NEK 606Offshore-Cables-Catalog

Transcription

NEK 606Offshore-Cables-Catalog
Product Catalog
NEK 606/BFOU/RFOU/BU/RU
Marine, oil, gas and offshore cables
Offshore Cables
Basic Program
IEC / NEK TS 606
Index
NEK 606 Cable types ........................................................................................................................ 3 Halogen-free, mud resistant instrumentation cable RFOU(i) 150/250(300)V, S1/S5 ........................ 4 Halogen-free, mud resistant instrumentation cable RFOU(c) 150/250(300)V, S2/S6 ....................... 8 Halogen-free, mud resistant, fire resistant instrumentation cable BFOU(i) 150/250(300)V, S3/S7 ... 12 Halogen-free, mud resistant, fire resistant instrumentation cable BFOU(c) 150/250(300)V, S4/S8 .. 17 Halogen-free, unarmoured mud resistant instrumentation cable RU(i) 150/250(300)V, S11 ............ 21 Halogen-free, unarmoured mud resistant instrumentation cable RU(c) 150/250(300)V, S12 ........... 24 Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(i)
150/250(300)V, S13 ........................................................................................................................... 27 Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(c)
150/250(300)V, S14 ........................................................................................................................... 30 Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8 .............................................. 33 Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8, large single core cables ....... 40 Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8, double braided ..................... 42 Halogen-free, mud resistant MV power cable, RFOU 3,6/6(7,2)kV, P2/P9 ....................................... 44 Halogen-free, mud resistant MV power cable, RFOU 6/10(12)kV, P3/P10 ....................................... 47 Halogen-free, mud resistant MV power cable, RFOU 8,7/15(17,5)kV, P4/P11 ................................. 50 Halogen-free, mud resistant MV power cable, RFOU 12/20(24)kV, P19/P21 ................................... 53 Halogen-free, mud resistant MV power cable, RFOU 18/30(36)kV, P20/P22 ................................... 56 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12 ...................... 58 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, double
braided ............................................................................................................................................... 66 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, large
single core cables .............................................................................................................................. 69 Halogen-free, mud resistant insulated conductor UX 1000V, P15 .................................................... 71 Halogen-free, fire resistant, unarmoured, mud resistant power cable, BU 0,6/1(1,2)kV, P17 ........... 74 Halogen-free, unarmoured, mud resistant power cable, RU 0,6/1(1,2)kV, P18 ................................ 79 Cable for Variable Frequency Drives (VFD’s), RFOU-VFD 0,6/1(1,8/3)kV with flexible
conductors class 5 and separate earth cores .................................................................................... 85 Cable for Variable Frequency Drives (VFD’s), RFOU-VFD 0,6/1(1,8/3)kV with stranded
conductors class 2 and tinned copper wire braid as earth ................................................................. 88 Fire resistant optical fibre cable, QFCI-I/O/RM-JM/-, F1 ................................................................... 91 Fire resistant optical fibre cable, QFCI-I/O/RM/C-JM/-, MUD PROTECTED (F5) ............................. 93 Flame retardant optical fibre cable, AICI-I/O/RM-W, F6 .................................................................... 95 Flame retardant optical fibre cable, AICI-I/O/RM/C-W, MUD PROTECTED ..................................... 97 Optical fibre data sheet ...................................................................................................................... 99 ICS IE ToughCat 5e S/FTP Installation cable for tougher environments ........................................... 100 ICS IE ToughCat 7 S/FTP Installation cable for tougher environments ............................................. 102 ICS IE ToughCat 7S* S/FTP Installation cable for tougher environments ......................................... 104 ICS IE ToughCat 5e MUD Protected S/FTP Installation cable for tougher environments ................. 106 ICS IE ToughCat 7 MUD Protected S/FTP Installation cable for tougher environments ................... 108 ICS IE ToughCat 7S* MUD Protected S/FTP Installation cable for tougher environments ............... 110 ARCTIC GRADE instrumentation cable RFOU(i) 150/250(300)V, S1/S5 ........................................ 112 ARCTIC GRADE instrumentation cable RFOU(c) 150/250(300)V, S2/S6 ....................................... 116 ARCTIC GRADE Fire resistant, instrumentation cable BFOU(i) 150/250(300)V, S3/S7 .................. 119 ARCTIC GRADE Fire resistant, instrumentation cable BFOU(c) 150/250(300)V, S4/S8 ................. 123 ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8 ................................................................ 127 ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8, large single core cables ........................ 133 ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8, double braided ...................................... 135 Subject to change without prior notice
Page 1 of 212
ARCTIC GRADE Fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12 ...................................... 137 ARCTIC
double braided ............ 143
ARCTIC GRADE
GRADE Fire
Fire resistant
resistant power
power cable,
cable, BFOU
BFOU 0,6/1(1,2)kV,
0,6/1(1,2)kV, P5/P12,
P5/P12 ......................................
137 eXtended
Fire
Resistant,
instrumentation
cable
BFOU-XFR(i)
150/250(300)V
.................................
145 ARCTIC GRADE Fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, double braided ............ 143
eXtended
Fire
Resistant,
instrumentation
cable
BFOU-XFR(c)
150/250(300)V
................................
150
eXtended Fire Resistant, instrumentation cable BFOU-XFR(i) 150/250(300)V ................................. 145 eXtended
steel wire braided ... 150
155 eXtended Fire
Fire Resistant,
Resistant, instrumentation
instrumentation cable
cable BFCU-XFR(i)
BFOU-XFR(c)150/250(300)V,
150/250(300)V ................................
eXtended
Fire
Resistant,
instrumentation
cable
BFCU-XFR(c)
150/250(300)V,
steel
wire
braided
..
eXtended Fire Resistant, instrumentation cable BFCU-XFR(i) 150/250(300)V, steel wire braided ... 160
155 Hydraulic
and
Turbine
oils
resistant,
instrumentation
cable
BFOV(i)
150/250(300)V
........................
165 eXtended Fire Resistant, instrumentation cable BFCU-XFR(c) 150/250(300)V, steel wire braided .. 160
Hydraulic
and
Turbine
oils
resistant,
instrumentation
cable
BFOV(c)
150/250(300)V
.......................
167
Hydraulic and Turbine oils resistant, instrumentation cable BFOV(i) 150/250(300)V ........................ 165 Hydraulic
cable BFOV
0,6/1(1,2)kV
..............................................
Hydraulic and
and Turbine
Turbine oils
oils resistant,
resistant, power
instrumentation
cable
BFOV(c) 150/250(300)V
....................... 170
167 Hydro
Carbon
Fire
Resistant
Cables
.................................................................................................
173
Hydraulic and Turbine oils resistant, power cable BFOV 0,6/1(1,2)kV .............................................. 170 Hydro
Fire Resistant
resistant instrument
cable BFOU-HCF(i) 150/250(300)V, S15 ........................... 176
Hydro Carbon
Carbon Fire
Cables .................................................................................................
173 Hydro
Carbon
Fire
resistant
instrument
cable
BFOU-HCF(c)
150/250(300)V,
S16
..........................
179 Hydro Carbon Fire resistant instrument cable BFOU-HCF(i) 150/250(300)V, S15 ........................... 176
Hydro
Carbon
Fire
resistant
power
cable
BFOU-HCF
0,6/1(1,2)kV,
P34
..........................................
181 Hydro Carbon Fire resistant instrument cable BFOU-HCF(c) 150/250(300)V, S16 .......................... 179
Hydro
Carbon
Fire
resistant
MV
power
cable
RFOU-HCF
6/10(12)kV,
P30
.....................................
186
Hydro Carbon Fire resistant power cable BFOU-HCF 0,6/1(1,2)kV, P34 .......................................... 181 Hydro
............................... 189
Hydro Carbon
Carbon Fire
Fire resistant
resistant MV
MV power
power cable
cable RFOU-HCF
RFOU-HCF 8,7/15(17,5)kV,
6/10(12)kV, P30P31
.....................................
186 Approvals
...........................................................................................................................................
191 Hydro Carbon Fire resistant MV power cable RFOU-HCF 8,7/15(17,5)kV, P31 ............................... 189
Standards
and
tests
...........................................................................................................................
Approvals ........................................................................................................................................... 192
191 Definition
of
terms
..............................................................................................................................
Standards and tests ........................................................................................................................... 194
192 Fire,
flame,
smoke
and
corrosion
test
methods
.................................................................................
195 Definition of terms .............................................................................................................................. 194
Installation
recommendations
............................................................................................................
197
Fire, flame, smoke and corrosion test methods ................................................................................. 195 Electrical
....................................................................................................................................
Installationdata
recommendations
............................................................................................................ 198
197 Material
properties
.............................................................................................................................
207 Electrical data .................................................................................................................................... 198
SHF1
versus
SHF2
............................................................................................................................
209 Material properties ............................................................................................................................. 207
Core
colours
for
cables
according
to
NEK
TS
606
............................................................................
210
SHF1 versus SHF2 ............................................................................................................................ 209 Drum
capacityforincables
metersaccording
....................................................................................................................
211 Core colours
to NEK TS 606 ............................................................................ 210
Code
for cables
.............................................................................................................. 212
Drum designation
capacity in meters
....................................................................................................................
211 Code designation for cables .............................................................................................................. 212 Subject to change without prior notice
Page 2 of 212
Subject to change without prior notice
Page 2 of 212
NEK 606 Cable types
List of all the cable types listed in NEK 606 : NEK 2004 Third Edition
NEK TS 606 Code
NEK TS 606 Description
Draka Norsk Kabel’s
cable type
Power cables LV
and MV
P1
P1 / P8
P2
P2 / P9
P3
P3/P10
P4
P4/P11
P5
P5/P12
P6
P6/P13
P7
P7/P14
P15
P16
P17
P18
P19
P19/P21
P20
P20/P22
P30
P31
P32
P33
P34
RFOU / TFOU 0,6/1 kV
RFOU / TFOU 3,6/6(7,2) kV
RFOU / TFOU 6/10(12) kV
RFOU / TFOU 8,7/15(17,5) kV
BFOU 0,6/1 kV
BFOU 3,6/6(7,2) kV
BFOU 6/10(12) kV
UX 0,6/1 kV
IFLI 250V
BU 0,6/1 kV
RU 0,6/1 kV
RFOU / TFOU 12/20(24) kV
RFOU / TFOU 18/30(36) kV
RFOU-HCF / TFOU-HCF 6/10(12) kV
RFOU-HCF / TFOU-HCF 8,7/15(17,5) kV
RFOU-HCF / TFOU-HCF 12/20(24) kV
RFOU-HCF / TFOU-HCF 18/30(36) kV
BFOU-HCF 0,6/1 kV
RFOU 0,6/1 kV
RFOU 3,676(7,2) kV
RFOU 6/10(12) kV
RFOU 8,7/15(17,5) kV
BFOU 0,6/1 kV
UX 0,6/1 kV
IFLI 250V
BU 0,6/1 kV
RU 0,6/1 kV
RFOU 12/20(24) kV
RFOU 18/30(36) kV
RFOU-HCF 6/10(12) kV
RFOU-HCF 8,7/15(17,5) kV
RFOU-HCF 12/20(24) kV
RFOU-HCF 18/30(36) kV
BFOU-HCF 0,6/1 kV
Instrumentation
and
telecommunication
cables
S1
S1/S5
S2
S2/S6
S3
S3/S7
S4
S4/S8
S9
S10
S11
S12
S13
S14
S15
S16
RFOU(i) 250V
RFOU(c) 250V
BFOU(i) 250V
BFOU(c) 250V
IYXI(c) 60V
IYOI(c) 60V
RU(i) 250V
RU(c) 250V
BU(i) 250V
BU(c) 250V
BFOU-HCF(i) 250V
BFOU-HCF(c) 250V
RFOU(i) 250V
RFOU(c) 250V
BFOU(i) 250V
BFOU(c) 250V
RU(i) 250V
RU(c) 250V
BU(i) 250V
BU(c) 250V
BFOU-HCF(i) 250V
BFOU-HCF(c) 250V
QFCI
QFCI-HCF
QFCB
AICI
QFCI
QFCI-HCF
QFCI- MUD
AICI
Optical Fibre
Cable
F1
F4
F5
F6
Cable types P8 – P14, P21 – P22, S5 – S8 and F5 are to be mud resistant as per NEK TS 606
Subject to change without prior notice
Page 3 of 212
Halogen-free, mud resistant instrumentation cable RFOU(i) 150/250(300)V, S1/S5
Flame retardant halogen-free instrumentation
cable. Mud resistant
RFOU(i) 150/250(300)V
EPR/EPR/TCWB/EVA
NEK TS 606 CodeS1/S5
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation,
communication, Control and alarm systems in both
EX (Zone 0, 1 & 2)- and safe areas. Meets the
mud resistant requirements in NEK TS 606:2009.
IEC 60092-376 (2003-05)
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
R
Pair / Triple /
Quad twisting
Lay up /
Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and
wrapped with a PETP tape.
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
E.g. "meter" "year" DRAKA 01 RFOU(i) 250V S1/S5 4 PAIR 0,75 mm2 IEC 60092376 IEC 60332-3-22
DRAKA 01 = Draka Norsk Kabel,
Grey or Blue
Subject to change without prior notice
Page 4 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
Diameter
inner
covering,
mm
1
1
2
2
2
2
2
2
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
1.1
1.1
1.1
1.1
4
2
0.75
1.1
0.6
1.1
4
2
0.75
1.1
0.6
1.1
8
2
0.75
1.1
0.6
1.1
8
2
0.75
1.1
0.6
1.1
12
2
0.75
1.1
0.6
1.4
12
2
0.75
1.1
0.6
1.4
16
16
19
19
2
2
2
2
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
1.9
1.9
1.9
1.9
7 ± 0.5
7 ± 0.5
10 ± 0.8
10 ± 0.8
11.5 ±
0.8
11.5 ±
0.8
15.5 ±
0.8
15.5 ±
0.8
18.5 ±
0.8
18.5 ±
0.8
21.5 ± 1
21.5 ± 1
22.5 ± 1
22.5 ± 1
24
2
0.75
1.1
0.6
2.1
24
2
0.75
1.1
0.6
1
3
0.75
1.1
1
3
0.75
2
3
2
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
0.2
0.2
0.2
0.2
3.8
3.8
5.3
5.3
1.1
1.1
1.2
1.2
10 ± 0.8
10 ± 0.8
13 ± 0.8
13 ± 0.8
185
185
275
275
54
54
85
85
0.3
10.2
1.3
15 ± 0.8
430
166
0.3
10.2
1.3
15 ± 0.8
430
166
690
265
690
265
19.5 ±
0.8
19.5 ±
0.8
0.3
13.6
1.5
0.3
13.6
1.5
0.3
15.3
1.6
23 ± 1
940
348
0.3
15.3
1.6
23 ± 1
940
348
0.3
0.3
0.3
0.3
17.8
17.8
17.8
17.8
1.7
1.7
1.7
1.7
1240
1240
1360
1360
439
439
489
489
26.5 ± 1
0.3
20.4
1.9
1720
596
2.1
26.5 ± 1
0.3
20.4
1.9
26 ± 1
26 ± 1
27 ± 1
27 ± 1
31.5 ±
1.5
31.5 ±
1.5
1720
596
0.6
1.1
7.5 ± 0.5 0.2
3.8
1.1
200
60
1.1
0.6
1.1
7.5 ± 0.5 0.2
3.8
1.1
200
60
0.75
1.1
0.6
1.1
11 ± 0.8
0.3
8.5
1.3
360
130
3
0.75
1.1
0.6
1.1
11 ± 0.8
0.3
8.5
1.3
360
130
4
3
0.75
1.1
0.6
1.1
0.3
10.2
1.4
510
192
4
3
0.75
1.1
0.6
1.1
8
8
12
12
16
16
19
3
3
3
3
3
3
3
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1.1
1.1
1.4
1.4
2.1
2.1
2.1
24
3
0.75
1.1
0.6
2.5
24
3
0.75
1.1
0.6
2.5
1
1
2
2
1.5
1.5
1.6
1.6
0.7
0.7
2
2
1.5
1.6
2
2
1.5
4
4
8
8
12
12
2
2
2
2
2
2
16
2
12.5 ±
0.8
12.5 ±
0.8
17 ± 0.8
17 ± 0.8
21 ± 1
21 ± 1
24.5 ± 1
24.5 ± 1
25.5 ± 1
30.5 ±
1.5
30.5 ±
1.5
0.3
10.2
1.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
13.6
13.6
17.8
17.8
17.8
17.8
20.4
1.5
1.5
1.7
1.7
1.8
1.8
1.8
10.5 ±
0.8
10.5 ±
0.8
14.5 ±
0.8
14.5 ±
0.8
16.5 ±
0.8
16.5 ±
0.8
21.5 ± 1
21.5 ± 1
25.5 ± 1
25.5 ± 1
29.5 ± 1
29.5 ± 1
30 ± 1.5
0.3
22.9
2
36 ± 1.5
2240
776
0.3
22.9
2
36 ± 1.5
2240
776
1.1
1.1
8 ± 0.5
8 ± 0.5
0.2
0.2
3.8
3.8
1.1
1.1
230
230
71
71
0.7
1.1
12 ± 0.8
0.3
10.2
1.3
420
168
1.6
0.7
1.1
12 ± 0.8
0.3
10.2
1.3
420
168
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
1.1
1.1
1.1
1.1
1.4
1.4
14 ± 0.8
14 ± 0.8
19 ± 0.8
19 ± 0.8
23 ± 1
23 ± 1
0.3
0.3
0.3
0.3
0.3
0.3
11.9
11.9
15.3
15.3
17.8
17.8
1.4
1.4
1.6
1.6
1.8
1.8
600
600
980
980
1380
1380
252
252
420
420
580
580
1.5
1.6
0.7
1.9
26.5 ± 1
0.3
20.4
1.9
11 ± 0.8
11 ± 0.8
15.5 ±
0.8
15.5 ±
0.8
18 ± 0.8
18 ± 0.8
23.5 ± 1
23.5 ± 1
28 ± 1
28 ± 1
31.5 ±
1.5
1830
740
Subject to change without prior notice
510
192
800
800
1160
1160
1540
1540
1720
317
317
450
450
542
542
636
Page 5 of 212
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
Diameter
inner
covering,
mm
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
16
2
1.5
1.6
0.7
1.9
26.5 ± 1
0.3
20.4
1.9
19
2
1.5
1.6
0.7
1.9
27.5 ± 1
0.3
22.9
1.9
19
2
1.5
1.6
0.7
1.9
27.5 ± 1
0.3
22.9
1.9
24
24
32
2
2
2
1.5
1.5
1.5
1.6
1.6
1.6
0.7
0.7
0.7
2.3
2.3
2.4
33 ± 1.5
33 ± 1.5
37 ± 1.5
0.4
0.4
0.4
36.2
36.2
40.7
2.2
2.2
2.3
1
3
1.5
1.6
0.7
1.1
8.5 ± 0.5 0.2
4.5
1.1
1
3
1.5
1.6
0.7
1.1
8.5 ± 0.5 0.2
4.5
1.1
2
3
1.5
1.6
0.7
1.1
0.3
11.9
1.4
4
3
1.5
1.6
0.7
1.1
0.3
13.6
1.5
4
3
1.5
1.6
0.7
1.1
8
8
12
12
16
16
24
24
3
3
3
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.1
1.1
1.4
1.4
2.3
2.3
2.5
2.5
1
2
2.5
2
0.7
1.1
2
2
2.5
2
0.7
1.1
2
2
2.5
2
0.7
1.1
4
2
2.5
2
0.7
1.1
13.5 ±
0.8
15.5 ±
0.8
15.5 ±
0.8
21.5 ± 1
21.5 ± 1
26 ± 1
26 ± 1
31 ± 1.5
31 ± 1.5
38 ± 1.5
38 ± 1.5
9 ± 0.5
13.5 ±
0.8
13.5 ±
0.8
16 ± 0.8
Diameter
outer
sheath,
mm
31.5 ±
1.5
32.5 ±
1.5
32.5 ±
1.5
39 ± 1.5
39 ± 1.5
43 ± 2
11.5 ±
0.8
11.5 ±
0.8
17.5 ±
0.8
20 ± 1
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
1830
740
2040
866
2040
866
2790
2790
3440
1165
1165
1480
260
93
260
93
510
212
740
325
0.3
13.6
1.5
20 ± 1
740
325
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
17.8
17.8
20.4
20.4
22.9
22.9
40.7
40.7
1.7
1.7
1.9
1.9
2
2
2.3
2.3
26 ± 1
26 ± 1
31 ± 1.5
31 ± 1.5
36 ± 1.5
36 ± 1.5
44 ± 2
44 ± 2
1230
1230
1740
1740
2420
2420
3570
3570
557
557
774
774
990
990
1547
1547
0.2
4.5
1.1
280
99
0.3
11.9
1.4
530
225
0.3
11.9
1.4
530
225
0.3
13.6
1.5
12 ± 0.8
17.5 ±
0.8
17.5 ±
0.8
20 ± 1
770
350
Electrical values instrumentation cables
Type
Capacitance, approx. (nF/km)
Inductance, approx, (mH/km)
Resistance at 20°C, max. (Ohm/km)
L/R ratio, (microH/Ohm)
Shielded pair 0,75 mm²
Shielded triple 0,75 mm²
110
110
0,67
0,67
26,3
26,3
12,7
12,7
Shielded pair 1,5 mm²
Shielded triple 1,5 mm²
125
125
0,63
0,63
12,9
12,9
24,4
24,4
Shielded pair 2,5 mm²
Shielded triple 2,5 mm²
145
145
0,59
0,59
8,02
8,02
36,8
36,8
Ordering information
New Part
number
Old Part
number
20110590
20105042
20110591
20110592
20110593
20110849
20110594
20104951
20110850
20131006
892042
892043
892045
892046
20110595
892049
Description
RFOU(I) 1PAIR 0.75mm² S1/S5
RFOU(I) 1PAIR 0.75mm² S1/S5
RFOU(I) 2PAIR 0.75mm² S1/S5
RFOU(I) 2PAIR 0.75mm² S1/S5
RFOU(I) 4PAIR 0.75mm² S1/S5
RFOU(I) 4PAIR 0.75mm² S1/S5
RFOU(I) 8PAIR 0.75mm² S1/S5
RFOU(I) 8PAIR 0.75mm² S1/S5
RFOU(I) 12PAIR 0.75mm² S1/S5
RFOU(I) 12PAIR 0.75mm² S1/S5
RFOU(I) 16PAIR 0.75mm² S1/S5
RFOU(I) 16PAIR 0.75mm² S1/S5
RFOU(I) 19PAIR 0.75mm² S1/S5
RFOU(I) 19PAIR 0.75mm² S1/S5
RFOU(I) 24PAIR 0.75mm² S1/S5
RFOU(I) 24PAIR 0.75mm² S1/S5
Subject to change without prior notice
Sheath Colour
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
Stock item
Yes
Yes
Yes
Yes
Yes
-
EAN No. DNK
7021528920000
7021528920017
7021528920062
7021528920079
7021528920185
7021528920192
7021528920307
7021528920314
7021528920369
7021528920376
7021528920420
7021528920437
7021528920451
7021528920468
7021528920482
7021528920499
EL No.
1044620
1044619
1044621
1044622
1044623
1044624
1044628
1044629
1044630
1044631
1044633
1044632
1044634
1044635
1044636
1044637
Page 6 of 212
New Part
number
Old Part
number
20104949
20110596
20110851
892067
20110852
892079
892090
892091
892096
892097
892102
892103
892106
892108
892109
20110597
20110598
20110599
20111211
20110600
20110601
20110602
20110603
20110604
20110605
20110606
20110607
892245
892246
892248
20110853
892254
20110608
20110609
892266
892278
892279
20110610
892291
892296
892297
892302
892303
892308
892309
20110854
20110855
892407
20110856
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
RFOU(I) 1TRIP 0.75mm² S1/S5
RFOU(I) 1TRIP 0.75mm² S1/S5
RFOU(I) 2TRIP 0.75mm² S1/S5
RFOU(I) 2TRIP 0.75mm² S1/S5
RFOU(I) 4TRIP 0.75mm² S1/S5
RFOU(I) 4TRIP 0.75mm² S1/S5
RFOU(I) 8TRIP 0.75mm² S1/S5
RFOU(I) 8TRIP 0.75mm² S1/S5
RFOU(I) 12TRIP 0.75mm² S1/S5
RFOU(I) 12TRIP 0.75mm² S1/S5
RFOU(I) 16TRIP 0.75mm² S1/S5
RFOU(I) 16TRIP 0.75mm² S1/S5
RFOU(I) 19TRIP 0.75mm² S1/S5
RFOU(I) 24TRIP 0.75mm² S1/S5
RFOU(I) 24TRIP 0.75mm² S1/S5
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
Yes
-
7021528920604
7021528920611
7021528920666
7021528920673
7021528920789
7021528920796
7021528920901
7021528920918
7021528920963
7021528920970
7021528921021
7021528921038
7021528921069
7021528921083
7021528921090
1044690
1044689
1044691
1044692
1044693
1044694
1044697
1044698
1044699
1044700
1044701
1044702
1044707
1044708
RFOU(I) 1PAIR 1.5mm² S1/S5
RFOU(I) 1PAIR 1.5mm² S1/S5
RFOU(I) 2PAIR 1.5mm² S1/S5
RFOU(I) 2PAIR 1.5mm² S1/S5
RFOU(I) 4PAIR 1.5mm² S1/S5
RFOU(I) 4PAIR 1.5mm² S1/S5
RFOU(I) 8PAIR 1.5mm² S1/S5
RFOU(I) 8PAIR 1.5mm² S1/S5
RFOU(I) 12PAIR 1.5mm² S1/S5
RFOU(I) 12PAIR 1.5mm² S1/S5
RFOU(I) 16PAIR 1.5mm² S1/S5
RFOU(I) 16PAIR 1.5mm² S1/S5
RFOU(I) 19PAIR 1.5mm² S1/S5
RFOU(I) 19PAIR 1.5mm² S1/S5
RFOU(I) 24PAIR 1.5mm² S1/S5
RFOU(I) 24PAIR 1.5mm² S1/S5
RFOU(I) 32PAIR 1.5mm² S1/S5
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-
7021528922004
7021528922011
7021528922066
7021528922073
7021528922189
7021528922196
7021528922301
7021528922318
7021528922363
7021528922370
7021528922424
7021528922431
7021528922455
7021528922462
7021528922486
7021528922493
7021528922547
1044460
1044459
1044661
1044662
1044663
1044664
1044668
1044669
1044670
1044671
1044673
1044672
1044674
1044675
1044678
1044679
-
RFOU(I) 1TRIP 1.5mm² S1/S5
RFOU(I) 1TRIP 1.5mm² S1/S5
RFOU(I) 2TRIP 1.5mm² S1/S5
RFOU(I) 4TRIP 1.5mm² S1/S5
RFOU(I) 4TRIP 1.5mm² S1/S5
RFOU(I) 8TRIP 1.5mm² S1/S5
RFOU(I) 8TRIP 1.5mm² S1/S5
RFOU(I) 12TRIP 1.5mm² S1/S5
RFOU(I) 12TRIP 1.5mm² S1/S5
RFOU(I) 16TRIP 1.5mm² S1/S5
RFOU(I) 16TRIP 1.5mm² S1/S5
RFOU(I) 24TRIP 1.5mm² S1/S5
RFOU(I) 24TRIP 1.5mm² S1/S5
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528922608
7021528922615
7021528922660
7021528922783
7021528922790
7021528922905
7021528922912
7021528922967
7021528922974
7021528923025
7021528923032
7021528923087
7021528923094
1044560
1044559
1044762
1044764
1044765
1044768
1044769
1044770
1044771
1044773
1044772
1044779
1044780
RFOU(I) 1PAIR 2.5mm² S1/S5
RFOU(I) 2PAIR 2.5mm² S1/S5
RFOU(I) 2PAIR 2.5mm² S1/S5
RFOU(I) 4PAIR 2.5mm² S1/S5
GREY
GREY
BLUE
GREY
-
7021528924008
7021528924060
7021528924077
7021528924183
-
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 7 of 212
Halogen-free, mud resistant instrumentation cable RFOU(c) 150/250(300)V, S2/S6
Flame retardant halogen-free instrumentation
cable. Mud resistant
RFOU(c) 150/250(300)V
EPR/EPR/TCWB/EVA
NEK TS 606 CodeS2/S6
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
IEC 60092-376 (2003-05)
IEC 60228 class 2
Fixed installation for instrumentation,
IEC 60092-360
communication, Control and alarm systems in both IEC 60092-360
EX (Zone 0, 1 & 2)- and safe areas. Meets the mud IEC 60332-1-2
resistant requirements in NEK TS 606:2009.
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
R
Pair / Triple /
Quad twisting
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
E.g. "meter" "year" DRAKA 01 RFOU(c) 250V S2/S6 8 PAIR 0,75 mm2 IEC 60092376 IEC 60332-3-22
DRAKA 01 = Draka Norsk Kabel,
Grey or Blue
Subject to change without prior notice
Page 8 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
2
2
2
2
0.75
0.75
1.1
1.1
0.6
0.6
1.1
1.1
4
2
0.75
1.1
0.6
1.1
4
2
0.75
1.1
0.6
1.1
8
8
12
12
16
16
19
24
24
2
2
2
2
2
2
2
2
2
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1.1
1.1
1.4
1.4
1.9
1.9
1.9
2.1
2.1
2
2
3
3
0.75
0.75
1.1
1.1
0.6
0.6
1.1
1.1
4
3
0.75
1.1
0.6
1.1
4
3
0.75
1.1
0.6
1.1
8
8
12
12
16
24
24
3
3
3
3
3
3
3
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
2
2
1.5
1.6
2
2
1.5
4
4
2
2
8
2
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
10 ± 0.8
10 ± 0.8
11.5 ±
0.8
11.5 ±
0.8
15 ± 0.8
15 ± 0.8
18 ± 0.8
18 ± 0.8
20.5 ± 1
20.5 ± 1
21.5 ± 1
25 ± 1
25 ± 1
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
0.2
0.2
5.3
5.3
1.2
1.2
13 ± 0.8
13 ± 0.8
270
270
81
81
0.3
8.5
1.3
15 ± 0.8
390
138
0.3
8.5
1.3
15 ± 0.8
390
139
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
11.9
11.9
15.3
15.3
15.3
15.3
17.8
20.4
20.4
1.4
1.4
1.5
1.5
1.6
1.6
1.6
1.8
1.8
19 ± 0.8
19 ± 0.8
22 ± 1
22 ± 1
24.5 ± 1
24.5 ± 1
25.5 ± 1
29.5 ± 1
29.5 ± 1
600
600
820
820
1040
1040
1160
1450
1450
223
223
307
307
358
358
422
510
510
0.2
0.2
5.3
5.3
1.2
1.2
310
310
94
94
0.3
10.2
1.3
14 ± 0.8
14 ± 0.8
16.5 ±
0.8
16.5 ±
0.8
21 ± 1
21 ± 1
24.5 ± 1
24.5 ± 1
27.5 ± 1
33 ± 1.5
33 ± 1.5
470
181
0.3
10.2
1.3
1.1
1.1
1.4
1.4
2.1
2.3
2.3
11 ± 0.8
11 ± 0.8
12.5 ±
0.8
12.5 ±
0.8
17 ± 0.8
17 ± 0.8
20 ± 1
20 ± 1
23 ± 1
28 ± 1
28 ± 1
0.3
0.3
0.3
0.3
0.3
0.3
0.3
13.6
13.6
15.3
15.3
17.8
20.4
20.4
1.5
1.5
1.6
1.6
1.7
1.9
1.9
0.7
1.1
12 ± 0.8
0.3
10.2
1.3
1.6
0.7
1.1
12 ± 0.8
0.3
10.2
1.3
1.5
1.5
1.6
1.6
0.7
0.7
1.1
1.1
0.3
0.3
11.9
11.9
1.5
1.6
0.7
1.1
0.3
15.3
0.3
15.3
1.6
23 ± 1
890
379
0.3
0.3
0.3
0.3
0.3
0.3
0.3
17.8
17.8
17.8
17.8
20.4
20.4
20.4
1.7
1.7
1.7
1.7
1.8
1.8
1.9
25.5 ± 1
25.5 ± 1
26.5 ± 1
26.5 ± 1
29.5 ± 1
29.5 ± 1
31 ± 1.5
36.5 ±
1.5
40 ± 2
40 ± 2
1070
1070
1210
1210
1580
1580
1750
459
459
515
515
651
651
735
2270
924
2890
2890
1252
1252
17 ± 0.8
17 ± 0.8
19.5 ±
0.8
25.5 ± 1
29.5 ± 1
29.5 ± 1
33 ± 1.5
33 ± 1.5
41 ± 2
480
480
190
190
670
290
1130
1560
1560
2080
2080
3110
516
708
708
900
900
1365
181
291
291
384
384
486
664
664
410
162
410
162
1.4
1.4
15.5 ±
0.8
15.5 ±
0.8
18 ± 0.8
18 ± 0.8
560
560
234
234
1.6
23 ± 1
890
379
8
2
1.5
1.6
0.7
1.1
10
10
12
12
16
16
19
2
2
2
2
2
2
2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.2
1.2
1.4
1.4
1.9
1.9
1.9
14 ± 0.8
14 ± 0.8
18.5 ±
0.8
18.5 ±
0.8
21 ± 1
21 ± 1
22 ± 1
22 ± 1
25 ± 1
25 ± 1
26.5 ± 1
24
2
1.5
1.6
0.7
2.3
31 ± 1.5
0.3
25.4
2.1
32
32
2
2
1.5
1.5
1.6
1.6
0.7
0.7
2.4
2.4
34 ± 1.5
34 ± 1.5
0.4
0.4
36.2
36.2
2.2
2.2
2
2
3
3
1.5
1.5
1.6
1.6
0.7
0.7
1.1
1.1
0.3
0.3
10.2
10.2
1.4
1.4
4
3
1.5
1.6
0.7
1.1
0.3
11.9
1.4
8
12
12
16
16
24
3
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
1.1
1.4
1.4
2.1
2.1
2.5
13 ± 0.8
13 ± 0.8
15.5 ±
0.8
21 ± 1
24.5 ± 1
24.5 ± 1
28 ± 1
28 ± 1
35 ± 1.5
0.3
0.3
0.3
0.3
0.3
0.4
17.8
20.4
20.4
22.9
22.9
36.2
1.7
1.8
1.8
1.9
1.9
2.2
Subject to change without prior notice
470
740
740
1010
1010
1350
1860
1860
Page 9 of 212
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
35 ± 1.5 0.4
36.2
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
24
3
1.5
1.6
0.7
2.5
2.2
41 ± 2
3110
1365
2
2
2.5
2
0.7
1.1
13.5 ±
0.8
0.3
10.2
1.4
490
200
4
2
2.5
2
0.7
1.1
16 ± 0.8
0.3
11.9
1.4
680
309
4
2
2.5
2
0.7
1.1
16 ± 0.8
0.3
11.9
1.4
680
309
12
2
2.5
2
0.7
2.1
27 ± 1
0.3
20.4
1.8
1740
759
17.5 ±
0.8
19.5 ±
0.8
19.5 ±
0.8
31.5 ±
1.5
Electrical values instrumentation cables
Type
Capacitance, approx. (nF/km)
Inductance, approx, (mH/km)
Resistance at 20°C, max. (Ohm/km)
L/R ratio, (microH/Ohm)
Unshielded pair 0,75 mm²
Unshielded triple 0,75 mm²
100
100
0,67
0,67
26,3
26,3
12,7
12,7
Unshielded pair 1,5 mm²
Unshielded triple 1,5 mm²
110
110
0,63
0,63
12,9
12,9
24,4
24,4
Unshielded pair 2,5 mm²
Unshielded triple 2,5 mm²
125
125
0,59
0,59
8,02
8,02
36,8
36,8
Ordering information
New Part
number
Old Part
number
20110611
20110857
20110612
20110613
20110614
20110772
20110615
892637
20109493
892643
892645
20109494
892649
20110858
20110616
20110859
892679
20120514
892691
892696
892697
892702
892708
892709
20110617
20110618
20110619
20110620
20110621
892831
892834
892835
20110622
892837
20109495
892843
892845
20110860
892854
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
RFOU(C) 2PAIR 0.75mm² S2/S6
RFOU(C) 2PAIR 0.75mm² S2/S6
RFOU(C) 4PAIR 0.75mm² S2/S6
RFOU(C) 4PAIR 0.75mm² S2/S6
RFOU(C) 8PAIR 0.75mm² S2/S6
RFOU(C) 8PAIR 0.75mm² S2/S6
RFOU(C) 12PAIR 0.75mm² S2/S6
RFOU(C) 12PAIR 0.75mm² S2/S6
RFOU(C) 16PAIR 0.75mm² S2/S6
RFOU(C) 16PAIR 0.75mm² S2/S6
RFOU(C) 19PAIR 0.75mm² S2/S6
RFOU(C) 24PAIR 0.75mm² S2/S6
RFOU(C) 24PAIR 0.75mm² S2/S6
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
Yes
Yes
-
7021528926064
7021528926071
7021528926187
7021528926194
7021528926309
7021528926316
7021528926361
7021528926378
7021528926422
7021528926439
7021528926453
7021528926484
7021528926491
1044421
1044422
1044423
1044424
1044428
1044429
1044430
1044431
1044433
1044432
1044434
1044438
1044437
RFOU(C) 2TRIP 0.75mm² S2/S6
RFOU(C) 2TRIP 0.75mm² S2/S6
RFOU(C) 4TRIP 0.75mm² S2/S6
RFOU(C) 4TRIP 0.75mm² S2/S6
RFOU(C) 8TRIP 0.75mm² S2/S6
RFOU(C) 8TRIP 0.75mm² S2/S6
RFOU(C) 12TRIP 0.75mm² S2/S6
RFOU(C) 12TRIP 0.75mm² S2/S6
RFOU(C) 16TRIP 0.75mm² S2/S6
RFOU(C) 24TRIP 0.75mm² S2/S6
RFOU(C) 24TRIP 0.75mm² S2/S6
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
-
7021528926668
7021528926675
7021528926781
7021528926798
7021528926903
7021528926910
7021528926965
7021528926972
7021528927023
7021528927085
7021528927092
1044490
1044491
1044492
1044493
1044496
1044497
1044499
1044500
1044501
1044507
1044508
RFOU(C) 2PAIR 1.5mm² S2/S6
RFOU(C) 2PAIR 1.5mm² S2/S6
RFOU(C) 4PAIR 1.5mm² S2/S6
RFOU(C) 4PAIR 1.5mm² S2/S6
RFOU(C) 8PAIR 1.5mm² S2/S6
RFOU(C) 8PAIR 1.5mm² S2/S6
RFOU(C) 10PAIR 1.5mm² S2/S6
RFOU(C) 10PAIR 1.5mm² S2/S6
RFOU(C) 12PAIR 1.5mm² S2/S6
RFOU(C) 12PAIR 1.5mm² S2/S6
RFOU(C) 16PAIR 1.5mm² S2/S6
RFOU(C) 16PAIR 1.5mm² S2/S6
RFOU(C) 19PAIR 1.5mm² S2/S6
RFOU(C) 24PAIR 1.5mm² S2/S6
RFOU(C) 32PAIR 1.5mm² S2/S6
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY
Yes
Yes
Yes
Yes
-
7021528928068
7021528928075
7021528928181
7021528928198
7021528928303
7021528928310
7021528928341
7021528928358
7021528928365
7021528928372
7021528928426
7021528928433
7021528928457
7021528928488
7021528928549
1044461
1044462
1044463
1044464
1044468
1044469
1044470
1044472
1044473
1044474
1044478
-
Subject to change without prior notice
Page 10 of 212
New Part
number
Old Part
Description
number
892855
RFOU(C) 32PAIR 1.5mm² S2/S6
BLUE
-
7021528928556
-
RFOU(C) 2TRIP 1.5mm² S2/S6
RFOU(C) 2TRIP 1.5mm² S2/S6
RFOU(C) 4TRIP 1.5mm² S2/S6
RFOU(C) 8TRIP 1.5mm² S2/S6
RFOU(C) 12TRIP 1.5mm² S2/S6
RFOU(C) 12TRIP 1.5mm² S2/S6
RFOU(C) 16TRIP 1.5mm² S2/S6
RFOU(C) 16TRIP 1.5mm² S2/S6
RFOU(C) 24TRIP 1.5mm² S2/S6
RFOU(C) 24TRIP 1.5mm² S2/S6
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528928662
7021528928679
7021528928785
7021528928914
7021528928969
7021528928976
7021528929027
7021528929034
7021528929089
7021528929096
1044561
1044563
1044568
1044569
1044570
1044571
1044572
1044577
1044578
RFOU(C) 2PAIR 2.5mm² S2/S6
RFOU(C) 4PAIR 2.5mm² S2/S6
RFOU(C) 4PAIR 2.5mm² S2/S6
RFOU(C) 12PAIR 2.5mm² S2/S6
GREY
GREY
BLUE
GREY
-
7021528930061
7021528930184
7021528930191
7021528930368
-
20110861
892867
892878
892891
892896
892897
892902
892903
892908
892909
893006
20120742
20110862
20110863
Sheath Colour
Stock item
EAN No. DNK
EL No.
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 11 of 212
Halogen-free,
mud
resistant,
fire
resistant
instrumentation
cable
BFOU(i)
150/250(300)V, S3/S7
Fire resistant, flame retardant halogen-free
instrumentation cable. Mud resistant
BFOU(i) 150/250(300)V
MGT/EPR/EPR/TCWB/EVA
NEK TS 606 CodeS3/S7
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation,
communication, control and alarm systems in both
EX (Zone 0, 1 & 2)- and safe areas, emergency
and critical systems where requirement for fire
resistance exists. Meets the mud resistant
requirements in NEK TS 606:2009.
IEC 60092-376 (2003-05)
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-1, -2, -21
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Lay up /
Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and
wrapped with a PETP tape.
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
Eg. "meter" "year" DRAKA 01 BFOU(i) 250V S3/S7 16 PAIR 0,75 mm2 FLEX FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC
60332-3-22
DRAKA 01 = Draka Norsk Kabel
Grey or Blue
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
**) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes
Subject to change without prior notice
Page 12 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
1
2
0.75
1.1
0.6
1.1
7.5 ± 0.5 0.2
3.8
1.1
1
2
0.75
1.1
0.6
1.1
7.5 ± 0.5 0.2
3.8
1.1
1
4
0.75
1.1
0.6
1.1
8.5 ± 0.5 0.2
4.5
1.2
2
2
0.75
1.1
0.6
1.1
11 ± 0.8
0.3
10.2
1.3
2
2
0.75
1.1
0.6
1.1
11 ± 0.8
0.3
10.2
1.3
4
2
0.75
1.1
0.6
1.1
0.3
11.9
1.4
4
2
0.75
1.1
0.6
1.1
8
8
12
12
16
16
19
19
2
2
2
2
2
2
2
2
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
24
2
0.75
1.1
24
2
0.75
1
1
3
3
2
0.3
11.9
1.4
1.1
1.1
1.4
1.4
1.9
1.9
1.9
1.9
12.5 ±
0.8
12.5 ±
0.8
17 ± 0.8
17 ± 0.8
20.5 ± 1
20.5 ± 1
24 ± 1
24 ± 1
25 ± 1
25 ± 1
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
15.3
15.3
17.8
17.8
20.4
20.4
20.4
20.4
1.6
1.6
1.7
1.7
1.8
1.8
1.9
1.9
0.6
2.3
30 ± 1.5
0.4
31.7
2.1
1.1
0.6
2.3
30 ± 1.5
0.4
31.7
2.1
0.75
0.75
1.1
1.1
0.6
0.6
1.1
1.1
8 ± 0.5
8 ± 0.5
0.2
0.2
4.5
4.5
1.1
1.1
3
0.75
1.1
0.6
1.1
12 ± 0.8
0.3
10.2
1.4
2
3
0.75
1.1
0.6
1.1
12 ± 0.8
0.3
10.2
1.4
4
3
0.75
1.1
0.6
1.1
14 ± 0.8
0.3
11.9
1.4
4
3
0.75
1.1
0.6
1.1
14 ± 0.8
0.3
11.9
1.4
8
3
0.75
1.1
0.6
1.1
0.3
17.8
1.7
8
3
0.75
1.1
0.6
1.1
12
12
3
3
0.75
0.75
1.1
1.1
0.6
0.6
16
3
0.75
1.1
16
3
0.75
19
24
24
3
3
3
1
1
2
2
Diameter
outer
sheath,
mm
10.5 ±
0.8
10.5 ±
0.8
12 ± 0.8
14.5 ±
0.8
14.5 ±
0.8
16.5 ±
0.8
16.5 ±
0.8
21.5 ± 1
21.5 ± 1
25 ± 1
25 ± 1
28.5 ± 1
28.5 ± 1
29.5 ± 1
29.5 ± 1
35.5 ±
1.5
35.5 ±
1.5
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
200
54
200
54
250
74
360
133
360
133
490
183
490
183
780
780
1060
1060
1400
1400
1550
1550
283
283
373
373
465
465
514
514
2100
708
2100
708
11 ± 0.8
11 ± 0.8
15.5 ±
0.8
15.5 ±
0.8
17.5 ±
0.8
17.5 ±
0.8
220
220
68
68
410
146
410
146
570
209
570
209
23 ± 1
960
359
0.3
17.8
1.7
23 ± 1
960
359
1.4
1.4
18.5 ±
0.8
18.5 ±
0.8
22.5 ± 1
22.5 ± 1
0.3
0.3
20.4
20.4
1.8
1.8
1310
1310
477
477
0.6
2.1
26.5 ± 1
0.3
22.9
1.9
1770
594
1.1
0.6
2.1
26.5 ± 1
0.3
22.9
1.9
1770
594
0.75
0.75
0.75
1.1
1.1
1.1
0.6
0.6
0.6
2.3
2.5
2.5
28 ± 1
33 ± 1.5
33 ± 1.5
0.3
0.4
0.4
22.9
36.2
36.2
2
2.2
2.2
27.5 ± 1
27.5 ± 1
31.5 ±
1.5
31.5 ±
1.5
33 ± 1.5
39 ± 1.5
39 ± 1.5
2000
2630
2630
663
909
909
2
2
2
2
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
1.1
1.1
1.1
1.1
0.2
0.2
0.3
0.3
4.5
4.5
11.9
11.9
1.2
1.2
1.4
1.4
79
79
184
184
2
1.5
1.6
0.7
1.1
0.3
13.6
1.5
670
269
4
2
1.5
1.6
0.7
1.1
0.3
13.6
1.5
670
269
8
8
12
2
2
2
1.5
1.5
1.5
1.6
1.6
1.6
0.7
0.7
0.7
1.1
1.1
1.4
0.3
0.3
0.3
17.8
17.8
20.4
1.7
1.7
1.9
12 ± 0.8
12 ± 0.8
17 ± 0.8
17 ± 0.8
19.5 ±
0.8
19.5 ±
0.8
25.5 ± 1
25.5 ± 1
30.5 ±
260
260
470
470
4
9 ± 0.5
9 ± 0.5
13 ± 0.8
13 ± 0.8
15.5 ±
0.8
15.5 ±
0.8
21 ± 1
21 ± 1
25.5 ± 1
1090
1090
1530
446
446
606
Subject to change without prior notice
Page 13 of 212
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
1.5
30.5 ±
1.5
35 ± 1.5
35 ± 1.5
36.5 ±
1.5
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
1530
606
2060
2060
766
766
2440
998
12
2
1.5
1.6
0.7
1.4
25.5 ± 1
0.3
20.4
1.9
16
16
2
2
1.5
1.5
1.6
1.6
0.7
0.7
2.1
2.1
30 ± 1.5
30 ± 1.5
0.3
0.3
22.9
22.9
2
2
19
2
1.5
1.6
0.7
2.1
31 ± 1.5
0.4
36.2
2.1
24
2
1.5
1.6
0.7
2.3
0.4
40.7
2.3
43 ± 2
3080
1211
24
2
1.5
1.6
0.7
2.3
0.4
40.7
2.3
43 ± 2
3080
1211
1
3
1.5
1.6
0.7
1.1
9.5 ± 0.5 0.2
4.5
1.2
290
93
1
3
1.5
1.6
0.7
1.1
9.5 ± 0.5 0.2
4.5
1.2
290
93
2
3
1.5
1.6
0.7
1.1
11.9
1.5
550
213
2
3
1.5
1.6
0.7
1.1
4
4
8
8
3
3
3
3
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
12
3
1.5
1.6
12
3
1.5
1.6
36.5 ±
1.5
36.5 ±
1.5
0.3
11.9
1.5
1.1
1.1
1.1
1.1
14.5 ±
0.8
14.5 ±
0.8
17 ± 0.8
17 ± 0.8
22.5 ± 1
22.5 ± 1
0.3
0.3
0.3
0.3
15.3
15.3
20.4
20.4
1.6
1.6
1.8
1.8
0.7
1.6
28.5 ± 1
0.3
22.9
2
0.7
1.6
28.5 ± 1
0.3
22.9
2
0.4
36.2
2.2
0.4
36.2
0.4
0.4
16
3
1.5
1.6
0.9
2.3
16
3
1.5
1.6
0.9
2.3
24
24
3
3
1.5
1.5
1.6
1.6
0.9
0.9
2.7
2.7
1
1
2
2
2.5
2.5
2
2
0.7
0.7
1.1
1.1
2
2
2.5
2
0.7
1.1
4
8
2
2
2.5
2.5
2
2
0.7
0.7
12
2
2.5
2
16
2
2.5
1
3
8
12
36.5 ±
1.5
36.5 ±
1.5
45.5 ± 2
45.5 ± 2
0.3
12.5 ±
0.8
12.5 ±
0.8
18.5 ±
0.8
18.5 ±
0.8
21 ± 1
21 ± 1
27 ± 1
27 ± 1
33.5 ±
1.5
33.5 ±
1.5
550
213
820
820
1370
1370
342
342
584
584
1970
802
1970
802
42.5 ± 2
3060
1125
2.2
42.5 ± 2
3060
1125
45.2
45.2
2.5
2.5
52 ± 2.5
52 ± 2.5
4400
4400
1598
1598
0.2
0.2
4.5
4.5
1.2
1.2
13 ± 0.8
13 ± 0.8
18.5 ±
0.8
21.5 ± 1
28 ± 1
35.5 ±
1.5
300
300
99
99
560
225
830
1390
367
633
2170
874
3040
1222
350
129
1820
844
2940
1284
0.3
11.9
1.5
1.1
1.1
9.5 ± 0.5
9.5 ± 0.5
14.5 ±
0.8
17 ± 0.8
23.5 ± 1
0.3
0.3
15.3
20.4
1.6
1.8
0.7
2.3
30 ± 1.5
0.3
22.9
2
2
0.9
2.3
36.5 ±
1.5
0.4
36.2
2.2
2.5
2
0.7
1.1
10.5 ±
0.8
0.2
5.3
1.2
3
2.5
2
0.7
1.3
25.5 ± 1
0.3
22.9
2
3
2.5
2
0.7
2.6
33.5 ±
1.5
0.4
36.2
2.2
42.5 ± 2
13.5 ±
0.8
30.5 ±
1.5
39.5 ±
1.5
Electrical values instrumentation cables
Type
Shielded pair 0,75 mm²
Shielded triple 0,75 mm²
Shielded pair 1,5 mm²
Shielded triple 1,5 mm²
Shielded pair 2,5 mm²
Shielded triple 2,5 mm²
Shielded 16 and 24 triple 1,5 mm²
Shielded 16 pair 2,5 mm²
Subject to change without prior notice
Capacitance, approx.
(nF/km)
110
110
125
125
145
145
105
110
Inductance, approx,
(mH/km)
0,67
0,67
0,63
0,63
0,59
0,59
0,71
0,66
Resistance at 20°C, max.
(Ohm/km)
26,3
26,3
12,9
12,9
8,02
8,02
12,9
8,02
L/R ratio,
(microH/Ohm)
12,7
12,7
24,4
24,4
36,8
36,8
24,4
41,1
Page 14 of 212
Ordering information
New Part
number
Old Part
number
20110623
20110624
20110625
20110626
20104969
20110627
20110628
20109496
20110773
20110629
20110630
20110631
20110632
893245
893246
20110633
893249
20110634
20110635
20110636
20110864
20111212
20110865
20110637
20112240
20110878
893297
20110774
893303
893305
20131938
893309
20110638
20110639
20110640
20111213
20110641
20110642
20110643
20110644
20110645
20110646
20109497
20109498
893445
20109499
20109500
20110647
20110648
20110866
893467
20109501
20117428
20110649
20117424
20109502
893497
20109503
893503
893508
893509
20110650
20110867
893606
20110868
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
BFOU(I) 1PAIR 0.75mm² S3/S7
BFOU(I) 1PAIR 0.75mm² S3/S7
BFOU(I) 1QUAD 0.75mm² S3/S7
BFOU(I) 2PAIR 0.75mm² S3/S7
BFOU(I) 2PAIR 0.75mm² S3/S7
BFOU(I) 4PAIR 0.75mm² S3/S7
BFOU(I) 4PAIR 0.75mm² S3/S7
BFOU(I) 8PAIR 0.75mm² S3/S7
BFOU(I) 8PAIR 0.75mm² S3/S7
BFOU(I) 12PAIR 0.75mm² S3/S7
BFOU(I) 12PAIR 0.75mm² S3/S7
BFOU(I) 16PAIR 0.75mm² S3/S7
BFOU(I) 16PAIR 0.75mm² S3/S7
BFOU(I) 19PAIR 0.75mm² S3/S7
BFOU(I) 19PAIR 0.75mm² S3/S7
BFOU(I) 24PAIR 0.75mm² S3/S7
BFOU(I) 24PAIR 0.75mm² S3/S7
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-
7021528932003
7021528932010
7021528932034
7021528932065
7021528932072
7021528932188
7021528932195
7021528932300
7021528932317
7021528932362
7021528932379
7021528932423
7021528932430
7021528932454
7021528932461
7021528932485
7021528932492
1043820
1043819
1044020
1044019
1044021
1044022
1044028
1044029
1044030
1044031
1044033
1044034
1044036
1044037
BFOU(I) 1TRIP 0.75mm² S3/S7
BFOU(I) 1TRIP 0.75mm² S3/S7
BFOU(I) 2TRIP 0.75mm² S3/S7
BFOU(I) 2TRIP 0.75mm² S3/S7
BFOU(I) 4TRIP 0.75mm² S3/S7
BFOU(I) 4TRIP 0.75mm² S3/S7
BFOU(I) 8TRIP 0.75mm² S3/S7
BFOU(I) 8TRIP 0.75mm² S3/S7
BFOU(I) 12TRIP 0.75mm² S3/S7
BFOU(I) 12TRIP 0.75mm² S3/S7
BFOU(I) 16TRIP 0.75mm² S3/S7
BFOU(I) 16TRIP 0.75mm² S3/S7
BFOU(I) 19TRIP 0.75mm² S3/S7
BFOU(I) 24TRIP 0.75mm² S3/S7
BFOU(I) 24TRIP 0.75mm² S3/S7
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
Yes
-
7021528932607
7021528932614
7021528932669
7021528932676
7021528932782
7021528932799
7021528932904
7021528932911
7021528932966
7021528932973
7021528933024
7021528933031
7021528933055
7021528933086
7021528933093
1043920
1043919
1044121
1044122
1044123
1044124
1044128
1044129
1044130
1044131
1044132
1044138
1044139
BFOU(I) 1PAIR 1.5mm² S3/S7
BFOU(I) 1PAIR 1.5mm² S3/S7
BFOU(I) 2PAIR 1.5mm² S3/S7
BFOU(I) 2PAIR 1.5mm² S3/S7
BFOU(I) 4PAIR 1.5mm² S3/S7
BFOU(I) 4PAIR 1.5mm² S3/S7
BFOU(I) 8PAIR 1.5mm² S3/S7
BFOU(I) 8PAIR 1.5mm² S3/S7
BFOU(I) 12PAIR 1.5mm² S3/S7
BFOU(I) 12PAIR 1.5mm² S3/S7
BFOU(I) 16PAIR 1.5mm² S3/S7
BFOU(I) 16PAIR 1.5mm² S3/S7
BFOU(I) 19PAIR 1.5mm² S3/S7
BFOU(I) 24PAIR 1.5mm² S3/S7
BFOU(I) 24PAIR 1.5mm² S3/S7
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-
7021528934007
7021528934014
7021528934069
7021528934076
7021528934182
7021528934199
7021528934304
7021528934311
7021528934366
7021528934373
7021528934427
7021528934434
7021528934458
7021528934489
7021528934496
1043860
1043859
1044060
1044061
1044063
1044064
1044068
1044069
1044070
1044071
1044073
1044074
1044076
-
BFOU(I) 1TRIP 1.5mm² S3/S7
BFOU(I) 1TRIP 1.5mm² S3/S7
BFOU(I) 2TRIP 1.5mm² S3/S7
BFOU(I) 2TRIP 1.5mm² S3/S7
BFOU(I) 4TRIP 1.5mm² S3/S7
BFOU(I) 4TRIP 1.5mm² S3/S7
BFOU(I) 8TRIP 1.5mm² S3/S7
BFOU(I) 8TRIP 1.5mm² S3/S7
BFOU(I) 12TRIP 1.5mm² S3/S7
BFOU(I) 12TRIP 1.5mm² S3/S7
BFOU(I) 16TRIP 1.5mm² S3/S7
BFOU(I) 16TRIP 1.5mm² S3/S7
BFOU(I) 24TRIP 1.5mm² S3/S7
BFOU(I) 24TRIP 1.5mm² S3/S7
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
Yes
-
7021528934601
7021528934618
7021528934663
7021528934670
7021528934786
7021528934793
7021528934908
7021528934915
7021528934960
7021528934977
7021528935028
7021528935035
7021528935080
7021528935097
1044170
1044169
1044171
1044173
1044174
1044177
1044178
1044179
1044180
1044181
1044182
1044193
1044194
BFOU(I) 1PAIR 2.5mm² S3/S7
BFOU(I) 1PAIR 2.5mm² S3/S7
BFOU(I) 2PAIR 2.5mm² S3/S7
BFOU(I) 4PAIR 2.5mm² S3/S7
GREY
BLUE
GREY
GREY
Yes
-
7021528936001
7021528936018
7021528936063
7021528936186
1044140
-
Subject to change without prior notice
Page 15 of 212
New Part
number
20109504
Old Part
Description
number
893630 BFOU(I) 8PAIR 2.5mm² S3/S7
893636 BFOU(I) 12PAIR 2.5mm² S3/S7
BFOU(I) 16PAIR 2.5mm² S3/S7
GREY
GREY
GREY
-
7021528936308
7021528936360
7021528936421
-
BFOU(I) 1TRIP 2.5mm² S3/S7
BFOU(I) 8TRIP 2.5mm² S3/S7
BFOU(I) 12TRIP 2.5mm² S3/S7
GREY
GREY
GREY
-
7021528936605
7021528936902
7021528936964
-
20110869
893690
893696
Sheath Colour
Stock item
EAN No. DNK
EL No.
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius
Fixed Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 16 of 212
Halogen-free,
mud
resistant,
fire
resistant
instrumentation
cable
BFOU(c)
150/250(300)V, S4/S8
Fire resistant, flame retardant halogen-free
instrumentation cable. Mud resistant
BFOU(c) 150/250(300)V
MGT/EPR/EPR/TCWB/EVA
NEK TS 606 CodeS4/S8
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
IEC 60092-376 (2003-05)
IEC 60228 class 2
Fixed installation for instrumentation,
communication, control and alarm systems in both IEC 60092-360
IEC 60092-360
EX (Zone 0, 1 & 2)- and safe areas, emergency
IEC 60332-1-2
and critical systems where requirement for fire
IEC 60332-3-22
resistance exists. Meets the mud resistant
IEC 60331-1, -2, -21
requirements in NEK TS 606:2009.
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
Eg. "meter" "year" DRAKA 01 BFOU(c) 250V S4/S8 4 PAIR 0,75 mm2 FLEX FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC
60332-3-22
DRAKA 01 = Draka Norsk Kabel
Grey or Blue
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
**) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes
Subject to change without prior notice
Page 17 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
2
2
0.75
1.1
0.6
1.1
2
2
0.75
1.1
0.6
1.1
4
2
0.75
1.1
0.6
1.1
4
2
0.75
1.1
0.6
1.1
8
2
0.75
1.1
0.6
1.1
8
2
0.75
1.1
0.6
1.1
12
2
0.75
1.1
0.6
1.4
12
2
0.75
1.1
0.6
1.4
16
16
19
2
2
2
0.75
0.75
0.75
1.1
1.1
1.1
0.6
0.6
0.6
24
2
0.75
1.1
24
2
0.75
2
3
2
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
1.9
1.9
1.9
10.5 ±
0.8
10.5 ±
0.8
12.5 ±
0.8
12.5 ±
0.8
16.5 ±
0.8
16.5 ±
0.8
19.5 ±
0.8
19.5 ±
0.8
22 ± 1
22 ± 1
23 ± 1
0.6
2.3
1.1
0.6
0.75
1.1
3
0.75
4
4
3
3
8
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
14.5 ±
0.8
14.5 ±
0.8
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
340
113
340
113
0.3
8.5
1.3
0.3
8.5
1.3
0.3
10.2
1.4
16 ± 0.8
440
155
0.3
10.2
1.4
16 ± 0.8
440
155
0.3
13.6
1.5
20.5 ± 1
680
240
0.3
13.6
1.5
20.5 ± 1
680
240
0.3
15.3
1.6
24 ± 1
910
307
0.3
15.3
1.6
24 ± 1
910
307
0.3
0.3
0.3
17.8
17.8
20.4
1.7
1.7
1.8
1180
1180
1330
383
383
447
27.5 ± 1
0.3
22.9
2
1700
536
2.3
27.5 ± 1
0.3
22.9
2
26.5 ± 1
26.5 ± 1
28 ± 1
32.5 ±
1.5
32.5 ±
1.5
1700
536
0.6
1.1
12 ± 0.8
0.3
10.2
1.3
400
142
1.1
0.6
1.1
12 ± 0.8
0.3
10.2
1.3
0.75
0.75
1.1
1.1
0.6
0.6
1.1
1.1
0.3
0.3
11.9
11.9
3
0.75
1.1
0.6
1.1
0.3
8
3
0.75
1.1
0.6
1.1
12
12
3
3
0.75
0.75
1.1
1.1
0.6
0.6
1.4
1.4
14 ± 0.8
14 ± 0.8
18.5 ±
0.8
18.5 ±
0.8
22 ± 1
22 ± 1
16
3
0.75
1.1
0.6
2.1
16
3
0.75
1.1
0.6
400
142
1.4
1.4
15.5 ±
0.8
15.5 ±
0.8
18 ± 0.8
18 ± 0.8
540
540
197
197
15.3
1.6
23 ± 1
870
308
0.3
15.3
1.6
23 ± 1
870
308
0.3
0.3
17.8
17.8
1.8
1.8
1180
1180
410
410
25.5 ± 1
0.3
20.4
1.9
1580
513
2.1
25.5 ± 1
0.3
20.4
1.9
27 ± 1
27 ± 1
30.5 ±
1.5
30.5 ±
1.5
1580
513
0.4
36.2
2.1
37 ± 1.5
2350
820
440
162
24
3
0.75
1.1
0.6
2.5
31.5 ±
1.5
2
2
1.5
1.6
0.7
1.1
13 ± 0.8
0.3
10.2
1.4
2
2
1.5
1.6
0.7
1.1
13 ± 0.8
0.3
10.2
1.4
4
4
8
8
12
12
2
2
2
2
2
2
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
1.1
1.1
1.1
1.1
1.4
1.4
15 ± 0.8
15 ± 0.8
20 ± 1
20 ± 1
24 ± 1
24 ± 1
0.3
0.3
0.3
0.3
0.3
0.3
11.9
11.9
17.8
17.8
20.4
20.4
1.4
1.4
1.7
1.7
1.8
1.8
16
2
1.5
1.6
0.7
1.9
27 ± 1
0.3
22.9
1.9
16
2
1.5
1.6
0.7
1.9
27 ± 1
0.3
22.9
1.9
0.4
36.2
2.2
0.4
36.2
2.2
0.3
11.9
1.4
24
2
1.5
1.6
0.7
2.3
24
2
1.5
1.6
0.7
2.3
2
3
1.5
1.6
0.7
1.1
Subject to change without prior notice
33.5 ±
1.5
33.5 ±
1.5
14.5 ±
16.5 ±
0.8
16.5 ±
0.8
19 ± 0.8
19 ± 0.8
24.5 ± 1
24.5 ± 1
28.5 ± 1
28.5 ± 1
31.5 ±
1.5
31.5 ±
1.5
39.5 ±
1.5
39.5 ±
1.5
18.5 ±
440
162
600
600
990
990
1350
1350
234
234
404
404
540
540
1750
677
1750
677
2620
1030
2620
1030
540
207
Page 18 of 212
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
2
3
1.5
1.6
0.7
1.1
4
4
8
8
12
12
3
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
1.1
1.1
1.1
1.1
1.4
1.4
16
3
1.5
1.6
0.7
2.3
16
3
1.5
1.6
0.7
2.3
24
3
1.5
1.6
0.7
2.7
2
2
2.5
2
0.7
1.1
4
2
2.5
2
0.7
1.1
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
0.8
14.5 ±
0.3
11.9
0.8
17 ± 0.8 0.3
13.6
17 ± 0.8 0.3
13.6
22.5 ± 1 0.3
17.8
22.5 ± 1 0.3
17.8
27 ± 1
0.3
22.9
27 ± 1
0.3
22.9
31.5 ±
0.4
36.2
1.5
31.5 ±
0.4
36.2
1.5
38.5 ±
0.4
40.7
1.5
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
540
207
1.5
1.5
1.8
1.8
1.9
1.9
0.8
18.5 ±
0.8
21 ± 1
21 ± 1
27 ± 1
27 ± 1
32 ± 1.5
32 ± 1.5
760
760
1270
1270
1750
1750
307
307
516
516
734
734
2.1
37 ± 1.5
2540
1032
2.1
37 ± 1.5
2540
1032
2.4
45 ± 2
3580
1417
1.4
8
2
2.5
2
0.7
1.1
14 ± 0.8
16.5 ±
0.8
22 ± 1
0.3
17.8
1.8
12
2
2.5
2
0.7
2.1
28 ± 1
0.3
22.9
1.9
16
24
2
2
2.5
2.5
2
2
0.9
0.9
2.3
2.7
33 ± 1.5
41 ± 2
0.4
0.4
31.7
40.7
2.1
2.4
27 ± 1
32.5 ±
1.5
39 ± 1.5
47.5 ± 2
4
3
2.5
2
0.7
1.1
0.3
15.3
1.6
23 ± 1
950
435
0.3
20.4
1.9
30 ± 1.5
1620
761
0.4
36.2
2.3
44.5 ± 2
3570
1473
8
3
2.5
2
0.7
1.1
16
3
2.5
2
0.9
2.6
18.5 ±
0.8
25 ± 1
38.5 ±
1.5
0.3
11.9
1.4
18 ± 0.8
530
217
0.3
13.6
1.5
20.5 ± 1
740
325
1230
551
1860
784
2600
3780
1054
1511
Electrical values instrumentation cables
Type
Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm)
Unshielded pair 0,75 mm²
Unshielded triple 0,75 mm²
100
100
0,67
0,67
26,3
26,3
12,7
12,7
Unshielded pair 1,5 mm²
Unshielded triple 1,5 mm²
110
110
0,63
0,63
12,9
12,9
24,4
24,4
Unshielded pair 2,5 mm²
Unshielded triple 2,5 mm²
125
125
0,59
0,59
8,02
8,02
36,8
36,8
Unshielded 16 and 24 pair 2,5 mm²
Unshielded 16 triple 2,5 mm²
95
95
0,66
0,66
8,02
8,02
41,1
41,1
Ordering information
New Part
number
Old Part
number
20110651
20110652
20110653
20110654
20110655
20110656
20110657
20110658
20110659
20110660
893845
20109505
20118235
20110661
893867
20110662
20118161
20110663
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
BFOU(C) 2PAIR 0.75mm² S4/S8
BFOU(C) 2PAIR 0.75mm² S4/S8
BFOU(C) 4PAIR 0.75mm² S4/S8
BFOU(C) 4PAIR 0.75mm² S4/S8
BFOU(C) 8PAIR 0.75mm² S4/S8
BFOU(C) 8PAIR 0.75mm² S4/S8
BFOU(C) 12PAIR 0.75mm² S4/S8
BFOU(C) 12PAIR 0.75mm² S4/S8
BFOU(C) 16PAIR 0.75mm² S4/S8
BFOU(C) 16PAIR 0.75mm² S4/S8
BFOU(C) 19PAIR 0.75mm² S4/S8
BFOU(C) 24PAIR 0.75mm² S4/S8
BFOU(C) 24PAIR 0.75mm² S4/S8
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-
7021528938067
7021528938074
7021528938180
7021528938197
7021528938302
7021528938319
7021528938364
7021528938371
7021528938425
7021528938432
7021528938456
7021528938487
7021528938494
1043821
1043822
1043823
1043824
1043828
1043829
1043830
1043831
1043833
1043834
1043836
1043837
BFOU(C) 2TRIP 0.75mm² S4/S8
BFOU(C) 2TRIP 0.75mm² S4/S8
BFOU(C) 4TRIP 0.75mm² S4/S8
BFOU(C) 4TRIP 0.75mm² S4/S8
BFOU(C) 8TRIP 0.75mm² S4/S8
GREY
BLUE
GREY
BLUE
GREY
-
7021528938661
7021528938678
7021528938784
7021528938791
7021528938906
1043921
1043922
1043924
1043925
1043928
Subject to change without prior notice
Page 19 of 212
New Part Old Part
number
number
20113359
20110664
893897
20110665
893903
893908
EAN No. DNK
EL No.
BFOU(C) 8TRIP 0.75mm² S4/S8
BFOU(C) 12TRIP 0.75mm² S4/S8
BFOU(C) 12TRIP 0.75mm² S4/S8
BFOU(C) 16TRIP 0.75mm² S4/S8
BFOU(C) 16TRIP 0.75mm² S4/S8
BFOU(C) 24TRIP 0.75mm² S4/S8
BLUE
GREY
BLUE
GREY
BLUE
GREY
Yes
-
7021528938913
7021528938968
7021528938975
7021528939026
7021528939033
7021528939088
1043929
1043930
1043931
1043933
1043934
1043936
20110666
20110667
20110668
20110669
20110670
20110671
20110672
20110673
20109506
20109507
20109508
20109509
BFOU(C) 2PAIR 1.5mm² S4/S8
BFOU(C) 2PAIR 1.5mm² S4/S8
BFOU(C) 4PAIR 1.5mm² S4/S8
BFOU(C) 4PAIR 1.5mm² S4/S8
BFOU(C) 8PAIR 1.5mm² S4/S8
BFOU(C) 8PAIR 1.5mm² S4/S8
BFOU(C) 12PAIR 1.5mm² S4/S8
BFOU(C) 12PAIR 1.5mm² S4/S8
BFOU(C) 16PAIR 1.5mm² S4/S8
BFOU(C) 16PAIR 1.5mm² S4/S8
BFOU(C) 24PAIR 1.5mm² S4/S8
BFOU(C) 24PAIR 1.5mm² S4/S8
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
Yes
Yes
Yes
Yes
Yes
Yes
-
7021528940060
7021528940077
7021528940183
7021528940190
7021528940305
7021528940312
7021528940367
7021528940374
7021528940428
7021528940435
7021528940480
7021528940497
1043862
1043861
1043863
1043864
1043868
1043869
1043870
1043871
1043873
1043874
1043876
1043877
BFOU(C) 2TRIP 1.5mm² S4/S8
BFOU(C) 2TRIP 1.5mm² S4/S8
BFOU(C) 4TRIP 1.5mm² S4/S8
BFOU(C) 4TRIP 1.5mm² S4/S8
BFOU(C) 8TRIP 1.5mm² S4/S8
BFOU(C) 8TRIP 1.5mm² S4/S8
BFOU(C) 12TRIP 1.5mm² S4/S8
BFOU(C) 12TRIP 1.5mm² S4/S8
BFOU(C) 16TRIP 1.5mm² S4/S8
BFOU(C) 16TRIP 1.5mm² S4/S8
BFOU(C) 24TRIP 1.5mm² S4/S8
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
Yes
Yes
-
7021528940664
7021528940671
7021528940787
7021528940794
7021528940909
7021528940916
7021528940961
7021528940978
7021528941029
7021528941036
7021528941081
1043971
1043972
1043973
1043974
1043977
1043978
1043979
1043981
1043982
1043987
894248
BFOU(C) 2PAIR 2.5mm² S4/S8
BFOU(C) 4PAIR 2.5mm² S4/S8
BFOU(C) 8PAIR 2.5mm² S4/S8
BFOU(C) 8PAIR 2.5mm² S4/S8
BFOU(C) 12PAIR 2.5mm² S4/S8
BFOU(C) 16PAIR 2.5mm² S4/S8
BFOU(C) 24PAIR 2.5mm² S4/S8
GREY
GREY
GREY
BLUE
GREY
GREY
GREY
-
7021528942064
7021528942187
7021528942309
7021528942316
7021528942361
7021528942422
7021528942484
-
894278
894290
894302
BFOU(C) 4TRIP 2.5mm² S4/S8
BFOU(C) 8TRIP 2.5mm² S4/S8
BFOU(C) 16TRIP 2.5mm² S4/S8
GREY
GREY
GREY
-
7021528942781
7021528942903
7021528943023
-
20110775
894067
20110674
894079
20110675
894091
20109510
894097
20109511
894103
20110776
20110676
20110677
20110678
894231
20122326
20110777
Description
Sheath Colour
Stock item
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 20 of 212
Halogen-free, unarmoured mud resistant instrumentation cable RU(i) 150/250(300)V,
S11
Flame retardant halogen-free instrumentation
cable. Mud resistant
RU(i) 150/250(300)V
EPR/EVA
NEK TS 606 CodeS11
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
IEC 60092-376 (2003-05)
IEC 60228 class 2
Fixed installation for instrumentation,
IEC 60092-360
communication, Control and alarm systems in both IEC 60092-360
EX- (Zone 2) and safe areas. Meets the mud
IEC 60332-1-2
resistant requirements in NEK TS 606:2009.
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
R
Pair / Triple /
Quad twisting
Lay up /
Shielding
Inner covering
Armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
U
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped
with a PETP tape.
No inner covering. (Additional tapes may be applied)
No armour.
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
E.g. "meter" "year" DRAKA 01 RU(i) 250V S11 2 pair 0,75 mm2 IEC 60092-376 IEC
60332-3-22
DRAKA 01 = Draka Norsk Kabel,
Grey or Blue
Subject to change without prior notice
Page 21 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Number of
elements
Cross
Copper content
No of cores
Conductor
Insulation
Thickness Outer Diameter outer Weight of Cable
section core,
Approx.
in element
Diameter, mm Thickness, mm Sheath, mm
sheath, mm
Approx. (Kg/Km)
mm²
(kg/km)
1
1
2
2
4
8
12
16
24
2
2
2
2
2
2
2
2
2
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1
1
1.1
1.1
1.2
1.3
1.4
1.5
1.7
6.5 ± 0.5
6.5 ± 0.5
10 ± 0.8
10 ± 0.8
11.5 ± 0.8
15.5 ± 0.8
18.5 ± 0.8
21 ± 1
25.5 ± 1
85
85
140
140
235
420
590
760
1120
17
17
34
34
67
133
199
265
397
1
2
4
8
12
16
24
3
3
3
3
3
3
3
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1
1.1
1.2
1.4
1.5
1.6
1.8
7 ± 0.5
11 ± 0.8
13 ± 0.8
18 ± 0.8
21 ± 1
23.5 ± 1
29 ± 1
95
175
290
540
770
990
1460
23
46
92
184
276
368
551
1
1
2
2
4
8
12
16
24
2
2
2
2
2
2
2
2
2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1
1
1.2
1.2
1.3
1.5
1.6
1.7
2
8 ± 0.5
8 ± 0.5
12 ± 0.8
12 ± 0.8
14.5 ± 0.8
20 ± 1
23.5 ± 1
26.5 ± 1
32.5 ± 1.5
120
120
215
215
370
690
970
1260
1880
34
34
68
68
136
271
406
541
811
1
2
4
8
16
24
3
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
1
1.3
1.3
1.6
1.9
2.2
8.5 ± 0.5
14 ± 0.8
16 ± 0.8
22.5 ± 1
30 ± 1.5
37 ± 1.5
140
285
470
900
1700
2520
48
96
192
383
765
1148
Electrical values instrumentation cables
Type
Capacitance, approx. (nF/km)
Inductance, approx, (mH/km)
Resistance at 20°C, max. (Ohm/km)
L/R ratio, (microH/Ohm)
Shielded pair 0,75 mm²
Shielded triple 0,75 mm²
110
110
0,67
0,67
26,3
26,3
12,7
12,7
Shielded pair 1,5 mm²
Shielded triple 1,5 mm²
125
125
0,63
0,63
12,9
12,9
24,4
24,4
Shielded pair 2,5 mm²
Shielded triple 2,5 mm²
145
145
0,59
0,59
8,02
8,02
36,8
36,8
Ordering information
New Part
number
Old Part
number
20111817
20109512
895006
20112238
895018
895030
895036
895042
895048
Description
RU(I) 250V 1PAIR 0.75mm² S11
RU(I) 250V 1PAIR 0.75mm² S11
RU(I) 250V 2PAIR 0.75mm² S11
RU(I) 250V 2PAIR 0.75mm² S11
RU(I) 250V 4PAIR 0.75mm² S11
RU(I) 250V 8PAIR 0.75mm² S11
RU(I) 250V 12PAIR 0.75mm² S11
RU(I) 250V 16PAIR 0.75mm² S11
RU(I) 250V 24PAIR 0.75mm² S11
Subject to change without prior notice
Sheath Colour
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY
GREY
GREY
Stock item
-
EAN No. DNK
7021528950007
7021528950014
7021528950069
7021528950076
7021528950182
7021528950304
7021528950366
7021528950427
7021528950489
Page 22 of 212
EL No.
1062100
1062101
1062106
1062107
1062118
1062130
1062136
1062142
1062148
New Part
number
Old Part
number
20112177
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
RU(I) 250V 1TRIP 0.75mm² S11
RU(I) 250V 2TRIP 0.75mm² S11
RU(I) 250V 4TRIP 0.75mm² S11
RU(I) 250V 8TRIP 0.75mm² S11
RU(I) 250V 12TRIP 0.75mm² S11
RU(I) 250V 16TRIP 0.75mm² S11
RU(I) 250V 24TRIP 0.75mm² S11
GREY
GREY
GREY
GREY
GREY
GREY
GREY
-
7021528950601
7021528950663
7021528950786
7021528950908
7021528950960
7021528951028
7021528951080
1062160
1062166
1062178
1062190
1062194
1062196
1062198
895230
895236
895242
895248
RU(I) 250V 1PAIR 1.5mm² S11
RU(I) 250V 1PAIR 1.5mm² S11
RU(I) 250V 2PAIR 1.5mm² S11
RU(I) 250V 2PAIR 1.5mm² S11
RU(I) 250V 4PAIR 1.5mm² S11
RU(I) 250V 8PAIR 1.5mm² S11
RU(I) 250V 12PAIR 1.5mm² S11
RU(I) 250V 16PAIR 1.5mm² S11
RU(I) 250V 24PAIR 1.5mm² S11
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY
GREY
GREY
-
7021528952001
7021528952018
7021528952063
7021528952070
7021528952186
7021528952308
7021528952360
7021528952421
7021528952483
1062200
1062201
1062206
1062207
1062218
1062230
1062236
1062242
1062248
895260
895266
895278
895290
895302
895308
RU(I) 250V 1TRIP 1.5mm² S11
RU(I) 250V 2TRIP 1.5mm² S11
RU(I) 250V 4TRIP 1.5mm² S11
RU(I) 250V 8TRIP 1.5mm² S11
RU(I) 250V 16TRIP 1.5mm² S11
RU(I) 250V 24TRIP 1.5mm² S11
GREY
GREY
GREY
GREY
GREY
GREY
-
7021528952605
7021528952667
7021528952780
7021528952902
7021528953022
7021528953084
1062260
1062266
1062278
1062290
1062296
1062298
895066
895078
895090
895096
895102
895108
895200
895201
20110870
20110871
20110782
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 23 of 212
Halogen-free, unarmoured mud resistant instrumentation cable RU(c) 150/250(300)V,
S12
Flame retardant halogen-free instrumentation
cable. Mud resistant
RU(c) 150/250(300)V
EPR/EVA
NEK TS 606 CodeS12
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
IEC 60092-376 (2003-05)
IEC 60228 class 2
Fixed installation for instrumentation,
IEC 60092-360
communication, Control and alarm systems in both IEC 60092-360
EX- (Zone 2) and safe areas. Meets the mud
IEC 60332-1-2
resistant requirements in NEK TS 606:2009.
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
R
Pair / Triple /
Quad twisting
Inner covering
Armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
U
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
No inner covering. (Additional tapes may be applied)
No armour.
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
E.g. "meter" "year" DRAKA 01 RU(c) 250V S12 2 pair 0,75 mm2 IEC 60092-376
IEC 60332-3-22
DRAKA 01 = Draka Norsk Kabel,
Grey or Blue
Subject to change without prior notice
Page 24 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Number of
elements
Cross
Copper content
No of cores
Conductor
Insulation
Thickness Outer Diameter outer Weight of Cable
section core,
Approx.
in element
Diameter, mm Thickness, mm Sheath, mm
sheath, mm
Approx. (Kg/Km)
mm²
(kg/km)
2
4
4
8
12
16
19
24
2
2
2
2
2
2
2
2
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1.1
1.1
1.1
1.3
1.4
1.5
1.5
1.6
10 ± 0.8
11.5 ± 0.8
11.5 ± 0.8
15.5 ± 0.8
18 ± 0.8
19.5 ± 0.8
20.5 ± 1
24 ± 1
135
195
195
380
510
640
730
910
30
55
55
106
158
209
247
311
2
4
4
8
16
24
3
3
3
3
3
3
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
1.1
1.2
1.2
1.4
1.6
1.8
11 ± 0.8
13 ± 0.8
13 ± 0.8
17.5 ± 0.8
22 ± 1
27 ± 1
170
265
265
490
870
1260
43
81
81
158
311
465
2
4
8
12
12
16
24
2
2
2
2
2
2
2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.2
1.2
1.4
1.6
1.6
1.7
1.9
12 ± 0.8
14 ± 0.8
19.5 ± 0.8
22.5 ± 1
22.5 ± 1
24.5 ± 1
30 ± 1.5
210
320
610
850
850
1080
1550
62
118
229
340
340
452
674
2
4
8
12
16
24
3
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
1.2
1.3
1.5
1.7
1.8
2.1
13.5 ± 0.8
16 ± 0.8
21.5 ± 1
25.5 ± 1
27.5 ± 1
34 ± 1.5
265
430
820
1170
1500
2210
90
174
341
508
676
1011
Electrical values instrumentation cables
Type
Capacitance, approx. (nF/km)
Inductance, approx, (mH/km)
Resistance at 20°C, max. (Ohm/km)
L/R ratio, (microH/Ohm)
Unshielded pair 0,75 mm²
Unshielded triple 0,75 mm²
100
100
0,67
0,67
26,3
26,3
12,7
12,7
Unshielded pair 1,5 mm²
Unshielded triple 1,5 mm²
110
110
0,63
0,63
12,9
12,9
24,4
24,4
Unshielded pair 2,5 mm²
Unshielded triple 2,5 mm²
125
125
0,59
0,59
8,02
8,02
36,8
36,8
Ordering information
New Part
number
Old Part
number
895606
895618
895619
895630
895636
20132983
895645
20132984
895666
20110873
895679
895690
895702
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
RU(C) 250V 2PAIR 0.75mm² S12
RU(C) 250V 4PAIR 0.75mm² S12
RU(C) 250V 4PAIR 0.75mm² S12
RU(C) 250V 8PAIR 0.75mm² S12
RU(C) 250V 12PAIR 0.75mm² S12
RU(C) 250V 16PAIR 0.75mm² S12
RU(C) 250V 19PAIR 0.75mm² S12
RU(C) 250V 24PAIR 0.75mm² S12
GREY
GREY
BLUE
GREY
GREY
GREY
GREY
GREY
-
7021528956061
7021528956184
7021528956191
7021528956306
7021528956368
7021528956429
7021528956450
7021528956481
1062506
1062518
1062530
1062536
1062542
1062545
1062548
RU(C) 250V 2TRIP 0.75mm² S12
RU(C) 250V 4TRIP 0.75mm² S12
RU(C) 250V 4TRIP 0.75mm² S12
RU(C) 250V 8TRIP 0.75mm² S12
RU(C) 250V 16TRIP 0.75mm² S12
GREY
GREY
BLUE
GREY
GREY
-
7021528956665
7021528956788
7021528956795
7021528956900
7021528957020
1062566
1062578
1062590
1062603
Subject to change without prior notice
Page 25 of 212
New Part
number
Old Part
Description
number
895708
RU(C) 250V 24TRIP 0.75mm² S12
20109513
Sheath Colour
Stock item
EAN No. DNK
EL No.
GREY
-
7021528957082
1062608
895818
895830
895836
895837
895842
895848
RU(C) 250V 2PAIR 1.5mm² S12
RU(C) 250V 4PAIR 1.5mm² S12
RU(C) 250V 8PAIR 1.5mm² S12
RU(C) 250V 12PAIR 1.5mm² S12
RU(C) 250V 12PAIR 1.5mm² S12
RU(C) 250V 16PAIR 1.5mm² S12
RU(C) 250V 24PAIR 1.5mm² S12
GREY
GREY
GREY
GREY
BLUE
GREY
GREY
-
7021528958065
7021528958188
7021528958300
7021528958362
7021528958379
7021528958423
7021528958485
1062706
1062718
1062730
1062736
1062737
1062742
1062748
895866
895878
895890
895896
895902
895908
RU(C) 250V 2TRIP 1.5mm² S12
RU(C) 250V 4TRIP 1.5mm² S12
RU(C) 250V 8TRIP 1.5mm² S12
RU(C) 250V 12TRIP 1.5mm² S12
RU(C) 250V 16TRIP 1.5mm² S12
RU(C) 250V 24TRIP 1.5mm² S12
GREY
GREY
GREY
GREY
GREY
GREY
-
7021528958669
7021528958782
7021528958904
7021528958966
7021528959024
7021528959086
1062766
1062778
1062790
1062794
1062796
1062798
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 26 of 212
Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(i)
150/250(300)V, S13
Fire resistant, flame retardant halogen-free
instrumentation cable. Mud resistant
BU(i) 150/250(300)V
MGT/EPR/EVA
NEK TS 606 CodeS13
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
IEC 60092-376 (2003-05)
IEC 60228 class 2
Fixed installation for instrumentation,
communication, control and alarm systems in both IEC 60092-360
IEC 60092-360
EX-(Zone 2) and safe areas, emergency and
IEC 60332-1-2
critical systems where requirement for fire
IEC 60332-3-22
resistance exists. Meets the mud resistant
IEC 60331-1, -2, -21
requirements in NEK TS 606:2009.
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Lay up /
Shielding
Inner covering
Armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
U
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped
with a PETP tape.
No inner covering. (Additional tapes may be applied)
No armour.
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
"meter" "year" DRAKA 01 BU(i) 250V S13 8 PAIR 0,75 mm2 FLEX - FLAME IEC
60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22
DRAKA 01 = Draka Norsk Kabel,
Grey or Blue
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
**) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes
Subject to change without prior notice
Page 27 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Number of
elements
Cross
Copper content
No of cores
Conductor
Insulation
Thickness Outer Diameter outer Weight of Cable
section core,
Approx.
in element
Diameter, mm Thickness, mm Sheath, mm
sheath, mm
Approx. (Kg/Km)
mm²
(kg/km)
1
1
2
2
4
8
12
12
16
24
2
2
2
2
2
2
2
2
2
2
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1
1
1.2
1.2
1.2
1.4
1.6
1.6
1.7
1.9
7.5 ± 0.5
7.5 ± 0.5
11 ± 0.8
11 ± 0.8
13 ± 0.8
17.5 ± 0.8
21 ± 1
21 ± 1
23.5 ± 1
29 ± 1
95
95
165
165
260
490
700
700
900
1300
17
17
34
34
67
133
199
199
265
397
1
2
4
8
12
16
24
3
3
3
3
3
3
3
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1
1.2
1.3
1.5
1.7
1.8
2
7.5 ± 0.5
12 ± 0.8
14 ± 0.8
19.5 ± 0.8
23.5 ± 1
26 ± 1
32 ± 1.5
105
200
340
640
900
1170
1690
23
46
92
184
276
368
552
1
1
2
2
4
4
8
8
12
12
16
24
24
2
2
2
2
2
2
2
2
2
2
2
2
2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1
1
1.3
1.3
1.4
1.4
1.6
1.6
1.7
1.7
1.9
2.2
2.2
8.5 ± 0.5
8.5 ± 0.5
13.5 ± 0.8
13.5 ± 0.8
16 ± 0.8
16 ± 0.8
22 ± 1
22 ± 1
26 ± 1
26 ± 1
29.5 ± 1
36.5 ± 1.5
36.5 ± 1.5
130
130
250
250
420
420
770
770
1100
1100
1440
2120
2120
34
34
68
68
136
136
271
271
406
406
541
812
812
1
1
2
4
8
12
16
24
3
3
3
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.1
1.1
1.3
1.4
1.7
1.9
2
2.4
9.5 ± 0.5
9.5 ± 0.5
14.5 ± 0.8
17.5 ± 0.8
23.5 ± 1
29 ± 1
32.5 ± 1.5
40.5 ± 2
165
165
310
530
1020
1470
1910
2860
48
48
96
192
384
575
767
1150
1
2
2.5
2
0.7
1.1
9.5 ± 0.5
170
55
Electrical values instrumentation cables
Type
Capacitance, approx. (nF/km)
Inductance, approx, (mH/km)
Resistance at 20°C, max. (Ohm/km)
L/R ratio, (microH/Ohm)
Shielded pair 0,75 mm²
Shielded triple 0,75 mm²
110
110
0,67
0,67
26,3
26,3
12,7
12,7
Shielded pair 1,5 mm²
Shielded triple 1,5 mm²
125
125
0,63
0,63
12,9
12,9
24,4
24,4
Shielded pair 2,5 mm²
Shielded triple 2,5 mm²
145
145
0,59
0,59
8,02
8,02
36,8
36,8
Ordering information
New Part
number
Old Part
number
20109514
896201
Description
BU(I) 250V 1PAIR 0.75mm² S13
BU(I) 250V 1PAIR 0.75mm² S13
Subject to change without prior notice
Sheath Colour
GREY
BLUE
Stock item
-
EAN No. DNK
7021528962000
7021528962017
EL No.
1063500
1063501
Page 28 of 212
896206
896207
896218
896230
896236
896237
896242
896248
BU(I) 250V 2PAIR 0.75mm² S13
BU(I) 250V 2PAIR 0.75mm² S13
BU(I) 250V 4PAIR 0.75mm² S13
BU(I) 250V 8PAIR 0.75mm² S13
BU(I) 250V 12PAIR 0.75mm² S13
BU(I) 250V 12PAIR 0.75mm² S13
BU(I) 250V 16PAIR 0.75mm² S13
BU(I) 250V 24PAIR 0.75mm² S13
GREY
BLUE
GREY
GREY
GREY
BLUE
GREY
GREY
-
7021528962062
7021528962079
7021528962185
7021528962307
7021528962369
7021528962376
7021528962420
7021528962482
1063506
1063507
1063518
1063530
1063536
1063542
1063548
896266
896278
896290
896296
896302
896308
BU(I) 250V 1TRIP 0.75mm² S13
BU(I) 250V 2TRIP 0.75mm² S13
BU(I) 250V 4TRIP 0.75mm² S13
BU(I) 250V 8TRIP 0.75mm² S13
BU(I) 250V 12TRIP 0.75mm² S13
BU(I) 250V 16TRIP 0.75mm² S13
BU(I) 250V 24TRIP 0.75mm² S13
GREY
GREY
GREY
GREY
GREY
GREY
GREY
-
7021528962604
7021528962666
7021528962789
7021528962901
7021528962963
7021528963021
7021528963083
1063560
1063566
1063578
1063590
1063596
1063602
1063608
896419
896430
896431
896436
896437
896442
896448
896449
BU(I) 250V 1PAIR 1.5mm² S13
BU(I) 250V 1PAIR 1.5mm² S13
BU(I) 250V 2PAIR 1.5mm² S13
BU(I) 250V 2PAIR 1.5mm² S13
BU(I) 250V 4PAIR 1.5mm² S13
BU(I) 250V 4PAIR 1.5mm² S13
BU(I) 250V 8PAIR 1.5mm² S13
BU(I) 250V 8PAIR 1.5mm² S13
BU(I) 250V 12PAIR 1.5mm² S13
BU(I) 250V 12PAIR 1.5mm² S13
BU(I) 250V 16PAIR 1.5mm² S13
BU(I) 250V 24PAIR 1.5mm² S13
BU(I) 250V 24PAIR 1.5mm² S13
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
-
7021528964004
7021528964011
7021528964066
7021528964073
7021528964189
7021528964196
7021528964301
7021528964318
7021528964363
7021528964370
7021528964424
7021528964486
7021528964493
1063700
1063701
1063706
1063707
1063718
1063730
1063736
1063737
1063742
1063748
-
896460
896461
896466
896478
896490
896496
896502
896508
BU(I) 250V 1TRIP 1.5mm² S13
BU(I) 250V 1TRIP 1.5mm² S13
BU(I) 250V 2TRIP 1.5mm² S13
BU(I) 250V 4TRIP 1.5mm² S13
BU(I) 250V 8TRIP 1.5mm² S13
BU(I) 250V 12TRIP 1.5mm² S13
BU(I) 250V 16TRIP 1.5mm² S13
BU(I) 250V 24TRIP 1.5mm² S13
GREY
BLUE
GREY
GREY
GREY
GREY
GREY
GREY
-
7021528964608
7021528964615
7021528964660
7021528964783
7021528964905
7021528964967
7021528965025
7021528965087
1063760
1063761
1063766
1063778
1063790
1063796
1063802
1063808
896600
BU(I) 250V 1PAIR 2.5mm² S13
GREY
-
7021528966008
1063900
20119107
20109515
20109516
20109517
896407
20109518
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 29 of 212
Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(c)
150/250(300)V, S14
Fire resistant, flame retardant halogen-free
instrumentation cable. Mud resistant
BU(c) 150/250(300)V
MGT/EPR/EVA
NEK TS 606 CodeS14
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
IEC 60092-376 (2003-05)
IEC 60228 class 2
Fixed installation for instrumentation,
communication, control and alarm systems in both IEC 60092-360
IEC 60092-360
EX-(Zone 2) and safe areas, emergency and
IEC 60332-1-2
critical systems where requirement for fire
IEC 60332-3-22
resistance exists. Meets the mud resistant
IEC 60331-1, -2, 21
requirements in NEK TS 606:2009.
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Inner covering
Armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
U
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
No inner covering. (Additional tapes may be applied)
No armour.
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
"meter" "year" DRAKA 01 BU(c) 250V S14 8 PAIR 0,75 mm2 FLEX - FLAME IEC
60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22
DRAKA 01 = Draka Norsk Kabel,
Grey or Blue
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
**) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes
Subject to change without prior notice
Page 30 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Number of
elements
Cross
Copper content
No of cores
Conductor
Insulation
Thickness Outer Diameter outer Weight of Cable
section core,
Approx.
in element
Diameter, mm Thickness, mm Sheath, mm
sheath, mm
Approx. (Kg/Km)
mm²
(kg/km)
2
4
8
12
12
16
19
24
2
2
2
2
2
2
2
2
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1.1
1.2
1.4
1.5
1.5
1.6
1.6
1.8
10.5 ± 0.8
12.5 ± 0.8
17 ± 0.8
19.5 ± 0.8
19.5 ± 0.8
21.5 ± 1
22.5 ± 1
26.5 ± 1
150
230
420
570
570
720
820
1040
30
55
107
158
158
209
247
311
2
4
8
12
16
24
3
3
3
3
3
3
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
1.2
1.3
1.5
1.6
1.7
1.9
12 ± 0.8
14.5 ± 0.8
19.5 ± 0.8
22.5 ± 1
24.5 ± 1
30 ± 1.5
200
310
590
780
1000
1430
43
81
158
235
312
466
2
4
8
12
16
24
2
2
2
2
2
2
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
1.2
1.3
1.5
1.7
1.8
2.1
13 ± 0.8
15.5 ± 0.8
21 ± 1
24.5 ± 1
26.5 ± 1
33 ± 1.5
225
360
660
940
1200
1770
62
118
229
341
452
675
2
4
8
12
16
24
3
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
1.3
1.4
1.6
1.8
1.9
2.2
15 ± 0.8
17.5 ± 0.8
23.5 ± 1
28 ± 1
30.5 ± 1.5
37.5 ± 1.5
310
500
930
1300
1670
2470
90
174
342
509
677
1012
2
2
2.5
2.0
0.7
1.3
14.5 ± 0.8
295
96
Electrical values instrumentation cables
Type
Capacitance, approx. (nF/km)
Inductance, approx, (mH/km)
Resistance at 20°C, max. (Ohm/km)
L/R ratio, (microH/Ohm)
Unshielded pair 0,75 mm²
Unshielded triple 0,75 mm²
100
100
0,67
0,67
26,3
26,3
12,7
12,7
Unshielded pair 1,5 mm²
Unshielded triple 1,5 mm²
110
110
0,63
0,63
12,9
12,9
24,4
24,4
Unshielded pair 2,5 mm²
Unshielded triple 2,5 mm²
125
125
0,59
0,59
8,02
8,02
36,8
36,8
Ordering information
New Part
number
Old Part
number
20110778
20115554
20109519
20119162
896837
20119164
896845
20115190
20109520
20109521
20109522
896896
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
BU(C) 250V 2PAIR 0.75mm² S14
BU(C) 250V 4PAIR 0.75mm² S14
BU(C) 250V 8PAIR 0.75mm² S14
BU(C) 250V 12PAIR 0.75mm² S14
BU(C) 250V 12PAIR 0.75mm² S14
BU(C) 250V 16PAIR 0.75mm² S14
BU(C) 250V 19PAIR 0.75mm² S14
BU(C) 250V 24PAIR 0.75mm² S14
GREY
GREY
GREY
GREY
BLUE
GREY
GREY
GREY
-
7021528968064
7021528968187
7021528968309
7021528968361
7021528968378
7021528968422
7021528968453
7021528968484
1064106
1064118
1064130
1064136
1064142
1064145
1064148
BU(C) 250V 2TRIP 0.75mm² S14
BU(C) 250V 4TRIP 0.75mm² S14
BU(C) 250V 8TRIP 0.75mm² S14
BU(C) 250V 12TRIP 0.75mm² S14
GREY
GREY
GREY
GREY
-
7021528968668
7021528968781
7021528968903
7021528968965
1064166
1064178
1064190
1064196
Subject to change without prior notice
Page 31 of 212
New Part
number
20119166
20109523
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
896908
BU(C) 250V 16TRIP 0.75mm² S14
BU(C) 250V 24TRIP 0.75mm² S14
GREY
GREY
-
7021528969023
7021528969085
1064203
1064208
897006
897018
897030
897036
897042
897048
BU(C) 250V 2PAIR 1.5mm² S14
BU(C) 250V 4PAIR 1.5mm² S14
BU(C) 250V 8PAIR 1.5mm² S14
BU(C) 250V 12PAIR 1.5mm² S14
BU(C) 250V 16PAIR 1.5mm² S14
BU(C) 250V 24PAIR 1.5mm² S14
GREY
GREY
GREY
GREY
GREY
GREY
-
7021528970067
7021528970180
7021528970302
7021528970364
7021528970425
7021528970487
1064306
1064318
1064330
1064336
1064342
1064348
897066
897078
897090
897096
897102
897108
BU(C) 250V 2TRIP 1.5mm² S14
BU(C) 250V 4TRIP 1.5mm² S14
BU(C) 250V 8TRIP 1.5mm² S14
BU(C) 250V 12TRIP 1.5mm² S14
BU(C) 250V 16TRIP 1.5mm² S14
BU(C) 250V 24TRIP 1.5mm² S14
GREY
GREY
GREY
GREY
GREY
GREY
-
7021528970661
7021528970784
7021528970906
7021528970968
7021528971026
7021528971088
1064366
1064378
1064390
1064396
1064402
1064408
BU(C) 250V 2PAIR 2.5mm² S14
GREY
-
7021528972061
-
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 32 of 212
Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8
Flame retardant halogen-free power cable.
Mud resistant
RFOU 0,6/1(1,2)kV
EPR/EPR/TCWB/EVA
NEK TS 606 CodeP1/P8
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
Fixed installation for power,control and lighting in
both EX (Zone 0, 1 & 2)- and safe areas, general
purposes. For installation in areas exposed to
MUD and drilling/cleaning fluids. Meets the MUD
resistance requirement in NEK TS 606:2009.
IEC 60092-353
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour
Subject to change without prior notice
R
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound,
SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 01 RFOU 0,6/1KV P1/P8 3 x 35/16 mm2 IEC
60332-3-22
DRAKA 01 = Draka Norsk Kabel,
Black
Page 33 of 212
Core identification power cables
Single core – Black
Two cores - Blue – Brown
Three cores - Brown - Black – Grey
Four cores - Blue - Brown - Black – Grey
Five cores - Blue - Brown - Black - Grey – Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue – Brown
Three cores + earth (4G) - Yellow/green - Brown - Black – Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black – Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60445 Ed 5.0 2010-08
Range and dimensions
Number
of
elements
Cross
section
core,
mm²
Electrical
Cross
section
braid, mm²
Conductor
Diameter,
mm
Insulation
Thickness,
mm
Thickness
Inner
covering,
mm
Diameter
inner
covering,
mm
Diameter
Braid
Wire,
mm
Mechanical
cross-section
of the braid,
mm²
Weight of
Thickness Diameter
Cable
Outer
outer
Approx.
Sheath, mm sheath, mm
(Kg/Km)
Copper
content
Approx.
(kg/km)
1
1
1
1
1
1
1
1
1
1
1
16
25
35
50
70
95
120
150
185
240
300
2.5
4
6
6
10
10
10
10
10
16
16
5.15
6.45
7.65
9.0
10.85
12.60
14.20
15.90
17.70
20.15
22.60
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.1
1.1
1.1
1.1
1.1
1.1
1.2
1.2
1.2
1.2
1.2
9.5 ± 0.5
11.5 ± 0.8
12.5 ± 0.8
14.5 ± 0.8
16.5 ± 0.8
18.5 ± 0.8
20.5 ± 1
22.5 ± 1
24.5 ± 1
27.5 ± 1
30.5 ± 1.5
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
4.5
5.3
10.2
10.2
12.7
12.7
15.3
15.3
17.8
20.4
20.4
1.2
1.2
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
13 ± 0.8
14.5 ± 0.8
16 ± 0.8
18.5 ± 0.8
20.5 ± 1
23 ± 1
25 ± 1
27 ± 1
29.5 ± 1
32.5 ± 1.5
35.5 ± 1.5
360
490
650
840
1110
1400
1720
2060
2480
3130
3840
190
283
413
534
757
973
1231
1507
1838
2365
2959
2
3
4
5
7
12
19
27
37
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
4
4
6
6
6
10
10
10
16
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.1
1.1
1.1
1.2
1.2
1.2
9.5 ± 0.5
10 ± 0.8
11 ± 0.8
12 ± 0.8
12 ± 0.8
16 ± 0.8
19 ± 0.8
22.5 ± 1
25 ± 1
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
5.3
5.3
8.5
10.2
10.2
13.6
15.3
17.8
20.4
1.2
1.2
1.3
1.3
1.3
1.5
1.6
1.8
1.9
12.5 ± 0.8
13.5 ± 0.8
14.5 ± 0.8
15.5 ± 0.8
16 ± 0.8
20 ± 1
23 ± 1
27 ± 1
30 ± 1.5
270
295
380
440
480
720
990
1310
1670
80
94
139
170
198
301
415
550
716
3G
4G
5G
7G
1.5
1.5
1.5
1.5
-
1.6
1.6
1.6
1.6
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.1
10 ± 0.8
11 ± 0.8
12 ± 0.8
12 ± 0.8
0.2
0.3
0.3
0.3
5.3
8.5
10.2
10.2
1.2
1.3
1.3
1.3
13.5 ± 0.8
14.5 ± 0.8
15.5 ± 0.8
16 ± 0.8
295
380
440
480
94
139
170
197
2
2.5
4
2.0
1.0
1.1
10.5 ± 0.8
0.2
5.3
1.2
13.5 ± 0.8
320
98
3
4
5
7
12
19
27
37
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
6
6
6
6
10
10
16
16
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.1
1.2
1.2
1.2
1.4
11 ± 0.8
12 ± 0.8
13 ± 0.8
13.5 ± 0.8
18 ± 0.8
21 ± 1
25 ± 1
28.5 ± 1
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
8.5
10.2
10.2
11.9
15.3
17.8
20.4
22.9
1.3
1.3
1.4
1.4
1.6
1.7
1.9
2
14.5 ± 0.8
16 ± 0.8
17 ± 0.8
17.5 ± 0.8
22 ± 1
25.5 ± 1
30 ± 1.5
34 ± 1.5
390
460
530
610
930
1280
1720
2240
152
192
215
278
425
611
819
1074
3G
4G
5G
7G
2.5
2.5
2.5
2.5
-
2.0
2.0
2.0
2.0
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.1
11 ± 0.8
12 ± 0.8
13 ± 0.8
13.5 ± 0.8
0.3
0.3
0.3
0.3
8.5
10.2
10.2
11.9
1.3
1.3
1.4
1.4
14.5 ± 0.8
16 ± 0.8
17 ± 0.8
17.5 ± 0.8
390
460
530
610
152
192
215
277
2
3
4
5
4
4
4
4
6
6
6
6
2.55
2.55
2.55
2.55
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.1
11.5 ± 0.8
12 ± 0.8
13.5 ± 0.8
14.5 ± 0.8
0.3
0.3
0.3
0.3
8.5
10.2
10.2
11.9
1.3
1.3
1.4
1.4
15 ± 0.8
16 ± 0.8
17 ± 0.8
18.5 ± 0.8
410
480
560
660
157
210
247
300
3G
4G
5G
4
4
4
-
2.55
2.55
2.55
1.0
1.0
1.0
1.1
1.1
1.1
12 ± 0.8
13.5 ± 0.8
14.5 ± 0.8
0.3
0.3
0.3
10.2
10.2
11.9
1.3
1.4
1.4
16 ± 0.8
17 ± 0.8
18.5 ± 0.8
480
560
660
210
247
300
2
3
4
6
6
6
6
6
6
3.15
3.15
3.15
1.0
1.0
1.0
1.1
1.1
1.1
12.5 ± 0.8
13.5 ± 0.8
15 ± 0.8
0.3
0.3
0.3
10.2
10.2
11.9
1.3
1.4
1.4
16.5 ± 0.8
17.5 ± 0.8
18.5 ± 0.8
500
590
700
209
264
335
3G
4G
5G
6
6
6
-
3.15
3.15
3.15
1.0
1.0
1.0
1.1
1.1
1.1
13.5 ± 0.8
15 ± 0.8
16.5 ± 0.8
0.3
0.3
0.3
10.2
11.9
11.9
1.4
1.4
1.5
17.5 ± 0.8
18.5 ± 0.8
20.5 ± 1
590
700
820
264
335
390
Subject to change without prior notice
Page 34 of 212
Electrical
Cross
section
braid, mm²
10
10
10
Conductor
Diameter,
mm
Insulation
Thickness,
mm
2
3
4
Cross
section
core,
mm²
10
10
10
1.0
1.0
1.0
Thickness
Inner
covering,
mm
1.1
1.1
1.1
Diameter
inner
covering,
mm
14.5 ± 0.8
15.5 ± 0.8
17 ± 0.8
Diameter
Braid
Wire,
mm
0.3
0.3
0.3
Mechanical
cross-section
of the braid,
mm²
11.9
11.9
13.6
Weight of
Thickness Diameter
Cable
Outer
outer
Approx.
Sheath, mm sheath, mm
(Kg/Km)
1.4
18.5 ± 0.8 670
1.4
19.5 ± 0.8 780
1.5
21 ± 1
950
Copper
content
Approx.
(kg/km)
300
391
496
4.05
4.05
4.05
3G
4G
5G
10
10
10
-
4.05
4.05
4.05
1.0
1.0
1.0
1.1
1.1
1.2
15.5 ± 0.8
17 ± 0.8
19 ± 0.8
0.3
0.3
0.3
11.9
13.6
15.3
1.4
1.5
1.5
19.5 ± 0.8
21 ± 1
23 ± 1
780
950
1140
388
496
603
2
3
4
5
16
16
16
16
16
16
16
16
5.15
5.15
5.15
5.15
1.0
1.0
1.0
1.0
1.1
1.1
1.2
1.2
16.5 ± 0.8
17.5 ± 0.8
20 ± 1
22 ± 1
0.4
0.4
0.4
0.3
18.1
18.1
22.6
20.4
1.5
1.5
1.6
1.6
21 ± 1
22.5 ± 1
24.5 ± 1
26 ± 1
950
1120
1400
1590
481
626
806
930
3G
4G
5G
16
16
16
-
5.15
5.15
5.15
1.0
1.0
1.0
1.1
1.2
1.2
17.5 ± 0.8
20 ± 1
22 ± 1
0.3
0.3
0.3
13.6
15.3
15.3
1.5
1.6
1.6
22 ± 1
24 ± 1
26 ± 1
1060
1310
1540
571
734
881
2
3
4
25
25
25
16
16
16
6.45
6.45
6.45
1.2
1.2
1.2
1.2
1.2
1.2
20.5 ± 1
22 ± 1
24 ± 1
0.4
0.3
0.3
22.6
20.4
20.4
1.6
1.6
1.7
25.5 ± 1
26 ± 1
28.5 ± 1
1340
1560
1910
685
894
1125
3G
4G
5G
25
25
25
-
6.45
6.45
6.45
1.2
1.2
1.2
1.2
1.2
1.2
22 ± 1
24 ± 1
26.5 ± 1
0.3
0.3
0.3
15.3
17.8
20.4
1.6
1.7
1.8
26 ± 1
28.5 ± 1
31.5 ± 1.5
1510
1890
2260
844
1100
1356
2
3
4
35
35
35
16
16
16
7.65
7.65
7.65
1.2
1.2
1.2
1.2
1.2
1.2
23 ± 1
24.5 ± 1
27 ± 1
0.3
0.3
0.3
20.4
20.4
20.4
1.7
1.7
1.8
27.5 ± 1
29 ± 1
31.5 ± 1.5
1600
1930
2380
828
1142
1456
4G
5G
35
35
-
7.65
7.65
1.2
1.2
1.2
1.2
27 ± 1
30 ± 1.5
0.3
0.3
20.4
22.9
1.8
1.9
31.5 ± 1.5
35 ± 1.5
2380
2870
1456
1795
2
3
4
50
50
50
25
25
25
9.0
9.0
9.0
1.4
1.4
1.4
1.2
1.2
1.4
26.5 ± 1
28.5 ± 1
32 ± 1.5
0.4
0.4
0.4
31.7
31.7
31.7
1.8
1.9
2
31.5 ± 1.5
34 ± 1.5
37.5 ± 1.5
2190
2680
3320
1181
1617
2052
4G
5G
50
50
-
9.0
9.0
1.4
1.4
1.4
1.4
32 ± 1.5
35 ± 1.5
0.3
0.4
22.9
36.2
2
2.1
37 ± 1.5
41 ± 2
3230
4030
1966
2531
2
3
4
5
70
70
70
70
35
35
35
35
10.85
10.85
10.85
10.85
1.4
1.4
1.4
1.4
1.2
1.4
1.4
1.4
30.5 ± 1.5
33 ± 1.5
36.5 ± 1.5
40.5 ± 2
0.6
0.5
0.5
0.4
50.9
49.5
49.5
45.2
1.9
2
2.2
2.3
36.5 ± 1.5
39 ± 1.5
43 ± 2
46.5 ± 2
3040
3730
4600
5440
1782
2385
3018
3610
4G
5G
70
70
-
10.85
10.85
1.4
1.4
1.4
1.4
36.5 ± 1.5
40.5 ± 2
0.4
0.4
36.2
36.2
2.2
2.3
42.5 ± 2
46.5 ± 2
4470
5360
2888
3528
2
3
4
95
95
95
50
50
50
12.60
12.60
12.60
1.6
1.6
1.6
1.4
1.4
1.4
35 ± 1.5
37.5 ± 1.5
41.5 ± 2
0.6
0.5
0.5
61.1
56.5
63.6
2.1
2.2
2.4
41.5 ± 2
43.5 ± 2
48.5 ± 2
3960
4830
6020
2317
3126
4020
4G
95
-
12.60
1.6
1.4
41.5 ± 2
0.4
40.7
2.4
48 ± 2
5790
3796
2
3
4
120
120
120
60
60
60
14.20
14.20
14.20
1.6
1.6
1.6
1.4
1.4
1.6
38 ± 1.5
41 ± 2
46 ± 2
0.6
0.6
0.6
71.3
71.3
71.3
2.2
2.3
2.5
45 ± 2
48 ± 2
53.5 ± 2.5
4810
5950
7440
2891
3975
5100
4G
5G
120
120
-
14.20
14.20
1.6
1.6
1.6
1.6
46 ± 2
51 ± 2.5
0.4
0.5
45.2
49.5
2.5
2.7
52.5 ± 2.5
58.5 ± 2.5
7120
8610
4781
5909
4G
150
-
15.90
1.8
1.6
51 ± 2.5
0.5
49.5
2.7
58.5 ± 2.5
8790
5931
5G
150
-
15.90
1.8
1.8
57 ± 2.5
0.5
63.6
2.9
64.5 ± 3
10725
7445
4G
185
-
17.70
2.0
1.8
56.5 ± 2.5
0.5
56.5
2.9
64.5 ± 3
10700
7241
Number
of
elements
Ordering information
New Part
number
Old Part
number
800000
800001
800002
800003
800004
800005
Description
RFOU 0.6/1kV 1X 16/2.5 P1/P8
RFOU 0.6/1kV 1X 25/4mm² P1/P8
RFOU 0.6/1kV 1X 35/6mm² P1/P8
RFOU 0.6/1kV 1X 50/6mm² P1/P8
RFOU 0.6/1kV 1X 70/10mm² P1/P8
RFOU 0.6/1kV 1X 95/10mm² P1/P8
Subject to change without prior notice
Sheath
Colour
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
Stock
item
-
EAN No. DNK
EL No.
7021528000009
7021528000016
7021528000023
7021528000030
7021528000047
7021528000054
1044206
1044207
1044208
1044210
Page 35 of 212
New Part
number
20132989
20133004
Old Part
number
RFOU 0.6/1kV 1X 120/10 P1/P8
RFOU 0.6/1kV 1X 150/10 P1/P8
RFOU 0.6/1kV 1X 185/10 P1/P8
RFOU 0.6/1kV 1X 240/16 P1/P8
RFOU 0.6/1kV 1X 300/16 P1/P8
Sheath
Colour
BLACK
BLACK
BLACK
BLACK
BLACK
EAN No. DNK
EL No.
Yes
7021528000061
7021528000078
7021528000085
7021528000092
7021528000108
1044211
1044213
1044214
1044215
800024
800025
RFOU 0.6/1kV 2X 1.5/4mm² P1/P8
RFOU 0.6/1kV 3X 1.5/4mm² P1/P8
RFOU 0.6/1kV 4X 1.5/6mm² P1/P8
RFOU 0.6/1kV 5X 1.5/6mm² P1/P8
RFOU 0.6/1kV 7X 1.5/6mm² P1/P8
RFOU 0.6/1kV 12X 1.5/10 P1/P8
RFOU 0.6/1kV 19X 1.5/10 P1/P8
RFOU 0.6/1kV 27X 1.5/10 P1/P8
RFOU 0.6/1kV 37X 1.5/16 P1/P8
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
Yes
Yes
Yes
Yes
Yes
-
7021528000153
7021528000184
7021528000191
7021528000207
7021528000214
7021528000221
7021528000238
7021528000245
7021528000252
1044220
1044240
1044260
1044305
1044307
1044312
1044319
1044327
1044337
800017
800026
800028
RFOU 0.6/1kV 3G 1.5mm² P1/P8
RFOU 0.6/1kV 4G 1.5mm² P1/P8
RFOU 0.6/1kV 5G 1.5mm² P1/P8
RFOU 0.6/1kV 7G 1.5mm² P1/P8
BLACK
BLACK
BLACK
BLACK
-
7021528000160
7021528000177
7021528000269
7021528000283
-
RFOU 0.6/1kV 2X 2.5/4mm² P1/P8
RFOU 0.6/1kV 3X 2.5/6mm² P1/P8
RFOU 0.6/1kV 4X 2.5/6mm² P1/P8
RFOU 0.6/1kV 5X 2.5/6mm² P1/P8
RFOU 0.6/1kV 7X 2.5/6mm² P1/P8
RFOU 0.6/1kV 12X 2.5/10 P1/P8
RFOU 0.6/1kV 19X 2.5/10 P1/P8
RFOU 0.6/1kV 27X 2.5/16 P1/P8
RFOU 0.6/1kV 37X 2.5/16 P1/P8
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
Yes
Yes
Yes
-
7021528000290
7021528000320
7021528000351
7021528000368
7021528000375
7021528000382
7021528000399
7021528000405
7021528000412
1044221
1044241
1044261
1044355
1044357
1044362
1044369
1044377
1044387
800044
RFOU 0.6/1kV 3G 2.5mm² P1/P8
RFOU 0.6/1kV 4G 2.5mm² P1/P8
RFOU 0.6/1kV 5G 2.5mm² P1/P8
RFOU 0.6/1kV 7G 2.5mm² P1/P8
BLACK
BLACK
BLACK
BLACK
Yes
-
7021528000306
7021528000337
7021528000344
7021528000443
-
800048
RFOU 0.6/1kV 2X 4/6mm² P1/P8
RFOU 0.6/1kV 3X 4/6mm² P1/P8
RFOU 0.6/1kV 4X 4/6mm² P1/P8
RFOU 0.6/1kV 5X 4/6mm² P1/P8
BLACK
BLACK
BLACK
BLACK
Yes
Yes
-
7021528000450
7021528000467
7021528000474
7021528000481
1044222
1044242
1044262
-
800043
800050
RFOU 0.6/1kV 3G 4mm² P1/P8
RFOU 0.6/1kV 4G 4mm² P1/P8
RFOU 0.6/1kV 5G 4mm² P1/P8
BLACK
BLACK
BLACK
Yes
-
7021528000498 7021528000436 7021528000504 -
RFOU 0.6/1kV 2X 6/6mm² P1/P8
RFOU 0.6/1kV 3X 6/6mm² P1/P8
RFOU 0.6/1kV 4X 6/6mm² P1/P8
BLACK
BLACK
BLACK
Yes
Yes
-
7021528000511 1044223
7021528000528 1044243
7021528000535 1044263
RFOU 0.6/1kV 3G 6mm² P1/P8
RFOU 0.6/1kV 4G 6mm² P1/P8
RFOU 0.6/1kV 5G 6mm² P1/P8
BLACK
BLACK
BLACK
-
7021528000559 7021528000542 7021528000566 -
RFOU 0.6/1kV 2X 10/10mm² P1/P8
RFOU 0.6/1kV 3X 10/10mm² P1/P8
RFOU 0.6/1kV 4X 10/10mm² P1/P8
BLACK
BLACK
BLACK
Yes
-
7021528000573 1044224
7021528000580 1044244
7021528000597 1044264
800060
800062
800061
RFOU 0.6/1kV 3G 10mm² P1/P8
RFOU 0.6/1kV 4G 10mm² P1/P8
RFOU 0.6/1kV 5G 10mm² P1/P8
BLACK
BLACK
BLACK
-
7021528000603 7021528000627 7021528000610 -
800116
RFOU 0.6/1kV 2X 16/16mm² P1/P8
RFOU 0.6/1kV 3X 16/16mm² P1/P8
RFOU 0.6/1kV 4X 16/16mm² P1/P8
RFOU 0.6/1kV 5X 16/16mm² P1/P8
BLACK
BLACK
BLACK
BLACK
Yes
Yes
-
7021528000634
7021528000641
7021528000658
7021528001167
800068
800066
800067
RFOU 0.6/1kV 3G 16mm² P1/P8
RFOU 0.6/1kV 4G 16mm² P1/P8
RFOU 0.6/1kV 5G 16mm² P1/P8
BLACK
BLACK
BLACK
-
7021528000689 7021528000665 7021528000672 -
800069
RFOU 0.6/1kV 2X 25/16mm² P1/P8
RFOU 0.6/1kV 3X 25/16mm² P1/P8
BLACK
BLACK
Yes
7021528000696 1044226
7021528000702 1044246
800008
20110465
20110466
20110467
20110469
20110470
20111209
20110471
20104950
20110472
20110468
20110473
20110475
20110476
800036
800037
20109423
20120716
800040
20114663
20110474
800033
20114348
20110477
20110478
20110479
20110480
20110481
20110482
20110483
800055
20117131
800056
20110484
20110485
20110486
20110487
20110488
20110489
20110490
Description
Subject to change without prior notice
Stock
item
1044225
1044245
1044265
-
Page 36 of 212
New Part
number
20110491
Old Part
number
RFOU 0.6/1kV 4X 25/16mm² P1/P8
Sheath
Colour
BLACK
Stock
item
Yes
7021528000719 1044266
800073
800072
800074
RFOU 0.6/1kV 3G 25mm² P1/P8
RFOU 0.6/1kV 4G 25mm² P1/P8
RFOU 0.6/1kV 5G 25mm² P1/P8
BLACK
BLACK
BLACK
-
7021528000733 7021528000726 7021528000740 -
800075
RFOU 0.6/1kV 2X 35/16mm² P1/P8
RFOU 0.6/1kV 3X 35/16mm² P1/P8
RFOU 0.6/1kV 4X 35/16mm² P1/P8
BLACK
BLACK
BLACK
Yes
-
7021528000757 7021528000764 1044247
7021528000771 1044267
800078
800079
RFOU 0.6/1kV 4G 35mm² P1/P8
RFOU 0.6/1kV 5G 35mm² P1/P8
BLACK
BLACK
-
7021528000788 7021528000795 -
800081
RFOU 0.6/1kV 2X 50/25mm² P1/P8
RFOU 0.6/1kV 3X 50/25mm² P1/P8
RFOU 0.6/1kV 4X 50/25mm² P1/P8
BLACK
BLACK
BLACK
Yes
-
7021528000818 7021528000825 1044248
7021528000832 1044268
800084
800085
RFOU 0.6/1kV 4G 50mm² P1/P8
RFOU 0.6/1kV 5G 50mm² P1/P8
BLACK
BLACK
-
7021528000849 7021528000856 -
800087
800089
800092
RFOU 0.6/1kV 2X 70/35mm² P1/P8
RFOU 0.6/1kV 3X 70/35mm² P1/P8
RFOU 0.6/1kV 4X 70/35mm² P1/P8
RFOU 0.6/1kV 5X 70/35mm² P1/P8
BLACK
BLACK
BLACK
BLACK
Yes
-
7021528000870
7021528000887
7021528000894
7021528000924
800090
800091
RFOU 0.6/1kV 4G 70mm² P1/P8
RFOU 0.6/1kV 5G 70mm² P1/P8
BLACK
BLACK
-
7021528000900 7021528000917 -
800094
RFOU 0.6/1kV 2X 95/50mm² P1/P8
RFOU 0.6/1kV 3X 95/50mm² P1/P8
RFOU 0.6/1kV 4X 95/50mm² P1/P8
BLACK
BLACK
BLACK
Yes
Yes
7021528000948 7021528000955 1044250
7021528000962 1044270
800097
RFOU 0.6/1kV 4G 95mm² P1/P8
BLACK
-
7021528000979 -
800105
RFOU 0.6/1kV 2X 120/60 P1/P8
RFOU 0.6/1kV 3X 120/60 P1/P8
RFOU 0.6/1kV 4X 120/60 P1/P8
BLACK
BLACK
BLACK
Yes
-
7021528001006 7021528001013 1044251
7021528001051 -
800106
800099
RFOU 0.6/1kV 4G 120mm² P1/P8
RFOU 0.6/1kV 5G 120mm² P1/P8
BLACK
BLACK
-
7021528001068 7021528000993 -
RFOU 0.6/1kV 4G 150mm² P1/P8
RFOU 0.6/1kV 5G 150mm² P1/P8
BLACK
BLACK
-
7021528001082 7021528001150 -
RFOU 0.6/1kV 4G 185mm² P1/P8
BLACK
-
7021528001105 -
20110492
20110493
20110494
20110495
20109424
20109426
20109427
20109428
20109429
20114321
20132887
800110
Description
EAN No. DNK
EL No.
1044249
1044269
-
Electrical values power cables
Number of
elements
Cross
section
core,
mm²
Electrical
Cross
section
braid, mm²
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table
second,
B.4, Ampere
Ampere
1
1
1
1
1
1
1
1
1
1
1
16
25
35
50
70
95
120
150
185
240
300
2.5
4
6
6
10
10
10
10
10
16
16
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
1.16
0.734
0.529
0.391
0.27
0.195
0.154
0.126
0.1
0.0762
0.0607
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
0.116
0.110
0.106
0.104
0.099
0.097
0.094
0.092
0.091
0.089
0.087
0.140
0.132
0.128
0.125
0.119
0.116
0.113
0.111
0.109
0.107
0.105
96
127
157
196
242
293
339
389
444
522
601
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
2
3
4
5
1.5
1.5
1.5
1.5
4
4
6
6
STCC
STCC
STCC
STCC
12.2
12.2
12.2
12.2
15.6
15.6
15.6
15.6
0.110
0.110
0.110
0.110
0.132
0.132
0.132
0.132
20
16
16
13.5
210
210
210
210
Subject to change without prior notice
Page 37 of 212
Number of
elements
7
12
19
27
37
Cross
section
core,
mm²
1.5
1.5
1.5
1.5
1.5
3G
4G
5G
7G
Electrical
Cross
section
braid, mm²
6
10
10
10
16
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 6009220°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table
B.4, Ampere
STCC
12.2
15.6
0.110
0.132
12
STCC
12.2
15.6
0.110
0.132
10
STCC
12.2
15.6
0.110
0.132
8.5
STCC
12.2
15.6
0.110
0.132
7.5
STCC
12.2
15.6
0.110
0.132
7
Short circuit
rating 1
second,
Ampere
210
210
210
210
210
1.5
1.5
1.5
1.5
-
STCC
STCC
STCC
STCC
12.2
12.2
12.2
12.2
15.6
15.6
15.6
15.6
0.110
0.110
0.110
0.110
0.132
0.132
0.132
0.132
20
16
16
12.5
210
210
210
210
2
3
4
5
7
12
19
27
37
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
6
6
6
6
10
10
16
16
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.123
0.123
0.123
0.123
0.123
0.123
0.123
0.123
0.123
26
21
21
17.5
15.5
13
11
10
9
350
350
350
350
350
350
350
350
350
3G
4G
5G
7G
2.5
2.5
2.5
2.5
-
STCC
STCC
STCC
STCC
7.56
7.56
7.56
7.56
9.64
9.64
9.64
9.64
0.103
0.103
0.103
0.103
0.123
0.123
0.123
0.123
26
21
21
16.5
350
350
350
350
2
3
4
5
4
4
4
4
6
6
6
6
STCC
STCC
STCC
STCC
4.7
4.7
4.7
4.7
5.99
5.99
5.99
5.99
0.096
0.096
0.096
0.096
0.115
0.115
0.115
0.115
34
28
28
23.5
560
560
560
560
3G
4G
5G
4
4
4
-
STCC
STCC
STCC
4.7
4.7
4.7
5.99
5.99
5.99
0.096
0.096
0.096
0.115
0.115
0.115
34
28
28
560
560
560
2
3
4
6
6
6
6
6
6
STCC
STCC
STCC
3.11
3.11
3.11
3.97
3.97
3.97
0.090
0.090
0.090
0.108
0.108
0.108
44
36
36
840
840
840
3G
4G
5G
6
6
6
-
STCC
STCC
STCC
3.11
3.11
3.11
3.97
3.97
3.97
0.090
0.090
0.090
0.108
0.108
0.108
44
36
36
840
840
840
2
3
4
10
10
10
10
10
10
STCC
STCC
STCC
1.84
1.84
1.84
2.35
2.35
2.35
0.084
0.084
0.084
0.101
0.101
0.101
61
50
50
1400
1400
1400
3G
4G
5G
10
10
10
-
STCC
STCC
STCC
1.84
1.84
1.84
2.35
2.35
2.35
0.084
0.084
0.084
0.101
0.101
0.101
61
50
50
1400
1400
1400
2
3
4
5
16
16
16
16
16
16
16
16
STCC
STCC
STCC
STCC
1.16
1.16
1.16
1.16
1.48
1.48
1.48
1.48
0.080
0.080
0.080
0.080
0.096
0.096
0.096
0.096
80
67
67
56
2240
2240
2240
2240
3G
4G
5G
16
16
16
-
STCC
STCC
STCC
1.16
1.16
1.16
1.48
1.48
1.48
0.080
0.080
0.080
0.096
0.096
0.096
80
67
67
2240
2240
2240
2
3
4
25
25
25
16
16
16
STCC
STCC
STCC
0.734
0.734
0.734
0.936
0.936
0.936
0.079
0.079
0.079
0.095
0.095
0.095
108
89
89
3500
3500
3500
3G
4G
5G
25
25
25
-
STCC
STCC
STCC
0.734
0.734
0.734
0.936
0.936
0.936
0.079
0.079
0.079
0.095
0.095
0.095
108
89
89
3500
3500
3500
2
35
16
STCC
0.529
0.675
0.076
0.092
133
4900
Subject to change without prior notice
Page 38 of 212
Number of
elements
3
4
Cross
section
core,
mm²
35
35
Electrical
Conductor
Cross
type 2
section
braid, mm²
16
STCC
16
STCC
Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table
second,
B.4, Ampere
Ampere
0.529
0.675
0.076
0.092
110
4900
0.529
0.675
0.076
0.092
110
4900
4G
5G
35
35
-
STCC
STCC
0.529
0.529
0.675
0.675
0.076
0.076
0.092
0.092
110
110
4900
4900
2
3
4
50
50
50
25
25
25
STCC
STCC
STCC
0.391
0.391
0.391
0.499
0.499
0.499
0.076
0.076
0.076
0.092
0.092
0.092
167
137
137
7000
7000
7000
4G
5G
50
50
-
STCC
STCC
0.391
0.391
0.499
0.499
0.076
0.076
0.092
0.092
137
137
7000
7000
2
3
4
5
70
70
70
70
35
35
35
35
STCC
STCC
STCC
STCC
0.27
0.27
0.27
0.27
0.344
0.344
0.344
0.344
0.074
0.074
0.074
0.074
0.088
0.088
0.088
0.088
206
169
169
141.5
9800
9800
9800
9800
4G
5G
70
70
-
STCC
STCC
0.27
0.27
0.344
0.344
0.074
0.074
0.088
0.088
169
169
9800
9800
2
3
4
95
95
95
50
50
50
STCC
STCC
STCC
0.195
0.195
0.195
0.249
0.249
0.249
0.073
0.073
0.073
0.088
0.088
0.088
249
205
205
13300
13300
13300
4G
95
-
STCC
0.195
0.249
0.073
0.088
205
13300
2
3
4
120
120
120
60
60
60
STCC
STCC
STCC
0.154
0.154
0.154
0.196
0.196
0.196
0.072
0.072
0.072
0.086
0.086
0.086
288
237
237
16800
16800
16800
4G
5G
120
120
-
STCC
STCC
0.154
0.154
0.196
0.196
0.072
0.072
0.086
0.086
237
237
16800
16800
4G
5G
150
150
-
STCC
STCC
0.126
0.126
0.161
0.161
0.072
0.072
0.087
0.087
272
272
21000
21000
4G
185
-
STCC
0.1
0.128
0.072
0.086
311
25900
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 39 of 212
Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8, large single core
cables
Flame retardant halogen-free power
cable. Mud resistant. Single core
cable.
RFOU 0,6/1(1,2)kV
EPR/EPR/TCWB/EVA
NEK TS 606 CodeP1/P8
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
Fixed installation for power,control and lighting in both EX
(Zone 0, 1 & 2)- and safe areas, general purposes. For
installation in areas exposed to MUD and drilling/cleaning
fluids. Meets the MUD resistance requirement in NEK TS
606:2009.
IEC 60092-353
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour
Subject to change without prior notice
R
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound,
SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 01 RFOU 0,6/1KV P1/P8 1 x 500/25 mm2 IEC
60332-3-22
DRAKA 01 = Draka Norsk Kabel,
Black
Page 40 of 212
Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60445 ED 5.0 2010-08
Range and dimensions
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
1
400
25
26.00
2.6
1.4
1
1
500
630
25
25
29.0
32.80
2.8
2.8
1.4
1.4
Diameter
inner
covering,
mm
34.5 ±
1.5
38 ± 1.5
41.5 ± 2
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
0.4
31.7
2.1
40.5 ± 2
5070
3970
0.4
0.4
36.2
40.7
2.2
2.3
44 ± 2
48 ± 2
6220
7650
4923
6195
Ordering information
New Part
number
Old Part
number
20110761
800012
800013
Description
Sheath Colour Stock item
RFOU 0.6/1kV 1X 400/25 P1/P8
RFOU 0.6/1kV 1X 500/25 P1/P8
RFOU 0.6/1kV 1X 630/25 P1/P8
BLACK
BLACK
BLACK
-
EAN No. DNK
EL No.
7021528000115 7021528000122 7021528000139 -
Electrical values power cables
Number of
elements
Cross
section
core,
mm²
Electrical
Cross
section
braid, mm²
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table
second,
B.4, Ampere
Ampere
1
400
25
STCC
0.0475
0.0606
0.087
0.104
1
500
25
STCC
0.0369
0.0471
0.085
0.103
1
630
25
STCC
0.0286
0.0365
0.083
0.100
690 dc / 670
ac
780 dc / 720
ac
890 dc / 780
ac
56000
70000
88200
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 41 of 212
Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8, double braided
Flame retardant halogen-free power
cable. Mud resistant. Double braided.
RFOU 0,6/1(1,2)kV
EPR/EPR/TCWB/EVA
NEK TS 606 CodeP1/P8
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
IEC 60092-353
Fixed installation for power,control and lighting in both EX IEC 60228 class 2
IEC 60092-360
(Zone 0, 1 & 2)- and safe areas, general purposes. For
installation in areas exposed to MUD and drilling/cleaning IEC 60092-360
fluids. Meets the MUD resistance requirement in NEK TS IEC 60332-1-2
IEC 60332-3-22
606:2009.
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour
Subject to change without prior notice
R
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoset compound
PET tape + rubberized Polyamide tape
O
Two layers of tinned copper wire braid (double braid)
PET tape + rubberized Polyamide tape
U
Flame retardant, halogen-free and mud resistant thermoset compound,
SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 01 RFOU 0,6/1kV P1/P8 3 x 185/95 mm2 IEC
60332-3-22
DRAKA 01 = Draka Norsk Kabel,
Black
Page 42 of 212
Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60445 ED 5.0 2010-08
Range and dimensions
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
3
4
150
150
75
75
15.9
15.9
1.8
1.8
1.6
2
46 ± 2
0.4
51.5 ± 2.5 0.5
90.5
99
2.6
2.8
54 ± 2.5
61 ± 3
7470
9480
4981
6444
3
4
185
185
95
95
17.70
17.7
2.0
2.0
1.6
2
50.5 ± 2.5 0.5
57 ± 2.5 0.5
127.2
113.1
2.7
3
59.5 ± 2.5 9230
67 ± 3
11430
6283
7837
3
240
120
20.15
2.2
1.8
57.5 ± 2.5 0.6
142.5
3
68 ± 3
8046
EAN No. DNK
EL No.
11800
Ordering information
New Part
number
Old Part
number
Description
20109430
Sheath Colour Stock item
800109
RFOU 0.6/1kV 3X 150/75 P1/P8
RFOU 0.6/1kV 4X 150/75 P1/P8
BLACK
BLACK
-
7021528001020 1044252
7021528001099 -
800111
RFOU 0.6/1kV 3X 185/95 P1/P8
RFOU 0.6/1kV 4X 185/95 P1/P8
BLACK
BLACK
-
7021528000931 7021528001112 -
RFOU 0.6/1kV 3X 240/120 P1/P8
BLACK
-
7021528001129 -
20109425
20109431
Electrical values power cables
Number of
elements
Cross
section
core,
mm²
Electrical
Cross
section
braid, mm²
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table
second,
B.4, Ampere
Ampere
3
4
150
150
75
75
STCC
STCC
0.126
0.126
0.161
0.161
0.072
0.072
0.087
0.087
272
272
21000
21000
3
4
185
185
95
95
STCC
STCC
0.1
0.1
0.128
0.128
0.072
0.072
0.086
0.086
311
311
25900
25900
3
240
120
STCC
0.0762
0.0972
0.072
0.086
365
33600
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 43 of 212
Halogen-free, mud resistant MV power cable, RFOU 3,6/6(7,2)kV, P2/P9
Flame retardant halogen-free medium
voltage (MV) cable. Mud resistant
RFOU 3,6/6(7,2) kV
EPR/EPR/TCWB/EVA
NEK 606 CodeP2/P9
Operating temperature
Operating Voltage
: 90°C
: 3,6/6(7,2) kV
Standards applied
Application
Fixed installation for medium voltage (MV) power in both
EX- and safe areas, general purposes. For installation in
areas exposed to MUD and drilling/cleaning fluids.
IEC 60092-354
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Conductor screen
semiconductive
Insulation
Insulation screen
semicoductive
Tinned stranded and compressed copper (STCC), IEC 60228 class 2
Semiconductive layer (EP-rubber)
R
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour
Subject to change without prior notice
F
EP-rubber, IEC 60092-360 (EPR)
Semiconductive layer (EP-rubber)
Cores are laid up together. Cores are identified by Brown, Black or Grey
threads under and over the metallic screen on each conductor.
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound,
SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 04 RFOU 3,6/6(7,2)KV P2/P9 3 x 120/60
mm2 IEC 60332-3-22
DRAKA 04 = Draka Industrial Cable, Germany
Red
Page 44 of 212
Range and dimensions
Cross
Number
section
of
core,
elements
mm²
1
16
1
25
1
35
1
50
1
70
1
95
1
120
1
150
1
185
1
240
1
300
Cross
section
screen,
mm²
11
11
13
13
16
16
20
22
25
25
30
Conductor
Diameter,
mm
Insulation
Thickness,
mm
5,2
6,5
7,4
8,8
10,3
12,1
13,6
15,1
16,8
19,1
21,5
3
3
3
3
3
3
3
3
3
3
3
35
35
35
35
45
50
60
75
95
95
95
5,2
6,5
7,4
8,8
10,3
12,1
13,6
15,1
16,8
19,1
21,5
16
25
35
50
70
95
120
150
185
240
300
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,6
2,8
Thickness
Inner
covering,
mm
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,2
1,2
1,2
1,2
Diameter
inner
covering,
mm
16,5±1,0
18,0±1,0
19,0±1,0
20,5±1,0
22,0±1,0
24,0±1,5
25,0±1,5
27,0±1,5
28,5±1,5
31,5±1,5
34,0±1,5
Thickness
Diameter
Outer
Braid
Sheath,
Wire, mm
mm
0,3
1,6
0,3
1,6
0,3
1,6
0,3
1,7
0,3
1,8
0,3
1,9
0,4
1,9
0,4
2,0
0,4
2,0
0,4
2,1
0,4
2,2
Diameter
outer
sheath,
mm
22,0±1,5
23,0±1,5
24,0±1,5
25,5±1,5
27,5±1,5
29,5±1,5
31,5±2,0
33,5±2,0
35,0±2,0
37,5±2,0
41,0±2,5
Weight of
Cable
Approx.
(Kg/Km)
850
970
1150
1300
1600
2000
2300
2710
3230
3930
4700
Copper
content
Approx.
(kg/km)
452
554
675
830
1060
1323
1677
2041
2433
2993
3626
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,6
2,8
1,2
1,2
1,2
1,4
1,4
1,4
1,6
1,6
1,6
1,8
1,8
34,5±1,5
37,5±1,5
39,5±1,5
43,0±2,0
46,0±2,0
50,0±2,0
53.5±2.0
56,5±2,0
60,5±2,5
66,5±2,5
70,0±3,0
0,4
0,4
0,4
0,4
0,5
0,5
0.5
0,5
0,6
0,6
0,6
42,0±2,5
45,0±2,5
47,0±2,5
50,5±3,0
54,5±3,0
58,5±3,0
62.5±3.5
66,5±3,5
70,0±3,5
77,0±4,0
80,5±4,5
3100
3570
4020
4700
5900
7200
8200
9600
11250
14000
16500
1419
1706
1972
2462
3047
4108
4988
6173
7364
9033
10794
2,3
2,4
2,5
2,6
2,7
2,8
3,0
3,1
3,2
3,5
3,6
Ordering information
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
804200
804201
804202
804203
804204
804205
804206
804207
804208
804209
804210
RFOU 3.6/6KV 1X 16/11mm² P2/P9
RFOU 3.6/6KV 1X 25/11mm² P2/P9
RFOU 3.6/6KV 1X 35/13mm² P2/P9
RFOU 3.6/6KV 1X 50/13mm² P2/P9
RFOU 3.6/6KV 1X 70/16mm² P2/P9
RFOU 3.6/6KV 1X 95/16mm² P2/P9
RFOU 3.6/6KV 1X 120/20mm² P2/P9
RFOU 3.6/6KV 1X 150/22mm² P2/P9
RFOU 3.6/6KV 1X 185/25mm² P2/P9
RFOU 3.6/6KV 1X 240/25mm² P2/P9
RFOU 3.6/6KV 1X 300/30mm² P2/P9
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
-
7021528042009
7021528042016
7021528042023
7021528042030
7021528042047
7021528042054
7021528042061
7021528042078
7021528042085
7021528042092
7021528042108
-
804220
804221
804222
804223
804224
804225
804226
804227
804228
804229
804230
RFOU 3.6/6KV 3X 16/35mm² P2/P9
RFOU 3.6/6KV 3X 25/35mm² P2/P9
RFOU 3.6/6KV 3X 35/35mm² P2/P9
RFOU 3.6/6KV 3X 50/35mm² P2/P9
RFOU 3.6/6KV 3X 70/45mm² P2/P9
RFOU 3.6/6KV 3X 95/50mm² P2/P9
RFOU 3.6/6KV 3X 120/60mm² P2/P9
RFOU 3.6/6KV 3X 150/75mm² P2/P9
RFOU 3.6/6KV 3X 185/95mm² P2/P9
RFOU 3.6/6KV 3X 240/95mm² P2/P9
RFOU 3.6/6KV 3X 300/95mm² P2/P9
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
-
7021528042207
7021528042214
7021528042221
7021528042238
7021528042245
7021528042252
7021528042269
7021528042276
7021528042283
7021528042290
7021528042306
-
Subject to change without prior notice
Page 45 of 212
Electrical values power cables
Number
of
elements
Cross
section
core,
mm²
Cross
section
screen,
mm²
Conductor
type 2
Max.
Max.
conductor
conductor
resistance at resistance at
20°C,
90°C,
Ohm/km
Ohm/km
Reactance
at 50Hz,
Ohm/km
Reactance
at 60Hz,
Ohm/km
Capacitans
per phase,
nF/km
Current
rating IEC
60092-352
Table B.4,
Ampere
Short
circuit
rating 1
second,
Ampere
1
1
1
1
1
1
1
1
1
1
1
16
25
35
50
70
95
120
150
185
240
300
11
11
13
13
16
16
20
22
25
25
30
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100
0,0762
0,0607
1,48
0,936
0,675
0,499
0,344
0,249
0,196
0,161
0,128
0,0972
0,0774
0,149
0,139
0,133
0,126
0,121
0,115
0,119
0,109
0,105
0,102
0,099
0,179
0,167
0,160
0,152
0,145
0,138
0,143
0,131
0,127
0,122
0,119
310
360
390
440
490
560
610
660
730
780
810
96
127
157
196
242
293
339
389
444
522
601
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
3
3
3
3
3
3
3
3
3
3
3
16
25
35
50
70
95
120
150
185
240
300
35
35
35
35
45
50
60
75
95
95
95
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100
0,0762
0,0607
1,48
0,936
0,675
0,499
0,344
0,249
0,196
0,161
0,128
0,0972
0,0774
0,121
0,112
0,108
0,102
0,097
0,093
0.090
0,088
0,085
0,083
0,082
0,145
0,135
0,129
0,123
0,117
0,112
0,108
0,105
0,102
0,100
0,098
310
360
390
440
490
560
610
660
730
780
810
67
89
110
137
169
205
237
272
311
365
421
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
Installation recommendations
Minimum Bending Radius during
Installation
15 x D
Minimum Bending Radius
Fixed Installed
9xD
Subject to change without prior notice
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 46 of 212
80
0.47
Halogen-free, mud resistant MV power cable, RFOU 6/10(12)kV, P3/P10
Flame retardant halogen-free medium
voltage (MV) cable. Mud resistant
RFOU 6/10(12) kV
EPR/EPR/TCWB/EVA
NEK TS 606 CodeP3/P10
Operating temperature
Operating Voltage
: 90°C
: 6/10(12) kV
Standards applied
Application
IEC 60092-354
IEC 60228 class 2
Fixed installation for medium voltage (MV) power in both EX- IEC 60092-360
and safe areas, general purposes. For installation in areas
IEC 60092-360
exposed to MUD and drilling/cleaning fluids. Meets the MUD IEC 60332-1-2
resistance requirement in NEK TS 606:2009
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Conductor screen
semiconductive
Insulation
Insulation screen
semicoductive
Tinned stranded and compressed copper (STCC), IEC 60228 class 2
Semiconductive layer (EP-rubber)
R
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour
Subject to change without prior notice
F
EP-rubber, IEC 60092-360 (EPR)
Semiconductive layer (EP-rubber)
Cores are laid up together. Cores are identified by Brown, Black or Grey
threads under and over the metallic screen on each conductor.
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound,
SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 04 RFOU 6/10(12)KV P3/P10 3 x 95/50 mm2
IEC 60332-3-22
DRAKA 04 = Draka Industrial Cable, Germany
Red
Page 47 of 212
Range and dimensions
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
Diameter
inner
covering,
mm
1
16
11
5.2
3.4
1.0
18.5 ±1.0 0.3
12.7
1.6
1
25
11
6.5
3.4
1.0
20,0 ±1.0 0.3
12.7
1.7
1
35
11
7.4
3.4
1.0
0.3
12.7
1.7
1
50
11
8.8
3.4
1.0
0.3
12.7
1.9
1
70
16
10.3
3.4
1.0
23.5 ±1.5 0.3
17.8
1.9
1
95
16
12.1
3.4
1.2
25.5 ±1.5 0.3
20.4
2.0
1
120
20
13.6
3.4
1.2
27.5 ±
1.5
0.3
22.9
2.0
1
150
19
15.1
3.4
1.2
28.5 ±1.5 0.3
20.4
2.0
1
185
18
16.8
3.4
1.2
30.5 ±1.5 0.3
20.4
2.1
1
240
21
19.1
3.4
1.2
33.0 ±
1.5
0.3
22.9
2.1
1
300
29
21.5
3.4
1.2
35 ±1.5
0.3
30.5
2.2
1
400
35
24.5
3.4
1.2
36 ±1.5
0.4
40.7
2.3
1
500
40
27.5
3.4
1.4
0.4
49.8
2.5
1
630
40
32.3
3.4
1.4
0.4
49.8
2.7
3
16
32
5.2
3.4
1.4
0.4
36.2
2.4
3
25
31
6.5
3.4
1.4
0.4
31
2.4
3
35
35
7.4
3.4
1.4
0.4
35
3
50
31
8.8
3.4
1.6
0.4
3
70
35
10.3
3.4
1.6
3
95
50
12.1
3.4
1.6
3
120
60
13.6
3.4
1.6
3
150
75
15.1
3.4
1.6
3
185
45
16.8
3.4
1.6
3
240
53
19.1
3.4
1.6
3
300
55
21.5
3.4
1.6
21.0 ±
1.5
22.0 ±
1.0
41.5 ±
2.0
46.5 ±
2.0
39.0 ±
1.5
42.0 ±
1.5
43.5 ±
2.0
47.0 ±
2.0
50.0 ±
2.0
54.0 ±
2.0
57.5 ±
2.0
60 ± 2
64.5 ±
2.5
69.5 ±
2.5
74.5 ±
3.0
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
900
420
1100
516
26.0± 1.5 1200
611
24.0 ±
1,5
25.0 ±
1,5
28.0 ±
1.5
30.0 ±
2.0
32.0 ±
2.0
34.0 ±
2.0
35.0 ±
2.0
36.5 ±
2.0
1450
780
1700
971
2100
1251
2350
1506
2600
1793
3100
2138
39.0± 2.0 3800
2702
41.5 ±
2.5
45.5 ±
2.5
49.5 ±
2.5
54.5 ±
3.0
4600
3395
5900
4536
7350
5782
8750
7016
3300
1145
3800
1465
2.5
51.5± 3.0 4300
1573
31
2.8
55 ± 3
5000
2124
0.4
40.7
2.8
58.5 ± 3
6000
2880
0.4
54.3
2.8
62.5± 3.0 7500
3975
0.5
70.7
3
0.6
86.5
3.2
0.5
56.5
3.3
0.5
63.6
0.5
70.7
46.0 ±
2.5
49.5 ±
2.5
66.5 ±
3.0
70.5 ± 3
74.0 ±
3.5
8350
4650
9800
5634
11300
6511
3.5
79.5± 3.5 13300
8609
3.7
85.0± 4.0 16300
10725
Ordering information
New Part
number
Old Part
number
804000
804001
804002
20080191
20113313
804005
20076157
804007
20098204
20077819
20076156
804011
804012
Description
RFOU 6/10KV 1X 16/11mm² P3/P10
RFOU 6/10KV 1X 25/11mm² P3/P10
RFOU 6/10KV 1X 35/11mm² P3/P10
RFOU 6/10KV 1X 50/11mm² P3/P10
RFOU 6/10KV 1X 70/16mm² P3/P10
RFOU 6/10KV 1X 95/16mm² P3/P10
RFOU 6/10KV 1X 120/20mm² P3/P10
RFOU 6/10KV 1X 150/19mm² P3/P10
RFOU 6/10KV 1X185/18mm² P3/P10
RFOU 6/10KV 1X 240/21mm² P3/P10
RFOU 6/10KV 1X 300/29mm² P3/P10
RFOU 6/10KV 1X 400/35mm² P3/P10
RFOU 6/10KV 1X 500/40mm² P3/P10
Subject to change without prior notice
Sheath Colour
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
Stock item
Yes
Yes
Yes
-
EAN No. DNK
7021528040005
7021528040012
7021528040029
7021528040036
7021528040043
7021528040050
7021528040067
7021528040074
7021528040081
7021528040098
7021528040104
7021528040111
7021528040128
Page 48 of 212
EL No.
1061020
1061021
1061000
1061001
1061002
1061003
1061004
1061005
1061006
1061007
1061008
1061022
1061023
New Part
number
Old Part
Description
number
804013 RFOU 6/10KV 1X 630/40mm² P3/P10
804020
804021
804022
804023
20076430
20076152
20086406
20076162
20077823
804029
804030
RFOU 6/10KV 3X 16/32mm² P3/P10
RFOU 6/10KV 3X 25/31mm² P3/P10
RFOU 6/10KV 3X 35/35mm² P3/P10
RFOU 6/10KV 3X 50/31mm² P3/P10
RFOU 6/10KV 3X 70/35mm² P3/P10
RFOU 6/10KV 3X 95/50mm² P3/P10
RFOU 6/10KV 3X 120/60mm² P3/P10
RFOU 6/10KV 3X 150/75mm² P3/P10
RFOU 6/10KV 3X 185/45mm² P3/P10
RFOU 6/10KV 3X 240/53mm² P3/P10
RFOU 6/10KV 3X 300/55mm² P3/P10
Sheath Colour
Stock item
EAN No. DNK
EL No.
RED
-
7021528040135
1061024
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
-
7021528040203
7021528040210
7021528040227
7021528040234
7021528040241
7021528040258
7021528040265
7021528040272
7021528040289
7021528040296
7021528040302
1061009
1061010
1061011
1061012
1061013
1061014
1061015
1061016
1061017
1061018
1061019
Electrical values power cables
Number
of
elements
Cross
section
core,
mm²
Electrical Conductor
Max.
Max.
Cross
type 2
conductor
conductor
section
resistance at resistance at
braid, mm²
20°C,
90°C,
Ohm/km
Ohm/km
Reactance
at 50Hz,
Ohm/km
Reactance
at 60Hz,
Ohm/km
Capacitans
per phase,
nF/km
1
1
1
1
1
1
1
1
1
1
1
16
25
35
50
70
95
120
150
185
240
300
11
11
11
11
16
16
20
19
18
21
29
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
0.154
0.144
0.138
0.132
0.125
0.119
0.116
0.111
0.108
0.104
0.104
0.185
0.173
0.166
0.158
0.150
0.142
0.139
0.133
0.130
0.125
0.124
220
250
270
300
340
380
410
450
480
540
590
1
400
35
STCC
0.0475
0.0606
0.090
0.118
660
1
500
40
STCC
0.0369
0.0471
0.097
0.117
720
1
630
40
STCC
0.0286
0.0365
0.092
0.110
840
3
3
3
3
3
3
3
3
3
3
3
16
25
35
50
70
95
120
150
185
240
300
32
31
35
31
35
50
60
75
45
53
55
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
0.119
0.119
0.114
0.108
0.103
0.098
0.095
0.092
0.092
0.087
0.084
0.143
0.143
0.137
0.130
0.124
0.118
0.114
0.111
0.111
0.104
0.101
220
250
270
300
340
380
410
450
480
540
590
Current
rating IEC
60092-352
Table B.4,
Ampere
Short
circuit
rating 1
second,
Ampere
96
127
157
196
242
293
339
389
444
522
601
690 dc /
670 ac
780 dc /
720 ac
890 dc /
780 ac
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
67
89
110
137
169
205
237
272
311
365
421
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
56000
70000
88200
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
15 x D
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
9xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 49 of 212
Halogen-free, mud resistant MV power cable, RFOU 8,7/15(17,5)kV, P4/P11
Flame retardant halogen-free medium
voltage (MV) cable. Mud resistant
RFOU 8,7/15(17,5) kV
EPR/EPR/TCWB/EVA
NEK TS 606 CodeP4/P11
Operating temperature
Operating Voltage
: 90°C
: 8,7/15(17,5) kV
Standards applied
Application
Fixed installation for medium voltage (MV) power in
both EX- and safe areas, general purposes. For
installation in areas exposed to MUD and
drilling/cleaning fluids. Meets the MUD resistance
requirement in NEK TS 606:2009
IEC 60092-354
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Conductor screen
semiconductive
Insulation
Insulation screen
semicoductive
Tinned stranded and compressed copper (STCC), IEC 60228 class 2
Semiconductive layer (EP-rubber)
R
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour
Subject to change without prior notice
F
EP-rubber, IEC 60092-360 (EPR)
Semiconductive layer (EP-rubber)
Cores are laid up together. Cores are identified by Brown, Black or Grey
threads under and over the metallic screen on each conductor.
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound,
SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 04 RFOU 8,7/15(17,5)KV P4/P11 1 x 300/29
mm2 IEC 60332-3-22
DRAKA 04 = Draka Industrial Cable, Germany
Red
Page 50 of 212
Range and dimensions
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
Diameter
inner
covering,
mm
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
1
22 ± 1.0
0.4
35
1.8
0.4
27.1
1.8
0.4
27.1
1.9
0.4
27.1
1.9
0.4
31.7
2.0
0.4
31.7
2.0
31.0 ±1.5 0.4
31.7
2.1
0.4
31.7
2.2
0.4
36.2
2.3
25
20
6.5
4.5
1.0
1
35
20
7.4
4.5
1.0
1
50
20
8.8
4.5
1.0
1
70
20
10.3
4.5
1.0
1
95
20
12.1
4.5
1.2
1
120
20
13.6
4.5
1.2
1
150
20
15.1
4.5
1.2
23.0 ±
1.5
24.0 ±
1.5
26.0 ±
1.5
28.0 ±
1.5
29.5 ±
1.5
33.0 ±
1.5
35.0 ±
1.5
1
185
20
16.8
4.5
1.2
1
240
25
19.1
4.5
1.2
1
300
29
21.5
4.5
1.2
37.5 ±1.5 0.4
40.7
2.4
1
400
30
25.6
4.5
1.5
42 ± 2.0
0.4
49.8
2.6
3
25
35
6.5
4.5
1.4
0.5
35
2.7
3
35
35
7.4
4.5
1.6
3
50
40
8.8
4.5
1.6
3
70
40
10.3
4.5
1.6
3
95
55
12.1
4.5
1.6
3
120
60
13.6
4.5
1.6
3
150
80
15.1
4.5
1.8
3
185
95
16.8
4.5
1.8
3
240
95
19.1
4.5
1.8
3
300
95
21.5
4.5
1.8
46.5 ±
2.0
49.0 ±
2.0
52.0 ±
2.0
55.5 ±
2.5
59 ± 2.5
62.5 ±
2.5
66.0 ±
2.5
69.5 ±
2.5
74.5 ±
3.0
80.0 ±
3.0
0.5
49.5
2.8
0.5
56.5
2.9
0.5
56.5
3.1
0.5
70.7
3.2
0.5
84.8
3.4
0.6
112
3.5
0.6
122.1
3.7
0.6
122.1
3.9
0.6
122.1
4.0
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
1370
733
1500
824
1700
978
2000
1204
2450
1500
2700
1766
3000
1793
3500
2424
42.0 ±2.5 4300
2996
28.0 ±
1.5
29.0 ±
1.5
30.5 ±
1.5
32.0 ±
1.5
34.5 ±
2.0
36.0 ±
2.0
38.0 ±
2.0
39.5 ±
2.5
44.5 ±
2.5
49.5 ±
2.5
55 ± 3.0
57.5 ±
3.0
61.0 ±
3.0
64.5 ±
3.0
68.5 ±
3.0
72 ± 3.5
76.0 ±
3.5
80.0 ±
4.0
85.5 ±
4.0
91.0 ±
4.0
5000
3612
6250
4772
4800
1864
5400
2152
6100
2667
7250
3344
8500
3998
9750
5166
11150
6321
13200
7606
15650
9114
17800
10420
Ordering information
New Part
number
Old Part
number
804501
804502
804503
804504
804505
804506
804507
804508
804509
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
804511
RFOU 8.7/15KV 1X 25/20mm² P4/P11
RFOU 8.7/15KV 1X 35/20mm² P4/P11
RFOU 8.7/15KV 1X 50/20mm² P4/P11
RFOU 8.7/15KV 1X 70/20mm² P4/P11
RFOU 8.7/15KV 1X 95/20mm² P4/P11
RFOU 8.7/15KV 1X 120/20mm² P4/P11
RFOU 8.7/15KV 1X150/20 P4/P11
RFOU 8.7/15KV 1X 185/20mm² P4/P11
RFOU 8.7/15KV 1X 240/25mm² P4/P11
RFOU 8.7/15KV 1X 300/29mm² P4/P11
RFOU 8.7/15KV 1X 400/30mm² P4/P11
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
-
7021528045017
7021528045024
7021528045031
7021528045048
7021528045055
7021528045062
7021528045079
7021528045086
7021528045093
7021528045109
7021528045116
-
804521
804522
804523
804524
804525
804526
804527
RFOU 8.7/15KV 3X 25/35mm² P4/P11
RFOU 8.7/15KV 3X 35/35mm² P4/P11
RFOU 8.7/15KV 3X 50/40mm² P4/P11
RFOU 8.7/15KV 3X 70/40mm² P4/P11
RFOU 8.7/15KV 3X 95/55mm² P4/P11
RFOU 8.7/15KV 3X 120/60mm² P4/P11
RFOU 8.7/15KV 3X 150/80mm² P4/P11
RED
RED
RED
RED
RED
RED
RED
-
7021528045215
7021528045222
7021528045239
7021528045246
7021528045253
7021528045260
7021528045277
-
20076154
Subject to change without prior notice
Page 51 of 212
New Part
number
Old Part
Description
number
804528 RFOU 8.7/15KV 3X 185/95mm² P4/P11
804529 RFOU 8.7/15KV 3X 240/95mm² P4/P11
804530 RFOU 8.7/15KV 3X 300/95mm² P4/P11
Sheath Colour
Stock item
RED
RED
RED
-
EAN No. DNK
7021528045284
7021528045291
7021528045307
EL No.
-
Electrical values power cables
Number
of
elements
Cross
section
core,
mm²
Electrical Conductor
Max.
Max.
Cross
type 2
conductor
conductor
section
resistance at resistance at
braid, mm²
20°C,
90°C,
Ohm/km
Ohm/km
Reactance
at 50Hz,
Ohm/km
Reactance
at 60Hz,
Ohm/km
Capacitans
per phase,
nF/km
1
1
1
1
1
1
1
1
1
1
25
35
50
70
95
120
150
185
240
300
20
20
20
20
20
20
20
20
25
29
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
0.151
0.145
0.137
0.130
0.125
0.120
0.116
0.113
0.109
0.105
0.181
0.174
0.165
0.156
0.150
0.144
0.140
0.135
0.130
0.126
210
230
250
280
310
340
370
400
440
480
1
400
30
STCC
0.047
0.059
0.101
0.121
550
3
3
3
3
3
3
3
3
3
3
25
35
50
70
95
120
150
185
240
300
35
35
40
40
55
60
80
95
95
95
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
0.127
0.122
0.115
0.109
0.104
0.100
0.097
0.097
0.091
0.088
0.152
0.146
0.138
0.131
0.125
0.121
0.117
0.117
0.109
0.106
210
230
250
280
310
340
370
400
440
480
Current
rating IEC
60092-352
Table B.4,
Ampere
Short
circuit
rating 1
second,
Ampere
127
157
196
242
293
339
389
444
522
601
690 dc /
670 ac
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
89
110
137
169
205
237
272
311
365
421
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
56000
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
15 x D
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
9xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 52 of 212
Halogen-free, mud resistant MV power cable, RFOU 12/20(24)kV, P19/P21
Flame retardant halogen-free medium
voltage (MV) cable. Mud resistant
RFOU 12/20(24) kV
EPR/EPR/TCWB/EVA
NEK TS 606 CodeP19/P21
Operating temperature
Operating Voltage
: 90°C
: 12/20(24) kV
Standards applied
Application
Fixed installation for medium voltage (MV) power in both
EX- and safe areas, general purposes. For installation in
areas exposed to MUD and drilling/cleaning fluids. Meets
the MUD resistance requirement in NEK TS 606:2009
IEC 60092-354
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Conductor screen
semiconductive
Insulation
Insulation screen
semicoductive
Tinned stranded and compressed copper (STCC), IEC 60228 class 2
Semiconductive layer (EP-rubber)
R
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour
Subject to change without prior notice
F
EP-rubber, IEC 60092-360 (EPR)
Semiconductive layer (EP-rubber)
Cores are laid up together. Cores are identified by Brown, Black or Grey
threads under and over the metallic screen on each conductor.
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound,
SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 04 RFOU 12/20(24)KV P19/P21 3 x 95/50
mm2 IEC 60332-3-22
DRAKA 04 = Draka Industrial Cable, Germany
Red
Page 53 of 212
Range and dimensions
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
Diameter
inner
covering,
mm
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
1
16
13
5.2
5.5
1.0
22.5 ±1.0 0.3
1
25
13
6.5
5.5
1.0
24 ±1.0
1
1
1
1
1
1
35
50
70
95
120
150
13
15
13
17
15
15
7.4
8.8
10.3
12.1
13.6
15.1
5.5
5.5
5.5
5.5
5.5
5.5
1.2
1.2
1.2
1.2
1.3
1.3
1
185
18
16.8
5.5
1
240
23
19.1
1
300
28
1
400
3
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
15.3
1.6
1200
495
0.3
15.3
1.7
1300
561
25 ±1.5
26.5 ±1.5
28 ± 1.5
30 ±1.5
31.5 ±1.5
33 ±1.5
0.3
0.3
0.3
0.3
0.3
0.3
15.3
17.8
15.3
20.4
17.8
17.8
1.8
2.0
2.1
2.1
2.1
2.2
1450
1700
2000
2400
2650
3000
671
811
1001
1210
1491
1835
1.4
35 ±1.5
0.3
20.4
2.2
3500
2201
5.5
1.4
37.5 ±1.5 0.3
25.4
2.4
4350
2915
21.5
5.5
1.4
41.0 ±2.0 0.3
30.5
2.6
5200
3640
35
35.0
5.5
1.5
44.8 ±2.0 0.3
40.0
2.6
28 ± 1.5
29.5 ±
1.5
31 ± 2
32.5 ± 2
34 ± 2.0
36 ± 2
38 ± 2
40 ± 2.5
41.5 ±
2.5
45.0 ±
2.5
47.0 ±
3.0
51.5 ±
3.0
6500
4400
16
31
5.2
5.5
1.4
48 ± 2.0
0.4
36.2
2.6
9300
4112
3
25
35
6.5
5.5
1.4
51 ± 2.0
0.4
40.7
2.7
4950
1558
3
35
35
7.4
5.5
1.4
0.4
40.7
2.8
5500
1885
3
50
35
8.8
5.5
1.8
53 ± 2.0
57.0 ±
2.0
0.4
40.7
3.0
6500
2276
3
70
35
10.3
5.5
1.8
60 ± 2.5
0.4
40.7
3.1
7500
2979
3
95
50
12.1
5.5
2.0
0.5
56.5
3.3
9300
4112
3
120
60
13.6
5.5
2.0
0.5
70.7
3.4
10250
4761
3
150
75
15.1
5.5
2.0
0.5
91.9
3.5
11700
5822
3
185
45
16.8
5.5
2.0
0.5
56.5
3.7
12950
6615
3
240
55
19.1
5.5
2.2
0.5
70.7
3.9
15900
8797
64.5 ±
3.0
67.5 ±
3.0
71.0 ±
3.0
75.0 ±
3.5
79.5 ±
3.5
55.5 ±
3.0
58.5 ±
3.0
61 ± 3.0
65.5 ±
3.5
68.5 ±
3.5
73.5 ±
4.0
77 ± 4.0
80.0 ±
4.5
85.0 ±
4.5
90.0 ±
4.5
Ordering information
New Part
number
Old Part
number
804100
804101
804102
804103
20076155
20076158
804106
20099891
20092205
20077821
20076160
804111
804120
804121
804122
804123
804124
804125
804126
804127
20077822
804129
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
RFOU 12/20KV 1X 16/13mm² P19/P21
RFOU 12/20KV 1X 25/13mm² P19/P21
RFOU 12/20KV 1X 35/13mm² P19/P21
RFOU 12/20KV 1X 50/15mm² P19/P21
RFOU 12/20KV 1X 70/13mm² P19/P21
RFOU 12/20KV 1X 95/17mm² P19/P21
RFOU 12/20KV 1X120/15mm² P19/P21
RFOU 12/20KV 1X150/15mm² P19/P21
RFOU 12/20KV 1X185/18mm² P19/P21
RFOU 12/20KV 1X240/23mm² P19/P21
RFOU 12/20KV 1X300/28mm² P19/P21
RFOU 12/20KV 1X400/35mm² P19/P21
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
Yes
Yes
-
7021528041002
7021528041019
7021528041026
7021528041033
7021528041040
7021528041057
7021528041064
7021528041071
7021528041088
7021528041095
7021528041101
7021528041118
1061035
1061038
-
RFOU 12/20KV 3X 16/31mm² P19/P21
RFOU 12/20KV 3X 25/35mm² P19/P21
RFOU 12/20KV 3X 35/35mm² P19/P21
RFOU 12/20KV 3X 50/35mm² P19/P21
RFOU 12/20KV 3X 70/35mm² P19/P21
RFOU 12/20KV 3X 95/50mm² P19/P21
RFOU 12/20KV 3X120/60mm² P19/P21
RFOU 12/20KV 3X150/75mm² P19/P21
RFOU 12/20kV 3X 185/45mm² P19/P21
RFOU 12/20KV 3X240/55mm² P19/P21
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
-
7021528041200
7021528041217
7021528041224
7021528041231
7021528041248
7021528041255
7021528041262
7021528041279
7021528041286
7021528041293
-
Subject to change without prior notice
Page 54 of 212
Electrical values power cables
Number
of
elements
Cross
section
core,
mm²
Electrical Conductor
Max.
Max.
Cross
type 2
conductor
conductor
section
resistance at resistance at
braid, mm²
20°C,
90°C,
Ohm/km
Ohm/km
Reactance
at 50Hz,
Ohm/km
Reactance
at 60Hz,
Ohm/km
Capacitans
per phase,
nF/km
1
1
1
1
1
1
1
1
1
1
1
16
25
35
50
70
95
120
150
185
240
300
13
13
13
15
13
17
15
15
18
23
28
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
1.479
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
0.164
0.154
0.149
0.140
0.133
0.127
0.124
0.119
0.116
0.112
0.108
0.197
0.185
0.178
0.169
0.160
0.152
0.149
0.142
0.139
0.134
0.130
170
190
200
220
250
270
300
320
340
380
410
1
400
35
STCC
0,0475
0,0606
0.105
0.126
490
3
3
3
3
3
3
3
3
3
3
16
25
35
50
70
95
120
150
185
240
31
35
35
35
35
50
60
75
45
55
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.143
0.133
0.128
0.121
0.115
0.109
0.105
0.102
0.099
0.095
0.172
0.160
0.153
0.145
0.135
0.131
0.126
0.122
0.118
0.114
170
190
200
220
250
270
300
320
340
380
Current
rating IEC
60092-352
Table B.4,
Ampere
Short
circuit
rating 1
second,
Ampere
96
127
157
196
242
293
339
389
444
522
601
690 dc /
670 ac
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
67
89
110
137
169
205
237
272
311
365
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
56000
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
15 x D
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
9xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 55 of 212
Halogen-free, mud resistant MV power cable, RFOU 18/30(36)kV, P20/P22
Flame retardant halogen-free medium voltage
(MV) cable. Mud resistant
RFOU 18/30(36) kV
EPR/EPR/TCWB/EVA
NEK 606 CodeP20/P22
Operating temperature
Operating Voltage
: 90°C
: 18/30(36) kV
Standards applied
Application
Fixed installation for medium voltage (MV) power in both
EX- and safe areas, general purposes. For installation in
areas exposed to MUD and drilling/cleaning fluids.
IEC 60092-354
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Tinned stranded and compressed copper (STCC), IEC 60228 class 2
Conductor screen
semiconductive
Insulation
Insulation screen
semicoductive
Semiconductive layer (EP-rubber)
R
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour
Subject to change without prior notice
F
EP-rubber, IEC 60092-360 (EPR)
Semiconductive layer (EP-rubber)
Cores are laid up together. Cores are identified by Brown, Black or Grey
threads under and over the metallic screen on each conductor.
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound,
SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 04 RFOU 18/30(36)KV P20/P22 3x 120/60
mm2 IEC 60332-3-22
DRAKA 04 = Draka Industrial Cable, Germany
Red
Page 56 of 212
Range and dimensions
Cross Cross
Number
Conductor Insulation
section section
of
Diameter, Thickness,
core,
screen,
elements
mm
mm
mm²
mm²
Thickness
Inner
covering,
mm
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
1
1
1
1
1
1
1
1
50
70
95
120
150
185
240
300
25
30
30
20
30
30
40
35
8.8
10.3
12,1
13,6
15.1
16.8
19.1
21,5
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8,0
1,5
1,5
1,5
1.5
1,5
1.5
1,5
1,5
32.0±1.5
33,5±2,0
35,0±2.0
37.0±2.5
39,0±2.5
40.0±2.5
42.0±2.5
45,0±2,5
0.4
0,4
0,4
0.4
0,4
0.4
0.4
0,4
36.2
36.2
40.7
40.7
45.2
49.8
49.8
54.3
2.0
2,2
2,2
2.4
2,3
2.5
2.4
2,6
38.5±2.0
40,0±3.0
42,0±3.0
44.0±3.0
45,5±3.0
47.5±3.0
50.0±3.0
53,0+-3,5
2500
3000
3400
3500
3900
4600
5400
6200
1119
1463
1698
1939
2280
2675
3250
3867
3
3
3
3
35
70
95
120
45
85
90
95
7.4
10.3
12.1
13.6
8.0
8.0
8.0
8.0
1,8
1,8
1.8
2,0
65.0±2.5
70.0±2.5
74.0±2.5
78.0±2.5
0,6
0,6
0.6
0,6
112
122
122
122
3.5
3,7
3.6
3.8
74.5±3.5
80.5±3.5
85.0±3.5
88,0±4,0
7750
10500
11850
13000
2879
4244
5088
5403
Ordering information
New Part
number
Old Part
number
804303
804304
804305
20099892
804307
804308
804309
20077940
804322
804324
804325
804326
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
RFOU 18/30KV 1x 50/25mm² P20/P22
RFOU 18/30KV 1x 70/30mm² P20/P22
RFOU 18/30KV 1x 95/30mm² P20/P22
RFOU 18/30KV 1x 120/20mm² P20/P22
RFOU 18/30KV 1x 150/ 30mm² P20/P22
RFOU 18/30KV 1x 185/ 30mm² P20/P22
RFOU 18/30KV 1x 240/40mm² P20/P22
RFOU 18/30KV 1x 300/35mm² P20/P22
RED
RED
RED
RED
RED
RED
RED
RED
-
7021528043037
7021528043044
7021528043051
7021528043068
7021528043075
7021528043082
7021528043099
7021528043105
-
RFOU 18/30KV 3x 35/45mm² P20/P22
RFOU 18/30KV 3x 70/85mm² P20/P22
RFOU 18/30KV 3x 95/90mm² P20/P22
RFOU 18/30KV 3x 120/95mm² P20/P22
RED
RED
RED
RED
-
7021528043228
7021528043242
7021528043259
7021528043266
-
Electrical values power cables
Number of Cross
elements section
core,
mm²
Cross
section
screen,
mm²
Conductor
type 2
Max.
Max.
conductor
conductor
resistance at resistance at
20°C,
90°C,
Ohm/km
Ohm/km
Reactance
at 50Hz,
Ohm/km
Reactance
at 60Hz,
Ohm/km
Capacitans
per phase,
nF/km
Current
rating IEC
60092-352
Table B.4,
Ampere
Short
circuit
rating 1
second,
Ampere
1
1
1
1
1
1
1
1
50
70
95
120
150
185
240
300
25
30
30
20
30
30
40
35
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
0.391
0.270
0.195
0.154
0.126
0.097
0,0762
0.0607
0.499
0.344
0.249
0.193
0.161
0.122
0,0972
0.0774
0.152
0.145
0.138
0.133
0,129
0.125
0.120
0.115
0.182
0.174
0.165
0.160
0,154
0.149
0.143
0.135
180
190
210
190
250
265
290
270
196
242
293
339
389
444
522
601
7000
9800
13300
16800
21000
25900
33600
42000
3
3
3
3
35
70
95
120
45
85
90
95
STCC
STCC
STCC
STCC
0.529
0.270
0.195
0.154
0.675
0.344
0.249
0.196
0.141
0,126
0.117
0.115
0.170
0,151
0.141
0.135
160
190
180
230
110
169
205
237
4900
9800
13300
16800
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
15 x D
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
9xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 57 of 212
Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12
Fire resistant, flame retardant halogen-free
power cable. Mud resistant
BFOU 0,6/1(1,2)kV
MGT/EPR/EPR/TCWB/EVA
NEK TS 606 CodeP5/P12
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
IEC 60092-353
Fixed installation for power, control and lighting in both IEC 60228 class 2
IEC 60092-360
EX (Zone 0, 1 & 2)- and safe areas, emergency and
critical systems where requirement for fire resistance IEC 60092-360
IEC 60332-1-2
exists. For installation in areas exposed to MUD and
IEC 60332-3-22
drilling/cleaning fluids. Meets the MUD resistance
IEC 60331-1, -2, -21
requirement in NEK TS 606:2009.
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
B
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2
(IEC 60092-360)
E.g. "meter" "year" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX FLAME IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**)
IEC 60332-3-22
DRAKA 01 = Draka Norsk Kabel
Black
Marking text
Manufacturing unit
Outer sheath colour
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
**) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes
Subject to change without prior notice
Page 58 of 212
Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60445 Ed 5.0 2010-08
Range and dimensions
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
1
16
4
5.15
1.0
1.1
0.2
1
25
6
6.45
1.2
1.1
10 ± 0.8
11.5 ±
0.8
1
35
6
7.65
1.2
1.1
1
50
10
9.0
1.4
1.1
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
5.3
1.2
370
198
0.3
8.5
1.3
530
314
13 ± 0.8
0.3
10.2
1.3
660
413
15 ± 0.8
0.3
12.7
1.4
13 ± 0.8
15.5 ±
0.8
16.5 ±
0.8
18.5 ±
0.8
870
559
0.3
12.7
1.4
20.5 ± 1
1120
756
0.3
15.3
1.5
23 ± 1
1430
996
0.3
0.3
0.3
0.3
15.3
17.8
17.8
20.4
1.6
1.7
1.7
1.8
25 ± 1
27.5 ± 1
29.5 ± 1
33 ± 1.5
1730
2120
2500
3150
1231
1535
1839
2365
0.3
22.9
1.9
36 ± 1.5
3890
2984
10 ± 0.8
10.5 ±
0.8
11.5 ±
0.8
0.2
5.3
1.2
80
8.5
1.3
360
125
0.3
10.2
1.3
13 ± 0.8
14.5 ±
0.8
15.5 ±
0.8
16.5 ±
0.8
17 ± 0.8
21.5 ± 1
25 ± 1
29 ± 1
31.5 ±
1.5
32.5 ±
1.5
285
0.3
410
156
480
170
540
800
1090
1440
215
318
440
577
1740
671
1860
741
360
125
410
156
480
170
16.5 ±
0.8
18.5 ±
0.8
20.5 ± 1
23 ± 1
25 ± 1
28 ± 1
30.5 ±
1.5
1
70
10
10.85
1.4
1.1
1
95
10
12.60
1.6
1.1
1
1
1
1
120
150
185
240
10
10
10
16
14.20
15.90
17.70
20.15
1.6
1.8
2.0
2.2
1.2
1.2
1.2
1.2
1
300
16
22.60
2.4
1.2
2
1.5
4
1.6
1.0
1.1
3
1.5
6
1.6
1.0
1.1
4
1.5
6
1.6
1.0
1.1
5
1.5
6
1.6
1.0
1.1
13 ± 0.8
0.3
10.2
1.4
7
12
19
27
1.5
1.5
1.5
1.5
6
10
10
16
1.6
1.6
1.6
1.6
1.0
1.0
1.0
1.0
1.1
1.2
1.2
1.2
13 ± 0.8
17 ± 0.8
20.5 ± 1
24 ± 1
0.3
0.3
0.3
0.3
11.9
15.3
17.8
20.4
1.4
1.6
1.7
1.9
32
1.5
16
1.6
1.0
1.4
26.5 ± 1
0.3
22.9
2
37
1.5
16
1.6
1.0
1.4
27.5 ± 1
0.3
22.9
2
3G
1.5
-
1.6
1.0
1.1
0.3
8.5
1.3
4G
1.5
-
1.6
1.0
1.1
0.3
10.2
1.3
5G
1.5
-
1.6
1.0
1.1
13 ± 0.8
0.3
10.2
1.4
2
2.5
6
2.0
1.0
1.1
11 ± 0.8
0.3
8.5
1.3
14.5 ±
0.8
370
129
0.3
10.2
1.3
15 ± 0.8
420
169
0.3
10.2
1.3
480
192
0.3
0.3
0.3
0.3
0.3
11.9
11.9
17.8
20.4
22.9
1.4
1.4
1.6
1.8
2
570
630
990
1370
1860
231
277
450
636
844
0.4
36.2
2.2
2510
1204
3
2.5
6
2.0
1.0
1.1
4
2.5
6
2.0
1.0
1.1
5
7
12
19
27
2.5
2.5
2.5
2.5
2.5
6
6
10
16
16
2.0
2.0
2.0
2.0
2.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.2
1.2
1.4
37
2.5
25
2.0
1.0
1.4
Subject to change without prior notice
10.5 ±
0.8
11.5 ±
0.8
11.5 ±
0.8
12.5 ±
0.8
14 ± 0.8
14 ± 0.8
19 ± 0.8
22.5 ± 1
27 ± 1
30.5 ±
1.5
14.5 ±
0.8
15.5 ±
0.8
16.5 ±
0.8
16.5 ±
0.8
18 ± 0.8
18 ± 0.8
23 ± 1
27 ± 1
32 ± 1.5
36.5 ±
1.5
Page 59 of 212
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
3G
2.5
-
2.0
1.0
1.1
4G
2.5
-
2.0
1.0
1.1
5G
7G
2.5
2.5
-
2.0
2.0
1.0
1.0
1.1
1.1
8G
2.5
-
2.0
1.0
1.1
2
4
6
2.55
1.0
1.1
3
4
6
2.55
1.0
4
4
6
2.55
5
4
6
3G
4
4G
5G
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
11.5 ±
0.8
12.5 ±
0.8
14 ± 0.8
14 ± 0.8
19.5 ±
0.8
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
15 ± 0.8
420
169
0.3
10.2
1.3
0.3
10.2
1.3
0.3
0.3
11.9
11.9
0.3
12 ± 0.8
1.1
1.0
1.1
2.55
1.0
1.1
-
2.55
1.0
4
-
2.55
4
-
2.55
2
3
6
6
6
6
4
6
3G
480
192
1.4
1.4
16.5 ±
0.8
18 ± 0.8
18 ± 0.8
570
630
231
277
15.3
1.5
23.5 ± 1
790
333
0.3
10.2
1.3
450
173
13 ± 0.8
0.3
10.2
1.3
510
210
14 ± 0.8
15.5 ±
0.8
0.3
11.9
1.4
610
263
0.3
11.9
1.4
690
300
1.1
13 ± 0.8
0.3
10.2
1.3
510
210
1.0
1.1
11.9
1.4
610
263
1.1
14 ± 0.8
15.5 ±
0.8
0.3
1.0
0.3
11.9
1.4
690
300
3.15
3.15
1.0
1.0
1.1
1.1
0.3
0.3
10.2
11.9
1.4
1.4
209
281
3.15
1.0
1.1
0.3
11.9
1.4
17 ± 0.8
18 ± 0.8
19.5 ±
0.8
530
630
6
13 ± 0.8
14 ± 0.8
15.5 ±
0.8
720
335
6
-
3.15
1.0
1.1
0.3
11.9
1.4
281
6
-
3.15
1.0
1.1
0.3
11.9
1.4
720
335
5G
6
-
3.15
1.0
1.1
0.3
13.6
1.5
18 ± 0.8
19.5 ±
0.8
21.5 ± 1
630
4G
14 ± 0.8
15.5 ±
0.8
17 ± 0.8
880
406
2
3
4
10
10
10
10
10
10
4.05
4.05
4.05
1.0
1.0
1.0
1.1
1.1
1.1
15 ± 0.8
16 ± 0.8
18 ± 0.8
0.3
0.3
0.3
11.9
11.9
13.6
1.4
1.5
1.5
19 ± 0.8
20 ± 1
22 ± 1
690
810
970
299
390
496
3G
4G
5G
10
10
10
-
4.05
4.05
4.05
1.0
1.0
1.0
1.1
1.1
1.2
16 ± 0.8
18 ± 0.8
20 ± 1
0.3
0.3
0.3
11.9
13.6
15.3
1.5
1.5
1.6
20 ± 1
22 ± 1
24 ± 1
810
970
1180
388
496
603
2
16
16
5.15
1.0
1.1
0.5
21.2
1.5
22 ± 1
990
501
3
16
16
5.15
1.0
1.1
4
5
16
16
16
16
5.15
5.15
1.0
1.0
1.2
1.2
3G
16
-
5.15
1.0
1.1
4G
5G
16
16
-
5.15
5.15
1.0
1.0
2
3
4
25
25
25
16
16
16
6.45
6.45
6.45
3G
4G
5G
25
25
25
-
2
3
4
35
35
35
3G
4G
5G
15.5 ±
0.8
16.5 ±
0.8
18 ± 0.8
19.5 ±
0.8
16.5 ±
0.8
18 ± 0.8
19.5 ±
0.8
17.5 ±
0.8
18.5 ±
0.8
20.5 ± 1
23 ± 1
0.4
22.6
1.5
23 ± 1
1170
660
0.4
0.3
22.6
20.4
1.6
1.7
25.5 ± 1
27.5 ± 1
1410
1640
806
930
0.3
15.3
1.5
22.5 ± 1
1090
588
1.2
1.2
18.5 ±
0.8
20.5 ± 1
23 ± 1
0.3
0.3
15.3
17.8
1.6
1.7
25 ± 1
27.5 ± 1
1330
1610
734
905
1.2
1.2
1.2
1.2
1.2
1.2
21 ± 1
22.5 ± 1
25 ± 1
0.4
0.3
0.3
22.6
20.4
20.4
1.6
1.7
1.8
26 ± 1
27 ± 1
29.5 ± 1
1370
1600
1960
685
894
1125
6.45
6.45
6.45
1.2
1.2
1.2
1.2
1.2
1.2
22.5 ± 1
25 ± 1
27.5 ± 1
0.3
0.3
0.3
17.8
17.8
20.4
1.7
1.8
1.8
27 ± 1
29.5 ± 1
32 ± 1.5
1580
1930
2290
869
1100
1356
16
16
16
7.65
7.65
7.65
1.2
1.2
1.2
1.2
1.2
1.2
23.5 ± 1
25 ± 1
28 ± 1
0.3
0.3
0.3
20.4
20.4
20.4
1.7
1.8
1.9
28 ± 1
30 ± 1.5
33 ± 1.5
1640
2000
2460
828
1142
1456
35
35
-
7.65
7.65
1.2
1.2
1.2
1.2
25 ± 1
28 ± 1
0.3
0.3
17.8
20.4
1.8
1.9
1980
2460
1117
1456
35
-
7.65
1.2
1.4
31 ± 1.5
0.3
22.9
2
30 ± 1.5
33 ± 1.5
36.5 ±
1.5
3000
1795
Subject to change without prior notice
Page 60 of 212
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
2
50
25
9.0
1.4
1.4
27.5 ± 1
0.4
31.7
1.8
3
50
25
9.0
1.4
1.2
29 ± 1
0.4
31.7
1.9
4
50
25
9.0
1.4
1.4
32.5 ±
1.5
0.4
31.7
2
3G
50
-
9.0
1.4
1.2
0.3
22.9
4G
50
-
9.0
1.4
1.4
0.3
5G
50
-
9.0
1.4
1.4
2
70
35
10.85
1.4
1.6
3
70
35
10.85
1.4
1.4
4
70
35
10.85
1.4
1.4
3G
70
-
10.85
1.4
1.4
4G
5G
70
70
-
10.85
10.85
1.4
1.4
3
4
95
95
50
50
12.60
12.60
3G
4G
5G
95
95
95
-
3
120
4
120
4G
29 ± 1
32.5 ±
1.5
36 ± 1.5
31.5 ±
1.5
33.5 ±
1.5
37 ± 1.5
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
2270
1181
2730
1617
38 ± 1.5
3370
2052
1.9
34 ± 1.5
2640
1531
22.9
2
38 ± 1.5
3280
1968
0.4
36.2
2.2
42 ± 2
4110
2531
0.6
50.9
2
38 ± 1.5
3190
1783
32.5 ±
1.5
34.5 ±
1.5
0.5
49.5
2
39 ± 1.5
3760
2386
0.4
45.2
2.2
43 ± 2
4600
2977
3520
2150
4510
5440
2888
3566
0.3
25.4
2
1.4
1.4
33.5 ±
1.5
37 ± 1.5
41 ± 2
0.4
0.4
36.2
40.7
2.2
2.3
38.5 ±
1.5
43 ± 2
47 ± 2
1.6
1.6
1.4
1.6
38 ± 1.5
42.5 ± 2
0.6
0.5
61.1
63.6
2.2
2.4
44.5 ± 2
49.5 ± 2
4930
6130
3169
4022
12.60
12.60
12.60
1.6
1.6
1.6
1.4
1.6
1.6
38 ± 1.5
42.5 ± 2
47 ± 2
0.4
0.4
0.4
36.2
40.7
45.2
2.2
2.4
2.6
44 ± 2
49 ± 2
54 ± 2.5
4640
5890
7130
2901
3794
4688
60
14.20
1.6
1.4
41.5 ± 2
0.6
71.3
2.4
3976
14.20
1.6
1.6
46.5 ± 2
0.6
71.3
2.5
48.5 ± 2
53.5 ±
2.5
6020
60
7460
5060
120
-
14.20
1.6
1.6
46.5 ± 2
0.4
45.2
2.5
53 ± 2.5
7170
4781
4G
150
-
15.90
1.8
1.6
52 ± 2.5
0.5
49.5
2.7
5G
150
-
15.90
1.8
1.8
58 ± 2.5
0.5
63.6
4G
185
-
17.70
2.0
1.8
57.5 ±
2.5
0.5
56.5
8900
5943
2.9
59.5 ±
2.5
66 ± 3
10900
7450
2.9
65.5 ± 3
10830
7251
Ordering information
New Part
number
Old Part
number
20120052
20110496
800202
20110497
20110498
20110499
20110500
20110501
20110502
20110503
20109432
20110504
20110507
20110508
20110509
20110510
20109433
20110511
20110512
800227
Description
Sheath
Colour
Stock item
EAN No. DNK
EL No.
BFOU 0.6/1kV 1X 16/4mm² P5/P12
BFOU 0.6/1kV 1X 25/6mm² P5/P12
BFOU 0.6/1kV 1X 35/6mm² P5/P12
BFOU 0.6/1kV 1X 50/10 P5/P12
BFOU 0.6/1kV 1X 70/10 P5/P12
BFOU 0.6/1kV 1X 95/10 P5/P12
BFOU 0.6/1kV 1X 120/10 P5/P12
BFOU 0.6/1kV 1X 150/10 P5/P12
BFOU 0.6/1kV 1X 185/10 P5/P12
BFOU 0.6/1kV 1X 240/16 P5/P12
BFOU 0.6/1kV 1X 300/16 P5/P12
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
Yes
Yes
Yes
Yes
Yes
7021528002003
7021528002010
7021528002027
7021528002034
7021528002041
7021528002058
7021528002065
7021528002072
7021528002089
7021528002096
7021528002102
1043605
1043608
1043609
1043610
1043611
1043612
1043613
1043615
BFOU 0.6/1kV 2X 1.5/4 P5/P12
BFOU 0.6/1kV 3X 1.5/6 P5/P12
BFOU 0.6/1kV 4X 1.5/6 P5/P12
BFOU 0.6/1kV 5X 1.5/6 P5/P12
BFOU 0.6/1kV 7X 1.5/6 P5/P12
BFOU 0.6/1kV 12X 1.5/10 P5/P12
BFOU 0.6/1kV 19X 1.5/10 P5/P12
BFOU 0.6/1kV 27X 1.5/16 P5/P12
BFOU 0.6/1kV 32X 1.5/16 P5/P12
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
Yes
Yes
Yes
Yes
Yes
Yes
-
7021528002157
7021528002188
7021528002195
7021528002201
7021528002218
7021528002225
7021528002232
7021528002249
7021528002270
1043620
1043640
1043660
1043705
1043707
1043712
1043719
1043727
-
Subject to change without prior notice
Page 61 of 212
New Part
number
20109434
Old Part
number
BFOU 0.6/1kV 37X 1.5/16 P5/P12
Sheath
Colour
BLACK
-
7021528002256 1043737
20110505
20110506
20110513
BFOU 0.6/1kV 3G 1.5mm² P5/P12
BFOU 0.6/1kV 4G 1.5mm² P5/P12
BFOU 0.6/1kV 5G 1.5mm² P5/P12
BLACK
BLACK
BLACK
-
7021528002164 1043619
7021528002171 7021528002263 -
20110515
20110517
20110519
20121182
20110520
20110521
20110522
20112294
20109435
BFOU 0.6/1kV 2X 2.5/6 P5/P12
BFOU 0.6/1kV 3X 2.5/6 P5/P12
BFOU 0.6/1kV 4X 2.5/6 P5/P12
BFOU 0.6/1kV 5X 2.5/6 P5/P12
BFOU 0.6/1kV 7X 2.5/6 P5/P12
BFOU 0.6/1kV 12X 2.5/10 P5/P12
BFOU 0.6/1kV 19X 2.5/16 P5/P12
BFOU 0.6/1kV 27X 2.5/16 P5/P12
BFOU 0.6/1kV 37X 2.5/25 P5/P12
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
Yes
Yes
Yes
Yes
-
7021528002294
7021528002324
7021528002355
7021528002348
7021528002379
7021528002386
7021528002393
7021528002409
7021528002416
1043621
1043641
1043661
1043757
1043762
1043769
1043777
1043787
20110516
20110518
20110523
20110514
BFOU 0.6/1kV 3G 2.5mm² P5/P12
BFOU 0.6/1kV 4G 2.5mm² P5/P12
BFOU 0.6/1kV 5G 2.5mm² P5/P12
BFOU 0.6/1kV 7G 2.5mm² P5/P12
BFOU 0.6/1kV 8G 2.5mm² P5/P12
BLACK
BLACK
BLACK
BLACK
BLACK
Yes
Yes
-
7021528002300
7021528002331
7021528002423
7021528002287
7021528002362
1043639
1043659
1043755
-
20110526
20110527
20110528
20110529
BFOU 0.6/1kV 2X 4/6mm² P5/P12
BFOU 0.6/1kV 3X 4/6mm² P5/P12
BFOU 0.6/1kV 4X 4/6mm² P5/P12
BFOU 0.6/1kV 5X 4/6mm² P5/P12
BLACK
BLACK
BLACK
BLACK
Yes
Yes
Yes
-
7021528002454
7021528002461
7021528002478
7021528002485
1043622
1043642
1043662
-
20110529
20110524
20110525
BFOU 0.6/1kV 3G 4mm² P5/P12
BFOU 0.6/1kV 4G 4mm² P5/P12
BFOU 0.6/1kV 5G 4mm² P5/P12
BLACK
BLACK
BLACK
Yes
-
7021528002508 7021528002430 7021528002447 -
20110530
20110531
20110532
BFOU 0.6/1kV 2X 6/6mm² P5/P12
BFOU 0.6/1kV 3X 6/6mm² P5/P12
BFOU 0.6/1kV 4X 6/6mm² P5/P12
BLACK
BLACK
BLACK
Yes
Yes
Yes
7021528002515 1043623
7021528002522 1043643
7021528002539 1043663
20110533
20110534
20110535
BFOU 0.6/1kV 3G 6mm² P5/P12
BFOU 0.6/1kV 4G 6mm² P5/P12
BFOU 0.6/1kV 5G 6mm² P5/P12
BLACK
BLACK
BLACK
Yes
-
7021528002546 7021528002553 7021528002560 -
20110536
20110537
20110538
BFOU 0.6/1kV 2X 10/10 P5/P12
BFOU 0.6/1kV 3X 10/10 P5/P12
BFOU 0.6/1kV 4X 10/10 P5/P12
BLACK
BLACK
BLACK
Yes
Yes
Yes
7021528002577 1043624
7021528002584 1043644
7021528002591 1043664
20110539
20110540
20110541
BFOU 0.6/1kV 3G 10mm² P5/P12
BFOU 0.6/1kV 4G 10mm² P5/P12
BFOU 0.6/1kV 5G 10mm² P5/P12
BLACK
BLACK
BLACK
-
7021528002607 7021528002614 7021528002621 -
20109436
20110542
20110543
BFOU 0.6/1kV 2X 16/16 P5/P12
BFOU 0.6/1kV 3X 16/16 P5/P12
BFOU 0.6/1kV 4X 16/16 P5/P12
BFOU 0.6/1kV 5X 16/16 P5/P12
BLACK
BLACK
BLACK
BLACK
Yes
Yes
Yes
-
7021528002638
7021528002645
7021528002652
7021528003161
20110544
20110546
20110545
BFOU 0.6/1kV 3G 16mm² P5/P12
BFOU 0.6/1kV 4G 16mm² P5/P12
BFOU 0.6/1kV 5G 16mm² P5/P12
BLACK
BLACK
BLACK
-
7021528002669 7021528002683 7021528002676 -
20110547
20110548
20110549
BFOU 0.6/1kV 2X 25/16 P5/P12
BFOU 0.6/1kV 3X 25/16 P5/P12
BFOU 0.6/1kV 4X 25/16 P5/P12
BLACK
BLACK
BLACK
Yes
Yes
7021528002690 1043626
7021528002706 1043646
7021528002713 1043666
BFOU 0.6/1kV 3G 25mm² P5/P12
BFOU 0.6/1kV 4G 25mm² P5/P12
BFOU 0.6/1kV 5G 25mm² P5/P12
BLACK
BLACK
BLACK
-
7021528002744 7021528002720 7021528002737 -
BFOU 0.6/1kV 2X 35/16 P5/P12
BFOU 0.6/1kV 3X 35/16 P5/P12
BFOU 0.6/1kV 4X 35/16 P5/P12
BLACK
BLACK
BLACK
Yes
Yes
7021528002751 1043627
7021528002768 1043647
7021528002775 1043667
BFOU 0.6/1kV 3G 35mm² P5/P12
BFOU 0.6/1kV 4G 35mm² P5/P12
BFOU 0.6/1kV 5G 35mm² P5/P12
BLACK
BLACK
BLACK
-
7021528002782 7021528002799 7021528002805 -
800236
800316
800274
800272
800273
20110762
20110550
20110551
800278
800279
20110763
Description
Subject to change without prior notice
Stock item
EAN No. DNK
EL No.
1043625
1043645
1043665
-
Page 62 of 212
New Part
number
20121221
20110552
20110553
Old Part
number
BFOU 0.6/1kV 2X 50/25 P5/P12
BFOU 0.6/1kV 3X 50/25 P5/P12
BFOU 0.6/1kV 4X 50/25 P5/P12
Sheath
Colour
BLACK
BLACK
BLACK
Yes
-
7021528002812 7021528002829 1043648
7021528002836 1043668
BFOU 0.6/1kV 3G 50mm² P5/P12
BFOU 0.6/1kV 4G 50mm² P5/P12
BFOU 0.6/1kV 5G 50mm² P5/P12
BLACK
BLACK
BLACK
-
7021528002867 7021528002850 7021528002843 -
BFOU 0.6/1kV 2X 70/35 P5/P12
BFOU 0.6/1kV 3X 70/35 P5/P12
BFOU 0.6/1kV 4X 70/35 P5/P12
BFOU 0.6/1kV 5X 70/35 P5/P12
BLACK
BLACK
BLACK
BLACK
Yes
-
7021528002874
7021528002881
7021528002898
7021528002935
BFOU 0.6/1kV 3G 70mm² P5/P12
BFOU 0.6/1kV 4G 70mm² P5/P12
BFOU 0.6/1kV 5G 70mm² P5/P12
BLACK
BLACK
BLACK
-
7021528002928 7021528002904 7021528002911 -
BFOU 0.6/1kV 2X 95/50 P5/P12
BFOU 0.6/1kV 3X 95/50 P5/P12
BFOU 0.6/1kV 4X 95/50 P5/P12
BLACK
BLACK
BLACK
Yes
Yes
7021528002942 7021528002959 1043650
7021528002966 1043670
20110764
20109442
BFOU 0.6/1kV 3G 95mm² P5/P12
BFOU 0.6/1kV 4G 95mm² P5/P12
BFOU 0.6/1kV 5G 95mm² P5/P12
BLACK
BLACK
BLACK
-
7021528002997 7021528002973 7021528002980 -
20109443
20120715
BFOU 0.6/1kV 3X 120/60 P5/P12
BFOU 0.6/1kV 4X 120/60 P5/P12
BLACK
BLACK
Yes
-
7021528003017 1043651
7021528003048 -
800306
BFOU 0.6/1kV 4G 120mm² P5/P12
BLACK
-
7021528003062 -
800307
20132888
BFOU 0.6/1kV 4G 150mm² P5/P12
BFOU 0.6/1kV 5G 150mm² P5/P12
BLACK
BLACK
-
7021528003079 7021528003185 -
20121096
BFOU 0.6/1kV 4G 185mm² P5/P12
BLACK
-
7021528003109 -
800286
800285
800284
20110554
20109437
20109438
20109439
800292
800290
800291
20115558
20109440
20109441
800299
Description
Stock item
EAN No. DNK
EL No.
1043629
1043649
1043669
-
Electrical values power cables
Number of
elements
Cross
Electrical
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
section
Cross
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
core, section braid,
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table B.4, second,
mm²
mm²
Ampere
Ampere
1
1
1
1
1
1
1
1
1
1
1
16
25
35
50
70
95
120
150
185
240
300
4
6
6
10
10
10
10
10
10
16
16
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
1.16
0.734
0.529
0.391
0.27
0.195
0.154
0.126
0.1
0.0762
0.0607
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
0.118
0.114
0.108
0.105
0.1
0.097
0.095
0.094
0.092
0.09
0.088
0.142
0.136
0.129
0.126
0.12
0.116
0.114
0.112
0.11
0.108
0.106
96
127
157
196
242
293
339
389
444
522
601
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
2
3
4
5
7
12
19
27
32
37
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
4
6
6
6
6
10
10
16
16
16
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.138
0.138
0.138
0.138
0.138
0.138
0.138
0.138
0.138
0.138
20
16
16
13.5
12
10
8.5
7.5
7
7
210
210
210
210
210
210
210
210
210
210
3G
4G
5G
1.5
1.5
1.5
-
STCC
STCC
STCC
12.2
12.2
12.2
15.6
15.6
15.6
0.115
0.115
0.115
0.138
0.138
0.138
20
16
16
210
210
210
2
3
2.5
2.5
6
6
STCC
STCC
7.56
7.56
9.64
9.64
0.107
0.107
0.129
0.129
26
21
350
350
Subject to change without prior notice
Page 63 of 212
Number of
elements
5
4
7
12
19
27
37
Cross
section
core,
mm²
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Electrical
Conductor
Cross
type 2
section braid,
mm²
6
STCC
6
STCC
6
STCC
10
STCC
16
STCC
16
STCC
25
STCC
Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table B.4, second,
Ampere
Ampere
7.56
9.64
0.107
0.129
17.5
350
7.56
9.64
0.107
0.129
21
350
7.56
9.64
0.107
0.129
15.5
350
7.56
9.64
0.107
0.129
13
350
7.56
9.64
0.107
0.129
11
350
7.56
9.64
0.107
0.129
10
350
7.56
9.64
0.107
0.129
9
350
3G
4G
5G
7G
8G
2.5
2.5
2.5
2.5
2.5
-
STCC
STCC
STCC
STCC
STCC
7.56
7.56
7.56
7.56
7.56
9.64
9.64
9.64
9.64
9.64
0.107
0.107
0.107
0.107
0.107
0.129
0.129
0.129
0.129
0.129
26
21
21
16.5
15.5
350
350
350
350
350
2
3
4
5
4
4
4
4
6
6
6
6
STCC
STCC
STCC
STCC
4.7
4.7
4.7
4.7
5.99
5.99
5.99
5.99
0.100
0.100
0.1
0.1
0.120
0.120
0.120
0.120
34
28
28
23.5
560
560
560
560
3G
4G
5G
4
4
4
-
STCC
STCC
STCC
4.7
4.7
4.7
5.99
5.99
5.99
0.1
0.1
0.1
0.120
0.120
0.120
34
28
28
560
560
560
2
3
4
6
6
6
6
6
6
STCC
STCC
STCC
3.11
3.11
3.11
3.97
3.97
3.97
0.094
0.094
0.094
0.112
0.112
0.112
44
36
36
840
840
840
3G
4G
5G
6
6
6
-
STCC
STCC
STCC
3.11
3.11
3.11
3.97
3.97
3.97
0.094
0.094
0.094
0.112
0.112
0.112
44
36
36
840
840
840
2
3
4
10
10
10
10
10
10
STCC
STCC
STCC
1.84
1.84
1.84
2.35
2.35
2.35
0.088
0.088
0.088
0.105
0.105
0.105
61
50
50
1400
1400
1400
3G
4G
5G
10
10
10
-
STCC
STCC
STCC
1.84
1.84
1.84
2.35
2.35
2.35
0.088
0.088
0.088
0.105
0.105
0.105
61
50
50
1400
1400
1400
2
3
4
5
16
16
16
16
16
16
16
16
STCC
STCC
STCC
STCC
1.16
1.16
1.16
1.16
1.48
1.48
1.48
1.48
0.082
0.082
0.082
0.082
0.099
0.099
0.099
0.099
80
67
67
56
2240
2240
2240
2240
3G
4G
5G
16
16
16
-
STCC
STCC
STCC
1.16
1.16
1.16
1.48
1.48
1.48
0.082
0.082
0.082
0.099
0.099
0.099
80
67
67
2240
2240
2240
2
3
4
25
25
25
16
16
16
STCC
STCC
STCC
0.734
0.734
0.734
0.936
0.936
0.936
0.081
0.081
0.081
0.098
0.098
0.098
108
89
89
3500
3500
3500
3G
4G
5G
25
25
25
-
STCC
STCC
STCC
0.734
0.734
0.734
0.936
0.936
0.936
0.081
0.081
0.081
0.098
0.098
0.098
108
89
89
3500
3500
3500
2
3
4
35
35
35
16
16
16
STCC
STCC
STCC
0.529
0.529
0.529
0.675
0.675
0.675
0.078
0.078
0.078
0.094
0.094
0.094
133
110
110
4900
4900
4900
3G
4G
5G
35
35
35
-
STCC
STCC
STCC
0.529
0.529
0.529
0.675
0.675
0.675
0.078
0.078
0.078
0.094
0.094
0.094
133
110
110
4900
4900
4900
2
3
4
50
50
50
25
25
25
STCC
STCC
STCC
0.391
0.391
0.391
0.499
0.499
0.499
0.078
0.078
0.078
0.094
0.093
0.093
167
137
137
7000
7000
7000
3G
4G
50
50
-
STCC
STCC
0.391
0.391
0.499
0.499
0.078
0.078
0.093
0.093
167
137
7000
7000
Subject to change without prior notice
Page 64 of 212
Number of
elements
5G
Cross
Electrical
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
section
Cross
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
core, section braid,
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table B.4, second,
mm²
mm²
Ampere
Ampere
50
STCC
0.391
0.499
0.078
0.093
137
7000
2
3
4
70
70
70
35
35
35
STCC
STCC
STCC
0.27
0.27
0.27
0.344
0.344
0.344
0.075
0.077
0.077
0.092
0.092
0.092
206
169
169
9800
9800
9800
3G
4G
5G
70
70
70
-
STCC
STCC
STCC
0.27
0.27
0.27
0.344
0.344
0.344
0.075
0.075
0.075
0.092
0.092
0.092
206
169
169
9800
9800
9800
3
4
95
95
50
50
STCC
STCC
0.195
0.195
0.249
0.249
0.075
0.075
0.090
0.090
205
205
13300
13300
3G
4G
5G
95
95
95
-
STCC
STCC
STCC
0.195
0.195
0.195
0.249
0.249
0.249
0.075
0.075
0.075
0.090
0.090
0.090
249
205
205
13300
13300
13300
3
4
120
120
60
60
STCC
STCC
0.154
0.154
0.196
0.196
0.073
0.073
0.088
0.088
237
237
16800
16800
4G
120
-
STCC
0.154
0.196
0.073
0.088
237
16800
4G
150
-
STCC
0.126
0.161
0.073
0.088
272
21000
4G
185
-
STCC
0.1
0.128
0.073
0.088
311
25900
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 65 of 212
Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12,
double braided
Fire resistant, flame retardant halogen-free
power cable. Mud resistant. Double braided.
BFOU 0,6/1(1,2)kV
MGT/EPR/EPR/TCWB/EVA
NEK TS 606 CodeP5/P12
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
IEC 60092-353
Fixed installation for power, control and lighting in both IEC 60228 class 2
IEC 60092-360
EX (Zone 0, 1 & 2)- and safe areas, emergency and
critical systems where requirement for fire resistance IEC 60092-360
IEC 60332-1-2
exists. For installation in areas exposed to MUD and
IEC 60332-3-22
drilling/cleaning fluids. Meets the MUD resistance
IEC 60331-1, -2, -21
requirement in NEK TS 606:2009.
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
B
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoplastic compound
PET tape + rubberized Polyamide tape
O
Two layers of tinned copper wire braid (double braid)
PET tape + rubberized Polyamide tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2
(IEC 60092-360)
E.g. "meter" "year" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX FLAME IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22
DRAKA 01 = Draka Norsk Kabel
Black
Marking text
Manufacturing unit
Outer sheath
colour
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
**) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes
Subject to change without prior notice
Page 66 of 212
Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60445 Ed 5.0 2010-08
Range and dimensions
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
2
150
75
18.1
1.8
1.8
44 ± 2
0.4
90.5
2.5
5390
3622
3
150
75
15.90
1.8
1.4
46.5 ± 2
0.4
86
2.6
7510
4992
4
150
75
15.90
1.8
1.6
52 ± 2.5
0.5
99
2.8
52 ± 2.5
54.5 ±
2.5
61 ± 3
9470
6451
3
185
95
17.70
2.0
1.6
0.5
127.2
2.8
60.5 ± 3
9350
6295
4
185
95
17.7
2.0
1.8
51 ± 2.5
57.5 ±
2.5
0.6
122.1
2.9
68±3
11620
7750
2
3
240
240
120
120
20.2
20.2
2.2
2.2
1.8
1.8
54 ± 2.5
58 ± 2.5
0.6
0.6
142.5
142.5
2.9
3
64 ± 3
68.5 ± 3
9110
11870
5845
8042
Ordering information
New Part
number
Old Part
number
800317
Description
Sheath
Colour
Stock
item
EAN No. DNK
EL No.
20109444
20117948
BFOU 0.6/1kV 2X 150/75 P5/P12
BFOU 0.6/1kV 3X 150/75 P5/P12
BFOU 0.6/1kV 4X 150/75 P5/P12
BLACK
BLACK
BLACK
Yes
-
7021528003178
7021528003024
7021528003093
1043652
-
20110765
20118466
BFOU 0.6/1kV 3X 185/95 P5/P12
BFOU 0.6/1kV 4X 185/95 P5/P12
BLACK
BLACK
-
7021528003925
7021528003918
-
BFOU 0.6/1kV 2X 240/120 P5/P12
BFOU 0.6/1kV 3X 240/120 P5/P12
BLACK
BLACK
-
7021528003154
7021528003147
-
800315
800314
Electrical values power cables
Number of
elements
Cross
Electrical Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
section
Cross
type
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
core, section braid,
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table B.4, second,
mm²
mm²
Ampere
Ampere
2
3
4
150
150
150
75
75
75
KGTFR
KGTFR
KGTFR
0.126
0.126
0.126
0.161
0.161
0.161
0.072
0.073
0.073
0.088
0.088
0.088
331
272
272
21000
21000
21000
3
4
185
185
95
95
KGTFR
KGTFR
0.1
0.1
0.128
0.128
0.073
0.073
0.088
0.088
311
311
25900
25900
2
3
240
240
120
120
KGTFR
KGTFR
0.0762
0.0762
0.0972
0.0972
0.074
0.074
0.089
0.089
444
365
33600
33600
Subject to change without prior notice
Page 67 of 212
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 68 of 212
Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12,
large single core cables
Fire resistant, flame retardant halogen-free
power cable. Mud resistant. Single core
cable.
BFOU 0,6/1(1,2)kV
MGT/EPR/EPR/TCWB/EVA
NEK TS 606 CodeP5/P12
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
Fixed installation for power, control and lighting in
both EX (Zone 0, 1 & 2)- and safe areas,
emergency and critical systems where requirement
for fire resistance exists. For installation in areas
exposed to MUD and drilling/cleaning fluids. Meets
the MUD resistance requirement in NEK TS
606:2009.
IEC 60092-353
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-1, -2, -21
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
B
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2
(IEC 60092-360)
E.g. "meter" "year" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX FLAME IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22
DRAKA 01 = Draka Norsk Kabel
Black
Marking text
Manufacturing unit
Outer sheath
colour
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
**) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes
Subject to change without prior notice
Page 69 of 212
Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60445 Ed 5.0 2010-08
Range and dimensions
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
1
1
1
35 ± 1.5
38 ± 1.5
42 ± 2
2.1
2.2
2.3
41 ± 2
44.5 ± 2
48.5 ± 2
5130
6240
7690
3974
4923
6205
400
500
630
25
25
25
26.00
29.0
32.80
2.6
2.8
2.8
1.4
1.4
1.4
0.4
0.4
0.4
31.7
36.2
40.7
Ordering information
New Part number Old Part number
20132148
800212
800213
Description
Sheath Colour Stock item EAN No. DNK EL No.
BFOU 0.6/1kV 1X 400/25 P5/P12 BLACK
BFOU 0.6/1kV 1X 500/25 P5/P12 BLACK
BFOU 0.6/1kV 1X 630/25 P5/P12 BLACK
-
7021528002119 7021528002126 7021528002133 -
Electrical values power cables
Number of
elements
Cross
Electrical
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
section
Cross
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
core, section braid,
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table B.4, second,
mm²
mm²
Ampere
Ampere
1
400
25
STCC
0.0475
0.0606
0.088
0.105
1
500
25
STCC
0.0369
0.0471
0.086
0.103
1
630
25
STCC
0.0286
0.0365
0.084
0.100
690 dc / 670
ac
780 dc / 720
ac
890 dc / 780
ac
56000
70000
88200
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 70 of 212
Halogen-free, mud resistant insulated conductor UX 1000V, P15
Flame retardant conductors
UX 1000V
Halogen-free, NEK TS 606 Type: P15
Maximum operating
Conductor temperature
Operating voltage
Application
Standards applied
Insulated conductor for earthing and bonding services.
Mud resistant in accordance with NEK TS 606:2009.
IEC:60092-353 &
NEK TS 606:2009
IEC:60228 class 2
IEC:60332-1
IEC:60332-3-22
IEC:60754-1,2
IEC:61034-1,2
: 90°C
: 1000V
- Design guidelines
- Conductor
- Flame retardance
- Flame retardance
- Halogen-free properties
- Smoke density
CONSTRUCTION
CODE LETTER
Conductor
Insulation
U
Unsheathed
X
Tinned, stranded copper, IEC 60228 class 2
PETP-tape.
Flame retardant halogen-free thermoset compound, HF90 (IEC
60092-360).
Marking
E.g; ”meter” ”year” DRAKA NORSK KABEL UX 1000V P15
1x 95 mm² IEC 332-3-22
Colour
Yellow/green
Subject to change without prior notice
Page 71 of 212
RANGE AND DIMENSIONS: UX 1000V Insulated conductor, P15
Conductor area
(mm²)
Conductor
diameter
approx.
(mm)
Insulation
thickness
(mm)
Diameter
over
insulation
(mm)
Weight of
conductor
approx.
(kg/km)
Copper content
approx.
(kg/km)
6
3,15
1,0
5,5±0,8
80
54
10
4,05
1,0
6,5±0,8
120
87
16
5,15
1,0
7,5±0,8
180
143
25
6,4
1,2
9,5±0,8
280
224
35
7,65
1,2
10,5±1,0
370
310
50
9,00
1,4
12,5±1,0
520
430
70
10,85
1,4
14,5±1,0
730
620
95
12,60
1,6
16,5±1,0
970
840
120
14,20
1,6
18,0±1,0
1220
1080
150
15,90
1,8
20,0±1,5
1520
1342
185
17,70
2,0
22,0±1,5
1890
1670
240
20,15
2,2
25,0±1,5
2450
2183
300
22,60
2,4
28,0±1,5
3090
2762
630
32,80
2,8
38,5±2,0
6350
5800
Electrical characteristics:
Conductor area
(mm²)
Max. conductor Max. conductor Current rating
resistance at
resistance at
IEC 60092-352
20°C,
90°C,
Table B.4,
Ohm/km
Ohm/km
Ampere
Short circuit
rating at 1
second,
Ampere
6
3.11
3.97
52
840
10
1.84
2.35
72
1400
16
1.16
1.48
96
2240
25
0.734
0.936
127
3500
35
0.529
0.675
157
4900
50
0.391
0.499
196
7000
70
0.27
0.344
242
9800
95
0.195
0.249
293
13300
120
0.154
0.196
339
16800
150
0.126
0.161
389
21000
185
0.100
0.128
444
25900
240
0.0762
0.0972
522
33600
300
0.0607
0.0774
601
42000
630
0.0286
0.0359
890 dc / 780 ac
88200
Installation recommendations:
In accordance with IEC 60092-352
Minimum bending radius
During installation
Maximum pulling tension
Fixed installed
25N x total
cross section of conductors
8 x cable diameter
Minium installation
temperature
- 20 °C
6 x cable diameter
Subject to change without prior notice
Page 72 of 212
Ordering information:
New Part
number
Old Part
number
Conductor area
(mm²)
Stock item
El-number
(Norway only)
800810
800811
800812
800815
6
10
16
25
35
50
70
95
120
150
185
240
300
630
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-
1045541
1045542
1045543
1045553
1045563
1045573
1045583
1045593
1045603
1045604
-
20109530
20109531
20109532
20109533
20109534
20109535
20109536
20109537
20121097
20109538
Subject to change without prior notice
Page 73 of 212
Halogen-free, fire resistant, unarmoured, mud resistant power cable, BU 0,6/1(1,2)kV,
P17
Fire resistant, flame retardant halogen-free
power cable. Mud resistant
BU 0,6/1(1,2)kV
MGT/EPR/EVA
NEK TS 606 CodeP17
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
Fixed installation for power, control and lighting in
safe areas, emergency and critical systems where
requirement for fire resistance exists. For
installation in areas exposed to MUD and
drilling/cleaning fluids. Meets the MUD resistance
requirement in NEK TS 606:2009. These cables
are double-insulated and Single core cables are
used as battery cables.
IEC 60092-353
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-21
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Armour/screen
Outer sheath
B
U
Marking text
Manufacturing unit
Outer sheath
colour
Subject to change without prior notice
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
No inner covering. (Additional tapes may be applied)
No armour.
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2
(IEC 60092-360)
E.g. "meter" "year" DRAKA 01 BU 0,6/1kV P17 1 x 70 mm2 IEC 60331-21 IEC
60332-3-22
DRAKA 01 = Draka Norsk Kabel,
Black
Page 74 of 212
Core identification power cables
Single core – Black
Two cores - Blue – Brown
Three cores - Brown - Black – Grey
Four cores - Blue - Brown - Black – Grey
Five cores - Blue - Brown - Black - Grey – Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue – Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60445 Ed 5.0 2010-08
Range and dimensions
Number of
elements
Cross section Conductor
core, mm²
Diameter, mm
Insulation
Thickness, mm
Thickness Outer
Sheath, mm
Diameter outer
sheath, mm
Weight of Cable
Approx. (Kg/Km)
Copper content
Approx. (kg/km)
1
1
1
1
1
1
1
1
1
1
1
10
16
25
35
50
70
95
120
150
185
240
4.05
5.15
6.45
7.65
9.0
10.85
12.60
14.20
15.90
17.70
20.15
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
1
1.1
1.1
1.2
1.2
1.3
1.4
1.4
1.5
1.6
1.7
8.5 ± 0.5
10 ± 0.8
11.5 ± 0.8
13 ± 0.8
15 ± 0.8
17 ± 0.8
19.5 ± 0.8
21 ± 1
23.5 ± 1
25.5 ± 1
29 ± 1
165
235
350
460
620
850
1120
1380
1730
2100
2700
91
146
231
314
434
632
847
1082
1360
1664
2165
2
3
7
19
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.0
1.0
1.0
1.0
1.1
1.1
1.2
1.5
10 ± 0.8
10.5 ± 0.8
13 ± 0.8
21 ± 1
150
175
310
740
28
42
98
266
3G
7G
1.5
1.5
1.6
1.6
1.0
1.0
1.1
1.2
10.5 ± 0.8
13 ± 0.8
175
310
42
98
2
3
7
12
19
2.5
2.5
2.5
2.5
2.5
2.0
2.0
2.0
2.0
2.0
1.0
1.0
1.0
1.0
1.0
1.1
1.2
1.3
1.4
1.6
11 ± 0.8
11.5 ± 0.8
14.5 ± 0.8
19.5 ± 0.8
23 ± 1
185
220
400
640
970
46
69
161
276
436
3G
4G
5G
2.5
2.5
2.5
2.0
2.0
2.0
1.0
1.0
1.0
1.2
1.2
1.3
11.5 ± 0.8
13 ± 0.8
14.5 ± 0.8
220
265
340
69
92
115
3
4
2.55
1.0
1.2
13 ± 0.8
295
110
3G
4G
4
4
2.55
2.55
1.0
1.0
1.2
1.3
13 ± 0.8
14.5 ± 0.8
295
370
110
147
2
3
6
6
3.15
3.15
1.0
1.0
1.2
1.2
13.5 ± 0.8
14.5 ± 0.8
310
380
110
164
4G
5G
6
6
3.15
3.15
1.0
1.0
1.3
1.4
16 ± 0.8
18 ± 0.8
480
600
219
273
2
3
10
10
4.05
4.05
1.0
1.0
1.3
1.3
15.5 ± 0.8
16.5 ± 0.8
440
550
182
272
4G
10
4.05
1.0
1.4
18.5 ± 0.8
690
363
3
16
5.15
1.0
1.4
19 ± 0.8
790
438
4G
16
5.15
1.0
1.5
21.5 ± 1
1000
584
3
25
6.45
1.2
1.5
23 ± 1
1190
694
3G
25
6.45
1.2
1.5
23 ± 1
1190
694
Subject to change without prior notice
Page 75 of 212
Number of
elements
3
Cross section Conductor
core, mm²
Diameter, mm
35
7.65
Insulation
Thickness, mm
1.2
Thickness Outer
Sheath, mm
1.7
Diameter outer
sheath, mm
26 ± 1
Weight of Cable
Approx. (Kg/Km)
1550
Copper content
Approx. (kg/km)
942
4G
35
7.65
1.2
1.7
29 ± 1
2000
1256
3
50
9.0
1.4
1.9
30 ± 1.5
2120
1306
3
150
15.9
1.8
2.3
48 ± 2
5910
4091
4G
150
15.9
1.8
2.5
53.5 ± 2.5
7750
5455
Ordering information
New Part
number
Old Part
number
20130809
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
801209
BU 0.6/1kV 1X 10mm² P17
BU 0.6/1kV 1X 16mm² P17
BU 0.6/1kV 1X 25mm² P17
BU 0.6/1kV 1X 35mm² P17
BU 0.6/1kV 1X 50mm² P17
BU 0.6/1kV 1X 70mm² P17
BU 0.6/1kV 1X 95mm² P17
BU 0.6/1kV 1X 120mm² P17
BU 0.6/1kV 1X 150mm² P17
BU 0.6/1kV 1X 185mm² P17
BU 0.6/1kV 1X 240mm² P17
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528012149
7021528012002
7021528012019
7021528012026
7021528012033
7021528012040
7021528012057
7021528012064
7021528012071
7021528012088
7021528012095
1061201
1061203
1061205
1061207
-
801218
801225
801228
BU 0.6/1kV 2X 1.5mm² P17
BU 0.6/1kV 3X 1.5mm² P17
BU 0.6/1kV 7X 1.5mm² P17
BU 0.6/1kV 19X 1.5mm² P17
BLACK
BLACK
BLACK
BLACK
-
7021528012156
7021528012187
7021528012255
7021528012286
-
801224
BU 0.6/1kV 3G 1.5mm² P17
BU 0.6/1kV 7G 1.5mm² P17
BLACK
BLACK
-
7021528012163
7021528012248
-
801233
BU 0.6/1kV 2X 2.5mm² P17
BLACK
-
7021528012330
-
801236
801244
801245
801246
BU 0.6/1kV 3X 2.5mm² P17
BU 0.6/1kV 7X 2.5mm² P17
BU 0.6/1kV 12X 2.5mm² P17
BU 0.6/1kV 19X 2.5mm² P17
BLACK
BLACK
BLACK
BLACK
-
7021528012361
7021528012446
7021528012453
7021528012460
-
20096771
20117121
20131218
BU 0.6/1kV 3G 2.5mm² P17
BU 0.6/1kV 4G 2.5mm² P17
BU 0.6/1kV 5G 2.5mm² P17
BLACK
BLACK
BLACK
Yes
-
7021528012347
7021528012378
7021528012408
-
20109456
BU 0,6/1KV 3X 4 MM2 P17
BLACK
-
7021528012538
-
BU 0.6/1kV 3G 4mm² P17
BU 0.6/1kV 4G 4mm² P17
BLACK
BLACK
-
7021528012545
7021528012569
-
801261
BU 0,6/1KV 2X 6 MM2 P17
BU 0.6/1kV 3X 6mm² P17
BLACK
BLACK
-
7021528012590
7021528012613
-
801263
BU 0.6/1kV 4G 6mm² P17
BU 0.6/1kV 5G 6mm² P17
BLACK
BLACK
-
7021528012620
7021528012637
-
801266
801267
BU 0.6/1kV 2X 10mm² P17
BU 0.6/1kV 3X 10mm² P17
BLACK
BLACK
-
7021528012668
7021528012675
-
BU 0.6/1kV 4G 10mm² P17
BLACK
-
7021528012699
-
20121091
BU 0.6/1kV 3X 16mm² P17
BLACK
-
7021528012736
-
20113144
BU 0.6/1kV 4G 16mm² P17
BLACK
-
7021528012750
-
801279
BU 0.6/1kV 3X 25mm² P17
BLACK
-
7021528012798
-
801280
BU 0.6/1kV 3G 25mm² P17
BLACK
-
7021528012804
-
801286
BU 0,6/1KV 3X 35 mm² P17
BLACK
-
7021528012866
-
801200
801201
20110766
20121092
20110767
801205
20121093
20109454
20132893
20109455
20112689
801254
2019457
20109458
20109459
20109460
Subject to change without prior notice
Page 76 of 212
New Part
number
Old Part
number
20109461
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
BU 0.6/1kV 4G 35mm² P17
BLACK
-
7021528012897
-
801292
BU 0,6/1KV 3X 50 mm² P17
BLACK
-
7021528012927
-
801298
BU 0,6/1KV 3X 150 mm² P17
BLACK
-
702152801298
-
BU 0.6/1kV 4G 150mm² P17
BLACK
-
7021528013078
-
20109462
Electrical values power cables
Number of
elements
Cross
section
core, mm²
Max. conductor
Max. conductor
Reactance at
Reactance at
resistance at 20°C, resistance at 90°C, 50Hz, Ohm/km 60Hz, Ohm/km
Ohm/km
Ohm/km
Current rating IEC
Short circuit
60092-352 Table rating 1 second,
B.4, Ampere
Ampere
1
1
1
1
1
1
1
1
1
1
1
10
16
25
35
50
70
95
120
150
185
240
1.84
1.16
0.734
0.529
0.391
0.27
0.195
0.154
0.126
0.1
0.0762
2.35
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.128
0.107
0.1
0.096
0.093
0.091
0.087
0.086
0.084
0.084
0.083
0.082
0.128
0.12
0.115
0.111
0.11
0.105
0.103
0.1
0.1
0.099
0.098
72
96
127
157
196
242
293
339
389
444
522
1400
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
2
3
7
19
1.5
1.5
1.5
1.5
12.2
12.2
12.2
12.2
15.6
15.6
15.6
15.6
0.11
0.11
0.11
0.11
0.138
0.138
0.138
0.138
20
16
12
8.5
210
210
210
210
3G
7G
1.5
1.5
12.2
12.2
15.6
15.6
0.11
0.11
0.138
0.138
20
12.5
210
210
2
3
7
12
19
2.5
2.5
2.5
2.5
2.5
7.56
7.56
7.56
7.56
7.56
9.64
9.64
9.64
15.6
15.6
0.103
0.103
0.103
0.103
0.103
0.129
0.129
0.129
0.129
0.129
26
21
15.5
13
11
350
350
350
350
350
3G
4G
5G
2.5
2.5
2.5
7.56
7.56
7.56
9.64
9.64
9.64
0.103
0.103
0.103
0.129
0.129
0.129
26
21
21
350
350
350
3
4
4.7
5.99
0.096
0.120
28
560
3G
4G
4
4
4.7
4.7
9.64
9.64
0.096
0.096
0.120
0.120
34
28
560
560
2
3
6
6
3.11
3.11
3.97
3.97
0.09
0.09
0.112
0.112
44
36
840
840
4G
5G
6
6
3.11
3.11
3.97
3.97
0.09
0.09
0.112
0.112
36
36
840
840
2
3
10
10
1.84
1.84
3.97
2.35
0.084
0.084
0.105
0.105
61
50
1400
1400
4G
10
1.84
2.35
0.084
0.105
50
1400
3
16
1.16
1.48
0.08
0.099
67
2240
4G
16
1.16
1.48
0.08
0.099
67
2240
3
25
0.734
0.936
0.079
0.098
89
3500
3G
25
0.734
0.936
0.079
0.098
108
3500
3
35
0.529
0.675
0.076
0.094
110
4900
Subject to change without prior notice
Page 77 of 212
Number of
elements
4G
Cross
Max. conductor
Max. conductor
Reactance at
Reactance at Current rating IEC
Short circuit
section
resistance at 20°C, resistance at 90°C, 50Hz, Ohm/km 60Hz, Ohm/km 60092-352 Table rating 1 second,
core, mm²
Ohm/km
Ohm/km
B.4, Ampere
Ampere
35
0.529
0.675
0.076
0.094
110
4900
3
50
0.391
0.499
0.076
0.093
137
7000
3
150
0.126
0.161
0.072
0.088
272
21000
4G
150
0.126
0.161
0.072
0.088
272
21000
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 78 of 212
Halogen-free, unarmoured, mud resistant power cable, RU 0,6/1(1,2)kV, P18
Flame retardant halogen-free power cable.
Mud resistant
RU 0,6/1(1,2)kV
EPR/EVA
NEK TS 606 CodeP18
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
Fixed installation for power,control and lighting in
both EX- and safe areas, general purposes. For
installation in areas exposed to MUD and
drilling/cleaning fluids. Meets the OIL & MUD
resistance requirement in NEK TS 606:2009.
These cables are double-insulated and Single core
cables are used as battery cables.
IEC 60092-353
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Armour/screen
Outer sheath
R
U
Marking text
Manufacturing unit
Outer sheath
colour
Subject to change without prior notice
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
No inner covering. (Additional tapes may be applied)
No armour.
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2
(IEC 60092-360)
E.g. "meter" "year" DRAKA 01 RU 0,6/1KV P18 3 x 2,5 mm2 IEC 60332-3-22
DRAKA 01 = Draka Norsk Kabel,
Black
Page 79 of 212
Core identification power cables
Single core – Black
Two cores - Blue – Brown
Three cores - Brown - Black – Grey
Four cores - Blue - Brown - Black – Grey
Five cores - Blue - Brown - Black - Grey – Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue – Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60445 Ed 5.0 2010-08
Range and dimensions
Number of
elements
Cross section Conductor
core, mm²
Diameter, mm
Insulation
Thickness, mm
Thickness Outer
Sheath, mm
Diameter outer
sheath, mm
Weight of Cable
Approx. (Kg/Km)
Copper content
Approx. (kg/km)
1
1
1
1
1
1
1
1
1
25
50
70
95
120
150
185
240
300
6.45
9.0
10.9
12.60
14.20
15.90
17.70
20.15
22.60
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.1
1.2
1.3
1.4
1.4
1.5
1.6
1.7
1.8
11.5 ± 0.8
14.5 ± 0.8
16.5 ± 0.8
19 ± 0.8
20.5 ± 1
23 ± 1
25.5 ± 1
28.5 ± 1
31.5 ± 1.5
340
610
820
1110
1370
1710
2090
2680
3370
231
434
632
847
1082
1357
1664
2165
2757
2
3
4
5
7
12
19
24
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.2
1.2
1.4
1.5
1.6
9.5 ± 0.5
10 ± 0.8
11 ± 0.8
12 ± 0.8
12.5 ± 0.8
16.5 ± 0.8
19.5 ± 0.8
25 ± 1
135
160
190
240
280
460
680
890
28
42
56
70
98
168
266
335
3G
4G
5G
7G
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.0
1.0
1.0
1.0
1.1
1.1
1.2
1.2
10 ± 0.8
11 ± 0.8
12 ± 0.8
12.5 ± 0.8
160
190
240
280
42
56
70
98
2
3
4
5
7
2.5
2.5
2.5
2.5
2.5
2.0
2.0
2.0
2.0
2.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.2
1.2
1.3
10.5 ± 0.8
11 ± 0.8
12 ± 0.8
13.5 ± 0.8
14 ± 0.8
170
205
250
320
390
46
69
92
115
161
3G
4G
5G
2.5
2.5
2.5
2.0
2.0
2.0
1.0
1.0
1.0
1.1
1.2
1.2
11 ± 0.8
12 ± 0.8
13.5 ± 0.8
205
255
320
69
92
115
2
3
4
4
4
4
2.55
2.55
2.55
1.0
1.0
1.0
1.1
1.2
1.2
11.5 ± 0.8
12 ± 0.8
13.5 ± 0.8
220
275
340
74
110
147
3G
4G
5G
4
4
4
2.55
2.55
2.55
1.0
1.0
1.0
1.2
1.2
1.3
12 ± 0.8
13.5 ± 0.8
15 ± 0.8
275
340
410
110
147
184
2
6
3.15
1.0
1.2
12.5 ± 0.8
290
110
3
4
6
6
3.15
3.15
1.0
1.0
1.2
1.3
13.5 ± 0.8
15 ± 0.8
360
450
164
219
3G
4G
5G
6
6
6
3.15
3.15
3.15
1.0
1.0
1.0
1.2
1.3
1.3
13.5 ± 0.8
15 ± 0.8
16.5 ± 0.8
360
450
550
164
219
273
2
3
10
10
4.05
4.05
1.0
1.0
1.2
1.3
14.5 ± 0.8
15.5 ± 0.8
410
530
182
272
Subject to change without prior notice
Page 80 of 212
Number of
elements
4G
5G
Cross section
core, mm²
10
10
Conductor
Diameter, mm
4.05
4.05
Insulation
Thickness, mm
1.0
1.0
Thickness Outer
Sheath, mm
1.3
1.4
Diameter outer
sheath, mm
17.5 ± 0.8
19 ± 0.8
Weight of Cable
Approx. (Kg/Km)
660
820
Copper content
Approx. (kg/km)
363
453
2
3
4
16
16
16
5.15
5.15
5.15
1.0
1.0
1.0
1.3
1.4
1.4
17 ± 0.8
18.5 ± 0.8
20 ± 1
600
780
950
292
438
585
3G
4G
5G
16
16
16
5.15
5.15
5.15
1.0
1.0
1.0
1.4
1.4
1.5
18.5 ± 0.8
20 ± 1
22.5 ± 1
780
980
1200
438
584
730
2
3
4
25
25
25
6.45
6.45
6.45
1.2
1.2
1.2
1.4
1.5
1.6
20.5 ± 1
22.5 ± 1
24.5 ± 1
900
1170
1420
463
694
924
4G
25
6.45
1.2
1.6
25 ± 1
1500
925
2
3
35
35
7.65
7.65
1.2
1.2
1.5
1.6
23 ± 1
25 ± 1
1150
1520
629
943
4G
5G
35
35
7.65
7.65
1.2
1.2
1.7
1.8
28 ± 1
31 ± 1.5
1950
2370
1257
1571
3
50
9.0
1.4
1.7
29.5 ± 1
2090
1306
5G
50
9.0
1.4
2
36.5 ± 1.5
3310
2177
3
70
10.85
1.4
1.9
34 ± 1.5
2900
1900
5G
70
10.85
1.4
2.1
42 ± 2
4550
3167
Ordering information
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
831701
831703
831704
831705
831706
831707
831708
831709
831710
RU 0.6/1kV 1X 25mm² P18
RU 0.6/1kV 1X 50mm² P18
RU 0,6/1KV 1X 70 MM2 P18
RU 0.6/1kV 1X 95mm² P18
RU 0.6/1kV 1X 120mm² P18
RU 0.6/1kV 1X 150mm² P18
RU 0.6/1kV 1X 185mm² P18
RU 0.6/1kV 1X 240mm² P18
RU 0.6/1kV 1X 300mm² P18
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528317015
7021528317039
7021528317046
7021528317053
7021528317060
7021528317077
7021528317084
7021528317091
7021528317107
1061403
1061407
-
831715
831724
831725
831726
831728
831729
RU 0.6/1kV 2X 1.5mm² P18
RU 0.6/1kV 3X 1.5mm² P18
RU 0.6/1kV 4X 1.5mm² P18
RU 0.6/1kV 5X 1.5mm² P18
RU 0.6/1kV 7X 1.5mm² P18
RU 0.6/1kV 12X 1.5mm² P18
RU 0.6/1kV 19X 1.5mm² P18
RU 0,6/1KV 24X 1,5 MM2 P18
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528317152
7021528317183
7021528317213
7021528317244
7021528317251
7021528317268
7021528317282
7021528317299
-
831719
831720
831723
RU 0.6/1kV 3G 1.5mm² P18
RU 0.6/1kV 4G 1.5mm² P18
RU 0.6/1kV 5G 1.5mm² P18
RU 0.6/1kV 7G 1.5mm² P18
BLACK
BLACK
BLACK
BLACK
-
7021528317169
7021528317190
7021528317206
7021528317237
-
831739
RU 0.6/1kV 2X 2.5mm² P18
RU 0.6/1kV 3X 2.5mm² P18
RU 0,6/1KV 4X 2,5 MM2 P18
BLACK
BLACK
BLACK
-
7021528317336
7021528317367
7021528317398
-
831741
831743
RU 0.6/1kV 5X 2.5mm² P18
RU 0.6/1kV 7X 2.5mm² P18
BLACK
BLACK
-
7021528317411
7021528317435
-
831740
RU 0.6/1kV 3G 2.5mm² P18
RU 0.6/1kV 4G 2.5mm² P18
RU 0.6/1kV 5G 2.5mm² P18
BLACK
BLACK
BLACK
-
7021528317343
7021528317374
7021528317404
1061434
1061437
-
20115552
20130984
20109463
831733
20115556
20109464
20128690
Subject to change without prior notice
Page 81 of 212
New Part
number
Old Part
number
831751
831753
831755
RU 0.6/1kV 2X 4mm² P18
RU 0.6/1kV 3X 4mm² P18
RU 0,6/1KV 4X 4 MM2 P18
BLACK
BLACK
BLACK
-
7021528317510
7021528317534
7021528317558
-
831754
831756
RU 0.6/1kV 3G 4mm² P18
RU 0.6/1kV 4G 4mm² P18
RU 0,6/1KV 5G 4mm² P18
BLACK
BLACK
BLACK
-
7021528317527
7021528317541
7021528317565
-
831759
831761
831762
RU 0,6/1KV 2X 6 MM2 P18
RU 0.6/1kV 3X 6mm² P18
RU 0.6/1kV 4X 6mm² P18
BLACK
BLACK
BLACK
-
7021528317596
7021528317619
7021528317626
-
831764
831763
RU 0.6/1kV 3G 6mm² P18
RU 0.6/1kV 4G 6mm² P18
RU 0.6/1kV 5G 6mm² P18
BLACK
BLACK
BLACK
-
7021528317602
7021528317640
7021528317633
1061461
-
831766
831767
RU 0,6/1KV 2X 10 MM2 P18
RU 0.6/1kV 3X 10mm² P18
BLACK
BLACK
-
7021528317664
7021528317671
-
831769
831770
RU 0.6/1kV 4G 10mm² P18
RU 0.6/1kV 5G 10mm² P18
BLACK
BLACK
-
7021528317695
7021528317701
-
831772
831773
831774
RU 0.6/1kV 2X 16mm² P18
RU 0.6/1kV 3X 16mm² P18
RU 0,6/1KV 4X 16 MM2 P18
BLACK
BLACK
BLACK
-
7021528317725
7021528317732
7021528317749
-
831775
831777
RU 0.6/1kV 3G 16mm² P18
RU 0.6/1kV 4G 16mm² P18
RU 0.6/1kV 5G 16mm² P18
BLACK
BLACK
BLACK
-
7021528317756
7021528317763
7021528317770
-
831779
831780
831781
RU 0.6/1kV 2X 25mm² P18
RU 0.6/1kV 3X 25mm² P18
RU 0,6/1KV 4X 25 MM2 P18
BLACK
BLACK
BLACK
-
7021528317794
7021528317800
7021528317817
-
831782
RU 0.6/1kV 4G 25mm² P18
BLACK
-
7021528317824
-
831785
831786
RU 0,6/1KV 2X 35 MM2 P18
RU 0.6/1kV 3X 35mm² P18
BLACK
BLACK
-
7021528317855
7021528317862
-
831788
831789
RU 0.6/1kV 4G 35mm² P18
RU 0.6/1kV 5G 35mm² P18
BLACK
BLACK
-
7021528317886
7021528317893
-
831792
RU 0.6/1kV 3X 50mm² P18
BLACK
-
7021528317923
-
831796
RU 0.6/1kV 5G 50mm² P18
BLACK
-
7021528317961
-
831798
RU 0.6/1kV 3X 70mm² P18
BLACK
-
7021528317985
-
831799
RU 0.6/1kV 5G 70mm² P18
BLACK
-
7021528317992
-
20109465
20109466
20109467
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
Electrical values power cables
Number of
elements
Cross
section
core, mm²
Max. conductor
Max. conductor
Reactance at
Reactance at
resistance at 20°C, resistance at 90°C, 50Hz, Ohm/km 60Hz, Ohm/km
Ohm/km
Ohm/km
Current rating IEC
Short circuit
60092-352 Table rating 1 second,
B.4, Ampere
Ampere
1
1
1
1
1
1
1
1
1
25
50
70
95
120
150
185
240
300
0.734
0.391
0.27
0.195
0.154
0.126
0.1
0.0762
0.0607
0.499
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
0.094
0.09
0.085
0.085
0.083
0.082
0.082
0.081
0.08
0.113
0.108
0.102
0.102
0.1
0.099
0.098
0.098
0.096
127
196
242
293
339
389
444
522
601
3500
7000
9800
13300
16800
21000
25900
33600
42000
2
3
4
5
7
1.5
1.5
1.5
1.5
1.5
12.2
12.2
12.2
12.2
12.2
15.6
15.6
15.6
15.6
15.6
0.11
0.11
0.11
0.11
0.11
0.132
0.132
0.132
0.132
0.132
20
16
16
13.5
12
210
210
210
210
210
Subject to change without prior notice
Page 82 of 212
Number of
elements
12
19
24
Cross
Max. conductor
section
resistance at 20°C,
core, mm²
Ohm/km
1.5
12.2
1.5
12.2
1.5
12.2
Max. conductor
resistance at 90°C,
Ohm/km
15.6
15.6
15.6
0.132
0.132
0.132
Current rating IEC
60092-352 Table
B.4, Ampere
10
8.5
8
Short circuit
rating 1 second,
Ampere
210
210
210
0.11
0.11
0.11
3G
4G
5G
7G
1.5
1.5
1.5
1.5
12.2
12.2
12.2
12.2
15.6
15.6
15.6
15.6
0.11
0.11
0.11
0.11
0.132
0.132
0.132
0.132
20
16
16
12.5
210
210
210
210
2
3
4
5
7
2.5
2.5
2.5
2.5
2.5
7.56
7.56
7.56
7.56
7.56
9.64
9.64
9.64
9.64
9.64
0.103
0.103
0.103
0.103
0.103
0.123
0.123
0.123
0.123
0.123
26
21
21
17.5
15.5
350
350
350
350
350
3G
4G
5G
2.5
2.5
2.5
7.56
7.56
7.56
9.64
9.64
9.64
0.103
0.103
0.103
0.123
0.123
0.123
26
21
21
350
350
350
2
3
4
4
4
4
4.7
4.7
4.7
5.99
5.99
5.99
0.096
0.096
0.096
0.115
0.115
0.115
34
28
28
560
560
560
3G
4G
5G
4
4
4
4.7
4.7
4.7
5.99
5.99
5.99
0.096
0.096
0.096
0.115
0.115
0.115
34
28
28
560
560
560
2
3
4
6
6
6
3.11
3.11
3.11
3.97
3.97
3.97
0.09
0.09
0.09
0.108
0.108
0.108
44
36
36
840
840
840
3G
4G
5G
6
6
6
3.11
3.11
3.11
3.97
3.97
3.97
0.09
0.09
0.09
0.108
0.108
0.108
44
36
36
840
840
840
2
3
10
10
1.84
1.84
2.35
2.35
0.084
0.084
0.101
0.101
61
50
1400
1400
4G
5G
10
10
1.84
1.84
2.35
2.35
0.084
0.084
0.101
0.101
50
50
1400
1400
2
3
4
16
16
16
1.16
1.16
1.16
1.48
1.48
1.48
0.08
0.08
0.08
0.096
0.096
0.096
80
67
67
2240
2240
2240
3G
4G
5G
16
16
16
1.16
1.16
1.16
1.48
1.48
1.48
0.08
0.08
0.08
0.096
0.096
0.096
80
67
67
2240
2240
2240
2
3
4
25
25
25
0.734
0.734
0.734
0.936
0.936
0.936
0.079
0.079
0.079
0.095
0.095
0.095
108
89
89
3500
3500
3500
4G
25
0.734
0.936
0.079
0.095
89
3500
2
3
35
35
0.529
0.529
0.675
0.675
0.076
0.076
0.092
0.092
133
110
4900
4900
4G
5G
35
35
0.529
0.529
0.675
0.675
0.076
0.076
0.092
0.092
110
110
4900
4900
3
50
0.391
0.499
0.076
0.092
137
7000
5G
50
0.391
0.499
0.076
0.092
137
7000
3
70
0.27
0.344
0.074
0.088
169
9800
5G
70
0.27
0.344
0.074
0.088
169
9800
Subject to change without prior notice
Reactance at
Reactance at
50Hz, Ohm/km 60Hz, Ohm/km
Page 83 of 212
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 84 of 212
Cable for Variable Frequency Drives (VFD’s), RFOU-VFD 0,6/1(1,8/3)kV with flexible
conductors class 5 and separate earth cores
Flame retardant cables
RFOU-VFD
0,6/1 (1,8/3)kV
Power cable for variable frequency drives
Class 5 conductors
Halogen free and Mud resistant
Maximum operating
conductor temperature
: 90°C
Operating voltage
: 0,6/1(1,2)kV
Application
Standards applied
Special cable for Variable Frequency Drives /
Azimuth motors up to 1kV.
Suitable for voltage peaks up to 3600V.
Armoured cable for fixed installations in ships and
offshore units. Can be installed and operated both
indoors and outdoors. Oil and MUD resistant to
NEK606.
IEC 60092-353
IEC 60228 class 5
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
CONSTRUCTION
CODE LETTER
Conductor
Insulation
Tinned, annealed, flexible copper, IEC 60228 class 5.
R
EP-rubber, IEC 60092-360 (EPR)
Bedding
F
3 insulated phase-conductors are laid up with 3 insulated earth
conductors.
Flame retardant halogen-free thermoset compound
Armour
O
Lay up
Outer sheath
U
Cu/PETP-tape
Tinned copper wire braid.
PETP-tape
Shield coverage is 100%
Flame retardant halogen-free thermoset compound, SHF2 (IEC
60092-360).
Marking
E.g; ”meter” ”DRAKA 01 RFOU – VFD 0,6/1(1,8/3)kV 3  95 + 3 x
16 mm² IEC 60332-3-22
Colour
Black or Yellow
Subject to change without prior notice
Page 85 of 212
Core identification:
The three main power cores:
All three Earth cores:
Brown – Black – Grey
Yellow/green
RANGE AND DIMENSIONS
RFOU-VFD 0,6/1(1,8/3) kV
No. of
cores and
cond.
area
mm²
Thickness
of
bedding
approx.
mm
Cond.
diam.
appr.
Insulation
thickness
mmØ
mm
Diameter
over
bedding
mmØ
Armour/
screen
wire
diameter
mmØ
Thickness
of outer
sheath,
nominal
mm
Diameter
overall
Weight
of cable
mmØ
kg/km
Copper
content
Approx.
(kg/km)
3x 10 +
3x 4
4.3
2.7
2.8
1.0
1.5
24.5 ± 1,0
0.30
1.6
29,0 ± 1,0
1470
525
3x 25 +
3x 6
7,2
3,3
2,2
1.0
1,6
28,5±1,0
0,30
1,8
33,5±1,5
2180
1045
3x 35 +
3x 6
8,45
3,3
2,2
1,0
1.6
31.5 ± 1.5
0.30
1.9
36.5 ± 1.5
2540
1320
3x 50 +
3x 10
10,65
4,3
2,4
1,0
1,6
36,0±1,5
0,30
2,0
41,5±2,0
3500
1860
3x 95 +
3x 16
14,3
5.9
2,4
1,0
1,6
45,0±2,0
0,40
2,3
51,0±2,5
5690
3400
3x 95 +
3x 25
14,3
7,2
2,4
1,2
1,6
45.5±2,0
0,4
2,3
52±2,0
6000
3650
3x 120 +
3x 25
16,6
7,2
2,4
1,2
1,8
50,0±2,5
0,40
2,5
57,0±2,5
7130
4380
3x 150 +
3x 16
18,1
5,9
2,4
1,0
1,8
53,5±2,5
0,40
2,6
60,5±3,0
8200
5105
3x 150 +
3x 25
18,1
2,4
1,0
1,8
53,5 ± 2,5
0,40
2,6
60,5 ± 3,0
8390
5345
3x 150 +
3x 35
18,1
2,4
1,2
1,8
53,5 ± 2,5
0,40
2,6
60,5 ± 3,0
8560
5590
3x 185 +
3x 16
19,9
5,9
2,4
1,0
1,8
57,5±2,5
0,40
2,7
65,0±3,0
9550
6060
Tba = to be agreed in case of an order
Ordering information
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
RFOU-VFD 1kV(3kV) 3x 10 mm² + 3x 4 mm²
886833 RFOU-VFD 1kV(3kV) 3x 10 mm² + 3x 4 mm²
YELLOW
BLACK
-
-7021528868333
-
886829 RFOU-VFD 1kV(3kV) 3x 25 mm² + 3x 6 mm²
RFOU-VFD 1kV(3kV) 3x 25 mm² + 3x 6 mm²
YELLOW
BLACK
-
7021528868296
-
-
RFOU-VFD 1kV(3kV) 3x 35 mm² + 3x 6 mm²
RFOU-VFD 1kV(3kV) 3x 35 mm² + 3x 6 mm²
BLACK
YELLOW
-
-
-
20109486
886828 RFOU-VFD 1kV(3kV) 3x 50 mm² + 3x 10 mm²
RFOU-VFD 1kV(3kV) 3x 50 mm² + 3x 10 mm²
YELLOW
BLACK
-
7021528868589
7021528868319
-
20109487
886360 RFOU-VFD 1kV(3kV) 3x 95 mm² + 3x 16 mm²
RFOU-VFD 1kV(3kV) 3x 95 mm² + 3x 16 mm²
YELLOW
BLACK
-
7021528863604
7021528868326
-
RFOU-VFD 1kV(3kV) 3x 95 mm² + 3x 25 mm²
RFOU-VFD 1kV(3kV) 3x 95 mm² + 3x 25 mm²
YELLOW
BLACK
-
-
-
886756 RFOU-VFD 1kV(3kV) 3x 120 mm² + 3x 25 mm²
887077 RFOU-VFD 1kV(3kV) 3x 120 mm² + 3x 25 mm²
YELLOW
BLACK
-
7021528867565
7021528870770
-
886421 RFOU-VFD 1kV(3kV) 3x 150 mm² + 3x 16 mm²
RFOU-VFD 1kV(3kV) 3x 150 mm² + 3x 16 mm²
YELLOW
BLACK
-
7021528864212
-
-
Subject to change without prior notice
Page 86 of 212
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
RFOU-VFD 1kV(3kV) 3x 150 mm² + 3x 25 mm²
887078 RFOU-VFD 1kV(3kV) 3x 150 mm² + 3x 25 mm²
YELLOW
BLACK
-
7021528870787
-
886793 RFOU-VFD 1kV(3kV) 3x 150 mm² + 3x 35 mm²
RFOU-VFD 1kV(3kV) 3x 150 mm² + 3x 35 mm²
YELLOW
BLACK
-
7021528867930
-
-
887207 RFOU-VFD 1kV(3kV) 3x 185 mm² + 3x 16 mm²
RFOU-VFD 1kV(3kV) 3x 185 mm² + 3x 16 mm²
YELLOW
BLACK
-
7021528872071
-
-
Electrical values power cables
No. of
cores and
cond.
area
mm²
Resistance
at 20°C
Resistance
at 90°C
Reactance
at 50Hz
Current
rating at
45°C
ohm/km
ohm/km
Ohm/km
Ampere
Short
curcuit
rating
1 sec.
Ampere
3x 10 +
3x 4
1,95
5,09
2,49
6,49
0,083
50
1400
3x 25 +
3x 6
0,795
3,39
1,014
4,323
0,089
89
3500
3x 35 +
3x 6
0,565
3,39
0,668
4,323
0,086
110
4900
3x 50 +
3x 10
0,393
1,95
0,501
2,486
0,081
137
7000
3x 95 +
3x 16
0,210
1,24
0,268
1,58
0,077
205
13300
3x 95 +
3x 25
0,210
0,795
0,268
1,014
0,077
205
13300
3x 120 +
3x 25
0,164
0,795
0,209
1,014
0,075
237
16800
3x 150 +
3x 16
0,132
1,24
0,1683
1,58
0,074
272
21000
3x 150 +
3x 25
0,132
0,795
0,1683
1,013
0,074
272
21000
3x 150 +
3x 35
0,132
0,565
0,1683
0,7204
0,074
272
21000
3x 185 +
3x 16
0,108
1,24
0,1683
1,58
0,073
311
25900
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius
Fixed Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 87 of 212
Cable for Variable Frequency Drives (VFD’s), RFOU-VFD 0,6/1(1,8/3)kV with stranded
conductors class 2 and tinned copper wire braid as earth
Flame retardant cables
RFOU-VFD
0,6/1kV(1,8/3kV)
EPR/EPR/TCWB/EVA
Halogen-free, Mud resistant
Maximum operating
Conductor temperature
Operating voltage
Application
Standards applied
Special cable for Variable Frequency Drives /
Azimuth motors up to 1kV.
Suitable for voltage peaks up to 3600V.
Armoured cable for fixed installations in ships and
offshore units. Can be installed and operated both
indoors and outdoors. Oil and MUD resistant to
NEK606.
IEC 60092-353
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
: 90OC
: 0,6/1kV (3 kV)
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
CONSTRUCTION
CODE LETTER
Conductor
Circular, tinned, stranded copper. IEC 60228 Class 2 (1)
Insulation
R
EP-rubber (2)
Bedding
F
Flame retardant and halogen-free thermoset compound. (3)
Armour
O
Outer sheath
U
Marking
Colour
Cu/PETP-tape. (4)
Tinned copper wire braid. (5) Shield coverage is 100%
PETP-tape. (6)
Flame retardant, halogen-free and mud resistant thermoset
compound, SHF2.(7)
E.g; “meter” “year” DRAKA 01 RFOU-VFD 0,6/1kV (1,8/3) kV 3x
95/50 mm² IEC 60332-3-22
Yellow or Black
Core identification:
Three cores:
Brown – Black - Grey
Subject to change without prior notice
Page 88 of 212
RANGE AND DIMENSIONS: RFOU-VFD 0,6/1kV (1,8/3)kV
No. of
cores and
cond. area
(mm²)
Cond.
diam. appr.
(mmØ)
Insulation
thickness
Diameter
bedding
(mm)
Thickness
of inner
covering,
mm
(mmØ)
3x 2.5/10
3x 4/10
3x 6/10
3x 10/10
3x 16/16
3x 25/16
3x 50/25
3x 70/35
3x 95/50
3x 120/60
3x 150/70
2.0
2.55
3,15
4,05
5,15
6,75
9,10
10.85
12,60
14.20
15.90
2.2
2.2
2.2
2.2
2,2
2.2
2.2
2.2
2,4
2.4
2.4
1.1
1.1
1.2
1.2
1.6
1.6
1.7
1.6
2,0
2.0
1.4
16.5 ± 0.8
17.5 ± 0.8
19 ± 0.8
21 ± 1
24 ± 1
28 ± 1
33 ± 1.5
36.5 ± 1.5
42 ± 2,0
45.5 ± 2
48 ± 2,0
3x 185/95
17.7
2.4
2.0
53 ± 2.5
3x 240/120
20.15
2.4
1.8
58.5 ± 2.5
Diameter
of armour
/shield wire
(mmØ)
Thickness
outer
sheath,
mm
Diameter
outer
sheath
(mmØ)
Weight of
cable
approx
(kg/km)
Copper
content
Approx.
(kg/km)
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.50
0.60
0.60
2 layer
0.40
2 layer
0.50
2 layer
0.60
1.5
1.5
1.6
1.6
1.7
1.8
2
2.2
2,3
2.5
2,7
20.5 ± 1
21.5 ± 1
23.5 ± 1
25 ± 1
29 ± 1
33 ± 1.5
38.5 ± 1.5
43 ± 2
49 ± 2
53 ± 2.5
56.5 ± 2,5
690
780
940
1130
1560
2090
3110
4160
5420
6590
7800
202
243
314
422
638
935
1617
2385
3166
3975
5015
2.8
63 ± 3
9660
6288
3
68.5 ± 3
11970
8050
Ordering information
New Part
number
Old Part
number
886852
886854
886972
886973
20114764
886971
886970
20109484
Description
Sheath Colour
RFOU-VFD 1kV(3kV) 3x 2.5/10 mm²
RFOU-VFD 1kV(3kV) 3x 4/10 mm²
RFOU-VFD 1kV(3kV) 3x 6/10 mm²
RFOU-VFD 1kV(3kV) 3x 10/10 mm²
RFOU-VFD 1kV(3kV) 3x 16/16 mm²
RFOU-VFD 1kV(3kV) 3x 16/16 mm²
RFOU-VFD 1kV(3kV) 3x 25/16 mm²
RFOU-VFD 1kV(3kV) 3x 50/25 mm²
RFOU-VFD 1kV(3kV) 3x 70/35 mm²
RFOU-VFD 1kV(3kV) 3x 95/50 mm²
RFOU-VFD 1kV(3kV) 3x 120/60 mm²
RFOU-VFD 1kV(3kV) 3x 150/70 mm²
RFOU-VFD 1kV(3kV) 3x 185/95 mm²
RFOU-VFD 1kV(3kV) 3x 240/120 mm²
BLACK
BLACK
BLACK
BLACK
YELLOW
BLACK
YELLOW
YELLOW
BLACK
BLACK
YELLOW
BLACK
YELLOW
BLACK
Stock item
-
EAN No. DNK
7021528868524
7021528868548
7021528869729
7021528869736
7021528868890
7021528869712
7021528869705
-
Electrical characteristics
No. of
cores and
cond. area
(mm²)
Resistance at
20°C
3x 2.5/10
3x 4/10
3x 6/10
3x 10/10
3x 16/16
3x 25/16
3x 50/25
3x 70/35
3x 95/50
3x 120/60
3x 150/70
3x 185/95
3x 240/120
7.56
4.7
3.11
1.84
1,16
0.734
0.391
0.270
0,195
0.154
0.126
0.100
0.0762
(ohm/km)
Resistance
at 90°C
Reactance
at 50Hz
(ohm/km)
9.64
5.99
3.97
2.35
1.48
0.936
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
Subject to change without prior notice
(ohm/km)
Current
rating at
45°C
(ampere)
Short
curcuit
rating,
1 sec
(ampere)
0.131
0.122
0.114
0.105
0.098
0.091
0.084
0.081
0.080
0.078
0.076
0.074
0.073
21
28
36
50
67
89
137
169
205
237
273
311
366
350
560
840
1400
2240
3500
7000
9800
13300
16800
21000
25900
33600
Page 89 of 212
EL No.
-
Correction factors for different ambient temperatures:
Ambient temp. °C
Rating factors
25
30
35
40
45
50
55
60
65
70
75
1,22
1,17
1,12
1,06
1,00
0,94
0,87
0,79
0,71
0,61
0,5
Installation recommendations:
In accordance with IEC 60092-352
Minimum bending radius
During installation
8 x cable diameter
Maximum pulling tension
Minium installation
temperature
Fixed installed
6 x cable diameter
Subject to change without prior notice
50N x total
Cross section of
conductors
- 20 °C
Page 90 of 212
Fire resistant optical fibre cable, QFCI-I/O/RM-JM/-, F1
QFCI-I/O/RM-JM/Indoor and outdoor.
Fire resistant
Flame retardant halogen-free
Loose tube
NEK 606 Code F1
Optical cable for indoor and outdoor use in vital communication and
emergency systems that need to be operational during fire. The
cable has a patented design that ensures operation for more than 3
hours in fires up to 1000ºC. The cable is halogen free and flame
retardant to protect against secondary damage to electronic
equipment during and after fire. Outer sheath is made from black
UV-stabilized and weather resistant material and may be exposed
for shorter periods to fluids such as diesel and mineral oils. The
resistance to these fluids is according to IEC60811-2-1. The cable
is reinforced with a steel wire braiding. The fibres are protected in
jelly filled loose tubes stranded around a central strength member
to ensure optimum performance and long life. Each fibre and loose
tube is colour coded for easy identification during splicing and
termination. The outer sheath is marked to show fibre type and
cable type. The sheath colour is BLACK.
Fibres in mica wrapped
loose tube
Steel strength element
Wrapping
Inner sheath
Filler
Steel wire braiding
Outer sheath
Weight and dimensions
Number of
fibres
4
8
12
24
48
Number of
fibres in each
tube
2
4
4
4
8
Number of
tubes + fillers
2+4
2+4
3+3
6+0
6+0
Loose tube
diameter
(mm)
2.2
2.2
2.2
2.2
2.2
Outer
diameter
(mm)
13.5
13.5
13.5
13.5
13.5
Weight
Heat release
(kg/km)
260
260
260
260
260
(MJ/km)
1390
1381
1324
1138
1138
Other fibre counts are available on request.
Cable properties
Tensile strength (IEC 60794-1-2E1)
Max tensile load during installation
Max tensile load during operation
Crush (IEC 60794-1-2E3)
Impact (IEC 60794-1-2E4)
Torsion (IEC 60794-1-2E7)
Cable bending
Minimum bending diameter
Cable bend (IEC 60794-1-2E11)
Temperature window
Operation
Installation
Storage
Subject to change without prior notice
Chemical reistance
1500 N Mineral oils IRM 902 (IEC60811-2-1)
500 N
Diesel - IRM 903 (IEC60811-2-1)
3000 N/10cm Fire and smoke classifications
30J IEC 60331-25 (750C, 90 minutes)
1 turn/1m Upgraded IEC 60331-25 (1000C, 3 hours)
BP GS 112-2 Clause7.1
250 mm IEC 61034
<0.1dB/ 5 turn IEC 60332-3-22 (Cat. A)
IEC 60332-3-24 (Cat. C)
IEC 60754-1
-40C to +70C IEC 60754-2
-10C to +70C
-40C to +70C
- 7 days/23°C
- 4 hours/70°C
- 7 days/23°C
- 4 hours/70°C
<1.0 dB excess loss
<1.5 dB excess loss
Page 91 of 212
Ordering information
Part no
Number
of fibres
Cabe Type
Fiber type
Stock
Item
Fiber data
sheet
20110842
8
G8-9/125 QFCI-I/O/RM-JM/-
OS2 Single mode
-
C03e
20109401
12
G12-9/125 QFCI-I/O/RM-JM/-
OS2 Single mode
Yes
C03e
20109404
24
G24-9/125 QFCI-I/O/RM-JM/-
OS2 Single mode
Yes
C03e
20109399
48
G48-9/125 QFCI-I/O/RM-JM/-
OS2 Single mode
Yes
C03e
20109398
4
G4-50/125 QFCI-I/O/RM-JM/-
OM2 50/125 multi mode
-
C23
20109402
12
G12-50/125 QFCI-I/O/RM-JM/-
OM2 50/125 multi mode
-
C23
C23
20110759
24
G24-50/125 QFCI-I/O/RM-JM/-
OM2 50/125 multi mode
-
694169
48
G48-50/125 QFCI-I/O/RM-JM/-
OM2 50/125 multi mode
-
C23
20109417
4
G4-50/125OM3 QFCI-I/O/RM-JM/-
OM3 MaxCap-OM3
-
C31
C31
699875
12
G12-50/125OM3 QFCI-I/O/RM-JM/-
OM3 MaxCap-OM3
-
699872
24
G24-50/125OM3 QFCI-I/O/RM-JM/-
OM3 MaxCap-OM3
-
C31
20110843
48
G48-50/125OM3 QFCI-I/O/RM-JM/-
OM3 MaxCap-OM3
-
C31
20110462
4
G4-62.5/125 QFCI-I/O/RM-JM/-
OM1 62.5/125 multi mode
Yes
C02
C02
20110463
8
G8-62.5/125 QFCI-I/O/RM-JM/-
OM1 62.5/125 multi mode
Yes
20109403
12
G12-62.5/125 QFCI-I/O/RM-JM/-
OM1 62.5/125 multi mode
Yes
C02
C02
C02
20109405
24
G24-62.5/125 QFCI-I/O/RM-JM/-
OM1 62.5/125 multi mode
Yes
20109406
48
G48-62.5/125 QFCI-I/O/RM-JM/-
OM1 62.5/125 multi mode
-
Colour codes
Fibre
Colour
number
1
White
2
Red
3
Yellow
4
Green
5
Blue
6
Grey
7
Brown
8
Black
Tube
number
1
2
3
4
5
6
Colour
Red
Green
White
White
White
White
We reserve the right to alter this specification without notice.
Other fibre types and qualities are available on request.
Subject to change without prior notice
Page 92 of 212
Fire resistant optical fibre cable, QFCI-I/O/RM/C-JM/-, MUD PROTECTED (F5)
QFCI-I/O/RM/C-JM/Indoor and outdoor.
Fire resistant
Flame retardant halogen-free
Loose tube
NEK 606 Code (F5)
Optical cable for indoor and outdoor use in vital communication and
emergency systems that need to be operational during fire. The
cable has a patented design that ensures operation for more than 3
hours in fires up to 1000ºC. The cable is halogen free and flame
retardant to protect against secondary damage to electronic
equipment during and after fire. Outer sheath(1) is made from black
UV-stabilized and weather resistant material and may be exposed
for shorter periods to fluids such as diesel and mineral oils. The
resistance to these fluids is according to IEC60811-2-1. The cable
is reinforced with a steel wire braiding. The fibres are protected in
jelly filled loose tubes stranded around a central strength member
to ensure optimum performance and long life. Each fibre and loose
tube is colour coded for easy identification during splicing and
termination. The outer sheath is marked to show fibre type and
cable type.
An additional outer sheath is added for improved oil- and MUD
protection. The sheath colour is GREY.
Fibres in mica wrapped
loose tube
Steel strength element
Wrapping
Inner sheath
Filler
Steel wire braiding
Outer sheath (1)
Outer sheath (MUD)
Weight and dimensions
Number of
fibres
8
12
24
48
Number of
fibres in each
tube
4
4
4
8
Number of
tubes + fillers
2+4
3+3
6+0
6+0
Loose tube
diameter
(mm)
2.2
2.2
2.2
2.2
Outer
diameter
(mm)
15.5
15.5
15.5
15.5
Weight
(kg/km)
325
325
325
325
Heat release
(Estimated)
(MJ/km)
2000
2000
2000
2000
Other fibre counts are available on request.
Cable properties
Tensile strength (IEC 60794-1-2E1)
Max tensile load during installation
Max tensile load during operation
Crush (IEC 60794-1-2E3)
Impact (IEC 60794-1-2E4)
Torsion (IEC 60794-1-2E7)
Cable bending
Minimum bending diameter
Cable bend (IEC 60794-1-2E11)
Temperature window
Operation
Installation
Storage
Subject to change without prior notice
Chemical resistance
1500 N Mineral oils IRM 902 (IEC60811-2-1)
500 N Diesel - IRM 903 (IEC60811-2-1)
3000 N/10cm Fire and smoke classifications
30J IEC 60331-25 (750C, 90 minutes)
1 turn/1m Upgraded IEC 60331-25 (1000C, 3 hours)
BP GS 112-2 Clause7.1
250 mm IEC 61034
<0.1dB/ 5 turn IEC 60332-3-22 (Cat. A)
IEC 60332-3-24 (Cat. C)
IEC 60754-1
-40C to +70C
-10C to +70C
-40C to +70C
- 7 days/100°C
- 7 days/100°C
<1.0 dB excess loss
<1.5 dB excess loss
Page 93 of 212
Ordering information
Part no
20109485
Number Cabe Type
of
fibres
8
G8-9/125 QFCI-I/O/RM/C-JM/-
Fiber type
Stock
Item
Fiber data
sheet
OS2 Single mode
C03e
20109488
12
G12-9/125 QFCI-I/O/RM/C-JM/-
OS2 Single mode
C03e
20109483
24
G24-9/125 QFCI-I/O/RM/C-JM/-
OS2 Single mode
C03e
20116217
48
G48-9/125 QFCI-I/O/RM/C-JM/-
OS2 Single mode
C03e
20109490
8
G8-50/125 QFCI-I/O/RM/C-JM/-
OM2 50/125 multi mode
C23
20112243
12
G12-50/125 QFCI-I/O/RM/C-JM/-
OM2 50/125 multi mode
C23
20118902
24
G24-50/125 QFCI-I/O/RM/C-JM/-
OM2 50/125 multi mode
C23
48
G48-50/125 QFCI-I/O/RM/C-JM/-
OM2 50/125 multi mode
C23
12
G12-50/125OM3 QFCI-I/O/RM/C-JM/-
OM3 MaxCap-OM3
C31
24
G24-50/125OM3 QFCI-I/O/RM/C-JM/-
OM3 MaxCap-OM3
C31
48
G48-50/125OM3 QFCI-I/O/RM/C-JM/-
OM3 MaxCap-OM3
C31
4
G4-62.5/125 QFCI-I/O/RM/C-JM/-
OM1 62.5/125 multi mode
C02
20110579
8
G8-62.5/125 QFCI-I/O/RM/C-JM/-
OM1 62.5/125 multi mode
C02
20109481
12
G12-62.5/125 QFCI-I/O/RM/C-JM/-
OM1 62.5/125 multi mode
C02
20109482
24
G24-62.5/125 QFCI-I/O/RM/C-JM/-
OM1 62.5/125 multi mode
C02
20116216
48
G48-62.5/125 QFCI-I/O/RM/C-JM/-
OM1 62.5/125 multi mode
C02
20110577
Colour codes
Fibre
Colour
number
1
White
2
Red
3
Yellow
4
Green
5
Blue
6
Grey
7
Brown
8
Black
Tube
number
1
2
3
4
5
6
Colour
Red
Green
White
White
White
White
Standard colur on outer sheet is Grey
We reserve the right to alter this specification without notice.
Other fibre types and qualities are available on request.
Subject to change without prior notice
Page 94 of 212
Flame retardant optical fibre cable, AICI-I/O/RM-W, F6
AICI-I/O/RM-W
Indoor and outdoor
Flame retardant and halogen free
Steel wire braiding
Tight buffer
NEK 606 Code F6
Optical cable for industrial environments. The cable is suitable
for both indoor and outdoor installation. The outer sheath is
made from black UV-stabilized and weather resistant material
which is SHF1 classified, and may be exposed for shorter
periods to fluids such as diesel and mineral oils. The
resistance to these fluids is according to IEC60811-2-1. The
cable is reinforced with a steel wire braiding between the two
sheaths. Strength elements of glass yarn around the cable
core allow easy installation of long lengths. The 0.9 mm tight
buffer is easy to strip allowing fast and reliable splicing and
connector mounting. Each fibre is colour coded for easy
identification. The outer sheath is marked to show fibre type
and cable type. The outer sheath is BLACK.
Secondary coated fibre
Water swellable material
Glass yarn
Inner sheath
Steel wire braiding
Outer sheath
Weight and dimensions
Number of fibres
Secondary coating
Outer diameter
Weight
[mm]
0.9
0.9
0.9
0.9
[mm]
[kg/km]
4
8
12
24
8.2
9.4
10.3
12.0
90
125
145
185
Tensile strength*
[Inst./oper.]
[N]
700/250
800/350
1200/500
1700/750
Cable properties
*Tensile strength (IEC 60794-1-2E1)
Max tensile load during installation
Max tensile load during operation
Crush (IEC 60794-1-2E3)
Impact (IEC 60794-1-2E4)
Torsion (IEC 60794-1-2E7)
Cable bending
Minimum bending diameter
Cable bend (IEC 60794-1-2E11)
Flexibility (IEC 60794-1-2E8)
Temperature window
See above
See above
Operation
Installation
Storage
-40C to +70C
-10C to +70C
-40C to +70C
2000 N/10cm Water tightness* (IEC 60794-1-2F5B)
1 impacts, 25J Fire and smoke classifications
 1 turn/1m IEC 60332-1
IEC 60332-3-22 (Cat. A)
IEC 60332-3-24 (Cat. C)
15x outer diameter IEC 61034
<0.5 dB/  5 turn IEC 60754-1
1000 cycles IEC 60754-2
Chemical reistance
Mineral oils IRM 902 (IEC60811-2-1)
< 3 m/24 hours
- 7 days/23°C
- 4 hours/70°C
Diesel - IRM 903 (IEC60811-2-1)
- 7 days/23°C
- 4 hours/70°C
*) – Steel wire braiding is not watertight.
Subject to change without prior notice
Page 95 of 212
Ordering information
Part no
20109407
20109409
Number
of fibres
4
8
Cabe Type
G4-9/125 AICI-I/O RM-W
G8-9/125 AICI-I/O RM-W
Fiber type
Stock
Item
Fiber data
sheet
OS2 Single mode
-
C03e
OS2 Single mode
-
C03e
C03e
20109412
12
G12-9/125 AICI-I/O RM-W
OS2 Single mode
-
20117329
24
G24-9/125 AICI-I/O RM-W
OS2 Single mode
-
C03e
20122674
4
G4-50/125 AICI-I/O RM-W
OM2 50/125 multi mode
-
C34
695442
8
G8-50/125 AICI-I/O RM-W
OM2 50/125 multi mode
-
C34
695452
12
G12-50/125 AICI-I/O RM-W
OM2 50/125 multi mode
-
C34
C34
20110876
24
G24-50/125 AICI-I/O RM-W
OM2 50/125 multi mode
-
1019310
4
G4-50/125OM3BB AICI-I/O RM-W
OM3 MaxCap-BB-OM3
-
C31
C31
20109410
8
G8-50/125OM3BB AICI-I/O RM-W
OM3 MaxCap-BB-OM3
-
695453
12
G12-50/125OM3BB AICI-I/O RM-W
OM3 MaxCap-BB-OM3
-
C31
20117332
24
G24-50/125OM3BB AICI-I/O RM-W
OM3 MaxCap-BB-OM3
-
C31
20109408
4
G4-62.5/125 AICI-I/O RM-W
OM1 62.5/125 multi mode
Yes
C02
20109411
8
G8-62.5/125 AICI-I/O RM-W
OM1 62.5/125 multi mode
Yes
C02
OM1 62.5/125 multi mode
-
C02
OM1 62.5/125 multi mode
-
C02
20109413
20109414
12
24
G12-62.5/125 AICI-I/O RM-W
G24-62.5/125 AICI-I/O RM-W
OM4 and other fibre types on request.
Colour code
Fibre
Colour
no.
1
White
2
Red
3
Yellow
4
Green
5
Blue
6
Grey
7
Brown
8
Black
Fibre
no.
9
10
11
12
13
14
15
16
Colour
Violet
Turquise
Orange
Pink
White + marker
Red + marker
Yellow + marker
Green + marker
Fibre
no.
17
18
19
20
21
22
23
24
Colour
Blue + marker
Grey + marker
Brown + marker
Light Blue + marker
Violet + marker
Turquise + marker
Orange + marker
Pink + marker
Standard colour of outer sheath is black.
We reserve the right to alter this specification without notice.
Subject to change without prior notice
Page 96 of 212
Flame retardant optical fibre cable, AICI-I/O/RM/C-W, MUD PROTECTED
Armoured industrial cable
AICI-I/O/RM/C-W
Indoor and outdoor
Flame retardant and halogen free
Steel wire braiding
Tight buffer
MUD PROTECTED
Optical cable for industrial environments. The cable is suitable
for both indoor and outdoor installation. Continiuous
submergence in water is not recommended. Outer sheath (1)
is made from black UV-stabilized and weather resistant
material and may be exposed for shorter periods to fluids
such as diesel and mineral oils. The resistance to these fluids
is according to IEC60811-2-1. The cable is reinforced with a
steel wire braiding between the two sheaths. Strength
elements of glass yarn around the cable core allow easy
installation of long lengths. The 0.9 mm tight buffer is easy to
strip allowing fast and reliable splicing and connector
mounting. Each fibre is colour coded for easy identification.
The outer sheath is marked to show fibre type and cable type.
Secondary coated fibre
Water swellable material
Glass yarn
Inner sheath
Steel wire braiding
Outer sheath (1)
Outer sheath (MUD)
An additional outer sheath is added for improved oil- and
MUD protection. The outer sheath is DARK GREY.
Weight and dimensions
Number of fibres
Secondary coating
Outer diameter
Weight
4
8
12
24
[mm]
0.9
0.9
0.9
0.9
[mm]
10.2
11.4
12.4
14.0
[kg/km]
140
165
195
240
Tensile strength*
[Inst./oper.]
[N]
700/250
800/350
1200/500
1700/750
Cable properties
*Tensile strength (IEC 60794-1-2E1)
Max tensile load during installation
Max tensile load during operation
Crush (IEC 60794-1-2E3)
Impact (IEC 60794-1-2E4)
Torsion (IEC 60794-1-2E7)
Cable bending
Minimum bending diameter
Cable bend (IEC 60794-1-2E11)
Flexibility (IEC 60794-1-2E8)
Temperature window
See above
See above
Operation
Installation
Storage
-40C to +70C
-10C to +70C
-40C to +70C
2000 N/10cm Water tightness* (IEC 60794-1-2F5B)
1 impacts, 25J Fire and smoke classifications
 1 turn/1m IEC 60332-1
IEC 60332-3-22 (Cat. A)
IEC 60332-3-24 (Cat. C)
15x outer diameter IEC 61034
<0.5 dB/  5 turn IEC 60754-1
1000 cycles
Chemical reistance
Mineral oils IRM 902 (IEC60811-2-1)
Diesel - IRM 903 (IEC60811-2-1)
< 3 m/24 hours
- 7 days /100°C
- 7 days/100°C
*) – Steel wire braiding is not watertight.
Subject to change without prior notice
Page 97 of 212
Ordering information
Part no
Number
of fibres
Cabe Type
Fiber type
Stock
Item
Fiber data
sheet
20116218
*
4
G4-9/125 AICI-I/O/RM/C-W
OS2 Single mode(G652D)
-
C03e
8
G8-9/125 AICI-I/O/RM/C-W
OS2 Single mode(G652D)
-
C03e
*
12
G12-9/125 AICI-I/O/RM/C-W
OS2 Single mode(G652D)
-
C03e
*
24
G24-9/125 AICI-I/O/RM/C-W
OS2 Single mode(G652D)
-
C03e
*
4
G4-50/125 AICI-I/O/RM/C-W
OM2 50/125 multi mode
-
C23
*
8
G8-50/125 AICI-I/O/RM/C-W
OM2 50/125 multi mode
-
C23
C23
886926
12
G12-50/125 AICI-I/O/RM/C-W
OM2 50/125 multi mode
-
*
24
G24-50/125 AICI-I/O/RM/C-W
OM2 50/125 multi mode
-
C23
*
4
G4-50/125OM3 AICI-I/O/RM/C-W
OM3 MaxCap-OM3
-
C31
C31
*
8
G8-50/125OM3 AICI-I/O/RM/C-W
OM3 MaxCap-OM3
-
*
12
G12-50/125OM3 AICI-I/O/RM/C-W
OM3 MaxCap-OM3
-
C31
*
24
G24-50/125OM3 AICI-I/O/RM/C-W
OM3 MaxCap-OM3
-
C31
886701
4
G4-62.5/125 AICI-I/O/RM/C-W
OM1 62.5/125 multi mode
-
C02
C02
886774
8
G8-62.5/125 AICI-I/O/RM/C-W
OM1 62.5/125 multi mode
-
*
12
G12-62.5/125 AICI-I/O/RM/C-W
OM1 62.5/125 multi mode
-
C02
OM1 62.5/125 multi mode
-
C02
*
24
G24-62.5/125 AICI-I/O/RM/C-W
Other fibre types/qualities on request(for example OM4)
*) Part numbers will be given on request. On inquiries or orders, please refer to datasheet number D92aici-mud_e22.doc
Colour code
Fibre
Colour
no.
1
White
2
Red
3
Yellow
4
Green
5
Blue
6
Grey
7
Brown
8
Black
Fibre
no.
9
10
11
12
13
14
15
16
Colour
Violet
Turquise
Orange
Pink
White + marker
Red + marker
Yellow + marker
Green + marker
Fibre
no.
17
18
19
20
21
22
23
24
Colour
Blue + marker
Grey + marker
Brown + marker
Light Blue + marker
Violet + marker
Turquise + marker
Orange + marker
Pink + marker
The outer sheath is as standard dark grey.
Subject to change without prior notice
Page 98 of 212
Optical fibre data sheet
Fibre type
9/125
Fiber data sheet
IEC60793-2-10, 20, 50 cat.
IEC11801 classification
ANSI/TIA/EIA classification
ITU-T type
Core diameter
Mode field diameter
Cladding diameter
Primary coating diameter
(nominal)
Attenuation
(Maximum values)
850 nm
1300 nm
1310 nm
1550 nm
Bandwidth(OFL)
850 nm
1300 nm
Chromatic Dispersion
1285-1330 nm
1550 nm
1625 nm
Polarization Mode Disp.
Max. Individual Fibre
PMDQ Link Design Value
Group index of refraction
850 nm
1300/1310 nm(MMF/SMF)
1550 nm
1625 nm
50/125-OM2
50/125-OM3
62.5/125-OM1
C03
B.1.3
OS2
CAAB
G652.D
C34
A1a.1
OM2
AAAB
G651.1
C31
A1a.2
OM3
AAAC
G651.1
C02
A1b
OM1
AAAA
-
See mode field diameter
1310 nm 9.0  0.4 m
1550 nm 10.1  0.5 m
125  0.7 m
242  7 m
50  2.5 m
50  2.5 m
62.5  2.5 m
125  1.0 m
242  5 m
125  1.0 m
242  5 m
125  1.0 m
242  7 m
 2.7 dB/km
 0.8 dB/km
 2.5 dB/km
 0.8 dB/km
 3.2 dB/km
 1.0 dB/km
>500 MHzkm
>500 MHzkm
>1500 MHzkm
>500 MHzkm
>200 MHzkm
>600 MHzkm
1.482
1.477
1.496
1.491
 0.39 dB/km
 0.25 dB/km
 3 ps/nmkm
 18 ps/nmkm
 22 ps/nmkm
 0.5 ps/√km
 0.2 ps/√km
1.467
1.468
1.468
1.482
1.477
Other fibrequalities/types and qualities are available on request, e.g. OM4 fibre.
Subject to change without prior notice
Page 99 of 212
ICS IE ToughCat 5e S/FTP Installation cable for tougher environments
S/FTP Installation Cable for tougher environments
Application
Generic Data transmission. This cabel is a Cat5e S/FTP cable meant for use as installation(horizontal) cable in tougher
electrical and mechanical environment, including ships and offshore units.
Standards
EN 50173-1; EN 50288-2-1
ISO/IEC 11801; IEC 61156-5
Det Norske Veritas (DNV) spesification No. 6-827.50-2 and Lloyd Register approval system, 2002
Fire rating
LSHF-FR(SHF1)
: IEC 60754-2; IEC 61034, IEC 60332-3-24
Chemical resistance
Mineral oils IRM 902 (IEC60811-2-1)
4 hours/70°C
Diesel - IRM 903 (IEC60811-2-1)
4 hours/70°C
: 7 days/23°C
: 7 days/23°C
Certification
This cable is certified by: Det Norske Veritas (DNV) and Lloyd Register.
Construction
Conductor
Insulation
Twisting
Cable lay up
Pair screen
Overall screen
Sheath
Stranded copper wire Ø 0.22 mm2
PE, Ø 1.4 mm
2 cores to the pair
4 pairs
Al-laminated plastic foil around each pair
Copper braid, tinned Ø 6,2 mm
Oil resistant, Fire retardant and halogen free LSHF-FR(SHF1).
Mechanical Properties
Bending radius
Temperature range
Fire load
Maximum tensile load
Subject to change without prior notice
Without load
With load
During operation
During installation
4 pair
During operation
During installation
8xD
4xD
-40°C to + 85°C
-15°C to + 50°C
515 MJ/km
No load
100 N
Page 100 of 212
Electrical Properties
at 20°C
DC loop resistance
Resistance unbalance
Insulation resistance
Capacitance
Capacitance unbalance
Mean Characteristic impedance
Nominal velocity of propagation
Propagation delay
Delay skew
Transfer impedance
 158 Ω/km
 2%
 5000 MΩxkm
Nom. 43 nF/km
 1500 pF/km
100 ± 5 Ω
0,75c
 450 ns/100 m
 15 ns/100 m
 10 mΩ /m
 8 mΩ /m
 10 mΩ /m
 85 dB
(500 V)
at 800 Hz
(pair to ground)
@ 100 MHz)
at 1 MHz
at 10 MHz
at 30 MHz
Coupling attenuation
Nominal Transmission characteristics
at 20°C
F
Attenuation
NEXT
ACR
Return loss
PS-NEXT
PS-ACR
ELFEXT
PS-ELFEXT
(MHz)
1
(dB/100m)
2,1
(dB)
90
(dB/100m)
88
(dB)
(dB)
87
(dB/100m)
85
(dB/100m)
85
(dB/100m)
82
4
4,0
90
86
27
87
83
85
82
10
6,3
90
84
30
87
81
79
76
16
8,0
90
82
30
87
79
75
72
20
9,0
90
81
30
87
78
73
70
31.25
11,4
90
79
30
87
76
69
66
62.50
16,5
86
70
30
83
67
63
60
100
21,3
83
62
30
80
59
59
56
155.00
24,2
81
57
26
78
54
57
54
200.00
31,5
78
47
25
75
44
53
50
250.00
35,8
77
41
25
74
38
51
48
300.00
47,1
73
26
23
70
23
47
44
600.00
60,1
71
11
20
68
8
44
41
Technical data
Part no.
1000745
Description
ToughCat5 S/FTP 4x2/0,22mm²
Colour
Grey
RAL7035
Outer
diameter
mm
7,6
Fire load
MJ/km
515
Weight
kWh/m
0,143
kg/km
65
Product Code Table
Product Description
ToughCat C5e LSHF-FR 4x2/0.22mm2
ToughCat C5e LSHF-FR 4x2/0.22mm2 500DP
ToughCat C5e LSHF-FR 4x2/0.22mm2 1000DP
Subject to change without prior notice
Product Code
1000745
1000745-00500DP
1000745-01000DP
PG Reference Code
60011599
60011599
60011599
PG Part Number
60011599
60015830
60015833
Page 101 of 212
ICS IE ToughCat 7 S/FTP Installation cable for tougher environments
S/FTP Installation Cable for tougher environments
Application
Generic Data transmission. This cable is a Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher
electrical and mechanical environment, including ships and offshore units.
Standards
EN 50173-1; EN 50288-4-1
ISO/IEC 11801; IEC 61156-5
Det Norske Veritas (DNV) spesification No. 6-827.50-2
Fire rating
LSHF-FR(SHF1)
: IEC 60754-2; IEC 61034, IEC 60332-3-24
Chemical resistance
Mineral oils IRM 902 (IEC60811-2-1)
Diesel - IRM 903 (IEC60811-2-1)
: 7 days/23°C, 4 hours/70°C
: 7 days/23°C, 4 hours/70°C
Certification
This cable is certified by: Det Norske Veritas (DNV) and American Bureau of Shipping (ABS)
Construction
Conductor
Insulation
Twisting
Cable lay up
Pair screen
Overall screen
Sheath
Stranded copper wire Ø 0.27 mm2
PE, Ø 1.6 mm
2 cores to the pair
4 pairs
Al-laminated plastic foil around each pair
Copper braid, tinned Ø 6,6 mm
Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1).
Mechanical Properties
Bending radius
Temperature range
Fire load
Maximum tensile load
Subject to change without prior notice
Without load
With load
During operation
During installation
4 pair
During operation
During installation
8xD
4xD
-40°C to + 85°C
-15°C to + 50°C
670 MJ/km
No load
100 N
Page 102 of 212
Electrical Properties
at 20°C
DC loop resistance
Resistance unbalance
Insulation resistance
Capacitance
Capacitance unbalance
Mean Characteristic impedance
Nominal velocity of propagation
Propagation delay
Delay skew
Transfer impedance
 138 Ω/km
 2%
 5000 MΩxkm
Nom. 43 nF/km
 1500 pF/km
100 ± 5 Ω
0,76c
 450 ns/100 m
 15 ns/100 m
 10 mΩ /m
 8 mΩ /m
 10 mΩ /m
 85 dB
(500 V)
at 800 Hz
(pair to ground)
@ 100 MHz)
at 1 MHz
at 10 MHz
at 30 MHz
Coupling attenuation
Nominal Transmission characteristics
at 20°C
F
Attenuation
NEXT
ACR
Return loss
PS-NEXT
PS-ACR
ELFEXT
PS-ELFEXT
(MHz)
1
(dB/100m)
2,0
(dB)
90
(dB/100m)
88
(dB)
(dB)
87
(dB/100m)
85
(dB/100m)
85
(dB/100m)
82
4
3,6
90
86
27
87
83
85
82
10
5,5
90
84
30
87
81
79
76
16
7,5
90
82
30
87
79
75
72
20
7,7
90
82
30
87
79
73
70
31.25
9,8
90
80
30
87
77
69
66
62.50
14,0
86
72
30
83
69
63
60
100
17,9
83
65
30
80
62
59
56
155.00
22,4
81
59
26
78
55
57
54
200.00
25,6
78
52
25
75
49
53
50
250.00
28,8
77
48
25
74
45
51
48
300.00
31,6
73
41
23
70
38
47
44
600.00
45,7
71
25
20
68
22
44
41
Technical data
Part no.
1016274
Description
ToughCat C7 LSHF-FR
4x2/0.27mm2
Colour
Outer
diamete
r
Grey RAL7035
mm
8,1
Fire load
MJ/km
670
Weight
kWh/m
0,186
kg/km
75
Product Code Table
Product Description
ToughCat C7 LSHF-FR 4x2/0.27mm2
ToughCat C7 LSHF-FR 4x2/0.27mm2 500DP
ToughCat C7 LSHF-FR 4x2/0.27mm2 1000DP
Subject to change without prior notice
Product Code
1016274
1016274-00500DP
PG Reference Code
60011617
60011617
60011617
PG Part Number
60011617
60015820
60030363
Page 103 of 212
ICS IE ToughCat 7S* S/FTP Installation cable for tougher environments
S/FTP Installation Cable for tougher environments
* Version with Solid conductors
Application
Generic Data transmission. This cable is a Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher
electrical and mechanical environment, including ships and offshore units.
Standards
EN 50173-1; EN 50288-4-1
ISO/IEC 11801; IEC 61156-5
Det Norske Veritas (DNV) specification No. 6-827.50-2
Fire rating
LSHF-FR(SHF1)
: IEC 60754-2; IEC 61034, IEC 60332-3-24
Chemical resistance
Mineral oils IRM 902 (IEC60811-2-1)
Diesel - IRM 903 (IEC60811-2-1)
: 7 days/23°C, 4 hours/70°C
: 7 days/23°C, 4 hours/70°C
Certification
This cable is certified by: Det Norske Veritas (DNV)
Construction
Conductor
Insulation
Twisting
Pair screen
Cable lay up
Screen
Sheath
Solid copper wire, Ø 0.56 mm (AWG 23)
foamskin PE, Ø 1.4 mm
2 cores to the pair
Al-laminated plastic foil
4 pairs (PiMF) to the core
copper braid, tinned
Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1).
Mechanical properties
Bending radius
Temperature range
Fire load
Maximum tensile load
Subject to change without prior notice
Without load
With load
During operation
During installation
4 pair
During operation
During installation
8xD
4xD
-40°C to + 85°C
-15°C to + 50°C
670 MJ/km
No load
200 N
Page 104 of 212
Electrical properties
at 20°C± 5°C
Loop resistance
Resistance unbalance
Insulation resistance
Mutual capacitance
Capacitance unbalance
Characteristic impedance
 150 Ω/km
 2%
 5000 MΩ*km
Nom. 43 nF/km
 1500 pF/km
100 ± 5 Ω
100 ± 10 Ω
100 ± 15 Ω
ca. 79 %
 570 ns/100m
 9 ns/100m
1000 V
 10 mΩ/m
 10 mΩ/m
 10 mΩ/m
 20 mΩ/m
 85 dB
(500 V)
at 800 Hz
(pair/ground)
(1-100 MHz)
(100 - 250) MHz
(250 - 600) MHz
Nominal velocity of propagation
Propagation delay
Delay skew
Test voltage
Transfer impedance(Grade 1)
(DC, 1 min) core/core and core/screen
at 1 MHz
at 10 MHz
at 30 MHz
at 100MHz
Coupling attenuation
Electrical data (nominal)
F
(MHZ)
1,0
4,0
10,0
16,0
20,0
31,2
62,5
100,0
125,0
155,5
175,0
200,0
250,0
300,0
450,0
600,0
Attenuation
(dB/100m)
1,8
3,4
5,4
6,8
7,7
9,6
13,7
17,4
19,5
21,9
23,3
25,0
28,1
30,9
38,3
44,8
acc. to Cat.7 (at 20°C)
NEXT
(dB)
100
100
100
100
100
100
100
100
95
94
93
92
90
89
87
85
PS-NEXT
(dB)
97
97
97
97
97
97
97
97
92
91
90
89
87
86
84
82
ACR
(dB/100m)
98
97
95
93
92
90
86
83
75
72
70
67
62
58
48
40
PS-ACR
(dB/100m)
95
94
92
90
89
87
83
80
72
69
67
64
59
55
45
37
ELFEXT
(dB/100m)
105
105
97
93
91
87
81
77
75
73
72
71
69
67
64
61
PS-ELFEXT
(dB/100m)
105
102
94
90
88
84
78
74
72
70
69
68
66
64
61
58
Return loss
(dB)
27
30
30
30
30
30
30
26
26
25
25
24
24
23
22
Technical data
Part no.
1022322
Description
ToughCat7S S/FTP 4x2/0.56
Colour
Grey RAL7035
Outer
diameter
mm
7,6
Fire load
MJ/km
670
Weight
kWh/m
0,186
kg/km
64
Product Code Table
Product Description
ToughCat C7S LSHF-FR 4x2/0.56
ToughCat C7S LSHF-FR 4x2/0.56 500DP
Subject to change without prior notice
Product Code
1022322-00500DP
PG Reference Code
60015280
60015280
PG Part Number
60015280
60015282
Page 105 of 212
ICS IE ToughCat 5e MUD Protected S/FTP Installation cable for tougher environments
S/FTP Installation Cable for tougher environments
Application
Generic Data transmission. This Cat.5e S/FTP cable is based on our DNV and Lloyd Register certified ToughCat, but
with an additional fire retardant, halogen-free, low smoke MUD protecting outer jacket. This cabel is meant for use as
installation/horisontal cable in tougher electrical and mechanical environment, including ships and offshore units.
Standards
EN 50173-1; EN 50288-2-1
ISO/IEC 11801; IEC 61156-5
Fire rating
MUD protecting outer sheath
Inner sheath LSHF-FR(SHF1)
: IEC 60754-2, IEC 61034, IEC 60332-3-24
: IEC 60754-2, IEC 61034, IEC 60332-3-24
Chemical resistance
Mineral oils IRM 902 (IEC60811-2-1)
Diesel - IRM 903 (IEC60811-2-1)
: 7 days/100°C
: 7 days/100°C
Construction
Conductor
Insulation
Twisting
Cable lay up
Pair screen
Overall screen
Inner sheath
Outer sheath
Stranded copper wire Ø 0.22 mm2
PE, Ø 1.4 mm
2 cores to the pair
4 pairs
Al-laminated plastic foil around each pair
Copper braid, tinned Ø 6,2 mm
Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1) Ø 7,7 mm
MUD protecting
Mechanical Properties
Bending radius
Temperature range
Fire load
Maximum tensile load, installation
Subject to change without prior notice
Installation
Installed
During operation
During installation
4 pair
During installation
Installed
8xD
4xD
-40°C to + 85°C
-15°C to + 50°C
(On request) MJ/km
100 N
No load
Page 106 of 212
Electrical Properties
at 20°C
DC loop resistance
Resistance unbalance
Insulation resistance
Capacitance
Capacitance unbalance
Mean Characteristic impedance
Nominal velocity of propagation
Propagation delay
Delay skew
Transfer impedance
 158 Ω/km
 2%
 5000 MΩxkm
Nom. 43 nF/km
 300 pF/km
100 ± 5 Ω
0,75c
 450 ns/100 m
 15 ns/100 m
 10 mΩ /m
 8 mΩ /m
 10 mΩ /m
 85 dB
(500 V)
at 800 Hz
(pair to ground)
@ 100 MHz)
at 1 MHz
at 10 MHz
at 30 MHz
Coupling attenuation
Nominal Transmission characteristics
at 20°C
F
Attenuation
NEXT
ACR
Return loss
PS-NEXT
PS-ACR
ELFEXT
PS-ELFEXT
(MHz)
1
(dB/100m)
2,1
(dB)
90
(dB/100m)
88
(dB)
(dB)
87
(dB/100m)
85
(dB/100m)
85
(dB/100m)
82
4
4,0
90
86
27
87
83
85
82
10
6,3
90
84
30
87
81
79
76
16
8,0
90
82
30
87
79
75
72
20
9,0
90
81
30
87
78
73
70
31.25
11,4
90
79
30
87
76
69
66
62.50
16,5
86
70
30
83
67
63
60
100
21,3
83
62
30
80
59
59
56
155.00
24,2
81
57
26
78
54
57
54
200.00
31,5
78
47
25
75
44
53
50
250.00
35,8
77
41
25
74
38
51
48
300.00
47,1
73
26
23
70
23
47
44
600.00
60,1
71
11
20
68
8
44
41
Technical data
Part no.
1000846
Description
ToughCat MUD C5e S/FTP P
4Px0.22mm2
Colour
Dark Grey
RAL7024
Outer
diameter
mm
9,6
Fire load
MJ/km
*)
Weight
kWh/m
*)
kg/km
100
*)-On request
Product Code Table
Product Description
ToughCat MUD C5e S/FTP P 4Px0.22mm2
ToughCat MUD C5e S/FTP 4Px0.22mm2 500DP
Subject to change without prior notice
Product Code
100846
1000846-00500DP
PG Reference Code
60015701
60015701
PG Part Number
60015701
60015703
Page 107 of 212
ICS IE ToughCat 7 MUD Protected S/FTP Installation cable for tougher environments
S/FTP Installation Cable for tougher environments
Application
Generic Data transmission. This cable is a Cat7 S/FTP cable is based on our DNV certified ToughCat, but with
an additional fire retardant, halogen-free, low smoke MUD protecting outer jacket. This cabel is meant for use as
installation/horisontal cable in tougher electrical and mechanical environment, including ships and offshore units.
Standards
EN 50173-1; EN 50288-4-1
ISO/IEC 11801; IEC 61156-5
Fire rating
Inner sheath: LSHF-FR (SHF1)
MUD protecting outer sheath
: IEC 60754-2; IEC 61034, IEC 60332-3-24
: IEC 60754-2; IEC 61034, IEC 60332-3-24
Chemical resistance
Mineral oils IRM 902 (IEC60811-2-1)
Diesel - IRM 903 (IEC60811-2-1)
: - 7 days/100°C
: - 7 days/100°C
Certification
Pending.
Construction
Conductor
Insulation
Twisting
Cable lay up
Pair screen
Overall screen
Inner sheath
Outer sheath
Stranded copper wire Ø 0.27 mm2
PE, Ø 1.6 mm
2 cores to the pair
4 pairs
Al-laminated plastic foil around each pair
Copper braid, tinned Ø 6,6 mm
Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1).
MUD protecting
Mechanical Properties
Bending radius
Temperature range
Fire load
Maximum tensile load
Subject to change without prior notice
Without load
With load
During operation
During installation
4 pair
During operation
During installation
8xD
4xD
-40°C to + 85°C
-15°C to + 50°C
(on request) MJ/km
No load
100 N
Page 108 of 212
Electrical Properties
at 20°C
DC loop resistance
Resistance unbalance
Insulation resistance
Capacitance
Capacitance unbalance
Mean Characteristic impedance
Nominal velocity of propagation
Propagation delay
Delay skew
Transfer impedance
 138 Ω/km
 2%
 5000 MΩxkm
Nom. 43 nF/km
 1500 pF/km
100 ± 5 Ω
0,76c
 450 ns/100 m
 15 ns/100 m
 10 mΩ /m
 8 mΩ /m
 10 mΩ /m
 85 dB
(500 V)
at 800 Hz
(pair to ground)
@ 100 MHz)
at 1 MHz
at 10 MHz
at 30 MHz
Coupling attenuation
Nominal Transmission characteristics
at 20°C
F
Attenuation
NEXT
ACR
Return loss
PS-NEXT
PS-ACR
ELFEXT
PS-ELFEXT
(MHz)
1
(dB/100m)
2,0
(dB)
90
(dB/100m)
88
(dB)
(dB)
87
(dB/100m)
85
(dB/100m)
85
(dB/100m)
82
4
3,6
90
86
27
87
83
85
82
10
5,5
90
84
30
87
81
79
76
16
7,5
90
82
30
87
79
75
72
20
7,7
90
82
30
87
79
73
70
31.25
9,8
90
80
30
87
77
69
66
62.50
14,0
86
72
30
83
69
63
60
100
17,9
83
65
30
80
62
59
56
155.00
22,4
81
59
26
78
55
57
54
200.00
25,6
78
52
25
75
49
53
50
250.00
28,8
77
48
25
74
45
51
48
300.00
31,6
73
41
23
70
38
47
44
600.00
45,7
71
25
20
68
22
44
41
Technical data
Part no.
1019269
Description
ToughCat MUD C7 S/FTP
4Px0.27mm2
Colour
Grey RAL7024
Outer
diameter
mm
10,1
Fire load
MJ/km
*)
Weight
kWh/m
*)
kg/km
112
*) on request
Product Code Table
Product Description
ToughCat MUD C7 S/FTP 4Px0.27mm2
ToughCat MUD C7 S/FTP 4Px0.27mm2 500DP
Subject to change without prior notice
Product Code
1019269-00500DP
PG Reference Code
60015692
60015692
PG Part Number
60015692
60015695
Page 109 of 212
ICS IE ToughCat 7S* MUD Protected S/FTP Installation cable for tougher environments
S/FTP Installation Cable for tougher environments
* Version with Solid conductors
Application
Generic Data transmission. This cable is a Cat7 S/FTP cable is based on our DNV certified ToughCat, but with
an additional fire retardant, halogen-free, low smoke MUD protecting outer jacket. This cabel is meant for use as
installation/horisontal cable in tougher electrical and mechanical environment, including ships and offshore units.
Standards
EN 50173-1; EN 50288-4-1
ISO/IEC 11801; IEC 61156-5
Fire rating
Inner sheath: LSHF-FR (SHF1)
MUD protecting outer sheath
: IEC 60754-2; IEC 61034, IEC 60332-3-24
: IEC 60754-2; IEC 61034, IEC 60332-3-24
Chemical resistance
Mineral oils IRM 902 (IEC60811-2-1)
Diesel - IRM 903 (IEC60811-2-1)
: - 7 days/100°C
: - 7 days/100°C
Certification
The base construction(exclusive the extra MUD sheath) is certified by DnV.
Construction
Conductor
Insulation
Twisting
Pair screen
Cable lay up
Screen
Inner sheath
Outer sheath
Solid copper wire, Ø 0.56 mm (AWG 23)
foamskin PE, Ø 1.4 mm
2 cores to the pair
Al-laminated plastic foil
4 pairs (PiMF) to the core
copper braid, tinned
Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1).
MUD protecting
Mechanical properties
Bending radius
Temperature range
Fire load
Maximum tensile load
Subject to change without prior notice
Without load
With load
During operation
During installation
4 pair
During operation
During installation
8xD
4xD
-40°C to + 85°C
-15°C to + 50°C
670 MJ/km
No load
200 N
Page 110 of 212
Electrical properties
at 20°C± 5°C
Loop resistance
Resistance unbalance
Insulation resistance
Mutual capacitance
Capacitance unbalance
Characteristic impedance
 155 Ω/km
 2%
 5000 MΩ*km
Nom. 43 nF/km
 1500 pF/km
100 ± 5 Ω
100 ± 10 Ω
100 ± 15 Ω
ca. 79 %
 570 ns/100m
 9 ns/100m
1000 V
 10 mΩ/m
 10 mΩ/m
 10 mΩ/m
 20 mΩ/m
 85 dB
(500 V)
at 800 Hz
(pair/ground)
(1-100 MHz)
(100 - 250) MHz
(250 - 600) MHz
Nominal velocity of propagation
Propagation delay
Delay skew
Test voltage
Transfer impedance(Grade 1)
(DC, 1 min) core/core and core/screen
at 1 MHz
at 10 MHz
at 30 MHz
at 100MHz
Coupling attenuation
Electrical data (nominal)
F
(MHZ)
1,0
4,0
10,0
16,0
20,0
31,2
62,5
100,0
125,0
155,5
175,0
200,0
250,0
300,0
450,0
600,0
Attenuation
(dB/100m)
1,8
3,4
5,4
6,8
7,7
9,6
13,7
17,4
19,5
21,9
23,3
25,0
28,1
30,9
38,3
44,8
acc. to Cat.7 (at 20°C)
NEXT
(dB)
100
100
100
100
100
100
100
100
95
94
93
92
90
89
87
85
PS-NEXT
(dB)
97
97
97
97
97
97
97
97
92
91
90
89
87
86
84
82
ACR
(dB/100m)
98
97
95
93
92
90
86
83
75
72
70
67
62
58
48
40
PS-ACR
(dB/100m)
95
94
92
90
89
87
83
80
72
69
67
64
59
55
45
37
ELFEXT
(dB/100m)
105
105
97
93
91
87
81
77
75
73
72
71
69
67
64
61
PS-ELFEXT
(dB/100m)
105
102
94
90
88
84
78
74
72
70
69
68
66
64
61
58
Return loss
(dB)
27
30
30
30
30
30
30
26
26
25
25
24
24
23
22
Technical data
Part no.
1026769
*)-On request
Description
ToughCat MUD C7S 4x2/0.56
Colour
Dark Grey
RAL7024
Outer
diameter
mm
9,6
Fire load
MJ/km
*)
Weight
kWh/m
*)
kg/km
100
Product Code Table
Product Description
ToughCat MUD C7S 4x2/0.56 500DP
ToughCat MUD C7S 4x2/0.56
Subject to change without prior notice
Product Code
1026769-00500DP
1026769
PG Reference Code
60022014
60022014
PG Part Number
60015706
60022014
Page 111 of 212
ARCTIC GRADE instrumentation cable RFOU(i) 150/250(300)V, S1/S5
Flame retardant halogen-free
instrumentation cable. Oil & Mud resistant.
Cold bend / Cold impact resistant
RFOU(i)
150/250(300)V
EPR/EPR/TCWB/EVA
NEK TS 606 CodeS1/S5 Arctic Grade
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
IEC 60092-376 (2003-05)
- Design
IEC
60228
class
2
- Conductor
Fixed installation for instrumentation, communication,
IEC
60092-360
- Insulation
Control and alarm systems in both EX- and safe areas.
IEC
60092-360
- Sheath
For installation in areas exposed to MUD and
IEC
60332-1-2
- Flame Retardant
drilling/cleaning fluids. Meets the OIL & MUD
IEC
60332-3-22
- Flame Retardant
resistance requirement in NEK TS 606:2009. Meets the
IEC
60754-1,2
- Halogen Free
cold bend / cold impact requirement in CSA 22.2 0.3IEC
61034-1,2
- Low Smoke
01 and IEC 60092-350 Clause 8.9 & Annex E at -40°C
CSA 22.2 0.3-01 (-40°C/-35°C)
/ -35°C.
- Cold Bend /
/ IEC 60092-352 Annex E
Cold Impact
(-40°C/-35°C)
Construction
Code
Letter
Conductor
Insulation
R
Pair / Triple /
Quad twisting
Lay up /
Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbers printed directly on the insulated conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and
wrapped with a PETP tape.
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
Rubberized Polyamide tape
U
Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset
compound, SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 01 RFOU(I) 250V S1/S5 4PAIR 0.75mm2 IEC 60092376 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35
deg. C)
DRAKA 01 = Draka Norsk Kabel,
Grey or Blue
Subject to change without prior notice
Page 112 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Number No of
of
cores in
elements element
Cross
section
core,
mm²
Conductor
Diameter,
mm
Insulation
Thickness,
mm
Thickness
Inner
covering,
mm
Diameter
inner
covering,
mm
Thickness
Diameter
Outer
Braid
Sheath,
Wire, mm
mm
Diameter
outer
sheath,
mm
Weight of
Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
1
1
2
2
4
4
8
8
16
16
24
24
2
2
2
2
2
2
2
2
2
2
2
2
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.9
1.9
2.1
2.1
7 ± 0.5
7 ± 0.5
10 ± 0.8
10 ± 0.8
11.5 ± 0.8
11.5 ± 0.8
15.5 ± 0.8
15.5 ± 0.8
21.5 ± 1
21.5 ± 1
26.5 ± 1
26.5 ± 1
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.1
1.1
1.2
1.2
1.3
1.3
1.5
1.5
1.7
1.7
1.9
1.9
10 ± 0.8
10 ± 0.8
13 ± 0.8
13 ± 0.8
15.5 ± 0.8
15.5 ± 0.8
19.5 ± 0.8
19.5 ± 0.8
26.5 ± 1
26.5 ± 1
31.5 ± 1.5
31.5 ± 1.5
185
185
280
280
430
430
690
690
1240
1240
1720
1720
54
54
85
85
166
166
265
265
439
439
596
596
1
1
2
2
4
4
8
8
16
16
24
24
3
3
3
3
3
3
3
3
3
3
3
3
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
2.1
2.1
2.5
2.5
7.5 ± 0.5
7.5 ± 0.5
11 ± 0.8
11 ± 0.8
12.5 ± 0.8
12.5 ± 0.8
17 ± 0.8
17 ± 0.8
24.5 ± 1
24.5 ± 1
30.5 ± 1.5
30.5 ± 1.5
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.1
1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.8
1.8
2
2
10.5 ± 0.8
10.5 ± 0.8
15 ± 0.8
15 ± 0.8
17 ± 0.8
17 ± 0.8
21.5 ± 1
21.5 ± 1
29.5 ± 1
29.5 ± 1
36 ± 1.5
36 ± 1.5
200
200
360
360
510
510
810
810
1540
1540
2240
2240
60
60
130
130
192
192
318
318
544
544
778
778
1
1
2
2
4
4
8
8
12
16
16
24
24
2
2
2
2
2
2
2
2
2
2
2
2
2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.4
1.9
1.9
2.3
2.3
8 ± 0.5
8 ± 0.5
12 ± 0.8
12 ± 0.8
14 ± 0.8
14 ± 0.8
19 ± 0.8
19 ± 0.8
23 ± 1
26.5 ± 1
26.5 ± 1
33 ± 1.5
33 ± 1.5
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
1.1
1.1
1.3
1.3
1.4
1.4
1.6
1.6
1.8
1.9
1.9
2.2
2.2
11.5 ± 0.8
11.5 ± 0.8
16 ± 0.8
16 ± 0.8
18 ± 0.8
18 ± 0.8
23.5 ± 1
23.5 ± 1
28 ± 1
32 ± 1.5
32 ± 1.5
39 ± 1.5
39 ± 1.5
230
230
420
420
600
600
980
980
1380
1820
1820
2770
2770
71
71
168
168
252
252
420
420
580
740
740
1165
1165
1
1
2
4
4
8
8
16
16
24
24
3
3
3
3
3
3
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.1
1.1
1.1
1.1
1.1
1.1
1.1
2.3
2.3
2.5
2.5
8.5 ± 0.5
8.5 ± 0.5
13.5 ± 0.8
15.5 ± 0.8
15.5 ± 0.8
21.5 ± 1
21.5 ± 1
31 ± 1.5
31 ± 1.5
38 ± 1.5
38 ± 1.5
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
1.1
1.1
1.4
1.5
1.5
1.7
1.7
2
2
2.3
2.3
12 ± 0.8
12 ± 0.8
17.5 ± 0.8
20 ± 1
20 ± 1
26 ± 1
26 ± 1
36.5 ± 1.5
36.5 ± 1.5
44 ± 2
44 ± 2
265
265
510
740
740
1230
1230
2410
2410
3550
3550
93
93
213
325
325
558
558
992
992
1551
1551
1
2
4
2
2
2
2.5
2.5
2.5
2
2
2
0.7
0.7
0.7
1.1
1.1
1.1
9 ± 0.5
0.2
13.5 ± 0.8 0.3
16 ± 0.8
0.3
1.1
1.4
1.5
12.5 ± 0.8 280
17.5 ± 0.8 530
20.5 ± 1
770
Subject to change without prior notice
Page 113 of 212
99
225
350
Electrical values instrumentation cables
Type
Shielded pair 0,75 mm²
Shielded triple 0,75 mm²
Shielded pair 1,5 mm²
Shielded triple 1,5 mm²
Shielded pair 2,5 mm²
Shielded triple 2,5 mm²
Shielded 16 and 24 triple 1,5 mm²
Capacitance,
approx. (nF/km)
110
110
125
125
145
145
105
Inductance, approx,
(mH/km)
0,67
0,67
0,63
0,63
0,59
0,59
0,71
Resistance at 20°C, max.
(Ohm/km)
26,3
26,3
12,9
12,9
8,02
8,02
12,9
L/R ratio, (microH/Ohm)
12,7
12,7
24,4
24,4
36,8
36,8
24,4
Ordering information
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
812000
812001
812006
812007
812018
812019
812030
812031
812042
812043
812048
812049
RFOU(I) 1PAIR 0.75mm² S1/S5 Cold
RFOU(I) 1PAIR 0.75mm² S1/S5 Cold
RFOU(I) 2PAIR 0.75mm² S1/S5 Cold
RFOU(I) 2PAIR 0.75mm² S1/S5 Cold
RFOU(I) 4PAIR 0.75mm² S1/S5 Cold
RFOU(I) 4PAIR 0.75mm² S1/S5 Cold
RFOU(I) 8PAIR 0.75mm² S1/S5 Cold
RFOU(I) 8PAIR 0.75mm² S1/S5 Cold
RFOU(I) 16PAIR 0.75mm² S1/S5 Cold
RFOU(I) 16PAIR 0.75mm² S1/S5 Cold
RFOU(I) 24PAIR 0.75mm² S1/S5 Cold
RFOU(I) 24PAIR 0.75mm² S1/S5 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528120004
7021528120011
7021528120066
7021528120073
7021528120189
7021528120196
7021528120301
7021528120318
7021528120424
7021528120431
7021528120486
7021528120493
-
812060
812061
812066
812067
812078
812079
812090
812091
812102
812103
812108
812109
RFOU(I) 1TRIP 0.75mm² S1/S5 Cold
RFOU(I) 1TRIP 0.75mm² S1/S5 Cold
RFOU(I) 2TRIP 0.75mm² S1/S5 Cold
RFOU(I) 2TRIP 0.75mm² S1/S5 Cold
RFOU(I) 4TRIP 0.75mm² S1/S5 Cold
RFOU(I) 4TRIP 0.75mm² S1/S5 Cold
RFOU(I) 8TRIP 0.75mm² S1/S5 Cold
RFOU(I) 8TRIP 0.75mm² S1/S5 Cold
RFOU(I) 16TRIP 0.75mm² S1/S5 Cold
RFOU(I) 16TRIP 0.75mm² S1/S5 Cold
RFOU(I) 24TRIP 0.75mm² S1/S5 Cold
RFOU(I) 24TRIP 0.75mm² S1/S5 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528120608
7021528120615
7021528120660
7021528120677
7021528120783
7021528120790
7021528120905
7021528120912
7021528121025
7021528121032
7021528121087
7021528121094
-
812200
812201
812206
812207
812218
812219
812230
812231
812236
812242
812243
812248
812249
RFOU(I) 1PAIR 1.5mm² S1/S5 Cold
RFOU(I) 1PAIR 1.5mm² S1/S5 Cold
RFOU(I) 2PAIR 1.5mm² S1/S5 Cold
RFOU(I) 2PAIR 1.5mm² S1/S5 Cold
RFOU(I) 4PAIR 1.5mm² S1/S5 Cold
RFOU(I) 4PAIR 1.5mm² S1/S5 Cold
RFOU(I) 8PAIR 1.5mm² S1/S5 Cold
RFOU(I) 8PAIR 1.5mm² S1/S5 Cold
RFOU(I) 12PAIR 1.5mm² S1/S5 Cold
RFOU(I) 16PAIR 1.5mm² S1/S5 Cold
RFOU(I) 16PAIR 1.5mm² S1/S5 Cold
RFOU(I) 24PAIR 1.5mm² S1/S5 Cold
RFOU(I) 24PAIR 1.5mm² S1/S5 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
-
7021528122008
7021528122015
7021528122060
7021528122077
7021528122183
7021528122190
7021528122305
7021528122312
7021528122367
7021528122428
7021528122435
7021528122480
7021528122497
-
812260
812261
812266
812278
812279
812290
812291
812302
812303
812308
812309
RFOU(I) 1TRIP 1.5mm² S1/S5 Cold
RFOU(I) 1TRIP 1.5mm² S1/S5 Cold
RFOU(I) 2TRIP 1.5mm² S1/S5 Cold
RFOU(I) 4TRIP 1.5mm² S1/S5 Cold
RFOU(I) 4TRIP 1.5mm² S1/S5 Cold
RFOU(I) 8TRIP 1.5mm² S1/S5 Cold
RFOU(I) 8TRIP 1.5mm² S1/S5 Cold
RFOU(I) 16TRIP 1.5mm² S1/S5 Cold
RFOU(I) 16TRIP 1.5mm² S1/S5 Cold
RFOU(I) 24TRIP 1.5mm² S1/S5 Cold
RFOU(I) 24TRIP 1.5mm² S1/S5 Cold
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528122602
7021528122619
7021528122664
7021528122787
7021528122794
7021528122909
7021528122916
7021528123029
7021528123036
7021528123081
7021528123098
-
812400
812406
812418
RFOU(I) 1PAIR 2.5mm² S1/S5 Cold
RFOU(I) 2PAIR 2.5mm² S1/S5 Cold
RFOU(I) 4PAIR 2.5mm² S1/S5 Cold
GREY
GREY
GREY
-
7021528124002
7021528124064
7021528124187
-
Subject to change without prior notice
Page 114 of 212
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-40°C
Page 115 of 212
ARCTIC GRADE instrumentation cable RFOU(c) 150/250(300)V, S2/S6
Flame retardant halogen-free instrumentation
cable. Oil & Mud resistant. Cold bend / Cold
impact resistant
RFOU(c) 150/250(300)V
EPR/EPR/TCWB/EVA
NEK TS 606 CodeS2/S6 Arctic Grade
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation,
communication, Control and alarm systems in both
EX- and safe areas. For installation in areas
exposed to MUD and drilling/cleaning fluids. Meets
the OIL & MUD resistance requirement in NEK TS
606:2009. Meets the cold bend / cold impact
requirement in CSA 22.2 0.3-01 and IEC 60092350 Clause 8.9 & Annex E at -40°C / -35°C.
IEC 60092-376 (2003-05)
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
CSA 22.2 0.3-01 (-40°C/-35°C) /
IEC 60092-352 Annex E (-40°C/35°C)
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
- Cold Bend /
Cold Impact
Construction
Code
Letter
Conductor
Insulation
R
Pair / Triple /
Quad twisting
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire. Pairs/triples are identified by numbers printed directly on the
insulated conductors.
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
Rubberized Polyamide tape
U
Flame retardant, halogen-free, mud and cold bend / cold impact resistant
thermoset compound, SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 01 RFOU(C) 250V S2/S6 4PAIR 0.75mm2 IEC 60092376 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35
deg. C)
DRAKA 01 = Draka Norsk Kabel,
Marking text
Manufacturing
unit
Outer sheath
colour
Subject to change without prior notice
Grey or Blue
Page 116 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Number No of
of
cores in
elements element
Cross
section
core,
mm²
Conductor
Diameter,
mm
Insulation
Thickness,
mm
Thickness
Inner
covering,
mm
Diameter
inner
covering,
mm
Thickness
Diameter
Outer
Braid
Sheath,
Wire, mm
mm
Diameter
outer
sheath,
mm
Weight of
Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
2
2
4
4
8
8
16
16
24
24
2
2
2
2
2
2
2
2
2
2
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1.1
1.1
1.1
1.1
1.1
1.1
1.9
1.9
2.1
2.1
10 ± 0.8
10 ± 0.8
11.5 ± 0.8
11.5 ± 0.8
15 ± 0.8
15 ± 0.8
20.5 ± 1
20.5 ± 1
25 ± 1
25 ± 1
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
1.2
1.3
1.3
1.4
1.4
1.6
1.6
1.8
1.8
13.5 ± 0.8
13.5 ± 0.8
15.5 ± 0.8
15.5 ± 0.8
19.5 ± 0.8
19.5 ± 0.8
25 ± 1
25 ± 1
29.5 ± 1
29.5 ± 1
275
275
390
390
600
600
1040
1040
1450
1450
81
81
138
138
223
223
358
358
510
510
2
2
4
4
8
8
16
24
24
3
3
3
3
3
3
3
3
3
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1.1
1.1
1.1
1.1
1.1
1.1
2.1
2.3
2.3
11 ± 0.8
11 ± 0.8
12.5 ± 0.8
12.5 ± 0.8
17 ± 0.8
17 ± 0.8
23 ± 1
28 ± 1
28 ± 1
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
1.2
1.3
1.3
1.5
1.5
1.7
1.9
1.9
14.5 ± 0.8
14.5 ± 0.8
16.5 ± 0.8
16.5 ± 0.8
21 ± 1
21 ± 1
27.5 ± 1
33 ± 1.5
33 ± 1.5
320
320
470
470
740
740
1350
1860
1860
95
95
181
181
291
291
488
667
667
2
2
4
4
8
8
16
16
24
2
2
2
2
2
2
2
2
2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.1
1.1
1.1
1.1
1.1
1.1
1.9
1.9
2.3
12 ± 0.8
12 ± 0.8
14 ± 0.8
14 ± 0.8
18.5 ± 0.8
18.5 ± 0.8
25 ± 1
25 ± 1
31 ± 1.5
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.3
1.3
1.4
1.4
1.6
1.6
1.8
1.8
2.1
16 ± 0.8
16 ± 0.8
18 ± 0.8
18 ± 0.8
23 ± 1
23 ± 1
30 ± 1.5
30 ± 1.5
36.5 ± 1.5
410
410
560
560
890
890
1580
1580
2270
162
162
234
234
379
379
651
651
924
2
4
8
16
16
24
24
3
3
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.1
1.1
1.1
2.1
2.1
2.5
2.5
13 ± 0.8
15.5 ± 0.8
21 ± 1
28 ± 1
28 ± 1
35 ± 1.5
35 ± 1.5
0.3
0.3
0.3
0.3
0.3
0.4
0.4
1.4
1.4
1.7
1.9
1.9
2.2
2.2
17.5 ± 0.8
19.5 ± 0.8
25.5 ± 1
33 ± 1.5
33 ± 1.5
41 ± 2
41 ± 2
490
670
1140
2090
2090
3100
3100
190
291
517
903
903
1369
1369
2
4
4
12
2
2
2
2
2.5
2.5
2.5
2.5
2
2
2
2
0.7
0.7
0.7
0.7
1.1
1.1
1.1
2.1
13.5 ± 0.8
16 ± 0.8
16 ± 0.8
27 ± 1
0.3
0.3
0.3
0.3
1.4
1.4
1.4
1.8
17.5 ± 0.8
20 ± 1
20 ± 1
31.5 ± 1.5
490
680
680
1730
200
309
309
759
Subject to change without prior notice
Page 117 of 212
Electrical values instrumentation cables
Type
Unshielded pair 0,75 mm²
Unshielded triple 0,75 mm²
Unshielded pair 1,5 mm²
Unshielded triple 1,5 mm²
Unshielded pair 2,5 mm²
Unshielded triple 2,5 mm²
Unshielded 24 pair 2,5 mm²
Unshielded 16 triple 2,5 mm²
Capacitance, approx.
(nF/km)
100
100
110
110
125
125
95
95
Inductance, approx,
(mH/km)
0,67
0,67
0,63
0,63
0,59
0,59
0,66
0,66
Resistance at 20°C, max.
(Ohm/km)
26,3
26,3
12,9
12,9
8,02
8,02
8,02
8,02
L/R ratio,
(microH/Ohm)
12,7
12,7
24,4
24,4
36,8
36,8
36,8
36,8
Ordering information
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
812606
812607
812618
812619
812630
812631
812642
812643
812648
812649
RFOU(C) 2PAIR 0.75mm² S2/S6 Cold
RFOU(C) 2PAIR 0.75mm² S2/S6 Cold
RFOU(C) 4PAIR 0.75mm² S2/S6 Cold
RFOU(C) 4PAIR 0.75mm² S2/S6 Cold
RFOU(C) 8PAIR 0.75mm² S2/S6 Cold
RFOU(C) 8PAIR 0.75mm² S2/S6 Cold
RFOU(C) 16PAIR 0.75mm² S2/S6 Cold
RFOU(C) 16PAIR 0.75mm² S2/S6 Cold
RFOU(C) 24PAIR 0.75mm² S2/S6 Cold
RFOU(C) 24PAIR 0.75mm² S2/S6 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528126068
7021528126075
7021528126181
7021528126198
7021528126303
7021528126310
7021528126426
7021528126433
7021528126488
7021528126495
-
812666
812667
812678
812679
812690
812691
812702
812708
812709
RFOU(C) 2TRIP 0.75mm² S2/S6 Cold
RFOU(C) 2TRIP 0.75mm² S2/S6 Cold
RFOU(C) 4TRIP 0.75mm² S2/S6 Cold
RFOU(C) 4TRIP 0.75mm² S2/S6 Cold
RFOU(C) 8TRIP 0.75mm² S2/S6 Cold
RFOU(C) 8TRIP 0.75mm² S2/S6 Cold
RFOU(C) 16TRIP 0.75mm² S2/S6 Cold
RFOU(C) 24TRIP 0.75mm² S2/S6 Cold
RFOU(C) 24TRIP 0.75mm² S2/S6 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
-
7021528126662
7021528126679
7021528126785
7021528126792
7021528126907
7021528126914
7021528127027
7021528127089
7021528127096
-
812806
812807
812818
812819
812830
812831
812842
812843
812848
RFOU(C) 2PAIR 1.5mm² S2/S6 Cold
RFOU(C) 2PAIR 1.5mm² S2/S6 Cold
RFOU(C) 4PAIR 1.5mm² S2/S6 Cold
RFOU(C) 4PAIR 1.5mm² S2/S6 Cold
RFOU(C) 8PAIR 1.5mm² S2/S6 Cold
RFOU(C) 8PAIR 1.5mm² S2/S6 Cold
RFOU(C) 16PAIR 1.5mm² S2/S6 Cold
RFOU(C) 16PAIR 1.5mm² S2/S6 Cold
RFOU(C) 24PAIR 1.5mm² S2/S6 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
-
7021528128062
7021528128079
7021528128185
7021528128192
7021528128307
7021528128314
7021528128420
7021528128437
7021528128482
-
812866
812878
812891
812902
812903
812908
812909
RFOU(C) 2TRIP 1.5mm² S2/S6 Cold
RFOU(C) 4TRIP 1.5mm² S2/S6 Cold
RFOU(C) 8TRIP 1.5mm² S2/S6 Cold
RFOU(C) 16TRIP 1.5mm² S2/S6 Cold
RFOU(C) 16TRIP 1.5mm² S2/S6 Cold
RFOU(C) 24TRIP 1.5mm² S2/S6 Cold
RFOU(C) 24TRIP 1.5mm² S2/S6 Cold
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528128666
7021528128789
7021528128918
7021528129021
7021528129038
7021528129083
7021528129090
-
813006
813018
813019
813036
RFOU(C) 2PAIR 2.5mm² S2/S6 Cold
RFOU(C) 4PAIR 2.5mm² S2/S6 Cold
RFOU(C) 4PAIR 2.5mm² S2/S6 Cold
RFOU(C) 12PAIR 2.5mm² S2/S6 Cold
GREY
GREY
BLUE
GREY
-
7021528130065
7021528130188
7021528130195
7021528130362
-
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-40°C
Page 118 of 212
ARCTIC GRADE Fire resistant, instrumentation cable BFOU(i) 150/250(300)V, S3/S7
Fire resistant, flame retardant halogen-free
instrumentation cable. Oil & Mud resistant.
Cold bend / Cold impact resistant
BFOU(i) 150/250(300)V
MGT/EPR/EPR/TCWB/EVA
NEK TS 606 CodeS3/S7 Arctic Grade
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation,
communication, control and alarm systems in both
EX- and safe areas, emergency and critical
systems where requirement for fire resistance
exists. Meets the OIL & MUD resistance
requirement in NEK TS 606:2009. Meets the cold
bend / cold impact requirement in CSA 22.2 0.3-01
and IEC 60092-350 Clause 8.9 & Annex E at 40°C/-35°C.
IEC 60092-376 (2003-05)
- Design
IEC 60228 class 2
- Conductor
IEC 60092-360
- Insulation
IEC 60092-360
- Sheath
IEC 60332-1-2
- Flame Retardant
IEC 60332-3-22
- Flame Retardant
IEC 60331-1, -2, -21
- Fire Resistant
IEC 60754-1,2
- Halogen Free
IEC 61034-1,2
- Low Smoke
CSA 22.2 0.3-01 (-40°C/-35°C) /
- Cold Bend /
IEC 60092-350 Annex E (Cold Impact
40°C/-35°C)
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Lay up /
Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and
wrapped with a PETP tape.
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned annealed copper wire braid
Rubberized Polyamide tape
U
Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset
compound, SHF2 (IEC 60092-360)
Eg. "meter" "year" DRAKA 01 BFOU(I) 250V S3/S7 4PAIR 0.75mm2 FLEX FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21 IEC 603323-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C)
DRAKA 01 = Draka Norsk Kabel
Grey or Blue
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
Subject to change without prior notice
Page 119 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
1
2
0.75
1.1
0.6
1.1
7.5 ± 0.5 0.2
3.8
1.1
1
2
0.75
1.1
0.6
1.1
7.5 ± 0.5 0.2
3.8
1.1
2
2
0.75
1.1
0.6
1.1
11 ± 0.8
0.3
10.2
1.3
2
2
0.75
1.1
0.6
1.1
11 ± 0.8
0.3
10.2
1.3
4
2
0.75
1.1
0.6
1.1
0.3
11.9
1.4
4
2
0.75
1.1
0.6
1.1
8
8
16
16
2
2
2
2
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
24
2
0.75
1.1
24
2
0.75
1
1
2
2
4
4
3
3
3
3
3
3
8
0.3
11.9
1.4
1.1
1.1
1.9
1.9
12.5 ±
0.8
12.5 ±
0.8
17 ± 0.8
17 ± 0.8
24 ± 1
24 ± 1
0.3
0.3
0.3
0.3
15.3
15.3
20.4
20.4
1.6
1.6
1.8
1.8
0.6
2.3
30 ± 1.5
0.3
25.4
2
1.1
0.6
2.3
30 ± 1.5
0.3
25.4
2
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
0.6
0.6
1.1
1.1
1.1
1.1
1.1
1.1
0.2
0.2
0.3
0.3
0.3
0.3
4.5
4.5
10.2
10.2
11.9
11.9
1.1
1.1
1.4
1.4
1.4
1.4
3
0.75
1.1
0.6
1.1
0.3
17.8
8
3
0.75
1.1
0.6
1.1
0.3
16
24
24
3
3
3
0.75
0.75
0.75
1.1
1.1
1.1
0.6
0.6
0.6
2.1
2.5
2.5
8 ± 0.5
8 ± 0.5
12 ± 0.8
12 ± 0.8
14 ± 0.8
14 ± 0.8
18.5 ±
0.8
18.5 ±
0.8
26.5 ± 1
33 ± 1.5
33 ± 1.5
1
1
2
2
2
2
2
2
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
1.1
1.1
1.1
1.1
4
2
1.5
1.6
0.7
1.1
4
2
1.5
1.6
0.7
1.1
8
8
2
2
1.5
1.5
1.6
1.6
0.7
0.7
12
2
1.5
1.6
16
2
1.5
16
2
24
Diameter
outer
sheath,
mm
10.5 ±
0.8
10.5 ±
0.8
14.5 ±
0.8
14.5 ±
0.8
16.5 ±
0.8
16.5 ±
0.8
21.5 ± 1
21.5 ± 1
29 ± 1
29 ± 1
35.5 ±
1.5
35.5 ±
1.5
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
200
54
200
54
360
133
360
133
490
183
490
183
780
780
1400
1400
283
283
465
465
2020
647
2020
647
11 ± 0.8
11 ± 0.8
16 ± 0.8
16 ± 0.8
18 ± 0.8
18 ± 0.8
225
225
410
410
570
570
68
68
146
146
209
209
1.7
23 ± 1
960
359
17.8
1.7
23 ± 1
960
359
0.3
0.4
0.4
22.9
36.2
36.2
1.9
2.2
2.2
32 ± 1.5
39 ± 1.5
39 ± 1.5
1770
2620
2620
594
909
909
0.2
0.2
0.3
0.3
4.5
4.5
11.9
11.9
1.1
1.1
1.4
1.4
79
79
184
184
0.3
13.6
1.5
670
269
0.3
13.6
1.5
670
269
0.3
0.3
17.8
17.8
1.7
1.7
1090
1090
446
446
0.7
1.4
25.5 ± 1
0.3
20.4
1.9
1560
606
1.6
0.7
2.1
30 ± 1.5
0.3
22.9
2
2080
766
1.5
1.6
0.7
2.1
30 ± 1.5
0.3
22.9
2
12 ± 0.8
12 ± 0.8
17 ± 0.8
17 ± 0.8
19.5 ±
0.8
19.5 ±
0.8
25.5 ± 1
25.5 ± 1
30.5 ±
1.5
35.5 ±
1.5
35.5 ±
1.5
255
255
480
480
1.1
1.1
9 ± 0.5
9 ± 0.5
13 ± 0.8
13 ± 0.8
15.5 ±
0.8
15.5 ±
0.8
21 ± 1
21 ± 1
2080
766
2
1.5
1.6
0.7
2.3
0.4
40.7
2.3
43 ± 2
3060
1211
24
2
1.5
1.6
0.7
2.3
0.4
40.7
2.3
43 ± 2
3060
1211
1
1
3
3
1.5
1.5
1.6
1.6
0.7
0.7
1.1
1.1
0.2
0.2
4.5
4.5
1.2
1.2
290
290
93
93
2
3
1.5
1.6
0.7
1.1
0.3
11.9
1.5
560
213
2
3
1.5
1.6
0.7
1.1
0.3
11.9
1.5
560
213
4
3
1.5
1.6
0.7
1.1
0.3
15.3
1.6
13 ± 0.8
13 ± 0.8
18.5 ±
0.8
18.5 ±
0.8
21.5 ± 1
820
342
Subject to change without prior notice
36.5 ±
1.5
36.5 ±
1.5
9.5 ± 0.5
9.5 ± 0.5
14.5 ±
0.8
14.5 ±
0.8
17 ± 0.8
Page 120 of 212
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
4
8
8
3
3
3
1.5
1.5
1.5
1.6
1.6
1.6
0.7
0.7
0.7
1.1
1.1
1.1
16
3
1.5
1.6
0.9
2.3
16
3
1.5
1.6
0.9
2.3
24
24
3
3
1.5
1.5
1.6
1.6
0.9
0.9
2.7
2.7
1
1
2
2
2.5
2.5
2
2
0.7
0.7
1.1
1.1
2
2
2.5
2
0.7
1.1
4
8
2
2
2.5
2.5
2
2
0.7
0.7
1.1
1.1
16
2
2.5
2
0.9
2.3
1
3
2.5
2
0.7
1.1
8
3
2.5
2
0.7
12
3
2.5
2
0.7
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
17 ± 0.8 0.3
15.3
22.5 ± 1 0.3
20.4
22.5 ± 1 0.3
20.4
36.5 ±
0.4
36.2
1.5
36.5 ±
0.4
36.2
1.5
45.5 ± 2 0.4
45.2
45.5 ± 2 0.4
45.2
9.5 ± 0.5
9.5 ± 0.5
14.5 ±
0.8
17 ± 0.8
23.5 ± 1
36.5 ±
1.5
0.2
0.2
4.5
4.5
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
1.6
1.8
1.8
21.5 ± 1
27.5 ± 1
27.5 ± 1
820
1380
1380
342
584
584
2.2
42.5 ± 2
3040
1125
2.2
42.5 ± 2
3040
1125
2.5
2.5
52 ± 2.5
52 ± 2.5
4370
4370
1598
1598
1.2
1.2
300
300
99
99
560
225
830
1390
367
633
3020
1222
350
129
1820
844
2930
1284
0.3
11.9
1.5
0.3
0.3
15.3
20.4
1.6
1.8
13 ± 0.8
13 ± 0.8
18.5 ±
0.8
21.5 ± 1
28 ± 1
0.4
36.2
2.2
42.5 ± 2
10.5 ±
0.8
0.2
5.3
1.2
1.3
25.5 ± 1
0.3
22.9
2
2.6
33.5 ±
1.5
0.4
36.2
2.2
13.5 ±
0.8
30.5 ±
1.5
39.5 ±
1.5
Electrical values instrumentation cables
Type
Capacitance, approx.
(nF/km)
Inductance, approx,
(mH/km)
Resistance at 20°C, max.
(Ohm/km)
L/R ratio,
(microH/Ohm)
Shielded pair 0,75 mm²
Shielded triple 0,75 mm²
Shielded pair 1,5 mm²
Shielded triple 1,5 mm²
Shielded pair 2,5 mm²
Shielded triple 2,5 mm²
Shielded 16 and 24 triple 1,5 mm²
Shielded 16 pair 2,5 mm²
110
110
125
125
145
145
105
110
0,67
0,67
0,63
0,63
0,59
0,59
0,71
0,66
26,3
26,3
12,9
12,9
8,02
8,02
12,9
8,02
12,7
12,7
24,4
24,4
36,8
36,8
24,4
41,1
Ordering information
New Part
number
Old Part
number
20110770
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
813201
813206
813207
813218
813219
813230
813231
813242
813243
813248
813249
BFOU(I) 1PAIR 0.75mm² S3/S7 Cold
BFOU(I) 1PAIR 0.75mm² S3/S7 Cold
BFOU(I) 2PAIR 0.75mm² S3/S7 Cold
BFOU(I) 2PAIR 0.75mm² S3/S7 Cold
BFOU(I) 4PAIR 0.75mm² S3/S7 Cold
BFOU(I) 4PAIR 0.75mm² S3/S7 Cold
BFOU(I) 8PAIR 0.75mm² S3/S7 Cold
BFOU(I) 8PAIR 0.75mm² S3/S7 Cold
BFOU(I) 16PAIR 0.75mm² S3/S7 Cold
BFOU(I) 16PAIR 0.75mm² S3/S7 Cold
BFOU(I) 24PAIR 0.75mm² S3/S7 Cold
BFOU(I) 24PAIR 0.75mm² S3/S7 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528132007
7021528132014
7021528132069
7021528132076
7021528132182
7021528132199
7021528132304
7021528132311
7021528132427
7021528132434
7021528132489
7021528132496
-
813260
813261
813266
813267
813278
813279
813290
813291
813302
813308
813309
BFOU(I) 1TRIP 0.75mm² S3/S7 Cold
BFOU(I) 1TRIP 0.75mm² S3/S7 Cold
BFOU(I) 2TRIP 0.75mm² S3/S7 Cold
BFOU(I) 2TRIP 0.75mm² S3/S7 Cold
BFOU(I) 4TRIP 0.75mm² S3/S7 Cold
BFOU(I) 4TRIP 0.75mm² S3/S7 Cold
BFOU(I) 8TRIP 0.75mm² S3/S7 Cold
BFOU(I) 8TRIP 0.75mm² S3/S7 Cold
BFOU(I) 16TRIP 0.75mm² S3/S7 Cold
BFOU(I) 24TRIP 0.75mm² S3/S7 Cold
BFOU(I) 24TRIP 0.75mm² S3/S7 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
-
7021528132601
7021528132618
7021528132663
7021528132670
7021528132786
7021528132793
7021528132908
7021528132915
7021528133028
7021528133080
7021528133097
-
Subject to change without prior notice
Page 121 of 212
New Part
number
20113810
20126333
20110771
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
813407
813418
813419
813430
813431
813436
813442
813443
813448
813449
BFOU(I) 1PAIR 1.5mm² S3/S7 Cold
BFOU(I) 1PAIR 1.5mm² S3/S7 Cold
BFOU(I) 2PAIR 1.5mm² S3/S7 Cold
BFOU(I) 2PAIR 1.5mm² S3/S7 Cold
BFOU(I) 4PAIR 1.5mm² S3/S7 Cold
BFOU(I) 4PAIR 1.5mm² S3/S7 Cold
BFOU(I) 8PAIR 1.5mm² S3/S7 Cold
BFOU(I) 8PAIR 1.5mm² S3/S7 Cold
BFOU(I) 12PAIR 1.5mm² S3/S7 Cold
BFOU(I) 16PAIR 1.5mm² S3/S7 Cold
BFOU(I) 16PAIR 1.5mm² S3/S7 Cold
BFOU(I) 24PAIR 1.5mm² S3/S7 Cold
BFOU(I) 24PAIR 1.5mm² S3/S7 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
Yes
-
7021528134001
7021528134018
7021528134063
7021528134070
7021528134186
7021528134193
7021528134308
7021528134315
7021528134360
7021528134421
7021528134438
7021528134483
7021528134490
-
813461
813466
813467
813478
813479
813490
813491
813502
813503
813508
813509
BFOU(I) 1TRIP 1.5mm² S3/S7 Cold
BFOU(I) 1TRIP 1.5mm² S3/S7 Cold
BFOU(I) 2TRIP 1.5mm² S3/S7 Cold
BFOU(I) 2TRIP 1.5mm² S3/S7 Cold
BFOU(I) 4TRIP 1.5mm² S3/S7 Cold
BFOU(I) 4TRIP 1.5mm² S3/S7 Cold
BFOU(I) 8TRIP 1.5mm² S3/S7 Cold
BFOU(I) 8TRIP 1.5mm² S3/S7 Cold
BFOU(I) 16TRIP 1.5mm² S3/S7 Cold
BFOU(I) 16TRIP 1.5mm² S3/S7 Cold
BFOU(I) 24TRIP 1.5mm² S3/S7 Cold
BFOU(I) 24TRIP 1.5mm² S3/S7 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528134605
7021528134612
7021528134667
7021528134674
7021528134780
7021528134797
7021528134902
7021528134919
7021528135022
7021528135039
7021528135084
7021528135091
-
813600
813601
813606
813618
813630
813642
BFOU(I) 1PAIR 2.5mm² S3/S7 Cold
BFOU(I) 1PAIR 2.5mm² S3/S7 Cold
BFOU(I) 2PAIR 2.5mm² S3/S7 Cold
BFOU(I) 4PAIR 2.5mm² S3/S7 Cold
BFOU(I) 8PAIR 2.5mm² S3/S7 Cold
BFOU(I) 16PAIR 2.5mm² S3/S7 Cold
GREY
BLUE
GREY
GREY
GREY
GREY
-
7021528136005
7021528136012
7021528136067
7021528136180
7021528136302
7021528136425
-
813660
813690
813696
BFOU(I) 1TRIP 2.5mm² S3/S7 Cold
BFOU(I) 8TRIP 2.5mm² S3/S7 Cold
BFOU(I) 12TRIP 2.5mm² S3/S7 Cold
GREY
GREY
GREY
-
7021528136609
7021528136906
7021528136968
-
20126334
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-40°C
Page 122 of 212
ARCTIC GRADE Fire resistant, instrumentation cable BFOU(c) 150/250(300)V, S4/S8
Fire resistant, flame retardant halogen-free
instrumentation cable. Oil & Mud resistant.
Cold bend / Cold impact resistant
BFOU(c) 150/250(300)V
MGT/EPR/EPR/TCWB/EVA
NEK TS 606 CodeS4/S8 Arctic Grade
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation,
communication, control and alarm systems in both
EX- and safe areas, emergency and critical
systems where requirement for fire resistance
exists. Meets the OIL & MUD resistance
requirement in NEK TS 606:2009. Meets the cold
bend / cold impact requirement in CSA 22.2 0.3-01
and IEC 60092-350 Clause 8.9 & Annex E at 40°C/-35°C.
IEC 60092-376 (2003-05)
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-1, -2, -21
IEC 60754-1,2
IEC 61034-1,2
CSA 22.2 0.3-01 (-40°C/-35°C) /
IEC 60092-350 Annex E (-40°C/35°C)
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
- Cold Bend / Cold
Impact
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned annealed copper wire braid
Rubberized Polyamide tape
U
Flame retardant, halogen-free, mud and cold bend / cold impact resistant
thermoset compound, SHF2 (IEC 60092-360)
Eg. "meter" "year" DRAKA 01 BFOU(C) 250V S4/S8 4PAIR 0.75mm2 FLEX FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21 IEC 603323-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C)
DRAKA 01 = Draka Norsk Kabel
Marking text
Manufacturing
unit
Outer sheath
colour
Grey or Blue
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
Subject to change without prior notice
Page 123 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
2
2
0.75
1.1
0.6
1.1
2
2
0.75
1.1
0.6
1.1
4
2
0.75
1.1
0.6
1.1
4
2
0.75
1.1
0.6
1.1
8
2
0.75
1.1
0.6
1.1
8
2
0.75
1.1
0.6
1.1
16
16
2
2
0.75
0.75
1.1
1.1
0.6
0.6
24
2
0.75
1.1
24
2
0.75
2
2
4
4
3
3
3
3
8
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
340
113
340
113
0.3
13.6
1.5
20.5 ± 1
680
240
1.9
1.9
10.5 ±
0.8
10.5 ±
0.8
12.5 ±
0.8
12.5 ±
0.8
16.5 ±
0.8
16.5 ±
0.8
22 ± 1
22 ± 1
0.3
0.3
17.8
17.8
1.7
1.7
1180
1180
383
383
0.6
2.3
27.5 ± 1
0.3
22.9
2
1700
536
1.1
0.6
2.3
27.5 ± 1
0.3
22.9
2
27 ± 1
27 ± 1
32.5 ±
1.5
32.5 ±
1.5
1700
536
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
0.6
0.6
0.6
0.6
1.1
1.1
1.1
1.1
0.3
0.3
0.3
0.3
10.2
10.2
11.9
11.9
1.3
1.3
1.4
1.4
16 ± 0.8
16 ± 0.8
18 ± 0.8
18 ± 0.8
400
400
550
550
143
143
198
198
3
0.75
1.1
0.6
1.1
0.3
15.3
1.6
23 ± 1
870
308
8
3
0.75
1.1
0.6
1.1
12 ± 0.8
12 ± 0.8
14 ± 0.8
14 ± 0.8
18.5 ±
0.8
18.5 ±
0.8
0.3
15.3
1.6
23 ± 1
870
308
16
3
0.75
1.1
0.6
2.1
25.5 ± 1
0.3
20.4
1.8
1560
513
16
3
0.75
1.1
0.6
2.1
25.5 ± 1
0.3
20.4
1.8
1560
513
31.5 ±
1.5
0.4
36.2
2.1
2350
822
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
10.2
10.2
11.9
11.9
17.8
17.8
20.4
22.9
22.9
1.4
1.4
1.4
1.4
1.7
1.7
1.8
1.9
1.9
450
450
600
600
990
990
1350
1740
1740
162
162
234
234
404
404
540
677
677
0.4
36.2
2.2
2610
1030
0.4
36.2
2.2
2610
1030
0.3
11.9
1.4
540
207
540
207
760
760
1270
1270
307
307
517
517
1760
736
2540
1034
24
3
0.75
1.1
0.6
2.5
2
2
4
4
8
8
12
16
16
2
2
2
2
2
2
2
2
2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.1
1.1
1.1
1.1
1.1
1.1
1.4
1.9
1.9
24
2
1.5
1.6
0.7
2.3
24
2
1.5
1.6
0.7
2.3
2
3
1.5
1.6
0.7
1.1
2
3
1.5
1.6
0.7
1.1
4
4
8
8
3
3
3
3
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
0.7
0.7
0.7
0.7
12
3
1.5
1.6
16
3
1.5
16
3
24
3
13 ± 0.8
13 ± 0.8
15 ± 0.8
15 ± 0.8
20 ± 1
20 ± 1
24 ± 1
27 ± 1
27 ± 1
33.5 ±
1.5
33.5 ±
1.5
8.5
1.3
0.3
8.5
1.3
0.3
10.2
1.3
16 ± 0.8
440
155
0.3
10.2
1.3
16 ± 0.8
440
155
0.3
13.6
1.5
20.5 ± 1
680
240
0.3
11.9
1.4
1.1
1.1
1.1
1.1
14.5 ±
0.8
14.5 ±
0.8
17 ± 0.8
17 ± 0.8
22.5 ± 1
22.5 ± 1
0.3
0.3
0.3
0.3
13.6
13.6
17.8
17.8
1.5
1.5
1.8
1.8
0.7
1.4
27 ± 1
0.3
22.9
1.9
1.6
0.7
2.3
0.4
36.2
2.1
1.5
1.6
0.7
2.3
1.5
1.6
0.7
2.7
Subject to change without prior notice
31.5 ±
1.5
31.5 ±
1.5
38.5 ±
14.5 ±
0.8
14.5 ±
0.8
0.3
0.4
36.2
2.1
0.4
40.7
2.4
30.5 ±
1.5
30.5 ±
1.5
37.5 ±
1.5
17 ± 0.8
17 ± 0.8
19 ± 0.8
19 ± 0.8
25 ± 1
25 ± 1
29 ± 1
32 ± 1.5
32 ± 1.5
39.5 ±
1.5
39.5 ±
1.5
18.5 ±
0.8
18.5 ±
0.8
21 ± 1
21 ± 1
27.5 ± 1
27.5 ± 1
32.5 ±
1.5
37.5 ±
1.5
37.5 ±
1.5
45 ± 2
2540
1034
3560
1421
Page 124 of 212
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
2
2
2.5
2
0.7
1.1
4
2
2.5
2
0.7
1.1
8
16
24
2
2
2
2.5
2.5
2.5
2
2
2
0.7
0.9
0.9
1.1
2.3
2.7
8
3
2.5
2
0.7
1.1
16
3
2.5
2
0.9
2.6
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
1.5
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
14 ± 0.8
16.5 ±
0.8
22 ± 1
33 ± 1.5
41 ± 2
0.3
11.9
1.4
18 ± 0.8
530
217
0.3
13.6
1.5
20.5 ± 1
740
325
0.3
0.4
0.4
17.8
31.7
40.7
1.8
2.1
2.4
27 ± 1
39 ± 1.5
47.5 ± 2
1230
2590
3760
551
1054
1511
25 ± 1
38.5 ±
1.5
0.3
20.4
1.9
30 ± 1.5
1620
762
0.4
36.2
2.3
44.5 ± 2
3550
1473
Electrical values instrumentation cables
Type
Unshielded pair 0,75 mm²
Unshielded triple 0,75 mm²
Unshielded pair 1,5 mm²
Unshielded triple 1,5 mm²
Unshielded pair 2,5 mm²
Unshielded triple 2,5 mm²
Unshielded 16 and 24
pair 2,5 mm²
Unshielded 12, 16 and
24 triple 2,5 mm²
Capacitance, approx. Inductance, approx,
(nF/km)
(mH/km)
100
0,67
100
0,67
110
0,63
110
0,63
125
0,59
125
0,59
Resistance at 20°C, max.
(Ohm/km)
26,3
26,3
12,9
12,9
8,02
8,02
L/R ratio,
(microH/Ohm)
12,7
12,7
24,4
24,4
36,8
36,8
95
0,66
8,02
36,8
95
0,66
8,02
36,8
Ordering information
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
813806
813807
813818
813819
813830
813831
813842
813843
813848
813849
BFOU(C) 2PAIR 0.75mm² S4/S8 Cold
BFOU(C) 2PAIR 0.75mm² S4/S8 Cold
BFOU(C) 4PAIR 0.75mm² S4/S8 Cold
BFOU(C) 4PAIR 0.75mm² S4/S8 Cold
BFOU(C) 8PAIR 0.75mm² S4/S8 Cold
BFOU(C) 8PAIR 0.75mm² S4/S8 Cold
BFOU(C) 16PAIR 0.75mm² S4/S8 Cold
BFOU(C) 16PAIR 0.75mm² S4/S8 Cold
BFOU(C) 24PAIR 0.75mm² S4/S8 Cold
BFOU(C) 24PAIR 0.75mm² S4/S8 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528138061
7021528138078
7021528138184
7021528138191
7021528138306
7021528138313
7021528138429
7021528138436
7021528138481
7021528138498
-
813866
813867
813878
813879
813890
813891
813902
813903
813908
BFOU(C) 2TRIP 0.75mm² S4/S8 Cold
BFOU(C) 2TRIP 0.75mm² S4/S8 Cold
BFOU(C) 4TRIP 0.75mm² S4/S8 Cold
BFOU(C) 4TRIP 0.75mm² S4/S8 Cold
BFOU(C) 8TRIP 0.75mm² S4/S8 Cold
BFOU(C) 8TRIP 0.75mm² S4/S8 Cold
BFOU(C) 16TRIP 0.75mm² S4/S8 Cold
BFOU(C) 16TRIP 0.75mm² S4/S8 Cold
BFOU(C) 24TRIP 0.75mm² S4/S8 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
-
7021528138665
7021528138672
7021528138788
7021528138795
7021528138900
7021528138917
7021528139020
7021528139037
7021528139082
-
814006
814007
814018
814019
814031
814036
814042
814043
814048
814049
BFOU(C) 2PAIR 1.5mm² S4/S8 Cold
BFOU(C) 2PAIR 1.5mm² S4/S8 Cold
BFOU(C) 4PAIR 1.5mm² S4/S8 Cold
BFOU(C) 4PAIR 1.5mm² S4/S8 Cold
BFOU(C) 8PAIR 1.5mm² S4/S8 Cold
BFOU(C) 8PAIR 1.5mm² S4/S8 Cold
BFOU(C) 12PAIR 1.5mm² S4/S8 Cold
BFOU(C) 16PAIR 1.5mm² S4/S8 Cold
BFOU(C) 16PAIR 1.5mm² S4/S8 Cold
BFOU(C) 24PAIR 1.5mm² S4/S8 Cold
BFOU(C) 24PAIR 1.5mm² S4/S8 Cold
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
Yes
-
7021528140064
7021528140071
7021528140187
7021528140194
7021528140309
7021528140316
7021528140361
7021528140422
7021528140439
7021528140484
7021528140491
-
814066
814067
814078
BFOU(C) 2TRIP 1.5mm² S4/S8 Cold
BFOU(C) 2TRIP 1.5mm² S4/S8 Cold
BFOU(C) 4TRIP 1.5mm² S4/S8 Cold
GREY
BLUE
GREY
-
7021528140668
7021528140675
7021528140781
-
20116213
Subject to change without prior notice
Page 125 of 212
New Part
number
Old Part
number
814079
814090
814091
814096
814102
814103
814108
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
BFOU(C) 4TRIP 1.5mm² S4/S8 Cold
BFOU(C) 8TRIP 1.5mm² S4/S8 Cold
BFOU(C) 8TRIP 1.5mm² S4/S8 Cold
BFOU(C) 12TRIP 1.5mm² S4/S8 Cold
BFOU(C) 16TRIP 1.5mm² S4/S8 Cold
BFOU(C) 16TRIP 1.5mm² S4/S8 Cold
BFOU(C) 24TRIP 1.5mm² S4/S8 Cold
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
-
7021528140798
7021528140903
7021528140910
7021528140965
7021528141023
7021528141030
7021528141085
-
814206
814218
814230
814242
814248
BFOU(C) 2PAIR 2.5mm² S4/S8 Cold
BFOU(C) 4PAIR 2.5mm² S4/S8 Cold
BFOU(C) 8PAIR 2.5mm² S4/S8 Cold
BFOU(C) 16PAIR 2.5mm² S4/S8 Cold
BFOU(C) 24PAIR 2.5mm² S4/S8 Cold
GREY
GREY
GREY
GREY
GREY
-
7021528142068
7021528142181
7021528142303
7021528142426
7021528142488
-
814290
814302
BFOU(C) 8TRIP 2.5mm² S4/S8 Cold
BFOU(C) 16TRIP 2.5mm² S4/S8 Cold
GREY
GREY
-
7021528142907
7021528143027
-
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-40°C
Page 126 of 212
ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8
Flame retardant halogen-free power
cable. Oil & Mud resistant. Cold bend /
Cold impact resistant
RFOU 0,6/1(1,2)kV
EPR/EPR/TCWB/EVA
NEK TS 606 CodeP1/P8 Arctic Grade
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
IEC 60092-353
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
Application
- Design
- Conductor
- Insulation
- Sheath
- Flame
Retardant
- Flame
Retardant
- Halogen Free
- Low Smoke
Fixed installation for power,control and lighting in both EXand safe areas, general purposes. For installation in areas IEC 60332-1-2
exposed to MUD and drilling/cleaning fluids. Meets the OIL
& MUD resistance requirement in NEK 606. Meets the cold IEC 60332-3-22
bend / cold impact requirement in CSA 22.2 0.3-01 and IEC
IEC 60754-1,2
60092-350 clause 8.9 & Annex E at -40°C / -35°C.
IEC 61034-1,2
CSA 22.2 0.3-01 (-40°C/-35°C)
- Cold Bend /
/ IEC 60092-352 Annex E
Cold Impact
(-40°C/-35°C)
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
R
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
Rubberized Polyamide tape
U
Flame retardant, halogen-free, mud and cold bend / cold impact resistant
thermoset compound, SHF2 (IEC 60092-359)
E.g. "meter" "year" DRAKA 01 RFOU 0.6/1kV P1/P8 3 x 95/50mm2 IEC 603323-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C)
DRAKA 01 = Draka Norsk Kabel,
Black
Marking text
Manufacturing unit
Outer sheath
colour
Subject to change without prior notice
Page 127 of 212
Core identification power cables
Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445: Edition 5.0 2010-08 -
Range and dimensions
Cross
Number
section
of
core,
elements
mm²
Electrical
Thickness
Conductor Insulation
Cross
Inner
Diameter, Thickness,
section
covering,
mm
mm
braid, mm²
mm
Diameter
inner
covering,
mm
Thickness
Diameter
Outer
Braid
Sheath,
Wire, mm
mm
Diameter
outer
sheath,
mm
Weight of
Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
1
1
1
1
1
1
1
1
1
1
1
16
25
35
50
70
95
120
150
185
240
300
2.5
4
6
6
10
10
10
10
10
16
16
5.15
6.45
7.65
9.0
10.85
12.60
14.20
15.90
17.70
20.15
22.60
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.1
1.1
1.1
1.1
1.1
1.1
1.2
1.2
1.2
1.2
1.2
9.5 ± 0.5
11.5 ± 0.8
12.5 ± 0.8
14.5 ± 0.8
16.5 ± 0.8
18.5 ± 0.8
20.5 ± 1
22.5 ± 1
24.5 ± 1
27.5 ± 1
30.5 ± 1.5
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
1.2
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
13 ± 0.8
15 ± 0.8
16.5 ± 0.8
18.5 ± 0.8
21 ± 1
23 ± 1
25 ± 1
27 ± 1
29.5 ± 1
33 ± 1.5
35.5 ± 1.5
370
490
660
840
1120
1400
1730
2070
2490
3140
3830
190
283
413
534
757
973
1231
1507
1838
2365
2959
2
3
4
5
7
12
19
27
37
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
4
4
6
6
6
10
10
10
16
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.1
1.1
1.1
1.2
1.2
1.2
9.5 ± 0.5
10 ± 0.8
11 ± 0.8
12 ± 0.8
12 ± 0.8
16 ± 0.8
19 ± 0.8
22.5 ± 1
25 ± 1
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
1.2
1.3
1.3
1.3
1.5
1.6
1.8
1.9
13 ± 0.8
13.5 ± 0.8
15 ± 0.8
16 ± 0.8
16 ± 0.8
20 ± 1
23.5 ± 1
27.5 ± 1
30.5 ± 1.5
275
300
380
450
490
720
1000
1320
1680
80
94
139
170
198
301
415
550
716
2
3
4
5
7
12
19
27
37
3G
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
6
6
6
6
10
10
16
16
-
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.1
1.1
1.2
1.2
1.2
1.4
1.1
10.5 ± 0.8
11 ± 0.8
12 ± 0.8
13.5 ± 0.8
13.5 ± 0.8
18 ± 0.8
21 ± 1
25 ± 1
29 ± 1
11 ± 0.8
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
1.3
1.3
1.4
1.4
1.6
1.7
1.9
2
1.3
14 ± 0.8
15 ± 0.8
16 ± 0.8
17.5 ± 0.8
17.5 ± 0.8
22.5 ± 1
26 ± 1
30.5 ± 1.5
34 ± 1.5
15 ± 0.8
320
400
470
540
620
930
1290
1720
2240
400
98
152
192
214
277
426
611
819
1074
152
2
3
4
5
3G
4G
12
20
4
4
4
4
4
4
4
4
6
6
6
6
10
16
2.55
2.55
2.55
2.55
2.55
2.55
2.55
2.55
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.1
1.1
1.1
1.2
1.2
11.5 ± 0.8
12 ± 0.8
13.5 ± 0.8
14.5 ± 0.8
12 ± 0.8
13.5 ± 0.8
20 ± 1
25 ± 1
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.3
1.3
1.4
1.4
1.3
1.4
1.7
1.9
15.5 ± 0.8
16 ± 0.8
17.5 ± 0.8
19 ± 0.8
16 ± 0.8
17.5 ± 0.8
24.5 ± 1
30.5 ± 1.5
420
490
570
670
490
570
1200
1830
157
210
247
300
210
247
616
935
2
3
4
3G
4G
5G
6
6
6
6
6
6
6
6
6
-
3.15
3.15
3.15
3.15
3.15
3.15
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.1
1.1
1.1
12.5 ± 0.8
13.5 ± 0.8
15 ± 0.8
13.5 ± 0.8
15 ± 0.8
16.5 ± 0.8
0.3
0.3
0.3
0.3
0.3
0.3
1.3
1.4
1.4
1.4
1.4
1.5
16.5 ± 0.8
17.5 ± 0.8
19 ± 0.8
17.5 ± 0.8
19 ± 0.8
20.5 ± 1
510
590
700
590
700
820
209
264
335
264
335
390
2
3
10
10
10
10
4.05
4.05
1.0
1.0
1.1
1.1
14.5 ± 0.8 0.3
15.5 ± 0.8 0.3
1.4
1.4
18.5 ± 0.8 670
19.5 ± 0.8 790
300
391
Subject to change without prior notice
Page 128 of 212
Cross
Number
section
of
core,
elements
mm²
4
10
4G
10
5G
10
Electrical
Cross
section
braid, mm²
10
-
Thickness
Conductor Insulation
Inner
Diameter, Thickness,
covering,
mm
mm
mm
4.05
1.0
1.1
4.05
1.0
1.1
4.05
1.0
1.2
Diameter
inner
covering,
mm
17 ± 0.8
17 ± 0.8
19 ± 0.8
Thickness
Diameter
Outer
Braid
Sheath,
Wire, mm
mm
0.3
1.5
0.3
1.5
0.3
1.5
Diameter
outer
sheath,
mm
21.5 ± 1
21.5 ± 1
23 ± 1
Weight of
Cable
Approx.
(Kg/Km)
950
950
1140
Copper
content
Approx.
(kg/km)
496
496
603
2
3
4
3G
4G
5G
16
16
16
16
16
16
16
16
16
-
5.15
5.15
5.15
5.15
5.15
5.15
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.2
1.1
1.2
1.2
16.5 ± 0.8
18 ± 0.8
20 ± 1
18 ± 0.8
20 ± 1
22 ± 1
0.4
0.4
0.4
0.3
0.3
0.3
1.5
1.5
1.6
1.5
1.6
1.6
21.5 ± 1
22.5 ± 1
24.5 ± 1
22 ± 1
24.5 ± 1
26.5 ± 1
950
1120
1400
1060
1320
1570
481
626
806
571
734
905
2
3
4
4G
5G
25
25
25
25
25
16
16
16
-
6.45
6.45
6.45
6.45
6.45
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
20.5 ± 1
22 ± 1
24.5 ± 1
24.5 ± 1
27 ± 1
0.4
0.3
0.3
0.3
0.3
1.6
1.6
1.7
1.7
1.8
25.5 ± 1
26.5 ± 1
29 ± 1
29 ± 1
31.5 ± 1.5
1340
1570
1920
1890
2270
685
893
1125
1100
1356
2
3
4
4G
5G
35
35
35
35
35
16
16
16
-
7.65
7.65
7.65
7.65
7.65
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
23 ± 1
24.5 ± 1
27 ± 1
27 ± 1
30 ± 1.5
0.3
0.3
0.3
0.3
0.3
1.7
1.7
1.8
1.8
1.9
27.5 ± 1
29 ± 1
32 ± 1.5
32 ± 1.5
35 ± 1.5
1600
1940
2390
2390
2860
828
1142
1456
1456
1795
3
4
4G
5G
50
50
50
50
25
25
-
9.0
9.0
9.0
9.0
1.4
1.4
1.4
1.4
1.2
1.4
1.4
1.4
28.5 ± 1
32 ± 1.5
32 ± 1.5
35 ± 1.5
0.4
0.4
0.3
0.4
1.9
2
2
2.1
34 ± 1.5
37.5 ± 1.5
37.5 ± 1.5
41 ± 2
2690
3310
3230
4010
1617
2052
1970
2531
2
3
4
4G
70
70
70
70
35
35
35
-
10.85
10.85
10.85
10.85
1.4
1.4
1.4
1.4
1.2
1.4
1.4
1.4
30.5 ± 1.5
33 ± 1.5
36.5 ± 1.5
36.5 ± 1.5
0.6
0.5
0.5
0.4
1.9
2
2.2
2.2
36.5 ± 1.5
39 ± 1.5
43 ± 2
42.5 ± 2
3040
3720
4580
4450
1782
2385
3018
2888
2
3
4
4G
95
95
95
95
50
50
50
-
12.60
12.60
12.60
12.60
1.6
1.6
1.6
1.6
1.4
1.4
1.4
1.4
35 ± 1.5
37.5 ± 1.5
41.5 ± 2
41.5 ± 2
0.6
0.5
0.5
0.4
2.1
2.2
2.4
2.4
41.5 ± 2
43.5 ± 2
48.5 ± 2
48 ± 2
3940
4810
6000
5770
2317
3126
4020
3796
2
3
4
120
120
120
60
60
60
14.20
14.20
14.20
1.6
1.6
1.6
1.4
1.4
1.6
38 ± 1.5
41 ± 2
46 ± 2
0.6
0.6
0.6
2.2
2.3
2.5
45 ± 2
4790
48 ± 2
5930
53.5 ± 2.5 7420
2891
3975
5100
Ordering information
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
810000
810001
810002
810003
810004
810005
810006
810007
810008
810009
810010
RFOU 0.6/1kV 1X16/2.5 P1/P8 Cold
RFOU 0.6/1kV 1X25/4 P1/P8 Cold
RFOU 0.6/1kV 1X35/6 P1/P8 Cold
RFOU 0.6/1kV 1X50/6 P1/P8 Cold
RFOU 0.6/1kV 1X70/10 P1/P8 Cold
RFOU 0.6/1kV 1X95/10 P1/P8 Cold
RFOU 0.6/1kV 1X120/10 P1/P8 Cold
RFOU 0.6/1kV 1X150/10 P1/P8 Cold
RFOU 0.6/1kV 1X185/10 P1/P8 Cold
RFOU 0.6/1kV 1X240/16 P1/P8 Cold
RFOU 0.6/1kV 1X300/16 P1/P8 Cold
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528100006
7021528100013
7021528100020
7021528100037
7021528100044
7021528100051
7021528100068
7021528100075
7021528100082
7021528100099
7021528100105
-
810015
810018
810019
810020
810021
810022
810023
810024
810025
RFOU 0.6/1kV 2X1.5/4 P1/P8 Cold
RFOU 0.6/1kV 3X1.5/4 P1/P8 Cold
RFOU 0.6/1kV 4X1.5/6 P1/P8 Cold
RFOU 0.6/1kV 5X1.5/6 P1/P8 Cold
RFOU 0.6/1kV 7X1.5/6 P1/P8 Cold
RFOU 0.6/1kV 12X1.5/10 P1/P8 Cold
RFOU 0.6/1kV 19X1.5/10 P1/P8 Cold
RFOU 0.6/1kV 27X1.5/10 P1/P8 Cold
RFOU 0.6/1kV 37X1.5/16 P1/P8 Cold
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528100150
7021528100181
7021528100198
7021528100204
7021528100211
7021528100228
7021528100235
7021528100242
7021528100259
-
Subject to change without prior notice
Page 129 of 212
New Part
number
Old Part
number
810029
810032
810035
810036
810037
810038
810039
810040
810041
Tba
Description
RFOU 0.6/1kV 2X2.5/4 P1/P8 Cold
RFOU 0.6/1kV 3X2.5/6 P1/P8 Cold
RFOU 0.6/1kV 4X2.5/6 P1/P8 Cold
RFOU 0.6/1kV 5X2.5/6 P1/P8 Cold
RFOU 0.6/1kV 7X2.5/6 P1/P8 Cold
RFOU 0.6/1kV 12X2.5/10 P1/P8 Cold
RFOU 0.6/1kV 19X2.5/10 P1/P8 Cold
RFOU 0.6/1kV 27X2.5/16 P1/P8 Cold
RFOU 0.6/1kV 37X2.5/16 P1/P8 Cold
RFOU 0.6/1kV 3G 2.5 P1/P8 Cold
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528100297
7021528100327
7021528100358
7021528100365
7021528100372
7021528100389
7021528100396
7021528100402
7021528100419
-
-
810045
810046
810047
810048
Tba
Tba
810150
810151
RFOU 0.6/1kV 2X 4/6 P1/P8 Cold
RFOU 0.6/1kV 3X 4/6 P1/P8 Cold
RFOU 0.6/1kV 4X 4/6 P1/P8 Cold
RFOU 0.6/1kV 5X 4/6 P1/P8 Cold
RFOU 0.6/1kV 3G 4 P1/P8 Cold
RFOU 0.6/1kV 4G 4 P1/P8 Cold
RFOU 0.6/1kV 12X4/10 P1/P8 Cold
RFOU 0.6/1kV 20X4/16 P1/P8 Cold
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528100457
7021528100464
7021528100471
7021528100488
7021528101508
7021528101515
-
810051
810052
810053
Tba
Tba
810056
RFOU 0.6/1kV 2X 6/6 P1/P8 Cold
RFOU 0.6/1kV 3X 6/6 P1/P8 Cold
RFOU 0.6/1kV 4X 6/6 P1/P8 Cold
RFOU 0.6/1kV 3G 6 P1/P8 Cold
RFOU 0.6/1kV 4G 6 P1/P8 Cold
RFOU 0.6/1kV 5G 6 P1/P8 Cold
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528100518
7021528100525
7021528100532
7021528100563
-
810057
810058
810059
Tba
Tba
RFOU 0.6/1kV 2X10/10 P1/P8 Cold
RFOU 0.6/1kV 3X10/10 P1/P8 Cold
RFOU 0.6/1kV 4X10/10 P1/P8 Cold
RFOU 0.6/1kV 4G 10 P1/P8 Cold
RFOU 0.6/1kV 5G 10 P1/P8 Cold
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528100570
7021528100587
7021528100594
-
-
810063
810064
810065
Tba
Tba
810067
RFOU 0.6/1kV 2X16/16 P1/P8 Cold
RFOU 0.6/1kV 3X16/16 P1/P8 Cold
RFOU 0.6/1kV 4X16/16 P1/P8 Cold
RFOU 0.6/1kV 3G 16 P1/P8 Cold
RFOU 0.6/1kV 4G 16 P1/P8 Cold
RFOU 0.6/1kV 5G 16 P1/P8 Cold
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528100631
7021528100648
7021528100655
7021528100679
-
810069
810070
810071
Tba
810074
RFOU 0.6/1kV 2X25/16 P1/P8 Cold
RFOU 0.6/1kV 3X25/16 P1/P8 Cold
RFOU 0.6/1kV 4X25/16 P1/P8 Cold
RFOU 0.6/1kV 4G 25 P1/P8 Cold
RFOU 0.6/1kV 5G 25 P1/P8 Cold
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528100693
7021528100709
7021528100716
7021528100747
-
810075
810076
810077
Tba
810079
RFOU 0.6/1kV 2X35/16 P1/P8 Cold
RFOU 0.6/1kV 3X35/16 P1/P8 Cold
RFOU 0.6/1kV 4X35/16 P1/P8 Cold
RFOU 0.6/1kV 4G 35 P1/P8 Cold
RFOU 0.6/1kV 5G 35 P1/P8 Cold
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528100754
7021528100761
7021528100778
7021528100792
-
810082
810083
Tba
Tba
RFOU 0.6/1kV 3X50/25 P1/P8 Cold
RFOU 0.6/1kV 4X50/25 P1/P8 Cold
RFOU 0.6/1kV 4G 50 P1/P8 Cold
RFOU 0.6/1kV 5G 50 P1/P8 Cold
BLACK
BLACK
BLACK
BLACK
-
7021528100822
7021528100839
-
-
810087
810088
810089
RFOU 0.6/1kV 2X70/35 P1/P8 Cold
RFOU 0.6/1kV 3X70/35 P1/P8 Cold
RFOU 0.6/1kV 4X70/35 P1/P8 Cold
RFOU 0.6/1kV 4G 70 P1/P8 Cold
BLACK
BLACK
BLACK
BLACK
-
7021528100877
7021528100884
7021528100891
-
-
810094
810095
810096
RFOU 0.6/1kV 2X95/50 P1/P8 Cold
RFOU 0.6/1kV 3X95/50 P1/P8 Cold
RFOU 0.6/1kV 4X95/50 P1/P8 Cold
RFOU 0.6/1kV 4G 95 P1/P8 Cold
BLACK
BLACK
BLACK
BLACK
-
7021528100945
7021528100952
7021528100969
-
-
810100
810101
810105
RFOU 0.6/1kV 2X120/60 P1/P8 Cold
RFOU 0.6/1kV 3X120/60 P1/P8 Cold
RFOU 0.6/1kV 4X120/60 P1/P8 Cold
BLACK
BLACK
BLACK
-
7021528101003
7021528101010
7021528101058
-
Subject to change without prior notice
Sheath Colour
Stock item
EAN No. DNK
Page 130 of 212
EL No.
Electrical values power cables
Number of
elements
Cross
section
core,
mm²
Electrical
Cross
section
braid, mm²
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table
second,
B.4, Ampere
Ampere
1
1
1
1
1
1
1
1
1
1
1
16
25
35
50
70
95
120
150
185
240
300
2.5
4
6
6
10
10
10
10
10
16
16
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
1.16
0.734
0.529
0.391
0.27
0.195
0.154
0.126
0.1
0.0762
0.0607
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
0.118
0.111
0.108
0.105
0.100
0.097
0.095
0.093
0.092
0.090
0.088
0.142
0.134
0.129
0.126
0.120
0.117
0.114
0.112
0.110
0.108
0.105
96
127
157
196
242
293
339
389
444
522
601
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
2
3
4
5
7
12
19
27
37
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
4
4
6
6
6
10
10
10
16
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.132
0.132
0.132
0.132
0.132
0.132
0.132
0.132
0.132
20
16
16
13.5
12
10
8.5
7.5
7
210
210
210
210
210
210
210
210
210
2
3
4
5
7
12
19
27
37
3G
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
6
6
6
6
10
10
16
16
-
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.123
0.123
0.123
0.123
0.123
0.123
0.123
0.123
0.123
0.123
26
21
21
17.5
15.5
13
11
10
9
26
350
350
350
350
350
350
350
350
350
350
2
3
4
5
3G
4G
12
20
4
4
4
4
4
4
4
4
6
6
6
6
10
16
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
5.99
5.99
5.99
5.99
5.99
5.99
5.99
5.99
0.096
0.096
0.096
0.096
0.096
0.096
0.096
0.096
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
34
28
28
23.5
34
28
17.5
14.5
560
560
560
560
560
560
560
560
2
3
4
3G
4G
5G
6
6
6
6
6
6
6
6
6
-
STCC
STCC
STCC
STCC
STCC
STCC
3.11
3.11
3.11
3.11
3.11
3.11
3.97
3.97
3.97
3.97
3.97
3.97
0.090
0.090
0.090
0.090
0.090
0.090
0.108
0.108
0.108
0.108
0.108
0.108
44
36
36
44
36
36
840
840
840
840
840
840
2
3
4
4G
5G
10
10
10
10
10
10
10
10
-
STCC
STCC
STCC
STCC
STCC
1.84
1.84
1.84
1.84
1.84
2.35
2.35
2.35
2.35
2.35
0.084
0.084
0.084
0.084
0.084
0.101
0.101
0.101
0.101
0.101
61
50
50
50
50
1400
1400
1400
1400
1400
2
3
4
3G
4G
5G
16
16
16
16
16
16
16
16
16
-
STCC
STCC
STCC
STCC
STCC
STCC
1.16
1.16
1.16
1.16
1.16
1.16
1.48
1.48
1.48
1.48
1.48
1.48
0.080
0.080
0.080
0.080
0.080
0.080
0.096
0.096
0.096
0.096
0.096
0.096
80
67
67
80
67
67
2240
2240
2240
2240
2240
2240
2
3
4
4G
25
25
25
25
16
16
16
-
STCC
STCC
STCC
STCC
0.734
0.734
0.734
0.734
0.936
0.936
0.936
0.936
0.079
0.079
0.079
0.079
0.095
0.095
0.095
0.095
108
89
89
89
3500
3500
3500
3500
Subject to change without prior notice
Page 131 of 212
Number of
elements
5G
Cross
section
core,
mm²
25
Electrical
Cross
section
braid, mm²
-
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table
second,
B.4, Ampere
Ampere
STCC
0.734
0.936
0.079
0.095
89
3500
2
3
4
4G
5G
35
35
35
35
35
16
16
16
-
STCC
STCC
STCC
STCC
STCC
0.529
0.529
0.529
0.529
0.529
0.675
0.675
0.675
0.675
0.675
0.076
0.076
0.076
0.076
0.076
0.092
0.092
0.092
0.092
0.092
133
110
110
110
110
4900
4900
4900
4900
4900
3
4
4G
5G
50
50
50
50
25
25
-
STCC
STCC
STCC
STCC
0.391
0.391
0.391
0.391
0.499
0.499
0.499
0.499
0.076
0.076
0.076
0.076
0.092
0.092
0.092
0.092
137
137
137
137
7000
7000
7000
7000
2
3
4
4G
70
70
70
70
35
35
35
-
STCC
STCC
STCC
STCC
0.27
0.27
0.27
0.27
0.344
0.344
0.344
0.344
0.074
0.074
0.074
0.074
0.088
0.088
0.088
0.088
206
169
169
169
9800
9800
9800
9800
2
3
4
4G
95
95
95
95
50
50
50
-
STCC
STCC
STCC
STCC
0.195
0.195
0.195
0.195
0.249
0.249
0.249
0.249
0.073
0.073
0.073
0.073
0.088
0.088
0.088
0.088
249
205
205
205
13300
13300
13300
13300
2
3
4
120
120
120
60
60
60
STCC
STCC
STCC
0.154
0.154
0.154
0.196
0.196
0.196
0.072
0.072
0.072
0.086
0.086
0.086
288
237
237
16800
16800
16800
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-40°C
Page 132 of 212
ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8, large single core cables
Flame retardant halogen-free power
cable. Oil & Mud resistant. Cold
bend / Cold impact resistant. Single
core cable
RFOU 0,6/1(1,2)kV
EPR/EPR/TCWB/EVA
NEK TS 606 CodeP1/P8 Arctic Grade
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
Fixed installation for power,control and lighting in both EX- and
safe areas, general purposes. For installation in areas exposed
to MUD and drilling/cleaning fluids. Meets the OIL & MUD
resistance requirement in NEK 606. Meets the cold bend / cold
impact requirement in CSA 22.2 0.3-01 and IEC 60092-350
clause 8.9 & Annex E at -40°C / -35°C.
IEC 60092-353
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
CSA 22.2 0.3-01 (-40°C/35°C) / IEC 60092-352
Annex E (-40°C/-35°C)
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke
- Cold Bend /
Cold Impact
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
R
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned annealed copper wire braid
Rubberized Polyamide tape
U
Flame retardant, halogen-free, mud and cold bend / cold impact resistant
thermoset compound, SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 01 RFOU 0.6/1kV P1/P8 1 x 400/25mm2 IEC
60092-353 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold
impact (-35 deg. C
DRAKA 01 = Draka Norsk Kabel,
Black
Marking text
Manufacturing unit
Outer sheath
colour
Subject to change without prior notice
Page 133 of 212
Core identification power cables
Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445: Edition 5.0 2010-08 -
Range and dimensions
Cross
Number
section
of
core,
elements
mm²
Electrical
Thickness
Conductor Insulation
Cross
Inner
Diameter, Thickness,
section
covering,
mm
mm
braid, mm²
mm
Diameter
inner
covering,
mm
1
25
34.5 ± 1.5 0.4
400
26.00
2.4
1.4
Thickness
Diameter
Outer
Braid
Sheath,
Wire, mm
mm
2.1
Diameter
outer
sheath,
mm
Weight of
Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
40.5 ± 2
5050
3970
Ordering information
New Part
number
Old Part
number
810011
Description
Sheath Colour
RFOU 0.6/1kV 1X400/25 P1/P8 Cold
BLACK
Stock item
-
EAN No. DNK
EL No.
7021528100112
-
Electrical values power cables
Number of
elements
1
Cross
section
core,
mm²
400
Electrical
Cross
section
braid, mm²
25
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table
second,
B.4, Ampere
Ampere
STCC
0.0475
0.0606
0.087
0.104
690 dc / 670
ac
56000
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-40°C
Page 134 of 212
ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8, double braided
Flame retardant halogen-free power
cable. Oil & Mud resistant. Cold bend /
Cold impact resistant. Double braided.
RFOU 0,6/1(1,2)kV
EPR/EPR/TCWB/EVA
NEK TS 606 CodeP1/P8
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
Fixed installation for power,control and lighting in both EXand safe areas, general purposes. For installation in areas
exposed to MUD and drilling/cleaning fluids. Meets the OIL
& MUD resistance requirement in NEK 606. Meets the cold
bend / cold impact requirement in CSA 22.2 0.3-01 and
IEC 60092-350 clause 8.9 & Annex E at -40°C / -35°C.
IEC 60092-353
- Design
IEC 60228 class 2
- Conductor
IEC 60092-360
- Insulation
IEC 60092-360
- Sheath
IEC 60332-1-2
- Flame Retardant
IEC 60332-3-22
- Flame Retardant
IEC 60754-1,2
- Halogen Free
IEC 61034-1,2
- Low Smoke
CSA 22.2 0.3-01 (-40°C/-35°C)
- Cold Bend /
/ IEC 60092-352 Annex E (Cold Impact
40°C/-35°C)
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
R
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoset compound
PET tape + rubberized Polyamide tape
O
Two layers of tinned copper wire braid (double braid)
PET tape + rubberized Polyamide tape
U
Flame retardant, halogen-free, mud and cold bend / cold impact resistant
thermoset compound, SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 01 RFOU 0,6/1kV P1/P8 3 x150/70 mm2 IEC
60092-353 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold
impact (-35 deg. C)
DRAKA 01 = Draka Norsk Kabel,
Black
Marking text
Manufacturing unit
Outer sheath
colour
Subject to change without prior notice
Page 135 of 212
Core identification power cables
Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445: Edition 5.0 2010-08 -
Range and dimensions
Cross
Number
section
of
core,
elements
mm²
Electrical
Thickness
Conductor Insulation
Cross
Inner
Diameter, Thickness,
section
covering,
mm
mm
braid, mm²
mm
Diameter
inner
covering,
mm
Thickness
Diameter
Outer
Braid
Sheath,
Wire, mm
mm
Diameter
outer
sheath,
mm
Weight of
Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
3
4
150
150
75
75
15.9
15.9
1.8
1.8
1.6
2
46 ± 2
0.4
51.5 ± 2.5 0.5
2.6
2.8
54 ± 2.5
61 ± 3
7440
9450
4981
6444
3
4
185
185
95
95
17.70
17.7
2.0
2.0
1.6
2
50.5 ± 2.5 0.5
57 ± 2.5
0.5
2.7
3
59.5 ± 2.5 9200
67 ± 3
11390
6283
7837
3
240
120
20.15
2.2
1.8
57.5 ± 2.5 0.6
3
68 ± 3
8046
11760
Ordering information
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
810102
810103
RFOU 0.6/1kV 3X150/75 P1/P8 Cold
RFOU 0.6/1kV 4X150/75 P1/P8 Cold
BLACK
BLACK
-
7021528101027
7021528101034
-
810106
810107
RFOU 0.6/1kV 3X185/95 P1/P8 Cold
RFOU 0.6/1kV 4X185/95 P1/P8 Cold
BLACK
BLACK
-
7021528101065
7021528101072
-
810112
RFOU 0.6/1kV 3X240/120 P1/P8 Cold
BLACK
-
7021528101126
-
Electrical values power cables
Number of
elements
Cross
section
core,
mm²
Electrical
Cross
section
braid, mm²
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table
second,
B.4, Ampere
Ampere
3
4
150
150
75
75
STCC
STCC
0.126
0.126
0.161
0.161
0.072
0.072
0.087
0.087
272
272
21000
21000
3
4
185
185
95
95
STCC
STCC
0.1
0.1
0.128
0.161
0.072
0.072
0.086
0.086
311
311
25900
25900
3
240
120
STCC
0.0762
0.0972
0.072
0.086
365
33600
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-40°C
Page 136 of 212
ARCTIC GRADE Fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12
Fire resistant, flame retardant halogenfree power cable. Oil & Mud resistant.
Cold bend / Cold impact resistant
BFOU 0,6/1(1,2)kV
MGT/EPR/EPR/TCWB/EVA
NEK TS 606 CodeP5/P12 Arctic Grade
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
Fixed installation for power, control and lighting in both EX
(Zone 0, 1 & 2)- and safe areas, emergency and critical
systems where requirement for fire resistance exists. For
installation in areas exposed to MUD and drilling/cleaning
fluids. Meets the OIL & MUD resistance requirement in
NEK 606. Meets the cold bend / cold impact requirement in
CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 & Annex
E at -40°C/-35°C.
IEC 60092-353
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-1, -2, -21
IEC 60754-1,2
IEC 61034-1,2
CSA 22.2 0.3-01 (-40°C/35°C) / IEC 60092-350
Annex E (-40°C/-35°C)
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
- Cold Bend /
Cold Impact
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
B
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned annealed copper wire braid
Rubberized Polyamide tape
U
Flame retardant, halogen-free, mud and cold bend / cold impact resistant
thermoset compound, SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 01 BFOU 0.6/1kV P5/P12 3 x 50/25mm2 FLEX FLAME IEC 60092-353 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21 IEC
60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C)
DRAKA 01 = Draka Norsk Kabel
Marking text
Manufacturing
unit
Outer sheath
colour
Black
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
Subject to change without prior notice
Page 137 of 212
Core identification power cables
Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445: Edition 5.0 2010-08 -
Range and dimensions
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
Diameter
inner
covering,
mm
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
1
16
4
5.15
1.0
1.1
10 ± 0.8
0.2
5.3
1.2
1
25
6
6.45
1.2
1.1
0.3
8.5
1.3
1
50
10
9.0
1.4
1.1
0.3
12.7
1.4
1
70
10
10.85
1.4
1.1
1
1
1
1
1
1
95
120
150
185
240
300
10
10
10
10
16
16
12.60
14.20
15.90
17.70
20.15
22.60
1.6
1.6
1.8
2.0
2.2
2.4
2
1.5
4
1.6
3
1.5
6
4
1.5
5
7
Diameter
outer
sheath,
mm
13.5 ±
0.8
15.5 ±
0.8
19 ± 0.8
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
380
198
540
314
880
559
0.3
12.7
1.4
21 ± 1
1130
757
1.1
1.2
1.2
1.2
1.2
1.2
11.5 ±
0.8
15 ± 0.8
16.5 ±
0.8
19 ± 0.8
20.5 ± 1
23 ± 1
25 ± 1
28 ± 1
31 ± 1.5
0.3
0.3
0.3
0.3
0.3
0.3
15.3
15.3
17.8
17.8
20.4
22.9
1.5
1.6
1.7
1.7
1.8
1.9
23.5 ± 1
25.5 ± 1
28 ± 1
30 ± 1.5
33 ± 1.5
36 ± 1.5
1440
1740
2130
2510
3160
3880
996
1231
1535
1838
2365
2984
1.0
1.1
10 ± 0.8
0.2
5.3
1.2
290
80
1.6
1.0
1.1
0.3
8.5
1.3
360
125
6
1.6
1.0
1.1
0.3
10.2
1.3
1.5
1.5
6
6
1.6
1.6
1.0
1.0
1.1
1.1
0.3
0.3
10.2
11.9
12
1.5
10
1.6
1.0
1.2
0.3
19
27
37
1.5
1.5
1.5
10
16
16
1.6
1.6
1.6
1.0
1.0
1.0
1.2
1.2
1.4
2
2.5
6
2.0
1.0
1.1
3
2.5
6
2.0
1.0
1.1
4
2.5
6
2.0
1.0
1.1
7
2.5
6
2.0
1.0
1.1
12
19
2.5
2.5
10
16
2.0
2.0
1.0
1.0
27
2.5
16
2.0
37
2.5
25
3G
2.5
2
3
10.5 ±
0.8
11.5 ±
0.8
13 ± 0.8
13 ± 0.8
17.5 ±
0.8
20.5 ± 1
24.5 ± 1
27.5 ± 1
420
156
1.4
1.4
13.5 ±
0.8
14.5 ±
0.8
15.5 ±
0.8
17 ± 0.8
17 ± 0.8
490
540
170
214
15.3
1.6
22 ± 1
810
318
0.3
0.3
0.3
17.8
20.4
22.9
1.7
1.9
2
25 ± 1
29.5 ± 1
33 ± 1.5
1100
1450
1870
440
577
741
0.3
8.5
1.3
370
129
0.3
10.2
1.3
430
169
0.3
10.2
1.3
15 ± 0.8
15.5 ±
0.8
16.5 ±
0.8
18.5 ±
0.8
23.5 ± 1
27.5 ± 1
32.5 ±
1.5
36.5 ±
1.5
15.5 ±
0.8
480
192
640
277
990
1380
450
636
1870
844
2500
1204
430
169
460
510
173
210
610
263
510
210
540
209
0.3
11.9
1.4
1.2
1.2
11 ± 0.8
11.5 ±
0.8
12.5 ±
0.8
14.5 ±
0.8
19 ± 0.8
22.5 ± 1
0.3
0.3
17.8
20.4
1.6
1.8
1.0
1.4
27 ± 1
0.3
22.9
2
2.0
1.0
1.4
0.4
36.2
2.2
-
2.0
1.0
1.1
0.3
10.2
1.3
4
4
6
6
2.55
2.55
1.0
1.0
1.1
1.1
12 ± 0.8
13 ± 0.8
0.3
0.3
10.2
10.2
1.3
1.3
4
4
6
2.55
1.0
1.1
14 ± 0.8
0.3
11.9
1.4
3G
4
-
2.55
1.0
1.1
13 ± 0.8
0.3
10.2
1.3
2
6
6
3.15
1.0
1.1
13.5 ±
0.8
0.3
10.2
1.4
Subject to change without prior notice
30.5 ±
1.5
11.5 ±
0.8
16 ± 0.8
17 ± 0.8
18.5 ±
0.8
16.5 ±
0.8
17.5 ±
0.8
Page 138 of 212
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
Diameter
inner
covering,
mm
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
3
14 ± 0.8
0.3
11.9
1.4
0.3
11.9
1.4
0.3
13.6
1.5
0.3
0.3
0.3
0.3
11.9
11.9
13.6
15.3
0.5
6
6
3.15
1.0
1.1
4
6
6
3.15
1.0
1.1
5G
6
-
3.15
1.0
1.1
2
3
4
5G
10
10
10
10
10
10
10
-
4.05
4.05
4.05
4.05
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.2
2
16
16
5.15
1.0
1.1
3
16
16
5.15
1.0
1.1
4
16
16
5.15
1.0
2
3
4
25
25
25
16
16
16
6.45
6.45
6.45
2
3
4
35
35
35
16
16
16
5G
35
3
50
15.5 ±
0.8
17.5 ±
0.8
15 ± 0.8
16 ± 0.8
18 ± 0.8
20 ± 1
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
630
281
730
335
21.5 ± 1
890
406
1.4
1.5
1.5
1.6
19 ± 0.8
20.5 ± 1
22 ± 1
24.5 ± 1
690
810
980
1190
299
390
496
603
21.2
1.5
22.5 ± 1
990
500
18.5 ±
0.8
19.5 ±
0.8
0.4
22.6
1.5
23 ± 1
1170
660
1.2
17.5 ±
0.8
18.5 ±
0.8
21 ± 1
0.4
22.6
1.6
25.5 ± 1
1410
806
1.2
1.2
1.2
1.2
1.2
1.2
21 ± 1
22.5 ± 1
25 ± 1
0.4
0.3
0.3
22.6
20.4
20.4
1.6
1.7
1.8
26 ± 1
27.5 ± 1
30 ± 1.5
1370
1610
1960
685
894
1125
7.65
7.65
7.65
1.2
1.2
1.2
1.2
1.2
1.2
0.3
0.3
0.3
20.4
20.4
20.4
1.7
1.8
1.9
828
1142
1456
7.65
1.2
1.4
0.3
22.9
2
28.5 ± 1
30 ± 1.5
33 ± 1.5
36.5 ±
1.5
1650
2010
2470
-
23.5 ± 1
25.5 ± 1
28 ± 1
31.5 ±
1.5
2990
1795
25
9.0
1.4
1.2
29 ± 1
0.4
31.7
1.9
2720
1617
0.4
31.7
2
3360
2052
0.3
25.4
2
38 ± 1.5
3300
1991
0.4
36.2
2.2
42 ± 2
4090
2531
0.6
50.9
2
38 ± 1.5
3160
1783
4
50
25
9.0
1.4
1.4
4G
50
-
9.0
1.4
1.4
5G
50
-
9.0
1.4
1.4
2
70
35
10.85
1.4
1.6
3
70
35
10.85
1.4
1.4
4
5G
70
70
35
-
10.85
10.85
1.4
1.4
3
4
95
95
50
50
12.60
12.60
3
120
60
4
120
60
32.5 ±
1.5
32.5 ±
1.5
36 ± 1.5
34.5 ±
1.5
38.5 ±
1.5
0.5
49.5
2
39 ± 1.5
3750
2386
1.4
1.4
31.5 ±
1.5
33.5 ±
1.5
37 ± 1.5
41 ± 2
0.4
0.4
45.2
40.7
2.2
2.3
43 ± 2
47 ± 2
4580
5420
2977
3566
1.6
1.6
1.4
1.6
38 ± 1.5
42.5 ± 2
0.6
0.5
61.1
63.6
2.2
2.4
44.5 ± 2
49.5 ± 2
4900
6100
3168
4022
14.20
1.6
1.4
41.5 ± 2
0.6
71.3
2.4
6000
3976
14.20
1.6
1.6
46.5 ± 2
0.6
71.3
2.5
48.5 ± 2
53.5 ±
2.5
7430
5060
Ordering information
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
810200
810201
810203
810204
810205
810206
810207
810208
810209
810210
BFOU 0.6/1kV 1X16/4 P5/P12 Cold
BFOU 0.6/1kV 1X25/6 P5/P12 Cold
BFOU 0.6/1kV 1X50/10 P5/P12 Cold
BFOU 0.6/1kV 1X70/10 P5/P12 Cold
BFOU 0.6/1kV 1X95/10 P5/P12 Cold
BFOU 0.6/1kV 1X120/10 P5/P12 Cold
BFOU 0.6/1kV 1X150/10 P5/P12 Cold
BFOU 0.6/1kV 1X185/10 P5/P12 Cold
BFOU 0.6/1kV 1X240/16 P5/P12 Cold
BFOU 0.6/1kV 1X300/16 P5/P12 Cold
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528102000
7021528102017
7021528102031
7021528102048
7021528102055
7021528102062
7021528102079
7021528102086
7021528102093
7021528102109
-
810215
810218
810219
810220
BFOU 0.6/1kV 2X1.5/4 P5/P12 Cold
BFOU 0.6/1kV 3X1.5/6 P5/P12 Cold
BFOU 0.6/1kV 4X1.5/6 P5/P12 Cold
BFOU 0.6/1kV 5X1.5/6 P5/P12 Cold
BLACK
BLACK
BLACK
BLACK
-
7021528102154
7021528102185
7021528102192
7021528102208
-
Subject to change without prior notice
Page 139 of 212
New Part
number
Old Part
number
810221
810222
810223
810224
810225
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
BFOU 0.6/1kV 7X1.5/6 P5/P12 Cold
BFOU 0.6/1kV 12X1.5/10 P5/P12 Cold
BFOU 0.6/1kV 19X1.5/10 P5/P12 Cold
BFOU 0.6/1kV 27X1.5/16 P5/P12 Cold
BFOU 0.6/1kV 37X1.5/16 P5/P12 Cold
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528102215
7021528102222
7021528102239
7021528102246
7021528102253
-
BFOU 0.6/1kV 2X2.5/6 P5/P12 Cold
BFOU 0.6/1kV 3X2.5/6 P5/P12 Cold
BFOU 0.6/1kV 4X2.5/6 P5/P12 Cold
BFOU 0.6/1kV 7X2.5/6 P5/P12 Cold
BFOU 0.6/1kV 12X2.5/10 P5/P12 Cold
BFOU 0.6/1kV 19X2.5/16 P5/P12 Cold
BFOU 0.6/1kV 27X2.5/16 P5/P12 Cold
BFOU 0.6/1kV 37X2.5/25 P5/P12 Cold
BFOU 0.6/1kV 3G2.5 P5/P12 Cold
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
Yes
-
7021528102291
7021528102321
7021528102352
7021528102376
7021528102383
7021528102390
7021528102406
7021528102413
-
-
810245
810246
810247
BFOU 0.6/1kV 2X4/6 P5/P12 Cold
BFOU 0.6/1kV 3X4/6 P5/P12 Cold
BFOU 0.6/1kV 4X4/6 P5/P12 Cold
BFOU 0.6/1kV 3G 4 P5/P12 Cold
BLACK
BLACK
BLACK
BLACK
-
7021528102451
7021528102468
7021528102475
7021528102505
-
810251
810252
810253
Tba
BFOU 0.6/1kV 2X6/6 P5/P12 Cold
BFOU 0.6/1kV 3X6/6 P5/P12 Cold
BFOU 0.6/1kV 4X6/6 P5/P12 Cold
BFOU 0.6/1kV 5G 6 P5/P12 Cold
BLACK
BLACK
BLACK
BLACK
-
7021528102512
7021528102529
7021528102536
-
-
810257
810258
810259
Tba
BFOU 0.6/1kV 2X10/10 P5/P12 Cold
BFOU 0.6/1kV 3X10/10 P5/P12 Cold
BFOU 0.6/1kV 4X10/10 P5/P12 Cold
BFOU 0.6/1kV 5G 10 P5/P12 Cold
BLACK
BLACK
BLACK
BLACK
-
7021528102574
7021528102581
7021528102598
-
-
810263
810264
810265
BFOU 0.6/1kV 2X16/16 P5/P12 Cold
BFOU 0.6/1kV 3X16/16 P5/P12 Cold
BFOU 0.6/1kV 4X16/16 P5/P12 Cold
BLACK
BLACK
BLACK
-
7021528102635
7021528102642
7021528102659
-
810269
810270
810271
BFOU 0.6/1kV 2X25/16 P5/P12 Cold
BFOU 0.6/1kV 3X25/16 P5/P12 Cold
BFOU 0.6/1kV 4X25/16 P5/P12 Cold
BLACK
BLACK
BLACK
-
7021528102697
7021528102703
7021528102710
-
810275
810276
810277
Tba
BFOU 0.6/1kV 2X35/16 P5/P12 Cold
BFOU 0.6/1kV 3X35/16 P5/P12 Cold
BFOU 0.6/1kV 4X35/16 P5/P12 Cold
BFOU 0.6/1kV 5G 35 P5/P12 Cold
BLACK
BLACK
BLACK
BLACK
-
7021528102758
7021528102765
7021528102772
-
-
810282
810283
Tba
Tba
BFOU 0.6/1kV 3X50/25 P5/P12 Cold
BFOU 0.6/1kV 4X50/25 P5/P12 Cold
BFOU 0.6/1kV 4G 50 P5/P12 Cold
BFOU 0.6/1kV 5G 50 P5/P12 Cold
BLACK
BLACK
BLACK
BLACK
-
7021528102826
7021528102833
-
-
810287
810288
810289
Tba
BFOU 0.6/1kV 2X70/35 P5/P12 Cold
BFOU 0.6/1kV 3X70/35 P5/P12 Cold
BFOU 0.6/1kV 4X70/35 P5/P12 Cold
BFOU 0.6/1kV 5G 70 P5/P12 Cold
BLACK
BLACK
BLACK
BLACK
-
7021528102871
7021528102888
7021528102895
-
-
810295
810296
BFOU 0.6/1kV 3X95/50 P5/P12 Cold
BFOU 0.6/1kV 4X95/50 P5/P12 Cold
BLACK
BLACK
-
7021528102956
7021528102963
-
810301
810304
BFOU 0.6/1kV 3X120/60 P5/P12 Cold
BFOU 0.6/1kV 4X120/60 P5/P12 Cold
BLACK
BLACK
-
7021528103014
7021528103045
-
810229
810232
810235
20115940
810238
810239
810240
810241
Tba
20110769
Subject to change without prior notice
Page 140 of 212
Electrical values power cables
Number of
elements
Cross
section
core,
mm²
Electrical
Cross
section
braid, mm²
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table
second,
B.4, Ampere
Ampere
1
1
1
1
1
1
1
1
1
1
16
25
50
70
95
120
150
185
240
300
4
6
10
10
10
10
10
10
16
16
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
1.16
0.734
0.391
0.27
0.195
0.154
0.126
0.1
0.0762
0.0607
1.48
0.936
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
0.119
0.115
0.106
0.101
0.098
0.096
0.094
0.092
0.09
0.088
0.143
0.138
0.127
0.121
0.117
0.115
0.113
0.111
0.109
0.106
96
127
196
242
293
339
389
444
522
601
2240
3500
7000
9800
13300
16800
21000
25900
33600
42000
2
3
4
5
7
12
19
27
37
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
4
6
6
6
6
10
10
16
16
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.138
0.138
0.138
0.138
0.138
0.138
0.138
0.138
0.138
20
16
16
13.5
12
10
8.5
7.5
7
210
210
210
210
210
210
210
210
210
2
3
4
7
12
19
27
37
3G
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
6
6
6
6
10
16
16
25
-
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
0.107
0.107
0.107
0.107
0.107
0.107
0.107
0.107
0.107
0.129
0.129
0.129
0.129
0.129
0.129
0.129
0.129
0.129
26
21
21
15.5
13
11
10
9
26
350
350
350
350
350
350
350
350
350
2
3
4
3G
4
4
4
4
6
6
6
-
STCC
STCC
STCC
STCC
4.7
4.7
4.7
4.7
5.99
5.99
5.99
5.99
0.100
0.100
0.1
0.100
0.120
0.120
0.120
0.120
34
28
28
34
560
560
560
560
2
3
4
5G
6
6
6
6
6
6
6
-
STCC
STCC
STCC
STCC
3.11
3.11
3.11
3.11
3.97
3.97
3.97
3.97
0.094
0.094
0.094
0.094
0.112
0.112
0.112
0.112
44
36
36
36
840
840
840
840
2
3
4
5G
10
10
10
10
10
10
10
-
STCC
STCC
STCC
STCC
1.84
1.84
1.84
1.84
2.35
2.35
2.35
2.35
0.088
0.088
0.088
0.088
0.105
0.105
0.105
0.105
61
50
50
50
1400
1400
1400
1400
2
3
4
16
16
16
16
16
16
STCC
STCC
STCC
1.16
1.16
1.16
1.48
1.48
1.48
0.082
0.082
0.082
0.099
0.099
0.099
80
67
67
2240
2240
2240
2
3
4
25
25
25
16
16
16
STCC
STCC
STCC
0.734
0.734
0.734
0.936
0.936
0.936
0.081
0.081
0.081
0.098
0.098
0.098
108
89
89
3500
3500
3500
2
3
4
5G
35
35
35
35
16
16
16
-
STCC
STCC
STCC
STCC
0.529
0.529
0.529
0.529
0.675
0.675
0.675
0.675
0.078
0.078
0.078
0.078
0.094
0.094
0.094
0.094
133
110
110
110
4900
4900
4900
4900
3
4
4G
5G
50
50
50
50
25
25
-
STCC
STCC
STCC
STCC
0.391
0.391
0.391
0.391
0.499
0.499
0.499
0.499
0.078
0.078
0.078
0.078
0.093
0.093
0.093
0.093
137
137
137
137
7000
7000
7000
7000
2
3
4
5G
70
70
70
70
35
35
35
-
STCC
STCC
STCC
STCC
0.27
0.27
0.27
0.27
0.344
0.344
0.344
0.344
0.075
0.077
0.077
0.077
0.092
0.092
0.092
0.092
206
169
169
169
9800
9800
9800
9800
Subject to change without prior notice
Page 141 of 212
Number of
elements
Cross
section
core,
mm²
Electrical
Cross
section
braid, mm²
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table
second,
B.4, Ampere
Ampere
3
4
95
95
50
50
STCC
STCC
0.195
0.195
0.249
0.249
0.075
0.075
0.090
0.090
205
205
13300
13300
3
4
120
120
60
60
STCC
STCC
0.154
0.154
0.196
0.196
0.073
0.073
0.088
0.088
237
237
16800
16800
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-40°C
Page 142 of 212
ARCTIC GRADE Fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, double braided
Fire resistant, flame retardant halogenfree power cable. Oil & Mud resistant.
Cold bend / Cold impact resistant.
Double braided.
BFOU 0,6/1(1,2)kV
MGT/EPR/EPR/TCWB/EVA
NEK TS 606 CodeP5/P12 Arctic Grade
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
Fixed installation for power, control and lighting in both EX
(Zone 0, 1 & 2)- and safe areas, emergency and critical
systems where requirement for fire resistance exists. For
installation in areas exposed to MUD and drilling/cleaning
fluids. Meets the OIL & MUD resistance requirement in
NEK 606. Meets the cold bend / cold impact requirement in
CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 & Annex
E at -40°C/-35°C.
IEC 60092-353
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-1, -2, -21
IEC 60754-1,2
IEC 61034-1,2
CSA 22.2 0.3-01 (-40°C/35°C) / IEC 60092-350
Annex E (-40°C/-35°C)
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
- Cold Bend / Cold
Impact
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
B
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Two layers of tinned copper wire braid (double braid)
Rubberized Polyamide tape
U
Flame retardant, halogen-free, mud and cold bend / cold impact resistant
thermoset compound, SHF2 (IEC 60092-360)
E.g. "meter" "year" DRAKA 01 BFOU 0.6/1kV P5/P12 3 x 50/25mm2 FLEX FLAME IEC 60092-353 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21 IEC
60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C)
DRAKA 01 = Draka Norsk Kabel
Marking text
Manufacturing
unit
Outer sheath
colour
Black
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
Subject to change without prior notice
Page 143 of 212
Core identification power cables
Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445: Edition 5.0 2010-08 -
Range and dimensions
Electrical
Cross
Thickness
Number
Cross
Conductor Insulation
section
Inner
of
section
Diameter, Thickness,
core,
covering,
elements
braid,
mm
mm
mm²
mm
mm²
Diameter
inner
covering,
mm
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
3
150
75
15.90
1.8
1.4
46.5 ± 2
0.4
86
2.6
4
150
75
15.90
1.8
1.6
52 ± 2.5
0.5
99
3
185
95
17.70
2.0
1.6
185
95
17.7
2.0
1.8
51 ± 2.5
57.5 ±
2.5
0.5
4
0.4
3
240
120
19.1
2.2
2.0
56.0 ±2.0 0.7
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
7480
4992
2.8
54.5 ±
2.5
61 ± 3
9440
6451
127.2
2.8
60.5 ± 3
9310
6295
54.3
2.9
68±3
11590
7750
138.5
3.0
65.0 ±
3.0
11830
8042
Ordering information
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
810302
810309
BFOU 0.6/1kV 3X150/75 P5/P12 Cold
BFOU 0.6/1kV 4X150/75 P5/P12 Cold
BLACK
BLACK
-
7021528103021
7021528103090
-
810392
810391
BFOU 0.6/1kV 3X185/95 P5/P12 Cold
BFOU 0.6/1kV 4X185/95 P5/P12 Cold
BLACK
BLACK
-
7021528103922
7021528103915
-
810314
BFOU 0.6/1kV 3X240/120 P5/P12Cold
BLACK
-
7021528103144
-
Electrical values power cables
Number of
elements
Cross
section
core,
mm²
Electrical
Cross
section
braid, mm²
Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
type 2
resistance at
resistance at
50Hz,
60Hz,
IEC 60092rating 1
20°C, Ohm/km 90°C, Ohm/km
Ohm/km
Ohm/km
352 Table
second,
B.4, Ampere
Ampere
3
4
150
150
75
75
STCC
STCC
0.126
0.126
0.161
0.161
0.073
0.073
0.088
0.088
272
272
21000
21000
3
4
185
185
95
95
STCC
STCC
0.1
0.1
0.128
0.128
0.073
0.073
0.088
0.088
311
311
25900
25900
3
240
120
STCC
0.0762
0.0972
0.074
0.089
365
33600
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius Fixed
Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-40°C
Page 144 of 212
eXtended Fire Resistant, instrumentation cable BFOU-XFR(i) 150/250(300)V
eXtended Fire Resistant, flame retardant
halogen-free instrumentation cable. Mud
resistant
BFOU-XFR(i)
150/250(300)V
MGT/EPR/EPR/TCWB/EVA
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation,
communication, control and alarm systems in both
EX- and safe areas, emergency and critical
systems where requirement for fire resistance
exists. Meets the mud resistant requirements in
NEK TS 606:2009.
Cables have extended fire resistant (XFR)
properties to IEC 60331-1&2 including water spray
according to EN 50200 Annex E (90 minutes).
IEC 60092-376 (2003-05)
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-1,-2
EN 50200:2006 Annex E
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Lay up /
Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped
with a PETP tape.
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
Eg. "meter" "year" DRAKA 01 BFOU-XFR(I) 250V 4PAIR 1.5mm2 FLEX - FLAME
IEC 60092-376 EN 50200:2006 Annex E IEC 60331-1*) or IEC 60331-2*) IEC
60332-3-22
DRAKA 01 = Draka Norsk Kabel
Grey or Blue
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
Subject to change without prior notice
Page 145 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
1
2
0.75
1.1
1
1.1
9.5 ± 0.5 0.2
5.3
1.1
1
2
0.75
1.1
1
1.1
9.5 ± 0.5 0.2
5.3
1.1
2
2
0.75
1.1
1
1.1
0.3
11.9
1.3
2
2
0.75
1.1
1
1.1
4
4
8
8
2
2
2
2
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1
1
1
1
12
2
0.75
1.1
12
2
0.75
16
2
16
24
24
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
265
69
265
69
18 ± 0.8
470
150
12.5 ±
0.8
12.5 ±
0.8
0.3
11.9
1.3
18 ± 0.8
470
150
1.1
1.1
1.1
1.1
14.5 ±
0.8
14.5 ±
0.8
17 ± 0.8
17 ± 0.8
23.5 ± 1
23.5 ± 1
0.3
0.3
0.3
0.3
13.6
13.6
17.8
17.8
1.4
1.4
1.6
1.6
650
650
1060
1060
200
200
308
308
1
1.4
28 ± 1
0.3
20.4
1.7
1450
400
1.1
1
1.4
28 ± 1
0.3
20.4
1.7
1450
400
0.75
1.1
1
1.9
0.3
22.9
1.8
1940
491
2
0.75
1.1
1
1.9
2
2
0.75
0.75
1.1
1.1
1
1
2.3
2.3
1
3
0.75
1.1
1
1.1
1
3
0.75
1.1
1
1.1
2
3
0.75
1.1
1
2
3
0.75
1.1
21 ± 1
21 ± 1
27.5 ± 1
27.5 ± 1
32.5 ±
1.5
32.5 ±
1.5
37.5 ±
1.5
37.5 ±
1.5
46.5 ± 2
46.5 ± 2
13.5 ±
0.8
13.5 ±
0.8
19.5 ±
0.8
19.5 ±
0.8
4
3
0.75
4
3
8
8
12
12
16
16
24
24
32.5 ±
1.5
32.5 ±
1.5
40.5 ± 2
40.5 ± 2
10.5 ±
0.8
10.5 ±
0.8
0.3
22.9
1.8
0.4
0.4
40.7
40.7
2.1
2.1
0.2
5.3
1.1
0.2
5.3
1.1
1.1
16 ± 0.8
0.3
11.9
1.4
1
1.1
16 ± 0.8
0.3
11.9
1.4
1.1
1
1.1
0.3
15.3
1.4
0.75
1.1
1
1.1
0.3
15.3
3
3
3
3
3
3
3
3
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1
1
1
1
1
1
1
1
1.1
1.1
1.4
1.4
2.1
2.1
2.5
2.5
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
1
2
1.5
1.6
1
1.1
1
2
1.5
1.6
1
1.1
2
2
4
4
2
2
2
2
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1
1
1
1
1.1
1.1
1.1
1.1
18.5 ±
0.8
18.5 ±
0.8
25 ± 1
25 ± 1
31 ± 1.5
31 ± 1.5
36 ± 1.5
36 ± 1.5
45 ± 2
45 ± 2
10.5 ±
0.8
10.5 ±
0.8
16 ± 0.8
16 ± 0.8
19 ± 0.8
19 ± 0.8
8
2
1.5
1.6
1
1.1
8
2
1.5
1.6
1
1.1
12
2
1.5
1.6
1
1.4
12
2
1.5
1.6
1
1.4
16
16
2
2
1.5
1.5
1.6
1.6
1
1
24
2
1.5
1.6
24
2
1.5
1.6
Subject to change without prior notice
1940
491
2950
2950
799
799
290
75
290
75
540
163
540
163
22.5 ± 1
780
243
1.4
22.5 ± 1
780
243
20.4
20.4
22.9
22.9
25.4
25.4
45.2
45.2
1.7
1.7
1.8
1.8
1.9
1.9
2.2
2.2
1320
1320
1830
1830
2480
2480
3730
3730
386
386
503
503
621
621
1000
1000
0.2
5.3
1.1
310
86
0.2
5.3
1.1
310
86
0.3
0.3
0.3
0.3
13.6
13.6
15.3
15.3
1.4
1.4
1.5
1.5
580
580
820
820
201
201
286
286
26 ± 1
0.3
20.4
1.7
1360
472
26 ± 1
0.3
20.4
1.7
1360
472
0.3
22.9
1.9
29.5 ± 1
29.5 ± 1
36 ± 1.5
36 ± 1.5
41.5 ± 2
41.5 ± 2
51 ± 2.5
51 ± 2.5
13.5 ±
0.8
13.5 ±
0.8
20 ± 1
20 ± 1
23 ± 1
23 ± 1
30.5 ±
1.5
30.5 ±
1.5
36.5 ±
1.5
36.5 ±
1.5
42.5 ± 2
42.5 ± 2
51.5 ±
2.5
51.5 ±
1910
633
0.3
22.9
1.9
2.1
2.1
31.5 ±
1.5
31.5 ±
1.5
37 ± 1.5
37 ± 1.5
0.4
0.4
36.2
36.2
2
2
1
2.3
45.5 ± 2
0.4
45.2
2.3
1
2.3
45.5 ± 2
0.4
45.2
2.3
1910
633
2700
2700
899
899
3810
1259
3810
1259
Page 146 of 212
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
2.5
14.5 ±
0.8
14.5 ±
0.8
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
360
108
360
108
680
230
1
3
1.5
1.6
1
1.1
1
3
1.5
1.6
1
1.1
2
3
1.5
1.6
1
1.1
2
3
1.5
1.6
1
1.1
4
4
3
3
1.5
1.5
1.6
1.6
1
1
1.1
1.1
11.5 ±
0.8
11.5 ±
0.8
17.5 ±
0.8
17.5 ±
0.8
21 ± 1
21 ± 1
8
3
1.5
1.6
1
1.1
28 ± 1
0.3
20.4
1.8
8
3
1.5
1.6
1
1.1
28 ± 1
0.3
20.4
1.8
0.3
25.4
2
40.5 ± 2
2470
828
0.3
25.4
2
40.5 ± 2
2470
828
0.4
0.4
0.5
0.5
40.7
40.7
63.6
63.6
2.2
2.2
2.6
2.6
3480
3480
5170
5170
1171
1171
1781
1781
0.2
6
1.2
360
114
0.2
6
1.2
47 ± 2
47 ± 2
58 ± 2.5
58 ± 2.5
14.5 ±
0.8
14.5 ±
0.8
360
114
0.3
13.6
1.5
21.5 ± 1
660
242
0.3
13.6
1.5
21.5 ± 1
660
242
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
15.3
15.3
20.4
20.4
25.4
25.4
40.7
40.7
1.6
1.6
1.8
1.8
2
2
2.2
2.2
25 ± 1
25 ± 1
33 ± 1.5
33 ± 1.5
41.5 ± 2
41.5 ± 2
46.5 ± 2
46.5 ± 2
15.5 ±
0.8
15.5 ±
0.8
23 ± 1
23 ± 1
27 ± 1
27 ± 1
35.5 ±
1.5
35.5 ±
1.5
46.5 ± 2
46.5 ± 2
970
970
1620
1620
2570
2570
3330
3330
367
367
634
634
901
901
1268
1268
410
137
410
137
790
790
1200
1200
305
305
484
484
2120
844
2120
844
3490
3490
1328
1328
0.2
6
1.2
0.2
6
1.2
0.3
13.6
1.5
22 ± 1
0.3
13.6
1.5
22 ± 1
680
230
0.3
0.3
17.8
17.8
1.6
1.6
25 ± 1
25 ± 1
32.5 ±
1.5
32.5 ±
1.5
1030
1030
368
368
1680
586
1680
586
12
3
1.5
1.6
1
1.6
12
3
1.5
1.6
1
1.6
16
16
24
24
3
3
3
3
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1
1
1
1
2.3
2.3
2.7
2.7
1
2
2.5
2
1
1.1
1
2
2.5
2
1
1.1
2
2
2.5
2
1
1.1
2
2
2.5
2
1
1.1
4
4
8
8
12
12
16
16
2
2
2
2
2
2
2
2
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1.1
1.1
1.1
1.1
2.3
2.3
2.3
2.3
35.5 ±
1.5
35.5 ±
1.5
41 ± 2
41 ± 2
51 ± 2.5
51 ± 2.5
11.5 ±
0.8
11.5 ±
0.8
17.5 ±
0.8
17.5 ±
0.8
20.5 ± 1
20.5 ± 1
28.5 ± 1
28.5 ± 1
36 ± 1.5
36 ± 1.5
40.5 ± 2
40.5 ± 2
1
3
2.5
2
1
1.1
12 ± 0.8
0.2
6
1.2
1
3
2.5
2
1
1.1
12 ± 0.8
0.2
6
1.2
2
2
4
4
3
3
3
3
2.5
2.5
2.5
2.5
2
2
2
2
1
1
1
1
1.1
1.1
1.1
1.1
0.3
0.3
0.3
0.3
15.3
15.3
17.8
17.8
1.5
1.5
1.6
1.6
8
3
2.5
2
1
1.3
0.3
22.9
2
8
3
2.5
2
1
1.3
0.3
22.9
2
12
12
3
3
2.5
2.5
2
2
1
1
2.6
2.6
19 ± 0.8
19 ± 0.8
22.5 ± 1
22.5 ± 1
30.5 ±
1.5
30.5 ±
1.5
40.5 ± 2
40.5 ± 2
0.4
0.4
40.7
40.7
2.2
2.2
Electrical values instrumentation cables
Type
Capacitance, approx.
(nF/km)
Inductance, approx,
(mH/km)
Resistance at 20°C, max.
(Ohm/km)
L/R ratio,
(microH/Ohm)
Shielded pair 0,75 mm²
Shielded triple 0,75 mm²
65
65
0,94
0,94
26,3
26,3
17,9
17,9
Shielded pair 1,5 mm²
Shielded triple 1,5 mm²
80
80
0,84
0,84
12,9
12,9
32,6
32,6
Shielded pair 2,5 mm²
Shielded triple 2,5 mm²
100
100
0,77
0,77
8,02
8,02
48
48
Subject to change without prior notice
Page 147 of 212
Ordering information
New Part
number
Old Part
number
822300
822301
822306
822307
822318
822319
822330
822331
822336
822337
822342
822343
822348
822349
822360
822361
822366
822367
822378
822379
822390
822391
822396
822397
822402
822403
822408
822409
822700
822701
822706
822707
822718
822719
822730
822731
822736
822737
822742
822743
822748
822749
822760
822761
822766
822767
822778
822779
822790
822791
822796
822797
822802
822803
822808
822809
828900
828901
828906
828907
828918
Description
BFOU-XFR(I) 1PAIR 0.75mm²
BFOU-XFR(I) 1PAIR 0.75mm²
BFOU-XFR(I) 2PAIR 0.75mm²
BFOU-XFR(I) 2PAIR 0.75mm²
BFOU-XFR(I) 4PAIR 0.75mm²
BFOU-XFR(I) 4PAIR 0.75mm²
BFOU-XFR(I) 8PAIR 0.75mm²
BFOU-XFR(I) 8PAIR 0.75mm²
BFOU-XFR(I) 12PAIR 0.75mm²
BFOU-XFR(I) 12PAIR 0.75mm²
BFOU-XFR(I) 16PAIR 0.75mm²
BFOU-XFR(I) 16PAIR 0.75mm²
BFOU-XFR(I) 24PAIR 0.75mm²
BFOU-XFR(I) 24PAIR 0.75mm²
BFOU-XFR(I) 1TRIP 0.75mm²
BFOU-XFR(I) 1TRIP 0.75mm²
BFOU-XFR(I) 2TRIP 0.75mm²
BFOU-XFR(I) 2TRIP 0.75mm²
BFOU-XFR(I) 4TRIP 0.75mm²
BFOU-XFR(I) 4TRIP 0.75mm²
BFOU-XFR(I) 8TRIP 0.75mm²
BFOU-XFR(I) 8TRIP 0.75mm²
BFOU-XFR(I) 12TRIP 0.75mm²
BFOU-XFR(I) 12TRIP 0.75mm²
BFOU-XFR(I) 16TRIP 0.75mm²
BFOU-XFR(I) 16TRIP 0.75mm²
BFOU-XFR(I) 24TRIP 0.75mm²
BFOU-XFR(I) 24TRIP 0.75mm²
BFOU-XFR(I) 1PAIR 1.5mm²
BFOU-XFR(I) 1PAIR 1.5mm²
BFOU-XFR(I) 2PAIR 1.5mm²
BFOU-XFR(I) 2PAIR 1.5mm²
BFOU-XFR(I) 4PAIR 1.5mm²
BFOU-XFR(I) 4PAIR 1.5mm²
BFOU-XFR(I) 8PAIR 1.5mm²
BFOU-XFR(I) 8PAIR 1.5mm²
BFOU-XFR(I) 12PAIR 1.5mm²
BFOU-XFR(I) 12PAIR 1.5mm²
BFOU-XFR(I) 16PAIR 1.5mm²
BFOU-XFR(I) 16PAIR 1.5mm²
BFOU-XFR(I) 24PAIR 1.5mm²
BFOU-XFR(I) 24PAIR 1.5mm²
BFOU-XFR(I) 1TRIP 1.5mm²
BFOU-XFR(I) 1TRIP 1.5mm²
BFOU-XFR(I) 2TRIP 1.5mm²
BFOU-XFR(I) 2TRIP 1.5mm²
BFOU-XFR(I) 4TRIP 1.5mm²
BFOU-XFR(I) 4TRIP 1.5mm²
BFOU-XFR(I) 8TRIP 1.5mm²
BFOU-XFR(I) 8TRIP 1.5mm²
BFOU-XFR(I) 12TRIP 1.5mm²
BFOU-XFR(I) 12TRIP 1.5mm²
BFOU-XFR(I) 16TRIP 1.5mm²
BFOU-XFR(I) 16TRIP 1.5mm²
BFOU-XFR(I) 24TRIP 1.5mm²
BFOU-XFR(I) 24TRIP 1.5mm²
BFOU-XFR(I) 1PAIR 2.5mm²
BFOU-XFR(I) 1PAIR 2.5mm²
BFOU-XFR(I) 2PAIR 2.5mm²
BFOU-XFR(I) 2PAIR 2.5mm²
BFOU-XFR(I) 4PAIR 2.5mm²
Subject to change without prior notice
Sheath Colour
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
Stock item
-
EAN No. DNK
7021528223002
7021528223019
7021528223064
7021528223071
7021528223187
7021528223194
7021528223309
7021528223316
7021528223361
7021528223378
7021528223422
7021528223439
7021528223484
7021528223491
7021528223606
7021528223613
7021528223668
7021528223675
7021528223781
7021528223798
7021528223903
7021528223910
7021528223965
7021528223972
7021528224023
7021528224030
7021528224085
7021528224092
7021528227000
7021528227017
7021528227062
7021528227079
7021528227185
7021528227192
7021528227307
7021528227314
7021528227369
7021528227376
7021528227420
7021528227437
7021528227482
7021528227499
7021528227604
7021528227611
7021528227666
7021528227673
7021528227789
7021528227796
7021528227901
7021528227918
7021528227963
7021528227970
7021528228021
7021528228038
7021528228083
7021528228090
7021528289008
7021528289015
7021528289060
7021528289077
7021528289183
Page 148 of 212
EL No.
-
New Part
number
Old Part
number
828919
828930
828931
828936
828937
828942
828943
828960
828961
828966
828967
828978
828979
828990
828991
828996
828997
Description
BFOU-XFR(I) 4PAIR 2.5mm²
BFOU-XFR(I) 8PAIR 2.5mm²
BFOU-XFR(I) 8PAIR 2.5mm²
BFOU-XFR(I) 12PAIR 2.5mm²
BFOU-XFR(I) 12PAIR 2.5mm²
BFOU-XFR(I) 16PAIR 2.5mm²
BFOU-XFR(I) 16PAIR 2.5mm²
BFOU-XFR(I) 1TRIP 2.5mm²
BFOU-XFR(I) 1TRIP 2.5mm²
BFOU-XFR(I) 2TRIP 2.5mm²
BFOU-XFR(I) 2TRIP 2.5mm²
BFOU-XFR(I) 4TRIP 2.5mm²
BFOU-XFR(I) 4TRIP 2.5mm²
BFOU-XFR(I) 8TRIP 2.5mm²
BFOU-XFR(I) 8TRIP 2.5mm²
BFOU-XFR(I) 12TRIP 2.5mm²
BFOU-XFR(I) 12TRIP 2.5mm²
Sheath Colour
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
Stock item
-
EAN No. DNK
7021528289190
7021528289305
7021528289312
7021528289367
7021528289374
7021528289428
7021528289435
7021528289602
7021528289619
7021528289664
7021528289671
7021528289787
7021528289794
7021528289909
7021528289916
7021528289961
7021528289978
EL No.
-
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius
Fixed Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 149 of 212
eXtended Fire Resistant, instrumentation cable BFOU-XFR(c) 150/250(300)V
eXtended Fire Resistant, flame retardant
halogen-free instrumentation cable. Mud
resistant
BFOU-XFR(c)
150/250(300)V
MGT/EPR/EPR/TCWB/EVA
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation,
communication, control and alarm systems in both
EX- and safe areas, emergency and critical systems
where requirement for fire resistance exists. Meets
the mud resistant requirements in NEK TS 606:2009.
Cables have extended fire resistant (XFR) properties
to IEC 60331-1&2 including water spray according to
EN 50200 Annex E (90 minutes).
IEC 60092-376 (2003-05)
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-1, -2
EN 50200:2006 Annex E
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
Eg. "meter" "year" DRAKA 01 BFOU-XFR(C) 250V 4PAIR 1.5mm2 FLEX - FLAME
IEC 60092-376 EN 50200:2006 Annex E IEC 60331-1*) or IEC 60331-2*) IEC
60332-3-22
DRAKA 01 = Draka Norsk Kabel
Grey or Blue
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
Subject to change without prior notice
Page 150 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
2
2
0.75
1.1
1
1.1
14 ± 0.8
0.3
10.2
1.3
2
2
0.75
1.1
1
1.1
14 ± 0.8
0.3
10.2
1.3
4
2
0.75
1.1
1
1.1
0.3
11.9
1.3
4
2
0.75
1.1
1
1.1
8
8
2
2
0.75
0.75
1.1
1.1
1
1
12
2
0.75
1.1
12
2
0.75
16
2
16
2
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
440
130
440
130
20 ± 1
580
172
17.5 ±
0.8
17.5 ±
0.8
0.3
11.9
1.3
20 ± 1
580
172
1.1
1.1
16.5 ±
0.8
16.5 ±
0.8
22 ± 1
22 ± 1
0.3
0.3
17.8
17.8
1.5
1.5
960
960
282
282
1
1.4
26.5 ± 1
0.3
20.4
1.6
1290
358
1.1
1
1.4
26.5 ± 1
0.3
20.4
1.6
1290
358
0.75
1.1
1
1.9
29.5 ± 1
0.3
22.9
1.7
1690
435
0.75
1.1
1
1.9
29.5 ± 1
0.3
22.9
1.7
26.5 ± 1
26.5 ± 1
30.5 ±
1.5
30.5 ±
1.5
34.5 ±
1.5
34.5 ±
1.5
1690
435
0.4
36.2
2
42.5 ± 2
2530
668
0.4
36.2
2
42.5 ± 2
2530
668
530
159
530
159
750
231
36.5 ±
1.5
36.5 ±
1.5
24
2
0.75
1.1
1
2.3
24
2
0.75
1.1
1
2.3
2
3
0.75
1.1
1
1.1
16 ± 0.8
0.3
11.9
1.3
2
3
0.75
1.1
1
1.1
16 ± 0.8
0.3
11.9
1.3
4
3
0.75
1.1
1
1.1
0.3
15.3
1.4
4
3
0.75
1.1
1
1.1
8
8
3
3
0.75
0.75
1.1
1.1
1
1
12
3
0.75
1.1
12
3
0.75
16
16
24
24
3
3
3
3
2
19.5 ±
0.8
19.5 ±
0.8
0.3
15.3
1.4
22.5 ± 1
750
231
1.1
1.1
18.5 ±
0.8
18.5 ±
0.8
25 ± 1
25 ± 1
0.3
0.3
17.8
17.8
1.6
1.6
1210
1210
334
334
1
1.4
30 ± 1.5
0.3
22.9
1.7
1670
461
1.1
1
1.4
30 ± 1.5
0.3
22.9
1.7
1670
461
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1
1
1
1
2.1
2.1
2.5
2.5
0.3
0.3
0.4
0.4
25.4
25.4
40.7
40.7
1.8
1.8
2.1
2.1
2240
2240
3340
3340
564
564
868
868
2
1.5
1.6
1
1.1
0.3
11.9
1.4
540
179
2
2
1.5
1.6
1
1.1
0.3
11.9
1.4
540
179
4
2
1.5
1.6
1
1.1
0.3
15.3
1.4
22 ± 1
750
268
4
2
1.5
1.6
1
1.1
0.3
15.3
1.4
22 ± 1
750
268
8
8
2
2
1.5
1.5
1.6
1.6
1
1
1.1
1.1
34 ± 1.5
34 ± 1.5
42.5 ± 2
42.5 ± 2
15.5 ±
0.8
15.5 ±
0.8
18.5 ±
0.8
18.5 ±
0.8
25 ± 1
25 ± 1
29 ± 1
29 ± 1
34.5 ±
1.5
34.5 ±
1.5
39 ± 1.5
39 ± 1.5
48 ± 2
48 ± 2
19.5 ±
0.8
19.5 ±
0.8
0.3
0.3
17.8
17.8
1.7
1.7
1210
1210
405
405
12
2
1.5
1.6
1
1.4
29.5 ± 1
0.3
22.9
1.8
1680
567
12
2
1.5
1.6
1
1.4
29.5 ± 1
0.3
22.9
1.8
1680
567
16
16
24
24
2
2
2
2
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1
1
1
1
1.9
1.9
2.3
2.3
0.3
0.3
0.4
0.4
25.4
25.4
40.7
40.7
1.9
1.9
2.2
2.2
2180
2180
3260
3260
704
704
1077
1077
2
3
1.5
1.6
1
1.1
0.3
13.6
1.4
21.5 ± 1
660
224
2
3
1.5
1.6
1
1.1
4
3
1.5
1.6
1
1.1
33 ± 1.5
33 ± 1.5
41 ± 2
41 ± 2
17.5 ±
0.8
17.5 ±
0.8
21 ± 1
29.5 ± 1
29.5 ± 1
34.5 ±
1.5
34.5 ±
1.5
38 ± 1.5
38 ± 1.5
47 ± 2
47 ± 2
Subject to change without prior notice
22.5 ± 1
0.3
13.6
1.4
21.5 ± 1
660
224
0.3
17.8
1.5
25 ± 1
960
350
Page 151 of 212
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
1.1
Mechanical
Diameter
Diameter crossinner
Braid
section of
covering,
Wire, mm the braid,
mm
mm²
21 ± 1
0.3
17.8
1.5
960
350
1
1.1
28 ± 1
0.3
20.4
1.8
1580
543
1.6
1
1.1
28 ± 1
0.3
20.4
1.8
1580
543
1.5
1.6
1
1.4
34 ± 1.5
0.3
25.4
1.9
2190
762
1.5
1.6
1
1.4
34 ± 1.5
0.3
25.4
1.9
25 ± 1
32.5 ±
1.5
32.5 ±
1.5
38.5 ±
1.5
38.5 ±
1.5
2190
762
0.4
40.7
2.1
44.5 ± 2
3150
1080
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
4
3
1.5
1.6
1
8
3
1.5
1.6
8
3
1.5
12
3
12
3
38.5 ±
1.5
38.5 ±
1.5
47.5 ± 2
47.5 ± 2
17 ± 0.8
17 ± 0.8
19.5 ±
0.8
19.5 ±
0.8
0.4
40.7
2.1
44.5 ± 2
3150
1080
0.4
0.4
0.3
0.3
45.2
45.2
13.6
13.6
2.4
2.4
1.4
1.4
54 ± 2.5
54 ± 2.5
20.5 ± 1
20.5 ± 1
4450
4450
620
620
1462
1462
234
234
0.3
15.3
1.5
24 ± 1
880
343
0.3
15.3
1.5
24 ± 1
880
343
1480
577
1480
577
2240
811
2240
811
16
3
1.5
1.6
1
2.3
16
3
1.5
1.6
1
2.3
24
24
2
2
3
3
2
2
1.5
1.5
2.5
2.5
1.6
1.6
2
2
1
1
1
1
2.7
2.7
1.1
1.1
4
2
2.5
2
1
1.1
4
2
2.5
2
1
1.1
8
2
2.5
2
1
1.1
27 ± 1
0.3
20.4
1.8
8
2
2.5
2
1
1.1
27 ± 1
0.3
20.4
1.8
12
2
2.5
2
1
2.1
0.3
25.4
1.9
12
2
2.5
2
1
2.1
0.3
25.4
1.9
16
2
2.5
2
1
2.3
0.4
36.2
2.1
42.5 ± 2
2900
1101
16
2
2.5
2
1
2.3
0.4
36.2
2.1
42.5 ± 2
2900
1101
24
2
2.5
2
1
2.7
45 ± 2
0.4
45.2
2.4
4150
1558
24
2
2.5
2
1
2.7
45 ± 2
0.4
45.2
2.4
4150
1558
2
2
4
4
8
8
12
12
16
16
3
3
3
3
3
3
3
3
3
3
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1.1
1.1
1.1
1.1
1.1
1.1
2.6
2.6
2.6
2.6
19 ± 0.8
19 ± 0.8
22.5 ± 1
22.5 ± 1
30 ± 1.5
30 ± 1.5
39 ± 1.5
39 ± 1.5
42.5 ± 2
42.5 ± 2
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
15.3
15.3
17.8
17.8
22.9
22.9
40.7
40.7
40.7
40.7
1.5
1.5
1.6
1.6
1.9
1.9
2.1
2.1
2.3
2.3
780
780
1160
1160
1950
1950
3230
3230
3950
3950
297
297
461
461
788
788
1241
1241
1518
1518
33.5 ±
1.5
33.5 ±
1.5
36.5 ±
1.5
36.5 ±
1.5
31.5 ±
1.5
31.5 ±
1.5
38.5 ±
1.5
38.5 ±
1.5
51.5 ±
2.5
51.5 ±
2.5
23 ± 1
23 ± 1
27 ± 1
27 ± 1
35 ± 1.5
35 ± 1.5
44.5 ± 2
44.5 ± 2
48.5 ± 2
48.5 ± 2
Electrical values instrumentation cables
Type
Capacitance, approx.
(nF/km)
Inductance, approx,
(mH/km)
Resistance at 20°C, max.
(Ohm/km)
L/R ratio,
(microH/Ohm)
Unshielded pair 0,75 mm²
55
0,94
26,3
17,9
Unshielded triple 0,75 mm²
55
0,94
26,3
17,9
Unshielded pair 1,5 mm²
65
0,89
12,9
32,6
Unshielded triple 1,5 mm²
65
0,89
12,9
32,6
Unshielded pair 2,5 mm²
75
0,77
8,02
48
Unshielded triple 2,5 mm²
75
0,77
8,02
48
Subject to change without prior notice
Page 152 of 212
Ordering information
New Part
number
Old Part
number
822906
822907
822918
822919
822930
822931
822936
822937
822942
822943
822948
822949
822966
822967
822978
822979
822990
822991
822996
822997
823002
823003
823008
823009
823306
823307
823318
823319
823330
823331
823336
823337
823342
823343
823348
823349
823366
823367
823378
823379
823390
823391
823396
823397
823402
823403
823408
823409
828506
828507
828518
828519
828530
828531
828536
828537
828542
828543
828548
828549
828566
828567
Description
BFOU-XFR(C) 2PAIR 0.75mm²
BFOU-XFR(C) 2PAIR 0.75mm²
BFOU-XFR(C) 4PAIR 0.75mm²
BFOU-XFR(C) 4PAIR 0.75mm²
BFOU-XFR(C) 8PAIR 0.75mm²
BFOU-XFR(C) 8PAIR 0.75mm²
BFOU-XFR(C) 12PAIR 0.75mm²
BFOU-XFR(C) 12PAIR 0.75mm²
BFOU-XFR(C) 16PAIR 0.75mm²
BFOU-XFR(C) 16PAIR 0.75mm²
BFOU-XFR(C) 24PAIR 0.75mm²
BFOU-XFR(C) 24PAIR 0.75mm²
BFOU-XFR(C) 2TRIP 0.75mm²
BFOU-XFR(C) 2TRIP 0.75mm²
BFOU-XFR(C) 4TRIP 0.75mm²
BFOU-XFR(C) 4TRIP 0.75mm²
BFOU-XFR(C) 8TRIP 0.75mm²
BFOU-XFR(C) 8TRIP 0.75mm²
BFOU-XFR(C) 12TRIP 0.75mm²
BFOU-XFR(C) 12TRIP 0.75mm²
BFOU-XFR(C) 16TRIP 0.75mm²
BFOU-XFR(C) 16TRIP 0.75mm²
BFOU-XFR(C) 24TRIP 0.75mm²
BFOU-XFR(C) 24TRIP 0.75mm²
BFOU-XFR(C) 2PAIR 1.5mm²
BFOU-XFR(C) 2PAIR 1.5mm²
BFOU-XFR(C) 4PAIR 1.5mm²
BFOU-XFR(C) 4PAIR 1.5mm²
BFOU-XFR(C) 8PAIR 1.5mm²
BFOU-XFR(C) 8PAIR 1.5mm²
BFOU-XFR(C) 12PAIR 1.5mm²
BFOU-XFR(C) 12PAIR 1.5mm²
BFOU-XFR(C) 16PAIR 1.5mm²
BFOU-XFR(C) 16PAIR 1.5mm²
BFOU-XFR(C) 24PAIR 1.5mm²
BFOU-XFR(C) 24PAIR 1.5mm²
BFOU-XFR(C) 2TRIP 1.5mm²
BFOU-XFR(C) 2TRIP 1.5mm²
BFOU-XFR(C) 4TRIP 1.5mm²
BFOU-XFR(C) 4TRIP 1.5mm²
BFOU-XFR(C) 8TRIP 1.5mm²
BFOU-XFR(C) 8TRIP 1.5mm²
BFOU-XFR(C) 12TRIP 1.5mm²
BFOU-XFR(C) 12TRIP 1.5mm²
BFOU-XFR(C) 16TRIP 1.5mm²
BFOU-XFR(C) 16TRIP 1.5mm²
BFOU-XFR(C) 24TRIP 1.5mm²
BFOU-XFR(C) 24TRIP 1.5mm²
BFOU-XFR(C) 2PAIR 2.5mm²
BFOU-XFR(C) 2PAIR 2.5mm²
BFOU-XFR(C) 4PAIR 2.5mm²
BFOU-XFR(C) 4PAIR 2.5mm²
BFOU-XFR(C) 8PAIR 2.5mm²
BFOU-XFR(C) 8PAIR 2.5mm²
BFOU-XFR(C) 12PAIR 2.5mm²
BFOU-XFR(C) 12PAIR 2.5mm²
BFOU-XFR(C) 16PAIR 2.5mm²
BFOU-XFR(C) 16PAIR 2.5mm²
BFOU-XFR(C) 24PAIR 2.5mm²
BFOU-XFR(C) 24PAIR 2.5mm²
BFOU-XFR(C) 2TRIP 2.5mm²
BFOU-XFR(C) 2TRIP 2.5mm²
Subject to change without prior notice
Sheath Colour
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
Stock item
-
EAN No. DNK
7021528229066
7021528229073
7021528229189
7021528229196
7021528229301
7021528229318
7021528229363
7021528229370
7021528229424
7021528229431
7021528229486
7021528229493
7021528229660
7021528229677
7021528229783
7021528229790
7021528229905
7021528229912
7021528229967
7021528229974
7021528230024
7021528230031
7021528230086
7021528230093
7021528233063
7021528233070
7021528233186
7021528233193
7021528233308
7021528233315
7021528233360
7021528233377
7021528233421
7021528233438
7021528233483
7021528233490
7021528233667
7021528233674
7021528233780
7021528233797
7021528233902
7021528233919
7021528233964
7021528233971
7021528234022
7021528234039
7021528234084
7021528234091
7021528285062
7021528285079
7021528285185
7021528285192
7021528285307
7021528285314
7021528285369
7021528285376
7021528285420
7021528285437
7021528285482
7021528285499
7021528285666
7021528285673
Page 153 of 212
EL No.
-
New Part
number
Old Part
number
828578
828579
828590
828591
828596
828597
828602
828603
Description
BFOU-XFR(C) 4TRIP 2.5mm²
BFOU-XFR(C) 4TRIP 2.5mm²
BFOU-XFR(C) 8TRIP 2.5mm²
BFOU-XFR(C) 8TRIP 2.5mm²
BFOU-XFR(C) 12TRIP 2.5mm²
BFOU-XFR(C) 12TRIP 2.5mm²
BFOU-XFR(C) 16TRIP 2.5mm²
BFOU-XFR(C) 16TRIP 2.5mm²
Sheath Colour
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
Stock item
-
EAN No. DNK
7021528285789
7021528285796
7021528285901
7021528285918
7021528285963
7021528285970
7021528286021
7021528286038
EL No.
-
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius
Fixed Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 154 of 212
eXtended Fire Resistant, instrumentation cable BFCU-XFR(i) 150/250(300)V, steel wire
braided
eXtended Fire Resistant, flame retardant
halogen-free instrumentation cable. Mud
resistant
BFCU-XFR(i)
150/250(300)V
MGT/EPR/EPR/GSWB/EVA
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation,
communication, control and alarm systems in both
EX- and safe areas, emergency and critical
systems where requirement for fire resistance
exists. Meets the mud resistant requirements in
NEK TS 606:2009.
Cables have extended fire resistant (XFR)
properties to IEC 60331-1&2 including water spray
according to EN 50200 Annex E (90 minutes).
IEC 60092-376 (2003-05)
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-1, -2
EN 50200:2006 Annex E
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Lay up /
Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped
with a PETP tape.
Flame retardant and halogen-free thermoplastic compound
PET tape + rubberized Polyamide tape
C
Galvanized steel wire braid
PET tape + rubberized Polyamide tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
Eg. "meter" "year" DRAKA 01 BFCU-XFR(I) 250V 4PAIR 1.5mm2 FLEX - FLAME
IEC 60092-376 EN 50200:2006 Annex E IEC 60331-1*) IEC 60331-2*) IEC 603323-22
DRAKA 01 = Draka Norsk Kabel
Grey or Blue
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
Subject to change without prior notice
Page 155 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
Thickness
Inner
covering,
mm
Diameter
inner
covering,
mm
1
2
0.75
1.1
1
1.1
9.5 ± 0.5 0.3
8.5
1.1
1
2
0.75
1.1
1
1.1
9.5 ± 0.5 0.3
8.5
1.1
2
2
0.75
1.1
1
1.1
0.3
11.9
1.3
2
2
0.75
1.1
1
1.1
0.3
11.9
1.3
4
4
8
8
12
12
2
2
2
2
2
2
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1
1
1
1
1
1
1.1
1.1
1.1
1.1
1.4
1.4
0.3
0.3
0.3
0.3
0.3
0.3
13.6
13.6
17.8
17.8
20.4
20.4
1.4
1.4
1.6
1.6
1.7
1.7
16
2
0.75
1.1
1
1.9
0.3
22.9
1.8
16
2
0.75
1.1
1
1.9
0.3
22.9
1.8
24
24
2
2
0.75
0.75
1.1
1.1
1
1
2.3
2.3
0.46
0.46
47.9
47.9
2.1
2.1
13.5 ±
0.8
13.5 ±
0.8
18.5 ±
0.8
18.5 ±
0.8
21.5 ± 1
21.5 ± 1
28 ± 1
28 ± 1
33 ± 1.5
33 ± 1.5
37.5 ±
1.5
37.5 ±
1.5
46.5 ± 2
46.5 ± 2
1
3
0.75
1.1
1
1.1
0.3
8.5
1.1
14 ± 0.8 330
24
1
3
0.75
1.1
1
1.1
0.3
8.5
1.1
14 ± 0.8 330
24
2
2
3
3
0.75
0.75
1.1
1.1
1
1
1.1
1.1
0.3
0.3
11.9
11.9
1.4
1.4
20 ± 1
20 ± 1
550
550
47
47
4
3
0.75
1.1
1
1.1
0.3
15.3
1.4
23 ± 1
780
93
4
3
0.75
1.1
1
1.1
0.3
15.3
1.4
23 ± 1
780
93
8
8
12
12
16
16
3
3
3
3
3
3
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1
1
1
1
1
1
1.1
1.1
1.4
1.4
2.1
2.1
10.5 ±
0.8
10.5 ±
0.8
16 ± 0.8
16 ± 0.8
18.5 ±
0.8
18.5 ±
0.8
25 ± 1
25 ± 1
31 ± 1.5
31 ± 1.5
36 ± 1.5
36 ± 1.5
0.3
0.3
0.3
0.3
0.3
0.3
20.4
20.4
22.9
22.9
25.4
25.4
1.7
1.7
1.8
1.8
1.9
1.9
1310
1310
1810
1810
2470
2470
186
186
279
279
371
371
24
3
0.75
1.1
1
2.5
45 ± 2
0.46
53.8
2.2
3770
557
24
3
0.75
1.1
1
2.5
45 ± 2
0.46
53.8
2.2
30 ± 1.5
30 ± 1.5
36 ± 1.5
36 ± 1.5
41.5 ± 2
41.5 ± 2
51.5 ±
2.5
51.5 ±
2.5
3770
557
1
2
1.5
1.6
1
1.1
0.3
8.5
1.2
350
34
1
2
1.5
1.6
1
1.1
0.3
8.5
1.2
350
34
2
2
4
4
8
8
2
2
2
2
2
2
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1
1
1
1
1
1
1.1
1.1
1.1
1.1
1.1
1.1
0.3
0.3
0.3
0.3
0.3
0.3
11.9
11.9
15.3
15.3
20.4
20.4
1.4
1.4
1.5
1.5
1.7
1.7
14.5 ±
0.8
14.5 ±
0.8
20.5 ± 1
20.5 ± 1
23.5 ± 1
23.5 ± 1
31 ± 1.5
31 ± 1.5
560
560
820
820
1360
1360
68
68
136
136
272
272
12
2
1.5
1.6
1
1.4
0.3
22.9
1.9
37 ± 1.5 1900
408
12
2
1.5
1.6
1
1.4
0.3
22.9
1.9
37 ± 1.5 1900
408
Subject to change without prior notice
14.5 ±
0.8
14.5 ±
0.8
17 ± 0.8
17 ± 0.8
23.5 ± 1
23.5 ± 1
28 ± 1
28 ± 1
32.5 ±
1.5
32.5 ±
1.5
40.5 ± 2
40.5 ± 2
10.5 ±
0.8
10.5 ±
0.8
16 ± 0.8
16 ± 0.8
19 ± 0.8
19 ± 0.8
26 ± 1
26 ± 1
31.5 ±
1.5
31.5 ±
Thickness
Outer
Sheath,
mm
Weight
Diameter
of
outer
Cable
sheath,
Approx.
mm
(Kg/Km)
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Copper
content
Approx.
(kg/km)
300
17
300
17
470
34
470
34
650
650
1060
1060
1450
1450
67
67
134
134
200
200
1920
267
1920
267
2980
2980
400
400
Page 156 of 212
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Weight
Diameter
of
outer
Cable
sheath,
Approx.
mm
(Kg/Km)
Copper
content
Approx.
(kg/km)
0.46
0.46
0.46
0.46
41.9
41.9
53.8
53.8
2.1
2.1
2.4
2.4
43 ± 2
43 ± 2
52 ± 2.5
52 ± 2.5
2750
2750
3880
3880
544
544
816
816
0.3
8.5
1.2
390
49
0.3
8.5
1.2
390
49
0.3
13.6
1.5
22 ± 1
680
97
0.3
13.6
1.5
22 ± 1
680
97
0.3
0.3
0.3
0.3
15.3
15.3
20.4
20.4
1.6
1.6
1.8
1.8
25.5 ± 1
25.5 ± 1
33 ± 1.5
33 ± 1.5
1000
1000
1680
1680
193
193
386
386
0.3
25.4
2
41 ± 2
2460
579
0.3
25.4
2
41 ± 2
2460
579
0.46
0.46
0.46
0.46
47.9
47.9
59.8
59.8
2.2
2.2
2.6
2.6
47.5 ± 2
47.5 ± 2
58 ± 2.5
58 ± 2.5
3510
3510
5080
5080
772
772
1157
1157
0.3
8.5
1.2
390
55
0.3
8.5
1.2
390
55
0.3
13.6
1.5
22 ± 1
660
109
0.3
13.6
1.5
22 ± 1
660
109
0.3
0.3
15.3
15.3
1.6
1.6
970
970
218
218
1.1
28.5 ± 1 0.3
20.4
1.8
1620
435
1
1.1
28.5 ± 1 0.3
20.4
1.8
1620
435
2
2
2
2
1
1
1
1
2.3
2.3
2.3
2.3
36 ± 1.5
36 ± 1.5
40.5 ± 2
40.5 ± 2
0.3
0.3
0.46
0.46
25.4
25.4
47.9
47.9
2
2
2.2
2.2
25.5 ± 1
25.5 ± 1
33.5 ±
1.5
33.5 ±
1.5
41.5 ± 2
41.5 ± 2
46.5 ± 2
46.5 ± 2
2550
2550
3370
3370
652
652
869
869
2.5
2.5
2.5
2.5
2.5
2.5
2
2
2
2
2
2
1
1
1
1
1
1
1.1
1.1
1.1
1.1
1.1
1.1
0.3
0.3
0.3
0.3
0.3
0.3
10.2
10.2
15.3
15.3
17.8
17.8
1.2
1.2
1.5
1.5
1.6
1.6
16 ± 0.8
16 ± 0.8
23.5 ± 1
23.5 ± 1
27.5 ± 1
27.5 ± 1
450
450
790
790
1200
1200
78
78
155
155
310
310
3
2.5
2
1
1.3
0.3
22.9
2
36 ± 1.5 2120
619
8
3
2.5
2
1
1.3
0.3
22.9
2
36 ± 1.5 2120
619
12
12
3
3
2.5
2.5
2
2
1
1
2.6
2.6
12 ± 0.8
12 ± 0.8
19 ± 0.8
19 ± 0.8
22.5 ± 1
22.5 ± 1
30.5 ±
1.5
30.5 ±
1.5
40.5 ± 2
40.5 ± 2
0.46
0.46
47.9
47.9
2.2
2.2
47 ± 2
47 ± 2
929
929
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
Diameter
inner
covering,
mm
16
16
24
24
2
2
2
2
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1
1
1
1
2.1
2.1
2.3
2.3
1.5
37 ± 1.5
37 ± 1.5
45.5 ± 2
45.5 ± 2
1
3
1.5
1.6
1
1.1
1
3
1.5
1.6
1
1.1
2
3
1.5
1.6
1
1.1
2
3
1.5
1.6
1
1.1
4
4
8
8
3
3
3
3
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1
1
1
1
1.1
1.1
1.1
1.1
12
3
1.5
1.6
1
1.6
12
3
1.5
1.6
1
1.6
16
16
24
24
3
3
3
3
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1
1
1
1
2.3
2.3
2.7
2.7
1
2
2.5
2
1
1.1
1
2
2.5
2
1
1.1
2
2
2.5
2
1
1.1
2
2
2.5
2
1
1.1
4
4
2
2
2.5
2.5
2
2
1
1
1.1
1.1
11.5 ±
0.8
11.5 ±
0.8
17.5 ±
0.8
17.5 ±
0.8
20.5 ± 1
20.5 ± 1
8
2
2.5
2
1
8
2
2.5
2
12
12
16
16
2
2
2
2
2.5
2.5
2.5
2.5
1
1
2
2
4
4
3
3
3
3
3
3
8
Subject to change without prior notice
11.5 ±
0.8
11.5 ±
0.8
17.5 ±
0.8
17.5 ±
0.8
21 ± 1
21 ± 1
28 ± 1
28 ± 1
35.5 ±
1.5
35.5 ±
1.5
41 ± 2
41 ± 2
51 ± 2.5
51 ± 2.5
15.5 ±
0.8
15.5 ±
0.8
15.5 ±
0.8
15.5 ±
0.8
3520
3520
Page 157 of 212
Electrical values instrumentation cables
Type
Capacitance, approx.
(nF/km)
Inductance, approx,
(mH/km)
Resistance at 20°C, max.
(Ohm/km)
L/R ratio,
(microH/Ohm)
Shielded pair 0,75 mm²
Shielded triple 0,75 mm²
65
65
0,94
0,94
26,3
26,3
17,9
17,9
Shielded pair 1,5 mm²
Shielded triple 1,5 mm²
80
80
0,84
0,84
12,9
12,9
32,6
32,6
Shielded pair 2,5 mm²
Shielded triple 2,5 mm²
100
100
0,77
0,77
8,02
8,02
48
48
Ordering information
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
821000
821001
821006
821007
821018
821019
821030
821031
821036
821037
821042
821043
821048
821049
BFCU-XFR(I) 1PAIR 0.75mm²
BFCU-XFR(I) 1PAIR 0.75mm²
BFCU-XFR(I) 2PAIR 0.75mm²
BFCU-XFR(I) 2PAIR 0.75mm²
BFCU-XFR(I) 4PAIR 0.75mm²
BFCU-XFR(I) 4PAIR 0.75mm²
BFCU-XFR(I) 8PAIR 0.75mm²
BFCU-XFR(I) 8PAIR 0.75mm²
BFCU-XFR(I) 12PAIR 0.75mm²
BFCU-XFR(I) 12PAIR 0.75mm²
BFCU-XFR(I) 16PAIR 0.75mm²
BFCU-XFR(I) 16PAIR 0.75mm²
BFCU-XFR(I) 24PAIR 0.75mm²
BFCU-XFR(I) 24PAIR 0.75mm²
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528210002
7021528210019
7021528210064
7021528210071
7021528210187
7021528210194
7021528210309
7021528210316
7021528210361
7021528210378
7021528210422
7021528210439
7021528210484
7021528210491
-
821060
821061
821066
821067
821078
821079
821090
821091
821096
821097
821102
821103
821108
821109
BFCU-XFR(I) 1TRIP 0.75mm²
BFCU-XFR(I) 1TRIP 0.75mm²
BFCU-XFR(I) 2TRIP 0.75mm²
BFCU-XFR(I) 2TRIP 0.75mm²
BFCU-XFR(I) 4TRIP 0.75mm²
BFCU-XFR(I) 4TRIP 0.75mm²
BFCU-XFR(I) 8TRIP 0.75mm²
BFCU-XFR(I) 8TRIP 0.75mm²
BFCU-XFR(I) 12TRIP 0.75mm²
BFCU-XFR(I) 12TRIP 0.75mm²
BFCU-XFR(I) 16TRIP 0.75mm²
BFCU-XFR(I) 16TRIP 0.75mm²
BFCU-XFR(I) 24TRIP 0.75mm²
BFCU-XFR(I) 24TRIP 0.75mm²
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528210606
7021528210613
7021528210668
7021528210675
7021528210781
7021528210798
7021528210903
7021528210910
7021528210965
7021528210972
7021528211023
7021528211030
7021528211085
7021528211092
-
821400
821401
821406
821407
821418
821419
821430
821431
821436
821437
821442
821443
821448
821449
BFCU-XFR(I) 1PAIR 1.5mm²
BFCU-XFR(I) 1PAIR 1.5mm²
BFCU-XFR(I) 2PAIR 1.5mm²
BFCU-XFR(I) 2PAIR 1.5mm²
BFCU-XFR(I) 4PAIR 1.5mm²
BFCU-XFR(I) 4PAIR 1.5mm²
BFCU-XFR(I) 8PAIR 1.5mm²
BFCU-XFR(I) 8PAIR 1.5mm²
BFCU-XFR(I) 12PAIR 1.5mm²
BFCU-XFR(I) 12PAIR 1.5mm²
BFCU-XFR(I) 16PAIR 1.5mm²
BFCU-XFR(I) 16PAIR 1.5mm²
BFCU-XFR(I) 24PAIR 1.5mm²
BFCU-XFR(I) 24PAIR 1.5mm²
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528214000
7021528214017
7021528214062
7021528214079
7021528214185
7021528214192
7021528214307
7021528214314
7021528214369
7021528214376
7021528214420
7021528214437
7021528214482
7021528214499
-
GREY
BLUE
GREY
-
7021528214604
7021528214611
7021528214666
-
821460 BFCU-XFR(I) 1TRIP 1.5mm²
821461 BFCU-XFR(I) 1TRIP 1.5mm²
821466 BFCU-XFR(I) 2TRIP 1.5mm²
Subject to change without prior notice
Page 158 of 212
New Part
number
Old Part
number
821467
821478
821479
821490
821491
821496
821497
821502
821503
821508
821509
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
BFCU-XFR(I) 2TRIP 1.5mm²
BFCU-XFR(I) 4TRIP 1.5mm²
BFCU-XFR(I) 4TRIP 1.5mm²
BFCU-XFR(I) 8TRIP 1.5mm²
BFCU-XFR(I) 8TRIP 1.5mm²
BFCU-XFR(I) 12TRIP 1.5mm²
BFCU-XFR(I) 12TRIP 1.5mm²
BFCU-XFR(I) 16TRIP 1.5mm²
BFCU-XFR(I) 16TRIP 1.5mm²
BFCU-XFR(I) 24TRIP 1.5mm²
BFCU-XFR(I) 24TRIP 1.5mm²
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528214673
7021528214789
7021528214796
7021528214901
7021528214918
7021528214963
7021528214970
7021528215021
7021528215038
7021528215083
7021528215090
-
828700
828701
828706
828707
828718
828719
828730
828731
828736
828737
828742
828743
BFCU-XFR(I) 1PAIR 2.5mm²
BFCU-XFR(I) 1PAIR 2.5mm²
BFCU-XFR(I) 2PAIR 2.5mm²
BFCU-XFR(I) 2PAIR 2.5mm²
BFCU-XFR(I) 4PAIR 2.5mm²
BFCU-XFR(I) 4PAIR 2.5mm²
BFCU-XFR(I) 8PAIR 2.5mm²
BFCU-XFR(I) 8PAIR 2.5mm²
BFCU-XFR(I) 12PAIR 2.5mm²
BFCU-XFR(I) 12PAIR 2.5mm²
BFCU-XFR(I) 16PAIR 2.5mm²
BFCU-XFR(I) 16PAIR 2.5mm²
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528287004
7021528287011
7021528287066
7021528287073
7021528287189
7021528287196
7021528287301
7021528287318
7021528287363
7021528287370
7021528287424
7021528287431
-
828760
828761
828766
828767
828778
828779
828790
828791
828796
828797
BFCU-XFR(I) 1TRIP 2.5mm²
BFCU-XFR(I) 1TRIP 2.5mm²
BFCU-XFR(I) 2TRIP 2.5mm²
BFCU-XFR(I) 2TRIP 2.5mm²
BFCU-XFR(I) 4TRIP 2.5mm²
BFCU-XFR(I) 4TRIP 2.5mm²
BFCU-XFR(I) 8TRIP 2.5mm²
BFCU-XFR(I) 8TRIP 2.5mm²
BFCU-XFR(I) 12TRIP 2.5mm²
BFCU-XFR(I) 12TRIP 2.5mm²
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528287608
7021528287615
7021528287660
7021528287677
7021528287783
7021528287790
7021528287905
7021528287912
7021528287967
7021528287974
-
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius
Fixed Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 159 of 212
eXtended Fire Resistant, instrumentation cable BFCU-XFR(c) 150/250(300)V, steel wire
braided
eXtended Fire Resistant, flame retardant
halogen-free instrumentation cable. Mud
resistant
BFCU-XFR(c)
150/250(300)V
MGT/EPR/EPR/GSWB/EVA
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation,
communication, control and alarm systems in both
EX- and safe areas, emergency and critical systems
where requirement for fire resistance exists. Meets
the mud resistant requirements in NEK TS 606:2009.
Cables have extended fire resistant (XFR) properties
to IEC 60331-1&2 including water spray according to
EN 50200 Annex E (90 minutes).
IEC 60092-376 (2003-05)
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-1, -2
EN 50200:2006 Annex E
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
Flame retardant and halogen-free thermoplastic compound
PET tape + rubberized Polyamide tape
C
Galvanized steel wire braid
PET tape + rubberized Polyamide tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
Eg. "meter" "year" DRAKA 01 BFCU-XFR(C) 250V 4PAIR 1.5mm2 FLEX - FLAME
IEC 60092-376 EN 50200:2006 Annex E IEC 60331-1*) or IEC 60331-2*) IEC
60332-3-22
DRAKA 01 = Draka Norsk Kabel
Grey or Blue
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
Subject to change without prior notice
Page 160 of 212
Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Weight
Diameter
of
outer
Cable
sheath,
Approx.
mm
(Kg/Km)
Copper
content
Approx.
(kg/km)
0.3
0.3
10.2
10.2
1.3
1.3
18 ± 0.8 440
18 ± 0.8 440
30
30
0.3
11.9
1.3
20.5 ± 1 580
56
0.3
11.9
1.3
20.5 ± 1 580
56
0.3
0.3
0.3
0.3
17.8
17.8
20.4
20.4
1.5
1.5
1.6
1.6
960
960
1290
1290
107
107
159
159
1.9
29.5 ± 1 0.3
22.9
1.7
1680
210
1
1.9
29.5 ± 1 0.3
22.9
1.7
26.5 ± 1
26.5 ± 1
31 ± 1.5
31 ± 1.5
34.5 ±
1.5
34.5 ±
1.5
1680
210
1.1
1
2.3
0.46
41.9
2
42.5 ± 2 2550
313
0.75
1.1
1
2.3
0.46
41.9
2
42.5 ± 2 2550
313
3
3
0.75
0.75
1.1
1.1
1
1
1.1
1.1
0.3
0.3
11.9
11.9
1.3
1.3
20 ± 1
20 ± 1
530
530
43
43
4
3
0.75
1.1
1
1.1
0.3
15.3
1.4
23 ± 1
750
82
4
3
0.75
1.1
1
1.1
0.3
15.3
1.4
23 ± 1
750
82
8
8
12
12
16
16
24
24
3
3
3
3
3
3
3
3
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1
1
1
1
1
1
1
1
1.1
1.1
1.4
1.4
2.1
2.1
2.5
2.5
0.3
0.3
0.3
0.3
0.3
0.3
0.46
0.46
17.8
17.8
22.9
22.9
25.4
25.4
47.9
47.9
1.6
1.6
1.7
1.7
1.8
1.8
2.1
2.1
29.5 ± 1
29.5 ± 1
35 ± 1.5
35 ± 1.5
39 ± 1.5
39 ± 1.5
48.5 ± 2
48.5 ± 2
1210
1210
1670
1670
2220
2220
3370
3370
159
159
237
237
314
314
469
469
2
2
1.5
1.6
1
1.1
0.3
11.9
1.4
20 ± 1
540
62
2
2
1.5
1.6
1
1.1
0.3
11.9
1.4
20 ± 1
540
62
4
2
1.5
1.6
1
1.1
0.3
15.3
1.4
22.5 ± 1 750
118
4
2
1.5
1.6
1
1.1
0.3
15.3
1.4
22.5 ± 1 750
118
8
8
2
2
1.5
1.5
1.6
1.6
1
1
1.1
1.1
15.5 ±
0.8
15.5 ±
0.8
18.5 ±
0.8
18.5 ±
0.8
25 ± 1
25 ± 1
0.3
0.3
17.8
17.8
1.7
1.7
1220
1220
230
230
12
2
1.5
1.6
1
1.4
29.5 ± 1 0.3
22.9
1.8
1670
342
12
2
1.5
1.6
1
1.4
29.5 ± 1 0.3
22.9
1.8
1670
342
16
2
1.5
1.6
1
1.9
33 ± 1.5 0.3
25.4
1.9
2160
454
16
2
1.5
1.6
1
1.9
33 ± 1.5 0.3
25.4
1.9
2160
454
24
24
2
2
1.5
1.5
1.6
1.6
1
1
2.3
2.3
41 ± 2
41 ± 2
47.9
47.9
2.2
2.2
30 ± 1.5
30 ± 1.5
34.5 ±
1.5
34.5 ±
1.5
38.5 ±
1.5
38.5 ±
1.5
47.5 ± 2
47.5 ± 2
3290
3290
678
678
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
Diameter
inner
covering,
mm
2
2
2
2
0.75
0.75
1.1
1.1
1
1
1.1
1.1
4
2
0.75
1.1
1
1.1
4
2
0.75
1.1
1
1.1
8
8
12
12
2
2
2
2
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1
1
1
1
1.1
1.1
1.4
1.4
14 ± 0.8
14 ± 0.8
16.5 ±
0.8
16.5 ±
0.8
22 ± 1
22 ± 1
26.5 ± 1
26.5 ± 1
16
2
0.75
1.1
1
16
2
0.75
1.1
24
2
0.75
24
2
2
2
Subject to change without prior notice
36.5 ±
1.5
36.5 ±
1.5
16 ± 0.8
16 ± 0.8
18.5 ±
0.8
18.5 ±
0.8
25 ± 1
25 ± 1
30 ± 1.5
30 ± 1.5
34 ± 1.5
34 ± 1.5
42.5 ± 2
42.5 ± 2
0.46
0.46
Page 161 of 212
Mechanical
Diameter
crossBraid
section of
Wire,
the braid,
mm
mm²
Thickness
Outer
Sheath,
mm
Weight
Diameter
of
outer
Cable
sheath,
Approx.
mm
(Kg/Km)
Copper
content
Approx.
(kg/km)
0.3
13.6
1.4
22 ± 1
660
91
0.3
13.6
1.4
22 ± 1
660
91
0.3
0.3
0.3
0.3
0.3
0.3
15.3
15.3
20.4
20.4
25.4
25.4
1.5
1.5
1.8
1.8
1.9
1.9
25.5 ± 1
25.5 ± 1
33 ± 1.5
33 ± 1.5
39 ± 1.5
39 ± 1.5
930
930
1580
1580
2190
2190
175
175
344
344
512
512
0.46
41.9
2.1
44.5 ± 2 3130
681
0.46
41.9
2.1
44.5 ± 2 3130
681
2.7
47.5 ± 2 0.46
53.8
2.4
1
2.7
47.5 ± 2 0.46
53.8
2.4
2
2
1
1
1.1
1.1
0.3
0.3
13.6
13.6
1.4
1.4
2.5
2
1
1.1
0.3
15.3
2
2.5
2
1
1.1
0.3
8
8
2
2
2.5
2.5
2
2
1
1
1.1
1.1
12
2
2.5
2
1
2.1
12
2
2.5
2
1
2.1
16
2
2.5
2
1
2.3
16
2
2.5
2
1
2.3
24
24
2
2
2.5
2.5
2
2
1
1
2.7
2.7
17 ± 0.8
17 ± 0.8
19.5 ±
0.8
19.5 ±
0.8
27 ± 1
27 ± 1
33.5 ±
1.5
33.5 ±
1.5
36.5 ±
1.5
36.5 ±
1.5
45 ± 2
45 ± 2
2
2
4
4
3
3
3
3
2.5
2.5
2.5
2.5
2
2
2
2
1
1
1
1
1.1
1.1
1.1
1.1
19 ± 0.8
19 ± 0.8
22.5 ± 1
22.5 ± 1
8
3
2.5
2
1
8
3
2.5
2
12
12
16
16
3
3
3
3
2.5
2.5
2.5
2.5
2
2
2
2
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
2
3
1.5
1.6
1
1.1
2
3
1.5
1.6
1
1.1
4
4
8
8
12
12
3
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1
1
1
1
1
1
1.1
1.1
1.1
1.1
1.4
1.4
16
3
1.5
1.6
1
2.3
16
3
1.5
1.6
1
2.3
24
3
1.5
1.6
1
24
3
1.5
1.6
2
2
2
2
2.5
2.5
4
2
4
Subject to change without prior notice
Diameter
inner
covering,
mm
17.5 ±
0.8
17.5 ±
0.8
21 ± 1
21 ± 1
28 ± 1
28 ± 1
34 ± 1.5
34 ± 1.5
38.5 ±
1.5
38.5 ±
1.5
54.5 ±
2.5
54.5 ±
2.5
4500
1018
4500
1018
21 ± 1
21 ± 1
620
620
101
101
1.5
24 ± 1
880
193
15.3
1.5
24 ± 1
880
193
0.3
0.3
20.4
20.4
1.8
1.8
1480
1480
378
378
0.3
25.4
1.9
2220
562
0.3
25.4
1.9
32 ± 1.5
32 ± 1.5
38.5 ±
1.5
38.5 ±
1.5
2220
562
0.46
41.9
2.1
42.5 ± 2 2920
746
0.46
41.9
2.1
42.5 ± 2 2920
746
0.46
0.46
53.8
53.8
2.4
2.4
52 ± 2.5 4190
52 ± 2.5 4190
1114
1114
0.3
0.3
0.3
0.3
15.3
15.3
17.8
17.8
1.5
1.5
1.6
1.6
780
780
1160
1160
148
148
286
286
1.1
30 ± 1.5 0.3
22.9
1.9
1940
564
1
1.1
30 ± 1.5 0.3
22.9
1.9
1940
564
1
1
1
1
2.6
2.6
2.6
2.6
39 ± 1.5
39 ± 1.5
42.5 ± 2
42.5 ± 2
47.9
47.9
47.9
47.9
2.1
2.1
2.3
2.3
23.5 ± 1
23.5 ± 1
27 ± 1
27 ± 1
35.5 ±
1.5
35.5 ±
1.5
45.5 ± 2
45.5 ± 2
49 ± 2
49 ± 2
3280
3280
3980
3980
842
842
1119
1119
0.46
0.46
0.46
0.46
Page 162 of 212
Electrical values instrumentation cables
Type
Capacitance, approx.
(nF/km)
Inductance, approx,
(mH/km)
Resistance at 20°C, max.
(Ohm/km)
L/R ratio,
(microH/Ohm)
Unshielded pair 0,75 mm²
55
0,94
26,3
17,9
Unshielded triple 0,75 mm²
55
0,94
26,3
17,9
Unshielded pair 1,5 mm²
65
0,89
12,9
32,6
Unshielded triple 1,5 mm²
65
0,89
12,9
32,6
Unshielded pair 2,5 mm²
75
0,77
8,02
48
Unshielded triple 2,5 mm²
75
0,77
8,02
48
Ordering information
New Part
number
Old Part
number
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
821606
821607
821618
821619
821630
821631
821636
821637
821642
821643
821648
821649
BFCU-XFR(C) 2PAIR 0.75mm²
BFCU-XFR(C) 2PAIR 0.75mm²
BFCU-XFR(C) 4PAIR 0.75mm²
BFCU-XFR(C) 4PAIR 0.75mm²
BFCU-XFR(C) 8PAIR 0.75mm²
BFCU-XFR(C) 8PAIR 0.75mm²
BFCU-XFR(C) 12PAIR 0.75mm²
BFCU-XFR(C) 12PAIR 0.75mm²
BFCU-XFR(C) 16PAIR 0.75mm²
BFCU-XFR(C) 16PAIR 0.75mm²
BFCU-XFR(C) 24PAIR 0.75mm²
BFCU-XFR(C) 24PAIR 0.75mm²
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528216066
7021528216073
7021528216189
7021528216196
7021528216301
7021528216318
7021528216363
7021528216370
7021528216424
7021528216431
7021528216486
7021528216493
-
821666
821667
821678
821679
821690
821691
821696
821697
821702
821703
821708
821709
BFCU-XFR(C) 2TRIP 0.75mm²
BFCU-XFR(C) 2TRIP 0.75mm²
BFCU-XFR(C) 4TRIP 0.75mm²
BFCU-XFR(C) 4TRIP 0.75mm²
BFCU-XFR(C) 8TRIP 0.75mm²
BFCU-XFR(C) 8TRIP 0.75mm²
BFCU-XFR(C) 12TRIP 0.75mm²
BFCU-XFR(C) 12TRIP 0.75mm²
BFCU-XFR(C) 16TRIP 0.75mm²
BFCU-XFR(C) 16TRIP 0.75mm²
BFCU-XFR(C) 24TRIP 0.75mm²
BFCU-XFR(C) 24TRIP 0.75mm²
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528216660
7021528216677
7021528216783
7021528216790
7021528216905
7021528216912
7021528216967
7021528216974
7021528217025
7021528217032
7021528217087
7021528217094
-
822006
822007
822018
822019
822030
822031
822036
822037
822042
822043
822048
822049
BFCU-XFR(C) 2PAIR 1.5mm²
BFCU-XFR(C) 2PAIR 1.5mm²
BFCU-XFR(C) 4PAIR 1.5mm²
BFCU-XFR(C) 4PAIR 1.5mm²
BFCU-XFR(C) 8PAIR 1.5mm²
BFCU-XFR(C) 8PAIR 1.5mm²
BFCU-XFR(C) 12PAIR 1.5mm²
BFCU-XFR(C) 12PAIR 1.5mm²
BFCU-XFR(C) 16PAIR 1.5mm²
BFCU-XFR(C) 16PAIR 1.5mm²
BFCU-XFR(C) 24PAIR 1.5mm²
BFCU-XFR(C) 24PAIR 1.5mm²
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528220063
7021528220070
7021528220186
7021528220193
7021528220308
7021528220315
7021528220360
7021528220377
7021528220421
7021528220438
7021528220483
7021528220490
-
822066
822067
822078
822079
822090
822091
822096
822097
BFCU-XFR(C) 2TRIP 1.5mm²
BFCU-XFR(C) 2TRIP 1.5mm²
BFCU-XFR(C) 4TRIP 1.5mm²
BFCU-XFR(C) 4TRIP 1.5mm²
BFCU-XFR(C) 8TRIP 1.5mm²
BFCU-XFR(C) 8TRIP 1.5mm²
BFCU-XFR(C) 12TRIP 1.5mm²
BFCU-XFR(C) 12TRIP 1.5mm²
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528220667
7021528220674
7021528220780
7021528220797
7021528220902
7021528220919
7021528220964
7021528220971
-
Subject to change without prior notice
Page 163 of 212
New Part
number
Old Part
number
822102
822103
822108
822109
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
BFCU-XFR(C) 16TRIP 1.5mm²
BFCU-XFR(C) 16TRIP 1.5mm²
BFCU-XFR(C) 24TRIP 1.5mm²
BFCU-XFR(C) 24TRIP 1.5mm²
GREY
BLUE
GREY
BLUE
-
7021528221022
7021528221039
7021528221084
7021528221091
-
829106
829107
829118
829119
829130
829131
829136
829137
829142
829143
829148
829149
BFCU-XFR(C) 2PAIR 2.5mm²
BFCU-XFR(C) 2PAIR 2.5mm²
BFCU-XFR(C) 4PAIR 2.5mm²
BFCU-XFR(C) 4PAIR 2.5mm²
BFCU-XFR(C) 8PAIR 2.5mm²
BFCU-XFR(C) 8PAIR 2.5mm²
BFCU-XFR(C) 12PAIR 2.5mm²
BFCU-XFR(C) 12PAIR 2.5mm²
BFCU-XFR(C) 16PAIR 2.5mm²
BFCU-XFR(C) 16PAIR 2.5mm²
BFCU-XFR(C) 24PAIR 2.5mm²
BFCU-XFR(C) 24PAIR 2.5mm²
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528291063
7021528291070
7021528291186
7021528291193
7021528291308
7021528291315
7021528291360
7021528291377
7021528291421
7021528291438
7021528291483
7021528291490
-
829166
829167
829178
829179
829190
829191
829196
829197
829202
829203
BFCU-XFR(C) 2TRIP 2.5mm²
BFCU-XFR(C) 2TRIP 2.5mm²
BFCU-XFR(C) 4TRIP 2.5mm²
BFCU-XFR(C) 4TRIP 2.5mm²
BFCU-XFR(C) 8TRIP 2.5mm²
BFCU-XFR(C) 8TRIP 2.5mm²
BFCU-XFR(C) 12TRIP 2.5mm²
BFCU-XFR(C) 12TRIP 2.5mm²
BFCU-XFR(C) 16TRIP 2.5mm²
BFCU-XFR(C) 16TRIP 2.5mm²
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
-
7021528291667
7021528291674
7021528291780
7021528291797
7021528291902
7021528291919
7021528291964
7021528291971
7021528292022
7021528292039
-
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius
Fixed Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 164 of 212
Hydraulic and Turbine oils resistant, instrumentation cable BFOV(i) 150/250(300)V
Fire resistant, flame retardant halogen-free
instrumentation cable. Resistant to turbine and
hydraulic oils.
BFOV(i)
150/250(300)V
MGT/EPR/EPR/TCWB/EVA
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation, communication,
control and alarm systems in both EX- and safe areas,
emergency and critical systems where requirement for
fire resistance exists.
Especially resistant to the following hydraulic oils:
HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco
Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32.
IEC 60092-376 (2003-05)
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-1, -2, -21
IEC 600754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Lay up /
Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Outer sheath
colour
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and
wrapped with a PETP tape.
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned annealed copper wire braid
PET tape
V
Flame retardant, halogen-free and oil resistant thermoset compound (Therban),
SHF2 (IEC 60092-360)
Eg. "meter" "year" DRAKA NORSK KABEL BFOV(i) 250V 16 PAIR 0,75 mm2 FLEX
- FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC
60332-3-22
Grey or Blue
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
**) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes
Subject to change without prior notice
Page 165 of 212
Core identification instrumentation cables
Pair
Black - Light Blue
Triple
Black - Light Blue - Brown
Quad
Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
Diameter
inner
covering,
mm
Diameter
Braid
Wire,
mm
Thickness
Outer
Sheath,
mm
1
2
0.75
1.1
0.6
1.1
7.5 ± 0.5 0.2
1.1
1
2
0.75
1.1
0.6
1.1
7.5 ± 0.5 0.2
1.1
4
2
0.75
1.1
0.6
1.1
12.5 ±
0.8
0.3
1.4
1
3
0.75
1.1
0.6
1.1
8 ± 0.5
0.2
1.1
4
3
0.75
1.1
0.6
1.1
14 ± 0.8
0.3
1.4
8
3
0.75
1.1
0.6
1.1
0.3
1.7
12
3
0.75
1.1
0.6
1.4
18.5 ±
0.8
22.5 ± 1
0.3
1
2
1.5
1.6
0.7
1.1
9 ± 0.5
1
3
1.5
1.6
0.7
1.1
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
200
54
200
54
490
183
220
70
570
209
23 ± 1
960
359
1.8
27.5 ± 1
1290
475
0.2
1.1
12 ± 0.8
250
79
9.5 ± 0.5 0.2
1.2
12.5 ±
0.8
285
93
10.5 ±
0.8
10.5 ±
0.8
16.5 ±
0.8
11 ± 0.8
17.5 ±
0.8
Electrical values instrumentation cables
Capacitance, approx.
(nF/km)
Shielded pair 0,75 mm²
110
Shielded triple 0,75 mm²
110
Shielded pair 1,5 mm²
125
Shielded triple 1,5 mm²
125
Shielded pair 2,5 mm²
145
Shielded triple 2,5 mm²
145
Shielded 16 and 24 triple 1,5 mm²
105
Shielded 16 pair 2,5 mm²
110
Type
Inductance, approx,
(mH/km)
0,67
0,67
0,63
0,63
0,59
0,59
0,71
0,66
Resistance at 20°C, max.
(Ohm/km)
26,3
26,3
12,9
12,9
8,02
8,02
12,9
8,02
L/R ratio,
(microH/Ohm)
12,7
12,7
24,4
24,4
36,8
36,8
24,4
41,1
Ordering information
New Part
number
Old Part
number
20114120
20114414
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
BFOV(I) 1PAIR 0.75mm²
BFOV(I) 1PAIR 0.75mm²
BFOV(I) 4PAIR 0.75mm²
GREY
BLUE
GREY
Yes
Yes
-
7021528866643
7021528872507
7021528867060
-
886665
BFOV(I) 1TRIP 0.75mm²
BFOV(I) 4TRIP 0.75mm²
BFOV(I) 8TRIP 0.75mm²
BFOV(I) 12TRIP 0.75mm²
GREY
GREY
GREY
BLUE
-
7021528866650
7021528872521
7021528872538
7021528873054
-
886663
BFOV(I) 1PAIR 1.5mm²
GREY
-
7021528866636
-
886447
BFOV(I) 1TRIP 1.5mm²
GREY
-
7021528864472
-
886706
20110587
20114116
20115141
Other no. of pairs/triples and cross sectional area are available on request
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius
Fixed Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 166 of 212
Hydraulic and Turbine oils resistant, instrumentation cable BFOV(c) 150/250(300)V
Fire resistant, flame retardant halogen-free
instrumentation cable. Resistant to turbine and
hydraulic oils.
BFOV(c)
150/250(300)V
MGT/EPR/EPR/TCWB/HNBR
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation, communication,
control and alarm systems in both EX- and safe areas,
emergency and critical systems where requirement for
fire resistance exists.
Especially resistant to the following hydraulic oils:
HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco
Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32.
IEC 60092-376 (2003-05)
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-1, -2, -21
IEC 600754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned annealed copper wire braid
PET tape
U
Flame retardant, halogen-free and oil resistant thermoset compound (Therban),
SHF2 (IEC 60092-360)
Eg. "meter" "year" DRAKA NORSK KABEL BFOV(c) 250V 4 PAIR 0,75 mm2 FLEX
- FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC
60332-3-22
Grey or Blue
Marking text
Outer sheath
colour
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
**) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes
Subject to change without prior notice
Page 167 of 212
Core identification instrumentation cables
Pair
Black - Light Blue
Triple
Black - Light Blue - Brown
Quad
Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm²
Thickness
Inner
covering,
mm
2
2
0.75
1.1
0.6
1.1
4
2
0.75
1.1
0.6
1.1
4
2
0.75
1.1
0.6
1.1
8
2
0.75
1.1
0.6
1.1
8
2
0.75
1.1
0.6
1.1
12
2
0.75
1.1
0.6
8
3
0.75
1.1
0.6
1.1
8
3
0.75
1.1
0.6
1.1
2
2
1.5
1.6
0.7
1.1
4
4
8
2
2
2
1.5
1.5
1.5
1.6
1.6
1.6
0.7
0.7
0.7
8
3
1.5
1.6
0.7
1.1
Diameter
inner
covering,
mm
Diameter
Braid
Wire,
mm
Thickness
Outer
Sheath,
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
0.3
1.3
14.5 ±
0.8
340
113
0.3
1.3
16 ± 0.8
440
155
0.3
1.3
16 ± 0.8
440
155
0.3
1.5
20.5 ± 1
680
240
0.3
1.5
20.5 ± 1
680
240
0.3
1.6
23 ± 1
870
308
0.3
1.6
23 ± 1
870
308
13 ± 0.8
0.3
1.4
16.5 ±
0.8
440
162
22.5 ± 1
0.3
1.8
27 ± 1
1270
517
10.5 ±
0.8
12.5 ±
0.8
12.5 ±
0.8
16.5 ±
0.8
16.5 ±
0.8
18.5 ±
0.8
18.5 ±
0.8
Electrical values instrumentation cables
Type
Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm)
Unshielded pair 0,75 mm²
Unshielded triple 0,75 mm²
100
100
0,67
0,67
26,3
26,3
12,7
12,7
Unshielded pair 1,5 mm²
Unshielded triple 1,5 mm²
110
110
0,63
0,63
12,9
12,9
24,4
24,4
Unshielded pair 2,5 mm²
Unshielded triple 2,5 mm²
125
125
0,59
0,59
8,02
8,02
36,8
36,8
Unshielded 16 and 24 pair 2,5 mm²
Unshielded 16 triple 2,5 mm²
95
95
0,66
0,66
8,02
8,02
41,1
41,1
Ordering information
New Part
number
Old Part
number
887204
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
20114046
20115142
20115143
BFOV(C) 2PAIR 0.75mm²
BFOV(C) 4PAIR 0.75mm²
BFOV(C) 4PAIR 0.75mm²
BFOV(C) 8PAIR 0.75mm²
BFOV(C) 8PAIR 0.75mm²
BFOV(C) 12PAIR 0.75mm²
GREY
GREY
BLUE
GREY
BLUE
BLUE
Yes
-
7021528872040
7021528872514
7021528867695
7021528872545
7021528873023
7021528873030
-
20113991
20115144
BFOV(C) 8TRIP 0.75mm²
BFOV(C) 8TRIP 0.75mm²
GREY
BLUE
-
7021528872552
7021528873047
-
BFOV(C) 2PAIR 1.5mm²
GREY
-
7021528864496
-
20114112
886769
886449
Subject to change without prior notice
Page 168 of 212
New Part
number
20115151
20115152
20115155
Old Part
number
886451
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
BFOV(C) 4PAIR 1.5mm²
BFOV(C) 4PAIR 1.5mm²
BFOV(C) 8PAIR 1.5mm²
GREY
BLUE
GREY
-
7021528873061
7021528873078
7021528873085
-
BFOV(C) 8TRIP 1.5mm²
GREY
-
7021528864519
-
Other no. of pairs/triples and cross sectional area are available on request.
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius
Fixed Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 169 of 212
Hydraulic and Turbine oils resistant, power cable BFOV 0,6/1(1,2)kV
Fire resistant, flame retardant halogen-free power
cable. Resistant to turbine and hydraulic oils.
BFOV 0,6/1(1,2)kV
MGT/EPR/EPR/TCWB/HNBR
Operating temperature
Operating Voltage
: 90°C
: 0,6/1(1,2)kV
Standards applied
Application
Fixed installation for power, control and lighting in both
EX- and safe areas, emergency and critical systems
where requirement for fire resistance exists.
Especially resistant to the following hydraulic oils:
HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco
Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32.
IEC 60092-353
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-1, -2, -21
IEC 60754-1,2
IEC 61034-1,2
- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
B
F
Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned annealed copper wire braid
PET tape
V
Flame retardant, halogen-free and oil resistant thermoset compound (Therban),
SHF2 (IEC 60092-360)
E.g. meter" "year" DRAKA NORSK KABEL BFOV 0.6/1kV 3 x 4/6mm² FLEX FLAME IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22
Black
Marking text
Outer sheath
colour
*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm
**) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes
Subject to change without prior notice
Page 170 of 212
Core identification power cables
Single core
Black
Two cores
Blue - Brown
Three cores
Brown - Black - Grey
Four cores
Blue - Brown - Black - Grey
Five cores
Blue - Brown - Black - Grey - Black
Seven cores and above
White with black numbers
Two cores + earth (3G)
Yellow/green - Blue - Brown
Three cores + earth (4G)
Yellow/green - Brown - Black - Grey
Four cores + earth (5G)
Yellow/green - Blue - Brown - Black - Grey
G / X in cable description
G = One of the cores are yellow/green - X = no yellow/green core
Range and dimensions
Cross Cross
Number
Conductor Insulation
section section
of
Diameter, Thickness,
core,
screen,
elements
mm
mm
mm²
mm²
Thickness
Inner
covering,
mm
Diameter
Thickness
Diameter
inner
Outer
Braid
covering,
Sheath,
Wire, mm
mm
mm
Diameter
outer
sheath,
mm
Weight
of Cable
Approx.
(Kg/Km)
Copper
content
Approx.
(kg/km)
2
1.5
4
1.6
1.0
1.1
10 ± 0.8
0.3
1.2
285
79
2
2.5
6
2.0
1.0
1.1
11 ± 0.8
0.3
1.3
360
129
2
6
6
3.15
1.0
1.1
13 ± 0.8
0.3
1.4
13 ± 0.8
14.5 ±
0.8
17 ± 0.8
540
209
3
1.5
6
1.6
1.0
1.1
0.3
1.3
14.5 ±
0.8
350
125
3
2.5
6
2.0
1.0
1.1
0.3
1.3
15 ± 0.8
420
165
3
4
6
2.55
1.0
1.1
13 ± 0.8
0.3
1.3
500
209
3
6
6
3.15
1.0
1.1
0.3
1.4
620
280
3
16
16
5.15
1.0
1.1
14 ± 0.8
18.5 ±
0.8
16.5 ±
0.8
18 ± 0.8
0.4
1.5
23 ± 1
1170
660
10.5 ±
0.8
11.5 ±
0.8
Ordering information
New Part
number
Old Part
number
20117367
Description
Sheath Colour
Stock item
EAN No. DNK
EL No.
886453
886705
BFOV 0.6/1kV 2X 1.5/4mm²
BFOV 0.6/1kV 2X 2.5/6mm²
BFOV 0.6/1kV 2X 6/6mm²
BLACK
BLACK
BLACK
-
7021528873122
7021528864533
7021528867053
-
886666
886668
886744
BFOV 0.6/1kV 3X 1.5/6mm²
BFOV 0.6/1kV 3X 2.5/6mm²
BFOV 0.6/1kV 3X 4/6mm²
BFOV 0.6/1kV 3X 6/6mm²
BFOV 0.6/1kV 3X 16/16mm²
BLACK
BLACK
BLACK
BLACK
BLACK
-
7021528866674
7021528873115
7021528866667
7021528866681
7021528867442
-
20117363
20117365
Other no. of cores and cross sectional area are available on request.
Electrical values power cables
Number
of
elements
Cross
section
core,
mm²
Cross
section
screen,
mm²
Conductor
type 2
Max.
Max.
conductor
conductor
resistance at resistance at
20°C,
90°C,
Ohm/km
Ohm/km
Reactance
at 50Hz,
Ohm/km
Reactance
at 60Hz,
Ohm/km
Current
rating IEC
60092-352
Table B.4,
Ampere
Short
circuit
rating 1
second,
Ampere
2
2
2
1.6
2.5
6
4
6
6
STCC
STCC
STCC
12.2
7.56
3.11
15.6
9.64
3.97
0.115
0.107
0.094
0.138
0.129
0.112
16
26
44
210
350
840
3
3
3
1.5
2.5
4
6
6
6
STCC
STCC
STCC
12.2
7.56
4.7
15.6
9.64
5.99
0.115
0.107
0.100
0.138
0.129
0.120
16
21
28
210
350
560
Subject to change without prior notice
Page 171 of 212
Number
of
elements
3
3
Cross
section
core,
mm²
6
16
Cross Conductor
Max.
Max.
Reactance Reactance
Current
Short
section
type 2
conductor
conductor
at 50Hz,
at 60Hz,
rating IEC
circuit
screen,
resistance at resistance at
Ohm/km
Ohm/km
60092-352 rating 1
mm²
20°C,
90°C,
Table B.4,
second,
Ohm/km
Ohm/km
Ampere
Ampere
6
STCC
3.11
3.97
0.094
0.112
36
840
16
STCC
1.16
1.48
0.107
0.129
67
2240
Ambient temperature correction factors
Ambient Temp °C
Rating factor
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
Installation recommendations
Minimum Bending Radius during
Installation
8xD
Subject to change without prior notice
Minimum Bending Radius
Fixed Installed
6xD
Maximum Tensile Load During
Installation
50 N /mm²
Minimum Installation
Temperature
-20°C
Page 172 of 212
Hydro Carbon Fire Resistant Cables
Draka Norsk Kabel, part of the Prysmian Group, is a global solution supplier in cables, combining innovation
with technological leadership. Draka Norsk Kabel has developed a unique product range for use in critical
areas.
-
a complete range of Hydro Carbon Fire (HCF) resistant cables
The design is based on a fire proof elastomeric cable covered with our unique protective composite. Due to its
cooling and thermal properties this construction is capable of withstanding hydro carbon fires at 1100°C
(2000°F).
Excellence centre
Research and development is a continuous process at Prysmian Group and Draka Norsk Kabel, the
excellence centre in the overall group of specially designed products for Offshore applications, such as the
“Hydro Carbon Fire (HCF) resistant cables”. Draka Norsk Kabel has developed considerable expertise in
the area of fire resistant cables. Introduced in 1975, the first elastomeric cables were marketed under the name
BFOH. In the early eighties, they were replaced by the halogen-free BFOU, part of the Flex-Flame range.
Flexible and cost saving installation
The “FLEX-FLAME HCF” cable is flexible, easy to install and terminate whereas; similar products, e.g. cables
protected with extra thermal insulation, have the disadvantage of a higher derating factor as well as higher
installation costs. Mineral insulated cables have the disadvantage of alloy conductors, requiring larger conductor
cross-sectional areas, complex, time consuming installation and a limited range.
Subject to change without prior notice
Page 173 of 212
Properties of the design
The unique design of the cable gives good heat transmission during normal operating temperature, thus
reducing the requirement for derating. If the cable is exposed to a hydrocarbon fire, rapid changes in the
material state will give a cooling effect, which is maintained during the critical period.
When this process is completed, the layer will turn into a firm, ceramic substance which provides heat
insulation. Consequently, this is why the conductor temperature can be kept at a low level (approx.
500°C/900°F) even if the temperature should exceed 1100°C (2000°F). For Instrument and Communications
applications, the values of Capacitance, Inductance, Resistance and Attenuation are not unduly affected.
Certifications and approvals
According to most current requirements, the cables shall pass the IEC 60331 part 21 gas flame test at 750°C
(1350°F) for minimum 90 minutes without short circuit. This test temperature however, is more typical to
cellulose fires, not to hydrocarbon fires, the latter being more common in Refineries, Petrochemical Industry and
Production/Drilling Rigs.
The HCF cables will function in hydrocarbon fires exceeding 1100°C / 2000°F for a period of 30-60 minutes, in
accordance with EN 1363-2 / ISO 834. See fig. below.
Considering this important fact may be more crucial than enduring 90 minutes at lower temperatures (750 –
1000°C / 1350 – 1850°F). The outstanding performance of the HCF cable from Draka Norsk Kabel satisfies both
requirements.
Subject to change without prior notice
Page 174 of 212
The product portfolio range
The “FLEX-FLAME HCF” 1100°C (2000°F) cables cover the entire range from Instrument and
Telecommunications cables to Medium Voltage and High Voltage Power cables as described below.
Application:
Cable type/voltage:
Fire class:
Instrument and Telecommunication
Control
Power L.V.
Power M.V.
BFOU HCF 250 V
BFOU HCF 0,6/1 kV
BFOU HCF 0,6/1 kV
RFOU HCF 6/10 (12) kV
RFOU HCF 8,7/15 (17.5) kV
RFOU HCF 12/20 (24) kV
RFOU HCF 18/30 (36) kV
RFOU HCF 26/45 (52) kV
QFCI HCF
H-30
H-30
H-30 – H-60
H-60
H-60
H-60
H-60
H-60
H-30
Power H.V.
Optical fibre cable
Our state-of-the-art cable systems support many major customers in the oil, gas and petrochemical industry.
Now years of research and development within Draka Norsk Kabel has resulted in a range of cables, specially
designed for the Hydrocarbon Processing Industry’s most critical systems: Fire and Gas Detection, Emergency
Shutdown, Communications Systems etc.
Subject to change without prior notice
Page 175 of 212
Hydro Carbon Fire resistant instrument cable BFOU-HCF(i) 150/250(300)V, S15
HydroCarbon Fire resistant, flame retardant
halogen-free instrumentation cable.
BFOU-HCF(i)
150/250(300)V
1
5 4
2 3
MGT/EPR/EPR/TCWB/EVA/HCF/SHF1
NEK 606 Code S15
1100°C / 2000°F / 200 kW/m²
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation, communication,
control and alarm systems in both EX- and safe areas,
emergency and critical systems where requirement for
hydrocarbon fire resistance is vital.
IEC 60092-376 (2003-05)
Draka Norsk Kabel
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1
IEC 60332-3-22
IEC 60331-21
EN 1363-2 / ISO 834
IEC 600754-1,2
IEC 61034-1,2
- Design
- HCF protection
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- HC Fire resistance
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Inner covering
Tape over
bedding
Armour/screen
Tape over
armour/screen
Outer sheath
HCF protection
Tape
Overall sheath
Marking text
Outer sheath
colour
F
Tinned stranded circular copper, IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
Extruded heatblock compound
Lapped glassfibre tape
Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-360)
Eg. "meter" "år" DRAKA NORSK KABEL BFOU-HCF(i) 250V S15 4 PAIR 1,5 mm2
HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22
Grey, Blue or Black
-HCF
Subject to change without prior notice
Page 176 of 212
Core identification instrumentation cables
Black - Light Blue
Pair
Black - Light Blue - Brown
Triple
Range and dimensions
New Part
Old Part
number
number
Type
[mm2]
20118210
886723 Grey
1 pair 0,75
887086 Blue
1 pair 0,75
886722 Blue
Diameter Thickness of Diameter Diameter
over bedding
armour
sheath overall HCF[mm]
wires
protection
[mmØ]
[mm]
(mm)
7.5 ± 0.5
0.2
7.5 ± 0.5
0.2
1 triple 0,75
8,0 ± 0,5
0,2
886563 Grey
886714 Blue
886751 Black
Grey
886802 Grey
Grey
886803 Grey
886804 Grey
886805 Grey
1 pair 1,5
1 pair 1,5
1 pair 1,5
2 pair 1,5
4 pair 1,5
5 pair 1,5
8 pair 1,5
10 pair 1,5
12 pair 1,5
9,0±0,5
9,0±0,5
9,0±0,5
13,0±0,8
15,5±0,8
17.0±0,8
21.0±1,0
24,0±1.0
25,0±1,0
886710 Grey
Grey
1 triple 1,5
12 triple 1.5
Grey
1 pair 2.5
10.5 ±
0.8
10.5 ±
0.8
Weight
of cable
approx.
[kg/km]
37.0 ± 1,5
1500
37.0 ± 1,5
1500
11,0 ±
0,8
37,5 ± 1,5
1640
0,2
0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3
12,0±0,8
12,0±0,8
12,0±0,8
17,0±0,8
19,5±0,8
21,0±1,0
25,5±1,0
29,0±1,0
30.0±1,5
38,5±1,5
38,5±1,5
38,5±1,5
44,0±2,0
47,0±2,0
48,5±2,0
53.0±2,5
57,0±2,5
63,0±3.0
1880
1880
1880
2360
2730
2950
3570
9,5 ± 0,5
28.5 ± 1
0,2
0.3
12,5±0.8
33.5 ±
1.5
39,5±1,5
66.5 ± 3.0
1870
5770
9.5 ± 0.5
0.2
13.0 ±
0.8
39.5 ± 1.5
1900
5060
Other no. of cores and cross sectional area are available on request.
Electrical values instrumentation cables
Capacitance, approx.
Type
(nF/km)
Shielded pair 0,75 mm²
110
Shielded triple 0,75 mm²
110
Shielded pair 1,5 mm²
125
Shielded triple 1,5 mm²
125
Shielded pair 2,5 mm²
145
Shielded triple 2,5 mm²
145
Subject to change without prior notice
Inductance, approx,
(mH/km)
0,67
0,67
0,63
0,63
0,59
0,59
Resistance at 20°C, max.
(Ohm/km)
26,3
26,3
12,9
12,9
8,02
8,02
L/R ratio,
(microH/Ohm)
12,7
12,7
24,4
24,4
36,8
36,8
Page 177 of 212
Installation recommendations
TYPE
Overall
Diameter
[mmØ]
[mm2]
Minimum bending radius
During
Fixed
Installation
Installed
[mm]
20 x D
12 x D
Maximum
pulling tension
[N]
1 pair 0,75
1 triple 0,75
37.0 ± 1,5
37,5 ± 1,5
740
750
444
450
75
112,5
1 pair 1,5
2 pair 1,5
4 pair 1,5
5 pair 1,5
8 pair 1,5
10 pair 1,5
12 pair 1,5
38,5±1,5
44.0±2,0
47,0±2,0
48,5±2,0
53.0±2,5
57,0±2,5
63,0±3.0
770
880
940
970
1060
1140
1260
462
528
564
582
636
684
756
150
300
600
750
1200
1500
1800
1 triple 1,5
12 triple 1.5
39.5 ± 1.5
66.5 ± 3.0
790
1330
474
798
225
2700
1 pair 2.5
39.5 ± 1.5
790
474
250
Minimum installation temperature: - 10 °C
Subject to change without prior notice
Page 178 of 212
Hydro Carbon Fire resistant instrument cable BFOU-HCF(c) 150/250(300)V, S16
HydroCarbon Fire resistant, flame retardant
halogen-free instrumentation cable.
BFOU-HCF(c)
150/250(300)V
1
5 4
2 3
MGT/EPR/EPR/TCWB/EVA/HCF/SHF1
NEK 606 Code S16
1100°C / 2000°F / 200 kW/m²
Operating temperature
Operating Voltage
: 90°C
: 150/250(300)V
Standards applied
Application
Fixed installation for instrumentation, communication,
control and alarm systems in both EX- and safe areas,
emergency and critical systems where requirement for
hydrocarbon fire resistance is vital.
IEC 60092-376 (2003-05)
Draka Norsk Kabel
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-21
EN 1363-2 / ISO 834
IEC 60754-1,2
IEC 61034-1,2
- Design
- HCF protection
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- HC Fire resistance
- Halogen Free
- Low Smoke
Construction
Code
Letter
Conductor
Insulation
B
Pair / Triple /
Quad twisting
Inner covering
Tape over
bedding
Armour/screen
Tape over
armour/screen
Outer sheath
HCF protection
Tape
Overall sheath
F
Tinned stranded circular copper, IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
Flame retardant and halogen-free thermoplastic compound
PET tape
O
Tinned copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-360)
Extruded heatblock compound
Lapped glassfibre tape
Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-360)
Eg. "meter" "år" DRAKA NORSK KABEL BFOU-HCF(c) 250V S16 4 PAIR 1,5
mm2 HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22
Grey, Blue or Black
-HCF
Marking text
Outer sheath
colour
Subject to change without prior notice
Page 179 of 212
Core identification instrumentation cables
Black - Light Blue
Pair
Black - Light Blue - Brown
Triple
Range and dimensions
New Part
Old Part
number
number
Type
[mm2]
Diameter Thickness of Diameter Diameter
over bedding
armour
sheath overall HCF[mm]
wires
protection
[mmØ]
[mm]
(mm)
Weight
of cable
approx.
[kg/km]
886681 Black
8 pair 0,75
16.5±0.8
0.3
20.5± 1
40.5 ± 3
2790
886761 Blue
886562 Grey
886752 Black
886709 Grey
886762 Black
2 pair 1,5
4 pair 1,5
8 pair 1,5
12 pair 1,5
24 pair 1,5
13,0±0,8
15,0±0,8
20,0±1,0
24,0±1,0
33,5±1,5
0,3
0,3
0,3
0,3
0,4
16,5±0,8
19,0±0,8
24,5±1,0
28,5±1,0
39,5±1,5
44,0±2,0
46,0±2,0
52,5±2,5
56,5±2,5
72,5±3,5
2310
2600
3410
4030
6930
Other no. of cores and cross sectional area are available on request.
Electrical values instrumentation cables
TYPE
Capacitance Inductance
approx.
approx.
[mm2]
[nF/km]
[mH/km]
Unshielded pair 0.75mm²
Unshielded pair 1,5
Installation recommendations
TYPE
Overall
Diameter
[mmØ]
[mm2]
100
110
Resist. 20°C
L/R ratio,
(microH/Ohm)
[Max.ohm/km]
0.67
0,63
26.3
12,9
Minimum bending radius
During
Fixed
Installation
Installed
[mm]
20 x D
12 x D
12.7
24,4
Maximum
pulling tension
[N]
8 pair 0.75
40.5±2.0
810
486
600
2 pair 1,5
4 pair 1,5
8 pair 1,5
12 pair 1,5
24 pair 1,5
44,5±2,0
46,0±2,0
52,5±2,5
56,0±2,5
72,5±3,5
890
920
1050
1120
1450
534
552
630
672
870
300
600
1200
1800
3600
Minimum installation temperature: - 10°C
Subject to change without prior notice
Page 180 of 212
Hydro Carbon Fire resistant power cable BFOU-HCF 0,6/1(1,2)kV, P34
HydroCarbon Fire resistant, flame retardant
halogen-free power cable.
BFOU-HCF
0,6/1(1,2)kV
MGT/EPR/EPR/TCWB/EVA/HCF/SHF1
NEK 606 Code P34
1100°C / 2000°F / 200 kW/m²
Operating temperature
Operating Voltage
: 90°C
: 0,6/1kV
Standards applied
Application
Fixed installation for power, control and lightning in both
EX- and safe areas, emergency and critical systems where
requirement for fire resistance is vital.
IEC 60092-353
Draka Norsk Kabel
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-21
EN 1363-2 / ISO 834
IEC 600754-1,2
IEC 61034-1,2
- Design
- HCF protection
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- HC Fire resistance
- Halogen Free
- Low Smoke
Construction
Code Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over bedding
Armour/screen
Tape over
armour/screen
Outer sheath
HCF protection
Tape
B
F
O
U
-HCF
Overall sheath
Marking text
Outer sheath
colour
Subject to change without prior notice
Tinned stranded circular copper, IEC 60228 class 2
Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoplastic compound
PET tape
Tinned copper wire braid
PET tape
Flame retardant, halogen-free and mud resistant thermoset compound,
SHF2 (IEC 60092-360)
Extruded heatblock compound
Lapped glassfibre tape
Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092360)
Eg. "meter" "år" DRAKA NORSK KABEL BFOU-HCF 0,6/1kV P34 12 x
2,5/10 mm2 HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22
Black
Page 181 of 212
Core identification power cables
Single core
Black
Blue – Brown
Two cores
Blue - Brown - Yellow/green
Two cores + earth
Brown - Black – Grey
Three cores
Brown - Black - Grey - Yellow/green
Three cores + earth
Blue - Brown - Black – Grey
Four cores
Blue - Brown - Black - Grey - Yellow/green
Four cores + earth
Blue - Brown - Black - Grey - Black
Five cores
Above five cores
Black numbers on white base
Range and dimensions
New Part
Old Part
number
number
Type
[mm2]
886549
886375
886700
886338
885499
885882
885138
Diameter Thickness of Diameter Diameter
over bedding
armour
sheath overall HCF[mm]
wires
protection
[mmØ]
[mm]
(mm)
1x 50/6
1x 70/6
1x 95/10
1x 120/10
1x 150/10
1x 185/10
1x 240/16
1x 300/16
15,0±0,8
16,5±0,8
18,5±0,8
20,5±1,0
23,0±1,0
25,0±1,0
28,0±1,0
30,5±1,5
0,20
0,30
0,30
0,30
0,30
0,30
0,30
0,30
18,5±0,8
20,5±1,0
23,0±1,0
25,0±1,0
27,0±1,0
29,5±1,0
32,5±1,5
35,5±1,5
45,5±2,5
47,5±2,5
50,5±3,0
52,5±3,0
54,5±3,0
57,5±3,0
66,0±3,5
68,0±3,5
2900
3300
3800
4260
4750
5380
7050
8000
2x 1,5/4
2x 2,5/6
10,0±0,8
11,0±0,8
0,20
0,30
13,0±0,8
14,5±0,8
40,5±2,5
42,0±2,5
1890
2080
3x 1,5/4
3x 2,5/6
3x 4/6
3x 6/6
3x 16/16
3x 35/16
3x 70/35
3x 120/60
3x 150/70
10,5±0,8
11,5±0,8
13,0±0,8
14,0±0,8
18,5±0,8
25,0±1,0
33,0±1,5
41,0±2,0
46,0±2,0
0,20
0,30
0,30
0,30
0,40
0,30
0,50
0,60
0,40 *
14,0±0,8
15,0±0,8
16,5±0,8
18,0±0,8
23,0±1,0
29,5±1,0
39,0±1,5
48,0±2,0
54,5±2,5
42.0±2,5
42,5±2,5
43,0±2,5
45,0±2,5
50,0±3,0
57,5±3,0
72,0±4,0
81,5±4,5
88,5±4,5
2140
2200
2400
2600
3500
4840
8150
11300
13300
14.0 ± 0.8
0.30
18.0 ±
0.8
19.5 ±
0.8
22.0 ±
1.0
25.0 ±
1.0
45.5 ± 2.5
2580
47.5 ± 2.5
2870
50.0 ± 3.0
3180
53,5±3,0
3750
16.5 ±
0.8
18.0 ±
0.8
19.5 ±
0.8
22.0 ±
1.0
44,0±2,5
2300
45,5 ± 2,5
2650
47,5±2,5
2870
50.0 ± 3.0
3180
886799
3x 4 + E
886174
3x 6 + E
15.5 ± 0.8
0.30
886680
3x 10 + E
18.0 ± 0.8
0.30
886175
3x 16 + E
20.5 ± 1.0
0.30
886547
4x 2,5/6
12.5 ± 0.8
0.30
14.0 ± 0.8
0.30
15.5 ± 0.8
0.30
18.0 ± 0.8
0.30
4x 4/6
886607
4x 6/6
4x 10/10
Subject to change without prior notice
Weight
of cable
approx.
[kg/km]
Page 182 of 212
New Part
number
Old Part
number
Type
[mm2]
Diameter Thickness of Diameter Diameter
over bedding
armour
sheath overall HCF[mm]
wires
protection
[mmØ]
[mm]
(mm)
25.5 ±
53,0 ± 3,0
20.5 ± 1.0
0.40
1.0
25.0 ± 1.0
0.30
29.5 ±
58.5 ± 3.0
1.0
Weight
of cable
approx.
[kg/km]
886546
4x 16/16
3830
886644
4x 25/16
886676
4x 10 + E
20.0 ± 1.0
0.3
24.0 ±
1.0
52.5 ± 3.0
3540
886608
885139
7x 1,5/6
12x 1,5/10
14,0±0,8
18,5±0,8
0,30
0,30
17,5±0,8
22,5±1,0
44,5±2,5
50,0±3,0
2550
3140
885124
886036
7x 2,5/6
12x 2,5/10
15,0±0,8
20,5±1,0
0,30
0,30
19,0±0,8
24,5±1,0
46,0±2,5
52,0±3,0
2760
3500
886548
886645
27x 1,5/16
37x 1,5/16
26.5±1.0
30.0 ±1.5
0.30
0.30
31.0±1.5
35.5 ±
1.5
64,5±3,5
69.0 ± 3.5
5070
5920
4730
* This cable has a double braid (two layers of wires)
Other no. of cores and cross sectional area are available on request.
ELECTRICAL DATA
No. of cores Conductor resistance
x cross
DC
section
[/km]
at 20 °C
at 90 °C
Reactance
[/km]
at 50 / 60
Hz
Impedance
[/km] at 90
°C
At 50 / 60 Hz
Continous
current
rating
at 45 °C
Short circuit
[Ampere]
1 sec
0,3 sec
1 X 50/6
1 X 70/6
1 X 95/10
1 X 120/10
1 X 150/10
1 X 185/10
1 X 240/16
1 X 300/16
0,391
0,270
0,195
0,154
0,126
0,100
0,0762
0,0607
0,4986
0,344
0,2486
0,1964
0,161
0,128
0,0972
0,0774
0,161/0,193
0,152/0,182
0,146/0,176
0,141/0,170
0,137/0,164
0,133/0,160
0,133/0,159
0,128/0,154
0,524/0,535
0,376/0,390
0,289/0,305
0,242/0,260
0,211/0,223
0,185/0,205
0,165/0,187
0,150/0,173
196
242
293
339
389
444
522
601
7000
9800
13300
16800
21000
25900
3360
42000
12780
17892
24282
30672
38340
47286
61344
76681
2x 1,5/4
2x 2,5/6
12,2
7,56
15,56
9,64
0,115/0,138
0,107/0,129
15,556/15,567
9,640/9,641
20
26
210
350
383
639
3x 1,5/4
3x 2,5/6
3x 4/6
3x 6/6
3x 16/16
3x 35/16
3x 70/35
3x 120/60
3x 150/70
12,2
7,56
4,70
3,11
1,16
0,529
0,270
0,154
0,126
15,56
9,64
5,99
3,97
1,46
0,675
0,344
0,196
0,161
0,115/0,138
0,107/0,129
0,100/0,120
0,094/0,112
0082/0,099
0,078/0,094
0,077/0,092
0,073/0,088
0,073/0,088
15,556/15,567
9,640/9,641
5,993/5,994
3,967/3,9672
1,481/1,482
0,679/0,681
0,352/0,356
0,209/0,215
0,177/0,183
16
21
28
36
67
110
169
237
272
210
350
560
840
2240
4900
9800
16800
21000
383
639
1022
1534
4089
8946
17892
30672
38340
3x 4 + E
3x 6 + E
3x 10 + E
3x 16 + E
4,70
3,11
1.84
1,16
5,99
3,97
2.35
1,46
0,100/0,120
0,094/0,112
0.088/0.105
0082/0,099
5,993/5,994
3,967/3,9672
2.351/2.352
1,481/1,482
28
36
50
67
560
840
1400
2240
1022
1534
2556
4089
Subject to change without prior notice
Page 183 of 212
No. of cores
x cross
section
Conductor resistance
DC
[/km]
at 20 °C
at 90 °C
Reactance
[/km]
at 50 / 60
Hz
Impedance
[/km] at 90
°C
At 50 / 60 Hz
Continous
current
rating
at 45 °C
Short circuit
[Ampere]
1 sec
0,3 sec
4x 2,5/6
4x 4/6
4x 6/6
4x 10/10
4x 16/16
4x 25/16
7,56
4,70
3,11
1.84
1,16
0.734
9,64
5,99
3,97
2.35
1,46
0.936
0,107/0,129
0.100/0.120
0,094/0,112
0.088/0.105
0082/0,099
0.081/
9,640/9,641
5,991/5,9912
3,967/3,9672
2.351/2.352
1,481/1,482
0.098
21
28
36
50
67
89
350
560
840
1400
2240
3500
639
1022
1534
2556
4089
6390
4x 10 + E
1.84
2.35
0.088/0.105
2.351/2.352
50
1400
2556
7x 1,5/6
12x 1,5/10
12,2
12,2
15,56
15,56
0,115/0,138
0,115/0,138
15,556/15,567
15,556/15,567
12
10
210
210
383
383
7x 2,5/6
12x 2,5/10
7,56
7,56
9,64
9,64
0,107/0,129
0,107/0,129
9,640/9,641
9,640/9,641
15,5
13
350
350
639
639
27x 1,5/16
37x 1,5/16
12,2
12,2
15,56
15,56
0,115/0,138
0,115/0,138
15,556/15,567
15,556/15,567
7,5
7
210
210
383
383
INSTALLATION DATA
TYPE
Overall
Diameter
[mmØ]
[mm2]
Minimum bending radius
During
Fixed
Installation
Installed
[mm]
20 x D
12 x D
Maximum
pulling tension
[N]
1x 50/6
1x 70/6
1x 95/10
1x 120/10
1x 150/10
1x 185/10
1x 240/16
1x 300/16
45,5±2,5
47,5±2,5
50,5±3,0
52,5±3,0
54,5±3,0
57,5±3,0
66,0±3,5
68,0±3,5
910
950
1010
1050
1090
1150
1320
1360
546
570
606
630
654
690
792
816
2500
3500
4750
6000
7500
9250
12000
15000
2x 1,5/4
2x 2,5/6
40,5±2,5
42,0±2,5
810
840
486
504
150
250
3x 1,5/4
3x 2,5/6
3x 4/6
3x 6/6
3x 16/16
3x 35/16
3x 70/35
3x 120/60
3x 150/70
42,0±2,5
42,5±2,5
43,0±2,5
45,0±2,5
50,0±3,0
57,5±3,0
72,0±4,0
81,5±4,5
88,5±4,5
840
850
860
900
1000
1150
1440
1630
1770
504
510
516
540
600
690
864
978
1062
225
375
600
900
2400
5250
10500
18000
20000
3x 4 + E
3x 6 + E
3x 10 + E
3x 16 + E
45.5 ± 2.5
47.5 ± 2.5
50.0 ± 3.0
53,5±3,0
910
950
1000
1070
546
570
600
642
800
1200
2000
3200
Subject to change without prior notice
Page 184 of 212
TYPE
[mm2]
Overall
Diameter
[mmØ]
Minimum bending radius
During
Fixed
Installation
Installed
[mm]
880
528
910
546
950
570
1000
600
1060
636
1170
702
Maximum
pulling tension
[N]
4x 2,5/6
4x 4/6
4x 6/6
4x 10/10
4x 16/16
4x 25/16
44,0±2,5
45,5 ± 2,5
47,5±2,5
50.0 ± 3.0
53,0 ± 3,0
58.5 ± 3.0
4x 10 + E
52.5 ± 3.0
1050
630
2500
7x 1,5/6
12 x 1,5/10
44,5±2,5
50,0±3,0
890
1000
536
600
525
900
7x 2,5/6
12x 2,5/10
46,0±2,5
52,0±3,0
920
1040
552
624
875
1500
27x 1,5/16
37x 1.5/16
64,5±3,5
69.0 ± 3.5
1290
1380
774
828
2025
2775
500
800
1200
2000
3200
5000
Minimum installation temperature: - 10 °C
Subject to change without prior notice
Page 185 of 212
Hydro Carbon Fire resistant MV power cable RFOU-HCF 6/10(12)kV, P30
HydroCarbon Fire resistant, flame retardant
halogen-free medium voltage power cable.
RFOU-HCF
6/10(12)kV
EPR/EPR/TCWB/EVA/HCF/SHF1
NEK 606 Code P30
1100°C / 2000°F / 200 kW/m²
Operating temperature
Operating Voltage
: 90°C
: 6/10(12)kV
Standards applied
Application
Fixed installation for medium voltage (MV) power in both
EX- and safe areas, emergency and critical systems where
requirement for fire resistance is vital.
IEC 60092-354
Draka Norsk Kabel
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-21 and -31
EN 1363-2 / ISO 834
IEC 600754-1,2
IEC 61034-1,2
- Design
- HCF protection
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- HC Fire resistance
- Halogen Free
- Low Smoke
Construction
Code Letter
Conductor
Conductor screen
semiconductive
Insulation
Insulation screen
semicoductive
Tinned stranded and compressed copper (STCC), IEC 60228 class 2
Semiconductive layer (EP-rubber)
R
Lay up / Shielding
Inner covering
Tape over
bedding
Armour/screen
Tape over
armour/screen
Outer sheath
HCF protection
Tape
F
EP-rubber, IEC 60092-360 (EPR)
Semiconductive layer (EP-rubber)
Cores are laid up together. Cores are identified by Brown, Black or Grey
threads under and over the metallic screen on each conductor.
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound,
SHF2 (IEC 60092-360)
Extruded heatblock compound
Lapped glassfibre tape
Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092360)
Eg. "meter" "year" DRAKA NORSK KABEL RFOU-HCF 6/10(12)kV P30 1x
70/16 mm2 HCF 1100/60 FLEX - FLAME
Red
-HCF
Overall sheath
Marking text
Outer sheath
colour
Subject to change without prior notice
Page 186 of 212
Range and dimensions
New Part
Old Part
number
number
Type
Diameter Thickness of Diameter Diameter
over bedding
armour
sheath overall HCF[mm]
wires
protection
[mmØ]
[mm]
(mm)
[mm2]
886498
886795
887247
887182
Weight
of cable
approx.
[kg/km]
1x 70/16
1x 95/16
1x 120/20
1x 150/19
1x 185/18
1x 240/21
1x 300/29
23,5±1,5
25,5±1,5
27,5±1,5
28,5±1,5
30,5±1,5
33,0±1,5
35,0±1,5
0,3
0,3
0,3
0,3
0,3
0,3
0,3
30,0±2,0
32,0±2,0
34,0±2,0
35,0±2,0
36,5±2,0
39,0±2,0
41,5±2,5
62,0±3,0
64,5±3,0
66,5±3,0
67,5±3,0
69,0±3,0
72,0±3,5
74,5±3,5
5220
5900
6340
6670
7320
8250
9280
3x 50/31
47,0±2,0
0,4
55,0±3,0
89,0±4,5
10970
Other no. of cores and cross sectional area are available on request.
Type
Diameter of
copper
conductor
approx. mmØ
Insulation
thickness,
nominal
mm
Semiconducting
layer
thickness
approx. mm
Diameter over
insulated, screened
conductor,
approx. mm
1x 70/16
1x 95/16
1x 120/20
1x 150/19
1x 185/18
1x 240/21
1x 300/29
10,3
12,1
13,6
15,1
16,8
19,1
21.5
3,4
3,4
3,4
3,4
3,4
3,4
3,4
0,8
0,8
0,8
0,8
0,8
0,8
0,8
21,5
23,0
24,5
26,0
28,0
30,0
32,5
3x 50/31
8,8
3,4
0,8
20,0
(mm²)
ELECTRICAL DATA
No. of cores Conductor resistance
x cross
DC
section
[/km]
[mm2]
at 20 °C
at 90 °C
Reactance
[/km]
at 50 Hz
Impedance
[/km] at 90
°C
at 50 Hz
Continous
current
rating
at 45 °C
Short circuit
(conductor)
[Ampere]
1 sec
0,3 sec
1x 70/16
1x 95/16
1x 120/20
1x 150/19
1x 185/18
1x 240/21
1x 300/29
0,270
0,195
0,154
0,126
0,100
0,0762
0,0607
0,344
0,249
0,196
0,161
0,128
0,0972
0,0774
0,172
0,164
0,159
0,153
0,148
0,143
0,137
0,385
0,298
0,253
0,222
0,195
0,173
0,158
242
293
339
389
444
522
601
9800
13300
16800
21000
25900
33600
42000
17892
24282
30672
38340
47286
61344
76681
3x 50/31
0,391
0,499
0,108
0,261
137
7000
12780
Subject to change without prior notice
Page 187 of 212
INSTALLATION DATA
TYPE
Overall
Diameter
[mmØ]
[mm2]
Minimum bending radius
During
Fixed
Installation
Installed
[mm]
20 x D
12 x D
Maximum
pulling tension
[N]
1 x70/16
1x 95/16
1x 120/20
1x 150/19
1x 185/18
1x 240/21
1x 300/29
62,0±3,0
64,5±3,0
66,5±3,0
67,5±3,0
69,0±3,0
72,0±3,5
74,5±3,5
1240
1290
1330
1350
1380
1440
1490
744
774
798
810
828
864
894
3500
4750
6000
7500
9250
12000
15000
3x 50/31
89,0±4,5
1780
1068
7500
Minimum installation temperature: - 10 °C
The RFOU-HCF MV cables are available on request in all voltage levels from 3,6/6(7,2)kV up to and including
26/45(52)kV. Please be aware that we have a limitation on the cable diameter which allows us to manufacture
mainly single core cables on these voltage levels.
Subject to change without prior notice
Page 188 of 212
Hydro Carbon Fire resistant MV power cable RFOU-HCF 8,7/15(17,5)kV, P31
HydroCarbon Fire resistant, flame retardant
halogen-free medium voltage power cable.
RFOU-HCF
8,7/15(17,5)kV
EPR/EPR/TCWB/EVA/HCF/SHF1
NEK 606 Code P31
1100°C / 2000°F / 200 kW/m²
Operating temperature
Operating Voltage
: 90°C
: 8,7/15(17,5)kV
Standards applied
Application
Fixed installation for medium voltage (MV) power in both
EX- and safe areas, emergency and critical systems where
requirement for fire resistance is vital.
IEC 60092-354
Draka Norsk Kabel
IEC 60228 class 2
IEC 60092-360
IEC 60092-360
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-21
EN 1363-2 / ISO 834
IEC 600754-1,2
IEC 61034-1,2
- Design
- HCF protection
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- HC Fire resistance
- Halogen Free
- Low Smoke
Construction
Code Letter
Conductor
Conductor screen
semiconductive
Insulation
Insulation screen
semicoductive
Tinned stranded and compressed copper (STCC), IEC 60228 class 2
Semiconductive layer (EP-rubber)
R
Lay up / Shielding
Inner covering
Tape over
bedding
Armour/screen
Tape over
armour/screen
Outer sheath
HCF protection
Tape
F
EP-rubber, IEC 60092-360 (EPR)
Semiconductive layer (EP-rubber)
Cores are laid up together. Cores are identified by Brown, Black or Grey
threads under and over the metallic screen on each conductor.
Flame retardant and halogen-free thermoset compound
PET tape
O
Tinned copper wire braid
PET tape
U
Flame retardant, halogen-free and mud resistant thermoset compound,
SHF2 (IEC 60092-360)
Extruded heatblock compound
Lapped glassfibre tape
Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092360)
Eg. "meter" "year" DRAKA NORSK KABEL RFOU-HCF 8,7/15(17,5)kV P31
3x 35/35 mm2 HCF 1100/60 FLEX - FLAME
Red
-HCF
Overall sheath
Marking text
Outer sheath
colour
Subject to change without prior notice
Page 189 of 212
Range and dimensions
New Part
Old Part
number
number
Type
Diameter
over bedding
[mm]
[mm2]
Thickness of
armour
wires
[mmØ]
Diameter
sheath
Diameter
overall HCFprotection
[mm]
Weight
of cable
approx.
[kg/km]
(mm)
Type
1x 70/20
1x 120/20
26.0 ± 1.5
29.5 ± 1.5
0.4
0.4
32.0 ± 1.5
36.0 ± 2.0
64.5 ± 3.0
69.0 ± 3.0
5750
6850
3x 35/35
49,0 ± 2,0
0,5
57,5 ± 3,0
92,0 ± 4,5
11600
Diameter of
copper
conductor
approx. mmØ
Insulation
thickness,
nominal
mm
Semiconducting
layer
thickness
approx. mm
Diameter over
insulated, screened
conductor,
approx. mm
1x 70/20
1x 120/20
10.3
13.6
4.5
4.5
0.8
0.8
21.8
26.0
3x 35/35
7.4
4.5
0.8
19.6
(mm²)
ELECTRICAL DATA
No. of
Conductor resistance
cores x
DC
cross
[/km]
section
[mm2]
at 20 °C
at 90 °C
Reactance
[/km]
Impedance
[/km] at 90
°C
Continous
current
rating
Short circuit
(conductor)
[Ampere]
at 50 Hz
at 50 Hz
at 45 °C
1 sec
0,3 sec
1x 70/20
1x 120/20
0.270
0.154
0.339
0.193
0.130
0.120
0.156
0.144
225
320
9800
16800
17892
30672
3x 35/35
0.529
0.675
0.122
0.685
100
4900
8946
INSTALLATION DATA
TYPE
Overall
Diameter
[mmØ]
[mm2]
Minimum bending radius
During
Fixed
Installation
Installed
[mm]
20 x D
12 x D
Maximum
pulling tension
[N]
1x 70/20
1x 120/20
64.5 ± 3.0
69.0 ± 3.0
1290
1380
774
828
3500
6000
3x 35/35
92,0±4,5
1840
1104
5250
Minimum installation temperature: - 10°C
The RFOU-HCF MV cables are available on request in all voltage levels from 3,6/6(7,2)kV up to and including
26/45(52)kV. Please be aware that we have a limitation on the cable diameter which allows us to manufacture
mainly single core cables on these voltage levels.
Subject to change without prior notice
Page 190 of 212
Approvals
Our cables carry these major approvals:
RFOU (c) 250V
RFOU (i) 250V
RFOU (c) 250V Arctic Grade
RFOU (i) 250V Arctic Grade
RU (c) 250V
RU (i) 250V
RFOU 0,6/1 kV
RFOU 0,6/1 kV Arctic Grade
RFOU 3,6/6(7,2)kV
RFOU 6/10(12) kV
RFOU 8,7/15(17,5) kV
RFOU 12/20(24) kV
RU 0,6/1 kV
UX 1000V
BFOU (c) 250V
BFOU (i) 250V
BFOU (c) 250V Arctic Grade
BFOU (i) 250V Arctic Grade
BFOU-XFR (c) 250V
BFOU-XFR (i) 250V
BFCU-XFR (c) 250V
BFCU-XFR (i) 250V
BU (c) 250V
BU (i) 250V
BFOU 0,6/1 kV
BFOU 0,6/1 kV Arctic Grade
BU 0,6/1kV
BFCU (c) 250V
BFCU (i) 250V
BFCU 0,6/1kV
RFCU (c) 250V
RFCU (i) 250V
RFCU 0,6/1kV
QFCI
AICI
ToughCat 5e S/FTP
ToughCat 7 S/FTP
ToughCat 7S S/FTP
DET
NORSKE
VERITAS
AMERICAN
BUREAU OF
SHIPPING
LLOYDS
REGISTER
OF
SHIPPING
BUREAU
VERITAS
RUSSIAN
MARITIME
REGISTER
OF
SHIPPING
























































All cables are designed in accordance with IEC 60092-350, IEC 60092-353, IEC 60092-354 and IEC 60092-376 except those marked
with *) . They are designed in accordance with BS 6883
Subject to change without prior notice
Page 191 of 212
Standards and tests
Standards
Designation Title
IEC 60092-350
Electrical installations in ships Part 350: General construction and test methods of power, control and instrumentation
cables for shipboard and offshore applications
IEC 60092-352
Electrical installations in ships Part 352: Choice and installation of electrical cables
IEC 60092-353
Electrical installations in ships –
Part 353: Single and multicore non-radial field power cables with extruded solid
insulation for rated voltage 1 kV and 3 kV.
IEC 60092-354
Electrical installations in ships –
Part 354: Single -and three-core power cables with extruded solid
insulation for rated voltages 6 kV (Um = 7,2kV) up to 30 kV (Um = 36 kV)
IEC 60092-360
Electrical installations in ships –
Part 359: Insulating and sheathing materials for shipboard and offshore units,
power, control, instrumentation and telecommunication cables
IEC 60092-376
Electrical installations in ships –
Part 376: Cables for control and instrumentation circuits 150/250 V (300 V)
IEC 60228
Conductors of insulated cables.
IEC 60331-1
Test method for fire with shock at a temperature of at least 830°C for cables of rated
voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm
IEC 60331-2
Test method for fire with shock at a temperature of at least 830°C for cables of rated
voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm
IEC 60331-3
Test method for fire with shock at a temperature of at least 830°C for cables of rated
voltage up to and including 0,6/1,0 kV tested in a metal enclosure
IEC 60331-11
Test for electric cables under fire conditions – Circuit integrity – Part 11
Apparatus – Fire alone at a flame temperature of at least 750°C
IEC 60331-21
Test for electric cables under fire conditions – Circuit integrity – Part 21
Procedures and requirements – Cables of rated voltage up to and including 0,6/1kV
IEC 60331-25
Test for electric cables under fire conditions – Circuit integrity – Part 25
Procedures and requirements – Optical fibre cables
IEC 60332-1-1
Test on electric and optical fibre cables under fire conditions. Part 1-1
Test for vertical flame propagation for a single insulated wire or cable - Apparatus
IEC 60332-1-2
Test on electric and optical fibre cables under fire conditions. Part 1-2
Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1
kW pre-mixed flame
IEC 60332-1-3
Test on electric and optical fibre cables under fire conditions. Part 1-3
Test for vertical flame propagation for a single insulated wire or cable – Procedure for
determination of flaming droplets/particles
IEC 60332-2-1
Test on electric and optical fibre cables under fire conditions. Part 2-1
Test for vertical flame propagation for a single small insulated wire or cable - Apparatus
IEC 60332-2-2
Test on electric and optical fibre cables under fire conditions. Part 2-2
Test for vertical flame propagation for a single small insulated wire or cable – Procedure
Subject to change without prior notice
Page 192 of 212
Standards
Designation Title
for diffusion flame
IEC 60332-3-10
Tests on electric and optical fibre cables under fire conditions.
Part 3-10: test for vertical flame spread of vertically-mounted bunched wires or cables –
Apparatus
IEC 60332-3-21
Tests on electric cables under fire conditions. Part 3-21
Test for vertical flame spread of vertically-mounted bunched wires or cables
– Category A F/R
IEC 60332-3-22
Tests on electric and optical fibre cables under fire conditions.
Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables
– Category A
IEC 60332-3-23
Tests on electric and optical fibre cables under fire conditions.
Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables
– Category B
IEC 60332-3-24
Tests on electric and optical fibre cables under fire conditions.
Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables
– Category C
IEC 60332-3-25
Tests on electric and optical fibre cables under fire conditions.
Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables
– Category D
IEC 60445
Basic and safety principles for man-machine interface, marking and
identification –
Identification of equipment terminals, conductor terminations and conductors
Test on gases evolved during combustion of electrical cables.
Part 1: Determination of the amount of halogen acid gas.
IEC 60754-1
IEC 60754-2
Test on gases evolved during combustion of electrical cables.
Part 2: Determination of degree of acidity of gases evolved during the combustion of
materials taken from electric cables by measuring pH and conductivity.
IEC 60811-100
Electric and optical fibre cables – Test methods for non-metallic materials –
Part 100: General
IEC 61034-1
Measurement of smoke density of cables burning under defined conditions.
Part 1: Test apparatus.
IEC 61034-2
Measurement of smoke density of cables burning under defined conditions.
Part 2: Test procedure and requirements.
IEC 61892-4
Mobile and fixed offshore units Electrical installations –
Part 4: Cables
Subject to change without prior notice
Page 193 of 212
Definition of terms
Flame retardance
The cables shall withstand the test specified in IEC 60332-3-22/-23/-24.
Single, earth and bonding wires shall withstand the test specified in IEC 60332-1-2.
Fire resistance
Fire resistant cables shall be tested in accordance with IEC 60331-1, 60331-2, 60331-21 and
IEC 60331-25 (optical fibre cables).
Content of halogen
To demonstrate that the cables are halogen-free they shall be tested to IEC 60754-1;
- maximum content of halogen = 5 mg/g.
Alternatively the cables shall be tested to IEC 60754-2;
- pH value should not be less than 4,3
- The conductivity value should not exceed 10 µS/mm.
Smoke Emission
During a cable fire the smoke emission is recommended to have a minimum value of 60% when tested
in accordance with IEC 61034-2
Oil resistance
For cables with thermoplastic sheath material there are no requirements
for oil resistance properties.
All thermoset sheathed cables shall be suitable for an oil production installation.
The oil resistance properties shall be demonstrated by a test according to
IEC 60092-360 SHF-2 with the cable immersed in IRM oil no. 902 at 100°C for 24 hours.
Mud resistance
In accordance with NEK TS 606 the mud resistant cables shall have a sheath that complies with
the requirements in IEC 60092-360 for SHF2 and the below specified.
Mud resistant cables shall be designed with sheathing compounds suitable for installation and operation
in contact with MUD unless otherwise specified.
The MUD resistance test requirements for sheathing compounds are as follows:
Test fluid
Temperature
Duration
Tensile
strength
variation
Elongation at
break
variation
Volume
swell
variation
Weight
increase
variation
Mineral oil type IRM
903
100°C
7d
30%
30%
30%
30%
Calcium Bromide
Brine (Waterbased)
70°C
56 d
25%
25%
20%
15%
EDC-95-11
(Oil based)
70°C
56 d
25%
25%
20%
15%
Subject to change without prior notice
Page 194 of 212
Fire, flame, smoke and corrosion test methods
Cables' integrity during a fire
Fire resistance
During a fire it is vital that emergency circuits should continue to function.
This could be communication circuits, emergency lights, alarms and fire pumps, etc.
On oil rigs and platforms and other confined areas this could be a matter of life and death.
Cables that will function in a fire ensuring circuit integrity
BFOU / BFCU / BU cables
These cable types have Mica tape applied around the conductors which are then insulated with heat-resistant
EPDM and have and outer sheathing of a halogen-free thermoset material. BFOU cables have metal braid
armour between the insulation and outer sheathing.
Test method
IEC 60331 -21 and -25, 750°C fire for 90 minutes.
As an option we offer cables to 1000°C for 3 hours with an upgraded IEC 60331-21 and -25 test.
IEC 60331-1 or 60331-2 fire test at 830°C for 90 minutes with hammer shock
Our range of BFOU-XFR with eXtended Fire Resistant properties can also withstand the
IEC 60331-1 or 60331-2 fire test at 830°C for 90 minutes with hammer shock (every 5 minutes) followed by 90
minutes fire with waterspray in accordance with EN 50200 ANNEX E + hammershock every 5 minutes
Flame propagation
Flame retardant cables must be self-extinguishing when the source of flames dies out.
Flame retardant cables with built-in self-extinguishing properties
These cables have sheathing and bedding with hydrated flame retardants that provide resistance to ignition and
flame spread.
Test methods
IEC 60332 – 1
IEC 60332 – 3 – 22/23/24 (category A, B and C, respectively)
IEC 60332 - 3
(Category)
Amount of combustible material in
litres per metre of cable ladder
Burning time
Minutes
- 22 (Cat. A)
- 23 (Cat. B)
- 24 (Cat. C)
7
3,5
1,5
40
40
20
Subject to change without prior notice
Page 195 of 212
Smoke risk to personnel
Smoke evolution is of major significance in situations where
escape routes are limited in the event of fire.
Cables having exceptionally low smoke emission
All offshore topside cables and fire resistant cables listed in this catalogue,
have sheathing and insulation based on halogen-free materials.
To minimize the risk of smoke and toxic gases, each component from
conductor tapes to outer sheath has been taken into consideration.
Test method
3 m Cube Test for the measurement of smoke density.
IEC 61034 - 2
Damage to expensive equipment
Corrosion
Halogen-free cables will not cause corrosion to metals.
When halogen - containing cables burn, the gases generated
in combustion of the sheathing and insulation may cause corrosion.
The secondary effects after a fire are often many times larger than
the damages caused by the fire itself.
Test method
IEC 60754 - 1
IEC 60754 - 2
Subject to change without prior notice
Page 196 of 212
Installation recommendations
The following installation recommendations are in accordance with IEC regulations and practice.
Different regulations may apply in other countries.
Minimum cable bending radius.
Cables for rated voltages up to 0,6/1 kV, in accordance with IEC 60092-352.
Outer diameter
of cable
D < 25mm
D > 25mm
Minimum bending radius
when fixed installed
Unbraided cables
Braided
cables
4D
6D
Minimum bending radius
during installation
6D
6D
8D
8D
Medium voltage cables up to and including 12/20(24) kV:
Minimum bending radius during installation:
Minimum bending radius when fixed installed:
15D
9D
Installation temperature.
Minimum recommended installation temperature for cables of rated voltage up to 30 kV, such as:
RFOU – BFOU – RU – BU
-20°C
RFOU – BFOU Arctic Grade
-40°C
Pulling tension.
The cable pulling tension during installation can be estimated by means of the following formula:
p=
50 N 
total cross section of conductors in the armoured cable
25 N 
total cross section of conductors in the unarmoured cable
or
p=
Additional tension will be supplied from the braid and the insulation and sheathing compound.
Subject to change without prior notice
Page 197 of 212
Electrical data
Conductor Resistance
Resistance formula:
L
R=p

A
R = resistance in ohm per phase
Ohm  mm2

p = specific resistance
m
A = conductor area mm², L = conductor length, m
Resistance as a function of temperature:
R = R0 (1 +  (t-20 C))
R = Resistance at t=20C, t = conductor temperature °C,  = 0,00393 for copper
Conductor resistance tinned annealed copper 250V.
In accordance with IEC 60092-376.
Nominal
No. of wires
conductor
and diameter
area
of wires
Approx.
diam.
mm²
mm
mmØ
0,5
0,75
1
1,5
2,5
7x 0,30
7x 0,36
7x 0,43
7x 0,525
7x 0,67
0,9
1,1
1,3
1,6
2,0
Max. resistance
pr km
20°C
ohm
41,6
26,3
19,3
12,9
8,02
90°C
ohm
53,0
33,5
24,6
16,4
10,2
Conductor resistance tinned annealed copper 0,6/1kV, 1,8/3(3,6)kV.
In accordance with IEC 60228, class 2. Tinned stranded annealed copper conductors for single core and multicore cables 0,6/1kV and 1,8/3kV
Nominal
conductor
area
No. of wires
and diameter
of wires
Approx.
diam.
mm²
mm
mmØ
1
1,5
2,5
4
6
10
16
25
35
50
70
95
7x 0,43
7x 0,525
7x 0,67
7x 0,85
7x 1,05
7x 1,35
7x 1,71
7 x 2,15
19x 1,53
19x 1,80
19x 2,17
37x 1,80
1,3
1,6
2,0
2,55
3,15
4,05
5,15
6,45
7,65
9,1
10,85
12,6
Subject to change without prior notice
Max. resistance
pr km
20°C
ohm
18,2
12,2
7,56
4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
90°C
ohm
23,2
15,6
9,64
5,99
3,97
2,35
1,48
0,936
0,675
0,499
0,344
0,249
Page 198 of 212
Nominal
conductor
area
No. of wires
and diameter
of wires
Approx.
diam.
mm²
120
150
185
240
300
400
500
630
mm
37x 2,03
37x 2,27
37x 2,52
61x 2,24
61x 2,52
91x 2,36
91x 2,64
127x 2,52
mmØ
14,2
15,9
17,7
20,15
22,6
26,0
29,0
32,8
Max. resistance
pr km
20°C
ohm
0,154
0,126
0,100
0,0762
0,0607
0,0475
0,0369
0,0286
90°C
ohm
0,196
0,161
0,128
0,0972
0,0774
0,0606
0,0463
0,0359
Conductor resistance, tinned annealed copper conductor
3,6/6(7,2)kV, 6/10(12)kV, 8,7/15(17,5)kV, 12/20(24)kV and 18/30(36)kV.
In accordance with IEC 60228, class 2. Compressed tinned stranded annealed copper conductors
for single core and multicore cables 3,6/6kV, 6/10kV, 8,7/15kV, 12/20(24)kV and 18/30(36)kV.
Nominal
conductor
area
No. of wires
and diameter
of wires *)
Approx.
diam.
mm²
mm
mmØ
16
25
35
50
70
95
120
150
185
240
300
7x 1,71
7 x 2,14
19x 1,53
19x 1,80
19x 2,17
37x 1,80
37x 2,03
37x 2,27
37x 2,52
61x 2,24
61x 2,52
5,2
6,5
7,4
8,8
10,3
12,1
13,6
15,1
16,8
19,1
21,5
Max. resistance
pr km
20°C
ohm
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100
0,0762
0,0607
90°C
ohm
1,48
0,936
0,675
0,499
0,344
0,249
0,196
0,161
0,128
0,0972
0,0774
*) Diameter of wires before compressing
Subject to change without prior notice
Page 199 of 212
Wire gauge conversion table
US Standard cross-section to square millimetres
U.S. Standard
Equivalent
cross-section
mm²
Nearest available
cross-section
mm²
20 AWG
18
16
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250 MCM
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1250
1500
1750
2000
0.519
0.823
1.31
2.08
3.31
5.26
8.37
13.30
21.15
33.62
42.41
53.49
67.23
85.01
107.2
126.7
152.0
177.3
202.7
228.0
253.4
278.7
304.0
329.4
354.7
380.0
405.4
430.7
456.0
481.4
506.7
633.4
760.0
886.7
1013.4
0.5 – 0.75
1.0
1.5
2.5
4
6
10
16
25
35
50
50 - 70
70
95
120
120 - 150
150
185
185
185-240
240
240 – 300
300
300
300 – 400
400
400
400
400
400
400 – 630
630
800
800 – 1000
1000
Subject to change without prior notice
Page 200 of 212
Current ratings for 250V and 0,6/1kV cables in fixed installations.
Current carrying capacities in continuous service at maximum rated temperature of 90°C.
In accordance with IEC 60092-352 (2005) Annex B, Table B.4. Ambient temperature 45°C
Conductor area
mm²
1-core
Amp
2-core
Amp
3-4 core
Amp
1
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
18
23
30
40
52
72
96
127
157
196
242
293
339
389
444
522
601
690 dc / 670 ac
780 dc / 720 ac
890 dc / 780 ac
15
20
26
34
44
61
82
108
133
167
206
249
288
331
377
444
511
587 dc / 570 ac
663 dc / 612 ac
757 dc / 663 ac
13
16
21
28
36
50
67
89
110
137
169
205
237
273
311
365
421
483 dc / 469 ac
546 dc / 504 ac
623 dc / 546 dc
For cables with more than 4 cores, the current ratings are given by the following formula:
I1
I= 
3
N
I1 = current rating for single core
N = number of cores
No. of
cores
1,5 mm²
Amp
2,5 mm²
Amp
5
7
12
19
24
37
13
12
10
9
8
7
18
16
13
11
10
9
Subject to change without prior notice
Page 201 of 212
Current rating for 1,8/3(3,6)kV, 3,6/6(7,2)kV, 6/10(12)kV, 8,7/15(17,5)kV,
12/20(24)kV and 18/30(36)kV cables in fixed installations.
Current carrying capacities in continuous service at maximum rated temperature of 90°C.
In accordance with IEC 60092-352 (2005) Annex B, Table B.4.
Conductor area
mm²
1-core
Amp
2-core
Amp
3-4 core
Amp
16
25
35
50
70
95
120
150
185
240
300
400
500
630
96
127
157
196
242
293
339
389
444
522
601
690 dc / 670 ac
780 dc / 720 ac
890 dc / 780 ac
82
108
133
167
206
249
288
331
377
444
511
-
67
89
110
137
169
205
237
273
311
365
421
-
The tabled current ratings must be adjusted for ambient air temperatures other than 45°C.
Appropriate rating factors are:
Ambient air temp. °C
Rating factors
35
40
45
50
55
60
65
70
75
80
1,10 1,05 1,00 0,94 0,88 0,82 0,74 0,67 0,58 0,47
Subject to change without prior notice
Page 202 of 212
Short circuit ratings
The following short circuit currents are for cables normally operating at a maximum conductor temperature of
90°C.
The theoretical temperature that arises in the conductor during a short circuit, which is used as a basis of the
calculation, is 250°C. EPR and XLPE insulation are capable of withstanding short term temperatures up to
250°C.The short circuit currents for copper conductors given in the table are values for one second, for other
durations the current may be calculated from the following formula:
I
It = 
t
It = short ciricut current for t sec. (Amp),
l = short circuit current for one sec. (Amp),
t = short circuit duration (sec.)
The duration of the short circuit based on these assumptions should be between 0,2 sec. and 5 sec.
Conductor area
mm²
Current
1 second amperes
Conductor
area
mm²
Current
1 second amperes
1,0
1,5
2,5
4
6
10
16
25
35
50
140
210
350
560
840
1400
2240
3500
4900
7000
70
95
120
150
185
240
300
400
500
630
9800
13300
16800
21000
25900
33600
42000
56000
70000
88200
Reactance
The reactance of a cable operating in an AC system depends on many factors, including, in particular, the axial
spacing between conductors and the proximity and magnetic properties of adjacent steelwork. The former is
known for multicore cable, but may vary for single core cables depending upon the spacing between them and
their disposition when installed. Reactance of cables in certain disposition when installed. Reactance of cables in
certain dispositions remote from steelwork are calculable and are shown. The tabulated values are for cables
with circular conductors. The value for a sector-shaped conductor should be taken as 90% of the calculated
value.
Induction for 2-, 3- and 4- conductor cables is given by the formula:
2a
-6
L = 0,2 * ( In (  ) + 0,25 ) * 10
d
L = Induction in H/m and phase, a = Axial space between conductors in mm.
d = conductor diameter in mm.
Reactance for 2-, 3- and 4-conductor cables is given by the formula:
X=2**f*L*I
X = Reactance in ohm pr. Phase, f = frequency in Hz, L = Induction in H/m and phase
I = Conductor length in meter.
Reactance Values for Cables
Power and control cables. RFOU 0,6/1 kV
Subject to change without prior notice
Page 203 of 212
Crosssection
2-, 3- and 4 cores
ohm/km
mm²
60 Hz
50 Hz
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
0,132
0,123
0,115
0,108
0,101
0,096
0,095
0,092
0,092
0,088
0,088
0,086
0,087
0,086
0,086
0,086
0,110
0,103
0,096
0,090
0,084
0,080
0,079
0,076
0,076
0,074
0,073
0,072
0,072
0,072
0,072
0,071
1- core*
ohm/km
60 Hz
0,140
0,132
0,128
0,125
0,119
0,116
0,113
0,111
0,109
0,107
0,105
50 Hz
0,116
0,110
0,106
0,104
0,099
0,097
0,094
0,092
0,091
0,089
0,087
*) Reactance for 1-conductor cables given at Three- foil formation
Power and control cables, BFOU 0,6/1 kV.
Cross- section
2-, 3- and 4 core
ohm/km
mm²
60 Hz 50 Hz
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
0,138
0,129
0,120
0,112
0,105
0,099
0,098
0,094
0,093
0,090
0,090
0,088
0,088
0,088
0,087
0,086
0,115
0,107
0,100
0,094
0,088
0,082
0,081
0,078
0,078
0,075
0,075
0,073
0,073
0,073
0,072
0,072
1- core* ohm/km
60 Hz
0,142
0,136
0,129
0,126
0,120
0,116
0,114
0,112
0,110
0,108
0,106
50 Hz
0,118
0,114
0,108
0,105
0,100
0,097
0,095
0,094
0,092
0,090
0,088
*) Reactance for 1-conductor cables given at Three- foil formation
Subject to change without prior notice
Page 204 of 212
Medium Voltage Power cables. RFOU 6/10 kV
Cross3 core
1- core*
section
ohm/km
ohm/km
mm²
50 Hz 60 Hz
50 Hz 60 Hz
16
25
35
50
70
95
120
150
185
240
300
400
500
630
0.119
0.119
0.114
0.108
0.103
0.098
0.095
0.092
0.092
0.087
0.084
-
0.154
0.144
0.138
0.132
0.125
0.119
0.116
0.111
0.108
0.104
0.104
0.090
0.097
0.092
0.143
0.143
0.137
0.130
0.124
0.118
0.114
0.111
0.111
0.104
0.101
-
0.185
0.173
0.166
0.158
0.150
0.142
0.139
0.133
0.130
0.125
0.124
0.118
0.117
0.110
*) Reactance for 1-conductor cables given at Three- foil formation
Medium Voltage Power cables. RFOU 12/20(24)kV.
Cross3 core
1-core*
section
ohm/km
ohm/km
mm²
50 Hz 60 Hz
50 Hz 60 Hz
35
50
70
95
120
150
185
240
300
0.128
0.121
0.115
0.109
0.105
0.102
0.099
0.095
-
0.149
0.140
0.133
0.127
0.124
0.119
0.116
0.112
0.108
0.153
0.145
0.135
0.131
0.126
0.122
0.118
0.114
-
0.178
0.169
0.160
0.152
0.149
0.142
0.139
0.134
0.130
*) Reactance for 1-conductor cables given at Three- foil formation
Impedance
Induction for 2-, 3- and 4- conductor cables is given by the formula:
Z=  (R +X )
2
2
Z = Impedansce in ohm pr. phase,
R = Resistance at operating temprature in ohm pr. phase.
X = Reactance in ohm pr. phase.
Subject to change without prior notice
Page 205 of 212
Electrical characteristics for instrumentation and telecommunication cables
such as 250 V cables: RFOU and BFOU according to IEC 60092-376
Cables with collective screen
Type
Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm)
Unshielded pair 0,75 mm²
Unshielded triple 0,75 mm²
100
100
0,67
0,67
26,3
26,3
12,7
12,7
Unshielded pair 1,5 mm²
Unshielded triple 1,5 mm²
110
110
0,63
0,63
12,9
12,9
24,4
24,4
Unshielded pair 2,5 mm²
Unshielded triple 2,5 mm²
125
125
0,59
0,59
8,02
8,02
36,8
36,8
Unshielded 16 and 24 pair 2,5 mm²
Unshielded 16 triple 2,5 mm²
95
95
0,66
0,66
8,02
8,02
41,1
41,1
Cables with individually screened pair/triples
Type
Shielded pair 0,75 mm²
Shielded triple 0,75 mm²
Shielded pair 1,5 mm²
Shielded triple 1,5 mm²
Shielded pair 2,5 mm²
Shielded triple 2,5 mm²
Shielded 16 and 24 triple 1,5 mm²
Shielded 16 pair 2,5 mm²
Subject to change without prior notice
Capacitance, approx.
(nF/km)
110
110
125
125
145
145
105
110
Inductance, approx,
(mH/km)
0,67
0,67
0,63
0,63
0,59
0,59
0,71
0,66
Resistance at 20°C, max.
(Ohm/km)
26,3
26,3
12,9
12,9
8,02
8,02
12,9
8,02
L/R ratio,
(microH/Ohm)
12,7
12,7
24,4
24,4
36,8
36,8
24,4
41,1
Page 206 of 212
Material properties
Polymeric materials used in cables for ships and offshore topside installations
For more than 30 years Draka Norsk Kabel has been facing the same challenge :
The increasing severe performance criteria demands from our ship and offshore customers.
Elastomers are the major part of our cable construction.
The insulation, bedding and sheathing have been developed through intensive
research and development to meet the offshore and ship industry's specific and stringent
requirements.
This information is not intended to give you details of the elastomers in use.
For correct selection and application of materials our technical representatives will be pleased to
provide you with more complete information.
EP - rubber (EPDM)
EPDM is a hydrocarbon rubber that combines electrical performance suitable for fire resistant
offshore cables with mechanical toughness and resistance to ozone, UV light and heat.
Its wet electrical properties are unique.
Applications : Wire insulation
Bedding compounds
Flame retardant halogen-free termoset compound (EVA)
EVA, ethylene vinyl acetate, is a multi-functional elastomer,
which resists the combined deteriorating influences of heat, oil and weather.
(In accordance with IEC 60092-360, type SHF2). For offshore applications, EVA can be
compounded to produce high quality cable sheathing with low smoke and flame propagation, and
with no emission of halogenous acids.
Applications : Cable sheathing on offshore oil platforms,
ships, hotels and in rooms with expensive
equipment, which must not be subjected to
corrosion damage.
Low smoke , Flame retardant , Halogen-free and Thermoplastic compounds , HFFR.
When PVC is not acceptable due to the problems chlorine (halogen) containing materials
present in the event of a fire HFFR must be used.
(In accordance with IEC 60092-360, type SHF1).
Our HFFR materials will not propagate a fire along a cable run, drip or give off black smoke.
No acid gases will be released during a fire that can corrode and damage expensive
equipment.
Applications:
Cable sheathing for
Rooms with IT equipment
High - rise buildings (hotels)
Hospitals
Telephone exchanges
Subway systems, airports and many others.
Subject to change without prior notice
Page 207 of 212
XLPE – Crosslinked Polyethylene
Polyethylene is the most used plastic material. By introducing chemical bonding between the chains in
PE we get XLPE, a thermoset type of PE.
In cable insulation it is used for the excellent insulation properties , very good mechanical
strength , low density and good thermal stability.
Applications :
Wire insulations
Physical and chemical properties of Draka's sheathing compounds for use in offshore
topside and shipboard cables
Enhanced
oil
resistant
EVA
(SHF2)
3-4
NITRILE/
PVC
PVC
HFFR
Arctic
Grade
Hydraulic
Oil
Resistant
4
4
(SHF1)
2-3
(SHF2)
3-4
(SHF2)
4
Weathering (O2 -O3 )
5
4
5
4-3
5
4-5
Heat resistance
4
3
2-3
4
4
4
Low temperature
3
3
2
3
5
3-4
3-4
4
2
0
3-4
3-4
3-4*
4
1
0
3-4*
3-4*
Hydraulic oils
Sea-water
1
3
1-2
4
1
4
0
3
2
3
5
3-4
Fire resistant
4
3
4
4
4
4
Oxygen Index
4
3
4
4
4
4
Smoke generation
5
2
1
5
4-5
4-5
No
CI
CI
No
No
No
Mechanical
properties
Hydrocarbons
general
Hydrocarbons high
aromatic (MUD)
Halogens
5 - Excellent, 4 - Very good, 3 - Good, 2 - Medium, 1 - Poor, 0 - Not recommended
* Drilling MUD is not one chemical, but a mix of different chemicals and each producer have their own
composition. The sheathing material could be resistant to the aromatics in the MUD, but be affected by other
chemicals like corrosion inhibitors. Each MUD must therefore be tested for compatibility with the cable
sheathing. The test method for this MUD test is described in NEK TS 606: 2009 Fourth edition.
Subject to change without prior notice
Page 208 of 212
SHF1 versus SHF2
The table below addresses only some main characteristics differences.
For complete information see IEC 60092-360
Type of material
SHF1
Halogen-free
Thermoplastic
SHF2
Halogen-free
Elastomeric or
thermosetting material
Some main characteristics
Mechanical characteristics after
immersion in hot oil
(IEC 60811-404)
No requirements
100 °C for 24 hours:

±40% maximum
variation in tensile
strength:

±40% maximum
variation in
elongation at
break
Hot set test
(IEC 60811-507)
No requirements
200 °C, 15 min time
under load with 20
(N/mm²) mechanical
stress:

175% Maximum
elongation under
load

25% Maximum
permanent
elongation after
cooling
Pressure test at high temperature
IEC 60811-508)
80 °C, 4-6 h under load
depending on cable
diameter:

50% Maximum
permissible
deformation
No requirements
Heat shock test
(IEC 60811-509)
150 °C) 1h duration:
No requirements
Ozone resistance test
IEC 60811-403
(Alternative test method B may be
used)
Subject to change without prior notice
No requirements
25 ± 2°C for 24 h:

275±25)
-4
x 10
ozone
concentration (in
volume)
Page 209 of 212
Core colours for cables according to NEK TS 606
Please look at the actual page for each cable type.
Instrumentation and communications cable for fixed installation (conductor size from 0,75 mm² and
above) such as RFOU, BFOU, RU and BU 250V.
Pair:
Black -- Light blue
Triple: Black -- Light blue - Brown
Pairs and triples are identified by numbered tape with printed black numbers.
Power and control cables for fixed installation, such as RFOU, BFOU, RU and BU 0,6/1kV
One core:
Two cores:
Two cores + earth
Three cores:
Three cores + earth
Four cores:
Four cores + earth
Five cores
Above 5-cores :
Black
Blue – Brown
Blue – Brown – Yellow/green
Brown - Black – Grey
Brown - Black – Grey – Yellow/green
Blue - Brown - Black– Grey
Blue - Brown - Black– Grey – Yellow/green
Blue - Brown - Black– Grey - Black
Black numbers on white base.
Colours are in accordance with IEC 60445 and Cenelec HD 308S2
Medium Voltage cables for fixed installation, RFOU
1-core : Off-white insulation + black semi-conductive layer.
3-cores : Off-white insulation + black semi-conductive layer identified by Brown - Black - Grey threads under
and over the metallic screen on each individual core.
Separate earth conductor (if any): Yellow/green
Subject to change without prior notice
Page 210 of 212
Drum capacity in meters
Free
space
mm.
Drum
No:
30
30
30
30
30
30
30
40
50
60
60
60
60
70
70
80
90
100
Free
space mm
R5
R6
R6T
R8
R9
R10
R10A
R11
R12
R14
R14A
R16
R16A
R18
R20
R22
R24
R26
Drum
No:
Overall
cable
diam.mm
Overall
cable
diam.mm
10
360
720
850
1470
12
250
500
565
1020
1440
14
185
370
425
770
1105
1520
16
280
10
12
550
825
1160
18
450
620
920
20
375
14
1335
570
16
1010
1510
18
510
745
460
850
1100
1565
1065
22
420
615
380
700
885
1925
880
1645
20
24
340
515
320
580
830
1075
740
1380
870
26
440
270
470
685
905
630
1175
740
1485
28
380
235
440
555
745
540
985
635
1255
30
330
22
24
26
1685
28
205
345
525
705
470
930
555
1045
1375
32
180
330
410
560
415
755
490
980
1300
1565
30
32
34
160
395
545
370
735
430
825
1105
1350
34
36
140
370
420
330
580
385
765
1035
1265
38
130
285
405
295
560
345
630
860
1070
1570
40
115
36
38
390
265
445
310
605
830
1035
1355
2060
40
42
300
240
430
285
485
640
820
1255
1870
42
44
285
220
410
260
460
620
790
1065
1700
44
46
200
390
235
440
595
760
1025
1560
46
48
185
315
215
445
595
635
895
1430
48
50
170
300
200
340
460
605
855
1320
50
52
160
285
185
320
440
580
820
1220
52
54
145
285
170
320
420
550
665
1130
54
56
135
160
300
420
445
670
1050
56
58
125
150
300
420
425
635
980
58
60
120
140
215
400
425
640
915
60
62
130
215
310
400
500
860
62
64
120
290
405
500
805
64
66
115
290
380
475
755
66
68
110
275
295
475
715
68
70
100
275
275
445
675
70
72
255
275
360
635
72
74
260
275
360
600
74
76
255
335
570
76
78
255
335
540
78
Subject to change without prior notice
Page 211 of 212
Code designation for cables
A cable code of 2 - 4 letters is used to descriebe the construction.
Additional abbrevation for instrumentation cables: Collective screen = (c) Individual pair or triple screen = (i)
The interpretation ( per letter) can be read from the table below:
1st. letter:
Insulation
2nd. letter
Bedding / inner sheath
3rd. letter
Armouring / screen
4th. letter
Outer sheath
A
Fibre, tight cladded
A
Aluminium (optional with
corrosion protection)
A
Strength member yarn
A
Yarn + bitumen
B
Fire resistant tape +
insulation (Halogen-free)
B
Corrogated aluminium
(o.w.c.p.)
B
Steel tapes, 2 off
B
Hydrocarbon resistant
sehath
C
Polychloroprene
(Neoprene) PCP, or
chlorinated polyethylene CPE
C
Polychloroprene
(Neoprene) PCP, or
chlorinated polyethylene CPE
C
Galvanized steel wire braid
C
Polychloroprene
(Neoprene) PCP, or
chlorinated polyethylene CPE
D
Impregnated paper
Drip free
D
Aluminium + Plastics
D
Oil filled cable
reinforcement
(Longitudinal / Transverse)
D
E
Polyethylene - PE
Polypropylene - PP
E
Polyethylene - PE
Polypropylene - PP
E
Oil filled cable
reinforcement
(Transverse only)
E
Polyethylene - PE
Polypropylene - PP
F
PE or PP +
filling compound
F
Bedding or taping
(Halogen-free)
F
Flat steel wire armour
F
Semi-conducting PE
G
Polyamid - PA
G
G
PE + PA
H
Chlorosulphonated
polyethylene - CSP
H
Chlorosulphonated
polyethylene - CSP
H
Steel tape +
steel wires
H
Chlorosulphonated
polyethylene - CSP
I
Thermoplastic compound
(Halogen-free)
I
Thermoplastic compound
(Halogen-free)
I
Steel tapes, 4 off
I
Thermoplastic compound
(Halogen-free)
K
Paper
K
Lead
K
Steel wire, plastics or
rubber coated
K
Lead
L
Air + plastics
(Coaxial cable)
L
Aluminium laminate +
plastics sheath
L
Aluminium (laminated to
outer jacket)
L
M
Expanded PE or PP
+ filling compound
M
Polyester
M
N
Impregnated paper
N
Polyurethane
N
O
Impregnated paper,
oilfilled cable
O
Lead + Plastics
P
Polyvinylchloride - PVC
P
Polyvinylchloride - PVC
Q
Fibre in loose tube
Q
R
Ethylenepropylene rubber EPR
R
S
Silicone rubber
T
G
M
Polyester
Steel (laminated to
outer jacket)
N
Polyurethane
O
Copper wire braid
(Tinned or bare)
O
P
Phosphorbronze
wire braid
P
Q
Steel wires + counter
steel tape (optional)
Q
Ethylenepropylene rubber EPR
R
Steel wires (round)
+ filling compound
R
Ethylenepropylene
rubber - EPR
S
Bedding or taping +
concentric conductor
S
Concentric conductor
(Screen)
S
Silicone rubber
Cross-linked polyethylene
XLPE
T
PE + aluminium wire +
steel tape
T
T
Cross-linked
polyethylene XLPE
U
Halogen-free thermoset
compound EMA or EVA
U
Halogen-free thermoset
compound EMA or EVA
U
U
Halogen-free thermoset
compound EMA or EVA
V
Fibre, slotted core
V
Aluminium screen
V
Double wire armour
(two layers)
V
Other halogen-free
thermoset materials
W
Other materials
W
Other materials
W
Catenary wire
W
Other materials
X
No insulation
X
No bedding or equivalent
X
No armour
X
No sheath
Y
Screen
Y
Y
Z
Flour plastics
Z
Z
Y
Z
Flour plastics PTFE / FEP
Subject to change without prior notice
Polyvinylchloride - PVC
Flour plastics
Page 212 of 212
Draka Norsk Kabel AS
VISITING ADDRESS
Kjerraten 16
3013 DRAMMEN
NORWAY
Tel:
Fax:
+47 32 24 90 00
+47 32 24 91 45
www.prysmiangroup.no
POSTAL ADDRESS
Postboks 369 Bragernes
3001 DRAMMEN
NORWAY