Thermal In Situ Technologies - case study CVOC in LNAPL

Transcription

Thermal In Situ Technologies - case study CVOC in LNAPL
SARCLE 2013, AMSTERDAM OCT 21-24
CLIQUEZ ET MODIFIEZ LE TITRE
- TPS TECH thermal in situ technologies
- Case: Treatment of CVOC in LNAPL
1
CLIQUEZ ET MODIFIEZ LE TITRE
TPS TECHNOLOGIES SA
Agenda
TPS TECH – Who are we?
Gas Thermal Remediation (GTR)
Case: FORD Motors
2
CLIQUEZ ET MODIFIEZ LE TITRE
TPS TECHNOLOGIES SA
Agenda
TPS TECH – Who are we?
Gas Thermal Remediation (GTR)
Case: FORD Motors
3
TPS TECH - In Situ Thermal Desorption
+ Technology provider
-
20 -plus years experience
- > 8 millions tons treated by thermal desorption
• Conventional: rotating kiln technology
• Mobile
- Own technology development - Innovation!
- GTR (Gas Thermal Remediation)
- C-3
- Worldwide patents
+ Many international partners
- Remediation contractors using TPS technologies
www.tpstech.com
TPS TECH = TPS + GEO (since 2013)
TPS TECH
GEO inc
Thermal Desorption
Off-gas treatment
- Own patents: GTR
- Own patents: C3
- In-Situ
- In-Situ
Liquid  Gas
Gas  Liquid
Integral Solution to fully eliminate the pollution on location,
restoring land value at fixed costs...
5
CLIQUEZ ET MODIFIEZ LE TITRE
TPS TECHNOLOGIES SA
Agenda
TPS TECH – Who are we?
Gas Thermal Remediation (GTR)
Case: FORD Motors
6
GTR - Gas Thermal Remediation (in-situ)
7
ISTD: principles - GTR
+ Phase 1: Heat the soil
- With in-situ heating elements (horizontal, vertical, oblique)
- By conduction
+ Phase 2: Treat contaminated gas
- C-3 technology (Compress – Cool – Condensate)
- Thermal oxidation (hydrocarbons)
• Reuse pollutants as fuel (hydrocarbons)
Maximum reuse of heat produced
8
Phase 1: Heating the soil
burner
circulating
2 coaxial steel pipes
“Cold” air out (400° C)
Hot air in (700° C)
Heating the soil through conduction,
 contaminants vaporise
9
Phase 2: Gas treatment: recycling
C-3 unit
Fresh air
Fuel
GTR©
-
Compressing
Cooling
Condensing
Vapor extraction pipe
Polluted gases
OR: thermal oxidation
Supplementary fuel for the burner
C-3 unit
Fresh air
Fuel
GTR©
Vapor extraction pipe
Polluted gases
GTRTM (Gas Thermal Treatment)
•
•
•
•
•
•
Simple
Effective
Flexible
Easy to handle
Scalable
Affordable
Evolution: GTRTM
•
•
•
•
No excavation
Flexible
Easy to handle
No nuisance for neighbours
(patent 2010)
Modularity - flexibility
NSR1
NSR1
NSR1
NSR1
NSR1
NSR1
Only heat what you need to treat
www.tpstech.com
Design
Cold point:
Center of triangle
Tube
Radius of
influence of the
tube
How do we know it is clean?
Target temperature of the soil achieved (during sufficient
time)
Indirect measurements (TPS):
CO extracted vapor
Direct measurements (soil
sampling by consultant)
16
Treatable pollutants
+ Boiling point (patm)
+ Kinetic equation
17
Evolution soil temperature
www.tpstech.com
BOFAS
Optimising energy use
Design with 1 burner per 2 tubes
19
Phases in off-gas treatment
1. Separate water – chemicals (contaminants)
2. Compress the vapor
3. Cool the vapor
4. Condense the chemicals (contaminants)
5. Option: filter the final off-gas (adsorption)
22
C3 Technology is a combination of compression, cooling, and condensation coupled
with proprietary regenerative adsorption
C-3 : >1,300,000 Gallons Recovered
Chlorinated Ethenes
PCE (Perchloroethene)
TCE (Trichloroethene)
Petroleum Hydrocarbons
DCE (Dichloroethene)
Fuels (gasoline, diesel, jet)
VC
Simple Aromatics (BTEX)
(Vinyl Chloride)
Chlorinated Ethanes
4-ethyltoluene
TCA (Trichloroethane)
Napthylene
DCM (Methelene Chloride)
CT
(Carbon Tetrachloride)
CF
(Chloroform)
CFCs (Freon 113)
GTR installed
25
Vertical wells
27
CLIQUEZ ET MODIFIEZ LE TITRE
TPS TECHNOLOGIES SA
Agenda
TPS TECH – Who are we?
Gas Thermal Remediation (GTR)
Case: FORD Motors
28
Location (Bordeaux)
Degreasing
operation
29
The site
+ 300 m2 contaminated, 4,5 m bgs
+ Sand, LNAPL of engine oil (2 m)
+ Contaminants: CVOC’s (PCE, TCE, DCE,...) in
LNAPL
+ Max concentration in oil: 145 mg/kg
+ Target: mass reduction of CVOC’s in oil: 99 %
+ Target soil temperature: 100º C
30
Initial concentrations of CVOC’s in oil
31
Liquid mixtures – Eutectic points & azeotropes
Compound
Boiling point (°C)
Co-distillation point
(°C)
(Eutectic point)
Tetrachloroéthene
121
88.5
1,1,2-Trichloroethane
113.7
86
Trichloroethene
87.1
73.1
32
Lab test: time effect on CVOC’s at 80ºC
33
Lab test: temperature effect after 24 h
34
Lab test showed:
•
A minimal temperature has to be reached to ensure the
distillation of CVOCs out of oils.
•
Undetectable low levels are reached rapidly (less than 24
hours à 100°C).
•
During the in situ application, interactions may occur with the
soil matrix, shifting the optimal temperature a few degrees
higher.
35
Conceptual model
Pump & Treat
LNAPL
Hydraulic barrier
Treat
Pump
Reinject
36
Set-up Pilot test
+ Cover a representative
zone
+ Depth down to
groundwater
+ Target on codistillation CVOC
- 6 heating tubes
- 3 burners
- 7 vapour extraction
tubes
Ford Motors: Pilot with 3 burners tubes
Vapour treatment
Soil
Vapor treatment
Monitoring/Safety
Monitoring/Safety
Temperature
measurement
30 thermocouples
placed in soil and gas
lines:
Gas analysis
During all the period of treatment, the gases to be analyzed in the vapour and the exhaust stack
are:
HCl, (PCE), Oxygen (O2); Carbon monoxide (CO); Carbon dioxide (CO2); Nitrogen oxides (NOx);
The sulphur dioxide (SO2) and hydrocarbons HCT.
Alarms/Safety
•burner temperature (operation: stopping burner when temperature of gas after flame exceed the
limit temperature (e.g. 1100°C) and sends sms)
•Inlet fan temperature (operation: opening fresh air valve and sends sms)
•Electricity off (operation: send sms)
Soil temperature dvt
43
Pilot: mass reduction of CVOC’s
44
Results
+ Target temperature reached after 20 days heating
+ CVOC’s reduction: > 50 %
+ No harmful gases emitted
+ GTR proven as a safe technology
45
– Pilot results – Pumping assays
Pumping 3tests
oil productivity
X7
X2
18 °C
28 °C
0,1 m3/h
0,74 m3/h
45 °C
1,5 m3/h
Optimization of pumping performances !
Full scale Installation
+ 280m² to treat 4,5 m
depth
+ 63 boreholes
+ 42 heating wells
+ 19 hexagonal grids –
2.2m interdistance
+ 19 SVE wells
+ 5 weeks project duration
47
Installation (2)
+ Natural gas and electrical connection
+ Insulation
48
Combustion gas and electrical network
49
FORD Motors: distillation TCE from LNAPL
Monitoring
51
Surveillance program
+ Ambiant air – daily
- VOC
- Explosivity
- O2
- CO
- H2S
+ Ambiant air – sampling
campaigns for VOC’s
52
Results air (emissions)
Ambiant air
Exhaust air
53
Results - Temperatures
54
Results – COVC’s in Oil LNAPL
PZ-TD1
PZ-TD2
PZ-TD3
PZ-TD4
55
CLIQUEZ ET MODIFIEZ LE TITRE
CONTENT
The case
Proposed solution
Lab study
Pilot
Full scale
Conclusions
56
Conclusions and perspectives
+ ISTD proven as fractionned distillation technology
+ Initial characterization essential for accurate timing
estimate and planning
+ Cost efficient
TPS TECH International Licenses
58
www.tpstech.com
59