Variable Volume Diffuser

Transcription

Variable Volume Diffuser
SA2.1/1/EN/1
Variable Volume
Diffuser
Type XSV - Q and R (Swirl Type)
Recommended for room height from 2.6m to 4.0m
TROX South Africa (Pty) Ltd.
10 Wigford Road
Masons Mill
Pietermaritzburg
Tel: +27 (0) 33 398 1006
Fax: +27 (0) 33 398 1001
Website: www.troxsa.co.za
Contents • Description
Description
Materials and Diffuser Dimensions
Selection Data and Maximum Heater limitations
Simplified Diffuser layout
Controls
2
2
3
3
4
Order Details
5
Description
The TROX variable volume flat swirl diffuser is ideal for
both comfort air conditioning and industrial applications.
The diffuser is for drop-in installation into suspended ceilings.
The TROX XSV diffuser is an electronically operated unit
incorporating rate aided proportional air volume and heater
control. It automatically regulates the room temperature which
is measured with a sensor either in the diffuser or in the wall
mounted unit.
According to the thermal demands in the
room the controller moves the damper by means of a
push/pull actuator and stainless steel spindle or cycles the
heater until the room temperature reaches the set point
adjusted on the controller by the user (if wall mounted).
Each diffuser has a sub or slave card mounted to the diffuser.
The heater is optional. For heater capacities please refer to
the table on page 3.The TROX XSV with heater is protected
against over-heating (in case there is too little air flow) via an
automatic thermal switch (Klixon).
This ensures that the surface temperature stays within the
safe range required by the SABS. Additionally we can offer a
manual Klixon that has to be reset once the surface
temperature rises above a certain temperature.
The TROX XSV with heater is delivered with a 3m 220V
connection cable and a 6m long RJ12 cable to connect the
diffusers with each other and with the controller
Diffusers are supplied as sub/slave units, these are connected
to a single control module and this is connected to a wall
mounted finger touch two button thermostat. The transformer is
sized according to the number of diffusers connected to a
master up to a maximum of 20.
The control modules are standalone, LonWorks and BACNet
compatible.
The thermostat is in an elegant enclosure compatible with a
standard 2x4 draw-box. It is supplied with 2 button (MK2) or 3
button (MK3) options.
Materials
The diffuser body and faceplate are constructed from cold
rolled black steel which is all phosphate treated and powdercoated textured white RAL9016.
This process will provide corrosion resistance protection to the
product based on a 500-hour salt-spray test.
Diffuser Dimensions TYPE XSV - Q - D as per page 3
2
Selection Data and Layout
Selection Data – Size 600 VAV XSV - Q and R
Spigot Total Pressure (Pa)
Size
D
Reading
30
50
70
90
Maximum
Heater
Capacity
(W)
150
FLOW
RATE
(l/s) THROW (m)
N.C. LEVEL
62
1.0
-
91
1.5
26
105
1.7
30
125
2.1
35
750
175
FLOW
RATE
(l/s) THROW (m)
N.C. LEVEL
76
1.2
-
106
1.7
30.5
128
2.1
34
146
2.4
37
1 000
200
FLOW
RATE
(l/s) THROW (m)
N.C. LEVEL
101
1.6
23
135
2.2
33
163
2.5
37
184
2.7
40
1 500
250
FLOW
RATE
(l/s) THROW (m)
N.C. LEVEL
158
1.7
28
194
2.0
33
227
2.3
38
247
2.6
41
1 500
300
FLOW
RATE
(l/s) THROW (m)
N.C. LEVEL
217
2.2
29
272
2.6
34
309
3.0
38
348
3.3
43
1 500
350
FLOW
RATE
(l/s) THROW (m)
N.C. LEVEL
249
2.4
32
315
3.4
34
382
3.9
40
420
4.4
45
1 500
NC levels are determined from sound power level data by deducting 8 dB from each octave band for room attenuation.
Throws given are the distance from the diffuser to the point where the jet velocity is reduced to 0.5m/s with the damper in the fully
open position.
All units with heater will be fitted with auto klixons only as standard. Manual klixons can be fitted as an optional extra.
Diagram layout of diffusers type Q and R
3
Plaster Board Installation
For installations in plaster board the diffuser is supplied round and can be installed into an installation ring. The
installation ring is supplied separate and is fixed by means of “L” brackets to the to the plaster board. Once in place
the diffuser lays into the ring, similar to that of a standard ceiling T for the square diffuser.
Diffuser Dimensions TYPE XSV - R – D
4
Controls
Interface (Wall) Unit
Temperature set point
Built in room temperature sensor
Elegant enclosure fits 2x4 draw-boxes
Diagnostic display modes for commissioning and maintenance
Master Control (fire retardant ABS)
Pre-set temperature set point or use with MK2A81 wall control
Inputs for return and supply air temperature
Input for occupancy sensor
Power Supply to unit: 24V AC
Cabling to slave diffusers: 6way RJ12 plugs
MMDM-A10 – Stand Alone
MMDMLA10 – LON Network
MMDMBA10 – BACnet Network
MMDMSA10 – Local Network
Slave Units
Enclosure – aluminium
Fitted to each diffuser
Cabling: RJ12 between diffuser
Order Code
Order Code for Stand Alone
Order Code for LON
Order Code for Bacnet
DM - A / 0 or 1 / 0 or 1 / 0 or 1
DM - LA / 0 or 1 / 0 or 1 / 0 or 1
DM - BA / 0 or 1 / 0 or 1 / 0 or 1
0 = no RA sensor
1 = with RA sensor
0 = no auto inverse
1 = with auto inverse
0 = without mount
1 = with mount
0 = no RA sensor
1 = with RA sensor
0 = no auto inverse
1 = with auto inverse
0 = no RA sensor
1 = with RA sensor
0 = without mount
1 = with mount
Order Code for Wall Thermostat / Interface
0 = no auto inverse
1 = with auto inverse
0 = without mount
1 = with mount
Order Code for Transformer
MK2 or MK3 / 0 or 1
T10VA / 0 or 1/ 0 or 1
0 = without 6m cable
1 = with 6m cable
MK2 = two button
MK3 = three button
0 = without 6 meter cable
1 = with 6 meter cable
10VA = 5 Diffusers
25VA = 10 Diffusers
50VA = 20 Diffusers
0 = without plug top
1 = with plug top
Order Code for XPV Diffuser
XSV-Q or XSV-R / 1 or 0 / 200 / DSA1 or DSA2 / watts / 0 or 1 or 2 / 1 or 0 / 0 or P1 / RAL…
Q = Square
R = Round
0 = without ring
1 = with ring
Design changes reserved • All rights reserved © TROX South Africa (Pty) Ltd May 2013
DSA1 = without heating
DSA2 = with heating
Spigot
Diam:
150 (148)
175 (173)
200 (198)
250 (248)
300 (298)
350 (348)
Element
(optional):
0 = None
500 watts
1000 watts
1500 watts
P0 = Standard White RAL9016
P0 = Standard White RAL9010
P1 = Powder Coated to RAL…
1 = with 6m cable
0 = without 6m cable
0 = None
1 = auto klixon only
2 = auto and manual
Order Example
Make:TROX
Transformer
Details: T25 – VA – 1 – 1
Wall Mounted Thermostat
Details: MK2 – 1
Controller
Details: DM – A / 0 / 0 / 1
Diffuser
Details: XSV - Q / 0 / 250 / DSA2 / 1000w / 1 / 1 / P0 / RAL9016
6