pocket guide - AO Smith Water Heaters
Transcription
pocket guide - AO Smith Water Heaters
FULL PRODUCT LINE POCKET GUIDE RESIDENTIAL & COMMERCIAL The story is all in the details. Every water heater that carries the A. O. Smith name has a reputation to live up to, one that we’ve earned through 140 years of innovation. As an industry leader, we constantly look for new materials and develop new technologies that can improve energy efficiency. So, when you choose an A. O. Smith water heater, whether it’s gas, electric or hybrid you can be confident that you are getting the best water heating solution regardless of the application —for today and for years to come. Innovation has a name... A. O. Smith. All A. O. Smith residential water heaters meet the Federal Energy Efficiency Standards effective April 16, 2015, according to the National Appliance Energy Conservation Act (NAECA) of 1992 and meet the thermal efficiency and standby loss requirements of the U. S. Department of Energy and current edition of ASHRAE/IESNA 90.1. They also comply with the current edition of ICC Codes and the HUD Standards. Gas models meet American National Standards Institute Standards (ANSI Z21.10.3 - CSA 4.1) governing storage-type water heaters. Electric models are UL listed according to safety specifications outlined in Underwriters Laboratories, Inc. Standards for Safety (UL 174). RESIDENTIAL TABLE OF CONTENTS COMMERCIAL TABLE OF CONTENTS NAECA III Transition...........................................................................1 REMOTE MONITORING SYSTEM Contractor Rewards Program™..........................................................2 iCOMM™ and iCOMM™ Elite......................................................62-63 Product Comparison Guide................................................................3 BUILDING MANAGEMENT SYSTEM RESIDENTIAL GAS BACnet and Modbus Interface....................................................64-65 Vertex™ High Efficiency Power Vent................................................4-5 COMMERCIAL GAS AND OIL FIRED Vertex™ High Efficiency Power Direct Vent......................................6-7 Cyclone® HE BTX-80...................................................................66-67 Non-Condensing Power Vent..........................................................8-9 Cyclone® Xi BTX-100...................................................................68-69 Non-Condensing Power Direct Vent............................................10-11 Cyclone® Xi BTXL-100.................................................................70-71 ProMax® Direct Vent...................................................................12-13 Cyclone® MXi..............................................................................72-75 Effex High Efficiency Atmospheric Vent.....................................14-15 Master-Fit® BTR...........................................................................76-79 High Efficiency Non-Condensing Flue Damper............................16-17 Master-Fit® BTR Booster ............................................................80-81 ® ProMax Atmospheric Vent.........................................................18-21 Master-Fit® Ultra-Low NOx.........................................................82-85 ProMax® High Recovery Atmospheric Vent Conservationist® BT....................................................................86-87 75 & 100 Gallon..........................................................................22-23 Induced Draft Low NOx BTN Power Vent....................................88-89 Energy Saver Atmospheric Vent...................................................24-25 Conservationist® Power Vent......................................................90-91 Energy Saver Direct Vent ............................................................26-27 Conservationist® Power Direct Vent............................................92-93 ProMax® Ultra-Low NOx.............................................................28-29 Conservationist® Ultra-Low NOx.................................................94-95 High Efficiency Non-Condensing Power Burner Light-Duty.............................................................96-97 Ultra-Low NOx Power Vent.........................................................30-31 Low NOx Power Burner...............................................................98-99 ProMax® Ultra-Low NOx Direct Vent...........................................32-33 Conservationist® High Volume Power Burner..........................100-103 ProMax® Ultra-Low NOx High Recovery.....................................34-35 Conservationist® Duraclad Oil-Fired Tank-Type........................104-105 RESIDENTIAL TANKLESS Custom Heavy-Duty Large Volume Oil-Fired............................106-109 Tankless Condensing High Efficiency..........................................36-37 COMMERCIAL TANKLESS ® Tankless Condensing High Efficiency..........................................38-39 Tankless Non-Condensing.......................................................110-111 Tankless Non-Condensing...........................................................40-41 Tankless Non-Condensing Ultra-Low NOx..............................112-113 Tankless Non-Condensing Ultra-Low NOx..................................42-43 Tankless Condensing High Efficiency......................................114-115 RESIDENTIAL HYBRID ELECTRIC Tankless Heavy-Duty...............................................................116-117 Voltex® Hybrid Electric Heat Pump - 10-Year Warranty...............44-45 COMMERCIAL ELECTRIC Voltex® Legacy Hybrid Electric Heat Pump..................................46-47 DEN/DEL Electric Dura-Power™...............................................118-119 Voltex Hybrid Electric Heat Pump - 6-Year Warranty.................48-49 Gold Xi Series - DVE Electric...................................................120-121 RESIDENTIAL ELECTRIC Gold Series - DRE Electric........................................................122-123 Conservationist Self-Cleaning.....................................................50-51 Heavy-Duty Custom Xi............................................................124-125 ProMax® Standard......................................................................52-53 Heavy-Duty CMC/SU Booster Electric Dura-Power™................126-127 ProMax® Mobile Home...............................................................54-55 Air-To-Water Electric Heat Pumps ..........................................128-129 ProMax® Specialty......................................................................56-57 Heavy-Duty Premium Electric DVE/DHE Dura-Power™ ............130-133 RESIDENTIAL PUMP AND EXPANSION TANKS XP Domestic Water Heaters ...................................................134-137 ® Pump Tanks.................................................................................58-59 Expansion Tanks .........................................................................60-61 COMMERCIAL TABLE OF CONTENTS COMMERCIAL WATER HEATERS Burkay®Genesis® Domestic Water Heater...............................138-139 GUIDING YOU THROUGH Variable Fire™ High Efficiency Water Heater...........................140-141 THE NAECA III TRANSITION HOT WATER SUPPLY BOILERS Burkay® Energy Saver Copper Heat Exchanger......................142-143 Burkay® HW Gas Domestic Water Heaters & Boiler................144-145 COMMERCIAL ELECTRIC BOILERS Dura-Power™ NW Electric Boiler.............................................146-149 HOT WATER GENERATOR Steam or Boiler Hot Water HWG Generator Systems .............150-151 COMMERCIAL STORAGE TANKS Standard Jacketed Storage Tank.............................................152-153 Custom-Line Factory Jacketed & Insulated Storage Tank.......................................................154-155 Uninsulated Standard Stock Bare Storage Tank.....................156-157 Heavy-Duty Large Volume Storage Tanks Model HD Custom Built.........................................................158-161 COMMERCIAL WATER HEATERS The U.S. Department of Energy (DOE) regulates minimum energy efficiency requirements for all brands of water heaters. A new update to the rules for increasing minimum energy efficiency is in effect as of April 16, 2015. AT A. O. SMITH, WE’VE PREPARED OUR LINE OF RESIDENTIAL WATER HEATERS TO MEET THE STANDARDS. BUT AS SOMEONE IN THE BUILDING COMMUNITY, YOU NEED TO UNDERSTAND HOW THESE CHANGES IMPACT YOU AS WELL. These design changes require that most residential water heaters under 55 gallons of capacity produced after April 16, 2015 be larger in size. Therefore, they will require more installation space in both single-family and multi-family housing. Most water heaters under 55 gallons are 2˝ larger in height and diameter. Units over 55 gallons will require even more drastic technology changes. WATER HEATER REPLACEMENT ISSUES? WE HAVE SOLUTIONS. AC-U-Temp Complete Hot Water Systems.....................................162 OPTION 2: Upgrade to a smaller more efficient tankless unit. THE TECHNOLOGY FOR UNITS OVER 55 GALLONS HAS CHANGED. MORE OPTION 1: Upgrade to one of A. O . Smith’s High Efficiency THAN Options such as tankless or Vertex®. 55 GALLON OPTION 2: Replace your obsolete model with 2 smaller gas heaters. (Example: two 40-gallon gas units in the place of one 75-gallon gas unit). ELECTRIC Semi-Instantaneous HWI Water Heaters.......................................163 GAS INSTANTANEOUS WILL THE NEW LARGER DESIGN FIT? IF NOT, YOU HAVE TWO OPTIONS. LESS OPTION 1: Use a smaller heater to match the current footprint of THAN your existing heater. You might consider adding a mixing valve on 55 GALLON the water heater to increase delivery capacity. WILL THE NEW LARGER DESIGN FIT? IF NOT,SEE LESS BELOW. THAN OPTION 1: Use a smaller heater to match the current footprint 55 GALLON of your existing heater. You might consider adding a mixing valve on the water heater to increase delivery capacity. THE TECHNOLOGY FOR UNITS OVER 55 GALLONS HAS CHANGED. MORE OPTION 1: Upgrade to A. O. Smith’s Voltex® Hybrid Electric THAN Heat Pump water heater which is 2.5x more efficient as a standard 55 GALLON electric. OPTION 2: Replace your obsolete model with 2 smaller electric heaters (Example: Two 40-gallon electrics in the place of one 80-gallon electric). TO LEARN MORE, VISIT HOTWATER.COM/NAECA WHY PROFESSIONALS A. O. SMITH WATER HEATERS CHOOSE A. O. SMITH Contractor Rewards Program Brand Support It’s free and easy to participate. Enroll online at contractorrewards.com. Eligible products will have a yellow reward code label worth valuable points. Two ways to enter the codes: Profitable Contractors Contractor Tools & Support PREMIUM FEATURES. NAECA III READY. EARN POINTS BY PURCHASING A. O. SMITH WATER HEATERS Contractor Locator Breadth of Product Line 1. Download the smart phone app and scan the code. 2. Enter the code at contractorrewards.com. Redeem your points on thousands of reward items. Advertising Resources PROMAX PROMAX ® ® CONSERVATIONIST CONSERVATIONIST CONSERVATIONIST CONSERVATIONIST PREFERREDPREFERRED PROMAX CONSERVATIONIST CONSERVATIONIST PREFERRED B E S TB E S T ® ® ® ® G O O DG O O D ® ® BETTE BR ETTER GOOD ® BETTER BEST OPERATING COST CONSERVATIONALIST CONSERVATIONALIST CONSERVATIONIST CONSERVATIONIST PREFERREDPREFERRED $$$$$ PROMAX CONSERVATIONALIST CONSERVATIONIST$ PREFERRED PROMAX® PROMAX® ® G O O D G O O D INSTALLATION SPACE REQUIRED n n ® ® B E T TB EE RT T E R G O O D ® ® ® ® B E S TB E S T B E T T E R n to n n B E S T n to n n n HOT WATER OUTPUT ® ® CONSERVATIONALIST CONSERVATIONALIST ® CONSERVATIONALIST CONSERVATIONALIST ® P R E F E®PRRREEFDE R R E D CONSERVATIONALIST CONSERVATIONALIST PREFERRED ® PROMAX® PROMAX® PROMAX PREMIUM FEATURES: B E S TB E S T Blue Diamond® PROMAX PROMAX Glass Coating** • ® WITH OVER 1,000,000 MERCHANDISE ITEMS,YOUR REWARD CHOICES ARE ENDLESS. Dynaclean™ Automatic Sediment-Cleaning System** A. O. SMITH PROVIDES 6 KEY THINGS Heat Trap Nipples** TO HELP GROW YOUR BUSINESS & BECOME MORE PROFITABLE 1. Contractor Locator A new online locator that drives thousands of consumers from our website right to our loyal contractors. Your company listing is free and generated for you when you participate in our Contractor Rewards™ program.* Visit hotwater.com/ contractorlocator for more information. 2. Contractor Rewards Program Our program rewards our loyal contractors for buying our products. Buy more and get rewarded with prizes and higher status on our Contractor Locator. 3. Contractor Advertising Tools Our Advertising Resource Center allows contractors to develop an easy, affordable and custom advertising campaign to promote their business. Go to www.hotwater. com/ads. 4. Breadth of Product Line Residential or Commercial, we have the most complete line from Standard models to the most innovative high efficiency water heaters available. Self-Powered Electronic Gas Valve* Enhanced Flow Brass Drain Valve** Coregard™ Advanced Anode Rod Protection** Energy Saving ® ★ G O O ★DG★ O O D ★ • B E T TBEERT T E R B E S T • • ® B E S TB E S T B E T T E R B E S T • • ® ® CONSERVATIONALIST CONSERVATIONALIST ® CONSERVATIONALIST CONSERVATIONALIST P R E F E®PRRREEFDE R R E D CONSERVATIONALIST PROMAX® CONSERVATIONALIST PREFERRED ★ B E T T★E BR E★T T E R ★ ★G O O D★ ® ★ B E S★TB★ E S T ★ ★BETTER★ ® ★B E S T★ • • • • • • • • • • • • • • • • • • • Meets NAECA minimums Electronic User Interface Condensing Combustion* Continuous Flow* Cutting Edge Technology Industry Leading Efficiency Applies to some products only *These features apply to gas products only **These features apply to tank-type products only Hot Water Output, Cost of Operation, & Installation Space Required estimated based on typical applications/installations. For a more custom analysis of unique installations, visit www.hotwater.com and use our product selector tool. 5. Product Sales Tools We provide contractors access to the sales tools needed to close more sales. 6. Brand Support Marketing investment in our brands drive consumers to recognize our name, visit our websites, locate local contractors and request products. *To be listed on the Contractor Locator you must meet the minimum threshold of codes entered at contractorrewards.com 2 Visit hotwater.com/contractor to learn more. www.hotwater.com 3 RESIDENTIAL GAS T & P VALVE SIDE OUTLET H VERTEX™ HIGH EFFICIENCY POWER VENT ANODE Power Vent Design for Installation Versatility • Modular blower, with 120 volt, 60Hz electrical system (5 amps orA less), 6-foot cord with standard 3-prong connector. G HOT B DIAMETER • Combined horizontal and vertical vent runs terminating through an outside wall, using Schedule 40 PVC pipe as follows: SIDE INLET K COLD J C TOP VIEW • 2” pipe allows vent runs up to 25 equivalent feet. • 3” pipe allows vent runs up toT65 equivalent feet. HERMOSTAT • 4” pipe allows vent runs up to 128 equivalent feet. * INSTALL IN ACCORDANCE WITH LOCAL CODES DRAIN VALVE Side-Mounted Taps for Recirculating F Systems • Hot and cold “side taps” allow Vertex Power Vent to be used for “combination” systems for water heating plus space heating, radiant floor heatingFRONT or other VIEW applications requiring a recirculating hot water loop. D OUTLET INLET E SIDE OUTLET T & P VALVE Intelli-vent™* Gas Control with Silicon Nitride Hot Surface Ignitor AN • Premium-grade hot surface ignitor eliminates standing pilot. • Electronic circuitry provides superior system diagnostics capabilities plus extremely precise temperature control. Blue Diamond® Glass Coating with Two Heavy Duty Anode Rods A B G DIAMETER • Provides superior corrosion resistance compared to the industry-standard glass lining. THERMOSTAT • Patented eco-friendly burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J. Dynaclean™ Diffuser Dip Tube 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. 4 *Intelli-Vent™ is a registered trademark of Emerson Electric Company D E FRONT VIEW Maximum Hydrostatic Working Pressure:150 PSI • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. * INSTALL DRAIN VALVE F CSA Certified and ASME Rated T&P Relief Valve • Meets UBC, CEC and ICC National Codes. C SIDE INLET Green Choice® Gas Burner Code Compliance J Model Number GPHE-50 Recovery @ BTU First Hour Gallon 90°F Rise Gallon Input Delivery Capacity Per Hour Per Hour Gallons 50 92 76,000 Approx. Shipping Weight (lbs) 127 210 Dimensions in Inches Model Number A B C D E F G H J K GPHE-50 71 68-5/8 52 21 9-1/8 12 22 8 15-3/4 27 Available in natural gas only. Standard model certified for sea level to 5,300 ft. elevation. Order SMR K30 for elevations to 10,100 ft. Optional Condensate Neutralizer Kit available (Part Number 9007959005). 5 RESIDENTIAL GAS VERTEX™ HIGH EFFICIENCY POWER DIRECT VENT ROUGH IN DIMENSIONS: 50 GALLON UNIT Helical Internal Heat Exchanger • Spiral heat exchanger keeps hot combustion gases in the tank longer to lengthen the heat transfer cycle. T&P • Operates at 96% thermal efficiency, which saves money on operating costs compared to a standard 80% efficient gas water heater. ANODE UPPER SIDE CONNECT Power Direct Vent Design • Combined vertical and horizontal runs terminating through an outside wall. Vents using PVC, CPVC or ABS pipe. OUTLET C DIAMETER • 2”pipe, vents up to 45 equivalent feet. • 3”pipe, vents up to 128 equivalent feet. LOWER SIDE CONNECT • 96% efficient condensing design. E • Equipped with condensate drain tee. • Allows Vertex to be installed as part of combination space heating/water heating applications. INLET B TOP VIEW Condensing Design Side-Mounted Hot and Cold Recirculating Taps F A *INSTALL IN ACCORDANCE WITH LOCAL CODES. D DRAIN FRONT VIEW Figure 1: DIMENSIONS FOR 50 GALLON UNIT ROUGH IN DIMENSIONS: 75 GALLON UNIT Advanced Electronic Control • Large LCD display. • Precise temperature control. F • iCOMM™ compatible and can be monitored from remote locations. INLET UPPER SIDE CONNECT GDHE-75 • Call 1.888.WATER02 for more information. Code Compliance A C • Complies with SCAQMD Rule 1146.2 and other air quality management districts with similar requirements for Ultra-Low NOx emissions requirements of 14 ng/J or 20 PPM. • Meets the thermal efficiency and standby loss requirements of the U. S. Department of Energy and current edition of ASHRAE/IENSA 90.1. Design-Listed by CSA International • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tank-type water heaters. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. DIAMETER E DRAIN ANODE OUTLET I B D Figure 2: DIMENSIONS FOR 75 GALLON UNIT Model Number GDHE-50 GDHE-75 Model Number GDHE-50 GDHE-75 6 LOWER SIDE CONNECT • Meets UBC, CEC and ICC National Codes. GAS PIPING CONNECTIONS T&P • Advanced diagnostics. Recovery @ Gallon BTU Input 90°F Rise Gallon Capacity Per Hour Per Hour 50 75 129 129 100,000 100,000 Vent Size Approx. Shipping Weight (lbs) 2 or 3 2 or 3 255 382 Dimensions in Inches A B C D E F 66-3/4 65-1/4 49-1/4 45-5/8 22 27-3/4 15-3/4 16 3 3-3/4 8 8 Available in Propane (LP) gas. Specify when ordering propane (LP) gas. Models certified for sea level to 10,100 ft. elevation. Optional Condensate Neutralizer Kit available (part number 9007959005). 7 RESIDENTIAL GAS NON-CONDENSING POWER VENT ANODE D COLD HOT Versatile Power Vent Design • All models feature an exclusive 3-position rotatable blower outlet which adds flexibility. • Combined horizontal and vertical vent runs up to 180 equivalent feet with 4” diameter venting (ABS, PVC, CPVC and polypropylene). • All models are equipped with a protected sensor that detects the presence of flammable vapors and automatically disables the burner to prevent ignition. • Air intake snorkel elevates the inlet location of combustion air to prevent flammable vapors from entering the sealed combustion chamber. Hot Surface Ignitor Ø • More robust and reliable than standing pilot, and reduces energy consumption Built-in Heat Traps on the Water Inlet and Outlet Reduce the Amount of Heat Lost Through Piping 2-inch, Thick, “Environmentally-Friendly” Foam Insulation Reduces the Amount of Heat Loss and Contributes to Overall Energy Efficiency User-Friendly • State-of-the-art electronic gas control provides more precise temperature control. • LED control light displays operation status and diagnostics information. Enhanced-Flow Brass Drain Valve Available in Natural Gas and Propane Code Compliance • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA) as amended. Design-Listed by CSA International • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tank-type water heaters. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. 8 Model Number GPVL-40 GPVT-40 GPVL-50 GPVT-50 GPVX-50L †GPVX-75L Model Number Series 200 200 200 200 200 210 40 40 50 50 50 75 0.70 0.70 0.70 0.70 0.70 N/A 44.7 55.9 44.7 55.9 69.3 80.4 40,000 50,000 40,000 50,000 62,000 76,000 73 90 90 96 110 N/A 174 176 198 192 212 277 Dimensions in Inches A 59 GPVT-40 68-1/2 GPVL-50 60-1/8 GPVT-50 68-1/8 GPVX-50L 61-1/8 †GPVX-75L 70-5/8 GPVL-40 Recovery @ BTU Approx. Energy First Gallon 90°F Rise Input Shipping Factor Hour Capacity Gallon Per Gallon Weight (EF) Rating Hour Per Hour (lbs) B C D E F G H 49-5/8 59-1/4 50-3/4 58-3/4 52 61-1/4 22 20 24 22 24 26 29-1/8 27-1/8 31-1/8 29-1/8 31-1/8 33-1/8 11 11 11 11 11 11 13-1/4 13-1/4 13-1/4 13-1/4 13-1/4 13-1/4 42-1/2 53-1/8 43-3/4 51-3/4 44-1/2 53 15-1/4 15-1/4 15-1/4 15-1/4 15-1/4 15-1/4 Available in propane (LP) gas. Specify when ordering propane (LP) gas. Side connections are standard on GPVX models. Side connections available on GPVT models. Add “L” to the model number (example: GPVT-40L). All models are certified from sea level to 10,100 ft. elevation. † GPVX-75L is not ENERGY STAR® Qualified. 9 RESIDENTIAL GAS NON-CONDENSING POWER DIRECT VENT D Power Direct Vent Design • Combined horizontal and vertical vent runs up to 180 equivalent feet with 4” diameter venting (ABS, PVC, CPVC and polypropylene). • Two-pipe sealed combustion system uses outside air, eliminating problems caused by insufficient indoor ventilation. Green Choice® Gas Burner • Patented eco-friendly burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J. Hot Surface Ignitor • More robust and reliable than standing pilot, and reduces energy consumption. C Dynaclean™ Diffuser Dip Tube A B User-Friendly G • State-of-the-art electronic gas control provides more precise temperature control. • LED control light displays operation status and diagnostics information. Enhanced-Flow Brass Drain Valve F H E CSA Certified and ASME Rated T&P Relief Valve Code Compliance • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA) as amended. Design-Listed by CSA International • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tank-type water heaters. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. 10 Model Number Series 200 200 GPDX 50L 200 † GPDX 75L 210 GPDL 40 GPDT 50 Model Number Input BTU/h 40 50 50 75 40,000 45,000 62,000** 76,000 0.71 0.70 0.71 N/A 71 93 115 N/A 45.2 50.3 72.6 82.4 174 192 200 277 Dimensions in Inches A 58-1/4 GPDT 50 67-1/2 GPDX 50L 69 † GPDX 75L 70-5/8 GPDL 40 First Recovery @ Approx. Energy Hour 90°F Rise Shipping Factor Rating Gallon Per Weight Gallon Hour (lb) Gallon Capacity B C D E 49-5/8 58-3/4 60-1/4 61-1/2 22 22 22 26 29-7/8 29-7/8 29-7/8 33-7/8 11 11 11 11 F G H 13-1/4 42-1/2 15-1/4 13-1/4 51-3/4 15-1/4 13-1/4 52-3/4 15-1/4 13-1/4 53 15-1/4 **Propane model has input of 58,000 BTU/hr. Available in propane (LP) gas. Specify when ordering propane (LP) gas. Side connections are standard on GPDX-50L and GPDX-75L. Side connections available on GPDL-40 and GPDT-50. Add “L” to the model number (example: GDPT-50L). All models are certified from sea level to 10,100 ft. elevation. † GPVX-75 is not ENERGY STAR® Qualified. 11 RESIDENTIAL GAS PROMAX® DIRECT VENT Direct Vent Design • One-pipe, dual-channel closed system draws all make-up air from outside the home, eliminating problems caused by insufficient indoor ventilation and is FVIR compliant. • Horizontal air intake and venting on all models up to 80 inches from outside wall with no electrical power needed. MINIMUM VENT 17” MAXIMUM VENT 80” 21º 6” DIA. ON 40 & 50 GAL. MODELS Intelligent Control Logic Green Choice® Gas Burner 3/4” MALE NPT OUTLET & INLET • Patented eco-friendly burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J. Dynaclean™ Diffuser Dip Tube EXTERIOR WALL SIDE TAP AND T&P Coregard™ Andode Rod A FRONT Push Button Piezo Ignitor Heat Trap Nipples Code Compliance E • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1 • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended. Design-Certified by CSA International • Certified at 300 PSI test pressure and 150 PSI working pressure. Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tanktype gas water heaters. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. Model Gallon Number Capacity GDV-40 GDV-50 GDVT-50 Model Number GDV-40 GDV-50 GDVT-50 First Hour Rating Gallon 40 50 50 Recovery Input Energy 9OºF Rise Vent BTU Per Factor Gallon Per Outlet Hour Hour 72 91 92 0.63 0.62 0.61 38,000 40,000 47,000 41 43 51 Co-Axial Co-Axial Co-Axial Approx. Shipping Weight (lbs) 178 200 215 Dimensions in Inches A B C 64 73 74 49-3/4 59 60 22 22 22 D E F 13-1/4 15-1/4 42-1/2 13-1/4 15-1/4 51-3/4 13-1/4 15-1/4 52-3/4 *G H 29 29 29 15-1/4 15-1/4 15-1/4 Dual-channel system has 3” vent pipe inside 6” air intake pipe, for the 40 and 50-gallon models. All models have 2” foam cavity. Water connection is 3/4” male on all models. 40 and 50 gallon models are 8” on center. *Allow 29-1/2” for front to back dimension for gas control and air intake pipe at the rear of the heater. All models are available in propane (LP) gas (series 301). All models are certified from sea level to 7,700 ft. elevation. All models available with side connections. Add “L” to the model number, example GDV-40L. 12 13 A C F B Pressurized Combustion System Installation Friendly ANODE ROD G RESIDENTIAL GAS EFFEX® HIGH EFFICIENCY ATMOSPHERIC VENT GAS VALVE H ON/OFF SWITCH HOT CONNECTION DRAIN VALVE COLD CONNECTION • Allows for easy replacement of standard atmospheric vent heaters. D E • Easily connects to existing B-vent. TOP VIEW Fan-Assisted, Category 1 Appliance • Plugs into standard 110/120V outlet (10 foot power FRONT VIEW cord included). 1/2” 24V Electronic Controls DRAFT HOOD Electronic Ignition T&P VALVE LCD User Interface • Easy-to-read, eye level display. • Simple temperature settings and adjustments. C • Service diagnostics are in plain text. Powered Anode Rod Enhanced-Flow Brass Drain Valve A F B GAS VALVE Dynaclean™ Diffuser Dip Tube H ON/OFF SWITCH DRAIN VALVE Green Choice® Gas Burner • Patented eco-friendly gas burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less then 40 ng/J. CON D Code Compliance • Meets UBC, CEC and HUD National Codes. FRONT VIEW • Meets the thermal efficiency and standby loss requirements of the U. S. Department of Energy and current edition of ASHRAE/IENSA90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act, (EPCA), as amended. Model Number Gallon Capacity First Hour Rating Gallons Energy Factor (EF) BTU Input Gallon Per Hour GAHH-40 40 50 70 81 0.70 0.70 40,000 40,000 Design-Certified by CSA International • Certified at 300 PSI test pressure and 150 PSI working pressure. Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tanktype gas water heaters. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. GAHH-50 Model Number GAHH-40 GAHH-50 14 Recovery Approx. @ 90°F Shipping Rise Weight Gallon Per (lbs) Hour 43 43 157 171 Dimensions in Inches Foam Thickness 2 2 A B C D E F G H Draft Hood 61-3/4 58 20 13-1/4 8 51-1/2 23-1/4 25 3 or 4 60-5/8 57-1/8 22 13-1/4 8 50-1/2 25-1/4 27 3 or 4 Available in natural gas only. Water connection is ¾” on all models. All models are certified from sea level to 10,100 ft. elevation. Requires 120 VAC power supply. 15 RESIDENTIAL GAS HIGH EFFICIENCY NON-CONDENSING FLUE DAMPER ANODE ROD* HOT CONNECTION Automatic Flue Damper COLD CONNECTION • Increases efficiency as it automatically opens and closes to reduce heat loss in the standby mode. E C Electronic Gas Control Diagnostics Electronic Ignition Dynaclean™ Diffuser Dip Tube Green Choice® Gas Burner T&P VALVE • Patented eco-friendly burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J. 1/2" GAS CONNECTION F Coregard™ Anode Rod A B Enhanced-Flow Brass Drain Valve Blue Diamond® Glass Coating D CSA Certified And ASME RATED T&P Relief Valve * Location for optional top-mounted T&P Valve if ordered from factory. Maximum Hydrostatic Working Pressure: 150 PSI. Code Compliance • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IENSA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act, (EPCA), as amended. Design-Certified by CSA International • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to ANSI Z21.10.1 - CSA 4.1 standards governing storage tank-type water heaters. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. Model Number First Recovery @ Energy Gallon Hour 90°F Rise Factor Capacity Rating Gallon Per (EF) Gallons Hour BTU Input Gallon Per Hour Natural* Approx. Shipping Weight (lbs) Tall Models GCF-40 GCF-50 40 50 67 81 0.67 0.67 42 42 40,000 40,000 152 167 40 50 67 88 0.67 0.67 42 42 40,000 40,000 149 175 Short Models GCFL-40 *GCFL-50 Dimensions in Inches Model Number Foam Thickness A B C D E F Draft Hood Outlet 2 2 64-1/4 63-1/2 58-1/4 57-1/4 20 22 13 13 8 8 51-3/4 50-1/4 3 or 4 3 or 4 2 2 54 55-3/4 47-3/4 49-1/2 22 13 8 24 13-1/4 8 41 42-1/2 3 or 4 3 or 4 Tall Models GCF-40 GCF-50 Short Models GCFL-40 *GCFL-50 16 Requires 120 VAC power supply. Water connection is ¾” on all models. Specify when ordering Top T&P. All models are certified from sea level to 10,100 ft. elevation. *GCFL-50 available in natural gas only. All other models available in propane (LP) gas. 17 RESIDENTIAL GAS PROMAX® ATMOSPHERIC VENT Intelligent Control Logic* • *Not available on 60,000 BTU input models (GCRX50 and GCRX-55). Dynaclean™ Diffuser Dip Tube Coregard Anode Rod ™ Push-Button Piezo Ignitor Enhanced-Flow Brass Drain Valve Heat Trap Nipple Blue Diamond® Glass Coating Code Compliance • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended. Design-Certified By CSA International • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tank-type gas water heaters. Model Number First BTU BTU Recovery Approx. Gallon Hour Energy Input Input 90°F Rise Shipping Capacity Rating Factor Natural Propane Gallon Per Weight Gallon Gas Gas Hour (lbs) Tall Models †GCB-30 GCR-30 ‡GCRH-40 †GCB-40 GCR-40* GCG-50* GCR-50* GCRT-50* †GCRX-50* Short Models †GCBL-30 GCRL-30 †GCBL-40 GCRL-40 GCRL-50 30 30 40 40 40 50 50 50 50 64 67 67 70 70 88 88 92 98 0.63 0.63 0.62 0.62 0.62 0.60 0.62 0.60 0.60 35,500 35,500 35,500 40,000 40,000 40,000 40,000 50,000 60,000 32,000 32,000 N/A 36,000 36,000 37,000 37,000 45,000 54,000 37 37 38 42 42 41 43 54 65 123 132 138 130 138 148 165 165 190 30 30 40 40 50 56 62 67 68 93 0.63 0.63 0.62 0.62 0.60 35,500 35,500 40,000 40,000 40,000 32,000 32,000 36,000 36,000 40,000 37 37 41 41 43 110 118 134 135 177 Water connection is ¾” on all models. For 10-year tank and 6-year parts warranty, change “G” to “X” in model number (example: XCR-30). All models approved for installation from sea level to 10,100 ft. elevation. † Models ship with supplied insulation blanket Specify when ordering propane (LP) gas. ‡ LP models not available on GCRH-40 *For optional side-mounted recirculating taps, add "L" to the suffix in the model number. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. Line drawings and dimensions on the following page. 18 19 RESIDENTIAL GAS PROMAX® ATMOSPHERIC VENT (CONTINUED) ANODE ROD (OPTIONAL T&P ANODE ROD LOCATION) (OPTIONAL T&P LOCATION) HOT CONNECTION HOT (ANODE OUTLET CONNECTION ON T&P MODELS) (ANODE OUTLET ON T&P MODELS) E C E C COLD CONNECTION COLD CONNECTION T&P VALVE T&P VALVE 1/2" GAS CONNECTION 1/2" GAS CONNECTION F F H H B B A A D G D G Maximum Hydrostatic Working Pressure: 150 PSI Maximum Hydrostatic Working Pressure: 150 PSI Model Number Tall Models †GCB-30 GCR-30 ‡GCRH-40 †GCB-40 GCR-40* GCG-50* GCR-50* GCRT-50* †GCRX-50* Short Models †GCBL-30 GCRL-30 †GCBL-40 GCRL-40 GCRL-50 Model Number Tall Models †GCB-30 GCR-30 ‡GCRH-40 †GCB-40 GCR-40* GCG-50* GCR-50* GCRT-50* †GCRX-50* Short Models †GCBL-30 GCRL-30 †GCBL-40 GCRL-40 GCRL-50 Dimensions in Inches C A B 61-1/2 61-1/2 61-3/4 61-3/4 61-3/4 60-3/4 60-3/4 60-3/4 65-1/2 58 58 58-1/4 58-1/4 58-1/4 57-1/4 57-1/4 57-1/4 61 50 50 51-1/2 51-1/2 53-1/4 46-1/2 46-1/2 48 48 49-3/4 F D E 16 18 20 18 20 21 22 22 22 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 13-1/2 8 8 8 8 8 8 8 8 8 18 20 20 22 24 12 12 12 12 12 8 8 8 8 8 Dimensions in Inches *G *H Draft Hood 51-3/4 51-3/4 52 52 52 50 1/2 50-1/2 50-1/2 54-1/4 N/A N/A N/A N/A 14-1/4 14-1/4 14-1/4 14-1/4 14-1/4 N/A N/A N/A N/A 51-3/4 50-1/2 50-1/2 50-1/2 50-1/4 3 or 4 3 or 4 3 or 4 3 or 4 3 or 4 3 or 4 3 or 4 4 4 40 40 41-1/4 41-1/4 41-3/8 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 3 or 4 3 or 4 3 or 4 3 or 4 3 or 4 Water connection is ¾” on all models. For 10-year tank and 6-year parts warranty, change “G” to “X” in model number (example: XCR-30). All models approved for installation from sea level to 10,100 ft. elevation. † Models ship with supplied insulation blanket Specify when ordering propane (LP) gas. ‡ LP models not available on GCRH-40 *For optional side-mounted recirculating taps, add "L" to the suffix in the model number. 20 21 RESIDENTIAL GAS HOT WATER INLET PROMAX HIGH RECOVERY ATMOSPHERIC VENT 75 & 100 GALLON ® TOP VIEW COLD WATER INLET E T&P TEMPERATURE AND PRESSURE RELIEF VALVE Highest Recoveries DRAIN • Capacity/input combinations up to 98 VALVE gallons/75,100 BTU’s to produce recoveries up toC81 gallons per hour. COLD HOT Fully Automatic ControlsF with Safety Shutoff B H A HOT WATER INLET • Requires no electrical connections. • Fixed automatic gas shutoff device for added safety. GAS INLET Green Choice® Gas Burner D design reduces NOx • Patented eco-friendly burner emissions up to 33% and complies with Low-NOx emission requirements of 40 ng/J. T&P G DRAIN VALVE Dynaclean™ Diffuser Dip Tube Coregard Anode Rod ™ COLD WATER INLET DRAIN VALVE C FRONT VIEW F Push-Button Piezo Ignitor B H A Blue Diamond® Glass Coating Enhanced-Flow Brass Drain Valve D Code Compliance G • Meets UBC, CEC and ICC National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. FRONT VIEW CSA Certified and ASME Rated T&P Relief Valve Model Number Maximum Hydrostatic Working Pressure 150 psi FCG-100 FCG-75 Gallon Capacity BTU Input Natural Gas Recovery @ 90°F Rise Gallon Per Hour 74 98 75,100 75,100 81 81 Design-Certified By CSA International • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tank-type gas water heaters. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. Model Number FCG-75 FCG-100 Model Number FCG-75 FCG-100 22 Approx. Shipping Weight (lbs) 275 350 Dimensions in Inches A B C D E 61 68-1/2 58-1/2 66-1/2 26-1/2 27-3/4 15-3/16 15-3/16 16 16 Dimensions in Inches F G H Draft Hood 50-1/4 57-3/8 15-1/2 N/A 50-1/4 N/A 4 4 Water connections are 1” male NPT on FCG-75 and 1-1/4” on FCG-100. For 10-year tank and 6-year parts limited warranty, change “F” to “P” in model number (example: PCG-75). For optional side-mounted recirculating taps, add “L” to the suffix of the model number (example: FCG-75L). Specify when ordering propane (LP) gas. All models are certified from sea level to 7,700 ft. elevation. 23 RESIDENTIAL GAS ENERGY SAVER ATMOSPHERIC VENT Complies with HUD Standards for Manufactured Housing Installation ANODE ROD HOT WATER OUTLET CONNECTION 3/4˝ NIPPLE SUPPLIED Gas Control Convertible for Natural and Propane Gas • For flexibility to meet the varying needs of manufactured housing installations. Side-Mounted 3/4” Cold Water Inlets T&P VALVE • For flexibility to meet the varying needs of manufactured housing installations. • Top-mounted 3/4” hot water outlet. Green Choice® Gas Burner • Patented eco-friendly burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J. A Coregard™ Anode Rod B C F COLD WATER INLET CONNECTION, 3/4˝ NIPPLE SUPPLIED Blue Diamond® Glass Coating Enhanced-Flow Brass Drain Valve Code Compliance • Meets UBC, CEC and HUD National Codes. E D • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. GAS CONNECTOR 1/2˝ FEMALE • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended. Design-Certified by CSA International • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tank-type gas water heaters. CSA Certified and ASME Rated T&P Relief Valve Model Number FMHR-30 FMHR-40 Recovery First BTU Input BTU Input Approx. @ 90°F Gallon Hour Energy Per Hour Per Hour Shipping Rise Capacity Rating Factor Natural Propane Weight Gallon Gallon Gas Gas (lbs) Per Hour 30 40 55 62 6-Year Limited Tank and 2-Year Limited Tank Parts Warranty • For complete information, consult written warranty or go to hotwater.com. 0.63 0.62 35,500 35,500 32,000 32,000 36 36 129 153 Dimensions in Inches Model Number FMHR-30 FMHR-40 Insulation 2 2 A B C D E F 61-1/2 58 18 13 14-1/4 52 61-3/4 58-1/4 20 13 14-1/4 51-3/4 Draft Hood Outlet 3 or 4 3 or 4 All models ship from factory for use with natural gas. A complete propane (LP) burner is supplied for converting to propane gas. No option available for top T&P. Certified from sea level to 10,100 ft. elevation. 24 25 RESIDENTIAL GAS ENERGY SAVER DIRECT VENT Complies With HUD Standards For Manufactured Housing Installation ANODE ROD HOT WATER OUTLET CONNECTION 3/4˝ NIPPLE SUPPLIED Gas Control Convertible for Natural and Propane Gas • For flexibility to meet the varying needs of manufactured housing installations. Direct Vent Models Package with Bottom Intake Air Vent T&P VALVE • To draw all combustion make-up air from outside the structure. Optional Ducted Air Inlet Kit for Direct Vent Models • For use when water heater is installed over a basement. A • Provision for horizontal air inlet ducting. Side-Mounted 3/4” Cold Water Inlets B C F COLD WATER INLET CONNECTION, 3/4˝ NIPPLE SUPPLIED Green Choice® Gas Burner • Patented eco-friendly burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J. E Dynaclean™ Diffuser Dip Tube D Coregard™ Anode Rod Enhanced-Flow Brass Drain Valve GAS CONNECTOR 1/2˝ FEMALE Blue Diamond Glass Coating ® Code Compliance • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended. Design-Certified by CSA International • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tank-type gas water heaters. CSA Certified and ASME Rated T&P Relief Valve 6-Year Limited Tank and 2-Year Limited Parts Warranty 26 • For complete information, consult written warranty or go to hotwater.com. Btu Recovery First Btu Approx. Input @ 90°F Model Gallon Hour Energy Input Vent Shipping Per Hour Rise Number Capacity Rating Factor Per Hour Outlet Weight Natural Gallon Gallon Propane (lbs) Gas Per Hour FMDV-30 FMDV-40 FMDV-50 Model Number FMDV-30 FMDV-40 FMDV-50 30 40 50 49 61 77 0.63 30,000 29,000 0.62 32,000 29,000 0.60 40,000 37,000 31 33 39 3 3 3 129 153 168 Dimensions in Inches Insulation 2 2 2 A B 61 58 61-3/4 58-3/4 60 57 C D E F 18 20 22 13 13 13 14-1/4 14-1/4 14-1/4 52-1/2 52-1/4 50 All models ship from the factory for use with natural gas, a complete propane burner is supplied for converting to propane gas. No option available for top T&P. Water connections-3/4” on all models. All models are certified for installation from sea level to 5,400 ft. elevation. 27 RESIDENTIAL GAS PROMAX® ULTRA-LOW NOx ANODE ROD (OPTIONAL T&P LOCATION) HOT CONNECTION (ANODE OUTLETON TOP T&P MODELS) Intelligent Control Logic COLD CONNECTION High Energy Factors E • Eco-Friendly non-CFC foam insulation, external heat traps and specially designed combustion chamber combine to produce a high Energy Factor for maximum savings on operating costs. Green Choice® Gas Burner • Enhanced Ultra-Low NOx burner complies with SCAQMD Rule 1121 and other air quality management districts with similar requirements for NOx emissions of less than 10 ng/J. T&P VALVE C F Dynaclean Diffuser Dip Tube 1/2" GAS CONNECTION Coregard™ Anode Rod Push-Button Piezo Ignitor B H ™ A G D Heat Trap Nipples Maximum Hydrostatic Working Pressure: 150 PSI Blue Diamond® Glass Coating Enhanced-Flow Brass Drain Valve Code Compliance • Meets UBC, CEC and HUD National Codes. Model Gallon Number Capacity Tall Models GUC-30 • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. GUC-40 • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended. GUC-50 CSA Certified by CSA International Design-Certified by CSA International • Certified at 300 PSI test pressure and 150 PSI working pressure. Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tanktype gas water heaters. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. Recovery @ First Hour BTU Input Approx. Energy 90°F Rise Rating Natural Shipping Factor Gallon Per Gallon Gas Weight (lbs) Hour GUR-40 GUR-50 GURT-50L* 30 40 40 50 50 50 55 71 71 91 91 98 0.63 0.62 0.63 0.60 0.62 0.60 33,000 40,000 40,000 40,000 40,000 50,000 34 41 41 42 42 51 126 125 125 148 148 177 40 69 0.62 40,000 41 138 Short Models GURL-40 Dimensions in Inches Model Number A B C 58 D E F G* H* Draft Hood Tall Models GUC-30 61-3/4 16 12 8 51-3/4 N/A N/A 3 or 4 GUC-40 62 58-1/4 18 12 8 52 N/A N/A 3 or 4 GUR-40 62 58-1/4 20 12 8 52 N/A N/A 3 or 4 GUC-50 60-3/4 57-1/4 20 12 8 50-1/2 N/A N/A 3 or 4 GUR-50 60-3/4 57-1/4 22 GURT-50L* 61 57-1/2 22 12 8 50-1/2 N/A N/A 3 or 4 12-1/4 8 50-1/2 12-1/4 50-1/2 4 12 8 41-1/4 N/A N/A 3 or 4 Short Models GURL-40 51-1/2 47-3/4 22 All models may be ordered from the factory with top T&P. Side loop connections are standard on model (GURT-50L). Most models approved for installation from sea level to 7,700 ft. elevation (except on GURT-50L which isapproved to 5,400 ft.). 28 29 RESIDENTIAL GAS BLOWER HIGH EFFICIENCY NONCONDENSING ULTRA-LOW NOx POWER VENT Power Venting Made Simple • Thru-the-wall or thru-the-roof power venting using either 2” or 3” PVC. ABS or CPVC vent pipe. Intelli-Vent™ Gas Control • Advanced electronics for more precise control of water temperature and easy to understand system diagnostics. 40-GAL. = 25" 50-GAL. = 27" EXHAUST OUTLET Combination Thermostat/ECO • Utilizes an intermittent ignition gas valve (no standing pilot) with thermistor temperature sensor and built-in high temperature cut off. E Quiet and Efficient Blower BLOWER • Factory-installed 6-foot power cord with standard 3-prong male connector provided. Electrical requirements; 110/120 VAC power source less than 5 amp draw. Dynaclean™ Diffuser Dip Tube • Reduces lime and sediment buildup and maximizes hot water output. Made from long-lasting PEX crosslinked polymer. Coregard™ Anode Rod Green Choice® Gas Burner • Complies with SCAQMD Rule 1121 and other air quality management districts with similar requirements for NOx emissions of less than 10 ng/J. Enhanced-Flow Brass Drain Valve Code Compliance E • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U. S. Department of Energy and current edition of ASHRAE/IENSA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act, (EPCA), as amended. Design-Certified by CSA-International • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tank-type gas water heaters. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com Model Number Gallon Capacity First Hour Rating Gallon Per Hour GPNH-40 40 50 69 81 GPNH-50 Model Number GPNH-40 GPNH-50 Recovery BTU Approx. @ 90°F Energy Input Shipping Rise Factor Gallon Weight Gallon Per Per Hour (lbs) Hour 0.68 0.68 42.6 42.6 42,000 42,000 Dimensions in Inches 170 207 A B C D E Draft Hood 20 22 66-7/8 66-5/8 58-5/8 57-7/16 51-1/2 51 12-1/4 12-1/4 2 or 3 2 or 3 No option available for top T&P valve. 30 31 RESIDENTIAL GAS PROMAX® ULTRA-LOW NOx DIRECT VENT Flammable Vapor Resistant/Direct Vent Sealed Combustion System Durable, Ultra-Low NOx Burner Construction TOP VIEW 5˝ HOT OUTLET 17˝/22˝ MIN. 80˝ MAX. HORIZONTAL VENT E COLD INLET Non-CFC Foam Insulation • The tank is surrounded by a thick coat of non-CFC polyurethane foam to trap heat inside the tank, saving energy. MAX. HEIGHT IS 68˝ ABOVE TOP OF HEATER THRU-THE-WALL INSTALLATION ¾” Top Water Connections and Side Space Heating Connections ½” Gas Connection Coregard™ Anode Rod Blue Diamond® Glass Coating Enhanced-Flow Brass Drain Valve Green Choice® Gas Burner • Complies with SCAQMD Rule 1121 and other air quality management districts with similar requirements for NOx emissions of less than 10 ng/J. OUTLET C T&P VALVE T&P VALVE A B F H GAS VALVE D INLET G SIDE VIEW FRONT VIEW Code Compliance • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended. CSA Certified And ASME Rated T&P Valve. Design-Listed by CSA International • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to ANSI Z21.10-1- CSA 4.1 standards governing storage tank-type gas water heaters. CSA Certified and ASME Rated T&P Relief Valve 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. 32 Gallon Model Number Capacity GDNL-40L-100 GDNT-50L-100 Recovery @ 90°F Energy Rise Factor Gallon Per Hour First Hour Rating Gallon 40 50 59 81 0.62 0.62 39 41 BTU Input Per Hour Approx. Shipping Weight (lbs) 36,000 38,000 179 193 Model Number Concentric Vent Connection A B C D GDNL-40L-100 3 or 5 65-1/4 50-1/2 22 13-1/2 GDNT-50L-100 3 or 5 73-1/2 58-1/2 22 13-1/2 Model Number GDNL-40L-100 GDNT-50L-100 Dimensions in Inches Dimensions in Inches E F G H 30 30 43-7/8 52-1/4 15 15 45 53 No option available for top T&P valve. All models have ¾” top water connections and comes standard with side loop fittings. All models certified from sea level to 7,700 ft. elevation. 33 K HOT WATER RESIDENTIAL GAS OUTLET ® PROMAX ULTRA-LOW NOx HIGH RECOVERY J TOP VIEW K COLD WATER INLET F H TEMPERATURE AND PRESSURE RELIEF VALVE Fully Automatic Controls with Safety DRAIN Shutoff VALVE Heavy Gauge Steel Jacket D Blue Diamond® Glass Coating Foam Insulation C COLD HOT G B A DRAIN VALVE Ultra-Low NOx Emissions • Complies with SCAQMD Rule 1146.2 and other Air Quality Management Districts with similar E requirements of 14 ng/J or 20 ppm. Easy-To-Install K HOT WATER OUTLET L GAS INLET M K COLD WATER INLET F J • Completely factory-assembled. Only gas, water and vent connections need to be made. All connections are located in front and top of heaters for ease-ofinstallation and service. DRAIN VALVE Coregard Anode Rod ™ D • Our anode rods have a stainless steel core that extends the life of the anode rod allowing superior tank protection far longer than standard anode rods. B Maximum Working Pressure A • 150 psi. Maximum Gas Inlet Pressure • 14” W.C. E Code Compliance M • The Ultra-Low NOx atmospheric vent residential gas water heater meets the thermal efficiency and standby loss requirements of the U. S. Department of Energy and Current Edition ASHRAE/IESNA 90.1. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. Model Number Gallon Recovery @ 90°F Capacity Rise Gallon Per Hour BTU Input Per Hour Approx. Shipping Weight 75,100 75,100 285 lbs 350 lbs GCN-100 74 98 Model A B C D E F GCN-100 62-1/16 70-1/2 58 66-1/2 29-1/2 30-15/16 25-1/4 27-3/4 15-7/8 15-3/16 4 4 Model G H J K L M 15-1/4 15-3/4 16 16 2 1-1/4 1 1-1/4 1/2 1/2 12-1/2 11-15/16 † GCN-75 81 82 Dimensions in Inches GCN-75 Dimensions in Inches GCN-75 GCN-100 34 *Recover rating based on 81% thermal efficiency. **Recover rating based on 80% thermal efficiency. †The GCN-75 comes standard with side loop fittings for use with hydronic heating applications. 35 RESIDENTIAL GAS TANKLESS CONDENSING HIGH EFFICIENCY INDOORMODEL MODEL INDOOR Front view Side view 13-7/8" (352mm) 10" (254mm) 6-1/4" (158.5mm) 4" (102mm) 4" (102mm) 10-13/16" (274.6mm) 10-5/16" (262.2mm) 6" (152.1mm) 2-9/16" (64.8mm) 2-3/4" (70.2mm) ENERGY STAR® Qualified 58.4 24" (609.4mm) Ultra-Low NOx Emissions • Complies with SCAQMD 1146.2 NOx emission requirements of 14 ng/J or 20 PPM. 22-7/8 (580mm) Condensing Technology Provides 0.93 Energy Factor (EF) Copper Primary Heat Exchanger • 25x better heat transfer than stainless steel thus stabilizing outgoing water temperature quicker and reducing pressure drop across the heat exchanger. Hot 4-3/4" (121.1mm) Condensate drain port 5-1/16" (129.1mm) 1" (25.5mm) Condensate drain port 3-1/4" (82.1mm) Gas 4-1/8" (105.4mm) Hot 6-1/2" (164.6mm) Cold 7" (178.5mm) 120VAC 7-3/4" (196.5mm) Cold 1/2" (13.3mm) 120VAC 3-1/16" (77mm) 5-3/8" (137mm) 7-1/16" (180mm) Gas 4/1/2" (113.7mm) Secondary Heat Exchanger MODEL OUTDOOR MODELTop view • Marine-Grade 316L stainless steel to protect against corrosion. Bo om OUTDOOR view 13-5/16" (338.1mm) 22-7/8 (580mm) Factory-Installed Power Cord Included for Indoor Models 6" (152.1mm) COLD 7-1/16" (179.2mm) 1/2" (13.3mm) 4-3/4" (121.1mm) 3-1/16" (77mm) 5-1/16" (129.1mm) 3"4-1/2" (113.7mm) (75.5mm) 8" (203mm) Side view 120VAC 7-3/4" (197.2mm) • Include a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting. 13-7/8" (352mm) 10" (254mm) 7-1/16" (180mm) 5-3/8" (137mm) 2-9/16" (65.8mm) 1-11/16" (42.5mm) GAS 4-3/16" (106.1mm) Outdoor Models Condensate drain port HOT 6-1/2" (165.3mm) • Include a built-in temperature controller and advanced diagnostics to simplify troubleshooting. Front view 3-1/4" (82.8mm) Indoor Models 10-3/4" (272.4mm) 10-5/16" (262.2mm) 2-5/16" (58.4mm) 6-1/4" (158.5mm) Electronic Ignition - No Pilot Light Safety Features: • Air-Fuel Ratio (AFR) Sensor. Condensate drain port 5-1/16" (129.1mm) CSA 4.3 • 15-year limited warranty on heat exchanger in residential applications. • 10-year limited warranty on heat exchanger in commercial applications. • 5-year limited warranty on all parts. Model Number* Condensate drain port 3-1/4" (82.8mm) ANSI Z21.10.3 Hot 6-1/2" (164.6mm) Top view Bo om view HOT 6-1/2" (165.3mm) Warranty Gas 4/1/2" (113.7mm) Cold 7" (178.5mm) Internal Freeze Protection System Power Vent or Power Direct Vent Design 1" (25.5mm) Condensate drain port 3-1/4" (82.1mm) 120VAC 3-13/16" (96.1mm) Gas 4-1/8" (105.4mm) Cold 1/2" (13.3mm) 120VAC 1-7/16" (36.8mm) Type 13-5/16" (338.1mm) Maximum Inlet Gas Pressure Energy Hot/Cold Gas Input Minimum Maximum Factor Connections Connection (BTU/H) (EF) in. W.C. in. W.C. Indoor Models ATI-140H-N Natural 120,000 5.0 10.5 1/2" (13.3mm) 4-3/4" (121.1mm) 1-7/16"Sizing (36.8mm)Chart 5-1/16" (129.1mm) 4-1/2" (113.7mm) Model Number* Type Cold Climate** Indoor Models ATI-140H-N Natural 1.5 0.93 3/4” NPT 1/2” NPT Clearance (Inches) (Number of Showers) GAS 4-3/16" (106.1mm) • Overheat Cut-Off Fuse. 5-3/8" (137mm) 7-1/16" (180mm) COLD 7-1/16" (179.2mm) • Exhaust & Water Temperature Safety Control. Hot 4-3/4" (121.1mm) Warm Climate*** Top Bottom 2 12 12 Side Front 2 4 Back 0.5 *For propane models, change “N” to “P” in the model number (example: ATI-140H-P) For outdoor models change “I” to “O” in the model number (example: ATO-140H-N). **Cold climate represents 70°F temperature rise ***Warm climate represents 50°F temperature rise 36 37 INDOOR MODEL INDOOR MODEL 4" (102 mm) Female ENERGY STAR® Qualified 6-1/4" (159mm) 22-1/2" (570 mm) 24-7/8" (631 mm) Ultra-Low NOx Emissions 5-3/4" (147 mm) 23-5/8" (600 mm) Condensing Technology Provides 0.95 Energy Factor 11-1/4" (285 mm) 4" (101 mm) 4" (102 mm) Female 10-3/4" (272mm) • Complies with SCAQMD 1146.2 NOx emission requirements of 14 ng/J or 20 PPM. HOT 4-3/4" (120 mm) Drain port 6-3/4" (170 mm) Heat Exchanger • Include integrated temperature controls and advanced diagnostics to simplify troubleshooting. • Include factory-installed power cords 11" (281 mm)(448 mm) 17-5/8" 22-1/2" (570 mm) 5-3/4" (147 mm) Indoor Models 11-1/4" (285 mm) 4-1/2" (114 mm) GAS 5-1/8" (131 mm) 3-5/8" (92 mm) COLD 6-3/4" (172 mm) 1-1/2" (37 mm) • Secondary heat exchanger is made of marinegrade 316L stainless steel to protect against corrosion. OUTDOOR MODEL OUTDOOR MODEL Condens ate drain port 7-1/2" (189 mm) HOT 4-3/4" (120 mm) GAS 5-7/8" (147 mm) 17-3/4" (450 mm) 120 VAC 3" (77 mm) 7" (180 mm) 24-7/8" (631 mm) HOT 5-1/2" (140 mm) 23-5/8" (600 mm) 120 VAC 6-7/8" (174 mm) • Primary heat exchanger of the ATI/ATO-540 is constructed of a commercial-grade copper that is more resilient to erosion. Copper is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperature quicker and reducing pressure drop across the heat exchanger. 1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (140 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 120 VAC 6-7/8" (174 mm) Condens ate drain port 7-7/8" (199 mm) COLD 5/8" (17 mm) 120 VAC 3" (77 mm) GAS 5-3/4" (147 mm) Condens ate drain port 7-1/2" (189 mm) Condensate drain port 7-7/8" (199 mm) Maximum Flow Rates up to 10.0 GPM COLD 5/8" (17 mm) 6-1/4" (159 mm) Outdoor Models • Include a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting. 10-3/4" (272 mm) HOT 4-3/4" (120 mm) 120 VAC 6-1/4" (159 mm) Drain port 6-3/4" (170 mm) 1/2" (13 mm) 120 VAC 3" (77 mm) GAS (131 mm) HOT (140 mm) Drain port 6" (152 mm) COLD 5/8" (17 mm) GAS 5-3/4" (147 mm) Condens ate drain port 7-1/2" (189 mm) Common Vent Indoor Models up to 8 Units COLD 6-3/4" (172 mm) Condens ate drain port 7-7/8" (199 mm) 540H ANSI Z21.10.3 CSA 4.3 • Exhaust & Water Temperature Safety Control. • Overheat Cut-off Fuse. Internal Freeze Protection System Power Vent or Power Direct Vent Design Warranty • 15-year limited warranty on heat exchanger in residential applications. • 10-year limited warranty on heat exchanger in commercial applications. 38 • 5-year limited warranty on all parts. Natural 160,000 Natural 180,000 ATI-540H-N Natural 199,000 120 VAC 6-1/4" (159 mm) Model Number* COLD 6-3/4" (172 mm) ATI-240H-N ATI-340H-N 5.0 5.0 5.0 Condensate drain port 7-7/8" (199 mm) • Air-Fuel Ration (AFR) Sensor. 17-5/8" (448 mm) GAS 5-1/8" (131 mm) • Multi-link up to 20 heaters. Safety Features Inlet Gas Pressure Energy Maximum Hot/Cold Gas Condens ate drain port 7-1/2" (189 mm)Minimum Maximum Factor BTU/H Connections Connection (EF) in. W.C. in. W.C. Indoor Models HOT 5-1/2" (140 mm) • Easy-link up to 4 heaters. Model HOT 4-3/4" (120 mm) Type Number* 120 VAC 3" (77 mm) • Can be used in residential and commercial applications Intake 2-5/8" (68 mm) 17-3/4" (450 mm) 7" (180 mm) Exhaust 2-5/8" (65 mm) RESIDENTIAL GAS TANKLESS CONDENSING HIGH EFFICIENCY 10.5 0.95 3/4” NPT 3/4” NPT 10.5 0.95 3/4” NPT 3/4” NPT 10.5 0.95 3/4” NPT 3/4” NPT COLD 5/8" (17 mm) Sizing Chart (Number of Type Clearance (Inches) Showers) Cold Climate** Warm Climate*** Top Bottom Side Front Back Indoor Models ATI-240H-N ATI-340H-N ATI-540H-N Natural Natural Natural 2 3 12 12 2 4 2.5 3.5 12 12 2 4 0.5 3 4 12 12 2 4 0.5 *For propane models, change “N” to “P” in the model number (example:ATI-240H-P) For outdoor models change “I” to “O” in the model number (example: ATO-240-N). **Cold climate represents 70°F temperature rise ***Warm climate represents 50°F temperature rise 0.5 39 INDOOR MODEL 13-3/4" (350mm) 10" (254mm) 4" (101 mm) 13-3/4" (350mm) 10" (254mm) 1-3/4" (45mm) 1-3/4" (45mm) 4-3/8" (113mm) 1-3/4" (45mm) 120V 1-3/8" (36mm) HOT 5-1/4" (133mm) GAS 4-7/8" (124mm) 1-5/8" (43mm) 20-1/4" (520mm) 21-3/8" (544mm) 20-1/4" (520mm) 21-3/8" (544mm) • *Easy-Link up to 4 units 19-3/8" (493mm) OUTDOOR MODEL 13-3/4" (350mm) 13-3/4" (350mm) 10" (254mm)10" (254mm) 7-7/8" (203mm) 7-7/8" (203mm) 1-3/4" (45mm) 1-3/4" (45mm) 1-3/4" (45mm) 1-3/4" (45mm) 5" (128mm) 5" (128mm) Low NOx Emissions ATI-510 & ATO-510 Can Be Used In Both Residential and Commercial Applications 1" (26mm) COLD 2-7/8" (71mm) 1" (26mm) 120VAC 3-7/8" (99mm) COLD 2-7/8" (71mm) GAS 5-1/4" (135mm) 120VAC 3-7/8" (99mm) HOT 6-1/2" (164mm) GAS 5-1/4" (135mm) 9-1/2" (241mm) HOT 6-1/2" (164mm) 9-1/2" (241mm) 4-3/8" (113mm) 4-3/8" (113mm) 19-3/8" (493mm) Factory-Installed Power Cord Included For Indoor Models HOT 5-1/4" (133mm) 1-7/8" (47mm) 120V 1-3/8" (36mm) COLD 3-1/4" (84mm) GAS 4-7/8" (124mm) 19-3/8" (493mm) • Includes a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting 19-3/8" (493mm) 1-7/8" (47mm) COLD 3-1/4" (84mm) Indoor/Outdoor Models 20-1/4" (520mm) 21-3/8" (544mm) 20-1/4" (520mm) 1-3/8" (36mm) 21-3/8" (544mm) • Primary heat exchanger of the ATI/ATO-510 is constructed of a commercial-grade copper that is more resilient to erosion. Copper is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperatures quicker and reducing pressure drop across the heat exchanger 1-5/8" (43mm) 1-3/8" (36mm) Maximum Flow Rates up to 10.0 GPM Copper Primary Heat Exchanger 4-3/8" (113mm) 4" (101 mm) 1-3/4" (45mm) 1-5/8" (43mm) RESIDENTIAL GAS TANKLESS NON-CONDENSING Safety Features • Air-Fuel Ratio (AFR) Sensor 1" (26mm) 1" (26mm) 2-7/8" (71mm) COLD 2-7/8"COLD (71mm) 120VAC 3-7/8" (99mm) 120VAC 3-7/8" (99mm) GAS 5-1/4" (135mm) GAS 5-1/4" (135mm) 120V 1-3/8" (36mm) 120V 1-3/8" (36mm) HOT 6-1/2" (164mm) HOT 6-1/2" (164mm) GAS 4-7/8" (124mm) 9-1/2" (241mm) GAS 4-7/8" (124mm) 9-1/2" (241mm) • Exhaust & Water Temperature Safety Control • Overheat cut-off fuse 1-7/8" (47mm) 1-7/8" (47mm) 3-1/4" (84mm) COLD 3-1/4"COLD (84mm) HOT 5-1/4" (133mm) HOT 5-1/4" (133mm) Internal Freeze Protection Power Vent or Power Direct Vent Design Warranty 510 Models ANSI Z21.10.3 CSA 4.3 • 15-year limited warranty on heat exchanger in residential applications. • 10-year limited warranty on heat exchanger in commercial applications. Model Number* Type Inlet Gas Pressure Maximum Minimum Maximum BTU/H in. W.C. in.W.C. Energy Hot/Cold Gas Factor Connections Connection (EF) Indoor Models ATI-110-N Natural 140,000 5.0 10.5 0.82 3/4” NPT 3/4” NPT ATI-310-N Natural 190,000 5.0 10.5 0.82 3/4” NPT 3/4” NPT ATI-510-N Natural 199,000 5.0 10.5 0.82 3/4” NPT 3/4” NPT • 5-year warranty on all parts. Model Number* Type Sizing Chart (Number of Showers) Clearance (Inches) Cold Warm Top Bottom Side Front Back Climate** Climate*** Indoor Models ATI-110-N Natural 1.5 2 12 12 2 4 0.5 ATI-310-N Natural 2 3 12 12 2 4 0.5 ATI-510-N Natural 2.5 3.5 12 12 2 4 0.5 *For propane models, change “N” to “P” in the model number (example:ATI-110-P) For outdoor models change “I” to “O” in the model number (example: ATO-110-N). **Cold climate represents 70°F temperature rise ***Warm climate represents 50°F temperature rise 40 41 INDOOR MODEL ∅4 (101 mm) Ultra-Low NOx Emissions Maximum Flow Rates Up To 10.0 GPM 1-3/8" (36 mm) 20-1/4" (520mm) • Complies with SCAQMD 1146.2 NOx emission requirements of 14 ng/J or 20 PPM. 4-3/8" (113 mm) 19-3/8" (493 mm) 3-5/8" (94 mm) 13-3/4" (350 mm) 10" (254 mm) 7" (180 mm) 2-1/4" (58 mm) RESIDENTIAL GAS TANKLESS NON-CONDENSING ULTRA-LOW NOx Copper Primary Heat Exchanger 1-7/8" (47 mm) HOT 4-5/8" (116 mm) OUTDOOR MODEL 13-3/4" (350 mm) 5" (128 mm) 120 VAC 1-1/2" (37 mm) • Easy-Link Up To 4 Units. • Multi-Link Up to 20 Units. Safety Features 13-1/8" (334 mm) 5-1/8" (130 mm) 19-3/8" (493 mm) ATI-510U / ATO-510U Can be Used in Both Residential and Commercial Applications COLD 4-7/8"3-5/8" (124 (94 mm) mm) GAS7"1-1/2" (38 mm) (203 mm) 4-3/8" (113 mm) • Include a Wall Mount Temperature Remote Controller and Advanced Diagnostics to Simplify Troubleshooting. 10" (254 mm) 7" (180 mm) 20-1/4" (520 mm)HOT 5" (127 mm) HOT 4-5/8" (119 mm) Indoor/Outdoor Models 1" (26 mm) 120 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 9-1/2" (241 mm) 120 VAC 1-5/8" (40 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm) 120 VAC 1-7/8" (49 mm) 1-5/8" (43 mm) GAS 4-1/4" (109 mm) COLD 5" (127 mm) • Primary heat exchange of the ATI/ATO-510U is constructed of a commercial-grade copper that is more resilient to erosion. Copper is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperatures quicker and reducing pressure drop across the heat exchanger indoor and outdoor models available. 1" (26 mm) 120 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 9-1/2" (241 mm) 120 VAC 1-5/8" (40 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm) 1-7/8" (47 mm) HOT 4-5/8" (116 mm) • Air-fuel ratio (AFR) Sensor. • Exhaust & Water Temperature Safety Control. Internal Freeze Protection 13-1/8" (334 mm) Inlet Gas Pressure Type Energy Maximum Hot/Cold Gas Minimum Maximum Factor BTU/H Connections Connection (EF) in.W.C. in. W.C. Power Vent or Power Direct Vent Design Indoor Models Warranty 5.0 10.5 0.82 3/4” NPT 3/4” NPT ATI-310U-N Natural 190,000 5.0 10.5 0.82 3/4” NPT 3/4” NPT ATI-510U-N Natural 199,000 5.0 10.5 0.82 3/4” NPT 3/4” NPT • 15-year limited warranty on heat exchanger in residential applications. • 5-year limited warranty on heat exchanger in commercial applications. • 5-year limited warranty on all parts. ANSI Z21.10.3 Model Number* COLD 4-7/8" (124 mm) GAS 1-1/2" (38 mm) ATI-110U-N Natural 140,000 120 VAC 1-7/8" (49 mm) GAS 4-1/4" (109 mm) COLD 5" (127 mm) 510U Models HOT 4-5/8" (119 mm) HOT 5" (127 mm) • Overheat cut-off fuse. 120 VAC 1-1/2" (37 mm) Model Number* Type Sizing Chart (Number of Showers) Clearance (Inches) Cold Climate** Warm Climate*** Top Bottom Side Front Back Indoor Models ATI-110U-N Natural 1.5 2 12 12 2 4 0.5 ATI-310U-N Natural 2 3 12 12 2 4 0.5 ATI-510U-N Natural 2.5 3.5 12 12 2 4 0.5 *Available in Natural Gas only For outdoor models change “I” to “O” in the model number (example: ATO-110U-N) **Cold climate represents 70°F temperature rise ***Warm climate represents 50°F temperature rise 42 43 RESIDENTIAL ELECTRIC VOLTEX® HYBRID ELECTRIC HEAT PUMP Increased Energy Efficiency • Improved efficiency designed in, to ensure available hot water at the lowest possible cost. • Up to a 3.24 Energy Factor (EF) Rating conserves energy and meets ENERGY STAR® qualifications. Dual Voltage Capable • 208/240 VAC 60Hz capable for use in almost any residential installation. Choice of Operating Modes • Select from Efficiency, Hybrid, or Electric modes to match heating requirements to environmental conditions and hot water demand. Hybrid mode automatically adjusts between compressor and element, depending upon heat requirements. • Vacation mode reduces operating costs and provides freeze protection during extended absence. A B C E Backup Electric Elements • Long-lasting 4500W backup heating elements help heat water according to environmental conditions, demand, and the chosen operating mode. Dry Fire Protection • Control system checks to ensure the tank is full of water during start up to prevent dry firing the heating elements. D Electronic User Interface • User-friendly electronic interface allows easy control of temperature setting, operating mode, and communicates diagnostics. • Easy to read temperature display shows temperature in °F or °C. • Advanced diagnostics convey error messages for service purposes. The last four error messages are saved in the control system memory. Other Features • Ideal for basements or garage installations; the compressor transfers heat to the water while dehumidifying and cooling the ambient air. • Washable air filter is easily removed for routine cleaning. 10-Year Limited Warranty • For complete information, consult written warranty or go to hotwater.com. Model Number HPTU-50 HPTU-66 HPTU-80 Model Number HPTU-50 HPTU-66 HPTU-80 Gallon Capacity 50 66 80 1st Hour Rating (Gal) By Mode Energy Factor by Mode Efficiency Hybrid Electric Efficiency Hybrid Electric 3.61 3.44 3.27 3.24 3.17 3.06 0.93 0.92 0.92 44.4 62.5 76.3 70 80 95 Dimensions in Inches 57.3 78.6 90.1 A B C D E Approx. Shipping Weight (lbs) 63 61 69 22 27 27 40-5/8 38 46 3-3/4 4 4 40-1/2 38 46 196 289 307 Requires 30 amp breaker. Top T&P option not available on this model. 44 45 RESIDENTIAL ELECTRIC VOLTEX® LEGACY HYBRID ELECTRIC HEAT PUMP Increased Storage • High capacity storage tank enables the heat pump to operate more frequently than backup heating elements. This improves energy efficiency and lowers operating costs, saving more money than lower capacity unit. • High capacity storage tank provides more hot water for peak demand periods. Energy Efficiency • Up to a 2.33 Energy Factor (EF) Rating conserves energy and meets ENERGY STAR® qualifications. A Choice of Operating Modes • Select from efficiency, hybrid, or electric modes to match heating requirements to environmental conditions and hot water demand. Hybrid mode automatically adjusts between compressor and element, depending upon heat requirements. Vacation mode reduces operating costs and provides freeze protection during extended absence. E C Backup Electric Elements • Long-lasting,240VAC incoloy heating elements, 2000W lower and 4500W upper, help heat water when in conventional Electric or Hybrid modes. D Dry Fire Protection • Control system ensures the tank is full of water during start up, to prevent dry firing the heating elements. Electronic User Interface • User-friendly LCD touch-pad control, with plain English text and intuitive status icons provides easy interaction. • Large LCD temperature display (see back) shows temperature in °F or °C. • 3 line, 13 character back-lit LCD display communicates current set point, status and operational information. Energy Factor by Mode Model Number Gallon Capacity Efficiency* Hybrid Electric Approx. Shipping Weight (lbs) • Advanced diagnostics convey error messages in plain English. The last four error messages are saved in the control system memory. HHPT-80 80 2.30 2.33 0.85 340 • Child resistant safety lock deters unwanted access to temperature and operational settings. Model Number Accessory Inlet/Outlet Duct Kits with Booster Fan (Part Numbers: 9910005000, 9910006000, & 9910057000) HHPT-80 1st Hour Rating (Gal) By Mode Efficiency Hybrid Electric 70 84 76 Dimensions in Inches A B 82-1/2 24-1/2 C 55 D E 4-1/4 56-1/3 Requires 30 amp breaker. Top T&P option not available on this model. 6-Year Limited Warranty 46 • For complete information, consult written warranty go to hotwater.com 47 RESIDENTIAL ELECTRIC VOLTEX® HYBRID ELECTRIC HEAT PUMP Increased Energy Efficiency • Improved efficiency designed in, to ensure available hot water at the lowest possible cost. • Up to a 2.75 Energy Factor (EF) Rating conserves energy and meets ENERGY STAR® qualifications. Choice of Operating Modes • Select from Efficiency, Hybrid, or Electric modes to match heating requirements to environmental conditions and hot water demand. Hybrid mode automatically adjusts between compressor and element, depending upon heat requirements. • Vacation mode reduces operating costs and provides freeze protection during extended absence. A Backup Electric Elements • Long-lasting 4500W backup heating elements help heat water according to environmental conditions, demand, and the chosen operating mode. B C E Dry Fire Protection • Control system checks to ensure the tank is full of water during start up to prevent dry firing the heating elements. Electronic User Interface • User-friendly electronic interface allows easy control of temperature setting, operating mode, and communicates diagnostics. D • Easy to read temperature display (see back) shows temperature in °F or °C. • Advanced diagnostics convey error messages for service purposes. The last four error messages are saved in the control system memory. Other Features • Ideal for basements or garage installations; the compressor transfers heat to the water while dehumidifying and cooling the ambient air. • Washable air filter is easily removed for routine cleaning. Model Gallon Number Capacity Efficiency Hybrid FHPT-80 2.78 2.71 2.71 Model Number A B C D E Approx. Shipping Weight (lbs.) 63 61 69 22 27 27 40-5/8 38 46 3-3/4 4 4 40-1/2 38 46 196 285 302 FHPT-66 FHPT-50 FHPT-66 FHPT-80 2.75 2.74 2.72 Electric Efficiency Hybrid Electric 50 66 80 FHPT-50 6-Year Limited Warranty • For complete information, consult written warranty or go to hotwater.com. 1st Hour Rating (Gal) by Mode Energy Factor by Mode 0.89 0.91 0.92 42.1 59.7 71 67.5 81 90 Dimensions in Inches 59.1 79 88 Requires 30 amp breaker. Top T&P option not available on this model. 48 49 INTERFACE RESIDENTIAL ELECTRIC CONSERVATIONIST ACCESS SELF-CLEANING ANODE SMART PORT MODULE CONNECTION PANEL Electronic User Interface • Touchscreen display. DRAIN VALVE T&P VALVE • Multiple operating modes help save money. • Energy Saver and vacation modes available. • Diagnostic feedback. JUNCTION BOX • Dry fire protection. • Grid management ready. T&P VALVE • CEA-2045 Bridge module compatible. Enhanced Heating Elements ACCESS PANEL & USER INTERFACE • Dual 5500 watt elements for the fastest recovery and reliable operation. • Incoloy stainless steel elements last longer than standard copper elements. ENERGY SMART S TANDARD VAC ATION GRID ENABLED F °F/°C Enhanced-Flow Brass Drain Valve Code Compliance ACCESS PANEL • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. DRAIN VALVE • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended. Approved for Manufactured Housing • All residential electric water heaters are compliant with HUD standards for mobile homes/manufactured housing. Design-Listed by Underwriters Laboratories Model Number Gallon Capacity First Hour Rating Gallon Energy Factor Recovery @ 90˚F Rise Gallon Per Hour Approx. Shipping Weight (lbs) 40 50 55 61 79 79 0.95 0.95 0.94 25 25 25 118 134 145 40 50 56 58 0.95 0.95 25 25 109 161 Tall Models PXNT-40 PXNT-50 • Certified at 300 PSI test pressure and 150 PSI working pressure. PXNT-55 • Listed according to UL 174 standards governing storage tank-type electric water heaters. PXNS-40 Short Models PXNS-50 10-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. Model Number Element Wattage 240V Dimensions in Inches Standard Maximum A B C 5500 5500 5500 6000 6000 6000 60-1/4 60-1/2 56-1/2 53-1/4 51-1/4 48-1/2 20 22 24 5500 5500 6000 6000 50 49-3/4 40-3/4 40-1/4 22 24 Tall Models PXNT-40 PXNT-50 PXNT-55 Short Models PXNS-40 PXNS-50 50 Only available for 240V or 208V applications. Equipped as dual element only; no single element configurations available. Top T&P option not available on these models. ¾” water connections on 8” center. 51 RESIDENTIAL ELECTRIC PROMAX® STANDARD Model Number Enhanced Heating Elements • Dual 4500 watt elements for the fastest recovery and reliable operation. • Incoloy stainless steel lower element lasts longer than standard copper elements. High Energy Factors Dynaclean™ Diffuser Dip Tube Recovery @ 90°F Approx. Gallon First Hour Energy Rise Gallon Per Shipping Capacity Rating Gallon Factor Hour Weight (lbs) Tall Models ENT-30† ENT-40† ENTB-50* ENT-50† ENT-55† 30 40 50 50 55 47 51 70 71 76 0.95 0.95 0.95 0.95 0.94 21 21 21 21 21 95 118 131 134 145 30 30 40 50 48 49 55 62 0.95 0.95 0.95 0.95 21 21 21 21 95 94 109 161 N/A 0.95 0.95 0.95 0.95 21 21 21 21 21 65 96 115 118 118 Short Models ENSB-30* ENS-30† ENS-40† ENS-50† Coregard Anode Rod ™ Code Compliance • Meets UBC, CEC and HUD National Codes. Lowboy Top Connect Models • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. ENL-20 ENLB-30* ENL-30† ENLB-40* ENL-40†+ • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended. Approved for Manufactured Housing • All residential electric water heaters are compliant with HUD standards for mobile homes/manufactured housing. Model Number • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to UL 174 standards governing storage tank-type electric water heaters. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. N/A 40 43 46 44 Element Wattage 240V Dimensions in Inches Standard Maximum A B C 4500 4500 4500 4500 4500 6000 6000 6000 6000 6000 46-1/2 60-1/4 60-1/4 60-1/2 56-1/2 39-1/2 53-1/4 51-1/4 51-1/4 48-1/2 19 20 21 22 24 4500 4500 4500 4500 6000 6000 6000 6000 39 39-3/4 50 49-3/4 30-1/2 30-1/2 40-3/4 40-3/8 20 22 22 24 N/A 6000 6000 6000 6000 30 30 31-1/4 31-3/4 33-1/2 21-1/4 21-3/4 21-3/4 24 24 20 22 24 24 26 Tall Models ENT-30† ENT-40† Design-Listed by Underwriters Laboratories 19.5 28 28 38 38 ENTB-50* ENT-50† ENT-55† Short Models ENSB-30* ENS-30† ENS-40† ENS-50† Lowboy Top Connect Models ENL-20 ENLB-30* ENL-30† ENLB-40* ENL-40†+ T&P VALVE T&PVALVE ACCESS ACCESS PANEL PANEL ANODE ANODE JUNCTION JUNCTION BOX BOX ACCESS ACCESS PANEL PANEL DRAIN DRAIN VALVE VALVE 52 4500 4500 4500 4500 4500 * Models ship with supplied insulation blanket. † For 10-year tank and 6-year parts warranty, change "E" to "P" in the model number (example: ENT-30 becomes PNT). + Top T&P option not available on this model. ¾” water connections on 8” center. ENL-20 is a single element configuration only T&P T&PVALVE VALVE 53 RESIDENTIAL ELECTRIC PROMAX® MOBILE HOME Approved for Manufactured Housing • All residential electric water heaters are compliant with HUD standards for mobile homes/manufactured housing. ANODE C JUNCTION BOX Side Water Connections T&P VALVE • For ease of installation in mobile home applications. Coregard Anode Rod ™ WATER CONNECTIONS • Our anode rods have a stainless steel core that extends the life of the anode rod allowing superior tank protection far longer than standard anode rods. Long-Lasting Heating Elements T&P VALVE • Screw-in, direct immersion, 3500W/240V or 3000W/120V heating elements for maximum efficiency. OUTLET Blue Diamond® Glass Coating Enhanced-Flow Brass Drain Valve • Our residential water heaters have a solid brass, tamper resistant, enhanced-flow, ball type, drain valve. C E • Uses a standard female hose fitting that allows for fast and easy draining during maintenance. CSA Certified and ASME Rated T&P Relief Valve INLET • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended. Design-Listed by Underwriters Laboratories • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to UL 174 standards governing storage tank-type electric water heaters. 6-Year Limited Tank and Parts Warranty • For complete information, consult written warranty or go to hotwater.com. Model Number MHE6-30H-030D MHE6-30H-035D MHE6-40R-030D MHE6-40R-035D MHE6-30L-030D* MHE6-30L-035D* MHE6-30H-030D MHE6-30H-035D MHE6-40R-030D MHE6-40R-035D MHE6-30L-030D* MHE6-30L-035D* 54 First Gallon Hour Capacity Rating Gallon 30 30 40 40 28 28 42 42 51 51 40 40 Recovery Approx. Energy @ 90˚F Rise Shipping Voltage Factor Gallon Per Weight Hour (lbs) 0.95 0.95 0.95 0.95 0.95 0.95 Wattage Model Number A DRAIN VALVE D Code Compliance B Upper Lower Element Element 3000 3500 3000 3500 3000 3500 14 16 14 16 14 16 120 240 120 240 120 240 98 98 109 109 96 96 Dimensions in Inches A B 3000 46-3/4 39-1/2 3500 46-3/4 39-1/2 3000 50 40-3/4 3500 50 40-3/4 3000 30 21-3/4 3500 30 21-3/4 C D E 19 19 22 22 22 22 3-7/8 3-7/8 4-3/8 4-3/8 4-1/2 4-1/2 39-5/8 39-5/8 41 41 22 22 * Models ship with supplied insulation blanket. MHE6 models may have limited element options due to element size or other restrictions. Available with side T&P only. ¾” water connections. 55 RESIDENTIAL ELECTRIC PROMAX® SPECIALTY ELECTRIC Approved For Manufactured Housing • All residential electric water heaters are compliant with HUD standards for mobile homes/manufactured housing. Table-Top • Features a convenient flat porcelain surface at 36" height, providing extra "counter space" wherever installed. All plumbing and electrical connections are made through the back of the water heater. This heater is equipped with a PEX cross-linked polymer dip tube. Point-of-Use • Designed for low-demand, such as office lavatories or buildings with remote rest rooms. LOWBOY Compact • Side-mounted plumbing and electrical connections (optional top-mounted water connections for field conversion). Designed for installation under a counter, in a crawl space or in other tight spaces. Code Compliance TABLE TOP EJC-10 EJCS-20 EJCT-20 • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1. • Listed according to UL 174 standards governing storage tank-type electric water heaters. 6-Year Limited Tank And Parts Warranty • For complete information, consult written warranty or go to hotwater.com. Energy Factor Element Wattage Standard ENJB-40* ENJ-40 240V 3000 6000 6000 6000 N/A N/A N/A N/A N/A N/A N/A N/A 1650 1650 2500 2500 28 28 38 38 39 39 47 44 0.95 0.95 0.95 0.95 4500 4500 4500 4500 38 45 0.88 4500 240V Table Top Model ESTT-40 Model Number 6000 6000 6000 6000 240V Point-Of-Use-Models 5500 120V 2.5 EJC-2 Maximum 120V Lowboy Side-Connect Model ENJ-30 • Certified at 300 PSI test pressure and 150 PSI working pressure. First Hour Rating Gallon 6 10 19 19.9 EJC-6 • Meets UBC, CEC and HUD National Codes. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended. Gallon Capacity Compact Models ENJB-30* Design-Listed By Underwriters Laboratories COMPACT Model Number N/A Recovery @ 90˚F Rise Gallons Per Hour N/A 1500 @ 120V Dimensions in Inches A B C Approx. Shipping Weight (lbs) 15-1/4 18-1/4 24-3/4 31-5/8 10-3/4 12-1/4 18-5/8 25-3/4 14-1/4 16 18 16 35 41 68 68 21 21 21 21 30 31-1/4 31-3/4 33-1/2 21-3/4 21-3/4 24 24 22 24 24 26 101 115 118 118 21 36 24 25 150 7 13-3/4 11 13-3/4 20 Compact Models EJC-6 EJC-10 EJCS-20 EJCT-20 8 8 11 11 Lowboy Side-Connect Model ENJB-30* ENJ-30 ENJB-40* ENJ-40 Table Top Model POINT-OF-USE ESTT-40 Point-Of-Use-Models EJC-2 56 *Models ship with supplied insulation blanket. 57 RESIDENTIAL PUMP TANKS Dimensions in Inches Certified to NSF/ANSI 61-G and 372 ultiple Head Construction Adds Structural Strength and More M Capacity within the Same Diameters • Interior powder coating is permanently bonded to the tank shell for ultimate protection on the water side of the tank. • Butyl rubber parabolic diaphragm. • Positive lock retention system controls compression in the diaphragm connection, eliminating air loss or water leaks in tank. • Electrostatically applied powder-coated exterior for maximum sunlight (UV) resistance with zinc phosphate undercoat for highest corrosion resistance. Model Number PMI-2 PMI-5 PMI-7 PMI-14 PM-14 PM-20 PM-26 • PM-32 • 5-year limited warranty. Overall Height -A Weight To Center of Water Diameter-B (lbs.) Inlet PMI (Inline) and PM (Free-Standing) Series • Corrosion-resistant metal air valve. No-weld steel base Volume Connecting (Gallons) NPT Size PM-45 PM-65 PM-85 PM-86 PM-119 2.0 4.6 7.3 13.9 13.9 19.9 25.9 31.8 45.2 65.1 84.9 83.5 115.9 3/4 (M) 3/4 (M) 3/4 (M) 1 (M) 1 (F) 1 (F) 1 (F) 1 (F) 1-1/4 (F) 1-1/4 (F) 1-1/4 (F) 1-1/4 (F) 1-1/4 (F) Horizontal Series PMH-7 PMH-14 PMH-20 7.3 13.9 19.9 10-3/16 14-3/4 21-1/16 21-1/16 24-15/16 32-3/8 39-9/16 47-1/4 36-9/16 48-5/8 60-11/16 46 61-5/16 2 2 2 2 2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 Length-A 3/4 (M) 1 (M) 1 (M) 12-7/8 18-1/4 18-1/4 8-1/4 11 11 15-3/8 15-3/8 15-3/8 15-3/8 15-3/8 22 22 22 26 26 5 9 14 24 24 34 43 52 65 90 114 116 161 Diameter-B - 11 15-3/8 15-3/8 16 25 36 NOTE: M-Male connection F-Female connection All models 38 PSI pre-charge 58 59 RESIDENTIAL EXPANSION TANKS Model Number Maximum (PSIG) Working Pressure Tank Volume (Gallons) Maximum Accepted Volume (Gallons) 20 PSI 40 PSI 60 PSI PMC-Series (Potable Expansion Tanks - 5-Year Limited Warranty) PMC-2 PMC-5 PMC-10 150 150 150 1.96 4.55 9.25 1.53 3.75 7.80 1.27 3.05 6.55 1.03 2.19 5.25 TW-Series (Potable Expansion Tanks - 1-Year Limited Warranty) Certified to NSF/ANSI 61-G and 372 When used in potable applications TW-5 TW-12 2.10 4.40 1.53 3.75 1.27 3.05 1.03 2.19 PMET-Series (Hydronic Expansion Tanks - 1-Year Limited Warranty) PMET-2 Interior Powder Coating is Permanently Bonded to the Tank Shell for Ultimate Protection on the Inside of the Tank 150 150 PMET-5 PMET-7 PMET-14 100 100 100 100 1.96 4.55 7.30 14.6 1.53 3.75 4.60 10.5 N/A N/A N/A N/A N/A N/A N/A N/A Butyl Rubber Parabolic Diaphragm Positive Lock Retention System Controls Compression in the Diaphragm Connection, Eliminating Air Loss or Water Leaks in Tank Model Number PMC-5 PMC-10 5-Year Limited Warranty on PMC Expansion Tanks Diameter - B Weight (lbs) 3/4 3/4 3/4 10-3/16 14-3/4 15-1/2 8-1/4 11 15-3/8 5 9 18 TW-Series (Potable Expansion Tanks - 1-Year Limited Warranty) TW-5 1-Year Limited Warranty on TW Series Expansion Tanks Dimensions in Inches Overall Height - A PMC-Series (Potable Expansion Tanks - 5-Year Limited Warranty) PMC-2 Projection Welded Air Valve Connection NPT Size TW-12 3/4 3/4 10-3/16 14-3/4 8-1/4 11 5 9 PMET-Series (Hydronic Expansion Tanks - 1-Year Limited Warranty) 1-Year Limited Warranty on Hydronic Expansion Tanks PMET-2 PMET-5 PMET-7 PMET-14 60 1/2 1/2 1/2 1/2 10-3/16 14-3/4 21-1/16 23-1/2 All PMC and TW Series models 38 PSI pre-charge. All PMET models 12 PSI pre-charge. 8-1/4 11 11 15-3/8 5 9 14 25 61 COMMERCIAL WATER SYSTEMS iCOMM™ REMOTE MONITORING SYSTEM iCOMM Requirements •Facility must have “always on” internet (wired or wireless) •iCOMM compatible water heaters (see next page for compatible models) What is iCOMM™ Elite? iCOMM™ Elite utilizes the latest technology in commercial water heating to allow us to interact with, pro-actively manage and monitor your A. O. Smith water heaters from anywhere in the world via the Internet. With this newly redesigned industry-exclusive service, A. O. Smith can monitor your water heaters around the clock, alert you instantly in case of a problem, and begin fixing any potential problems immediately. How is that for ultimate peace of mind? (Must be ordered within 90 day or water heater installation.) •*Annual iCOMM subscription Who is iCOMM Elite Designed For? •For information and ordering call 1-888-WATER02 or visit www. aosmithconnect.com Any commercial water heater customers, ranging from small businesses with one water heater to national chain operations with thousands of locations. iCOMM Features Elite Compatible Units Include: •Provides remote monitoring via www.aosmithconnect.com •Cyclone® Mxi (BTH models) •E-mail and text messaging of fault conditions •Custom Xi (DSE models) •Graphs unit performance and operational history •Gold Xi (DVE models) •BACnet compatibility with building management systems Valet Service on Any Warranty Claim! Compatible Products Include: •Cyclone® Xi (Mxi, Xi and BTX(L)100 models) •Custom® Xi (DVE-DHE models) •Gold Xi (DVE models) •Genesis® Domestic Water Heaters and Boilers manufactured between July 2009 and January 2014 (GB/GW models, 100-599 series) •VF™ Variable Fire Domestic Water Heaters and Boilers manufactured between July 2009 and January 2014 (VB/VW models, 100-299 series) Should you experience problems with any products that are still under warranty–it’s time for the VIP treatment. We will do everything to get you back on track, and we mean everything. Our complete valet service includes a call before the service, handling all the logistics, repairing the product, and of course, superior service throughout the process. COMPLETE COVERAGE,TOTAL PEACE OF MIND GET iCOMM™ ELITE IN 3 EASY STEPS: 1.Confirm you have a compatible unit. 2.Verify that you have an internet connection in the same room as the water heater(s). 3.Call 1-888-WATER02 to purchase and arrange installation. HARDWARE Model Number ICMA IDMA 62 IABA ICMA Item Description iCOMM Main communications board Communications required for any iCOMM installation. Module IMDA iCOMM Multi-Device Adapter IABA iCOMM Alarm Box Needed if more than one water heater will be connected to the control module. Order 1 MDA for each water heater installed. Accessory alarm box that includes an audible alarm and alarm light. iCOMM™ Subscription (Required) Per iCOMM Communication Module for Elite services *iCOMM subscription is required to use the “iCOMM Elite service”. End user responsible for paying and maintaining annual subscription. Installation and subscription service fees are net prices paid directly by the end user. No distributor discounts are applicable. For information and ordering call 1.888.WATER02 63 or visit www.aosmithconnect.com COMMERCIAL WATER SYSTEMS BUILDING MANAGEMENT SYSTEM BACnet & MODBUS INTERFACE INTRODUCING THE BMS GATEWAY FOR CONTROL OF A. O. SMITH WATER HEATERS Connect Your A. O. Smith Water Heater to your Building Management System Using the New Millennium Control from ICC* (Industrial Control Communications, Inc.) • Works with Cyclone, McBee DVE, Renton DSE/DVE/ DHE (Except BTX-80) • Use the ICC Control to enable/disable the water heater • Change Temperature Set points and differentials • Two models with four different configurations to connect to BACnet and Modbus • Ethernet and Serial RS-485 versions available • 2 wire or 4 wire RS-485 Network • Power can be supplied via the USB cable, as a 7-24 VDC input on the main terminal Block, or via IEEE 802.3af Power over Ethernet (PoE on ETH-1000 only) • Configure protocols, network characteristics, and client/server object definitions • Graphically interact with the internal database in real-time via USB connection • Automatically discover and configure IP settings Ethernet gateways connected to the current subnet • Update Firmware MODELS: ETH-1000 Ethernet Connection (Shown) XLTR-1000 Serial RS-485 Connection ICC Energy Management Interfaces Protocol Part Number 991009300 BACnet 991009400 Connection Type Serial (RS485) Application Commercial Gas - Cyclone® BTH and BTX (L)-100 Commercial Electric DSE, DVE, DHE Commercial Gas - Cyclone® BTH and BTX (L)-100 Ethernet (IP) Commercial Electric DSE, 9910100000 DVE, DHE Commercial Gas - Cyclone® 9910096000 BTH and BTX (L)-100 Serial (RS485) Commercial Electric DSE, 9910097000 DVE, DHE 991009900 Modbus 991010200 Ethernet (IP) 9910103000 Commercial Gas - Cyclone® BTH and BTX (L)-100 Commercial Electric DSE, DVE, DHE • Heater connection wiring supplied with unit • For questions on this product Call 888-928-3702 Opt 1 • RTU and serial connect via RS-485 • Ethernet and IP connect via RJ-45 64 65 T & P VALVE COMMERCIAL GAS CYCLONE® HE SIDE OUTLET H ANODE Power Vent Design A for Installation Versatility HOT B G DIAMETER • Modular blower, with 120 volt, 60Hz electrical system (5 amps or less), 6-foot cord with standard SIDE INLET 3-prong connector J C TOP VIEW • Combined vertical and horizontal runs terminating THERMOSTAT through an outside wall, using Schedule 40 PVC, DRAIN CPVC or ABS or polypropylene pipe: Canadian VALVE installations require ULC S636 approved pipe for venting • 2” pipe allows ventF runs up to 25 equivalent feet K COLD * INSTALL IN ACCORDANCE WITH LOCAL CODES D OUTLET INLET E • 3” pipe allows vent runs up to 65FRONT VIEW equivalent feet SIDE OUTLET T & P VALVE • 4” pipe allows vent runs up to 128 equivalent feet ANOD High Output with Small Footprint • 22” diameter, combined with 90% efficiency, 50-gallon tank and 76,000 BTU input means Cyclone® HE can be installed in less space than a larger 75-gallon unit, with equal or better performance. A B G DIAMETER Side-Mounted Hot and Cold Recirculating Taps J C SIDE INLET Two Heavy-Duty Anode Rods THERMOSTAT 3-Year Limited Tank and 1-Year Limited Parts Warranty F • For complete warranty information, consult written warranty or go to hotwater.com. * INSTALL IN DRAIN VALVE D E FRONT VIEW Model Number BTX-80 Recovery Capacity GPH @ 100°F Rise BTU Input Per Hour Approx. Shipping Weight (lbs) 50 92 76,000 210 Dimensions in Inches Model Number A B C D E BTX-80 71 68-5/8 52 21 9-1/8 F G H J K 12 22 8 15-3/4 27 Model Number BTX-80 66 Gallon Capacity Dimensions in Inches Available in Natural Gas only. Standard model certified from sea level to 5,300 ft. elevation. Order SMR S54 for elevations to 10,100 ft. Optional Condensate Neutralization Kits available (Part Number 9007959005). 67 COMMERCIAL GAS CYCLONE® Xi Helical Internal Heat Exchanger • Spiral heat exchanger keeps hot combustion gases in the tank longer to lengthen the heat transfer cycle ANODE • Positioned in the center of the tank for more even heat distribution F • Operates at 96% thermal efficiency, which saves money on operating costs compared to a standard 80% efficient gas water heater BTX-100 AN Power Direct Vent Design OUTLET • Combined vertical and horizontal runs terminating through an outside wall. Vents using PVC, CPVC, ABS or polypropylene piping. Canadian installations require ULC S636 approved pipe for venting. INLET TOP VIEW INSTALL IN ACCORDANCE WITH LOCAL CODES. 3” DIAMETER VENT/EXHAUST • 2” pipe, vents up to 45 equivalent feet • 3” pipe, vents up to 128 equivalent feet OUTLET Condensing Design • 96% efficient condensing design 1 3/ 16 ” • Equipped with condensate drain tee 4 1/2” DI AMET ER INSTALL IN AC 1 1/2” 21 1/8” 3-Year Limited Tank and 1-Year Limited Parts Warranty 3” DIAMETER VENT/EXHAUST N AI R 39” 3” DIAMETER PVC INTAKE/COMBUSTIO • For complete warranty information, consult written warranty or go to hotwater.com. OPTIONAL CONCENTRIC VENT KI T 13 1 1/2” 3” DI INTAK FRONT VIEW Model Number BTX-100 Model Number BTX-100 OPTIO Capacity Gallons Recovery Capacity GPH @ 100°F Rise BTU Input Per Hour Approx. Shipping Weight (lbs) 50 129 100,000 255 Dimensions in Inches A B C D E F 66-3/4 49-1/4 22 15-3/4 3 8 Standard model certified from sea level to 10,100 ft. elevation. Optional Concentric Vent Kits (9006328005) and Condensate Neutralization Kits (9007959005). Specify when ordering propane (LP) gas. 68 69 COMMERCIAL GAS CYCLONE® Xi Helical Internal Heat Exchanger • Spiral heat exchanger keeps hot combustion gases in ANODE the tank longer to lengthen the heat transfer cycle • Positioned in the center of the tank for more even heat distribution F BTXL-100 • Operates at 96% thermal efficiency, which saves BTX-100 money on operating costs compared to a standard 80% efficient gas water heater ANODE OUTLET Power Direct Vent Design INLET TOP VIEW F • Combined vertical and horizontal runs terminating ACCORDANCE WITH LOCAL CODES. through an outside wall. Vents usingINSTALL PVC<INCPVC, ABS or polypropylene piping. Canadian installations 3” DIAMETER VENT/EXHAUST require ULC S636 approved pipe for venting. OUTLET • 2” pipe, vents up to 45 equivalent feet INLET TOP VIEW • 3” pipe, vents up to 128 equivalent feet 1 3/ 16 ” Condensing Design 1 1/2” • 96% efficient condensing design 4 1/2” DI AMET ER INSTALL IN ACCORDANCE WITH LOCAL CODES. 21 1/8” 3” DIAMETER PVC INTAKE/COMBUSTIO • Equipped with condensate drain tee 3” DIAMETER VENT/EXHAUST N AI R 39” OPTIONAL CONCENTRIC VENT KI 3-Year Limited Tank and 1-Year Limited Parts Warranty • For complete warranty information, consult written warranty or go to hotwater.com. FRONT VIEW TOP VIEW T 4 1/2” DI AMET ER 1 3/ 16 ” 1 1/2” 21 1/8” 3” DIAMETER PVC INTAKE/COMBUSTIO N AI R 39” OPTIONAL CONCENTRIC VENT KIFRONT T Model Number BTXL-100 Model Number BTXL-100 VIEW Capacity Gallons Recovery Capacity GPH @ 100°F Rise BTU Input Per Hour Approx. Shipping Weight (lbs) 75 129 100,000 382 Dimensions in Inches A B C D E F 65-1/4 45-5/8 27-3/4 16 3-3/4 8 Standard model certified from sea level to 10,100 ft. elevation. Optional Concentric Vent Kits (9006328005) and Condensate Neutralization Kits (9007959005). Specify when ordering propane (LP) gas. 70 71 COMMERCIAL GAS CYCLONE® MXi Up to 98% Efficient Intelligent Control System with LCD Display • Exclusive A. O. Smith designed control system • Provides detailed water heater status information • Precise temperature control adjustable from 90 to 180 degrees • Built-in diagnostics • Run history information • Cyclone water heaters are compatible with the iCOMM™ remote monitoring system. Call 1.888.928.3702 for more information. Submerged Combustion Chamber, with Helical Heat Exchanger Coil Model Number Gallon Capacity Input BTU/HR BTH-120(A) 60 100 100 100 119 119 119 120,000 150,000 199,900 250,000 119,000 119,000 119,000 BTH-150(A) BTH-199(A) BTH-250(A) BTH-300(A) BTH-400(A) BTH-500(A) Approx. Approx. Shipping Weight Shipping Weight (lbs) Std (lbs) ASME 460 523 523 523 855 855 855 490 553 553 553 855 855 855 Optional Concentric Vent Kits 9006328005 (BTH-120 through BTH-250 models). 9008841005 (BTH-300 through BTH-500 models). Electrical characteristics- 120V-60 Hz A.C., 5.0A. “A” in the model number represents ASME construction. Models are certified from sea level to 10,100 ft. elevation. • Positioned in center of tank, surrounded by water to virtually eliminate radiant heat loss from chamber • Direct spark ignition • Spiral heat exchanger keeps hot burner gases swirling, uses centrifugal force to maximize efficiency of heat transfer to water in tank • Spiral heat exchanger reduces lime scale from forming on water-side surfaces, which maintains energy efficiency over time Power Anodes Standard on All Models (For 300, 400 & 500 Models) (For 120-150 Models) • Provides long-lasting tank protection in varying water conditions • Powered anodes are non-sacrificial • Automatically adjusts output needed to properly protect the tank 3-Year Limited Tank and 1-Year Limited Parts Warranty • For complete warranty information, consult written warranty or go to hotwater.com Line drawings and dimensions on the following page. 72 73 FRONT T T& PV AL VE C LE AN US HA EX IN DRA E VALV O U T COMMERCIAL GAS CYCLONE® MXi (CONTINUED) 18° 42° 30° 45° * Center line of water outlet on top of the water heaters is approximately 7 inches from the front edge of the water heater. T&P FRONT ALL MODELS S E 1 1/2” NPT WATER INLET AIR AK INT 26° 3/4” NPT DRAIN C A J G 3/4" NPT RECIRC RETURN 4" EXHAUST VENT CONNECTION C 1 1/2" SUPPLY GAS CONNECTION 1 1/2" NPT WATER OUTLET 4" PVC AIR INTAKE GAS CONNECTION U T WATER OUTLET HEIGHT T O AN T& PV AL VE C LE US HA EX N DRAI E VALV WATER OUTLET HEIGHT 18° 45° BACK T & P VALVE D B LOWER TEMPERATURE PROBE CLEANOUT E 3/4” NPT RECIRCULATION RETURN VENT CONNECTION 3 INCH PVC (exhaust elbow) 1 1/2” NPT WATER INLET 3/4” NPT DRAIN C J G BTH-250(A) A Dimensions in Inches INTAKE AIR CONNECTION 3 INCH PVC B 3 3 3 3 27.75 27.75 27.75 27.75 SUPPLY GAS CONNECTION C D 6.3 6.3 6.3 6.3 35 56.38 BACK 56.38 56.38 I Model Number BTH-120(A) BTH-150(A) BTH-199(A) BTH-250(A) E WATER OUTLET HEIGHT 55.5 76 76 E 76 F H Dimensions in Inches Model Number BTH-300(A) BTH-400(A) BTH-500(A) Model Number F G H I J BTH-300(A) 53.5 75.75 75.75 75.75 11.25 11.25 11.25 11.25 42.25 64 64 64 48.5 70 70 70 18.25 18.25 18.25 18.25 BTH-400(A) Optional Concentric Vent kit 9008841005 (BTH-300 through BTH-500 models). Electrical characteristics- 120V-60 Hz A.C., 5.0A. “A” in the model number represents ASME construction. Models are certified from sea level to 10,100 ft. elevation. 74 I FRONT F A H B E H 42° FRONT 45° * Center line of water outlet on top of the water heaters is approximately 7 inches from the front edge of the water heater. F BTH-199(A) 18° 30° 42° 30° BACK BTH-150(A) TOP T US HA EX FRONT INTAKE AIR CONNECTION 3 INCH PVC BTH-120(A) INT AKE 1½" NPT WATER OUTLET SUPPLY GAS CONNECTION Model Number J G 1 1/2" NPT WATER INLET A I 20° 70° 3/4" NPT DRAIN 90° GA CLEANOUT VENT CONNECTION 3 INCH PVC (exhaust elbow) CLEANOUT D TOP VIEW GAS LOWER TEMPERATURE PROBE E DRA IN B 3/4” NPT RECIRCULATION RETURN CL EA NO UT D FRONT E T& P T & P VALVE BTH-500(A) Dimensions in Inches A B C D E 4.75 4.75 4.75 33.12 33.12 33.12 4.75 4.75 4.75 52 52 52 75.75 75.75 75.75 Dimensions in Inches F G H I J 73.75 73.75 73.75 12.75 12.75 12.75 63.13 63.13 63.13 69.25 69.25 69.25 23 23 23 Optional Concentric Vent kit 9008841005 (BTH-300 through BTH-500 models). Electrical characteristics- 120V-60 Hz A.C., 5.0A. “A” in the model number represents ASME construction. Models are certified from sea level to 10,100 ft. elevation. 75 COMMERCIAL GAS MASTER-FIT® BTR The Eliminator™ Self-Cleaning System • Designed to significantly reduce or eliminate sediment build-up inside the tank • Reduced sediment build-up maintains rated thermal efficiency and reduces water heating costs • Self-cleaning system maximizes tank life Factory-Installed Draft Diverter and Automatic Flue Damper (BTR-120-400 Models) • BTR-500 Model features induced draft design and no damper Model Number BTR-120* BTR-154 BTR-180 BTR-197 BTR-198 BTR-199 BTR-200 (A) BTR-250* (A) BTR-251* (A) BTR-275* (A) • Low-profile draft diverter helps for installation in tight spaces BTR-305 (A) • Automatic motorized flue damper helps minimize standby heat loss BTR-400 (A) Three Water Connection Options for Added Flexibility • Hot and cold water connections can be made through front, top or rear of unit • Eliminator™ system operates when cold water is connected through front BTR-365 (A) BTR-500 (A) Gallon Capacity Input BTU/HR Natural Gas Recovery Capacity GPH @ 100°F Rise 71 81 81 100 100 81 100 100 65 100 65 85 100 85 120,000 154,000 180,000 199,000 199,000 199,000 199,000 250,000 251,000 275,000 305,000 365,000 390,000 500,000 116 149 175 193 193 193 193 242 243 267 296 354 378 485 Specify when ordering propane (LP) gas. *Model BTR 120 is shipped with 6” x 5” flue outlet adapter. Models BTR 250, 251 and 275 are shipped with a 8” x 6” flue outlet adapter. Standard models certified from sea level to 2,000 ft. elevation. Order SMR S54 for elevations up to 8,000 ft. BTR-500 model features induced draft design and no damper. 3-Year Limited Tank and 1-Year Warranty • For complete warranty information, consult written warranty or go to hotwater.com Line drawings and dimensions on the following page. 76 77 COMMERCIAL GAS MASTER-FIT® BTR (CONTINUED) Master-Fit BTR 120-400 INDUCED DRAFT MOTOR I 1˝ NPT RELIEF VALVE OPENING I Model Number Dimensions in Inches A B C D E F 69-3/4 4-1/4 59-1/2 50-7/8 19-11/16 19 73 BTR-180 67-1/2 BTR-197 75 BTR-198 75 BTR-199 67-1/2 BTR-200(A) 72 BTR-250*(A) 72 BTR-251*(A) 75 BTR-275*(A) 72 BTR-305 (A) 75 BTR-365 (A) MODEL 79-1/2 BTR-400 (A)BTR-500 75-1/2 BTR-500 (A) 81-1/2 4-1/4 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 17-1/2 66-1/2 62 70 70 62 65-1/8 65-1/8 65-3/4 65-1/8 65-3/4 70-1/4 67-1/2 77-1/4 57-7/8 53-5/8 61-5/8 61-5/8 53-5/8 55-7/8 55-7/8 57-1/4 55-7/8 57-1/4 62-1/2 58-1/4 67-1/2 19-11/16 20-1/2 20-1/2 20-1/2 20-1/2 19-3/4 19-3/4 20 19-3/4 20 22-1/2 26-3/4 27 19 21 21 21 21 23 23 N/A 23 N/A 23 23 21 BTR-120* BTR-154 OUTLET C H D INLET J E B A G 1˝ CLEARANCE GAS CONNECTION MODEL BTR-120-400 TOP INLET TOP OUTLET Model Number F Master-Fit BTR 500 G H I J Standard ASME BTR-120* 1/2 51-7/8 6 27-3/4 400 - BTR-154 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 1 59 54-5/8 62-5/8 61-1/2 54-5/8 56-3/8 56-3/8 58-3/4 56-3/8 58-3/4 63 59 67-1/2 6 6 6 6 6 8 8 8 8 8 8 8 8 27-3/4 27-3/4 27-3/4 27-3/4 27-3/4 30-1/4 30-1/4 27-3/4 30-1/4 27-3/4 27-3/4 30-1/4 27-3/4 470 470 603 603 470 630 630 750 630 750 725 760 812 725 725 862 725 862 833 874 857 BTR-180 INDUCED DRAFT MOTOR BTR-197 I BTR-198 BTR-199 BTR-200(A) BTR-250*(A) BTR-251*(A) BTR-275*(A) A BTR-305 (A) BTR-365 (A) BTR-400 (A) BTR-500 (A) MODEL R-120-400 78 MODEL BTR-500 Approx. Shipping Weight (lbs) Dimensions in Inches Specify when ordering propane (LP) gas. *Model BTR 120 is shipped with 6” x 5” flue outlet adapter. Models BTR 250, 251 and 275 are shipped with a 8” x 6” flue outlet adapter. Standard models certified from sea level to 2,000 ft. elevation. Order SMR S54 for elevations up to 8,000 ft. BTR-500 model features induced draft design and no damper. 79 COMMERCIAL GAS MASTER-FIT® BTR BOOSTER THE ELIMINATOR™ Self-Cleaning System 1-1/2" NPI OUTLET 1" NPI RELIEF VALVE OPENING H 15.2cm • Designed to significantly reduce or eliminate buildup of lime, sand and other sediment inside the tank • Reduced sediment buildup helps Master-Fit water heaters maintain their rated energy efficiency and reduce water heating costs • Self-cleaning system also helps prolong tank life Built-in Induced Draft Blower • Produces power-induced draft of makeup air prior to burner ignition • Provides more efficient control of heat through the flue collector • No draft hood or barometric damper required A B D C E G F Rated as a Category 1 Appliance • Can be commonly vented with other Category 1 appliances, using standard metal type “B” vent Three-Year Limited Warranty • For complete warranty information go to hotwater.com 1.5 3.8cm 1-1/2" NPI INLET Model Number CLEARANCE Gallon Capacity BTU Input Per Hour Recovery Capacity GPH @ 100°F Rise BTR-151 32 150,000 145 BTR-201 32 199,900 194 Dimensions in Inches Model Number BTR-151* & BTR-201 A B C D E F G 45 40 27-3/4 32-1/4 15-3/4 5 6-1/2 H 6 Approx. Shipping Weight (lbs) STD/ASME 440/460 Specify when ordering propane (LP) gas. A 6” x 8” vent reducer is provided with each unit. Certified for 6” or 8” venting. See local codes. *Booster models are induced draft with no damper. Height is to the top of the blower motor. Electrical characteristics- 120V-60 Hz A.C., 5.0A. “A” after the model numbder designates ASME construction. Leg Kits for UL Sanitation to meet NSF-5. Part # 9003425205 Uses standard metal single wall or double wall type B vent. 80 81 COMMERCIAL GAS MASTER-FIT® ULTRA-LOW NOx 80% Thermal Efficiency means Lower Operating Costs Fan Assisted Combustion • The blower is built into the low NOx burner assembly • Complies with California SCAQMD Rule 1146.2 and other Air Quality Management Districts with similar NOx emission requirements of 14 ng/J or 20 ppm Air-Flapper • A stainless steel air flapper is used inside the premix system to replace externally mounted flue damper to minimize the standby heat loss and to minimize the overall heater height Metal Venting • Rated Category I Appliance. Uses standard double wall type “B” vent. • Can be commonly vented with other Category I appliances • Vent connects directly to the vent connector outlet • An excellent choice for retrofit and upgrade installations 3-Year Limited Tank/1-Year Limited Parts Warranty Model Number BTL-120 BTL-154 BTL-180 BTL-198 BTL-199 BTL-250 BTL-275 BTL-310 BTL-366 BTL-400 BTL-250A BTL-275A BTL-310A BTL-366A BTL-400A Gallon Capacity Input BTU/HR Recovery Capacity GPH @ 100°F Rise 81 81 81 81 100 100 100 86 86 86 100 100 86 86 86 120,000 154,000 180,000 199,000 199,000 250,000 275,000 310,000 366,000 390,000 250,000 275,000 310,000 366,0000 390,000 115 148 173 191 191 240 264 298 352 375 240 264 298 352 375 Electrical characteristics—120V-60 Hz A. C., 5.0A. (A) after model number designates ASME construction. LEG KITS FOR UL SANITATION TO MEET NSF-5 (increases overall height by 4”). BTL models not available in LP gas. BTL models for sale in California only. • For complete warranty information, consult written warranty or go to hotwater.com. Line drawings and dimensions on the following page. 82 83 COMMERCIAL GAS MASTER-FIT® BTL ULTRA-LOW NOx (CONTINUED) ROUGH IN DIMENSIONS: MASTER-FIT BTL 199 ULN BTL-120, 154, 180, 198 K Letter F BTL-199, 250(A), 275(A) BTL-310(A), 366(A), 400(A) Dimensions in Inches TOP OUTLET 1 1/2 NPT 63-3/4 37 65 52-3/4 20-3/4 21 A TOP INLET 1 1/2 NPT B C AC D B H DH LE F 71-3/4 37 73 60-3/4 20-1/2 21 3/4 NPT 61 6 27-3/4 1-1/2 NPT 1-1/2 NPT G 53 6 27-3/4 H I E J TOP VIEW K DIMENSIONS: MASTER-FIT BTL 199 ROUGH ULN IN DIMENSIONS: MASTER-FIT BTL 199 ULN BACK VIEW I F F OP OUTLET 1 1/2 NPT TOP INLET 1 1/2 NPT ASME TOP OUTLET 1 1/2 NPT TOP INLET 1 1/2 NPT G L B 61 6 27-3/4 BTL-120, 154, 180, 198 BTL-199, 250(A), 275(A) BTL-310(A), 366(A), 400(A) 650 N/A 750 800 810 860 K Electrical characteristics—120V-60 Hz A. C., 5.0A. (A) after model number designates ASME construction. LEG KITS FOR UL SANITATION TO MEET NSF-5 (increases overall height by 4”). BTL models not available in LP gas. BTL models for sale in California only. L E TOP VIEW J FRONT VIEW 84 H DH Approx. Shipping Weight (lbs) Standard K AC B L 71-3/4 37 73 60-3/4 20-1/2 21 TOP VIEW BACK VIEW BACK VIEW 85 T&P VALVE COMMERCIAL GAS CONSERVATIONIST® BT E *TEMPERATURE AND PRESSURE RELIEF VALVE C COLD HOT H G Glasslined Tank J DRAIN VALVE • Maximizes tank life. B DRAIN VALVE ANODE ROD L GAS INLET • Fully Automatic Controls with Safety Shutoff A • Accurate, dependable control system requires no electric connections. Fixed automatic gas shutoff device for added safety. Not recommended for C L 180°F sanitizing. C Heavy Gauge Steel Jacket *INSTALL IN ACCORDANCE WITH LOCAL CODES. F K K HOT WATER OUTLET L D COLD WATER INLET T&P VALVE • Finished with baked enamel over bonderized M undercoat. Foam Insulation *TEMPERATU AND PRESSU RELIEF VALV • Saves fuel, helps reduce standby heat loss. • Low NOx C Complies with Texas and other Districts Requirements for NOx Emissions Less than 40 ng/j G J DRAIN VALV A • Completely factory-assembled. Only gas, water and vent connections need be made. All connections are located in front and top of heaters for ease of installation and service. CL CL 3-Year Limited Tank / 1-Year Limited Parts Warranty D M • For complete warranty information, consult written warranty or go to hotwater.com. Gallon Capacity Input Rating BTU/HR Recovery Capacity GPH @ 100°F Rise Approx. Shipping Weight (lbs) BT-100 74 98 75,100 75,100 73 73 275 350 Model Number A B C D E F 61-1/8 68-5/8 58-1/2 66-1/2 26-1/2 27-3/4 15-3/16 15-3/16 16 16 4 4 G H J K L M 14-1/2 15-3/4 29-11/16 30-15/16 54-1/4 54-1/4 1 1 1/2 1/2 11-15/16 11-15/16 Model Number BT-80 BT-80 BT-100 Model Number BT-80 BT-100 86 B DRAIN VALVE Easy-to-Install Dimensions in Inches Dimensions in Inches NSF leg kit 9006645005. Specify when ordering (LP) gas. 87 COMMERCIAL GAS INDUCED DRAFT LOW NOx BTN POWER VENT ROUGH-IN DIMENSIONS SIDE VIEW OF BTN Models 120-400 TOP VIEW OF BTN Induced Draft Built-in Blower • The blower is built into the top cover, factory mounted and wired. Ideal for installations where negative pressure is present in the building. • Blower proves draft prior to ignition. • No draft hood or barometric damper required. Rated Category I Appliance. • Uses standard metal single wall or double wall type “B” vent. Can be commonly vented with other Category I appliances. Vent connects directly to the blower outlet. Perfect choice for retrofit and upgrade installations. Water Connections • For ease of installation, all BTNs feature water connections on the top, front, and rear. 3-Year Limited Tank and 1-Year Limited Parts Warranty • For complete warranty information consult written warranty or go to hotwater.com. Model Number BTN-120+ BTN-154 BTN-180 BTN-199 BTN-200 (A) BTN-250 (A) BTN-275 (A) BTN-310 (A) BTN-366 (A) BTN-400 (A) 88 Gallon Capacity 71 81 100 100 100 100 100 85 85 85 Recovery Capacity GPH @ 100°F Rise Input BTU/HR Natural Gas 115 148 173 191 191 240 264 297 351 374 120,000 154,000 180,000 199,000 199,000 250,000 275,000 310,000 366,000 390,000 Approx. Shipping Weight (lbs) 520 550 550 550 660 660 660 720 830 830 Dimensions in Inches Model Number A B C D E BTN-120+ 63 4-1/4 59-1/2 50-7/8 19-5/8 BTN-154 TOP VIEW OF BTN 68 4-1/2 62 53-5/8 20-1/2 BTN-180 72 4-1/2 70 61-5/8 20-1/2 BTN-199 72 4-1/2 70 61-5/8 20-1/2 BTN-200 (A) 72 4-1/2 70 61-5/8 20-1/2 BTN-250 (A) 72 4-1/2 70 61-5/8 20-1/2 BTN-275 (A) 72 4-1/2 70 61-5/8 20-1/2 BTN-310 (A) 73 4-1/2 72 62-1/2 22-1/2 BTN-366 (A) 73 4-1/2 72 62-1/2 22-1/2 BTN-400 (A) 73 4-1/2 72 62-1/2 22-1/2 Model Number F G H I J BTN-120+ 19 3/4 51-7/8 6 27-3/4 BTN-154 21 3/4 54-5/8 6 27-3/4 BTN-180 21 3/4 61 6 27-3/4 BTN-199 21 3/4 61 6 27-3/4 BTN-200 (A) 21 3/4 61 6 27-3/4 BTN-250 (A) 21 3/4 61 6 27-3/4 BTN-275 (A) 21 3/4 61 6 27-3/4 BTN-310 (A) 21 3/4 63 6 27-3/4 BTN-366 (A) 21 1 63 6 27-3/4 BTN-400 (A) 21 1 63 6 27-3/4 Dimensions in Inches Electrical characteristics-120V-60 Hz A.C., 5.0A. “A” after model number designates ASME construction. Leg Kits for UL Sanitation meet NSF-5. Not available in propane (LP) gas. +BTN-120 is approved for 5” vent using a 6” x 5” reducer. Leg Kit for BTN-120 through 400 Part No. 9003425205. Standard models certified from sea level to 2,000 ft. elevations. Order SMR S54 for elevations up to 8,000 ft. 89 COMMERCIAL GAS CONSERVATIONIST® POWER VENT Approval Rating and Certification • All models comply with ANSI Z21.10.3/CSA 4.3 and ASHRAE/IES 90.1-2004 • Meets Texas and other low NOx areas requiring 40 ng/J ANODE D • All models are approved for use in combined appliance applications. COLD HOT CFC Free Foam Insulation • Minimize radiant heat loss Dip Tube • Carries inlet water deep into the tank Hot Surface Ignition • Has a solid state ignition surface that does not flutter or blow out • Provides increased reliability and efficiency over spark ignition systems. Eliminates the pilot and saves energy User-Friendly • State-of-art electronic gas control provides more precise temperature control. Ø • LED control light displays operation status and diagnostics 3-Year Limited Tank/1-Year Limited Parts Warranty • For complete warranty information, consult written warranty or go to hotwater.com. Model Number Approx. Gallon Capacity Btuh Input Approx. Shipping Weight BTF-80 75 76,000 277 lbs Model Number BTF-80 Model Number BTF-80 90 Dimensions in inches A B C D 70-5/8 61-1/4 26 33-1/8 Dimensions in inches E F G H 11 13-1/4 53 15-1/4 Recovery capacity based on 81% thermal efficiency. Available in LP (Propane) gas. Can be installed up to 10,100 feet without alteration. 91 COMMERCIAL GAS CONSERVATIONIST® POWER DIRECT VENT DynaClean™ Diffuser Dip Tube • Helps reduce lime and sediment buildup and maximizes hot water output. Made from long-lasting PEX cross-linked polymer Blue Diamond® Glass Coating • Provides superior corrosion resistance compared to C the industry-standard glasslining. D A Hot Surface Ignition B • Has a solid state ignition surface that does not flutter or blow out G • Provides increased reliability and efficiency over spark ignition systems. Eliminates the pilot and saves energy. Standards • Design-certified by CSA International, according to ANSI Z21.10.3-CSA 4.3 standards governing F storage-type water heaters. E H • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. 3-Year Limited Tank/1-Year Limited Parts Warranty • For complete warranty information, consult written warranty or go to hotwater.com C A B ® G F Model Number E Approx. Gallon Capacity Btuh Input Approx. Shipping Weight (lbs) 75 76,000 277 BPD-80 Model Number BPD-80 92 H Dimensions in Inches A B 70-5/8 61-1/4 C D E F G H 26 33-1/8 11 13-1/4 53 15-1/4 Specify when ordering propane (LP) gas. Can be installed up to 10,100 feet without alteration. Recovery capacity based on 81% thermal efficiency. 93 K HOT WATER OUTLET COMMERCIAL GAS F ® CONSERVATIONIST ULTRA-LOW NOx K COLD WATER INLET TOP VIEW H J TEMPERATURE AND PRESSURE RELIEF VALVE DRAIN Code Compliance VALVE • The Ultra-Low NOx atmospheric vent commercial D gas water heater which meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and Current Edition ASHRAE/IESNA 90.1. A Fully Automatic Controls with Safety Shutoff C COLD HOT G B DRAIN VALVE K HOT WATER OUTLET L GAS INLET • Accurate, dependable control system requires no E electric connections. Fixed automatic gas shutoff M device for added safety. Not recommended for 180˚ F sanitizing. K COLD WATER INLET F J Heavy Gauge Steel Jacket FRONT VIEW • Finished with baked enamel over bonderized undercoat DRAIN VALVE Foam Insulation D • Saves fuel, helps reduce standby heat loss. Ultra-Low NOx Emissions B • Complies with SCAQMD Rule 1146.2 and other Air Quality Management Districts with similar requirements of 14 ng/J or 20 ppm. A Easy-to-Install • Completely factory-assembled. Only gas, water and vent connections need to be made. All connections are located in front and top of heaters for ease-of-installation and service. E M 3-Year Limited Tank and 1-Year Limited Parts Warranty • For complete warranty information, consult written warranty or go to hotwater.com FRONT VIEW Gallon Capacity Input BTU/hr Recovery Capacity GPH @ 100°F Rise Approx. Shipping Weight (lbs) BL-80 ** 74 75,100 73 285 BL-100* 98 75,100 74 350 Model Number Dimensions in Inches Model Number BL-80 ** BL-100* A B C D E 62-1/16 70-1/2 58 66-1/2 29-1/2 30-15/16 25-1/4 27-3/4 15-7/8 15-3/16 Dimensions in Inches Model Number BL-80 ** BL-100* 94 F G H J K L M 4 4 15-1/4 15-3/4 16 16 2 1-1/4 1 1-1/4 1/2 1/2 12-1/2 11-15/16 Natural gas only. *Recovery rating based on 81% thermal efficiency **Recovery rating based on 80% thermal efficiency 95 COMMERCIAL GAS POWER BURNER LIGHT DUTY D 19.00 Power Gas Burner H • Electronic flame safeguard control with direct spark ignition • Redundant gas valves for added safety • Power gas burner requires 120V, 60Hz service ROUGH IN DIMENSIONS - Models BTP-139(A) Thru BTP-370(A) 64.93" • Non-forced-draft burner; negative draft required in vent piping BAROMETRIC DRAFT CONTROL ASSEMBLY Fully Automatic Controls with Safety Shutoff • High temperature limit control (manual reset) INLET & DIP TUBE OUTLET • Dual thermostats for accurate temperature control Glass Coating HI T’STAT OUTLET • Exclusive process provides superior protection against corrosion T&P 3-Year Limited Tank and 1-Year Limited Parts Warranty • For complete warranty information, consult written warranty or go to hotwater.com G J A LO’ TSTAT INLET B CLEANOUT 34.75" INSPECTION POWER BURNER ASSEMBLY C 24.75" E Model Number BTU Input Per Hour Tank Size GPH BTP-139(A) 140,000 199,000 270,000 370,000 81 81 81 81 GPH GPH GPH GPH BTP-199(A) BTP-270(A) BTP-370(A) Recovery Gallons Per Hour Temperature Rise 100° Maximum Amperes 120V, 60 Hz, 1 136 193 262 359 5 5 5 5 Model Number BTP-139(A) BTP-199(A) BTP-270(A) BTP-370(A) Model Number BTP-139(A) BTP-199(A) BTP-270(A) BTP-370(A) 96 Dimensions in Inches A B C D E 74-3/4 74-3/4 74-3/4 74-3/4 65 65 65 65 26-3/4 26-3/4 26-3/4 26-3/4 6 6 6 6 21-3/8 21-3/8 21-3/8 21-3/8 Dimensions in Inches Approx. Shipping Weight G H J Standard ASME 27-3/4 27-3/4 27-3/4 27-3/4 38 38 38 38 85-1/4 85-1/4 85-1/4 85-1/4 556 lbs 545 lbs 547 lbs 547 lbs 658 lbs 635 lbs 632 lbs 632 lbs 97 COMMERCIAL GAS LOW NOx POWER BURNER Venting Options 1-1/2" INLET & DIP TUBE 1-1/2" OUTLET • BTP models designed for conventional atmospheric vertical venting. Barometric draft regulating damper provided. Order Vent Kit Part #9500007350. I • BTPV models designed for horizontal atmospheric sidewall venting or direct venting. D 1-1/2" NPT OUTLET OPENING (FRONT & BACK) • For sidewall venting order Vent Kit Part #950007229. 1" NPT T&P VALVE OPENING • For direct venting order Vent Kit Part #9910001005. Low NOx Power Gas Burner (Natural Gas Only) • Pre-mix design with internal Flue Gas Recirculation (FGR) • Safety features include internal blocked flue sensor, separate pilot system, internal thermal cutoff and anti-flashback barrier. G 1-1/2" NPT INLET OPENING (FRONT & BACK) E I H A B FLUE REDUCER SHIPPED W/VENT HOOD CLEANOUT OPENING 1-1/2" NPT OUTLET OPENING (FRONT & BACK) 1" NPT T&P VALVE OPENING C F Fully Automatic Controls 1-1/2" NPT INLET OPENING (FRONT & BACK) • Including safety shut-off, high-temperature limit control H A • Dual thermostat, adjust from 120˚F to 180˚F B 3-Year Limited Tank and 1-Year Limited Parts Warranty CLEANOUT OPENING Model Number BTP(V)-540A BTP(V)-650A BTP(V)-740A Gallon Input/BTU/HR Capacity Natural Gas 85 85 85 540,000 650,000 740,000 Recovery Capacity GPH @ 100°F Rise 523 630 718 Approx. Shipping Weight (lbs) 950 950 950 Not available in propane (LP). Vent Kit included in unit price. Authorizes start-up service included- required to activate warranty. Consult local factory representative (Continental U.S. only) C F • For complete warranty information, consult written warranty or go to hotwater.com Model Number BTP(V)-540A BTP(V)-650A BTP(V)-740A Model Number BTP(V)-540A BTP(V)-650A BTP(V)-740A Dimensions in Inches A B C D E 80-3/4 80-3/4 80-3/4 73 73 73 32-1/4 32-1/4 32-1/4 9 9 9 26-1/2 26-1/2 26-1/2 Dimensions in Inches F G H I 26-1/2 26-1/2 26-1/2 93 93 93 29-1/2 29-1/2 29-1/2 48-1/2 48-1/2 48-1/2 Not available in propane (LP). Vent Kit included in unit price. Authorizes start-up service included- required to activate warranty. Consult local factory representative (Continental U.S. only) 98 99 COMMERCIAL GAS CONSERVATIONIST® HIGH VOLUME POWER BURNER Power Gas Burner • Suitable for natural or propane gas • Electronic flame safeguard control with intermittent spark ignition Model Number • Main and pilot automatic gas valves with gas pressure regulators BTP-150-140 • Diaphragm air switch for proof of blower operation BTP-150-255 • Flame inspection port BTP-150-270 BTP-150-199 Fully Automatic Controls with Safety Shutoff BTP-150-400 • High-temperature limit control (manual reset) BTP-150-720 • CSA certified and ASME rated T&P relief valve BTP-200-300 • Hinged-door control compartment for accurate temperature control BTP-200-600 • Standard control is for 120o-180oF water service BTP-200-1000 • Factory-installed low-water cutoff BTP-200-1250 Blue Diamond® Glass Coating • Provides superior corrosion resistance compared to the industry-standard glasslining. Codes and Standards • Design-certified by UL (Underwriters Laboratories), according to ANSI Z21. 10.3-4.3 CSA Standards • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1 3-Year Limited Tank and 1-Year Limited Parts Warranty • -For complete warranty information, consult written warranty or go to hotwater.com BTP-150-540 BTP-200-800 BTP-200-1500 BTP-300-300 BTP-300-600 BTP-300-800 BTP-300-1000 BTP-300-1250 BTP-300-1500 BTP-400-600 BTP-400-800 BTP-400-1000 BTP-400-1250 BTP-400-1500 BTP-400-1750 BTP-400-2000 BTP-600-720 BTP-600-1000 BTP-600-1250 BTP-600-1500 BTP-600-1750 BTP-600-2000 BTP-600-2250 BTP-600-2500 Gallon Capacity Recovery Capacity GPH @ 100°F Rise Input BTU/ HR *Natural Gas Approx. Shipping Weight (lbs) 163 163 163 163 151 151 145 221 221 221 221 210 201 300 300 411 411 411 411 411 411 411 411 411 404 397 594 594 594 594 594 594 585 575 136 193 247 262 387 524 698 291 582 776 970 1212 1454 291 582 776 970 1212 1454 582 776 970 1212 1455 1697 1939 698 970 1212 1454 1697 1939 2182 2424 140,000 199,000 255,000 270,000 400,000 540,000 720,000 300,000 600,000 800,000 1,000,000 1,250,000 1,500,000 300,000 600,000 800,000 1,000,000 1,250,000 1,500,000 600,000 800,000 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000 720,000 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000 2,250,000 2,500,000 1292 1292 1292 1397 1397 1505 1510 2098 2098 2103 2103 2467 2757 2150 2150 2308 2308 2584 2774 3207 3212 3212 3212 3402 3528 3669 3667 3667 3667 3837 3837 3837 4477 4619 †Models with an (N) are available in low NOx (include the “N” in the model number when ordering) Specify when ordering propane (LP) gas. Authorized start-up service included-required to activate warranty. Consult local factory representative (Continental U.S. Only). Line drawings and dimensions on the following page. 100 101 COMMERCIAL GAS CONSERVATIONIST® HIGH VOLUME POWER BURNER (CONTINUED) Model Number Dimensions in Inches A B C G H J BTP-150-140 82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2 D E F 5 47 73-1/2 BTP-150-199 82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2 6 47 73-1/2 BTP-150-255 82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2 6 47 73-1/2 BTP-150-270 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 6 57-1/2 73-1/2 BTP-150-400 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 7 57-1/2 73-1/2 BTP-150-540 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 8 57-1/2 73-1/2 BTP-150-720 82-1/4 13-1/2 1-1/4 29-1/4 1-1/4 36-1/2 10 57-1/2 73-1/2 BTP-200-300 84-1/2 17-1/2 1 34-3/4 1-1/2 44-3/4 6 66-1/2 74-3/4 BTP-200-600 84-1/2 17-1/2 1 34-3/4 1-1/2 44-3/4 8 66-1/2 74-3/4 BTP-200-800 84-1/2 17-1/2 1-1/4 34-3/4 1-1/2 44-3/4 10 66-1/2 74-3/4 BTP-200-1000 84-1/2 17-1/2 1-1/4 34-3/4 1-1/2 44-3/4 10 66-1/2 74-3/4 BTP-200-1250 84-3/4 13-1/2 1-1/4 29-1/2 1-1/2 44-3/4 12 66-1/2 75 BTP-200-1500 84-3/4 13-1/2 1-1/2 29-1/2 1-1/2 44-3/4 12 81-1/2 75 BTP-300-300 92 14 1 29-1/4 1-1/2 44-3/4 6 66-1/2 82-1/2 BTP-300-600 92 14 BTP-300-800 92 14 1 29-1/4 1-1/2 44-3/4 8 66-1/2 81-1/2 1-1/4 29-1/4 1-1/2 44-3/4 10 BTP-300-1000 92 14 1-1/4 29-1/4 1-1/2 44-3/4 10 66-1/2 81-1/2 66-1/2 81-1/2 BTP-300-1250 92 14 1-1/4 29-1/4 1-1/2 44-3/4 12 66-1/2 81-1/2 BTP-300-1500 92 14 1-1/2 29-1/4 1-1/2 44-3/4 12 81-1/2 81-1/2 BTP-400-600 89 17-1/2 33-1/4 2 55 8 76-1/2 78-3/4 BTP-400-800 89 17-1/2 1-1/4 33-1/4 2 55 10 76-1/2 78-3/4 BTP-400-1000 89 17-1/2 1-1/4 33-1/4 2 55 10 76-1/2 78-3/4 BTP-400-1250 89 17-1/2 1-1/4 33-1/4 2 55 12 76-1/2 78-3/4 BTP-400-1500 89 17-1/2 1-1/2 33-1/4 2 55 12 91-1/2 78-3/4 BTP-400-1750 89 17-1/2 2 33-1/4 2 55 14 91-1/2 78-3/4 96-1/4 17-1/2 2 1 33-1/4 2 55 14 91-1/2 86-1/2 BTP-600-720 114 17-1/2 1-1/4 33-1/4 2 55 10 76-1/2 105 BTP-600-1000 114 17-1/2 1-1/4 33-1/4 2 55 10 76-1/2 105 BTP-600-1250 114 17-1/2 1-1/4 33-1/4 2 55 12 76-1/2 105 BTP-600-1500 114 17-1/2 1-1/2 33-1/4 2 55 12 91-1/2 105 BTP-600-1750 114 17-1/2 2 33-1/4 2 55 14 91-1/2 105 BTP-600-2000 114 17-1/2 2 33-1/4 2 55 14 91-1/2 105 BTP-600-2250 114 17-1/2 2 33-1/4 2 55 16 91-1/2 105 BTP-600-2500 114 17-1/2 2 33-1/4 2 55 14 91-1/2 105 BTP-400-2000 †Models with an (N) are available in low NOx (include the “N” in the model number when ordering) Specify when ordering propane (LP) gas. Authorized start-up service included-required to activate warranty. Consult local factory representative (Continental U.S. Only). 102 103 COMMERCIAL GAS CONSERVATIONIST® DURACLAD OIL-FIRED TANK-TYPE Efficient Combustion Chamber • Precast, high temperature combustion chamber made of alumina silica ceramic fiber. Engineered for maximum insulation and heat reflection. Unique design assures more complete combustion by stabilizing flame pattern. Interrupted Ignition • Reduces electrical consumption Two Hand-hole Cleanouts • Allows easy cleaning on standard models COF385 and larger and ASME models Easy-to-Install Burner • Three bolt mounting of burner assures easy installations. 3-Year Limited Tank and 1-Year Limited Parts Warranty • For complete warranty information consult written warranty or go to hotwater.com Dimensions in Inches Model Number A B C D E F COF-199 74-1/2 36-3/4 27-3/4 2 3/4 NPT 8 COF-245 74-1/2 36-3/4 27-3/4 2 3/4 NPT 8 COF-315 (A) 74-1/2 73-3/4 73-3/4 73-3/4 36-3/4 36-3/4 36-3/4 36-3/4 27-3/4 27-3/4 27-3/4 27-3/4 2 2 2 2 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 8 8 8 8 G H J K L COF-199 26-5/8 74-1/2 1-1/2 NPT 1-1/2 NPT 22-3/4 COF-245 26-5/8 74-1/2 1-1/2 NPT 1-1/2 NPT 22-3/4 26-5/8 COF-385 (A) 24-3/4 COF-455 (A) 24-3/4 COF-700 (A) 30-3/16 74-1/2 73-3/4 73-3/4 79-3/16 1-1/2 NPT 1-1/2 NPT 1-1/2 NPT 1-1/2 NPT 1-1/2 NPT 1-1/2 NPT 1-1/2 NPT 1-1/2 NPT 22-3/4 23-7/16 23-7/16 28-7/8 COF-385 (A) COF-455 (A) COF-700 (A) Available on COF-315 and higher Model Number COF-199 COF-245 COF-315 (A) COF-385 (A) COF-455 (A) COF-700 (A) 104 Model Number Recovery Approx. Shipping Gallon Input BTU/ Capacity Motor Weight (lbs) Capacity HR GPH @ 100°F HP Standard ASME Rise 86 86 84 75 75 69 199,000 245,000 315,000 385,000 455,000 700,000 191 235 302 369 436 671 1/8 1/8 1/8 1/8 1/8 1/8 553 554 554 624 700 739 N/A N/A 657 742 747 822 COF-315 (A) Dimensions in Inches *Based on No. 2 fuel oil. All models have 1/8 HP motor. Add “S” to the end of the model number for standard (COF-199S) and “A” to the end of the model number for ASME (COF-700A) tanks.. 105 COMMERCIAL GAS CUSTOM HEAVY-DUTY LARGE VOLUME OIL-FIRED Model Number Fully Automatic Controls with Safety Shutoff • High temperature limit control (manual reset). CSA Certified and ASME rated temperature and pressure relief valve. 163 140,000 136 163 199,000 193 COF-150-255 163 163 150 151 151 145 221 221 221 201 201 201 300 300 300 300 300 300 411 411 411 411 397 397 397 594 594 594 594 594 594 575 575 255,000 270,000 350,000 400,000 540,000 720,000 300,000 600,000 800,000 1,000,000 1,250,000 1,500,000 300,000 600,000 800,000 1,000,000 1,250,000 1,500,000 600,000 800,000 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000 720,000 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000 2,250,000 2,500,000 247 262 339 387 524 698 291 582 776 970 1212 1455 291 582 776 970 1212 1455 582 776 970 1212 1455 1697 1939 698 970 1212 1455 1697 1939 2182 2424 COF-150-270 • Two thermostats, upper and lower, for accurate temperature control. COF/COBT-150-540 COF/COBT-150-400 COF/COBT-150-720 • Heavy gauge steel jacket with baked powder coat finish. COF/COBT-200-300** • Insulated with high-density foam insulation that meets or exceed all required standards. COF/COBT-200-800 • Meets or exceeds the thermal efficiency and/or standby loss requirements of the U.S. COF/COBT-200-1250 • Department of Energy and current edition ASHRAE/ IESNA 90.1. COF/COBT-300-300** • -For complete warranty information consult written warranty or go to hotwater.com Recovery Capacity GPH @ 100°F Rise COF-150-140 COBT-150-350 3-Year Limited Tank and 1-Year Limited Parts Warranty Input Rating BTU/HR COF-150-199 • Hinged door control compartment with key lock for ease of access. Jacket and Insulation Gallon Capacity COF/COBT-200-600 COF/COBT-200-1000 COF/COBT-200-1500 COF/COBT-300-600 COF/COBT-300-800 COF/COBT-300-1000 COF/COBT-300-1250 COF/COBT-300-1500 COF/COBT-400-600 COF/COBT-400-800 COF/COBT-400-1000 COF/COBT-400-1250 COF/COBT-400-1500 COF/COBT-400-1750 COF/COBT-400-2000 COF/COBT-600-720 COF/COBT-600-1000 COF/COBT-600-1250 COF/COBT-600-1500 COF/COBT-600-1750 COF/COBT-600-2000 COF/COBT-600-2250 COF/COBT-600-2500 *COBT models are 350,000 BTU Natural Gas. Authorized start-up service included-required to activate warranty. Consult local factory representative. (Continental U. S. Only). Specify when ordering propane (LP) gas. Line drawings and dimensions on the following page. 106 107 COMMERCIAL GAS CUSTOM HEAVY-DUTY LARGE VOLUME OIL-FIRED (CONTINUED) Model Number Dimensions in Inches A B C G H J COF-150-140 82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2 D E F 5 47 73-1/2 COF-150-199 82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2 6 47 73-1/2 COF-150-255 82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2 6 47 73-1/2 COF-150-270 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 6 57-1/2 73-1/2 COBT-150-350 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 7 57-1/2 73-1/2 COF/COBT-150-400 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 7 57-1/2 73-1/2 COF/COBT-150-540 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 8 57-1/2 73-1/2 COF/COBT-150-720 82-1/4 13-1/2 1-1/4 29-1/4 1-1/4 36-1/2 10 57-1/2 73-1/2 COF/COBT-200-300 84-1/2 17-1/2 1 34-3/4 1-1/2 44-3/4 6 66-1/2 74-3/4 COF/COBT-200-600 84-1/2 17-1/2 1 34-3/4 1-1/2 44-3/4 8 66-1/2 74-3/4 COF/COBT-200-800 84-1/2 17-1/2 1-1/4 34-3/4 1-1/2 44-3/4 10 66-1/2 74-3/4 COF/COBT-200-1000 84-1/2 17-1/2 1-1/4 34-3/4 1-1/2 44-3/4 10 66-1/2 74-3/4 COF/COBT-200-1250 84-3/4 13-1/2 1-1/4 29-1/2 1-1/2 44-3/4 12 66-1/2 75 COF/COBT-200-1500 84-3/4 13-1/1 1-1/4 29-1/2 1-1/2 44-3/4 12 81-1/2 75 COF/COBT-300-300 92 14 COF/COBT-300-600 92 14 COF/COBT-300-800 92 14 1-1/4 29-1/4 1-1/2 44-3/4 10 66-1/2 81-1/2 COF/COBT-300-1000 92 14 1-1/4 29-1/4 1-1/2 44-3/4 10 66-1/2 81-1/2 COF/COBT-300-1250 92 14 1-1/4 29-1/4 1-1/2 44-3/4 12 66-1/2 81-1/2 COF/COBT-300-1500 92 14 1-1/4 29-1/4 1-1/2 44-3/4 12 81-1/2 81-1/2 COF/COBT-400-600 89 17-1/2 33-1/4 2 55 8 COF/COBT-400-800 89 17-1/2 1-1/4 33-1/4 2 55 10 76-1/2 78-3/4 COF/COBT-400-1000 89 17-1/2 1-1/4 33-1/4 2 55 10 76-1/2 78-3/4 COF/COBT-400-1250 89 17-1/2 1-1/4 33-1/4 2 55 12 76-1/2 78-3/4 COF/COBT-400-1500 89 17-1/2 1-1/4 33-1/4 2 55 12 91-1/2 78-3/4 COF/COBT-400-1750 89 17-1/2 2 33-1/4 2 55 14 91-1/2 78-3/4 COF/COBT-400-2000 96-1/4 17-1/2 2 33-1/4 2 55 14 91-1/2 86-1/2 114 17-1/2 1-1/4 33-1/4 2 55 10 76-1/2 108 COF/COBT-600-1000 114 17-1/2 1-1/4 33-1/4 2 55 10 76-1/2 105 COF/COBT-600-1250 114 17-1/2 1-1/4 33-1/4 2 55 12 76-1/2 105 COF/COBT-600-1500 114 17-1/2 1-1/2 33-1/4 2 55 12 91-1/2 105 COF/COBT-600-1750 114 17-1/2 2 33-1/4 2 55 14 91-1/2 105 COF/COBT-600-2000 114 17-1/2 2 33-1/4 2 55 14 91-1/2 105 COF/COBT-600-2250 114 17-1/2 2 33-1/4 2 55 16 91-1/2 105 COF/COBT-600-2500 114 17-1/2 2 33-1/4 2 55 16 91-1/2 105 COF/COBT-600-720 1 29-1/4 1-1/2 44-3/4 6 66-1/2 81-1/2 1 29-1/4 1-1/2 44-3/4 8 66-1/2 81-1/2 1 76-1/2 78-3/4 *COBT models are 350,000 BTU Natural Gas. Authorized start-up service included-required to activate warranty. Consult local factory representative. (Continental U. S. Only). Specify when ordering propane (LP) gas. 108 109 COMMERCIAL GAS TANKLESS NON-CONDENSING INDOOR MODEL 13-3/4" (350mm) 10" (254mm) 4" (101 mm) 13-3/4" (350mm) 10" (254mm) 1-3/4" (45mm) 1-3/4" (45mm) 4-3/8" (113mm) 1-3/4" (45mm) Maximum Flow Rates up to 10.0 GPM 1-7/8" (47mm) HOT 5-1/4" (133mm) 1-7/8" (47mm) 120V 1-3/8" (36mm) COLD 3-1/4" (84mm) GAS 4-7/8" (124mm) 120V 1-3/8" (36mm) HOT 5-1/4" (133mm) GAS 4-7/8" (124mm) • Includes a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting 1-5/8" (43mm) 20-1/4" (520mm) • Air-Fuel Ratio (AFR) Sensor 21-3/8" (544mm) Safety Features 20-1/4" (520mm) • Easy-Link up to 4 units 21-3/8" (544mm) ATI-510 & ATO-510 Can Be Used In Both Residential and Commercial Applications 1-5/8" (43mm) 4-3/8" (113mm) 4-3/8" (113mm) 19-3/8" (493mm) Low NOx Emissions OUTDOOR MODEL 13-3/4" (350mm) 13-3/4" (350mm) 10" (254mm)10" (254mm) 7-7/8" (203mm) 7-7/8" (203mm) 1-3/4" (45mm) 1-3/4" (45mm) 1-3/4" (45mm) 1-3/4" (45mm) 5" (128mm) 5" (128mm) 1-5/8" (43mm) Factory-Installed Power Cord Included For Indoor Models 1" (26mm) COLD 2-7/8" (71mm) 1" (26mm) 120VAC 3-7/8" (99mm) COLD 2-7/8" (71mm) GAS 5-1/4" (135mm) 120VAC 3-7/8" (99mm) HOT 6-1/2" (164mm) GAS 5-1/4" (135mm) 9-1/2" (241mm) HOT 6-1/2" (164mm) 9-1/2" (241mm) 19-3/8" (493mm) Indoor/Outdoor Models COLD 3-1/4" (84mm) 19-3/8" (493mm) 20-1/4" (520mm) 21-3/8" (544mm) 19-3/8" (493mm) 1-3/8" (36mm) 20-1/4" (520mm) • Primary heat exchanger of the ATI/ATO-510 is constructed of a commercial-grade copper that is more resilient to erosion. Copper is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperatures quicker and reducing pressure drop across the heat exchanger 1-3/8" (36mm) 21-3/8" (544mm) Copper Primary Heat Exchanger 4-3/8" (113mm) 4" (101 mm) 1-3/4" (45mm) • Exhaust & Water Temperature Safety Control • Overheat cut-off fuse Internal Freeze Protection Power Vent or Power Direct Vent Design 1" (26mm) 1" (26mm) 2-7/8" (71mm) COLD 2-7/8"COLD (71mm) 120VAC 3-7/8" (99mm) 120VAC 3-7/8" (99mm) GAS 5-1/4" (135mm) GAS 5-1/4" (135mm) 1-3/8" (36mm) 120V 1-3/8" 120V (36mm) HOT 6-1/2" (164mm) HOT 6-1/2" (164mm) GAS 4-7/8" (124mm) 9-1/2" (241mm) GAS 4-7/8" (124mm) 9-1/2" (241mm) 1-7/8" (47mm) 1-7/8" (47mm) 3-1/4" (84mm) COLD 3-1/4"COLD (84mm) HOT 5-1/4" (133mm) HOT 5-1/4" (133mm) Warranty 510 Models • 15-year limited warranty on heat exchanger in residential applications. • 10-year limited warranty on heat exchanger in commercial applications. ANSI Z21.10.3 CSA 4.3 • 5-year warranty on all parts. Model Number* Type Inlet Gas Pressure Maximum Minimum Maximum BTU/H in. W.C. in.W.C. Energy Factor (EF) Hot/Cold Gas Connections Connection Indoor Models ATI-510-N Natural 199,000 Model Type Number* 5.0 10.5 0.82 Sizing Chart (Number of Showers) 3/4” NPT 3/4” NPT Clearance (Inches) Cold Climate** Warm Climate*** Top 2.5 3.5 12 Bottom Side Front Back Indoor Models ATI-510-N 110 Natural 12 2 4 *For propane models, change “N” to “P” in the model number (example:ATI-510-P) For outdoor models change “I” to “O” in the model number (example: ATO-510-N). **Cold climate represents 70°F temperature rise ***Warm climate represents 50°F temperature rise 0.5 111 COMMERCIAL GAS TANKLESS NON-CONDENSING ULTRA-LOW NOx INDOOR MODEL 13-3/4" (350mm) 10" (254mm) 1-3/4" (45mm) 4" (101 mm) 13-3/4" (350mm) 10" (254mm) 1-3/4" (45mm) 4-3/8" (113mm) 4" (101 mm) 4-3/8" (113mm) 1-3/4" (45mm) 1-3/4" (45mm) 1-3/8" (36mm) 19-3/8" (493mm) 19-3/8" (493mm) Maximum Flow Rates Up To 10.0 GPM 20-1/4" (520mm) 21-3/8" (544mm) 20-1/4" (520mm) 21-3/8" (544mm) • Complies with SCAQMD 1146.2 NOx emission requirements of 14 ng/J or 20 PPM. 1-5/8" (43mm) 1-3/8" (36mm) Ultra-Low NOx Emissions Copper Primary Heat Exchanger HOT 5-1/4" (133mm) 1-7/8" (47mm) 120V 1-3/8" (36mm) COLD 3-1/4" (84mm) GAS 4-7/8" (124mm) 120V 1-3/8" (36mm) HOT 5-1/4" (133mm) GAS 4-7/8" (124mm) OUTDOOR MODEL Safety Features • Air-fuel ratio (AFR) Sensor. 4-3/8" (113mm) 7-7/8" (203mm) 1-3/4" (45mm) 5" (128mm) 4-3/8" (113mm) 1-7/8" (47mm) COLD 3-1/4" (84mm) 120V 1-3/8" (36mm) HOT 5-1/4" (133mm) GAS 4-7/8" (124mm) 19-3/8" (493mm) 1-5/8" (43mm) 7-7/8" (203mm) 1-3/4" (45mm) 5" (128mm) 20-1/4" (520mm) 21-3/8" (544mm) • Multi-Link Up to 20 Units. 20-1/4" (520mm) • Easy-Link Up To 4 Units. 13-3/4" (350mm) 10" (254mm) 1-3/4" (45mm) 21-3/8" (544mm) ATI-510U / ATO-510U Can be Used in Both Residential and Commercial Applications 13-3/4" (350mm) 10" (254mm) 1-3/4" (45mm) 19-3/8" (493mm) Indoor/Outdoor Models • Include a Wall Mount Temperature Remote Controller and Advanced Diagnostics to Simplify Troubleshooting. 1" (26mm) COLD 2-7/8" (71mm) 1" (26mm) 120VAC 3-7/8" (99mm) COLD 2-7/8" (71mm) GAS 5-1/4" (135mm) 120VAC 3-7/8" (99mm) HOT 6-1/2" (164mm) GAS 5-1/4" (135mm) 9-1/2" (241mm) HOT 6-1/2" (164mm) 9-1/2" (241mm) 1-7/8" (47mm) COLD 3-1/4" (84mm) 1-5/8" (43mm) • Primary heat exchange of the ATI/ATO-510U is constructed of a commercial-grade copper that is more resilient to erosion. Copper is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperatures quicker and reducing pressure drop across the heat exchanger indoor and outdoor models available. 1" (26mm) COLD 2-7/8" (71mm) 120VAC 3-7/8" (99mm) GAS 5-1/4" (135mm) HOT 6-1/2" (164mm) 9-1/2" (241mm) 1" (26mm) COLD 2-7/8" (71mm) 120VAC 3-7/8" (99mm) GAS 5-1/4" (135mm) HOT 6-1/2" (164mm) 9-1/2" (241mm) • Exhaust & Water Temperature Safety Control. • Overheat cut-off fuse. 1-7/8" (47mm) COLD 3-1/4" (84mm) 120V 1-3/8" (36mm) HOT 5-1/4" (133mm) GAS 4-7/8" (124mm) Internal Freeze Protection Power Vent or Power Direct Vent Design Warranty • 15-year limited warranty on heat exchanger in residential applications. • 5-year limited warranty on heat exchanger in commercial applications. ANSI Z21.10.3 CSA 4.3 Model Number* Type Inlet Gas Pressure Maximum Minimum Maximum BTU/hr in. W.C. in.W.C. Energy Hot/Cold Gas Factor Connections Connection (EF) Indoor Models ATI-510U-N Natural 199,000 • 5-year limited warranty on all parts. Model Number* Type 5.0 10.5 Sizing Chart (Number of Showers) 0.82 3/4” NPT 3/4” NPT Clearance (Inches) Cold Climate** Warm Climate*** Top Bottom 2.5 3.5 12 12 Side Front Back Indoor Models ATI-510U-N Natural 112 2 4 *For propane models, change “N” to “P” in the model number (example:ATI-510-P) For outdoor models change “I” to “O” in the model number (example: ATO-510-N). **Cold climate represents 70°F temperature rise ***Warm climate represents 50°F temperature rise 0.5 113 COMMERCIAL GAS TANKLESS CONDENSING HIGH EFFICIENCY Maximum Flow Rates up to 10.0 GPM Indoor Models • Include integrated temperature controls and advanced diagnostics to simplify troubleshooting. • Include factory-installed power cords Outdoor Models • Include a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting. Common Vent Indoor Models up to 8 Units 22-1/2" (570 mm) 1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (140 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 120 VAC 6-7/8" (174 mm) Condens ate drain port 7-7/8" (199 mm) COLD 5/8" (17 mm) 120 VAC 3" (77 mm) GAS 5-3/4" (147 mm) Condens ate drain port 7-1/2" (189 mm) OUTDOOR MODEL Condens ate drain port 7-1/2" (189 mm) GAS 5-7/8" (147 mm) 120 VAC 3" (77 mm) OUTDOOR MODEL HOT 4-3/4" (120 mm) 17-5/8" (448 mm) 17-3/4" (450 mm) 7" (180 mm) 11-1/4" (285 mm) 4-1/2" (114 mm) 11" (281 mm) 6-1/4" (159 mm) COLD 5/8" (17 mm) 10-3/4" (272 mm) HOT 4-3/4" (120 mm) 120 VAC 6-1/4" (159 mm) Drain port 6-3/4" (170 mm) 1/2" (13 mm) 120 VAC 3" (77 mm) GAS (131 mm) HOT (140 mm) Drain port 6" (152 mm) COLD 5/8" (17 mm) GAS 5-3/4" (147 mm) Condens ate drain port 7-1/2" (189 mm) COLD 6-3/4" (172 mm) Condens ate drain port 7-7/8" (199 mm) Can be used in both Residential and Commercial Applications • Exhaust & Water Temperature Safety Control. • Overheat Cut-off Fuse. Internal Freeze Protection System Power Vent or Power Direct Vent Design Warranty • 15-year limited warranty on heat exchanger in residential applications. • 10-year limited warranty on heat exchanger in commercial applications. 114 • 5-year limited warranty on all parts. Inlet Gas Pressure Energy Maximum Hot/Cold Gas 17-5/8" (448 mm) Minimum Maximum Factor BTU/H Connections Connection (EF) in. W.C. in. W.C. Indoor Models ATI-540H-N Natural 120 VAC 6-1/4" (159 mm) Model Number* Type 199,000 COLD 6-3/4" (172 mm) • Air-Fuel Ration (AFR) Sensor. Type 5.0 Condensate drain port 7-7/8" (199 mm) CSA 4.3 Model Number* Condens ate drain port 7-1/2" (189 mm) GAS 5-1/8" (131 mm) ANSI Z21.10.3 Safety Features HOT 4-3/4" (120 mm) 120 VAC 3" (77 mm) • Multi-Link up to 20 units. HOT 5-1/2" (140 mm) • Easy-Link up to 4 units. Intake 2-5/8" (68 mm) Exhaust 2-5/8" (65 mm) 24-7/8" (631 mm) 23-5/8" (600 mm) HOT 4-3/4" (120 mm) Drain port 6-3/4" (170 mm) 5-3/4" (147 mm) • Secondary heat exchanger is made of marinegrade 316L stainless steel to protect against corrosion. 10-3/4" (272mm) 22-1/2" (570 mm) • Primary heat exchanger of the ATI/ATO-540 is constructed of a commercial-grade copper that is more resilient to erosion. Copper is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperature quicker and reducing pressure drop across the heat exchanger. 5-3/4" (147 mm) GAS 5-1/8" (131 mm) 3-5/8" (92 mm) COLD 6-3/4" (172 mm) 1-1/2" (37 mm) Condensate drain port 7-7/8" (199 mm) Heat Exchanger 4" (102 mm) Female 120 VAC 6-7/8" (174 mm) • Complies with SCAQMD 1146.2 NOx emission requirements of 14 ng/J or 20 PPM. 11-1/4" (285 mm) 4" (101 mm) 6-1/4" (159mm) HOT 5-1/2" (140 mm) Ultra-Low NOx Emissions 17-3/4" (450 mm) 7" (180 mm) 4" (102 mm) Female 24-7/8" (631 mm) Condensing Technology Provides 0.95 Energy Factor INDOOR MODEL 23-5/8" (600 mm) ENERGY STAR Qualified ® INDOOR MODEL 10.5 0.95 Sizing Chart COLD 5/8" (17 mm) (Number of Showers) 3/4” NPT 3/4” NPT Clearance (Inches) Cold Warm Climate*** Top Climate** Bottom Side Front Back Indoor Models ATI-540H-N Natural 2.5 4 12 12 2 4 *For propane models, change “N” to “P” in the model number (example:ATI-540H-P) For outdoor models change “I” to “O” in the model number (example: ATO-540-N). **Cold climate represents 70°F temperature rise ***Warm climate represents 50°F temperature rise 0.5 115 COMMERCIAL GAS TANKLESS HEAVY-DUTY 24-7/8" (632.9mm) 12-1/4" (311.5mm) 15" (381mm) 8" (203mm) 1/2" (11.9mm) 5" (127mm) 2-1/2" (62.1mm) ASME Models Available 25-1/4" (642mm) 5” Category III Stainless Steel Venting Vertical or Horizontal Venting Installation 28-7/8" (734mm) Commercial-Grade Copper Heat Exchanger (Non-ASME Models) 4-7/8" (122.9mm) Power Vent Design 1/2" (12.5mm) Electronic Ignition 4-3/8" (110.8mm) GAS -3/8" (137.3mm) HOT ® Low NOx Emissions 4" (100mm) 120V 1-5/8" (40mm) COLD 6-3/4" (171.3mm) 120V 7-3/8" (186mm)GAS 5-7/8" (150mm) HOT 7-5/8" (194.3mm) COLD Combined Indoor/Outdoor Models Easy-Link up to 4 Units Multi-Link up to 10 Units 10-Year Limited Warranty on Heat Exchanger / 5-Year Limited Parts Warranty Model Number** Fuel Type Gas Consumption Input Min. BTU/H Max. BTU/H Thermal Efficiency Inlet Gas Pressure Min. W. C. Max. W. C. GPM*** ATIO-910-N Natural 15,000 380,000 80% 5 10.4 ATIO-910-P Propane 15,000 380,000 82% 8 14 0.5-14.5 0.5-14.5 ATIO-910-AN* Natural 15,000 380,000 80% 5 10.4 0.5-14.5 ATIO-910-AP* Propane 15,000 380,000 82% 8 14 0.5-14.5 Dimensions in Inches Model Number** ATIO-910-N ATIO-910-P ATIO-910-AN* ATIO-910-AP* Model Number** ATIO-910-N ATIO-910-P ATIO-910-AN* ATIO-910-AP* Height Width Depth 25-1/4 25-1/4 25-1/4 25-1/4 24-7/8 24-7/8 24-7/8 24-7/8 12-1/4 12-1/4 12-1/4 12-1/4 Volt AMP 120 120 120 120 1.48 1.48 1.48 1.48 Flue Intake Hot/Cold Gas Conn. Approx. Shipping Weight (lbs) 5” O.D. 5” O.D. 5” O.D. 5” O.D. 5” O.D. 5” O.D. 5” O.D. 5” O.D. 1” NPT 1” NPT 1” NPT 1” NPT 113 113 113 113 * ASME Models **Outdoor installations require vent cap. ***Current numbers based on factory testing; 0.5 GPM required for activation; 0.4 GPM required for continuous fire after initial ignition. 116 117 COMMERCIAL ELECTRIC DEN/DEL ELECTRIC DURA-POWER™ TOP VIEW DEL 6/10/15/20 OUTLET 3/4” (FEMALE) NPT HOT WATER OUTLET DEL-6 Glasslined Tank 3/4” NPT RELIEF VALVE OPENING • Thirteen sizes, 6 thru 119 gallon capacity. Tank interior is coated with glass specially designed by A. O. Smith for water heater use. “B” ELECTRICAL CONNECTION Elements • Zinc plated copper sheaths for longer life. OUTLET 3/4” (FEMALE) OUTLET NPT 3/4” (FEMALE) NPT 3/4” NPT RELIEF VALVE OPENING “B” Standard Voltages ELECTRICAL 2 1/2” CONNECTION (63.5 mm) • 120, 277 single phase and 208, 240 and 480V unbalanced three-phase delta; easily converted to single-phase at terminal block (except 208V with 6000 watt elements). Single element heater, singlephase only. INLET JUNCTION 3/4” (FEMALE) BOX NPT “C” U. S. Gallons/Hr at Temperature Rise Indicated F° 100 /1500 GPH 6 /2000 GPH 8 /2500 GPH GPH GPH GPH GPH GPH 10 12 16 18 20 24 GPH GPH GPH GPH GPH 24 32 36 41 49 “D” “A” BRASS DRAIN VALVE JUNCTION BOX “C” TOP VIEW 2 1/2” DEN 30 - 120 (63.5 mm) “B” “A” “A” DRAIN VALVE 3 3/4” (95.25 mm) 3 3/4” (95.25 mm) FRONT VIEW DEL 30/40/50 FRONT VIEW DEN 30-120 Dimensions in Inches Model Number Gallon Capacity A B C D Non-Simultaneous Operation 3000/3000 4000/4000 4500/4500 5000/5000 6000/6000 Simultaneous Operation 3000/3000 4000/4000 4500/4500 5000/5000 6000/6000 6 gallon model not available above 3.0 kW 6/10/15/20 gallon model all A6 circuit (2 wire) only t = Non simultaneous circuit only ( ) = Simultaneous only in 3 Ph 118 INLET 3/4” (FEMALE) NPT 3/4” NPT RELIEF VALVE OPENING TOP VIEW DEL 30/40/50 3 3/4” NPT RELIEF VALVE OPENING • Factory-installed. Just bring the service to heater and connect to block. Terminal block not supplied on 120V & 277 volt models. (No junction box on DEL6-20) Element Wattage (Upper/Lower) INLET OUTLET 3/4” (FEMALE) 3/4” (FEMALE) NPT NPT “B”VIEW FRONT DEL 6/10/15/20 *(NO SIDE OUTLET AVAILABLE FOR DEL-6 MODELS) Terminal Block “A” FRONT VIEW DEL 6/10/15/20 *(NO SIDE OUTLET AVAILABLE FOR DEL-6 MODELS) ALTERNATE OUTLET 3/4” (FEMALE) NPT “D” “C” INLET 3/4” (FEMALE) NPT TOP VIEW DEL 6/10/15/20 • Medium watt density means lower surface temperature to minimize scale build-up and more surface to heat water. Element sizes from 1.5 to 6 KW. Maximum input 12 KW ALTERNATE OUTLET 3/4” (FEMALE) NPT Approx. Shipping Weight (lbs.) Compact Models DEL-6S 6 15-1/2 14-1/4 11 N/A 35 DEL-10S 10 18-1/4 18 12-1/2 N/A 54 DEL-15S 15 20 26 22-1/4 18 21-3/4 20-1/2 15-3/8 N/A N/A 58 73 30 40 50 30-7/8 32-1/4 32-1/4 21-3/4 24-1/8 24 25-9/16 26-1/2 25-1/8 8 8 8 100 125 166 30 40 50 66 80 119 34-1/2 45-1/8 54-7/8 60-3/4 59-3/8 62-7/16 20-1/2 20-1/2 20-1/2 21-3/4 24 29-3/8 8 8 8 8 8 8 98 113 131 176 211 326 DEL-20S Lowboy Models DEL-30D DEL-40D DEL-50D Tall Models DEN-30D DEN-40D DEN-52D DEN-66D DEN-80D DEN-120D N/A N/A N/A N/A N/A N/A S= Single Element D= Dual Elements Dual element models wired for 3-phase 208/240/480 volt. Field convertible to 1-phase. 119 COMMERCIAL ELECTRIC GOLD Xi SERIES WATER OUTLET Advanced Electronic Control • Plain English Text and Animated Icons Display Diagnostics C iCOMM™ Compatible and Can be Monitored from Remote Locations. Call 1.888.WATER02 for More Information. CONDUIT OPENING Economy Mode Operation - Lowers the Operating Set Point and Reduces Operating Costs Thermostatic Linear Sequencing Control Helps Reduce Current Surges and Provides Accurate Control of Water Temperature 3/4” NPT OPENING Goldenrod Elements DISPLAY FOR ELECTRONIC CONTROL MODELS ONLY • All DVE models ship standard with patented Goldenrod 24K gold plated elements. Goldenrod elements provide long life with superior scaling resistance. ASME/CRN (optional) Listed 3-Year Limited Tank and 1-Year Limited Parts Warranty A • For complete warranty information, consult written warranty or go to hotwater.com INLET OPENING DRAIN VALVE 5.25 B Model Number DVE-52* DVE-80 DVE-120 Dimensions in Inches Gallon Capacity A B C Approx. Shipping Weight (lbs) 50 80 119 55-3/4 60-1/4 62-1/4 21-3/4 25-1/2 29-1/2 27 31 35 265 280 390 *DVE-52 is maximum 36kW See specification sheets or contact your local rep for optional kW’s available 120 121 COMMERCIAL ELECTRIC GOLD SERIES WATER OUTLET Gold Elements C • DRE models ship with the Goldenrod 24K gold plated elements (see element availability chart on back). • Patented Goldenrod elements provide long life and superior scaling resistance. CONDUIT OPENING • Low watt density means lower surface temperature to minimize scale buildup and more surface to heat water. Goldenrod elements carry a one-year warranty against failure due to lime scale build-up. Fusing 3/4” NPT OPENING • Protects all elements, thermostats, and internal wiring circuits against excess current flow. Meets National Electrical Code requirements that non-ASME tanks must have internal fusing when current draw exceeds 48 amps. Available as an option on Canadian built heaters Meets the Standby Loss Requirements of the U. S. Department of Energy and Current Edition of AHRAE/IESNA 90.1. A 3-Year Limited Tank and 1-Year Limited Parts Warranty • For complete warranty information, consult written warranty or go to hotwater.com INLET OPENING DRAIN VALVE 5.25 B Model Number DRE-52 DRE-80 DRE-120 Dimensions in Inches Gallon Capacity A B C Approx. Shipping Weight (lbs) 50 80 119 55-3/4 60-1/4 62-1/4 21-3/4 25-1/2 29-1/2 27 31 35 265 280 390 * DRE-52 is maximum 36kW See specification sheets or contact your local rep for optional kW’s available 122 123 COMMERCIAL ELECTRIC HEAVY-DUTY CUSTOM Xi Advanced Electronic Control • Provides Precise Temperature Control and Plain English Text with Animated Icons Display iCOMM™ Compatible and Can be Monitored from Remote Locations. Call 1.888.WATER02 for More Information. Low-Water Cutoff—Remote Electronic Immersion-Type Probe to Prevent Energizing of the Elements, Eliminating Accidental Dry Firing Incoloy-Sheath Heating Elements Standard Factory-Wired, 120V Circuit Controls Power-Circuit Fusing for System Protection Glass-Lined Tank, with ASME Construction SA Certified and ASME Rated T&P C Relief Valve BACnet and Modbus Compatible with ICC Interface 3-Year Limited Tank and 1-Year Limited Parts Warranty • For complete warranty information, consult written warranty or go to hotwater.com Dimensions in Inches Model Gallon Maximum Number Capacity kW Input A B C D 5 10 20 30 40 50 65 80 100 120 20-1/4 26-1/4 27-1/4 35-3/4 45-3/4 54-3/4 50-1/2 49-1/4 58-1/4 63-1/4 16-1/4 18-3/4 20-1/2 20-1/2 20-1/2 20-1/2 26-1/2 28 28 30 22-1/2 25 26-1/2 26-1/2 26-1/2 26-1/2 33-1/2 35 35 37 5-1/4 5-1/4 5-3/4 5-3/4 5-3/4 5-3/4 7 7 7 7-1/2 DSE-5 DSE-10 DSE-20 DSE-30 DSE-40 DSE-50 DSE-65 DSE-80 DSE-100 DSE-120 124 3 6 18 24 36 90 90 90 90 90 Approx. Shipping Weight (lbs) 82 106 130 150 190 221 267 285 354 420 125 COMMERCIAL ELECTRIC SU MODELS HEAVY-DUTY CMC/SU BOOSTER ELECTRIC DURA-POWER™ CMC MODELS Incoloy-Sheath Heating Elements Standard A. O. Smith Goldenrod® Elements Optional Standard Voltages for Easy Installation Immersion Thermostat for Efficient Control Power-Circuit Fusing for System Protection Heavy-Duty Magnetic Contactors Factory-Wired 120V Circuit Controls Dimensions in Inches C Inlet/ Outlet Approx. Shipping Weight (lbs) 13 23.5 3/4 80 12 18 23.5 3/4 96 25 22.25 23 3/4 200 Gallon Capacity A B CMC-6 through CMC-18 5 13.75 CMC-20 through CMC-54 5 SU-6 through SU-54 20 Model Number 3-Year Limited Warranty SU MODELS *CMC-6 and SU-54 have three dimension heaters. 126 127 COMMERCIAL ELECTRIC AIR-TO-WATER ELECTRIC HEAT-PUMPS Air-to-water heat pump water heaters remove unwanted heat and humidity from the surrounding air and use it to heat water. The refrigeration-based system produces cool, dehumidified air for spot cooling or to reduce the load on air conditioning systems. High Efficiency Water Heating “Environmentally-Friendly” Green Technology uses Non-Ozone Depleting R-134a Refrigerant Model Number Simplified Installation Efficient Scroll Compressor Sanitary Hot Water for Commercial or Industrial use Coefficient Performance (COP) Between 3.9 and 4.2 for Water Heating Standard 208/230 VAC, Tri-Phase Power (Optional 460 VAC, Triphase) Maximum 140°F Final Tank Temperature at Common Indoor Temps Accessories Include: • Digital temp controller with tank probe AWH-35 AWH-55 AWH-75 AWH-100 AWH-115 AWH-140 AWH-170 Water Heating Capacity Dimensions in Inches Btu/hr* Inlet/ Outlet Water A B C Approx. Shipping Weight (lbs) 35,500 58,000 76,000 98,000 113,000 142,000 171,000 1 1 1.5 1.5 1.5 2 2 40 47 57 63 63 63 75 26 32 32 38 38 38 46 24.75 28.50 28.50 42.50 42.50 42.50 42.50 315 405 485 660 665 725 880 *Performance rating at 75º F, 55% Relative Humidity and 100ºF incoming water temperature **Blower design at 0.35” external static pressure C.O.P. coefficient of performance All models standard 208/230V, Tri-phase, 60 Hz. Optional 460v Tri-phase 60Hz Optional 240v Single Phase 60Hz (available on AHW-35 and AHW-55 only) • Metal mesh cleanable filter • Corrosive duty package; 316 stainless steel cabinet, polyurethane coated evaporator coil and blower housing. Recommended for coastal areas. 5-Year Compressor Limited Warranty/1-Year Parts Limited Warranty • For complete warranty information, consult written warranty or go to hotwater.com 128 129 COMMERCIAL ELECTRIC HEAVY-DUTY PREMIUM ELECTRIC DVE/DHE DURA-POWER™ Advanced Electronic Control A. O. Smith’s New Propriety Electronic Water Heater Control, Provides Precise + or - 1ºF Temperature Control, that is Ideal for Industrial and Food Service Applications where Exact Temperatures of Hot Water are Needed. iCOMM™ Compatible and Can be Monitored from Remote Locations. Call 1.888.WATER02 for More Information. Recovery Standard Number of Capacity BTU Input kW Immersion GPH @ and Output Ratings Heaters 100°F Rise Recovery Standard Number of BTU Capacity kW Immersion Input and GPH @ Ratings Heaters Output 100°F Rise Solid State Step Control XI On/Off 180 12-15kW 614,340 738 15 210 14-15kW 716,730 861 XI Progressive 240 16-15kW 819,120 987 24 2-12kW 81,912 98 270 18-15kW 921,510 1,107 30 2-15kW 102,390 123 300 20-15kW 1,023,900 1,230 36 3-12kW 122,868 147 330 22-15kW 1,126,290 1,353 45 3-15kW 153,585 184 360 24-15kW 1,228,680 1,476 60 4-15kW 204,720 246 390 26-15kW 1,331,070 1,599 75 5-15kW 255,975 307 420 28-15kW 1,433,460 1,722 90 6-15kW 307,170 369 105 7-15kW 358,365 430 120 8-15kW 409,560 492 150 10-15kW 511,950 615 450 30-15kW 1,535,850 1,845 480 32-15kW 1,638,240 1,968 510 34-15kW 1,740,630 2,091 540 36-15kW 1,843,020 2,214 570 38-15kW 1,945,410 2,337 600 40-15kW 2,047,800 2,460 630 42-15kW 2,150,190 2,583 660 44-15kW 2,252,580 2,706 690 46-15kW 2,345,970 2,829 720 48-15kW 2,457,360 2,952 810 54-15kW 2,764,530 3,321 900 60-15kW 3,071,700 3,690 Heavy-Duty Magnetic Contactors 990 66-15kW 3,378,870 4,059 1080 72-15kW 3,686,040 4,428 Factory-wired, 120V Circuit Controls 1170 78-15kW 3,993,210 4,797 1260 84-15kW 4,300,380 5,166 1350 90-15kW 4,607,550 5,535 Low-Water Cutoff 1440 96-15kW 4,914,720 5,904 1530 102-15kW 5,221,890 6,273 Glass-Lined Tank (Standard) 1620 108-15kW 5,529,060 6,642 1800 120-15kW 6,141,600 7,380 1980 132-15kW 6,757,740 8,118 2040 136-15kW 6,962,520 8,364 2220 148-15kW 7,576,860 9,102 2250 150-15kW 7,679,250 9,225 2400 160-15kW 8,188,800 9,840 2540 176-15kW 9,010,320 10,824 2820 188-15kW 9,624,660 11,562 3000 200-15kW 10,236,000 12,300 Progressive Modulating- Sizes the Input of Available Elements to Match Current Load Conditions. Rotates and Lead Lags Element Loads to Provide Long Life and Equal Wear. Heavy-Duty Incoloy-Sheath Heating Elements 240V, 480V and 600V Factory-Installed Terminal Block Power-Circuit Fusing Handhole Clean-Out(s) Color-Coded Circuitry CSA Certified and ASME Rated T&P Relief Valve 1-15kW 51,195 61 Complete model number includes the desired kw at the end, minimum installation Clearances required: 30˝ from front, 12˝ from top and 24˝ from right side BACnet and Modbus connectivity available with the ICC Gateway device on models with 150 kW or less 130 131 COMMERCIAL ELECTRIC HEAVY-DUTY PREMIUM ELECTRIC DVE/DHE DURA-POWER™ (CONTINUED) Model Number Nominal Gallon Capacity Dimensions in Inches A B C D E 77 91 81 93 100 94 109 121 111 111 138 150 177 211 296 317 345 36 36 42 42 42 48 48 48 54 60 60 60 66 72 78 90 102 10-1/2 17-1/2 10-1/2 24 8-1/4 17 8-1/4 23 8-1/4 26-1/2 14 24 14 32 14 38 16-1/2 32 16-1/2 29-1/2 16-1/2 43 16-1/2 50 20 60 20 72-1/2 20-1/2 113-1/2 20-1/2 121 22 132 30 30 36 36 36 42 42 42 48 48 48 56 60 60 60 66 72 78 90 102 37 37 43 43 43 49 49 49 55 55 55 61 67 67 67 73 79 85 97 109 16 16 17-1/2 17-1/2 17-1/2 19 19 19 21 21 21 23 24-1/2 24-1/2 24-1/2 25 27-1/2 30 30 30 F Horizontal Electric Storage Heater DHE-200 DHE-250 DHE-300 DHE-350 DHE-400 DHE-500 DHE-600 DHE-700 DHE-800 DHE-1,000 DHE-1,250 DHE-1,500 DHE-2,000 DHE-3,000 DHE-5,000 DHE-7,500 DHE-10,000 200 250 300 350 400 500 600 700 800 1,000 1,250 1,500 2,000 3,000 5,000 7,500 10,000 38-1/2 38-1/2 44-1/2 44-1/2 44-1/2 51 51 51 57 61 61 61 70 76 82 94 106 31 48 36 48 55 48 64 76 64 59 86 98 120 131 195 218 220 Vertical Electric Storage Heater DVE-140 DVE-150 DVE-150L DVE-200 DVE-250 DVE-300 DVE-350 DVE-400 DVE-500 DVE-600 DVE-700 DVE-800 DVE-1000 DVE-1250 DVE-1500 DVE-2000 DVE-3000 DVE-5000 DVE-7500 DVE-10,000 132 140 150 150 200 250 300 350 400 500 600 700 800 1,000 1,250 1,500 2,000 3,000 5,000 7,500 10,000 83-1/2 83-1/2 59-1/2 79-1/2 93 83-1/2 95-1/2 102-1/2 97 112 124 116 116 143 155 183 217 309 330 358 6 6 6 6 6 6 6 6 6 6 6 8 10 10 10 12 14 14 14 14 17 17 21 21 21 25-1/2 25-1/2 25-1/2 30 30 30 34 38 38 38 42-1/2 47 51 59-1/2 68 Complete model number includes the desired kW at the end (example: DVE-140-120) Minimum installation clearances required: 30˝ from front, 12˝ from top and 24˝ from right side 150 gallon available in both tall (T) and short (S) models BACnet and Modbus connectivity available with the ICC Gateway device on models with 150 kW or less 133 COMMERCIAL XP DOMESTIC WATER HEATERS Up to 99% in Low Temperature Applications Super Alloy Metal Fiber Burners 20:1 Turndown Models 2 Million BTUH and up, 10:1 Turndown Models 1.7 Million BTUH and Down Recovery Capacities ASME Rated Relief Valve 160 lb. ASME Working Pressure Factory-Installed Bronze Circulating Pump Adjustable Pump Delay Honeywell Sola Control with Color Touch Screen LCD Display Multi-Burner Sequencing Models 2 Million BTUH and up Have 4 Burners; Models 1.7 Million BTUH and Down Have 2 Burners Redundant Flow and Low Water Protection-Factory Installed LWCO and Flow Switch(s) ® Manual Reset High Limit CRN 316L Stainless steel Heat Exchanger(s) Professional Start-Up Included Required for Activating Warranty and Assuring Maximum Operating Performance Meets the requirements of South Coast Air Quality Management District in Southern California and the requirements of Texas Commission on Environmental Qualities. 5-year Heat Exchanger and 1-Year Parts Limited Warranty Model Number XWH-1000 XWH-1300 XWH-1700 XWH-2000 XWH-2600 XWH-3400 BTU/HR Natural Gas Input Water Flow 920,000 1,300,000 1,700,000 2,000,000 2,600,000 3,400,000 GPH GPH GPH GPH GPH GPH Temperature Rise °F 100 1,065 1,497 1,962 2,317 3,000 3,956 Simple Heat Exchanger Model Dimensions Models XWH-1000 XWH-1300 XWH-1700 Dimensions in Inches Flue Outlet Diameter 6 8 8 Air Intake Diameter 6 6 8 49 68 29 38 23 9 34 45 6 11 11 2-1/2 inch NPT 2-1/2 inch NPT 2 inch NPT 57 76 29 37 24 9 34 45 6 11 12 2 inch NPT 2 inch NPT 2 inch NPT Wat Inlet Water Outlet Gas Inlet A B C D E F G H J K L 47 67 29 37 23 9 34 44 6 11 12 • For complete warranty information consult written warranty or go to hotwater.com 134 135 COMMERCIAL XP DOMESTIC WATER HEATERS (CONTINUED) Recovery Capacities Model Number BTU/HR Natural Gas Input Recovery Capacity GPH @ 100°F Rise Approx. Shipping Weight (lbs) 920,000 1,300,000 1,700,000 2,000,000 2,600,000 3,400,000 1,065 1,497 1,962 2,317 3,000 3,956 865 1065 1140 1485 1830 2175 XWH-1000 XWH-1300 XWH-1700 XWH-2000 XWH-2600 XWH-3400 Double Heat Exchanger Model Dimensions Models XWH-2000 XWH-3400 Flue Outlet Diameter 8 8 10 Air Intake Diameter 8 8 10 49 80 37 22 41 6 10 4 19 12 4 inch NPT 4 inch NPT 3 inch NPT 57 91 37 22 41 6 10 4 19 13 3 inch NPT 3 inch NPT 2 inch NPT Wat Inlet Water Outlet Gas Inlet A B C D E F G H J K 136 XWH-2600 Dimensions in Inches 47 78 36 22 40 7 10 4 20 12 137 COMMERCIAL WATER HEATER BURKAY® GENESIS® DOMESTIC WATER HEATER B F AIR INLET GAS CO NN ECTION G F EXHAUST VENT EXHAUST VENT G GAS CO NN ECTION INLET INLET OUTLET 85% Thermal Efficiency OUTLET A Stage Gas Firing System - Prevents Short Cycling and Ensures Smooth Operation, Saves Fuel and Extends Product Life H H E lectronic Control with Precise Temperature Management E E C D DR AIN DR AIN J SIDE VIEW J K K L L GWH-400 THRU GWH-750 GWH-1000 THRU GWH-2100 Low NOx Operation F AIR INLET B GAS CO NN ECTION G INLET Copper Finned-Tube Heat Exchanger OUTLET Space-Saving Design-Optional Stack Rack Allows One Unit to be Stacked on Top of Another, Doubling Output within the Footprint of a Single Unit ® SIDE VIEW A E C Meets ASHRAE/IESNA 90.1-2004 D DR AIN K L Multiple Venting Options Factory Start-up Included 5-Year Heat Exchanger and 1-Year Parts Limited Warranty • For complete warranty information, consult written warranty or go to hotwater.com. Model Number GWH-400N GWH-500N GWH-650N GWH-750N GWH-1000N GWH-1250N Model Number GWH-400N GWH-500N GWH-650N GWH-750N GWH-1000N GWH-1250N GWH-1450N GWH-1800N GWH-2100N Input MBH Recovery Capacity GPH @ 100°F Rise Approx. Shipping Weight (lbs) 399 500 650 750 990 1,260 1,440 1,800 2,070 412 515 670 773 1,020 1,298 1,484 1,855 2,133 454 467 551 611 843 939 1,035 1,168 1,285 When ordering propane change “N” to “P” in the model number (example GWH-750P) J SIDE VIEW GWH-1450N GWH-1800N GWH-2100N Model Number GWH-400N GWH-500N GWH-650N GWH-750N GWH-1000N GWH-1250N GWH-1450N GWH-1800N GWH-2100N GWH-400 THRU GWH Dimensions in Inches A B C D E F 31-1/2 31-1/2 31-1/2 31-1/2 36 36 36 36 36 7 7 8-1/2 8-1/2 8-3/4 9-3/4 10-1/2 11 11 37-5/8 45-3/8 56-3/4 64 48-1/2 58-3/4 68-7/8 82-3/8 92-5/8 8-7/8 8-7/8 8-7/8 8-7/8 5-7/8 5-7/8 5-7/8 5-7/8 5-7/8 12-1/2 12-1/2 12-1/2 12-1/2 15-7/8 15-7/8 15-7/8 15-7/8 15-7/8 7 7 8-1/2 8-1/2 22-1/2 22-1/2 22-1/2 22-1/2 22-1/2 Dimensions in Inches G H J K L 3-1/4 3-1/4 3-1/4 3-1/4 8-1/2 9-3/4 10-1/4 10-7/8 10-7/8 29-3/4 29-3/4 29-3/4 29-3/4 33-3/4 33-3/4 33-3/4 33-3/4 33-3/4 6-3/8 6-3/8 6-3/8 6-3/8 8-3/4 8-3/4 8-3/4 8-3/4 8-3/4 12-5/8 12-5/8 12-5/8 12-5/8 19-7/8 19-7/8 19-7/8 19-7/8 19-7/8 22-1/4 22-1/4 22-1/4 22-1/4 33 33 33 33 33 When ordering propane change “N” to “P” in the model number (example GWH-750P) 138 139 COMMERCIAL WATER HEATER VARIABLE FIRE™ HIGH-EFFICIENCY WATER HEATERS FF FF GAS GAS CO CONN NNECTION ECTION GG GAS GAS CO CONN NNECTION ECTION AIR AIR INLET INLET GG AIR AIR INLET INLET INLET INLET Up to 87% Thermal Efficiency HH HH INLET INLET OUTLET OUTLET OUTLET OUTLET Advanced Modulating Control with Venturi-Mixing Gas/Air Ratio System AA EXHAUST EXHAUST VENT VENT EE EE Small Footprints, Zero Clearance to Combustibles on Sides of Unit Category II and IV listed - Requires the use of AL29-4C a vent material that resists the effects of corrosive condensates JJ BB SIDE SIDEVIEW VIEW Complies with SCAQMD Rule 1146.2 and Other Air Quality Management Districts with Similar Requirements for Low NOx emissions D1 D1 D2 D2 PP PP • For complete warranty information, consult written warranty or go to hotwater.com. F VWH1500N VWH2000N H OU 140 EXH VEN A E K J B L DR AINS (3/4 " NPT) C M N D1 D2 SIDE VIEW P REAR VIEW REAR VIEW (VWH0500N-VWH1000N) *Pump shipped loose Model Number Dimensions in Inches A B VWH0500N 44-1/2 30-3/8 VWH0750N 52-1/8 30-3/8 VWH1000N 59-1/4 30-3/8 BTU/Hr Input Recovery Capacity GPH @ 100°F Rise Approx. Shipping Weight (lbs) Model Number 500,000 750,000 999,999 1,500,000 2,000,000 527 791 1054 1582 2109 573 622 662 1,118 1,187 VWH0500N Change “N” to “P” when ordering propane (LP) gas (Example: VWH-750-P). AIR INL G INLET VWH2000N 76-5/8 31-5/8 VWH1000N REAR REARVIEW VIEW (VWH1500N-VWH2000N) (VWH1500N-VWH2000N) GAS CO NN ECTION VWH1500N 65-3/8 31-5/8 VWH0750N REAR REARVIEW VIEW REAR REARVIEW VIEW REAR REAR VIEW VIEW (VWH0500N-VWH1000N) (VWH0500N-VWH1000N) *Pump *Pumpshipped shippedloose loose EXHAUST EXHAUST VENT VENT LL MM NN Professional Start-Up Included - Required for Activating Warranty and Assuring Maximum Operating Performance 5-Year Heat Exchanger and 1-Year Parts Limited Warranty VWH0500N DR DRAINS AINS (3/4" (3/4"NPT) NPT) MM NN Meets Thermal Efficiency and Standby Loss Requirements of the U.S. Department of Energy and Current Edition of ASHRAE/ IESNA 90.1 Model Number JJ LL DR DRAINS AINS (3/4 (3/4""NPT) NPT) CC Capable of Firing from 100% to 25% (or a 4:1 Turndown Ratio) of the Rated Input, Based on the Current System Demand ® KK KK VWH0750N VWH1000N VWH1500N VWH2000N C D1 D2 E F G 6 6 6 8 8 12-1/2 12-1/2 12-1/2 16-1/2 16-1/2 15-1/8 15-1/8 15-1/8 19-3/8 19-3/8 34-1/8 41-3/4 48-7/8 58-3/4 70 19-5/8 19-5/8 19-5/8 21-1/8 21-1/8 7-3/4 7-3/4 7-3/4 9-1/2 9-1/2 Dimensions in Inches H J K L M N P 7-3/8 7-3/8 7-3/8 9-1/2 9-1/2 11-3/8 11-3/8 11-3/8 22 27-3/8 23 30-1/2 37-5/8 43-1/4 54-3/8 6-1/2 6-1/2 6-1/2 5-3/4 5-3/4 11-1/2 11-1/2 11-1/2 13-1/2 13-1/2 17-1/2 17-1/2 17-1/2 21-3/8 21-3/8 23-1/8 23-1/8 23-1/8 27-1/8 27-1/8 Authorized start-up service included-required to activate warranty. Consult your local factory representative (Continental U.S. Only). Change “N” to “P” when ordering propane (LP) gas (Example: VWH-750-P). 141 COMMERCIAL WATER HEATER BURKAY® ENERGY SAVER COPPER HEAT EXCHANGER H L WATER OUTLET All Non-Ferrous Waterways • Rustproof because water comes in contact with nothing but copper, brass or bronze A • Copper transfers heat eight times faster than ferrous metals yet offer remarkable structural strength without excessive weight • Free from the effects of thermal shock C Efficiency Copper Coil Combustion Chamber • Continuous coils of tightly wound copper tubing form a unique combustion chamber B D M WATER INLET F E W • Water circulating thru the coils, around the flame, captures radiant heat which may otherwise be lost J High Efficiency Stainless Steel Burner • Developed especially for A. O. Smith water heaters using the very latest burner principles G Forced Water Cirrculation Improves System Efficiency K • Water moving at 2 to 4 feet per second helps to prevent lime buildup and also scrubs extra heat from the copper coil combustion chamber M WATER INLET Model Input Rating BTU/Hr. Natural & Propane Gas Temperature Rise-100°F Gallons Per Hour Models HWH-120 A 49-3/8 30-3/8 23-5/8 20-3/4 5-1/2 10 11-13/16 6 26-11/16 20-3/4 1-1/4 NPT 1 NPT 1/2 NPT 1-3/4 120 lbs. 160,000 154 HW-200M 199,000 195 C 217 D 225,000 Nat. Gas Only B E F G H J K L M N W Approx. Shipping Weight 142 HWH-160 HWH-200 HWH-225 50-1/8 30-3/8 23-5/8 20-3/4 5-1/2 10 11-13/16 7 26-11/16 20-3/4 1-1/4 NPT 1 NPT 1/2 NPT 1-3/4 53-1/4 33-1/8 27-1/8 20-3/4 5-1/2 10 11-13/16 7 26-11/16 20-3/4 1-1/4 NPT 1 NPT 1/2 NPT 1-3/4 60 33-1/8 27-1/8 20-3/4 5-1/2 10 11-13/16 7 26-11/16 20-3/4 1-1/4 NPT 1 NPT 1/2 NPT 1-3/4 155 lbs. 165 lbs. 175 lbs. Dimensions in Inches HW-160M HW-225M N GAS L INLET WATER OUTLET 143 E HOT WATER SUPPLY BOILERS BURKAY® HW GAS DOMESTIC WATER HEATERS & BOILERS F EXTRA OPENING FOR THERMOMETER AND PRESSURE RELIEF VALVE HW-520 AND H HW-670 HW-300 All Non-Ferrous Waterways • All water tubes are made from copper • Brazed joints or flare union construction make the boiler immune to the effects of thermal shock and thermal cycling L INLET NPT E • The combustion chamber is a heat exchanger formed from a two passage coil of tightly wound continuous copper tube G J EXTRA OPENING FOR THERMOMETER AND PRESSURE Dimensions in Inches T RELIEF VALVE HW-520 AND H HW-670 A B ® Models HW-300 HW-399 HW-420 HW-520 65 57-1/8 57-1/8 68-5/16 68-5/16 45-1/8 45-1/8 56-1/4 56-1/4 38-3/4 38-3/4 46 46 Overall height S Height to Top of Jacket P 43-1/4 HW-300 HW-399 HW-420 HW-520 HW-670 Nat. HW-670 Prop 144 Recovery Capacity GPH @ 100°F Rise Approx. Shipping Weight (lbs) 300,000 399,000 420,000 520,000 660,000 670,000 298 392 417 516 656 656 255 301 301 381 381 381 HW-670 K C Floor to Center Line Water Outlet D Diameter of Jacket OF 25-1/4 LOCATION MANUAL 27 27 27 27 E Floor to Center OUTSIDE JACKET WHEN 12 12 Line WaterCODE Inlet REQUIRE (NOT SUPPLIED) 12 12 12 36 MAIN SHUTOFF VALVE Input Rating BTU/HR Natural & Propane (LP) Gas LOCATION OF MANUAL MAIN SHUTOFF VALVE OUTSIDE JACKET WHEN CODE REQUIRE (NOT SUPPLIED) B N GAS INLET (MALE) NPT Efficiency Copper Coil Combustion Chamber • A wrap of insulation on the outside of the coil retains the heat captured by the circulating water K A D C • Water circulating through this coil surrounds the main burner and captures the radiant heat S M OUTLET NPT • A great boiler for domestic hot water supply T P F • All castings are made of bronze or brass Model Number G J F Draft Diverter Outlet Diameter 8 10 10 10 12 G Floor to Center Line Gas Inlet 16-1/2 16-3/4 16-3/4 8 8 29-5/8 9 31-1/2 9 31-1/2 9 36-1/2 9 36-1/2 9 H Overall Depth J Support Height K Width of Control String (approx.) 14 14 14 11 11 L Pipe Size of Water Inlet (NPT) 1-1/4 1-1/2 1-1/2 2 2 M Pipe Size of Water Outlet (NPT) 1-1/4 1-1/2 1-1/2 2 2 N Pipe Size of Gas Inlet (NPT) 3/4 3/4 1 1 1 P Control String Plus 1/2 Jacket Diameter (approx.) 26-5/8 27-1/2 27-1/2 24-1/2 24-1/2 S Horizontal Length between Water Inlet & Outlet 5-3/8 5-1/2 5-1/2 5-3/4 5-3/4 T Control String from Jacket 5 5 5 7 7 145 COMMERCIAL ELECTRIC BOILERS DURA-POWER™ NW ELECTRIC BOILERS UL MINIMUM CLEARANCE REQUIRMENTS: 24” ALL SIDES, 12” TOP NOTE: ALLOW 30” CLEARANCE FOR HINGED CONTROL COMPARTMENT DOORS. ELEMENTS CAN BE CHANGED WITH 24” CLEARANCE. AN ADDITIONAL CONTROL PANEL IS REQUIRED ON UNITS ABOVE 500kW RATED AT 208 OR 240 VOLTS. MODELS: NW-37, NW-60, NW-96 AND NW-150 ASME Code Construction Incoloy Immersion Heaters Control and Power Circuit Fusing Pilot Switch and Light Heavy-Duty UL-Rated Magnetic Contactors Rated for 100,000 Low-Water Cutoff 120V Control Circuit Modulating Step Control 1-Year Limited Tank Warranty • For complete warranty information, consult written warranty or go to hotwater.com. Model Number NW-37 NW-60 NW-96 NW-150 NW-220 NW-334 NW-400 NW-500 NW-570 Nominal Maximum Gallon kW Input Capacity 37 60 96 150 220 334 400 500 670 180 300 480 720 1140 1740 2100 2580 3300 Dimensions in Inches A** B C D E F 42 57 69-1/2 69-1/2 71 99 90-1/2 90-1/2 96-1/2 32 32 36 54 60 60 66 72 78 30 30 38 44 50 50 56 62 68 12-1/2 12-1/2 17 20 21 25 25-1/2 26-1/2 30-1/2 12 12 16 19 25 25 28 31 34 20 20 24 27 30 30 33 36 39 G H 4 4 5 17 5-1/2 20 5-1/2 25-1/2 7-1/4 25-1/2 7-3/4 30 7-3/4 34 7-3/4 38 See heater specification sheet for additional features and options. More information on the following page. 146 147 COMMERCIAL ELECTRIC BOILERS DURA-POWER™ NW ELECTRIC BOILERS (CONTINUED) NW-37-60-K NW-37-75-K NW-37-90-K NW-37-105-K NW-37-120-K NW-37-150-K NW-37-180-K NW-60-210-K NW-60-240-K NW-60-270-K NW-60-300-K NW-96-330-K NW-96-360-K NW-96-390-K NW-96-420-K NW-96-450-K NW-96-480-K NW-150-540-K NW-150-600-K NW-150-660-K NW-150-720-K NW-220-780-K NW-220-840-K NW-220-900-K NW-220-960-K NW-220-1020-K NW-220-1080-K NW-220-1140-K NW-334-1200-K NW-334-1260-K NW-334-1380-K NW-334-1500-K NW-334-1620-K NW-334-1740-K NW-400-1800-K NW-400-1860-K NW-400-1980-K NW-400-2100-K NW-500-2220-K NW-500-2340-K NW-500-2460-K NW-500-2580-K NW-670-2700-K NW-670-2820-K NW-670-2940-K NW-670-3060-K NW-670-3180-K NW-670-3300-K 148 Standard Wattage kW 37 37 37 37 37 37 37 37 60 60 60 60 96 96 96 96 96 96 150 150 150 150 220 220 220 220 220 220 220 334 334 334 334 334 334 400 400 400 400 500 500 500 500 670 670 670 670 670 670 45 60 75 90 105 120 150 180 210 240 270 300 330 360 390 420 450 480 540 600 660 720 780 840 900 960 1,020 1,080 1,140 1,200 1,260 1,380 1,500 1,620 1,740 1,800 1,860 1,980 2,100 2220 2340 2460 2580 2700 2820 2940 3060 3180 3300 Recovery BTU Output Capacity GPH @ 100°F Rise 153,585 204,720 255,975 307,170 358,365 409,560 511,950 614,340 716,730 819,120 921,510 1,023,900 1,126,290 1,228,680 1,331,070 1,433,460 1,535,850 1,638,240 1,843,020 2,047,800 2,252,580 2,457,360 2,662,140 2,866,920 3,071,700 3,276,480 3,481,260 3,636,040 3,890,820 4,095,600 4,300,380 4,709,940 5,119,500 5,529,060 5,938,630 6,143,400 6,348,180 6,757,740 7,167,300 7,576,860 7,986,420 8,395,980 8,805,540 9,315,100 9,624,660 10,034,220 10,443,780 10,853,340 11,262,900 180 240 300 369 430 492 615 736 861 984 1,107 1,230 1,353 1,476 1,599 1,722 1,845 1,968 2,214 2,460 2,706 2,952 3,198 3,444 3,690 3,936 4,182 4,428 4,674 4,920 5,166 5,658 6,150 6,642 7,134 7,380 7,626 8,118 8,610 9,102 9,594 10,080 10,578 11,070 11,562 12,054 12,546 13,038 13,530 Number of Immersion Heaters 3 4 5 6 7 8 10 12 14 16 18 20 22 24 26 28 30 32 36 40 44 48 52 56 60 64 68 72 76 80 84 92 100 108 116 120 124 132 140 148 156 164 172 180 188 196 204 212 220 Model Number Steps Standard Number and (Standard) kW of Steps NW-37-45-K NW-37-60-K NW-37-75-K NW-37-90-K NW-37-105-K NW-37-120-K NW-37-150-K NW-37-180-K NW-60-210-K NW-60-240-K NW-60-270-K NW-60-300-K NW-96-330-K NW-96-360-K NW-96-390-K NW-96-420-K NW-96-450-K NW-96-480-K NW-150-540-K NW-150-600-K NW-150-660-K NW-150-720-K NW-220-780-K NW-220-840-K NW-220-900-K NW-220-960-K NW-220-1020-K NW-220-1080-K NW-220-1140-K NW-334-1200-K NW-334-1260-K NW-334-1380-K NW-334-1500-K NW-334-1620-K NW-334-1740-K NW-400-1800-K NW-400-1860-K NW-400-1980-K NW-400-2100-K NW-500-2220-K NW-500-2340-K NW-500-2460-K NW-500-2580-K 1 1 1 3 4 4 5 5 5 5 5 5 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 15 15 15 15 15 15 15 18 18 18 NW-670-2700-K 19 NW-670-2820-K NW-670-2940-K NW-670-3060-K NW-670-3180-K 18 18 18 18 NW-670-3300-K 18 1 @ 45 1@ 60 1 @ 75 3 @ 30 3 @ 30 +1 @15 4 @ 30 5 @ 30 4 @ 30 + 1@ 60 3 @ 30 + 2 @ 60 2 @ 30 + 3 @ 60 1 @ 30 + 4 @ 60 5 @ 60 9 @ 30 + 1 @ 60 8 @ 30 + 2 @ 60 7 @ 30 +3 @60 6 @ 30 + 4 @ 60 5 @ 30 + 5 @ 60 4 @ 30 + 6 @ 60 2 @ 30 + 8 @ 60 10 @ 60 8 @ 60 + 2 @ 90 6 @ 60 + 4 @90 4 @ 60 + 6 @ 90 9 @ 90 + 1 @ 30 10 @ 90 8 @ 90 + 2 @ 120 6 @ 90 + 4 @ 120 4 @ 90 + 6 @ 120 2 @ 90 + 8 @ 120 10 @ 120 8 @ 120 + 2 @ 150 4 @ 120 + 6 @ 150 10 @ 150 6 @ 90 + 9 @120 2 @ 90 + 13 @ 150 15 @ 120 13 @ 120 + 2 @ 150 9 @ 120 + 6 @ 150 5 @ 120 + 10 @ 150 1 @ 120 + 14 @ 150 18 @ 120 + 2 @ 90 18 @ 120 + 2 @ 150 14 @ 120 + 6 @ 150 10 @ 120 + 10 @ 150 6 @ 120 + 14 @ 150 2 @ 120 + 18 @ 150 18 @ 150 + 2 @ 180 14 @ 150 + 6 @ 180 10 @ 150 + 10 @ 180 208V Amperage 3 Phase 240V 480V 575V 128 171 213 250 292 334 417 500 584 668 751 834 917 1001 1084 1168 1251 1334 150 1668 108 144 180 217 253 289 361 433 505 577 650 722 794 866 938 1010 1083 1155 1299 1443 NOT RECOMMENDED NW-37-45-K Gallon Capacity NOT RECOMMENDED Model Number 55 73 90 108 126 144 180 216 252 288 324 360 396 432 468 504 540 576 648 720 792 864 936 1008 1080 1152 1224 1296 1368 1440 1512 1656 1800 1944 2068 2160 2232 2376 2520 2664 2808 2952 3096 45 60 75 90 105 121 151 181 211 241 271 301 331 362 392 422 452 487 542 602 663 723 783 843 904 964 1024 1084 1145 1205 1265 1386 1506 1627 1747 1807 1868 1988 2109 2229 2350 2470 2590 3240 2711 3384 3528 3672 3816 2832 2952 3073 3193 3960 3313 149 HOT WATER GENERATOR STEAM OR BOILER HOT WATER HWG GENERATOR SYSTEMS All HWG Systems are Fiberglass Insulated and Jacketed Integral Bronze Circulator Pump oth Steam and Boiler Water Units B are Custom Built to Meet Your Specifications and are Completely Assembled with Components Sized, Piped, and Checked Before Shipping ASME Rated Cathodic Protection Custom Sizes Available up to 12,000 Gallons Available in Vertical or Horizontal Models 5 -Year Limited Tank Warranty and 1-Year Limited Coil Warranty OPTIONAL Table HWG-2 • For complete warranty information, consult written warranty or go to hotwater.com. Gals./Hr Recovery (Based on Circulating Tank) Steam Press in Coil (PSIG) 180°F Boiler Water Minimum GPM Required 212°F Boiler Water Minimum GPM Required Dimensions in Inches Coil Sizes (Diameter - Length) Model Gal A B C D E HWG48-1000V 140 200 350 400 500 750 1000 89 85 102 107 86 118 150 30 36 42 42 54 54 54 22 24 25-1/2 25-1/2 30 30 30 11-1/4 15-1/2 19 19 25-1/2 25-1/2 25-1/2 2-1/2 2-1/2 2-1/2 2-1/2 3 3 3 Model Gal A B C D E F 200 350 400 500 750 1000 77 93 99 79 111 143 41 47 47 59 59 59 16 16 17 23 23 23 26 30 30 42 42 42 2-1/2 2-1/2 2-1/2 3 3 3 36 42 42 54 54 54 4-18 4-36 6-24 6-36 6-54 HWG24-140V 45 4 69 6 87 7 135 12 149 13 230 20 223 19 346 29 335 28 518 43 HWG30-200V HWG36-350V HWG36-400V HWG48-500V HWG48-750V Table HWG-2 Gals./Hr Recovery (Based on Circulating Tank) Steam Press in Coil (PSIG) 8-42 180°F Boiler Water Minimum GPM Required 212°F Boiler Water Minimum GPM Required Coil Sizes (Diameter - Length) 8-60 10-42 10-48 12-36 12-48 14-42 502 707 949 1079 1135 1544 1823 42 59 79 90 95 129 152 778 1094 1469 1670 1757 2390 2822 65 91 122 140 146 200 235 Dimensions in Inches HWG30-200H HWG36-350H HWG36-400H HWG48-500H HWG48-750H HWG48-1000H 150 151 COMMERCIAL STORAGE TANKS STANDARD JACKETED STORAGE TANKS TJ-80A TJ-80A 3/4" NPT (ANODE ) 3/4" NPT (ANODE ) 1" NPT TJ-80A 2" NPT 2" ASME INSPECTION OPENING (PLUGGED) 26 1/2" Horizontal or Vertical Mounting Options Available 2" NPT FRONT & REAR 2" NPT FRONT & REAR 2" NPT FRONT & REAR ASME PLATE UNDER COVE R ASME PLATE UNDER COVE R 54 7/8" 54 7/8" 42 3/4" 3/4" NPT REAR 32 1/4" 54 7/8" 42 3/4" 32 1/4" Cement or Epoxy Linings Available ASME Construction 3/4" NPT REAR TJV-120M 2" NPT FRONT & REAR 2" NPT FRONT & REAR 1" NPT FRONT 2" NPT 3/4" NPT (ANODE ) 3/4" NPT (ANODE ) TJ-80A 42 1/4" 15" 2" NPT FRONT 1" NPT FRONT 1" NPT FRONT 2" NPT FRONT 2" NPT FRONT 2" NPT FRONT 42 1/4" 4 1/8" 4 1/8" 54 7/8" 26 1/2" 3/4" NPT 19 1/2" (ANODES) 3/4" NPT 11" 9 3/4" FRONT 21 1/4" 2" NPT 9 3/4" FRONT & REAR 2" ASME INSPECTION 2" NPT OPENING (PLUGGED) 64" 3/4" NPT TJV120M Jacketed-Vertical Only** TJ80A Jacketed-Vertical Only*** TJV-120A*** TJV-200M (ASME)** 63 62 54-7/8 61-3/4 77 25-1/4 29-3/8 26-1/2 28 32 236 320 369 411 560 Plant of Manufacture: *Renton, Washington only **McBee, South Carolina only ***Both McBee, South Carolina and Renton, Washington 51 1/4" 7/8" 21 17 3/4" 47" 109 3/4" 3/4" 2" ASME INSPECTION OPENING (PLUGGED) 16" 7" 2" NPT 2" ASME INSPECTION 2" ASME INSPECTION OPENING (PLUGGED) 32 " OPENING (PLUGGED) 3 3/4" 1" NPT 3/4" NPT 3/4" NPT ) 77(ANODE " 64" 80 119 80 119 175 63" TJ TJV-200M 2" NPT 77 " Approx. Shipping Weight (lbs) 44 1/2" 17 3/4" 10 3/4" TJV-120M 1" NPT Diameter (Inches) 2" NPT FRONT 3/4" NPT 50 1/2" 2" NPT FRONT & REAR 44 1/2" 61 3/4" 3/4" NPT LOCA TED UNDER 50 1/2" COVE R 1" NPT 2" NPT 32 " Overall Length (Inches) 2" ASME INSPECTION OPENING (PLUGGED) 61 ASME 3/4" PLATE 2" NPT FRONT 3/4" NPT FRONT REAR 2" ASME INSPECTION OPENING (PLUGGED) ASME PLATE LOCA TED UNDER COVE R 3/4" NPT 21 1/4" 2" NPT FRONT (ANODES) & REAR 9 3/4" (ANODES) NPT 323/4" " 2" ASME INSPECTION OPENING (PLUGGED) 28" 1" NPT 1" NPT TJV-200M 3/4" NPT REAR 3/4" NPT 2" NPT FRONT & REAR 3/4" NPT FRONT Nominal Gallon Capacity 2 1-1/4" NPT (ANODE ) 1" NPT 28" ASME PLATE UNDER COVE R 3/4" NPT 50 1/2" 44 1/2" 2" ASME INSPECTION OPENING (PLUGGED) OPTIONAL TJV-120A 2" ASME INSPECTION 28" OPENING (PLUGGED) 61 3/4" 4 1/8" 42 3/4" FRONT & REAR 32 1/4" 3 1/2" 3/4" NPT FRONT 2" NPT FRONT & REAR 1" NPT 2" NPT 2" NPT FRONT 11" TJV-200M 2" NPT 3 1/2" 11" • For complete warranty information, consult 3 1/2" written warranty or go to hotwater.com. 15" 11" 3/4" NPT REAR 1-1/4" NPT (ANODE ) 1" NPT 2" NPT FRONT & REAR 54 1/4" 15" 3 3/4" 3/4" NPT REAR 2" NPT 2" NPT TJV-200M 54 1/4" 3 3/4" TJV-120A 1" NPT 62" 5-Year Heat Exchanger and 1-Year Parts Limited Warranty 7" 3/4" NPT REAR 62" 42 1/4" 2" NPT FRONT & REAR 16" 7" 29 3/8" 29 3/8" 54 1/4" 3/4" NPT FRONT 47" TJV-120A 2" NPT 3/4" NPT (ANODE ) 62" 47" TJV-120M 29 3/8" 2" NPT FRONT 51 7/8" 16" 16" 2" ASME INSPECTION 2" ASME INSPECTION 3/4" NPT 7" OPENING (PLUGGED) OPENING (PLUGGED) REAR 3/4" NPT (ANODE ) Meets R12.5 Minimum Thermal Insulation Requirements of the U.S. Department of Energy and Current Edition of ASHRAE/IESNA 90.1 63" 3/4" NPT FRONT 51 7/8" 3 3/4" TJV-120M lack Steel, Stainless and SiliconB Bronze Tank Constructions Available TJ80S Jacketed-Vertical Only** 3/4" NPT REAR 3/4" NPT REAR 63" 3/4" NPT FRONT 3/4" NPT REAR 2" NPT Model Number 2" NPT FRONT & REAR 3/4" NPT 51 7/8" 47" FRONT 2" ASME INSPECTION OPENING (PLUGGED) 25 1/4" 2" NPT FRONT & REAR 3/4" NPT REAR 19 1/2" 11" 9 3/4" 2" NPT FRONT & REAR 2" NPT FRONT & REAR 25 1/4" 3/4" NPT REAR 63" 32 1/4" 19 1/2" 11" 9 3/4" 3/4" NPT FRONT 19 1/2" 11" 9 3/4" 42 3/4" 3/4" NPT (ANODE ) 3/4" NPT (ANODE ) 2" ASME INSPECTION OPENING (PLUGGED) 25 1/4" ASME PLATE UNDER COVE R High-Density, Fiberglass Insulated Jackets or Bare Steel Tanks Anodic Protection 2" NPT 2" ASME INSPECTION 26 1/2" OPENING (PLUGGED) 26 1/2" TJ-80S 2" NPT 2" NPT 1" NPT 2" NPT Glasslined per ASME, HLW Procedures TJ-80S TJ-80S 3/4" NPT1" NPT (ANODE ) 3/4" NPT 3/4" NPT (ANODES) 2" NPT 2" NPT ASME RATING PLATE AND HAND HOLE LOCATED UNDER COVER ASME RATING PLATE AND HAND HOLE LOCATED UNDER COVER 1" NPT 2" NPT 77 " 2" ASME INSPECTION 17 1/4" 17 1/4" 17 1/4" 12 12 1/4" 12 1/4" 1/4" OPENING (PLUGGED) 17 1/4" 29 3/8" 64" ASME RATING PLATE AND 12 1/4" HAND HOLE LOCATED UNDER COVER 17 1/4" 12 1/4" 17 1/4" 12 1/4" 1" NPT FRONT 2" NPT 32 " 2" NPT FRONT 1" NPT 62" 54 1/4" 2" NPT FRONT 42 1/4" 77 " 3/4" NPT 61 3/4" 3/4" NPT 2" NPT 50 1/2" 44 1/2" ASME RATING PLATE AND HAND HOLE LOCATED UNDER COVER 21 1/4" TJV-200M 64" 15" 11" 3/4" NPT (ANODES) 4 1/8" 3 1/2" 9 3/4" 2" NPT FRONT & REAR 17 1/4" 12 1/4" 17 1/4" 12 1/4" 3/4" NPT FRONT 2" ASME INSPECTION OPENING (PLUGGED) 2" NPT 32 " 1" NPT 3/4" NPT 2" NPT 77 " 64" 152 17 1/4" 12 1/4" ASME RATING PLATE AND HAND HOLE LOCATED UNDER COVER 17 1/4" 12 1/4" 153 COMMERCIAL STORAGE TANKS CUSTOM-LINE FACTORY JACKETED & INSULATED STORAGE TANKS Glasslined per ASME, HLW Procedures Horizontal or Vertical Mounting Options Available G G I* E High-Density, Fiberglass Insulated Jackets or Bare Steel Tanks I D A 3/4" Cement or Epoxy Linings Available 1" ASME Construction G G Anodic Protection B C F lack Steel, Stainless and SiliconB Bronze Tank Constructions Available H *Note: These connections are not for piping connections. They are the anode locations and also serve as the required ASME 2” inspection openings. H STORAGE TANK SELECTION Meets R12.5 Minimum Thermal Insulation Requirements of the U.S. Department of Energy and Current Edition of ASHRAE/IESNA 90.1 OPTIONAL G I* E-NPT E-NPT I* I* 1" NPT 3/4" NPT D B D I E-NPT E-NPT 5-Year Limited Tank Warranty E-NPT A • For complete warranty information, consult written warranty or go to hotwater.com. 3/4" NPT F J 2" PLUG E H *Note: These connections are not for piping connections. They are the anode locations and also serve as the required ASME 2” inspection openings. H C Model Number & Gallon Capacity TJV-140 TJV-200 TJV-250 TJV-350 TJV-400 TJVT-500 TJV-500 TJV-750 TJV-1000 154 Dimensions in Inches A B 87 83 96 97 105 100 84 116 150 30 36 36 42 42 48 54 54 54 C D E F 21-1/2 51 8 1-1/2 22 45 10 1-1/2 22 58 10 1-1/2 24-1/2 54 14 1-1/2 24-1/2 61 14 1-1/2 27 52 16 1-1/2 27-3/4 33-1/4 18 1-1/2 27-3/4 65-1/2 18 1-1/2 27-3/4 97-1/2 18 1-1/2 G 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 3 3 3 3 H “I” ASME Inspection Openings 6-3/8 2 7-3/4 2 7-3/4 2 9-1/2 2 9-1/2 2 11-5/16 12 X 16 12-3/4 12 X 16 12-3/4 12 X 16 12-3/4 12 X 16 G Model Number & Gallon Capacity Dimensions in Inches A B 41 41 TJH-350 47 TJH-400 47 TJHT-500 53 TJH-500 59 TJH-750 59 TJH-1000 59 36 36 42 42 48 54 54 54 TJH-200 TJH-250 C D 77 16 90 15 93 17-1/2 99 17-1/2 94 21 79 22-3/4 111 22-3/4 143 22-3/4 E F 2-1/2 2-1/2 2-1/2 2-1/2 3 3 3 3 11 11 10 10 11 12 12 11 G H “I” ASME Inspection Openings J 23 16 2 1-1/2 23 22-1/2 2 1-1/2 26 22-1/2 2 1-1/2 26 26 2 1-1/2 29 19-1/2 12 X 16 1-1/2 32 11 12 X 16 1-1/2 32 27 12 X 16 1-1/2 32 43 12 X 16 1-1/2 155 COMMERCIAL STORAGE TANKS UNINSULATED STANDARD STOCK BARE STORAGE TANKS Model Number T-80 STD T-120 STD T-200 STD Glasslined per ASME, HLW Procedures T-350 STD Horizontal or Vertical Mounting Options Available T-200 ASME High-Density, Fiberglass Insulated Jackets or Bare Steel Tanks T-325 ASME T-250 ASME Cement or Epoxy Linings Available OPTIONAL T-140 ASME T-350 ASME T-400 ASME TN-500 ASME ASME Construction T-500 ASME Anodic Protection T-1000 ASME lack Steel, Stainless and SiliconB Bronze Tank Constructions Available Model Number T-750 ASME T-80 STD Meets R12.5 Minimum Thermal Insulation Requirements of the U.S. Department of Energy and Current Edition of ASHRAE/IESNA 90.1 T-120 STD 5-Year Limited Tank Warranty T-200 ASME • For complete warranty information, consult written warranty or go to hotwater.com. T-200 STD T-350 STD T-140 ASME T-250 ASME T-325 ASME T-350 ASME T-400 ASME TN-500 ASME T-500 ASME T-750 ASME T-1000 ASME Model Number T-80 STD T-120 STD T-200 STD T-350 STD 2” ASME INSPECTION/ANODE OPENING 2” ASME INSPECTION/ANODE OPENING (ON 36” DIAMETER AND BELOW) (ON 36” DIAMETER AND BELOW) 12”x 16” ASME INSPECTION OPENING (ON 42” DIAMETER AND ABOVE) 12”x 16” ASME INSPECTION OPENING (ON 42” DIAMETER AND ABOVE) T-140 ASME T-200 ASME T-250 ASME T-325 ASME T-350 ASME T-400 ASME TN-500 ASME T-500 ASME T-750 ASME T-1000 ASME 156 Gallon Capacity Overall Dimensions in Inches Approx. Shipping Weight (lbs) 80 119 200 350 140 200 250 325 350 400 500 500 750 1000 20 X 62-1/8 24-1/4 X 65 30 X 72 36 X 88 24 X 76-1/4 30 X 72 30 X 84 34 X 84 36 X 88 36 X 97 42 X 89 48 X 74 48 X 106 48 X 138 170 287 460 670 400 460 505 600 670 775 815 950 1290 1655 Dimensions in Inches A B C D E F 20 24-1/4 30 36 24 30 30 34 36 36 42 48 48 48 61-1/2 64-3/8 70-3/4 86 75 70-3/4 84 84 86 96 88 72-3/4 105 136 2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 3 3 3 3 n/a n/a 10 14 8 10 10 14 14 14 16 18 18 18 7 7 13 16 12 13 13-1/4 16 16 16 18 18 19-3/4 19-3/4 2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 3 3 3 3 G H J K N P 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 46-1/4 34-1/2 28-1/2 31-1/2 27-1/2 28-1/2 28-1/2 28-3/4 31-1/2 31-1/2 33-1/2 32-3/4 32-3/4 32-3/4 16 15-1/2 19-1/2 20-1/4 18-1/2 19-1/2 19-1/2 19-3/4 20-1/4 20-1/4 24-1/2 26-3/4 26-3/4 26-3/4 3-1/2 10-1/2 13 16 12 13 13 13-3/4 16 16 18 19-3/4 19-3/4 19-3/4 3-1/4 3-1/2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4 4-1/8 4 4 4 4 4 5 4 4 5 6 6 6 Dimensions in Inches 157 COMMERCIAL STORAGE TANKS HEAVY-DUTY LARGE VOLUME STORAGE TANKS MODEL HD CUSTOM BUILT Glasslined per ASME, HLW Procedures Horizontal or Vertical Mounting Options Available High-Density, Fiberglass Insulated Jackets or Bare Steel Tanks Cement or Epoxy Linings Available ASME Construction Anodic Protection lack Steel, Stainless and Silicon-Bronze B Tank Constructions Available OPTIONAL Model Number HD20-80 HD20-100 HD24-125 HD24-140 HD24-175 HD30-175 HD30-200 HD30-250 HD30-300 HD36-250 HD36-300 HD36-350 HD36-400 Meets R12.5 Minimum Thermal Insulation Requirements of the U.S. Department of Energy and Current Edition of ASHRAE/IESNA 90.1 HD36-500 5-Year Limited Tank Warranty HD42-600 • For complete warranty information, consult written warranty or go to hotwater.com HD42-375 HD42-450 HD42-500 HD42-700 HD42-800 HD48-500 HD48-600 HD48-700 HD48-750 HD48-900 HD48-1000 HD48-1250 HD48-1500 HD54-650 HD54-750 HD54-900 HD54-1000 HD54-1250 HD54-1500 HD54-1800 HD60-800 HD60-1000 HD60-1250 HD60-1500 HD60-1750 Shipping Weight (lbs.) Nominal Gallon Capacity Dimensions Diameter x O.A. Length (Inches) Black Steel 80 100 125 140 175 175 200 250 300 250 300 350 400 500 375 450 500 600 700 800 500 600 700 750 900 1,000 1,250 1,500 650 750 900 1,000 1,250 1,500 1,800 800 1,000 1,250 1,500 1,750 20 x 60 20 x 72 24 x 66 24 x 75 24 x 90 30 x 60 30 x 71 30 x 84 30 x 99 36 x 60 36 x 71 36 x 86 36 x 93 36 x 122 42 x 67 42 x 79 42 x 88 42 x 103 42 x 119 42 x 134 48 x 73 48 x 81 48 x 93 48 x 105 48 x 117 48 x 137 48 x 159 48 x 190 54 x 71 54 x 81 54 x 95 54 x 105 54 x 129 54 x 153 54 x 181 60 x 72 60 x 88 60 x 107 60 x 126 60 x 146 210 294 420 438 489 575 657 740 803 873 998 1,122 1,198 1,445 1,105 1,260 1,415 1,574 1,965 2,008 1,680 1,878 2,077 2,300 2,499 2,697 3,292 3,912 2,200 2,461 2,752 3,010 3,531 4,080 4,861 2,324 2,758 3,367 3,657 4,166 Glasslined Cement Epoxy 210 294 366 422 494 469 505 567 654 521 613 682 727 869 855 946 991 1,097 1,188 1,399 1,072 1,231 1,365 1,455 1,633 1,811 2,157 2,425 1,239 1,403 1,566 1,730 2,055 2,381 2,870 1,769 2,061 2,491 2,679 3,126 – – – – – 870 990 1,109 1,238 984 1,121 1,260 1,340 1,616 1,299 1,480 1,679 1,885 2,202 2,451 1,750 1,984 2,216 2,468 2,715 3,023 3,639 4,337 2,061 2,327 2,613 2,936 3,408 3,959 4,756 2,509 3,011 3,706 4,101 4,712 Line drawing and dimensions on the following page. 158 159 COMMERCIAL STORAGE TANKS HEAVY-DUTY LARGE VOLUME STORAGE TANKS MODEL HD CUSTOM BUILT CUSTOM-LINE STORAGE TANKS (20” THRU 96” DIA. TANKS) (CONTINUED) OVERALL A B E THREADED LEG SOCKET "C" A A ASME PLATE Model Number HD60-2000 HD66-1000 HD66-1500 HD66-2000 HD66-2500 HD72-2500 HD72-3000 HD72-3500 HD72-4000 HD84-4000 HD84-5000 HD84-6000 HD84-8000 HD96-7500 HD96-10000 HD96-12500 Nominal Gallon Capacity 2,000 1,000 1,500 2,000 2,500 2500 3,000 3,500 4,000 4,000 5,000 6,000 8,000 7,500 10,000 12,500 Dimensions Diameter x OAL (Inches) 60 x 165 66 x 75 66 x 107 66 x 139 66 x 171 72 x 147 72 x 174 72 x 201 72 x 228 84 x 173 84 x 212 84 x 252 84 x 330 96 x 244 96 x 319 96 x 395 A Shipping Weight (lbs) A Black Steel Glasslined Epoxy Cement 4,844 2,760 3,886 5,010 6,101 6,224 7,116 8,493 9,831 9,508 11,865 13,599 17,737 15,843 20,628 24,590 3,505 1,929 2,675 3,422 4,170 4,126 4,669 5,212 6,027 6,348 7,871 9,012 11,674 11,711 15,261 18,303 5,432 2,808 4,011 5,184 6,388 5,800 6,653 7,943 9,238 9,093 11,354 13,063 17,070 16,090 20,950 24,892 A A A B B A A A A NOTE: 1) 54” DIAMETER AND LARGER TANKS MUST BE ORDERED WITH ANGLE LEGS RATHER THAN THREADED LEG SOCKETS FOR VERTICAL INSTALLATIONS. 2) SPECIFY FOR HORIZONTAL OR VERTICAL INSTALLATION. 3) NO LEG SOCKETS PROVIDED ON HORIZONTAL TANKS. 2 each 2” ASME inspection openings are standard on tanks 36” diameter and below. 12”x16” ASME inspection openings are standard on tanks with 42” diameters and above. CUSTOM-LINE STORAGE TANKS (20” THRU 96” DIA. TANKS) OVERALL A 1-1/4" CONTROL OPENING B E A ASME PLATE A A A A A B A A B A A T&P VALVE OPENING A A B NOTE: 1) ADD SUFFIX “ES” FOR SINGLE - WALL OR “ED” FOR DOUBLE - WALL TO MODEL NUMBER WHEN EQUIPPED WITH A TUBE TANK HEATER (i.e.: HD-36-350ES). 2) SPECIFY FOR HORIZONTAL OR VERTICAL INSTALLATION. 3) NO LEG SOCKETS PROVIDED ON HORIZONTAL TANKS. A A A A OVERALL ASME PLATE ALL DIMENSIONS IN INCHES B DIMENSION CHART DIMENSION A B C D E E 20 2 3/4 1 1/2 6 3/4 24 THRU 36 2 1/2 3/4 2 1/2 8 1 42 AND 48 3 54 THRU 96 3 3/4 3/4 3 10 3 1 10 1 A B D A THREADED LEG SOCKET "C" Tank Saddles A.O.Smith Tank A Part Number Diameter P2-2600-20 B P2-2600-24 P2-2600-30 P2-2600-36 P2-2600-42 P2-2600-48 5’ (NOM.) A P2-2600-54 P2-2600-60 P2-2600-66 P2-2600-72 P2-2600-84 P2-2600-96 160 20 24 30 36 42 48 54 60 66 72 84 96 22 26 32 38 44 50 56 62 58 74 86 98 B 6 6 6 6 6 6 8 8 8 10 10 10 161 COMMERCIAL WATER HEATER AC-U-TEMP COMPLETE HOT WATER SYSTEMS Standard Tank Sizes from 80 to 1000-Gallons Ac-U-Temp System Eliminates Costly Field Errors Simplifies Installation Standard Ac-U-Tanks are Factory Jacketed and Insulated All Systems are Built to Order Multi-Heater Systems for 50%100% Back-Up Multi-Tank Systems Available Superior I-Beam Skid Factory Hydrostatic and Fire-Tested Before Shipping ASME Relief Valve 125# Tank Temperature Sensor Tank Thermometer Isolation Valves Custom Tank Sizes to 10,000 Gallons 5-Year Limited Heat Exchanger Warranty and 5-Year Limited Tank Warranty • For complete warranty information, consult written warranty or go to hotwater.com. INSTANTANEOUS SEMI-INSTANTANEOUS HWI WATER HEATERS A. O. Smith’s HWI Models are Available for Operation with Steam or Boiler Water as the Energy Source. They are Factory Assembled with Components Sized, Piped and Checked at the Factory Before Shipment. HWI Models are All Space Saving Vertical Models. Code Listing-the System Will Employ an ASME ”U” Code Shell. Fitted with an ASME “U” Code 3/4” Diameter Copper Tube Heat Exchanger. Integral Pump-the HWI System Will Employ an Integral Bronze Circulator Pump. Steam Units - Steam Trim Consists of Temperature Control Valve, Inlet and Auxiliary Steam Traps, Inlet and Auxiliary Strainers, Steam Pressure Gauge with Siphon, Vacuum Breaker and Air Vent. oiler Units-Boiler Water Trim B Includes Temperature Control Valve and Boiler Water Temperature Gauge. Control Features • Single Point Wiring – Single 120V Connection, Controls Including Integral Circulation • On/Off Switch-Allows Local On/Off for Service • Temperature Readout – LED readout of water temperature • PID Temperature Control – Modulates electrical control valve • High Temperature Limit – Closes main valve under over temperature condition • Remote Temperature Signal • 2-Wire RS485 – Communication (MODBUS or ASCII) 162 163 A. O. Smith | 500 Tennessee Waltz Parkway | Ashland City, TN 37015 800.527.1953 | hotwater.com AOSAA80000 | ©2015 A. O. Smith Corporation | Printed in U.S.A.