Variable Volume Diffuser
Transcription
Variable Volume Diffuser
SA2.1/1/EN/1 Variable Volume Diffuser Type XSV - Q and R (Swirl Type) Recommended for room height from 2.6m to 4.0m TROX South Africa (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel: +27 (0) 33 398 1006 Fax: +27 (0) 33 398 1001 Website: www.troxsa.co.za Contents • Description Description Materials and Diffuser Dimensions Selection Data and Maximum Heater limitations Simplified Diffuser layout Controls 2 2 3 3 4 Order Details 5 Description The TROX variable volume flat swirl diffuser is ideal for both comfort air conditioning and industrial applications. The diffuser is for drop-in installation into suspended ceilings. The TROX XSV diffuser is an electronically operated unit incorporating rate aided proportional air volume and heater control. It automatically regulates the room temperature which is measured with a sensor either in the diffuser or in the wall mounted unit. According to the thermal demands in the room the controller moves the damper by means of a push/pull actuator and stainless steel spindle or cycles the heater until the room temperature reaches the set point adjusted on the controller by the user (if wall mounted). Each diffuser has a sub or slave card mounted to the diffuser. The heater is optional. For heater capacities please refer to the table on page 3.The TROX XSV with heater is protected against over-heating (in case there is too little air flow) via an automatic thermal switch (Klixon). This ensures that the surface temperature stays within the safe range required by the SABS. Additionally we can offer a manual Klixon that has to be reset once the surface temperature rises above a certain temperature. The TROX XSV with heater is delivered with a 3m 220V connection cable and a 6m long RJ12 cable to connect the diffusers with each other and with the controller Diffusers are supplied as sub/slave units, these are connected to a single control module and this is connected to a wall mounted finger touch two button thermostat. The transformer is sized according to the number of diffusers connected to a master up to a maximum of 20. The control modules are standalone, LonWorks and BACNet compatible. The thermostat is in an elegant enclosure compatible with a standard 2x4 draw-box. It is supplied with 2 button (MK2) or 3 button (MK3) options. Materials The diffuser body and faceplate are constructed from cold rolled black steel which is all phosphate treated and powdercoated textured white RAL9016. This process will provide corrosion resistance protection to the product based on a 500-hour salt-spray test. Diffuser Dimensions TYPE XSV - Q - D as per page 3 2 Selection Data and Layout Selection Data – Size 600 VAV XSV - Q and R Spigot Total Pressure (Pa) Size D Reading 30 50 70 90 Maximum Heater Capacity (W) 150 FLOW RATE (l/s) THROW (m) N.C. LEVEL 62 1.0 - 91 1.5 26 105 1.7 30 125 2.1 35 750 175 FLOW RATE (l/s) THROW (m) N.C. LEVEL 76 1.2 - 106 1.7 30.5 128 2.1 34 146 2.4 37 1 000 200 FLOW RATE (l/s) THROW (m) N.C. LEVEL 101 1.6 23 135 2.2 33 163 2.5 37 184 2.7 40 1 500 250 FLOW RATE (l/s) THROW (m) N.C. LEVEL 158 1.7 28 194 2.0 33 227 2.3 38 247 2.6 41 1 500 300 FLOW RATE (l/s) THROW (m) N.C. LEVEL 217 2.2 29 272 2.6 34 309 3.0 38 348 3.3 43 1 500 350 FLOW RATE (l/s) THROW (m) N.C. LEVEL 249 2.4 32 315 3.4 34 382 3.9 40 420 4.4 45 1 500 NC levels are determined from sound power level data by deducting 8 dB from each octave band for room attenuation. Throws given are the distance from the diffuser to the point where the jet velocity is reduced to 0.5m/s with the damper in the fully open position. All units with heater will be fitted with auto klixons only as standard. Manual klixons can be fitted as an optional extra. Diagram layout of diffusers type Q and R 3 Plaster Board Installation For installations in plaster board the diffuser is supplied round and can be installed into an installation ring. The installation ring is supplied separate and is fixed by means of “L” brackets to the to the plaster board. Once in place the diffuser lays into the ring, similar to that of a standard ceiling T for the square diffuser. Diffuser Dimensions TYPE XSV - R – D 4 Controls Interface (Wall) Unit Temperature set point Built in room temperature sensor Elegant enclosure fits 2x4 draw-boxes Diagnostic display modes for commissioning and maintenance Master Control (fire retardant ABS) Pre-set temperature set point or use with MK2A81 wall control Inputs for return and supply air temperature Input for occupancy sensor Power Supply to unit: 24V AC Cabling to slave diffusers: 6way RJ12 plugs MMDM-A10 – Stand Alone MMDMLA10 – LON Network MMDMBA10 – BACnet Network MMDMSA10 – Local Network Slave Units Enclosure – aluminium Fitted to each diffuser Cabling: RJ12 between diffuser Order Code Order Code for Stand Alone Order Code for LON Order Code for Bacnet DM - A / 0 or 1 / 0 or 1 / 0 or 1 DM - LA / 0 or 1 / 0 or 1 / 0 or 1 DM - BA / 0 or 1 / 0 or 1 / 0 or 1 0 = no RA sensor 1 = with RA sensor 0 = no auto inverse 1 = with auto inverse 0 = without mount 1 = with mount 0 = no RA sensor 1 = with RA sensor 0 = no auto inverse 1 = with auto inverse 0 = no RA sensor 1 = with RA sensor 0 = without mount 1 = with mount Order Code for Wall Thermostat / Interface 0 = no auto inverse 1 = with auto inverse 0 = without mount 1 = with mount Order Code for Transformer MK2 or MK3 / 0 or 1 T10VA / 0 or 1/ 0 or 1 0 = without 6m cable 1 = with 6m cable MK2 = two button MK3 = three button 0 = without 6 meter cable 1 = with 6 meter cable 10VA = 5 Diffusers 25VA = 10 Diffusers 50VA = 20 Diffusers 0 = without plug top 1 = with plug top Order Code for XPV Diffuser XSV-Q or XSV-R / 1 or 0 / 200 / DSA1 or DSA2 / watts / 0 or 1 or 2 / 1 or 0 / 0 or P1 / RAL… Q = Square R = Round 0 = without ring 1 = with ring Design changes reserved • All rights reserved © TROX South Africa (Pty) Ltd May 2013 DSA1 = without heating DSA2 = with heating Spigot Diam: 150 (148) 175 (173) 200 (198) 250 (248) 300 (298) 350 (348) Element (optional): 0 = None 500 watts 1000 watts 1500 watts P0 = Standard White RAL9016 P0 = Standard White RAL9010 P1 = Powder Coated to RAL… 1 = with 6m cable 0 = without 6m cable 0 = None 1 = auto klixon only 2 = auto and manual Order Example Make:TROX Transformer Details: T25 – VA – 1 – 1 Wall Mounted Thermostat Details: MK2 – 1 Controller Details: DM – A / 0 / 0 / 1 Diffuser Details: XSV - Q / 0 / 250 / DSA2 / 1000w / 1 / 1 / P0 / RAL9016 6