GAZBETON
Transcription
GAZBETON
GAZBETON AAC www.nuhyapi.com.tr History of Nuh Group 1959 - Nuh Ticaret ve Sanayi A.Ş. 1966 - Nuh Çimento Sanayi A.Ş. 1976 - Nuh Gıda Dağıtım ve Pazarlama A.Ş. 1977 - Çimpaş Çimento ve İnşaat Malzemeleri Pazarlama A.Ş. 1979 - Nuh Makina Sanayi ve Ticaret A.Ş. 1979 - Çim-Nak Taşımacılık Ltd. Şti. 1995 - Nuh Beton A.Ş. 1995 - Nuh Yapı Ürünleri ve Makina Sanayi A.Ş. 1997 - Nuh Gayrimenkul İnşaat A.Ş. 1997 - Navig Trade 1998 - Nuh Enerji Tm AAC History of Nuh Yapı Ürünleri ve Makine Sanayi A.Ş. Established november 24, 1995, Nuh Yapı Ürünleri ve Makine Sanayi A.Ş. was handed over manufacturing facilities from Nuh Çimento San.A.Ş. in May 14, 1998. Nowadays activities are ; - Lime - AAC - AAC Mortar - Machinery Factory EKO-BLOK AAC in general is produced in different density classes. Today, most of the AAC production throughout the world is mainly constituted of 400 kg/m3 density blocks. Nuh Gazbeton is only one of the few producers of 350 kg/m3 density class in the world. PHYSICAL PROPERTIES AAC CLASS AVERAGE COMPRESSIVE STRENGTH UNIT WEIGHT (Kg/m3) 350 G2/350 THERMAL CONDUCTIVITY VALUE λh (W/mK) (Kg/cm2) EN 1745 TS 825 25 0,09 0,11 AAC DENSITY CLASSES ACCORDING TO DIN 4165 STANDARDS DENSITY CLASSES DRY DENSITIES (Kg/m3) 300 350 400 450 500 550 600 > 250 - ≤ 300 > 300 - ≤ 350 > 350 - ≤ 400 >400 - ≤ 450 > 450 - ≤ 500 > 500 - ≤ 550 > 550 - ≤ 600 Advantages of eko-blok; √ √ √ √ √ √ Lowest thermal conductivity values Less wall thicknesses Less dead-loads Larger building spaces Saves money during transportation Less wall costs. AAC AAC Nuh Group is the warranty of quality and experience of the Turkey construction sector. The latest production of Nuh Yapi is the AAC at standards of EN 771-4. AAC is a porous wall material which is a basic mixture of silica aggregate, lime and cement as well as aluminium powder to provide porous substance. The mixture is horizontaly and verticaly cut through by wires and the cake is hardened by steam cure. AAC TECHNICAL VALUES CLASS COMPRESSIVE STRENGTH (N/mm2) DRY DENSITY (Kg/m3) SHRINKAGE (mm/m) POROSITY % THERMAL CONDUCTIVITY λ ( W/mK) G2 0.35 G2 0.4 G2 0.5 G4 0.6 2.5 2.5 2.5 5.0 350 400 500 600 0.1 – 0.2 0.1 – 0.2 0.1 – 0.2 0.1 – 0.2 86 84 80 76 0.09 0.11 0.13 0.16 AAC PRODUCT PROPERTIES CLASS Dry Unit Weight (Kg/m3) Unit Weight in Storage* (Kg/m3) Average Compressive Strength Thermal Conductivity Value Thermal Conductivity Value Shrinkage (mm/m) Average Modulus of Elasticity (Kg/cm2 / N/ mm2) (W/mK) EN 1745 (W/mK) TS 825 (Kg/cm2 ) G2/350 350 490 25 / 2,5 0,09 0,11 ort. 0,10 11,000 G2/400 400 560 25 / 2,5 0,11 0,13 ort. 0,10 12,500 G4/600 600 840 50 / 5,0 0,16 0,19 ort. .0,10 22,000 * Weight can be decrease in the storage according to waiting period CERTIFICATE OF QUALITY CERTIFICATE OF QUALITY SIZE PB2 / 0.60 AAC* PB2 / 0.40 AAC* PB2 / 0.35 AAC* (mm) DRY DENSITY (Kg/dm3) COMPRESSIVE STRENGTH (N/mm2) SHRINKAGE (mm/m) DIMENSIONAL ACCURACY (mm) 600 x 250 x 75 600 x 250 x 100 600 x 250 x 125 600 x 250 x 150 600 x 250 x 175 0,30 - 0,35 Min. 2,5 Max. 0,2 ± 1 - 1,5 0,35 - 0,40 Min. 2,5 Max. 0,2 ± 1 - 1,5 0,55 - 0,60 Min. 5,0 Max. 0,2 ± 1 - 1,5 600 x 250 x 200 600 x 250 x 250 600 x 250 x 300 600 x 250 x 75 600 x 250 x 100 600 x 250 x 125 600 x 250 x 150 600 x 250 x 175 600 x 250 x 200 600 x 250 x 250 600 x 250 x 300 600 x 250 x 75 600 x 250 x 100 600 x 250 x 125 600 x 250 x 150 600 x 250 x 175 600 x 250 x 200 600 x 250 x 250 600 x 250 x 300 * Tests are being performed according to (EN771-4, EN772-1, EN 772-13, EN772-16. EN680) AAC PRODUCT TYPES PRECISION BLOCKS Thickness PRODUCT DIMENSIONS (mm) 75 100 125 150 175 Height 250 Length 600 PROFILE WALL BLOCKS 300 PRODUCT DIMENSIONS (mm) 150 200 250 Height 250 Length 600 Product Class 250 G2/350 - G2/400 - G4/600 Product Class Thickness 200 G2/350 - G2/400 - G4/600 300 AAC PRODUCT TYPES INFILL BLOCKS PRODUCT DIMENSIONS (mm) Thickness 250 Height 400 Length 600 G2/350 - G2/400 Product Class INSULATION PLATES Thickness PRODUCT DIMENSIONS (mm) 75 100 Height 250 Length 600 Product Class G2/350 - G2/400 AAC PRODUCT TYPES Lintel Dimensions LINTEL (mm) 100 Thickness 150 200 250 Length 1000-1200-1500-20003000 G3/500 SUPPORT DISTANCE OF LINTELS Openings (mm) Min.support distance (mm) Lintels Length 800 200 1200 1000 200 1500 1100 200 1500 1500 225 2000 2000 300 3000 2300 350 3000 Safety Coefficient 35 Min. 2 250 Height Product Class Average compressive strength (Kg/cm2) (mm) * According to earthquake regulations each of the support distance of the window and door lintels does not less than 15% of the openings and not less than 200 mm AAC GLUE MORTAR THIN LAYER (T) READY MASONARY MORTAR Compressive Strength Category M 5 Initial Shear Strength 0,30 N/mm2 Chloride Contents max. 0,01 Cl % Class A1 Reaction to Fire Water Absorption 2 kg/m2 0.5 minute μ 5/20 Water Vapour Permeability Thermal Conductivity 0,54 W / mK λ10 dry AAC Glue Mortar is produced according to TS EN 998-2. AAC Glue Mortar is come out to the market in 25 kg bag. CONSUMPTION QUANTITIES FOR AAC GLUE MORTAR Wall Thicknesses (mm) Glue Mortar Quantity (Kg/m2) 100 1,50 125 1,88 150 2,25 175 2,63 200 3,00 250 3,75 300 4,50 1783-CPD-0029 COMPARISON OF U VALUES U values (W/m2K) for AAC external walls at 350 kg/m3 density within TS 825 (7.3.2) Product Dimensions STANDARD U 7,5 10,0 12,5 15,0 17,5 20,0 22,5 25,0 27,5 30,0 32,5 35,0 37,5 40,0 REGION 1 0,7 1,17 0,93 0,77 0,65 0,57 0,50 0,45 0,41 0,37 0,35 0,32 0,30 0,28 0,26 REGION 2 0,6 1,17 0,93 0,77 0,65 0,57 0,50 0,45 0,41 0,37 0,35 0,32 0,30 0,28 0,26 REGION 3 0,5 1,17 0,93 0,77 0,65 0,57 0,50 0,45 0,41 0,37 0,35 0,32 0,30 0,28 0,26 REGION 4 0,4 1,17 0,93 0,77 0,65 0,57 0,50 0,45 0,41 0,37 0,35 0,32 0,30 0,28 0,26 U values (W/m2K) for AAC external walls at 400 kg/m3 density within TS 825 (7.3.2) Product Dimensions STANDARD U 7,5 10,0 12,5 15,0 REGION 1 0,7 1,34 1,06 0,88 0,76 REGION 2 0,6 1,34 1,06 0,88 REGION 3 0,5 1,34 1,06 REGION 4 0,4 1,34 1,06 17,5 20,0 22,5 25,0 27,5 30,0 32,5 35,0 37,5 40,0 0,66 0,59 0,53 0,48 0,44 0,40 0,37 0,35 0,33 0,31 0,76 0,66 0,59 0,53 0,48 0,44 0,40 0,37 0,35 0,33 0,31 0,88 0,76 0,66 0,59 0,53 0,48 0,44 0,40 0,37 0,35 0,33 0,31 0,88 0,76 0,66 0,59 0,53 0,48 0,44 0,40 0,37 0,35 0,33 0,31 Duvar Kalınlıkları U values (W/m2K) for AB class bricks external wall at 550 kg/m3 density within TS 825 (7.1.3.2) STANDARD Product Dimensions U 11,5 14,5 19,0 24,0 REGION 1 0,7 1,68 1,41 1,14 0,94 REGION 2 0,6 1,68 1,41 1,14 0,94 REGION 3 0,5 1,68 1,41 1,14 0,94 REGION 4 0,4 1,68 1,41 1,14 0,94 * Grey cells not comply the standards COMPARISON OF U VALUES U values (W/m2K) for W class bricks external wall at 550 kg/m3 density within TS 825 (7.1.4.2) Product Dimensions STANDARD U 11,5 14,5 17,5 19,0 24,0 30,0 REGION 1 0,7 1,29 1,07 0,92 0,85 0,70 0,57 REGION 2 0,6 1,29 1,07 0,92 0,85 0,70 0,57 REGION 3 0,5 1,29 1,07 0,92 0,85 0,70 0,57 REGION 4 0,4 1,29 1,07 0,92 0,85 0,70 0,57 U values (W/m2K) for DDB type class bims concrete external wall at 450 kg/m3 density within TS 825 (7.4.3) Product Dimensions STANDARD U 9,0 10,0 15,0 19,0 25,0 REGION 1 0,7 1,78 1,65 1,22 1,00 1,00 REGION 2 0,6 1,78 1,65 1,22 1,00 1,00 REGION 3 0,5 1,78 1,65 1,22 1,00 1,00 REGION 4 0,4 1,78 1,65 1,22 1,00 1,00 * Grey cells not comply the standards COMPARISON OF U VALUES (W/m2K) VALUES OF DIFFERENT MATERIALS THROUGH CLIMATE REGIONS 1,90 1,80 1,70 1,60 1,50 1,40 1,20 1,10 1,00 0,90 0,80 OLD REGION LIMIT 1 0,70 REGION LIMIT 1 REGION LIMIT 2 0,60 REGION LIMIT 3 0,50 REGION LIMIT 4 0,40 0,30 0,20 10,0 11,5 14,5 15,0 17,5 19,0 20,0 24,0 25,0 27,5 THICKNESSES OF THE MATERIALS COMPARISON OF DIFFERENT WALL MATERIALS IN DENSITY AND THERMAL CONDUCTIVITY VALUES 0,30 0,25 0,20 0,15 0,10 0,05 0,00 550 550 350 400 7.3.2 AAC 7.3.2 AAC DENSITIES ( kg/m3) 450 450 32,5 35,0 37,5 AAC 400 AAC 350 AAC 400 AAC 350 AAC 400 AAC 350 AAC 400 AAC 350 AAC 400 30,0 BRICK W AAC 350 AAC 400 AAC 350 BIMS AAC 400 AAC 350 BRICK W AAC 400 22,5 BRICK AB AAC 350 AAC 400 BIMS AAC 350 BRICK W BRICK AB AAC 400 BRICK W AAC 350 BIMS AAC 400 AAC 350 BRICK W AAC 400 12,5 BRICK AB AAC 350 BRICK W BIMS BRICK AB AAC 400 BIMS 9,0 THERMAL CONDUCTIVITY VALUES (W/mK) 7,5 AAC 350 0,00 AAC 400 0,10 AAC 350 LIMIT VALUES OF THE REGIONS (W/m2K) 1,30 40,0 AAC WALL THICKNESSES THROUGH THE CLIMATE REGIONS (EXTERNAL WALLS) U WALL (W/m2K) REGION 1 0,70 REGION 2 0,60 REGION 3 0,50 REGION 4 0,40 A study conducted by İstanbul Technical University shows the minimum required wall thicknesses of eko-blok and G2/400 AAC blocks through the four climate regions described in TS825. AAC WALL THICKNESSES THROUGH THE CLIMATE REGIONS (EXTERNAL WALLS) REGION 1 REGION 2 REGION 3 REGION 4 eko-blok 15,0 17,5 20,0 27,5 G2/400 17,5 20,0 25,0 32,5 REGION 1 REGION 2 REGION 3 REGION 4 СОПРОТИВЛЕНИЕ THERMAL RESISTANCE ТЕПЛОПЕРЕДАЧИ R Value MATERIAL G2/350* G2/400** DRY DENSITY (Kg/m3) THERMAL CONDUCTIVITY 350 400 (W/mK) 0,11 0,13 THICKNESSES (mm) THERMAL RESISTANCE VALUES (W/m²K)* 100 1,11 125 1,34 150 1,57 175 1,79 200 2,02 250 2,47 300 2,93 100 0,97 125 1,16 150 1,36 175 1,55 200 1,74 250 2,13 300 2,51 * Thermal Resistance Value (R) For 350 kg/m3 Density ** Thermal Resistance Value (R) For 400 kg/m3 Density It is accepted as inner walls 10 mm gypsum plaster and external walls 20 mm cement based plaster in the calculations. FIRE RESISTANCE VALUES REGULATIONS OF PROTECTING BUILDINGS FROM FIRE CONSTRUCTION MATERIALS BUILDING FLOORS (NUMBER OF FLOORS) ≥2 ≥3–5 >5 HIGH RISE BUILDING LOADING AND RIGID WALLS-SUPPORT-COLUMN F30 - B F90 - A F90 - A F90 -A (< h : 60 m ) F120-A (> h :60 m ) NON LOADING EXTERNAL WALLS Min. B2 A or F30 - B A or F30 - B A or F90 - AB FLATS AND SEPERATING WALLS BETWEEN SPECIAL ROOMS F90 - A F90 - A F90 - A F90 - A FIRE WALLS AND SPECIAL BOUNDARY WALLS F30 - A F90 - A F90 - A F90 - A ( < h :60 m ) Nuh AAC is A1 class and non-combustible wall material. AAC FIRE RESISTANCE MIN. WALL THICKNESSES ACCORDING TO FIRE CLASSES (mm)* FIRE RESISTANCE CLASSES NON LOADING WALLS (WITHOUT PLASTER) NON LOADING WALLS (BOTH SIDE WITH PLASTER) F30 F60 F90 F120 F180 75 75 100 115 150 50 75 75 75 115 * Defined values are in DIN 4102– 4. Resistance Periods to the Fire of the Materials Fire Class Resistance Periods (minute) F- 30 30 - 59 F- 60 60 - 89 F- 90 90 - 119 F- 120 120 - 179 F- 180 180 < Loading walls and Columns in the buildings which are more than two floors should be constructed as F90-A class in terms of Fire safety Fire walls of interior walls and adjoining buildings are should be designed minimum 90 minute resistance to the fire. SOUND INSULATION SOUND RESISTANCE VALUES OF NUH AAC WALL BLOCKS ACCORDING TO DIFFERENT DENSITIES* CLASS G2 G2 G4 DENSITY (Kg/m3) 350 400 600 * Walls are estimated as without plaster. THICKNESSES WEIGHT R VALUES 10 35 31 15 52 36 20 70 39 25 87 42 30 105 44 10 40 32 15 60 37 20 80 41 25 100 43 30 120 46 10 60 37 15 90 42 20 120 46 25 150 48 30 180 50 (cm) (Kg/m2) (dB) PALLET DIMENSIONS PALLET TABLE HEIGHT (cm) HEIGHT INC. PALLET (cm) PALLET WEIGHT 14,40 120 132 572 1,080 10,80 120 132 572 60 1,125 9,00 125 137 595 15 48 1,080 7,20 120 132 572 17,5 42 1,103 6,30 122,5 135 583 20 36 1,080 5,40 120 132 572 25 30 1,125 4,50 125 137 595 30 24 1,080 3,60 120 132 572 BLOCK DIMENSIONS PCS M³ M² 7,5 96 1,080 10 72 12,5 (cm) 60 WIDTH (cm) 75 25 Standard pallet dimensions 120 cm x 75 cm * Class G2/400 LENGTH (cm) ( kg) 120 AAC www.cizgeadam.com.tr Akyar Mevkii PK. 7 41800 Hereke - KOCAELİ - TÜRKİYE Tel. +90 262 511 55 20 / 10 hat (pbx) Fax. +90 262 511 51 82 E-Mail. nuhyapi@nuhyapi.com.tr 1 10 109 -ENG w w w.nuhyapi.com.tr 1783-CPD-0030