iii. Pneutek K61 d. Self-drilling screws in support steel ≥ .034 inch thick shall be: i. #12 Self Drilling-Screw in accordance with SAE J78 e. Minimum Edge Distance i. Steel deck may be butted at supports or end lapped. The standard end lap is a 2-inch overlap with a tolerance of +/-1/2 inch. The minimum 1-1/2 inch overlap (2-inch standard less 56 ½-inch tolerance) is required. Overlaps greater than 2-1/2 inches do not affect diaphragm performance, but is more difficult to install. ii. The minimum edge distance for selfdrilling screws and power driven fasteners (pins/nails) is ½ inch. 5. The minimum edge distance for welds is ¾ inch measured from the center of the arc spot weld and the center of the end radius of the arc seam weld. >emin Butted Tight or Gap >emin Figure 1.18.1: BUTTED DECK CONDITION 2” +- 1/2” unlimitted >emin >emin Figure 1.18.2: END LAPPED DECK CONDITION Side seam attachment between deck panels 1. The minimum side seam attachment is a button punch at 36 inches on center. 2. Triple Button Punches, DeltaGrip side seam connections, arc top seam welds, or self-drilling screws may be substituted on a one to one basis for button punches. 3. The minimum edge distance for side lap screws is 1.5 times the nominal diameter of the screw. Diaphragm shear attached with arc spot welds, power actuated fasteners, or self-drilling screws. 1. For composite steel deck assemblies which exceed the scope of the tables, the diaphragm shear performance may be determined in accordance with the SDI DDM03 referenced in ANSI/SDI C-2011 2. Diaphragms with concrete fill have a flexibility factor, f < 0.5 micro inches per lb equal to a shear stiffness, G’ > 2000kip/inch Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Composite Deck-Slab 1.18 Tables General Requirements ASD Qn/R LRFD ϕQn 2WH-36, 2WHF-36, & 2WHF-36A, 3WxH-36, 3WxHF-36, & 3WxHF-36A 10.3 kips 15.5 kips BH-36, BHF-36, & BHF-36A NH-32, NHF-32, & NHF-32A 8.8 kips 13.2 kips DECK TYPES 145 pcf Normal Weight Concrete and 110 pcf Light Weight Concrete Figure 1.18.3 1 ≥½˝ ≥1½˝ ≥½˝ Reinforcing Mesh or Bar Reinforcing Mesh or Bar Concrete Thickness Concrete Thickness Deck Height ≥1½˝ ≥½˝ ≥1½˝ ≥½˝ ≥1½˝ Shear Steel Stud Deck Shear Steel Stud Deck Deck Parallel to Beam Reinforcing Mesh or Bar Reinforcing Mesh or Bar Deck Height B PANELS Concrete Thickness Concrete Thickness Deck Height Shear Steel Stud Deck Shear Steel Stud Deck Deck May Extend as Shown Deck May Extend as Shown Deck Height N PANELS Deck Perpendicular to Beam Figure 1.18.4 ACUSTADEK® Composite and Non-Composite Deck Catalog • February 2016 D PANEL 12. For diaphragm shear of composite steel deck assemblies attached with welded shear studs which exceed the scope of the tables, the diaphragm shear may be determined in accordance with the provision of ACI 318 and AISC 360 as follows. a. The diaphragm shear shall be the lesser of the capacity of the reinforced concrete and the capacity of the welded shear studs to transfer the shear from the supporting member to the reinforced concrete section. b. Reinforced concrete shear shall be determined in accordance with the requirements of ACI 318 using the concrete thickness above the steel deck. c. The welded shear stud strength shall be determined in accordance with AISC 360. C PANELS www.ascsd.com Shear Capacity1 2W PANELS Diaphragm shear with welded headed shear stud anchors 1. Concrete shear reinforcing steel shall be provided that meets the minimum specified reinforcing area, (As), in the table based on suggested welded wire reinforcing size. Reinforcing shall have minimum yield strength of 60,000psi and meet the requirements of ACI 318 for standard reinforcing bars or WRI standard welded wire reinforcement. 2. To achieve tabulated diaphragm shears, the welded stud shear connectors are only required at locations in which diaphragm shear is being transferred between the composite deck slab and supporting members. Intermediate support members may be attached with welds, screws or PAF’s (power actuated fasteners) 3. Intermediate ribs of the steel deck not attached with welded stud shear connectors shall be fastened to the supporting member with arc spot welds, selfdrilling screws, or power actuated fasteners. 4. The welded stud shear connector strength assumes the weak position in the deck flute. Reference AISC 360-10 Commentary and Figure C-I8.1. 5. Tabular values for shear strength of concrete diaphragm above deck is in accordance with ACI 318-14 based on a resistance factor ϕ = 0.75. Refer to ACI 318 for additional requirements to be considered in seismic design. 6. Welded stud shear connectors shall extend 1½” above the top of the steel deck and shall have a minimum of ½” concrete cover above the top of the installed connector. Reference AISC 360-10 Section I3.2c. 7. The supporting member flange shall not be less than 0.3 inches thick unless the welded stud shear connector is welded over the web of the supporting member. Reference AISC 360-10 Section I8.1. 8. The maximum center-to-center spacing of welded stud shear connectors shall not exceed 8 times the depth of concrete above the deck or 36” per AISC 360-10 Section I8.2d. 9. Concrete reinforcement details shall be in accordance with ACI318. 10. For local shear transfer in the field of the diaphragm, ¾ inch diameter welded stud shear connectors shall be determined in accordance with AISC 360. The following shear capacities are for 2 inches of concrete cover above the steel deck and may be used conservatively for all thicknesses greater than 2 inches. 11. See figure 1.18.4 for typical details ⁄4" Steel Headed Stud Anchors 3 3W PANELS 3. Spacing of welds or fasteners transferring shear between the composite steel deck and supporting structures shall be based on the shear demand and the weld or fastener shear resistance. fastener spacing (ft) = weld or fastener capacity (lbs) / shear demand (lbs/ft) 4. Resistance and safety factors for diaphragm shear, ϕ = 0.5 GENERAL INFORMATION 57 TABLE OF CONTENTS 2.1 3WxH-36 4½" 12" 3" 36/4 36" 4½" 3WxH-36 Profile 36/4 Attachment Pattern 2 0.060 1 1 3/16 3Wx Series Embossment Panel Properties Gage Weight 22 21 20 19 18 16 w psf 1.70 1.92 2.09 2.43 2.76 3.43 Compression Gage 22 21 20 19 18 16 Area Ae in2/ft 0.309 0.362 0.414 0.532 0.651 0.887 Base Metal Thickness Yield Strength t in 0.0290 0.0330 0.0359 0.0420 0.0478 0.0598 Fy ksi 50 50 50 50 50 50 Tensile Strength Area Fu ksi 65 65 65 65 65 65 Ag in2/ft 0.504 0.556 0.605 0.708 0.806 1.008 Effective Section Modulus at Fy Bending Distance to Section N.A. from Section Modulus Bottom Modulus Se+ yb Sein3/ft in in3/ft 0.392 1.33 0.404 0.452 1.36 0.465 0.510 1.39 0.524 0.636 1.43 0.654 0.761 1.46 0.781 0.984 1.49 0.982 Gage 22 21 20 19 18 16 58 Condition 1" End 296 Interior 522 End 379 Interior 667 End 424 Interior 746 End 600 Interior 1054 End 743 Interior 1305 End 1143 Interior 2008 Web Crippling Constraints Ig in4/ft 0.770 0.850 0.927 1.083 1.233 1.540 yb in 1.48 1.48 1.48 1.48 1.49 1.49 Sg in3/ft 0.497 0.548 0.595 0.695 0.789 0.984 Radius of Gyration r in 1.236 1.236 1.236 1.236 1.236 1.236 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 1.63 1.61 1.59 1.55 1.52 1.50 Reactions at Supports (plf) Based on Web Crippling Allowable (Rn/Ω) 2" 4" 368 471 630 783 470 598 801 990 524 666 893 1101 737 930 1252 1532 908 1141 1542 1878 1383 1723 2350 2834 h=2.16" Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Moment of Inertia Ie+ in4/ft 0.727 0.823 0.910 1.083 1.233 1.540 Bearing Length of Webs 6" 550 900 697 1135 775 1261 1078 1747 1320 2136 1983 3206 1" 452 776 580 993 649 1110 918 1568 1137 1941 1749 2986 r=0.125" Composite and Non-Composite Deck Catalog • February 2016 Moment of Inertia Ie in4/ft 0.720 0.813 0.900 1.073 1.230 1.540 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 0.741 0.832 0.916 1.083 1.233 1.540 Factored (ΦRn) 2" 4" 564 721 937 1164 719 915 1191 1472 802 1020 1329 1638 1127 1423 1863 2280 1389 1746 2294 2794 2116 2636 3495 4216 θ=54.4º Iin4/ft 0.737 0.826 0.909 1.077 1.231 1.540 6" 842 1338 1066 1688 1186 1876 1650 2599 2020 3178 3034 4768 www.ascsd.com TABLE OF CONTENTS 4½" 12" 3" 36/4 4½" 36" GENERAL INFORMATION 3WxHF-36 2.2 36/4 Attachment Pattern 3WxHF-36 Profile Gage Gage Area Ag in2/ft 1.054 1.193 1.344 1.253 1.392 1.543 1.45 1.593 1.744 Effective Section Modulus at Fy Bending Distance to N.A. from Bottom yb in 0.75 0.66 0.61 0.98 0.88 0.80 1.11 1.02 0.95 Section Modulus Sein3/ft 0.645 0.674 0.701 0.844 0.879 0.910 1.047 1.084 1.119 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 1.42 1.23 1.04 1.49 1.34 1.19 1.53 1.40 1.28 Moment of Inertia Ie + in4/ft 1.506 1.582 1.640 1.930 2.056 2.170 2.306 2.454 2.592 Moment of Inertia I ein4/ft 1.186 1.363 1.512 1.484 1.693 1.868 1.790 2.012 2.214 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 1.518 1.601 1.669 1.931 2.057 2.171 2.307 2.455 2.593 Iin4/ft 1.305 1.455 1.584 1.633 1.815 1.969 1.963 2.160 2.341 C PANELS Section Modulus Se+ in3/ft 0.538 0.540 0.562 0.875 0.878 0.875 1.175 1.194 1.211 Radius of Gyration r in 1.209 1.172 1.133 1.242 1.216 1.186 1.262 1.242 1.220 N PANELS 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Area Ae in2/ft 0.481 0.551 0.650 0.691 0.761 0.860 0.923 0.997 1.095 Tensile Strength Fu ksi 65 65 65 65 65 65 65 65 65 B PANELS Compression Base Metal Thickness Yield Strength t Fy in ksi 0.035 / 0.036 50 0.035 / 0.047 50 0.035 / 0.059 50 0.047 / 0.036 50 0.047 / 0.047 50 0.047 / 0.059 50 0.059 / 0.036 50 0.059 / 0.047 50 0.059 / 0.059 50 2W PANELS 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Weight w psf 3.69 4.16 4.68 4.35 4.83 5.35 5.03 5.51 6.03 Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Ig yb Sg in4/ft in in3/ft 1.542 0.91 0.712 1.640 0.81 0.723 1.727 0.74 0.732 1.932 1.02 0.934 2.058 0.93 0.949 2.172 0.85 0.962 2.309 1.1 1.155 2.457 1.01 1.174 2.595 0.94 1.191 3W PANELS Panel Properties D PANEL ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 59 TABLE OF CONTENTS 2.3 3WxHF-36 Cellular Composite Deck Normal Weight Concrete (145 pcf) Maximum Unshored Spans 3WxHF-36 Cellular Shoring Table Total Slab Depth (in) 5 6 6 1/2 1 Hour Fire Rating 7 1/2 2 Hour Fire Rating Volume cy/100sf 1.080 1.389 1.543 1.852 8 1/4 3 Hour Fire Rating 2.083 Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 145 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 45.9 12' - 2" 12' - 4" 46.4 12' - 3" 12' - 10" 46.9 12' - 3" 13' - 1" 46.6 13' - 10" 13' - 8" 47.0 14' - 1" 14' - 9" 47.6 14' - 2" 15' - 0" 47.2 14' - 6" 14' - 11" 47.7 14' - 9" 16' - 3" 48.2 14' - 10" 16' - 7" 58.0 11' - 2" 11' - 4" 58.5 11' - 3" 11' - 10" 59.0 11' - 2" 12' - 1" 58.7 13' - 2" 12' - 8" 59.1 13' - 4" 13' - 7" 59.7 13' - 5" 13' - 11" 59.3 13' - 9" 13' - 10" 59.8 13' - 11" 15' - 1" 60.3 14' - 1" 15' - 4" 64.0 10' - 9" 10' - 11" 64.5 10' - 9" 11' - 5" 65.0 10' - 9" 11' - 8" 64.7 12' - 10" 12' - 2" 65.2 13' - 0" 13' - 2" 65.7 13' - 2" 13' - 5" 65.4 13' - 5" 13' - 4" 65.8 13' - 8" 14' - 6" 66.4 13' - 9" 14' - 10" 76.1 10' - 0" 10' - 3" 76.6 10' - 1" 10' - 8" 77.1 10' - 1" 10' - 11" 76.8 12' - 4" 11' - 5" 77.3 12' - 6" 12' - 4" 77.8 12' - 8" 12' - 7" 77.5 12' - 11" 12' - 6" 77.9 13' - 1" 13' - 8" 78.4 13' - 3" 13' - 11" 85.2 9' - 7" 9' - 10" 85.7 9' - 7" 10' - 3" 86.2 9' - 7" 10' - 5" 85.8 12' - 0" 10' - 11" 86.3 12' - 1" 11' - 10" 86.8 12' - 2" 12' - 0" 86.5 12' - 7" 12' - 0" 87.0 12' - 9" 13' - 1" 87.5 12' - 11" 13' - 4" Triple 13' - 0" 13' - 1" 13' - 0" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 12' - 0" 12' - 1" 12' - 0" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 11' - 7" 11' - 8" 11' - 7" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 10' - 10" 10' - 11" 10' - 11" 13' - 3" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 10' - 5" 10' - 5" 10' - 5" 12' - 8" 12' - 9" 12' - 10" 13' - 4" 13' - 4" 13' - 4" Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span. 60 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 3WxHF-36 Cellular Composite Deck 2.3 Light Weight Concrete (110 pcf) Maximum Unshored Spans Volume cy/100sf 5 1.080 1 Hour Fire Rating 1.389 2 Hour Fire Rating 1.466 3 Hour Fire Rating 1.755 D PANEL 7 3/16 C PANELS 6 1/4 N PANELS 6 1.235 Triple 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 13' - 8" 13' - 9" 13' - 8" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 13' - 2" 13' - 3" 13' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 13' - 0" 13' - 1" 13' - 0" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 12' - 3" 12' - 4" 12' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" 14' - 3" B PANELS 5 1/2 ACUSTADEK® Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 110 pcf Light Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 35.7 13' - 6" 13' - 5" 36.2 13' - 7" 14' - 0" 36.7 13' - 6" 14' - 3" 36.4 14' - 9" 15' - 0" 36.8 15' - 0" 16' - 1" 37.4 15' - 1" 16' - 5" 37.0 15' - 6" 16' - 4" 37.5 15' - 8" 17' - 10" 38.0 15' - 10" 18' - 2" 40.3 12' - 11" 12' - 11" 40.8 13' - 0" 13' - 6" 41.3 12' - 11" 13' - 9" 40.9 14' - 4" 14' - 5" 41.4 14' - 7" 15' - 6" 41.9 14' - 8" 15' - 9" 41.6 15' - 0" 15' - 8" 42.1 15' - 3" 17' - 1" 42.6 15' - 5" 17' - 5" 44.9 12' - 5" 12' - 6" 45.4 12' - 6" 13' - 0" 45.9 12' - 5" 13' - 3" 45.5 14' - 0" 13' - 11" 46.0 14' - 2" 14' - 11" 46.5 14' - 4" 15' - 3" 46.2 14' - 8" 15' - 2" 46.7 14' - 10" 16' - 6" 47.2 15' - 0" 16' - 10" 47.2 12' - 2" 12' - 3" 47.6 12' - 3" 12' - 9" 48.2 12' - 2" 13' - 0" 47.8 13' - 10" 13' - 8" 48.3 14' - 0" 14' - 8" 48.8 14' - 2" 15' - 0" 48.5 14' - 6" 14' - 11" 49.0 14' - 8" 16' - 3" 49.5 14' - 10" 16' - 7" 55.8 11' - 5" 11' - 7" 56.2 11' - 6" 12' - 1" 56.8 11' - 5" 12' - 4" 56.4 13' - 4" 12' - 11" 56.9 13' - 6" 13' - 11" 57.4 13' - 8" 14' - 2" 57.1 13' - 11" 14' - 1" 57.6 14' - 2" 15' - 4" 58.1 14' - 4" 15' - 8" 2W PANELS Total Slab Depth (in) 3W PANELS 3WxHF-36 Cellular Shoring Table Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span. www.ascsd.com GENERAL INFORMATION Composite and Non-Composite Deck Catalog • February 2016 61 TABLE OF CONTENTS 2.4 3WxH-36 Composite Deck 5" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.080yd3/100ft2 Gage 22 21 20 GA 22 Single 10' - 1" 11' - 0" 11' - 9" Maximum Unshored Span (in) Triple Gage 11' - 4" 19 12' - 2" 18 12' - 11" 16 Double 11' - 0" 11' - 9" 12' - 6" Vertical Load Span (in) 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 282 451 - 246 394 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2367 2342 2319 2309 2291 2274 2178 2163 2151 2150 2139 2129 2163 2150 2138 2137 2127 2118 2149 2137 2125 2126 2116 2107 ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 20 70 112 - 63 101 - 57 90 - Attachment Pattern 2244 2231 2227 2112 2105 2106 2102 2095 2096 2092 2086 2088 2216 2099 2090 2082 2205 2093 2084 2076 2196 2087 2079 2071 2187 2082 2074 2066 2178 2077 2069 2062 Mno/Ω= 31.6 kip-in/ft ϕMno= 48.4 kip-in/ft 311 498 - ASD & LRFD - Superimposed Load, W (psf) 272 239 211 187 167 149 133 120 435 382 337 299 266 238 213 192 - 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 338 541 - 296 473 - 36/4 2306 2147 2135 2124 108 172 - 97 155 - 88 140 - 79 127 - 72 114 - 65 103 - Attachment Pattern 2289 2274 2271 2138 2129 2132 2126 2118 2121 2116 2108 2111 2258 2124 2113 2104 2246 2117 2107 2098 2234 2110 2100 2092 2224 2104 2094 2086 2214 2098 2089 2081 Mno/Ω= 34.6 kip-in/ft ϕMno= 52.9 kip-in/ft Icr = 42.3 in4/ft Iu = 108.6 in4/ft 9'-0" Vn/Ω = 3.30 kip/ft ϕ Vn = 4.76 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2430 2401 2375 2365 2343 2324 2213 2196 2181 2182 2169 2158 2196 2180 2166 2168 2156 2145 2181 2166 2153 2155 2144 2134 Vn/Ω = 3.82 kip/ft ϕ Vn = 5.66 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 260 230 204 182 163 147 132 416 368 327 292 261 234 211 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2477 2445 2416 2407 2383 2361 2239 2220 2204 2206 2192 2179 2220 2203 2188 2190 2177 2165 2205 2189 2174 2177 2165 2153 Concrete + Deck = 44.4 psf (Icr+Iu)/2 = 77.5 in4/ft 62 78 124 - 8'-6" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 2258 2120 2110 2100 86 138 - 8'-0" Concrete + Deck = 44.3 psf (Icr+Iu)/2 = 75.4 in4/ft Triple 14' - 4" 14' - 9" 15' - 7" 96 154 - Icr = 39.2 in4/ft Iu = 107.1 in4/ft 9'-0" Double 13' - 10" 15' - 2" 16' - 7" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 216 190 169 150 134 119 107 345 304 270 240 214 191 171 - Concrete + Deck = 44.0 psf (Icr+Iu)/2 = 73.2 in4/ft Vertical Load Span (in) Single 12' - 3" 12' - 7" 13' - 3" 36/4 2341 2168 2154 2143 119 190 - 107 172 - 97 155 - 88 141 - 80 128 - 72 116 - Attachment Pattern 2323 2307 2304 2157 2147 2151 2144 2135 2139 2134 2125 2130 2289 2142 2131 2122 2276 2134 2124 2115 2263 2127 2117 2108 2252 2120 2110 2102 2241 2114 2104 2096 Icr = 45.1 in4/ft Iu = 110.0 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 37.3 kip-in/ft ϕMno= 57.1 kip-in/ft Vn/Ω = 3.82 kip/ft ϕ Vn = 5.73 kip/ft www.ascsd.com TABLE OF CONTENTS 5" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.080yd3/100ft2 Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" 394 630 - ASD & LRFD - Superimposed Load, W (psf) 345 304 270 240 215 192 173 156 552 487 431 384 343 308 277 250 - 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2579 2540 2506 2497 2468 2442 2295 2273 2254 2258 2241 2226 2274 2253 2235 2241 2225 2210 2258 2238 2220 2227 2212 2198 18 97 154 - 88 141 - Attachment Pattern 2397 2377 2376 2200 2188 2194 2185 2174 2181 2174 2163 2170 2358 2184 2171 2161 2342 2174 2161 2152 2327 2165 2153 2144 2313 2156 2145 2136 2300 2149 2137 2129 Mno/Ω= 42.9 kip-in/ft ϕMno= 65.7 kip-in/ft 443 709 - ASD & LRFD - Superimposed Load, W (psf) 389 343 304 271 243 218 197 178 622 549 487 434 389 349 315 285 - 9'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 546 874 - 480 768 - 147 235 - 134 214 - 122 195 - 111 178 - 102 163 - Attachment Pattern 2470 2447 2448 2243 2229 2238 2226 2213 2223 2215 2202 2212 2427 2226 2211 2201 2408 2214 2200 2190 2391 2204 2190 2181 2374 2194 2181 2171 2359 2184 2172 2163 Mno/Ω= 47.9 kip-in/ft ϕMno= 73.2 kip-in/ft 9'-0" Vn/Ω = 3.82 kip/ft ϕ Vn = 5.73 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 424 377 337 303 273 247 224 679 604 540 484 436 395 358 36/4 2666 2359 2326 2326 186 297 - 170 271 - 155 248 - 142 228 142 129 209 129 Attachment Pattern 2633 2602 2609 2339 2321 2339 2308 2291 2310 2308 2291 2310 2581 2322 2294 2294 2556 2307 2279 2280 2533 2292 2266 2266 2511 2279 2253 2254 2491 2266 2242 2242 Mno/Ω= 58.3 kip-in/ft ϕMno= 89.2 kip-in/ft Icr = 64.9 in4/ft Iu = 120.7 in4/ft Vn/Ω = 3.82 kip/ft ϕ Vn = 5.73 kip/ft D PANEL LRFD - Diaphragm Shear, ϕSn (plf / ft) 2898 2840 2788 2786 2742 2702 2477 2443 2413 2431 2405 2381 2431 2400 2372 2393 2368 2346 2431 2400 2373 2393 2369 2346 204 326 - C PANELS 8'-0" 36/4 2496 2258 2240 2228 162 258 - N PANELS Vertical Load Span (in) Vn/Ω = 3.82 kip/ft ϕ Vn = 5.73 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" Icr = 55.4 in4/ft Iu = 115.4 in4/ft Concrete + Deck = 45.7 psf (Icr+Iu)/2 = 92.8 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft 3200 3200 3200 6x6 W2.9xW2.9 As = 0.058 in2/ft 4550 4550 4550 6x6 W4.0xW4.0 As = 0.080 in2/ft 5540 5540 5170 4x4 W4xW4 As = 0.120 in2/ft 7340 7340 5170 4x4 W6xW6 As = 0.180 in2/ft 10040 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 106 170 - 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 2679 2634 2594 2587 2554 2523 PAF Base Steel ≥ .25" 2352 2326 2303 2312 2292 2274 PAF Base Steel ≥ 0.125" 2328 2304 2282 2292 2273 2256 #12 Screw Base Steel ≥ .0385" 2311 2288 2267 2278 2259 2243 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 116 186 - 8'-0" Concrete + Deck = 45.0 psf (Icr+Iu)/2 = 85.4 in4/ft 16 128 205 - B PANELS ASD, W/Ω LRFD, ϕW L/360 36/4 2418 2212 2197 2185 141 226 - Icr = 50.6 in4/ft Iu = 112.8 in4/ft Concrete + Deck = 44.8 psf (Icr+Iu)/2 = 81.7 in4/ft Vertical Load Span (in) 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 2W PANELS 19 8'-0" 3W PANELS GA 3WxH-36 Composite Deck 2.4 GENERAL INFORMATION 63 TABLE OF CONTENTS 2.4 3WxH-36 Composite Deck 6" Total Slab Depth Normal Weight Concrete (145 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.389yd3/100ft2 Single 9' - 3" 10' - 1" 10' - 10" Maximum Unshored Span (in) Triple Gage 10' - 5" 19 11' - 2" 18 11' - 10" 16 Double 10' - 1" 10' - 10" 11' - 6" Vertical Load Span (in) 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 380 607 - 331 530 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3348 3323 3300 3290 3271 3254 3159 3144 3132 3131 3120 3110 3144 3130 3118 3118 3108 3099 3130 3117 3106 3107 3097 3088 ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 20 96 153 - 86 138 - 78 125 - Attachment Pattern 3225 3212 3208 3093 3086 3087 3083 3076 3077 3073 3067 3069 3197 3080 3071 3063 3186 3074 3065 3057 3177 3068 3060 3052 3168 3063 3055 3047 3159 3058 3050 3043 Mno/Ω= 42.3 kip-in/ft ϕMno= 64.8 kip-in/ft 419 670 - ASD & LRFD - Superimposed Load, W (psf) 366 322 285 253 225 202 181 163 586 515 455 404 360 322 289 260 - 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 455 729 - 399 638 - 36/4 3286 3128 3116 3105 147 234 - 132 212 - 120 191 - 108 173 - 98 157 - 89 142 - Attachment Pattern 3270 3255 3252 3119 3110 3112 3107 3099 3102 3097 3089 3092 3239 3105 3094 3085 3226 3097 3088 3079 3215 3091 3081 3073 3205 3085 3075 3067 3195 3079 3070 3062 Mno/Ω= 46.3 kip-in/ft ϕMno= 70.8 kip-in/ft Icr = 68.6 in4/ft Iu = 184.7 in4/ft 9'-0" Vn/Ω = 3.85 kip/ft ϕ Vn = 5.57 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3411 3382 3356 3346 3324 3304 3193 3177 3162 3162 3150 3138 3177 3161 3147 3148 3136 3126 3162 3147 3134 3136 3125 3114 Vn/Ω = 4.50 kip/ft ϕ Vn = 6.47 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 351 311 276 247 221 199 179 561 497 442 395 353 318 286 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 3458 3426 3397 3387 3363 3342 3219 3201 3185 3186 3172 3160 3201 3184 3169 3171 3158 3146 3186 3170 3155 3158 3146 3134 Concrete + Deck = 56.5 psf (Icr+Iu)/2 = 130 in4/ft 64 106 170 - 8'-6" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 3239 3101 3090 3080 118 188 - 8'-0" Concrete + Deck = 56.4 psf (Icr+Iu)/2 = 127 in4/ft Triple 13' - 3" 14' - 0" 14' - 9" 131 209 - Icr = 63.6 in4/ft Iu = 182.5 in4/ft 9'-0" Double 12' - 9" 13' - 11" 15' - 7" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 291 257 228 203 181 162 145 466 411 364 324 289 259 232 - Concrete + Deck = 56.1 psf (Icr+Iu)/2 = 123 in4/ft Vertical Load Span (in) Single 11' - 7" 11' - 11" 12' - 7" 36/4 3322 3148 3135 3124 162 258 - 146 234 - 132 212 - 120 192 - 109 175 - 99 159 - Attachment Pattern 3304 3287 3285 3138 3128 3132 3125 3116 3120 3115 3106 3110 3270 3123 3112 3103 3257 3115 3104 3095 3244 3108 3097 3089 3233 3101 3091 3082 3222 3094 3085 3077 Icr = 73.2 in4/ft Iu = 186.9 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 50.0 kip-in/ft ϕMno= 76.5 kip-in/ft Vn/Ω = 4.90 kip/ft ϕ Vn = 7.27 kip/ft www.ascsd.com TABLE OF CONTENTS 3WxH-36 Composite Deck 2.4 6" Total Slab Depth Normal Weight Concrete (145 pcf) Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" 531 849 - ASD & LRFD - Superimposed Load, W (psf) 465 410 364 324 290 261 235 212 744 656 582 519 464 417 376 339 - 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3560 3521 3486 3478 3449 3423 3276 3254 3234 3239 3222 3207 3255 3234 3216 3221 3205 3191 3239 3219 3201 3208 3193 3179 18 Attachment Pattern 3378 3358 3357 3180 3169 3175 3166 3155 3162 3155 3144 3151 3339 3165 3152 3142 3323 3155 3142 3133 3308 3146 3134 3124 3294 3137 3126 3117 3281 3129 3118 3110 Mno/Ω= 57.6 kip-in/ft ϕMno= 88.1 kip-in/ft 598 956 - ASD & LRFD - Superimposed Load, W (psf) 524 463 411 367 329 296 267 242 839 741 658 587 526 473 427 387 - 9'-0" 8'-0" 8'-6" 737 648 1179 1037 - 9'-0" Vn/Ω = 4.90 kip/ft ϕ Vn = 7.35 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 36/4 3476 3238 3221 3209 219 351 - 200 320 - 182 291 - 166 266 - 152 243 - 139 223 - Attachment Pattern 3451 3428 3429 3223 3210 3219 3207 3194 3204 3195 3183 3193 3408 3207 3192 3182 3389 3195 3181 3171 3372 3185 3171 3161 3355 3175 3161 3152 3340 3165 3153 3144 Mno/Ω= 64.3 kip-in/ft ϕMno= 98.4 kip-in/ft Icr = 90.2 in4/ft Iu = 195.2 in4/ft Vn/Ω = 4.90 kip/ft ϕ Vn = 7.35 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 573 510 456 410 369 334 304 917 816 730 656 591 535 486 36/4 3647 3340 3307 3307 276 442 - 252 404 - 231 369 - 212 338 - 194 311 - 179 286 - Attachment Pattern 3613 3583 3589 3320 3302 3320 3288 3272 3290 3289 3272 3291 3562 3303 3275 3275 3537 3287 3260 3261 3514 3273 3247 3247 3492 3260 3234 3235 3472 3247 3223 3223 Mno/Ω= 78.4 kip-in/ft ϕMno= 119.9 kip-in/ft Icr = 105.8 in4/ft Iu = 203.3 in4/ft Vn/Ω = 4.90 kip/ft ϕ Vn = 7.35 kip/ft D PANEL LRFD - Diaphragm Shear, ϕSn (plf / ft) 3879 3820 3768 3767 3723 3683 3458 3424 3394 3412 3386 3362 3412 3381 3353 3374 3349 3327 3412 3381 3354 3374 3350 3327 Concrete + Deck = 57.8 psf (Icr+Iu)/2 = 155 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft 4190 4190 4190 6x6 W2.9xW2.9 As = 0.058 in2/ft 5540 5540 5170 6x6 W4.0xW4.0 As = 0.080 in2/ft 6530 6530 5170 4x4 W4xW4 As = 0.120 in2/ft 8330 7750 5170 4x4 W6xW6 As = 0.180 in2/ft 11030 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 120 193 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 132 211 - N PANELS 16 144 231 - 8'-6" Concrete + Deck = 57.1 psf (Icr+Iu)/2 = 143 in4/ft ASD, W/Ω LRFD, ϕW L/360 159 254 - 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 3660 3615 3575 3568 3534 3504 PAF Base Steel ≥ .25" 3333 3307 3284 3292 3273 3255 PAF Base Steel ≥ 0.125" 3309 3284 3263 3272 3254 3237 #12 Screw Base Steel ≥ .0385" 3292 3269 3248 3258 3240 3224 Vertical Load Span (in) 174 279 - B PANELS ASD, W/Ω LRFD, ϕW L/360 36/4 3399 3193 3178 3166 192 307 - Icr = 82.3 in4/ft Iu = 191.2 in4/ft Concrete + Deck = 56.9 psf (Icr+Iu)/2 = 137 in4/ft Vertical Load Span (in) 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 2W PANELS 19 8'-0" 3W PANELS GA Concrete Volume 1.389yd3/100ft2 GENERAL INFORMATION 65 TABLE OF CONTENTS 2.4 3WxH-36 Composite Deck 6 1⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.543yd3/100ft2 1 Hour Fire Rating Single 8' - 11" 9' - 8" 10' - 5" Maximum Unshored Span (in) Triple Gage 10' - 1" 19 10' - 9" 18 11' - 5" 16 Double 9' - 9" 10' - 5" 11' - 1" Vertical Load Span (in) 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 432 691 - 377 603 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3839 3813 3790 3781 3762 3745 3649 3635 3622 3621 3610 3600 3634 3621 3609 3609 3598 3589 3621 3608 3597 3597 3587 3579 ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 20 110 175 - 99 158 - 89 143 - Attachment Pattern 3715 3702 3698 3583 3576 3577 3573 3566 3568 3564 3557 3559 3687 3571 3561 3553 3677 3564 3556 3548 3667 3559 3550 3542 3658 3553 3545 3538 3649 3548 3541 3533 Mno/Ω= 48.0 kip-in/ft ϕMno= 73.5 kip-in/ft 476 762 - ASD & LRFD - Superimposed Load, W (psf) 417 366 324 288 257 230 206 186 666 586 519 461 411 368 330 297 - 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 518 829 - 454 726 - 36/4 3777 3619 3606 3596 167 268 - 151 242 - 137 219 - 124 198 - 112 180 - 102 163 - Attachment Pattern 3761 3746 3742 3609 3600 3603 3597 3589 3592 3587 3579 3583 3729 3595 3585 3576 3717 3588 3578 3569 3706 3581 3572 3563 3695 3575 3566 3558 3685 3569 3560 3552 Mno/Ω= 52.5 kip-in/ft ϕMno= 80.3 kip-in/ft Icr = 84.9 in4/ft Iu = 233.8 in4/ft 9'-0" Vn/Ω = 4.14 kip/ft ϕ Vn = 6.01 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3902 3872 3846 3836 3815 3795 3684 3667 3652 3653 3640 3629 3667 3651 3638 3639 3627 3616 3652 3638 3624 3626 3615 3605 Vn/Ω = 4.80 kip/ft ϕ Vn = 6.91 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 400 354 315 281 252 227 204 639 566 504 450 403 362 327 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 3949 3916 3887 3878 3854 3832 3710 3691 3675 3677 3663 3650 3692 3674 3659 3662 3648 3636 3676 3660 3645 3649 3636 3625 Concrete + Deck = 62.5 psf (Icr+Iu)/2 = 163 in4/ft 66 121 194 - 8'-6" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 3729 3592 3581 3571 134 215 - 8'-0" Concrete + Deck = 62.4 psf (Icr+Iu)/2 = 159 in4/ft Triple 12' - 9" 13' - 8" 14' - 5" 149 239 - Icr = 78.7 in4/ft Iu = 231.1 in4/ft 9'-0" Double 12' - 4" 13' - 5" 15' - 0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 331 293 259 231 206 185 166 530 468 415 370 330 296 265 - Concrete + Deck = 62.2 psf (Icr+Iu)/2 = 155 in4/ft Vertical Load Span (in) Single 11' - 3" 11' - 8" 12' - 3" 36/4 3812 3639 3626 3614 185 295 - 167 267 - 152 242 - 138 220 - 125 200 - 114 182 - Attachment Pattern 3794 3778 3775 3628 3619 3622 3616 3607 3611 3605 3596 3601 3760 3614 3602 3593 3747 3606 3595 3586 3735 3598 3588 3579 3723 3591 3581 3573 3712 3585 3575 3567 Icr = 90.6 in4/ft Iu = 236.4 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 56.7 kip-in/ft ϕMno= 86.8 kip-in/ft Vn/Ω = 5.38 kip/ft ϕ Vn = 7.71 kip/ft www.ascsd.com TABLE OF CONTENTS 3WxH-36 Composite Deck 2.4 6 1⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.543yd3/100ft2 2 Hour Fire Rating Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" 604 966 - ASD & LRFD - Superimposed Load, W (psf) 530 467 415 369 331 297 268 242 847 748 663 591 529 475 429 387 - 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 4050 4011 3977 3968 3940 3913 3767 3744 3725 3730 3713 3697 3745 3725 3706 3712 3696 3681 3729 3709 3692 3698 3683 3669 18 Attachment Pattern 3868 3848 3847 3671 3659 3666 3656 3645 3652 3645 3634 3642 3829 3655 3642 3632 3813 3645 3633 3623 3798 3636 3624 3615 3784 3628 3616 3607 3771 3620 3609 3600 Mno/Ω= 65.4 kip-in/ft ϕMno= 100.0 kip-in/ft 681 1089 - ASD & LRFD - Superimposed Load, W (psf) 598 528 469 419 375 338 305 276 956 845 750 670 600 540 488 442 - 9'-0" 8'-0" 8'-6" 9'-0" Vn/Ω = 5.49 kip/ft ϕ Vn = 8.23 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 36/4 3967 3729 3711 3699 251 401 - 228 365 - 208 333 - 190 305 - 174 279 - 160 256 - Attachment Pattern 3942 3918 3919 3714 3700 3710 3697 3684 3694 3686 3673 3684 3899 3697 3682 3672 3880 3686 3672 3662 3862 3675 3661 3652 3846 3665 3652 3643 3830 3656 3643 3634 Mno/Ω= 73.1 kip-in/ft ϕMno= 111.8 kip-in/ft Icr = 111.7 in4/ft Iu = 246.6 in4/ft Vn/Ω = 5.49 kip/ft ϕ Vn = 8.23 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 840 739 654 582 521 468 422 382 347 1345 1182 1046 931 833 748 675 611 555 36/4 4137 3831 3797 3798 316 505 - 288 462 - 264 422 - 242 387 - 222 356 - 205 328 - Attachment Pattern 4104 4073 4080 3811 3793 3810 3779 3762 3781 3779 3762 3781 4053 3793 3765 3766 4028 3778 3751 3751 4004 3763 3737 3738 3983 3750 3725 3725 3962 3738 3713 3713 Mno/Ω= 89.2 kip-in/ft ϕMno= 136.4 kip-in/ft Icr = 131.2 in4/ft Iu = 256.4 in4/ft Vn/Ω = 5.49 kip/ft ϕ Vn = 8.23 kip/ft D PANEL LRFD - Diaphragm Shear, ϕSn (plf / ft) 4369 4311 4259 4257 4213 4173 3948 3914 3884 3903 3876 3852 3902 3871 3844 3864 3840 3817 3903 3872 3844 3864 3840 3818 Concrete + Deck = 63.9 psf (Icr+Iu)/2 = 194 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft n/a n/a n/a 6x6 W2.9xW2.9 As = 0.058 in2/ft 6030 6030 5170 6x6 W4.0xW4.0 As = 0.080 in2/ft 7020 7020 5170 4x4 W4xW4 As = 0.120 in2/ft 8820 7750 5170 4x4 W6xW6 As = 0.180 in2/ft 11520 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 138 221 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 151 242 - N PANELS 16 165 265 - 8'-6" Concrete + Deck = 63.2 psf (Icr+Iu)/2 = 179 in4/ft ASD, W/Ω LRFD, ϕW L/360 181 290 - 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 4150 4105 4065 4059 4025 3994 PAF Base Steel ≥ .25" 3823 3797 3774 3783 3763 3745 PAF Base Steel ≥ 0.125" 3799 3775 3753 3763 3744 3727 #12 Screw Base Steel ≥ .0385" 3783 3759 3739 3749 3731 3714 Vertical Load Span (in) 199 319 - B PANELS ASD, W/Ω LRFD, ϕW L/360 36/4 3890 3684 3668 3656 219 351 - Icr = 101.9 in4/ft Iu = 241.7 in4/ft Concrete + Deck = 63.0 psf (Icr+Iu)/2 = 172 in4/ft Vertical Load Span (in) 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 2W PANELS 19 8'-0" 3W PANELS GA GENERAL INFORMATION 67 TABLE OF CONTENTS 2.4 3WxH-36 Composite Deck 7 1⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.852yd3/100ft2 2 Hour Fire Rating Single 8' - 4" 9' - 0" 9' - 8" Maximum Unshored Span (in) Triple Gage 9' - 5" 19 10' - 1" 18 10' - 8" 16 Double 9' - 1" 9' - 9" 10' - 4" Vertical Load Span (in) 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 540 864 - 472 756 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 4819 4794 4771 4762 4743 4726 4630 4616 4603 4602 4591 4581 4615 4602 4590 4590 4579 4570 4601 4589 4577 4578 4568 4560 ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 20 139 222 - 126 201 - 114 182 - Attachment Pattern 4696 4683 4679 4564 4557 4558 4554 4547 4549 4544 4538 4540 4668 4551 4542 4534 4658 4545 4537 4528 4648 4540 4531 4523 4639 4534 4526 4519 4630 4529 4521 4514 Mno/Ω= 59.8 kip-in/ft ϕMno= 91.5 kip-in/ft 596 954 - ASD & LRFD - Superimposed Load, W (psf) 522 459 407 362 323 289 260 234 835 735 651 579 516 463 416 374 - 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 649 1038 - 568 910 - 36/4 4758 4599 4587 4576 211 338 - 191 306 - 173 277 - 157 251 - 143 228 - 130 207 - Attachment Pattern 4741 4726 4723 4590 4581 4584 4578 4570 4573 4568 4560 4564 4710 4576 4566 4557 4698 4569 4559 4550 4686 4562 4552 4544 4676 4556 4547 4538 4666 4550 4541 4533 Mno/Ω= 65.5 kip-in/ft ϕMno= 100.2 kip-in/ft Icr = 123.6 in4/ft Iu = 358.0 in4/ft 9'-0" Vn/Ω = 4.76 kip/ft ϕ Vn = 6.94 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 4883 4853 4827 4817 4795 4776 4665 4648 4633 4634 4621 4610 4648 4632 4618 4620 4608 4597 4633 4618 4605 4607 4596 4586 Vn/Ω = 5.42 kip/ft ϕ Vn = 7.84 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 501 444 395 353 317 285 257 802 710 632 565 507 456 412 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 4929 4897 4868 4859 4835 4813 4691 4672 4656 4658 4644 4631 4673 4655 4640 4642 4629 4617 4657 4641 4626 4630 4617 4606 Concrete + Deck = 74.6 psf (Icr+Iu)/2 = 247 in4/ft 68 154 246 - 8'-6" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 4710 4572 4562 4552 170 272 - 8'-0" Concrete + Deck = 74.5 psf (Icr+Iu)/2 = 241 in4/ft Triple 11' - 11" 13' - 0" 13' - 10" 188 301 - Icr = 114.4 in4/ft Iu = 354.1 in4/ft 9'-0" Double 11' - 6" 12' - 7" 14' - 1" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 415 367 326 290 260 233 209 664 587 521 464 415 372 335 - Concrete + Deck = 74.2 psf (Icr+Iu)/2 = 234 in4/ft Vertical Load Span (in) Single 10' - 8" 11' - 2" 11' - 9" 36/4 4793 4620 4606 4595 233 372 - 211 338 - 192 307 - 174 279 - 159 254 - 145 231 - Attachment Pattern 4775 4759 4756 4609 4600 4603 4597 4587 4592 4586 4577 4582 4741 4594 4583 4574 4728 4586 4576 4567 4715 4579 4569 4560 4704 4572 4562 4554 4693 4566 4556 4548 Icr = 132.0 in4/ft Iu = 361.6 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 70.8 kip-in/ft ϕMno= 108.3 kip-in/ft Vn/Ω = 6.01 kip/ft ϕ Vn = 8.64 kip/ft www.ascsd.com TABLE OF CONTENTS 7 1⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.852yd3/100ft2 2 Hour Fire Rating Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 5031 4992 4958 4949 4920 4894 4747 4725 4706 4711 4694 4678 4726 4706 4687 4693 4677 4662 4710 4690 4673 4679 4664 4650 18 8'-6" 9'-0" 8'-0" 8'-6" 9'-0" Attachment Pattern 4849 4829 4828 4652 4640 4646 4637 4626 4633 4626 4615 4623 4810 4636 4623 4613 4794 4626 4614 4604 4779 4617 4605 4596 4765 4609 4597 4588 4752 4601 4590 4581 Mno/Ω= 81.7 kip-in/ft ϕMno= 125.0 kip-in/ft Vn/Ω = 6.73 kip/ft ϕ Vn = 10.09 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 36/4 4948 4710 4692 4680 317 507 - 289 462 - 264 422 - 241 386 - 221 354 - 203 324 - Attachment Pattern 4922 4899 4900 4695 4681 4690 4678 4665 4675 4667 4654 4665 4879 4678 4663 4653 4860 4667 4652 4643 4843 4656 4642 4633 4826 4646 4633 4624 4811 4637 4624 4615 Mno/Ω= 91.5 kip-in/ft ϕMno= 140.0 kip-in/ft Vn/Ω = 6.73 kip/ft ϕ Vn = 10.09 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 1057 930 823 733 656 590 532 482 438 1691 1488 1317 1173 1050 944 852 771 701 36/4 5118 4811 4778 4778 399 639 - 365 584 - 334 535 - 307 491 - 282 451 - 260 416 - Attachment Pattern 5085 5054 5061 4792 4773 4791 4760 4743 4762 4760 4743 4762 5034 4774 4746 4746 5008 4759 4732 4732 4985 4744 4718 4718 4963 4731 4706 4706 4943 4718 4694 4694 Mno/Ω= 111.8 kip-in/ft ϕMno= 171.1 kip-in/ft Icr = 192.5 in4/ft Iu = 390.2 in4/ft Vn/Ω = 6.73 kip/ft ϕ Vn = 10.09 kip/ft D PANEL LRFD - Diaphragm Shear, ϕSn (plf / ft) 5350 5292 5240 5238 5194 5154 4929 4895 4865 4883 4857 4833 4883 4852 4824 4845 4820 4798 4884 4852 4825 4845 4821 4799 Concrete + Deck = 75.9 psf (Icr+Iu)/2 = 291 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft n/a n/a n/a 6x6 W2.9xW2.9 As = 0.058 in2/ft 7020 7020 5170 6x6 W4.0xW4.0 As = 0.080 in2/ft 8010 7750 5170 4x4 W4xW4 As = 0.120 in2/ft 9810 7750 5170 4x4 W6xW6 As = 0.180 in2/ft 12510 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 175 280 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 191 306 - N PANELS 16 209 335 - Icr = 163.5 in4/ft Iu = 376.2 in4/ft Concrete + Deck = 75.3 psf (Icr+Iu)/2 = 270 in4/ft ASD, W/Ω LRFD, ϕW L/360 229 367 - ASD & LRFD - Superimposed Load, W (psf) 855 751 664 590 527 473 426 385 349 1368 1201 1062 944 843 756 681 615 558 - LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 5131 5086 5046 5039 5006 4975 PAF Base Steel ≥ .25" 4804 4778 4755 4764 4744 4726 PAF Base Steel ≥ 0.125" 4780 4756 4734 4744 4725 4708 #12 Screw Base Steel ≥ .0385" 4764 4740 4719 4730 4712 4695 Vertical Load Span (in) 252 403 - B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" 36/4 4871 4664 4649 4637 277 443 - Icr = 148.9 in4/ft Iu = 369.2 in4/ft Concrete + Deck = 75.1 psf (Icr+Iu)/2 = 259 in4/ft Vertical Load Span (in) 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 757 664 586 521 464 416 374 337 305 1212 1063 938 833 743 666 598 540 488 - 2W PANELS 19 8'-0" 3W PANELS GA 3WxH-36 Composite Deck 2.4 GENERAL INFORMATION 69 TABLE OF CONTENTS 2.4 3WxH-36 Composite Deck 8 1⁄4" Total Slab Depth Normal Weight Concrete (145 pcf) Gage 22 21 20 GA 22 Concrete Volume 2.083yd3/100ft2 3 Hour Fire Rating Single 7' - 11" 8' - 7" 9' - 3" Maximum Unshored Span (in) Triple Gage 9' - 0" 19 9' - 8" 18 10' - 3" 16 Double 8' - 9" 9' - 4" 9' - 11" Vertical Load Span (in) 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 625 999 - 546 874 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 5555 5530 5507 5497 5478 5461 5366 5351 5338 5338 5327 5317 5351 5337 5325 5325 5315 5306 5337 5324 5313 5314 5304 5295 ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 20 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 179 286 - 162 259 - 147 235 - 133 213 - Attachment Pattern 5432 5419 5415 5300 5293 5294 5290 5283 5284 5280 5274 5275 5404 5287 5278 5270 5393 5281 5272 5264 5383 5275 5267 5259 5374 5270 5262 5254 5366 5265 5257 5250 Mno/Ω= 69.0 kip-in/ft ϕMno= 105.5 kip-in/ft 8'-6" 690 1104 - ASD & LRFD - Superimposed Load, W (psf) 604 532 471 419 374 335 301 272 966 851 753 670 599 536 482 435 - 8'-0" 8'-6" 751 658 1201 1052 - 36/4 5493 5335 5323 5312 245 393 - 222 356 - 202 322 - 183 293 - 166 266 - 151 242 - Attachment Pattern 5477 5462 5459 5326 5317 5319 5314 5306 5309 5304 5296 5299 5446 5312 5301 5292 5433 5304 5294 5286 5422 5298 5288 5280 5412 5291 5282 5274 5402 5286 5277 5269 Mno/Ω= 75.5 kip-in/ft ϕMno= 115.6 kip-in/ft Icr = 158.2 in4/ft Iu = 476.7 in4/ft 9'-0" Vn/Ω = 5.37 kip/ft ϕ Vn = 7.86 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 5618 5589 5563 5553 5531 5511 5400 5384 5369 5369 5357 5345 5384 5368 5354 5355 5343 5333 5369 5354 5341 5343 5332 5321 Vn/Ω = 6.03 kip/ft ϕ Vn = 8.76 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 580 514 458 409 367 331 299 928 823 733 655 588 529 478 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 5665 5633 5604 5594 5570 5549 5426 5408 5392 5393 5379 5367 5408 5391 5376 5378 5365 5353 5393 5376 5362 5365 5353 5341 Concrete + Deck = 83.7 psf (Icr+Iu)/2 = 325 in4/ft 70 36/4 5446 5308 5297 5287 198 316 - 8'-0" Concrete + Deck = 83.6 psf (Icr+Iu)/2 = 317 in4/ft Triple 11' - 5" 12' - 5" 13' - 5" 219 350 - Icr = 146.3 in4/ft Iu = 471.8 in4/ft 9'-0" Double 11' - 0" 12' - 1" 13' - 6" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 480 425 377 336 301 270 243 769 680 604 538 481 432 389 - Concrete + Deck = 83.3 psf (Icr+Iu)/2 = 309 in4/ft Vertical Load Span (in) Single 10' - 3" 10' - 9" 11' - 5" 36/4 5529 5355 5342 5331 270 433 - 245 392 - 223 357 - 203 325 - 185 296 - 169 270 - Attachment Pattern 5511 5494 5492 5345 5335 5339 5332 5323 5327 5322 5313 5317 5477 5330 5319 5310 5464 5322 5311 5302 5451 5315 5304 5296 5439 5308 5298 5289 5429 5301 5292 5284 Icr = 169.0 in4/ft Iu = 481.3 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 81.7 kip-in/ft ϕMno= 124.9 kip-in/ft Vn/Ω = 6.62 kip/ft ϕ Vn = 9.56 kip/ft www.ascsd.com TABLE OF CONTENTS 8 1⁄4" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 2.083yd3/100ft2 3 Hour Fire Rating Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 5767 5728 5693 5685 5656 5630 5483 5461 5441 5446 5429 5414 5462 5441 5423 5428 5412 5398 5446 5426 5408 5415 5399 5386 18 8'-6" 9'-0" 8'-0" 8'-6" 9'-0" Attachment Pattern 5585 5565 5563 5387 5376 5382 5373 5362 5369 5361 5351 5358 5546 5371 5359 5349 5530 5362 5349 5340 5515 5353 5341 5331 5501 5344 5333 5324 5488 5336 5325 5317 Mno/Ω= 94.3 kip-in/ft ϕMno= 144.3 kip-in/ft Vn/Ω = 7.69 kip/ft ϕ Vn = 11.01 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 36/4 5683 5445 5428 5416 368 589 - 336 537 - 307 491 - 281 449 - 258 412 - 237 378 - Attachment Pattern 5658 5635 5636 5430 5417 5426 5414 5401 5411 5402 5390 5400 5615 5414 5399 5389 5596 5402 5388 5378 5578 5391 5378 5368 5562 5382 5368 5359 5547 5372 5359 5351 Mno/Ω= 105.8 kip-in/ft ϕMno= 161.9 kip-in/ft Vn/Ω = 7.95 kip/ft ϕ Vn = 11.93 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 1226 1079 956 851 762 685 619 561 510 1962 1726 1529 1362 1219 1096 990 897 815 36/4 5854 5547 5514 5514 465 743 - 425 680 - 389 623 - 358 572 - 329 526 - 303 485 - Attachment Pattern 5820 5790 5796 5527 5509 5527 5495 5479 5497 5496 5479 5498 5769 5510 5482 5482 5744 5494 5467 5468 5721 5480 5454 5454 5699 5467 5441 5442 5679 5454 5430 5430 Mno/Ω= 129.5 kip-in/ft ϕMno= 198.2 kip-in/ft Icr = 247.7 in4/ft Iu = 517.6 in4/ft Vn/Ω = 7.95 kip/ft ϕ Vn = 11.93 kip/ft D PANEL LRFD - Diaphragm Shear, ϕSn (plf / ft) 6086 6027 5975 5974 5930 5890 5664 5631 5601 5619 5593 5569 5619 5588 5560 5581 5556 5534 5619 5588 5561 5581 5556 5534 Concrete + Deck = 85.0 psf (Icr+Iu)/2 = 383 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft n/a n/a n/a 6x6 W2.9xW2.9 As = 0.058 in2/ft 7760 7750 5170 6x6 W4.0xW4.0 As = 0.080 in2/ft 8750 7750 5170 4x4 W4xW4 As = 0.120 in2/ft 10550 7750 5170 4x4 W6xW6 As = 0.180 in2/ft 13250 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 204 327 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 223 357 - N PANELS 16 244 390 - Icr = 210.0 in4/ft Iu = 499.7 in4/ft Concrete + Deck = 84.3 psf (Icr+Iu)/2 = 355 in4/ft ASD, W/Ω LRFD, ϕW L/360 267 427 - ASD & LRFD - Superimposed Load, W (psf) 991 870 769 684 611 549 494 447 405 1585 1392 1231 1095 978 878 791 715 648 - LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 5867 5822 5782 5775 5741 5711 PAF Base Steel ≥ .25" 5540 5514 5491 5499 5480 5462 PAF Base Steel ≥ 0.125" 5516 5491 5470 5479 5460 5443 #12 Screw Base Steel ≥ .0385" 5499 5476 5455 5465 5447 5431 Vertical Load Span (in) 293 468 - B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" 36/4 5606 5400 5385 5373 322 515 - Icr = 190.9 in4/ft Iu = 490.8 in4/ft Concrete + Deck = 84.1 psf (Icr+Iu)/2 = 341 in4/ft Vertical Load Span (in) 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 876 769 679 603 538 482 434 392 355 1402 1231 1087 965 861 772 694 627 567 - 2W PANELS 19 8'-0" 3W PANELS GA 3WxH-36 Composite Deck 2.4 GENERAL INFORMATION 71 TABLE OF CONTENTS 2.4 3WxH-36 Composite Deck 5" Total Slab Depth Light Weight Concrete (110 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.080yd3/100ft2 Single 11' - 2" 12' - 2" 12' - 7" Maximum Unshored Span (in) Triple Gage 12' - 5" 19 13' - 4" 18 14' - 1" 16 Double 12' - 0" 12' - 10" 13' - 8" Vertical Load Span (in) 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 276 442 - 242 387 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 1711 1686 1663 1654 1635 1618 1522 1508 1495 1494 1483 1473 1507 1494 1482 1482 1471 1462 1493 1481 1469 1470 1460 1452 ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 20 73 117 - 66 106 - 60 97 - Attachment Pattern 1588 1575 1571 1456 1449 1450 1446 1439 1441 1436 1430 1432 1560 1443 1434 1426 1550 1437 1429 1420 1540 1432 1423 1415 1531 1426 1418 1411 1522 1421 1413 1406 Mno/Ω= 30.3 kip-in/ft ϕMno= 46.4 kip-in/ft 304 486 - ASD & LRFD - Superimposed Load, W (psf) 266 235 208 185 166 149 134 121 426 375 333 296 265 238 214 193 - 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 329 527 - 289 462 - 36/4 1651 1493 1481 1470 109 175 - 99 159 - 90 144 - 82 131 - 75 119 - 68 109 - Attachment Pattern 1635 1620 1616 1483 1475 1477 1472 1463 1466 1461 1454 1457 1603 1469 1459 1450 1591 1462 1452 1443 1580 1455 1446 1437 1569 1449 1440 1432 1559 1443 1434 1427 Mno/Ω= 33.1 kip-in/ft ϕMno= 50.6 kip-in/ft Icr = 57.4 in4/ft Iu = 116.5 in4/ft 9'-0" Vn/Ω = 2.83 kip/ft ϕ Vn = 4.05 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 1776 1746 1720 1710 1689 1669 1558 1541 1527 1527 1514 1503 1541 1526 1512 1513 1501 1490 1527 1512 1499 1501 1489 1479 Vn/Ω = 2.86 kip/ft ϕ Vn = 4.94 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 255 226 202 180 162 146 132 408 362 322 289 259 234 211 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 1824 1791 1762 1753 1729 1707 1585 1567 1550 1552 1538 1525 1567 1550 1534 1537 1524 1512 1552 1535 1521 1524 1511 1500 Concrete + Deck = 34.2 psf (Icr+Iu)/2 = 89.8 in4/ft 72 81 129 - 8'-6" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 1602 1464 1454 1444 89 142 - 8'-0" Concrete + Deck = 34.1 psf (Icr+Iu)/2 = 87 in4/ft Triple 15' - 3" 15' - 9" 16' - 7" 98 157 - Icr = 53.5 in4/ft Iu = 114.4 in4/ft 9'-0" Double 15' - 2" 16' - 7" 17' - 8" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 213 189 168 150 134 121 109 341 302 268 240 215 193 174 - Concrete + Deck = 33.8 psf (Icr+Iu)/2 = 83.9 in4/ft Vertical Load Span (in) Single 13' - 1" 13' - 6" 14' - 2" 36/4 1688 1514 1501 1490 120 192 - 109 174 - 99 158 - 90 144 - 82 132 - 75 121 - Attachment Pattern 1669 1653 1650 1503 1494 1497 1491 1482 1486 1480 1472 1476 1636 1489 1478 1468 1622 1481 1470 1461 1610 1473 1463 1454 1598 1466 1456 1448 1587 1460 1450 1442 Icr = 61.0 in4/ft Iu = 118.5 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 35.6 kip-in/ft ϕMno= 54.5 kip-in/ft Vn/Ω = 2.86 kip/ft ϕ Vn = 5.73 kip/ft www.ascsd.com TABLE OF CONTENTS 3WxH-36 Composite Deck 2.4 5" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.080yd3/100ft2 Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" 381 610 - ASD & LRFD - Superimposed Load, W (psf) 335 296 263 235 210 189 171 155 536 473 421 376 337 303 274 248 - 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 1927 1888 1854 1846 1817 1791 1644 1622 1602 1607 1590 1575 1623 1602 1583 1589 1573 1559 1606 1587 1569 1575 1560 1546 18 97 157 97 87 144 87 Attachment Pattern 1745 1725 1724 1548 1536 1543 1533 1522 1529 1522 1512 1519 1707 1532 1519 1509 1690 1522 1510 1500 1675 1513 1501 1492 1661 1505 1493 1484 1648 1497 1486 1477 Mno/Ω= 40.9 kip-in/ft ϕMno= 62.6 kip-in/ft 427 683 - ASD & LRFD - Superimposed Load, W (psf) 375 332 295 264 237 214 193 175 601 531 472 422 379 342 309 280 - 9'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 523 837 - 460 736 - 141 233 141 126 213 126 113 195 113 101 179 101 92 164 92 Attachment Pattern 1821 1798 1798 1593 1579 1589 1576 1563 1573 1565 1552 1563 1778 1576 1562 1551 1759 1565 1551 1541 1741 1554 1540 1531 1725 1544 1531 1522 1709 1535 1522 1513 Mno/Ω= 45.5 kip-in/ft ϕMno= 69.6 kip-in/ft 9'-0" Vn/Ω = 2.86 kip/ft ϕ Vn = 5.73 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 408 363 325 292 255 223 196 652 581 520 468 423 383 348 255 223 196 36/4 2020 1714 1680 1681 155 290 155 138 266 138 124 245 124 111 225 111 101 208 101 Attachment Pattern 1987 1957 1963 1694 1676 1693 1662 1645 1664 1662 1645 1664 1936 1676 1648 1649 1911 1661 1634 1634 1887 1647 1620 1621 1866 1633 1608 1608 1845 1621 1596 1596 Mno/Ω= 55.2 kip-in/ft ϕMno= 84.4 kip-in/ft Icr = 86.1 in4/ft Iu = 133.7 in4/ft Vn/Ω = 2.86 kip/ft ϕ Vn = 5.73 kip/ft D PANEL LRFD - Diaphragm Shear, ϕSn (plf / ft) 2253 2194 2142 2141 2096 2056 1831 1797 1767 1786 1759 1735 1785 1754 1727 1747 1723 1700 1786 1755 1727 1748 1723 1701 174 318 174 C PANELS 8'-0" 36/4 1846 1608 1591 1579 158 255 158 N PANELS Vertical Load Span (in) Vn/Ω = 2.86 kip/ft ϕ Vn = 5.73 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" Icr = 74.1 in4/ft Iu = 126.2 in4/ft Concrete + Deck = 35.5 psf (Icr+Iu)/2 = 110 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft 2720 2720 2720 6x6 W2.9xW2.9 As = 0.058 in2/ft 4070 4070 4070 6x6 W4.0xW4.0 As = 0.080 in2/ft 5060 5060 5060 4x4 W4xW4 As = 0.120 in2/ft 6860 6860 5170 4x4 W6xW6 As = 0.180 in2/ft 9560 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 107 171 - 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 2029 1984 1945 1938 1904 1874 PAF Base Steel ≥ .25" 1702 1676 1654 1662 1642 1624 PAF Base Steel ≥ 0.125" 1678 1654 1632 1642 1623 1606 #12 Screw Base Steel ≥ .0385" 1662 1638 1618 1628 1610 1593 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 117 187 - 8'-0" Concrete + Deck = 34.8 psf (Icr+Iu)/2 = 100 in4/ft 16 128 205 - B PANELS ASD, W/Ω LRFD, ϕW L/360 36/4 1767 1561 1545 1534 141 225 - Icr = 68.1 in4/ft Iu = 122.6 in4/ft Concrete + Deck = 34.6 psf (Icr+Iu)/2 = 95.3 in4/ft Vertical Load Span (in) 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 2W PANELS 19 8'-0" 3W PANELS GA GENERAL INFORMATION 73 TABLE OF CONTENTS 2.4 3WxH-36 Composite Deck 5 1⁄2" Total Slab Depth Light Weight Concrete (110 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.235yd3/100ft2 1 Hour Fire Rating Single 10' - 8" 11' - 8" 12' - 2" Maximum Unshored Span (in) Triple Gage 11' - 11" 19 12' - 9" 18 13' - 7" 16 Double 11' - 7" 12' - 4" 13' - 1" Vertical Load Span (in) 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 323 517 - 283 453 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2035 2010 1987 1978 1959 1942 1846 1832 1819 1818 1807 1797 1831 1818 1806 1806 1795 1786 1817 1805 1793 1794 1784 1776 ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 20 86 138 - 78 125 - 71 114 - Attachment Pattern 1912 1899 1895 1780 1773 1774 1770 1763 1765 1761 1754 1756 1884 1767 1758 1750 1874 1761 1753 1744 1864 1756 1747 1739 1855 1750 1742 1735 1846 1745 1737 1730 Mno/Ω= 35.3 kip-in/ft ϕMno= 54.1 kip-in/ft 355 568 - ASD & LRFD - Superimposed Load, W (psf) 311 274 243 217 194 174 157 142 498 439 389 347 310 279 251 227 - 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 385 616 - 338 540 - 36/4 1975 1817 1805 1794 128 205 - 116 186 - 106 169 - 96 154 - 88 141 - 80 128 - Attachment Pattern 1959 1944 1940 1807 1799 1801 1796 1787 1790 1785 1778 1781 1927 1793 1783 1774 1915 1786 1776 1767 1904 1779 1770 1761 1893 1773 1764 1756 1884 1767 1758 1751 Mno/Ω= 38.6 kip-in/ft ϕMno= 59.0 kip-in/ft Icr = 74.0 in4/ft Iu = 153.1 in4/ft 9'-0" Vn/Ω = 3.03 kip/ft ϕ Vn = 4.34 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2100 2070 2044 2035 2013 1993 1882 1865 1851 1851 1839 1827 1865 1850 1836 1837 1825 1814 1851 1836 1823 1825 1813 1803 Vn/Ω = 3.26 kip/ft ϕ Vn = 5.24 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 298 264 236 211 190 171 155 477 423 377 338 304 274 248 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2148 2115 2087 2077 2053 2031 1909 1891 1874 1876 1862 1849 1891 1874 1858 1861 1848 1836 1876 1859 1845 1848 1835 1824 Concrete + Deck = 38.8 psf (Icr+Iu)/2 = 117 in4/ft 74 95 152 - 8'-6" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 1926 1788 1778 1768 104 167 - 8'-0" Concrete + Deck = 38.7 psf (Icr+Iu)/2 = 114 in4/ft Triple 14' - 10" 15' - 4" 16' - 2" 115 185 - Icr = 68.9 in4/ft Iu = 150.4 in4/ft 9'-0" Double 14' - 7" 15' - 11" 17' - 2" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 249 221 196 175 157 141 128 399 353 314 281 252 226 204 - Concrete + Deck = 38.4 psf (Icr+Iu)/2 = 110 in4/ft Vertical Load Span (in) Single 12' - 8" 13' - 1" 13' - 9" 36/4 2012 1838 1825 1814 140 225 - 128 204 - 116 186 - 106 170 - 97 155 - 89 142 - Attachment Pattern 1994 1977 1974 1828 1818 1821 1815 1806 1810 1804 1796 1800 1960 1813 1802 1792 1946 1805 1794 1785 1934 1797 1787 1778 1922 1790 1780 1772 1911 1784 1774 1766 Icr = 78.6 in4/ft Iu = 155.6 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 41.6 kip-in/ft ϕMno= 63.6 kip-in/ft Vn/Ω = 3.26 kip/ft ϕ Vn = 6.04 kip/ft www.ascsd.com TABLE OF CONTENTS 5 1⁄2" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.235yd3/100ft2 1 Hour Fire Rating Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" 446 713 - ASD & LRFD - Superimposed Load, W (psf) 391 346 308 275 246 222 201 182 626 554 492 439 394 355 321 291 - 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2251 2213 2178 2170 2141 2115 1968 1946 1926 1931 1914 1899 1947 1926 1907 1913 1897 1883 1930 1911 1893 1899 1884 1870 18 115 184 - 106 169 - Attachment Pattern 2069 2049 2048 1872 1860 1867 1857 1846 1853 1846 1836 1843 2031 1856 1843 1833 2014 1846 1834 1824 1999 1837 1825 1816 1985 1829 1817 1808 1972 1821 1810 1801 Mno/Ω= 47.7 kip-in/ft ϕMno= 73.0 kip-in/ft 499 799 - ASD & LRFD - Superimposed Load, W (psf) 439 388 345 309 277 250 226 206 702 621 553 494 444 400 362 329 - 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 611 978 - 538 861 - 171 273 - 156 250 - 143 229 - 131 210 - 119 193 119 Attachment Pattern 2145 2122 2122 1917 1903 1913 1900 1887 1897 1889 1876 1887 2102 1900 1886 1875 2083 1889 1875 1865 2065 1878 1864 1855 2049 1868 1855 1846 2033 1859 1846 1837 Mno/Ω= 53.1 kip-in/ft ϕMno= 81.2 kip-in/ft Icr = 95.5 in4/ft Iu = 165.1 in4/ft 9'-0" Vn/Ω = 3.26 kip/ft ϕ Vn = 6.52 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 477 425 380 342 309 280 255 763 680 609 548 495 448 408 255 LRFD - Diaphragm Shear, ϕSn (plf / ft) 2577 2518 2466 2465 2420 2381 2155 2121 2091 2110 2083 2059 2109 2078 2051 2071 2047 2025 2110 2079 2051 2072 2047 2025 40.1 psf Icr = 110.8 in4/ft 4 143 in /ft Iu = 174.3 in4/ft 36/4 2344 2038 2004 2005 226 372 226 Attachment Pattern 2311 2281 2287 2018 2000 2017 1986 1969 1988 1986 1969 1988 Mno/Ω= 64.4 ϕMno= 98.5 144 264 144 131 244 131 2190 1957 1932 1932 Vn/Ω = 3.26 ϕ Vn = 6.52 2169 1945 1920 1921 kip/ft kip/ft D PANEL 8'-0" 36/4 2170 1932 1915 1903 187 299 - C PANELS Vertical Load Span (in) Vn/Ω = 3.26 kip/ft ϕ Vn = 6.52 kip/ft N PANELS 200 340 200 179 312 179 161 287 161 2260 2001 1972 1973 kip-in/ft kip-in/ft 2235 1985 1958 1958 2211 1971 1944 1945 LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft 3090 3090 3090 6x6 W2.9xW2.9 As = 0.058 in2/ft 4440 4440 4440 6x6 W4.0xW4.0 As = 0.080 in2/ft 5430 5430 5170 4x4 W4xW4 As = 0.120 in2/ft 7230 7230 5170 4x4 W6xW6 As = 0.180 in2/ft 9930 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 126 201 - 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 2353 2309 2269 2262 2228 2198 PAF Base Steel ≥ .25" 2026 2000 1978 1986 1966 1948 PAF Base Steel ≥ 0.125" 2002 1978 1956 1966 1947 1930 #12 Screw Base Steel ≥ .0385" 1986 1962 1942 1952 1934 1917 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = 137 220 - 8'-0" Concrete + Deck = 39.4 psf (Icr+Iu)/2 = 130 in4/ft 16 151 241 - B PANELS ASD, W/Ω LRFD, ϕW L/360 36/4 2091 1885 1869 1858 165 264 - Icr = 87.8 in4/ft Iu = 160.6 in4/ft Concrete + Deck = 39.2 psf (Icr+Iu)/2 = 124 in4/ft Vertical Load Span (in) 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 2W PANELS 19 8'-0" 3W PANELS GA 3WxH-36 Composite Deck 2.4 GENERAL INFORMATION 75 TABLE OF CONTENTS 2.4 3WxH-36 Composite Deck 6" Total Slab Depth Light Weight Concrete (110 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.389yd3/100ft2 Single 10' - 3" 11' - 2" 11' - 11" Maximum Unshored Span (in) Triple Gage 11' - 6" 19 12' - 4" 18 13' - 1" 16 Double 11' - 2" 11' - 11" 12' - 8" Vertical Load Span (in) 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 373 596 - 326 522 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2360 2334 2311 2302 2283 2266 2170 2156 2143 2142 2131 2121 2155 2142 2130 2130 2119 2110 2142 2129 2118 2118 2108 2100 ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 20 100 160 - 91 146 - 83 133 - Attachment Pattern 2236 2223 2219 2104 2097 2098 2094 2087 2089 2085 2078 2080 2208 2092 2082 2074 2198 2085 2077 2068 2188 2080 2071 2063 2179 2074 2066 2059 2170 2069 2062 2054 Mno/Ω= 40.6 kip-in/ft ϕMno= 62.2 kip-in/ft 409 655 - ASD & LRFD - Superimposed Load, W (psf) 359 317 281 250 224 201 181 164 574 507 449 401 359 322 290 262 - 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 444 710 - 390 623 - 36/4 2299 2141 2129 2118 149 238 - 135 216 - 123 196 - 112 179 - 102 163 - 93 149 - Attachment Pattern 2283 2268 2264 2131 2123 2125 2120 2111 2114 2109 2102 2105 2251 2117 2107 2098 2239 2110 2100 2091 2228 2103 2094 2085 2217 2097 2088 2080 2208 2091 2082 2075 Mno/Ω= 44.4 kip-in/ft ϕMno= 67.9 kip-in/ft Icr = 93.4 in4/ft Iu = 196.9 in4/ft 9'-0" Vn/Ω = 3.23 kip/ft ϕ Vn = 4.66 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2424 2394 2368 2359 2337 2317 2206 2190 2175 2175 2163 2151 2189 2174 2160 2161 2149 2138 2175 2160 2147 2149 2137 2127 Vn/Ω = 3.68 kip/ft ϕ Vn = 5.55 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 344 305 272 244 219 198 179 550 489 436 391 351 317 287 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2472 2439 2411 2401 2377 2355 2233 2215 2198 2200 2186 2174 2215 2198 2182 2185 2172 2160 2200 2183 2169 2172 2159 2148 Concrete + Deck = 43.3 psf (Icr+Iu)/2 = 150 in4/ft 76 110 176 - 8'-6" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 2250 2113 2102 2092 121 194 - 8'-0" Concrete + Deck = 43.3 psf (Icr+Iu)/2 = 145 in4/ft Triple 14' - 5" 14' - 11" 15' - 9" 134 214 - Icr = 87.0 in4/ft Iu = 193.6 in4/ft 9'-0" Double 14' - 1" 15' - 4" 16' - 9" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 288 255 227 203 182 164 148 460 408 363 324 291 262 236 - Concrete + Deck = 43.0 psf (Icr+Iu)/2 = 140 in4/ft Vertical Load Span (in) Single 12' - 4" 12' - 9" 13' - 5" 36/4 2336 2162 2149 2138 163 260 - 148 237 - 135 216 - 123 197 - 113 180 - 103 165 - Attachment Pattern 2318 2301 2298 2152 2142 2146 2139 2130 2134 2128 2120 2124 2284 2137 2126 2116 2270 2129 2118 2109 2258 2121 2111 2102 2246 2115 2105 2096 2235 2108 2098 2090 Icr = 99.3 in4/ft Iu = 199.9 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 47.8 kip-in/ft ϕMno= 73.2 kip-in/ft Vn/Ω = 3.68 kip/ft ϕ Vn = 6.35 kip/ft www.ascsd.com TABLE OF CONTENTS 3WxH-36 Composite Deck 2.4 6" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.389yd3/100ft2 Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" 514 823 - ASD & LRFD - Superimposed Load, W (psf) 452 399 355 317 285 257 232 210 723 639 568 508 456 410 371 337 - 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2575 2537 2502 2494 2465 2439 2292 2270 2250 2255 2238 2223 2271 2250 2231 2237 2221 2207 2255 2235 2217 2224 2208 2194 18 134 214 - 123 196 - Attachment Pattern 2393 2374 2372 2196 2185 2191 2181 2170 2177 2170 2160 2167 2355 2180 2167 2157 2339 2171 2158 2148 2323 2161 2149 2140 2309 2153 2141 2132 2296 2145 2134 2125 Mno/Ω= 54.9 kip-in/ft ϕMno= 84.0 kip-in/ft 577 923 - ASD & LRFD - Superimposed Load, W (psf) 507 449 399 357 321 289 262 238 811 718 639 571 513 463 419 381 - 9'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 706 1130 - 622 994 - 198 317 - 181 290 - 166 266 - 153 244 - 140 225 - Attachment Pattern 2469 2446 2446 2241 2227 2237 2225 2212 2222 2213 2201 2211 2426 2224 2210 2200 2407 2213 2199 2189 2389 2202 2189 2179 2373 2192 2179 2170 2357 2183 2170 2161 Mno/Ω= 61.2 kip-in/ft ϕMno= 93.6 kip-in/ft 9'-0" Vn/Ω = 3.68 kip/ft ϕ Vn = 7.35 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 551 491 440 396 358 324 295 881 785 704 633 572 519 472 36/4 2668 2362 2328 2329 247 394 - 226 362 - 204 333 204 184 307 184 166 283 166 Attachment Pattern 2635 2605 2611 2342 2324 2341 2310 2293 2312 2310 2294 2312 2584 2325 2296 2297 2559 2309 2282 2282 2535 2295 2268 2269 2514 2281 2256 2256 2493 2269 2244 2245 Mno/Ω= 74.2 kip-in/ft ϕMno= 113.6 kip-in/ft Icr = 140.1 in4/ft Iu = 223.0 in4/ft Vn/Ω = 3.68 kip/ft ϕ Vn = 7.35 kip/ft D PANEL LRFD - Diaphragm Shear, ϕSn (plf / ft) 2901 2842 2790 2789 2745 2705 2479 2445 2415 2434 2407 2383 2433 2402 2375 2395 2371 2349 2434 2403 2375 2396 2371 2349 269 431 - C PANELS 8'-0" 36/4 2494 2256 2239 2227 217 347 - N PANELS Vertical Load Span (in) Vn/Ω = 3.68 kip/ft ϕ Vn = 7.35 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" Icr = 120.7 in4/ft Iu = 211.7 in4/ft Concrete + Deck = 44.7 psf (Icr+Iu)/2 = 182 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft 3460 3460 3460 6x6 W2.9xW2.9 As = 0.058 in2/ft 4810 4810 4810 6x6 W4.0xW4.0 As = 0.080 in2/ft 5800 5800 5170 4x4 W4xW4 As = 0.120 in2/ft 7600 7600 5170 4x4 W6xW6 As = 0.180 in2/ft 10300 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 146 233 - 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 2678 2633 2593 2586 2552 2522 PAF Base Steel ≥ .25" 2350 2325 2302 2310 2290 2272 PAF Base Steel ≥ 0.125" 2326 2302 2280 2290 2271 2254 #12 Screw Base Steel ≥ .0385" 2310 2287 2266 2276 2258 2242 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 159 255 - 8'-0" Concrete + Deck = 44.0 psf (Icr+Iu)/2 = 166 in4/ft 16 174 279 - B PANELS ASD, W/Ω LRFD, ϕW L/360 36/4 2415 2209 2194 2182 191 306 - Icr = 110.9 in4/ft Iu = 206.1 in4/ft Concrete + Deck = 43.8 psf (Icr+Iu)/2 = 159 in4/ft Vertical Load Span (in) 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 2W PANELS 19 8'-0" 3W PANELS GA GENERAL INFORMATION 77 TABLE OF CONTENTS 2.4 3WxH-36 Composite Deck 6 1⁄4" Total Slab Depth Light Weight Concrete (110 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.466yd3/100ft2 2 Hour Fire Rating Single 10' - 1" 11' - 0" 11' - 9" Maximum Unshored Span (in) Triple Gage 11' - 4" 19 12' - 1" 18 12' - 10" 16 Double 10' - 11" 11' - 9" 12' - 5" Vertical Load Span (in) 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 398 637 - 349 558 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2522 2496 2473 2464 2445 2428 2332 2318 2305 2304 2293 2283 2317 2304 2292 2292 2281 2272 2304 2291 2280 2280 2270 2262 ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 20 107 171 - 98 156 - 89 142 - Attachment Pattern 2398 2385 2381 2266 2259 2260 2256 2249 2251 2247 2240 2242 2370 2254 2244 2236 2360 2247 2239 2231 2350 2242 2233 2225 2341 2236 2228 2221 2332 2231 2224 2216 Mno/Ω= 43.4 kip-in/ft ϕMno= 66.4 kip-in/ft 438 700 - ASD & LRFD - Superimposed Load, W (psf) 384 339 300 268 240 215 194 176 614 542 481 428 384 345 311 281 - 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 475 759 - 416 666 - 36/4 2461 2303 2291 2280 159 255 - 145 231 - 132 210 - 120 192 - 109 175 - 100 160 - Attachment Pattern 2445 2430 2427 2293 2285 2287 2282 2274 2276 2271 2264 2267 2413 2279 2269 2260 2401 2272 2262 2254 2390 2265 2256 2247 2379 2259 2250 2242 2370 2253 2245 2237 Mno/Ω= 47.4 kip-in/ft ϕMno= 72.5 kip-in/ft Icr = 104.2 in4/ft Iu = 221.7 in4/ft 9'-0" Vn/Ω = 3.34 kip/ft ϕ Vn = 4.82 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2586 2557 2530 2521 2499 2479 2368 2352 2337 2337 2325 2313 2351 2336 2322 2323 2311 2300 2337 2322 2309 2311 2299 2289 Vn/Ω = 3.89 kip/ft ϕ Vn = 5.71 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 368 327 291 261 235 212 192 588 522 466 418 376 339 307 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2634 2601 2573 2563 2539 2517 2395 2377 2360 2362 2348 2336 2377 2360 2344 2347 2334 2322 2362 2345 2331 2334 2321 2310 Concrete + Deck = 45.6 psf (Icr+Iu)/2 = 168 in4/ft 78 118 188 - 8'-6" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 2412 2275 2264 2254 130 208 - 8'-0" Concrete + Deck = 45.6 psf (Icr+Iu)/2 = 163 in4/ft Triple 14' - 3" 14' - 9" 15' - 7" 143 229 - Icr = 97.0 in4/ft Iu = 218.1 in4/ft 9'-0" Double 13' - 10" 15' - 1" 16' - 6" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 308 273 243 217 195 175 158 492 436 388 347 311 280 253 - Concrete + Deck = 45.3 psf (Icr+Iu)/2 = 158 in4/ft Vertical Load Span (in) Single 12' - 2" 12' - 7" 13' - 3" 36/4 2498 2324 2311 2300 174 279 - 158 254 - 144 231 - 132 211 - 121 193 - 110 177 - Attachment Pattern 2480 2463 2460 2314 2304 2308 2301 2292 2296 2290 2282 2286 2446 2299 2288 2278 2432 2291 2280 2271 2420 2283 2273 2264 2408 2277 2267 2258 2397 2270 2260 2252 Icr = 110.8 in4/ft Iu = 225.1 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 51.1 kip-in/ft ϕMno= 78.1 kip-in/ft Vn/Ω = 3.89 kip/ft ϕ Vn = 6.51 kip/ft www.ascsd.com TABLE OF CONTENTS 6 1⁄4" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.466yd3/100ft2 2 Hour Fire Rating Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" 550 880 - ASD & LRFD - Superimposed Load, W (psf) 483 427 380 339 305 275 248 225 773 684 608 543 488 439 397 360 - 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2737 2699 2664 2656 2627 2601 2454 2432 2412 2417 2400 2385 2433 2412 2393 2399 2383 2369 2417 2397 2379 2386 2370 2356 18 Attachment Pattern 2555 2536 2534 2358 2347 2353 2344 2333 2339 2332 2322 2329 2517 2342 2329 2319 2501 2333 2320 2310 2485 2323 2311 2302 2471 2315 2303 2294 2458 2307 2296 2287 Mno/Ω= 58.7 kip-in/ft ϕMno= 89.8 kip-in/ft 617 987 - ASD & LRFD - Superimposed Load, W (psf) 542 480 427 382 343 310 281 255 868 768 684 612 549 496 449 408 - 9'-0" 8'-0" 8'-6" 755 665 1209 1064 - 9'-0" Vn/Ω = 3.89 kip/ft ϕ Vn = 7.79 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 36/4 2656 2418 2401 2389 232 371 - 212 339 - 194 310 - 178 285 - 164 262 - 151 241 - Attachment Pattern 2631 2608 2608 2403 2389 2399 2387 2374 2384 2375 2363 2373 2588 2386 2372 2362 2569 2375 2361 2351 2551 2364 2351 2341 2535 2354 2341 2332 2519 2345 2332 2323 Mno/Ω= 65.4 kip-in/ft ϕMno= 100.1 kip-in/ft Icr = 134.8 in4/ft Iu = 238.1 in4/ft Vn/Ω = 3.89 kip/ft ϕ Vn = 7.79 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 589 525 471 424 383 347 316 943 841 753 678 613 556 506 36/4 2830 2524 2490 2491 289 462 - 264 423 - 242 388 - 223 357 - 205 329 - 186 303 186 Attachment Pattern 2797 2767 2773 2504 2486 2503 2472 2455 2474 2472 2456 2474 2746 2487 2458 2459 2721 2471 2444 2444 2697 2457 2430 2431 2676 2443 2418 2418 2655 2431 2406 2407 Mno/Ω= 79.4 kip-in/ft ϕMno= 121.4 kip-in/ft Icr = 156.5 in4/ft Iu = 250.6 in4/ft Vn/Ω = 3.89 kip/ft ϕ Vn = 7.79 kip/ft D PANEL LRFD - Diaphragm Shear, ϕSn (plf / ft) 3063 3004 2952 2951 2907 2867 2641 2607 2577 2596 2569 2545 2595 2564 2537 2557 2533 2511 2596 2565 2537 2558 2533 2511 Concrete + Deck = 47.0 psf (Icr+Iu)/2 = 204 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft n/a n/a n/a 6x6 W2.9xW2.9 As = 0.058 in2/ft 4990 4990 4990 6x6 W4.0xW4.0 As = 0.080 in2/ft 5980 5980 5170 4x4 W4xW4 As = 0.120 in2/ft 7780 7750 5170 4x4 W6xW6 As = 0.180 in2/ft 10480 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 132 211 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 143 229 - N PANELS 16 156 250 - 8'-6" Concrete + Deck = 46.3 psf (Icr+Iu)/2 = 186 in4/ft ASD, W/Ω LRFD, ϕW L/360 171 273 - 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 2840 2795 2755 2748 2714 2684 PAF Base Steel ≥ .25" 2512 2487 2464 2472 2452 2434 PAF Base Steel ≥ 0.125" 2488 2464 2443 2452 2433 2416 #12 Screw Base Steel ≥ .0385" 2472 2449 2428 2438 2420 2404 Vertical Load Span (in) 187 299 - B PANELS ASD, W/Ω LRFD, ϕW L/360 36/4 2577 2371 2356 2344 205 328 - Icr = 123.8 in4/ft Iu = 231.9 in4/ft Concrete + Deck = 46.1 psf (Icr+Iu)/2 = 178 in4/ft Vertical Load Span (in) 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 2W PANELS 19 8'-0" 3W PANELS GA 3WxH-36 Composite Deck 2.4 GENERAL INFORMATION 79 TABLE OF CONTENTS 2.4 3WxH-36 Composite Deck 7 3⁄16" Total Slab Depth Light Weight Concrete (110 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.755yd3/100ft2 3 Hour Fire Rating Single 9' - 5" 10' - 3" 11' - 1" Maximum Unshored Span (in) Triple Gage 10' - 8" 19 11' - 5" 18 12' - 1" 16 Double 10' - 4" 11' - 0" 11' - 9" Vertical Load Span (in) 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 498 797 - 437 699 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3129 3104 3081 3071 3052 3035 2940 2925 2913 2912 2901 2891 2925 2911 2899 2899 2889 2880 2911 2898 2887 2888 2878 2869 ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 20 135 217 - 124 198 - 113 180 - Attachment Pattern 3006 2993 2989 2874 2867 2868 2864 2857 2858 2854 2848 2850 2978 2861 2852 2844 2967 2855 2846 2838 2958 2849 2841 2833 2949 2844 2836 2828 2940 2839 2831 2824 Mno/Ω= 54.1 kip-in/ft ϕMno= 82.7 kip-in/ft 548 876 - ASD & LRFD - Superimposed Load, W (psf) 481 424 377 336 301 271 244 221 769 679 603 538 481 433 391 353 - 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 594 951 - 522 835 - 36/4 3069 2910 2898 2888 200 321 - 182 292 - 166 266 - 152 242 - 138 222 - 127 203 - Attachment Pattern 3052 3037 3034 2901 2892 2895 2889 2881 2884 2879 2871 2875 3021 2887 2877 2868 3009 2880 2870 2861 2998 2873 2864 2855 2987 2867 2858 2849 2977 2861 2852 2844 Mno/Ω= 59.1 kip-in/ft ϕMno= 90.4 kip-in/ft Icr = 151.3 in4/ft Iu = 334.2 in4/ft 9'-0" Vn/Ω = 3.77 kip/ft ϕ Vn = 5.46 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3194 3164 3138 3128 3106 3087 2976 2959 2944 2945 2932 2921 2959 2943 2929 2931 2919 2908 2944 2930 2916 2918 2907 2897 Vn/Ω = 4.43 kip/ft ϕ Vn = 6.35 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 461 410 366 328 295 267 241 737 655 585 525 472 426 386 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 3241 3209 3180 3171 3147 3125 3003 2984 2968 2970 2956 2943 2985 2967 2952 2954 2941 2929 2969 2953 2938 2942 2929 2918 Concrete + Deck = 54.2 psf (Icr+Iu)/2 = 250 in4/ft 80 149 238 - 8'-6" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 3020 2882 2871 2861 164 262 - 8'-0" Concrete + Deck = 54.2 psf (Icr+Iu)/2 = 243 in4/ft Triple 13' - 6" 14' - 2" 14' - 11" 180 288 - Icr = 140.7 in4/ft Iu = 329.1 in4/ft 9'-0" Double 13' - 1" 14' - 3" 15' - 10" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 385 341 304 272 244 220 199 616 546 487 436 391 352 318 - Concrete + Deck = 53.9 psf (Icr+Iu)/2 = 235 in4/ft Vertical Load Span (in) Single 11' - 9" 12' - 1" 12' - 9" 36/4 3105 2932 2918 2907 219 351 - 200 320 - 182 292 - 167 267 - 153 244 - 140 224 - Attachment Pattern 3087 3071 3068 2921 2912 2915 2909 2899 2904 2898 2889 2894 3053 2906 2895 2886 3040 2899 2888 2879 3027 2891 2881 2872 3016 2884 2874 2866 3005 2878 2868 2860 Icr = 161.0 in4/ft Iu = 338.9 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 63.7 kip-in/ft ϕMno= 97.5 kip-in/ft Vn/Ω = 4.75 kip/ft ϕ Vn = 7.15 kip/ft www.ascsd.com TABLE OF CONTENTS 7 3⁄16" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.755yd3/100ft2 3 Hour Fire Rating Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" 689 1103 - ASD & LRFD - Superimposed Load, W (psf) 606 536 477 426 383 345 312 284 969 858 763 682 613 552 500 454 - 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3345 3306 3272 3263 3234 3208 3061 3039 3020 3025 3008 2992 3040 3020 3001 3007 2991 2976 3024 3004 2987 2993 2978 2964 18 8'-6" 9'-0" 8'-0" 8'-6" 9'-0" Attachment Pattern 3163 3143 3142 2966 2954 2960 2951 2940 2947 2940 2929 2937 3124 2950 2937 2927 3108 2940 2928 2918 3093 2931 2919 2910 3079 2923 2911 2902 3066 2915 2904 2895 Mno/Ω= 73.3 kip-in/ft ϕMno= 112.2 kip-in/ft Vn/Ω = 4.75 kip/ft ϕ Vn = 8.61 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 36/4 3264 3026 3008 2996 293 469 - 268 428 - 245 392 - 225 360 - 207 331 - 191 305 - Attachment Pattern 3238 3215 3216 3011 2997 3006 2994 2981 2991 2983 2970 2981 3195 2994 2979 2969 3176 2982 2968 2959 3159 2972 2958 2949 3142 2962 2949 2940 3127 2953 2940 2931 Mno/Ω= 81.9 kip-in/ft ϕMno= 125.3 kip-in/ft Vn/Ω = 4.75 kip/ft ϕ Vn = 9.49 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 950 837 742 662 593 534 483 438 399 1520 1339 1187 1059 949 854 773 701 639 36/4 3438 3131 3098 3098 365 583 - 334 534 - 307 491 - 282 451 - 260 416 - 240 385 - Attachment Pattern 3405 3374 3381 3112 3093 3111 3080 3063 3082 3080 3063 3082 3354 3094 3066 3066 3328 3079 3052 3052 3305 3064 3038 3038 3283 3051 3026 3026 3263 3038 3014 3014 Mno/Ω= 99.6 kip-in/ft ϕMno= 152.3 kip-in/ft Icr = 228.6 in4/ft Iu = 375.1 in4/ft Vn/Ω = 4.75 kip/ft ϕ Vn = 9.49 kip/ft D PANEL LRFD - Diaphragm Shear, ϕSn (plf / ft) 3670 3612 3560 3558 3514 3474 3249 3215 3185 3203 3177 3153 3203 3172 3144 3165 3140 3118 3204 3172 3145 3165 3141 3119 Concrete + Deck = 55.6 psf (Icr+Iu)/2 = 302 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft n/a n/a n/a 6x6 W2.9xW2.9 As = 0.058 in2/ft 5680 5680 5170 6x6 W4.0xW4.0 As = 0.080 in2/ft 6670 6670 5170 4x4 W4xW4 As = 0.120 in2/ft 8470 7750 5170 4x4 W6xW6 As = 0.180 in2/ft 11170 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 167 267 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 181 290 - N PANELS 16 197 316 - Icr = 196.5 in4/ft Iu = 357.4 in4/ft Concrete + Deck = 54.9 psf (Icr+Iu)/2 = 277 in4/ft ASD, W/Ω LRFD, ϕW L/360 215 345 - ASD & LRFD - Superimposed Load, W (psf) 774 681 603 537 481 432 390 353 321 1239 1090 965 859 769 692 624 566 514 - LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 3447 3402 3362 3355 3322 3291 PAF Base Steel ≥ .25" 3120 3094 3071 3080 3060 3042 PAF Base Steel ≥ 0.125" 3096 3072 3050 3060 3041 3024 #12 Screw Base Steel ≥ .0385" 3079 3056 3035 3046 3028 3011 Vertical Load Span (in) 236 377 - B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" 36/4 3185 2978 2963 2951 258 413 - Icr = 180.1 in4/ft Iu = 348.7 in4/ft Concrete + Deck = 54.7 psf (Icr+Iu)/2 = 264 in4/ft Vertical Load Span (in) 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 2W PANELS 19 8'-0" 3W PANELS GA 3WxH-36 Composite Deck 2.4 GENERAL INFORMATION 81 TABLE OF CONTENTS 3.1 2WH-36 12" 12" 5" 5" 2-1/8" 2-1/8" 5" 5" 36" 36" 2WH-36 Profile 2WHS-36 Profile 36/4 36/4 Attachment Pattern 2W Series Embossment Panel Properties Gage Weight 22 21 20 19 18 16 w psf 1.57 1.78 1.89 2.25 2.51 3.14 Compression Gage Area 22 21 20 19 18 16 Ae in2/ft 0.315 0.383 0.419 0.551 0.650 0.882 Base Metal Thickness Yield Strength t in 0.029 0.033 0.035 0.042 0.047 0.059 Fy ksi 50 50 50 50 50 50 Tensile Strength Area Fu ksi 65 65 65 65 65 65 Ag in2/ft 0.448 0.509 0.540 0.647 0.722 0.903 Effective Section Modulus at Fy Bending Distance to Section N.A. from Section Modulus Bottom Modulus Se+ yb Sein3/ft in in3/ft 0.247 0.92 0.252 0.298 0.95 0.304 0.325 0.96 0.331 0.408 0.98 0.419 0.468 1.00 0.483 0.614 1.03 0.640 Gage 22 21 20 19 18 16 82 Condition 1" End 316 Interior 528 End 403 Interior 675 End 450 Interior 755 End 633 Interior 1066 End 781 Interior 1319 End 1194 Interior 2027 Web Crippling Constraints Ig in4/ft 0.353 0.403 0.427 0.510 0.567 0.703 yb in 1.04 1.04 1.05 1.05 1.05 1.05 Sg in3/ft 0.340 0.385 0.408 0.486 0.541 0.670 Radius of Gyration r in 0.890 0.889 0.880 0.887 0.886 0.883 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 1.18 1.15 1.14 1.11 1.10 1.07 Reactions at Supports (plf) Based on Web Crippling Allowable (Rn/Ω) 2" 4" 393 503 638 792 499 636 810 1001 556 707 903 1114 777 980 1266 1549 954 1199 1559 1898 1445 1800 2373 2862 h=2.16" Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Moment of Inertia Moment of Inertia Ie+ in4/ft 0.330 0.387 0.417 0.523 0.567 0.703 I ein4/ft 0.327 0.383 0.410 0.517 0.563 0.703 Bearing Length of Webs 6" 588 911 741 1148 822 1275 1137 1766 1387 2158 2072 3237 1" 483 786 616 1004 688 1123 968 1585 1195 1961 1827 3015 r=0.125" Composite and Non-Composite Deck Catalog • February 2016 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 0.338 0.392 0.420 0.519 0.567 0.703 Factored (ΦRn) 2" 4" 602 770 948 1178 764 973 1205 1489 851 1081 1344 1657 1188 1500 1883 2304 1460 1835 2318 2823 2211 2754 3530 4257 θ=64º Iin4/ft 0.336 0.390 0.416 0.514 0.564 0.703 6" 899 1355 1133 1708 1258 1897 1739 2627 2122 3211 3170 4815 www.ascsd.com TABLE OF CONTENTS 12" 5" 2-1/8" 36/4 5" GENERAL INFORMATION 2WHF-36 3.2 36/4 Attachment Pattern 36" 2WHF-36 Profile Gage Gage Area Ag in2/ft 1.008 1.147 1.299 1.193 1.332 1.484 1.381 1.520 1.671 Effective Section Modulus at Fy Bending Distance to N.A. from Bottom yb in 0.56 0.50 0.46 0.69 0.63 0.58 0.77 0.71 0.66 Section Modulus Sein3/ft 0.457 0.476 0.492 0.598 0.621 0.644 0.740 0.766 0.792 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 1.00 0.87 0.73 1.07 0.96 0.83 1.10 1.01 0.91 Moment of Inertia Ie + in4/ft 0.732 0.776 0.816 0.966 1.030 1.088 1.156 1.232 1.303 Moment of Inertia I ein4/ft 0.603 0.690 0.771 0.754 0.854 0.954 0.905 1.017 1.132 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 0.745 0.791 0.832 0.967 1.030 1.089 1.157 1.233 1.304 Iin4/ft 0.659 0.733 0.802 0.825 0.913 1.000 0.989 1.089 1.190 C PANELS Section Modulus Se+ in3/ft 0.391 0.401 0.406 0.596 0.605 0.614 0.779 0.792 0.803 Radius of Gyration r in 0.874 0.845 0.815 0.901 0.880 0.857 0.916 0.901 0.884 N PANELS 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Area Ae in2/ft 0.510 0.591 0.692 0.722 0.803 0.904 0.939 1.020 1.121 Tensile Strength Fu ksi 65 65 65 65 65 65 65 65 65 B PANELS Compression Base Metal Thickness Yield Strength t Fy in ksi 0.035 / 0.036 50 0.035 / 0.047 50 0.035 / 0.059 50 0.047 / 0.036 50 0.047 / 0.047 50 0.047 / 0.059 50 0.059 / 0.036 50 0.059 / 0.047 50 0.059 / 0.059 50 2W PANELS 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Weight w psf 3.49 3.96 4.48 4.11 4.58 5.10 4.74 5.21 5.73 Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Ig yb Sg in4/ft in in3/ft 0.770 0.65 0.496 0.820 0.58 0.504 0.864 0.53 0.510 0.968 0.73 0.653 1.032 0.66 0.663 1.090 0.61 0.672 1.159 0.79 0.809 1.235 0.73 0.822 1.306 0.68 0.833 3W PANELS Panel Properties D PANEL ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 83 TABLE OF CONTENTS 3.3 2WHF-36 Cellular Composite Deck Normal Weight Concrete (145 pcf) Maximum Unshored Spans 2WHF-36 Cellular Shoring Table Total Slab Depth (in) Volume cy/100sf 4 0.907 5 1.215 5 1/2 1 Hour Fire Rating 1.370 6 1/2 2 Hour Fire Rating 1.678 7 1/4 3 Hour Fire Rating 1.910 Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 145 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 39.1 9' - 9" 10' - 10" 39.6 9' - 10" 11' - 8" 40.1 9' - 10" 11' - 11" 39.8 12' - 1" 11' - 10" 40.3 12' - 3" 13' - 4" 40.8 12' - 4" 13' - 7" 40.4 12' - 9" 12' - 10" 40.9 12' - 11" 14' - 5" 41.4 13' - 1" 15' - 1" 51.2 8' - 10" 9' - 11" 51.7 8' - 11" 10' - 8" 52.2 8' - 11" 10' - 11" 51.9 11' - 4" 10' - 10" 52.3 11' - 5" 12' - 3" 52.9 11' - 6" 12' - 6" 52.5 12' - 0" 11' - 9" 53.0 12' - 2" 13' - 2" 53.5 12' - 3" 13' - 10" 57.2 8' - 6" 9' - 6" 57.7 8' - 6" 10' - 4" 58.2 8' - 7" 10' - 6" 57.9 10' - 11" 10' - 5" 58.4 11' - 0" 11' - 9" 58.9 11' - 0" 12' - 0" 58.6 11' - 8" 11' - 4" 59.0 11' - 10" 12' - 8" 59.6 12' - 0" 13' - 3" 69.3 7' - 11" 8' - 11" 69.8 7' - 11" 9' - 7" 70.3 8' - 0" 9' - 9" 70.0 10' - 2" 9' - 9" 70.5 10' - 2" 11' - 0" 71.0 10' - 3" 11' - 2" 70.7 11' - 2" 10' - 7" 71.1 11' - 4" 11' - 10" 71.7 11' - 6" 12' - 5" 78.4 7' - 6" 8' - 6" 78.9 7' - 7" 9' - 2" 79.4 7' - 8" 9' - 4" 79.0 9' - 8" 9' - 4" 79.5 9' - 9" 10' - 6" 80.0 9' - 9" 10' - 8" 79.7 10' - 9" 10' - 1" 80.2 10' - 11" 11' - 4" 80.7 11' - 1" 11' - 10" Triple 10' - 11" 10' - 11" 10' - 11" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 9' - 11" 10' - 0" 10' - 0" 12' - 3" 12' - 4" 12' - 4" 13' - 4" 13' - 4" 13' - 4" 9' - 7" 9' - 7" 9' - 8" 11' - 10" 11' - 10" 11' - 11" 13' - 0" 13' - 3" 13' - 4" 8' - 11" 9' - 0" 9' - 0" 11' - 0" 11' - 1" 11' - 1" 12' - 6" 12' - 8" 12' - 10" 8' - 6" 8' - 7" 8' - 7" 10' - 6" 10' - 7" 10' - 7" 12' - 1" 12' - 4" 12' - 5" Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span. 84 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 2WHF-36 Cellular Composite Deck 3.3 Light Weight Concrete (110 pcf) Maximum Unshored Spans Volume cy/100sf 4 0.907 1 Hour Fire Rating 1.215 2 Hour Fire Rating 1.292 3 Hour Fire Rating 1.582 D PANEL 6 3/16 C PANELS 5 1/4 N PANELS 5 1.061 Triple 11' - 10" 11' - 11" 11' - 11" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 11' - 4" 11' - 5" 11' - 5" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 10' - 11" 11' - 0" 11' - 0" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 10' - 9" 10' - 9" 10' - 10" 13' - 2" 13' - 3" 13' - 3" 13' - 4" 13' - 4" 13' - 4" 10' - 1" 10' - 1" 10' - 2" 12' - 5" 12' - 5" 12' - 6" 13' - 4" 13' - 4" 13' - 4" B PANELS 4 1/2 ACUSTADEK® Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 110 pcf Light Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 30.6 10' - 9" 11' - 10" 31.0 10' - 10" 12' - 9" 31.5 10' - 10" 13' - 0" 31.2 12' - 11" 12' - 11" 31.7 13' - 0" 14' - 6" 32.2 13' - 2" 14' - 10" 31.9 13' - 7" 14' - 0" 32.4 13' - 9" 15' - 8" 32.9 13' - 10" 16' - 5" 35.1 10' - 3" 11' - 4" 35.6 10' - 3" 12' - 2" 36.1 10' - 4" 12' - 5" 35.8 12' - 6" 12' - 4" 36.3 12' - 8" 13' - 11" 36.8 12' - 9" 14' - 2" 36.5 13' - 2" 13' - 5" 36.9 13' - 4" 15' - 0" 37.5 13' - 5" 15' - 8" 39.7 9' - 9" 10' - 10" 40.2 9' - 10" 11' - 9" 40.7 9' - 11" 11' - 11" 40.4 12' - 1" 11' - 11" 40.9 12' - 3" 13' - 5" 41.4 12' - 5" 13' - 8" 41.0 12' - 9" 12' - 10" 41.5 12' - 11" 14' - 5" 42.0 13' - 1" 15' - 1" 42.0 9' - 7" 10' - 8" 42.5 9' - 8" 11' - 6" 43.0 9' - 8" 11' - 9" 42.7 12' - 0" 11' - 8" 43.1 12' - 1" 13' - 2" 43.7 12' - 3" 13' - 5" 43.3 12' - 7" 12' - 8" 43.8 12' - 9" 14' - 2" 44.3 12' - 11" 14' - 10" 50.6 8' - 11" 10' - 0" 51.1 9' - 0" 10' - 10" 51.6 9' - 0" 11' - 0" 51.3 11' - 5" 11' - 0" 51.7 11' - 7" 12' - 4" 52.3 11' - 8" 12' - 7" 51.9 12' - 1" 11' - 10" 52.4 12' - 3" 13' - 4" 52.9 12' - 4" 13' - 11" 2W PANELS Total Slab Depth (in) 3W PANELS 2WHF-36 Cellular Shoring Table Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span. www.ascsd.com GENERAL INFORMATION Composite and Non-Composite Deck Catalog • February 2016 85 TABLE OF CONTENTS 3.3 2WH-36 Composite Deck 4" Total Slab Depth Normal Weight Concrete (145 pcf) Gage 22 21 20 GA 22 Concrete Volume 0.907yd3/100ft2 Single 7' - 11" 9' - 0" 9' - 6" Maximum Unshored Span (in) Triple Gage 9' - 5" 19 10' - 4" 18 10' - 10" 16 Double 8' - 9" 9' - 11" 10' - 6" Vertical Load Span (in) 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 395 632 - 332 532 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 7'-0" ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 2190 2024 2012 2000 7'-6" 8'-0" 8'-6" 98 157 - 87 140 - 78 125 - 70 111 - 62 100 - Attachment Pattern 2180 2162 2145 2024 2013 2004 2012 2002 1992 2000 1991 1982 2130 1995 1984 1974 2116 1987 1977 1967 2103 1979 1970 1961 2100 1981 1971 1963 2089 1974 1965 1957 Mno/Ω= 23.9 kip-in/ft ϕMno= 36.5 kip-in/ft 445 713 - ASD & LRFD - Superimposed Load, W (psf) 375 320 275 238 208 182 161 142 601 512 440 381 333 292 257 228 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2441 2413 2369 2332 2299 2270 2157 2150 2125 2104 2085 2069 2135 2130 2106 2087 2069 2054 2115 2112 2090 2071 2055 2040 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 470 752 - 396 634 - 9'-0" 36/4 2244 2054 2040 2027 7'-6" 8'-0" 8'-6" 9'-0" 127 203 - 113 181 - 101 161 - 90 145 - 81 130 - 73 117 - Attachment Pattern 2235 2214 2194 2055 2043 2032 2041 2030 2019 2029 2018 2008 2177 2021 2009 1999 2161 2012 2001 1991 2146 2003 1992 1983 2143 2006 1996 1986 2130 1998 1988 1979 Mno/Ω= 26.7 kip-in/ft ϕMno= 40.9 kip-in/ft 36/4 2272 2070 2054 2041 Vn/Ω = 3.02 kip/ft ϕ Vn = 4.52 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 338 291 252 220 193 171 151 540 465 403 352 309 273 242 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2481 2452 2406 2366 2331 2300 2178 2172 2146 2123 2103 2085 2155 2150 2126 2104 2086 2069 2135 2132 2109 2088 2071 2055 Vn/Ω = 3.02 kip/ft ϕ Vn = 4.52 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 25.4 in4/ft Iu = 59.4 in4/ft 7'-0" Triple 12' - 2" 12' - 8" 13' - 4" 110 176 - Icr = 23.1 in4/ft Iu = 58.3 in4/ft 7'-0" Double 11' - 9" 12' - 7" 14' - 2" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 6'-6" Concrete + Deck = 37.4 psf (Icr+Iu)/2 = 43.2 in4/ft 86 9'-0" 6'-0" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2362 2335 2298 2265 2237 2212 2115 2107 2086 2067 2051 2037 2095 2089 2069 2052 2037 2023 2077 2072 2054 2037 2023 2011 Concrete + Deck = 37.3 psf (Icr+Iu)/2 = 42.4 in4/ft 20 8'-0" ASD & LRFD - Superimposed Load, W (psf) 283 243 210 183 160 141 124 452 388 336 292 256 225 199 - Concrete + Deck = 37.1 psf (Icr+Iu)/2 = 40.7 in4/ft Vertical Load Span (in) 7'-6" Single 10' - 4" 10' - 8" 11' - 4" 134 215 - 120 192 - 107 172 - 96 154 - 87 139 - 78 125 - Attachment Pattern 2263 2240 2219 2071 2058 2046 2057 2044 2033 2044 2032 2021 2201 2035 2022 2012 2183 2025 2013 2003 2168 2016 2004 1994 2165 2019 2008 1999 2151 2011 2000 1991 Icr = 26.4 in4/ft Iu = 59.9 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 28.1 kip-in/ft ϕMno= 43.0 kip-in/ft Vn/Ω = 3.02 kip/ft ϕ Vn = 4.52 kip/ft www.ascsd.com TABLE OF CONTENTS 2WH-36 Composite Deck 3.3 4" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 0.907yd3/100ft2 Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-6" 555 888 - ASD & LRFD - Superimposed Load, W (psf) 469 400 345 300 262 231 204 182 750 640 552 480 420 370 327 291 - 7'-0" 18 130 209 - 118 188 - 106 170 - 96 154 - Attachment Pattern 2365 2337 2311 2131 2114 2099 2113 2098 2083 2100 2085 2071 2288 2086 2070 2059 2266 2073 2059 2048 2247 2062 2048 2037 2246 2068 2055 2045 2229 2058 2045 2035 Mno/Ω= 32.9 kip-in/ft ϕMno= 50.4 kip-in/ft 6'-6" 613 980 - ASD & LRFD - Superimposed Load, W (psf) 518 443 382 332 291 256 227 202 828 708 611 531 466 410 364 324 - 7'-0" 7'-6" 8'-0" 8'-6" 6'-0" 6'-6" 746 631 1193 1010 - 9'-0" 36/4 2448 2168 2147 2133 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 181 289 - 162 260 - 146 234 - 129 211 129 114 191 114 102 173 102 Attachment Pattern 2441 2409 2380 2176 2157 2140 2157 2139 2122 2143 2126 2110 2353 2124 2107 2095 2329 2109 2093 2082 2306 2096 2081 2070 2307 2105 2091 2080 2287 2093 2079 2069 Mno/Ω= 36.2 kip-in/ft ϕMno= 55.4 kip-in/ft 209 358 209 182 322 182 159 291 159 140 264 140 124 239 124 110 218 110 Attachment Pattern 2636 2594 2555 2294 2268 2245 2257 2234 2212 2256 2233 2211 2520 2224 2192 2192 2488 2205 2175 2174 2458 2187 2158 2157 2464 2204 2177 2176 2438 2188 2161 2161 Mno/Ω= 43.8 kip-in/ft ϕMno= 66.9 kip-in/ft Icr = 37.8 in4/ft Iu = 65.9 in4/ft Vn/Ω = 3.02 kip/ft ϕ Vn = 4.52 kip/ft D PANEL 36/4 2637 2276 2237 2236 Vn/Ω = 3.02 kip/ft ϕ Vn = 4.52 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 540 467 407 357 315 280 242 864 747 651 571 505 448 400 242 LRFD - Diaphragm Shear, ϕSn (plf / ft) 2996 2967 2882 2809 2744 2688 2453 2466 2417 2375 2337 2305 2396 2413 2368 2329 2294 2264 2394 2412 2366 2327 2293 2263 Vn/Ω = 3.02 kip/ft ϕ Vn = 4.52 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 32.5 in4/ft Iu = 63.0 in4/ft Concrete + Deck = 38.6 psf (Icr+Iu)/2 = 51.8 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft 3080 3080 3080 6x6 W2.9xW2.9 As = 0.058 in2/ft 4430 4430 4430 6x6 W4.0xW4.0 As = 0.080 in2/ft 5420 5420 5170 4x4 W4xW4 As = 0.120 in2/ft 7220 7220 5170 4x4 W6xW6 As = 0.180 in2/ft 9920 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 145 232 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 162 259 - N PANELS ASD, W/Ω LRFD, ϕW L/360 36/4 2373 2126 2108 2093 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 6'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 2731 2700 2635 2579 2530 2486 PAF Base Steel ≥ .25" 2311 2312 2275 2243 2215 2190 PAF Base Steel ≥ 0.125" 2280 2284 2249 2218 2192 2168 #12 Screw Base Steel ≥ .0385" 2259 2264 2230 2201 2176 2153 Vertical Load Span (in) 9'-0" Icr = 30.1 in4/ft Iu = 61.8 in4/ft Concrete + Deck = 38.0 psf (Icr+Iu)/2 = 47.7 in4/ft 16 8'-6" B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2625 2594 2537 2488 2445 2407 2255 2252 2220 2191 2167 2145 2227 2227 2196 2169 2146 2126 2206 2207 2178 2152 2130 2111 Concrete + Deck = 37.7 psf (Icr+Iu)/2 = 45.9 in4/ft Vertical Load Span (in) 7'-6" 2W PANELS 19 6'-0" 3W PANELS GA GENERAL INFORMATION 87 TABLE OF CONTENTS 3.3 2WH-36 Composite Deck 41⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.061yd3/100ft2 Single 7' - 7" 8' - 7" 9' - 0" Maximum Unshored Span (in) Triple Gage 8' - 11" 19 9' - 11" 18 10' - 4" 16 Double 8' - 4" 9' - 6" 10' - 0" Vertical Load Span (in) 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 477 763 - 401 642 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 7'-0" ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 2680 2515 2502 2490 7'-6" 8'-0" 8'-6" 119 191 - 106 170 - 95 152 - 85 136 - 76 122 - Attachment Pattern 2671 2652 2635 2514 2504 2494 2502 2492 2483 2491 2481 2473 2620 2485 2475 2465 2606 2477 2467 2458 2594 2470 2460 2451 2590 2471 2462 2453 2579 2465 2456 2447 Mno/Ω= 28.7 kip-in/ft ϕMno= 44.0 kip-in/ft 538 861 - ASD & LRFD - Superimposed Load, W (psf) 454 387 333 288 252 221 195 173 726 619 532 462 403 354 312 277 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2932 2903 2860 2822 2789 2760 2647 2640 2616 2594 2576 2559 2625 2620 2597 2577 2559 2544 2606 2602 2580 2562 2545 2530 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 568 908 - 479 766 - 9'-0" 36/4 2735 2545 2530 2517 7'-6" 8'-0" 8'-6" 9'-0" 154 246 - 137 220 - 123 197 - 110 176 - 99 158 - 89 142 - Attachment Pattern 2725 2704 2685 2546 2533 2522 2532 2520 2509 2520 2508 2498 2667 2512 2500 2489 2651 2502 2491 2481 2636 2494 2483 2473 2633 2496 2486 2477 2620 2489 2479 2470 Mno/Ω= 32.2 kip-in/ft ϕMno= 49.3 kip-in/ft 36/4 2763 2560 2545 2532 Vn/Ω = 3.51 kip/ft ϕ Vn = 5.26 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 408 352 305 267 234 207 184 654 563 488 426 375 331 294 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2972 2942 2896 2856 2821 2790 2668 2662 2636 2613 2593 2576 2645 2641 2616 2595 2576 2560 2625 2623 2599 2579 2561 2546 Vn/Ω = 3.51 kip/ft ϕ Vn = 5.04 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 34.7 in4/ft Iu = 83.7 in4/ft 7'-0" Triple 11' - 7" 12' - 3" 12' - 10" 134 214 - Icr = 31.5 in4/ft Iu = 82.3 in4/ft 7'-0" Double 11' - 2" 12' - 0" 13' - 8" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 6'-6" Concrete + Deck = 43.4 psf (Icr+Iu)/2 = 60.3 in4/ft 88 9'-0" 6'-0" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2853 2826 2788 2756 2727 2702 2605 2597 2576 2558 2542 2527 2586 2579 2559 2542 2527 2514 2568 2563 2544 2528 2514 2501 Concrete + Deck = 43.3 psf (Icr+Iu)/2 = 59.2 in4/ft 20 8'-0" ASD & LRFD - Superimposed Load, W (psf) 342 293 254 221 194 171 151 547 470 406 354 310 273 242 - Concrete + Deck = 43.1 psf (Icr+Iu)/2 = 56.9 in4/ft Vertical Load Span (in) 7'-6" Single 9' - 11" 10' - 2" 10' - 11" 163 262 - 146 234 - 131 209 - 118 188 - 106 169 - 95 152 - Attachment Pattern 2754 2731 2710 2562 2548 2536 2547 2535 2523 2535 2523 2512 2691 2525 2513 2502 2674 2515 2503 2493 2658 2506 2495 2485 2655 2510 2498 2489 2641 2501 2491 2482 Icr = 36.2 in4/ft Iu = 84.4 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 33.9 kip-in/ft ϕMno= 51.9 kip-in/ft Vn/Ω = 3.51 kip/ft ϕ Vn = 5.26 kip/ft www.ascsd.com TABLE OF CONTENTS 2WH-36 Composite Deck 3.3 41⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.061yd3/100ft2 Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 6'-6" 671 1074 - ASD & LRFD - Superimposed Load, W (psf) 567 485 418 363 318 280 248 221 908 775 669 581 509 448 397 353 - 7'-0" ASD, W/Ω LRFD, ϕW L/360 6'-0" 6'-6" 177 283 - 159 254 - 143 229 - 129 207 - 117 187 - Attachment Pattern 2855 2827 2801 2621 2605 2590 2604 2588 2574 2591 2575 2562 2778 2576 2561 2549 2757 2563 2549 2538 2737 2552 2538 2528 2736 2558 2545 2535 2719 2548 2535 2525 Mno/Ω= 39.8 kip-in/ft ϕMno= 60.8 kip-in/ft 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 6'-0" 6'-6" 36/4 2938 2658 2638 2623 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 220 352 - 197 316 - 178 285 - 161 257 - 145 233 - 132 211 - Attachment Pattern 2932 2899 2870 2667 2647 2630 2647 2629 2612 2633 2616 2600 2843 2614 2598 2586 2819 2600 2584 2573 2797 2587 2571 2561 2797 2596 2581 2571 2778 2584 2570 2560 Mno/Ω= 43.7 kip-in/ft ϕMno= 66.9 kip-in/ft Icr = 44.5 in4/ft Iu = 88.5 in4/ft 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 273 436 - 245 393 - 222 355 222 195 321 195 173 292 173 153 266 153 Attachment Pattern 3127 3084 3045 2784 2758 2735 2748 2724 2702 2747 2723 2702 3010 2714 2683 2682 2978 2695 2665 2664 2949 2677 2649 2648 2955 2694 2667 2666 2929 2678 2652 2651 Mno/Ω= 53.0 kip-in/ft ϕMno= 81.0 kip-in/ft Icr = 51.8 in4/ft Iu = 92.4 in4/ft Concrete + Deck = 44.7 psf (Icr+Iu)/2 = 72.1 in4/ft Vn/Ω = 3.51 kip/ft ϕ Vn = 5.26 kip/ft D PANEL 36/4 3128 2766 2728 2727 Vn/Ω = 3.51 kip/ft ϕ Vn = 5.26 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 904 765 655 567 494 434 383 341 304 1447 1225 1049 907 790 694 613 545 487 LRFD - Diaphragm Shear, ϕSn (plf / ft) 3486 3457 3372 3299 3235 3178 2944 2956 2907 2865 2828 2795 2886 2903 2858 2819 2785 2755 2885 2902 2857 2818 2784 2754 Vn/Ω = 3.51 kip/ft ϕ Vn = 5.26 kip/ft C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 197 315 - N PANELS ASD, W/Ω LRFD, ϕW L/360 36/4 2863 2616 2598 2584 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 742 627 536 463 403 353 311 276 246 1187 1003 858 740 644 565 498 442 393 - LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 3222 3190 3125 3069 3020 2977 PAF Base Steel ≥ .25" 2802 2803 2765 2733 2705 2680 PAF Base Steel ≥ 0.125" 2771 2774 2739 2709 2682 2659 #12 Screw Base Steel ≥ .0385" 2749 2754 2721 2692 2666 2643 Vertical Load Span (in) 9'-0" Icr = 41.2 in4/ft Iu = 86.9 in4/ft Concrete + Deck = 44.0 psf (Icr+Iu)/2 = 66.5 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft 3570 3570 3570 6x6 W2.9xW2.9 As = 0.058 in2/ft 4920 4920 4920 6x6 W4.0xW4.0 As = 0.080 in2/ft 5910 5910 5170 4x4 W4xW4 As = 0.120 in2/ft 7710 7710 5170 4x4 W6xW6 As = 0.180 in2/ft 10410 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 8'-6" B PANELS Vertical Load Span (in) 16 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 3116 3085 3028 2978 2935 2897 PAF Base Steel ≥ .25" 2745 2742 2710 2682 2657 2636 PAF Base Steel ≥ 0.125" 2717 2717 2686 2660 2637 2616 #12 Screw Base Steel ≥ .0385" 2696 2697 2668 2643 2621 2601 Concrete + Deck = 43.8 psf (Icr+Iu)/2 = 64.1 in4/ft 18 7'-6" 2W PANELS 19 6'-0" 3W PANELS GA GENERAL INFORMATION 89 TABLE OF CONTENTS 3.3 2WH-36 Composite Deck 5" Total Slab Depth Normal Weight Concrete (145 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.215yd3/100ft2 Single 7' - 3" 8' - 2" 8' - 8" Maximum Unshored Span (in) Triple Gage 8' - 7" 19 9' - 6" 18 9' - 10" 16 Double 8' - 1" 9' - 2" 9' - 7" Vertical Load Span (in) 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 563 900 - 474 759 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 7'-0" ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 3170 3005 2992 2980 7'-6" 8'-0" 8'-6" 142 226 - 126 202 - 113 181 - 101 162 - 91 145 - Attachment Pattern 3161 3143 3126 3005 2994 2984 2993 2982 2973 2981 2972 2963 3111 2976 2965 2955 3097 2968 2958 2948 3084 2960 2951 2942 3080 2962 2952 2944 3069 2955 2946 2938 Mno/Ω= 33.9 kip-in/ft ϕMno= 51.8 kip-in/ft 635 1017 - ASD & LRFD - Superimposed Load, W (psf) 536 457 393 341 298 262 231 205 858 731 629 546 477 419 370 328 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 3422 3393 3350 3313 3280 3251 3137 3131 3106 3085 3066 3050 3116 3110 3087 3067 3050 3034 3096 3093 3071 3052 3035 3021 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 671 1073 - 566 906 - 9'-0" 36/4 3225 3035 3021 3008 7'-6" 8'-0" 8'-6" 9'-0" 183 292 - 163 261 - 146 234 - 131 210 - 118 189 - 106 170 - Attachment Pattern 3216 3194 3175 3036 3024 3012 3022 3010 3000 3010 2999 2989 3157 3002 2990 2980 3141 2993 2981 2971 3127 2984 2973 2964 3124 2987 2976 2967 3111 2979 2969 2960 Mno/Ω= 38.0 kip-in/ft ϕMno= 58.1 kip-in/ft 36/4 3253 3051 3035 3022 Vn/Ω = 4.03 kip/ft ϕ Vn = 6.04 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 483 416 361 316 278 245 218 773 666 578 505 444 392 348 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 3462 3433 3387 3347 3311 3281 3159 3153 3126 3104 3084 3066 3136 3131 3107 3085 3066 3050 3116 3113 3090 3069 3052 3036 Vn/Ω = 3.78 kip/ft ϕ Vn = 5.43 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 45.8 in4/ft Iu = 114.1 in4/ft 7'-0" Triple 11' - 1" 11' - 10" 12' - 6" 159 254 - Icr = 41.6 in4/ft Iu = 112.3 in4/ft 7'-0" Double 10' - 9" 11' - 6" 13' - 2" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 6'-6" Concrete + Deck = 49.5 psf (Icr+Iu)/2 = 81.439 in4/ft 90 9'-0" 6'-0" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3343 3316 3279 3246 3218 3193 3095 3088 3066 3048 3032 3018 3076 3070 3050 3033 3018 3004 3058 3053 3034 3018 3004 2992 Concrete + Deck = 49.4 psf (Icr+Iu)/2 = 79.985 in4/ft 20 8'-0" ASD & LRFD - Superimposed Load, W (psf) 404 347 300 262 230 202 179 646 555 481 419 367 324 286 - Concrete + Deck = 49.2 psf (Icr+Iu)/2 = 76.942 in4/ft Vertical Load Span (in) 7'-6" Single 9' - 6" 9' - 9" 10' - 6" 194 310 - 174 278 - 156 249 - 140 224 - 126 202 - 114 182 - Attachment Pattern 3244 3221 3200 3052 3039 3027 3038 3025 3014 3025 3013 3002 3181 3016 3003 2992 3164 3006 2994 2983 3148 2997 2985 2975 3146 3000 2989 2979 3132 2992 2981 2972 Icr = 47.8 in4/ft Iu = 115.0 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 40.0 kip-in/ft ϕMno= 61.2 kip-in/ft Vn/Ω = 4.03 kip/ft ϕ Vn = 6.04 kip/ft www.ascsd.com TABLE OF CONTENTS 2WH-36 Composite Deck 3.3 5" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.215yd3/100ft2 Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-6" 7'-0" 18 6'-0" 6'-6" 7'-0" 189 302 - 171 273 - 154 247 - 140 224 - Attachment Pattern 3346 3318 3292 3112 3095 3080 3094 3079 3064 3081 3066 3052 3269 3066 3051 3040 3247 3054 3039 3028 3228 3042 3029 3018 3227 3049 3036 3025 3209 3038 3026 3016 Mno/Ω= 47.0 kip-in/ft ϕMno= 71.8 kip-in/ft 7'-6" 8'-0" 8'-6" 9'-0" 6'-0" 6'-6" 36/4 3429 3149 3128 3114 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 261 418 - 235 376 - 212 339 - 191 306 - 173 277 - 157 252 - Attachment Pattern 3422 3390 3360 3157 3138 3120 3138 3119 3103 3124 3106 3091 3334 3105 3088 3076 3309 3090 3074 3063 3287 3077 3062 3051 3288 3086 3071 3061 3268 3074 3060 3050 Mno/Ω= 51.7 kip-in/ft ϕMno= 79.1 kip-in/ft 324 519 - 292 468 - 264 423 - 239 383 - 218 348 - 198 317 - Attachment Pattern 3617 3574 3536 3274 3249 3226 3238 3214 3193 3237 3214 3192 3501 3205 3173 3173 3468 3185 3155 3155 3439 3168 3139 3138 3445 3185 3157 3157 3419 3169 3142 3142 Mno/Ω= 62.7 kip-in/ft ϕMno= 95.9 kip-in/ft Icr = 68.9 in4/ft Iu = 125.4 in4/ft Vn/Ω = 4.03 kip/ft ϕ Vn = 6.04 kip/ft D PANEL 36/4 3618 3257 3218 3217 Vn/Ω = 4.03 kip/ft ϕ Vn = 6.04 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1072 908 778 672 586 515 455 405 362 1715 1453 1244 1076 938 824 729 648 579 LRFD - Diaphragm Shear, ϕSn (plf / ft) 3977 3948 3863 3789 3725 3669 3434 3447 3398 3355 3318 3286 3377 3394 3349 3309 3275 3245 3375 3392 3347 3308 3274 3244 Vn/Ω = 4.03 kip/ft ϕ Vn = 6.04 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 59.0 in4/ft Iu = 120.4 in4/ft Concrete + Deck = 50.7 psf (Icr+Iu)/2 = 97.114 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft 4070 4070 4070 6x6 W2.9xW2.9 As = 0.058 in2/ft 5420 5420 5170 6x6 W4.0xW4.0 As = 0.080 in2/ft 6410 6410 5170 4x4 W4xW4 As = 0.120 in2/ft 8210 7750 5170 4x4 W6xW6 As = 0.180 in2/ft 10910 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 210 336 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 3354 3107 3088 3074 234 375 - N PANELS ASD, W/Ω LRFD, ϕW L/360 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 878 742 635 548 477 419 369 328 292 1404 1188 1016 877 764 670 591 524 467 - LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 3712 3681 3616 3560 3511 3467 PAF Base Steel ≥ .25" 3292 3293 3256 3224 3196 3171 PAF Base Steel ≥ 0.125" 3261 3265 3230 3199 3173 3149 #12 Screw Base Steel ≥ .0385" 3240 3245 3211 3182 3156 3134 Vertical Load Span (in) 9'-0" Icr = 54.6 in4/ft Iu = 118.2 in4/ft Concrete + Deck = 50.1 psf (Icr+Iu)/2 =89.703in4/ft 16 8'-6" B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3606 3575 3518 3469 3426 3388 3235 3233 3200 3172 3148 3126 3208 3207 3177 3150 3127 3107 3187 3188 3159 3133 3111 3092 Concrete + Deck = 49.8 psf (Icr+Iu)/2 =86.414in4/ft Vertical Load Span (in) 7'-6" ASD & LRFD - Superimposed Load, W (psf) 794 671 574 495 430 377 332 294 262 1271 1074 918 792 689 603 531 471 419 - 2W PANELS 19 6'-0" 3W PANELS GA GENERAL INFORMATION 91 TABLE OF CONTENTS 3.3 2WH-36 Composite Deck 5 1⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.370yd3/100ft2 1 Hour Fire Rating Single 7' - 0" 7' - 10" 8' - 3" Maximum Unshored Span (in) Triple Gage 8' - 3" 19 9' - 1" 18 9' - 6" 16 Double 7' - 9" 8' - 10" 9' - 2" Vertical Load Span (in) 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 652 1043 - 549 879 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 7'-0" ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" ASD, W/Ω LRFD, ϕW L/360 20 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 9'-0" 36/4 3661 3496 3483 3471 7'-6" 8'-0" 8'-6" 165 264 - 147 236 - 132 211 - 118 189 - 106 170 - Attachment Pattern 3652 3633 3616 3495 3484 3475 3483 3473 3464 3472 3462 3454 3601 3466 3456 3446 3587 3458 3448 3439 3575 3451 3441 3432 3571 3452 3443 3434 3560 3445 3437 3428 Mno/Ω= 39.1 kip-in/ft ϕMno= 59.9 kip-in/ft 6'-6" 736 1178 - ASD & LRFD - Superimposed Load, W (psf) 621 530 456 396 346 304 269 238 994 848 730 634 554 487 430 382 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 3913 3884 3841 3803 3770 3741 3628 3621 3597 3575 3557 3540 3606 3601 3578 3558 3540 3525 3587 3583 3561 3542 3526 3511 6'-0" 6'-6" 777 656 1244 1050 - 9'-0" 36/4 3716 3526 3511 3498 7'-6" 8'-0" 8'-6" 9'-0" 212 340 - 190 304 - 170 272 - 153 245 - 138 220 - 124 199 - Attachment Pattern 3706 3685 3666 3526 3514 3503 3513 3501 3490 3500 3489 3479 3648 3493 3481 3470 3632 3483 3472 3462 3617 3475 3464 3454 3614 3477 3467 3458 3601 3470 3460 3451 Mno/Ω= 43.9 kip-in/ft ϕMno= 67.2 kip-in/ft 36/4 3743 3541 3526 3513 Vn/Ω = 4.57 kip/ft ϕ Vn = 6.55 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 560 483 419 367 322 285 253 896 772 671 586 516 456 405 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 3953 3923 3877 3837 3802 3771 3649 3643 3617 3594 3574 2557 3626 3622 3597 3576 3557 3540 3606 3603 3580 3560 3542 3526 Vn/Ω = 4.06 kip/ft ϕ Vn = 5.84 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 58.8 in4/ft Iu = 151.4 in4/ft 7'-0" Triple 10' - 8" 11' - 5" 12' - 2" 185 296 - Icr = 53.4 in4/ft Iu = 149.0 in4/ft 7'-0" Double 10' - 4" 11' - 0" 12' - 8" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 6'-0" Concrete + Deck = 55.5 psf (Icr+Iu)/2 = 107 in4/ft 92 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3834 3807 3769 3737 3708 3683 3586 3578 3557 3539 3522 3508 3567 3560 3540 3523 3508 3495 3549 3544 3525 3509 3495 3482 Concrete + Deck = 55.4 psf (Icr+Iu)/2 = 105.12 in4/ft Vertical Load Span (in) 8'-0" ASD & LRFD - Superimposed Load, W (psf) 468 402 349 304 267 235 208 749 644 558 486 427 376 333 - Concrete + Deck = 55.2 psf (Icr+Iu)/2 = 101.21 in4/ft Vertical Load Span (in) 7'-6" Single 9' - 2" 9' - 5" 10' - 1" 226 361 - 202 323 - 181 290 - 163 261 - 147 235 - 133 213 - Attachment Pattern 3734 3711 3691 3543 3529 3517 3528 3515 3504 3516 3504 3493 3672 3506 3494 3483 3655 3496 3484 3474 3639 3487 3476 3466 3636 3490 3479 3470 3622 3482 3472 3462 Icr = 61.4 in4/ft Iu = 152.6 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 46.3 kip-in/ft ϕMno= 70.8 kip-in/ft Vn/Ω = 4.57 kip/ft ϕ Vn = 6.86 kip/ft www.ascsd.com TABLE OF CONTENTS 2WH-36 Composite Deck 3.3 5 1⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.370yd3/100ft2 1 Hour Fire Rating Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-6" 7'-0" 18 6'-0" 6'-6" 7'-0" 220 353 - 199 318 - 180 288 - 163 261 - Attachment Pattern 3836 3808 3782 3602 3586 3570 3585 3569 3555 3571 3556 3543 3759 3557 3542 3530 3738 3544 3530 3519 3718 3533 3519 3508 3717 3539 3526 3516 3700 3529 3516 3506 Mno/Ω= 54.4 kip-in/ft ϕMno= 83.2 kip-in/ft 7'-6" 8'-0" 8'-6" 9'-0" 6'-0" 6'-6" 36/4 3919 3639 3619 3604 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 304 487 - 274 438 - 247 395 - 223 357 - 202 324 - 184 294 - Attachment Pattern 3913 3880 3851 3647 3628 3611 3628 3610 3593 3614 3597 3581 3824 3595 3578 3567 3800 3581 3565 3553 3778 3568 3552 3541 3778 3577 3562 3552 3758 3565 3550 3541 Mno/Ω= 59.9 kip-in/ft ϕMno= 91.7 kip-in/ft 378 606 - 341 546 - 308 494 - 280 448 - 255 407 - 232 371 - Attachment Pattern 4108 4065 4026 3765 3739 3716 3729 3705 3683 3728 3704 3682 3991 3695 3664 3663 3959 3676 3646 3645 3929 3658 3629 3629 3936 3675 3648 3647 3910 3659 3633 3632 Mno/Ω= 72.8 kip-in/ft ϕMno= 111.4 kip-in/ft Icr = 88.9 in4/ft Iu = 165.7 in4/ft Vn/Ω = 4.57 kip/ft ϕ Vn = 6.86 kip/ft D PANEL 36/4 4109 3747 3709 3708 Vn/Ω = 4.57 kip/ft ϕ Vn = 6.86 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1247 1056 905 783 683 600 531 472 422 1995 1690 1448 1252 1092 960 849 755 675 LRFD - Diaphragm Shear, ϕSn (plf / ft) 4467 4438 4353 4280 4216 4159 3925 3937 3888 3846 3809 3776 3867 3884 3839 3800 3766 3736 3866 3883 3838 3799 3765 3735 Vn/Ω = 4.57 kip/ft ϕ Vn = 6.86 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 76.0 in4/ft Iu = 159.3 in4/ft Concrete + Deck = 56.8 psf (Icr+Iu)/2 =127.28in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft n/a n/a n/a 6x6 W2.9xW2.9 As = 0.058 in2/ft 5910 5910 5170 6x6 W4.0xW4.0 As = 0.080 in2/ft 6900 6900 5170 4x4 W4xW4 As = 0.120 in2/ft 8700 7750 5170 4x4 W6xW6 As = 0.180 in2/ft 11400 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 245 392 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 3844 3597 3579 3565 273 436 - N PANELS ASD, W/Ω LRFD, ϕW L/360 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1019 862 738 637 555 487 430 381 340 1631 1380 1180 1019 888 779 687 610 544 - LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 4202 4171 4106 4050 4001 3958 PAF Base Steel ≥ .25" 3782 3783 3746 3714 3686 3661 PAF Base Steel ≥ 0.125" 3752 3755 3720 3690 3663 3640 #12 Screw Base Steel ≥ .0385" 3730 3735 3702 3672 3647 3624 Vertical Load Span (in) 9'-0" Icr = 70.3 in4/ft Iu = 156.6 in4/ft Concrete + Deck = 56.1 psf (Icr+Iu)/2 = 117.68 in4/ft 16 8'-6" B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 4097 4065 4009 3959 3916 3878 3726 3723 3691 3663 3638 3616 3698 3698 3667 3641 3617 3597 3677 3678 3649 3624 3602 3582 Concrete + Deck = 55.9 psf (Icr+Iu)/2 = 113.42 in4/ft Vertical Load Span (in) 7'-6" ASD & LRFD - Superimposed Load, W (psf) 921 779 666 575 500 438 386 342 305 1474 1246 1065 919 800 701 618 548 488 - 2W PANELS 19 6'-0" 3W PANELS GA GENERAL INFORMATION 93 TABLE OF CONTENTS 3.3 2WH-36 Composite Deck 6 1⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Gage 22 21 20 GA Concrete Volume 1.687yd3/100ft2 2 Hour Fire Rating Single 6' - 6" 7' - 4" 7' - 8" Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 22 Maximum Unshored Span (in) Triple Gage 7' - 8" 19 8' - 6" 18 8' - 10" 16 Double 7' - 4" 8' - 2" 8' - 6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-0" 6'-6" 836 705 1337 1127 - 7'-0" ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" ASD, W/Ω LRFD, ϕW L/360 20 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-0" 6'-6" 9'-0" 36/4 4642 4477 4464 4452 7'-6" 8'-0" 8'-6" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 4893 4865 4821 4784 4751 4722 4609 4602 4577 4556 4538 4521 4587 4582 4559 4539 4521 4506 4568 4564 4542 4523 4507 4492 6'-0" 6'-6" 36/4 4696 4507 4492 4479 213 341 - 191 305 - 171 274 - 154 246 - 138 221 - Attachment Pattern 4632 4614 4597 4476 4465 4456 4464 4454 4445 4452 4443 4434 4582 4447 4436 4427 4568 4439 4429 4419 4555 4432 4422 4413 4552 4433 4424 4415 4541 4426 4417 4409 Mno/Ω= 50.0 kip-in/ft ϕMno= 76.6 kip-in/ft 7'-6" 8'-0" 8'-6" 9'-0" 275 439 - 246 393 - 220 353 - 198 317 - 179 286 - 161 258 - Attachment Pattern 4687 4666 4646 4507 4495 4484 4494 4482 4471 4481 4470 4460 4629 4473 4462 4451 4613 4464 4453 4443 4598 4456 4445 4435 4595 4458 4448 4438 4582 4450 4440 4432 Mno/Ω= 56.2 kip-in/ft ϕMno= 86.0 kip-in/ft 36/4 4724 4522 4507 4493 Vn/Ω = 5.16 kip/ft ϕ Vn = 7.42 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 999 843 720 621 540 472 416 368 327 1598 1349 1152 993 863 755 665 589 523 LRFD - Diaphragm Shear, ϕSn (plf / ft) 4934 4904 4858 4818 4783 4752 4630 4624 4598 4575 4555 4538 4607 4603 4578 4557 4538 4521 4587 4584 4561 4541 4523 4507 Vn/Ω = 4.64 kip/ft ϕ Vn = 6.71 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 90.6 in4/ft Iu = 249.5 in4/ft 7'-0" Triple 9' - 11" 10' - 8" 11' - 7" 239 382 - Icr = 82.0 in4/ft Iu = 245.9 in4/ft 7'-0" Double 9' - 7" 10' - 3" 11' - 10" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 945 798 681 587 509 446 392 347 308 1512 1277 1090 939 815 713 627 555 493 - Concrete + Deck = 67.6 psf (Icr+Iu)/2 = 173 in4/ft 94 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) 4814 4787 4750 4718 4689 4664 4567 4559 4538 4519 4503 4489 4547 4541 4521 4504 4489 4476 4529 4524 4506 4490 4475 4463 Concrete + Deck = 67.5 psf (Icr+Iu)/2 = 170 in4/ft Vertical Load Span (in) 8'-0" ASD & LRFD - Superimposed Load, W (psf) 601 517 448 391 343 303 269 961 827 717 626 549 485 430 - Concrete + Deck = 67.3 psf (Icr+Iu)/2 = 164 in4/ft Vertical Load Span (in) 7'-6" Single 8' - 7" 8' - 10" 9' - 6" 292 467 - 262 418 - 235 376 - 212 339 - 191 306 - 173 277 - Attachment Pattern 4715 4692 4672 4524 4510 4498 4509 4496 4485 4496 4484 4474 4653 4487 4475 4464 4636 4477 4465 4455 4620 4468 4456 4447 4617 4471 4460 4451 4603 4463 4452 4443 Icr = 94.7 in4/ft Iu = 251.2 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 59.3 kip-in/ft ϕMno= 90.7 kip-in/ft Vn/Ω = 5.45 kip/ft ϕ Vn = 7.81 kip/ft www.ascsd.com TABLE OF CONTENTS 2WH-36 Composite Deck 3.3 6 1⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.987yd3/100ft2 2 Hour Fire Rating Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-6" 7'-0" 18 6'-0" 6'-6" 7'-0" 286 457 - 258 413 - 234 374 - 212 340 - Attachment Pattern 4817 4789 4763 4583 4566 4551 4566 4550 4536 4552 4537 4523 4740 4538 4523 4511 4719 4525 4511 4500 4699 4514 4500 4489 4698 4520 4507 4497 4681 4510 4497 4487 Mno/Ω= 69.8 kip-in/ft ϕMno= 106.8 kip-in/ft 7'-6" 8'-0" 8'-6" 9'-0" 6'-0" 6'-6" 36/4 4900 4620 4600 4585 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 394 631 - 355 568 - 320 512 - 290 464 - 263 421 - 239 383 - Attachment Pattern 4893 4861 4832 4628 4609 4592 4609 4591 4574 4595 4578 4562 4805 4576 4559 4547 4781 4562 4546 4534 4758 4548 4533 4522 4759 4558 4543 4532 4739 4546 4531 4521 Mno/Ω= 77.1 kip-in/ft ϕMno= 117.9 kip-in/ft 491 786 - 443 709 - 401 642 - 364 583 - 332 530 - 303 484 - Attachment Pattern 5088 5046 5007 4746 4720 4697 4710 4686 4664 4709 4685 4663 4972 4676 4645 4644 4940 4657 4627 4626 4910 4639 4610 4610 4917 4656 4629 4628 4890 4640 4613 4613 Mno/Ω= 93.9 kip-in/ft ϕMno= 143.7 kip-in/ft Icr = 138.2 in4/ft Iu = 271.2 in4/ft Vn/Ω = 5.74 kip/ft ϕ Vn = 8.61 kip/ft D PANEL 36/4 5090 4728 4690 4689 Vn/Ω = 5.74 kip/ft ϕ Vn = 8.61 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1611 1365 1170 1013 884 777 687 612 547 2578 2185 1872 1620 1414 1243 1100 979 875 LRFD - Diaphragm Shear, ϕSn (plf / ft) 5448 5419 5334 5261 5197 5140 4905 4918 4869 4827 4790 4757 4848 4865 4820 4781 4747 4716 4847 4864 4819 4780 4745 4715 Vn/Ω = 5.74 kip/ft ϕ Vn = 8.61 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 117.7 in4/ft Iu = 261.5 in4/ft Concrete + Deck = 68.8 psf (Icr+Iu)/2 = 205 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft n/a n/a n/a 6x6 W2.9xW2.9 As = 0.058 in2/ft 6890 6890 5170 6x6 W4.0xW4.0 As = 0.080 in2/ft 7880 7750 5170 4x4 W4xW4 As = 0.120 in2/ft 9680 7750 5170 4x4 W6xW6 As = 0.180 in2/ft 12380 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 317 507 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 4825 4578 4560 4546 353 565 - N PANELS ASD, W/Ω LRFD, ϕW L/360 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1313 1111 951 822 716 629 555 493 440 2101 1778 1522 1315 1146 1006 888 789 704 - LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 5183 5152 5087 5031 4982 4939 PAF Base Steel ≥ .25" 4763 4764 4727 4695 4667 4642 PAF Base Steel ≥ 0.125" 4733 4736 4701 4671 4644 4620 #12 Screw Base Steel ≥ .0385" 4711 4716 4682 4653 4628 4605 Vertical Load Span (in) 9'-0" Icr = 108.6 in4/ft Iu = 257.3 in4/ft Concrete + Deck = 68.2 psf (Icr+Iu)/2 = 190 in4/ft 16 8'-6" B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 5077 5046 4989 4940 4897 4859 4707 4704 4672 4644 4619 4597 4679 4679 4648 4622 4598 4578 4658 4659 4630 4605 4582 4563 Concrete + Deck = 68.0 psf (Icr+Iu)/2 = 183 in4/ft Vertical Load Span (in) 7'-6" ASD & LRFD - Superimposed Load, W (psf) 1186 1003 858 740 645 565 499 442 394 1897 1604 1372 1185 1031 904 798 708 631 - 2W PANELS 19 6'-0" 3W PANELS GA GENERAL INFORMATION 95 TABLE OF CONTENTS 3.3 2WH-36 Composite Deck 7 1⁄4" Total Slab Depth Normal Weight Concrete (145 pcf) Gage 22 21 20 GA Concrete Volume 1.910yd3/100ft2 3 Hour Fire Rating Single 6' - 3" 7' - 0" 7' - 4" Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 22 Maximum Unshored Span (in) Triple Gage 7' - 3" 19 8' - 1" 18 8' - 5" 16 Double 7' - 0" 7' - 10" 8' - 2" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-0" 6'-6" 7'-0" ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" ASD, W/Ω LRFD, ϕW L/360 20 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-0" 6'-6" 9'-0" 36/4 5377 5212 5199 5187 7'-6" 8'-0" 8'-6" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 5629 5600 5557 5520 5487 5458 5344 5338 5313 5292 5273 5257 5322 5317 5294 5274 5257 5241 5303 5300 5278 5259 5242 5228 6'-0" 6'-6" 36/4 5432 5242 5228 5215 251 401 - 224 359 - 201 322 - 181 290 - 163 261 - Attachment Pattern 5368 5350 5333 5212 5201 5191 5199 5189 5180 5188 5179 5170 5318 5183 5172 5162 5304 5175 5164 5155 5291 5167 5158 5149 5287 5169 5159 5151 5276 5162 5153 5145 Mno/Ω= 58.4 kip-in/ft ϕMno= 89.4 kip-in/ft 7'-6" 8'-0" 8'-6" 9'-0" 323 516 - 289 462 - 259 415 - 233 374 - 211 337 - 190 305 - Attachment Pattern 5423 5401 5382 5243 5231 5219 5229 5217 5207 5217 5206 5196 5364 5209 5197 5187 5348 5200 5188 5178 5334 5191 5180 5171 5330 5194 5183 5174 5318 5186 5176 5167 Mno/Ω= 65.7 kip-in/ft ϕMno= 100.5 kip-in/ft 36/4 5460 5258 5242 5229 Vn/Ω = 5.63 kip/ft ϕ Vn = 8.13 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1169 988 844 728 632 554 488 432 384 1871 1580 1350 1164 1012 886 780 691 615 LRFD - Diaphragm Shear, ϕSn (plf / ft) 5669 5640 5594 5553 5518 5487 5366 5360 5333 5311 5291 5273 5343 5338 5314 5292 5273 5257 5323 5320 5297 5276 5259 5243 Vn/Ω = 5.11 kip/ft ϕ Vn = 7.42 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 119.4 in4/ft Iu = 346.6 in4/ft 7'-0" Triple 9' - 5" 10' - 2" 11' - 3" 281 449 - Icr = 108.0 in4/ft Iu = 342.0 in4/ft 7'-0" Double 9' - 2" 9' - 10" 11' - 3" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1106 934 797 687 597 522 460 407 361 1770 1494 1276 1100 955 836 736 651 578 - Concrete + Deck = 76.7 psf (Icr+Iu)/2 = 237 in4/ft 96 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) 5550 5523 5486 5453 5425 5400 5302 5294 5273 5255 5239 5225 5283 5277 5257 5240 5225 5211 5265 5260 5241 5225 5211 5199 Concrete + Deck = 76.6 psf (Icr+Iu)/2 = 233 in4/ft Vertical Load Span (in) 8'-0" ASD & LRFD - Superimposed Load, W (psf) 978 824 703 605 525 458 403 356 315 1564 1319 1125 968 840 733 644 569 504 - Concrete + Deck = 76.3 psf (Icr+Iu)/2 = 225 in4/ft Vertical Load Span (in) 7'-6" Single 8' - 3" 8' - 6" 9' - 2" 343 549 - 307 492 - 276 442 - 249 399 - 225 360 - 204 326 - Attachment Pattern 5451 5428 5407 5259 5246 5234 5245 5232 5221 5232 5220 5209 5388 5223 5210 5199 5371 5213 5201 5190 5355 5204 5192 5182 5353 5207 5196 5186 5339 5199 5188 5179 Icr = 124.9 in4/ft Iu = 348.9 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 69.3 kip-in/ft ϕMno= 106.0 kip-in/ft Vn/Ω = 5.92 kip/ft ϕ Vn = 8.52 kip/ft www.ascsd.com TABLE OF CONTENTS 2WH-36 Composite Deck 3.3 7 1⁄4" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.910yd3/100ft2 3 Hour Fire Rating Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-6" 7'-0" 18 6'-0" 6'-6" 7'-0" 336 538 - 304 487 - 276 441 - 251 401 - Attachment Pattern 5553 5524 5499 5319 5302 5287 5301 5286 5271 5288 5273 5259 5475 5273 5258 5247 5454 5261 5246 5235 5435 5249 5236 5225 5434 5256 5242 5232 5416 5245 5233 5223 Mno/Ω= 81.7 kip-in/ft ϕMno= 125.1 kip-in/ft 7'-6" 8'-0" 8'-6" 9'-0" 6'-0" 6'-6" 36/4 5636 5356 5335 5321 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 464 742 - 418 668 - 377 603 - 342 547 - 310 497 - 283 452 - Attachment Pattern 5629 5597 5567 5364 5345 5327 5345 5326 5310 5331 5313 5298 5541 5312 5295 5283 5516 5297 5281 5270 5494 5284 5269 5258 5495 5293 5278 5268 5475 5281 5267 5257 Mno/Ω= 90.3 kip-in/ft ϕMno= 138.1 kip-in/ft 579 926 - 522 836 - 473 757 - 430 687 - 391 626 - 357 572 - Attachment Pattern 5824 5781 5743 5481 5456 5433 5445 5421 5400 5444 5420 5399 5707 5412 5380 5379 5675 5392 5362 5362 5646 5375 5346 5345 5652 5392 5364 5364 5626 5376 5349 5348 Mno/Ω= 110.2 kip-in/ft ϕMno= 168.6 kip-in/ft Icr = 183.6 in4/ft Iu = 375.1 in4/ft Vn/Ω = 6.68 kip/ft ϕ Vn = 10.02 kip/ft D PANEL 36/4 5825 5463 5425 5424 Vn/Ω = 6.68 kip/ft ϕ Vn = 10.02 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1894 1605 1376 1191 1040 914 809 720 644 3030 2568 2201 1905 1663 1463 1295 1152 1031 LRFD - Diaphragm Shear, ϕSn (plf / ft) 6184 6154 6070 5996 5932 5876 5641 5654 5605 5562 5525 5493 5584 5601 5556 5516 5482 5452 5582 5599 5554 5515 5481 5451 Vn/Ω = 6.68 kip/ft ϕ Vn = 9.59 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 155.9 in4/ft Iu = 362.3 in4/ft Concrete + Deck = 77.9 psf (Icr+Iu)/2 = 279 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft n/a n/a n/a 6x6 W2.9xW2.9 As = 0.058 in2/ft 7630 7630 5170 6x6 W4.0xW4.0 As = 0.080 in2/ft 8620 7750 5170 4x4 W4xW4 As = 0.120 in2/ft 10420 7750 5170 4x4 W6xW6 As = 0.180 in2/ft 13120 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 373 597 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 5561 5314 5295 5281 415 664 - N PANELS ASD, W/Ω LRFD, ϕW L/360 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1540 1304 1116 965 841 739 652 580 517 2465 2086 1786 1544 1346 1182 1044 927 828 - LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 5919 5888 5823 5767 5718 5674 PAF Base Steel ≥ .25" 5499 5500 5463 5431 5403 5378 PAF Base Steel ≥ 0.125" 5468 5472 5437 5406 5380 5356 #12 Screw Base Steel ≥ .0385" 5447 5452 5418 5389 5363 5341 Vertical Load Span (in) 9'-0" Icr = 143.6 in4/ft Iu = 356.9 in4/ft Concrete + Deck = 77.3 psf (Icr+Iu)/2 = 259 in4/ft 16 8'-6" B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 5813 5782 5725 5676 5633 5595 5442 5440 5407 5379 5355 5333 5415 5414 5384 5357 5334 5314 5394 5395 5366 5340 5318 5299 Concrete + Deck = 77.0 psf (Icr+Iu)/2 = 250 in4/ft Vertical Load Span (in) 7'-6" ASD & LRFD - Superimposed Load, W (psf) 1390 1176 1006 869 756 663 586 520 463 2223 1881 1609 1390 1210 1062 937 831 741 - 2W PANELS 19 6'-0" 3W PANELS GA GENERAL INFORMATION 97 TABLE OF CONTENTS 3.3 2WH-36 Composite Deck 4" Total Slab Depth Light Weight Concrete (110 pcf) Gage 22 21 20 GA 22 Concrete Volume 0.907yd3/100ft2 Single 8' - 8" 9' - 10" 10' - 5" Maximum Unshored Span (in) Triple Gage 10' - 4" 19 11' - 4" 18 11' - 9" 16 Double 9' - 4" 10' - 9" 11' - 5" Vertical Load Span (in) 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 383 612 - 323 517 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 7'-0" ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 1575 1410 1397 1385 7'-6" 8'-0" 8'-6" 99 158 - 89 142 - 80 127 - 72 115 - 65 103 - Attachment Pattern 1566 1548 1531 1410 1399 1389 1397 1387 1378 1386 1377 1368 1516 1380 1370 1360 1502 1372 1362 1353 1489 1365 1355 1347 1485 1366 1357 1349 1474 1360 1351 1343 Mno/Ω= 22.8 kip-in/ft ϕMno= 34.9 kip-in/ft 430 688 - ASD & LRFD - Superimposed Load, W (psf) 363 310 267 232 203 179 159 141 581 496 428 372 325 287 254 226 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 1828 1800 1756 1719 1686 1657 1544 1537 1512 1491 1472 1456 1522 1517 1494 1474 1456 1441 1502 1499 1477 1458 1442 1427 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 453 724 - 382 612 - 9'-0" 36/4 1631 1442 1427 1414 7'-6" 8'-0" 8'-6" 9'-0" 126 201 - 113 180 - 100 162 100 88 146 88 78 132 78 69 119 69 Attachment Pattern 1622 1601 1581 1442 1430 1419 1428 1417 1406 1416 1405 1395 1564 1408 1396 1386 1548 1399 1388 1378 1533 1390 1380 1370 1530 1393 1383 1373 1517 1385 1375 1366 Mno/Ω= 25.5 kip-in/ft ϕMno= 39.0 kip-in/ft 36/4 1660 1458 1442 1429 Vn/Ω = 2.26 kip/ft ϕ Vn = 4.52 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 327 282 245 215 189 168 149 523 451 392 344 303 268 239 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 1869 1840 1793 1753 1718 1687 1566 1560 1533 1511 1491 1473 1542 1538 1513 1492 1473 1457 1523 1520 1496 1476 1458 1443 Vn/Ω = 2.26 kip/ft ϕ Vn = 4.10 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 34.1 in4/ft Iu = 64.0 in4/ft 7'-0" Triple 13' - 3" 13' - 6" 14' - 2" 111 177 - Icr = 31.2 in4/ft Iu = 62.4 in4/ft 7'-0" Double 12' - 9" 13' - 8" 15' - 1" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 6'-6" Concrete + Deck = 28.8 psf (Icr+Iu)/2 = 50.1 in4/ft 98 9'-0" 6'-0" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) 1748 1721 1684 1651 1623 1598 1500 1492 1471 1453 1437 1423 1481 1475 1455 1438 1422 1409 1463 1458 1439 1423 1409 1396 Concrete + Deck = 28.7 psf (Icr+Iu)/2 = 49 in4/ft 20 8'-0" ASD & LRFD - Superimposed Load, W (psf) 275 237 206 180 158 140 124 441 379 329 288 253 224 198 - Concrete + Deck = 28.5 psf (Icr+Iu)/2 = 46.8 in4/ft Vertical Load Span (in) 7'-6" Single 11' - 4" 11' - 7" 12' - 1" 133 213 - 116 191 116 102 172 102 90 155 90 79 140 79 70 127 70 Attachment Pattern 1651 1628 1607 1459 1446 1434 1444 1432 1420 1432 1420 1409 1588 1423 1410 1399 1571 1413 1401 1390 1555 1404 1392 1382 1553 1407 1396 1386 1539 1399 1388 1379 Icr = 35.5 in4/ft Iu = 64.7 in4/ft Composite and Non-Composite Deck Catalog • February 2016 Mno/Ω= 26.8 kip-in/ft ϕMno= 41.0 kip-in/ft Vn/Ω = 2.26 kip/ft ϕ Vn = 4.52 kip/ft www.ascsd.com TABLE OF CONTENTS 2WH-36 Composite Deck 2.3 4" Total Slab Depth Light Weight Concrete (110 pcf) Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-6" 532 851 - ASD & LRFD - Superimposed Load, W (psf) 450 385 333 290 254 224 193 166 720 616 532 463 407 359 318 284 193 166 7'-0" 18 143 254 143 125 229 125 109 206 109 96 187 96 85 169 85 75 154 75 Attachment Pattern 1755 1727 1701 1521 1504 1489 1504 1488 1473 1490 1475 1461 1678 1476 1461 1449 1656 1463 1449 1438 1637 1452 1438 1427 1636 1458 1445 1435 1619 1448 1435 1425 Mno/Ω= 31.3 kip-in/ft ϕMno= 47.9 kip-in/ft 6'-6" 585 936 - ASD & LRFD - Superimposed Load, W (psf) 495 424 367 320 281 237 202 173 793 679 587 511 449 397 352 314 237 202 173 7'-0" 7'-6" 8'-0" 8'-6" 6'-6" ASD, W/Ω LRFD, ϕW L/360 708 1133 - 600 960 - 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 150 282 150 130 254 130 114 229 114 100 208 100 89 189 89 79 172 79 Attachment Pattern 1833 1801 1771 1568 1549 1531 1548 1530 1514 1535 1517 1501 1745 1516 1499 1487 1720 1501 1485 1474 1698 1488 1473 1462 1699 1497 1482 1472 1679 1485 1471 1461 Mno/Ω= 34.3 kip-in/ft ϕMno= 52.5 kip-in/ft 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 514 445 370 308 260 221 189 822 712 621 546 483 430 385 370 308 260 221 189 36/4 2033 1671 1633 1632 164 346 164 142 312 142 124 282 124 110 256 110 97 233 97 86 213 86 Attachment Pattern 2032 1989 1951 1689 1664 1641 1653 1629 1608 1652 1628 1607 1915 1619 1588 1587 1883 1600 1570 1570 1854 1583 1554 1553 1860 1600 1572 1572 1834 1584 1557 1556 Mno/Ω= 41.2 kip-in/ft ϕMno= 63.1 kip-in/ft Icr = 49.5 in4/ft Iu = 73.0 in4/ft Vn/Ω = 2.26 kip/ft ϕ Vn = 4.52 kip/ft D PANEL LRFD - Diaphragm Shear, ϕSn (plf / ft) 2392 2362 2278 2204 2140 2083 1849 1862 1813 1770 1733 1700 1792 1809 1763 1724 1690 1660 1790 1807 1762 1723 1689 1659 Vn/Ω = 2.26 kip/ft ϕ Vn = 4.52 kip/ft C PANELS 6'-0" 36/4 1840 1560 1539 1525 Vn/Ω = 2.26 kip/ft ϕ Vn = 4.52 kip/ft N PANELS Vertical Load Span (in) 9'-0" Icr = 43.0 in4/ft Iu = 69.0 in4/ft Concrete + Deck = 30.1 psf (Icr+Iu)/2 = 61.3 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft 2620 2620 2620 6x6 W2.9xW2.9 As = 0.058 in2/ft 3970 3970 3970 6x6 W4.0xW4.0 As = 0.080 in2/ft 4960 4960 4960 4x4 W4xW4 As = 0.120 in2/ft 6760 6760 5170 4x4 W6xW6 As = 0.180 in2/ft 9460 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 36/4 1763 1516 1498 1483 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 6'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 2123 2091 2027 1971 1921 1878 PAF Base Steel ≥ .25" 1703 1704 1667 1635 1607 1582 PAF Base Steel ≥ 0.125" 1672 1675 1640 1610 1583 1560 #12 Screw Base Steel ≥ .0385" 1651 1656 1622 1593 1567 1545 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 9'-0" Icr = 40.1 in4/ft Iu = 67.3 in4/ft Concrete + Deck = 29.4 psf (Icr+Iu)/2 = 56 in4/ft 16 8'-6" B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2015 1984 1927 1878 1835 1797 1645 1642 1610 1582 1557 1535 1617 1617 1586 1559 1536 1516 1596 1597 1568 1543 1520 1501 Concrete + Deck = 29.2 psf (Icr+Iu)/2 = 53.7 in4/ft Vertical Load Span (in) 7'-6" 2W PANELS 19 6'-0" 3W PANELS GA Concrete Volume 0.907yd3/100ft2 GENERAL INFORMATION 99 TABLE OF CONTENTS 3.3 2WH-36 Composite Deck 4 1⁄2" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.061yd3/100ft2 1 Hour Fire Rating Gage 22 21 20 GA 22 Single 8' - 4" 9' - 5" 9' - 11" Maximum Unshored Span (in) Triple Gage 9' - 10" 19 10' - 10" 18 11' - 3" 16 Double 9' - 0" 10' - 4" 10' - 11" Vertical Load Span (in) 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 463 741 - 391 625 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 7'-0" ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 1899 1734 1721 1709 Icr = 42.7 in4/ft Iu = 87.7 in4/ft 7'-0" 7'-6" 8'-0" 8'-6" 120 192 - 108 173 - 97 155 - 88 140 - 79 127 - Attachment Pattern 1890 1872 1855 1734 1723 1713 1721 1711 1702 1710 1701 1692 1840 1705 1694 1684 1826 1697 1686 1677 1813 1689 1680 1671 1809 1691 1681 1673 1798 1684 1675 1667 Mno/Ω= 27.5 kip-in/ft ϕMno= 42.1 kip-in/ft 520 833 - 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 548 877 - 463 741 - 36/4 1955 1766 1751 1738 Icr = 46.8 in4/ft Iu = 89.8 in4/ft 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" Icr = 48.6 in4/ft Iu = 90.7 in4/ft 36/4 1984 1782 1766 1753 Vn/Ω = 2.63 kip/ft ϕ Vn = 4.38 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 153 245 - 137 220 - 123 198 - 111 178 - 101 161 - 91 146 - Attachment Pattern 1946 1925 1905 1766 1754 1743 1752 1741 1730 1740 1729 1719 1888 1732 1720 1710 1872 1723 1712 1702 1857 1715 1704 1694 1854 1717 1707 1697 1841 1709 1699 1690 Mno/Ω= 30.8 kip-in/ft ϕMno= 47.1 kip-in/ft Vn/Ω = 2.63 kip/ft ϕ Vn = 5.09 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 396 342 297 260 230 204 181 634 547 476 417 367 326 290 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2193 2164 2118 2077 2042 2011 1890 1884 1857 1835 1815 1797 1867 1862 1838 1816 1797 1781 1847 1844 1821 1800 1783 1767 Triple 12' - 8" 13' - 1" 13' - 9" 134 215 - ASD & LRFD - Superimposed Load, W (psf) 440 376 324 282 247 217 193 171 703 601 518 451 395 348 308 274 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2152 2124 2080 2043 2010 1981 1868 1861 1836 1815 1797 1780 1846 1841 1818 1798 1780 1765 1826 1823 1801 1782 1766 1751 9'-0" Double 12' - 3" 13' - 1" 14' - 7" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 6'-6" Concrete + Deck = 33.4 psf (Icr+Iu)/2 = 69.7 in4/ft 100 9'-0" 6'-0" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2072 2045 2008 1975 1947 1922 1824 1816 1795 1777 1761 1747 1805 1799 1779 1762 1746 1733 1787 1782 1763 1747 1733 1721 Concrete + Deck = 33.3 psf (Icr+Iu)/2 = 68.3 in4/ft 20 8'-0" ASD & LRFD - Superimposed Load, W (psf) 333 287 250 218 192 170 151 534 460 399 349 307 272 241 - Concrete + Deck = 33.1 psf (Icr+Iu)/2 = 65.2 in4/ft Vertical Load Span (in) 7'-6" Single 10' - 10" 11' - 2" 11' - 9" 162 259 - 145 233 - 131 210 - 118 189 - 107 171 - 97 155 - Attachment Pattern 1975 1952 1931 1783 1770 1758 1769 1756 1745 1756 1744 1733 1912 1747 1734 1723 1895 1737 1725 1714 1879 1728 1716 1706 1877 1731 1720 1710 1863 1723 1712 1703 Mno/Ω= 32.4 kip-in/ft ϕMno= 49.5 kip-in/ft Composite and Non-Composite Deck Catalog • February 2016 Vn/Ω = 2.63 kip/ft ϕ Vn = 5.26 kip/ft www.ascsd.com TABLE OF CONTENTS 2WH-36 Composite Deck 3.3 4 1⁄2" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.061yd3/100ft2 1 Hour Fire Rating Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-6" 645 1031 - ASD & LRFD - Superimposed Load, W (psf) 545 467 403 351 308 272 242 216 873 747 645 562 494 436 387 345 - 7'-0" 18 173 278 173 151 251 151 133 227 133 118 206 118 105 188 105 Attachment Pattern 2079 2051 2025 1845 1828 1813 1828 1812 1798 1814 1799 1785 2002 1800 1785 1773 1980 1787 1773 1762 1961 1776 1762 1751 1960 1782 1769 1759 1943 1772 1759 1749 Mno/Ω= 37.8 kip-in/ft ϕMno= 57.9 kip-in/ft 6'-6" 710 1135 - ASD & LRFD - Superimposed Load, W (psf) 601 515 445 388 341 301 268 239 961 823 712 621 545 482 428 383 - 7'-0" 7'-6" 8'-0" 8'-6" 6'-0" 9'-0" 36/4 2164 1884 1863 1849 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 208 343 208 181 309 181 158 279 158 139 253 139 123 230 123 109 210 109 Attachment Pattern 2157 2125 2095 1892 1873 1855 1872 1854 1838 1859 1841 1826 2069 1840 1823 1811 2044 1825 1809 1798 2022 1812 1797 1786 2023 1821 1806 1796 2003 1809 1795 1785 Mno/Ω= 41.5 kip-in/ft ϕMno= 63.5 kip-in/ft 197 380 197 172 344 172 152 313 152 134 285 134 119 260 119 Attachment Pattern 2356 2313 2275 2013 1988 1965 1977 1953 1932 1976 1952 1931 2239 1944 1912 1911 2207 1924 1894 1894 2178 1907 1878 1877 2184 1924 1896 1896 2158 1908 1881 1880 Mno/Ω= 50.0 kip-in/ft ϕMno= 76.5 kip-in/ft Icr = 68.0 in4/ft Iu = 101.8 in4/ft Vn/Ω = 2.63 kip/ft ϕ Vn = 5.26 kip/ft D PANEL 227 421 227 C PANELS 36/4 2357 1995 1957 1956 Vn/Ω = 2.63 kip/ft ϕ Vn = 5.26 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 859 728 624 541 472 415 360 306 262 1375 1165 999 865 755 664 588 523 468 360 306 262 LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 2716 2686 2602 2528 2464 2408 PAF Base Steel ≥ .25" 2173 2186 2137 2094 2057 2025 PAF Base Steel ≥ 0.125" 2116 2133 2087 2048 2014 1984 #12 Screw Base Steel ≥ .0385" 2114 2131 2086 2047 2013 1983 Vn/Ω = 2.63 kip/ft ϕ Vn = 5.26 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 59.0 in4/ft Iu = 96.5 in4/ft Concrete + Deck = 34.6 psf (Icr+Iu)/2 = 84.9 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft 2990 2990 2990 6x6 W2.9xW2.9 As = 0.058 in2/ft 4340 4340 4340 6x6 W4.0xW4.0 As = 0.080 in2/ft 5330 5330 5170 4x4 W4xW4 As = 0.120 in2/ft 7130 7130 5170 4x4 W6xW6 As = 0.180 in2/ft 9830 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 193 309 - N PANELS ASD, W/Ω LRFD, ϕW L/360 36/4 2087 1840 1822 1807 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 6'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 2447 2415 2351 2295 2245 2202 PAF Base Steel ≥ .25" 2027 2028 1991 1959 1931 1906 PAF Base Steel ≥ 0.125" 1996 2000 1964 1934 1908 1884 #12 Screw Base Steel ≥ .0385" 1975 1980 1946 1917 1891 1869 Vertical Load Span (in) 9'-0" Icr = 55.0 in4/ft Iu = 94.2 in4/ft Concrete + Deck = 34.0 psf (Icr+Iu)/2 = 77.8 in4/ft 16 8'-6" B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2339 2308 2251 2202 2159 2121 1969 1966 1934 1906 1881 1859 1941 1941 1910 1884 1860 1840 1920 1921 1892 1867 1844 1825 Concrete + Deck = 33.8 psf (Icr+Iu)/2 = 74.6 in4/ft Vertical Load Span (in) 7'-6" 2W PANELS 19 6'-0" 3W PANELS GA GENERAL INFORMATION 101 TABLE OF CONTENTS 3.3 2WH-36 Composite Deck 5" Total Slab Depth Light Weight Concrete (110 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.125yd3/100ft2 Single 8' - 0" 9' - 0" 9' - 6" Maximum Unshored Span (in) Triple Gage 9' - 5" 19 10' - 5" 18 10' - 10" 16 Double 8' - 9" 10' - 0" 10' - 6" Vertical Load Span (in) 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 548 876 - 462 740 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 7'-0" ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 2223 2058 2045 2033 Icr = 56.6 in4/ft Iu = 119.3 in4/ft 7'-0" 7'-6" 8'-0" 8'-6" 143 229 - 128 206 - 116 185 - 104 167 - 94 151 - Attachment Pattern 2214 2196 2179 2058 2047 2037 2045 2035 2026 2034 2025 2016 2164 2029 2018 2008 2150 2021 2011 2001 2137 2013 2004 1995 2133 2015 2005 1997 2122 2008 1999 1991 Mno/Ω= 32.5 kip-in/ft ϕMno= 49.8 kip-in/ft 616 985 - 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 649 1038 - 549 878 - 36/4 2279 2090 2075 2062 Icr = 62.0 in4/ft Iu = 122.0 in4/ft 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" Icr = 64.5 in4/ft Iu = 123.2 in4/ft 36/4 2308 2106 2090 2077 Vn/Ω = 3.02 kip/ft ϕ Vn = 4.67 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 182 291 - 163 261 - 147 235 - 133 212 - 120 192 - 109 174 - Attachment Pattern 2270 2249 2229 2090 2078 2067 2077 2065 2054 2064 2053 2043 2212 2056 2045 2034 2196 2047 2036 2026 2181 2039 2028 2018 2178 2041 2031 2021 2165 2034 2023 2015 Mno/Ω= 36.4 kip-in/ft ϕMno= 55.7 kip-in/ft Vn/Ω = 3.02 kip/ft ϕ Vn = 5.38 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 469 405 353 309 273 242 215 751 648 564 494 436 387 345 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2517 2488 2442 2402 2366 2336 2214 2208 2181 2159 2139 2121 2191 2186 2162 2140 2121 2105 2171 2168 2145 2124 2107 2091 Triple 12' - 2" 12' - 8" 13' - 4" 160 256 - ASD & LRFD - Superimposed Load, W (psf) 521 445 384 334 293 258 229 204 833 712 614 534 468 413 366 326 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2476 2448 2404 2367 2334 2305 2192 2185 2160 2139 2121 2104 2170 2165 2142 2122 2104 2089 2151 2147 2125 2106 2090 2075 9'-0" Double 11' - 9" 12' - 7" 14' - 2" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 6'-6" Concrete + Deck = 38.0 psf (Icr+Iu)/2 = 93.9 in4/ft 102 9'-0" 6'-0" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2396 2369 2332 2299 2271 2246 2148 2141 2119 2101 2085 2071 2129 2123 2103 2086 2071 2057 2111 2106 2087 2071 2057 2045 Concrete + Deck = 37.9 psf (Icr+Iu)/2 = 92 in4/ft 20 8'-0" ASD & LRFD - Superimposed Load, W (psf) 395 340 296 259 228 201 179 632 544 473 414 364 322 286 - Concrete + Deck = 37.7 psf (Icr+Iu)/2 = 87.9 in4/ft Vertical Load Span (in) 7'-6" Single 10' - 5" 10' - 8" 11' - 5" 193 308 - 173 277 - 156 249 - 141 225 - 128 204 - 116 185 - Attachment Pattern 2299 2276 2255 2107 2094 2082 2093 2080 2069 2080 2068 2057 2236 2071 2058 2047 2219 2061 2049 2038 2203 2052 2040 2030 2201 2055 2044 2034 2187 2047 2036 2027 Mno/Ω= 38.3 kip-in/ft ϕMno= 58.5 kip-in/ft Composite and Non-Composite Deck Catalog • February 2016 Vn/Ω = 3.02 kip/ft ϕ Vn = 5.77 kip/ft www.ascsd.com TABLE OF CONTENTS 2WH-36 Composite Deck 3.3 5" Total Slab Depth Light Weight Concrete (110 pcf) Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-6" 7'-0" 18 6'-0" 6'-6" 7'-0" 187 299 - 169 271 - 154 246 - 140 224 - Attachment Pattern 2403 2375 2349 2169 2152 2137 2152 2136 2122 2138 2123 2110 2326 2124 2109 2097 2305 2111 2097 2086 2285 2100 2086 2075 2284 2106 2093 2083 2267 2096 2083 2073 Mno/Ω= 44.8 kip-in/ft ϕMno= 68.5 kip-in/ft 7'-6" 8'-0" 8'-6" 9'-0" 6'-0" 36/4 2488 2208 2187 2173 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 255 409 - 230 368 - 208 333 - 187 302 187 165 275 165 147 250 147 Attachment Pattern 2481 2449 2419 2216 2197 2179 2197 2178 2162 2183 2165 2150 2393 2164 2147 2135 2368 2149 2133 2122 2346 2136 2121 2110 2347 2145 2130 2120 2327 2133 2119 2109 Mno/Ω= 49.2 kip-in/ft ϕMno= 75.2 kip-in/ft 304 502 304 265 453 265 232 411 232 204 373 204 180 340 180 160 311 160 Attachment Pattern 2680 2637 2599 2337 2312 2289 2301 2277 2256 2300 2277 2255 2564 2268 2236 2235 2531 2248 2218 2218 2502 2231 2202 2201 2508 2248 2220 2220 2482 2232 2205 2204 Mno/Ω= 59.3 kip-in/ft ϕMno= 90.8 kip-in/ft Icr = 90.5 in4/ft Iu = 137.6 in4/ft Vn/Ω = 3.02 kip/ft ϕ Vn = 6.04 kip/ft D PANEL 36/4 2681 2319 2281 2280 Vn/Ω = 3.02 kip/ft ϕ Vn = 6.04 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1007 866 743 643 562 494 438 390 349 1634 1386 1188 1029 899 791 700 624 558 LRFD - Diaphragm Shear, ϕSn (plf / ft) 3040 3010 2926 2852 2788 2732 2497 2510 2461 2418 2381 2349 2440 2457 2412 2372 2338 2308 2438 2455 2410 2371 2337 2307 Vn/Ω = 3.02 kip/ft ϕ Vn = 6.04 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 78.5 in4/ft Iu = 130.7 in4/ft Concrete + Deck = 39.2 psf (Icr+Iu)/2 = 114 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft 3360 3360 3360 6x6 W2.9xW2.9 As = 0.058 in2/ft 4710 4710 4710 6x6 W4.0xW4.0 As = 0.080 in2/ft 5700 5700 5170 4x4 W4xW4 As = 0.120 in2/ft 7500 7500 5170 4x4 W6xW6 As = 0.180 in2/ft 10200 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 207 331 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 2411 2164 2146 2132 230 368 - N PANELS ASD, W/Ω LRFD, ϕW L/360 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 842 713 611 528 461 405 358 318 285 1347 1141 977 845 737 648 573 509 455 - LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 2771 2740 2675 2619 2570 2526 PAF Base Steel ≥ .25" 2351 2352 2315 2283 2255 2230 PAF Base Steel ≥ 0.125" 2320 2324 2289 2258 2232 2208 #12 Screw Base Steel ≥ .0385" 2299 2304 2270 2241 2215 2193 Vertical Load Span (in) 9'-0" Icr = 73.0 in4/ft Iu = 127.7 in4/ft Concrete + Deck = 38.6 psf (Icr+Iu)/2 = 105 in4/ft 16 8'-6" B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2663 2632 2575 2526 2483 2445 2293 2290 2258 2230 2205 2183 2265 2265 2234 2208 2184 2164 2244 2245 2216 2191 2168 2149 Concrete + Deck = 38.3 psf (Icr+Iu)/2 = 100 in4/ft Vertical Load Span (in) 7'-6" ASD & LRFD - Superimposed Load, W (psf) 764 647 554 479 417 366 324 288 257 1223 1035 886 766 668 586 518 460 411 - 2W PANELS 19 6'-0" 3W PANELS GA Concrete Volume 1.125yd3/100ft2 GENERAL INFORMATION 103 TABLE OF CONTENTS 3.3 2WH-36 Composite Deck 5 1⁄4" Total Slab Depth Light Weight Concrete (110 pcf) Gage 22 21 20 GA 22 Concrete Volume 1.392yd3/100ft2 2 Hour Fire Rating Single 7' - 10" 8' - 10" 9' - 4" Maximum Unshored Span (in) Triple Gage 9' - 3" 19 10' - 3" 18 10' - 8" 16 Double 8' - 7" 9' - 10" 10' - 4" Vertical Load Span (in) 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 591 946 - 499 799 - Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 7'-0" ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 2385 2220 2207 2195 Icr = 64.4 in4/ft Iu = 137.7 in4/ft 7'-0" 7'-6" 8'-0" 8'-6" 155 248 - 139 223 - 125 201 - 113 181 - 102 164 - Attachment Pattern 2376 2358 2341 2220 2209 2199 2207 2197 2188 2196 2187 2178 2326 2191 2180 2170 2312 2183 2173 2163 2299 2175 2166 2157 2295 2177 2167 2159 2284 2170 2161 2153 Mno/Ω= 35.1 kip-in/ft ϕMno= 53.7 kip-in/ft 665 1064 - 6'-0" 6'-6" ASD, W/Ω LRFD, ϕW L/360 701 1122 - 593 949 - 36/4 2441 2252 2237 2224 Icr = 70.6 in4/ft Iu = 140.7 in4/ft 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" Icr = 73.5 in4/ft Iu = 142.2 in4/ft 36/4 2470 2268 2252 2239 Vn/Ω = 3.22 kip/ft ϕ Vn = 4.82 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 197 315 - 177 283 - 159 255 - 144 230 - 130 208 - 118 189 - Attachment Pattern 2432 2411 2391 2252 2240 2229 2239 2227 2216 2226 2215 2205 2374 2218 2207 2196 2358 2209 2198 2188 2343 2201 2190 2180 2340 2203 2193 2183 2327 2196 2185 2177 Mno/Ω= 39.3 kip-in/ft ϕMno= 60.1 kip-in/ft Vn/Ω = 3.22 kip/ft ϕ Vn = 5.53 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 507 438 381 334 295 261 233 811 700 610 535 472 418 373 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2679 2650 2604 2564 2528 2498 2376 2370 2343 2321 2301 2283 2353 2348 2324 2302 2283 2267 2333 2330 2307 2286 2269 2253 Triple 11' - 11" 12' - 6" 13' - 2" 173 277 - ASD & LRFD - Superimposed Load, W (psf) 562 481 415 361 316 279 247 220 900 769 664 578 506 446 396 352 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 2638 2610 2566 2529 2496 2467 2354 2347 2322 2301 2283 2266 2332 2327 2304 2284 2266 2251 2313 2309 2287 2268 2252 2237 9'-0" Double 11' - 7" 12' - 5" 14' - 0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 6'-6" Concrete + Deck = 40.3 psf (Icr+Iu)/2 = 108 in4/ft 104 9'-0" 6'-0" Vertical Load Span (in) Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2558 2531 2494 2461 2433 2408 2310 2303 2281 2263 2247 2233 2291 2285 2265 2248 2233 2219 2273 2268 2249 2233 2219 2207 Concrete + Deck = 40.2 psf (Icr+Iu)/2 = 106 in4/ft 20 8'-0" ASD & LRFD - Superimposed Load, W (psf) 426 368 319 280 246 218 194 682 588 511 447 394 348 310 - Concrete + Deck = 40.0 psf (Icr+Iu)/2 = 101 in4/ft Vertical Load Span (in) 7'-6" Single 10' - 3" 10' - 6" 11' - 3" 209 334 - 187 300 - 169 270 - 153 244 - 138 221 - 126 201 - Attachment Pattern 2461 2438 2417 2269 2256 2244 2255 2242 2231 2242 2230 2219 2398 2233 2220 2209 2381 2223 2211 2200 2365 2214 2202 2192 2363 2217 2206 2196 2349 2209 2198 2189 Mno/Ω= 41.3 kip-in/ft ϕMno= 63.2 kip-in/ft Composite and Non-Composite Deck Catalog • February 2016 Vn/Ω = 3.22 kip/ft ϕ Vn = 5.92 kip/ft www.ascsd.com TABLE OF CONTENTS 2WH-36 Composite Deck 3.3 5 1⁄4" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.292yd3/100ft2 2 Hour Fire Rating Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-6" 7'-0" 18 6'-0" 6'-6" 7'-0" 203 324 - 184 294 - 167 267 - 152 243 - Attachment Pattern 2565 2537 2511 2331 2314 2299 2314 2298 2284 2300 2285 2272 2488 2286 2271 2259 2467 2273 2259 2248 2447 2262 2248 2237 2446 2268 2255 2245 2429 2258 2245 2235 Mno/Ω= 48.4 kip-in/ft ϕMno= 74.0 kip-in/ft 7'-6" 8'-0" 8'-6" 9'-0" 6'-0" 36/4 2650 2370 2349 2335 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 277 443 - 249 399 - 225 361 - 205 327 - 186 298 - 169 272 169 Attachment Pattern 2643 2611 2581 2378 2359 2341 2359 2340 2324 2345 2327 2312 2555 2326 2309 2297 2530 2311 2295 2284 2508 2298 2283 2272 2509 2307 2292 2282 2489 2295 2281 2271 Mno/Ω= 53.1 kip-in/ft ϕMno= 81.3 kip-in/ft 340 544 - 304 491 304 266 445 266 234 405 234 207 369 207 184 338 184 Attachment Pattern 2842 2799 2761 2499 2474 2451 2463 2439 2418 2462 2439 2417 2726 2430 2398 2397 2693 2410 2380 2380 2664 2393 2364 2363 2670 2410 2382 2382 2644 2394 2367 2366 Mno/Ω= 64.2 kip-in/ft ϕMno= 98.2 kip-in/ft Icr = 103.3 in4/ft Iu = 158.4 in4/ft Vn/Ω = 3.22 kip/ft ϕ Vn = 6.44 kip/ft D PANEL 36/4 2843 2482 2443 2442 Vn/Ω = 3.22 kip/ft ϕ Vn = 6.44 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1074 937 804 696 608 535 474 422 378 1769 1500 1286 1114 973 856 758 676 605 LRFD - Diaphragm Shear, ϕSn (plf / ft) 3202 3173 3088 3014 2950 2894 2659 2672 2623 2580 2543 2511 2602 2619 2574 2534 2500 2470 2600 2617 2572 2533 2499 2469 Vn/Ω = 3.22 kip/ft ϕ Vn = 6.44 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 89.5 in4/ft Iu = 150.6 in4/ft Concrete + Deck = 41.5 psf (Icr+Iu)/2 = 131 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft 3550 3550 3550 6x6 W2.9xW2.9 As = 0.058 in2/ft 4900 4900 4900 6x6 W4.0xW4.0 As = 0.080 in2/ft 5890 5890 5170 4x4 W4xW4 As = 0.120 in2/ft 7690 7690 5170 4x4 W6xW6 As = 0.180 in2/ft 10390 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 224 359 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 2573 2326 2308 2294 249 399 - N PANELS ASD, W/Ω LRFD, ϕW L/360 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 910 771 661 572 499 438 388 345 308 1457 1234 1057 915 798 701 620 552 493 - LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 2933 2902 2837 2781 2732 2688 PAF Base Steel ≥ .25" 2513 2514 2477 2445 2417 2392 PAF Base Steel ≥ 0.125" 2482 2486 2451 2420 2394 2370 #12 Screw Base Steel ≥ .0385" 2461 2466 2432 2403 2377 2355 Vertical Load Span (in) 9'-0" Icr = 83.2 in4/ft Iu = 147.2 in4/ft Concrete + Deck = 40.9 psf (Icr+Iu)/2 = 120 in4/ft 16 8'-6" B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 2825 2794 2737 2688 2645 2607 2455 2452 2420 2392 2367 2345 2427 2427 2396 2370 2346 2326 2406 2407 2378 2353 2331 2311 Concrete + Deck = 40.6 psf (Icr+Iu)/2 = 115 in4/ft Vertical Load Span (in) 7'-6" ASD & LRFD - Superimposed Load, W (psf) 826 699 599 518 451 396 350 311 278 1321 1119 958 828 722 634 560 498 445 - 2W PANELS 19 6'-0" 3W PANELS GA GENERAL INFORMATION 105 TABLE OF CONTENTS 3.3 2WH-36 Composite Deck 6 3⁄16" Total Slab Depth Light Weight Concrete (110 pcf) Gage 22 21 20 GA Concrete Volume 1.582yd3/100ft2 3 Hour Fire Rating Single 7' - 4" 8' - 3" 8' - 9" Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 22 Maximum Unshored Span (in) Triple Gage 8' - 8" 19 9' - 7" 18 10' - 0" 16 Double 8' - 2" 9' - 3" 9' - 8" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-0" 6'-6" 760 642 1216 1028 - 7'-0" ASD, W/Ω LRFD, ϕW L/360 21 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" ASD, W/Ω LRFD, ϕW L/360 20 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-0" 6'-6" 9'-0" 36/4 2993 2828 2815 2803 Icr = 99.2 in4/ft Iu = 224.0 in4/ft 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3246 3217 3174 3137 3104 3075 2961 2955 2930 2909 2890 2874 2939 2934 2911 2891 2874 2858 2920 2917 2895 2876 2859 2845 6'-0" 6'-6" 36/4 3049 2859 2845 2832 Icr = 108.8 in4/ft Iu = 228.5 in4/ft 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" Icr = 113.4 in4/ft Iu = 230.7 in4/ft 36/4 3078 2875 2860 2847 Triple 11' - 2" 11' - 11" 12' - 7" 224 358 - 201 321 - 180 289 - 163 260 - 147 235 - 133 213 - Attachment Pattern 2984 2965 2949 2827 2817 2807 2815 2805 2796 2804 2794 2786 2933 2798 2788 2778 2919 2790 2780 2771 2907 2783 2773 2764 2903 2784 2775 2766 2892 2778 2769 2760 Mno/Ω= 45.0 kip-in/ft ϕMno= 68.8 kip-in/ft Vn/Ω = 3.78 kip/ft ϕ Vn = 5.42 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 255 408 - 229 367 - 207 330 - 187 299 - 169 271 - 154 246 - Attachment Pattern 3040 3018 2999 2860 2848 2836 2846 2834 2824 2834 2823 2813 2981 2826 2814 2804 2965 2817 2805 2795 2951 2808 2797 2788 2947 2811 2800 2791 2935 2803 2793 2784 Mno/Ω= 50.4 kip-in/ft ϕMno= 77.2 kip-in/ft Vn/Ω = 4.02 kip/ft ϕ Vn = 6.13 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 903 764 654 565 492 432 381 338 302 1445 1223 1046 904 787 691 610 541 483 LRFD - Diaphragm Shear, ϕSn (plf / ft) 3287 3257 3211 3171 3136 3105 2983 2977 2951 2928 2908 2891 2960 2956 2931 2910 2891 2875 2940 2938 2914 2894 2876 2861 Double 10' - 10" 11' - 7" 13' - 4" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 856 724 619 535 466 408 360 320 285 1370 1159 991 856 745 653 576 511 456 - Concrete + Deck = 48.9 psf (Icr+Iu)/2 = 172 in4/ft 106 8'-6" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3166 3139 3101 3069 3040 3015 2918 2910 2889 2871 2855 2840 2899 2892 2872 2855 2840 2827 2881 2876 2857 2841 2827 2814 Concrete + Deck = 48.8 psf (Icr+Iu)/2 = 169 in4/ft Vertical Load Span (in) 8'-0" ASD & LRFD - Superimposed Load, W (psf) 549 473 412 361 318 281 250 878 758 659 577 508 450 401 - Concrete + Deck = 48.6 psf (Icr+Iu)/2 = 162 in4/ft Vertical Load Span (in) 7'-6" Single 9' - 7" 9' - 11" 10' - 7" 270 432 - 243 389 - 219 351 - 198 317 - 180 288 - 164 262 - Attachment Pattern 3069 3046 3025 2877 2864 2851 2862 2850 2838 2850 2838 2827 3006 2840 2828 2817 2989 2830 2818 2808 2973 2821 2810 2800 2970 2825 2814 2804 2956 2816 2806 2797 Mno/Ω= 53.1 kip-in/ft ϕMno= 81.2 kip-in/ft Composite and Non-Composite Deck Catalog • February 2016 Vn/Ω = 4.02 kip/ft ϕ Vn = 6.52 kip/ft www.ascsd.com TABLE OF CONTENTS 2WH-36 Composite Deck 3.3 6 3⁄16" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.582yd3/100ft2 3 Hour Fire Rating Vertical Load Span (in) ASD, W/Ω LRFD, ϕW L/360 Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 6'-6" 7'-0" 18 6'-0" 6'-6" 7'-0" 263 422 - 239 382 - 217 348 - 198 317 - Attachment Pattern 3173 3144 3119 2939 2922 2907 2921 2905 2891 2908 2893 2879 3095 2893 2878 2867 3074 2881 2866 2855 3055 2869 2856 2845 3054 2876 2862 2852 3036 2865 2853 2843 Mno/Ω= 62.3 kip-in/ft ϕMno= 95.3 kip-in/ft 7'-6" 8'-0" 8'-6" 9'-0" 6'-0" 36/4 3257 2977 2957 2943 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 359 575 - 324 519 - 293 470 - 266 426 - 243 388 - 222 355 - Attachment Pattern 3251 3218 3189 2986 2966 2949 2966 2948 2932 2953 2935 2919 3162 2933 2917 2905 3138 2919 2903 2892 3116 2906 2890 2880 3116 2915 2900 2890 3097 2903 2889 2879 Mno/Ω= 68.6 kip-in/ft ϕMno= 104.9 kip-in/ft 443 709 - 400 641 - 363 581 - 330 529 - 302 483 - 276 442 - Attachment Pattern 3450 3407 3368 3107 3081 3058 3071 3047 3025 3070 3046 3025 3333 3037 3006 3005 3301 3018 2988 2987 3272 3000 2972 2971 3278 3018 2990 2989 3252 3001 2975 2974 Mno/Ω= 83.1 kip-in/ft ϕMno= 127.2 kip-in/ft Icr = 161.0 in4/ft Iu = 255.5 in4/ft Vn/Ω = 4.02 kip/ft ϕ Vn = 8.04 kip/ft D PANEL 36/4 3451 3089 3051 3050 Vn/Ω = 4.02 kip/ft ϕ Vn = 8.04 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1341 1217 1044 905 790 696 617 550 492 2295 1947 1670 1447 1265 1113 987 879 788 LRFD - Diaphragm Shear, ϕSn (plf / ft) 3809 3780 3695 3622 3558 3501 3267 3279 3230 3188 3151 3118 3209 3226 3181 3142 3108 3078 3208 3225 3180 3141 3107 3077 Vn/Ω = 4.02 kip/ft ϕ Vn = 7.59 kip/ft 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" Icr = 138.9 in4/ft Iu = 243.6 in4/ft Concrete + Deck = 50.1 psf (Icr+Iu)/2 = 208 in4/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 3/4" Welded Shear Studs 12 in o.c. 24 in o.c. 36 in o.c. www.ascsd.com 6x6 W1.4xW1.4 As = 0.028 in2/ft n/a n/a n/a 6x6 W2.9xW2.9 As = 0.058 in2/ft 5590 5590 5170 6x6 W4.0xW4.0 As = 0.080 in2/ft 6580 6580 5170 4x4 W4xW4 As = 0.120 in2/ft 8380 7750 5170 4x4 W6xW6 As = 0.180 in2/ft 11080 7750 5170 Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® All Gages 291 466 - C PANELS Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" 36/4 3181 2934 2915 2901 323 517 - N PANELS ASD, W/Ω LRFD, ϕW L/360 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" ASD & LRFD - Superimposed Load, W (psf) 1177 998 855 740 646 568 503 447 400 1884 1596 1368 1184 1034 909 804 716 640 - LRFD - Diaphragm Shear, ϕSn (plf / ft) Arc Spot Weld 1/2" Effective Dia 3541 3509 3444 3388 3339 3296 PAF Base Steel ≥ .25" 3121 3122 3084 3052 3024 2999 PAF Base Steel ≥ 0.125" 3090 3093 3058 3028 3001 2978 #12 Screw Base Steel ≥ .0385" 3068 3073 3040 3011 2985 2963 Vertical Load Span (in) 9'-0" Icr = 128.9 in4/ft Iu = 238.4 in4/ft Concrete + Deck = 49.5 psf (Icr+Iu)/2 = 191 in4/ft 16 8'-6" B PANELS ASD, W/Ω LRFD, ϕW L/360 8'-0" LRFD - Diaphragm Shear, ϕSn (plf / ft) 3433 3402 3345 3296 3253 3215 3062 3060 3027 2999 2975 2953 3035 3034 3004 2977 2954 2933 3014 3015 2986 2960 2938 2919 Concrete + Deck = 49.2 psf (Icr+Iu)/2 = 184 in4/ft Vertical Load Span (in) 7'-6" ASD & LRFD - Superimposed Load, W (psf) 1066 903 774 669 584 513 453 403 360 1706 1445 1238 1071 934 821 726 645 576 - 2W PANELS 19 6'-0" 3W PANELS GA GENERAL INFORMATION 107 TABLE OF CONTENTS 4.1 BH-36 2-3/8” 3-5/8” 6” 1-3/4” 1-1/2” 2-3/8” 3-5/8” 6” 1-1/2” 1-3/4” 1-3/4” 36” 36” BH-36 Profile BHN-36 Profile 36/4 Attachment Pattern B Series Embossment Panel Properties Gage Weight 22 20 18 16 w psf 1.75 2.09 2.76 3.43 Compression Gage Area 22 20 18 16 Ae in2/ft 0.179 0.235 0.351 0.330 Base Metal Thickness Yield Strength t in 0.0299 0.0359 0.0478 0.0598 Tensile Strength Area Fu ksi 65 65 65 65 Ag in2/ft 0.514 0.615 0.814 1.012 Fy ksi 50 50 50 50 Effective Section Modulus at Fy Bending Distance to Section N.A. from Section Modulus Bottom Modulus Se+ yb Sein3/ft in in3/ft 0.175 0.74 0.187 0.228 0.77 0.236 0.311 0.84 0.329 0.392 0.89 0.404 Gage 22 20 18 16 108 Condition 1" End 772 Interior 1229 End 1081 Interior 1737 End 1834 Interior 2984 End 2771 Interior 4555 Web Crippling Constraints 960 1482 1336 2078 2239 3525 3351 5329 1223 1832 1690 2551 2802 4276 4158 6405 h=1.32" Ig in4/ft 0.200 0.240 0.313 0.383 yb in 0.94 0.94 0.95 0.95 Sg in3/ft 0.213 0.253 0.330 0.404 Radius of Gyration r in 0.625 0.623 0.619 0.615 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 0.98 0.96 0.94 0.95 Reactions at Supports (plf) Based on Web Crippling Allowable (Rn/Ω) 2" 4" Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Moment of Inertia Moment of Inertia Ie+ in4/ft 0.157 0.197 0.287 0.377 I ein4/ft 0.197 0.237 0.313 0.383 Bearing Length of Webs 6" 1" 1223 1832 1690 2551 2802 4276 4158 6405 1180 1828 1655 2584 2805 4439 4240 6776 r=0.125" Composite and Non-Composite Deck Catalog • February 2016 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 0.171 0.211 0.296 0.379 Factored (ΦRn) 2" 4" 1469 2204 2045 3091 3425 5243 5127 7927 1871 2726 2586 3794 4287 6361 6361 9527 Iin4/ft 0.198 0.238 0.313 0.383 6" 1871 2726 2586 3794 4287 6361 6361 9527 θ=78.3º www.ascsd.com TABLE OF CONTENTS 2-3/8” 3-5/8” 6” 1-1/2” 36/7 GENERAL INFORMATION BHF-36 4.2 1-3/4” 36/4 Attachment Pattern 36” BHF-36 Profile Gage Gage Area Ag in2/ft 1.040 1.179 1.330 1.231 1.370 1.521 1.423 1.562 1.713 Effective Section Modulus at Fy Bending Distance to N.A. from Bottom yb in 0.43 0.39 0.35 0.53 0.48 0.44 0.61 0.56 0.52 Section Modulus Sein3/ft 0.438 0.452 0.465 0.569 0.587 0.604 0.698 0.719 0.739 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 0.73 0.66 0.58 0.77 0.71 0.65 0.81 0.75 0.70 Moment of Inertia Ie + in4/ft 0.354 0.381 0.404 0.489 0.529 0.566 0.619 0.673 0.724 Moment of Inertia I ein4/ft 0.389 0.445 0.505 0.486 0.547 0.617 0.582 0.646 0.723 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 0.389 0.420 0.448 0.514 0.558 0.598 0.633 0.689 0.742 Iin4/ft 0.413 0.463 0.515 0.512 0.569 0.631 0.609 0.671 0.741 C PANELS Section Modulus Se+ in3/ft 0.272 0.278 0.284 0.409 0.419 0.427 0.564 0.577 0.588 Radius of Gyration r in 0.665 0.651 0.634 0.677 0.670 0.659 0.682 0.679 0.674 N PANELS 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Area Ae in2/ft 0.643 0.744 0.861 0.876 0.977 1.094 1.105 1.206 1.323 Tensile Strength Fu ksi 65 65 65 65 65 65 65 65 65 B PANELS Compression Base Metal Thickness Yield Strength t Fy in ksi 0.0359 / 0.036 50 0.0359 / 0.047 50 0.0359 / 0.059 50 0.0478 / 0.036 50 0.0478 / 0.047 50 0.0478 / 0.059 50 0.0598 / 0.036 50 0.0598 / 0.047 50 0.0598 / 0.059 50 2W PANELS 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Weight w psf 3.69 4.16 4.68 4.35 4.83 5.35 5.03 5.51 6.03 Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Ig yb Sg in4/ft in in3/ft 0.460 0.58 0.462 0.499 0.52 0.471 0.535 0.48 0.479 0.564 0.65 0.601 0.614 0.59 0.613 0.661 0.55 0.624 0.661 0.70 0.736 0.721 0.65 0.752 0.777 0.60 0.767 3W PANELS Panel Properties D PANEL ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 109 TABLE OF CONTENTS 4.3 BHF-36 Cellular Composite Deck Normal Weight Concrete (145 pcf) Maximum Unshored Spans BHF-36 Cellular Shoring Table Total Slab Depth (in) Volume cy/100sf 3 1/2 0.776 4 1/2 1.085 5 1 Hour Fire Rating 1.239 6 2 Hour Fire Rating 1.548 6 3/4 3 Hour Fire Rating 1.780 Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 145 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 34.0 8' - 5" 10' - 9" 34.5 8' - 7" 10' - 11" 35.0 8' - 8" 11' - 0" 34.7 10' - 5" 12' - 5" 35.2 10' - 8" 13' - 3" 35.7 10' - 11" 13' - 5" 35.4 11' - 1" 13' - 3" 35.8 11' - 4" 13' - 11" 36.3 11' - 6" 14' - 1" 46.1 7' - 7" 9' - 9" 46.6 7' - 9" 9' - 11" 47.1 7' - 10" 10' - 0" 46.8 9' - 6" 11' - 3" 47.2 9' - 9" 12' - 1" 47.8 9' - 11" 12' - 2" 47.4 10' - 1" 12' - 0" 47.9 10' - 5" 13' - 0" 48.4 10' - 7" 13' - 2" 52.1 7' - 3" 9' - 5" 52.6 7' - 5" 9' - 6" 53.1 7' - 6" 9' - 7" 52.8 9' - 1" 10' - 10" 53.3 9' - 4" 11' - 7" 53.8 9' - 7" 11' - 8" 53.5 9' - 9" 11' - 6" 54.0 10' - 0" 12' - 8" 54.5 10' - 3" 12' - 10" 64.2 6' - 9" 8' - 9" 64.7 6' - 10" 8' - 10" 65.2 6' - 11" 8' - 11" 64.9 8' - 7" 10' - 0" 65.4 8' - 9" 10' - 9" 65.9 8' - 10" 10' - 10" 65.6 9' - 2" 10' - 9" 66.0 9' - 5" 11' - 11" 66.6 9' - 7" 12' - 2" 73.3 6' - 5" 8' - 4" 73.8 6' - 6" 8' - 5" 74.3 6' - 8" 8' - 6" 73.9 8' - 2" 9' - 7" 74.4 8' - 4" 10' - 3" 74.9 8' - 5" 10' - 4" 74.6 8' - 9" 10' - 3" 75.1 9' - 0" 11' - 5" 75.6 9' - 3" 11' - 9" Triple 9' - 9" 9' - 10" 10' - 0" 11' - 11" 12' - 0" 12' - 2" 12' - 11" 13' - 1" 13' - 3" 8' - 10" 9' - 0" 9' - 1" 10' - 10" 10' - 11" 11' - 0" 12' - 1" 12' - 3" 12' - 4" 8' - 6" 8' - 7" 8' - 8" 10' - 4" 10' - 6" 10' - 7" 11' - 9" 11' - 11" 12' - 0" 7' - 11" 8' - 0" 8' - 1" 9' - 8" 9' - 9" 9' - 10" 11' - 1" 11' - 4" 11' - 6" 7' - 6" 7' - 7" 7' - 8" 9' - 2" 9' - 3" 9' - 4" 10' - 8" 10' - 10" 10' - 11" Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span. 110 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS BHF-36 Cellular Composite Deck 4.3 Light Weight Concrete (110 pcf) Maximum Unshored Spans Volume cy/100sf 3 1/2 0.776 1 Hour Fire Rating 1.085 2 Hour Fire Rating 1.162 3 Hour Fire Rating 1.452 D PANEL 5 11/16 C PANELS 4 3/4 N PANELS 4 1/2 0.931 Triple 10' - 7" 10' - 9" 10' - 10" 12' - 11" 13' - 1" 13' - 2" 13' - 4" 13' - 4" 13' - 4" 10' - 1" 10' - 3" 10' - 4" 12' - 4" 12' - 6" 12' - 7" 13' - 3" 13' - 4" 13' - 4" 9' - 8" 9' - 10" 9' - 11" 11' - 10" 11' - 11" 12' - 1" 12' - 10" 13' - 0" 13' - 2" 9' - 6" 9' - 7" 9' - 8" 11' - 7" 11' - 8" 11' - 10" 12' - 8" 12' - 10" 13' - 0" 8' - 11" 9' - 0" 9' - 1" 10' - 10" 10' - 11" 11' - 1" 12' - 1" 12' - 3" 12' - 5" B PANELS 4 ACUSTADEK® Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 110 pcf Light Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 26.7 9' - 3" 11' - 9" 27.2 9' - 4" 11' - 10" 27.7 9' - 6" 11' - 11" 27.3 11' - 3" 13' - 6" 27.8 11' - 6" 14' - 4" 28.3 11' - 8" 14' - 5" 28.0 11' - 10" 14' - 5" 28.5 12' - 1" 14' - 9" 29.0 12' - 3" 14' - 11" 31.3 8' - 9" 11' - 2" 31.7 8' - 11" 11' - 4" 32.3 9' - 0" 11' - 5" 31.9 10' - 9" 12' - 10" 32.4 11' - 0" 13' - 9" 32.9 11' - 3" 13' - 11" 32.6 11' - 5" 13' - 9" 33.1 11' - 8" 14' - 3" 33.6 11' - 10" 14' - 5" 35.9 8' - 4" 10' - 8" 36.3 8' - 6" 10' - 10" 36.8 8' - 7" 10' - 11" 36.5 10' - 4" 12' - 3" 37.0 10' - 7" 13' - 2" 37.5 10' - 10" 13' - 4" 37.2 11' - 0" 13' - 2" 37.7 11' - 3" 13' - 10" 38.2 11' - 6" 14' - 0" 38.1 8' - 2" 10' - 6" 38.6 8' - 4" 10' - 7" 39.1 8' - 5" 10' - 8" 38.8 10' - 2" 12' - 1" 39.3 10' - 5" 12' - 11" 39.8 10' - 7" 13' - 0" 39.5 10' - 10" 12' - 10" 39.9 11' - 1" 13' - 8" 40.5 11' - 4" 13' - 10" 46.7 7' - 7" 9' - 10" 47.2 7' - 9" 9' - 11" 47.7 7' - 10" 10' - 0" 47.4 9' - 6" 11' - 3" 47.9 9' - 9" 12' - 1" 48.4 10' - 0" 12' - 2" 48.1 10' - 2" 12' - 1" 48.5 10' - 5" 13' - 0" 49.1 10' - 8" 13' - 2" 2W PANELS Total Slab Depth (in) 3W PANELS BHF-36 Cellular Shoring Table Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span. www.ascsd.com GENERAL INFORMATION Composite and Non-Composite Deck Catalog • February 2016 111 TABLE OF CONTENTS 4.4 BH-36 Composite Deck 3 1⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 0.776yd3/100ft2 Gage 22 20 GA 22 Single 6' - 7" 7' - 10" 5'-0" 5'-6" ASD, W/Ω LRFD, ϕW L/360 523 837 - 428 685 - 2634 2318 2294 2271 32.1 26.57 2570 2283 2261 2241 psf in4/ft 5'-0" 5'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Single 8' - 11" 9' - 8" Double 10' - 7" 11' - 11" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 356 569 - 300 480 - 255 408 - 219 351 - 190 303 - 165 264 - 145 232 - 127 204 - 2517 2254 2234 2215 2489 2246 2227 2210 Icr = Iu = 2449 2414 2223 2204 2206 2188 2190 2173 17.4 in4/ft 35.7 in4/ft 2384 2187 2172 2158 2358 2172 2158 2144 2334 2159 2145 2133 Mno/Ω= ϕMno= ASD & LRFD - Superimposed Load, W (psf) LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Triple 11' - 2" 11' - 9" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 113 180 - 2324 2305 2158 2147 2145 2135 2133 2123 21.5 kip-in/ft 32.8 kip-in/ft 100 160 - 89 142 - 2287 2137 2125 2114 2271 2127 2116 2106 Vn/Ω = ϕ Vn = 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 760 638 532 450 385 332 286 238 201 171 146 126 110 ASD, W/Ω 1141 1021 852 720 615 531 462 404 356 316 281 251 225 LRFD, ϕW L/360 286 238 201 171 146 126 110 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3091 2984 2895 2861 2794 2735 2684 2639 2598 2591 2558 2527 2499 PAF Base Steel ≥ .25" 2563 2504 2455 2456 2417 2384 2354 2328 2305 2314 2294 2276 2259 PAF Base Steel ≥ 0.125" 2525 2469 2423 2426 2390 2358 2330 2306 2284 2293 2275 2257 2242 #12 Screw Base Steel ≥ .0385" 2498 2445 2401 2406 2370 2340 2314 2290 2269 2279 2261 2245 2230 Concrete + Deck = 33.2 psf Icr = 23.6 in4/ft Vn/Ω = Mno/Ω= 31.5 kip-in/ft 4 (Icr+Iu)/2 = 31.31 in /ft Iu = 39.0 in4/ft ϕ Vn = ϕMno= 48.1 kip-in/ft Vertical Load Span (in) 5'-0" 5'-0" 5'-6" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 760 691 634 542 464 377 311 259 218 186 159 137 120 ASD, W/Ω 1141 1037 951 868 742 641 559 490 433 385 343 307 276 LRFD, ϕW L/360 464 377 311 259 218 186 159 137 120 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3419 3281 3166 3135 3047 2971 2904 2845 2793 2791 2747 2707 2670 PAF Base Steel ≥ .25" 2740 2664 2600 2613 2562 2518 2480 2446 2416 2434 2407 2383 2361 PAF Base Steel ≥ 0.125" 2666 2597 2539 2556 2509 2469 2434 2402 2375 2395 2370 2348 2328 #12 Screw Base Steel ≥ .0385" 2679 2609 2551 2568 2522 2481 2446 2415 2387 2407 2383 2360 2340 Concrete + Deck = 33.8 psf Icr = 27.0 in4/ft Vn/Ω = Mno/Ω= 37.6 kip-in/ft (Icr+Iu)/2 = 34.04 in4/ft Iu = 41.0 in4/ft ϕ Vn = ϕMno= 57.6 kip-in/ft 79 127 - 71 113 - 2256 2243 2119 2111 2108 2101 2098 2092 1.90 kip/ft 2.85 kip/ft 11'-6" 12'-0" 87 154 87 77 139 77 2326 2309 2158 2149 2146 2136 2135 2126 1.90 kip/ft 2.85 kip/ft 11'-6" 12'-0" 96 203 96 85 183 85 2474 2450 2244 2231 2228 2215 2216 2203 1.90 kip/ft 2.85 kip/ft 11'-6" 12'-0" 105 250 105 92 226 92 2637 2606 2342 2323 2309 2293 2322 2305 1.90 kip/ft 2.85 kip/ft All Gages 16 Gage 18 16 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 615 504 420 354 302 260 225 197 173 153 132 114 100 ASD, W/Ω 984 806 671 566 483 416 361 315 277 244 217 193 172 LRFD, ϕW L/360 132 114 100 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2783 2705 2640 2609 2560 2518 2481 2448 2419 2410 2385 2364 2344 PAF Base Steel ≥ .25" 2398 2355 2319 2313 2285 2261 2240 2222 2206 2207 2193 2180 2169 PAF Base Steel ≥ 0.125" 2369 2328 2295 2290 2264 2242 2222 2205 2189 2192 2178 2166 2156 #12 Screw Base Steel ≥ .0385" 2344 2306 2274 2271 2247 2225 2207 2190 2176 2179 2166 2155 2144 Concrete + Deck = 32.5 psf Icr = 19.8 in4/ft Vn/Ω = Mno/Ω= 25.1 kip-in/ft (Icr+Iu)/2 = 28.33 in4/ft Iu = 36.9 in4/ft ϕ Vn = ϕMno= 38.4 kip-in/ft Vertical Load Span (in) 18 Triple 7' - 10" 9' - 4" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 6' - 11" 8' - 6" LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 6 in o.c. 3200 4550 5540 7340 10040 12 in o.c. 3200 4550 5540 7340 10040 18 in o.c. 3200 4550 5540 7340 8790 112 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS BH-36 Composite Deck 4.4 4" Total Slab Depth Normal Weight Concrete (145 pcf) Gage 22 20 22 5'-6" ASD, W/Ω LRFD, ϕW L/360 663 1060 - 543 868 - 3124 2809 2784 2762 38.2 39.42 3061 2774 2752 2731 psf in4/ft 5'-0" 5'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Double 10' - 1" 11' - 4" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 451 722 - 380 609 - 324 518 - 279 446 - 241 386 - 211 337 - 185 295 - 163 261 - 3008 2745 2724 2705 2979 2736 2717 2700 Icr = Iu = 2939 2905 2714 2695 2696 2678 2680 2663 25.4 in4/ft 53.4 in4/ft 2875 2678 2662 2648 2848 2663 2648 2635 2825 2649 2636 2623 Mno/Ω= ϕMno= ASD & LRFD - Superimposed Load, W (psf) LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Triple 10' - 8" 11' - 4" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 144 231 - 2815 2795 2649 2637 2636 2625 2624 2614 27.1 kip-in/ft 41.5 kip-in/ft 128 205 - 114 183 - 2777 2627 2615 2605 2761 2618 2607 2596 Vn/Ω = ϕ Vn = 5'-0" 11'-6" 12'-0" 124 198 - 112 179 - 2816 2799 2649 2639 2636 2627 2625 2617 2.26 kip/ft 3.40 kip/ft 11'-6" 12'-0" 143 262 143 126 237 126 2964 2941 2735 2721 2718 2705 2706 2694 2.26 kip/ft 3.40 kip/ft 11'-6" 12'-0" 155 323 155 136 292 136 3127 3097 2832 2814 2800 2783 2812 2795 2.26 kip/ft 3.40 kip/ft www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 113 ACUSTADEK® LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 6 in o.c. 3700 5050 6040 7840 10540 12 in o.c. 3700 5050 6040 7840 10540 18 in o.c. 3700 5050 6040 7840 8790 D PANEL 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 906 823 755 695 595 514 448 384 323 275 236 204 177 ASD, W/Ω 1358 1235 1132 1045 952 823 717 630 557 495 442 396 357 LRFD, ϕW L/360 384 323 275 236 204 177 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3910 3772 3657 3626 3538 3461 3395 3336 3283 3282 3237 3197 3161 PAF Base Steel ≥ .25" 3230 3154 3091 3103 3053 3009 2970 2936 2906 2924 2898 2874 2852 PAF Base Steel ≥ 0.125" 3157 3087 3029 3046 3000 2959 2924 2893 2865 2885 2861 2839 2818 #12 Screw Base Steel ≥ .0385" 3169 3100 3042 3059 3012 2972 2936 2905 2877 2898 2873 2851 2830 Concrete + Deck = 39.2 psf Icr = 39.8 in4/ft Vn/Ω = Mno/Ω= 48.0 kip-in/ft (Icr+Iu)/2 = 50.4 in4/ft Iu = 61.1 in4/ft ϕ Vn = ϕMno= 73.5 kip-in/ft 2747 2733 2609 2602 2599 2591 2589 2582 2.26 kip/ft 3.40 kip/ft C PANELS 5'-6" 91 146 - N PANELS 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 906 814 680 575 491 424 369 324 286 253 217 187 163 ASD, W/Ω 1358 1235 1087 919 786 679 591 518 457 405 361 323 290 LRFD, ϕW L/360 253 217 187 163 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3581 3474 3385 3352 3284 3226 3174 3129 3089 3082 3048 3017 2990 PAF Base Steel ≥ .25" 3053 2995 2945 2946 2907 2874 2845 2819 2796 2804 2784 2766 2750 PAF Base Steel ≥ 0.125" 3015 2960 2913 2916 2880 2848 2821 2796 2774 2784 2765 2748 2732 #12 Screw Base Steel ≥ .0385" 2988 2935 2891 2896 2861 2831 2804 2780 2760 2770 2752 2735 2720 Concrete + Deck = 39.8 psf Icr = 34.6 in4/ft Vn/Ω = Mno/Ω= 40.0 kip-in/ft 4 (Icr+Iu)/2 = 46.4 in /ft Iu = 58.2 in4/ft ϕ Vn = ϕMno= 61.3 kip-in/ft 5'-0" 5'-6" 102 163 - B PANELS All Gages Single 8' - 6" 9' - 2" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 780 640 533 450 384 331 287 251 221 195 173 155 138 ASD, W/Ω 1248 1024 853 720 614 529 459 402 353 312 277 247 221 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3273 3195 3130 3099 3050 3008 2971 2939 2910 2900 2876 2854 2834 PAF Base Steel ≥ .25" 2888 2845 2810 2803 2776 2752 2731 2712 2696 2698 2684 2671 2659 PAF Base Steel ≥ 0.125" 2859 2819 2785 2781 2755 2732 2713 2695 2680 2682 2669 2657 2646 #12 Screw Base Steel ≥ .0385" 2834 2796 2765 2762 2737 2716 2697 2681 2666 2669 2657 2645 2635 Concrete + Deck = 38.5 psf Icr = 28.8 in4/ft Vn/Ω = Mno/Ω= 31.7 kip-in/ft (Icr+Iu)/2 = 42 in4/ft Iu = 55.2 in4/ft ϕ Vn = ϕMno= 48.5 kip-in/ft Vertical Load Span (in) 16 Gage 18 16 2W PANELS 5'-0" Vertical Load Span (in) 18 Triple 7' - 5" 8' - 10" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 6' - 8" 8' - 2" 3W PANELS GA Single 6' - 3" 7' - 6" Concrete Volume 0.931yd3/100ft2 GENERAL INFORMATION TABLE OF CONTENTS 4.4 BH-36 Composite Deck 4 1⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.085yd3/100ft2 Gage 22 20 GA 22 Single 6' - 0" 7' - 2" 5'-0" 5'-6" ASD, W/Ω LRFD, ϕW L/360 809 1294 - 663 1060 - 3615 3299 3275 3252 44.2 55.87 3551 3264 3242 3221 psf in4/ft 5'-0" 5'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Single 8' - 2" 8' - 9" Double 9' - 8" 10' - 10" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 552 883 - 465 744 - 396 634 - 341 546 - 296 473 - 258 413 - 227 363 - 200 320 - 3498 3235 3215 3196 3469 3227 3208 3191 Icr = Iu = 3430 3395 3204 3185 3187 3169 3171 3154 35.2 in4/ft 76.6 in4/ft 3365 3168 3153 3139 3339 3153 3139 3125 3315 3140 3126 3114 Mno/Ω= ϕMno= ASD & LRFD - Superimposed Load, W (psf) LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Triple 10' - 2" 10' - 11" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 177 284 - 3305 3286 3139 3128 3126 3115 3114 3104 33.0 kip-in/ft 50.5 kip-in/ft 158 252 - 141 225 - 3268 3118 3106 3095 3252 3108 3097 3087 Vn/Ω = ϕ Vn = 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 1060 963 835 707 605 522 455 399 352 313 279 250 225 ASD, W/Ω 1590 1445 1325 1131 968 836 728 639 564 501 446 400 360 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 4071 3964 3875 3842 3775 3716 3665 3620 3579 3572 3538 3508 3480 PAF Base Steel ≥ .25" 3544 3485 3436 3436 3398 3364 3335 3309 3286 3295 3275 3257 3240 PAF Base Steel ≥ 0.125" 3505 3450 3404 3407 3370 3339 3311 3287 3265 3274 3255 3238 3223 #12 Screw Base Steel ≥ .0385" 3479 3426 3382 3386 3351 3321 3294 3271 3250 3260 3242 3226 3211 Concrete + Deck = 45.2 psf Icr = 48.2 in4/ft Vn/Ω = Mno/Ω= 49.1 kip-in/ft 4 (Icr+Iu)/2 = 65.67 in /ft Iu = 83.1 in4/ft ϕ Vn = ϕMno= 75.1 kip-in/ft Vertical Load Span (in) 5'-0" 5'-0" 5'-6" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 1060 963 883 815 734 635 554 487 430 383 334 288 251 ASD, W/Ω 1590 1445 1325 1223 1136 1016 886 779 689 613 547 491 443 LRFD, ϕW L/360 334 288 251 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 4400 4262 4147 4116 4028 3952 3885 3826 3774 3772 3728 3688 3651 PAF Base Steel ≥ .25" 3721 3645 3581 3594 3543 3499 3461 3427 3397 3415 3388 3364 3342 PAF Base Steel ≥ 0.125" 3647 3578 3520 3537 3490 3450 3414 3383 3356 3376 3351 3329 3309 #12 Screw Base Steel ≥ .0385" 3660 3590 3532 3549 3503 3462 3427 3396 3368 3388 3363 3341 3321 Concrete + Deck = 45.9 psf Icr = 55.6 in4/ft Vn/Ω = Mno/Ω= 59.1 kip-in/ft (Icr+Iu)/2 = 71.36 in4/ft Iu = 87.1 in4/ft ϕ Vn = ϕMno= 90.4 kip-in/ft 126 202 - 113 181 - 3237 3223 3100 3092 3089 3082 3079 3072 2.65 kip/ft 3.97 kip/ft 11'-6" 12'-0" 153 245 - 138 221 - 3306 3290 3139 3130 3126 3117 3116 3107 2.65 kip/ft 3.97 kip/ft 11'-6" 12'-0" 202 324 202 178 293 178 3455 3431 3225 3211 3208 3195 3197 3184 2.65 kip/ft 3.97 kip/ft 11'-6" 12'-0" 219 400 219 193 363 193 3618 3587 3322 3304 3290 3273 3302 3285 2.65 kip/ft 3.97 kip/ft All Gages 16 Gage 18 16 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 954 783 652 551 470 405 352 308 271 240 213 190 171 ASD, W/Ω 1527 1252 1044 881 753 649 564 493 434 384 342 305 273 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3763 3686 3621 3590 3541 3499 3462 3429 3400 3390 3366 3344 3325 PAF Base Steel ≥ .25" 3379 3336 3300 3294 3266 3242 3221 3203 3186 3188 3174 3161 3150 PAF Base Steel ≥ 0.125" 3349 3309 3276 3271 3245 3223 3203 3186 3170 3173 3159 3147 3136 #12 Screw Base Steel ≥ .0385" 3325 3287 3255 3252 3228 3206 3188 3171 3156 3160 3147 3136 3125 Concrete + Deck = 44.6 psf Icr = 40.0 in4/ft Vn/Ω = Mno/Ω= 38.7 kip-in/ft (Icr+Iu)/2 = 59.46 in4/ft Iu = 78.9 in4/ft ϕ Vn = ϕMno= 59.3 kip-in/ft Vertical Load Span (in) 18 Triple 7' - 1" 8' - 5" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 6' - 6" 7' - 10" LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 6 in o.c. 4190 5540 6530 8330 11030 12 in o.c. 4190 5540 6530 8330 11030 18 in o.c. 4190 5540 6530 8330 8790 114 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS BH-36 Composite Deck 4.4 5" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.239yd3/100ft2 1 Hour Fire Rating Gage 22 20 22 5'-6" ASD, W/Ω LRFD, ϕW L/360 960 1536 - 787 1259 - 4105 3790 3765 3743 50.3 76.31 4042 3755 3732 3712 psf in4/ft 5'-0" 5'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Double 9' - 3" 10' - 5" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 655 1048 - 553 884 - 471 754 - 406 649 - 352 563 - 308 492 - 270 432 - 239 382 - 3988 3725 3705 3686 3960 3717 3698 3681 Icr = Iu = 3920 3695 3677 3661 46.8 105.8 3886 3675 3659 3644 in4/ft in4/ft 3856 3658 3643 3629 3829 3643 3629 3616 3805 3630 3616 3604 Mno/Ω= ϕMno= ASD & LRFD - Superimposed Load, W (psf) LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Triple 9' - 9" 10' - 6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 212 339 - 3796 3776 3629 3618 3617 3606 3605 3595 39.1 kip-in/ft 59.9 kip-in/ft 189 302 - 168 270 - 3758 3608 3596 3586 3742 3599 3588 3577 Vn/Ω = ϕ Vn = 5'-0" 11'-6" 12'-0" 184 294 - 166 265 - 3797 3780 3630 3620 3617 3608 3606 3597 3.06 kip/ft 4.59 kip/ft 11'-6" 12'-0" 244 390 - 221 353 - 3945 3922 3716 3702 3699 3686 3687 3675 3.06 kip/ft 4.59 kip/ft 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 411 658 - 369 591 - 333 533 - 4218 3879 3842 3854 kip-in/ft kip-in/ft 4178 3855 3819 3832 4142 3833 3799 3811 Vn/Ω = ϕ Vn = 299 482 299 263 438 263 4108 4078 3813 3795 3781 3764 3793 3776 3.06 kip/ft 4.59 kip/ft www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 115 ACUSTADEK® LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 6 in o.c. n/a 6030 7020 8820 11520 12 in o.c. n/a 6030 7020 8820 11520 18 in o.c. n/a 6030 7020 8790 8790 D PANEL 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" ASD & LRFD - Superimposed Load, W (psf) 1223 1112 1019 941 874 761 664 584 517 460 ASD, W/Ω 1835 1668 1529 1411 1311 1218 1063 934 827 735 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 4890 4753 4638 4607 4519 4442 4376 4317 4264 4263 PAF Base Steel ≥ .25" 4211 4135 4072 4084 4033 3989 3951 3917 3887 3905 PAF Base Steel ≥ 0.125" 4137 4068 4010 4027 3981 3940 3905 3874 3846 3866 #12 Screw Base Steel ≥ .0385" 4150 4081 4023 4040 3993 3953 3917 3886 3858 3879 Concrete + Deck = 52.0 psf Icr = 74.7 in4/ft Mno/Ω= 70.6 (Icr+Iu)/2 = 97.25 in4/ft Iu = 119.8 in4/ft ϕMno= 108.0 3727 3714 3590 3582 3580 3572 3570 3563 3.06 kip/ft 4.59 kip/ft C PANELS 5'-6" 136 217 - N PANELS 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 1223 1112 998 844 723 625 544 478 422 375 334 300 270 ASD, W/Ω 1835 1668 1529 1351 1156 999 871 764 675 600 535 480 432 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 4562 4455 4366 4333 4265 4206 4155 4110 4070 4063 4029 3998 3970 PAF Base Steel ≥ .25" 4034 3975 3926 3927 3888 3855 3826 3800 3777 3785 3765 3747 3731 PAF Base Steel ≥ 0.125" 3996 3940 3894 3897 3861 3829 3801 3777 3755 3765 3746 3729 3713 #12 Screw Base Steel ≥ .0385" 3969 3916 3872 3877 3842 3811 3785 3761 3741 3751 3732 3716 3701 Concrete + Deck = 51.3 psf Icr = 64.6 in4/ft Vn/Ω = Mno/Ω= 58.5 kip-in/ft 4 (Icr+Iu)/2 = 89.54 in /ft Iu = 114.5 in4/ft ϕ Vn = ϕMno= 89.5 kip-in/ft 5'-0" 5'-6" 151 241 - B PANELS All Gages Single 7' - 10" 8' - 5" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 1134 931 776 656 560 483 420 368 324 287 255 228 204 ASD, W/Ω 1815 1489 1242 1049 896 773 672 588 518 459 408 365 327 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 4254 4176 4111 4080 4031 3989 3952 3920 3891 3881 3857 3835 3815 PAF Base Steel ≥ .25" 3869 3826 3791 3784 3757 3733 3712 3693 3677 3678 3664 3652 3640 PAF Base Steel ≥ 0.125" 3840 3800 3766 3762 3736 3713 3693 3676 3661 3663 3650 3638 3627 #12 Screw Base Steel ≥ .0385" 3815 3777 3746 3743 3718 3697 3678 3662 3647 3650 3637 3626 3616 Concrete + Deck = 50.6 psf Icr = 53.4 in4/ft Vn/Ω = Mno/Ω= 46.0 kip-in/ft (Icr+Iu)/2 = 81.12 in4/ft Iu = 108.9 in4/ft ϕ Vn = ϕMno= 70.3 kip-in/ft Vertical Load Span (in) 16 Gage 18 16 2W PANELS 5'-0" Vertical Load Span (in) 18 Triple 6' - 10" 8' - 1" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 6' - 3" 7' - 7" 3W PANELS GA Single 5' - 9" 6' - 10" GENERAL INFORMATION TABLE OF CONTENTS 4.4 BH-36 Composite Deck 6" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.548yd3/100ft2 2 Hour Fire Rating Gage 22 20 GA 22 Single 5' - 4" 6' - 4" 5'-0" 5'-6" ASD, W/Ω LRFD, ϕW L/360 1273 2036 - 1044 1670 - 5086 4771 4746 4724 62.4 130.7 5022 4736 4713 4693 psf in4/ft 5'-0" 5'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Single 7' - 4" 7' - 11" Double 8' - 8" 9' - 8" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 869 1391 - 734 1174 - 626 1002 - 540 863 - 469 750 - 410 656 - 360 577 - 319 510 - 4969 4706 4686 4667 4941 4698 4679 4662 Icr = Iu = 4901 4676 4658 4642 75.7 185.8 4867 4656 4640 4625 in4/ft in4/ft 4836 4639 4624 4610 4810 4624 4610 4597 4786 4611 4597 4585 Mno/Ω= ϕMno= ASD & LRFD - Superimposed Load, W (psf) LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Triple 9' - 0" 9' - 10" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 283 453 - 4776 4757 4610 4599 4597 4587 4586 4576 51.7 kip-in/ft 79.2 kip-in/ft 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" ASD & LRFD - Superimposed Load, W (psf) 1577 1434 1315 1130 968 837 730 641 567 504 ASD, W/Ω 2366 2151 1972 1808 1548 1339 1167 1025 907 806 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 5543 5436 5347 5314 5246 5187 5136 5091 5051 5043 PAF Base Steel ≥ .25" 5015 4956 4907 4908 4869 4836 4806 4781 4758 4766 PAF Base Steel ≥ 0.125" 4977 4921 4875 4878 4842 4810 4782 4758 4736 4746 #12 Screw Base Steel ≥ .0385" 4950 4897 4853 4858 4823 4792 4766 4742 4721 4732 Concrete + Deck = 63.4 psf Icr = 105.7 in4/ft Mno/Ω= 78.0 4 (Icr+Iu)/2 = 152.7 in /ft Iu = 199.7 in4/ft ϕMno= 119.4 Vertical Load Span (in) 252 404 - 226 361 - 4739 4589 4577 4566 4723 4580 4568 4558 Vn/Ω = ϕ Vn = 5'-0" 5'-0" 5'-6" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" ASD & LRFD - Superimposed Load, W (psf) 1577 1434 1315 1213 1127 1023 894 786 696 620 ASD, W/Ω 2366 2151 1972 1820 1690 1577 1430 1258 1114 992 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 5871 5734 5619 5587 5499 5423 5356 5298 5245 5244 PAF Base Steel ≥ .25" 5192 5116 5053 5065 5014 4970 4932 4898 4868 4886 PAF Base Steel ≥ 0.125" 5118 5049 4991 5008 4962 4921 4886 4855 4827 4847 #12 Screw Base Steel ≥ .0385" 5131 5061 5004 5021 4974 4933 4898 4867 4839 4859 Concrete + Deck = 64.0 psf Icr = 122.9 in4/ft Mno/Ω= 94.5 (Icr+Iu)/2 = 165.6 in4/ft Iu = 208.3 in4/ft ϕMno= 144.7 203 324 - 182 292 - 4708 4695 4571 4563 4560 4553 4551 4544 3.94 kip/ft 5.92 kip/ft 11'-6" 12'-0" 247 395 - 223 356 - 4778 4761 4610 4601 4598 4589 4587 4578 3.94 kip/ft 5.92 kip/ft 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 450 720 - 404 646 - 364 582 - 5010 4746 4727 4713 kip-in/ft kip-in/ft 4979 4728 4710 4697 4951 4711 4694 4682 Vn/Ω = ϕ Vn = 329 526 - 298 477 - 4926 4903 4696 4683 4680 4667 4668 4656 3.94 kip/ft 5.92 kip/ft 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 555 888 - 499 798 - 450 720 - 5199 4859 4823 4835 kip-in/ft kip-in/ft 5159 4835 4800 4812 5122 4814 4780 4792 Vn/Ω = ϕ Vn = 408 652 - 371 593 - 5089 5058 4794 4775 4762 4745 4774 4757 3.94 kip/ft 5.92 kip/ft All Gages 16 Gage 18 16 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 1507 1237 1032 872 746 644 560 491 433 383 341 305 274 ASD, W/Ω 2366 1979 1651 1396 1193 1030 896 785 692 613 546 489 438 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 5235 5157 5092 5061 5012 4970 4933 4900 4871 4862 4838 4816 4796 PAF Base Steel ≥ .25" 4850 4807 4771 4765 4737 4714 4693 4674 4658 4659 4645 4633 4621 PAF Base Steel ≥ 0.125" 4821 4781 4747 4743 4717 4694 4674 4657 4641 4644 4631 4619 4608 #12 Screw Base Steel ≥ .0385" 4796 4758 4726 4724 4699 4678 4659 4642 4628 4631 4618 4607 4597 Concrete + Deck = 62.7 psf Icr = 86.6 in4/ft Vn/Ω = Mno/Ω= 60.9 kip-in/ft (Icr+Iu)/2 = 138.6 in4/ft Iu = 190.6 in4/ft ϕ Vn = ϕMno= 93.2 kip-in/ft Vertical Load Span (in) 18 Triple 6' - 4" 7' - 6" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 5' - 11" 7' - 1" LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 6 in o.c. n/a 7020 8010 9810 12510 12 in o.c. n/a 7020 8010 9810 12510 18 in o.c. n/a 7020 8010 8790 8790 116 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS BH-36 Composite Deck 4.4 6 3⁄4" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.780yd3/100ft2 3 Hour Fire Rating Gage 22 20 22 5'-6" ASD, W/Ω LRFD, ϕW L/360 1513 2420 - 1241 1986 - 5822 5506 5482 5459 71.4 184.9 5758 5471 5449 5428 psf in4/ft 5'-0" 5'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Double 8' - 3" 9' - 2" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 1034 1655 - 873 1397 - 746 1193 - 643 1028 - 558 893 - 488 781 - 430 688 - 380 609 - 5705 5442 5422 5403 5676 5434 5415 5397 Icr = Iu = 5637 5411 5394 5378 102.5 267.4 5602 5392 5376 5361 in4/ft in4/ft 5572 5375 5360 5345 5546 5360 5346 5332 5522 5347 5333 5320 Mno/Ω= ϕMno= ASD & LRFD - Superimposed Load, W (psf) LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern 5'-0" 270 432 - 5475 5324 5313 5302 5459 5315 5304 5294 Vn/Ω = ϕ Vn = 243 388 - 218 349 - 5444 5430 5307 5299 5296 5289 5286 5279 4.67 kip/ft 7.00 kip/ft 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 408 653 - 365 584 - 328 525 - 5573 5381 5366 5354 kip-in/ft kip-in/ft 5551 5368 5354 5343 5532 5357 5343 5332 Vn/Ω = ϕ Vn = 295 473 - 267 427 - 5513 5497 5346 5336 5333 5324 5323 5314 4.67 kip/ft 7.00 kip/ft 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 539 863 - 484 774 - 436 698 - 5745 5482 5462 5449 kip-in/ft kip-in/ft 5715 5464 5445 5433 5687 5447 5430 5418 Vn/Ω = ϕ Vn = 394 631 - 358 572 - 5661 5638 5432 5418 5415 5402 5404 5391 4.67 kip/ft 7.00 kip/ft 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 666 1066 - 599 958 - 541 865 - 5935 5595 5558 5570 kip-in/ft kip-in/ft 5895 5571 5536 5548 5858 5549 5516 5528 Vn/Ω = ϕ Vn = 490 784 - 446 713 - 5825 5794 5529 5511 5497 5480 5509 5492 4.67 kip/ft 7.00 kip/ft www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 117 ACUSTADEK® LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 6 in o.c. n/a 7760 8750 10550 13250 12 in o.c. n/a 7760 8750 10550 13180 18 in o.c. n/a 7760 8750 8790 8790 D PANEL 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" ASD & LRFD - Superimposed Load, W (psf) 1867 1697 1556 1436 1334 1227 1071 943 835 744 ASD, W/Ω 2801 2546 2334 2154 2000 1867 1714 1508 1336 1190 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 6607 6469 6354 6323 6235 6159 6092 6033 5981 5979 PAF Base Steel ≥ .25" 5928 5852 5788 5801 5750 5706 5668 5634 5603 5622 PAF Base Steel ≥ 0.125" 5854 5785 5727 5744 5697 5657 5621 5590 5562 5583 #12 Screw Base Steel ≥ .0385" 5866 5797 5739 5756 5710 5669 5634 5602 5575 5595 Concrete + Deck = 73.1 psf Icr = 168.1 in4/ft Mno/Ω= 113.1 (Icr+Iu)/2 = 232.9 in4/ft Iu = 297.7 in4/ft ϕMno= 173.0 302 483 - C PANELS 5'-6" 338 541 - N PANELS 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" ASD & LRFD - Superimposed Load, W (psf) 1867 1697 1556 1350 1157 1001 873 767 678 603 ASD, W/Ω 2801 2546 2334 2154 1851 1601 1397 1227 1085 965 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 6278 6171 6082 6049 5982 5923 5872 5826 5786 5779 PAF Base Steel ≥ .25" 5751 5692 5643 5643 5605 5571 5542 5516 5493 5501 PAF Base Steel ≥ 0.125" 5712 5657 5611 5614 5577 5546 5518 5494 5472 5481 #12 Screw Base Steel ≥ .0385" 5686 5633 5589 5593 5558 5528 5501 5478 5457 5467 Concrete + Deck = 72.4 psf Icr = 144.0 in4/ft Mno/Ω= 93.1 4 (Icr+Iu)/2 = 215.1 in /ft Iu = 286.1 in4/ft ϕMno= 142.4 5'-0" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 5512 5492 5346 5335 5333 5322 5321 5311 61.4 kip-in/ft 94.0 kip-in/ft 5'-6" Triple 8' - 7" 9' - 5" B PANELS All Gages Single 7' - 0" 7' - 7" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" ASD & LRFD - Superimposed Load, W (psf) 1794 1473 1229 1039 889 767 668 585 516 458 ASD, W/Ω 2801 2357 1967 1663 1422 1228 1068 937 826 733 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 5970 5893 5828 5797 5748 5706 5669 5636 5607 5597 PAF Base Steel ≥ .25" 5586 5543 5507 5501 5473 5449 5428 5410 5393 5395 PAF Base Steel ≥ 0.125" 5556 5516 5483 5478 5452 5430 5410 5393 5377 5380 #12 Screw Base Steel ≥ .0385" 5532 5494 5462 5459 5435 5413 5395 5378 5363 5367 Concrete + Deck = 71.8 psf Icr = 117.5 in4/ft Mno/Ω= 72.4 (Icr+Iu)/2 = 195.7 in4/ft Iu = 273.9 in4/ft ϕMno= 110.8 Vertical Load Span (in) 16 Gage 18 16 2W PANELS 5'-0" Vertical Load Span (in) 18 Triple 6' - 0" 7' - 1" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 5' - 8" 6' - 10" 3W PANELS GA Single 5' - 1" 6' - 1" GENERAL INFORMATION TABLE OF CONTENTS 4.4 BH-36 Composite Deck 3 1⁄2" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 0.776yd3/100ft2 Gage 22 20 GA 22 Single 7' - 1" 8' - 7" 5'-0" 5'-6" ASD, W/Ω LRFD, ϕW L/360 497 796 - 408 653 - 1978 1663 1638 1616 24.8 30.97 1915 1628 1606 1585 psf in4/ft 5'-0" 5'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Single 9' - 9" 10' - 6" Double 11' - 4" 12' - 11" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 340 544 - 287 459 - 245 391 - 211 337 - 183 293 - 156 256 156 131 225 131 112 199 112 1862 1599 1578 1559 1833 1590 1571 1554 Icr = Iu = 1793 1759 1568 1549 1550 1532 1534 1517 23.1 in4/ft 38.8 in4/ft 1729 1532 1516 1502 1702 1517 1502 1489 1679 1503 1490 1477 Mno/Ω= ϕMno= ASD & LRFD - Superimposed Load, W (psf) LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Triple 12' - 0" 12' - 7" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 96 177 96 1669 1649 1503 1491 1490 1479 1478 1468 20.2 kip-in/ft 31.0 kip-in/ft 83 157 83 72 141 72 1631 1481 1469 1459 1615 1472 1461 1450 Vn/Ω = ϕ Vn = 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 99 86 570 518 475 416 333 271 223 186 157 133 114 ASD, W/Ω 1141 957 799 676 579 500 436 383 338 300 268 240 216 LRFD, ϕW L/360 416 333 271 223 186 157 133 114 99 86 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2441 2334 2245 2212 2144 2086 2034 1989 1949 1942 1908 1877 1849 PAF Base Steel ≥ .25" 1913 1854 1805 1806 1767 1734 1705 1679 1656 1664 1644 1626 1610 PAF Base Steel ≥ 0.125" 1875 1819 1773 1776 1740 1708 1681 1656 1634 1644 1625 1608 1592 #12 Screw Base Steel ≥ .0385" 1848 1795 1751 1756 1721 1690 1664 1640 1620 1630 1612 1595 1580 Concrete + Deck = 25.8 psf Icr = 30.6 in4/ft Vn/Ω = Mno/Ω= 29.3 kip-in/ft Iu = 43.3 in4/ft (Icr+Iu)/2 = 36.95 in4/ft ϕ Vn = ϕMno= 44.8 kip-in/ft Vertical Load Span (in) 5'-0" 5'-0" 5'-6" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 570 518 475 439 363 295 243 203 171 145 125 108 94 ASD, W/Ω 1141 1037 951 808 692 599 523 459 406 361 323 290 261 LRFD, ϕW L/360 363 295 243 203 171 145 125 108 94 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2774 2636 2521 2490 2402 2325 2259 2200 2147 2146 2101 2061 2025 PAF Base Steel ≥ .25" 2094 2018 1955 1967 1916 1873 1834 1800 1770 1788 1762 1738 1716 PAF Base Steel ≥ 0.125" 2020 1951 1893 1910 1864 1823 1788 1757 1729 1749 1725 1703 1682 #12 Screw Base Steel ≥ .0385" 2029 1960 1902 1919 1872 1832 1796 1765 1737 1758 1733 1711 1690 Concrete + Deck = 26.5 psf Icr = 34.6 in4/ft Vn/Ω = Mno/Ω= 34.8 kip-in/ft (Icr+Iu)/2 = 40.33 in4/ft Iu = 46.0 in4/ft ϕ Vn = ϕMno= 53.2 kip-in/ft 63 126 63 55 114 55 1601 1587 1463 1456 1453 1445 1443 1436 1.43 kip/ft 2.85 kip/ft 11'-6" 12'-0" 67 151 67 59 137 59 1672 1655 1505 1495 1492 1483 1481 1473 1.43 kip/ft 2.85 kip/ft 11'-6" 12'-0" 75 195 75 66 177 66 1824 1801 1595 1581 1578 1565 1566 1554 1.43 kip/ft 2.85 kip/ft 11'-6" 12'-0" 82 236 82 72 215 72 1991 1961 1696 1678 1664 1647 1672 1655 1.43 kip/ft 2.85 kip/ft All Gages 16 Gage 18 16 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 570 477 398 336 287 243 200 167 141 120 103 89 77 ASD, W/Ω 930 763 637 538 460 397 345 302 266 236 210 188 168 LRFD, ϕW L/360 243 200 167 141 120 103 89 77 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2129 2051 1986 1955 1906 1864 1827 1795 1766 1756 1732 1710 1690 PAF Base Steel ≥ .25" 1744 1701 1666 1659 1632 1608 1587 1568 1552 1554 1540 1527 1515 PAF Base Steel ≥ 0.125" 1715 1675 1641 1637 1611 1588 1569 1551 1536 1538 1525 1513 1502 #12 Screw Base Steel ≥ .0385" 1690 1652 1621 1618 1593 1572 1553 1537 1522 1525 1513 1501 1491 Concrete + Deck = 25.1 psf Icr = 26.0 in4/ft Vn/Ω = Mno/Ω= 23.5 kip-in/ft (Icr+Iu)/2 = 33.23 in4/ft Iu = 40.5 in4/ft ϕ Vn = ϕMno= 36.0 kip-in/ft Vertical Load Span (in) 18 Triple 8' - 6" 10' - 2" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 7' - 2" 9' - 0" LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 6 in o.c. 2720 4070 5060 6860 9560 12 in o.c. 2720 4070 5060 6860 9560 18 in o.c. 2720 4070 5060 6860 8790 118 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS BH-36 Composite Deck 4.4 4" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 0.931yd3/100ft2 1 Hour Fire Rating Gage 22 20 22 5'-6" ASD, W/Ω LRFD, ϕW L/360 633 1013 - 519 831 - 2303 1987 1962 1940 29.4 45.86 2239 1952 1930 1909 psf in4/ft 5'-0" 5'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Double 10' - 11" 12' - 4" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 433 692 - 365 585 - 312 499 - 269 430 - 234 374 - 205 327 - 180 288 - 159 255 - 2186 1923 1902 1883 2157 1914 1896 1878 Icr = Iu = 2117 2083 1892 1873 1874 1856 1858 1841 33.8 in4/ft 57.9 in4/ft 2053 1856 1840 1826 2026 1841 1826 1813 2003 1827 1814 1801 Mno/Ω= ϕMno= ASD & LRFD - Superimposed Load, W (psf) LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Triple 11' - 7" 12' - 1" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 142 227 142 1993 1973 1827 1815 1814 1803 1802 1792 25.7 kip-in/ft 39.3 kip-in/ft 122 202 122 106 181 106 1955 1805 1793 1783 1939 1796 1785 1774 Vn/Ω = ϕ Vn = 5'-0" 11'-6" 12'-0" 100 195 100 88 176 88 1996 1979 1829 1819 1816 1807 1805 1797 1.70 kip/ft 3.40 kip/ft 11'-6" 12'-0" 111 252 111 98 229 98 2148 2125 1919 1905 1902 1889 1890 1878 1.70 kip/ft 3.40 kip/ft 11'-6" 12'-0" 121 307 121 107 279 107 2315 2285 2020 2002 1988 1971 1996 1979 1.70 kip/ft 3.40 kip/ft www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 119 ACUSTADEK® LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 6 in o.c. 3090 4440 5430 7230 9930 12 in o.c. 3090 4440 5430 7230 9930 18 in o.c. 3090 4440 5430 7230 8790 D PANEL 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 679 617 566 522 485 437 360 300 253 215 184 159 138 ASD, W/Ω 1358 1235 1132 1040 892 772 674 593 525 467 418 376 339 LRFD, ϕW L/360 437 360 300 253 215 184 159 138 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3098 2960 2845 2814 2726 2649 2583 2524 2471 2470 2425 2385 2349 PAF Base Steel ≥ .25" 2418 2342 2279 2291 2241 2197 2158 2124 2094 2112 2086 2062 2040 PAF Base Steel ≥ 0.125" 2345 2275 2217 2234 2188 2147 2112 2081 2053 2073 2049 2027 2006 #12 Screw Base Steel ≥ .0385" 2353 2284 2226 2243 2196 2156 2120 2089 2061 2082 2057 2035 2015 Concrete + Deck = 31.1 psf Icr = 51.0 in4/ft Vn/Ω = Mno/Ω= 44.6 kip-in/ft (Icr+Iu)/2 = 59.64 in4/ft Iu = 68.2 in4/ft ϕ Vn = ϕMno= 68.3 kip-in/ft 1925 1911 1787 1780 1777 1769 1767 1760 1.70 kip/ft 3.40 kip/ft C PANELS 5'-6" 82 147 82 N PANELS 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 679 617 566 522 465 400 330 275 232 197 169 146 127 ASD, W/Ω 1358 1227 1025 868 743 643 561 492 435 387 346 310 279 LRFD, ϕW L/360 400 330 275 232 197 169 146 127 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2765 2658 2569 2536 2468 2410 2358 2313 2273 2266 2232 2201 2174 PAF Base Steel ≥ .25" 2237 2179 2129 2130 2091 2058 2029 2003 1980 1988 1968 1950 1934 PAF Base Steel ≥ 0.125" 2199 2144 2097 2100 2064 2032 2005 1980 1958 1968 1949 1932 1916 #12 Screw Base Steel ≥ .0385" 2172 2119 2075 2080 2045 2015 1988 1965 1944 1954 1936 1919 1904 Concrete + Deck = 30.4 psf Icr = 45.0 in4/ft Vn/Ω = Mno/Ω= 37.5 kip-in/ft 4 (Icr+Iu)/2 = 54.67 in /ft Iu = 64.4 in4/ft ϕ Vn = ϕMno= 57.3 kip-in/ft 5'-0" 5'-6" 93 163 93 B PANELS All Gages Single 9' - 3" 10' - 0" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 679 608 508 429 367 317 276 242 208 177 152 131 114 ASD, W/Ω 1186 974 812 687 587 507 441 387 341 303 270 241 217 LRFD, ϕW L/360 208 177 152 131 114 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2453 2375 2310 2279 2231 2188 2151 2119 2090 2080 2056 2034 2014 PAF Base Steel ≥ .25" 2068 2025 1990 1983 1956 1932 1911 1892 1876 1878 1864 1851 1839 PAF Base Steel ≥ 0.125" 2039 1999 1965 1961 1935 1912 1893 1875 1860 1862 1849 1837 1826 #12 Screw Base Steel ≥ .0385" 2014 1976 1945 1942 1917 1896 1877 1861 1846 1849 1837 1825 1815 Concrete + Deck = 29.7 psf Icr = 38.1 in4/ft Vn/Ω = Mno/Ω= 29.9 kip-in/ft (Icr+Iu)/2 = 49.16 in4/ft Iu = 60.3 in4/ft ϕ Vn = ϕMno= 45.8 kip-in/ft Vertical Load Span (in) 16 Gage 18 16 2W PANELS 5'-0" Vertical Load Span (in) 18 Triple 8' - 1" 9' - 8" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 7' - 0" 8' - 8" 3W PANELS GA Single 6' - 10" 8' - 2" GENERAL INFORMATION TABLE OF CONTENTS 4.4 BH-36 Composite Deck 4 1⁄2" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.085yd3/100ft2 Gage 22 20 GA 22 Single 6' - 6" 7' - 10" 5'-0" 5'-6" ASD, W/Ω LRFD, ϕW L/360 776 1242 - 637 1019 - 2627 2311 2287 2264 34.0 64.87 2563 2276 2254 2233 psf in4/ft 5'-0" 5'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Single 8' - 11" 9' - 7" Double 10' - 6" 11' - 10" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 531 850 - 449 718 - 383 614 - 331 529 - 288 460 - 252 403 - 222 355 - 197 314 - 2510 2247 2226 2207 2481 2238 2220 2202 Icr = Iu = 2441 2407 2216 2197 2199 2180 2182 2165 47.1 in4/ft 82.6 in4/ft 2377 2180 2164 2150 2350 2165 2150 2137 2327 2151 2138 2125 Mno/Ω= ϕMno= ASD & LRFD - Superimposed Load, W (psf) LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Triple 11' - 1" 11' - 9" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 175 280 - 2317 2297 2151 2139 2138 2127 2126 2116 31.4 kip-in/ft 48.1 kip-in/ft 156 250 - 140 224 - 2279 2129 2118 2107 2263 2120 2109 2099 Vn/Ω = ϕ Vn = 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 568 497 434 381 328 279 239 206 179 795 723 662 611 ASD, W/Ω 1590 1445 1267 1073 919 796 694 610 540 480 429 385 347 LRFD, ϕW L/360 328 279 239 206 179 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3089 2982 2893 2860 2792 2734 2682 2637 2597 2590 2556 2525 2498 PAF Base Steel ≥ .25" 2561 2503 2453 2454 2415 2382 2353 2327 2304 2312 2292 2274 2258 PAF Base Steel ≥ 0.125" 2523 2468 2421 2425 2388 2356 2329 2304 2283 2292 2273 2256 2240 #12 Screw Base Steel ≥ .0385" 2496 2443 2399 2404 2369 2339 2312 2289 2268 2278 2260 2243 2228 Concrete + Deck = 35.0 psf Icr = 63.0 in4/ft Vn/Ω = Mno/Ω= 46.2 kip-in/ft 4 (Icr+Iu)/2 = 77.32 in /ft Iu = 91.6 in4/ft ϕ Vn = ϕMno= 70.7 kip-in/ft Vertical Load Span (in) 5'-0" 5'-0" 5'-6" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 795 723 662 611 568 530 497 424 357 304 261 225 196 ASD, W/Ω 1590 1445 1325 1223 1107 959 837 737 653 581 521 468 423 LRFD, ϕW L/360 424 357 304 261 225 196 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3422 3284 3169 3138 3050 2974 2907 2848 2796 2794 2749 2709 2673 PAF Base Steel ≥ .25" 2742 2666 2603 2615 2565 2521 2482 2448 2418 2436 2410 2386 2364 PAF Base Steel ≥ 0.125" 2669 2599 2541 2559 2512 2471 2436 2405 2377 2397 2373 2351 2330 #12 Screw Base Steel ≥ .0385" 2677 2608 2550 2567 2520 2480 2444 2413 2385 2406 2381 2359 2339 Concrete + Deck = 35.7 psf Icr = 71.7 in4/ft Vn/Ω = Mno/Ω= 55.2 kip-in/ft (Icr+Iu)/2 = 84.35 in4/ft Iu = 97.0 in4/ft ϕ Vn = ϕMno= 84.5 kip-in/ft 126 202 - 114 182 - 2249 2235 2111 2104 2101 2093 2091 2084 1.99 kip/ft 3.97 kip/ft 11'-6" 12'-0" 141 242 141 124 219 124 2320 2304 2153 2143 2140 2131 2129 2121 1.99 kip/ft 3.97 kip/ft 11'-6" 12'-0" 157 314 157 138 285 138 2472 2449 2243 2229 2226 2213 2215 2202 1.99 kip/ft 3.97 kip/ft 11'-6" 12'-0" 171 383 171 151 348 151 2639 2609 2344 2326 2312 2295 2320 2303 1.99 kip/ft 3.97 kip/ft All Gages 16 Gage 18 16 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 795 723 624 528 452 390 340 298 263 234 208 185 161 ASD, W/Ω 1457 1197 999 845 723 625 544 477 421 374 333 298 268 LRFD, ϕW L/360 185 161 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2777 2699 2634 2603 2555 2512 2475 2443 2414 2404 2380 2358 2338 PAF Base Steel ≥ .25" 2392 2350 2314 2307 2280 2256 2235 2217 2200 2202 2188 2175 2163 PAF Base Steel ≥ 0.125" 2363 2323 2289 2285 2259 2236 2217 2199 2184 2186 2173 2161 2150 #12 Screw Base Steel ≥ .0385" 2338 2300 2269 2266 2241 2220 2201 2185 2170 2173 2161 2149 2139 Concrete + Deck = 34.3 psf Icr = 53.1 in4/ft Vn/Ω = Mno/Ω= 36.7 kip-in/ft (Icr+Iu)/2 = 69.5 in4/ft Iu = 85.9 in4/ft ϕ Vn = ϕMno= 56.2 kip-in/ft Vertical Load Span (in) 18 Triple 7' - 9" 9' - 3" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 6' - 10" 8' - 5" LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 6 in o.c. 3460 4810 5800 7600 10300 12 in o.c. 3460 4810 5800 7600 10300 18 in o.c. 3460 4810 5800 7600 8790 120 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS BH-36 Composite Deck 4.4 43⁄4" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.162yd3/100ft2 2 Hour Fire Rating Gage 22 20 22 5'-6" ASD, W/Ω LRFD, ϕW L/360 850 1360 - 698 1116 - 2789 2473 2449 2426 36.3 76.06 2725 2438 2416 2395 psf in4/ft 5'-0" 5'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Double 10' - 4" 11' - 7" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 582 931 - 492 787 - 420 672 - 363 580 - 315 505 - 276 442 - 243 390 - 216 345 - 2672 2409 2388 2369 2643 2400 2382 2364 Icr = Iu = 2603 2569 2378 2359 2361 2342 2344 2327 54.7 in4/ft 97.4 in4/ft 2539 2342 2326 2312 2512 2327 2312 2299 2489 2313 2300 2287 Mno/Ω= ϕMno= ASD & LRFD - Superimposed Load, W (psf) LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Triple 10' - 11" 11' - 7" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 192 307 - 2479 2459 2313 2301 2300 2289 2288 2278 34.4 kip-in/ft 52.6 kip-in/ft 172 275 - 154 246 - 2442 2291 2280 2269 2425 2282 2271 2261 Vn/Ω = ϕ Vn = 5'-0" 11'-6" 12'-0" 165 266 165 146 241 146 2482 2466 2315 2305 2302 2293 2291 2283 2.14 kip/ft 4.28 kip/ft 11'-6" 12'-0" 184 346 184 162 314 162 2634 2611 2405 2391 2388 2375 2377 2364 2.14 kip/ft 4.28 kip/ft 11'-6" 12'-0" 201 423 201 177 385 177 2801 2771 2506 2488 2474 2457 2482 2465 2.14 kip/ft 4.28 kip/ft www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 121 ACUSTADEK® LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 6 in o.c. n/a 4990 5980 7780 10480 12 in o.c. n/a 4990 5980 7780 10480 18 in o.c. n/a 4990 5980 7780 8790 D PANEL 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 855 778 713 658 611 570 535 497 419 356 305 264 230 ASD, W/Ω 1711 1555 1426 1316 1219 1056 922 812 719 641 574 516 466 LRFD, ϕW L/360 497 419 356 305 264 230 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3584 3446 3331 3300 3212 3136 3069 3010 2958 2956 2911 2871 2835 PAF Base Steel ≥ .25" 2904 2828 2765 2777 2727 2683 2644 2610 2580 2598 2572 2548 2526 PAF Base Steel ≥ 0.125" 2831 2761 2703 2721 2674 2633 2598 2567 2539 2560 2535 2513 2492 #12 Screw Base Steel ≥ .0385" 2839 2770 2712 2729 2682 2642 2606 2575 2547 2568 2543 2521 2501 Concrete + Deck = 37.9 psf Icr = 83.7 in4/ft Vn/Ω = Mno/Ω= 60.7 kip-in/ft 4 (Icr+Iu)/2 = 98.88 in /ft Iu = 114.0 in4/ft ϕ Vn = ϕMno= 92.9 kip-in/ft 2411 2397 2273 2266 2263 2255 2253 2246 2.14 kip/ft 4.28 kip/ft C PANELS 5'-6" 125 200 - N PANELS 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 547 477 419 371 327 280 242 210 855 778 713 658 611 ASD, W/Ω 1711 1555 1392 1179 1011 875 763 671 594 528 472 424 383 LRFD, ϕW L/360 327 280 242 210 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3251 3144 3055 3022 2954 2896 2844 2799 2759 2752 2718 2687 2660 PAF Base Steel ≥ .25" 2724 2665 2615 2616 2577 2544 2515 2489 2466 2474 2454 2436 2420 PAF Base Steel ≥ 0.125" 2685 2630 2583 2587 2550 2518 2491 2466 2445 2454 2435 2418 2402 #12 Screw Base Steel ≥ .0385" 2658 2605 2561 2566 2531 2501 2474 2451 2430 2440 2422 2405 2390 Concrete + Deck = 37.3 psf Icr = 73.4 in4/ft Vn/Ω = Mno/Ω= 50.7 kip-in/ft (Icr+Iu)/2 = 90.62 in4/ft Iu = 107.8 in4/ft ϕ Vn = ϕMno= 77.6 kip-in/ft 5'-0" 5'-6" 139 222 - B PANELS All Gages Single 8' - 8" 9' - 5" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 855 778 685 579 496 428 373 327 289 257 229 205 184 ASD, W/Ω 1597 1312 1095 927 793 685 597 524 462 411 366 328 295 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2939 2861 2796 2765 2717 2674 2637 2605 2576 2566 2542 2520 2500 PAF Base Steel ≥ .25" 2554 2512 2476 2469 2442 2418 2397 2379 2362 2364 2350 2337 2325 PAF Base Steel ≥ 0.125" 2525 2485 2451 2447 2421 2398 2379 2361 2346 2348 2335 2323 2312 #12 Screw Base Steel ≥ .0385" 2500 2463 2431 2428 2403 2382 2363 2347 2332 2335 2323 2311 2301 Concrete + Deck = 36.6 psf Icr = 61.7 in4/ft Vn/Ω = Mno/Ω= 40.2 kip-in/ft 4 (Icr+Iu)/2 = 81.45 in /ft Iu = 101.2 in4/ft ϕ Vn = ϕMno= 61.5 kip-in/ft Vertical Load Span (in) 16 Gage 18 16 2W PANELS 5'-0" Vertical Load Span (in) 18 Triple 7' - 7" 9' - 1" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 6' - 9" 8' - 4" 3W PANELS GA Single 6' - 5" 7' - 8" GENERAL INFORMATION TABLE OF CONTENTS 4.4 BH-36 Composite Deck 5 11⁄16" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.452yd3/100ft2 3 Hour Fire Rating Gage 22 20 GA 22 Single 6' - 0" 7' - 2" 5'-0" 5'-6" ASD, W/Ω LRFD, ϕW L/360 1097 1817 - 933 1492 - 3396 3081 3056 3034 44.9 128.9 3332 3046 3023 3003 psf in4/ft 5'-0" 5'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Single 8' - 2" 8' - 10" Double 9' - 8" 10' - 10" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 778 1245 - 658 1053 - 563 901 - 486 778 - 423 677 - 371 594 - 327 524 - 290 464 - 3279 3016 2996 2977 3251 3008 2989 2972 Icr = Iu = 3211 2986 2968 2952 89.2 168.7 3177 2966 2950 2935 in4/ft in4/ft 3146 2949 2934 2920 3120 2934 2920 2907 3096 2921 2907 2895 Mno/Ω= ϕMno= ASD & LRFD - Superimposed Load, W (psf) LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Triple 10' - 2" 10' - 11" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 259 414 - 3086 3067 2920 2909 2907 2897 2896 2886 45.9 kip-in/ft 70.2 kip-in/ft 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" ASD & LRFD - Superimposed Load, W (psf) 1097 997 914 844 784 731 646 568 503 448 ASD, W/Ω 2194 1995 1829 1594 1367 1184 1034 909 805 717 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3859 3752 3663 3630 3562 3503 3452 3407 3367 3359 PAF Base Steel ≥ .25" 3331 3272 3223 3224 3185 3152 3122 3096 3074 3082 PAF Base Steel ≥ 0.125" 3293 3237 3191 3194 3158 3126 3098 3074 3052 3062 #12 Screw Base Steel ≥ .0385" 3266 3213 3169 3174 3139 3108 3082 3058 3037 3048 Concrete + Deck = 45.9 psf Icr = 121.2 in4/ft Mno/Ω= 68.3 4 (Icr+Iu)/2 = 153.4 in /ft Iu = 185.6 in4/ft ϕMno= 104.5 Vertical Load Span (in) 231 370 - 208 333 - 3049 2899 2887 2876 3033 2890 2878 2868 Vn/Ω = ϕ Vn = 5'-0" 5'-0" 5'-6" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" ASD & LRFD - Superimposed Load, W (psf) 1097 997 914 844 784 731 686 645 610 546 ASD, W/Ω 2194 1995 1829 1688 1567 1436 1255 1105 980 874 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 4191 4053 3939 3907 3819 3743 3676 3617 3565 3563 PAF Base Steel ≥ .25" 3512 3436 3373 3385 3334 3290 3252 3218 3188 3206 PAF Base Steel ≥ 0.125" 3438 3369 3311 3328 3281 3241 3206 3174 3147 3167 #12 Screw Base Steel ≥ .0385" 3447 3377 3320 3337 3290 3249 3214 3183 3155 3175 Concrete + Deck = 46.5 psf Icr = 138.9 in4/ft Mno/Ω= 82.2 (Icr+Iu)/2 = 167.4 in4/ft Iu = 195.8 in4/ft ϕMno= 125.8 187 300 - 169 271 - 3018 3005 2881 2873 2870 2863 2861 2854 2.74 kip/ft 5.49 kip/ft 11'-6" 12'-0" 225 361 - 204 327 - 3090 3073 2922 2913 2910 2901 2899 2890 2.74 kip/ft 5.49 kip/ft 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 401 642 - 361 577 - 326 521 - 3326 3062 3043 3029 kip-in/ft kip-in/ft 3295 3044 3026 3013 3267 3027 3010 2998 Vn/Ω = ϕ Vn = 295 472 - 268 429 - 3242 3219 3012 2999 2996 2983 2984 2972 2.74 kip/ft 5.49 kip/ft 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 489 783 - 441 705 - 388 637 388 3519 3179 3143 3151 kip-in/ft kip-in/ft 3479 3155 3120 3128 3442 3134 3100 3108 Vn/Ω = ϕ Vn = 340 578 340 299 527 299 3409 3378 3114 3095 3082 3065 3090 3073 2.74 kip/ft 5.49 kip/ft All Gages 16 Gage 18 16 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" ASD & LRFD - Superimposed Load, W (psf) 1097 997 914 778 666 576 502 441 389 346 309 277 249 ASD, W/Ω 2140 1759 1469 1244 1065 921 803 705 623 554 494 443 399 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3547 3469 3404 3373 3324 3282 3245 3212 3183 3174 3150 3128 3108 PAF Base Steel ≥ .25" 3162 3119 3083 3077 3049 3026 3005 2986 2970 2971 2957 2945 2933 PAF Base Steel ≥ 0.125" 3133 3093 3059 3055 3029 3006 2986 2969 2953 2956 2943 2931 2920 #12 Screw Base Steel ≥ .0385" 3108 3070 3038 3036 3011 2990 2971 2954 2940 2943 2930 2919 2909 Concrete + Deck = 45.2 psf Icr = 101.1 in4/ft Vn/Ω = Mno/Ω= 53.8 kip-in/ft (Icr+Iu)/2 = 137.9 in4/ft Iu = 174.7 in4/ft ϕ Vn = ϕMno= 82.3 kip-in/ft Vertical Load Span (in) 18 Triple 7' - 1" 8' - 5" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 6' - 6" 7' - 10" LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 6 in o.c. n/a 5680 6670 8470 11170 12 in o.c. n/a 5680 6670 8470 11170 18 in o.c. n/a 5680 6670 8470 8790 122 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS GENERAL INFORMATION 3W PANELS 2W PANELS B PANELS N PANELS C PANELS D PANEL ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 123 TABLE OF CONTENTS 5.1 NH-32 3-7/8” 4-1/8” 8” 3-7/8” 4-1/8” 8” 3” 3” 2-1/8” 2-1/8” 32” 32” NHN-32 Profile NH-32 Profile 36/5 32/5 Attachment Pattern N Series Embossment Panel Properties Gage Weight 22 20 18 16 w psf 1.97 2.35 3.10 3.86 Compression Gage Area 22 20 18 16 Ae in2/ft 0.272 0.372 0.604 0.871 Base Metal Thickness Yield Strength t in 0.0299 0.0359 0.0478 0.0598 Fy ksi 50 50 50 50 Tensile Strength Area Fu ksi 65 65 65 65 Ag in2/ft 0.569 0.681 0.902 1.123 Effective Section Modulus at Fy Bending Distance to Section N.A. from Section Modulus Bottom Modulus Se+ yb Sein3/ft in in3/ft 0.349 1.37 0.402 0.446 1.41 0.505 0.661 1.48 0.715 0.879 1.54 0.927 Gage 22 20 18 16 124 Condition 1" End 500 Interior 876 End 709 Interior 1240 End 1221 Interior 2133 End 1864 Interior 3260 Web Crippling Constraints Ig in4/ft 0.814 0.968 1.275 1.575 yb in 1.68 1.68 1.69 1.69 Sg in3/ft 0.483 0.576 0.755 0.931 Radius of Gyration r in 1.195 1.193 1.189 1.185 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 1.78 1.76 1.72 1.70 Reactions at Supports (plf) Based on Web Crippling Allowable (Rn/Ω) 1.5" 2" 566 622 973 1056 799 876 1371 1482 1367 1490 2343 2519 2076 2254 3560 3814 h=3.06" Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Moment of Inertia Moment of Inertia Ie+ in4/ft 0.626 0.788 1.121 1.474 I ein4/ft 0.758 0.934 1.275 1.575 Bearing Length of Webs 3" 716 1194 1004 1669 1697 2816 2554 4239 1" 764 1303 1084 1844 1868 3173 2852 4849 r=0.125" Composite and Non-Composite Deck Catalog • February 2016 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 0.689 0.848 1.173 1.508 Factored (ΦRn) 1.5" 2" 866 952 1448 1570 1223 1340 2040 2205 2092 2280 3485 3748 3176 3449 5296 5673 θ=70.7º Iin4/ft 0.776 0.945 1.275 1.575 3" 1095 1776 1536 2482 2597 4189 3907 6305 www.ascsd.com TABLE OF CONTENTS 3-7/8” 4-1/8” 8” 3” 36/5 2-1/8” 32/5 Attachment Pattern 32” Panel Properties Gage Area Ag in2/ft 1.114 1.254 1.406 1.330 1.470 1.622 1.547 1.687 1.839 Effective Section Modulus at Fy Bending Distance to N.A. from Bottom yb in 0.76 0.66 0.62 0.99 0.90 0.81 1.13 1.04 0.96 Section Modulus Sein3/ft 0.808 0.838 0.863 1.057 1.093 1.123 1.306 1.346 1.380 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 1.39 1.24 1.11 1.45 1.33 1.22 1.49 1.39 1.30 Moment of Inertia Ie + in4/ft 1.381 1.480 1.515 1.835 1.972 2.107 2.316 2.495 2.661 Moment of Inertia I ein4/ft 1.454 1.623 1.816 1.839 2.019 2.234 2.218 2.405 2.636 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 1.501 1.612 1.676 1.938 2.087 2.230 2.385 2.572 2.746 Iin4/ft 1.549 1.708 1.877 1.940 2.118 2.314 2.319 2.512 2.729 C PANELS Section Modulus Se+ in3/ft 0.488 0.490 0.522 0.798 0.816 0.810 1.073 1.098 1.119 Radius of Gyration r in 1.250 1.223 1.192 1.269 1.255 1.235 1.277 1.271 1.259 N PANELS 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Area Ae in2/ft 0.547 0.622 0.729 0.784 0.859 0.966 1.057 1.132 1.238 Tensile Strength Fu ksi 65 65 65 65 65 65 65 65 65 B PANELS Compression Base Metal Thickness Yield Strength t Fy in ksi 0.0359 / 0.036 50 0.0359 / 0.047 50 0.0359 / 0.059 50 0.0478 / 0.036 50 0.0478 / 0.047 50 0.0478 / 0.059 50 0.0598 / 0.036 50 0.0598 / 0.047 50 0.0598 / 0.059 50 2W PANELS 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Weight w psf 3.96 4.44 4.96 4.71 5.19 5.71 5.47 5.95 6.47 Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Ig yb Sg in4/ft in in3/ft 1.740 1.07 0.867 1.877 0.96 0.884 1.999 0.87 0.899 2.143 1.19 1.129 2.316 1.09 1.153 2.474 1.00 1.173 2.522 1.27 1.385 2.725 1.18 1.415 2.914 1.10 1.442 3W PANELS NHF-32 Profile Gage GENERAL INFORMATION NHF-32 5.2 D PANEL ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 125 TABLE OF CONTENTS 5.3 NHF-36 Cellular Composite Deck Normal Weight Concrete (145 pcf) Maximum Unshored Spans NHF-36 Cellular Shoring Table Total Slab Depth (in) Volume cy/100sf 5 0.979 6 1.288 6 1/2 1 Hour Fire Rating 1.442 7 1/2 2 Hour Fire Rating 1.751 8 1/4 3 Hour Fire Rating 1.982 Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 145 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 42.0 12' - 5" 14' - 8" 42.4 13' - 0" 15' - 2" 42.9 12' - 10" 15' - 1" 42.6 14' - 4" 16' - 7" 43.1 14' - 7" 17' - 7" 43.6 14' - 9" 18' - 0" 43.3 15' - 1" 18' - 0" 43.8 15' - 4" 18' - 4" 44.3 15' - 6" 18' - 9" 54.0 11' - 4" 13' - 5" 54.5 11' - 10" 13' - 11" 55.0 11' - 9" 13' - 10" 54.7 13' - 6" 15' - 3" 55.2 13' - 9" 16' - 4" 55.7 13' - 11" 16' - 7" 55.4 14' - 2" 16' - 9" 55.8 14' - 5" 17' - 4" 56.4 14' - 8" 17' - 8" 60.1 10' - 10" 12' - 11" 60.6 11' - 4" 13' - 5" 61.1 11' - 3" 13' - 4" 60.7 13' - 2" 14' - 8" 61.2 13' - 5" 15' - 9" 61.7 13' - 7" 16' - 0" 61.4 13' - 10" 16' - 2" 61.9 14' - 1" 16' - 11" 62.4 14' - 4" 17' - 3" 72.2 10' - 1" 12' - 1" 72.6 10' - 7" 12' - 7" 73.2 10' - 6" 12' - 6" 72.8 12' - 8" 13' - 9" 73.3 12' - 10" 14' - 9" 73.8 13' - 0" 15' - 0" 73.5 13' - 3" 15' - 1" 74.0 13' - 6" 16' - 2" 74.5 13' - 8" 16' - 6" 81.2 9' - 7" 11' - 7" 81.7 10' - 1" 12' - 0" 82.2 10' - 0" 11' - 11" 81.9 12' - 3" 13' - 2" 82.4 12' - 4" 14' - 1" 82.9 12' - 5" 14' - 4" 82.6 12' - 11" 14' - 5" 83.0 13' - 2" 15' - 6" 83.5 13' - 4" 15' - 10" Triple 13' - 3" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 12' - 2" 12' - 8" 12' - 6" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 11' - 9" 12' - 2" 12' - 1" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 10' - 11" 11' - 4" 11' - 3" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 10' - 6" 10' - 10" 10' - 10" 12' - 11" 13' - 0" 13' - 1" 13' - 4" 13' - 4" 13' - 4" Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span. 126 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS NHF-36 Cellular Composite Deck 5.3 Light Weight Concrete (110 pcf) Maximum Unshored Spans Volume cy/100sf 5 0.979 1 Hour Fire Rating 1.288 2 Hour Fire Rating 1.365 3 Hour Fire Rating 1.654 D PANEL 7 3/16 C PANELS 6 1/4 N PANELS 6 1.133 Triple 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 2" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 12' - 4" 12' - 10" 12' - 9" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" 13' - 4" B PANELS 5 1/2 ACUSTADEK® Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 110 pcf Light Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 32.7 13' - 9" 15' - 11" 33.2 14' - 5" 16' - 7" 33.7 14' - 3" 16' - 5" 33.4 15' - 4" 18' - 1" 33.8 15' - 6" 18' - 9" 34.4 15' - 9" 19' - 2" 34.0 16' - 0" 19' - 2" 34.5 16' - 3" 19' - 6" 35.0 16' - 6" 19' - 11" 37.3 13' - 1" 15' - 4" 37.8 13' - 8" 15' - 11" 38.3 13' - 7" 15' - 9" 37.9 14' - 10" 17' - 5" 38.4 15' - 1" 18' - 3" 38.9 15' - 3" 18' - 7" 38.6 15' - 7" 18' - 7" 39.1 15' - 10" 19' - 0" 39.6 16' - 0" 19' - 4" 41.9 12' - 7" 14' - 9" 42.3 13' - 1" 15' - 4" 42.9 13' - 0" 15' - 2" 42.5 14' - 5" 16' - 9" 43.0 14' - 8" 17' - 9" 43.5 14' - 10" 18' - 2" 43.2 15' - 2" 18' - 1" 43.7 15' - 5" 18' - 6" 44.2 15' - 7" 18' - 10" 44.2 12' - 4" 14' - 6" 44.6 12' - 10" 15' - 0" 45.2 12' - 9" 14' - 11" 44.8 14' - 3" 16' - 6" 45.3 14' - 6" 17' - 6" 45.8 14' - 8" 17' - 11" 45.5 14' - 11" 17' - 11" 46.0 15' - 2" 18' - 3" 46.5 15' - 5" 18' - 7" 52.8 11' - 6" 13' - 8" 53.2 12' - 0" 14' - 2" 53.7 11' - 11" 14' - 1" 53.4 13' - 8" 15' - 6" 53.9 13' - 11" 16' - 7" 54.4 14' - 1" 16' - 10" 54.1 14' - 4" 17' - 0" 54.6 14' - 7" 17' - 6" 55.1 14' - 9" 17' - 11" 2W PANELS Total Slab Depth (in) 3W PANELS NHF-36 Cellular Shoring Table Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span. www.ascsd.com GENERAL INFORMATION Composite and Non-Composite Deck Catalog • February 2016 127 TABLE OF CONTENTS 5.3 NH-32 Composite Deck 5" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 0.979yd3/100ft2 Gage 22 20 GA 22 Single 9' - 8" 11' - 3" 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 277 443 - 242 387 - 2436 2214 2197 2181 40.3 65.45 2406 2197 2181 2166 psf in4/ft 8'-0" 8'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Single 12' - 8" 13' - 6" 9'-0" 9'-6" 212 340 - 188 300 - 166 266 - 148 237 - 132 211 - 118 189 - 106 170 - 2380 2183 2167 2153 2368 2181 2166 2153 Icr = Iu = 2346 2326 2168 2157 2155 2144 2142 2132 38.1 in4/ft 92.8 in4/ft 2308 2147 2134 2123 2292 2138 2126 2115 2277 2129 2118 2107 Mno/Ω= ϕMno= Double 14' - 11" 16' - 9" 96 153 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern 8'-0" 2272 2259 2130 2122 2119 2112 2109 2102 30.8 kip-in/ft 47.2 kip-in/ft 8'-6" 8'-6" 86 138 - 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 518 456 403 358 320 288 259 235 213 194 ASD, W/Ω 829 729 645 573 513 460 415 375 340 310 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3009 2944 2886 2880 2831 2787 2747 2710 2676 2680 PAF Base Steel ≥ .25" 2532 2495 2462 2478 2449 2423 2399 2378 2358 2374 PAF Base Steel ≥ 0.125" 2480 2446 2416 2434 2407 2383 2362 2342 2323 2341 #12 Screw Base Steel ≥ .0385" 2492 2458 2428 2446 2420 2396 2374 2354 2336 2353 Concrete + Deck = 42.2 psf Icr = 61.6 in4/ft Mno/Ω= 55.2 (Icr+Iu)/2 = 83.94 in4/ft Iu = 106.3 in4/ft ϕMno= 84.5 78 124 - 70 112 - 2247 2115 2105 2096 2235 2109 2099 2090 Vn/Ω = ϕ Vn = 63 101 - 57 91 - 2225 2215 2103 2097 2093 2088 2084 2079 3.12 kip/ft 4.67 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 106 169 - 96 153 - 87 139 - 2330 2163 2151 2140 kip-in/ft kip-in/ft 2315 2154 2142 2132 2301 2146 2135 2125 Vn/Ω = ϕ Vn = 79 126 - 72 115 - 2288 2276 2139 2132 2127 2121 2118 2111 3.12 kip/ft 4.67 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 142 227 - 129 207 - 118 189 - 2482 2253 2237 2225 kip-in/ft kip-in/ft 2461 2241 2225 2214 2441 2229 2214 2203 Vn/Ω = ϕ Vn = 108 172 - 99 158 - 2423 2406 2218 2208 2203 2194 2193 2184 3.12 kip/ft 4.67 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 177 283 - 160 258 160 143 237 143 2650 2356 2324 2336 kip-in/ft kip-in/ft 2622 2339 2308 2321 2597 2324 2294 2306 Vn/Ω = ϕ Vn = 129 217 129 116 200 116 2573 2550 2309 2296 2280 2268 2293 2280 3.12 kip/ft 4.67 kip/ft All Gages 8'-0" Triple 15' - 2" 15' - 11" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 425 373 329 292 261 234 210 190 172 156 ASD, W/Ω 680 597 527 468 417 374 336 303 275 249 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2767 2717 2673 2662 2624 2590 2560 2532 2506 2504 PAF Base Steel ≥ .25" 2396 2368 2343 2349 2327 2308 2290 2274 2259 2267 PAF Base Steel ≥ 0.125" 2369 2343 2319 2326 2306 2287 2270 2255 2241 2250 #12 Screw Base Steel ≥ .0385" 2351 2325 2302 2311 2291 2273 2257 2242 2228 2238 Concrete + Deck = 41.4 psf Icr = 52.9 in4/ft Mno/Ω= 45.8 (Icr+Iu)/2 = 77.02 in4/ft Iu = 101.1 in4/ft ϕMno= 70.1 Vertical Load Span (in) 16 Gage 18 16 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 329 288 253 224 200 178 160 143 129 117 ASD, W/Ω 526 461 406 359 319 285 255 229 207 187 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2543 2507 2474 2462 2435 2411 2389 2369 2350 2346 PAF Base Steel ≥ .25" 2272 2252 2234 2234 2219 2205 2192 2181 2170 2173 PAF Base Steel ≥ 0.125" 2252 2233 2216 2217 2202 2189 2177 2166 2156 2159 #12 Screw Base Steel ≥ .0385" 2235 2216 2200 2202 2188 2176 2165 2154 2145 2148 Concrete + Deck = 40.7 psf Icr = 43.5 in4/ft Mno/Ω= 36.1 4 (Icr+Iu)/2 = 69.59 in /ft Iu = 95.7 in4/ft ϕMno= 55.2 Vertical Load Span (in) 18 Triple 11' - 5" 13' - 0" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 10' - 10" 12' - 7" LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 8 in o.c. 3200 4550 5540 7340 10040 16 in o.c. 3200 4550 5540 7340 9890 24 in o.c. 3200 4550 5540 6590 6590 128 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS NH-32 Composite Deck 5.3 51⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Gage 22 20 22 8'-6" ASD, W/Ω LRFD, ϕW L/360 328 525 - 287 459 - 2853 2666 2652 2638 46.3 86.16 2828 2652 2638 2626 psf in4/ft 8'-0" 8'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = 9'-0" 9'-6" 252 403 - 223 356 - 198 316 - 176 282 - 157 252 - 141 226 - 127 203 - 2805 2639 2626 2614 2797 2639 2627 2616 Icr = Iu = 2778 2628 2617 2606 49.7 122.6 2761 2619 2607 2597 in4/ft in4/ft 2746 2610 2599 2589 2732 2602 2591 2582 2719 2594 2584 2575 Mno/Ω= ϕMno= Double 14' - 3" 16' - 1" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 114 182 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern 8'-0" 8'-6" 84 134 - 2694 2583 2574 2566 2684 2577 2569 2561 Vn/Ω = ϕ Vn = 76 121 - 69 110 - 2675 2667 2572 2567 2564 2559 2557 2552 3.58 kip/ft 5.37 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 126 202 - 114 183 - 104 166 - 2766 2626 2615 2606 kip-in/ft kip-in/ft 2753 2618 2608 2599 2741 2611 2601 2592 Vn/Ω = ϕ Vn = 94 151 - 86 138 - 2730 2719 2604 2598 2595 2589 2586 2581 3.58 kip/ft 5.37 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 169 271 - 154 247 - 141 225 - 2899 2707 2693 2683 kip-in/ft kip-in/ft 2881 2696 2682 2673 2864 2685 2672 2663 Vn/Ω = ϕ Vn = 129 206 - 118 189 - 2848 2833 2676 2667 2663 2655 2654 2646 3.58 kip/ft 5.37 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 193 308 - 177 283 - 3049 2801 2774 2786 kip-in/ft kip-in/ft 3024 2786 2760 2772 3002 2772 2747 2759 Vn/Ω = ϕ Vn = 162 260 - 149 239 - 2981 2961 2759 2747 2735 2723 2747 2735 3.58 kip/ft 5.37 kip/ft www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 129 ACUSTADEK® LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 8 in o.c. 3700 5050 6040 7840 10540 16 in o.c. 3700 5050 6040 7840 9890 24 in o.c. 3700 5050 6040 6590 6590 D PANEL 211 337 - C PANELS 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 616 541 479 426 381 342 309 279 254 231 ASD, W/Ω 985 866 766 682 610 548 494 447 406 369 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3351 3294 3244 3245 3202 3164 3129 3097 3067 3075 PAF Base Steel ≥ .25" 2948 2916 2887 2906 2880 2857 2836 2817 2799 2817 PAF Base Steel ≥ 0.125" 2905 2875 2848 2869 2845 2824 2804 2786 2770 2789 #12 Screw Base Steel ≥ .0385" 2917 2887 2860 2881 2858 2836 2816 2799 2782 2801 Concrete + Deck = 48.2 psf Icr = 80.4 in4/ft Mno/Ω= 65.5 (Icr+Iu)/2 = 110.05 in4/ft Iu = 139.7 in4/ft ϕMno= 100.2 93 148 - N PANELS 8'-6" 103 164 - 2715 2704 2596 2589 2587 2580 2578 2572 36.4 kip-in/ft 55.8 kip-in/ft 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 505 443 391 348 310 278 250 226 205 186 ASD, W/Ω 808 709 626 556 496 445 400 362 327 297 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3139 3096 3058 3052 3020 2991 2964 2940 2918 2919 PAF Base Steel ≥ .25" 2827 2802 2780 2789 2770 2753 2737 2722 2709 2719 PAF Base Steel ≥ 0.125" 2804 2781 2760 2770 2752 2735 2720 2707 2694 2704 #12 Screw Base Steel ≥ .0385" 2788 2766 2746 2757 2739 2723 2709 2696 2684 2694 Concrete + Deck = 47.5 psf Icr = 69.1 in4/ft Mno/Ω= 54.3 (Icr+Iu)/2 = 101.13 in4/ft Iu = 133.2 in4/ft ϕMno= 83.0 8'-0" Triple 14' - 9" 15' - 5" B PANELS All Gages Single 12' - 4" 13' - 1" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 390 342 301 267 237 212 190 171 154 139 ASD, W/Ω 624 547 482 427 379 339 304 273 246 223 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2945 2914 2887 2878 2855 2834 2815 2798 2782 2780 PAF Base Steel ≥ .25" 2717 2700 2684 2686 2673 2661 2650 2639 2630 2634 PAF Base Steel ≥ 0.125" 2700 2683 2669 2672 2659 2647 2637 2627 2619 2623 #12 Screw Base Steel ≥ .0385" 2685 2670 2656 2659 2647 2636 2626 2617 2609 2614 Concrete + Deck = 46.7 psf Icr = 56.7 in4/ft Mno/Ω= 42.7 4 (Icr+Iu)/2 = 91.51 in /ft Iu = 126.3 in4/ft ϕMno= 65.3 Vertical Load Span (in) 16 Gage 18 16 2W PANELS 8'-0" Vertical Load Span (in) 18 Triple 10' - 10" 12' - 5" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 10' - 4" 12' - 0" 3W PANELS GA Single 9' - 3" 10' - 8" Concrete Volume 1.133yd3/100ft2 GENERAL INFORMATION TABLE OF CONTENTS 5.3 NH-32 Composite Deck 6" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.288yd3/100ft2 Gage 22 20 GA 22 Single 8' - 10" 10' - 3" 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 383 613 - 335 536 - All Gages 130 Single 11' - 11" 12' - 8" 9'-0" 9'-6" 294 471 - 260 416 - 231 370 - 206 329 - 184 295 - 165 264 - 148 238 - 3361 3164 3148 3134 3348 3162 3147 3134 Icr = Iu = 3327 3149 3135 3123 63.3 158.6 3307 3138 3125 3113 in4/ft in4/ft 3289 3128 3115 3104 3273 3118 3106 3095 3258 3110 3098 3088 Mno/Ω= ϕMno= Double 13' - 8" 15' - 6" 8'-0" 8'-0" 134 214 - 8'-6" 8'-6" 8'-6" 121 193 - 3253 3240 3111 3103 3100 3092 3089 3083 42.4 kip-in/ft 64.9 kip-in/ft 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 590 518 458 407 363 326 293 265 240 218 ASD, W/Ω 945 830 733 651 582 521 469 424 384 349 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3748 3698 3653 3642 3605 3571 3541 3513 3487 3485 PAF Base Steel ≥ .25" 3377 3349 3324 3330 3308 3289 3271 3254 3240 3248 PAF Base Steel ≥ 0.125" 3350 3323 3300 3307 3287 3268 3251 3236 3222 3230 #12 Screw Base Steel ≥ .0385" 3331 3306 3283 3291 3272 3254 3237 3223 3209 3218 Concrete + Deck = 53.5 psf Icr = 88.3 in4/ft Mno/Ω= 63.3 (Icr+Iu)/2 = 130.01 in4/ft Iu = 171.7 in4/ft ϕMno= 96.9 8'-0" Triple 14' - 1" 15' - 0" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 456 399 352 312 277 248 222 200 181 163 ASD, W/Ω 729 639 563 499 444 397 356 320 289 261 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3524 3488 3455 3443 3416 3392 3370 3350 3331 3327 PAF Base Steel ≥ .25" 3253 3233 3215 3215 3200 3186 3173 3161 3151 3154 PAF Base Steel ≥ 0.125" 3233 3214 3197 3198 3183 3170 3158 3147 3137 3140 #12 Screw Base Steel ≥ .0385" 3215 3197 3181 3183 3169 3157 3145 3135 3126 3129 Concrete + Deck = 52.8 psf Icr = 72.4 in4/ft Mno/Ω= 49.7 4 (Icr+Iu)/2 = 117.76 in /ft Iu = 163.2 in4/ft ϕMno= 76.1 Vertical Load Span (in) 16 Gage 18 16 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3417 3387 PAF Base Steel ≥ .25" 3195 3178 PAF Base Steel ≥ 0.125" 3178 3162 #12 Screw Base Steel ≥ .0385" 3162 3147 Concrete + Deck = 52.4 psf (Icr+Iu)/2 = 110.95 in4/ft Vertical Load Span (in) 18 Triple 10' - 4" 11' - 11" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 9' - 11" 11' - 6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 721 634 561 499 447 401 362 328 298 271 ASD, W/Ω 1153 1014 898 799 715 642 579 525 476 434 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3990 3925 3867 3861 3812 3768 3728 3691 3657 3661 PAF Base Steel ≥ .25" 3513 3476 3443 3459 3430 3404 3380 3359 3339 3355 PAF Base Steel ≥ 0.125" 3461 3427 3397 3415 3388 3364 3342 3322 3304 3322 #12 Screw Base Steel ≥ .0385" 3473 3439 3409 3427 3400 3376 3355 3335 3316 3334 Concrete + Deck = 54.3 psf Icr = 102.7 in4/ft Mno/Ω= 76.5 (Icr+Iu)/2 = 141.35 in4/ft Iu = 180.0 in4/ft ϕMno= 117.0 109 174 - 99 158 - 3227 3096 3086 3076 3216 3089 3080 3071 Vn/Ω = ϕ Vn = 89 143 - 81 129 - 3206 3196 3083 3078 3074 3069 3065 3060 4.07 kip/ft 6.10 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 148 237 - 134 215 - 122 195 - 3311 3144 3131 3121 kip-in/ft kip-in/ft 3296 3135 3123 3113 3282 3127 3115 3105 Vn/Ω = ϕ Vn = 111 178 - 101 162 - 3269 3257 3120 3112 3108 3102 3099 3092 4.07 kip/ft 6.10 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 199 318 - 181 290 - 166 265 - 3462 3234 3218 3206 kip-in/ft kip-in/ft 3441 3222 3206 3195 3422 3210 3195 3184 Vn/Ω = ϕ Vn = 152 243 - 139 223 - 3404 3387 3199 3189 3184 3175 3174 3165 4.07 kip/ft 6.10 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 248 396 - 227 363 - 208 333 - 3631 3337 3305 3317 kip-in/ft kip-in/ft 3603 3320 3289 3301 3577 3304 3275 3287 Vn/Ω = ϕ Vn = 191 306 - 176 281 - 3554 3531 3290 3276 3261 3249 3273 3261 4.07 kip/ft 6.10 kip/ft LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 8 in o.c. 4190 5540 6530 8330 11030 16 in o.c. 4190 5540 6530 8330 9890 24 in o.c. 4190 5540 6530 6590 6590 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS NH-32 Composite Deck 5.3 6 1⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.442yd3/100ft2 1 Hour Fire Rating Gage 22 20 22 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 441 705 - 385 616 - 9'-0" 9'-6" 339 542 - 300 479 - 266 426 - 237 380 - 212 340 - 191 305 - 171 274 - 3851 3654 3639 3625 3839 3652 3638 3624 Icr = Iu = 3817 3640 3626 3613 79.0 201.5 3797 3628 3615 3603 in4/ft in4/ft 3780 3618 3606 3594 3763 3609 3597 3586 3748 3600 3589 3578 Mno/Ω= ϕMno= Double 13' - 2" 14' - 11" 8'-0" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 155 247 - 3743 3730 3601 3593 3590 3583 3580 3573 48.6 kip-in/ft 74.4 kip-in/ft 8'-6" 3718 3586 3576 3567 3707 3580 3570 3561 Vn/Ω = ϕ Vn = 104 166 - 94 150 - 3696 3686 3574 3568 3564 3559 3556 3550 4.58 kip/ft 6.74 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 171 274 - 156 249 - 142 226 - 3801 3634 3622 3611 kip-in/ft kip-in/ft 3786 3626 3614 3603 3772 3618 3606 3596 Vn/Ω = ϕ Vn = 129 206 - 118 188 - 3759 3747 3610 3603 3599 3592 3589 3583 4.58 kip/ft 6.88 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 230 368 - 210 336 - 192 307 - 3953 3725 3708 3696 kip-in/ft kip-in/ft 3932 3712 3696 3685 3912 3700 3685 3674 Vn/Ω = ϕ Vn = 176 282 - 162 259 - 3894 3877 3690 3679 3675 3665 3664 3655 4.58 kip/ft 6.88 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 287 459 - 263 420 - 241 386 - 4121 3827 3795 3807 kip-in/ft kip-in/ft 4094 3810 3780 3792 4068 3795 3765 3777 Vn/Ω = ϕ Vn = 222 355 - 204 327 - 4044 4022 3780 3767 3752 3739 3764 3751 4.58 kip/ft 6.88 kip/ft www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 131 ACUSTADEK® LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 8 in o.c. n/a 6030 7020 8820 11520 16 in o.c. n/a 6030 7020 8820 9890 24 in o.c. n/a 6030 6590 6590 6590 D PANEL 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 832 732 648 577 516 464 419 379 345 314 ASD, W/Ω 1331 1171 1037 923 826 742 670 607 551 502 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 4481 4416 4358 4351 4302 4258 4218 4181 4148 4151 PAF Base Steel ≥ .25" 4003 3966 3933 3949 3920 3894 3871 3849 3829 3845 PAF Base Steel ≥ 0.125" 3951 3917 3887 3905 3879 3855 3833 3813 3795 3812 #12 Screw Base Steel ≥ .0385" 3963 3930 3899 3917 3891 3867 3845 3825 3807 3824 Concrete + Deck = 60.3 psf Icr = 128.7 in4/ft Mno/Ω= 88.1 (Icr+Iu)/2 = 178.27 in4/ft Iu = 227.8 in4/ft ϕMno= 134.7 114 183 - C PANELS 8'-6" 126 202 - N PANELS 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 681 598 528 470 420 376 339 306 278 252 ASD, W/Ω 1089 956 845 751 671 602 542 490 444 404 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 4239 4188 4144 4133 4095 4062 4031 4003 3977 3976 PAF Base Steel ≥ .25" 3868 3839 3814 3820 3799 3779 3761 3745 3730 3738 PAF Base Steel ≥ 0.125" 3841 3814 3790 3798 3777 3758 3742 3726 3712 3721 #12 Screw Base Steel ≥ .0385" 3822 3796 3773 3782 3762 3744 3728 3713 3699 3709 Concrete + Deck = 59.6 psf Icr = 110.5 in4/ft Mno/Ω= 72.8 4 (Icr+Iu)/2 = 164.08 in /ft Iu = 217.7 in4/ft ϕMno= 111.4 8'-0" 140 223 - B PANELS 8'-0" 8'-6" Triple 13' - 7" 14' - 8" 2W PANELS All Gages Single 11' - 8" 12' - 4" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 524 460 405 359 320 286 257 231 209 189 ASD, W/Ω 839 735 648 575 512 458 411 370 334 302 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 4014 3978 3946 3933 3906 3882 3860 3840 3822 3817 PAF Base Steel ≥ .25" 3744 3723 3705 3705 3690 3676 3663 3652 3641 3644 PAF Base Steel ≥ 0.125" 3723 3704 3687 3688 3674 3660 3648 3638 3628 3631 #12 Screw Base Steel ≥ .0385" 3706 3688 3672 3673 3660 3647 3636 3626 3616 3620 Concrete + Deck = 58.8 psf Icr = 90.4 in4/ft Mno/Ω= 57.1 (Icr+Iu)/2 = 148.75 in4/ft Iu = 207.1 in4/ft ϕMno= 87.3 Vertical Load Span (in) 16 Gage 18 16 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3907 3878 PAF Base Steel ≥ .25" 3685 3669 PAF Base Steel ≥ 0.125" 3668 3652 #12 Screw Base Steel ≥ .0385" 3652 3638 Concrete + Deck = 58.4 psf (Icr+Iu)/2 = 140.24 in4/ft Vertical Load Span (in) 18 Triple 9' - 11" 11' - 6" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 9' - 7" 11' - 1" 3W PANELS GA Single 8' - 6" 9' - 10" GENERAL INFORMATION TABLE OF CONTENTS 5.3 NH-32 Composite Deck 7 1⁄2" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.751yd3/100ft2 2 Hour Fire Rating Gage 22 20 GA 22 Single 7' - 11" 9' - 2" 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 561 898 - 491 786 - Single 11' - 1" 11' - 10" 9'-0" 9'-6" 432 692 - 382 612 - 340 544 - 304 486 - 272 435 - 244 391 - 220 352 - 4832 4635 4619 4605 4820 4633 4618 4605 Icr = Iu = 4798 4621 4607 4594 116.8 311.1 4778 4609 4596 4584 in4/ft in4/ft 4760 4599 4587 4575 4744 4590 4578 4567 4729 4581 4570 4559 Mno/Ω= ϕMno= Double 12' - 3" 13' - 11" 8'-0" 8'-0" 199 318 - 8'-6" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 1067 939 832 741 663 597 539 488 444 405 ASD, W/Ω 1708 1503 1331 1186 1062 955 862 781 711 648 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 5462 5396 5339 5332 5283 5239 5199 5162 5129 5132 PAF Base Steel ≥ .25" 4984 4947 4914 4930 4901 4875 4851 4830 4810 4826 PAF Base Steel ≥ 0.125" 4932 4898 4868 4886 4860 4836 4814 4794 4775 4793 #12 Screw Base Steel ≥ .0385" 4944 4910 4880 4898 4872 4848 4826 4806 4788 4805 Concrete + Deck = 72.4 psf Icr = 192.0 in4/ft Mno/Ω= 112.6 (Icr+Iu)/2 = 270.62 in4/ft Iu = 349.2 in4/ft ϕMno= 172.3 163 260 - 148 236 - 4699 4567 4557 4548 4688 4561 4551 4542 Vn/Ω = ϕ Vn = 134 214 - 122 195 - 4677 4667 4555 4549 4545 4540 4536 4531 5.28 kip/ft 7.58 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 220 353 - 200 321 - 183 292 - 4782 4615 4603 4592 kip-in/ft kip-in/ft 4767 4607 4594 4584 4753 4598 4587 4577 Vn/Ω = ϕ Vn = 167 267 - 152 244 - 4740 4728 4591 4584 4580 4573 4570 4564 5.70 kip/ft 8.55 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 296 474 - 271 434 - 248 397 - 4934 4705 4689 4677 kip-in/ft kip-in/ft 4913 4693 4677 4666 4893 4681 4666 4655 Vn/Ω = ϕ Vn = 228 364 - 209 335 - 4875 4858 4670 4660 4656 4646 4645 4636 5.70 kip/ft 8.55 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 370 593 - 340 543 - 312 499 - 5102 4808 4776 4788 kip-in/ft kip-in/ft 5074 4791 4761 4773 5049 4776 4746 4758 Vn/Ω = ϕ Vn = 287 459 - 265 424 - 5025 5002 4761 4748 4733 4720 4745 4732 5.70 kip/ft 8.55 kip/ft All Gages 8'-6" 180 287 - 4724 4711 4582 4574 4571 4564 4561 4554 61.6 kip-in/ft 94.3 kip-in/ft 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 871 765 677 602 538 483 435 394 357 325 ASD, W/Ω 1394 1225 1083 963 861 773 697 630 572 520 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 5219 5169 5125 5114 5076 5043 5012 4984 4958 4956 PAF Base Steel ≥ .25" 4848 4820 4795 4801 4780 4760 4742 4726 4711 4719 PAF Base Steel ≥ 0.125" 4821 4795 4771 4779 4758 4739 4722 4707 4693 4702 #12 Screw Base Steel ≥ .0385" 4803 4777 4754 4763 4743 4725 4709 4694 4680 4690 Concrete + Deck = 71.6 psf Icr = 164.3 in4/ft Mno/Ω= 92.8 4 (Icr+Iu)/2 = 249.42 in /ft Iu = 334.5 in4/ft ϕMno= 142.0 8'-0" Triple 12' - 8" 14' - 0" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 669 587 517 459 409 366 329 296 268 243 ASD, W/Ω 1070 938 828 734 654 586 526 474 428 388 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 4995 4959 4927 4914 4887 4863 4841 4821 4803 4798 PAF Base Steel ≥ .25" 4725 4704 4686 4686 4671 4657 4644 4633 4622 4625 PAF Base Steel ≥ 0.125" 4704 4685 4668 4669 4654 4641 4629 4618 4608 4612 #12 Screw Base Steel ≥ .0385" 4687 4669 4652 4654 4641 4628 4617 4606 4597 4601 Concrete + Deck = 70.9 psf Icr = 133.9 in4/ft Mno/Ω= 72.5 (Icr+Iu)/2 = 226.56 in4/ft Iu = 319.2 in4/ft ϕMno= 110.9 Vertical Load Span (in) 16 Gage 18 16 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 4888 4858 PAF Base Steel ≥ .25" 4666 4650 PAF Base Steel ≥ 0.125" 4649 4633 #12 Screw Base Steel ≥ .0385" 4633 4618 Concrete + Deck = 70.5 psf (Icr+Iu)/2 = 213.93 in4/ft Vertical Load Span (in) 18 Triple 9' - 3" 10' - 8" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 8' - 11" 10' - 4" LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 8 in o.c. n/a 7020 8010 9810 12510 16 in o.c. n/a 7020 8010 9810 9890 24 in o.c. n/a 6590 6590 6590 6590 132 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS NH-32 Composite Deck 5.3 8 1⁄4" Total Slab Depth Normal Weight Concrete (145 pcf) Concrete Volume 1.982yd3/100ft2 3 Hour Fire Rating Gage 22 20 22 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 655 1048 - 574 918 - Double 11' - 9" 13' - 4" 8'-0" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 505 808 - 447 716 - 398 637 - 355 568 - 318 509 - 286 458 - 258 413 - 233 373 - 211 338 - 191 306 - 174 278 - 5568 5370 5355 5341 5555 5369 5354 5341 Icr = Iu = 5534 5356 5342 5330 150.7 417.2 5514 5345 5332 5320 in4/ft in4/ft 5496 5335 5322 5311 5480 5325 5313 5302 5465 5317 5305 5295 Mno/Ω= ϕMno= 5460 5318 5307 5296 71.8 109.8 5447 5310 5299 5290 kip-in/ft kip-in/ft 5434 5303 5293 5283 5423 5296 5287 5277 Vn/Ω = ϕ Vn = ASD & LRFD - Superimposed Load, W (psf) 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 259 414 - 236 377 - 215 344 - 5517 5351 5338 5328 kip-in/ft kip-in/ft 5503 5342 5330 5320 5489 5334 5322 5312 Vn/Ω = ϕ Vn = 196 314 - 180 287 - 5476 5464 5327 5319 5315 5308 5306 5299 6.61 kip/ft 9.91 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 349 558 - 319 510 - 292 468 - 5669 5441 5424 5413 kip-in/ft kip-in/ft 5648 5429 5413 5401 5629 5417 5401 5391 Vn/Ω = ϕ Vn = 269 430 - 247 395 - 5611 5594 5406 5396 5391 5382 5381 5372 6.61 kip/ft 9.91 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 436 698 - 400 640 - 368 588 - 5838 5544 5512 5524 kip-in/ft kip-in/ft 5810 5527 5496 5508 5784 5511 5482 5494 Vn/Ω = ϕ Vn = 339 542 - 312 500 - 5760 5738 5497 5483 5468 5456 5480 5468 6.61 kip/ft 9.91 kip/ft www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 133 ACUSTADEK® LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 8 in o.c. n/a 7760 8750 10550 13250 16 in o.c. n/a 7760 8750 9890 9890 24 in o.c. n/a 6590 6590 6590 6590 D PANEL 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 1252 1102 977 870 779 701 634 574 523 477 ASD, W/Ω 2004 1764 1563 1392 1247 1122 1014 919 836 763 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 6197 6132 6074 6068 6019 5975 5934 5898 5864 5868 PAF Base Steel ≥ .25" 5720 5683 5650 5665 5637 5611 5587 5566 5546 5562 PAF Base Steel ≥ 0.125" 5668 5634 5604 5622 5595 5571 5549 5529 5511 5529 #12 Screw Base Steel ≥ .0385" 5680 5646 5616 5634 5607 5583 5562 5542 5523 5541 Concrete + Deck = 81.5 psf Icr = 249.6 in4/ft Mno/Ω= 131.9 (Icr+Iu)/2 = 357.70 in4/ft Iu = 465.8 in4/ft ϕMno= 201.7 5413 5403 5290 5285 5281 5275 5272 5267 5.73 kip/ft 8.26 kip/ft C PANELS 8'-6" 144 230 - N PANELS 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 463 420 382 1020 897 794 706 631 567 511 ASD, W/Ω 1633 1435 1270 1130 1010 907 818 740 672 612 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 5955 5905 5860 5849 5812 5778 5748 5719 5694 5692 PAF Base Steel ≥ .25" 5584 5556 5531 5537 5515 5496 5478 5461 5446 5455 PAF Base Steel ≥ 0.125" 5557 5530 5507 5514 5494 5475 5458 5443 5428 5437 #12 Screw Base Steel ≥ .0385" 5538 5513 5490 5498 5479 5461 5444 5430 5416 5425 Concrete + Deck = 80.7 psf Icr = 213.1 in4/ft Mno/Ω= 108.5 4 (Icr+Iu)/2 = 330.07 in /ft Iu = 447.0 in4/ft ϕMno= 166.0 8'-0" 8'-6" 158 253 - B PANELS 8'-0" 8'-6" Triple 12' - 2" 13' - 8" 2W PANELS All Gages Single 10' - 8" 11' - 6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 782 686 605 537 479 429 385 347 314 285 ASD, W/Ω 1251 1097 968 859 766 686 617 556 503 456 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 5731 5694 5662 5650 5623 5599 5577 5557 5538 5534 PAF Base Steel ≥ .25" 5460 5440 5422 5422 5407 5393 5380 5368 5358 5360 PAF Base Steel ≥ 0.125" 5440 5421 5404 5405 5390 5377 5365 5354 5344 5347 #12 Screw Base Steel ≥ .0385" 5422 5404 5388 5390 5376 5364 5352 5342 5333 5336 Concrete + Deck = 79.9 psf Icr = 173.1 in4/ft Mno/Ω= 84.5 (Icr+Iu)/2 = 300.31 in4/ft Iu = 427.5 in4/ft ϕMno= 129.3 Vertical Load Span (in) 16 Gage 18 16 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 5624 5594 PAF Base Steel ≥ .25" 5402 5385 PAF Base Steel ≥ 0.125" 5385 5369 #12 Screw Base Steel ≥ .0385" 5369 5354 Concrete + Deck = 79.6 psf (Icr+Iu)/2 = 283.94 in4/ft Vertical Load Span (in) 18 Triple 8' - 10" 10' - 2" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 8' - 7" 9' - 11" 3W PANELS GA Single 7' - 7" 8' - 9" GENERAL INFORMATION TABLE OF CONTENTS 5.3 NH-32 Composite Deck 5" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 0.979yd3/100ft2 Gage 22 20 GA 22 Single 10' - 8" 12' - 5" 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 269 430 - 236 377 - 1780 1558 1541 1525 31.0 76.03 1751 1542 1526 1511 psf in4/ft 8'-0" 8'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = Single 13' - 7" 14' - 4" 9'-0" 9'-6" 208 332 - 184 294 - 164 262 - 146 234 - 131 210 - 118 189 - 107 171 - 1724 1527 1512 1498 1712 1525 1511 1497 Icr = Iu = 1690 1513 1499 1486 51.6 100.4 1671 1502 1488 1476 in4/ft in4/ft 1653 1491 1479 1467 1636 1482 1470 1459 1621 1473 1462 1451 Mno/Ω= ϕMno= Double 16' - 3" 17' - 11" 96 154 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern 8'-0" 1616 1603 1474 1467 1463 1456 1453 1446 29.3 kip-in/ft 44.9 kip-in/ft 8'-6" 8'-6" 87 140 - 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 491 432 383 341 306 268 233 204 179 159 ASD, W/Ω 786 692 613 546 489 440 397 360 327 299 LRFD, ϕW L/360 268 233 204 179 159 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2364 2299 2241 2234 2185 2141 2101 2064 2031 2034 PAF Base Steel ≥ .25" 1886 1849 1816 1832 1803 1777 1754 1732 1712 1728 PAF Base Steel ≥ 0.125" 1834 1800 1770 1788 1762 1738 1716 1696 1678 1695 #12 Screw Base Steel ≥ .0385" 1843 1809 1778 1797 1770 1746 1724 1704 1686 1703 Concrete + Deck = 32.9 psf Icr = 81.3 in4/ft Mno/Ω= 51.8 (Icr+Iu)/2 = 100.33 in4/ft Iu = 119.4 in4/ft ϕMno= 79.3 79 127 - 72 115 - 1591 1460 1449 1440 1580 1453 1443 1434 Vn/Ω = ϕ Vn = 66 105 - 60 96 - 1569 1560 1447 1441 1437 1432 1429 1424 2.34 kip/ft 4.67 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 105 169 - 96 154 - 88 140 - 1676 1510 1497 1486 kip-in/ft kip-in/ft 1661 1501 1489 1478 1647 1493 1481 1471 Vn/Ω = ϕ Vn = 80 128 - 73 117 - 1634 1622 1485 1478 1474 1467 1464 1458 2.34 kip/ft 4.67 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 128 222 128 115 203 115 103 186 103 1832 1604 1587 1576 kip-in/ft kip-in/ft 1811 1591 1575 1564 1791 1580 1564 1553 Vn/Ω = ϕ Vn = 93 171 93 84 157 84 1773 1756 1569 1559 1554 1544 1543 1534 2.34 kip/ft 4.67 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 141 273 141 126 250 126 113 230 113 2004 1710 1678 1687 kip-in/ft kip-in/ft 1977 1694 1663 1671 1951 1678 1648 1656 Vn/Ω = ϕ Vn = 102 212 102 92 195 92 1927 1905 1663 1650 1635 1622 1643 1630 2.34 kip/ft 4.67 kip/ft All Gages 8'-0" Triple 16' - 3" 17' - 0" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 406 357 316 281 251 225 203 184 163 144 ASD, W/Ω 649 571 505 449 402 361 325 294 267 243 LRFD, ϕW L/360 163 144 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2118 2068 2023 2012 1975 1941 1910 1882 1856 1855 PAF Base Steel ≥ .25" 1747 1718 1693 1700 1678 1658 1640 1624 1609 1617 PAF Base Steel ≥ 0.125" 1720 1693 1669 1677 1656 1638 1621 1605 1591 1600 #12 Screw Base Steel ≥ .0385" 1701 1675 1653 1661 1641 1623 1607 1592 1579 1588 Concrete + Deck = 32.2 psf Icr = 70.5 in4/ft Mno/Ω= 43.2 4 (Icr+Iu)/2 = 91.29 in /ft Iu = 112.1 in4/ft ϕMno= 66.0 Vertical Load Span (in) 16 Gage 18 16 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 317 278 246 218 195 174 157 141 128 116 ASD, W/Ω 508 445 393 349 311 279 251 226 205 186 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 1889 1853 1821 1808 1782 1757 1735 1715 1697 1692 PAF Base Steel ≥ .25" 1619 1599 1580 1581 1565 1551 1539 1527 1516 1519 PAF Base Steel ≥ 0.125" 1598 1579 1562 1563 1549 1536 1524 1513 1503 1506 #12 Screw Base Steel ≥ .0385" 1581 1563 1547 1549 1535 1522 1511 1501 1491 1495 Concrete + Deck = 31.4 psf Icr = 58.5 in4/ft Mno/Ω= 34.2 (Icr+Iu)/2 = 81.52 in4/ft Iu = 104.5 in4/ft ϕMno= 52.3 Vertical Load Span (in) 18 Triple 12' - 7" 14' - 2" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 11' - 9" 13' - 9" LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 8 in o.c. 2720 4070 5060 6860 9560 16 in o.c. 2720 4070 5060 6860 9560 24 in o.c. 2720 4070 5060 6590 6590 134 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS NH-32 Composite Deck 5.3 5 1⁄2" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.982yd3/100ft2 3 Hour Fire Rating Gage 22 20 22 8'-6" ASD, W/Ω LRFD, ϕW L/360 319 510 - 280 447 - 2104 1882 1865 1849 35.6 99.79 2075 1866 1850 1835 psf in4/ft 8'-0" 8'-6" Arc Spot Weld 1/2" Effective Dia PAF Base Steel ≥ .25" PAF Base Steel ≥ 0.125" #12 Screw Base Steel ≥ .0385" Concrete + Deck = (Icr+Iu)/2 = 9'-0" 9'-6" 246 394 - 218 350 - 195 311 - 174 278 - 156 250 - 141 225 - 127 203 - 2048 1851 1836 1822 2036 1849 1835 1821 Icr = Iu = 2014 1837 1823 1810 67.3 132.2 1995 1826 1812 1800 in4/ft in4/ft 1977 1815 1803 1791 1960 1806 1794 1783 1945 1798 1786 1775 Mno/Ω= ϕMno= Double 15' - 7" 17' - 4" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 115 184 - LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern 8'-0" 8'-6" 86 138 - 1915 1784 1773 1764 1904 1777 1767 1758 Vn/Ω = ϕ Vn = 79 126 - 72 115 - 1893 1884 1771 1765 1762 1756 1753 1748 2.68 kip/ft 5.31 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 126 201 - 115 184 - 105 168 - 2000 1834 1821 1810 kip-in/ft kip-in/ft 1985 1825 1813 1802 1971 1817 1805 1795 Vn/Ω = ϕ Vn = 96 153 - 88 140 - 1958 1946 1809 1802 1798 1791 1788 1782 2.68 kip/ft 5.37 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 165 265 - 150 242 150 134 222 134 2156 1928 1911 1900 kip-in/ft kip-in/ft 2135 1915 1899 1888 2116 1904 1888 1877 Vn/Ω = ϕ Vn = 121 204 121 109 188 109 2097 2080 1893 1883 1878 1868 1867 1858 2.68 kip/ft 5.37 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 164 299 164 147 274 147 2328 2034 2002 2011 kip-in/ft kip-in/ft 2301 2018 1987 1995 2275 2002 1972 1981 Vn/Ω = ϕ Vn = 133 253 133 120 233 120 2251 2229 1988 1974 1959 1946 1967 1954 2.68 kip/ft 5.37 kip/ft www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 135 ACUSTADEK® LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 8 in o.c. 3090 4440 5430 7230 9930 16 in o.c. 3090 4440 5430 7230 9890 24 in o.c. 3090 4440 5430 6590 6590 D PANEL 184 326 184 C PANELS 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 583 514 455 406 363 327 295 266 234 207 ASD, W/Ω 933 822 728 649 581 523 472 428 390 356 LRFD, ϕW L/360 266 234 207 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2688 2623 2565 2558 2509 2465 2425 2388 2355 2358 PAF Base Steel ≥ .25" 2210 2173 2140 2156 2127 2101 2078 2056 2036 2053 PAF Base Steel ≥ 0.125" 2158 2124 2094 2112 2086 2062 2040 2020 2002 2019 #12 Screw Base Steel ≥ .0385" 2167 2133 2102 2121 2094 2070 2048 2028 2010 2027 Concrete + Deck = 37.5 psf Icr = 105.8 in4/ft Mno/Ω= 61.4 (Icr+Iu)/2 = 130.91 in4/ft Iu = 156.1 in4/ft ϕMno= 93.9 95 152 - N PANELS 8'-6" 104 167 - 1940 1927 1798 1791 1787 1780 1777 1770 34.7 kip-in/ft 53.1 kip-in/ft 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 482 424 375 334 299 268 242 219 199 181 ASD, W/Ω 771 678 600 534 478 429 387 350 318 290 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2442 2392 2347 2336 2299 2265 2234 2206 2180 2179 PAF Base Steel ≥ .25" 2071 2042 2017 2024 2002 1982 1964 1948 1933 1941 PAF Base Steel ≥ 0.125" 2044 2017 1993 2001 1980 1962 1945 1929 1915 1924 #12 Screw Base Steel ≥ .0385" 2025 1999 1977 1985 1965 1947 1931 1916 1903 1912 Concrete + Deck = 36.8 psf Icr = 91.8 in4/ft Mno/Ω= 51.2 4 (Icr+Iu)/2 = 119.40 in /ft Iu = 147.0 in4/ft ϕMno= 78.3 8'-0" Triple 15' - 9" 16' - 6" B PANELS All Gages Single 13' - 2" 13' - 11" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 376 330 292 259 231 207 186 168 152 138 ASD, W/Ω 602 529 467 415 370 332 298 269 244 221 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2213 2177 2145 2132 2106 2081 2059 2039 2021 2016 PAF Base Steel ≥ .25" 1943 1923 1904 1905 1889 1875 1863 1851 1841 1843 PAF Base Steel ≥ 0.125" 1922 1903 1886 1887 1873 1860 1848 1837 1827 1830 #12 Screw Base Steel ≥ .0385" 1905 1887 1871 1873 1859 1846 1835 1825 1815 1819 Concrete + Deck = 36.0 psf Icr = 76.3 in4/ft Mno/Ω= 40.5 (Icr+Iu)/2 = 106.87 in4/ft Iu = 137.4 in4/ft ϕMno= 62.0 Vertical Load Span (in) 16 Gage 18 16 2W PANELS 8'-0" Vertical Load Span (in) 18 Triple 12' - 0" 13' - 8" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 11' - 4" 13' - 2" 3W PANELS GA Single 10' - 2" 11' - 10" GENERAL INFORMATION TABLE OF CONTENTS 5.3 NH-32 Composite Deck 6" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.288yd3/100ft2 Gage 22 20 GA 22 Single 9' - 9" 11' - 4" 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 373 596 - 327 523 - Single 12' - 9" 13' - 7" 9'-0" 9'-6" 288 461 - 256 409 - 228 364 - 204 326 - 183 293 - 165 264 - 149 238 - 2372 2175 2160 2146 2360 2173 2159 2145 Icr = Iu = 2338 2161 2147 2134 85.9 170.6 2319 2150 2137 2124 in4/ft in4/ft 2301 2139 2127 2115 2284 2130 2118 2107 2270 2122 2110 2100 Mno/Ω= ϕMno= Double 15' - 0" 16' - 10" 8'-0" 8'-0" 135 216 - 8'-6" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 684 602 534 476 426 384 347 315 286 261 ASD, W/Ω 1094 963 854 761 682 614 555 503 458 418 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3012 2947 2889 2882 2834 2789 2749 2712 2679 2682 PAF Base Steel ≥ .25" 2534 2497 2464 2480 2451 2425 2402 2380 2360 2377 PAF Base Steel ≥ 0.125" 2482 2448 2418 2436 2410 2386 2364 2344 2326 2343 #12 Screw Base Steel ≥ .0385" 2491 2457 2427 2445 2418 2394 2372 2352 2334 2351 Concrete + Deck = 42.1 psf Icr = 135.1 in4/ft Mno/Ω= 71.8 (Icr+Iu)/2 = 167.71 in4/ft Iu = 200.3 in4/ft ϕMno= 109.9 111 178 - 101 162 - 2239 2108 2097 2088 2228 2101 2091 2082 Vn/Ω = ϕ Vn = 92 148 - 84 135 - 2217 2208 2095 2089 2086 2080 2077 2072 3.05 kip/ft 5.59 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 148 236 - 135 216 - 123 197 - 2324 2158 2145 2134 kip-in/ft kip-in/ft 2309 2149 2137 2126 2295 2141 2129 2119 Vn/Ω = ϕ Vn = 113 181 - 103 166 - 2282 2270 2133 2126 2122 2115 2112 2106 3.05 kip/ft 6.10 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 194 311 - 178 285 - 163 261 - 2480 2252 2235 2224 kip-in/ft kip-in/ft 2459 2239 2223 2212 2440 2228 2212 2201 Vn/Ω = ϕ Vn = 150 240 - 138 221 - 2421 2405 2217 2207 2202 2192 2192 2182 3.05 kip/ft 6.10 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 236 383 236 211 351 211 189 323 189 2652 2358 2327 2335 kip-in/ft kip-in/ft 2625 2342 2311 2319 2599 2326 2296 2305 Vn/Ω = ϕ Vn = 170 298 170 154 275 154 2575 2553 2312 2298 2283 2270 2291 2278 3.05 kip/ft 6.10 kip/ft All Gages 8'-6" 122 196 - 2264 2251 2122 2115 2111 2104 2101 2094 40.4 kip-in/ft 61.9 kip-in/ft 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 564 496 439 391 350 315 284 257 234 213 ASD, W/Ω 903 794 703 626 560 503 454 411 374 341 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2766 2716 2671 2660 2623 2589 2558 2530 2504 2503 PAF Base Steel ≥ .25" 2395 2366 2341 2348 2326 2306 2288 2272 2257 2265 PAF Base Steel ≥ 0.125" 2368 2341 2317 2325 2304 2286 2269 2253 2239 2248 #12 Screw Base Steel ≥ .0385" 2349 2323 2301 2309 2289 2271 2255 2240 2227 2236 Concrete + Deck = 41.3 psf Icr = 117.3 in4/ft Mno/Ω= 59.8 (Icr+Iu)/2 = 153.15 in4/ft Iu = 189.0 in4/ft ϕMno= 91.4 8'-0" Triple 15' - 3" 16' - 1" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 440 386 341 303 271 243 219 197 179 162 ASD, W/Ω 704 618 546 485 433 388 350 316 286 260 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2537 2501 2469 2456 2430 2405 2383 2363 2345 2340 PAF Base Steel ≥ .25" 2267 2247 2229 2229 2213 2199 2187 2175 2165 2167 PAF Base Steel ≥ 0.125" 2246 2227 2210 2211 2197 2184 2172 2161 2151 2154 #12 Screw Base Steel ≥ .0385" 2229 2211 2195 2197 2183 2170 2159 2149 2139 2143 Concrete + Deck = 40.6 psf Icr = 97.5 in4/ft Mno/Ω= 47.3 (Icr+Iu)/2 = 137.24 in4/ft Iu = 177.0 in4/ft ϕMno= 72.3 Vertical Load Span (in) 16 Gage 18 16 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2428 2399 PAF Base Steel ≥ .25" 2206 2190 PAF Base Steel ≥ 0.125" 2189 2174 #12 Screw Base Steel ≥ .0385" 2173 2159 Concrete + Deck = 40.2 psf (Icr+Iu)/2 = 128.25 in4/ft Vertical Load Span (in) 18 Triple 11' - 6" 13' - 1" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 10' - 11" 12' - 8" LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 8 in o.c. 3460 4810 5800 7600 10300 16 in o.c. 3460 4810 5800 7600 9890 24 in o.c. 3460 4810 5800 6590 6590 136 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS NH-32 Composite Deck 5.3 6 1⁄4" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.369yd3/100ft2 2 Hour Fire Rating Gage 22 20 22 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 401 641 - 351 562 - 9'-0" 9'-6" 310 496 - 275 440 - 245 392 - 219 351 - 197 315 - 177 284 - 160 257 - 2534 2337 2322 2308 2522 2335 2321 2307 Icr = Iu = 2500 2323 2309 2296 96.3 192.4 2481 2312 2299 2286 in4/ft in4/ft 2463 2301 2289 2277 2447 2292 2280 2269 2432 2284 2272 2262 Mno/Ω= ϕMno= Double 14' - 9" 16' - 8" 8'-0" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 145 233 - 2426 2413 2284 2277 2273 2266 2263 2256 43.4 kip-in/ft 66.4 kip-in/ft 8'-6" 2401 2270 2259 2250 2390 2263 2253 2244 Vn/Ω = ϕ Vn = 100 160 - 91 146 - 2380 2370 2257 2251 2248 2242 2239 2234 3.24 kip/ft 5.73 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 159 255 - 145 233 - 133 213 - 2486 2320 2307 2296 kip-in/ft kip-in/ft 2471 2311 2299 2289 2457 2303 2291 2281 Vn/Ω = ϕ Vn = 122 195 - 112 179 - 2445 2432 2295 2288 2284 2277 2274 2268 3.24 kip/ft 6.48 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 210 336 - 192 307 - 176 282 - 2642 2414 2397 2386 kip-in/ft kip-in/ft 2621 2401 2385 2374 2602 2390 2374 2363 Vn/Ω = ϕ Vn = 162 259 - 149 239 - 2583 2567 2379 2369 2364 2354 2354 2344 3.24 kip/ft 6.48 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 258 413 - 237 379 237 212 349 212 2814 2520 2489 2497 kip-in/ft kip-in/ft 2787 2504 2473 2481 2761 2488 2458 2467 Vn/Ω = ϕ Vn = 191 322 191 173 297 173 2737 2715 2474 2460 2445 2432 2453 2440 3.24 kip/ft 6.48 kip/ft www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 137 ACUSTADEK® LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 8 in o.c. n/a 4990 5980 7780 10480 16 in o.c. n/a 4990 5980 7780 9890 24 in o.c. n/a 4990 5980 6590 6590 D PANEL 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 736 648 575 512 459 413 374 339 309 282 ASD, W/Ω 1178 1037 920 820 735 661 598 543 494 451 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3174 3109 3051 3044 2996 2951 2911 2875 2841 2844 PAF Base Steel ≥ .25" 2696 2659 2626 2642 2613 2587 2564 2542 2522 2539 PAF Base Steel ≥ 0.125" 2644 2610 2580 2598 2572 2548 2526 2506 2488 2505 #12 Screw Base Steel ≥ .0385" 2653 2619 2589 2607 2580 2556 2534 2514 2496 2514 Concrete + Deck = 44.4 psf Icr = 151.7 in4/ft Mno/Ω= 77.3 (Icr+Iu)/2 = 188.57 in4/ft Iu = 225.5 in4/ft ϕMno= 118.2 109 175 - C PANELS 8'-6" 120 192 - N PANELS 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 607 534 473 421 377 339 306 277 252 229 ASD, W/Ω 972 855 757 674 603 542 489 443 403 367 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2928 2878 2833 2822 2785 2751 2720 2692 2666 2665 PAF Base Steel ≥ .25" 2557 2529 2503 2510 2488 2468 2450 2434 2419 2427 PAF Base Steel ≥ 0.125" 2530 2503 2479 2487 2466 2448 2431 2415 2401 2410 #12 Screw Base Steel ≥ .0385" 2511 2485 2463 2471 2451 2433 2417 2402 2389 2398 Concrete + Deck = 43.6 psf Icr = 131.7 in4/ft Mno/Ω= 64.3 (Icr+Iu)/2 = 172.28 in4/ft Iu = 212.9 in4/ft ϕMno= 98.3 8'-0" 132 211 - B PANELS 8'-0" 8'-6" Triple 15' - 1" 15' - 10" 2W PANELS All Gages Single 12' - 7" 13' - 4" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 473 416 367 326 291 261 235 213 193 175 ASD, W/Ω 758 665 588 522 466 418 376 340 308 280 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2700 2663 2631 2618 2592 2567 2545 2525 2507 2502 PAF Base Steel ≥ .25" 2429 2409 2391 2391 2375 2361 2349 2337 2327 2329 PAF Base Steel ≥ 0.125" 2408 2389 2372 2373 2359 2346 2334 2323 2313 2316 #12 Screw Base Steel ≥ .0385" 2391 2373 2357 2359 2345 2332 2321 2311 2301 2305 Concrete + Deck = 42.9 psf Icr = 109.3 in4/ft Mno/Ω= 50.8 (Icr+Iu)/2 = 154.45 in4/ft Iu = 199.6 in4/ft ϕMno= 77.7 Vertical Load Span (in) 16 Gage 18 16 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 2590 2561 PAF Base Steel ≥ .25" 2369 2352 PAF Base Steel ≥ 0.125" 2351 2336 #12 Screw Base Steel ≥ .0385" 2335 2321 Concrete + Deck = 42.5 psf (Icr+Iu)/2 = 144.38 in4/ft Vertical Load Span (in) 18 Triple 11' - 3" 12' - 11" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 10' - 9" 12' - 6" 3W PANELS GA Single 9' - 7" 11' - 2" GENERAL INFORMATION TABLE OF CONTENTS 5.3 NH-32 Composite Deck 7 3⁄16" Total Slab Depth Light Weight Concrete (110 pcf) Concrete Volume 1.654yd3/100ft2 3 Hour Fire Rating Gage 22 20 GA 22 Single 9' - 0" 10' - 5" 8'-0" 8'-6" ASD, W/Ω LRFD, ϕW L/360 511 817 - 448 717 - Single 12' - 1" 12' - 10" 9'-0" 9'-6" 395 633 - 351 562 - 313 501 - 280 449 - 252 403 - 227 364 - 206 329 - 3142 2945 2929 2915 3130 2943 2928 2915 Icr = Iu = 3108 2931 2917 2904 142.0 292.2 3088 2919 2906 2894 in4/ft in4/ft 3070 2909 2897 2885 3054 2900 2888 2877 3039 2891 2880 2869 Mno/Ω= ϕMno= Double 13' - 10" 15' - 8" 8'-0" 8'-0" 187 298 - 8'-6" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 946 833 739 659 591 532 481 437 398 364 ASD, W/Ω 1513 1333 1182 1054 945 852 770 699 637 582 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3782 3716 3659 3652 3603 3559 3519 3482 3448 3452 PAF Base Steel ≥ .25" 3304 3267 3234 3250 3221 3195 3171 3150 3130 3146 PAF Base Steel ≥ 0.125" 3252 3218 3188 3206 3179 3155 3134 3114 3095 3113 #12 Screw Base Steel ≥ .0385" 3260 3226 3196 3214 3188 3164 3142 3122 3104 3121 Concrete + Deck = 53.0 psf Icr = 225.3 in4/ft Mno/Ω= 98.9 (Icr+Iu)/2 = 282.61 in4/ft Iu = 339.9 in4/ft ϕMno= 151.3 154 247 - 141 226 - 3009 2877 2867 2858 2998 2871 2861 2852 Vn/Ω = ϕ Vn = 129 206 - 118 189 - 2987 2977 2865 2859 2855 2850 2846 2841 4.00 kip/ft 6.30 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 205 328 - 187 300 - 171 274 - 3094 2927 2915 2904 kip-in/ft kip-in/ft 3079 2919 2906 2896 3065 2910 2899 2889 Vn/Ω = ϕ Vn = 157 251 - 144 231 - 3052 3040 2903 2896 2892 2885 2882 2876 4.00 kip/ft 8.01 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 270 433 - 248 397 - 228 364 - 3250 3021 3005 2993 kip-in/ft kip-in/ft 3229 3009 2993 2982 3209 2997 2982 2971 Vn/Ω = ϕ Vn = 210 335 - 193 309 - 3191 3174 2986 2976 2971 2962 2961 2952 4.00 kip/ft 8.01 kip/ft 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 333 533 - 306 490 - 282 451 - 3422 3128 3096 3104 kip-in/ft kip-in/ft 3394 3111 3081 3089 3369 3096 3066 3074 Vn/Ω = ϕ Vn = 260 416 - 241 385 - 3345 3322 3081 3068 3053 3040 3061 3048 4.00 kip/ft 8.01 kip/ft All Gages 8'-6" 170 271 - 3034 3021 2892 2884 2881 2874 2871 2864 55.1 kip-in/ft 84.3 kip-in/ft 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 778 685 607 540 484 435 393 356 324 296 ASD, W/Ω 1245 1096 971 865 774 697 629 570 519 473 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3535 3485 3441 3430 3392 3359 3328 3300 3274 3272 PAF Base Steel ≥ .25" 3164 3136 3111 3117 3096 3076 3058 3042 3027 3035 PAF Base Steel ≥ 0.125" 3137 3111 3087 3094 3074 3055 3038 3023 3009 3018 #12 Screw Base Steel ≥ .0385" 3119 3093 3070 3079 3059 3041 3025 3010 2996 3006 Concrete + Deck = 52.2 psf Icr = 195.2 in4/ft Mno/Ω= 82.1 4 (Icr+Iu)/2 = 258.46 in /ft Iu = 321.7 in4/ft ϕMno= 125.6 8'-0" Triple 14' - 4" 15' - 2" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" ASD & LRFD - Superimposed Load, W (psf) 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" ASD & LRFD - Superimposed Load, W (psf) 604 531 470 417 373 335 302 273 247 225 ASD, W/Ω 967 850 751 668 597 536 482 436 396 360 LRFD, ϕW L/360 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3307 3271 3239 3226 3199 3175 3153 3133 3115 3110 PAF Base Steel ≥ .25" 3037 3016 2998 2998 2983 2969 2956 2945 2934 2937 PAF Base Steel ≥ 0.125" 3016 2997 2980 2981 2966 2953 2941 2930 2920 2924 #12 Screw Base Steel ≥ .0385" 2999 2981 2964 2966 2953 2940 2929 2918 2909 2913 Concrete + Deck = 51.5 psf Icr = 161.4 in4/ft Mno/Ω= 64.6 (Icr+Iu)/2 = 232 in4/ft Iu = 302.6 in4/ft ϕMno= 98.8 Vertical Load Span (in) 16 Gage 18 16 LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern Arc Spot Weld 1/2" Effective Dia 3198 3168 PAF Base Steel ≥ .25" 2976 2960 PAF Base Steel ≥ 0.125" 2959 2943 #12 Screw Base Steel ≥ .0385" 2943 2928 Concrete + Deck = 51.1 psf (Icr+Iu)/2 = 217.11 in4/ft Vertical Load Span (in) 18 Triple 10' - 6" 12' - 1" Vertical Load Span (in) Vertical Load Span (in) 20 Maximum Unshored Span (in) Double 10' - 1" 11' - 9" LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width 6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6 3/4" Welded Shear Studs As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft 8 in o.c. n/a 5680 6670 8470 11170 16 in o.c. n/a 5680 6670 8470 9890 24 in o.c. n/a 5680 6590 6590 6590 138 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS GENERAL INFORMATION 3W PANELS 2W PANELS B PANELS N PANELS C PANELS D PANEL ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 139 TABLE OF CONTENTS 6.1 C0.9-32 7/8” 2-11/16” 32” Panel Properties Gage 26 24 22 20 Weight w psf 1.1 1.4 1.7 2.0 Compression Gage 26 24 22 20 Area Ae in2/ft 0.285 0.390 0.482 0.574 Base Metal Thickness Yield Strength t Fy in ksi 0.0195 80 0.0254 80 0.0314 80 0.0374 80 Tensile Strength Fu ksi 82 82 82 82 Area Ag in2/ft 0.299 0.390 0.482 0.574 Effective Section Modulus at Fy Bending Section Modulus Se+ in3/ft 0.061 0.080 0.098 0.116 Distance to N.A. from Bottom yb in 0.45 0.45 0.46 0.45 Section Modulus Sein3/ft 0.060 0.080 0.098 0.116 26 End Interior 1" 377 473 Allowable (Rn/Ω) 1.5" 2" 431 460 532 562 24 End Interior 699 950 795 1060 22 End Interior 1117 1585 20 End Interior 1627 2370 Condition Web Crippling Constraints 140 Radius of Gyration r in 0.306 0.306 0.305 0.305 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 0.46 0.45 0.46 0.45 Reactions at Supports (plf) Based on Web Crippling Gage Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Ig yb Sg in4/ft in in3/ft 0.028 0.44 0.062 0.036 0.44 0.080 0.045 0.46 0.098 0.053 0.46 0.116 Moment of Inertia Ie+ in4/ft 0.028 0.036 0.045 0.053 Bearing Length of Webs Moment of Inertia I ein4/ft 0.028 0.036 0.045 0.053 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 0.028 0.036 0.045 0.053 Iin4/ft 0.028 0.036 0.045 0.053 3" 460 562 1" 577 724 Factored (ΦRn) 1.5" 2" 660 703 814 860 3" 703 860 844 1117 844 1117 1069 1453 1216 1622 1292 1710 1292 1710 1264 1760 1341 1850 1341 1850 1710 2425 1935 2692 2052 2831 2052 2831 1833 2619 1940 2749 1940 2749 2489 3626 2804 4007 2968 4206 2968 4206 h=0.6" r=0.63" Composite and Non-Composite Deck Catalog • February 2016 θ=48.8º www.ascsd.com TABLE OF CONTENTS C0.9-32 6.2 Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) Gage Span Limit Condition SS Φ fb L/360 L/240 fb / Ω 26 DS Φ fb L/360 fb / Ω TS Φ fb L/360 L/240 fb / Ω SS L/360 L/240 fb / Ω 24 DS Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω 20 DS Φ fb L/360 L/240 TS Φ fb L/360 L/240 www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 141 ACUSTADEK® fb / Ω 6' - 0" 41 65 6 9 40 63 14 21 50 79 13 19 53 84 7 11 53 84 18 27 67 106 16 24 65 104 9 14 65 104 22 33 82 129 20 30 77 122 11 16 77 122 26 38 96 153 23 35 D PANEL SS 5' - 6" 49 77 7 11 47 75 18 27 59 94 16 24 63 101 10 14 63 101 23 35 79 126 21 32 78 123 12 18 78 123 28 43 97 154 26 39 92 146 14 21 92 146 33 50 115 182 30 46 C PANELS 22 5' - 0" 59 93 10 15 57 91 24 36 71 113 22 33 77 122 13 19 77 122 31 46 96 152 28 42 94 149 16 24 94 149 38 57 118 186 35 52 111 176 18 28 111 176 44 66 139 220 41 61 N PANELS TS Panel Span (Support Spacing) 3' - 6" 4' - 0" 4' - 6" 120 92 73 190 146 115 29 19 13 43 29 20 116 89 70 185 141 112 69 46 32 104 69 49 146 111 88 231 177 140 63 42 30 95 64 45 156 120 95 248 190 150 37 25 17 56 37 26 156 120 95 248 190 150 89 60 42 134 90 63 196 150 118 310 238 188 82 55 39 123 82 58 192 147 116 304 233 184 46 31 22 69 46 32 192 147 116 304 233 184 110 74 52 166 111 78 240 184 145 381 291 230 101 68 48 152 102 71 227 174 137 360 275 218 54 36 25 80 54 38 227 174 137 360 275 218 129 86 61 193 130 91 283 217 171 450 344 272 118 79 56 177 119 83 B PANELS Φ fb 3' - 0" 163 259 46 68 158 251 110 198 314 100 151 213 338 59 88 213 338 142 213 266 422 130 195 261 414 73 109 261 414 175 326 518 161 241 309 490 85 127 309 490 205 307 386 612 188 281 2W PANELS L/240 2' - 6" 235 373 79 118 228 362 189 285 453 174 260 307 487 102 153 307 487 245 383 608 225 337 376 597 126 189 376 597 303 470 746 278 417 445 705 147 220 445 705 354 556 882 324 486 3W PANELS fb / Ω 2' - 0" 367 582 154 230 357 566 446 707 339 479 760 199 298 479 760 479 599 950 439 588 932 246 369 588 932 735 1165 543 695 1102 287 430 695 1102 691 868 1377 633 - GENERAL INFORMATION TABLE OF CONTENTS 6.3 C0.9-32 Normal Weight Concrete (145 pcf) Maximum Unshored Spans C0.9-32 Shoring Table Total Slab Depth (in) Volume cy/100sf 2.5 0.637 3 3.5 4 4.5 5 5.5 6 6.5 142 Gage 26 24 22 20 145 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 26.0 3' - 9" 4' - 4" 26.3 4' - 7" 5' - 5" 26.6 5' - 1" 6' - 3" 26.9 5' - 4" 7' - 0" Triple 4' - 6" 5' - 6" 6' - 4" 6' - 7" 0.791 26 24 22 20 32.0 32.3 32.7 33.0 3' - 7" 4' - 4" 4' - 10" 5' - 0" 4' - 2" 5' - 2" 5' - 11" 6' - 8" 4' - 3" 5' - 2" 5' - 11" 6' - 3" 0.945 26 24 22 20 38.1 38.4 38.7 39.0 3' - 5" 4' - 2" 4' - 7" 4' - 9" 4' - 0" 4' - 11" 5' - 8" 6' - 4" 4' - 1" 5' - 0" 5' - 8" 5' - 11" 1.100 26 24 22 20 44.1 44.4 44.7 45.1 3' - 4" 4' - 0" 4' - 4" 4' - 7" 3' - 10" 4' - 8" 5' - 5" 6' - 0" 3' - 11" 4' - 9" 5' - 5" 5' - 8" 1.254 26 24 22 20 50.2 50.5 50.8 51.1 3' - 2" 3' - 10" 4' - 2" 4' - 5" 3' - 8" 4' - 6" 5' - 2" 5' - 9" 3' - 10" 4' - 7" 5' - 2" 5' - 5" 1.408 26 24 22 20 56.2 56.5 56.8 57.1 3' - 1" 3' - 9" 4' - 0" 4' - 3" 3' - 7" 4' - 4" 5' - 0" 5' - 7" 3' - 8" 4' - 5" 5' - 0" 5' - 3" 1.563 26 24 22 20 62.2 62.6 62.9 63.2 3' - 0" 3' - 7" 3' - 11" 4' - 1" 3' - 6" 4' - 3" 4' - 10" 5' - 5" 3' - 7" 4' - 3" 4' - 10" 5' - 1" 1.717 26 24 22 20 68.3 68.6 68.9 69.2 2' - 11" 3' - 6" 3' - 10" 4' - 0" 3' - 4" 4' - 1" 4' - 8" 5' - 3" 3' - 6" 4' - 2" 4' - 8" 4' - 11" 1.871 26 24 22 20 74.3 74.6 74.9 75.3 2' - 10" 3' - 5" 3' - 8" 3' - 11" 3' - 3" 4' - 0" 4' - 7" 5' - 1" 3' - 5" 4' - 1" 4' - 7" 4' - 10" Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS C0.9-32 6.3 Light Weight Concrete (110 pcf) Maximum Unshored Spans 3W PANELS C0.9-32 Shoring Table Volume cy/100sf 2.5 0.637 3 4 5.5 6.5 4' - 5" 5' - 6" 6' - 5" 7' - 2" 4' - 7" 5' - 7" 6' - 6" 6' - 10" 0.945 26 24 22 20 29.1 29.5 29.8 30.1 3' - 8" 4' - 6" 5' - 0" 5' - 3" 4' - 3" 5' - 4" 6' - 1" 6' - 10" 4' - 5" 5' - 4" 6' - 2" 6' - 6" 1.100 26 24 22 20 33.7 34.0 34.3 34.7 3' - 7" 4' - 4" 4' - 9" 5' - 0" 4' - 1" 5' - 1" 5' - 11" 6' - 7" 4' - 3" 5' - 2" 5' - 11" 6' - 2" 1.254 26 24 22 20 38.3 38.6 38.9 39.2 3' - 5" 4' - 2" 4' - 7" 4' - 10" 4' - 0" 4' - 11" 5' - 8" 6' - 4" 4' - 2" 5' - 0" 5' - 8" 5' - 11" 1.408 26 24 22 20 42.9 43.2 43.5 43.8 3' - 4" 4' - 1" 4' - 5" 4' - 8" 3' - 10" 4' - 9" 5' - 6" 6' - 1" 4' - 0" 4' - 10" 5' - 6" 5' - 9" 1.563 26 24 22 20 47.5 47.8 48.1 48.4 3' - 3" 3' - 11" 4' - 3" 4' - 6" 3' - 9" 4' - 8" 5' - 4" 5' - 11" 3' - 11" 4' - 8" 5' - 3" 5' - 7" 1.717 26 24 22 20 52.1 52.4 52.7 53.0 3' - 2" 3' - 10" 4' - 2" 4' - 4" 3' - 8" 4' - 6" 5' - 2" 5' - 9" 3' - 10" 4' - 7" 5' - 2" 5' - 5" 1.871 26 24 22 20 56.6 57.0 57.3 57.6 3' - 1" 3' - 8" 4' - 1" 4' - 3" 3' - 6" 4' - 4" 5' - 0" 5' - 7" 3' - 8" 4' - 5" 5' - 1" 5' - 8" Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® www.ascsd.com 3' - 10" 4' - 8" 5' - 3" 5' - 6" D PANEL 6 24.6 24.9 25.2 25.5 C PANELS 5 0.791 26 24 22 20 N PANELS 4.5 Triple 4' - 9" 5' - 10" 6' - 10" 7' - 3" B PANELS 3.5 Gage 26 24 22 20 110 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 20.0 4' - 0" 4' - 7" 20.3 4' - 10" 5' - 10" 20.6 5' - 7" 6' - 9" 20.9 5' - 10" 7' - 7" 2W PANELS Total Slab Depth (in) GENERAL INFORMATION 143 TABLE OF CONTENTS 6.4 C1.4-32 4-9/16” 1-3/8” 15/16” 32” RD16 CP-32 Panel Properties Gage 26 24 22 20 18 Weight w psf 1.1 1.4 1.7 2.0 2.6 Compression Gage 26 24 22 20 18 Area Ae in2/ft 0.172 0.265 0.367 0.473 0.722 Base Metal Thickness Yield Strength t Fy in ksi 0.0195 80 0.0254 80 0.0314 80 0.0374 80 0.0480 40 Tensile Strength Fu ksi 82 82 82 82 55 Area Ag in2/ft 0.302 0.393 0.485 0.576 0.737 Effective Section Modulus at Fy Bending Section Modulus Se+ in3/ft 0.101 0.139 0.175 0.206 0.261 Distance to N.A. from Bottom yb in 0.65 0.67 0.68 0.68 0.68 Section Modulus Sein3/ft 0.106 0.141 0.174 0.206 0.261 26 End Interior 1" 315 559 Allowable (Rn/Ω) 2" 4" 399 517 686 865 24 End Interior 533 936 668 1136 22 End Interior 807 1410 20 End Interior 18 End Interior Condition Distance to N.A. from Bottom yb in 0.69 0.68 0.67 0.68 0.68 Moment of Inertia Ie+ in4/ft 0.078 0.103 0.128 0.150 0.191 Bearing Length of Webs Moment of Inertia I ein4/ft 0.078 0.103 0.128 0.150 0.191 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 0.079 0.103 0.128 0.150 0.191 Iin4/ft 0.078 0.103 0.128 0.150 0.191 6" 522 873 1" 482 855 Factored (ΦRn) 2" 4" 610 791 1049 1324 6" 798 1335 858 1419 959 1568 815 1432 1021 1738 1313 2171 1467 2399 1003 1696 1280 2101 1439 2333 1235 2158 1535 2595 1958 3214 2201 3569 1134 1974 1399 2357 1773 2898 1988 3209 1735 3021 2140 3606 2713 4434 3042 4909 1223 2124 1493 2508 1875 3052 2094 3364 1871 3250 2284 3838 2868 4669 3204 5147 Web Crippling Constraints 144 Radius of Gyration r in 0.512 0.511 0.511 0.510 0.509 Effective Moment of Inertia for Deflection Reactions at Supports (plf) Based on Web Crippling Gage Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Ig yb Sg in4/ft in in3/ft 0.079 0.67 0.118 0.103 0.67 0.153 0.128 0.67 0.188 0.150 0.68 0.222 0.191 0.68 0.280 h=1.82" r=0.125" Composite and Non-Composite Deck Catalog • February 2016 θ=45º www.ascsd.com TABLE OF CONTENTS C1.4-32 6.5 Gage Span SS DS TS SS DS TS SS DS TS 20 DS TS 18 DS TS 5' - 6" 80 126 21 31 84 134 50 75 105 167 46 68 110 175 27 40 111 177 65 98 139 221 60 89 138 219 33 50 138 219 81 121 172 274 74 111 163 259 39 59 163 259 95 142 204 324 87 130 138 219 50 75 138 219 121 172 274 111 166 Composite and Non-Composite Deck Catalog • February 2016 6' - 0" 67 106 16 24 71 112 38 57 88 140 35 53 92 147 21 31 94 149 50 75 117 186 46 69 116 184 26 39 116 184 62 93 145 230 57 85 137 218 30 46 137 218 73 110 172 272 67 100 116 184 39 58 116 184 93 145 230 85 128 145 ACUSTADEK® www.ascsd.com 5' - 0" 96 153 27 41 102 162 66 99 127 202 61 91 133 211 36 54 135 214 87 130 169 268 79 119 167 265 45 67 167 265 107 161 209 331 98 148 198 314 52 79 198 314 126 189 247 392 116 174 167 265 67 100 167 265 161 209 331 148 - D PANEL SS Panel Span (Support Spacing) 3' - 6" 4' - 0" 4' - 6" 197 151 119 312 239 189 80 54 38 120 81 57 208 159 126 330 253 200 193 129 91 260 199 157 412 316 249 177 118 83 178 125 272 208 164 431 330 261 105 70 49 157 105 74 275 211 167 437 334 264 252 169 119 344 263 208 546 418 330 231 155 109 232 163 341 261 206 542 415 328 130 87 61 195 131 92 341 261 206 540 414 327 313 210 147 426 326 258 676 517 409 287 192 135 288 202 403 309 244 640 490 387 153 102 72 229 154 108 403 309 244 640 490 387 368 247 173 504 386 305 800 612 484 337 226 159 339 238 341 261 206 541 414 327 195 131 92 292 196 138 341 261 206 541 414 327 426 326 258 676 517 409 288 202 - C PANELS SS 3' - 0" 268 425 127 191 283 449 354 561 281 370 587 166 249 375 595 468 743 367 465 737 206 310 464 736 580 920 455 549 871 243 364 549 871 686 1089 536 464 736 310 464 736 580 920 - N PANELS 22 2' - 6" 386 612 220 330 408 647 509 808 485 533 845 287 431 540 856 675 1070 634 669 1061 357 535 668 1059 835 1324 787 791 1254 420 629 791 1254 988 1568 926 668 1059 535 668 1059 835 1324 - B PANELS 24 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 2' - 0" 603 957 430 637 1010 796 1263 832 1320 561 843 1338 1054 1672 1045 1658 697 1045 1043 1655 1304 2069 1235 1960 819 1229 1235 1960 1544 2450 1043 1655 1043 1655 1304 2069 - 2W PANELS 26 Limit Condition 3W PANELS Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) GENERAL INFORMATION TABLE OF CONTENTS 6.6 C1.4-32 Normal Weight Concrete (145 pcf) Maximum Unshored Spans C1.4-32 Shoring Table Total Slab Depth (in) Volume cy/100sf 3 0.714 3.5 4 4.5 5 5.5 6 6.5 146 Gage 26 24 22 20 18 145 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 29.0 5' - 3" 6' - 5" 29.3 6' - 6" 7' - 10" 29.6 7' - 0" 8' - 11" 29.9 7' - 4" 9' - 8" 30.5 7' - 8" 8' - 10" Triple 6' - 3" 7' - 10" 8' - 8" 9' - 1" 9' - 1" 0.868 26 24 22 20 18 35.1 35.4 35.7 36.0 36.5 5' - 0" 6' - 2" 6' - 7" 6' - 11" 7' - 3" 6' - 1" 7' - 5" 8' - 5" 9' - 2" 8' - 4" 6' - 0" 7' - 5" 8' - 2" 8' - 7" 8' - 6" 1.022 26 24 22 20 18 41.1 41.4 41.7 42.0 42.6 4' - 10" 5' - 10" 6' - 4" 6' - 8" 6' - 10" 5' - 10" 7' - 0" 8' - 0" 8' - 9" 8' - 0" 5' - 8" 7' - 1" 7' - 9" 8' - 2" 8' - 1" 1.177 26 24 22 20 18 47.1 47.4 47.8 48.1 48.6 4' - 7" 5' - 8" 6' - 0" 6' - 4" 6' - 7" 5' - 7" 6' - 9" 7' - 8" 8' - 4" 7' - 8" 5' - 6" 6' - 9" 7' - 5" 7' - 10" 7' - 9" 1.331 26 24 22 20 18 53.2 53.5 53.8 54.1 54.7 4' - 5" 5' - 5" 5' - 10" 6' - 2" 6' - 4" 5' - 5" 6' - 5" 7' - 4" 8' - 0" 7' - 4" 5' - 3" 6' - 6" 7' - 2" 7' - 7" 7' - 5" 1.485 26 24 22 20 18 59.2 59.5 59.8 60.2 60.7 4' - 3" 5' - 3" 5' - 7" 5' - 11" 6' - 1" 5' - 2" 6' - 3" 7' - 1" 7' - 8" 7' - 1" 5' - 1" 6' - 3" 6' - 11" 7' - 4" 7' - 2" 1.640 26 24 22 20 18 65.3 65.6 65.9 66.2 66.8 4' - 2" 5' - 1" 5' - 5" 5' - 9" 5' - 11" 5' - 0" 6' - 0" 6' - 10" 7' - 5" 6' - 10" 4' - 11" 6' - 0" 6' - 9" 7' - 1" 6' - 11" 1.794 26 24 22 20 18 71.3 71.6 71.9 72.2 72.8 4' - 0" 4' - 11" 5' - 4" 5' - 7" 5' - 8" 4' - 11" 5' - 10" 6' - 8" 7' - 2" 6' - 7" 4' - 9" 5' - 10" 6' - 7" 6' - 11" 6' - 8" Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS C1.4-32 6.6 Light Weight Concrete (110 pcf) Maximum Unshored Spans Volume cy/100sf 3 0.714 3.5 5 www.ascsd.com 6' - 8" 8' - 1" 9' - 2" 10' - 0" 9' - 1" 6' - 6" 8' - 1" 8' - 11" 9' - 5" 9' - 4" 1.022 26 24 22 20 18 31.4 31.7 32.1 32.4 32.9 5' - 2" 6' - 5" 6' - 11" 7' - 3" 7' - 6" 6' - 4" 7' - 9" 8' - 9" 9' - 6" 8' - 9" 6' - 3" 7' - 9" 8' - 6" 9' - 0" 8' - 11" 1.177 26 24 22 20 18 36.0 36.3 36.6 37.0 37.5 5' - 0" 6' - 2" 6' - 7" 7' - 0" 7' - 3" 6' - 1" 7' - 5" 8' - 5" 9' - 2" 8' - 4" 6' - 0" 7' - 5" 8' - 2" 8' - 7" 8' - 6" 1.331 26 24 22 20 18 40.6 40.9 41.2 41.5 42.1 4' - 10" 5' - 11" 6' - 4" 6' - 8" 6' - 11" 5' - 11" 7' - 1" 8' - 1" 8' - 10" 8' - 1" 5' - 9" 7' - 2" 7' - 10" 8' - 3" 8' - 2" 1.485 26 24 22 20 18 45.2 45.5 45.8 46.1 46.7 4' - 8" 5' - 9" 6' - 2" 6' - 6" 6' - 8" 5' - 9" 6' - 10" 7' - 10" 8' - 6" 7' - 10" 5' - 7" 6' - 11" 7' - 7" 8' - 0" 7' - 11" 1.640 26 24 22 20 18 49.8 50.1 50.4 50.7 51.3 4' - 7" 5' - 7" 6' - 0" 6' - 4" 6' - 6" 5' - 6" 6' - 8" 7' - 7" 8' - 3" 7' - 7" 5' - 5" 6' - 8" 7' - 5" 7' - 9" 7' - 8" 1.794 26 24 22 20 18 54.4 54.7 55.0 55.3 55.8 4' - 5" 5' - 5" 5' - 10" 6' - 1" 6' - 4" 5' - 5" 6' - 5" 7' - 4" 8' - 0" 7' - 4" 5' - 3" 6' - 6" 7' - 2" 7' - 7" 7' - 5" Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® 6.5 5' - 5" 6' - 9" 7' - 3" 7' - 7" 7' - 11" D PANEL 6 26.9 27.2 27.5 27.8 28.3 C PANELS 5.5 0.868 26 24 22 20 18 N PANELS 4.5 Triple 6' - 10" 8' - 7" 9' - 5" 9' - 11" 9' - 11" B PANELS 4 Gage 26 24 22 20 18 110 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 22.3 5' - 8" 7' - 0" 22.6 7' - 2" 8' - 6" 22.9 7' - 8" 9' - 8" 23.2 8' - 1" 10' - 6" 23.8 8' - 4" 9' - 7" 2W PANELS Total Slab Depth (in) 3W PANELS C1.4-32 Shoring Table GENERAL INFORMATION 147 TABLE OF CONTENTS 7.1 4.5D-12 9” 4-1/2” 12” 2 Welds Panel Properties Gage 20 18 16 14 Weight w psf 2.88 3.84 4.80 6.09 Compression Gage 20 18 16 14 Area Ae in2/ft 0.513 0.801 1.147 1.599 Base Metal Thickness Yield Strength t Fy in ksi 0.0359 33 0.0478 33 0.0598 33 0.075 33 Tensile Strength Fu ksi 45 45 45 45 Area Ag in2/ft 0.848 1.132 1.432 1.785 Effective Section Modulus at Fy Bending Section Modulus Se+ in3/ft 0.927 1.335 1.723 2.166 Distance to N.A. from Bottom yb in 2.20 2.37 2.51 2.63 Section Modulus Sein3/ft 1.045 1.398 1.755 2.166 20 End Interior 1" 222 226 Allowable (Rn/Ω) 2" 4" 294 396 264 318 18 End Interior 444 444 584 513 16 End Interior 736 737 14 End Interior 1227 1241 Condition Web Crippling Constraints 148 Radius of Gyration r in 1.805 1.799 1.793 1.786 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 2.63 2.62 2.62 2.63 Reactions at Supports (plf) Based on Web Crippling Gage Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Ig yb Sg in4/ft in in3/ft 2.763 2.62 1.056 3.665 2.62 1.398 4.605 2.62 1.755 5.691 2.63 2.166 Moment of Inertia Ie+ in4/ft 2.134 3.159 4.330 5.691 Bearing Length of Webs Moment of Inertia I ein4/ft 2.743 3.665 4.605 5.691 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 2.344 3.328 4.422 5.691 Iin4/ft 2.750 3.665 4.605 5.691 8" 520 384 1" 333 346 Factored (ΦRn) 2" 4" 441 594 404 487 8" 780 588 781 611 1060 749 666 680 876 786 1172 935 1590 1146 960 843 1278 994 1727 1206 1104 1127 1440 1290 1917 1520 2590 1846 1590 1407 2102 1641 2827 1972 1841 1899 2384 2153 3153 2511 4240 3017 h=4.2" r=0.125" Composite and Non-Composite Deck Catalog • February 2016 θ=90º www.ascsd.com TABLE OF CONTENTS 4.5D-12 7.2 Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) Gage Span Limit Condition SS Φ fb L/360 L/240 fb / Ω 20 DS Φ fb L/360 fb / Ω TS Φ fb L/360 L/240 fb / Ω SS L/360 L/240 fb / Ω 18 DS Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 L/240 fb / Ω L/360 L/240 fb / Ω 14 DS Φ fb L/360 L/240 TS Φ fb L/360 L/240 www.ascsd.com 54 86 25 37 158 250 112 161 255 - 116 184 70 106 118 187 - 89 141 47 71 90 143 - 70 111 33 50 198 314 144 198 314 - 146 231 91 136 146 231 - 111 177 61 91 111 177 - 88 140 43 64 22 36 7 10 20 31 5 8 29 46 9 13 25 40 7 11 36 58 11 17 32 50 9 14 Exceeds Maximum Product Length 44 70 18 27 36 58 14 20 31 48 11 16 26 41 8 12 Exceeds Maximum Product Length 57 90 24 36 47 74 18 27 39 63 14 21 34 53 11 16 Exceeds Maximum Product Length 71 113 31 47 59 94 23 35 50 79 18 27 42 67 14 21 Exceeds Maximum Product Length Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® fb / Ω 69 109 36 53 72 114 - 30' - 0" 14 22 4 6 D PANEL SS Φ fb 90 142 53 79 94 149 - 28' - 0" 16 25 5 7 C PANELS 16 122 194 84 128 203 - 26' - 0" 18 29 6 9 N PANELS TS 16' - 0" 48 76 25 38 54 85 - B PANELS Φ fb 14' - 0" 62 99 37 56 70 111 - 2W PANELS L/240 Panel Span (Support Spacing) 18' - 0" 20' - 0" 22' - 0" 24' - 0" 38 31 25 21 60 48 40 34 18 13 10 7 26 19 14 11 12' - 0" 85 134 59 96 152 - 3W PANELS fb / Ω 10' - 0" 122 194 102 138 218 172 273 176 279 145 184 292 230 365 227 360 193 231 367 289 459 285 453 249 285 453 357 566 - GENERAL INFORMATION 149 TABLE OF CONTENTS 7.3 4.5D-12 Normal Weight Concrete (145 pcf) Maximum Unshored Spans 4.5D-12 Shoring Table Total Slab Depth (in) Volume cy/100sf 6 0.810 6 1/2 0.965 7 1.119 7 1/2 1.273 8 1.427 8 1/2 1.582 9 1.736 9 1/2 1.890 10 2.045 Gage 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 145 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 34.6 14' - 6" 15' - 6" 35.6 17' - 1" 16' - 0" 36.5 18' - 3" 16' - 0" 37.8 19' - 3" 16' - 0" 40.6 13' - 8" 14' - 8" 41.6 16' - 6" 16' - 0" 42.6 17' - 7" 16' - 0" 43.8 18' - 7" 16' - 0" 46.7 12' - 11" 14' - 1" 47.6 15' - 9" 16' - 0" 48.6 17' - 1" 16' - 0" 49.9 18' - 1" 16' - 0" 52.7 12' - 4" 13' - 6" 53.7 15' - 2" 15' - 6" 54.6 16' - 7" 16' - 0" 55.9 17' - 7" 16' - 0" 58.8 11' - 10" 13' - 0" 59.7 14' - 6" 14' - 11" 60.7 16' - 2" 16' - 0" 62.0 17' - 2" 16' - 0" 64.8 11' - 5" 12' - 6" 65.8 13' - 11" 14' - 5" 66.7 15' - 10" 16' - 0" 68.0 16' - 9" 16' - 0" 70.8 11' - 0" 12' - 1" 71.8 13' - 5" 13' - 11" 72.8 15' - 5" 15' - 6" 74.1 16' - 5" 16' - 0" 76.9 10' - 8" 11' - 9" 77.9 13' - 0" 13' - 6" 78.8 14' - 11" 15' - 1" 80.1 16' - 1" 16' - 0" 82.9 10' - 4" 11' - 5" 83.9 12' - 7" 13' - 2" 84.9 14' - 5" 14' - 8" 86.1 15' - 10" 16' - 0" Triple 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span. 150 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 4.5D-12 7.3 Light Weight Concrete (110 pcf) Maximum Unshored Spans 6 1/2 0.965 7 1.119 7 1/2 1.273 8 1.427 8 1/2 1.582 9 1.736 9 1/2 1.890 10 2.045 C PANELS 0.810 Triple 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" N PANELS 6 Gage 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 110 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 26.9 15' - 7" 16' - 0" 27.9 18' - 2" 16' - 0" 28.9 19' - 5" 16' - 0" 30.1 20' - 5" 16' - 0" 31.5 15' - 1" 16' - 0" 32.5 17' - 7" 16' - 0" 33.4 18' - 9" 16' - 0" 34.7 19' - 9" 16' - 0" 36.1 14' - 5" 15' - 5" 37.1 17' - 0" 16' - 0" 38.0 18' - 2" 16' - 0" 39.3 19' - 2" 16' - 0" 40.7 13' - 9" 14' - 10" 41.7 16' - 7" 16' - 0" 42.6 17' - 8" 16' - 0" 43.9 18' - 8" 16' - 0" 45.3 13' - 2" 14' - 4" 46.2 16' - 1" 16' - 0" 47.2 17' - 3" 16' - 0" 48.5 18' - 3" 16' - 0" 49.9 12' - 9" 13' - 10" 50.8 15' - 6" 15' - 11" 51.8 16' - 10" 16' - 0" 53.1 17' - 10" 16' - 0" 54.4 12' - 3" 13' - 5" 55.4 15' - 1" 15' - 5" 56.4 16' - 6" 16' - 0" 57.6 17' - 6" 16' - 0" 59.0 11' - 11" 13' - 0" 60.0 14' - 7" 15' - 0" 60.9 16' - 3" 16' - 0" 62.2 17' - 2" 16' - 0" 63.6 11' - 7" 12' - 8" 64.6 14' - 2" 14' - 7" 65.5 15' - 11" 16' - 0" 66.8 16' - 11" 16' - 0" B PANELS Volume cy/100sf 2W PANELS Total Slab Depth (in) 3W PANELS 4.5D-12 Shoring Table GENERAL INFORMATION D PANEL Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span. ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 151 TABLE OF CONTENTS 7.4 4.5DF-24 4-1/2” 24” RD31 4-1/2” Deep Deck Cellular Panel Properties Gage Weight w psf 4.53 5.02 5.55 5.49 5.98 6.51 6.45 6.94 7.47 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Compression Gage Area Ae in2/ft 0.957 1.101 1.249 1.244 1.401 1.548 1.499 1.659 1.820 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Base Metal Thickness Yield Strength t Fy in ksi .0359/.036 33 .0359/.047 33 .0359/.059 33 .0478/.036 33 .0478/.047 33 .0478/.059 33 .0598/.036 33 .0598/.047 33 .0598/.059 33 Tensile Strength Fu ksi 45 45 45 45 45 45 45 45 45 Area Ag in2/ft 1.193 1.353 1.514 1.439 1.599 1.760 1.685 1.845 2.005 Effective Section Modulus at Fy Bending Section Modulus Se+ in3/ft 1.008 1.026 1.038 1.526 1.555 1.576 2.110 2.152 2.184 Distance to N.A. from Bottom yb in 1.53 1.31 1.15 1.86 1.67 1.52 2.11 1.93 1.78 Section Modulus Sein3/ft 1.559 1.581 1.742 1.445 1.835 2.269 1.720 2.110 2.563 Condition Distance to N.A. from Bottom yb in 3.05 2.72 2.42 3.12 2.87 2.62 3.14 2.94 2.74 Moment of Inertia Ie+ in4/ft 3.649 3.839 3.978 4.987 5.435 5.800 6.264 6.858 7.357 Bearing Length of Webs Moment of Inertia I ein4/ft 3.629 4.299 4.920 4.509 5.266 6.001 5.400 6.213 7.030 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 4.008 4.290 4.506 5.252 5.747 6.152 6.427 7.052 7.579 Iin4/ft 3.995 4.597 5.135 4.933 5.634 6.286 5.851 6.622 7.361 8" 520 384 1" 333 346 Factored (ΦRn) 2" 4" 441 594 404 487 8" 780 588 20 End Interior 1" 222 226 18 End Interior 444 444 584 513 781 611 1060 749 666 680 876 786 1172 935 1590 1146 16 End Interior 736 737 960 843 1278 994 1727 1206 1104 1127 1440 1290 1917 1520 2590 1846 14 End Interior 1227 1241 1590 1407 2102 1641 2827 1972 1841 1899 2384 2153 3153 2511 4240 3017 Web Crippling Constraints 152 Allowable (Rn/Ω) 2" 4" 294 396 264 318 Radius of Gyration r in 1.991 1.959 1.917 2.004 1.996 1.974 2.002 2.008 2.000 Effective Moment of Inertia for Deflection Reactions at Supports (plf) Based on Web Crippling Beam Gage Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Ig yb Sg in4/ft in in3/ft 4.727 1.85 2.559 5.193 1.64 3.161 5.564 1.48 3.753 5.781 2.05 2.817 6.369 1.86 3.424 6.856 1.70 4.022 6.753 2.20 3.070 7.440 2.02 3.680 8.024 1.87 4.282 h=4.2" r=0.125" Composite and Non-Composite Deck Catalog • February 2016 θ=90º www.ascsd.com TABLE OF CONTENTS 4.5DF-24 7.5 Gage Span Limit Condition fb / Ω SS Φ fb L/360 fb / Ω 20/20 DS Φ fb L/360 L/240 fb / Ω L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω DS L/360 L/240 fb / Ω TS Φ fb L/360 L/240 SS Φ fb L/360 L/240 fb / Ω 20/16 DS Φ fb L/360 fb / Ω TS Φ fb L/360 L/240 28' - 0" 30' - 0" 133 211 92 146 68 108 52 82 41 65 33 53 27 44 23 37 20 31 17 27 15 23 - - 64 - 43 - 30 - 22 33 16 25 13 19 10 15 8 12 6 10 205 326 143 226 105 166 80 127 63 101 51 81 - - - - - - 135 214 94 149 69 109 53 84 42 66 34 54 28 44 23 37 20 32 17 27 15 24 - - 68 - 46 - 32 - 23 - 18 26 14 20 11 16 9 13 7 10 208 330 145 229 106 169 81 129 64 102 52 83 - - - - - - 137 217 95 151 70 111 53 85 42 67 34 54 28 45 24 38 20 32 17 28 15 24 - - - 48 - 34 - 25 - 18 28 14 21 11 17 9 13 7 11 229 364 159 253 117 186 90 142 71 112 57 91 - - - - - - Exceeds Maximum Product Length 208 329 - Exceeds Maximum Product Length 211 335 - 214 339 Exceeds Maximum Product Length D PANEL L/240 26' - 0" C PANELS fb / Ω 16' - 0" N PANELS 20/18 Φ fb 14' - 0" B PANELS TS Φ fb 12' - 0" 2W PANELS L/240 Panel Span (Support Spacing) 18' - 0" 20' - 0" 22' - 0" 24' - 0" 10' - 0" 3W PANELS Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) GENERAL INFORMATION - ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 153 TABLE OF CONTENTS 7.5 4.5DF-24 Normal Weight Concrete (145 pcf) Maximum Unshored Spans Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) Gage Span Limit Condition fb / Ω SS Φ fb L/360 L/240 fb / Ω 18/20 DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω 18/18 DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω 18/16 DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 L/240 154 Panel Span (Support Spacing) 18' - 0" 20' - 0" 22' - 0" 24' - 0" 10' - 0" 12' - 0" 14' - 0" 16' - 0" 26' - 0" 28' - 0" 30' - 0" 201 319 140 221 103 163 79 125 62 98 50 80 42 66 35 55 30 47 26 41 22 35 - 133 - 84 - 56 - 39 59 29 43 22 32 17 25 13 20 10 16 9 13 190 302 132 210 97 154 74 118 59 93 48 75 - - - - - - 205 325 142 226 104 166 80 127 63 100 51 81 42 67 36 56 30 48 26 41 23 36 - - 92 - 61 - 43 - 31 47 24 35 18 27 14 21 11 17 9 14 242 384 168 266 123 196 94 150 75 118 60 96 - - - - - - 208 329 144 229 106 168 81 129 64 102 52 82 43 68 36 57 31 49 26 42 23 37 - - 98 - 66 - 46 - 34 50 25 38 19 29 15 23 12 18 10 15 299 474 208 329 152 242 117 185 92 146 75 119 - - - - - - Exceeds Maximum Product Length 238 377 - Exceeds Maximum Product Length 302 479 - 324 515 Exceeds Maximum Product Length - Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 4.5DF-24 7.5 Light Weight Concrete (110 pcf) Maximum Unshored Spans Gage Span Limit Condition fb / Ω SS Φ fb L/360 16/20 DS Φ fb L/360 L/240 fb / Ω TS L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω DS L/360 L/240 fb / Ω TS Φ fb L/360 L/240 SS Φ fb L/360 L/240 fb / Ω 16/16 DS Φ fb L/360 fb / Ω TS Φ fb L/360 L/240 28' - 0" 30' - 0" 278 441 193 306 142 225 109 172 86 136 69 110 57 91 48 77 41 65 35 56 31 49 - 163 - 102 - 69 103 48 72 35 53 26 40 20 30 16 24 13 19 10 16 227 360 157 250 116 183 89 140 70 111 57 90 - - - - - - 284 450 197 312 145 230 111 176 88 139 71 112 59 93 49 78 42 67 36 57 32 50 - 178 - 112 - 75 - 53 79 39 58 29 43 22 33 18 26 14 21 11 17 278 441 193 306 142 225 109 172 86 136 70 110 - - - - - - 288 456 200 317 147 233 112 178 89 141 72 114 59 94 50 79 43 68 37 58 32 51 - 192 - 121 - 81 - 57 85 41 62 31 47 24 36 19 28 15 23 12 18 338 536 234 372 172 273 132 209 104 165 84 134 - - - - - - Exceeds Maximum Product Length 283 449 - Exceeds Maximum Product Length 348 551 - 422 669 Exceeds Maximum Product Length D PANEL L/240 26' - 0" C PANELS fb / Ω 16' - 0" N PANELS 16/18 Φ fb 14' - 0" B PANELS Φ fb 12' - 0" 2W PANELS L/240 fb / Ω Panel Span (Support Spacing) 18' - 0" 20' - 0" 22' - 0" 24' - 0" 10' - 0" 3W PANELS Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) GENERAL INFORMATION - ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 155 TABLE OF CONTENTS 7.6 4.5DF-24 Normal Weight Concrete (145 pcf) Maximum Unshored Spans 4.5DF-24 Shoring Table Total Slab Depth (in) Volume cy/100sf 6 0.821 7 1.130 8 1.438 9 1.747 10 2.056 Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 145 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 36.6 14' - 11" 17' - 1" 37.2 15' - 0" 17' - 1" 37.8 15' - 0" 17' - 1" 37.5 18' - 3" 17' - 9" 38.1 18' - 4" 19' - 11" 38.8 18' - 4" 20' - 0" 38.5 19' - 9" 19' - 2" 39.1 20' - 2" 20' - 0" 39.7 20' - 5" 20' - 0" 48.7 13' - 5" 15' - 6" 49.2 13' - 6" 15' - 7" 49.9 13' - 6" 15' - 8" 49.6 16' - 8" 16' - 2" 50.2 16' - 9" 18' - 2" 50.8 16' - 9" 19' - 2" 50.6 18' - 6" 17' - 7" 51.2 18' - 11" 19' - 4" 51.8 19' - 3" 20' - 0" 60.7 12' - 3" 14' - 4" 61.3 12' - 4" 14' - 5" 62.0 12' - 5" 14' - 6" 61.7 15' - 5" 15' - 0" 62.3 15' - 6" 16' - 10" 62.9 15' - 7" 17' - 9" 62.7 17' - 7" 16' - 3" 63.2 18' - 0" 17' - 11" 63.9 18' - 2" 19' - 9" 72.8 11' - 5" 13' - 5" 73.4 11' - 6" 13' - 6" 74.1 11' - 6" 13' - 7" 73.8 14' - 4" 14' - 0" 74.4 14' - 5" 15' - 9" 75.0 14' - 6" 16' - 7" 74.7 16' - 10" 15' - 3" 75.3 17' - 0" 16' - 10" 76.0 17' - 1" 18' - 6" 84.9 10' - 8" 12' - 8" 85.5 10' - 9" 12' - 9" 86.1 10' - 10" 12' - 9" 85.9 13' - 5" 13' - 3" 86.5 13' - 7" 14' - 10" 87.1 13' - 7" 15' - 8" 86.8 15' - 11" 14' - 4" 87.4 16' - 0" 15' - 10" 88.1 16' - 1" 17' - 5" Triple 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span. 156 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 4.5DF-24 7.6 Light Weight Concrete (110 pcf) Maximum Unshored Spans 1.130 8 1.438 9 1.747 10 2.056 D PANEL 7 C PANELS 0.821 Triple 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" N PANELS 6 ACUSTADEK® Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 110 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 28.8 16' - 2" 18' - 5" 29.4 16' - 3" 18' - 6" 30.0 16' - 3" 18' - 6" 29.8 19' - 8" 19' - 2" 30.4 19' - 9" 20' - 0" 31.0 19' - 10" 20' - 0" 30.8 21' - 0" 20' - 0" 31.3 21' - 4" 20' - 0" 31.9 21' - 8" 20' - 0" 38.0 14' - 10" 17' - 0" 38.6 14' - 11" 17' - 1" 39.2 14' - 11" 17' - 1" 39.0 18' - 2" 17' - 8" 39.5 18' - 3" 19' - 10" 40.1 18' - 3" 20' - 0" 39.9 19' - 9" 19' - 2" 40.5 20' - 1" 20' - 0" 41.1 20' - 5" 20' - 0" 47.2 13' - 8" 15' - 10" 47.7 13' - 9" 15' - 11" 48.4 13' - 9" 15' - 11" 48.1 16' - 11" 16' - 6" 48.7 17' - 0" 18' - 6" 49.3 17' - 1" 19' - 6" 49.1 18' - 9" 17' - 10" 49.7 19' - 2" 19' - 8" 50.3 19' - 5" 20' - 0" 56.3 12' - 9" 14' - 10" 56.9 12' - 10" 14' - 11" 57.5 12' - 10" 15' - 0" 57.3 15' - 11" 15' - 6" 57.9 16' - 0" 17' - 5" 58.5 16' - 1" 18' - 4" 58.3 18' - 0" 16' - 10" 58.8 18' - 5" 18' - 7" 59.4 18' - 8" 20' - 0" 65.5 12' - 0" 14' - 1" 66.1 12' - 1" 14' - 2" 66.7 12' - 1" 14' - 2" 66.5 15' - 1" 14' - 8" 67.0 15' - 2" 16' - 6" 67.6 15' - 3" 17' - 4" 67.4 17' - 5" 15' - 11" 68.0 17' - 9" 17' - 7" 68.6 17' - 10" 19' - 4" B PANELS Volume cy/100sf 2W PANELS Total Slab Depth (in) 3W PANELS 4.5DF-24 Shoring Table Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span. www.ascsd.com GENERAL INFORMATION Composite and Non-Composite Deck Catalog • February 2016 157 TABLE OF CONTENTS 7.7 6D-12 9” 6” 12” 2 Welds Panel Properties Gage 20 18 16 14 Weight w psf 3.25 4.33 5.41 6.86 Compression Gage 20 18 16 14 Area Ae in2/ft 0.516 0.810 1.143 1.638 Base Metal Thickness Yield Strength t Fy in ksi 0.0359 33 0.0478 33 0.0598 33 0.075 33 Tensile Strength Fu ksi 45 45 45 45 Area Ag in2/ft 0.953 1.273 1.591 2.010 Effective Section Modulus at Fy Bending Section Modulus Se+ in3/ft 1.369 1.981 2.529 3.242 Distance to N.A. from Bottom yb in 2.93 3.12 3.28 3.44 Section Modulus Sein3/ft 1.453 2.085 2.590 3.244 20 End Interior 1" 194 197 Allowable (Rn/Ω) 2" 4" 256 414 230 314 18 End Interior 400 400 525 462 16 End Interior 674 675 14 End Interior 1141 1154 Condition Web Crippling Constraints 158 Radius of Gyration r in 2.379 2.372 2.366 2.358 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 3.55 3.44 3.44 3.44 Reactions at Supports (plf) Based on Web Crippling Gage Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Ig yb Sg in4/ft in in3/ft 5.393 3.43 1.572 7.165 3.44 2.085 8.906 3.44 2.590 11.173 3.44 3.244 Moment of Inertia Ie+ in4/ft 4.211 6.180 8.304 11.144 Bearing Length of Webs Moment of Inertia I ein4/ft 5.154 7.165 8.906 11.173 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 4.605 6.508 8.505 11.154 Iin4/ft 5.234 7.165 8.906 11.173 8" 453 335 1" 290 301 Factored (ΦRn) 2" 4" 385 620 352 480 8" 680 512 839 617 954 674 600 612 788 707 1259 944 1431 1031 880 772 1394 1016 1582 1105 1011 1033 1319 1182 2091 1554 2373 1691 1478 1308 2319 1692 2628 1833 1711 1766 2216 2001 3479 2589 3941 2805 h=5.7" r=0.125" Composite and Non-Composite Deck Catalog • February 2016 θ=90º www.ascsd.com TABLE OF CONTENTS 6D-12 7.8 Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) Gage Span Limit Condition SS Φ fb L/360 L/240 fb / Ω 20 DS Φ fb L/360 fb / Ω TS Φ fb L/360 L/240 fb / Ω SS L/360 L/240 fb / Ω 18 DS Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 L/240 fb / Ω L/360 L/240 fb / Ω 14 DS Φ fb L/360 L/240 TS Φ fb L/360 L/240 www.ascsd.com 81 128 49 73 231 367 215 237 376 - 170 270 135 174 276 - 130 206 91 133 211 - 103 163 64 96 297 470 282 297 471 - 218 346 178 218 346 - 167 265 119 167 265 - 132 209 84 125 33 53 13 19 29 46 11 16 42 67 17 25 37 59 14 21 54 86 22 33 47 75 18 27 Exceeds Maximum Product Length 65 104 36 53 54 86 27 40 45 72 21 31 39 61 16 24 Exceeds Maximum Product Length 83 132 46 70 69 109 35 52 58 92 27 40 49 78 21 32 Exceeds Maximum Product Length 107 169 61 91 88 140 46 69 74 118 35 53 63 100 28 42 Exceeds Maximum Product Length Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® fb / Ω 102 162 69 107 170 - 30' - 0" 20 32 7 11 D PANEL SS Φ fb 133 211 104 140 222 - 28' - 0" 23 37 9 14 C PANELS 16 181 288 165 191 303 - 26' - 0" 27 42 11 17 N PANELS TS 16' - 0" 70 112 49 75 119 - B PANELS Φ fb 14' - 0" 92 146 73 98 155 - 2W PANELS L/240 Panel Span (Support Spacing) 18' - 0" 20' - 0" 22' - 0" 24' - 0" 56 45 37 31 88 72 59 50 35 25 19 15 52 38 28 22 12' - 0" 125 199 116 133 211 - 3W PANELS fb / Ω 10' - 0" 180 286 191 304 239 379 261 414 275 436 343 545 333 529 341 541 426 677 427 677 427 678 534 848 - GENERAL INFORMATION 159 TABLE OF CONTENTS 7.9 6D-12 Normal Weight Concrete (145 pcf) Maximum Unshored Spans 6D-12 Shoring Table Total Slab Depth (in) Volume cy/100sf 7 1/2 0.926 8 1.080 8 1/2 1.235 9 1.389 9 1/2 1.543 10 1.698 10 1/2 1.852 11 2.006 11 1/2 2.160 Gage 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 145 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 39.5 17' - 0" 16' - 0" 40.6 19' - 7" 16' - 0" 41.7 20' - 10" 16' - 0" 43.1 22' - 1" 16' - 0" 45.5 16' - 3" 16' - 0" 46.6 18' - 11" 16' - 0" 47.7 20' - 2" 16' - 0" 49.2 21' - 5" 16' - 0" 51.6 15' - 7" 16' - 0" 52.7 18' - 5" 16' - 0" 53.7 19' - 7" 16' - 0" 55.2 20' - 10" 16' - 0" 57.6 14' - 11" 15' - 5" 58.7 17' - 10" 16' - 0" 59.8 19' - 1" 16' - 0" 61.2 20' - 4" 16' - 0" 63.7 14' - 4" 14' - 10" 64.7 17' - 3" 16' - 0" 65.8 18' - 8" 16' - 0" 67.3 19' - 11" 16' - 0" 69.7 13' - 10" 14' - 4" 70.8 16' - 8" 16' - 0" 71.9 18' - 3" 16' - 0" 73.3 19' - 6" 16' - 0" 75.7 13' - 4" 13' - 11" 76.8 16' - 2" 16' - 0" 77.9 17' - 11" 16' - 0" 79.4 19' - 1" 16' - 0" 81.8 12' - 11" 13' - 6" 82.9 15' - 8" 16' - 0" 84.0 17' - 7" 16' - 0" 85.4 18' - 9" 16' - 0" 87.8 12' - 6" 13' - 2" 88.9 15' - 3" 15' - 8" 90.0 17' - 2" 16' - 0" 91.4 18' - 6" 16' - 0" Triple 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span. 160 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 6D-12 7.9 Light Weight Concrete (110 pcf) Maximum Unshored Spans 8 1.080 8 1/2 1.235 9 1.389 9 1/2 1.543 10 1.698 10 1/2 1.852 11 2.006 11 1/2 2.160 C PANELS 0.926 Triple 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" N PANELS 7 1/2 D PANEL 110 pcf Normal Weight Concrete Maximum Unshored Span Volume cy/100sf Single Double 30.7 18' - 6" 16' - 0" 31.8 20' - 10" 16' - 0" 32.9 22' - 2" 16' - 0" 34.4 23' - 5" 16' - 0" 35.3 17' - 9" 16' - 0" 36.4 20' - 3" 16' - 0" 37.5 21' - 6" 16' - 0" 38.9 22' - 9" 16' - 0" 39.9 17' - 1" 16' - 0" 41.0 19' - 8" 16' - 0" 42.1 20' - 11" 16' - 0" 43.5 22' - 2" 16' - 0" 44.5 16' - 6" 16' - 0" 45.6 19' - 2" 16' - 0" 46.7 20' - 4" 16' - 0" 48.1 21' - 8" 16' - 0" 49.1 15' - 11" 16' - 0" 50.2 18' - 9" 16' - 0" 51.2 19' - 11" 16' - 0" 52.7 21' - 2" 16' - 0" 53.7 15' - 5" 15' - 11" 54.7 18' - 4" 16' - 0" 55.8 19' - 6" 16' - 0" 57.3 20' - 9" 16' - 0" 58.2 15' - 0" 15' - 5" 59.3 17' - 11" 16' - 0" 60.4 19' - 2" 16' - 0" 61.9 20' - 4" 16' - 0" 62.8 14' - 6" 15' - 0" 63.9 17' - 5" 16' - 0" 65.0 18' - 10" 16' - 0" 66.4 20' - 0" 16' - 0" 67.4 14' - 1" 14' - 8" 68.5 17' - 0" 16' - 0" 69.6 18' - 6" 16' - 0" 71.0 19' - 8" 16' - 0" B PANELS Gage Slab and Deck psf 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 2W PANELS Total Slab Depth (in) 3W PANELS 6D-12 Shoring Table GENERAL INFORMATION Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span. ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 161 TABLE OF CONTENTS 7.10 6DF-24 6” 24” Panel Properties Gage Weight w psf 4.89 5.38 5.92 5.98 6.46 7.00 7.06 7.55 8.08 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Compression Gage Area Ae in2/ft 1.007 1.146 1.291 1.361 1.498 1.640 1.676 1.836 1.997 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Base Metal Thickness Yield Strength t Fy in ksi .0359/.036 33 .0359/.047 33 .0359/.059 33 .0478/.036 33 .0478/.047 33 .0478/.059 33 .0598/.036 33 .0598/.047 33 .0598/.059 33 Tensile Strength Fu ksi 45 45 45 45 45 45 45 45 45 Area Ag in2/ft 1.298 1.458 1.619 1.580 1.740 1.901 1.862 2.022 2.182 Effective Section Modulus at Fy Bending Section Modulus Se+ in3/ft 1.476 1.508 1.532 2.198 2.250 2.288 3.004 3.077 3.132 Distance to N.A. from Bottom yb in 2.07 1.84 1.65 2.48 2.24 2.05 2.78 2.56 2.38 Section Modulus Sein3/ft 1.709 2.208 2.357 2.094 2.593 3.133 3.546 3.005 3.575 20 End Interior 1" 194 197 Allowable (Rn/Ω) 2" 4" 256 414 230 314 18 End Interior 400 400 525 462 16 End Interior 674 675 14 End Interior 1141 1154 Condition Web Crippling Constraints 162 Radius of Gyration r in 2.596 2.567 2.523 2.602 2.601 2.582 2.593 2.608 2.605 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 3.92 3.56 3.22 4.00 3.73 3.46 4.01 3.81 3.60 Reactions at Supports (plf) Based on Web Crippling Beam Gage Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Ig yb Sg in4/ft in in3/ft 8.747 2.49 0.788 9.611 2.23 4.304 10.308 2.03 5.090 10.701 2.75 3.896 11.772 2.51 4.696 12.668 2.31 5.488 12.517 2.93 4.278 13.750 2.71 5.080 14.809 0.58 1.249 Moment of Inertia Ie+ in4/ft 6.676 7.232 7.671 9.065 9.882 10.556 11.405 12.462 13.361 Bearing Length of Webs Moment of Inertia I ein4/ft 6.693 7.856 8.948 8.371 9.671 10.951 10.069 11.457 12.870 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 7.366 8.025 8.550 9.611 10.512 11.260 11.776 12.891 13.844 Iin4/ft 7.378 8.441 9.401 9.148 10.371 11.524 10.885 12.221 13.516 8" 453 335 1" 290 301 Factored (ΦRn) 2" 4" 385 620 352 480 8" 680 512 839 617 954 674 600 612 788 707 1259 944 1431 1031 880 772 1394 1016 1582 1105 1011 1033 1319 1182 2091 1554 2373 1691 1478 1308 2319 1692 2628 1833 1711 1766 2216 2001 3479 2589 3941 2805 h=5.7" r=0.125" Composite and Non-Composite Deck Catalog • February 2016 θ=90º www.ascsd.com TABLE OF CONTENTS 3W PANELS Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) Gage Span Limit Condition fb / Ω L/360 L/240 fb / Ω 20/20 DS Φ fb L/360 L/240 fb / Ω L/360 L/240 fb / Ω SS Φ fb L/360 L/240 20/18 DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 fb / Ω SS Φ fb L/360 L/240 fb / Ω 20/16 DS L/360 L/240 fb / Ω TS Φ fb L/360 L/240 26' - 0" 28' - 0" 30' - 0" 194 309 135 214 99 157 76 121 60 95 49 77 40 64 34 54 29 46 25 39 22 34 - - - - 55 - 40 - 30 - 23 - 18 27 15 22 12 18 225 357 156 248 115 182 88 140 70 110 56 89 - - - - - - 199 315 138 219 101 161 78 123 61 97 50 79 41 65 34 55 29 47 25 40 22 35 - - - - 60 - 44 - 33 - 25 - 20 - 16 24 13 19 291 462 202 320 148 235 114 180 90 142 73 115 - - - - - - 202 320 140 222 103 163 79 125 62 99 50 80 42 66 35 56 30 47 26 41 22 36 - - - - - 47 - 35 - 27 - 21 - 17 26 14 21 310 493 216 342 158 251 121 192 96 152 78 123 - - - - - - Exceeds Maximum Product Length 281 447 - Exceeds Maximum Product Length 310 493 - 315 500 Exceeds Maximum Product Length D PANEL Φ fb 16' - 0" C PANELS L/240 14' - 0" N PANELS fb / Ω 12' - 0" B PANELS TS Φ fb 10' - 0" 2W PANELS SS Φ fb Panel Span (Support Spacing) 18' - 0" 20' - 0" 22' - 0" 24' - 0" GENERAL INFORMATION 6DF-24 7.11 ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 163 TABLE OF CONTENTS 7.11 6DF-24 Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) Gage Span Limit Condition fb / Ω SS Φ fb L/360 L/240 fb / Ω 18/20 DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω 18/18 DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω 18/16 DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 L/240 164 Panel Span (Support Spacing) 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 10' - 0" 12' - 0" 14' - 0" 26' - 0" 28' - 0" 30' - 0" 290 459 201 319 148 234 113 179 89 142 72 115 60 95 50 80 43 68 37 59 32 51 - - - 103 - 72 - 53 - 39 59 30 46 24 36 19 29 16 23 276 438 192 304 141 223 108 171 85 135 69 109 - - - - - - 296 470 206 327 151 240 116 184 91 145 74 118 61 97 51 82 44 70 38 60 33 52 - - - 112 - 79 - 57 - 43 - 33 50 26 39 21 31 17 26 342 542 237 376 174 276 133 212 105 167 85 135 - - - - - - 301 478 209 332 154 244 118 187 93 148 75 120 62 99 52 83 45 71 38 61 33 53 - - - - 84 - 62 - 46 - 36 - 28 42 22 34 18 27 413 655 287 455 211 334 161 256 127 202 103 164 - - - - - - Exceeds Maximum Product Length 345 547 - Exceeds Maximum Product Length 427 677 - 471 747 Exceeds Maximum Product Length - Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 3W PANELS Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) Gage Span Limit Condition fb / Ω SS L/360 L/240 fb / Ω 16/20 DS Φ fb L/360 L/240 fb / Ω L/360 L/240 fb / Ω SS Φ fb L/360 L/240 16/18 DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 SS Φ fb L/360 L/240 fb / Ω 16/16 DS L/360 L/240 fb / Ω TS Φ fb L/360 L/240 28' - 0" 30' - 0" 155 245 122 194 99 157 82 130 69 109 59 93 50 80 44 70 - - 188 - 126 - 88 - 64 96 48 72 37 56 29 44 23 35 19 29 467 741 324 515 238 378 182 289 144 229 117 185 - - - - - - 405 643 281 447 207 328 158 251 125 198 101 161 84 133 70 112 60 95 52 82 45 71 - - 205 - 138 - 97 - 70 - 53 79 41 61 32 48 26 38 21 31 396 628 275 436 202 320 155 245 122 194 99 157 - - - - - - 413 655 287 455 211 334 161 256 127 202 103 164 85 135 72 114 61 97 53 83 46 73 - - - 148 - 104 - 76 - 57 85 44 66 34 52 28 41 22 34 471 747 327 519 240 381 184 292 145 231 118 187 - - - - - - Exceeds Maximum Product Length 584 926 - Exceeds Maximum Product Length 495 785 - 589 934 Exceeds Maximum Product Length D PANEL Φ fb 26' - 0" 202 320 C PANELS L/240 fb / Ω 14' - 0" 275 436 N PANELS fb / Ω 12' - 0" 396 628 B PANELS TS Φ fb 10' - 0" 2W PANELS Φ fb Panel Span (Support Spacing) 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" GENERAL INFORMATION 6DF-24 7.11 ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 165 TABLE OF CONTENTS 7.12 6DF-24 Normal Weight Concrete (145 pcf) Maximum Unshored Spans 6DF-24 Shoring Table Total Slab Depth (in) Volume cy/100sf 7 1/2 0.937 8 1/2 1.246 9 1/2 1.554 10 1/2 1.863 11 1/2 2.171 Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 145 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 41.5 17' - 4" 18' - 8" 42.1 17' - 6" 19' - 11" 42.7 17' - 6" 20' - 0" 42.6 21' - 0" 20' - 0" 43.1 21' - 2" 20' - 0" 43.8 21' - 3" 20' - 0" 43.6 22' - 2" 20' - 0" 44.2 22' - 7" 20' - 0" 44.9 23' - 1" 20' - 0" 53.6 15' - 11" 17' - 2" 54.1 16' - 1" 18' - 4" 54.8 16' - 1" 18' - 5" 54.6 19' - 4" 18' - 10" 55.2 19' - 6" 20' - 0" 55.9 19' - 7" 20' - 0" 55.7 20' - 11" 20' - 0" 56.3 21' - 4" 20' - 0" 57.0 21' - 10" 20' - 0" 65.6 14' - 9" 15' - 11" 66.2 14' - 11" 17' - 0" 66.9 15' - 0" 17' - 1" 66.7 18' - 0" 17' - 6" 67.3 18' - 1" 19' - 5" 68.0 18' - 2" 20' - 0" 67.8 19' - 11" 20' - 0" 68.4 20' - 4" 20' - 0" 69.0 20' - 10" 20' - 0" 77.7 13' - 9" 14' - 11" 78.3 13' - 11" 16' - 0" 79.0 14' - 0" 16' - 1" 78.8 16' - 10" 16' - 6" 79.4 17' - 0" 18' - 3" 80.0 17' - 1" 19' - 6" 79.9 19' - 2" 20' - 0" 80.5 19' - 7" 19' - 7" 81.1 19' - 11" 20' - 0" 89.8 12' - 11" 14' - 2" 90.4 13' - 1" 15' - 1" 91.0 13' - 2" 15' - 2" 90.9 15' - 11" 15' - 7" 91.5 16' - 1" 17' - 3" 92.1 16' - 2" 18' - 6" 92.0 18' - 7" 20' - 0" 92.6 18' - 9" 18' - 6" 93.2 18' - 10" 20' - 0" Triple 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span. 166 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Light Weight Concrete (110 pcf) Maximum Unshored Spans 1.246 9 1/2 1.554 10 1/2 1.863 11 1/2 2.171 D PANEL 8 1/2 C PANELS 0.937 Triple 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" N PANELS 7 1/2 ACUSTADEK® Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 110 pcf Light Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 32.6 18' - 10" 20' - 0" 33.2 19' - 0" 20' - 0" 33.8 19' - 0" 20' - 0" 33.7 22' - 4" 20' - 0" 34.3 22' - 9" 20' - 0" 34.9 23' - 0" 20' - 0" 34.8 23' - 6" 20' - 0" 35.4 23' - 11" 20' - 0" 36.0 24' - 6" 20' - 0" 41.8 17' - 5" 18' - 9" 42.4 17' - 7" 20' - 0" 43.0 17' - 7" 20' - 0" 42.9 21' - 1" 20' - 0" 43.5 21' - 3" 20' - 0" 44.1 21' - 4" 20' - 0" 44.0 22' - 3" 20' - 0" 44.5 22' - 8" 20' - 0" 45.2 23' - 2" 20' - 0" 51.0 16' - 4" 17' - 7" 51.5 16' - 5" 18' - 9" 52.2 16' - 6" 18' - 10" 52.1 19' - 9" 19' - 4" 52.6 19' - 11" 20' - 0" 53.2 20' - 0" 20' - 0" 53.1 21' - 3" 20' - 0" 53.7 21' - 8" 20' - 0" 54.3 22' - 2" 20' - 0" 60.1 15' - 5" 16' - 7" 60.7 15' - 6" 17' - 8" 61.3 15' - 7" 17' - 9" 61.2 18' - 8" 18' - 2" 61.8 18' - 10" 20' - 0" 62.4 18' - 11" 20' - 0" 62.3 20' - 5" 20' - 0" 62.9 20' - 10" 20' - 0" 63.5 21' - 4" 20' - 0" 69.3 14' - 7" 15' - 8" 69.9 14' - 8" 16' - 9" 70.5 14' - 9" 16' - 10" 70.4 17' - 8" 17' - 3" 71.0 17' - 10" 19' - 2" 71.6 17' - 11" 20' - 0" 71.5 19' - 9" 20' - 0" 72.0 20' - 2" 20' - 0" 72.7 20' - 8" 20' - 0" B PANELS Volume cy/100sf 2W PANELS Total Slab Depth (in) 3W PANELS 6DF-24 Shoring Table Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span. www.ascsd.com GENERAL INFORMATION 6DF-24 7.12 Composite and Non-Composite Deck Catalog • February 2016 167 TABLE OF CONTENTS 7.13 7.5D-12 9” 7-1/2” 12” 2 Welds Panel Properties Gage Weight w psf 3.60 4.80 6.00 7.60 20 18 16 14 Compression Gage Area Ae in2/ft 0.519 0.816 1.154 1.661 20 18 16 14 Base Metal Thickness Yield Strength t Fy in ksi 0.0359 33 0.0478 33 0.0598 33 0.075 33 Tensile Strength Fu ksi 45 45 45 45 Area Ag in2/ft 1.058 1.414 1.768 2.235 Effective Section Modulus at Fy Bending Section Modulus Se+ in3/ft 1.718 2.702 3.454 4.440 Distance to N.A. from Bottom yb in 3.50 3.87 4.05 4.23 Section Modulus Sein3/ft 1.791 2.548 3.316 4.360 20 End Interior 1" 169 171 Allowable (Rn/Ω) 2" 4" 223 360 200 273 18 End Interior 361 361 474 417 16 End Interior 620 621 14 End Interior 1065 1077 Condition Web Crippling Constraints 168 Radius of Gyration r in 2.931 2.924 2.917 2.908 Effective Moment of Inertia for Deflection Distance to N.A. from Bottom yb in 4.60 4.47 4.38 4.29 Reactions at Supports (plf) Based on Web Crippling Beam Gage Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Ig yb Sg in4/ft in in3/ft 9.088 4.23 2.148 12.089 4.24 2.853 15.040 4.24 3.547 18.900 4.25 4.451 Moment of Inertia Ie+ in4/ft 6.863 10.457 14.003 18.778 Bearing Length of Webs Moment of Inertia I ein4/ft 8.231 11.389 14.524 18.700 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 7.605 11.001 14.349 18.819 Iin4/ft 8.517 11.622 14.696 18.767 8" 395 292 1" 253 262 Factored (ΦRn) 2" 4" 335 540 307 418 8" 592 446 757 557 861 608 541 552 711 638 1136 852 1291 931 809 710 1282 934 1455 1016 930 950 1213 1087 1923 1430 2182 1555 1380 1221 2166 1580 2453 1711 1598 1648 2069 1868 3248 2417 3680 2619 h=7.2" r=0.125" Composite and Non-Composite Deck Catalog • February 2016 θ=90º www.ascsd.com TABLE OF CONTENTS 7.5D-12 7.14 Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) Gage Span Limit Condition SS Φ fb L/360 L/240 fb / Ω 20 DS Φ fb L/360 fb / Ω TS Φ fb L/360 L/240 fb / Ω SS L/360 L/240 fb / Ω 18 DS Φ fb L/360 L/240 fb / Ω Φ fb L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 L/240 fb / Ω L/360 L/240 fb / Ω 14 DS Φ fb L/360 L/240 TS Φ fb L/360 L/240 www.ascsd.com 110 174 82 - 316 501 303 481 - 232 368 229 223 354 - 178 282 153 171 271 - 140 223 108 - 406 644 399 633 - 298 473 293 465 - 228 362 201 224 356 - 181 286 141 - 45 72 22 33 40 63 18 27 58 92 29 43 51 80 23 35 75 118 37 56 65 103 30 46 Exceeds Maximum Product Length 89 141 60 - 74 117 45 68 62 98 35 52 53 84 27 41 Exceeds Maximum Product Length 114 180 78 - 94 149 59 88 79 125 45 68 67 107 36 54 Exceeds Maximum Product Length 146 232 103 - 121 192 77 116 102 161 59 89 87 137 47 70 Exceeds Maximum Product Length Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® fb / Ω 139 221 117 131 208 - 30' - 0" 25 40 12 18 D PANEL SS Φ fb 182 288 175 171 272 - 28' - 0" 29 46 15 23 C PANELS 16 247 392 233 370 - 26' - 0" 33 53 19 28 N PANELS TS 16' - 0" 88 140 81 92 146 - B PANELS Φ fb 14' - 0" 115 183 120 191 - 2W PANELS L/240 Panel Span (Support Spacing) 18' - 0" 20' - 0" 22' - 0" 24' - 0" 70 57 47 39 111 90 74 62 57 42 31 24 36 12' - 0" 157 249 164 260 - 3W PANELS fb / Ω 10' - 0" 226 359 236 374 295 468 356 565 336 532 420 666 455 722 437 693 546 866 585 928 574 911 718 1139 - GENERAL INFORMATION 169 TABLE OF CONTENTS 7.15 7.5D-12 Normal Weight Concrete (145 pcf) Maximum Unshored Spans 7.5D-12 Shoring Table Total Slab Depth (in) Volume cy/100sf 9 1.042 9 1/2 1.196 10 1.350 10 1/2 1.505 11 1.659 11 1/2 1.813 12 1.968 12 1/2 2.122 13 2.276 Gage 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 145 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 44.4 18' - 4" 16' - 0" 45.6 21' - 9" 16' - 0" 46.8 23' - 1" 16' - 0" 48.4 24' - 6" 16' - 0" 50.4 17' - 7" 16' - 0" 51.6 21' - 1" 16' - 0" 52.8 22' - 5" 16' - 0" 54.4 23' - 10" 16' - 0" 56.5 16' - 11" 16' - 0" 57.7 20' - 7" 16' - 0" 58.9 21' - 10" 16' - 0" 60.5 23' - 3" 16' - 0" 62.5 16' - 3" 16' - 0" 63.7 20' - 1" 16' - 0" 64.9 21' - 4" 16' - 0" 66.5 22' - 9" 16' - 0" 68.5 15' - 9" 16' - 0" 69.7 19' - 7" 16' - 0" 70.9 20' - 11" 16' - 0" 72.5 22' - 3" 16' - 0" 74.6 15' - 3" 15' - 7" 75.8 19' - 0" 16' - 0" 77.0 20' - 6" 16' - 0" 78.6 21' - 10" 16' - 0" 80.6 14' - 9" 15' - 1" 81.8 18' - 5" 16' - 0" 83.0 20' - 2" 16' - 0" 84.6 21' - 5" 16' - 0" 86.7 14' - 4" 14' - 8" 87.9 17' - 11" 16' - 0" 89.1 19' - 10" 16' - 0" 90.7 21' - 1" 16' - 0" 92.7 13' - 11" 14' - 3" 93.9 17' - 5" 16' - 0" 95.1 19' - 6" 16' - 0" 96.7 20' - 9" 16' - 0" Triple 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span. 170 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 7.5D-12 7.15 Light Weight Concrete (110 pcf) Maximum Unshored Spans 9 1/2 1.196 10 1.350 10 1/2 1.505 11 1.659 11 1/2 1.813 12 1.968 12 1/2 2.122 13 2.276 C PANELS 1.042 Triple 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" N PANELS 9 D PANEL Gage 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 20 18 16 14 145 pcf Light Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 34.5 20' - 0" 16' - 0" 35.7 23' - 2" 16' - 0" 36.9 24' - 7" 16' - 0" 38.5 26' - 0" 16' - 0" 39.1 19' - 3" 16' - 0" 40.3 22' - 6" 16' - 0" 41.5 23' - 10" 16' - 0" 43.1 25' - 4" 16' - 0" 43.7 18' - 7" 16' - 0" 44.9 21' - 11" 16' - 0" 46.1 23' - 3" 16' - 0" 47.7 24' - 9" 16' - 0" 48.3 17' - 11" 16' - 0" 49.5 21' - 5" 16' - 0" 50.7 22' - 9" 16' - 0" 52.3 24' - 2" 16' - 0" 52.9 17' - 5" 16' - 0" 54.1 21' - 0" 16' - 0" 55.3 22' - 3" 16' - 0" 56.9 23' - 8" 16' - 0" 57.5 16' - 11" 16' - 0" 58.7 20' - 7" 16' - 0" 59.9 21' - 10" 16' - 0" 61.5 23' - 3" 16' - 0" 62.0 16' - 5" 16' - 0" 63.2 20' - 2" 16' - 0" 64.4 21' - 6" 16' - 0" 66.0 22' - 10" 16' - 0" 66.6 16' - 0" 16' - 0" 67.8 19' - 10" 16' - 0" 69.0 21' - 1" 16' - 0" 70.6 22' - 6" 16' - 0" 71.2 15' - 7" 15' - 11" 72.4 19' - 5" 16' - 0" 73.6 20' - 10" 16' - 0" 75.2 22' - 2" 16' - 0" B PANELS Volume cy/100sf 2W PANELS Total Slab Depth (in) 3W PANELS 4.5D-12 Shoring Table GENERAL INFORMATION Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span. ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 171 TABLE OF CONTENTS 7.16 7.5DF-24 7-1/2” 24” RD33 7-1/2” Deep Deck Cellular Panel Properties Gage Weight w psf 5.24 5.73 6.27 6.44 6.93 7.47 7.64 8.13 8.67 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Compression Gage Area Ae in2/ft 1.056 1.191 1.332 1.456 1.589 1.728 1.853 1.998 2.136 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 Base Metal Thickness Yield Strength t Fy in ksi .0359/.036 33 .0359/.047 33 .0359/.059 33 .0478/.036 33 .0478/.047 33 .0478/.059 33 .0598/.036 33 .0598/.047 33 .0598/.059 33 Tensile Strength Fu ksi 45 45 45 45 45 45 45 45 45 Area Ag in2/ft 1.403 1.563 1.724 1.721 1.881 2.042 2.039 2.199 2.359 Effective Section Modulus at Fy Bending Section Modulus Se+ in3/ft 1.821 2.048 2.087 2.936 3.017 3.078 3.977 4.087 4.172 Distance to N.A. from Bottom yb in 2.61 2.40 2.17 3.16 2.88 2.65 3.51 3.25 3.03 Section Modulus Sein3/ft 2.252 2.890 3.119 2.824 3.429 4.077 3.396 4.000 4.687 Condition Distance to N.A. from Bottom yb in 4.84 4.40 4.03 4.85 4.58 4.30 4.87 4.66 4.44 Moment of Inertia Ie+ in4/ft 10.687 11.874 12.639 14.741 16.088 17.215 18.505 20.203 21.667 Bearing Length of Webs Moment of Inertia I ein4/ft 10.905 12.701 14.417 13.702 15.694 17.683 16.533 18.647 20.823 Uniform Load Only Id = (2Ie+Ig)/3 I+ in4/ft 11.859 13.117 14.010 15.624 17.092 18.326 19.128 20.909 22.448 Iin4/ft 12.005 13.669 15.195 14.932 16.829 18.638 17.813 19.872 21.886 8" 395 292 1" 253 262 Factored (ΦRn) 2" 4" 335 540 307 418 8" 592 446 20 End Interior 1" 169 171 18 End Interior 361 361 474 417 757 557 861 608 541 552 711 638 1136 852 1291 931 16 End Interior 620 621 809 710 1282 934 1455 1016 930 950 1213 1087 1923 1430 2182 1555 14 End Interior 1065 1077 1380 1221 2166 1580 2453 1711 1598 1648 2069 1868 3248 2417 3680 2619 Web Crippling Constraints 172 Allowable (Rn/Ω) 2" 4" 223 360 200 273 Radius of Gyration r in 3.182 3.159 3.117 3.179 3.186 3.172 3.660 3.186 3.190 Effective Moment of Inertia for Deflection Reactions at Supports (plf) Based on Web Crippling Beam Gage Gross Section Properties Distance to Moment of N.A. from Section Inertia Bottom Modulus Ig yb Sg in4/ft in in3/ft 14.204 3.16 4.502 15.605 2.84 5.486 16.751 2.59 6.460 17.391 3.45 5.040 19.100 3.17 6.027 20.549 2.93 7.007 20.374 3.66 5.573 22.320 3.40 6.562 24.010 3.18 7.544 h=7.2" r=0.125" Composite and Non-Composite Deck Catalog • February 2016 θ=90º www.ascsd.com TABLE OF CONTENTS 7.5DF-24 7.17 Gage Span Limit Condition fb / Ω SS Φ fb L/360 fb / Ω 20/20 DS Φ fb L/360 L/240 fb / Ω L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω DS L/360 L/240 fb / Ω TS Φ fb L/360 L/240 SS Φ fb L/360 L/240 fb / Ω 20/16 DS Φ fb L/360 fb / Ω TS Φ fb L/360 28' - 0" 30' - 0" 240 381 167 264 122 194 94 149 74 117 60 95 50 79 42 66 35 56 31 49 27 42 - - - - - - 49 - 37 - 29 - 24 - 19 - 297 471 206 327 151 240 116 184 92 145 74 118 - - - - - - 270 428 187 297 138 218 105 167 83 132 67 107 56 88 47 74 40 63 34 55 30 48 - - - - - - 54 - 41 - 33 - 26 - 21 - 381 604 264 419 194 308 149 236 118 186 95 151 - - - - - - 275 436 191 303 140 223 107 170 85 135 69 109 57 90 48 76 41 65 35 56 31 48 - - - - - - - 44 - 35 - 28 - 23 - 411 652 285 453 210 333 161 255 127 201 103 163 - - - - - - Exceeds Maximum Product Length 371 588 - Exceeds Maximum Product Length 422 669 - 430 682 Exceeds Maximum Product Length D PANEL L/240 26' - 0" C PANELS fb / Ω 16' - 0" N PANELS 20/18 Φ fb 14' - 0" B PANELS TS Φ fb 12' - 0" 2W PANELS L/240 Panel Span (Support Spacing) 18' - 0" 20' - 0" 22' - 0" 24' - 0" 10' - 0" 3W PANELS Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) GENERAL INFORMATION - ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 173 TABLE OF CONTENTS 7.17 7.5DF-24 Normal Weight Concrete (145 pcf) Maximum Unshored Spans Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) Gage Span Limit Condition fb / Ω SS Φ fb L/360 L/240 fb / Ω 18/20 DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω 18/18 DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 L/240 fb / Ω SS Φ fb L/360 L/240 fb / Ω 18/16 DS Φ fb L/360 L/240 fb / Ω TS 174 Φ fb L/360 Panel Span (Support Spacing) 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 10' - 0" 12' - 0" 14' - 0" 26' - 0" 28' - 0" 30' - 0" 387 614 269 426 197 313 151 240 119 189 97 153 80 127 67 107 57 91 49 78 43 68 - - - - 117 - 85 - 64 - 49 - 39 - 31 47 25 38 372 590 258 410 190 301 145 231 115 182 93 148 - - - - - - 397 631 276 438 203 322 155 246 123 195 99 158 82 130 69 109 59 93 51 80 44 70 - - - - - 93 - 70 - 54 - 43 - 34 - 28 41 452 717 314 498 230 366 176 280 139 221 113 179 - - - - - - 406 643 282 447 207 328 158 251 125 199 101 161 84 133 70 112 60 95 52 82 45 71 - - - - - 100 - 75 - 58 - 46 - 36 - 30 44 537 852 373 592 274 435 210 333 166 263 134 213 - - - - - - Exceeds Maximum Product Length 465 738 - Exceeds Maximum Product Length 565 896 - 634 1005 Exceeds Maximum Product Length - Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 7.5DF-24 7.17 Light Weight Concrete (110 pcf) Maximum Unshored Spans 3W PANELS Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2) Gage Span Limit Condition fb / Ω SS L/360 L/240 fb / Ω 16/20 DS Φ fb L/360 L/240 fb / Ω L/360 L/240 fb / Ω SS Φ fb L/360 L/240 16/18 DS Φ fb L/360 L/240 fb / Ω TS Φ fb L/360 SS Φ fb L/360 L/240 fb / Ω 16/16 DS L/360 L/240 fb / Ω TS Φ fb L/360 28' - 0" 30' - 0" 205 325 162 257 131 208 108 172 91 144 77 123 67 106 58 92 - - - 204 - 143 - 104 - 79 - 60 91 48 71 38 57 31 46 447 710 311 493 228 362 175 277 138 219 112 177 - - - - - - 538 854 374 593 275 436 210 334 166 264 135 214 111 176 93 148 80 126 69 109 60 95 - - - - 157 - 114 - 86 - 66 - 52 78 42 62 34 51 527 836 366 581 269 426 206 327 163 258 132 209 - - - - - - 550 872 382 606 280 445 215 341 170 269 137 218 114 180 95 151 81 129 70 111 61 97 - - - - 168 - 123 - 92 - 71 - 56 - 45 67 36 55 617 979 429 680 315 500 241 383 191 302 154 245 - - - - - - Exceeds Maximum Product Length 559 887 - Exceeds Maximum Product Length 659 1045 - 772 1224 Exceeds Maximum Product Length D PANEL Φ fb 26' - 0" 267 424 C PANELS L/240 fb / Ω 14' - 0" 364 577 N PANELS fb / Ω 12' - 0" 524 831 B PANELS TS Φ fb 10' - 0" 2W PANELS Φ fb Panel Span (Support Spacing) 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" GENERAL INFORMATION ACUSTADEK® www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 175 TABLE OF CONTENTS 7.18 7.5DF-24 Normal Weight Concrete (145 pcf) Maximum Unshored Spans 7.5DF-24 Shoring Table Total Slab Depth (in) Volume cy/100sf 9 1.053 10 1.361 11 1.670 12 1.979 13 2.287 Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 145 pcf Normal Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 46.3 18' - 7" 20' - 0" 46.9 19' - 8" 20' - 0" 47.6 19' - 9" 20' - 0" 47.6 23' - 5" 20' - 0" 48.1 23' - 8" 20' - 0" 48.8 23' - 9" 20' - 0" 48.8 24' - 7" 20' - 0" 49.3 25' - 1" 20' - 0" 50.0 25' - 5" 20' - 0" 58.4 17' - 2" 19' - 1" 59.0 18' - 2" 20' - 0" 59.7 18' - 3" 20' - 0" 59.6 21' - 8" 20' - 0" 60.2 21' - 10" 20' - 0" 60.9 22' - 0" 20' - 0" 60.8 23' - 4" 20' - 0" 61.4 23' - 9" 20' - 0" 62.1 24' - 2" 20' - 0" 70.5 16' - 0" 17' - 10" 71.1 16' - 11" 19' - 4" 71.7 17' - 0" 19' - 5" 71.7 20' - 2" 19' - 10" 72.3 20' - 5" 20' - 0" 72.9 20' - 7" 20' - 0" 72.9 22' - 4" 20' - 0" 73.5 22' - 9" 20' - 0" 74.1 23' - 2" 20' - 0" 82.6 15' - 1" 16' - 9" 83.2 15' - 11" 18' - 2" 83.8 16' - 1" 18' - 4" 83.8 19' - 0" 18' - 8" 84.4 19' - 3" 20' - 0" 85.0 19' - 4" 20' - 0" 85.0 21' - 6" 20' - 0" 85.6 21' - 11" 20' - 0" 86.2 22' - 4" 20' - 0" 94.7 14' - 3" 15' - 11" 95.3 15' - 1" 17' - 3" 95.9 15' - 2" 17' - 4" 95.9 18' - 0" 17' - 8" 96.5 18' - 3" 19' - 5" 96.5 18' - 3" 19' - 5" 97.1 20' - 10" 19' - 4" 97.7 21' - 1" 20' - 0" 98.3 21' - 3" 20' - 0" Triple 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span. 176 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS 7.5DF-24 7.18 Light Weight Concrete (110 pcf) Maximum Unshored Spans 1.361 11 1.670 12 1.979 13 2.287 D PANEL 10 C PANELS 1.053 Triple 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" N PANELS 9 ACUSTADEK® Gage 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 20/20 20/18 20/16 18/20 18/18 18/16 16/20 16/18 16/16 145 pcf Light Weight Concrete Maximum Unshored Span Slab and Deck psf Single Double 36.4 20' - 4" 20' - 0" 37.0 21' - 5" 20' - 0" 37.6 21' - 7" 20' - 0" 37.6 25' - 0" 20' - 0" 38.2 25' - 5" 20' - 0" 38.8 25' - 9" 20' - 0" 38.8 26' - 1" 20' - 0" 39.4 26' - 7" 20' - 0" 40.0 26' - 11" 20' - 0" 45.6 18' - 10" 20' - 0" 46.2 19' - 11" 20' - 0" 46.8 20' - 0" 20' - 0" 46.8 23' - 8" 20' - 0" 47.4 23' - 11" 20' - 0" 48.0 24' - 1" 20' - 0" 48.0 24' - 9" 20' - 0" 48.6 25' - 3" 20' - 0" 49.2 25' - 8" 20' - 0" 54.8 17' - 8" 19' - 8" 55.3 18' - 8" 20' - 0" 55.9 18' - 9" 20' - 0" 56.0 22' - 3" 20' - 0" 56.5 22' - 6" 20' - 0" 57.1 22' - 8" 20' - 0" 57.2 23' - 9" 20' - 0" 57.7 24' - 3" 20' - 0" 58.3 24' - 7" 20' - 0" 63.9 16' - 9" 18' - 7" 64.5 17' - 8" 20' - 0" 65.1 17' - 9" 20' - 0" 65.1 21' - 1" 20' - 0" 65.7 21' - 3" 20' - 0" 66.3 21' - 5" 20' - 0" 66.3 22' - 11" 20' - 0" 66.9 23' - 5" 20' - 0" 67.5 23' - 9" 20' - 0" 73.1 15' - 11" 17' - 8" 73.7 16' - 10" 19' - 2" 74.3 16' - 11" 19' - 3" 74.3 20' - 0" 19' - 8" 74.9 20' - 3" 20' - 0" 75.5 20' - 5" 20' - 0" 75.5 22' - 2" 20' - 0" 76.1 22' - 8" 20' - 0" 76.7 23' - 0" 20' - 0" B PANELS Volume cy/100sf 2W PANELS Total Slab Depth (in) 3W PANELS 7.5DF-24 Shoring Table Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span. www.ascsd.com GENERAL INFORMATION Composite and Non-Composite Deck Catalog • February 2016 177 TABLE OF CONTENTS 8.1 Acustadek® Acustadek® Acustadek provides the extraordinary beauty of exposed steel, while providing the same noise reduction performance of common Mineral Fiber, Fiberglass, and Bio Acoustic ceiling tile systems. It is an excellent option for reducing noise inside buildings, increasing the comfort for the occupants. Acustadek is a dual-purpose panel which helps lower costs by providing an interior finish while contributing to the structural performance of the building. This is accomplished by perforating the structural steel deck and adding fiberglass batt acoustic media in the webs or in the cells of cellular deck, turning the profile into Acustadek. Our new Smooth Series™ rivets offer a clean attachment solution for the Acustadek cellular deck system. Cellular Acustadek® Cellular Acustadek has 0.157” diameter holes spaced 0.433” inches on center in the sections of the pan below the top flutes of the steel deck. Fiberglass batts are factory inserted in the cells of the deck before shipping to the project locations. Any roof system utilizing structural or insulating concrete fill, rigid insulation board, or other roof substrate material suitable for installation on a steel roof deck may be applied to the cellular Acustadek. The sound absorption coefficient varies across the spectrum of audible sound. In buildings with equipment which creates a specific frequency, the sound absorption coefficient for that frequency range should determine the type of deck rather than the overall NRC rating. The NRC should not be confused with the Sound Transmission Coefficient (STC). STCs measure the blocking of sound through an assembly as it relates to the decibel drop in the intensity of the sound. Acustadek may not be a good choice if a high STC is required. As an example, consider a room with noisy equipment. The Acustadek may be a good solution to reduce the noise level in the room for the occupants, but may not be a good material to block the noise from escaping the room. The holes in the perforated Acustadek may in fact let more sound escape the room than a conventional deck. Detailing and Installation of Acustadek® Acustadek provides an exposed finish in the building. Steel deck is a structural element in the building and is subject to incidental dents in the handling and steel erection process. To minimize the potential damage use 20 gage or heavier. 22 gage may be an economical option when minor dents can be tolerated; dark paint finishes or high roof structures can mask these types of minor blemishes. Acustadek can be specified with a galvanized finish or factory prime painted over galvanized steel. Most Acustadeks will receive finish paint to meet the aesthetic requirements of the building. The galvanized steel can be field painted following the paint manufacturer’s preparation and application recommendations. As an option, factory-applied primer can be specified, which may reduce the surface preparation of the deck. Fiberglass Batts Fiberglass batts are used to absorb sound in the Acustadek assemblies. ASC Steel Deck supplies the fiberglass batts which are cut to size for the specified profile. The standard batts are unfaced. Optional batts encapsulated with 0.75 mil clear pvc plastic can be specified. Acoustical Performance All Acustadeks have been tested for the sound absorption characteristics of the assemblies. This is commonly presented as a Noise Reduction Coefficient (NRC). The NRC is the average of the 250, 500, 1000, and 2000 hertz sound absorption coefficients. Acustadeks have between a 0.6 and 1.0 NRC. Acustadek should be a portion of a holistic approach to reducing the noise level in a building. Simply specifying an NRC rating for a single material may not get the level of sound control you require. In general, steel deck tend to have better sound absorption coefficients in the higher audible range. Other materials such as fabric wall treatments and carpet tend to have better sound absorption coefficients in the lower audible frequency ranges. The use of Acustadek in combination with other materials may create the best overall quiet environment. An experienced acoustic designer is key to developing the best overall performance using ASC Steel Deck Acustadek products. 178 Attaching the Acustadek to the structure and connection of the side laps of the deck can impact the appearance of the installed product. Side lap top seam welds will leave burn marks on the galvanized finish and an occasional burn through should be expected. This may be unsightly if the galvanized finish is intended to be left exposed. The burns can be easily cleaned up prior to prime painting the deck after installation. A better solution, however, is to use the DeltaGrip® side lap connection. This mechanical interlock connection provides high strength similar to a weld without any thermal damage to the deck or galvanized coating, and is not visible from the underside of the deck. Arc spot and arc seam welds may also leave visible burn marks on the deck near the support or on the underside of the supporting steel. A good alternative to welding the deck to supports is to attach the deck with selfdrilling screws or power-actuated fasteners (PAF), such as the high shear nails manufactured by Hilti, Inc. or fasteners manufactured by Pneutek Inc. which are intended for decking applications. Structural Performance of Acustadek® The Acustadek perforations have a small impact on the structural performance of the deck profiles. Section properties are reduced from the non-Acustadek version of the profiles leading to reduced vertical load capacity. The reactions at supports are unaffected by the perforations in the Acustadek. Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Sound Absorption Data Absorption Coefficient1 Acustadek® Profile (Perforation Type) 1000 Hz 2000 Hz 4000 Hz Noise Reduction Coefficient1 125 Hz 250 Hz 500 Hz Unfaced 0.20 0.45 0.77 1.09 0.84 0.56 0.80 Encapsulated 0.16 0.37 0.70 1.01 0.64 0.49 0.70 Unfaced 0.44 0.57 1.08 1.00 0.82 0.63 0.85 Encapsulated 0.49 0.63 1.17 0.93 0.72 0.48 0.85 Unfaced 0.43 0.49 0.80 0.86 0.67 0.56 0.70 Encapsulated 0.38 0.42 0.79 0.79 0.48 0.41 0.60 Unfaced 0.58 0.53 0.98 0.85 0.66 0.52 0.75 Encapsulated 0.60 0.79 0.66 0.50 0.46 0.46 0.60 Unfaced 0.40 0.75 0.83 0.68 0.70 0.54 0.75 Encapsulated 0.58 0.91 0.93 0.68 0.59 0.46 0.80 Unfaced 0.40 0.89 0.85 0.72 0.70 0.53 0.80 Encapsulated 0.53 0.88 0.82 0.70 0.63 0.52 0.75 Unfaced 0.78 0.99 0.86 0.79 0.72 0.52 0.85 Encapsulated 0.84 0.93 0.79 0.75 0.65 0.93 0.80 3W PANELS Batt 2 GENERAL INFORMATION Acustadek® 8.2 BHF-36A 5″ 2W PANELS NHF-32A B PANELS 2WHF-36A 3WxHF-36A N PANELS 4.5DF-24A C PANELS 6DF-24A D PANEL 7.5DF-24A www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 ACUSTADEK® Table Notes: 1. Noise reduction coefficient testing was conducted in accordance with ASTM C423 and ASTM E795. 2. Unfaced or encapsulated fiberglass batts wrapped with clear plastic film. 179 TABLE OF CONTENTS Metric Conversion Chart Metric Conversions Spans, length & thickness Multiply By To Obtain Inches 25.4 Millimeters Feet 304.8 Millimeters Inches 0.0254 Metres Feet 0.3048 Metres psf 0.0479 kPa psi 6.8948 kPa Square feet 0.0929 Square Metre Square 9.2903 Square Metre Diaphragm Shear plf 0.0146 KN/m Section Properties in3/ft 53,763 mm3/m in /ft 1,365,588 mm4/m in3/ft 53.763 cm3/m in4/ft 136.559 cm4/m Pounds 0.00445 kN psf 4.8824 kg/m2 pcf 16.018 kg/m3 Vertical Load & Superimposed Load Area 4 Weight Volume 180 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com TABLE OF CONTENTS Evolution of Company ASC Steel Deck has provided structural steel roof and floor deck throughout the Western United States since the 1970s. Over this time, ASC Steel Deck has undergone a few ownership changes and operated under different business names (ASC Pacific, BHP Steel Building Products, and IMSA Building Products). Since 2002, however, we have operated under the name ASC Steel Deck, a division of ASC Profiles LLC. While the name of the company has changed over the years, the continuous dedication to product innovation, high quality steel deck products, and customer service has positioned ASC Steel Deck as a leader in the industry. Industry Innovator With an outward focus on the steel deck industry, ASC Steel Deck has led the way and established itself as a leader having accomplished many industry-firsts. ASC Steel Deck was the first West Coast manufacturer to incorporate diaphragm Shear and superimposed load tables based on ANSI/SDI C-2011 Standard for Composite Steel Floor DeckSlabs. This standard has been adopted for inclusion in the 2015 IBC. ASC Steel Deck has also led the way in providing innovative products which reduce installation costs, while offering some of the highest diaphragm shear values in the market. For example: • 36/7/4 Attachment Pattern - reduces attachment requirements for 11⁄2" roof deck by up to 30%. • N-32® Roof Deck - A 3" deep roof deck profile providing a 10% improvement in steel utilization and up to 20% reduction in installation costs as compared to the industry standard N-24 panel. Whether through product re-engineering or new product development, ASC Steel Deck strives for constant improvement through innovation. TABLE OF CONTENTS Manufacturing Facilities ASC Steel Deck • Sacramento, CA 2110 Enterprise Boulevard West Sacramento, CA 95691 916-372-6851 800-726-2727 ASC Steel Deck • Fontana, CA 10905 Beech Avenue Fontana, CA 92337 Visit us at: www.ascsd.com ©2016 ASC Profiles LLC All trademarks are the property of their respective owners. All rights reserved. Version 1.0 0216 Pub February 2016 (DL021)