SENSOMATIC OPENING SYSTEM
Transcription
SENSOMATIC OPENING SYSTEM
Sensomatic_ENG:Layout 1 30.04.2009 10:34 Uhr Seite 1 SENSOMATIC OPENING SYSTEM Electro-mechanical opening of drawers and pot drawers. Striking a balance between design and functional comfort. Sensomatic_ENG:Layout 1 30.04.2009 10:34 Uhr Seite 2 In an ideal situation, the development of new movement systems directly involves the users of the system. Sensomatic provides the ideal example. Sensomatic_ENG:Layout 1 30.04.2009 10:34 Uhr Seite 3 Comfort with a fascinating twist: it is enough to lightly touch or pull – and the drawers will open as if by magic. Fully automatic, electrically powered. SENSOMATIC OPENING SYSTEM This electro-mechanical opening system can be triggered by a light touch or pull anywhere on the surface of the front which causes drawers to glide evenly and smoothly. Thanks to the touch-sensitive Sensomatic device all you need is a gentle trigger to automatically open drawers and pot drawers. The action is even, precise and elegant. And yet, Sensomatic is extremely frugal. This applies to power consumption as well as space occupied by the drive unit behind the drawer. This opening system can be activated by a touch anywhere on the front of the drawer, which makes Sensomatic the perfect movement system today, for the functional requirements of tomorrow. Likewise, Sensomatic offers ideal solutions for the furniture designer: the electro-mechanical opening system allows the use of handle-free surfaces, clean lines and simple elegance of form. However, that is not all. Sensomatic makes sure that each movement offers something for the senses, so that functional precision also adds an emotional ingredient to your lifestyle. And what an ingredient. The furniture becomes an expression of your personality, an element of self-realisation and sensual art. 3 Sensomatic_ENG:Layout 1 30.04.2009 10:34 Uhr Seite 4 Two devices in one: Sensomatic, the electro-mechanical opening system, and Soft-close the mechanical damping system a symbiosis for maximum comfort in all parts of the home. It has never been easier to open a drawer. And it has never been easier to close a drawer. Sensomatic and Soft-close combine to form a harmonious multifunctional principle. The two systems combine all advantages of handle-free opening with the elegance of damped closing. The combination of these extraordinary functions guarantees operating comfort of the highest level. It is good that there are things that are made for each other. 4 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 5 One single opening system for all drawer and slide systems by GRASS. Sensomatic is an electro-mechanical device with many talents for modern furniture. SENSOMATIC OPENING SYSTEM How about a single opening system for all applications? We have it here: Sensomatic can be used to open all GRASS systems. Whether we are talking about double-walled drawers or wooden drawers. Nova Pro DWD-Dynamic-XP Dynapro Versatility clearly increases the efficiency of a system. The same applies to movement systems. Sensomatic is a highly efficient system as it needs only one drive unit for all weight classes and cabinet widths up to 1,200 mm. But that is not all. This electro-mechanical opening system can also be combined with all drawer and slide systems by GRASS. And without having to modify the drawers in question. Likewise, other items such as wire baskets, refuse separating systems or larder cupboards can be fitted with the Sensomatic system without modifications for comfortable easy opening. In short: Sensomatic is an electro-mechanical multi-talented device. Versatile. Efficient. Compelling. The Sensomatic opening system is available for GRASS Nova Pro drawer systems, GRASS DWDDynamic-XP drawer systems and GRASS Dynapro slide system. 5 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 6 Sensomatic Table of contents page Standard cabinet with horizontal wooden stretcher Nova Pro construction 6 8 10 DWD-Dynamic-XP construction 12 Dynapro construction 14 Assembly 16 Standard cabinet with vertical wooden stretcher 18 Nova Pro construction 20 DWD-Dynamic-XP construction 22 Dynapro construction 24 Assembly 26 Single drawer with overhead frame set mounting 28 Nova Pro construction 30 DWD-Dynamic-XP construction 32 Dynapro construction 34 Assembly 36 Single drawer with back panel frame set mounting 38 Nova Pro construction 40 DWD-Dynamic-XP construction 42 Dynapro construction 44 Assembly 46 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 7 page Sink cabinet with bottom panel frame set mounting 48 Nova Pro construction 50 DWD-Dynamic-XP construction 52 Dynapro construction 54 Assembly 56 Sink cabinet with side panel frame set mounting 58 Nova Pro construction 60 DWD-Dynamic-XP construction 62 Assembly 64 Adjustment and dismantling 66 Accessories 68 Front-base connector 4-way-adapter Synchronisation cable Drilling template Technical notes 70 7 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 8 Sensomatic Standard cabinet with horizontal wooden stretcher 3 4 1 2 7 8 3 4 5 6 Example for ordering: The following items are needed for a cabinet with 3 drawers: 1 Opening units: 3 No. 5 Power supply unit: 1 No. 2 Frame sides: 1 pair 7 Mains cable: 1 No. 3 Frame connector: 2 No. 8 Front buffers: 10 No. 4 Frame set: 2 No. Accessories and assembly aides Adjustment and Dismantling page 66 Accessories page 68 8 Technical Information page 70 Sensomatic_ENG:Layout 1 10:35 Uhr Seite 9 Opening unit Item No. Item No. for Nova Pro and Dynapro F121100268217 F121100268607 for DWD-Dynamic-XP F121100409217 F121100409607 PU 50 PU 10 Flat timber cross-bar 1 30.04.2009 Frame sides, including frame side cable 3 Length Item No. 650 mm F121100284207 750 mm F121100285207 1170 mm F121100286207 Frame connector Item No. Frame connector F121100282211 Head assembly 2 Upright timber cross-bar PU 50 = 50 pieces, PU 10 = 10 pieces, individually packaged PU 20 PU 20 = 20 pieces PU 10 PU 10 = 10 pairs Power supply unit Item No. Item No. Power supply unit F121100270211 Connection cable with 2-way-adapter 7 K Sink cabinet assembly of base PU 10 = 10 Stück, individually packaged PU 20 = 20 pieces 6 F121100269607 PU 10 PU 20 Mains cables A E Length Item No. 600 mm F121100288207 Type of plug Item No. 1000 mm F121100289207 Mains cable A (DE, ES, F) 69761-04 1600 mm F121100290207 Mains cable E (DK) 69763-04 2000 mm F121100291207 Mains cable I (IT) 69764-04 PU 10 Mains cable L (CH) 69765-04 Sink cabinet assembly of sides Frame set Back panel assembly 5 Fixing brackets, top and bottom Mains cable K (USA, JP, CA) 69760-04 I L D Mains cable D (G, VAE, MY) 69766-04 PU 10 = 10 pieces without plug Adjustment / Dismantling 4 69767-04 PU 10 PU 10 = 10 pieces Ø 5 mm Item No. Front gap 2,2 mm* F121100294223 Front gap 3 mm F121100295223 Front gap 4 mm F121100296223 Ø 8 mm Item No. Front gap 2,2 mm* F121100297223 Front gap 3 mm F121100298223 Front gap 4 mm F121100299223 Accessoiries Spring-loaded front buffer Technical information 8 PU 100 PU 100 = 100 pieces, *for Nova Pro and Dynapro 9 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 10 Standard cabinet with horizontal wooden stretcher Nova Pro drawer system Overview X = min. installation depth KIB Y = depth of hole pattern KIB = internal width of cabinet X Y A B A = Frame set top/bottom B = Frame connector C C = Frame sides B A Mounting dimensions Fixing brackets top/bottom 15 96 Positioning aid 160 52 Ø 10 Ø 5 / 5min. 10 Cable routing 96 Y X 160 1/2 1/2 KIB Mounting dimensions Nova Pro X Y Steel back panel NL + 18 NL + 3 Wood back panel NL + 20 (+1) NL + 5 (+1) NL = nominal length of cabinet slide All dimensions in millimeters. 10 30.04.2009 10:35 Uhr Seite 11 Position of opening units Nova Pro Position of front buffer Flat timber cross-bar Sensomatic_ENG:Layout 1 Ø8 (Ø5) ±0,1 FA / 2 Upright timber cross-bar 1/2 FH ≤ 300 10 1/2 min. 50 KIB (min. 262) min. 11 Head assembly 20 FA Back panel assembly FH ≤ 300 KIH 10 TL = KIH - 31 Ø8 (Ø5) ±0,1 20 FA / 2 FA Sink cabinet assembly of base min. 49,5 4-10 min. 11 When fitting the heavy-duty cabinet slide (70 kg) 4 No. front buffers have to be inserted into the front. 200 Do not drive in or glue front buffers. TL = length of frame side FH = height of front KIB = internal width of cabinet FA = front overlap Sink cabinet assembly of sides KIH = internal height of cabinet TL = Length of frame side All dimensions in millimeters. 11 Technical information Accessoiries TL Adjustment / Dismantling Cutting frame side Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 12 Standard cabinet with horizontal wooden stretcher DWD-Dynamic-XP drawer system Overview X = min. installation depth KIB Y = depth of hole pattern KIB = internal width of cabinet X Y A B A = Frame set top/bottom B = Frame connector C C = Frame sides B A Mounting dimensions Fixing brackets top/bottom 15 96 Positioning aid 160 52 Ø 10 Ø 5 / 5min. 10 Cable routing 96 Y X 160 1/2 1/2 KIB Mounting dimensions DWD-Dynamic-XP X Y Steel back panel NL + 13 NL - 2 Wood back panel NL + 15 NL NL = nominal length of cabinet slide All dimensions in millimeters. 12 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 13 Position of front buffer Flat timber cross-bar Position of opening unit DWD-Dynamic-XP Upright timber cross-bar Ø8 (Ø5) ±0,1 FA / 2 min. 11 Ø8 (Ø5) ±0,1 Back panel assembly FH ≤ 300 KIH 10 TL = KIH - 31 20 FA Head assembly 1/2 FH ≤ 300 10 1/2 min. 49 KIB (min. 262) 20 FA / 2 min. 11 min.55 Sink cabinet assembly of base 5-10 FA When fitting the heavy-duty cabinet slide (60 kg and 80 kg) 200 4 No. front buffers have to be inserted into the front. Do not drive in or glue front buffers. TL = length of frame side FH = height of front KIB = internal width of cabinet FA = front overlap Sink cabinet assembly of sides KIH = internal height of cabinet TL = Length of frame side All dimensions in millimeters. 13 Technical information Accessoiries TL Adjustment / Dismantling Cutting frame side Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 14 Standard cabinet with horizontal wooden stretcher Dynapro slide system Overview X = min. installation depth KIB Y = depth of hole pattern KIB = internal width of cabinet X Y A B A = Frame set top/bottom B = Frame connector C C = Frame sides B A Mounting dimensions Fixing brackets top/bottom 15 96 Positioning aid 160 52 Ø 10 Ø 5 / 5min. 10 Cable routing 96 Y X 160 1/2 1/2 KIB Mounting dimensions Dynapro X Y NL + 15 NL NL = nominal length of cabinet slide All dimensions in millimeters. 14 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 15 Position of front buffer Flat timber cross-bar Position of opening unit Dynapro 1/2 Ø8 (Ø5) ±0,1 Upright timber cross-bar 15 FH ≤ 300 1/2 min. 64 KIB (min. 312) FA / 2 min. 11 20 Head assembly FA Back panel assembly FH ≤ 300 KIH (min. 88) 15 TL = KIH -31 Ø8 (Ø5) ±0,1 20 FA / 2 FA min. 37 15 Sink cabinet assembly of base min. 11 When fitting the heavy-duty cabinet slide (60 kg) 200 4 No. front buffers have to be inserted into the front. Do not drive in or glue front buffers. TL = length of frame side FH = height of front KIB = internal width of cabinet FA = front overlap Sink cabinet assembly of sides KIH = internal height of cabinet TL = Length of frame side All dimensions in millimeters. 15 Technical information Accessoiries TL Adjustment / Dismantling Cutting frame side Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 16 Standard cabinet with horizontal wooden stretcher for Nova Pro, DWD-Dynamic-XP and Dynapro Assembly 16 Do not drive in or glue front buffers. Adjustment / Dismantling Sink cabinet assembly of sides 2 Sink cabinet assembly of base Back panel assembly Head assembly 3 Upright timber cross-bar Flat timber cross-bar 10:35 Uhr Accessoiries 30.04.2009 Technical information Sensomatic_ENG:Layout 1 Seite 17 Wiring 1 Inserting front buffer 17 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 18 Sensomatic Standard cabinet with vertical wooden stretcher 3 5 1 2 8 9 3 4 6 7 Example for ordering: The following items are needed for a cabinet with 3 drawers: 1 Opening units: 3 No. 5 Frame set, back: 1 No. 2 Frame sides: 1 pair 6 Power supply unit: 1 No. 3 Frame connector: 2 No. 8 Mains cable: 1 No. 4 Frame set: 1 No. 9 Front buffers: 10 No. Accessories and assembly aides Adjustment and Dismantling page 66 Accessories page 68 18 Technical Information page 70 Sensomatic_ENG:Layout 1 10:35 Uhr Seite 19 Opening unit Item No. Item No. for Nova Pro and Dynapro F121100268217 F121100268607 for DWD-Dynamic-XP F121100409217 F121100409607 PU 50 PU 10 Flat timber cross-bar 1 30.04.2009 Frame sides, including frame side cable 3 Length Item No. 650 mm F121100284207 750 mm F121100285207 1170 mm F121100286207 Frame connector Item No. Frame connector F121100282211 Head assembly 2 Upright timber cross-bar PU 50 = 50 pieces, PU 10 = 10 pieces, individually packaged PU 20 PU 20 = 20 pieces PU 10 PU 10 = 10 pairs 5 Frame set bottom Frame set Rear-mounting fixing brackets Item No. Frame set Item No. F121100270211 inside mounted F121100275207 Back panel assembly 4 PU 10 PU 20 PU 20 = 20 pieces back mounted F121100276207 Sink cabinet assembly of base PU 10 PU 10 = 10 pieces Power supply unit 7 Power supply unit Connection cable with 2-way-adapter Item No. Length Item No. F121100269607 600 mm F121100288207 PU 10 1000 mm F121100289207 1600 mm F121100290207 2000 mm F121100291207 PU 10 = 10 pieces, individually packaged Sink cabinet assembly of sides 6 PU 10 I A L E D 9 Type of plug Item No. Spring-loaded front buffer Ø 5 mm Item No. Mains cables K (USA, JP, CA) 69760-04 Front gap 2,2 mm* F121100294223 Mains cables A (DE, ES, F) 69761-04 Front gap 3 mm F121100295223 Mains cables E (DK) 69763-04 Front gap 4 mm F121100296223 Mains cables I (IT) 69764-04 Ø 8 mm Item No. Mains cables L (CH) 69765-04 Front gap 2,2 mm* F121100297223 Mains cables D (G, VAE, MY) 69766-04 Front gap 3 mm F121100298223 69767-04 Front gap 4 mm F121100299223 without plug PU 100 PU 10 PU 10 = 10 pieces Accessoiries K Mains cables Technical information 8 Adjustment / Dismantling PU 10 = 10 pieces PU 100 = 100 pieces *for Nova Pro and Dynapro 19 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 20 Standard cabinet with vertical wooden stretcher Nova Pro drawer system Overview X = min. installation depth KIB Y = depth of hole pattern KIB = internal width of cabinet X Y B D A = Frame Set, bottom B = Frame connector C C = Frame sides D = Frame Set, rear B inside or back mounted A Mounting dimensions 52 Cable routing Fixing bracket bottom 5 / 5min. 10 10 96 Positioning aid 96 15 Y X 160 160 1/2 1/2 KIB 15 Rear-mounting fixing bracket (inside mounted) 96 25 4,5 Rear-mounting fixing bracket (back mounted) 192 Mounting dimensions Nova Pro X (inside) X (back) Y Steel back panel Wood back panel NL + 18 NL + 23 NL + 3 NL + 20 (+1) NL + 26 NL + 5 (+1) NL = nominal length of cabinet slide All dimensions in millimeters. 20 30.04.2009 10:35 Uhr Seite 21 Position of front buffer FH ≤ 300 1/2 min. 80 37 Ø8 (Ø5) ±0,1 FA / 2 10 min. 80 min.50 KIB (min. 262) FA min. 11 20 10 3 min. 63 KIB (min. 262) 1/2 back mounted min. 15 inside mounted Flat timber cross-bar Position opening unit Nova Pro Upright timber cross-bar Sensomatic_ENG:Layout 1 Head assembly FH ≤ 300 TL = KIH - 31 KIH 10 10 TL = KIH -31 KIH Ø8 (Ø5) ±0,1 200 min. 11 Position of Antriebseinheit Nova Pro When fitting the heavy-duty cabinet slide (70 kg), 4 No. front buffers 200 have to be inserted into the front. Do not drive in or glue front buffers. TL = length of frame side FH = height of front KIB = internal width of cabinet FA = front overlap Sink cabinet assembly of sides KIH = internal height of cabinet Sink cabinet assembly of base min. 49,5 4-10 min. 49,5 4-10 FA Back panel assembly 20 FA / 2 TL = Length of frame side All dimensions in millimeters. 21 Technical information Accessoiries TL Adjustment / Dismantling Cutting frame side Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 22 Standard cabinet with vertical wooden stretcher DWD-Dynamic-XP drawer system Overview X = min. installation depth KIB Y = depth of hole pattern KIB = internal width of cabinet X Y B D A = Frame Set, bottom B = Frame connector C C = Frame sides D = Frame Set, rear B inside or back mounted A Mounting dimensions 52 Cable routing Fixing bracket bottom 5 / 5min. 10 10 96 Positioning aid 96 15 Y X 160 160 1/2 1/2 KIB 15 Rear-mounting fixing bracket (inside mounted) 96 25 4,5 Rear-mounting fixing bracket (back mounted) 192 Mounting dimensions DWD-Dynamic-XP X (inside) X (back) Y Steel back panel NL + 13 NL + 18 NL -2 Wood back panel NL + 15 NL + 20 NL NL = nominal length of cabinet slide All dimensions in millimeters. 22 10:35 Uhr Seite 23 Position opening unit DWD-Dynamic-XP Position of front buffer 10 FH ≤ 300 Ø8 (Ø5) ±0,1 FA / 2 1/2 min. 80 37 min. 49 KIB (min. 262) 3 min. 63 KIB (min. 262) 1/2 back mounted min. 15 inside mounted Flat timber cross-bar 30.04.2009 min. 11 Head assembly Ø8 (Ø5) ±0,1 FH ≤ 300 TL = KIH + X - 15 KIH 10 10 TL = KIH - 31 KIH 20 10 FA Upright timber cross-bar Sensomatic_ENG:Layout 1 min. 55 min. 55 min. 11 When fitting the heavy-duty cabinet slide (60kg and 80kg), 4 No. front 200 200 buffers have to be inserted into the front. Do not drive in or glue front buffers. TL = length of frame side FH = height of front KIB = internal width of cabinet FA = front overlap Sink cabinet assembly of sides KIH = internal height of cabinet Back panel assembly 5-10 5-10 FA Sink cabinet assembly of base 20 FA / 2 TL = Length of frame side All dimensions in millimeters. 23 Technical information Accessoiries TL Adjustment / Dismantling Cutting frame side Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 24 Standard cabinet with vertical wooden stretcher Dynapro slide-system Overview X = min. installation depth KIB Y = depth of hole pattern KIB = internal width of cabinet X Y B D A = Frame Set, bottom B = Frame connector C C = Frame sides D = Frame Set, rear B inside or back mounted A Mounting dimensions 52 Cable routing Fixing bracket bottom 5 / 5min. 10 10 96 Positioning aid 96 15 Y X 160 160 1/2 1/2 KIB 15 Rear-mounting fixing bracket (inside mounted) 96 25 4,5 Rear-mounting fixing bracket (back mounted) 192 Mounting dimensions Dynapro X (inside) X (back) Y Wood back panel NL + 15 NL + 20 NL NL = nominal length of cabinet slide All dimensions in millimeters. 24 30.04.2009 10:35 Uhr Seite 25 Position of front buffer inside mounted back mounted FH ≤ 300 1/2 37 min. 80 min. 62 15 15 min. 80 15 3 1/2 KIB (min. 312) KIB (min. 312) min. 90 Flat timber cross-bar Position opening unit Dynapro Ø8 (Ø5) ±0,1 FA / 2 min. 11 Head assembly Ø8 (Ø5) ±0,1 FH ≤ 300 TL = KIH - 31 KIH 15 15 TL = KIH - 31 KIH 20 FA Upright timber cross-bar Sensomatic_ENG:Layout 1 200 min. 11 When fitting the heavy-duty cabinet 200 slide (60 kg), 4 No. front buffers have to be inserted into the front. Do not drive in or glue front buffers. TL = length of frame side FH = height of front KIB = internal width of cabinet FA = front overlap Sink cabinet assembly of sides KIH = internal height of cabinet Back panel assembly min. 37 15 min. 37 15 FA Sink cabinet assembly of base 20 FA / 2 TL = Length of frame side All dimensions in millimeters. 25 Technical information Accessoiries TL Adjustment / Dismantling Cutting frame side Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 26 Standard cabinet with vertical wooden stretcher for Nova Pro, DWD-Dynamic-XP and Dynapro Assembly 26 Do not drive in or glue front buffers. Adjustment / Dismantling Sink cabinet assembly of sides 2 Sink cabinet assembly of base Back panel assembly Head assembly 3 Upright timber cross-bar Flat timber cross-bar 10:35 Uhr Accessoiries 30.04.2009 Technical information Sensomatic_ENG:Layout 1 Seite 27 Wiring 1 Inserting front buffer 27 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 28 Sensomatic Single drawer with overhead frame set mounting 2 1 6 5 3 4 Example for ordering: The following items are needed for a cabinet with one drawer: 1 Opening unit: 1 No. 5 Mains cables: 1 No. 2 Frame Set for head assembly: 1 No. 6 Front buffer: 2 No. 3 Power supply unit : 1 No. Accessories and assembly aides Adjustment and Dismantling page 66 Accessories page 68 28 Technical Information page 70 Sensomatic_ENG:Layout 1 10:35 Uhr Seite 29 Opening unit Item No. Item No. for Nova Pro and Dynapro F121100268217 F121100268607 for DWD-Dynamic-XP F121100409217 F121100409607 PU 50 PU 10 Flat timber cross-bar 1 30.04.2009 Frame set for head assembly 3 Power supply unit Item No. Height 120 mm F121100272207 Height 170 mm F121100273207 Item No. Power supply unit F121100269607 Head assembly 2 Upright timber cross-bar PU 50 = 50 pieces, PU 10 = 10 pieces, individually packaged PU 10 PU 10 = 10 pieces, individually packaged PU 10 PU 10 = 10 pieces 5 K Mains cables A E Length Item No. 600 mm F121100288207 Type of plug 1000 mm F121100289207 1600 mm F121100290207 Mains cables E (DK) 69763-04 2000 mm F121100291207 Mains cables I (IT) 69764-04 PU 10 Mains cables L (CH) 69765-04 Back panel assembly Connection cable with 2-way-adapter Item No. Mains cables K (USA, JP, CA) 69760-04 I L D Mains cables A (DE, ES, F) 69761-04 Sink cabinet assembly of base 4 Mains cables D (G, VAE, MY) 69766-04 PU 10 = 10 pieces without plug 69767-04 Sink cabinet assembly of sides PU 10 PU 10 = 10 pieces Ø 5 mm Item No. Front gap 2,2 mm* F121100294223 Front gap 3 mm F121100295223 Front gap 4 mm F121100296223 Ø 8 mm Item No. Front gap 2,2 mm* F121100297223 Front gap 3 mm F121100298223 Front gap 4 mm F121100299223 Adjustment / Dismantling Spring-loaded front buffer PU 100 Accessoiries PU 100 = 100 pieces *for Nova Pro and Dynapro Technical information 6 29 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 30 Single drawer with overhead frame set mounting Nova Pro drawer system Overview X Y X = min. installation depth KIB Y = depth of hole pattern KIB = internal width of cabinet Überkopfmontage Frame Set for head assembly Mounting dimensions Height 170 Back wall cabling 96 Positioning aid min. 5 164 7 96 Positioning aid 10 52 Cabinet base Height 120 96 Positioning aid 32 114 5 / 5min. 96 60 32 15 Y X 160 1/2 1/2 KIB 160 Mounting dimensions Nova Pro X Y Steel back panel NL + 18 NL + 3 Wood back panel NL + 20 (+ 1) NL + 5 (+1) NL = nominal length of cabinet slide All dimensions in millimeters. 30 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Position of front buffer Flat timber cross-bar Position of opening unit Nova Pro Seite 31 Height 170 Ø8 (Ø5) ±0,1 Upright timber cross-bar 1/2 FH ≤ 300 1/2 4-10 164 min. 50 max. 108 KIB (min. 262) FA / 2 min. 11 20 Head assembly FA Ø8 (Ø5) ±0,1 Height 120 Back panel assembly FH ≤ 300 114 FA / 2 20 4-10 min. 50 max. 58 KIB (min. 262) FA Sink cabinet assembly of base min. 11 When fitting the heavy-duty cabinet slide (70 kg) 4 No. front buffers have to be inserted into the front. Sink cabinet assembly of sides Do not drive in or glue front buffers. FH = height of front Accessoiries Adjustment / Dismantling FA = front overlap All dimensions in millimeters. 31 Technical information KIB = internal width of cabinet Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 32 Single drawer with overhead frame set mounting DWD-Dynamic-XP drawer system Overview X Y X = min. installation depth KIB Y = depth of hole pattern KIB = internal width of cabinet Überkopfmontage Frame Set for head assembly Mounting dimensions Height 170 Back wall cabling 96 Positioning aid min. 5 164 7 96 Positioning aid 10 52 Cabinet base Height 120 96 Positioning aid 32 114 5 / 5min. 96 60 32 15 Y X 160 1/2 1/2 KIB 160 Mounting dimensions DWD-Dynamic-XP X Y Steel back panel NL + 13 NL - 2 Wood back panel NL + 15 NL NL = nominal length of cabinet slide All dimensions in millimeters. 32 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Position of front buffer Flat timber cross-bar Position of opening unit DWD-Dynamic-XP Seite 33 Height 170 Upright timber cross-bar Ø8 (Ø5) ±0,1 FA / 2 min. 11 20 FA Head assembly 1/2 FH ≤ 300 1/2 5-10 164 min. 49 max. 107 KIB (min. 262) Ø8 (Ø5) ±0,1 Height 120 Back panel assembly FH ≤ 300 114 5-10 min. 49 max. 56 KIB (min. 262) 20 FA / 2 Sink cabinet assembly of base min. 11 When fitting the heavy-duty cabinet slide (60kg and 80kg), 4 No. front buffers have to be inserted into the front. Sink cabinet assembly of sides Do not drive in or glue front buffers. FH = height of front Adjustment / Dismantling FA = front overlap Accessoiries KIB = internal width of cabinet All dimensions in millimeters. 33 Technical information FA Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 34 Single drawer with overhead frame set mounting Dynapro slide system Overview X Y X = min. installation depth KIB Y = depth of hole pattern KIB = internal width of cabinet Überkopfmontage Frame Set for head assembly Mounting dimensions Height 170 Back wall cabling 96 Positioning aid min. 5 164 7 96 Positioning aid 10 52 Cabinet base Height 120 96 Positioning aid 32 114 5 / 5min. 96 60 32 15 Y X 160 1/2 1/2 KIB 160 Mounting dimensions Dynapro X Y Wood back panel NL + 15 NL NL = nominal length of cabinet slide All dimensions in millimeters. 34 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Position of front buffer Flat timber cross-bar Position of opening unit Dynapro Seite 35 Ø8 (Ø5) ±0,1 Upright timber cross-bar 1/2 FH ≤ 300 1/2 11 – 15 164 min. 62 max. 122 Height 170 FA / 2 min. 11 20 Head assembly FA Ø8 (Ø5) ±0,1 11 – 15 114 Back panel assembly FH ≤ 300 KIB (min. 312) min. 62 max. 72 Height 120 20 FA / 2 FA Sink cabinet assembly of base min. 11 When fitting the heavy-duty cabinet slide (60 kg), 4 No. front buffers have to be inserted into the front. Sink cabinet assembly of sides Do not drive in or glue front buffers. FH = height of front Accessoiries Adjustment / Dismantling FA = front overlap All dimensions in millimeters. 35 Technical information KIB = internal width of cabinet Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 36 Single drawer with overhead frame set mounting for Nova Pro, DWD-Dynamic-XP and Dynapro Assembly 36 Do not drive in or glue front buffers. Adjustment / Dismantling Sink cabinet assembly of sides 2 Sink cabinet assembly of base Back panel assembly Head assembly 3 Upright timber cross-bar Flat timber cross-bar 10:35 Uhr Accessoiries 30.04.2009 Technical information Sensomatic_ENG:Layout 1 Seite 37 Wiring 1 Inserting front buffer 37 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 38 Sensomatic Single drawer with back panel frame set mounting 1 2 3 7 6 4 5 Example for ordering: The following items are needed for a cabinet with one drawer: 1 Opening unit: 1 No. 4 2 Frame sides: 1 pair 6 3 Frame connector: 2 No. 7 Power supply unit : 1 No. Mains cable: 1 No. Front buffers: 2 No. Accessories and assembly aides Adjustment and Dismantling page 66 Accessories page 68 38 Technical Information page 70 Sensomatic_ENG:Layout 1 10:35 Uhr Seite 39 Opening unit Item No. Item No. für Nova Pro und Dynapro F121100268217 F121100268607 für DWD-Dynamic-XP F121100409217 F121100409607 PU 50 PU 10 Flat timber cross-bar 1 30.04.2009 Frame sides for back panel assembly 3 Frame side pair Item No. for 1 No. Drive F121100283207 Frame connector Item No. Frame connector including hole drilling Head assembly 2 Upright timber cross-bar PU 50 = 50 pieces, PU 10 = 10 pieces, individually packaged F121100282211 PU 20 PU 20 = 20 pieces PU 10 Power supply unit 5 Power supply unit Connection cable with 2-way-adapter Item No. Length Item No. F121100269607 600 mm F121100288207 PU 10 1000 mm F121100289207 1600 mm F121100290207 2000 mm F121100291207 PU 10 = 10 pieces, individually packaged Sink cabinet assembly of base 4 Back panel assembly PU 10 = 10 pairs PU 10 L E D Type of plug Item No. Spring-loaded front buffer Ø 5 mm Item No. Mains cables K (USA, JP, CA) 69760-04 Front gap 2,2 mm* F121100294223 Mains cables A (DE, ES, F) 69761-04 Front gap 3 mm F121100295223 Mains cables E (DK) 69763-04 Front gap 4 mm F121100296223 Mains cables I (IT) 69764-04 Ø 8 mm Item No. Mains cables L (CH) 69765-04 Front gap 2,2 mm* F121100297223 Mains cables D (G, VAE, MY) 69766-04 Front gap 3 mm F121100298223 69767-04 Front gap 4 mm F121100299223 without plug PU 100 PU 10 PU 10 = 10 pieces Adjustment / Dismantling I A 7 Accessoiries K Mains cables PU 100 = 100 pieces *for Nova Pro and Dynapro Technical information 6 Sink cabinet assembly of sides PU 10 = 10 pieces 39 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 40 Single drawer with back panel frame set mounting Nova Pro drawer system Overview X = min. installation depth KIB KIB = internal width of cabinet X B A = Frame sides B = Frame connector A Mounting dimensions Fixing with chipboard screws ø 3,5 - ø 4 (head diameter max. 8) 9 45 90 164 10 52 X 11 cable routing 1/2 1/2 KIB Mounting dimensions Nova Pro X Steel back panel NL + 18 Wood back panel NL + 20 (+1) NL = nominal length of cabinet slide All dimensions in millimeters. 40 10:35 Uhr Flat timber cross-bar Position of front buffer Ø8 (Ø5) ±0,1 FA / 2 Upright timber cross-bar FH ≤ 300 Position of opening unit Nova Pro Seite 41 1/2 30.04.2009 1/2 Sensomatic_ENG:Layout 1 min. 11 FA Head assembly min. 50 20 200 min. 3 KIB (min. 262) Back panel assembly min. 3 FH ≤ 300 4-10 90 Ø8 (Ø5) ±0,1 20 FA / 2 FA Sink cabinet assembly of base min. 11 When fitting the heavy-duty cabinet slide (70 kg) 4 No. front buffers have to be inserted into the front. Sink cabinet assembly of sides Do not drive in or glue front buffers. FH = height of front Accessoiries Adjustment / Dismantling FA = front overlap All dimensions in millimeters. 41 Technical information KIB = internal width of cabinet Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 42 Single drawer with back panel frame set mounting DWD-Dynamic-XP drawer system Overview X = min. installation depth KIB KIB = internal width of cabinet X B A = Frame sides B = Frame connector A Mounting dimensions Fixing with chipboard screws ø 3,5 - ø 4 (head diameter max. 8) 9 45 90 164 10 52 X 11 cable routing 1/2 1/2 KIB Mounting dimensions DWD-Dynamic-XP X Steel back panel NL + 13 Wood back panel NL + 15 NL = nominal length of cabinet slide All dimensions in millimeters. 42 10:35 Uhr Flat timber cross-bar Position of front buffer Ø8 (Ø5) ±0,1 FA / 2 FA Upright timber cross-bar FH ≤ 300 min. 11 20 200 min. 3 KIB (min.262) min. 3 Head assembly 5-10 FH ≤ 300 90 min. 49 Ø8 (Ø5) ±0,1 20 Back panel assembly FA / 2 min. 11 Sink cabinet assembly of base FA When fitting the heavy-duty cabinet slide (60 kg and 80 kg) 4 No. front buffers have to be inserted into the front. Sink cabinet assembly of sides Do not drive in or glue front buffers. FH = height of front Adjustment / Dismantling FA = front overlap Accessoiries KIB = internal width of cabinet All dimensions in millimeters. 43 Technical information Position of opening unit DWD-Dynamic-XP Seite 43 1/2 30.04.2009 1/2 Sensomatic_ENG:Layout 1 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 44 Single drawer with back panel frame set mounting Dynapro slide system Overview X = min. installation depth KIB KIB = internal width of cabinet X B A = Frame sides B = Frame connector A Mounting dimensions Fixing with chipboard screws ø 3,5 - ø 4 (head diameter max. 8) 9 45 90 164 10 52 X 11 cable routing 1/2 1/2 KIB Mounting dimensions Dynapro X Wood back panel NL + 15 NL = nominal length of cabinet slide All dimensions in millimeters. 44 10:35 Uhr FA / 2 min. 11 min. 3 FA 20 min. 63 200 Ø8 (Ø5) ±0,1 Upright timber cross-bar KIB (min.312) Flat timber cross-bar Position of front buffer FH ≤ 300 Position of opening unit Dynapro Seite 45 1/2 30.04.2009 1/2 Sensomatic_ENG:Layout 1 Head assembly FH ≤ 300 min. 3 15 90 Ø8 (Ø5) ±0,1 20 Back panel assembly FA / 2 FA Sink cabinet assembly of base min. 11 When fitting the heavy-duty cabinet slide (60 kg) 4 No. front buffers have to be inserted into the front. Sink cabinet assembly of sides Do not drive in or glue front buffers FH = height of front Accessoiries Adjustment / Dismantling FA = front overlap All dimensions in millimeters. 45 Technical information KIB = internal width of cabinet Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 46 Single drawer with back panel frame set mounting for Nova Pro, DWD-Dynamic-XP and Dynapro Assembling 46 Do not drive in or glue front buffers. Adjustment / Dismantling Sink cabinet assembly of sides 2 Sink cabinet assembly of base Back panel assembly Head assembly 3 Upright timber cross-bar Flat timber cross-bar 10:35 Uhr Accessoiries 30.04.2009 Technical information Sensomatic_ENG:Layout 1 Seite 47 Wiring 1 Inserting front buffer 47 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 48 Sensomatic Sink cabinet with bottom panel frame set mounting 1 7 2 6 1 2 3 5 4 Example for ordering: The following items are needed for a cabinet with 2 drawers: 1 Opening units: 2 No. 6 Mains cables: 1 No. 2 Base frame Set: 2 No 7 Front buffers: 8 No. 3 Power supply unit : 1 No. Accessories and assembly aides Adjustment and Dismantling page 66 Accessories page 68 48 Technical Information page 70 Sensomatic_ENG:Layout 1 10:35 Uhr Seite 49 Opening unit Item No. Item No. for Nova Pro and Dynapro F121100268217 F121100268607 for DWD-Dynamic-XP F121100409217 F121100409607 PU 50 PU 10 Flat timber cross-bar 1 30.04.2009 3 Power supply unit Item No. Item No. F121100271207 Power supply unit PU 10 F121100269607 PU 10 PU 10 = 10 pieces, individually packaged Connection cable with 2-way-adapter 5 Length Item No. 600 mm F121100288207 1000 mm F121100289207 1600 mm F121100290207 2000 mm F121100291207 Back panel assembly PU 10 = 10 pieces 4 Head assembly Base frame set 4-way-adapter Item No. 4-way-adapter F121100293207 PU 10 Sink cabinet assembly of base 2 Upright timber cross-bar PU 50 = 50 pieces, PU 10 = 10 pieces, individually packaged PU 10 = 10 pieces PU 10 L E D Type of plug Item No. Spring-loaded front buffer Ø 5 mm Item No. Mains cables K (USA, JP, CA) 69760-04 Front gap 2,2 mm* F121100294223 Mains cables A (DE, ES, F) 69761-04 Front gap 3 mm F121100295223 Mains cables E (DK) 69763-04 Front gap 4 mm F121100296223 Mains cables I (IT) 69764-04 Ø 8 mm Item No. Mains cables L (CH) 69765-04 Front gap 2,2 mm* F121100297223 Mains cables D (G, VAE, MY) 69766-04 Front gap 3 mm F121100298223 69767-04 Front gap 4 mm F121100299223 without plug PU 100 PU 10 PU 10 = 10 pieces Adjustment / Dismantling I A 7 PU 100 = 100 pieces *for Nova Pro and Dynapro Accessoiries K Mains cables Technical information 6 Sink cabinet assembly of sides PU 10 = 10 pieces 49 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 50 Sink cabinet with bottom panel frame set mounting Nova Pro drawer system Overview X = min. installation depth Z Y = depth of hole pattern Z = depth of hole pattern for sink drawer X Y KIB = internal width of cabinet KIB Base frame set Mounting dimensions Sink mounting ø5/ 5min. 96 Positioning aid 160 Z 32 32 60 min. 80 X min.18 96 positioning aid 160 1/2 1/2 KIB Base mounting 52 Ø10 min. 213 Ø5 / 5min. 10 Cable routing 32 96 Y X NL (B) NL (A) 160 1/2 1/2 KIB Mounting dimensions Nova Pro X Y Z Steel back panel NL + 18 NL + 3 – Wood back panel NL + 20 (+1) NL + 5 (+1) NL (A) - NL (B) + 9 NL = nominal length of cabinet slide All dimensions in millimeters. 50 Flat timber cross-bar Position of front buffer Ø8 (Ø5) ±0,1 FA / 2 Upright timber cross-bar FH ≤ 300 Position of opening unit Nova Pro Seite 51 min. 11 FA Head assembly 20 4-10 Ø8 (Ø5) ±0,1 Back panel assembly FH ≤ 300 min. 51 max. 63 20 FA / 2 FA Sink cabinet assembly of base min. 11 When fitting the heavy-duty cabinet slide (70 kg) 4 No. front buffers have to be inserted into the front. Sink cabinet assembly of sides Do not drive in or glue front buffers. FH = height of front FA = front overlap Adjustment / Dismantling KIB = internal width of cabinet Accessoiries min. 52 KIB (min.262) All dimensions in millimeters. 51 Technical information 10:35 Uhr 1/2 30.04.2009 1/2 Sensomatic_ENG:Layout 1 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 52 Sink cabinet with bottom panel frame set mounting DWD-Dynamic-XP drawer system Overview X = min. installation depth Z Y = depth of hole pattern Z = depth of hole pattern for sink drawer X Y KIB = internal width of cabinet KIB Base frame set Mounting dimensions Sink mounting ø5/ 5min. 96 Positioning aid 160 Z 32 32 60 min. 80 X min.18 96 positioning aid 160 1/2 1/2 KIB Base mounting 52 Ø10 min. 213 Ø5 / 5min. 10 Cable routing 32 96 Y X NL (B) NL (A) 160 1/2 1/2 KIB Mounting dimensions DWD-Dynamic-XP X Y Steel back panel NL + 13 NL - 2 – Wood back panel NL + 15 NL NL (A) - NL (B) + 9 Z NL = nominal length of cabinet slide All dimensions in millimeters. 52 Flat timber cross-bar Position of front buffer Ø8 (Ø5) ±0,1 FA / 2 FA Upright timber cross-bar FH ≤ 300 Position of opening unit DWD-Dynamic-XP Seite 53 min. 11 Head assembly 20 10 Ø8 (Ø5) ±0,1 Back panel assembly FH ≤ 300 min. 55 max. 63 20 FA / 2 min. 11 Sink cabinet assembly of base FA When fitting the heavy-duty cabinet slide (60 kg and 80 kg) 4 No. front buffers have to be inserted into the front. Sink cabinet assembly of sides Do not drive in or glue front buffers. FH = height of front FA = front overlap Adjustment / Dismantling KIB = internal width of cabinet Accessoiries min. 49 KIB (min.262) All dimensions in millimeters. 53 Technical information 10:35 Uhr 1/2 30.04.2009 1/2 Sensomatic_ENG:Layout 1 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 54 Sink cabinet with bottom panel frame set mounting Dynapro slide system Overview X = min. installation depth Z Y = depth of hole pattern Z = depth of hole pattern for sink drawer X Y KIB = internal width of cabinet KIB Base frame set Mounting dimensions Sink mounting ø5/ 5min. 96 Positioning aid 160 Z 32 32 60 min. 80 X min.18 96 positioning aid 160 1/2 1/2 KIB Base mounting 52 Ø10 min. 213 Ø5 / 5min. 10 Cable routing 32 96 Y X NL (B) NL (A) 160 1/2 1/2 KIB Assembly dimensions Nova Pro X Y X Wood back panel NL + 15 NL NL (A) - NL (B) + 9 NL = nominal length of cabinet slide All dimensions in millimeters. 54 Flat timber cross-bar Position of front buffer FH ≤ 300 Position of opening unit Dynapro Seite 55 Ø8 (Ø5) ±0,1 FA / 2 Upright timber cross-bar 10:35 Uhr 1/2 30.04.2009 1/2 Sensomatic_ENG:Layout 1 min. 11 FA Head assembly 20 KIB (min.312) Back panel assembly FH ≤ 300 11 - 15 20 FA / 2 FA Sink cabinet assembly of base min. 11 When fitting the heavy-duty cabinet slide (60 kg) 4 No. front buffers have to be inserted into the front. Sink cabinet assembly of sides Do not drive in or glue front buffers. FH = height of front Adjustment / Dismantling FA = front overlap Accessoiries KIB = internal width of cabinet All dimensions in millimeters. 55 Technical information min. 37 max. 46 min. 103 Ø8 (Ø5) ±0,1 Sensomatic_ENG:Layout 1 30.04.2009 10:35 Uhr Seite 56 Sink cabinet with bottom panel frame set mounting Nova Pro, DWD-Dynamic-XP and Dynapro Assembly 56 Do not drive in or glue front buffers. Adjustment / Dismantling Sink cabinet assembly of sides 2 Sink cabinet assembly of base Back panel assembly Head assembly 3 Upright timber cross-bar Flat timber cross-bar 10:35 Uhr Accessoiries 30.04.2009 Technical information Sensomatic_ENG:Layout 1 Seite 57 Wiring 1 Inserting front buffer 57 Sensomatic_ENG:Layout 1 30.04.2009 10:36 Uhr Seite 58 Sensomatic Sink cabinet with side panel frame set mounting 3 1 7 1 3 8 1 2 4 6 9 5 Example for ordering: The following items are needed for a cabinet with 2 drawers: 1 Opening units: 3 No. 7 Synchronisation cable: 1 No. 2 Base frame set: 1 No. 8 Mains cables: 1 No. 3 Side frame set: 2 No. 9 Front buffers: 8 No. 4 Power supply unit: 1 No. Accessories and assembly aides Adjustment and Dismantling page 66 Accessories page 68 58 Technical Information page 70 Sensomatic_ENG:Layout 1 10:36 Uhr Seite 59 Opening unit Item No. Item No. for Nova Pro and Dynapro F121100268217 F121100268607 for DWD-Dynamic-XP F121100409217 F121100409607 PU 50 PU 10 Flat timber cross-bar 1 30.04.2009 3 Side frame set Item No. Item No. F121100271207 F121100274207 PU 10 PU 10 PU 10 = 10 pieces PU 10 = 10 pieces Power supply unit 5 Power supply unit Connection cable with 2-way-adapter Item No. Length Item No. F121100269607 600 mm F121100288207 PU 10 1000 mm F121100289207 1600 mm F121100290207 2000 mm F121100291207 PU 10 = 10 pieces, individually packaged Back panel assembly 4 Head assembly Base frame set Sink cabinet assembly of base 2 Upright timber cross-bar PU 50 = 50 pieces, PU 10 = 10 pieces, individually packaged PU 10 PU 10 = 10 pieces 7 Synchronisation cable Item No. Item No. F121100293207 10 m PU 10 PU 10 K I Mains cables A L E D 9 Art des Steckers Item No. Spring-loaded front buffer Ø 5 mm Item No. Mains cables K (USA, JP, CA) 69760-04 Front gap 2,2 mm* F121100294223 Mains cables A (DE, ES, F) 69761-04 Front gap 3 mm F121100295223 Mains cables E (DK) 69763-04 Front gap 4 mm F121100296223 Mains cables I (IT) 69764-04 Ø 8 mm Item No. Mains cables L (CH) 69765-04 Front gap 2,2 mm* F121100297223 Mains cables D (G, VAE, MY) 69766-04 Front gap 3 mm F121100298223 69767-04 Front gap 4 mm F121100299223 without plug PU 10 PU 10 = 10 pieces Adjustment / Dismantling PU 10 = 10 pieces PU 10 = 10 pieces 8 F121100287207 Accessoiries 4-way-adapter Sink cabinet assembly of sides 4-way-adapter PU 100 PU 100 = 100 pieces *for Nova Pro and Dynapro Technical information 6 59 Sensomatic_ENG:Layout 1 30.04.2009 10:36 Uhr Seite 60 Sink cabinet with side panel frame set mounting Nova Pro drawer system Overview X = min. installation depth KIB Y = depth of hole pattern Z Z = depth of hole pattern X Y for side frame set KIB = internal width of cabinet A A = Side frame set B = Base frame set B Mounting dimensions Base mounting Side frame set mounting right Side frame set mounting left 232 cable routing ø10 80 32 60 80 160 Cable routing 52 Ø10 105 44 105 44 96 positioning aid ø10 cable routing 232 Ø5 / 5min. 10 47,5 5 - 11 LBH Y X 160 1/2 1/2 Z KIB X Mounting dimensions Nova Pro X Y Z Steel back panel NL + 23 NL + 3 NL - 19 Wood back panel NL + 26 NL + 5 (+1) NL - 16 NL = nominal length of cabinet slide NL 300 is not possible. All dimensions in millimeters. 60 32 32 32 96 30.04.2009 10:36 Uhr Seite 61 Position of opening unit Nova Pro Position of front buffer Flat timber cross-bar Sensomatic_ENG:Layout 1 Base assembly Ø8 (Ø5) ±0,1 FA / 2 min. 11 FA 20 min. 51 max. 63 Upright timber cross-bar 1/2 1/2 4-10 min. 52 FH ≤ 300 KIB (min.262) Head assembly Ø8 (Ø5) ±0,1 Back panel assembly FA / 2 20 32 LBH: min. 59 64 32 5-10 FH ≤ 300 Side panel assembly FA min. 11 Sink cabinet assembly of base LBH 64 When fitting the heavy-duty cabinet slide (70 kg) 4 No. front buffers have to be inserted into the front. Sink cabinet assembly of sides Do not drive in or glue front buffers. NL - 30 if LBH < 59 FH = height of front Adjustment / Dismantling FA = front overlap Accessoiries KIB = internal width of cabinet All dimensions in millimeters. 61 Technical information 5 If LBH < 59: Sensomatic_ENG:Layout 1 30.04.2009 10:36 Uhr Seite 62 Sink cabinet with side panel frame set mounting DWD-Dynamic-XP drawer system Overview X = min. installation depth KIB Y = depth of hole pattern Z Z = depth of hole pattern X Y for side frame set KIB = internal width of cabinet A A = Side frame set B = Base frame set B Mounting dimensions Base mounting Side frame set mounting right Side frame set mounting left 232 cable routing ø10 80 32 60 80 160 Cable routing 52 Ø10 105 44 105 44 96 positioning aid ø10 cable routing 232 Ø5 / 5min. 5 - 11 LBH Y X 160 1/2 1/2 Z KIB X Mounting dimensions DWD-Dynamic-XP X Y Z NL = nominal length of cabinet slide Steel back panel NL + 18 NL - 2 NL - 24 NL 275 and NL 450 (60 kg) are not possible. Wood back panel NL + 20 NL NL - 22 All dimensions in millimeters. 62 32 32 32 10 47,5 96 30.04.2009 10:36 Uhr Seite 63 Position of opening unit DWD-Dynamic-XP Position of front buffer Flat timber cross-bar Sensomatic_ENG:Layout 1 Base assembly Ø8 (Ø5) ±0,1 FA / 2 min. 11 20 FA Upright timber cross-bar 1/2 1/2 min. 55 max. 63 10 min. 49 FH ≤ 300 KIB (min.262) Head assembly Ø8 (Ø5) ±0,1 Back panel assembly FA / 2 20 32 LBH: min. 59 64 32 5-10 FH ≤ 300 Side panel assembly FA min. 11 Sink cabinet assembly of base LBH 64 When fitting the heavy-duty cabinet slide (60 kg and 80 kg) 4 No. front buffers have to be inserted into the front. Sink cabinet assembly of sides Do not drive in or glue front buffers. NL - 35 if LBH < 59 FH = height of front Adjustment / Dismantling FA = front overlap Accessoiries KIB = internal width of cabinet All dimensions in millimeters. 63 Technical information 5 If LBH < 59: Sensomatic_ENG:Layout 1 30.04.2009 10:36 Uhr Seite 64 Sink cabinet with side panel frame set mounting Nova Pro, DWD-Dynamic-XP and Dynapro Assembly Strip synchronisation cable. Insert synchronisation cable. Opening unit 64 syn chr oni sat ion cab le Do not drive in or glue front buffers. Adjustment / Dismantling Sink cabinet assembly of sides 2 Sink cabinet assembly of base Back panel assembly Head assembly Upright timber cross-bar Flat timber cross-bar 10:36 Uhr Accessoiries 30.04.2009 Technical information Sensomatic_ENG:Layout 1 Seite 65 Wiring 3 1 Inserting front buffer 65 Sensomatic_ENG:Layout 1 30.04.2009 10:36 Uhr Seite 66 Dismantling Disconnect the power before fitting or dismantling the system. Dismantling opening unit Synchronisationskabel Synchronisationskabel Dismantling frame sides 1. Insert screwdriver into notches and swivel inwards. 2. Remove frame sides. 66 30.04.2009 10:36 Uhr Seite 67 Flat timber cross-bar Sensomatic_ENG:Layout 1 Synchronisationskabel Dismantle synchronisation cable 1. Remove opening units from frame sides. Upright timber cross-bar 2. Use a pointed object (e.g. a pen or little screw driver) cab le Sink cabinet assembly of base Back panel assembly syn chr oni sat ion Head assembly to push in white spring and take out cable. Synchronisationskabel Adjustment High Medium Technical information Low Accessoiries Adjustment / Dismantling Sink cabinet assembly of sides The cabinet must be aligned horizontally. 67 Sensomatic_ENG:Layout 1 30.04.2009 10:36 Uhr Seite 68 Accessories Synchronisationskabel Synchronisation cable 10 m Item No. Up to three drive units can be activated at the same F121100287207 time if they are connected using the synchronisation PU 10 cable. PU 10 = 10 pieces Insert Strip synchronisation cable. synchronisation cable. Opening unit Synchronisationskabel 4-way-adapter Item No. 4-way-adapter F121100293207 PU 10 PU 10 = 10 pieces 68 syn chr oni sat ion cab le Sensomatic_ENG:Layout 1 30.04.2009 10:36 Uhr Seite 69 4-way-adapter Item No. Item No. 26744-38 26744-09 PU 10 PU 100 Flat timber cross-bar Synchronisationskabel Front-base connector for wide drawers 21 Upright timber cross-bar X 1,5 x 45° Base Head assembly Front (X+8) 16 12,5 8 Ø8 Ø 15 Ø 10 Front Front PU 10 = 10 pieces, PU 100 = 100 pieces 13 Tighten cam Push base and front together Back panel assembly For a cabinet width of 900 mm and over we recommend the use of a front/base connector. Where this strong front connection is used Sink cabinet assembly of base it is possible to increase the trigger range also for tall fronts. X = front overlay at bottom Sink cabinet assembly of sides Drilling template Item No. Drilling template F146109850299 PU 10 Technical information Accessoiries Adjustment / Dismantling PU 10 = 10 pieces 69 Sensomatic_ENG:Layout 1 30.04.2009 10:36 Uhr Seite 70 Technical Information Synchronisationskabel General advice Provide switched sockets. Disconnect the power before fitting or dismantling the system. For cabinet widths of 1200 mm and over we recommend the use of 2 No. drive units. These can be activated simultaneously with the help of the synchronisation cable. Important: do not insert screws in the area of the drive lever. With each power supply unit it is possible to operate 30 drive units. 70 Sensomatic_ENG:Layout 1 30.04.2009 10:36 Uhr Seite 71 Flat timber cross-bar Synchronisationskabel Technical Data Area of application Drawer systems Nova Pro Dynapro Area of application only in dry, closed rooms Power supply 100 to 240 V Mains frequency 50 to 60 Hz Max. power output 230 W Opening unit Supply voltage 24 V Operating conditions Temperature 0 to 50 °C Humidity 15% to 90% Accessoiries Adjustment / Dismantling Sink cabinet assembly of sides Sink cabinet assembly of base Back panel assembly non-condensing Technical information Power supply unit Head assembly Slide systems Upright timber cross-bar DWD-Dynamic-XP 71 30.04.2009 10:36 Uhr Seite 72 F147100527000 – 05|2009 – 5.000 (ENG) – GRASS Advertising Subject to changes, no liability for printing errors excepted. Sensomatic_ENG:Layout 1 Grass GmbH Movement-Systems Grass Platz 1 A 6973 Höchst, Austria Phone +43 (0) 5578 701-0 Fax +43 (0) 5578 701-59 E-Mail info@grass.eu