resort municipality of whistler whistler gateway loop redevelopment
Transcription
resort municipality of whistler whistler gateway loop redevelopment
3 2 SAVED 2016-05-31 10:28 AM 1 5 4 6 7 P261 N ROAD LORIMER E Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm E millimeters 100 PROJECT LOCATION B WAY BLACKCOM 0 SKY O T SEA 10 HIG #99 Y A HW LVD B NDS A L RTH O N D 50 D LOCATION PLAN Scale: 1:25,000 KWL - CIVIL D BLV E T E GA G P248 A VILL C SITE LOCATION N.C. PUBLIC - ARCHITECTURAL DWG DRAWING DESCRIPTION DWG DRAWING DESCRIPTION G-001 LOCATION MAP, SITE PLAN, DRAWING INDEX A1.01 SITE PLAN, LEGENDS AND SCHEDULES G-002 EXISTING SITE CONDITIONS, LEGEND A2.01 L1 PLAN G-003 PROPOSED COMPREHENSIVE SITE PLAN A2.02 ROOF PLAN G-004 ISOLATION AND REMOVALS A3.01 L1 RCP C-101 GRADING PLAN A5.01 ELEVATIONS AND SECTIONS C-102 ROAD GEOMETRICS A5.11 SECTIONS AND DETAILS C-201 GATE WAY LOOP & BUS LOOP PROFILE FAST+EPP - STRUCTURAL C-301 SECTIONS DWG DRAWING DESCRIPTION C-103 ROAD PAINTING AND SIGNAGE S1.00 GENERAL NOTES - SHEET 1 C-104 SANITARY & WATER SERVICES S1.01 GENERAL NOTES - SHEET 2 S2.00 FOUNDATION PLAN KWL - ELECTRICAL B Golf Course PRV P249 PRV Municipal PSV GENERAL NOTE O:\0000-0099\029-264\501-Drawings\a_Production_Dwgs\29 264 G 001.dwg DWG DRAWING DESCRIPTION S2.10 ROOF FRAMING PLAN E-101 SITE PLAN S2.11 ROOF PREFAB PANEL PLAN E-102 SINGLE LINE DIAGRAM S2.12 ROOF CLT PANEL PLAN E-103 LIGHTING AND RECEPT. WIRING DIAGRAM S4.00 SECTIONS AND DETAILS E-104 KIOSK LAYOUT S4.10 SECTIONS AND DETAILS E-105 BUS SHELTER ELECTRICAL DISTRIBUTION S4.11 SECTIONS AND DETAILS E-106 BENCH/CURB, HEAT TRACE, AND JB DETAILS S4.12 SECTIONS AND DETAILS S4.13 SECTIONS AND DETAILS P+A - LANDSCAPE PSV ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE RESORT MUNICIPALITY OF WHISTLER SUBDIVISION AND SERVICING BYLAW, SUPPLEMENTED WITH THE MASTER MUNICIPAL CONSTRUCTION DOCUMENTS (MMCD). N.C. DWG DRAWING DESCRIPTION L1.0 LANDSCAPE PLAN L1.1 LIGHTING PLAN L2.0 GRADING PLAN L3.0 PLANTING PLAN L4.0 IRRIGATION PLAN L5.0 ILLUSTRATIVE LANDSCAPE SECTIONS L6.0 LANDSCAPE DETAILS L6.1 LANDSCAPE DETAILS L6.2 LANDSCAPE DETAILS L6.3 LANDSCAPE DETAILS SITE PLAN Scale: 1:2000 Seal: Rev 0 Date Des Dwn Chk 2016-05-31 FFF CAP Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER Group 2 3 4 5 6 A RESORT MUNICIPALITY OF WHISTLER WHISTLER GATEWAY LOOP REDEVELOPMENT GENERAL LOCATION MAP, SITE PLAN & DWG INDEX Project No. 1 B RESORT MUNICIPALITY OF WHISTLER WHISTLER GATEWAY LOOP REDEVELOPMENT KWL CONTRACT 29.264 P257 A C 29.264 GENERAL Drawing No. Rev. G001 7 0 3 2 SAVED 2016-05-31 10:24 AM 5 4 669.36 669.45 669.53 669.70 669.71 669.70 669.76 669.71 669.80 669.84 669.87 669.70 669.93 669.74 670.09 670.13 670.19 670.14 669.76 670.24 SL N 670.24 670.19 670.21 670.26 670.18 SL 670.31 670.15 W E 670.21 670.28 670.15 670.19 670.23 670.30 670.29 670.32 670.33 670.37 670.35 670.38 670.45 SL SL SL 670.25 670.37 T TELEPHONE MAIN T t TELEPHONE SERVICE t COMBINED TEL/CABLE SERVICE t-c E-T-C COMBINED ELEC/TEL/CABLE MAIN E-T-C COMBINED ELEC/TEL/CABLE SERVICE G g GAS SERVICE g SL STREET LIGHT MAIN SL TR TRAFFIC SIGNAL MAIN TR 670.88 670.58 670.72 670.69 670.75 670.80 670.69 670.76 w 670.99 671.02 671.08 671.32 s REDUCER LP END CAP PIPE POST 671.27 EDGE OF GRAVEL ROADS / DRIVEWAYS 671.89 E 671.85 E 671.96 672.08E 672.29 672.12 671.57 672.31 672.20 E 671.93 SURVEY CONTROL 672.82 672.82 672.83 672.70 672.68 GSL SITE COORDINATES ARE GROUND LEVEL DISTANCES IN METRES. TO COMPUTE GRID DISTANCES, MULTIPLY GROUND LEVEL DISTANCES BY COMBINED SCALE FACTOR OF 0.99949718 AT KWL SPIKE 5751. 673.21 G ELEVATION DATUM IS GEODETIC BASED ON TIES TO HBO MONUMENT 4559, BRASS MONUMENT AT THE WAR MEMORIAL CENOTAPH, ELEVATION = 672.184m 673.21 671.97 671.86 671.78 672.07 672.59 672.65 E 672.05 672.79 672.86 E HORIZONTAL COORDINATE ORIGIN IS UTM NAD 83 AT KWL SPIKE 5751 BASED ON STATIC RTK GPS OBSERVATIONS. 672.06 672.57 672.85 G SURVEY CONTROL INSPECTION CHAMBER TOPOGRAPHY 672.87 E DISTRICT LOT 672.82 672.77 672.74 G 672.77 672.02 672.00 671.96 E W 671.82 671.76 671.78 671.81 671.77 W 671.68 KWL 5755 672.98 672.979 671.84 672.67 w CLEAN-OUT (BELOW SURFACE) W E SL 672.80 672.81 672.81 672.80 G 672.81672.81 w EASEMENT / RIGHT-OF-WAY MANHOLE E 672.75 672.09 672.28 672.19 672.36 G 672.15 672.45 672.48 672.50 w LOT CLEAN-OUT (ABOVE SURFACE) B G 672.69 W LEGAL 672.70 672.19 672.12 672.71 672.69 E 672.00 672.44 672.68 W s 672.33 672.60 672.57 E s SERVICE CONNECTION S 672.55 672.58 SANITARY s 672.62 671.94 672.16 672.45 SL 671.76 671.85 W FLOWPATH - OVERLAND E 671.92 672.43 672.59 672.61 672.48 671.89 671.67 671.93 672.50 E 672.38 672.42 672.23 672.35 E 671.93 672.08 E E FLOWPATH - MINOR (DITCH OR SWALE) E 672.38 671.83 671.63 671.72 W 671.60 HYDROLOGY EDGE OF CONCRETE OR PAVERS PATH 671.50 671.74 E 672.24 SL FLOWPATH - MAJOR (CREEK OR RIVER) E E 1 EDGE OF GRAVEL PATH MAIN E 672.23 BORE HOLE EDGE OF PAVED PATH 671.74 671.49 672.58 GEOTECHNICAL WHEEL PATH S E E 672.31 PAINT LINES - URBAN LANES 671.74 S 671.30 671.42 671.55 671.34 671.66 671.77 672.00 PAINT LINES - BROKEN 3.0 m PAINT LINES - RURAL LANES S 672.01 671.59 ALIGNMENT EXTENTIONS S SL 672.18 SL PAINT LINES - BROKEN 1.0 m S 671.55 671.64 671.70 671.49 671.53 ALIGNMENTS / CENTRELINES 671.74 671.39 671.50 671.44 ALIGNMENTS PAINT LINES - BROKEN 0.5 m B 671.42 671.41 EDGE OF CONCRETE/PAVER ROADS/DRIVEWAYS E S 671.53 671.59 671.95 671.36 E 671.33 671.35 SPRINKLER HEAD 671.50 S 671.75 671.31 671.28 671.35 671.36 671.39 KWL 5753 671.48 671.38 671.37 671.65 S E THRUST BLOCK EDGE OF PAVED ROADS / DRIVEWAYS 671.32 G 671.32 671.56 S 671.27 671.24 671.25 671.480 671.42 671.44 671.37 CORP. STOP / CURB STOP ROADS G 671.25 671.44 671.33 S HYDRANT 671.31 G E VALVE IP 671.24 S 671.30 G 671.24 671.21 671.49 SL OPP w 671.39 671.37 671.35 671.19 SL OLP s LEAD PLUG 671.22 671.19 671.88 671.38 671.35 C 671.54 671.38 671.20 E OIP SERVICE CONNECTION 671.13 671.88 671.47 671.17 SL IRON PIN 671.12 MAIN w 671.16 671.13 671.67 671.46 671.41 671.31 671.13 671.24 671.29 671.90 671.49 SL 671.50 671.05 671.18 671.16 SL MON 75H45632MONUMENT 100.000 KWL/1234 SURVEY TAG 100.000 TBM TEMP. 1 BENCH MARK 100.000 G 671.61 G 671.14 671.12 671.89 671.50 671.36 671.27 671.13 671.23 WATER 671.43 671.41 671.41 671.07 671.08 671.07 671.10 671.06 671.13 SURVEY 670.99 671.44 672.33 671.14 E LAWN EDGE 671.74 671.34 671.30 671.08 671.15 671.13 671.16 SL 671.07 671.30 G 671.12 671.05 671.09 671.03 BUSH LINE / HEDGE LINE CONTOUR - MINOR 671.39 SL 671.02 670.99 670.99 TREE LINE 671.27 671.02 670.95 VEGETATION 671.59 E STREET LIGHT (DOUBLE DAVIT) CONTOUR - MAJOR 670.93671.06 671.30 671.24 SL 670.93 670.84 670.97 670.90 RETAINING WALL - ROCK SURFACES 670.91 SL 670.97 671.52 670.95 670.95 670.98 STREET LIGHT (SINGLE DAVIT) RETAINING WALL 670.91 670.93 670.88 670.80 670.93 671.02 671.03 670.87 SL 670.91 670.73 670.72 671.16 671.14 671.21 670.98 671.58 671.28 671.19 671.03 671.07 671.13 671.11 671.04 671.45 G 671.03 671.05 670.95 670.85 670.95 670.97 670.83 670.85 670.83 670.83 670.87 SL 670.88 670.64 670.69 670.75 670.77 671.34 671.15 E ROADSIDE BARRIER - CENTERED 670.76 670.86 w 670.87 STREET LIGHT (POST TOP) D 670.55 670.63 670.85 w 670.67 670.69 670.71 w 670.74 670.78 670.78 670.80 670.78 GAS MARKER GUARDRAIL 669.69 670.26 671.15 670.64 670.71 670.75 670.73 GAS VALVE FENCE - BARBED & GENERAL 669.11668.98 669.24 KWL 5754 669.32 669.37 669.318 669.47 670.37 671.36 671.29 671.16 670.88 670.88 w 670.61 670.68 TRANSFORMER FENCE - POST & RAIL C 670.672 JUNCTION BOX FENCE - CHAINLINK 670.61 670.65 670.57 KWL 5756 670.67 670.94 671.20 670.95 671.13 670.98 671.04 670.85 670.86 670.52 670.64 670.66 670.64 670.64 SERVICE BOX CABLE BARRIER WITH POSTS 670.86 E GENERAL STRUCTURES 669.94 669.98 SL STRUCTURES GAS MAIN 669.64 670.52 670.60 e-t-c G 670.81 670.97 W MANHOLE 670.47 E e-t-c CATCH BASIN MANHOLE 10 t-c 669.80 SL INSPECTION CHAMBER 670.59 T-C 669.80 670.91 670.91 670.84 G HEADWALL 0 COMBINED TEL/CABLE MAIN T/C CLEAN-OUT (SUBSURFACE) 669.22 671.65 670.54 670.46 669.52 669.93 669.91 669.87 670.09 670.41 s 50 CLEAN-OUT 670.48 SL CATCH BASIN (SIDE INLET) 670.02 669.99 670.79 670.53 670.52 670.01 670.16 669.86 669.94 SL CATCH BASIN (STANDARD) e 670.28 D 670.11 SL e SL 669.14 669.01 SL 669.33 D 669.69 671.69 SL LAWN DRAIN 669.88 670.17 670.88 L 670.80S 670.49 670.36 670.35 G 669.52 SL E 670.37 SL SL ELECTRICAL MAIN ELECTRICAL SERVICE CONNECTION E 670.47 669.02 G SERVICE CONNECTION 670.44 669.19 D 670.31 G c 670.49 670.53 SL CABLE SERVICE CONNECTION 670.63 670.60 669.89 SL c 670.71 670.66 669.32 E D d 670.75 670.74 670.73 670.71 E PERFORATED PIPE SL SL 669.93 D 670.86 SL C 670.15 G CABLE MAIN 670.09 670.09 670.08 670.06 G G C 670.78 670.93 s D d D G 670.24 669.45 669.76 669.76 669.73 669.73 669.73 G 669.67 669.74 SL 670.85 670.76 670.34 s MAIN 670.46 670.30 670.45 670.90 670.81 671.59 670.48 670.47 670.40 670.45 670.32 669.59 669.84 669.83 669.85 s D 670.41 670.42 670.84 670.78 670.78 s D UTILITIES 670.49 G 669.75 669.73 669.78 669.78 669.77 669.98 670.73 670.22 SL STORM 670.53 670.19 670.16 670.80 670.29 670.32 PROPOSED 670.57 670.74 SL EXISTING 670.59 G 670.78 G PROPOSED 670.73 670.74 670.74 670.75 670.76 670.16 670.53 EXISTING 670.69 670.71 670.18 670.22 670.61 SL 100 670.18 670.16 670.60 D 670.71 W 670.09 D 670.66 670.70 670.71 670.68 670.69 670.71 W 669.62 670.24 SL SL SL 670.42 670.54 670.59 670.62 670.66 669.24 668.99 670.38 670.32 670.68 D 670.46 669.39 669.86 W 670.50 670.63 D 670.36 670.21 670.19 670.06 670.07 670.10 670.51 670.57 669.54 670.03 W 670.51 670.42 S 670.51 L 670.53 G G G 670.52 670.32 670.51 670.55 D SL 670.24 670.48 670.43 SL 670.25 670.25 670.19670.18 670.20 670.16 670.14 670.26 670.13 670.34 670.12 670.40 670.44 670.22 670.24 LEGEND 671.78 671.71 G TOE OF BANK w TOP OF BANK w E SOIL - TOPSOIL E O:\0000-0099\029-264\501-Drawings\a_Production_Dwgs\29 264 G 002.dwg 670.637 D 670.28 670.31 670.25670.26 670.24 670.24 670.23 669.61 670.20 W 670.50 KWL 5751 670.64 G G 670.33 G D 670.48 670.45 670.41 670.38 SL 670.23 670.25 670.50 SL SL SL 670.11 G 670.10 669.70 669.68 W SL SL 670.17 670.15 G G 669.91 SL 670.09 D D E 670.08 W SL 670.03 670.06 670.07 670.07 670.04 670.06 670.12 W SL Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm W 669.96 SL 670.03 669.98 669.95 669.95 669.96 669.95 669.94 SL 669.97 670.13 670.12 670.17 670.13 W 670.09 SL 669.96 670.23 G 669.80 670.04 G SL 669.69 670.00670.02 669.99 669.98 669.97 669.97 669.94 669.97 670.06 G 669.58 669.64 669.63 SL SL 669.54 670.28 millimeters 7 669.95 669.53 669.47 6 SL 1 EXISTING SITE CONDITIONS PLAN A A Scale: 1:250 Seal: Rev 0 Date Des Dwn Chk 2016-05-31 FFF CAP Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER RESORT MUNICIPALITY OF WHISTLER WHISTLER GATEWAY LOOP REDEVELOPMENT GENERAL EXISTING SITE CONDITIONS & LEGEND Project No. Group 1 2 3 4 5 6 29.264 GENERAL Drawing No. Rev. G002 7 0 5 E 503140 E 503120 E 503100 E 503080 6 7 SL SL E 503060 SL 4 E 503160 3 2 E 503040 SAVED 2016-05-30 4:24 PM 1 00 0+0 SL N E W W E W W W W W G G G G G D G C 6 G SL G D SL D G D 0 04 0+ G D G SL G SL SL G SL D G SL SL SL D 0+ 0 +0 SL 20 SL G D 0 PEDESTRIAN CROSS-WALK D D 22 SL CAR PARKING W/ EV CHARGING N 5551540 SL 100 W W G D W 239 SL SL SL SL SL SL 0+020 D W 0+ SL SL SL D W SL SL SL 0+000 SL SL SL SL SL KWL 5751 670.637 SL Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm N 5551560 R.V. PARKING G SL millimeters C5 KWL 5754 669.318 D D C 7 SL G 0+ 06 40 0+0 SL 50 0 SL SL 0+100 SL w 0+120 PEDESTRIAN CROSS-WALK PROPOSED CONCRETE SWALE w SL G w 0+140 SL w 10 SL G PROPOSED CURB AND GUTTER KWL 5756 670.672 N 5551520 0+200 0+080 0 d CAR PARKING s s E w BUS PARKING G s SL d 1 SL C SL C4 w SL w SL D SL s w 0 06 s D 0+ SL G D C SL s G D SL s d G D d G s E SL D d d d d G PROPOSED BUS SHELTER D BY OTHERS G G G d SL SL N 5551500 0+180 d E D PROPOSED CURB AND GUTTER D C s SL D 0+ 0 08 SL RAISED PEDESTRIAN CROSS-WALK S S S S S S D S E S KWL 5753 671.480 S RAISED PEDESTRIAN CROSS-WALK S SL E E E E E E 0+ E E E 160 SL E G PROPOSED LANDSCAPING BY OTHERS E E E E E E N 5551480 E SL E G 10 0+ B E 0+140 E 0 E 2 RAISED PEDESTRIAN CROSS-WALK 0+120 G C SL G E SL 3 W SL B C E W E G W W G G s E E E E G SL E W G E W W W G E E E w GSL TAXI PARKING w KWL 5755 672.979 G G w w E E w O:\0000-0099\029-264\501-Drawings\a_Production_Dwgs\29 264 G 003.dwg G SL PROPOSED COMPREHENSIVE SITE PLAN A A Scale: 1:250 Seal: Rev 0 Date Des Dwn Chk 2016-05-31 FFF CAP Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER RESORT MUNICIPALITY OF WHISTLER WHISTLER GATEWAY LOOP REDEVELOPMENT GENERAL PROPOSED COMPREHENSIVE SITE PLAN Project No. Group 1 2 3 4 5 6 29.264 GENERAL Drawing No. Rev. G003 7 0 SAVED 2016-05-31 10:25 AM 1 3 2 5 4 6 7 N E E Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm PROVIDE TEMPORARY POWER SUPPLY TO MAINTAIN STREET LIGHTING SYSTEM(S) ON VILLAGE GATE BOULEVARD LOCATE, EXPOSE, AND TEMPORARILY ISOLATE AND CAP EXISTING STREET LIGHT SERVICES CAUTION: EXISTING TRAFFIC SIGNAL & LOOP DETECTORS TO BE PROTECTED REMOVE CB AND TEMPORARILY CAP LEAD 100 REMOVE CB AND TEMPORARILY CAP LEAD millimeters REMOVE AND DISPOSE OF ALL TREES/STUMPS/VEGETATION IN THIS AREA LOCATE, EXPOSE, AND TEMPORARILY ISOLATE AND CAP EXISTING IRRIGATION SERVICES CROSSING GATEWAY DRIVE IN THIS AREA REMOVE CB AND TEMPORARILY CAP LEAD REMOVE AND RELOCATE EXISTING STREETLIGHTS (x2) SEE ELECTRICAL REMOVE AND DISPOSE OF ALL TREES/STUMPS/VEGETATION IN THIS AREA D 50 D REMOVE EXISTING HYDRO PULL BOX SEE ELECTRICAL REMOVE CB AND TEMPORARILY CAP LEAD 10 REMOVE EXISTING UNIT PAVERS WALKWAY(S) AND DELIVER TO RMOW WORKS YARD (TYP.) REMOVE LB AND CAP LEAD 0 COORDINATE W/ FORTIS BC TO RELOCATE EXISTING GAS MAIN REMOVE AND DISPOSE OF TREE REMOVE AND DISPOSE OF EXISTING ELECTRICAL KIOSK AND FOUNDATION AFTER POWER SUPPLY ISOLATION C REMOVE AND RELOCATE EXISTING STREETLIGHT SEE ELECTRICAL C REMOVE AND RELOCATE EXISTING STREETLIGHT SEE ELECTRICAL REMOVE AND DISPOSE OF EXISTING BUS SHELTER AND FOUNDATION REMOVE AND SALVAGE EXISTING BASALT ROCK RETAINING WALL REMOVE CB AND TEMPORARILY CAP LEAD COORDINATE W/ RMOW VILLAGE MAINTENANCE TO ISOLATE EXISTING IRRIGATION SUPPLY #2 ADJUST MH (x3) AND CB FRAME(S) AS REQUIRED REMOVE AND DISPOSE OF ALL TREES/STUMPS/VEGETATION IN THIS AREA COORDINATE W/ BC HYDRO TO ISOLATE POWER SUPPLY TO EXISTING KIOSK ADJUST CB AS REQUIRED ADJUST WV BOX AS REQUIRED REMOVE AND DISPOSE OF EXISTING WOOD RETAINING WALL ADJUST WV BOX AS REQUIRED REMOVE AND RELOCATE EXISTING STREETLIGHT SEE ELECTRICAL B B EXISTING HYDRO PULL BOX TO REMAIN COORDINATE W/ TELUS AND SHAW TO RELOCATE EXISTING ABOVE GRADE STRUCTURES ADJUST MH FRAMES (x3) AS REQUIRED ADJUST MH FRAME AS REQUIRED O:\0000-0099\029-264\501-Drawings\a_Production_Dwgs\29 264 G 004.dwg ADJUST WV BOX (2) AS REQUIRED COORDINATE W/ RMOW VILLAGE MAINTENANCE TO ISOLATE EXISTING IRRIGATION SUPPLY #1 REFER TO LANDSCAPE FOR REMOVAL DETAILS IN THIS AREA ISOLATIONS AND REMOVALS PLAN A A Scale: 1:250 Seal: Rev 0 Date Des Dwn Chk 2016-05-31 FFF CAP Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER RESORT MUNICIPALITY OF WHISTLER WHISTLER GATEWAY LOOP REDEVELOPMENT GENERAL ISOLATIONS AND REMOVALS Project No. Group 1 2 3 4 5 6 29.264 GENERAL Drawing No. Rev. G004 7 0 E 503140 6 E 503120 E 503100 E 503080 E 503060 E 503040 5 4 7 E 503160 3 2 SAVED 2016-05-31 8:56 AM 1 1. 2. 3. ELEVATIONS AND STATIONS ARE IN METRES. GRADE ELEVATIONS ARE SHOWN AT GUTTER INVERT OR AT PROFILE REFERENCE LINE. DIMENSIONS ARE IN MILLIMETRES. 0 +0 00 N E E KWL 5751 670.637 0+000 0+020 80 67 0.7 STANDARD GUTTER 7 10 .87 5 0.8 67 67 0 0. 12 67 0 671.28 0+140 2 BUS 6 BUS 5 1.0 671 N 5551500 60 67 85 671.4 15 170 6 150 71. 1.3 67 1.1 95 G 0 .28 67 671 50 G G G 15 KWL 5753 671.480 0 08 0+ .4 671 CB #5 SICB #6 8 1. 672.24 4 672.60 5 6 C 67 2. 2 67 2 53 8 64 0 0+120 67 64 0 672.745 .30 672 54 5 E RS VE R E R TTE GU 2 G G GRANULAR SUB-BASE - 300mm THK 75mm MINUS CRUSHED GRANULAR (OR RCA, REF. MMCD SUPPLEMENTAL UPDATE NO. 2015-11-02) COMPACTED TO 95% MODIFIED PROCTOR DENSITY 05 9 6 GRANULAR BASE - 150mm THK 19mm MINUS CRUSHED GRANULAR (TYPE 2) COMPACTED TO 95% MODIFIED PROCTOR DENSITY 67 2. G 50 2.0 0+140 672.83 0 05 672.6 5 45 . 72 70 3 67 B 0 .10 672 .060 672 G RD DA AN ER ST UTT G BOTTOM LIFT PAVING - 60mm HOT MIX AC PAVEMENT 67 2. 2. TOP LIFT PAVING - 40mm HOT MIX AC PAVEMENT .5 91 67 2. 2. 4 E RS VE ER RE UTT G 0 E RS VE TER RE UT G Scale: 1:10 10 0+ .8 71 C 67 67 2. 51 0 G 90 10 1.9 RD DA AN TER ST UT G N 5551480 5 .83 1 67 67 672.605 CB #4 0+ 67 600 BARRIER CURB W/REVERSE GUTTER 6 .67 G 1 67 46 160 671. 60 170 1.2 67 435 CB #3 340 10 CB #2 SICB #2 LANDSCAPING AND BUS SHELTER BY OTHERS 25 672.734 400 0 G 1 1. 150 .20 C .550 671 40 1.2 67 671 .345 Scale: 1:10 BUS 1 G NOTE: ELEVATIONS SHOWN AT BUS 8 ARE TYPICAL FOR BUS 2-7 42 5 0+180 671 .345 67 BUS 2 G 671 .345 2 9 0.9 0 .25 671 .330 165 0 06 0+ 671 .630 671 67 1. 340 71. 6 671.300 BUS 3 67 1 67 .290 1.3 00 0 R1 BUS 4 67 REVERSE GUTTER 0 .35 671 C4 G G 135 120 REVERS E GUTTER BUS 7 1 180 671.2 90 671.3 00 0 300 BUS 8 600 155 67 1. 07 STA N GUT DARD TER (EX I STI NG ) G 40 C 0 R1 FUTURE BUS 9 .73 0 67 25 G G KWL 5755 672.979 G APPROVED SUB-GRADE - EXCAVATE TO DESIGN SUB-GRADE ELEVATION AND OBTAIN APPROVAL FROM THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMEN OF SUB-BASE MATERAILS G O:\0000-0099\029-264\501-Drawings\a_Production_Dwgs\29 264 C 101.dwg 0+120 G 0 R4 C B 0 671.05 G 0 25 670 2 92 0. 7 6 1. 71. R3 0 6 0+100 8 OOP 003 670.690 0 .98 670 BUS L KWL 5756 670.672 N 5551520 47 .8 0 67 99 3 67 240 50 10 0. 67 G 6 260 65 70. 1 77 REVERSE GUTTER 0.6 0.8 9 67 SICB #4 Scale: 1:10 60 0 67 0+200 60 0. 8 67 0+0 STANDARD GUTTER 0+080 27 .7 D 670 6 .66 0 67 95 .323 STAND ARD GUTTE R 671.020 SICB #3 0 40 50 06 .6 670.110 RE GU VER TT SE ER 135 165 R1 0 0+ 66 9 G 150 300 150 7 1 67 G millimeters 0 G 670.820 8 .42 670 600 6 CB #1 668.840 EX C 0.6 9 6 0 .03 669.110 6 20 0 .03 71 67 80 71.0 0 .40 669 . 70 KWL 5754 669.318 SICB #1 C5 0 00 670.7 1. 67 R40 5 64 CB #8 G 0 6 G 0 R1 D 5 R1 G 22 .615 670 0 08 1. 67 0 70.59 5 06 1. 67 670.5 0 03 1. 67 R3 0 585 20 670 .25 0 G REVER SE GUTTE R 0 0 67 0.4 5 20 0 +0 5 100 .66 G 670. 6 SICB #5 N 5551540 G G G 20 .5 70 40 0 67 0 .53 50 G 670.550 0 04 670.150 G 0+ 75 0.2 67 0 240 260 G 6 0 67 REVERSE GUTTER 5 0.2 67 60 C 95 0.5 67 STANDARD GUTTER 670.200 G G G G G 0+ 239 G 0+ Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm N 5551560 CB TYPICAL PAVING SECTION A 0 Scale: 1:10 5 (1:500) 25m A Seal: Rev 0 Date Des Dwn Chk 2016-05-31 FFF CAP Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER RESORT MUNICIPALITY OF WHISTLER WHISTLER GATEWAY LOOP REDEVELOPMENT CIVIL GRADING PLAN Project No. Group 1 2 3 4 5 6 29.264 CIVIL Drawing No. Rev. C 101 7 0 7 E 503160 E 503120 E 503100 E 503080 E 503060 6 0 +0 00 E 503040 5 4 E 503140 3 2 SAVED 2016-05-31 8:56 AM 1 E Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm N 5551560 E N KWL 5751 670.637 0+000 0+ 239 0+020 C R7 BUS PARKED AGAINST RMOW TYPE A CURB 6 .0 0 20 0 04 0 .0 R1 0+ 0+ 0 +0 0 5 2. R1 .00 100 0 22 R23 N 5551540 3 6.2 3 10 .10 5 6.4 06 0 .5 0 0+080 10.00 26.58 0+200 9.70 3 0+0 BC: 0+0 40 50 .0 0 50 R1. R15.00 0+100 0+120 KWL 5756 670.672 N 5551520 EC: 0+207.92 R5 0+ 7.47 D BC: 0+209.79 0 7 KWL 5754 669.318 R1 4.0 millimeters 5 R3.0 C 3.2 7 D R6 C5 0 .0 R6 00 0. R1 .00 2.6 0+140 7. 0 10 R1 50 5 2.1 C 1 .00 . R1 50 6.70 4 3.5 3.00 5 5.3 0 06 0+ R8 R15 .00 50 0 2.0 C4 0 . R1 .0 8 R1 RICON WHEELCHAIR DEVICE DEPLOYED ON PAVEMENT 6.75 C .00 R1 0+180 C 5 N 5551500 6 3. 07 + :0 R6.00 BC: 0 +170 .9 7 KWL 5753 671.480 0 08 0+ R8.00 EC 9.00 EC: 0 +162 0 R9 .0 R6 R9.5 0 B 0+120 9.50 BEG. CURVE COORDINATES END CURVE COORDINATES PI COORDINATES CENTER OF CURVE COORDINATES 85.00 33.95 17.204 0+039.70 0+073.65 N=5551526.19 E=503058.51 N=5551497.21 E=503075.77 N=5551509.96 E=503064.21 N=5551554.33 E=503138.72 C2 12.00 11.65 6.332 0+101.62 0+113.27 N=5551476.50 E=503094.56 N=5551472.68 E=503105.09 N=5551471.81 E=503098.81 N=5551484.57 E=503103.44 C3 12.00 14.81 8.515 0+147.32 0+162.13 N=5551477.34 E=503138.82 N=5551486.85 E=503148.94 N=5551478.50 E=503147.25 N=5551489.22 E=503137.18 C4 200.00 36.95 18.530 0+170.97 0+207.92 N=5551495.51 E=503150.69 N=5551532.20 E=503154.63 N=5551513.67 E=503154.36 N=5551535.13 E=502954.65 C5 21.00 19.35 10.423 0+209.79 0+229.14 N=5551534.07 E=503154.66 N=5551550.92 E=503146.60 N=5551544.49 E=503154.81 N=5551534.38 E=503133.66 C6 16.00 20.77 12.142 0+026.18 0+046.95 N=5551554.05 E=503074.07 N=5551540.95 E=503088.29 N=5551552.90 E=503086.16 N=5551538.13 E=503072.54 C7 15.50 19.12 10.990 0+046.95 0+066.07 N=5551540.95 E=503088.29 N=5551528.37 E=503101.08 N=5551530.13 E=503090.23 N=5551543.68 E=503103.55 C1 .50 END CURVE STATION R12 BEG. CURVE STATION 0 TANGENT LENGTH DELTA .0 R23 CURVE LENGTH RADIUS 6.35 2.75 O:\0000-0099\029-264\501-Drawings\a_Production_Dwgs\29 264 C 102.dwg ALIGNMENT CURVE DATA CURVE # R9.83 6.75 2 3 0+140 13.27 C C R2.57 0 BC 0+ 0 .5 + :0 EC: 0+1 10 0+ 6 1. 10 7.32 2 75 2. B 4 BC: 0+1 25 6. 00 R3. N 5551480 160 .13 KWL 5755 672.979 0 2 (1:250) 10m A A Seal: Rev 0 Date Des Dwn Chk 2016-05-31 FFF CAP Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER RESORT MUNICIPALITY OF WHISTLER WHISTLER GATEWAY LOOP REDEVELOPMENT CIVIL ROAD GEOMETRICS Project No. Group 1 2 3 4 5 6 29.264 CIVIL Drawing No. Rev. C102 7 0 3 2 5 4 6 7 SAVED 2016-05-30 3:47 PM 1 E 674 673 673 PVI STA: 0+119.71 PVI ELEV: 671.072 01% G G ST REET LIG HTIN HTIN G T LIG EXIS EXIS TIN TING STRE E TREE T STOR EXIS TING LIGH TING LE M MA NHO MAIN GAS ING EXIS T ET LI GHT ING STRE ING VILLA EXIS T 669 D GE G A millimeters TE B 670 EXIS TING STOR EXIS M MA TING IN STRE ET LI GHT ING 671 84.25 @ 0.76% OUL EVAR D 100 671 668 0+040 50 672 10.33 @ 2. EXIS TING S TIE-IN TO EXISTING PVI STA: 0+035.46 PVI ELEV: 670.433 672 CAR PARKING PVI STA: 0+130.03 PVI ELEV: 671.280 674 \CROSSWALK Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm E 0+060 0+080 0+100 670 669 D 668 0+135 0+120 BUS LOOP PROFILE 0 10 HORIZONTAL SCALE 1:250, VERTICAL SCALE 1:50 CENTERLINE BUS LOOP STA 0+196.32 LOW PT STA: 0+218.48 LOW PT ELEV: 669.82 PVI STA: 0+214.00 PVI ELEV: 669.70 AD: 9.71% K: 1.55 LVC: 15.00 EVCS: 0+221.50 EVCE: 669.85 ET LI G 0@ EVAR D TIE-IN TO EXISTING 10. 5 673 672 BVCS: 0+206.50 BVCE: 670.28 BVCS: 0+184.00 BVCE: 671.37 674 G HTIN MAIN GAS -7.7 5% STRE TING 3.00 @ 3.20% 671 670 BOU L EXIS T ING EXIS EXIS 675 LVC: 12.00 EVCS: 0+181.00 EVCE: 671.27 BVCS: 0+169.00 BVCE: 671.37 PROPOSED CROSSWALK AIN .81% TING TING EXIS @ -4 ELEC TRIC AL M RICA L ELEC T EXIS STA 0+157.29 Ex. HYDRO/TEL STA 0+154.00 16.00 MAIN M MA IN STOR TING EXIS TING T LIG TREE STA 0+166.66 EVCS: 0+153.00 EVCE: 672.14 EVCS: 0+125.00 EVCE: 672.69 AIN WAT ER M G HTIN IN AL M A EXIS EXIS T ELEC TING TRIC ELEC HIGH PT STA: 0+187.51 HIGH PT ELEV: 671.43 PVI STA: 0+190.00 PVI ELEV: 671.56 AD: -10.96% K: 1.10 LOW PT STA: 0+176.20 LOW PT ELEV: 671.20 PVI STA: 0+175.00 PVI ELEV: 671.08 AD: 8.01% K: 1.50 LVC: 12.00 13.00 @ -0.92% EXIS T ING ING S TRIC AIN AL M AIN ER M WAT TARY SANI ING EXIS T TING EXIS SANI T TING EXIS STRE TING STOR MAIN ARY ING ET LI GHT CE B 669 VILLA GE G ATE TING EXIS 669 3.98% C EXIS 670 WAT B ER S ERVI 1.58% M MA IN 671 TING MAIN TIE-IN MEDIAN GUTTER TO EXISTING GUTTER TIE-IN ASPHALT EAST OF MEDIAN TO EXISTING @ 15.00 EXIS 672 EVCS: 0+085.00 EVCE: 671.71 673 PROPOSED CROSSWALK BVCS: 0+045.00 BVCE: 670.60 674 BVCS: 0+100.00 BVCE: 672.30 LOW PT STA: 0+045 LOW PT ELEV: 670.60 PVI STA: 0+065.00 PVI ELEV: 670.91 AD: 2.40% K: 16.65 LVC: 40.00 675 PROPOSED CROSSWALK C 676 BVCS: 0+138.00 BVCE: 672.57 676 HIGH PT STA: 0+138 HIGH PT ELEV: 672.57 PVI STA: 0+145.50 PVI ELEV: 672.50 AD: -3.89% K: 3.85 LVC: 15.00 EVCS: 0+196.00 EVCE: 671.10 HIGH PT STA: 0+120.32 HIGH PT ELEV: 672.71 PVI STA: 0+112.50 PVI ELEV: 672.80 AD: -4.90% K: 5.10 LVC: 25.00 668 0+040 0+060 0+080 0+100 0+120 0+140 0+160 0+180 0+200 668 0+230 0+220 GATE WAY DRIVE PROFILE O:\0000-0099\029-264\501-Drawings\a_Production_Dwgs\29 264 C 201.dwg HORIZONTAL SCALE 1:250, VERTICAL SCALE 1:50 A Seal: Rev 0 Date Des Dwn Chk 2016-05-31 FFF CAP Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER Group 2 3 4 5 6 2 0 0.5 (H 1:250) 10m (V 1:50) 2m A RESORT MUNICIPALITY OF WHISTLER WHISTLER GATEWAY LOOP REDEVELOPMENT CIVIL GATE WAY LOOP & BUS LOOP PROFILE Project No. 1 0 29.264 CIVIL Drawing No. Rev. C201 7 0 SAVED 2016-05-30 3:44 PM 1 3 2 5 4 6 GATE WAY LOOP 7 BUS LOOP 674 674 STA. 0+090 674 674 E E Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm 672 672 672 670.603 670.590 670.520 670.310 670 670 -20 -10 0 670 670 10 LANDSCAPING SECTION - GATE WAY DR STA 0+090 100 Horizontal Scale: 1:100 Vertical Scale: 1:50 668 -10 STA. 0+130 676 millimeters 672 0 10 676 668 30 20 SECTION - BUS LOOP STA 0+046.95 Horizontal Scale: 1:100 Vertical Scale: 1:50 D D Busloop_CL STA. 0+070 674 50 674 674 6.75 2.75 672.700 10 -10 0 672 672.642 672.591 672 -20 672.734 0 672 10 671.300 SECTION - GATE WAY DR STA 0+130 Horizontal Scale: 1:100 Vertical Scale: 1:50 670.817 670.695 STA. 0+170 674 674 670 C C 4.50 4.50 672 672 668 -20 -10 BUS LOOP 0 10 20 SECTION - BUS LOOP STA 0+070 Horizontal Scale: 1:100 Vertical Scale: 1:50 670 -20 -10 0 670 10 SECTION - GATE WAY DR STA 0+170 Horizontal Scale: 1:100 Vertical Scale: 1:50 STA. 0+210 672 672 671.065 B B 670.110 670.050 670 670 669.825 O:\0000-0099\029-264\501-Drawings\a_Production_Dwgs\29 264 C 301.dwg LANDSCAPING 668 -20 -10 0 668 10 SECTION - GATE WAY DR STA 0+170 Horizontal Scale: 1:100 Vertical Scale: 1:50 A 0 1 (H 1:100) 4m 0 0.5 (V 1:50) 2m A GATE WAY DRIVE Seal: Rev 0 Date Des Dwn Chk 2016-05-31 FFF CAP Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER RESORT MUNICIPALITY OF WHISTLER WHISTLER GATEWAY LOOP REDEVELOPMENT CIVIL SECTIONS Project No. Group 1 2 3 4 5 6 29.264 CIVIL Drawing No. Rev. C301 7 0 6 E 503140 E 503120 E 503100 E 503080 E 503060 E 503040 5 4 7 E 503160 3 2 SAVED 2016-05-31 8:57 AM 1 N E E Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm N 5551560 100 KWL 5751 670.637 N 5551540 millimeters KWL 5754 669.318 D D 50 R-001.gif KWL 5756 670.672 0 10 N 5551520 C C N 5551500 KWL 5753 671.480 N 5551480 O:\0000-0099\029-264\501-Drawings\a_Production_Dwgs\29 264 C 103.dwg B B KWL 5755 672.979 0 2 (1:250) 10m A A Seal: Rev 0 Date Des Dwn Chk 2016-05-31 FFF CAP Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER RESORT MUNICIPALITY OF WHISTLER WHISTLER GATEWAY LOOP REDEVELOPMENT CIVIL ROAD PAINTING AND SIGNAGE Project No. Group 1 2 3 4 5 6 29.264 CIVIL Drawing No. Rev. C103 7 0 3 2 5 4 6 7 G SAVED 2016-05-31 10:22 AM 1 SL 0+080 SL SL G SL SL SL SL E w SL E 0+100 N SL Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm G INSTALL NEW STORMWATER TREATMENT SYSTEM VORTECHS MODEL 1000 OR APPROVED EQUIVALENT w SL SL w w w G d SL s w SL w w SANITARY MH S1 w E E G E SL d s w SL STORM MAIN AND "OVER-BUILD' NEW SL s E s SL d 100 SL G STOP TO BE EXCAVATED AND RELOCATED AS SHOWN s w SANITARY SERVICE CONNECTION SL SL s SL STORM DRAIN s d millimeters G SL w D G SL E D s s STORM DRAIN MH D2 INSTALL CLEAN-OUT ON PERFORATED PIPE C/W BROOKS 37GBOX AND LID MARKED "STORM" D SL s 50 SL SL D d w SL D s C/W BROOKS 37 BOX & LID MARKED "STORM" NOTE: REFER TO ELECTRICAL FOR HEAT TRACE CONNECTION DETAILS TO IC D s D D w E G d D SL SANITARY SERVICE C/W 2"x4" MARKER POST w D SL s COPPER WATER SERVICE C/W CURB STOP AND SERVICE BOX. NOTE: SET LID ON DAIGLE BOX 150mm BELOW FINISH GRADE G s D 10 D d E D d CONNECTIONS TO COLUMN PEDESTALS. SEE STRUCTURAL AND ARCHITECTURAL DRAIN ROCK AND NON-WOVEN FILTER CLOTH E G SL d D D SL d INSTALL SANITARY SERVICE INSPECTION CHAMBER IC1 D 0 D SL G SL D d G D d D E d d D d d C SL d C d G D d SL d INSTALL CLEAN-OUT(S) AT END OF PERFORATED PIPE C/W BROOKS 37 BOX AND G LID MARKED "STORM" SL D d D D d d d d D SL E INSTALL CLEAN-OUT AT END G d BROOKS 37 BOX AND LID MARKED "STORM" d SL D INSTALL CLEAN-OUT AT END OF 150mm DRAIN LINE C/W BROOKS 37 BOX AND LID MARKED "STORM" SL d CONNECTION TO TO PERFORATED FRENCH DRAIN BEHIND LANDSCAPE WALL. STORM DRAIN E S S S S S S S S D S S S S S D S S SL S SL D D S S S E D SL SANITARY, WATER AND DRAIN SERVICING PLAN O:\0000-0099\029-264\501-Drawings\a_Production_Dwgs\29 264 C 104.dwg Scale: 1:100 B B A A Seal: Rev 0 Date Des Dwn Chk 2016-05-31 FFF CAP Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER RESORT MUNICIPALITY OF WHISTLER WHISTLER GATEWAY LOOP REDEVELOPMENT CIVIL SANITARY & WATER SERVICES Project No. Group 1 2 3 4 5 6 29.264 CIVIL Drawing No. Rev. C 104 7 0 3 2 5 4 JB29 SL SL SL SL TO JB 8, 9, 24 SL SL POLE 4 SL SL SL JB28 SL SL SL JB16 POLE 6 SL SL SL POLE 5 E SL SL SL Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm SL SL SL JB40 NOTE 4, 6 AND 11 SL JB14 JB41 NOTE 1 AND 2 SL SL NEW JB7 NOTE 3 SL SL15 SL SL1 C33 SL SL SL POLE 7 EXSISTING JB7 TO BE REMOVED SL14 SL SL SL SL INUKSUK DIRECTIONAL DRILLING REQUIRED N SL SL TO JB 1, 2, 30, 31, 32 POLE 1, 2, 21 E 7 TO JB 13, 22, 23, 33, 34 POLE 8, 9, 10, 22, 23, 24, 25, 29 POLE 3 EXISTING LIGHTING SL SL C71 SL JB6 SL C18 C34, T4 SL SL C52 SL JB4 POLE 19 TO BE RELOCATED AND RENAMED SL14 100 C63 SL24 SYMBOLE LEGEND SL POLE 17 SHALL BE RELOCATED AND RENAMED SL13 SL16 C17A, C6, C7, C8 SL2 millimeters 6 SL SAVED 2016-05-31 10:04 AM 1 GROUND ELECTRODE BOX SL13 SL18 GROUND ROD SL EXISTING JB19 SHALL BE REMOVED EXISTING LIGHTING DISTRIBUTION KIOSK SHALL BE REMOVED 50 EXISTING STREET LIGHT NEW STREET LIGHT SL REFER TO A3.01 FOR POWER RECEPTACLE IN BUS SHELTER ROOF Scale: N.T.S. HEAT TRACING C1 SL12 0 WAY FINDING KIOSK SL SL 10 HEAT TRACE GROUND ELECTRODE DETAIL SL EXSISTING JB20 SHALL BE REMOVED SL17 JB27 #2/0 AWG. CU. GROUND ROD 3M LONG C2, T2 NOTE 3 NEW CONDUIT C103, REFEED EXISTING SL18 FROM NEW JB21 POLE 18 SHALL BE RELOCATED AND RENAMED SL12 EXISTING JB34 SHALL BE REMOVED SL3 EXISTING CONDUIT SL EXISTING BC HYDRO BOX SHALL BE REMOVED C9 D #2/0 AWG. CU. C83 SL D MAIN SERVICE BREAKER TO SECOND GROUND ROD C141, C142 RECEPTACLE C19 GROUND RODS C10, T3 SL NEW LIGHTING DISTRIBUTION KIOSK JB47 NOTE 1 C11B NOTE 2 C4 SL4 POLE 15 JB49 NOTE 1 LED STRIP LIGHTS JB48 NOTE 1 SL19 C105, REFEED EXISTING SL19 FROM NEW JB21 SL C3 C C130, REFEED EXISTING SL15 FROM NEW JB21 C11C NOTE 2 JB46 C11 NOTE 1 C11A NOTE 2 NOTE 2 SL5 300 C3O JB44 NOTE 1 S0 POLE 28 SHALL BE RELOCATED AND RENAMED SL11 NOTE 9 SL SL25 C131 E E E E SL E E E C54 E E E E SL CXX CYY CZZ E SCREENED EARTH OR SAND 75 E E IMPORTED GRANULAR BACKFILL TO MMCD STANDARDS COMPACTED TO 95% MPD 75 C21 600 MIN SL C5 C132 JB43 NOTE 1 SL EXSISTING JB10 SHALL BE REMOVED T1 E C104 SL11 SL SL C12 C WARNING TAPE GRADE SL10 E 75 SL SL NEW JB10 NOTE 1 SL23 E 50 50 75 SL TYPICAL TRENCH SECTION SL20 SL6 E C36 Scale: N.T.S. E E C95 PROVIDE PULL STRING IN ALL CONDUITS B ROADBED JB25 SL9 SL SL8 SL SL SL SL E SL SL SL21 SL DRAIN ROCK SL C129 E C123 SL B C144 JB50 NOTE 1 SL7 E TRENCHING ENDS HERE, COORDINATE WITH RMOW FOR TELECOMUNICATION CONNECTION POINT LOCATED IN UNDERGROUND PARKADE, DIRECTIONAL DRILLING REQUIRED. SL22 150 MIN. E JB11 E SL SL NOTES: 1. PROVIDE TYPE#37 WATER METER BOX FROM LANGLEY CONCRETE GROUP AND NEMA 4X JUNCTION BOX FOR ELECTRICAL TERMINATION AS REQUIRED. 2. CABLES TO BE PULLED IN THE FUTURE. PROVIDE PULL STRING IN ALL CONDUITS 3. C2, T2 ROUTED INSIDE THE COLUMN B2 FOR BUS SHELTER ROOF ACCESS. 4. PROVIDE TEMPORARY POWER FOR ALL VILLAGE GATE BOULEVARD STREET LIGHTING DURING CONSTRUCTION. 5. ALL UNUSED CONDUIT SHALL BE REMOVED. 6. PROVIDE ARMTEC T266 SERVICE BOX AND NEMA 4X JUNCTION BOX FOR ELECTRICAL TERMINATION SIZED AS REQUIRED. 7. ALL EQUIPMENT REMOVED SHALL BE PROPERLY DISPOSED BY THE CONTRACTOR. 8. REUSE POLE BASE IF IN GOOD CONDITION. 9. COORDINATE SERVICE CONNECTION WITH BC HYDRO. 10. RELOCATE EXISTING POLE 13 AND RENAME SL21 AS PART OF THE PLANTER WALL RELOCATION. 11. REPLACE EXISTING JB17 WITH NEW JB 40. SL C114 SL SL JB26 NOTE 10 E E E CONDUIT UNDERGROUND PARKADE E IN GROUND JUNCTION BOX DETAIL (TYP.) E N.T.S. E \\192.168.200.200\Nelson\Projects\0000-0999\0000-0099\0029 - RMOW\264 - Gateway Loop Project\501-Drawings\a-Production Drawings\E-101.dwg SL E SL E ROAD SURFACE 0 2 (1:250) 10m A A Seal: Rev Date 0 2016-05-31 Des Dwn Chk SG Description of Revision Rev Date Des Dwn Chk Description of Revision RESORT MUNICIPALITY OF WHISTLER GATEWAY LOOP PROJECT ELECTRICAL SITE PLAN SG AvdH ISSUED FOR TENDER Project No. Group 1 2 3 4 5 6 29.264 ELECTRICAL Drawing No. Rev. E101 7 0 3 2 SAVED 2016-05-31 10:16 AM 1 5 4 6 PANEL A 125 AMP MAIN LUGS SURFACE MOUNT BC HYDRO S0, CONDUCTOR BY BCH, 103C PROVIDE PULLSTRING DISTRIBUTION KIOSK E Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm 500 15ASP 1 2 15ASP 200 CROSSWALK FLASHERS LIGHT IN DISTRIBUTION KIOSK 100 15ASP 3 4 15ASP 1000 FIREHALL FLASHERS HEATER IN DISTRIBUTION KIOSK 500 15ASP 5 6 15ASP 1000 FIREHALL FLASHERS HEATER IN DISTRIBUTION KIOSK 500 15ASP 7 8 15ASP 200 RECEPTACLES BUS SHELTER ROOF AUXILIARY LIGHTING SL 7, 8, 9 50 15ASP 9 10 15ASP 1000 HEAT TRACE E2 & E3 SEASONAL LIGHTING 100 15ASP 11 12 15ASP 250 RECEPTACLES BUS SHELTER LANDSCAPE 13 14 15ASP 250 RECEPTACLES LANDSCAPE 15 16 15ASP 250 RECEPTACLE WAY FINDING KIOSK 17 18 19 20 21 22 23 24 S1, 3#400MCM, 78C #2/0 INSTRUMENT TRANSFORMER ENCLOSURE METER BASE GROUNDING PAD 120/208 VOLTS, 3 PHASE, 4W 24 CIRCUIT RECEPTACLE IN DISTRIBUTION KIOSK CB1 400A 3P #2/0 Cu E S2, 3#400MCM, 78C PANEL B 125 AMP MAIN LUGS SURFACE MOUNT 100 SPLITTER CB2 60A 3P millimeters 7 CB3 60A 3P CB4 60A 3P S4, 3#8, 35C D CB5 60A 3P S5, 3#8, 35C CB6 100A 3P S6, 3#4, 53C POLES 5, 6, 9 , 21, 25 1620 30ASP 1 2 15ASP 500 CAR PARK LIGHTING POLES 2, 4, 7, 10, 23 1440 30ASP 3 4 15ASP 500 CAR PARK LIGHTING POLES 1, 3, 8, 22, 24, 29 1440 30ASP 5 6 15ASP 250 BUS SHELTER COLUMNS LIGHTING SL 6, 7, 17, 18, 21, 22 475 20ASP 7 8 15ASP 250 LANDSCAPE LIGHTING SL 5, 9, 11, 19, 25, POLE 15 490 20ASP 9 10 15ASP 250 WAYFINDING KIOSK LIGHTING SL 4, 8, 10, 20, 23, 24 470 20ASP 11 12 15ASP 250 BUS SHELTER LANDSCAPE LIGHTING SL 3, 13, 15 70 15ASP 13 14 SL 2, 12, 16 70 15ASP 15 16 SL 1, 14 35 15ASP 17 18 19 20 21 22 23 24 CONTACTOR/TIMER ENCLOSURE S3, 3#8, 35C TIMER T 120/208 VOLTS, 3 PHASE, 4W 24 CIRCUIT D 50 FUTURE WASHROOM S7, 3#8 35C PANEL B STREETLIGHTS PANEL C STREETLIGHT RECEPTACLES PANEL C 125 AMP MAIN LUGS SURFACE MOUNT S9, 3#8, 35C PANEL D TREE-LIGHTING 0 10 PANEL A UNSWITCHED LOADS S8, 3#8 35C SINGLE LINE DIAGRAM SCALE: N.T.S RECEPTACLES ON POLES 5, 6, 9 , 21, 25 250 30ASP 1 2 RECEPTACLES ON POLES 2, 4, 7, 10, 23 250 30ASP 3 4 RECEPTACLES ON POLES 1, 3, 8, 22, 24, 29 300 30ASP 5 6 RECEPTACLES ON SL 6, 7, 17, 18, 21, 22 350 20ASP 7 8 RECEPTACLES ON SL 5, 9, 11, 19, 25, POLE 15 350 20ASP 9 10 RECEPTACLES ON SL 4, 8, 10, 20, 23, 24 300 20ASP 11 12 14 RECEPTACLES ON SL 3, 13, 15 250 20ASP 13 RECEPTACLES ON SL 2, 12, 16 250 20ASP 15 16 RECEPTACLES ON SL 1, 14 250 20ASP 17 18 19 20 21 22 23 24 120/208 VOLTS, 3 PHASE, 4W 24 CIRCUIT C C PANEL D 200 AMP MAIN LUGS SURFACE MOUNT SPLITTER PANEL B, C OR D CONTACTOR/TIMER ENCLOSURE A B C N A B C BY OTHERS N CB3, 4 OR 5 C WI-FI NODE COLUMN B2 \\192.168.200.200\Nelson\Projects\0000-0999\0000-0099\0029 - RMOW\264 - Gateway Loop Project\501-Drawings\a-Production Drawings\E-102.dwg DISTRIBUTION KIOSK TO RMOW COMMUNICATION IN UNDERGROUND PARKADE T1, 78C OWNER WILL INSTALL CABLE T2, 53C WAYFINDING KIOSK 10A O B H A C HAND INUKSUK LIGHTING CONTROL CONTACTOR OFF T AUTO JUNCTION BOX - JB1 500 15ASP 1 2 15ASP 500 JUNCTION BOX - JB7 JUNCTION BOX - JB1 500 15ASP 3 4 15ASP 500 JUNCTION BOX - JB7 JUNCTION BOX - JB1 500 15ASP 5 6 15ASP 500 SPARE JUNCTION BOX - JB1 500 15ASP 7 8 15ASP 500 JUNCTION BOX - JB8 JUNCTION BOX - JB1 500 15ASP 9 10 15ASP 500 JUNCTION BOX - JB8 JUNCTION BOX - JB1 500 15ASP 11 12 15ASP 500 JUNCTION BOX - JB8 JUNCTION BOX - JB2 500 15ASP 13 14 15ASP 500 JUNCTION BOX - JB9 JUNCTION BOX - JB2 500 15ASP 15 16 15ASP 500 JUNCTION BOX - JB9 JUNCTION BOX - JB2 500 15ASP 17 18 15ASP 500 JUNCTION BOX - JB9 JUNCTION BOX - JB2 500 15ASP 19 20 15ASP 500 JUNCTION BOX - JB10 JUNCTION BOX - JB2 500 15ASP 21 22 15ASP 500 JUNCTION BOX - JB10 JUNCTION BOX - JB2 500 15ASP 23 24 15ASP 500 JUNCTION BOX - JB10 JUNCTION BOX - JB3 500 15ASP 25 26 15ASP 500 JUNCTION BOX - JB11 JUNCTION BOX - JB3 500 15ASP 27 28 15ASP 500 JUNCTION BOX - JB11 - 15ASP 29 30 15ASP 500 JUNCTION BOX - JB11 JUNCTION BOX - JB4 500 15ASP 31 32 15ASP 500 JUNCTION BOX - JB11 JUNCTION BOX - JB4 500 15ASP 33 34 15ASP 500 JUNCTION BOX - JB11 JUNCTION BOX - JB4 500 15ASP 35 36 15ASP 500 JUNCTION BOX - JB11 JUNCTION BOX - JB4 500 15ASP 37 38 15ASP 500 JUNCTION BOX - JB12 JUNCTION BOX - JB4 500 15ASP 39 40 15ASP 500 JUNCTION BOX - JB12 JUNCTION BOX - JB4 500 15ASP 41 42 15ASP 500 JUNCTION BOX - JB12 JUNCTION BOX - JB5 500 15ASP 43 44 15ASP - SPARE JUNCTION BOX - JB5 500 15ASP 45 46 15ASP - SPARE - 15ASP 47 48 15ASP - SPARE JUNCTION BOX - JB6 500 15ASP 49 50 JUNCTION BOX - JB6 500 15ASP 51 52 - 15ASP 53 54 55 56 57 58 59 60 SPARE T3, 53C T4, 53C SPARE T TIMER: PANEL B, C AND D 120/208 VOLTS, 3 PHASE, 4W 60 CIRCUIT SPARE TIMING CONTROL TYP. COMMUNICATION BLOCK DIAGRAM PANEL SCHEDULE N.T.S. N.T.S. N.T.S. B A A Seal: Rev Date 0 2016-05-31 Des Dwn Chk SG Description of Revision Rev Date Des Dwn Chk Description of Revision RESORT MUNICIPALITY OF WHISTLER GATEWAY LOOP PROJECT ELECTRICAL SINGLE LINE DIAGRAM SG AvdH ISSUED FOR TENDER Project No. Group 1 2 3 4 5 6 29.264 ELECTRICAL Drawing No. Rev. E102 7 0 SAVED 2016-05-31 10:18 AM 1 5 4 6 7 DISTRIBUTION KIOSK PANEL A PANEL B PANEL C HEAT TRACE CONTROL Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm E C1, 8#12, 35C SL3 B13 B11 C 100 C2, 6#12, 53C C7, 4#6, 53C C6, 4#6, 53C C5, 16#8, 53C JB10 C141, 53C C17A, 2#12, 17#8, 19#6, 78C C8, 3#8, 8#6, 53C JB40 C3, 4#12, 53C C142, 78C JB41 LANDSCAPE C11 C15 B9 C14, 4#6, 53C JB16 C13, 16#8, 53C JB25 C15, 4#4, 53C JB14 C16, 8#6, 3#8, 53C JB28 JB PROVISION FOR FUTURE ELECTRICAL CAR CHARGING STATION C17,19#6 + 17#8 + 2#12, 78C PS PS B C21, 10#10, 35C C22, 8#8 JB11 C23, 4#8 JB12 B1 C17 C26, 4#6 POLE #6 C25, 4#4 C24, 4#6 POLE #5 C1 C27, 4#4 B1 JB24 C28, 8#6 C29, 3#8 JB7 JB5 C31, 3#6 + 3#8 + 2#12 C32, 3#8 JB6 C1 C30, 16#6 + 11#8 + 2#12, 78mm DB2 D C33, 8#12, 35C SL15 JB47 JB46 C38, 4#6 POLE #4 B3 C13 C40, 4#6 POLE #7 C39, 4#4 C3 C41, 4#4 B3 JB8 C50, 4#6 C51, 4#6 JB9 JB29 C3 C11A, 2-53C 50 JB C9 A B13 C3O, 4#12, JB44 53C JB43 C12, 10#10, 35C SL5 C B17 C19, 2#12, 53C C10, 4#12, 53C C11, 2-53C B C9, 8#12, 35C SL2 B15 T E SL4 C13 IRRIGATION CONTROL PANEL PANEL D C4, 10#10, 35C C18, 8#12, 35C SL1 millimeters 3 2 B C3A,VENDOR CABLE,21C C3B,VENDOR CABLE,21C C3C,VENDOR CABLE,21C C3D,VENDOR CABLE,21C C3E,VENDOR CABLE,21C C3H,VENDOR CABLE,21C C3I,VENDOR CABLE,21C C3J,VENDOR CABLE,21C C3K,VENDOR CABLE,21C C3L,VENDOR CABLE,21C C3F, 2#12,21C C3M, 2#12,21C C3G, 2#12,21C C52, 8#12, 35C SL16 B15 C56, 4#6 POLE #3 B5 C15 C58, 4#6 JB13 C57, 4#4 C59, 4#4 JB3 10 C62, 8#8 JB4 B8 D C65, 4#8 JB30 0 C11C, 2-53C B8 D B8 D C60, 16#6, 78mm DB2 C67, 4#6 POLE #8 C66, 4#4 B5 C17 POLE #22 B5 C5 B8 D B8 D C69, 4#8 C68, 4#4 B8 D B8 D JB48 JB49 C63, 8#12, 35C SL14 B17 C3N, 2#12,21C C5 C11B, 2-53C A C61, 3#8, 2#12 D C70, 4#4 JB32 B8 D B8 D C5 B8 D B C71, 8#12, 35C SL13 B13 C C73, 2#8 POLE #21 B1 C13 C75, 3#8 C77, 4#8 C76, 3#4 JB22 C74, 2#4 POLE #2 C1 B3 C79, 4#8 C78, 3#4 C80, 4#4 JB33 JB1 C81, 8#6 C82, 8#6 JB2 C3 C B C83, 8#12, 35C SL12 B15 C87, 2#8 C86, 2#4 POLE #9 C85, 2#8 POLE #1 B5 C15 C5 C89, 3#8 C88, 2#4 JB23 B1 C91, 2#8 C90, 2#4 JB34 C93, 2#8 C92, 3#4 POLE #23 B3 C1 C94, 2#4 C3 BUS SHELTER ROOF C2T,2#12, TECK B BSJB1 C101, 4#8 POLE #10 JB26 JUNCTION BOX COLUMN E2 WAY FINDING KIOSK JB \\192.168.200.200\Nelson\Projects\0000-0999\0000-0099\0029 - RMOW\264 - Gateway Loop Project\501-Drawings\a-Production Drawings\E-103.dwg C109, 4#8 SL23 B11 C110, 4#6 C11 C111, 4#8 SL22 B7 C112, 4#6 C7 C7 JUNCTION BOX SL25 B B9 E C A9 B7 SL8 A C A9 B11 SL9 A9 B11 C11 B7 C126, 2#8 C116, 2#8 COLUMN E3 C115, 2#8 C10B, 2#12, 21C POLE #25 B1 B5 D POLE #29 C11 C B11 C127, 2#6 C129, 6#12, 35C C9 C C108, 4#6 B7 PS PS A11 F A11 F C2X,VENDOR CABLE,21C C2Y,VENDOR CABLE,21C A11 F B6 D C2L, 2#12, 21C NOTE 3 B6 D C119, 4#6 A11 F C2V,VENDOR CABLE,21C C2W,VENDOR CABLE,21C C2K, 2#12, 21C B6 D C11 C2M,VENDOR CABLE,21C C2N,VENDOR CABLE,21C C2O,VENDOR CABLE,21C B B6 D C118, 4#8 SL21 PS2 C2Q,2#12,21C C2F, 2#12, 21C C9 B9 PS C2G,VENDOR CABLE,21C C2H,VENDOR CABLE,21C C2I,VENDOR CABLE,21C C2J,VENDOR CABLE,21C B6 D NOTE 3 B6 D B6 D NOTE 3 B6 D SL11 A B9 PS C2A,VENDOR CABLE,21C C2B,VENDOR CABLE,21C C2C,VENDOR CABLE,21C C2D,VENDOR CABLE,21C C2E,VENDOR CABLE,21C C1 SL10 C107, 4#6 SL20 PS1 C2U,2#12, TECK C117, 2#4 C54, 4#12, 35C C132, 8#12, 35C C125, 2#6 SL17 C10A, VENDOR CABLE, 21C B10 B11 BSJB2 PS JB A C123, 8#12, 35C C11 E E C124, 2#8 SL24 C5 C36, 6#12, 35C C131, 8#12, 35C C9 JB27 B5 PS C7 B7 POLE #24 C3 C102, 3#4 C2S, 4#12, BSJB3 27C JB C95, 8#12, 35C C114, 10#12, 35C SL6 SL7 B3 C2R, 4#12, 27C B6 D B6 D B6 D C7 B6 D C144, 35C B6 D JB50 C7 C104, 8#12, 53C JB21 C105, 4#12, 35C C103, 4#12, 35C SL18 B7 C130, 4#12, 35C SL19 C7 NOTES: 1. REFER TO SPECIFICATIONS FOR STREET LIGHT TYPE 2. JB SHALL BE NEMA 4X 3. BUS SHELTER ROOF RECEPTACLES ARE TIMER CONTROLLED POLE #15 B9 C9 B9 C9 A A Seal: Rev Date 0 2016-05-31 Des Dwn Chk SG Description of Revision Rev Date Des Dwn Chk Description of Revision SG AvdH ISSUED FOR TENDER RESORT MUNICIPALITY OF WHISTLER GATEWAY LOOP PROJECT ELECTRICAL LIGHTING AND RECEPT. WIRING DIAGRAM Project No. Group 1 2 3 4 5 6 29.264 ELECTRICAL Drawing No. Rev. E103 7 0 3 2 5 4 6 7 SAVED 2016-05-31 9:59 AM 1 E Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm E 2438H x 2286W x 1066D APPROX. PART NUM. DDSA9610842 100 millimeters SPLITTER PULL BOX 610 x 1220 x 305 (H x W x D) D CB1 IRRIGATION CONTROL PANEL D CONTACTORS / TIMERS ENCLOSURE CB2 CB3 50 UTILITY METER DISCONNECT SWITCH 0 10 CB5 HEAT TRACE CONTROL PROVIDE CIRCUIT BREAKER(S) IN PANEL A & APPROPRIATE CONDUCTORS TO POWER IRRIGATION CONTROL PANEL. UPDATE PANEL A SCHEDULE. WIREWAY 1220 x 457 x 305 (H x W x D) CB4 1500 MIN BCH INSTRUMENT TRANSFORMER 460 x 1065 x 405 (H x W x D) PANEL A PANEL B FASTEN KIOSK TO CONCRETE PAD USING CONCRETE ANCHORS CONTRACTOR SHALL PROPERLY LOCATE CONDUIT PENETRATIONS THROUGH KIOSK PAD PULL BOX S0 PULL BOX \\192.168.200.200\Nelson\Projects\0000-0999\0000-0099\0029 - RMOW\264 - Gateway Loop Project\501-Drawings\a-Production Drawings\E-104.dwg KIOSK CONCRETE PAD B PANEL D PANEL C C 600 MIN C SPACE FOR COMMUNICATION EQUIPMENT KIOSK CONCRETE PAD KIOSK LAYOUT FRONT SIDE KIOSK LAYOUT BACK SIDE SCALE: 1:10 SCALE: 1:10 0 (1:10) 0.1 B 0.5m A A Seal: Rev Date 0 2016-05-31 Des Dwn Chk SG Description of Revision Rev Date Des Dwn Chk Description of Revision RESORT MUNICIPALITY OF WHISTLER GATEWAY LOOP PROJECT ELECTRICAL KIOSK LAYOUT SG AvdH ISSUED FOR TENDER Project No. Group 1 2 3 4 5 6 29.264 ELECTRICAL Drawing No. Rev. E104 7 0 3 2 5 4 6 7 SAVED 2016-05-31 10:19 AM 1 E Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm E 120V POWER/RECEPTACLE POWER STRIPLIGHT/JUMPER WIRE COMMUNICATION C2, T2 ROUTED INSIDE COLUMN D2 100 SEASONAL LIGHTING millimeters STRUCTURAL ROOF SUPPORT COLUMNS D PS1 C2V C2W 50 C2B D C2T C2D 10 C2C T2 BSJB1 0 C2 C2U C2K C2I C2A C2E C2H BSJB2 C2Q RECEPTACLE C2N C2R C2F C WIFI NODE BY OTHERS C BSJB3 C2J C2G C2O C2S C2M REFER TO E106 FOR TYPICAL BSJBX DETAIL C2X C2P C2L PS2 \\192.168.200.200\Nelson\Projects\0000-0999\0000-0099\0029 - RMOW\264 - Gateway Loop Project\501-Drawings\a-Production Drawings\E-105.dwg C2Y B B BUS SHELTER ELECTRICAL DISTRIBUTION N.T.S. A A Seal: Rev 0 Date Des Dwn Chk Description of Revision Rev Date Des Dwn Chk Description of Revision 2016-05-31 JvdH JvdH AvdH ISSUED FOR TENDER RESORT MUNICIPALITY OF WHISTLER GATEWAY LOOP PROJECT ELECTRICAL BUS SHELTER ELECTRICAL DISTRIBUTION Project No. Group 1 2 3 4 5 6 29.264 ELECTRICAL Drawing No. Rev. E105 7 0 3 2 SAVED 2016-05-31 10:12 AM 1 5 4 TO JB TO JB TO JB 6 7 TO JB E Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm E NOTES: 1. INSTALL STRIPLIGHTING UNDERNEATH SEAT OVERHANG FOR BENCHES, AND UNDERNEATH CURB OVERHANG FOR STONE FACED WALLS. 2. INSTALL RECEPTACLES AT BENCH LOCATIONS. INSTALL STRIPLIGHTING UNDERNEATH OVERHANG 100 PLAN WOOD SEAT millimeters SPACE CLIPS EVERY 45cm TYP. CONCRETE BASE D D 50 PROVIDE WATERPROOF FLIP-CAP COVER (TYP) ALLOW SPACE TO HIDE CONNECTION UNDERNEATH OVERHANG (TYP) RECEPTACLE LOCATION (TYP) ELEVATION BENCH/CURB LIGHTING DETAIL 0 10 N.T.S. TYPE 37 SERVICE BOX REFER TO CIVIL DRAWINGS C GRADE C NOTE: 1. NUMBER OF STRIPLIGHTS VARIES PER JB. 2. PROVIDE VARIO JUMPERS AND VARIO LEAD CONNECTORS AS REQUIRED. 3. PROVIDE LARGER JUNCTION BOX AND 320W POWER SUPPLY FOR JB43 AND JB44. REFER TO SPECIFICATION NEMA 4X JB PROVIDE LIQUID TIGHT CONNECTORS 24V/120 W POWER SUPPLY +1 +2 TO STRIPLIGHT -1 TO STRIPLIGHT TO STRIPLIGHT -2 CONNECT TO NEXT JB AS REQUIRED -1 B +1 +1 +1 +1 +1 +2 +2 +2 +2 +2 -1 -1 -1 -1 -1 -2 -2 -2 -2 -2 -2 +1 +2 B -1 -2 +1 +2 +2 PROVIDE HEAT TRACE 15 METERS OF LENGTH -1 +1 TO STRIPLIGHT TO RECEPTACLE AS REQUIRED -1 -2 +1 +2 REFER TO CIVIL DRAWINGS TO STRIPLIGHT C19 -1 +1 +1 +1 +1 +1 +2 +2 +2 +2 +2 -1 -1 -1 -1 -1 -2 -2 -2 -2 -2 \\192.168.200.200\Nelson\Projects\0000-0999\0000-0099\0029 - RMOW\264 - Gateway Loop Project\501-Drawings\a-Production Drawings\E-106.dwg -2 +1 +2 -2 FROM PANEL OR PREVIOUS JB CONTINUE TO COLUMN E2 BUS SHELTER LOOP HEAT TRACE DETAIL TYPICAL BSJBX, JB43 AND JB44 DETAIL N.T.S. N.T.S. A A Seal: Rev 0 Date Des Dwn Chk Description of Revision Rev Date Des Dwn Chk Description of Revision 2016-05-31 JvdH JvdH AvdH ISSUED FOR TENDER RESORT MUNICIPALITY OF WHISTLER GATEWAY LOOP PROJECT ELECTRICAL BENCH/CURB, HEAT TRACE, AND JB DETAILS Project No. Group 1 2 3 4 5 6 29.264 ELECTRICAL Drawing No. Rev. E106 7 0 1 3 2 5 4 6 7 DRAWING LIST ARCHITECTURAL SHEETS N A1.0 SERIES - SITE, DEMO AND COMPLIANCE PLANS A1.01 Site Plan, Legends and Schedules A2.0 SERIES - OVERALL FLOOR PLANS E A2.01 L1 Plan A2.02 Roof Plan E A3.0 SERIES - REFLECTED CEILING PLANS A3.01 L1 RCP A5.0 SERIES - ELEVATIONS/SECTIONS A5.01 Elevations and Sections A5.11 Sections and Details EQUIPMENT LEGEND duplex receptacle D D recessed light - see electrical drawings ARCHITECTURAL GRAPHIC LEGEND grid line identification 2 LEVEL NAME A drawing number Extent of roof above 46952 elevation relative to top of curb X AX.XX sheet number 1 1000 Extent of curb below refer to civil and landscape section reference assembly tag / refer to assembly schedule WXX J centre line C C 12943 10 A2.01 ABBREVIATION LEGEND affe c/w eq na pt ptd rec reqd sim stn t/o typ u/s wd 4 Bench - refer to landscape = above finished floor elevation = complete with = equal = not applicable = pressure treated = painted = recessed = required = similar = stain = top of = typical = underside = wood ASSEMBLY SCHEDULE B B SYMBOL ASSEMBLY DESCRIPTION SHEET METAL ROOFING Varies 200mm 3mm 245mm sheet metal roofing pt wood shim sloped to drain modified bituminous membrane wood structure - see structural R1 1 Site plan 1 : 200 Note: all conduits shall run above wood decking. No exposed conduits shall be permitted. M :5 9 7 -4 6 1 0 2 D E V A S 2016-05-30 10:06:25 PM C:\CADtemp\1434 wgw_brian.rvt A O :\0 4 sB 6 2 -9 l-I 4 w K d e u 3 6 1 0 x\2 o m e T g w _D 1 a lp L W \K te 1 _m 0 _2 4 _B g .w -D h c A e rd o C A # A Seal: KERR WOOD LEIDAL consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 E mail@kwl.ca 215 – 309 W CORDOVA ST VANCOUVER BC V6B 1E5 TEL 604 738 4323 FAX 604 873 4313 WWW.PUBLICDESIGN.CA Copyright reserved. This design and drawing is the exclusive property of WMW Public Architecture and Communication Inc. and cannot be used for any purpose without the written consent of the Architect. This drawing is not to be used for construction until issued for that purpose by the Architect. Prior to commencement of the Work the Contractor shall verify all dimensions, datums and levels to identify any errors and omissions; ascertain any discrepancies between this drawing and the full Contract Documents; and, bring these items to the attention of the Architect for clarification. Rev Date 0 2016-5-31 Des Dwn Chk Description of Revision Rev Date Des Dwn Chk Description of Revision Whistler Gateway Loop Redevelopment 4313 Village Gate Boulevard, Whistler, BC ISSUED FOR TENDER Site Plan, Legends and Schedules F (604) 294-2090 Project No. Date 1 2 3 4 5 6 1434 March 14, 2016 Drawing No. A1.01 7 Rev. 0 1 3 2 5 4 6 Paint all exposed surfaces and fasteners with Matthews Acrrylic Polyurethane, with clear coat satin finish. 595 Aluminum sign Shim E 28 0° 60.0 40 60 .0 0° 12 Slope to drain T.O. Bus 3 A2.01 60.00° Unit paving refer to landscape Paint all exposed surfaces and fasteners with Matthews Acrrylic Polyurethane, with clear coat satin finish. Aluminum sign T.O. Curb 4100 7 2 A2.01 T.O. Bus 3M custom inks print direct to 3930 with 3M approved UV/Graffiti vinyl over-laminate. Colour: white 0 671.50 8 N E Galvanized steel structure - refer to structural Paint all exposed surfaces with Matthews Acrrylic Polyurethane, with clear coat satin finish. Concrete structure refer to structural Plan detail - signage 1 10 / A2.01 Section detail - signage at top 2 1 : 10 4 / A2.01 Section detail - signage at grade 3 1 : 10 4100 1 / A2.01 1 : 10 D D A B C T.O. Curb 671.50 3 A2.01 60 .0 0° D E 1 0 7 A5.01 Elevation detail - monument signage 4 F A5.01 3 / A5.01 1 : 25 1 3700 G H 2 Galvanized steel structure - refer to structural J Valley in roof above Extent of roof above C Extent of concrete structure below grade - refer to structural 5543 12943 9 A5.11 C Signage A5.01 4 1762 3 3700 635 4 Site furnishings refer to landscape Signage 120 9 3 0 370 1 A2.01 B 554 3 A5.01 1762 12 0 .0 0° B 3 554 3 554 0 370 3 554 6 A5.01 554 3 2 554 Note: all conduits shall run above wood decking. No exposed conduits shall be permitted. 10 1 / A1.01 Floor plan 1 : 100 M :5 9 7 -4 6 1 0 2 D E V A S 2016-05-30 10:06:25 PM C:\CADtemp\1434 wgw_brian.rvt A O :\0 4 sB 6 2 -9 l-I 4 w K d e u 3 6 1 0 x\2 o m e T g w _D 1 a lp L W \K te 1 _m 0 _2 4 _B g .w -D h c A e rd o C A # A Seal: KERR WOOD LEIDAL consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 E mail@kwl.ca 215 – 309 W CORDOVA ST VANCOUVER BC V6B 1E5 TEL 604 738 4323 FAX 604 873 4313 WWW.PUBLICDESIGN.CA Copyright reserved. This design and drawing is the exclusive property of WMW Public Architecture and Communication Inc. and cannot be used for any purpose without the written consent of the Architect. This drawing is not to be used for construction until issued for that purpose by the Architect. Prior to commencement of the Work the Contractor shall verify all dimensions, datums and levels to identify any errors and omissions; ascertain any discrepancies between this drawing and the full Contract Documents; and, bring these items to the attention of the Architect for clarification. Rev Date 0 2016-5-31 Des Dwn Chk Description of Revision Rev Date Des Dwn Chk Description of Revision Whistler Gateway Loop Redevelopment 4313 Village Gate Boulevard, Whistler, BC ISSUED FOR TENDER L1 Plan F (604) 294-2090 Project No. Date 1 2 3 4 5 6 1434 March 14, 2016 Drawing No. A2.01 7 Rev. 0 1 3 2 5 4 6 7 N E E A B C D E 1 1 A5.11 6777 F A5.01 1 7 A5.01 H Overflow scupper 2 A5.11 7395 2 G J Built in gutter 5545 D D 9 A5.11 2.7% 3 A5.11 1 A5.11 % 20.0 6410 RD A5.01 4 R1 3.6% 3 9.4% R1 5545 3.6% 6411 R1 4 7395 RD 2.7% 3 C A5.01 C Sheet metal roofing 5545 Snow retention system Roof drain c/w heat tracing refer to civil and electrical Extend heat trace 1000mm diameter beyond roof drain 6 A5.01 B B Note: all conduits shall run above wood decking. No exposed conduits shall be permitted. M :5 9 7 -4 6 1 0 2 D E V A S 2016-05-30 10:06:27 PM C:\CADtemp\1434 wgw_brian.rvt A O :\0 4 sB 6 2 -9 l-I 4 w K d e u 3 6 1 0 x\2 o m e T g w _D 1 a lp L W \K te 1 _m 0 _2 4 _B g .w -D h c A e rd o C A # A Seal: KERR WOOD LEIDAL consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 E mail@kwl.ca 215 – 309 W CORDOVA ST VANCOUVER BC V6B 1E5 TEL 604 738 4323 FAX 604 873 4313 WWW.PUBLICDESIGN.CA Copyright reserved. This design and drawing is the exclusive property of WMW Public Architecture and Communication Inc. and cannot be used for any purpose without the written consent of the Architect. This drawing is not to be used for construction until issued for that purpose by the Architect. Prior to commencement of the Work the Contractor shall verify all dimensions, datums and levels to identify any errors and omissions; ascertain any discrepancies between this drawing and the full Contract Documents; and, bring these items to the attention of the Architect for clarification. Rev Date 0 2016-5-31 Des Dwn Chk Description of Revision Rev Date Des Dwn Chk Description of Revision Whistler Gateway Loop Redevelopment 4313 Village Gate Boulevard, Whistler, BC ISSUED FOR TENDER Roof Plan F (604) 294-2090 Project No. Date 1 2 3 4 5 6 1434 March 14, 2016 Drawing No. A2.02 7 Rev. 0 1 3 2 5 4 6 7 N E E A B C D D D 7 A5.01 E 1 F A5.01 1 G Fold line 3 A5.11 Galvanized steel structure - refer to structural 2 H 2 A5.11 Align power outlet to centre of triangle - refer to electrical J Panel joint - refer to structural Wood structure refer to structural Fold line 9 A5.11 Align power outlet to centre of triangle - refer to electrical Signage A5.01 4 C C 3 EQ EQ typ Align power outlet to centre of triangle - refer to electrical typ typ EQ 4 A5.01 typ EQ 3 Transformer refer to electrical Signage Wifi antennae - refer to electrical Transformer refer to electrical B Align power outlet to centre of triangle - refer to electrical B Transformer refer to electrical Centre equipment in triangles typical 6 A5.01 Note: all conduits shall run above wood decking. No exposed conduits shall be permitted. All exposed electrical equipment shall be painted black. M :5 9 7 -4 6 1 0 2 D E V A S 2016-05-30 10:06:30 PM C:\CADtemp\1434 wgw_brian.rvt A O :\0 4 sB 6 2 -9 l-I 4 w K d e u 3 6 1 0 x\2 o m e T g w _D 1 a lp L W \K te 1 _m 0 _2 4 _B g .w -D h c A e rd o C A # A Seal: KERR WOOD LEIDAL consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 E mail@kwl.ca 215 – 309 W CORDOVA ST VANCOUVER BC V6B 1E5 TEL 604 738 4323 FAX 604 873 4313 WWW.PUBLICDESIGN.CA Copyright reserved. This design and drawing is the exclusive property of WMW Public Architecture and Communication Inc. and cannot be used for any purpose without the written consent of the Architect. This drawing is not to be used for construction until issued for that purpose by the Architect. Prior to commencement of the Work the Contractor shall verify all dimensions, datums and levels to identify any errors and omissions; ascertain any discrepancies between this drawing and the full Contract Documents; and, bring these items to the attention of the Architect for clarification. Rev Date 0 2016-5-31 Des Dwn Chk Description of Revision Rev Date Des Dwn Chk Description of Revision Whistler Gateway Loop Redevelopment 4313 Village Gate Boulevard, Whistler, BC ISSUED FOR TENDER L1 RCP F (604) 294-2090 Project No. Date 1 2 3 4 5 6 1434 March 14, 2016 Drawing No. A3.01 7 Rev. 0 1 3 2 5 4 6 7 A5.01 7 Wood structure refer to structural N Snow retention system Sheet metal roofing E E 4100 1526 1638 T.O. Bus Note the underside of signs from gridline B to H shall align. Signs vary in length. Refer to elevations. Aluminum sign Wood structure see structural T.O. Bus 4100 3700 5782 12 4885 Signage Galvanized steel structure - see structural 2 Section detail - signage to R1 5 / A5.01 T.O. Curb 1 : 10 2 A5.01 671.50 0 100 Elevation north 1 D 100 100 Wood structure refer to structural T.O. Bus 10 / A2.01 1 : 100 9 A5.11 9 A5.11 4 3 2 1 1 2 3 4 3M custom inks print direct to 3930 with 3M approved UV/Graffiti vinyl over-laminate. Colour: white 4 300 Sheet metal roofing trim 5 Sheet metal roofing 7 / A5.01 4 A2.01 C 4100 T.O. Bus 3700 300 1 : 10 9 A5.11 3 3700 5543 3700 Galvanized steel structure - see structural T.O. Curb 0 671.50 T.O. Curb 0 C Snow retention system 671.50 R1 1 A5.11 4 1 : 100 10 / A2.01 Elevation west 1 : 100 See struc Elevation east 950 10 / A2.01 1 Signage Galvanized steel structure - see structural 3 2 4100 Wood structure see structural Wood structure see structural D Paint all exposed surfaces with Matthews Acrrylic Polyurethane, with clear coat satin finish. Elevation detail - signage 4 T.O. Bus 4100 7 A5.01 4 A5.11 Wifi antennae - refer to electrical T.O. Bus 400 5 A5.01 8 A5.11 4100 Roof scupper Wood structure see structural Signage Rain water leader c/w heat tracing refer to civil and electrical B 3700 Sheet metal roofing Galvanized steel structure - see structural Heat tracing service well - refer to electrical and civil T.O. Bus 4100 Paved surface - see landscape and civil 10 A5.11 Footings beyond see structural B T.O. Curb Wood structure see structural 671.50 0 Concrete structure - see structural Signage Galvanized steel structure - see structural T.O. Curb 0 671.50 Perimeter drainage - refer to civil 6 M :5 9 7 -4 6 1 0 2 D E V A S 2016-05-30 10:06:33 PM C:\CADtemp\1434 wgw_brian.rvt A O :\0 4 sB 6 2 -9 l-I 4 w K d e u 3 6 1 0 x\2 o m e T g w _D 1 a lp L W \K te 1 _m 0 _2 4 _B g .w -D h c A e rd o C A # 10 / A2.01 Elevation south 7 1 : 100 10 / A2.01 Seal: KERR WOOD LEIDAL consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 E mail@kwl.ca 215 – 309 W CORDOVA ST VANCOUVER BC V6B 1E5 TEL 604 738 4323 FAX 604 873 4313 WWW.PUBLICDESIGN.CA Copyright reserved. This design and drawing is the exclusive property of WMW Public Architecture and Communication Inc. and cannot be used for any purpose without the written consent of the Architect. This drawing is not to be used for construction until issued for that purpose by the Architect. Prior to commencement of the Work the Contractor shall verify all dimensions, datums and levels to identify any errors and omissions; ascertain any discrepancies between this drawing and the full Contract Documents; and, bring these items to the attention of the Architect for clarification. Rev Date 0 2016-5-31 Des Dwn Chk Note: all conduits shall run above wood decking. No exposed conduits shall be permitted. Section - transverse looking west 1 : 50 Description of Revision Rev Date Des Dwn Chk Description of Revision Whistler Gateway Loop Redevelopment 4313 Village Gate Boulevard, Whistler, BC ISSUED FOR TENDER Elevations and Sections F (604) 294-2090 Project No. Date 1 2 3 A 4 5 6 1434 March 14, 2016 Drawing No. A5.01 7 Rev. 0 1 3 2 5 4 6 2 2 4 Vent E Built in gutter 50 50 Pt wood blocking 13 R1 Galvanized steel structure - refer to structural 2 1 : 10 Section detail - R1 at roof scupper 1 / A2.02 1 : 10 1 / A2.02 1 : 10 Conduit - refer to electrical 2 573 with s tructu ra l Heat trace - refer to electrical 9 / A5.11 1 : 10 9 / A5.11 Rain water leader - refer to civil T.O. Bus Light fixture refer to electrical E Section detail - R1 at beams from grid A to C and G to J 1 : 10 8 / A5.11 Caulk and backer rod C 8 1 : 10 Galvanized steel angle on radius to align with column - refer to structural 150 Galvanized steel structure - refer to structural Plan detail - column above light fixture 7 Steel sleeves for wire and rain water leader refer to structural 7 A5.11 40 Galvanized steel angle on radius to align with column - refer to structural 4100 Light fixture refer to electrical Caulk and backer rod Cut bottom of beam to expose full layer of glue lam 6 Heat trace - refer to electrical Power for light fixture - refer to electrical coord 950 Top and bottom of beam to be cut to align with adjacent structure D Wood structure refer to structural 7 A5.01 Section detail - R1 at fascia and sloped soffit 5 1 : 10 15.00° R1 Section detail - R1 at roof drain 2 Galvanized steel structure - refer to structural C Galvanized steel structure - refer to structural 7 / A5.01 Rain water leader - refer to civil Power outletrefer to electrical Heat trace refer to electrical R1 Rain water leader - refer to civil 4 Vent Light fixture refer to electrical Power for lighting - refer to electrical Section detail - R1 at typical column 3 R1 D Modified bituminous membrane c/w binder bar Built in gutter Power for lighting - refer to electrical Power outletrefer to electrical Section detail - R1 at fascia and horizontal soffit Caulking 100 13 Caulk and backer rod 125 R1 R1 Pt wood blocking 100 Modified bituminous membrane 2530 Sheet metal roofing trim c/w concealed clip 300 200 Modified bituminous membrane c/w binder bar 1 / A2.02 50 50 Caulking 100 560 Conduit - refer to electrical N E 400 Built in scupper 1 Extend heat trace 1000mm diameter beyond roof drain - refer to Roof Plan 360 Sheet metal roofing trim c/w concealed clip Light fixture refer to electrical 7 7 / A5.01 Section detail - light fixture at top of typical column 1 : 10 2 Galvanized steel structure - refer to structural 7 A5.01 Unit paving refer to landscape 450 Heat tracing inspection chamber - refer to electrical and civil T.O. Curb 0 671.50 Rain water leader - refer to civil 5 A5.11 6 A5.11 sim R1 B Wood structure see structural 150 6 A5.11 sim 3 A5.11 R1 R1 B T.O. Bus Grout- refer to structural Heat tracing refer to electrical 4100 Concrete structure refer to structural Galvanized steel structure - see structural Paved surface - see landscape and civil T.O. Curb 0 671.50 Footings beyond see structural Perimeter drainage - refer to civil Concrete structure - see structural M :5 9 7 -4 6 1 0 2 D E V A S 2016-05-30 10:06:34 PM C:\CADtemp\1434 wgw_brian.rvt A O :\0 4 sB 6 2 -9 l-I 4 w K d e u 3 6 1 0 x\2 o m e T g w _D 1 a lp L W \K te 1 _m 0 _2 4 _B g .w -D h c A e rd o C A # Section - longitudinal looking north 9 10 / A2.01 10 1 : 100 7 / A5.01 Seal: KERR WOOD LEIDAL consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 E mail@kwl.ca 215 – 309 W CORDOVA ST VANCOUVER BC V6B 1E5 TEL 604 738 4323 FAX 604 873 4313 WWW.PUBLICDESIGN.CA Copyright reserved. This design and drawing is the exclusive property of WMW Public Architecture and Communication Inc. and cannot be used for any purpose without the written consent of the Architect. This drawing is not to be used for construction until issued for that purpose by the Architect. Prior to commencement of the Work the Contractor shall verify all dimensions, datums and levels to identify any errors and omissions; ascertain any discrepancies between this drawing and the full Contract Documents; and, bring these items to the attention of the Architect for clarification. Rev Date 0 2016-5-31 Des Dwn Chk Description of Revision Rev Date Des Dwn Chk Note: all conduits shall run above wood decking. No exposed conduits shall be permitted. Section detail - column base A 1 : 10 Description of Revision Whistler Gateway Loop Redevelopment 4313 Village Gate Boulevard, Whistler, BC ISSUED FOR TENDER Sections and Details F (604) 294-2090 Project No. Date 1 2 3 4 5 6 1434 March 14, 2016 Drawing No. A5.11 7 Rev. 0 SAVED 2016-05-30 1:27 PM 1 STRUCTURAL STEEL 1. 1. Design of foundations is based on the geotechnical report of March 9, 2016 by Thurber Engineering. Any interpretation of the geotechnical report by the Contractor is solely the responsibility of that Contractor. 1. Perform all Work in accordance with CSA A23.1, the RSIC Manual of Standard Practice, and Specification Section 03 20 00. 1. Perform all Work in accordance with CSA S16 and Specification Section 05 12 00. The raft foundation has been designed for a factored bearing pressure of 150 kPa and Ks=16,000 kN/m3 , as stated in the geotechnical report. All foundation shall bear on soil capable of supporting this pressure without failure or undue settlement. If native soil or fill are found during construction to have a lower bearing pressure, notify the Geotechnical Engineer and Consultant, and provide revised foundations to the Consultant’s specifications. 2. Deliver, store, and handle steel reinforcement, welded wire fabric, and accessories to prevent bending and damage. 2. 2. Where connection forces are shown on the Drawings, connections shall be designed by a Professional Engineer, retained by the steel fabricator and experienced in the design of this Work. 3. Reinforcing shall be new billet steel conforming to the following standards: 5. E 6. 7. 8. 9. Read structural Drawings in conjunction with other related Drawings, including existing Drawings, for dimensions, elevations, roof and floor slopes, presence of openings and inserts, existing underground services, and existing mechanical/electrical elements. Do not scale off of the Drawings or digital files. Written dimensions take precedent. Hard copy Drawings are the official documents for the Project and take precedence over digital files. For Projects overseen by a Construction Manager or Design-Build Contractor in lieu of a General Contractor, references in all notes and specifications to “Contractor” shall apply to the relevant Subcontractor(s). CSA G30.18, Grade 400 CSA G30.18, Grade 400W (welding to CSA W186) Contractor shall retain a Professional Geotechnical Engineer to design and supervise excavation, shoring, and underpinning of adjacent structures, where required. All costs are to be included in this Contract. c) Welded wire mesh (plain) ASTM A185 d) Epoxy coated reinforcement ASTM A775 e) Stud rails ASTM A108 and ASTM A1044 Fy = 350 MPa (51 ksi), Fu = 450 MPa (65 ksi), welding to CSA W59 5. Follow all recommendations given in the geotechnical report for preloading, backfill, drainage, sub-base preparation, and other requirements. 6. Contractor is responsible for all temporary drainage during excavation. 7. See Architectural Drawings and soils report for all elevations and drainage slopes. 8. Where footing elevations vary, follow requirements of typical details shown on Drawings. Contractor shall establish footing elevations based on all requirements, including frost protection, maximum slopes and electrical, mechanical, and architectural information. Unsolicited alternative proposals and unsolicited substitutions of materials, structure, connections, or otherwise must be submitted with sketches and calculations sealed by a Professional Engineer. Alternative proposals and substitutions will require review by the Architect and Consultant. Such review will be undertaken on an additional fee basis, at the Contractor’s cost, and does not guarantee acceptance of the alternative proposal(s). Contractor is solely responsible for bracing the structure and all components during construction, including any underpinning of adjacent structures. These Drawings show requirements for the completed structure only. Contractor is responsible for the design and inspection of falsework, shoring, and reshoring in accordance with WCB standards. 12. Design Loads: a) Gravity Loads: Superimposed Dead Loads 100 Live Load Roof Snow load based on: Importance = 1.0 Normal 0.5kPa Ss= 9.5kPa Sr= 0.9kPa Superimposed dead loads are non-structural dead loads including architectural topping, partitions (for LL<4.8 kPa), roofing material, pavers, ceiling finishes and mechanical/electrical conduits/fixtures. Seismic load based on: Seismic Data Sa (0.2) Sa (0.5) Sa (1.0) Sa (2.0) 0.63 Wind load based on: 9. 10. 11. 50 5. Weldable reinforcement (including deformed anchor bars) must be clearly identified on each piece. 6. Provide the following fillet weld sizes for welding of deformed bar anchors to embed plates: Perform subgrade density testing per “Field Review and Testing” section of these General Notes. Take care not to disturb subgrade after approval and prior to concrete placement. 0.47 0.28 0.16 Importance = 1.0 Normal PGA 0.29 q 1/50= 0.48kPa Site Class E Fa= 0.9 Fv= 1.8 Rd= 1.5 Ro= 1.3 c) 20M (3/4")Ø - 12mm (1/2") 7. Test stud rail assemblies per the “Field Review and Testing” section of these General Notes. 8. Provide minimum reinforcement as follows, unless noted otherwise: a) Wall reinforcement: Provide 50mm (2”) thick concrete ground seal under footings and grade beams if required by site conditions, and/or by Geotechnical Engineer. 250mm (10") wall - 10M @ 400 (16") VERT., EACH FACE STAGGERED 10M @ 400 (16") HORIZ., EACH FACE STAGGERED 14. Bearing surfaces must be protected from freezing before and after footing concrete is cast. 300mm (12") wall - 10M @ 300 (12") VERT., EACH FACE STAGGERED 10M @ 300 (12") HORIZ., EACH FACE STAGGERED 200mm (8") wall - 15M @ 450 (18") VERT., 15M @ 450 (18") HOR., CENTERED 15. Concrete cast under water shall conform to CSA A23.1. 16. Perform concrete material tests per “Field Review and Testing” section of these General Notes. 17. Do not backfill retaining walls until full concrete design strength is reached unless otherwise approved by the Consultant. Confirm with Consultant prior to concrete placement if floor/roof restraint is required prior to backfilling. 18. The “Concrete” and “Reinforcing” sections of these General Notes also apply to this Work. 2. Mix Designs: Concrete is specified according to the performance method per CSA A23.1 Table 5. 100mm (4") 125mm (5") 150mm (6") or less 175mm (7") 190mm to 215mm (7 1/2" to 8 1/2") 225mm to 250mm (9" to 10") 275mm to 300mm (11" to 12") Concrete topping (ie: over steel deck) 9. MIN. 28 DAY EXPOSURE REPLACEMENT STRENGTH CLASSIFICATION FLY ASH FOR MPa (psi) CEMENT(%) All codes and documents referred to in these General Notes are to be the current adopted edition. 15. Design of secondary component items, including their attachment to the structure, is the responsibility of others. See “Secondary Components and Their Attachments” section of these General Notes. Foundations and Footings 30 (4350) - 30 Supply of Record Drawings is outside the scope of services. Columns 30 (4350) F2 30 a) All structural Work requires written review by the Consultant, including concrete reinforcement, masonry reinforcement (including non-load-bearing partitions), structural steel (including decking), and wood framing (including sheathing). Consultant review is for general compliance with structural concepts only. Contractor remains solely responsible for building the work in conformance with the contract documents. All surfaces placed in contact with ground Formed surfaces exposed to ground or weather Walls Column ties - interior Column ties - exterior Slabs Slab bands and Beams Parking slab - top - bottom i) Slab on grade (from top of slab) j) Other, unless otherwise noted F2 30 Exterior 32 (4650) C2 30 Masonry Grout 20 (3000) - 50 0 30 (4350) 2. C e) Fly ash replacement (where noted) is the mass of fly ash as a percentage of the total mass of cementitious materials. Independent Testing Agency Review: The Owner shall appoint and pay for the services of independent, CSA-certified testing agencies, subject to approval by the Consultant, for the items listed below. Testing agencies shall provide written reports of all test results to the Contractor and the Consultant. f) Where masonry grout strength is determined by cylinder tests, cylinder strength must meet or exceed 70% of the strength listed. a) Subgrade Density Testing: Test subgrade material immediately prior to installation of slab on grade components and during lifts as specified by the Geotechnical Engineer. g) Submit mix designs for each concrete mixture to the Consultant and testing agency for review and approval a minimum of 14 days prior to concrete placement. Identify elements for which each mix design is intended. b) Concrete Materials Testing: 1) Perform compressive strength tests in accordance with CSA A23.2. Unless permitted by the Consultant, cast a minimum of three test cylinders for each 50 cubic meters / 50 cubic yards or each day’s pour, whichever is less. Test one at seven days and two at 28 days. (For concrete with more than 25% fly ash replacement, cast a minimum of four test cylinders. Test one at seven days, one at 28 days, and two at 56 days.) Test reports shall identify the locations where concrete is being tested, with gridlines and elevations. 3) Submit concrete test results maximum 48 hours after test. 1) Perform compressive strength tests in accordance with CSA A165.1 for each type of unit provided. 12. Accurately place all reinforcement. Chair and tie reinforcement to prevent displacement and to maintain specified cover. Do not tack weld crossing reinforcing bars. Install column reinforcement accurately with templates. Protect chairs against rusting where required for appearance. 13. Provide CSA standard hooked dowels from bottom of footings to match and lap with verticals. Install masonry dowels accurately to align with center of walls. Do not wet dowel reinforcement unless approved by the Consultant. 14. Distributed reinforcement in concrete shear walls shall conform to the following: See Architectural drawings for slab elevations, slab edge locations, drainage, slopes, and locations of reglets, reveals, and chamfers. Unless noted otherwise, bevel exposed corners of slabs, beams, slab bands, columns, and walls 20mm x 20mm (3/4” x 3/4”). 15. Coordinate with Work of other Sections in forming and placing openings, keyways, slots, reglets, recesses, waterstops, bolts, anchors, and other inserts. 7. Blockouts, nailers, conduits, ducts, pipes, sleeves, and other openings are subject to approval by the Consultant. 17. Provide continuous bars, properly lapped at splices. Bend and lap horizontal reinforcement at all corners and intersections. Lap splices not shown on the Drawings are not permitted unless approved in writing by the Consultant. 18. Unless noted otherwise, lap lengths, including dowels, for 400 MPa (58 ksi) reinforcement shall be as follows: Epoxy coated bars 10M - 400mm (16") 10M - 500mm (20") 15M - 600mm (24") 15M - 750mm (30") 20M - 750mm (30") 20M - 980mm (39") 25M - 1170mm (46") 25M - 1530mm (60") 30M - 1400mm (55") 30M - 1840mm (72") 2) Heat the formwork or soil surface. Do not cast concrete against any surface with a temperature less than 3°C. Calcium chloride or other de-icing salts are not permitted. 19. Placing and reinforcement shall be reviewed by the Consultant or the Consultant’s agent prior to any concrete being placed. See “Field Review and Testing” section of these General Notes. 3) Cover concrete with insulation blankets for the first 36 hours after concrete placement. Do not cast concrete when temperature is expected to fall below -10°C within 36 hours after placement. 20. Reinforcing not indicated on the structural Drawings needed for support of mechanical or electrical items (e.g. radiant piping, conduit, etc.) is the responsibility of the Contractor. Assume a minimum of 10M bars spaced at 350mm (14”) in one direction for areas without structural top reinforcing. Carry out all hot and cold weather concrete Work in accordance with CSA A23.1. a) When temperature is expected to fall between 3°C and -10°C within 3 days of pouring concrete, the Contractor shall carry out one or more of the following procedures: 1) Heat mix water or aggregate to maintain a minimum concrete temperature of 10°C. 4) In addition to the Fabricator’s in-house quality control testing of stud rail fusion machine welds, perform in-shop visual inspection of all stud rail assemblies, and provide bend tests or tension tests of fabricated assemblies per ASTM A370 and AWS D1.1, Section 7.3.2 and Figure 7.2. Test a minimum of 2% of the total stud rail assemblies of each type, subject to confirmation and approval of the Consultant. Test each stud within the rails selected for testing. (a) Stud rails used for testing are not permitted to be used in the structure. (b) Submit test results prior to concrete placement. 4) Provide a heated enclosure to maintain the temperature of all concrete surfaces above 10°C for a minimum of 36 hours after placement. 5) Provide alternate mix designs for cold weather. 21. Provide contingency reinforcing additional to all other requirements, with "add" and "delete" unit prices included in bid. Include reinforcing required for non-structural concrete and masonry shown on the various drawings. 1) Cool concrete to maintain a maximum temperature of 30°C. 2) Prevent concrete from drying. 9. Perform concrete material tests per “Field Review and Testing” section of these General Notes. 10. Take measures to minimize shrinkage cracking, including covering and dampening concrete during the curing stage. 11. Take all precautions to ensure exposed concrete achieves finish desired by the Architect, including proper forming, mix design, site care, and adequate vibration. Protect against damage during stripping and entire construction period. 12. Repair and patch defective areas when approved by Consultant and Architect. Remove and replace concrete that cannot be repaired and patched to Consultant’s and Architect’s approval. 14. Unless otherwise noted, provide 3.2mm (1/8”) wide x T/4 deep contraction joints in two directions in slabs on grade. Center joints on column lines, and space at maximum 4500mm (15 feet) o.c. (T = slab thickness.) Seal: consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 F (604) 294-2090 E mail@kwl.ca Suite 201 1672 West 1st Ave Vancouver BC Canada V6J 1G1 Rev 0 T 604 731 7412 F 604 731 7620 mail@fastepp.com 2 This drawing is not to be used for construction purposes until noted and dated 'Issued for Construction' All measurements must be checked on site and be verified by the Contractor. Do not scale off hard copy drawings or any electronic/computer files. Written dimensions always have precedent. Hard copy drawings are the official documents for the project and always take precedent over all electronic/computer files. e) Pipe ASTM A53, Grade B f) Bolts ASTM A325 g) Anchor bolts ASTM F1554, Grade 36 h) Deformed bar anchors CSA G30.18, Grade 400W i) Shear Stud Connectors j) Stainless steel ASTM A108, Grades 1015 through 1020, headed-stud type Type 304 Welding of reinforcing to embedded plates is permitted only with weldable deformed bar anchors. Headed stud anchors on embed plates shall also be fillet welded; fusion machine welds are not permitted. See the “Concrete Reinforcing” section of these General Notes for fillet weld sizes. Date Des Dwn Chk 2016-05-31 OB JF NB 10. Hot dip galvanize all steel Work permanently exposed to the weather, including fasteners, unless noted otherwise. Hot dip galvanize all steel connectors and fasteners for wood members exposed to view in the completed structure, where exposure to rain during or after construction may cause rusting or staining of the wood. Galvanizing shall conform to ASTM A123 and A153. 11. Repair galvanized areas that are field welded or otherwise damaged during construction to comply with ASTM A780. 12. Control heat and pace of weld when welding may significantly warp the member or when welding steel adjacent to other materials (wood, concrete, etc.) to prevent cracking, spalling, or burning of adjacent material. 13. Grout fill all voids on underside of all base plates and bearing plates in contact with concrete or masonry. Provide non-shrink grout with a plastic consistency, capable of developing minimum compressive strength of 17 MPa (2500 psi) in 48 hours and 48 MPa (7000 psi) in 28 days. Follow manufacturer’s instructions for mixing and placement. 14. See “Field Review and Testing” section of these General Notes for required reviews by Consultant and independent testing agency. 15. If a structural steel member size specified on the structural Drawings is not available, the Contractor shall immediately notify the Consultant and allow for the next available size up. Contractor is responsible for the cost of any member upsizing due to availability of sizes or grades specified. 16. See architectural Drawings for miscellaneous steel components. Any steel components not shown on the structural Drawings are considered to be secondary components. (See “Secondary Components and Their Attachments” section of these General Notes.) Assume 6mm (1/4”) thickness unless noted otherwise. Description of Revision Rev Date - ANCHOR BOLTS - ADDITIONAL - ALTERNATE - ARCHITECT / ARCHITECTURAL - BOTTOM LOWER LAYER - BOTTOM UPPER LAYER - BOTTOM CHORD EXTENSION - BOTTOM - BUILT UP - FACTORED COMPRESSION FORCE - CANTILEVERED - CENTER OF GRAVITY - CENTERLINE - CLEAR / CLEARANCE - COLUMN - CONCRETE - CONNECTION - CONTINUOUS - COUNTERSINK - CAST IN PLACE - COMPLETE WITH - CONTROL JOINT - CROSS LAMINATED TIMBER - DEAD LOAD - DIAGONAL - DEEP - DRAWING(S) - ELEVATION - ELECTRICAL - EACH FACE - EACH SIDE - EACH WAY - EXISTING - FOUNDATION - FULLY THREADED SCREWS WITH COUNTERSUNK HEADS - FULLY THREADED SCREWS WITH CYLINDRICAL HEADS - FOOTING - GAUGE - GALVANIZED - GRID LINE - GLULAM - HOOK ONE END - HOOK TWO ENDS - HOLD DOWN - HOT DIPPED GALVANIZED - HEADER - HORIZONTAL - INSIDE FACE - LONG Des Dwn Chk LLH LLV L.L. LONGIT. LSL LVL L.V. Mf MAX. MECH. MIN. N.STUDS NTS OPP. O.F. P.C. PL. PLY. PSC PSH PSL PSW P/T REINF. R/W S.D.L. S.O.G. S.S. STAG. STD. STIFF. STIRR. Tf THK. TJI T.L.L. TRANSV. T.U.L. T&B TYP. U.D.L. U.N.O. U/S Vf VERT. WD. WP. C - LONG LEG HORIZONTAL - LONG LEG VERTICAL - LIVE LOAD - LONGITUDINAL - LAMINATED STRAND LUMBER - LAMINATED VENEER LUMBER - LENGTH VARIES - FACTORED MOMENT - MAXIMUM - MECHANICAL - MINIMUM - NELSON STUDS - NOT TO SCALE - OPPOSITE - OUTSIDE FACE - PRECAST CONCRETE - PLATE - PLYWOOD - PARTIALLY THREADED SCREWS WITH COUNTERSUNK HEADS - PARTIALLY THREADED SCREWS WITH HEX HEADS - PARALLEL STRAND LUMBER - THREADED SCREWS WITH WASHER HEADS - POST-TENSION - REINFORCEMENT - REINFORCED WITH - SUPERIMPOSED DEAD LOAD - SLAB ON GRADE - STAINLESS STEEL - STAGGERED - STANDARD - STIFFENER - STIRRUP - FACTORED TENSILE FORCE - THICK - TRUSS JOIST - TOP LOWER LAYER - TRANSVERSE - TOP UPPER LAYER - TOP & BOTTOM - TYPICAL - UNIFORMLY DISTRIBUTED LOAD - UNLESS NOTED OTHERWISE - UNDERSIDE - FACTORED SHEAR FORCE - VERTICAL - WIDE - WORK POINT Description of Revision ISSUED FOR TENDER Copyright reserved. This drawing and design is and at all times remains the exclusive property of Fast+Epp and cannot be used without their written consent and associated disclaimer fees. The information contained herein is for use of the Client only. Fast+Epp is under no obligation to supply electronic/computer files for this project to the Contractor or Subcontractors. Fast+Epp and its employees are not liable to any other parties relating to the use of these drawings. 3 D Provide one coat of shop primer to steel surfaces except the following, or unless noted otherwise: FTG. GA. GALV. G/L GL H1E H2E HD H.D. GALV. HDR HORIZ. I.F. LG. A Fast +Epp CSA G40.20/G40.21 Grade 300W FSZ Do not strip forms for structural elements until concrete strength has reached 50% of the design compressive strength for columns and walls, 70% of the design compressive strength for slabs and beams, and 75% of the design compressive strength for slabs and beams in parking structures. Strength of concrete shall be determined from field-cured cylinders. All shoring and reshoring must be approved by Contractor’s shoring engineer. 13. GSA G40.20/G40.21 Grade 350W, Class C d) Plates and flat bars A.BOLTS ADDL. ALT. ARCH. B.L.L. B.U.L. BCE BOT. B/U Cf CANT. CG. CL CLR. COL. CONC. CONN. CONT. C'SINK C.I.P. C/W CJ CLT D.L. DIAG. DP. DWG(S). EL. ELEC. E.F. E.S. E.W. EXIST. FDN. FSC b) When the temperature is expected to rise above 25°C the Contractor shall: Additional testing and field review resulting from rejection of more than 5% of the Work will be at Contractor’s expense. CSA G40.20/G40.21 Grade 300W c) HSS ABBREVIATIONS c) Unless noted otherwise, where zones change size at the splice because of wall steps, provide dowels for a tension splice above and below. b) Where permitted, space openings two diameters apart, but not less than 150mm (6”). 8. b) Rolled shapes (other) a) Zone dowels to match size and number of vertical bars in zone, unless noted otherwise. Do not field bend reinforcement except where indicated or authorized by the Consultant. When field bending is authorized, bend without heat. Replace bars which develop cracks or splits. c) Single openings larger than 300mm (12”) or a group of openings occupying together more than 300mm x 300mm (1.0 square foot) in any one square meter (10 square feet) are not permitted without approval of the Consultant. CSA G40.20/G40.21 Grade 350W Zone reinforcement in concrete shear walls shall conform to the following: 16. a) Openings and conduits are not permitted in shear wall zones or within 1000mm (39”) of wall ends, wall intersections, and columns. a) Rolled shapes (W-sections) c) Surfaces of high-strength bolted, slip-critical connections b) Do not crank zone bars. At splices the zones shall be offset from the bars below and all bars at the splice shall be contained within ties. 6. e) Adhesive Anchors: Perform in-situ proof load tests of adhesive anchors where indicated on the Drawings and where Contractor has substituted adhesive anchors for cast-in anchors (with Consultant's written permission. Proof load shall be manufacturer's published anchor capacity. If any anchors fail proof load testing, additional tests are required at the discretion of the Consultant, at the Contractor's expense. J:\2200 - 2249\2248 Whistler Gateway Loop\2248_S1.00, S1.01.dwg Clear distance between bars in columns shall not be less than 1.5 times the nominal diameter of the bars, or 38mm (1-1/2”), or 1.5 times the maximum size of the coarse aggregate. 5. 3) Visually inspect all steel deck fasteners. 3. 11. b) Vertical splices shall typically occur at the floor levels. Other splices of horizontal and vertical reinforcement are not allowed except where necessary. These splices must be staggered within each curtain and must be reviewed and approved by the consultant before construction. 1) Inspect and test all shop- and field-bolted connections according to CSA S16. Provide steel conforming to the following standards, unless noted otherwise: a) Surfaces embedded in concrete or mortar Clear distance between bars, except for columns, shall not be less than 1.4 times the nominal diameter of the bar, or 30mm (1 1/4”), or 1.4 times the maximum size of the coarse aggregate. Bars placed in two or more layers shall have a minimum clear distance between the layers of not less than 30mm (1 1/4”) and shall be placed directly above and below each other. Install expansion and/or construction sequence joints in concrete structures greater than 45m (150 ft) in length. Details and locations shall be discussed with and approved by the Consultant in writing prior to construction. d) Steel Testing: 7. b) Surfaces to be field welded 75mm (3") 50mm (2") 32mm (1 1/4") 40mm (1 1/2") 50mm (2") 40mm (1 1/2") 50mm (2") 40mm (1 1/2") 40mm (1 1/2") ----40mm (1 1/2") 4. 3) Test at intervals per CSA S304.1. 2) Inspect all structural steel welds to the following criteria: (a) Visually inspect 100% of all shop and field welds. (b) Magnetic particle test 20% of all shop and field fillet welds. (c) Ultrasonic test 100% of all shop and field complete penetration (CP) welds. 75mm (3") 50mm (2") 32mm (1 1/4") 40mm (1 1/2") 50mm (2") 25mm (1") 40mm (1 1/2") 40mm (1 1/2") 25mm (1") 40mm (1 1/2") 40mm (1 1/2") a) All horizontal reinforcement shall be inside the zone verticals and extend to the end of the wall. Where there are two curtains of reinforcement shown, the vertical bars shall be on the outside of the horizontal bars. 2) Perform mortar aggregate ratio tests (proportion specification) and grout compressive strength and slump tests in accordance with CSA A179 for each mix provided. Protect steel members from corrosion, deformation, and other damage during storage and handling. e) Galvanized surfaces Contractor is solely responsible for design of concrete formwork, shoring, and bracing. All formwork shall conform to CSA S269.3. c) Concrete Masonry Unit Testing: 6. d) Surfaces to receive sprayed fire-resistive materials (applied fireproofing) 3. 2) Perform slump tests and air content tests in accordance with CSA A23.2 for each concrete test. B 10. d) Select maximum aggregate size as required to accommodate rebar congestion and allow for proper finishing (for example at topping slabs). Include maximum aggregate size in mix design submittal. b) Contractor is responsible to give reasonable advance notice of when structural Work is ready for review by the Consultant, minimum 48 hours prior to pour or concealment. Contractor is responsible for reviewing his or her own work and the work of the subtrades prior to review by the Consultant. All steel fabricators and erectors must have full approval of the Canadian Welding Bureau under CSA W47.1. Weld to CSA W59 using welders qualified in accordance with CSA W47.1. 9. Provide concrete protection for reinforcement as follows, unless noted otherwise: Fire Resistance Rating 0-2 hrs. 3 hrs. a) b) c) d) e) f) g) h) Arch. concrete (see Arch.) Slabs on Grade 5. e) Footing reinforcement: 2-15M continuous plus hooked dowels of same size and spacing as wall vertical reinforcing. Other locations not identified above: 15M @ 400 (16") c) Normal weight concrete for various purposes shall be as follows: Consultant Review: Fabricate structural steel members to CISC Code of Standard Practice, CSA W47.1, and CSA W59. All fabrication and welding exposed to view shall be appearance quality to the Architect’s satisfaction. 8. d) Unless noted otherwise, openings in walls and slabs shall have 2-15M extra each side extending 600mm (2'-0") past corners, plus 2-15M x 1200mm (4'-0") diagonal each corner. b) No calcium chloride is permitted in any form in the concrete mixes. 14. 10M @ 500 (20") EACH WAY 10M @ 400 (16") EACH WAY 10M @ 300 (12") EACH WAY 15M @ 500 (20") EACH WAY 15M @ 450 (18") EACH WAY 15M @ 400 (16") EACH WAY 15M @ 350 (14") EACH WAY 152x152 MW 9.1x MW 9.1 welded wire mesh c) Column integrity reinforcing at suspended slabs: 2-20M bottom extra each way, extend minimum 740mm past face of column. See typical detail. a) Cement shall be Type GU Portland cement / type HS for concrete in contact with sulfate soils, unless noted otherwise. 1. 4. 2-15M verts full height at ends of all walls unless noted otherwise Perform all Work in accordance with CSA A23.1 and Specification Sections 03 11 00, 03 20 00, and 03 30 00. Exterior Submit shop drawings showing fabrication and erection of all structural steel components to the Consultant for review prior to fabrication. Show all connections and details, material specifications, and finishes; include an erection layout for all members. Do not proceed with fabrication until shop drawings have been approved by the Consultant. b) Slab reinforcing (or temperature reinforcing) 1. FIELD REVIEW AND TESTING 3. 150mm (6") wall - 10M @ 300 (12") VERT., 10M @ 300 (12") HOR., CENTERED 13. ELEMENTS E d) Protection of connections of dissimilar metals against galvanic corrosion is the responsibility of the Professional Engineer sealing the fabricator's shop drawings. b) 15M (5/8")Ø - 10mm (3/8") Center all footings on columns and walls unless noted otherwise. These Drawings show structural Work required to meet the provisions of Part 4 (and Part 9 where applicable) of the BCBC. c) The Professional Engineer sealing the fabricator’s shop drawings is also responsible for all field review of his or her Work. The Engineer shall provide signed and sealed letters of assurance (Schedules S-B and S-C) to the Consultant confirming the Work has been completed in accordance with the final reviewed shop drawings and all structural requirements. a) 10M (3/8")Ø - 6mm (1/4") 12. Importance = 1.0 Normal 16. Provide weldable reinforcement in concrete shear walls and frame members with force modification factors Rd greater than 2.0 (see "General" section of these General Notes). Footing elevations, if shown, are for bidding purposes only. They are not final and may vary according to site conditions. All footings must be taken to a bearing layer approved by the Geotechnical Engineer. Contractor is solely responsible to ensure the Geotechnical Engineer reviews and confirms bearing pressure and approves subgrade installation prior to casting concrete for footings. b) Drawings and calculations of components designed by the steel fabricator shall be signed and sealed by the Professional Engineer. Drawings shall include connection design forces for each representative member connection. 4. CONCRETE b) Seismic and Wind Loads: 13. a) 10M and larger b) Weldable reinforcement Prior to commencement of Work, Contractor shall compare all related Drawings, confirm all dimensions, and field measure/confirm all existing conditions. Report any discrepancies to the Architect and Engineer of Record (“Consultant” henceforth). If discrepancies relating to structural Work are found in the various documents, the more stringent provisions shall apply, unless approved by the Consultant. Specifications control over these Drawings and General Notes only where the Specifications provide for more stringent requirements. Contractor, suppliers, and subtrades are to ensure they are working with the “Issued for Construction” documents. a) Design connections for minimum half the shear or compression capacity of the members connected unless noted otherwise. Provide a minimum of two 19mm (3/4”) diameter A325 bolts with a 9mm (3/8”) connector plate, or an equivalent weld. Minimum depth of frost penetration is estimated to be 0.7m, as stated in the geotechnical report. 4. 11. Do not cut or drill openings in any portion of the structure without written approval of the Consultant. D 3. Where notes and specifications require submittals by a Professional Engineer, the Engineer must be licensed at the place where the Project is located. 10. All shop drawing reviews by the Consultant constitute review for general concepts only. Contractor remains responsible for the detailed design. Assemble and erect all components in accordance with final reviewed shop and erection drawings. Do not fabricate or erect until Consultant has completed review. 1 7 REINFORCING 4. millimeters 6 FOUNDATIONS 3. 10 5 4 GENERAL 2. Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm 3 2 B DRAWING LIST No. DWG. No. 1 S1.00 GENERAL NOTES - SHEET 1 2 S1.01 GENERAL NOTES - SHEET 2 3 S2.00 FOUNDATION PLAN 4 S2.10 ROOF FRAMING PLAN 5 S2.11 ROOF PREFAB PANEL PLAN 6 S2.12 ROOF CLT PANEL PLAN 7 S4.00 SECTIONS AND DETAILS 8 S4.10 SECTIONS AND DETAILS 9 S4.11 SECTIONS AND DETAILS 10 S4.12 SECTIONS AND DETAILS 11 S4.13 SECTIONS AND DETAILS Project No. Group 5 6 A Whistler Gateway Loop Redevelopment GENERAL 4 DWG. TITLE 2248 N/A NOTES - SHEET 1 Drawing No. Rev. S1.00 7 0 SAVED 2016-05-30 1:27 PM 1 3 2 WOOD FRAMING Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm TIMBER FASTENERS AND CONNECTORS General: Clearly identify all fasteners and connection systems on shop drawings. Refer also to "Wood Framing" section of these General Notes where applicable. 1. Perform all Work in accordance with CSA O86 and Specification Section 06 15 23. If European CLT is used, panels shall comply with the manufacturer-specific European Technical Assessment (ETA). 2. Provide the following material grades, unless noted otherwise on the Drawings. All softwood lumber shall conform to CSA O141 and have a maximum moisture content of 19% unless noted otherwise. All Douglas Fir plywood shall conform to CSA O121. 2. Screws: a) Screws are called up on the drawings as follows: 2. Where connection forces are shown on the Drawings, connections shall be designed by a Professional Engineer, retained by the timber fabricator and experienced in the design of this Work. SPF #2 or better b) Top and bottom plates: D.Fir-L #2 or better c) Strapping and nailing strips: Hem-Fir, construction grade b) d) Solid wood posts and beams: D.Fir-L #1 or better e) Floor and roof sheathing: Douglas Fir plywood (DFP), exterior grade 3. Provide minimum 38x235 @ 400mm (2x8 @ 16”) joists unless noted otherwise. Install double joists under parallel non-load bearing partitions above. 4. Provide minimum 38x38 (2x2) bridging or solid blocking between joists at 2100mm (7’-0) o.c. for all spans greater than 3000mm (10’-0), with 13mm (1/2”) gap between bridging. Fully block all joist spaces below point loads. 5. 7. 8. 9. Provide minimum two members for built-up beams and posts. Provide minimum lintel of 2-38x235 (2-2x10) or 89x241 (3-1/2” x 9-1/2”) LSL unless noted otherwise. Install double cripples under lintels. Provide minimum wall studs as follows, unless noted otherwise: a) 1st floor 38x89 @ 300mm (2x4 @ 12”) o.c. or 38x140 @ 400mm (2x6 @ 16”) o.c. b) 2nd floor 38x89 @ 400mm (2x4 @ 16”) o.c. or 38x140 @ 400mm (2x6 @ 16”) o.c. d) Laminate studs solid beneath all beam ends and carry through to concrete foundation below. Provide built-up studs to match number of laminations in built-up member being supported. Take care to ensure beams bear fully on supporting members. Provide minimum sheathing as follows. Place sheets with face grain running perpendicular to supporting members in a staggered joint pattern unless noted otherwise. 100 a) Wall sheathing: 13mm (1/2”) plywood fastened with 75mm (3”) long common nails @ 100mm (4”) o.c. at sheet edges and @ 300mm (12”) o.c. at intermediate studs. Block all unsupported edges with 50mm (2”) nominal blocking and nailed as above. Drill adequate holes in exterior walls for ventilation. e) c) Roof sheathing: 13mm (1/2”) plywood fastened with 75mm (3”) long common nails @ 100mm (4”) o.c. at sheet edges and @ 250mm (10”) o.c. at intermediate supports. Provide H-clips between each joist. 10. D Provide minimum wall anchorage as follows, unless noted otherwise: a) Interior bearing walls: Fasten bottom wall plate to concrete with 16mm diameter x 250mm long (5/8” diameter x 10” long) anchor bolts @ 1200mm (4’-0) o.c. maximum. Provide bolts with standard nut and washer at top, and double nuts and standard washer at bottom. Provide bolts maximum 200mm (8”) from ends and corners of walls and edges of window and door openings. Where hold down is indicated on the Drawings, increase edge distance to 300mm (12”). f) 50 b) Exterior bearing walls and shear walls: Fasten bottom wall plate to floor sheathing with 95mm (3-3/4”) long spikes @ 100mm (4”) o.c. Fasten bottom wall plate to concrete with 20mm diameter x 250mm long (3/4” diameter x 10” long) anchor bolts @ 750mm (2’-6) maximum. Provide bolts with 65mm diameter x 6mm thick (2-1/2” diameter x 1/4” thick) plate washers at top of bolts, and double nuts and standard washer at bottom. Provide bolts maximum 200mm (8”) from ends and corners of walls and edges of window and door openings. Add hold down anchors where noted on plan; for walls above the foundation level, hold downs noted at the base of the wall are also required at the top of the wall below. Connect shear walls to floor/roof plywood above (connect through blocking or joists where required) with minimum 75mm (3”) long nails @ 100mm (4”) o.c. c) Lap top wall plates 1200mm (4’-0) and connect with 12-75mm (3”) long nails minimum unless noted otherwise. 11. TOPIX Countersunk Partially Threaded HBS (wood to wood applications only) WFC WFR ASSY 3.0 Eco MULTI Head Partially Threaded Fastener Type SFS Intec SWG WFD ASSY 3.0 Kombi 5. 6. The following partially threaded screws with washer heads (PSW) are acceptable, unless noted otherwise on the Drawings: Manufacturer Fastener Type HECO RothoBlaas SWG SPAX TOPIX Washer Head Partially Threaded TBS ASSY 3.0 SK SPAX Washer Head Partially Threaded 9. Manufacturer Fastener Type HECO RothoBlaas SFS Intec SWG SPAX TOPIX VGS WR ASSY VG CSK (countersunk head) MULTI Head Fully Threaded The following fully threaded screws with cylindrical heads (FSZ) are acceptable, unless noted otherwise on the Drawings: All wood framing and sheathing shall be reviewed by the Consultant or the Consultant’s agent prior to concealment. See “Field Review and Testing” section of these General Notes. m) Library stacks. n) Roofing material. o) Parking slab membrane. 10. Mark panels for identification during erection. Ensure that marks will be concealed from view in final assembly. Clearly mark top surface. 11. Make adequate provision for possible erection stresses. Set panels level and plumb to correct positions. Securely brace panels and anchor in place to maintain plumb until permanently secured by finished structure. 12. Fit panels closely and accurately, without trimming, cutting, or other modifications, unless approved in writing by the Consultant. Site cutting or boring of panels, other than shown on shop drawings, is not permitted without written consent of the Consultant. Coat all field-cut openings with minimum two coats of clear sealer. 14. See Timber "Fasteners and Connectors" section of these General Notes for requirements related to threaded wood screws and other proprietary connection systems. All accessories are to be painted in accordance with Architect’s specifications or hot dip galvanized prior to shipping to site. See “Structural Steel” section of these General Notes for galvanization requirements. Where screws are used in combination with architecturally exposed steel plates, where a flush head is required, or where screws are not perpendicular to steel plate, use screws with countersunk heads unless noted otherwise. Countersink holes in steel to receive tapered screw heads. Screw Diameter (mm) Torque (N-m) 8 10 12 18 26 70 Contact consultant for HDG and stainless steel torque values. Contractor installing connections is responsible for testing tool setting as described and notifying consultant of finding prior to commencing work. Labour and materials associated with these tests shall be included in the bid. 3. Specialty Products: All other fastening and connection systems, including but not limited to Simpson, Pitzl, Knapp, Sherpa, HBV, and HSK systems, are specified on the Drawings. Strictly follow product suppliers instructions. 4. HSK connections to be supplied by: TiComTech Geothestrasse 60 63808 Haibach Germany tel: +49(0)6021 / 446 4267 Rainer Bahmer rainer.bahmer@ticomtec.de See architectural Drawings for finish requirements. 16. Provide gradual heating of enclosed building to minimize panel cupping and checking. 2. Protection of connections of dissimilar metals against galvanic corrosion is the responsibility of the specialty Professional Engineer. 4. Elevator requirements: D a) Refer to elevator shop drawings for shaft dimensions, pit depth, location of divider beams and rail support members, and rough opening sizes for doors. Contractor is responsible for confirming all dimensions prior to commencing Work. b) Elevator manufacturer shall provide Consultant with all loads and deflection criteria necessary to size supporting structure, including rail supports, divider beams, hoist beams, pit slabs, and machine room slabs. 5. GLUED-LAMINATED STRUCTURAL UNITS 1. 3. Detail all secondary components for construction tolerances plus the following building movements and deflections: a) Vertical movements: 15. 1) Vertical deflections of beams, slabs, and decking: L/180 (25mm min.) 2) Differential deflections of beams and slabs at adjacent floors at building perimeter: L/240 (16mm min.) b) Horizontal movements: Perform all Work in accordance with CSA O86, CSA O122, and Specification Section 06 18 19. If European glulam is used, members shall comply with EN 14080. Where connection forces are shown on the Drawings, connections shall be designed by a Professional Engineer, retained by the timber fabricator and experienced in the design of this Work. 1) Storey drift due to wind: (Design components to withstand this movement without damage) H/400 2) Storey drift due to earthquake: (Design components to withstand this movement without collapse) H/40 a) Drawings and calculations of components designed by the timber fabricator shall be signed and sealed by the Professional Engineer. c) Movement at expansion joints: b) The Professional Engineer sealing the fabricator’s shop drawings is also responsible for all field review of his or her Work. The Engineer shall provide signed and sealed letters of assurance (Schedules S-B and S-C) to the Consultant confirming the Work has been completed in accordance with the final reviewed shop drawings and all structural requirements. 3. Submit shop drawings showing fabrication and erection of all glulam components to the Consultant for review prior to fabrication. Show all connections and details, material specifications, and finishes; include an erection layout for all members. Do not proceed with fabrication until shop drawings have been approved by the Consultant. 4. Glulam manufacturer shall be certified in accordance with CSA O177 or EN 14080. 5. Individually wrap members with weatherproof, lightproof, stain free material. Protect corners with wood blocking. Store members blocked off ground with spacer blocks so air may circulate around all faces of members. Use padded, non-marring slings for handling. Keep wrapping on members until permanent protection from the weather is in place, but slit underside to prevent accumulation of moisture inside the wrapping. 6. All glulam members shall meet the following specifications unless noted otherwise on plan. Any substitution must have the written approval of the Architect and the Consultant. Submit proposed sealer for review and approval. a) Species: Spruce - Pine to CSA O122 b) Stress Grade: Beams: HSK system to be shop-installed by glulam supplier HSK plates are not to be galvanized. Bid to include all required drillings to inject adhesive and all temporary works required. c) Adhesive: CSA O112, to grade of service required in accordance with CSA O122, clear or white The glulam supplier has to strictly follow the QA / QC procedure provided by the HSK system supplier. The fabricator shall keep a fabrication log including a checklist covering but not limited to the items below. The inclusion of representative pictures is required. a) Adhesive type d) Appearance Grade: Commercial where the panel is concealed, Quality elsewhere e) Sealer: Manufacturer’s standard, transparent, compatible with finish b) Date of production d) The Professional Engineer sealing the Contractor’s shop drawings is also responsible for all field review of his or her Work. The Engineer shall provide signed and sealed letters of assurance (Schedules S-B and S-C) to the Consultant confirming the Work has been completed in accordance with the final reviewed shop drawings and all structural requirements. Apply sealer to all sides of panels. Double coat ends of panels. Coat all cuts, holes, and slots. Submit proposed sealer for review and approval. VGZ ASSY VG CYL Cylindrical Head Fully Threaded h) c) Submit sealed shop drawings of secondary or non-structural components which may affect the primary structural system to the Consultant for review. Shop drawings should clearly indicate the method and means of attachment and the magnitude of forces that the base structure must withstand. The Consultant’s review shall be only for the components’ effect on the primary structural system and may result in the need to modify the method of attachment. C24, 15% maximum moisture content Manufacturer-specific ETA Non-Visual where the panel is concealed, Visual elsewhere RothoBlaas SWG SPAX Traditional lag screws, Simpson SDS/SDW screws, GRK screws, and other specialty screws are acceptable only where specifically indicated on the Drawings. b) Drawings and calculations of components designed by the specialty Professional Engineer shall be signed and sealed by the Professional Engineer. If European CLT is used, panels shall be fabricated to the manufacturer-specific ETA and shall meet the following specification. Any substitution must have the written approval of the Architect and Consultant. Provide moisture barrier at all locations where panels abut concrete or masonry construction. g) Design and detailing of the above items and their attachments are not the responsibility of the Consultant. They shall be designed by specialty Professional Engineers, retained by the Contractor and experienced in the design of this Work. a) Design secondary components in accordance with Part 4 of the British Columbia Building Code and with the design criteria listed in the “General” section of these General Notes. 13. See manufacturer's specifications for all installation details unless noted otherwise. Use low rpm/high torque drills with torque clutch. The use of impact drills is prohibited. For connections using carbon steel screws in combination with steel plates use the following torque: 18. l) Attachments and bracing for mechanical and electrical components. Spruce Pine #1/2 to NLGA, 15% maximum moisture content CSA O112, clear or white Non-Visual where the panel is concealed, Visual elsewhere Fastener Type l) Provide moisture barrier at all locations where framing abuts concrete or masonry construction. j) Window washing equipment, including attachments. All CLT panels shall be fabricated in accordance with APA PRG 320 and shall meet the following specification. Any substitution must have the written approval of the Architect and the Consultant. Manufacturer Contractor to submit one sample of each different type of steel plate assembly, including screws, to Consultant for approval prior to mass fabrication. 17. E i) Elevators, hoist beams, and rail support members. CLT manufacturer shall be certified in accordance with APA PRG 320. If European CLT is used, manufacturer shall be certified with an ETA. Wrap panels with weatherproof, lightproof, stain free material. Protect panel corners with wood blocking during delivery. Store panels blocked off ground and separated with striping. Slit underside of membrane covering during storage at site. Cover top and sides with opaque moisture-resistant membrane if outside. Maintain protection of panels during construction. Contractor and manufacturer shall indicate intended method of protection to the Architect and Consultant prior to construction. a) Laminating stock: b) Adhesive: c) Appearance grade: The following fully threaded screws with countersunk heads (FSC) are acceptable, unless noted otherwise on the Drawings: k) See “Timber Fasteners and Connectors” section of these General Notes for requirements related to threaded wood screws and other proprietary connection systems. g) Interior and exterior light gauge steel stud walls. Submit shop drawings showing fabrication and erection of all CLT panels to the Consultant for review prior to fabrication. Show all connections and details, material specifications, and finishes; include an erection layout for all panels. Do not proceed with fabrication until shop drawings have been approved by the Consultant. a) Laminating stock: b) Adhesives: c) Appearance grade: 8. Substitution of common nails with power-driven nails (P-nails) of the same length and diameter is acceptable. Substitution of power-driven nails of smaller diameter is permitted only with Consultant’s written approval. Set nail gun pressure so that nail heads do not crush plywood surface; nail head penetration shall not exceed 2mm (1/16”). Provide steel plates conforming to CSA G40.20/G40.21 Grade 300W or better. Provide A307 bolts unless noted otherwise. See “Structural Steel” section of these General Notes for galvanization requirements. All fasteners in contact with pressure-treated wood to be hot dip galvanized to ASTM A153. Provide 600mm x 600mm (24” x 24”) sample of each Quality appearance grade panel with shop applied sealer for review and approval by Architect and Consultant. 2. 7. Predrilled holes: Provide holes in steel with diameter not more than 1mm greater than diameter of screw. Where pre-drilling of wood is recommended by the supplier, provide hole diameter strictly per manufacturer's recommendations. Provide galvanized Simpson Strong-Tie connectors or approved alternate where required, unless noted otherwise. Use joist hangers with minimum 4.5 kN (1000 lb) capacity for all flush framing. Fully nailed pressure blocks are permitted only with Consultant’s written approval. e) Architectural precast and precast cladding. k) Fall restraint anchors, including any additional required framing not shown on plans. The following partially threaded screws with hex heads (PSH) are acceptable, unless noted otherwise on the Drawings: Manufacturer d) Skylights and glass canopies. f) Architectural brick veneer and tie backs. 3. 4. j) 14. C HECO RothoBlaas SFS Intec c) Cladding, window mullions, glazing, and store fronts. h) Raised floor systems. Provide sill gasket under all wood sill plates in contact with concrete. Provide peel and stick membrane to all other wood surfaces in contact with concrete. All lag screws must be machined threaded, not cast threaded. Pre-drill holes in accordance with CSA O86. 16. Fastener Type Where screws are used in combination with steel plates not exposed to view, use screws with a hex head unless noted otherwise. Provide hole shape per manufacturer's recommendations for each screw type. 13. 15. Manufacturer b) Architectural components such as guard and hand rails, flag posts, canopies, ceilings, etc. b) The Professional Engineer sealing the fabricator’s shop drawings is also responsible for all field review of his or her Work. The Engineer shall provide signed and sealed letters of assurance (Schedules S-B and S-C) to the Consultant confirming the Work has been completed in accordance with the final reviewed shop drawings and all structural requirements. i) 0 12. Screw length, mm Refer to all Contract Documents for secondary components. Secondary components are elements that are structurally significant for the functions they serve but do not contribute to the overall strength or stability of the primary structural system. Examples include, but are not limited to, the following: a) Site work elements exterior to the base building such as landscaping components, retaining walls, lamp standards, bollards, fences, pools, signs, and civil work. a) Drawings and calculations of components designed by the timber fabricator shall be signed and sealed by the Professional Engineer. The following partially threaded screws with countersunk heads (PSC) are acceptable, unless noted otherwise on the Drawings: SWG SPAX c) 6. PSC 10 x 300 Screw diameter, mm (thread) b) Floor sheathing: 19mm (3/4”) T&G plywood, glued and fastened with 75mm (3”) long common nails at 100mm (4”) o.c. at sheet edges and @ 250mm (10”) o.c. at intermediate supports. millimeters 1. 1. Screw type (see below) 7 SECONDARY COMPONENTS AND THEIR ATTACHMENTS Perform all Work in accordance with CSA O86, Part 9 of the British Columbia Building Code, and Specification Section 06 11 00. a) Studs, joists, built-up posts and beams, nailers, and blocking: 6 CROSS-LAMINATED TIMBER (CLT) PANELS 1. E 10 5 4 7. c) Date of delivery 2) Parallel to joint: ± 50mm min. (100mm total) 3) Vertical: ± 25mm min. (50mm total) C If European glulam is used, all members shall meet the following specifications. Any substitution must have the written approval of the Architect and Consultant. Submit proposed sealer for review and approval. Fichte or Laerche/ Douglasie to EN 14080 b) Stress Grade: GL 28h Min. Supplier responsible to resize member to achieve same performance as specified members. f) Control of width, depth and arrangement of the slots for the HSK-Connection c) Adhesive: EN 14080 g) Moisture content of wood and ambient relative humidity d) Appearance Grade: Commercial where the panel is concealed, Quality elsewhere h) Temperature of the wood members and the HSK-Connectors e) Sealer: Manufacturer’s standard, transparent, compatible with finish e) Dry fitting of HSK-Steel plate ± 50mm min. (100mm total) 20f-Ex a) Species: d) Use-by date 1) Perpendicular to joint: i) Ambient temperature during fabrication and curing of the adhesive j) Theoretical volume of adhesive and actual volume of adhesive injected 8. After end cutting each member to final length, apply a double coat of end sealer to ends and other cross-cut surfaces. 9. For all members on the exterior of the building, provide a shop-applied 13mm (1/2”) thick end cap of matching wood material glued to the end face. Shop apply three coats of sealant to all sides and end caps of members when exposed to rain or moisture. k) Time period between injecting adhesive, placing and arranging the HSK-Connection l) Time of setting of HSK connector into wood member and time of next disturbance of member (movement of member or load change to connector) B 5. J:\2200 - 2249\2248 Whistler Gateway Loop\2248_S1.00, S1.01.dwg 6. Substitutions: Alternative systems may be acceptable if they provide equal performance to the systems shown on the Drawings. Refer to “General” section of these General Notes for alternative proposals. If accepted, the design of alternative systems becomes the responsibility of the Contractor's engineer and will require letters of assurance. Fasteners Used for Erection Purposes: Additional fasteners required for erection purposes are the responsibility of the Contractor and are to be included in the bid. Clearly identify all such fasteners on the shop drawings. 10. Fabricate horizontal members with circular or parabolic camber equal to 1/500 of span. 11. Mark members for identification during erection. Ensure that marks will be concealed from view in final assembly. Clearly mark top surface. 12. See Timber "Fasteners and Connectors" section of these General Notes for requirements related to threaded wood screws and other proprietary connection systems. All accessories are to be painted in accordance with Architect’s specifications or hot dip galvanized prior to shipping to site. See “Structural Steel” section of these General Notes for galvanization requirements. 13. See architectural Drawings for finish requirements. B A A Seal: consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 F (604) 294-2090 E mail@kwl.ca 1 0 Fast +Epp Suite 201 1672 West 1st Ave Vancouver BC Canada V6J 1G1 Rev T 604 731 7412 F 604 731 7620 mail@fastepp.com 2 This drawing is not to be used for construction purposes until noted and dated 'Issued for Construction' All measurements must be checked on site and be verified by the Contractor. Do not scale off hard copy drawings or any electronic/computer files. Written dimensions always have precedent. Hard copy drawings are the official documents for the project and always take precedent over all electronic/computer files. Date Des Dwn Chk 2016-05-31 OB JF NB Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER Copyright reserved. This drawing and design is and at all times remains the exclusive property of Fast+Epp and cannot be used without their written consent and associated disclaimer fees. The information contained herein is for use of the Client only. Fast+Epp is under no obligation to supply electronic/computer files for this project to the Contractor or Subcontractors. Fast+Epp and its employees are not liable to any other parties relating to the use of these drawings. 3 Whistler Gateway Loop Redevelopment GENERAL Project No. Group 4 5 6 2248 N/A NOTES - SHEET 2 Drawing No. Rev. S1.01 7 0 3 2 5 4 SAVED 2016-05-30 1:56 PM 1 6 7 E D 3 554 E E C 3 554 Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm J B A H 3 554 0 370 60 .0 0° G F 0 370 2 554 3 554 1 millimeters 3700 100 3 554 2000 2 D 2000 D 50 5543 EDGE OF RAFT SLAB 1000 x 1000 PEDESTAL TYP. SEE 1C/S4.00 FOR REINF. 1200 20M4000 @350 ADDL. 5-20M4000 @350 T&B ADDL. TYP. AT ALL COL. 3 5-C20M3500 @350 T&B ADDL. TYP. AT ALL COL. 1200 2000 3700 10 0 4 2000 1 S4.00 400 THK CONC. RAFT SLAB: R/W 20M @350 H2E EACH WAY T&B 6 MIL POLY MOISTURE BARRIER ON COMPACTED GRANULAR SUB BASE AS PER GEOTECHNICAL ENGINEERS RECOMMENDATIONS 20M4000 @350 ADDL. 1200 HSS 356 x16 (ASTM A500 OR A1085) STEEL COL., TYP. REDUCE TO HSS 254 x16 (ASTM A500 OR A1085) AT TOP. SEE 1/S4.00 C C 1200 EXIST. SANITARY LINE REFER TO CIVIL DWGS S S S S S S S S S S EXIST. WATER LINE REFER TO CIVIL DWGS B B PLAN NOTES: - REFER TO ARCH AND CIVIL DWGS. FOR SLAB SLOPES AND ELEVATIONS. FOUNDATION PLAN - COORDINATE SLAB AND PEDESTAL ELEVATIONS TO SUIT CAST IN CONDUITS, RISERS, ETC. REFER TO ARCH, CIVIL, AND ELEC. DWGS J:\2200 - 2249\2248 Whistler Gateway Loop\2248_S2.00.dwg 1:100 A A Seal: consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 F (604) 294-2090 E mail@kwl.ca 1 0 Fast +Epp Suite 201 1672 West 1st Ave Vancouver BC Canada V6J 1G1 Rev T 604 731 7412 F 604 731 7620 mail@fastepp.com 2 This drawing is not to be used for construction purposes until noted and dated 'Issued for Construction' All measurements must be checked on site and be verified by the Contractor. Do not scale off hard copy drawings or any electronic/computer files. Written dimensions always have precedent. Hard copy drawings are the official documents for the project and always take precedent over all electronic/computer files. Date Des Dwn Chk 2016-05-31 OB JF NB Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER Copyright reserved. This drawing and design is and at all times remains the exclusive property of Fast+Epp and cannot be used without their written consent and associated disclaimer fees. The information contained herein is for use of the Client only. Fast+Epp is under no obligation to supply electronic/computer files for this project to the Contractor or Subcontractors. Fast+Epp and its employees are not liable to any other parties relating to the use of these drawings. 3 Whistler Gateway Loop Redevelopment FOUNDATION Project No. Group 4 5 6 2248 AS SHOWN PLAN Drawing No. Rev. S2.00 7 0 3 2 5 4 SAVED 2016-05-31 9:52 AM 1 6 7 E D 3 554 E E C 3 554 Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm J B 0 370 G 60 .0 0° A H 3 554 F 0 370 2 554 3 554 1 3 554 3700 100 FOLD LINE B2 1000 TYP. MAX. B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 F S4.13 SIM. C B2 TYP. AT DOUBLE BEAM CONNECTION F S4.13 SIM. B2 B2 B2 TYP. AT COLS. SIM. AT FOLD AND INCLINE B2 A S4.12 B2 A S4.11 B2 B2 B2 1000 TYP. MAX. 4 S4.12 B2 B2 B2 B2 B1 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 TYP. B2 B2 B2 B2 B2 B2 B2 B2 E S4.13 OPP. B2 B 1 TY P . U.N.O . B S4.12 0 100 . Y T P . X MA B2 F S4.13 B2 10 3700 B2 0 B2 B2 B2 C B2 B2 B2 B1 B2 4 B2 3 S4.12 B2 OPP. 1 S4.00 B2 3 B2 B2 0 100 . TYP . X MA B2 TYP. AT INCLINE B2 B2 FOLD LINE B2 B2 2 S4.11 F S4.13 D B2 5543 TYP. AT PREFAB EDGE W/O NOTCH B2 B2 E S4.13 C S4.13 B2 B2 50 A S4.13 B2 2 D TYP. AT PREFAB MID PANEL B S4.13 B2 millimeters TYP. AT PREFAB EDGE W/ NOTCH EDGE OF ROOF PANEL ABOVE, TYP. B B PLAN NOTES: - REFER TO ARCH DWGS. FOR ROOF SLOPES AND ELEVATIONS. ROOF FRAMING PLAN - SOME BEAMS WILL NEED TO BE CUT FROM DEEPER GLULAM SECTIONS TO ACHIEVE DETAILS AT FOLD. SEE S4.10 AND ARCH DWGS. 1:100 J:\2200 - 2249\2248 Whistler Gateway Loop\2248_S2.10.dwg - GLULAM SUPPLIER TO CONFIRM INSTALLED LOCATIONS OF STEEL COLS. WITH CONTRACTOR PRIOR TO FINALIZING GLULAM SHOP DWGS. SEE 1/S4.11. BEAM SCHEDULE MARK A Seal: consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 F (604) 294-2090 E mail@kwl.ca 1 0 Fast +Epp Suite 201 1672 West 1st Ave Vancouver BC Canada V6J 1G1 Rev T 604 731 7412 F 604 731 7620 mail@fastepp.com 2 This drawing is not to be used for construction purposes until noted and dated 'Issued for Construction' All measurements must be checked on site and be verified by the Contractor. Do not scale off hard copy drawings or any electronic/computer files. Written dimensions always have precedent. Hard copy drawings are the official documents for the project and always take precedent over all electronic/computer files. Date Des Dwn Chk 2016-05-31 OB JF NB Description of Revision Rev Date SIZE COMMENT B1 1-130x950 GL SPRUCE / PINE 20f-EX B2 2-130x950 GL SPRUCE / PINE 20f-EX Des Dwn Chk Description of Revision ISSUED FOR TENDER Copyright reserved. This drawing and design is and at all times remains the exclusive property of Fast+Epp and cannot be used without their written consent and associated disclaimer fees. The information contained herein is for use of the Client only. Fast+Epp is under no obligation to supply electronic/computer files for this project to the Contractor or Subcontractors. Fast+Epp and its employees are not liable to any other parties relating to the use of these drawings. 3 A Whistler Gateway Loop Redevelopment ROOF Project No. Group 4 5 6 2248 AS SHOWN FRAMING PLAN Drawing No. Rev. S2.10 7 0 3 2 5 4 SAVED 2016-05-30 1:57 PM 1 6 7 E D 3 554 E E C 3 554 Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm J B 0 370 G 60 .0 0° A H 3 554 F 0 370 2 554 3 554 1 3 554 millimeters 3700 100 FOLD LINE 2 D D 5543 50 FOLD LINE 0 3700 10 3 4 C C EL PAN EL PAN 2 EL PAN 1 EL PAN EL PAN 4 EL PAN 3 EL PAN 7 6 5 B B PLAN NOTES: - SEE DWG. S2.12 FOR LAYOUT OF INDIVIDUAL CLT PANELS WITHIN PREFAB PANELS. ROOF PREFAB PANEL PLAN J:\2200 - 2249\2248 Whistler Gateway Loop\2248_S2.11.dwg 1:100 PROPOSED SEQUENCING: 1st: PANEL 4 2nd: PANEL 3 & 5 3rd: PANEL 2 & 6 4th: PANEL 1 & 7 A A Seal: consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 F (604) 294-2090 E mail@kwl.ca 1 0 Fast +Epp Suite 201 1672 West 1st Ave Vancouver BC Canada V6J 1G1 Rev T 604 731 7412 F 604 731 7620 mail@fastepp.com 2 This drawing is not to be used for construction purposes until noted and dated 'Issued for Construction' All measurements must be checked on site and be verified by the Contractor. Do not scale off hard copy drawings or any electronic/computer files. Written dimensions always have precedent. Hard copy drawings are the official documents for the project and always take precedent over all electronic/computer files. Date Des Dwn Chk 2016-05-31 OB JF NB Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER Copyright reserved. This drawing and design is and at all times remains the exclusive property of Fast+Epp and cannot be used without their written consent and associated disclaimer fees. The information contained herein is for use of the Client only. Fast+Epp is under no obligation to supply electronic/computer files for this project to the Contractor or Subcontractors. Fast+Epp and its employees are not liable to any other parties relating to the use of these drawings. 3 Whistler Gateway Loop Redevelopment ROOF Project No. Group 4 5 6 2248 AS SHOWN PREFAB PANEL PLAN Drawing No. Rev. S2.11 7 0 3 2 5 4 SAVED 2016-05-31 9:35 AM 1 6 7 E D 3 554 E E C 3 554 Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm J B 0 370 G 60 .0 0° A H 3 554 F 2 554 3 554 1 3 554 FOLD LINE 100 245 DP. 7-PLY SPF CLT PANEL (STRUCTURLAM SLT 7 E1M5 OR EQUIVALENT PRE-APPROVED BY FAST+EPP) 3700 millimeters 0 370 SCUPPER, SEE ARCH. 2 D TYP. AT SCUPPER, SEE ARCH DWGS FOR LOCATION D FOLD LINE 5 S4.10 5543 50 8 S4.10 BEAM BELOW, TYP. TYP. AT SINGLE BEAM W/ PANEL JOINT 6 S4.10 4 S4.10 3 TYP. AT SINGLE BEAM 3700 10 2 S4.10 0 TYP. AT DOUBLE BEAM W/ PANEL JOINT 4 1 S4.10 TYP. AT DOUBLE BEAM 6 S4.10 C C 3 S4.10 TYP. AT UNSUPPORTED PANEL JOINTS . EQ 0 300 . EQ . EQ . EQ . EQ . EQ . EQ . EQ . EQ . EQ . EQ 0 300 EL PAN L L I INF . EQ L ANE LP L I INF B B ROOF CLT PANEL PLAN PLAN NOTES: - REFER TO ARCH DWGS. FOR ROOF SLOPES AND ELEVATIONS. J:\2200 - 2249\2248 Whistler Gateway Loop\2248_S2.12.dwg 1:100 A A Seal: consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 F (604) 294-2090 E mail@kwl.ca 1 0 Fast +Epp Suite 201 1672 West 1st Ave Vancouver BC Canada V6J 1G1 Rev T 604 731 7412 F 604 731 7620 mail@fastepp.com 2 This drawing is not to be used for construction purposes until noted and dated 'Issued for Construction' All measurements must be checked on site and be verified by the Contractor. Do not scale off hard copy drawings or any electronic/computer files. Written dimensions always have precedent. Hard copy drawings are the official documents for the project and always take precedent over all electronic/computer files. Date Des Dwn Chk 2016-05-31 OB JF NB Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER Copyright reserved. This drawing and design is and at all times remains the exclusive property of Fast+Epp and cannot be used without their written consent and associated disclaimer fees. The information contained herein is for use of the Client only. Fast+Epp is under no obligation to supply electronic/computer files for this project to the Contractor or Subcontractors. Fast+Epp and its employees are not liable to any other parties relating to the use of these drawings. 3 Whistler Gateway Loop Redevelopment ROOF CLT Project No. Group 4 5 6 2248 AS SHOWN PANEL PLAN Drawing No. Rev. S2.12 7 0 3 2 SAVED 2016-05-31 9:52 AM 1 5 4 6 7 NOTE: SEE GENERAL NOTES FOR GALV. AND TESTING REQUIREMENTS. ℄ CLT PANEL AS PER PLAN E E CP 165 102 375 65 TYP. STIFFENER AND BASE PLATE, SEE 1B/S400 150mmØ HOLE FOR RWL / CONDUIT ASSEMBLY CENTERED MAX. 400 COORD. W/ ARCH. 19 2 - REDUCED COLUMN SECTION CONSTRUCTED WITH PREFAB PANEL 750x750x38mm THK BASE PLATE ℄ 100 1B - HSS COLUMN AS PER PLAN NOTE: - CONTRACTOR TO SURVEY LOCATION OF TOP OF COL. AND PROVIDE LAYOUT TO GLULAM SUPPLIER. NOTIFY FAST+EPP IF AT REST POSITION IS MORE THAN 2mm AWAY FROM THEORETICAL PLAN LOCATION. SECTION 2 - 1:20 NOTE: INSTALL LIGHT RING AFTER FIELD WELDS AND TOUCH UPS COMPLETE. SECTION B - 1:10 LIGHT RING DETAIL 1:5 RWL / CONDUIT ASSEMBLY, SEE MECH. & ELEC. DWGS FINISHED GRADE 450 GALV. 38x38x4.8 FABRICATED ANGLE. CURVED TO MATCH LOWER COL. ANGLE IN TWO SEMI-CIRCLE PIECES. C/W M8x20 @150 MAX. 50 FROM EACH END 12 BEAM AS PER PLAN FINISHED GRADE D 1B - 4 400 MIN. SEE CIVIL 1300 MIN. ℄ CONC. PEDESTAL AS PER PLAN 16mm THK 50MPa NON-SHRINK SEISMIC GROUT 3 ADDL. TIE SETS @75 AT TOP 50 PLATE C/W TAPPED HOLES FOR M8 SCREWS 12 235 25mm THK GUSSET PLATE, TYP. 1D - D LOCATOR RING / BACKER BAR 19 Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm COL. PER PLAN 150 12-32mmØ A490 A.BOLTS HSS COLUMN AS PER PLAN millimeters PEDESTAL PER PLAN INSTALL LIQUID APPLIED MEMBRANE OVER STEEL COLUMN BASE 25x25 LOCATOR RING / BACKER BAR W/ 16x16 CHAMFER 150mmØ HOLE FOR RWL / CONDUIT ASSEMBLY CENTERED ROTATE RWL / CONDUIT BEND TO SUIT COL. ANCHORS CONC. PEDESTAL AS PER PLAN 1C - 40-80 STEEL ASSEMBLY ABOVE BY GLULAM SUPPLIER (INCLUDING FIELD WELD OF REDUCED COL. SECTION TO LOWER CAP PLATE) CP 15M TIE SETS @200 RAFT AS PER PLAN SHIFT TIES AND VERTS TO SUIT STEEL ASSEMBLY BELOW BY STRUCTURAL STEEL SUPPLIER B - 150mmØ HOLE FOR RWL / CONDUIT ASSEMBLY CENTERED 10 50 RAFT AS PER PLAN CP COL PER PLAN 32mm THK PLATE 0 12-32mmØ A490 A.BOLTS 3 - 24-25M VERT. 150mmØ HOLE FOR RWL / CONDUIT ASSEMBLY CENTERED PEDESTAL PER PLAN NOTE: - SEE ALSO 1A/S4.00. - CONTRACTOR TO SURVEY LOCATIONS OF ALL CAST-IN ANCHOR RODS AND PROVIDE LAYOUT TO STEEL FABRICATOR. NOTIFY FAST+EPP IF MODIFICATIONS TO BASE PLATE REQUIRED TO SUIT INSTALLED ANCHOR LOCATIONS. NOTE: - SEE ALSO 1/S4.00. UPPER COL PER PLAN NOTE: - CONTRACTOR TO SURVEY LOCATION OF TOP OF COL. AND PROVIDE LAYOUT TO GLULAM SUPPLIER. NOTIFY FAST+EPP IF AT REST POSITION IS MORE THAN 2mm AWAY FROM THEORETICAL PLAN LOCATION. C C 1 J:\2200 - 2249\2248 Whistler Gateway Loop\2248_S4.0x.dwg S2.00 SECTION 1A - 1:20 SECTION AT RWL / CONDUIT RISER 1C - 1:20 SECTION 1D - 1:20 SECTION 3 - 1:10 SECTION 1:10 B B A A Seal: consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 F (604) 294-2090 E mail@kwl.ca 1 0 Fast +Epp Suite 201 1672 West 1st Ave Vancouver BC Canada V6J 1G1 Rev T 604 731 7412 F 604 731 7620 mail@fastepp.com 2 This drawing is not to be used for construction purposes until noted and dated 'Issued for Construction' All measurements must be checked on site and be verified by the Contractor. Do not scale off hard copy drawings or any electronic/computer files. Written dimensions always have precedent. Hard copy drawings are the official documents for the project and always take precedent over all electronic/computer files. Date Des Dwn Chk 2016-05-31 OB JF NB Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER Copyright reserved. This drawing and design is and at all times remains the exclusive property of Fast+Epp and cannot be used without their written consent and associated disclaimer fees. The information contained herein is for use of the Client only. Fast+Epp is under no obligation to supply electronic/computer files for this project to the Contractor or Subcontractors. Fast+Epp and its employees are not liable to any other parties relating to the use of these drawings. 3 Whistler Gateway Loop Redevelopment SECTIONS Project No. Group 4 5 6 2248 AS SHOWN AND DETAILS Drawing No. Rev. S4.00 7 0 3 2 5 4 6 7 SAVED 2016-05-31 9:52 AM 1 E Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm E VERT. 8x340 PSW @600 EACH BEAM 7 - 100 PAIRS OF INCLINED 8x480 FSZ SCREWS @800 EACH BEAM INSTALLED AT 45° IN OPPOSITE DIRECTION. COUNTERSUNK TO CENTER ON JOINT D PAIRS OF INCLINED 8x480 FSZ SCREWS @800 INSTALLED AT 45° IN OPPOSITE DIRECTION. COUNTERSUNK TO CENTER ON JOINT BEAM AS PER PLAN TAPER EACH PANEL END AS SHOWN FOR TIGHT FIT AT UNDERSIDE FSC 8x240 @600 TYP. @300 ON OVERHANG 35 42 SIM. VERT. 8x340 PSW @600 EACH BEAM 7 - 19mm PLUMB INSTALL AT 45° LOCATE SUCH THAT SCREW CENTERED ON PANEL JOINT. PANEL JOINT PANEL JOINT 50 PAIRS OF INCLINED 8x480 FSZ SCREWS @600 INSTALLED AT 45° IN OPPOSITE DIRECTION. COUNTERSUNK TO CENTER ON JOINT. ALTERNATE PANEL PAIRS OF INCLINED 8x480 FSZ SCREWS @800 EACH BEAM INSTALLED AT 45° IN OPPOSITE DIRECTION. COUNTERSUNK TO CENTER ON JOINT BEAM AS PER PLAN - 10mm BENT PLATE SPLINE RECESSED - USE INCLINED WASHERS FOR INCLINED SCREWS - USE 8x260 INCLINED SCREWS AT 45° TO BISECTING ANGLE BEAM AS PER PLAN PROVIDE VERT. 8-8x580 FSZ IN 2 ROWS (ONE PER PANEL) @100 IN EACH GLULAM AND CLT. COUNTERSINK GLULAM SCREW PER 7/S4.10 D 16 SECTION SECTION 2 1:10 S2.12 3 1:10 S2.12 SECTION SECTION 4 1:10 5 1:10 S2.12 S2.12 SECTION 1:10 0 10 S2.12 SEE SPLINE SECTION 1/FOR SPLINE SIZE AND FASTENING (NOT SHOWN FOR CLARITY) PANEL JOINT 16 1 VERT. 8x340 PSW @600. ALTERNATE PANEL 7 - 3" COMMON NAILS @150 NOTE: AT FOLD LINE USE: PROVIDE VERT. 6-8x580 FSZ IN 2 ROWS @100 IN EACH GLULAM AND CLT. COUNTERSINK GLULAM SCREW PER 7/S4.10 SIM. SEE SPLINE SECTION 1/FOR SPLINE SIZE AND FASTENING (NOT SHOWN FOR CLARITY) 200x25 D.FIR PLY SPLINE 2° PSW 8x120 @600 BEAM AS PER PLAN millimeters VERT. 8x340 PSW @600 7 - C C SEE 4/S4.10 FOR FASTENING SIM. SEE SPLINE DETAIL 1/FOR SPLINE SIZE AND FASTENING (NOT SHOWN FOR CLARITY) 7 - PILOT HOLE AS REQUIRED. MAX 19Ø. HOLE FOR SCUPPER PER ARCH. PAIRS OF INCLINED FSZ SCREWS AT 45° START AT 100 FROM BEAM END CLT PER PLAN VERT. PSW PANEL JOINT B BEAM AS PER PLAN 95 BEAM SIZE ON PLAN IS MIN. DIMENSION OVERSIZE MEMBER AS REQUIRED TO SUIT SLOPED CUT ON TOP SIDE OF BEAM. BLOCKING SHIMS NOT PERMITTED BEAM AS PER PLAN 200Ø MAX. MIN. 400 TO PANEL EDGE, TYP. B VERT. FSC IN CLT AND GLULAM 16 6 J:\2200 - 2249\2248 Whistler Gateway Loop\2248_S4.0x.dwg S2.12 7 SECTION - SECTION SECTION 8 1:10 S2.12 1:10 1:10 A A Seal: consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 F (604) 294-2090 E mail@kwl.ca 1 0 Fast +Epp Suite 201 1672 West 1st Ave Vancouver BC Canada V6J 1G1 Rev T 604 731 7412 F 604 731 7620 mail@fastepp.com 2 This drawing is not to be used for construction purposes until noted and dated 'Issued for Construction' All measurements must be checked on site and be verified by the Contractor. Do not scale off hard copy drawings or any electronic/computer files. Written dimensions always have precedent. Hard copy drawings are the official documents for the project and always take precedent over all electronic/computer files. Date Des Dwn Chk 2016-05-31 OB JF NB Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER Copyright reserved. This drawing and design is and at all times remains the exclusive property of Fast+Epp and cannot be used without their written consent and associated disclaimer fees. The information contained herein is for use of the Client only. Fast+Epp is under no obligation to supply electronic/computer files for this project to the Contractor or Subcontractors. Fast+Epp and its employees are not liable to any other parties relating to the use of these drawings. 3 Whistler Gateway Loop Redevelopment SECTIONS Project No. Group 4 5 6 2248 AS SHOWN AND DETAILS Drawing No. Rev. S4.10 7 0 3 2 SAVED 2016-05-31 9:52 AM 1 5 4 7 ℄ 19mm THK CAP PLATE 19mmØ SCHED 40 STEEL PIPE WELDED IN PLACE. GROUT FILL THRU PIPE UNTIL GROUT COMES OUT AIR HOLES 150mmØ SCHED 40 STEEL PIPE WELDED IN PLACE 12mm AT CLOSEST POINT, TYP. 32mm THK PLATE AIR HOLES BEHIND 3 SIDES TYP. BOT. PLATE 12 8 25mmØ A490 EQUIVALENT TIGHT FIT PIN W/ 3mm CHAMFER AT END. HOLES TO BE MAX 1mm LARGER THAN PIN. 90x200x19mm THK PLATE AT T&B, TYP. TYP. TOP PLATE 8 920x230x25mm THK BEARING PLATE 35 75 10 8 12 E PROVIDE MIN. 50mm RETURN TYP. 12mm AT CLOSEST POINT, TYP. Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm CLT PANEL PER PLAN 1C - A 107 CLR. E . EQ . EQ 16 TIGHT FIT PINS, SEE 1/38 . P TY 356mmØ SECTION, SEE 1/- PROVIDE 200mmØ HOLE IN CLT FOR RWL / CONDUIT ASSEMBLY CENTERED 19mmØ AIR HOLE FOR GROUTING, TYP. U.N.O. 50 BEAM PER PLAN 35 16 35 GLULAM BEAM PER PLAN STEEL ASSEMBLY ABOVE BY GLULAM SUPPLIER (INCLUDING FIELD WELD OF REDUCED COL. SECTION TO LOWER CAP PLATE) 150mmØ HOLE 900x700x5mm THK 350W HSK PLATE, TYP. LAYOUT OF HSK PLATE AS SHOWN. HSK PLATES AND ASSOCIATED STEEL PLATES TO BE SHOP INSTALLED BY GLULAM SUPPLIER, TYP. ADHESIVE PRODUCTS USED ARE TO BE AS DIRECTED BY HSK SUPPLIER. INSTALLATION PROCEDURE AS PER HSK SUPPLIER GUIDELINES AND RECOMMENDATIONS. SEE ALSO GENERAL NOTES FOR FURTHER INFORMATION 1B - D 89x89x12mm THK TRIANGULAR GUSSET PLATE PLUNGE CUT BEAM. DO NOT CUT THROUGH BOT. REDUCED COL. SECTION PER PLAN STEEL ASSEMBLY BELOW BY STRUCTURAL STEEL SUPPLIER HSK PLATE, SEE 1/- 6 BEAM PER PLAN 100x100x12mm THK TRIANGULAR STIFF PLATE (ON DIAGONAL - 6 LOCATIONS) ELEC. CONDUIT EXISTS NEAR BOT. OF REDUCED COL. SECTION. COORD. W/ ARCH. AND ELEC. DWGS 1D S4.00 32mm THK PLATE 10 107 CLR. BEARING PLATE REDUCED COL. SECTION PER PLAN 19mmØ SCHED 40 STEEL PIPE WELDED IN PLACE FOR ELECTRICAL GROUT FILL W/ 50MPa NON-SHRINK GROUT HSK PLATE, SEE 1/- 20 CLR. 25 CP TYP. SLEEVED HOLE FOR ELECTRICAL SLEEVED HOLE FOR GROUTING 75 12 150 HSS 356x16 (A500 OR A1085), TYP. 35 R= 10 50 1 - GLULAM CUT OUT, TYP. D STIFF PLATE BELOW, TYP. 1A 35 16 0 100 STIFF PLATE BELOW, TYP. 400 EDGE OF CLT PANEL 38 38 millimeters 6 0 COL. PER PLAN NOTE: - CONTRACTOR TO SURVEY LOCATION OF TOP OF COL. AND PROVIDE LAYOUT TO GLULAM SUPPLIER. NOTIFY FAST+EPP IF AT REST POSITION IS MORE THAN 2mm AWAY FROM THEORETICAL PLAN LOCATION. - COLD SPRAY GALV. STEEL PINS BEFORE AND IMMEDIATELY AFTER INSTALL W/ 2 COATS OF GALVACON OR APPROVED EQUIVALENT. NOTE: - CLT PANELS NOT SHOWN FOR CLARITY. A S2.10 1 DETAIL - 1:10 SECTION 1A - 1:10 DETAIL 1:10 C C 356mmØ SECTION, SEE 1/STIFF PLATE (ON DIAGONAL), TYP. B B BEARING PLATE REDUCED COL. SECTION PER PLAN SEE ARCH. HOLE W/ STEEL PIPE SLEEVE HSK PLATE, SEE 1/- 400 BEAM PER PLAN J:\2200 - 2249\2248 Whistler Gateway Loop\2248_S4.0x.dwg NOTE: - THIS DETAIL TO BE READ IN CONJUNCTION WITH 1/-. 1B - A DETAIL 2 1:10 S2.10 SECTION A 1:10 Seal: consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 F (604) 294-2090 E mail@kwl.ca 1 0 Fast +Epp Suite 201 1672 West 1st Ave Vancouver BC Canada V6J 1G1 Rev T 604 731 7412 F 604 731 7620 mail@fastepp.com 2 This drawing is not to be used for construction purposes until noted and dated 'Issued for Construction' All measurements must be checked on site and be verified by the Contractor. Do not scale off hard copy drawings or any electronic/computer files. Written dimensions always have precedent. Hard copy drawings are the official documents for the project and always take precedent over all electronic/computer files. Date Des Dwn Chk 2016-05-31 OB JF NB Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER Copyright reserved. This drawing and design is and at all times remains the exclusive property of Fast+Epp and cannot be used without their written consent and associated disclaimer fees. The information contained herein is for use of the Client only. Fast+Epp is under no obligation to supply electronic/computer files for this project to the Contractor or Subcontractors. Fast+Epp and its employees are not liable to any other parties relating to the use of these drawings. 3 Whistler Gateway Loop Redevelopment SECTIONS Project No. Group 4 5 6 2248 AS SHOWN AND DETAILS Drawing No. Rev. S4.11 7 0 3 2 5 4 6 7 SAVED 2016-05-31 9:52 AM 1 ℄ CLT PANEL PER PLAN E Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm EDGE OF CLT ABOVE 178x178x19mm THK PLATE GUSSET PLATE GUSSET PLATE BEHIND 25mmØ A490 EQUIVALENT TIGHT. ENSURE THREADS NOT IN SHEAR PLANE, TYP. 19mmØ A490 THRU BOLT PROVIDE MIN. 50mm RETURN TYP. 90x205x19mm THK PLATE EDGE OF CLT ABOVE 10 150 38 A - GLULAM BEAM PER PLAN CLT ON PREFAB PANEL INSTALLED AFTER GLULAM BEAM PER PLAN TIGHT FIT PINS, SEE 1/BEARING PLATE 150 BEARING PLATE HSK PLATE SEE 1/- HSK PLATE SEE 1/- PLATE BELOW 38 BEAM INSTALLED W/ FIRST PREFAB PANEL 85 CLR. 6 E CLT ON PREFAB PANEL INSTALLED FIRST 920x230x25mm THK BEARING PLATE GLULAM BEAM PER PLAN 16x16 REVEAL, TYP. PLATE BELOW 38 FIELD CONNECT TO BEAM AFTER INSTALL OF THIS PREFAB PANEL THEN INSTALL SPLINE GUSSET PLATE 150 NOTCH CLT PANEL EDGE ABOVE TIGHT AROUND BEAM EDGE TO ACCOMMODATE PREFAB PANEL INSTALLATION 178x125x12mm THK TRIANGULAR GUSSET PLATE 10 50 GLULAM BEAM PER PLAN 50 900x335x3.2mm THK 300W HSK PLATE, TYP. LAYOUT OF HSK PLATE AS SHOWN. HSK PLATES AND ASSOCIATED STEEL PLATES TO BE SHOP INSTALLED BY GLULAM SUPPLIER, TYP. ADHESIVE PRODUCTS USED ARE TO BE AS DIRECTED BY HSK SUPPLIER. INSTALLATION PROCEDURE AS PER HSK SUPPLIER GUIDELINES AND RECOMMENDATIONS. SEE ALSO GENERAL NOTES FOR FURTHER INFORMATION NOTE: - CLT PANELS NOT SHOWN FOR CLARITY. 16x16 REVEAL, TYP. 90x90x12mm THK TRIANGULAR GUSSET PLATE 20 CLR. 5 8 16 1B - OPENING TO BE FILLED W/ MATCHING CLT PANEL AFTER INSTALL OF PINS. FASTEN W/ 2-8x240 FSC INSTALLED AT 45° CENTERED ON JOINT ON TWO OPPOSING SIDES BEAM INSTALLED W/FIRST PREFAB PANEL D PLUNGE CUT BEAM. DO NOT CUT THROUGH BOT. 30x3mm THK COVER STRIP GUSSET PLATE 90x178x19mm THK PLATE 178x178x19mm THK PLATE NOTE: - COLD SPRAY GALV. STEEL PINS BEFORE AND AS POSSIBLE IMMEDIATELY AFTER INSTALL W/ 2 COATS OF GALVACON OR APPROVED EQUIVALENT. 0 10 16 1A - 25 D TYP. WP 1 - 16 178x115x12mm THK GUSSET PLATE 600 190 35 100 70 35 16 8 90x135x12mm THK GUSSET PLATE millimeters 1C - A DETAIL 1 SECTION 1:10 - 1:10 S2.10 1A - SECTION 1B - 1:10 SECTION 1C - 1:10 DETAIL 1:10 C C SEE S4.10 FOR CONNECTION DETAILS SEE S4.10 FOR CONNECTION DETAILS CLT PANELS PER PLAN PANEL CUTS TO BISECT FOLD ANGLE CLT PANELS PER PLAN EDGE OF CLT ABOVE TAPER TOP OF BEAM AS REQUIRED BEAMS TO BE PERPENDICULAR TO PLANE OF CLT PANELS AS SHOWN 250 BEAM PER PLAN B PAIRS OF INCLINED 8x300 FSZ AT 30°, TYP. B PAIRS OF INCLINED SCREWS AND BLOCKING 16mm THK WOOD BLOCKING, TYP. 2 - 250 2-8x300 SFS WT-T INSTALLED AT 45° IN OPPOSITE DIRECTIONS CENTERED ON JOINT. COUNTERSINK AND PLUG, TYP. 1B - 1B - 16 BEAM PER PLAN SIM. J:\2200 - 2249\2248 Whistler Gateway Loop\2248_S4.0x.dwg 2-8x300 SFS WT-T INSTALLED AT 45° IN OPPOSITE DIRECTIONS CENTERED ON JOINT. COUNTERSINK AND PLUG, TYP. 16 16 UNDERSIDE OF BEAMS TO ALIGN. BEAM DEPTH NOTED ON PLAN TO BE THE SMALLEST DIMENSION OF THE SMALLEST MEMBER. BEAMS MEMBERS TO SUIT. ANY CUTS / TAPERS TO BE MADE AT THE TOP OF THE MEMBER BEAM PER PLAN SIM. NOTE: - CLT PANELS NOT SHOWN FOR CLARITY. B S2.10 A DETAIL 2 SECTION 1:10 - 1:10 S2.10 Seal: consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 F (604) 294-2090 E mail@kwl.ca 1 Rev 0 Fast +Epp Suite 201 1672 West 1st Ave Vancouver BC Canada V6J 1G1 SECTION 3 T 604 731 7412 F 604 731 7620 mail@fastepp.com 2 This drawing is not to be used for construction purposes until noted and dated 'Issued for Construction' All measurements must be checked on site and be verified by the Contractor. Do not scale off hard copy drawings or any electronic/computer files. Written dimensions always have precedent. Hard copy drawings are the official documents for the project and always take precedent over all electronic/computer files. 4 1:10 Date S2.10 Des Dwn Chk 2016-05-31 OB JF NB Description of Revision Rev Date Des Dwn Chk SECTION A 1:10 Description of Revision ISSUED FOR TENDER Copyright reserved. This drawing and design is and at all times remains the exclusive property of Fast+Epp and cannot be used without their written consent and associated disclaimer fees. The information contained herein is for use of the Client only. Fast+Epp is under no obligation to supply electronic/computer files for this project to the Contractor or Subcontractors. Fast+Epp and its employees are not liable to any other parties relating to the use of these drawings. 3 Whistler Gateway Loop Redevelopment SECTIONS Project No. Group 4 5 6 2248 AS SHOWN AND DETAILS Drawing No. Rev. S4.12 7 0 3 2 5 4 6 SAVED 2016-05-31 9:52 AM 1 7 CLT PANEL PER PLAN CLT ON PREFAB PANEL INSTALLED FIRST CLT ON PREFAB PANEL INSTALLED AFTER CLT ON PREFAB PANEL INSTALLED FIRST CLT ON PREFAB PANEL INSTALLED AFTER SEE S4.10 FOR FASTENING DETAILS LEAVE CUT-OUT IN CLT DURING PANEL INSTALL. INFILL WITH MATCHING CLT PRIOR TO SPLINE INSTALL. ENSURE CUT-OUT TIGHT TO BEAM EDGE TO ACCOMMODATE PREFAB PANEL INSTALLATION E Paper Size = ARCH D At Full Size, this border measures 570 mm x 850 mm EDGE OF CLT ABOVE EDGE OF CLT ABOVE PAIRS OF INCLINED SCREWS, TYP. PAIRS OF INCLINED SCREWS, TYP. FIELD CONNECT TO BEAM AFTER INSTALL OF THIS PREFAB PANEL THEN INSTALL SPLINE 1 - E EDGE OF CLT ABOVE 16x16 REVEAL, TYP. 1 - 1 - OPP. BEAM INSTALLED W/ FIRST PREFAB PANEL GLULAM BEAM PER PLAN 100 GLULAM BEAM PER PLAN A D 2-8x300 SFS WT-T INSTALLED AT 45° IN OPPOSITE DIRECTIONS CENTERED ON JOINT. COUNTERSINK AND PLUG, TYP. SEE A, B, C / S4.13 FOR PLAN LOCATIONS 1A - NOTE: - CLT PANELS NOT SHOWN FOR CLARITY. DETAIL B 1:10 S2.10 DETAIL C 1:10 S2.10 GLULAM BEAM PER PLAN GLULAM BEAM PER PLAN, TYP. DETAIL 1 SECTION 1:10 - 1:10 1A - SECTION 1:10 D 0 10 50 S2.10 FIELD CONNECT TO BEAM AFTER INSTALL OF THIS PREFAB PANEL THEN INSTALL SPLINE GLULAM BEAM PER PLAN NOTE: - CLT PANELS NOT SHOWN FOR CLARITY. millimeters PAIRS OF INCLINED SCREWS, TYP. BEAM INSTALLED W/ FIRST PREFAB PANEL C C E J:\2200 - 2249\2248 Whistler Gateway Loop\2248_S4.0x.dwg S2.10 DETAIL F 1:10 S2.10 DETAIL 1:10 B B A A Seal: consulting engineers 200 - 4185A Still Creek Drive Burnaby, BC V5C 6G9 T (604) 294-2088 F (604) 294-2090 E mail@kwl.ca 1 0 Fast +Epp Suite 201 1672 West 1st Ave Vancouver BC Canada V6J 1G1 Rev T 604 731 7412 F 604 731 7620 mail@fastepp.com 2 This drawing is not to be used for construction purposes until noted and dated 'Issued for Construction' All measurements must be checked on site and be verified by the Contractor. Do not scale off hard copy drawings or any electronic/computer files. Written dimensions always have precedent. Hard copy drawings are the official documents for the project and always take precedent over all electronic/computer files. Date Des Dwn Chk 2016-05-31 OB JF NB Description of Revision Rev Date Des Dwn Chk Description of Revision ISSUED FOR TENDER Copyright reserved. This drawing and design is and at all times remains the exclusive property of Fast+Epp and cannot be used without their written consent and associated disclaimer fees. The information contained herein is for use of the Client only. Fast+Epp is under no obligation to supply electronic/computer files for this project to the Contractor or Subcontractors. Fast+Epp and its employees are not liable to any other parties relating to the use of these drawings. 3 Whistler Gateway Loop Redevelopment SECTIONS Project No. Group 4 5 6 2248 AS SHOWN AND DETAILS Drawing No. Rev. S4.13 7 0