GAZBETON

Transcription

GAZBETON
GAZBETON
AAC
www.nuhyapi.com.tr
History of Nuh Group
1959 - Nuh Ticaret ve Sanayi A.Ş.
1966 - Nuh Çimento Sanayi A.Ş.
1976 - Nuh Gıda Dağıtım ve Pazarlama A.Ş.
1977 - Çimpaş Çimento ve İnşaat Malzemeleri Pazarlama A.Ş.
1979 - Nuh Makina Sanayi ve Ticaret A.Ş.
1979 - Çim-Nak Taşımacılık Ltd. Şti.
1995 - Nuh Beton A.Ş.
1995 - Nuh Yapı Ürünleri ve Makina Sanayi A.Ş.
1997 - Nuh Gayrimenkul İnşaat A.Ş.
1997 - Navig Trade
1998 - Nuh Enerji Tm
AAC
History of Nuh Yapı Ürünleri ve
Makine Sanayi A.Ş.
Established november 24, 1995, Nuh Yapı
Ürünleri ve Makine Sanayi A.Ş. was handed over
manufacturing facilities from Nuh Çimento
San.A.Ş. in May 14, 1998.
Nowadays activities are ;
- Lime
- AAC
- AAC Mortar
- Machinery Factory
EKO-BLOK
AAC in general is produced in different density classes. Today, most
of the AAC production throughout the world is mainly constituted
of 400 kg/m3 density blocks. Nuh Gazbeton is only one of the few
producers of 350 kg/m3 density class in the world.
PHYSICAL PROPERTIES
AAC CLASS
AVERAGE COMPRESSIVE
STRENGTH
UNIT WEIGHT
(Kg/m3)
350
G2/350
THERMAL CONDUCTIVITY VALUE
λh (W/mK)
(Kg/cm2)
EN 1745
TS 825
25
0,09
0,11
AAC DENSITY CLASSES ACCORDING TO DIN 4165 STANDARDS
DENSITY CLASSES
DRY DENSITIES
(Kg/m3)
300
350
400
450
500
550
600
> 250 - ≤ 300 > 300 - ≤ 350 > 350 - ≤ 400 >400 - ≤ 450 > 450 - ≤ 500 > 500 - ≤ 550 > 550 - ≤ 600
Advantages of eko-blok;
√
√
√
√
√
√
Lowest thermal conductivity values
Less wall thicknesses
Less dead-loads
Larger building spaces
Saves money during transportation
Less wall costs.
AAC
AAC
Nuh Group is the warranty of quality and experience of the Turkey construction sector. The latest production of Nuh Yapi is the AAC at standards
of EN 771-4. AAC is a porous wall material which is a basic mixture of
silica aggregate, lime and cement as well as aluminium powder to
provide porous substance. The mixture is horizontaly and verticaly cut
through by wires and the cake is hardened by steam cure.
AAC TECHNICAL VALUES
CLASS
COMPRESSIVE STRENGTH
(N/mm2)
DRY DENSITY
(Kg/m3)
SHRINKAGE
(mm/m)
POROSITY
%
THERMAL CONDUCTIVITY
λ ( W/mK)
G2 0.35
G2 0.4
G2 0.5
G4 0.6
2.5
2.5
2.5
5.0
350
400
500
600
0.1 – 0.2
0.1 – 0.2
0.1 – 0.2
0.1 – 0.2
86
84
80
76
0.09
0.11
0.13
0.16
AAC PRODUCT PROPERTIES
CLASS
Dry Unit
Weight
(Kg/m3)
Unit Weight in
Storage*
(Kg/m3)
Average
Compressive
Strength
Thermal
Conductivity Value
Thermal
Conductivity Value
Shrinkage
(mm/m)
Average Modulus of
Elasticity
(Kg/cm2 / N/ mm2)
(W/mK) EN 1745
(W/mK) TS 825
(Kg/cm2 )
G2/350
350
490
25 / 2,5
0,09
0,11
ort. 0,10
11,000
G2/400
400
560
25 / 2,5
0,11
0,13
ort. 0,10
12,500
G4/600
600
840
50 / 5,0
0,16
0,19
ort. .0,10
22,000
* Weight can be decrease in the storage according to waiting period
CERTIFICATE OF QUALITY
CERTIFICATE OF QUALITY
SIZE
PB2 / 0.60 AAC*
PB2 / 0.40 AAC*
PB2 / 0.35 AAC*
(mm)
DRY DENSITY
(Kg/dm3)
COMPRESSIVE
STRENGTH
(N/mm2)
SHRINKAGE
(mm/m)
DIMENSIONAL
ACCURACY
(mm)
600 x 250 x 75
600 x 250 x 100
600 x 250 x 125
600 x 250 x 150
600 x 250 x 175
0,30 - 0,35
Min. 2,5
Max. 0,2
± 1 - 1,5
0,35 - 0,40
Min. 2,5
Max. 0,2
± 1 - 1,5
0,55 - 0,60
Min. 5,0
Max. 0,2
± 1 - 1,5
600 x 250 x 200
600 x 250 x 250
600 x 250 x 300
600 x 250 x 75
600 x 250 x 100
600 x 250 x 125
600 x 250 x 150
600 x 250 x 175
600 x 250 x 200
600 x 250 x 250
600 x 250 x 300
600 x 250 x 75
600 x 250 x 100
600 x 250 x 125
600 x 250 x 150
600 x 250 x 175
600 x 250 x 200
600 x 250 x 250
600 x 250 x 300
* Tests are being performed according to (EN771-4, EN772-1, EN 772-13, EN772-16. EN680)
AAC PRODUCT TYPES
PRECISION BLOCKS
Thickness
PRODUCT DIMENSIONS (mm)
75
100
125
150
175
Height
250
Length
600
PROFILE WALL BLOCKS
300
PRODUCT DIMENSIONS (mm)
150
200
250
Height
250
Length
600
Product Class
250
G2/350 - G2/400 - G4/600
Product Class
Thickness
200
G2/350 - G2/400 - G4/600
300
AAC PRODUCT TYPES
INFILL BLOCKS
PRODUCT DIMENSIONS (mm)
Thickness
250
Height
400
Length
600
G2/350 - G2/400
Product Class
INSULATION PLATES
Thickness
PRODUCT DIMENSIONS (mm)
75
100
Height
250
Length
600
Product Class
G2/350 - G2/400
AAC PRODUCT TYPES
Lintel Dimensions
LINTEL
(mm)
100
Thickness
150
200
250
Length
1000-1200-1500-20003000
G3/500
SUPPORT DISTANCE OF
LINTELS
Openings
(mm)
Min.support
distance (mm)
Lintels Length
800
200
1200
1000
200
1500
1100
200
1500
1500
225
2000
2000
300
3000
2300
350
3000
Safety
Coefficient
35
Min. 2
250
Height
Product Class
Average compressive
strength
(Kg/cm2)
(mm)
* According to earthquake regulations each of the support distance of
the window and door lintels does not less than 15% of the openings
and not less than 200 mm
AAC GLUE MORTAR
THIN LAYER (T) READY MASONARY MORTAR
Compressive Strength
Category M 5
Initial Shear Strength
0,30 N/mm2
Chloride Contents
max. 0,01 Cl %
Class A1
Reaction to Fire
Water Absorption
2 kg/m2 0.5 minute
μ 5/20
Water Vapour Permeability
Thermal Conductivity
0,54 W / mK λ10 dry
AAC Glue Mortar is produced according to TS EN 998-2.
AAC Glue Mortar is come out to the market in 25 kg bag.
CONSUMPTION QUANTITIES FOR
AAC GLUE MORTAR
Wall Thicknesses (mm)
Glue Mortar Quantity (Kg/m2)
100
1,50
125
1,88
150
2,25
175
2,63
200
3,00
250
3,75
300
4,50
1783-CPD-0029
COMPARISON OF U VALUES
U values (W/m2K) for AAC external walls at 350 kg/m3
density within TS 825 (7.3.2)
Product Dimensions
STANDARD
U
7,5
10,0
12,5
15,0
17,5
20,0
22,5
25,0
27,5
30,0
32,5
35,0
37,5
40,0
REGION 1
0,7
1,17
0,93
0,77
0,65
0,57
0,50
0,45
0,41
0,37
0,35
0,32
0,30
0,28
0,26
REGION 2
0,6
1,17
0,93
0,77
0,65
0,57
0,50
0,45
0,41
0,37
0,35
0,32
0,30
0,28
0,26
REGION 3
0,5
1,17
0,93
0,77
0,65
0,57
0,50
0,45
0,41
0,37
0,35
0,32
0,30
0,28
0,26
REGION 4
0,4
1,17
0,93
0,77
0,65
0,57
0,50
0,45
0,41
0,37
0,35
0,32
0,30
0,28
0,26
U values (W/m2K) for AAC external walls at 400 kg/m3
density within TS 825 (7.3.2)
Product Dimensions
STANDARD
U
7,5
10,0
12,5
15,0
REGION 1
0,7
1,34
1,06
0,88
0,76
REGION 2
0,6
1,34
1,06
0,88
REGION 3
0,5
1,34
1,06
REGION 4
0,4
1,34
1,06
17,5
20,0
22,5
25,0
27,5
30,0
32,5
35,0
37,5
40,0
0,66
0,59
0,53
0,48
0,44
0,40
0,37
0,35
0,33
0,31
0,76
0,66
0,59
0,53
0,48
0,44
0,40
0,37
0,35
0,33
0,31
0,88
0,76
0,66
0,59
0,53
0,48
0,44
0,40
0,37
0,35
0,33
0,31
0,88
0,76
0,66
0,59
0,53
0,48
0,44
0,40
0,37
0,35
0,33
0,31
Duvar Kalınlıkları
U values (W/m2K) for AB class bricks external wall at
550 kg/m3 density within TS 825 (7.1.3.2)
STANDARD
Product Dimensions
U
11,5
14,5
19,0
24,0
REGION 1
0,7
1,68
1,41
1,14
0,94
REGION 2
0,6
1,68
1,41
1,14
0,94
REGION 3
0,5
1,68
1,41
1,14
0,94
REGION 4
0,4
1,68
1,41
1,14
0,94
* Grey cells not comply the standards
COMPARISON OF U VALUES
U values (W/m2K) for W class bricks external wall at
550 kg/m3 density within TS 825 (7.1.4.2)
Product Dimensions
STANDARD
U
11,5
14,5
17,5
19,0
24,0
30,0
REGION 1
0,7
1,29
1,07
0,92
0,85
0,70
0,57
REGION 2
0,6
1,29
1,07
0,92
0,85
0,70
0,57
REGION 3
0,5
1,29
1,07
0,92
0,85
0,70
0,57
REGION 4
0,4
1,29
1,07
0,92
0,85
0,70
0,57
U values (W/m2K) for DDB type class bims concrete external wall at
450 kg/m3 density within TS 825 (7.4.3)
Product Dimensions
STANDARD
U
9,0
10,0
15,0
19,0
25,0
REGION 1
0,7
1,78
1,65
1,22
1,00
1,00
REGION 2
0,6
1,78
1,65
1,22
1,00
1,00
REGION 3
0,5
1,78
1,65
1,22
1,00
1,00
REGION 4
0,4
1,78
1,65
1,22
1,00
1,00
* Grey cells not comply the standards
COMPARISON OF U VALUES
(W/m2K) VALUES OF DIFFERENT MATERIALS THROUGH
CLIMATE REGIONS
1,90
1,80
1,70
1,60
1,50
1,40
1,20
1,10
1,00
0,90
0,80
OLD REGION LIMIT 1
0,70
REGION LIMIT 1
REGION LIMIT 2
0,60
REGION LIMIT 3
0,50
REGION LIMIT 4
0,40
0,30
0,20
10,0
11,5
14,5
15,0
17,5
19,0
20,0
24,0
25,0
27,5
THICKNESSES OF THE MATERIALS
COMPARISON OF DIFFERENT WALL MATERIALS IN DENSITY AND THERMAL
CONDUCTIVITY VALUES
0,30
0,25
0,20
0,15
0,10
0,05
0,00
550
550
350
400
7.3.2
AAC
7.3.2
AAC
DENSITIES ( kg/m3)
450
450
32,5
35,0
37,5
AAC 400
AAC 350
AAC 400
AAC 350
AAC 400
AAC 350
AAC 400
AAC 350
AAC 400
30,0
BRICK W
AAC 350
AAC 400
AAC 350
BIMS
AAC 400
AAC 350
BRICK W
AAC 400
22,5
BRICK AB
AAC 350
AAC 400
BIMS
AAC 350
BRICK W
BRICK AB
AAC 400
BRICK W
AAC 350
BIMS
AAC 400
AAC 350
BRICK W
AAC 400
12,5
BRICK AB
AAC 350
BRICK W
BIMS
BRICK AB
AAC 400
BIMS
9,0
THERMAL CONDUCTIVITY VALUES (W/mK)
7,5
AAC 350
0,00
AAC 400
0,10
AAC 350
LIMIT VALUES OF THE REGIONS (W/m2K)
1,30
40,0
AAC WALL THICKNESSES THROUGH THE CLIMATE REGIONS (EXTERNAL WALLS)
U WALL
(W/m2K)
REGION 1
0,70
REGION 2
0,60
REGION 3
0,50
REGION 4
0,40
A study conducted by İstanbul Technical
University shows the minimum required wall
thicknesses of eko-blok and G2/400 AAC
blocks through the four climate regions
described in TS825.
AAC WALL THICKNESSES THROUGH THE
CLIMATE REGIONS (EXTERNAL WALLS)
REGION 1
REGION 2
REGION 3
REGION 4
eko-blok
15,0
17,5
20,0
27,5
G2/400
17,5
20,0
25,0
32,5
REGION 1
REGION 2
REGION 3
REGION 4
СОПРОТИВЛЕНИЕ
THERMAL RESISTANCE
ТЕПЛОПЕРЕДАЧИ
R Value
MATERIAL
G2/350*
G2/400**
DRY DENSITY
(Kg/m3)
THERMAL CONDUCTIVITY
350
400
(W/mK)
0,11
0,13
THICKNESSES
(mm)
THERMAL RESISTANCE
VALUES (W/m²K)*
100
1,11
125
1,34
150
1,57
175
1,79
200
2,02
250
2,47
300
2,93
100
0,97
125
1,16
150
1,36
175
1,55
200
1,74
250
2,13
300
2,51
* Thermal Resistance Value (R) For 350 kg/m3 Density
** Thermal Resistance Value (R) For 400 kg/m3 Density
It is accepted as inner walls 10
mm gypsum plaster and external
walls 20 mm cement based
plaster in the calculations.
FIRE RESISTANCE VALUES
REGULATIONS OF PROTECTING BUILDINGS FROM FIRE
CONSTRUCTION MATERIALS
BUILDING FLOORS (NUMBER OF FLOORS)
≥2
≥3–5
>5
HIGH RISE BUILDING
LOADING AND RIGID
WALLS-SUPPORT-COLUMN
F30 - B
F90 - A
F90 - A
F90 -A (< h : 60 m )
F120-A (> h :60 m )
NON LOADING EXTERNAL WALLS
Min. B2
A or F30 - B
A or F30 - B
A or F90 - AB
FLATS AND SEPERATING WALLS BETWEEN
SPECIAL ROOMS
F90 - A
F90 - A
F90 - A
F90 - A
FIRE WALLS AND SPECIAL BOUNDARY
WALLS
F30 - A
F90 - A
F90 - A
F90 - A ( < h :60 m )
Nuh AAC is A1 class and non-combustible wall material.
AAC FIRE RESISTANCE
MIN. WALL THICKNESSES ACCORDING TO FIRE CLASSES (mm)*
FIRE RESISTANCE CLASSES
NON LOADING WALLS
(WITHOUT PLASTER)
NON LOADING WALLS
(BOTH SIDE WITH PLASTER)
F30
F60
F90
F120
F180
75
75
100
115
150
50
75
75
75
115
* Defined values are in DIN 4102– 4.
Resistance Periods to the Fire of the Materials
Fire Class
Resistance Periods
(minute)
F- 30
30 - 59
F- 60
60 - 89
F- 90
90 - 119
F- 120
120 - 179
F- 180
180 <
Loading walls and Columns in the buildings which are more than two
floors should be constructed as F90-A class in terms of Fire safety
Fire walls of interior walls and adjoining buildings are should be
designed minimum 90 minute resistance to the fire.
SOUND INSULATION
SOUND RESISTANCE VALUES OF NUH AAC WALL BLOCKS
ACCORDING TO DIFFERENT DENSITIES*
CLASS
G2
G2
G4
DENSITY
(Kg/m3)
350
400
600
* Walls are estimated as without plaster.
THICKNESSES
WEIGHT
R VALUES
10
35
31
15
52
36
20
70
39
25
87
42
30
105
44
10
40
32
15
60
37
20
80
41
25
100
43
30
120
46
10
60
37
15
90
42
20
120
46
25
150
48
30
180
50
(cm)
(Kg/m2)
(dB)
PALLET DIMENSIONS
PALLET TABLE
HEIGHT (cm)
HEIGHT INC.
PALLET (cm)
PALLET WEIGHT
14,40
120
132
572
1,080
10,80
120
132
572
60
1,125
9,00
125
137
595
15
48
1,080
7,20
120
132
572
17,5
42
1,103
6,30
122,5
135
583
20
36
1,080
5,40
120
132
572
25
30
1,125
4,50
125
137
595
30
24
1,080
3,60
120
132
572
BLOCK DIMENSIONS
PCS
M³
M²
7,5
96
1,080
10
72
12,5
(cm)
60
WIDTH
(cm)
75
25
Standard pallet dimensions 120 cm x 75 cm
* Class G2/400
LENGTH
(cm)
( kg)
120
AAC
www.cizgeadam.com.tr
Akyar Mevkii PK. 7 41800
Hereke - KOCAELİ - TÜRKİYE
Tel. +90 262 511 55 20 / 10 hat (pbx)
Fax. +90 262 511 51 82
E-Mail. nuhyapi@nuhyapi.com.tr
1 10 109 -ENG
w w w.nuhyapi.com.tr
1783-CPD-0030