guidewires for neuro interventional procedures
Transcription
guidewires for neuro interventional procedures
Ordering Information ■ Structure ● ASAHI CHIKAI 200 cm Radiopaque length:5cm 0.36mm(0.014”) Stainless steel core Precise, safe and durable guidewires for neuro interventional procedures SLIP-COAT® Coating Length 170cm Usable Length 200cm ● ASAHI CHIKAI 300 cm Radiopaque length:5cm 0.36mm(0.014”) PTFE coating Stainless steel core SLIP-COAT® Coating Length 170cm Usable Length 300cm ● ASAHI CHIKAI 10 200cm Radiopaque length:3cm 0.26mm(0.010”) steel core 0.014” a n d Stainless 0.010” Neurovascular Guide Wires 0.014” and 0.010” Neu rova sc u l a r Gu ide W i re s Dual-coil Design Hydrophilic Coating SLIP-COAT® Coating Length 170cm ASAHI INTECC CO., LTD.’s unique Usable Length 200cm technologies in wire drawing, wire forming, torque transmission and coating are utilized to ● ASAHI CHIKAI 10 300cm PTFE coating 0.26mm(0.010”) highly responsive Stainlessguide steel core wires featuring ASAHI’s ACTONE, Radiopaque lengthcreate :3cm dual-coil design. Spring coil Stainless steel core ACTONE SLIP-COAT® Coating Length 170cm Usable Length 300cm Key Features Product Catalog No. Diameter Usable Length Spring Coil Length Radiopaque Length Tip Shape 5 cm Straight ■ Precise torque response 0.36 mm ASAHI CHIKAI cm WAIN-CKI-200 – ACTONE provides exceptional response200 in tortuous anatomy.30 cm (0.014torque inch) 0.36 mm 300 and microcatheter 30 navigation through anatomy delivery5 ■ EasyWAIN-CKI-300 (0.014 distal ) inch cm cm – ASAHI CHIKAI and ASAHI CHIKAI 0.26 mm 10 are designed with optimum balance between tip WAIN-CKI-10-200 ASAHI CHIKAI 10 (0.010 inch) flexibility and microcatheter support. WAIN-CKI-10-300 0.26 mm (0.010 inch) ■ Durable tip-shape retention cm Straight 200 cm 9.5 cm 3 cm Straight 300 cm 9.5 cm 3 cm Straight – ACTONE dual-coil is designed to maintain tip shape for vessel selectivity ASAHI ACTONE technology and catheter positioning. Not all shapes and sizes are available in all markets. Please check availability with your sales representative. Coated with SLIP-COAT coating. SLIP-COAT is a trademark of Angiotech BioCoatings Corp. in the U.S. and /or other countries. ASAHI and CHIKAI are trademarks or registered trademarks of ASAHI INTECC CO., LTD. in Japan and other countries. ACTONE is a hollow wire rope that incorporates three of ASAHI INTECC's core technologies - wire drawing, wire forming, and torque transmission. http://www.asahi-intecc.com ASAHI CHIKAI series/ver.1 Stainless steel core Precise, safe and durable guidewires for neuro interventional procedures Dual-coil Design 0.014” a n d 0.010” N e u r o v a s c u l a r G u i d e W i r e s Hydrophilic Coating ASAHI INTECC CO., LTD.’s unique technologies in wire drawing, wire forming, torque transmission and coating are utilized to create highly responsive guide wires featuring ASAHI’s ACTONE, dual-coil design. Spring coil Stainless steel core ACTONE Key Features ■ Precise torque response – ACTONE provides exceptional torque response in tortuous anatomy. ■ Easy navigation through distal anatomy and microcatheter delivery – ASAHI CHIKAI and ASAHI CHIKAI 10 are designed with optimum balance between tip flexibility and microcatheter support. ■ Durable tip-shape retention – ACTONE dual-coil is designed to maintain tip shape for vessel selectivity and catheter positioning. ASAHI ACTONE technology ACTONE is a hollow wire rope that incorporates three of ASAHI INTECC's core technologies - wire drawing, wire forming, and torque transmission. Stainless steel core