Thermal In Situ Technologies - case study CVOC in LNAPL
Transcription
Thermal In Situ Technologies - case study CVOC in LNAPL
SARCLE 2013, AMSTERDAM OCT 21-24 CLIQUEZ ET MODIFIEZ LE TITRE - TPS TECH thermal in situ technologies - Case: Treatment of CVOC in LNAPL 1 CLIQUEZ ET MODIFIEZ LE TITRE TPS TECHNOLOGIES SA Agenda TPS TECH – Who are we? Gas Thermal Remediation (GTR) Case: FORD Motors 2 CLIQUEZ ET MODIFIEZ LE TITRE TPS TECHNOLOGIES SA Agenda TPS TECH – Who are we? Gas Thermal Remediation (GTR) Case: FORD Motors 3 TPS TECH - In Situ Thermal Desorption + Technology provider - 20 -plus years experience - > 8 millions tons treated by thermal desorption • Conventional: rotating kiln technology • Mobile - Own technology development - Innovation! - GTR (Gas Thermal Remediation) - C-3 - Worldwide patents + Many international partners - Remediation contractors using TPS technologies www.tpstech.com TPS TECH = TPS + GEO (since 2013) TPS TECH GEO inc Thermal Desorption Off-gas treatment - Own patents: GTR - Own patents: C3 - In-Situ - In-Situ Liquid Gas Gas Liquid Integral Solution to fully eliminate the pollution on location, restoring land value at fixed costs... 5 CLIQUEZ ET MODIFIEZ LE TITRE TPS TECHNOLOGIES SA Agenda TPS TECH – Who are we? Gas Thermal Remediation (GTR) Case: FORD Motors 6 GTR - Gas Thermal Remediation (in-situ) 7 ISTD: principles - GTR + Phase 1: Heat the soil - With in-situ heating elements (horizontal, vertical, oblique) - By conduction + Phase 2: Treat contaminated gas - C-3 technology (Compress – Cool – Condensate) - Thermal oxidation (hydrocarbons) • Reuse pollutants as fuel (hydrocarbons) Maximum reuse of heat produced 8 Phase 1: Heating the soil burner circulating 2 coaxial steel pipes “Cold” air out (400° C) Hot air in (700° C) Heating the soil through conduction, contaminants vaporise 9 Phase 2: Gas treatment: recycling C-3 unit Fresh air Fuel GTR© - Compressing Cooling Condensing Vapor extraction pipe Polluted gases OR: thermal oxidation Supplementary fuel for the burner C-3 unit Fresh air Fuel GTR© Vapor extraction pipe Polluted gases GTRTM (Gas Thermal Treatment) • • • • • • Simple Effective Flexible Easy to handle Scalable Affordable Evolution: GTRTM • • • • No excavation Flexible Easy to handle No nuisance for neighbours (patent 2010) Modularity - flexibility NSR1 NSR1 NSR1 NSR1 NSR1 NSR1 Only heat what you need to treat www.tpstech.com Design Cold point: Center of triangle Tube Radius of influence of the tube How do we know it is clean? Target temperature of the soil achieved (during sufficient time) Indirect measurements (TPS): CO extracted vapor Direct measurements (soil sampling by consultant) 16 Treatable pollutants + Boiling point (patm) + Kinetic equation 17 Evolution soil temperature www.tpstech.com BOFAS Optimising energy use Design with 1 burner per 2 tubes 19 Phases in off-gas treatment 1. Separate water – chemicals (contaminants) 2. Compress the vapor 3. Cool the vapor 4. Condense the chemicals (contaminants) 5. Option: filter the final off-gas (adsorption) 22 C3 Technology is a combination of compression, cooling, and condensation coupled with proprietary regenerative adsorption C-3 : >1,300,000 Gallons Recovered Chlorinated Ethenes PCE (Perchloroethene) TCE (Trichloroethene) Petroleum Hydrocarbons DCE (Dichloroethene) Fuels (gasoline, diesel, jet) VC Simple Aromatics (BTEX) (Vinyl Chloride) Chlorinated Ethanes 4-ethyltoluene TCA (Trichloroethane) Napthylene DCM (Methelene Chloride) CT (Carbon Tetrachloride) CF (Chloroform) CFCs (Freon 113) GTR installed 25 Vertical wells 27 CLIQUEZ ET MODIFIEZ LE TITRE TPS TECHNOLOGIES SA Agenda TPS TECH – Who are we? Gas Thermal Remediation (GTR) Case: FORD Motors 28 Location (Bordeaux) Degreasing operation 29 The site + 300 m2 contaminated, 4,5 m bgs + Sand, LNAPL of engine oil (2 m) + Contaminants: CVOC’s (PCE, TCE, DCE,...) in LNAPL + Max concentration in oil: 145 mg/kg + Target: mass reduction of CVOC’s in oil: 99 % + Target soil temperature: 100º C 30 Initial concentrations of CVOC’s in oil 31 Liquid mixtures – Eutectic points & azeotropes Compound Boiling point (°C) Co-distillation point (°C) (Eutectic point) Tetrachloroéthene 121 88.5 1,1,2-Trichloroethane 113.7 86 Trichloroethene 87.1 73.1 32 Lab test: time effect on CVOC’s at 80ºC 33 Lab test: temperature effect after 24 h 34 Lab test showed: • A minimal temperature has to be reached to ensure the distillation of CVOCs out of oils. • Undetectable low levels are reached rapidly (less than 24 hours à 100°C). • During the in situ application, interactions may occur with the soil matrix, shifting the optimal temperature a few degrees higher. 35 Conceptual model Pump & Treat LNAPL Hydraulic barrier Treat Pump Reinject 36 Set-up Pilot test + Cover a representative zone + Depth down to groundwater + Target on codistillation CVOC - 6 heating tubes - 3 burners - 7 vapour extraction tubes Ford Motors: Pilot with 3 burners tubes Vapour treatment Soil Vapor treatment Monitoring/Safety Monitoring/Safety Temperature measurement 30 thermocouples placed in soil and gas lines: Gas analysis During all the period of treatment, the gases to be analyzed in the vapour and the exhaust stack are: HCl, (PCE), Oxygen (O2); Carbon monoxide (CO); Carbon dioxide (CO2); Nitrogen oxides (NOx); The sulphur dioxide (SO2) and hydrocarbons HCT. Alarms/Safety •burner temperature (operation: stopping burner when temperature of gas after flame exceed the limit temperature (e.g. 1100°C) and sends sms) •Inlet fan temperature (operation: opening fresh air valve and sends sms) •Electricity off (operation: send sms) Soil temperature dvt 43 Pilot: mass reduction of CVOC’s 44 Results + Target temperature reached after 20 days heating + CVOC’s reduction: > 50 % + No harmful gases emitted + GTR proven as a safe technology 45 – Pilot results – Pumping assays Pumping 3tests oil productivity X7 X2 18 °C 28 °C 0,1 m3/h 0,74 m3/h 45 °C 1,5 m3/h Optimization of pumping performances ! Full scale Installation + 280m² to treat 4,5 m depth + 63 boreholes + 42 heating wells + 19 hexagonal grids – 2.2m interdistance + 19 SVE wells + 5 weeks project duration 47 Installation (2) + Natural gas and electrical connection + Insulation 48 Combustion gas and electrical network 49 FORD Motors: distillation TCE from LNAPL Monitoring 51 Surveillance program + Ambiant air – daily - VOC - Explosivity - O2 - CO - H2S + Ambiant air – sampling campaigns for VOC’s 52 Results air (emissions) Ambiant air Exhaust air 53 Results - Temperatures 54 Results – COVC’s in Oil LNAPL PZ-TD1 PZ-TD2 PZ-TD3 PZ-TD4 55 CLIQUEZ ET MODIFIEZ LE TITRE CONTENT The case Proposed solution Lab study Pilot Full scale Conclusions 56 Conclusions and perspectives + ISTD proven as fractionned distillation technology + Initial characterization essential for accurate timing estimate and planning + Cost efficient TPS TECH International Licenses 58 www.tpstech.com 59