SENSOMATIC OPENING SYSTEM

Transcription

SENSOMATIC OPENING SYSTEM
Sensomatic_ENG:Layout 1
30.04.2009
10:34 Uhr
Seite 1
SENSOMATIC OPENING SYSTEM
Electro-mechanical opening of drawers and pot drawers.
Striking a balance between design and functional comfort.
Sensomatic_ENG:Layout 1
30.04.2009
10:34 Uhr
Seite 2
In an ideal situation, the development
of new movement systems directly
involves the users of the system.
Sensomatic provides the ideal example.
Sensomatic_ENG:Layout 1
30.04.2009
10:34 Uhr
Seite 3
Comfort with a fascinating twist:
it is enough to lightly touch or pull –
and the drawers will open as if by magic.
Fully automatic, electrically powered.
SENSOMATIC OPENING SYSTEM
This electro-mechanical opening system
can be triggered by a light touch or pull
anywhere on the surface of the front which
causes drawers to glide evenly and smoothly.
Thanks to the touch-sensitive Sensomatic device all
you need is a gentle trigger to automatically open
drawers and pot drawers. The action is even, precise
and elegant. And yet, Sensomatic is extremely frugal.
This applies to power consumption as well as space
occupied by the drive unit behind the drawer.
This opening system can be activated by a touch
anywhere on the front of the drawer, which makes
Sensomatic the perfect movement system today,
for the functional requirements of tomorrow.
Likewise, Sensomatic offers ideal solutions for the
furniture designer: the electro-mechanical opening
system allows the use of handle-free surfaces,
clean lines and simple elegance of form. However,
that is not all. Sensomatic makes sure that each
movement offers something for the senses, so that
functional precision also adds an emotional ingredient to your lifestyle. And what an ingredient. The
furniture becomes an expression of your personality,
an element of self-realisation and sensual art.
3
Sensomatic_ENG:Layout 1
30.04.2009
10:34 Uhr
Seite 4
Two devices in one:
Sensomatic, the electro-mechanical opening system,
and Soft-close the mechanical damping system a symbiosis for maximum comfort in all parts of the home.
It has never been easier to open a drawer.
And it has never been easier to close
a drawer. Sensomatic and Soft-close
combine to form a harmonious multifunctional principle. The two systems
combine all advantages of handle-free
opening with the elegance of damped
closing. The combination of these
extraordinary functions guarantees
operating comfort of the highest level.
It is good that there are things that
are made for each other.
4
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 5
One single opening system for all drawer and
slide systems by GRASS. Sensomatic is an
electro-mechanical device with many talents
for modern furniture.
SENSOMATIC OPENING SYSTEM
How about a single opening system for all applications?
We have it here: Sensomatic can be used to open
all GRASS systems. Whether we are talking about
double-walled drawers or wooden drawers.
Nova Pro
DWD-Dynamic-XP
Dynapro
Versatility clearly increases the efficiency of a system.
The same applies to movement systems.
Sensomatic is a highly efficient system
as it needs only one drive unit for all
weight classes and cabinet widths up
to 1,200 mm. But that is not all. This
electro-mechanical opening system
can also be combined with all drawer
and slide systems by GRASS. And
without having to modify the drawers
in question. Likewise, other items
such as wire baskets, refuse separating systems or larder cupboards can
be fitted with the Sensomatic system
without modifications for comfortable
easy opening. In short: Sensomatic
is an electro-mechanical multi-talented
device. Versatile. Efficient. Compelling.
The Sensomatic opening system
is available for GRASS Nova Pro
drawer systems, GRASS DWDDynamic-XP drawer systems and
GRASS Dynapro slide system.
5
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 6
Sensomatic
Table of contents
page
Standard cabinet with horizontal wooden stretcher
Nova Pro construction
6
8
10
DWD-Dynamic-XP construction
12
Dynapro construction
14
Assembly
16
Standard cabinet with vertical wooden stretcher
18
Nova Pro construction
20
DWD-Dynamic-XP construction
22
Dynapro construction
24
Assembly
26
Single drawer with overhead frame set mounting
28
Nova Pro construction
30
DWD-Dynamic-XP construction
32
Dynapro construction
34
Assembly
36
Single drawer with back panel frame set mounting
38
Nova Pro construction
40
DWD-Dynamic-XP construction
42
Dynapro construction
44
Assembly
46
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 7
page
Sink cabinet with bottom panel frame set mounting
48
Nova Pro construction
50
DWD-Dynamic-XP construction
52
Dynapro construction
54
Assembly
56
Sink cabinet with side panel frame set mounting
58
Nova Pro construction
60
DWD-Dynamic-XP construction
62
Assembly
64
Adjustment and dismantling
66
Accessories
68
Front-base connector
4-way-adapter
Synchronisation cable
Drilling template
Technical notes
70
7
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 8
Sensomatic
Standard cabinet with horizontal wooden stretcher
3
4
1
2
7
8
3
4
5
6
Example for ordering:
The following items are needed for a cabinet with 3 drawers:
1
Opening units: 3 No.
5
Power supply unit: 1 No.
2
Frame sides: 1 pair
7
Mains cable: 1 No.
3
Frame connector: 2 No.
8
Front buffers: 10 No.
4
Frame set: 2 No.
Accessories and assembly aides
Adjustment and Dismantling
page 66
Accessories
page 68
8
Technical Information
page 70
Sensomatic_ENG:Layout 1
10:35 Uhr
Seite 9
Opening unit
Item No.
Item No.
for Nova Pro and Dynapro
F121100268217
F121100268607
for DWD-Dynamic-XP
F121100409217
F121100409607
PU 50
PU 10
Flat timber
cross-bar
1
30.04.2009
Frame sides, including frame side cable
3
Length
Item No.
650 mm
F121100284207
750 mm
F121100285207
1170 mm
F121100286207
Frame connector
Item No.
Frame connector
F121100282211
Head assembly
2
Upright timber
cross-bar
PU 50 = 50 pieces, PU 10 = 10 pieces, individually packaged
PU 20
PU 20 = 20 pieces
PU 10
PU 10 = 10 pairs
Power supply unit
Item No.
Item No.
Power supply unit
F121100270211
Connection cable with 2-way-adapter
7
K
Sink cabinet
assembly of base
PU 10 = 10 Stück, individually packaged
PU 20 = 20 pieces
6
F121100269607
PU 10
PU 20
Mains cables
A
E
Length
Item No.
600 mm
F121100288207
Type of plug
Item No.
1000 mm
F121100289207
Mains cable A (DE, ES, F)
69761-04
1600 mm
F121100290207
Mains cable E (DK)
69763-04
2000 mm
F121100291207
Mains cable I (IT)
69764-04
PU 10
Mains cable L (CH)
69765-04
Sink cabinet
assembly of sides
Frame set
Back panel
assembly
5
Fixing brackets, top and bottom
Mains cable K (USA, JP, CA) 69760-04
I
L
D
Mains cable D (G, VAE, MY) 69766-04
PU 10 = 10 pieces
without plug
Adjustment /
Dismantling
4
69767-04
PU 10
PU 10 = 10 pieces
Ø 5 mm
Item No.
Front gap 2,2 mm*
F121100294223
Front gap 3 mm
F121100295223
Front gap 4 mm
F121100296223
Ø 8 mm
Item No.
Front gap 2,2 mm*
F121100297223
Front gap 3 mm
F121100298223
Front gap 4 mm
F121100299223
Accessoiries
Spring-loaded front buffer
Technical
information
8
PU 100
PU 100 = 100 pieces, *for Nova Pro and Dynapro
9
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 10
Standard cabinet with horizontal wooden stretcher
Nova Pro drawer system
Overview
X = min. installation depth
KIB
Y = depth of hole pattern
KIB = internal width of cabinet
X
Y
A
B
A = Frame set top/bottom
B = Frame connector
C
C = Frame sides
B
A
Mounting dimensions
Fixing brackets top/bottom
15
96
Positioning aid
160
52
Ø 10
Ø 5 / 5min.
10
Cable routing
96
Y
X
160
1/2
1/2
KIB
Mounting dimensions Nova Pro
X
Y
Steel back panel
NL + 18
NL + 3
Wood back panel
NL + 20 (+1)
NL + 5 (+1)
NL = nominal length of cabinet slide
All dimensions in millimeters.
10
30.04.2009
10:35 Uhr
Seite 11
Position of opening units Nova Pro
Position of front buffer
Flat timber
cross-bar
Sensomatic_ENG:Layout 1
Ø8 (Ø5) ±0,1
FA / 2
Upright timber
cross-bar
1/2
FH ≤ 300
10
1/2
min. 50
KIB (min. 262)
min. 11
Head assembly
20
FA
Back panel
assembly
FH ≤ 300
KIH
10
TL = KIH - 31
Ø8 (Ø5) ±0,1
20
FA / 2
FA
Sink cabinet
assembly of base
min. 49,5
4-10
min. 11
When fitting the heavy-duty cabinet slide (70 kg)
4 No. front buffers have to be inserted into the front.
200
Do not drive in or glue front buffers.
TL = length of frame side
FH = height of front
KIB = internal width of cabinet
FA = front overlap
Sink cabinet
assembly of sides
KIH = internal height of cabinet
TL = Length of frame side
All dimensions in millimeters.
11
Technical
information
Accessoiries
TL
Adjustment /
Dismantling
Cutting frame side
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 12
Standard cabinet with horizontal wooden stretcher
DWD-Dynamic-XP drawer system
Overview
X = min. installation depth
KIB
Y = depth of hole pattern
KIB = internal width of cabinet
X
Y
A
B
A = Frame set top/bottom
B = Frame connector
C
C = Frame sides
B
A
Mounting dimensions
Fixing brackets top/bottom
15
96
Positioning aid
160
52
Ø 10
Ø 5 / 5min.
10
Cable routing
96
Y
X
160
1/2
1/2
KIB
Mounting dimensions DWD-Dynamic-XP
X
Y
Steel back panel
NL + 13
NL - 2
Wood back panel
NL + 15
NL
NL = nominal length of cabinet slide
All dimensions in millimeters.
12
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 13
Position of front buffer
Flat timber
cross-bar
Position of opening unit DWD-Dynamic-XP
Upright timber
cross-bar
Ø8 (Ø5) ±0,1
FA / 2
min. 11
Ø8 (Ø5) ±0,1
Back panel
assembly
FH ≤ 300
KIH
10
TL = KIH - 31
20
FA
Head assembly
1/2
FH ≤ 300
10
1/2
min. 49
KIB (min. 262)
20
FA / 2
min. 11
min.55
Sink cabinet
assembly of base
5-10
FA
When fitting the heavy-duty cabinet slide (60 kg and 80 kg)
200
4 No. front buffers have to be inserted into the front.
Do not drive in or glue front buffers.
TL = length of frame side
FH = height of front
KIB = internal width of cabinet
FA = front overlap
Sink cabinet
assembly of sides
KIH = internal height of cabinet
TL = Length of frame side
All dimensions in millimeters.
13
Technical
information
Accessoiries
TL
Adjustment /
Dismantling
Cutting frame side
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 14
Standard cabinet with horizontal wooden stretcher
Dynapro slide system
Overview
X = min. installation depth
KIB
Y = depth of hole pattern
KIB = internal width of cabinet
X
Y
A
B
A = Frame set top/bottom
B = Frame connector
C
C = Frame sides
B
A
Mounting dimensions
Fixing brackets top/bottom
15
96
Positioning aid
160
52
Ø 10
Ø 5 / 5min.
10
Cable routing
96
Y
X
160
1/2
1/2
KIB
Mounting dimensions Dynapro
X
Y
NL + 15
NL
NL = nominal length of cabinet slide
All dimensions in millimeters.
14
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 15
Position of front buffer
Flat timber
cross-bar
Position of opening unit Dynapro
1/2
Ø8 (Ø5) ±0,1
Upright timber
cross-bar
15
FH ≤ 300
1/2
min. 64
KIB (min. 312)
FA / 2
min. 11
20
Head assembly
FA
Back panel
assembly
FH ≤ 300
KIH
(min. 88)
15
TL = KIH -31
Ø8 (Ø5) ±0,1
20
FA / 2
FA
min. 37
15
Sink cabinet
assembly of base
min. 11
When fitting the heavy-duty cabinet slide (60 kg)
200
4 No. front buffers have to be inserted into the front.
Do not drive in or glue front buffers.
TL = length of frame side
FH = height of front
KIB = internal width of cabinet
FA = front overlap
Sink cabinet
assembly of sides
KIH = internal height of cabinet
TL = Length of frame side
All dimensions in millimeters.
15
Technical
information
Accessoiries
TL
Adjustment /
Dismantling
Cutting frame side
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 16
Standard cabinet with horizontal wooden stretcher
for Nova Pro, DWD-Dynamic-XP and Dynapro
Assembly
16
Do not drive in or glue front buffers.
Adjustment /
Dismantling
Sink cabinet
assembly of sides
2
Sink cabinet
assembly of base
Back panel
assembly
Head assembly
3
Upright timber
cross-bar
Flat timber
cross-bar
10:35 Uhr
Accessoiries
30.04.2009
Technical
information
Sensomatic_ENG:Layout 1
Seite 17
Wiring
1
Inserting front buffer
17
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 18
Sensomatic
Standard cabinet with vertical wooden stretcher
3
5
1
2
8
9
3
4
6
7
Example for ordering:
The following items are needed for a cabinet with 3 drawers:
1
Opening units: 3 No.
5
Frame set, back: 1 No.
2
Frame sides: 1 pair
6
Power supply unit: 1 No.
3
Frame connector: 2 No.
8
Mains cable: 1 No.
4
Frame set: 1 No.
9
Front buffers: 10 No.
Accessories and assembly aides
Adjustment and Dismantling
page 66
Accessories
page 68
18
Technical Information
page 70
Sensomatic_ENG:Layout 1
10:35 Uhr
Seite 19
Opening unit
Item No.
Item No.
for Nova Pro and Dynapro
F121100268217
F121100268607
for DWD-Dynamic-XP
F121100409217
F121100409607
PU 50
PU 10
Flat timber
cross-bar
1
30.04.2009
Frame sides, including frame side cable
3
Length
Item No.
650 mm
F121100284207
750 mm
F121100285207
1170 mm
F121100286207
Frame connector
Item No.
Frame connector
F121100282211
Head assembly
2
Upright timber
cross-bar
PU 50 = 50 pieces, PU 10 = 10 pieces, individually packaged
PU 20
PU 20 = 20 pieces
PU 10
PU 10 = 10 pairs
5
Frame set bottom
Frame set
Rear-mounting fixing brackets
Item No.
Frame set
Item No.
F121100270211
inside mounted
F121100275207
Back panel
assembly
4
PU 10
PU 20
PU 20 = 20 pieces
back mounted
F121100276207
Sink cabinet
assembly of base
PU 10
PU 10 = 10 pieces
Power supply unit
7
Power supply unit
Connection cable with 2-way-adapter
Item No.
Length
Item No.
F121100269607
600 mm
F121100288207
PU 10
1000 mm
F121100289207
1600 mm
F121100290207
2000 mm
F121100291207
PU 10 = 10 pieces, individually packaged
Sink cabinet
assembly of sides
6
PU 10
I
A
L
E
D
9
Type of plug
Item No.
Spring-loaded front buffer
Ø 5 mm
Item No.
Mains cables K (USA, JP, CA) 69760-04
Front gap 2,2 mm*
F121100294223
Mains cables A (DE, ES, F) 69761-04
Front gap 3 mm
F121100295223
Mains cables E (DK)
69763-04
Front gap 4 mm
F121100296223
Mains cables I (IT)
69764-04
Ø 8 mm
Item No.
Mains cables L (CH)
69765-04
Front gap 2,2 mm*
F121100297223
Mains cables D (G, VAE, MY) 69766-04
Front gap 3 mm
F121100298223
69767-04
Front gap 4 mm
F121100299223
without plug
PU 100
PU 10
PU 10 = 10 pieces
Accessoiries
K
Mains cables
Technical
information
8
Adjustment /
Dismantling
PU 10 = 10 pieces
PU 100 = 100 pieces
*for Nova Pro and Dynapro
19
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 20
Standard cabinet with vertical wooden stretcher
Nova Pro drawer system
Overview
X = min. installation depth
KIB
Y = depth of hole pattern
KIB = internal width of cabinet
X
Y
B
D
A = Frame Set, bottom
B = Frame connector
C
C = Frame sides
D = Frame Set, rear
B
inside or back mounted
A
Mounting dimensions
52
Cable routing
Fixing bracket bottom
5 / 5min.
10
10
96
Positioning aid
96
15
Y
X
160
160
1/2
1/2
KIB
15
Rear-mounting fixing bracket (inside mounted)
96
25
4,5
Rear-mounting fixing bracket (back mounted)
192
Mounting dimensions Nova Pro
X (inside)
X (back)
Y
Steel back panel
Wood back panel
NL + 18
NL + 23
NL + 3
NL + 20 (+1)
NL + 26
NL + 5 (+1)
NL = nominal length of cabinet slide
All dimensions in millimeters.
20
30.04.2009
10:35 Uhr
Seite 21
Position of front buffer
FH ≤ 300
1/2
min. 80
37
Ø8 (Ø5) ±0,1
FA / 2
10
min. 80
min.50
KIB (min. 262)
FA
min. 11
20
10
3
min. 63
KIB (min. 262)
1/2
back mounted
min. 15
inside mounted
Flat timber
cross-bar
Position opening unit Nova Pro
Upright timber
cross-bar
Sensomatic_ENG:Layout 1
Head assembly
FH ≤ 300
TL = KIH - 31
KIH
10
10
TL = KIH -31
KIH
Ø8 (Ø5) ±0,1
200
min. 11
Position of Antriebseinheit Nova Pro
When fitting the heavy-duty cabinet
slide (70 kg), 4 No. front buffers
200
have to be inserted into the front.
Do not drive in or glue front buffers.
TL = length of frame side
FH = height of front
KIB = internal width of cabinet
FA = front overlap
Sink cabinet
assembly of sides
KIH = internal height of cabinet
Sink cabinet
assembly of base
min. 49,5
4-10
min. 49,5
4-10
FA
Back panel
assembly
20
FA / 2
TL = Length of frame side
All dimensions in millimeters.
21
Technical
information
Accessoiries
TL
Adjustment /
Dismantling
Cutting frame side
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 22
Standard cabinet with vertical wooden stretcher
DWD-Dynamic-XP drawer system
Overview
X = min. installation depth
KIB
Y = depth of hole pattern
KIB = internal width of cabinet
X
Y
B
D
A = Frame Set, bottom
B = Frame connector
C
C = Frame sides
D = Frame Set, rear
B
inside or back mounted
A
Mounting dimensions
52
Cable routing
Fixing bracket bottom
5 / 5min.
10
10
96
Positioning aid
96
15
Y
X
160
160
1/2
1/2
KIB
15
Rear-mounting fixing bracket (inside mounted)
96
25
4,5
Rear-mounting fixing bracket (back mounted)
192
Mounting dimensions DWD-Dynamic-XP
X (inside)
X (back)
Y
Steel back panel
NL + 13
NL + 18
NL -2
Wood back panel
NL + 15
NL + 20
NL
NL = nominal length of cabinet slide
All dimensions in millimeters.
22
10:35 Uhr
Seite 23
Position opening unit DWD-Dynamic-XP
Position of front buffer
10
FH ≤ 300
Ø8 (Ø5) ±0,1
FA / 2
1/2
min. 80
37
min. 49
KIB (min. 262)
3
min. 63
KIB (min. 262)
1/2
back mounted
min. 15
inside mounted
Flat timber
cross-bar
30.04.2009
min. 11
Head assembly
Ø8 (Ø5) ±0,1
FH ≤ 300
TL = KIH + X - 15
KIH
10
10
TL = KIH - 31
KIH
20
10
FA
Upright timber
cross-bar
Sensomatic_ENG:Layout 1
min. 55
min. 55
min. 11
When fitting the heavy-duty cabinet
slide (60kg and 80kg), 4 No. front
200
200
buffers have to be inserted into the
front.
Do not drive in or glue front buffers.
TL = length of frame side
FH = height of front
KIB = internal width of cabinet
FA = front overlap
Sink cabinet
assembly of sides
KIH = internal height of cabinet
Back panel
assembly
5-10
5-10
FA
Sink cabinet
assembly of base
20
FA / 2
TL = Length of frame side
All dimensions in millimeters.
23
Technical
information
Accessoiries
TL
Adjustment /
Dismantling
Cutting frame side
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 24
Standard cabinet with vertical wooden stretcher
Dynapro slide-system
Overview
X = min. installation depth
KIB
Y = depth of hole pattern
KIB = internal width of cabinet
X
Y
B
D
A = Frame Set, bottom
B = Frame connector
C
C = Frame sides
D = Frame Set, rear
B
inside or back mounted
A
Mounting dimensions
52
Cable routing
Fixing bracket bottom
5 / 5min.
10
10
96
Positioning aid
96
15
Y
X
160
160
1/2
1/2
KIB
15
Rear-mounting fixing bracket (inside mounted)
96
25
4,5
Rear-mounting fixing bracket (back mounted)
192
Mounting dimensions Dynapro
X (inside)
X (back)
Y
Wood back panel
NL + 15
NL + 20
NL
NL = nominal length of cabinet slide
All dimensions in millimeters.
24
30.04.2009
10:35 Uhr
Seite 25
Position of front buffer
inside mounted
back mounted
FH ≤ 300
1/2
37
min. 80
min. 62
15
15
min. 80
15
3
1/2
KIB (min. 312)
KIB (min. 312)
min. 90
Flat timber
cross-bar
Position opening unit Dynapro
Ø8 (Ø5) ±0,1
FA / 2
min. 11
Head assembly
Ø8 (Ø5) ±0,1
FH ≤ 300
TL = KIH - 31
KIH
15
15
TL = KIH - 31
KIH
20
FA
Upright timber
cross-bar
Sensomatic_ENG:Layout 1
200
min. 11
When fitting the heavy-duty cabinet
200
slide (60 kg), 4 No. front buffers
have to be inserted into the front.
Do not drive in or glue front buffers.
TL = length of frame side
FH = height of front
KIB = internal width of cabinet
FA = front overlap
Sink cabinet
assembly of sides
KIH = internal height of cabinet
Back panel
assembly
min. 37
15
min. 37
15
FA
Sink cabinet
assembly of base
20
FA / 2
TL = Length of frame side
All dimensions in millimeters.
25
Technical
information
Accessoiries
TL
Adjustment /
Dismantling
Cutting frame side
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 26
Standard cabinet with vertical wooden stretcher
for Nova Pro, DWD-Dynamic-XP and Dynapro
Assembly
26
Do not drive in or glue front buffers.
Adjustment /
Dismantling
Sink cabinet
assembly of sides
2
Sink cabinet
assembly of base
Back panel
assembly
Head assembly
3
Upright timber
cross-bar
Flat timber
cross-bar
10:35 Uhr
Accessoiries
30.04.2009
Technical
information
Sensomatic_ENG:Layout 1
Seite 27
Wiring
1
Inserting front buffer
27
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 28
Sensomatic
Single drawer with overhead frame set mounting
2
1
6
5
3
4
Example for ordering:
The following items are needed for a cabinet with one drawer:
1
Opening unit: 1 No.
5
Mains cables: 1 No.
2
Frame Set for head assembly: 1 No.
6
Front buffer: 2 No.
3
Power supply unit : 1 No.
Accessories and assembly aides
Adjustment and Dismantling
page 66
Accessories
page 68
28
Technical Information
page 70
Sensomatic_ENG:Layout 1
10:35 Uhr
Seite 29
Opening unit
Item No.
Item No.
for Nova Pro and Dynapro
F121100268217
F121100268607
for DWD-Dynamic-XP
F121100409217
F121100409607
PU 50
PU 10
Flat timber
cross-bar
1
30.04.2009
Frame set for head assembly
3
Power supply unit
Item No.
Height 120 mm
F121100272207
Height 170 mm
F121100273207
Item No.
Power supply unit
F121100269607
Head assembly
2
Upright timber
cross-bar
PU 50 = 50 pieces, PU 10 = 10 pieces, individually packaged
PU 10
PU 10 = 10 pieces, individually packaged
PU 10
PU 10 = 10 pieces
5
K
Mains cables
A
E
Length
Item No.
600 mm
F121100288207
Type of plug
1000 mm
F121100289207
1600 mm
F121100290207
Mains cables E (DK)
69763-04
2000 mm
F121100291207
Mains cables I (IT)
69764-04
PU 10
Mains cables L (CH)
69765-04
Back panel
assembly
Connection cable with 2-way-adapter
Item No.
Mains cables K (USA, JP, CA) 69760-04
I
L
D
Mains cables A (DE, ES, F) 69761-04
Sink cabinet
assembly of base
4
Mains cables D (G, VAE, MY) 69766-04
PU 10 = 10 pieces
without plug
69767-04
Sink cabinet
assembly of sides
PU 10
PU 10 = 10 pieces
Ø 5 mm
Item No.
Front gap 2,2 mm*
F121100294223
Front gap 3 mm
F121100295223
Front gap 4 mm
F121100296223
Ø 8 mm
Item No.
Front gap 2,2 mm*
F121100297223
Front gap 3 mm
F121100298223
Front gap 4 mm
F121100299223
Adjustment /
Dismantling
Spring-loaded front buffer
PU 100
Accessoiries
PU 100 = 100 pieces
*for Nova Pro and Dynapro
Technical
information
6
29
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 30
Single drawer with overhead frame set mounting
Nova Pro drawer system
Overview
X
Y
X = min. installation depth
KIB
Y = depth of hole pattern
KIB = internal width of cabinet
Überkopfmontage
Frame Set for head assembly
Mounting dimensions
Height 170
Back wall cabling
96
Positioning aid
min. 5
164
7
96
Positioning aid
10
52
Cabinet base
Height 120
96
Positioning aid
32
114
5 / 5min.
96
60
32
15
Y
X
160
1/2
1/2
KIB
160
Mounting dimensions Nova Pro
X
Y
Steel back panel
NL + 18
NL + 3
Wood back panel
NL + 20 (+ 1)
NL + 5 (+1)
NL = nominal length of cabinet slide
All dimensions in millimeters.
30
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Position of front buffer
Flat timber
cross-bar
Position of opening unit Nova Pro
Seite 31
Height 170
Ø8 (Ø5) ±0,1
Upright timber
cross-bar
1/2
FH ≤ 300
1/2
4-10
164
min. 50
max. 108
KIB (min. 262)
FA / 2
min. 11
20
Head assembly
FA
Ø8 (Ø5) ±0,1
Height 120
Back panel
assembly
FH ≤ 300
114
FA / 2
20
4-10
min. 50
max. 58
KIB (min. 262)
FA
Sink cabinet
assembly of base
min. 11
When fitting the heavy-duty cabinet slide (70 kg)
4 No. front buffers have to be inserted into the front.
Sink cabinet
assembly of sides
Do not drive in or glue front buffers.
FH = height of front
Accessoiries
Adjustment /
Dismantling
FA = front overlap
All dimensions in millimeters.
31
Technical
information
KIB = internal width of cabinet
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 32
Single drawer with overhead frame set mounting
DWD-Dynamic-XP drawer system
Overview
X
Y
X = min. installation depth
KIB
Y = depth of hole pattern
KIB = internal width of cabinet
Überkopfmontage
Frame Set for head assembly
Mounting dimensions
Height 170
Back wall cabling
96
Positioning aid
min. 5
164
7
96
Positioning aid
10
52
Cabinet base
Height 120
96
Positioning aid
32
114
5 / 5min.
96
60
32
15
Y
X
160
1/2
1/2
KIB
160
Mounting dimensions DWD-Dynamic-XP
X
Y
Steel back panel
NL + 13
NL - 2
Wood back panel
NL + 15
NL
NL = nominal length of cabinet slide
All dimensions in millimeters.
32
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Position of front buffer
Flat timber
cross-bar
Position of opening unit DWD-Dynamic-XP
Seite 33
Height 170
Upright timber
cross-bar
Ø8 (Ø5) ±0,1
FA / 2
min. 11
20
FA
Head assembly
1/2
FH ≤ 300
1/2
5-10
164
min. 49
max. 107
KIB (min. 262)
Ø8 (Ø5) ±0,1
Height 120
Back panel
assembly
FH ≤ 300
114
5-10
min. 49
max. 56
KIB (min. 262)
20
FA / 2
Sink cabinet
assembly of base
min. 11
When fitting the heavy-duty cabinet slide (60kg and 80kg),
4 No. front buffers have to be inserted into the front.
Sink cabinet
assembly of sides
Do not drive in or glue front buffers.
FH = height of front
Adjustment /
Dismantling
FA = front overlap
Accessoiries
KIB = internal width of cabinet
All dimensions in millimeters.
33
Technical
information
FA
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 34
Single drawer with overhead frame set mounting
Dynapro slide system
Overview
X
Y
X = min. installation depth
KIB
Y = depth of hole pattern
KIB = internal width of cabinet
Überkopfmontage
Frame Set for head assembly
Mounting dimensions
Height 170
Back wall cabling
96
Positioning aid
min. 5
164
7
96
Positioning aid
10
52
Cabinet base
Height 120
96
Positioning aid
32
114
5 / 5min.
96
60
32
15
Y
X
160
1/2
1/2
KIB
160
Mounting dimensions Dynapro
X
Y
Wood back panel
NL + 15
NL
NL = nominal length of cabinet slide
All dimensions in millimeters.
34
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Position of front buffer
Flat timber
cross-bar
Position of opening unit Dynapro
Seite 35
Ø8 (Ø5) ±0,1
Upright timber
cross-bar
1/2
FH ≤ 300
1/2
11 – 15
164
min. 62
max. 122
Height 170
FA / 2
min. 11
20
Head assembly
FA
Ø8 (Ø5) ±0,1
11 – 15
114
Back panel
assembly
FH ≤ 300
KIB (min. 312)
min. 62
max. 72
Height 120
20
FA / 2
FA
Sink cabinet
assembly of base
min. 11
When fitting the heavy-duty cabinet slide (60 kg),
4 No. front buffers have to be inserted into the front.
Sink cabinet
assembly of sides
Do not drive in or glue front buffers.
FH = height of front
Accessoiries
Adjustment /
Dismantling
FA = front overlap
All dimensions in millimeters.
35
Technical
information
KIB = internal width of cabinet
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 36
Single drawer with overhead frame set mounting
for Nova Pro, DWD-Dynamic-XP and Dynapro
Assembly
36
Do not drive in or glue front buffers.
Adjustment /
Dismantling
Sink cabinet
assembly of sides
2
Sink cabinet
assembly of base
Back panel
assembly
Head assembly
3
Upright timber
cross-bar
Flat timber
cross-bar
10:35 Uhr
Accessoiries
30.04.2009
Technical
information
Sensomatic_ENG:Layout 1
Seite 37
Wiring
1
Inserting front buffer
37
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 38
Sensomatic
Single drawer with back panel frame set mounting
1
2
3
7
6
4
5
Example for ordering:
The following items are needed for a cabinet with one drawer:
1
Opening unit: 1 No.
4
2
Frame sides: 1 pair
6
3
Frame connector: 2 No.
7
Power supply unit : 1 No.
Mains cable: 1 No.
Front buffers: 2 No.
Accessories and assembly aides
Adjustment and Dismantling
page 66
Accessories
page 68
38
Technical Information
page 70
Sensomatic_ENG:Layout 1
10:35 Uhr
Seite 39
Opening unit
Item No.
Item No.
für Nova Pro und Dynapro
F121100268217
F121100268607
für DWD-Dynamic-XP
F121100409217
F121100409607
PU 50
PU 10
Flat timber
cross-bar
1
30.04.2009
Frame sides for back panel assembly
3
Frame side pair
Item No.
for 1 No. Drive
F121100283207
Frame connector
Item No.
Frame connector
including hole drilling
Head assembly
2
Upright timber
cross-bar
PU 50 = 50 pieces, PU 10 = 10 pieces, individually packaged
F121100282211
PU 20
PU 20 = 20 pieces
PU 10
Power supply unit
5
Power supply unit
Connection cable with 2-way-adapter
Item No.
Length
Item No.
F121100269607
600 mm
F121100288207
PU 10
1000 mm
F121100289207
1600 mm
F121100290207
2000 mm
F121100291207
PU 10 = 10 pieces, individually packaged
Sink cabinet
assembly of base
4
Back panel
assembly
PU 10 = 10 pairs
PU 10
L
E
D
Type of plug
Item No.
Spring-loaded front buffer
Ø 5 mm
Item No.
Mains cables K (USA, JP, CA) 69760-04
Front gap 2,2 mm*
F121100294223
Mains cables A (DE, ES, F) 69761-04
Front gap 3 mm
F121100295223
Mains cables E (DK)
69763-04
Front gap 4 mm
F121100296223
Mains cables I (IT)
69764-04
Ø 8 mm
Item No.
Mains cables L (CH)
69765-04
Front gap 2,2 mm*
F121100297223
Mains cables D (G, VAE, MY) 69766-04
Front gap 3 mm
F121100298223
69767-04
Front gap 4 mm
F121100299223
without plug
PU 100
PU 10
PU 10 = 10 pieces
Adjustment /
Dismantling
I
A
7
Accessoiries
K
Mains cables
PU 100 = 100 pieces
*for Nova Pro and Dynapro
Technical
information
6
Sink cabinet
assembly of sides
PU 10 = 10 pieces
39
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 40
Single drawer with back panel frame set mounting
Nova Pro drawer system
Overview
X = min. installation depth
KIB
KIB = internal width of cabinet
X
B
A = Frame sides
B = Frame connector
A
Mounting dimensions
Fixing with chipboard screws
ø 3,5 - ø 4 (head diameter max. 8)
9
45
90
164
10
52
X
11
cable routing
1/2
1/2
KIB
Mounting dimensions Nova Pro
X
Steel back panel
NL + 18
Wood back panel
NL + 20 (+1)
NL = nominal length of cabinet slide
All dimensions in millimeters.
40
10:35 Uhr
Flat timber
cross-bar
Position of front buffer
Ø8 (Ø5) ±0,1
FA / 2
Upright timber
cross-bar
FH ≤ 300
Position of opening unit Nova Pro
Seite 41
1/2
30.04.2009
1/2
Sensomatic_ENG:Layout 1
min. 11
FA
Head assembly
min. 50
20
200
min. 3
KIB (min. 262)
Back panel
assembly
min. 3
FH ≤ 300
4-10
90
Ø8 (Ø5) ±0,1
20
FA / 2
FA
Sink cabinet
assembly of base
min. 11
When fitting the heavy-duty cabinet slide (70 kg)
4 No. front buffers have to be inserted into the front.
Sink cabinet
assembly of sides
Do not drive in or glue front buffers.
FH = height of front
Accessoiries
Adjustment /
Dismantling
FA = front overlap
All dimensions in millimeters.
41
Technical
information
KIB = internal width of cabinet
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 42
Single drawer with back panel frame set mounting
DWD-Dynamic-XP drawer system
Overview
X = min. installation depth
KIB
KIB = internal width of cabinet
X
B
A = Frame sides
B = Frame connector
A
Mounting dimensions
Fixing with chipboard screws
ø 3,5 - ø 4 (head diameter max. 8)
9
45
90
164
10
52
X
11
cable routing
1/2
1/2
KIB
Mounting dimensions DWD-Dynamic-XP
X
Steel back panel
NL + 13
Wood back panel
NL + 15
NL = nominal length of cabinet slide
All dimensions in millimeters.
42
10:35 Uhr
Flat timber
cross-bar
Position of front buffer
Ø8 (Ø5) ±0,1
FA / 2
FA
Upright timber
cross-bar
FH ≤ 300
min. 11
20
200
min. 3
KIB (min.262)
min. 3
Head assembly
5-10
FH ≤ 300
90
min. 49
Ø8 (Ø5) ±0,1
20
Back panel
assembly
FA / 2
min. 11
Sink cabinet
assembly of base
FA
When fitting the heavy-duty cabinet slide (60 kg and 80 kg)
4 No. front buffers have to be inserted into the front.
Sink cabinet
assembly of sides
Do not drive in or glue front buffers.
FH = height of front
Adjustment /
Dismantling
FA = front overlap
Accessoiries
KIB = internal width of cabinet
All dimensions in millimeters.
43
Technical
information
Position of opening unit DWD-Dynamic-XP
Seite 43
1/2
30.04.2009
1/2
Sensomatic_ENG:Layout 1
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 44
Single drawer with back panel frame set mounting
Dynapro slide system
Overview
X = min. installation depth
KIB
KIB = internal width of cabinet
X
B
A = Frame sides
B = Frame connector
A
Mounting dimensions
Fixing with chipboard screws
ø 3,5 - ø 4 (head diameter max. 8)
9
45
90
164
10
52
X
11
cable routing
1/2
1/2
KIB
Mounting dimensions Dynapro
X
Wood back panel
NL + 15
NL = nominal length of cabinet slide
All dimensions in millimeters.
44
10:35 Uhr
FA / 2
min. 11
min. 3
FA
20
min. 63
200
Ø8 (Ø5) ±0,1
Upright timber
cross-bar
KIB (min.312)
Flat timber
cross-bar
Position of front buffer
FH ≤ 300
Position of opening unit Dynapro
Seite 45
1/2
30.04.2009
1/2
Sensomatic_ENG:Layout 1
Head assembly
FH ≤ 300
min. 3
15
90
Ø8 (Ø5) ±0,1
20
Back panel
assembly
FA / 2
FA
Sink cabinet
assembly of base
min. 11
When fitting the heavy-duty cabinet slide (60 kg)
4 No. front buffers have to be inserted into the front.
Sink cabinet
assembly of sides
Do not drive in or glue front buffers
FH = height of front
Accessoiries
Adjustment /
Dismantling
FA = front overlap
All dimensions in millimeters.
45
Technical
information
KIB = internal width of cabinet
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 46
Single drawer with back panel frame set mounting
for Nova Pro, DWD-Dynamic-XP and Dynapro
Assembling
46
Do not drive in or glue front buffers.
Adjustment /
Dismantling
Sink cabinet
assembly of sides
2
Sink cabinet
assembly of base
Back panel
assembly
Head assembly
3
Upright timber
cross-bar
Flat timber
cross-bar
10:35 Uhr
Accessoiries
30.04.2009
Technical
information
Sensomatic_ENG:Layout 1
Seite 47
Wiring
1
Inserting front buffer
47
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 48
Sensomatic
Sink cabinet with bottom panel frame set mounting
1
7
2
6
1
2
3
5
4
Example for ordering:
The following items are needed for a cabinet with 2 drawers:
1
Opening units: 2 No.
6
Mains cables: 1 No.
2
Base frame Set: 2 No
7
Front buffers: 8 No.
3
Power supply unit : 1 No.
Accessories and assembly aides
Adjustment and Dismantling
page 66
Accessories
page 68
48
Technical Information
page 70
Sensomatic_ENG:Layout 1
10:35 Uhr
Seite 49
Opening unit
Item No.
Item No.
for Nova Pro and Dynapro
F121100268217
F121100268607
for DWD-Dynamic-XP
F121100409217
F121100409607
PU 50
PU 10
Flat timber
cross-bar
1
30.04.2009
3
Power supply unit
Item No.
Item No.
F121100271207
Power supply unit
PU 10
F121100269607
PU 10
PU 10 = 10 pieces, individually packaged
Connection cable with 2-way-adapter
5
Length
Item No.
600 mm
F121100288207
1000 mm
F121100289207
1600 mm
F121100290207
2000 mm
F121100291207
Back panel
assembly
PU 10 = 10 pieces
4
Head assembly
Base frame set
4-way-adapter
Item No.
4-way-adapter
F121100293207
PU 10
Sink cabinet
assembly of base
2
Upright timber
cross-bar
PU 50 = 50 pieces, PU 10 = 10 pieces, individually packaged
PU 10 = 10 pieces
PU 10
L
E
D
Type of plug
Item No.
Spring-loaded front buffer
Ø 5 mm
Item No.
Mains cables K (USA, JP, CA) 69760-04
Front gap 2,2 mm*
F121100294223
Mains cables A (DE, ES, F) 69761-04
Front gap 3 mm
F121100295223
Mains cables E (DK)
69763-04
Front gap 4 mm
F121100296223
Mains cables I (IT)
69764-04
Ø 8 mm
Item No.
Mains cables L (CH)
69765-04
Front gap 2,2 mm*
F121100297223
Mains cables D (G, VAE, MY) 69766-04
Front gap 3 mm
F121100298223
69767-04
Front gap 4 mm
F121100299223
without plug
PU 100
PU 10
PU 10 = 10 pieces
Adjustment /
Dismantling
I
A
7
PU 100 = 100 pieces
*for Nova Pro and Dynapro
Accessoiries
K
Mains cables
Technical
information
6
Sink cabinet
assembly of sides
PU 10 = 10 pieces
49
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 50
Sink cabinet with bottom panel frame set mounting
Nova Pro drawer system
Overview
X = min. installation depth
Z
Y = depth of hole pattern
Z = depth of hole pattern for sink drawer
X
Y
KIB = internal width of cabinet
KIB
Base frame set
Mounting dimensions
Sink mounting
ø5/ 5min.
96
Positioning aid
160
Z
32
32
60
min. 80
X
min.18
96
positioning aid
160
1/2
1/2
KIB
Base mounting
52
Ø10
min. 213
Ø5 / 5min.
10
Cable routing
32
96
Y
X
NL (B)
NL (A)
160
1/2
1/2
KIB
Mounting dimensions Nova Pro
X
Y
Z
Steel back panel
NL + 18
NL + 3
–
Wood back panel
NL + 20 (+1)
NL + 5 (+1)
NL (A) - NL (B) + 9
NL = nominal length of cabinet slide
All dimensions in millimeters.
50
Flat timber
cross-bar
Position of front buffer
Ø8 (Ø5) ±0,1
FA / 2
Upright timber
cross-bar
FH ≤ 300
Position of opening unit Nova Pro
Seite 51
min. 11
FA
Head assembly
20
4-10
Ø8 (Ø5) ±0,1
Back panel
assembly
FH ≤ 300
min. 51
max. 63
20
FA / 2
FA
Sink cabinet
assembly of base
min. 11
When fitting the heavy-duty cabinet slide (70 kg)
4 No. front buffers have to be inserted into the front.
Sink cabinet
assembly of sides
Do not drive in or glue front buffers.
FH = height of front
FA = front overlap
Adjustment /
Dismantling
KIB = internal width of cabinet
Accessoiries
min. 52
KIB (min.262)
All dimensions in millimeters.
51
Technical
information
10:35 Uhr
1/2
30.04.2009
1/2
Sensomatic_ENG:Layout 1
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 52
Sink cabinet with bottom panel frame set mounting
DWD-Dynamic-XP drawer system
Overview
X = min. installation depth
Z
Y = depth of hole pattern
Z = depth of hole pattern for sink drawer
X
Y
KIB = internal width of cabinet
KIB
Base frame set
Mounting dimensions
Sink mounting
ø5/ 5min.
96
Positioning aid
160
Z
32
32
60
min. 80
X
min.18
96
positioning aid
160
1/2
1/2
KIB
Base mounting
52
Ø10
min. 213
Ø5 / 5min.
10
Cable routing
32
96
Y
X
NL (B)
NL (A)
160
1/2
1/2
KIB
Mounting dimensions DWD-Dynamic-XP
X
Y
Steel back panel
NL + 13
NL - 2
–
Wood back panel
NL + 15
NL
NL (A) - NL (B) + 9
Z
NL = nominal length of cabinet slide
All dimensions in millimeters.
52
Flat timber
cross-bar
Position of front buffer
Ø8 (Ø5) ±0,1
FA / 2
FA
Upright timber
cross-bar
FH ≤ 300
Position of opening unit DWD-Dynamic-XP
Seite 53
min. 11
Head assembly
20
10
Ø8 (Ø5) ±0,1
Back panel
assembly
FH ≤ 300
min. 55
max. 63
20
FA / 2
min. 11
Sink cabinet
assembly of base
FA
When fitting the heavy-duty cabinet slide (60 kg and 80 kg)
4 No. front buffers have to be inserted into the front.
Sink cabinet
assembly of sides
Do not drive in or glue front buffers.
FH = height of front
FA = front overlap
Adjustment /
Dismantling
KIB = internal width of cabinet
Accessoiries
min. 49
KIB (min.262)
All dimensions in millimeters.
53
Technical
information
10:35 Uhr
1/2
30.04.2009
1/2
Sensomatic_ENG:Layout 1
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 54
Sink cabinet with bottom panel frame set mounting
Dynapro slide system
Overview
X = min. installation depth
Z
Y = depth of hole pattern
Z = depth of hole pattern for sink drawer
X
Y
KIB = internal width of cabinet
KIB
Base frame set
Mounting dimensions
Sink mounting
ø5/ 5min.
96
Positioning aid
160
Z
32
32
60
min. 80
X
min.18
96
positioning aid
160
1/2
1/2
KIB
Base mounting
52
Ø10
min. 213
Ø5 / 5min.
10
Cable routing
32
96
Y
X
NL (B)
NL (A)
160
1/2
1/2
KIB
Assembly dimensions Nova Pro
X
Y
X
Wood back panel
NL + 15
NL
NL (A) - NL (B) + 9
NL = nominal length of cabinet slide
All dimensions in millimeters.
54
Flat timber
cross-bar
Position of front buffer
FH ≤ 300
Position of opening unit Dynapro
Seite 55
Ø8 (Ø5) ±0,1
FA / 2
Upright timber
cross-bar
10:35 Uhr
1/2
30.04.2009
1/2
Sensomatic_ENG:Layout 1
min. 11
FA
Head assembly
20
KIB (min.312)
Back panel
assembly
FH ≤ 300
11 - 15
20
FA / 2
FA
Sink cabinet
assembly of base
min. 11
When fitting the heavy-duty cabinet slide (60 kg)
4 No. front buffers have to be inserted into the front.
Sink cabinet
assembly of sides
Do not drive in or glue front buffers.
FH = height of front
Adjustment /
Dismantling
FA = front overlap
Accessoiries
KIB = internal width of cabinet
All dimensions in millimeters.
55
Technical
information
min. 37
max. 46
min. 103
Ø8 (Ø5) ±0,1
Sensomatic_ENG:Layout 1
30.04.2009
10:35 Uhr
Seite 56
Sink cabinet with bottom panel frame set mounting
Nova Pro, DWD-Dynamic-XP and Dynapro
Assembly
56
Do not drive in or glue front buffers.
Adjustment /
Dismantling
Sink cabinet
assembly of sides
2
Sink cabinet
assembly of base
Back panel
assembly
Head assembly
3
Upright timber
cross-bar
Flat timber
cross-bar
10:35 Uhr
Accessoiries
30.04.2009
Technical
information
Sensomatic_ENG:Layout 1
Seite 57
Wiring
1
Inserting front buffer
57
Sensomatic_ENG:Layout 1
30.04.2009
10:36 Uhr
Seite 58
Sensomatic
Sink cabinet with side panel frame set mounting
3
1
7
1
3
8
1
2
4
6
9
5
Example for ordering:
The following items are needed for a cabinet with 2 drawers:
1
Opening units: 3 No.
7
Synchronisation cable: 1 No.
2
Base frame set: 1 No.
8
Mains cables: 1 No.
3
Side frame set: 2 No.
9
Front buffers: 8 No.
4
Power supply unit: 1 No.
Accessories and assembly aides
Adjustment and Dismantling
page 66
Accessories
page 68
58
Technical Information
page 70
Sensomatic_ENG:Layout 1
10:36 Uhr
Seite 59
Opening unit
Item No.
Item No.
for Nova Pro and Dynapro
F121100268217
F121100268607
for DWD-Dynamic-XP
F121100409217
F121100409607
PU 50
PU 10
Flat timber
cross-bar
1
30.04.2009
3
Side frame set
Item No.
Item No.
F121100271207
F121100274207
PU 10
PU 10
PU 10 = 10 pieces
PU 10 = 10 pieces
Power supply unit
5
Power supply unit
Connection cable with 2-way-adapter
Item No.
Length
Item No.
F121100269607
600 mm
F121100288207
PU 10
1000 mm
F121100289207
1600 mm
F121100290207
2000 mm
F121100291207
PU 10 = 10 pieces, individually packaged
Back panel
assembly
4
Head assembly
Base frame set
Sink cabinet
assembly of base
2
Upright timber
cross-bar
PU 50 = 50 pieces, PU 10 = 10 pieces, individually packaged
PU 10
PU 10 = 10 pieces
7
Synchronisation cable
Item No.
Item No.
F121100293207
10 m
PU 10
PU 10
K
I
Mains cables
A
L
E
D
9
Art des Steckers
Item No.
Spring-loaded front buffer
Ø 5 mm
Item No.
Mains cables K (USA, JP, CA) 69760-04
Front gap 2,2 mm*
F121100294223
Mains cables A (DE, ES, F) 69761-04
Front gap 3 mm
F121100295223
Mains cables E (DK)
69763-04
Front gap 4 mm
F121100296223
Mains cables I (IT)
69764-04
Ø 8 mm
Item No.
Mains cables L (CH)
69765-04
Front gap 2,2 mm*
F121100297223
Mains cables D (G, VAE, MY) 69766-04
Front gap 3 mm
F121100298223
69767-04
Front gap 4 mm
F121100299223
without plug
PU 10
PU 10 = 10 pieces
Adjustment /
Dismantling
PU 10 = 10 pieces
PU 10 = 10 pieces
8
F121100287207
Accessoiries
4-way-adapter
Sink cabinet
assembly of sides
4-way-adapter
PU 100
PU 100 = 100 pieces
*for Nova Pro and Dynapro
Technical
information
6
59
Sensomatic_ENG:Layout 1
30.04.2009
10:36 Uhr
Seite 60
Sink cabinet with side panel frame set mounting
Nova Pro drawer system
Overview
X = min. installation depth
KIB
Y = depth of hole pattern
Z
Z = depth of hole pattern
X
Y
for side frame set
KIB = internal width of cabinet
A
A = Side frame set
B = Base frame set
B
Mounting dimensions
Base mounting
Side frame set mounting right
Side frame set mounting left
232
cable routing
ø10
80
32
60
80
160
Cable routing
52
Ø10
105
44
105
44
96
positioning aid
ø10
cable routing
232
Ø5 / 5min.
10
47,5
5 - 11
LBH
Y
X
160
1/2
1/2
Z
KIB
X
Mounting dimensions Nova Pro
X
Y
Z
Steel back panel
NL + 23
NL + 3
NL - 19
Wood back panel
NL + 26
NL + 5 (+1)
NL - 16
NL = nominal length of cabinet slide
NL 300 is not possible.
All dimensions in millimeters.
60
32 32
32
96
30.04.2009
10:36 Uhr
Seite 61
Position of opening unit Nova Pro
Position of front buffer
Flat timber
cross-bar
Sensomatic_ENG:Layout 1
Base assembly
Ø8 (Ø5) ±0,1
FA / 2
min. 11
FA
20
min. 51
max. 63
Upright timber
cross-bar
1/2
1/2
4-10
min. 52
FH ≤ 300
KIB (min.262)
Head assembly
Ø8 (Ø5) ±0,1
Back panel
assembly
FA / 2
20
32
LBH: min. 59
64
32
5-10
FH ≤ 300
Side panel assembly
FA
min. 11
Sink cabinet
assembly of base
LBH
64
When fitting the heavy-duty cabinet slide (70 kg)
4 No. front buffers have to be inserted into the front.
Sink cabinet
assembly of sides
Do not drive in or glue front buffers.
NL - 30 if LBH < 59
FH = height of front
Adjustment /
Dismantling
FA = front overlap
Accessoiries
KIB = internal width of cabinet
All dimensions in millimeters.
61
Technical
information
5
If LBH < 59:
Sensomatic_ENG:Layout 1
30.04.2009
10:36 Uhr
Seite 62
Sink cabinet with side panel frame set mounting
DWD-Dynamic-XP drawer system
Overview
X = min. installation depth
KIB
Y = depth of hole pattern
Z
Z = depth of hole pattern
X
Y
for side frame set
KIB = internal width of cabinet
A
A = Side frame set
B = Base frame set
B
Mounting dimensions
Base mounting
Side frame set mounting right
Side frame set mounting left
232
cable routing
ø10
80
32
60
80
160
Cable routing
52
Ø10
105
44
105
44
96
positioning aid
ø10
cable routing
232
Ø5 / 5min.
5 - 11
LBH
Y
X
160
1/2
1/2
Z
KIB
X
Mounting dimensions DWD-Dynamic-XP
X
Y
Z
NL = nominal length of cabinet slide
Steel back panel
NL + 18
NL - 2
NL - 24
NL 275 and NL 450 (60 kg) are not possible.
Wood back panel
NL + 20
NL
NL - 22
All dimensions in millimeters.
62
32 32
32
10
47,5
96
30.04.2009
10:36 Uhr
Seite 63
Position of opening unit DWD-Dynamic-XP
Position of front buffer
Flat timber
cross-bar
Sensomatic_ENG:Layout 1
Base assembly
Ø8 (Ø5) ±0,1
FA / 2
min. 11
20
FA
Upright timber
cross-bar
1/2
1/2
min. 55
max. 63
10
min. 49
FH ≤ 300
KIB (min.262)
Head assembly
Ø8 (Ø5) ±0,1
Back panel
assembly
FA / 2
20
32
LBH: min. 59
64
32
5-10
FH ≤ 300
Side panel assembly
FA
min. 11
Sink cabinet
assembly of base
LBH
64
When fitting the heavy-duty cabinet slide (60 kg and 80 kg)
4 No. front buffers have to be inserted into the front.
Sink cabinet
assembly of sides
Do not drive in or glue front buffers.
NL - 35 if LBH < 59
FH = height of front
Adjustment /
Dismantling
FA = front overlap
Accessoiries
KIB = internal width of cabinet
All dimensions in millimeters.
63
Technical
information
5
If LBH < 59:
Sensomatic_ENG:Layout 1
30.04.2009
10:36 Uhr
Seite 64
Sink cabinet with side panel frame set mounting
Nova Pro, DWD-Dynamic-XP and Dynapro
Assembly
Strip synchronisation cable.
Insert
synchronisation cable.
Opening unit
64
syn
chr
oni
sat
ion
cab
le
Do not drive in or glue front buffers.
Adjustment /
Dismantling
Sink cabinet
assembly of sides
2
Sink cabinet
assembly of base
Back panel
assembly
Head assembly
Upright timber
cross-bar
Flat timber
cross-bar
10:36 Uhr
Accessoiries
30.04.2009
Technical
information
Sensomatic_ENG:Layout 1
Seite 65
Wiring
3
1
Inserting front buffer
65
Sensomatic_ENG:Layout 1
30.04.2009
10:36 Uhr
Seite 66
Dismantling
Disconnect the power before fitting or dismantling the system.
Dismantling opening unit
Synchronisationskabel
Synchronisationskabel
Dismantling frame sides
1. Insert screwdriver into notches and swivel inwards.
2. Remove frame sides.
66
30.04.2009
10:36 Uhr
Seite 67
Flat timber
cross-bar
Sensomatic_ENG:Layout 1
Synchronisationskabel
Dismantle synchronisation cable
1. Remove opening units from frame sides.
Upright timber
cross-bar
2. Use a pointed object (e.g. a pen or little screw driver)
cab
le
Sink cabinet
assembly of base
Back panel
assembly
syn
chr
oni
sat
ion
Head assembly
to push in white spring and take out cable.
Synchronisationskabel
Adjustment
High
Medium
Technical
information
Low
Accessoiries
Adjustment /
Dismantling
Sink cabinet
assembly of sides
The cabinet must be aligned horizontally.
67
Sensomatic_ENG:Layout 1
30.04.2009
10:36 Uhr
Seite 68
Accessories
Synchronisationskabel
Synchronisation cable
10 m
Item No.
Up to three drive units can be activated at the same
F121100287207
time if they are connected using the synchronisation
PU 10
cable.
PU 10 = 10 pieces
Insert
Strip synchronisation cable.
synchronisation cable.
Opening unit
Synchronisationskabel
4-way-adapter
Item No.
4-way-adapter
F121100293207
PU 10
PU 10 = 10 pieces
68
syn
chr
oni
sat
ion
cab
le
Sensomatic_ENG:Layout 1
30.04.2009
10:36 Uhr
Seite 69
4-way-adapter
Item No.
Item No.
26744-38
26744-09
PU 10
PU 100
Flat timber
cross-bar
Synchronisationskabel
Front-base connector for wide drawers
21
Upright timber
cross-bar
X
1,5 x 45°
Base
Head assembly
Front
(X+8)
16
12,5
8
Ø8
Ø 15
Ø 10
Front
Front
PU 10 = 10 pieces, PU 100 = 100 pieces
13
Tighten cam
Push base and
front together
Back panel
assembly
For a cabinet width of 900 mm and over we recommend the use of
a front/base connector. Where this strong front connection is used
Sink cabinet
assembly of base
it is possible to increase the trigger range also for tall fronts.
X = front overlay at bottom
Sink cabinet
assembly of sides
Drilling template
Item No.
Drilling template
F146109850299
PU 10
Technical
information
Accessoiries
Adjustment /
Dismantling
PU 10 = 10 pieces
69
Sensomatic_ENG:Layout 1
30.04.2009
10:36 Uhr
Seite 70
Technical Information
Synchronisationskabel
General advice
Provide switched sockets.
Disconnect the power before fitting or dismantling the system.
For cabinet widths of 1200 mm and over we recommend the use of 2 No. drive units.
These can be activated simultaneously with the help of the synchronisation cable.
Important: do not insert screws in the area of the drive lever.
With each power supply unit it is possible to operate 30 drive units.
70
Sensomatic_ENG:Layout 1
30.04.2009
10:36 Uhr
Seite 71
Flat timber
cross-bar
Synchronisationskabel
Technical Data
Area of application
Drawer systems
Nova Pro
Dynapro
Area of application
only in dry, closed rooms
Power supply
100 to 240 V
Mains frequency
50 to 60 Hz
Max. power output
230 W
Opening unit
Supply voltage
24 V
Operating conditions
Temperature
0 to 50 °C
Humidity
15% to 90%
Accessoiries
Adjustment /
Dismantling
Sink cabinet
assembly of sides
Sink cabinet
assembly of base
Back panel
assembly
non-condensing
Technical
information
Power supply unit
Head assembly
Slide systems
Upright timber
cross-bar
DWD-Dynamic-XP
71
30.04.2009
10:36 Uhr
Seite 72
F147100527000 – 05|2009 – 5.000 (ENG) – GRASS Advertising Subject to changes, no liability for printing errors excepted.
Sensomatic_ENG:Layout 1
Grass GmbH
Movement-Systems
Grass Platz 1
A 6973 Höchst, Austria
Phone +43 (0) 5578 701-0
Fax
+43 (0) 5578 701-59
E-Mail info@grass.eu