Catalyst 6500 Series DFC Memory Installation Note
Transcription
Catalyst 6500 Series DFC Memory Installation Note
Catalyst 6500 Series DFC Memory Installation Note Product numbers: MEM-DFC-128M=, MEM-DFC-256M=, MEM-DFC-512M= (for WS-F6K-DFC) MEM-XCEF720-512M= (for WS-F6K-DFC3A, WS-F6700-DFC3A, WS-F6700-DFC3B) MEM-XCEF720-1GB= (for WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL) This publication provides procedures for installing memory on the following Catalyst 6500 series Distributed Forwarding Cards (DFCs): • WS-F6K-DFC • WS-F6K-DFC3A • WS-F6700-DFC3A • WS-F6700-DFC3B • WS-F6700-DFC3BXL Note For the WS-F6700-DFC3A, WS-F6700-DFC3B, and WS-F6700-DFC3BXL, the memory module is located on the base WS-X67xx module, under the DFC3 daughtercard. You must remove the daughtercard from the module to upgrade the memory. Corporate Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA Copyright © 2001–2004 Cisco Systems, Inc. All rights reserved. Contents Contents This publication contains these sections: • Safety Overview, page 2 • Required Tools, page 3 • Installation Guidelines, page 3 • Verifying the DFC Memory, page 4 • Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only), page 5 • Removing the SODIMM, page 9 • Installing the SODIMM, page 13 • Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only), page 14 • Related Documentation, page 18 • Obtaining Documentation, page 19 • Documentation Feedback, page 19 • Obtaining Technical Assistance, page 20 • Obtaining Additional Publications and Information, page 21 Safety Overview Safety warnings appear throughout this publication in procedures that, if performed incorrectly, may harm you. A warning symbol precedes each warning statement. Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071 SAVE THESE INSTRUCTIONS Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030 Warning Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. Statement 1034 Catalyst 6500 Series DFC Memory Installation Note 2 78-12409-04 Required Tools Required Tools These tools are required to upgrade the memory on the Catalyst 6500 series DFC: Caution • 3/16-inch flat-blade screwdriver for the captive installation screws on the module on which the DFC is installed • WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL only—Number 1 Phillips-head screwdriver for the screws and cap nuts that fasten the DFC3 to the WS-X67xx module • Antistatic mat or antistatic foam • Your own ESD-prevention equipment or the disposable grounding wrist strap included with all upgrade kits, field-replaceable units (FRUs), and spares Always use an ESD wrist strap when handling modules or coming into contact with internal components. Installation Guidelines Observe the following cautions when upgrading the memory on a DFC: Caution Always use an ESD wrist strap when handling modules or coming into contact with internal components. Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the module. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Caution SODIMMs are sensitive components that are susceptible to ESD damage. To prevent ESD damage, handle SODIMMs by the edges only; avoid touching the memory modules, pins, or traces (the metal fingers along the connector edge of the SODIMM). Caution When inserting SODIMMs, use firm but not excessive pressure. If you damage a socket, you will have to return the DFC to the factory for repair. Caution Use care not to damage the connectors on the module. If you damage a connector, it will be necessary to return the module to Cisco for repair. Caution You must install screws in all available standoffs. The screws provide grounding between the DFC3 and the module. Failure to install all screws will invalidate the safety approvals and pose a risk of fire and electrical hazard. Catalyst 6500 Series DFC Memory Installation Note 78-12409-04 3 Verifying the DFC Memory Verifying the DFC Memory Table 1 lists the default memory configurations and available upgrades. Table 1 Memory Configurations DFC version Default Memory Upgradeable Memory Part Number WS-F6K-DFC3 128 MB 256 MB 512 MB MEM-DFC-256M= MEM-DFC-512M= WS-F6K-DFC3A 512 MB No upgrade available – WS-F6700-DFC3A 256 MB 512 MB 1 GB MEM-XCEF720-512M= MEM-XCEF720-1GB= WS-F6700-DFC3B 256 MB 512 MB 1 GB MEM-XCEF720-512M= MEM-XCEF720-1GB= WS-F6700-DFC3BXL 1 GB No upgrade available – To verify the memory configuration on the DFC, enter the remote command module mod show memory summary command, where mod is the module with an installed DFC. Add the processor and I/O totals to get the total memory for the DFC. This example shows how to check the total memory on the DFC on a fabric-enabled module in slot 9: Router# remote command module 9 show memory summary Router-dfc9# Processor I/O Head 31C5BFC0 E000000 Total(b) 205144128 33554440 Used(b) 127792712 5987288 Free(b) 77351416 27567152 Lowest(b) Largest(b) 65520524 64818696 27567152 27567100 ...<output truncated> Router# The above example shows the total memory on the DFC is 256 MB. Catalyst 6500 Series DFC Memory Installation Note 4 78-12409-04 Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only) Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only) For the WS-F6700-DFC3A, WS-F6700-DFC3B, and WS-F6700-DFC3BXL, the memory module is located on the base WS-X67xx module, under the DFC3. To upgrade the DFC3 memory, you must first remove the DFC3 from the module. To remove a DFC3, follow these steps: Warning Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. Statement 1034 Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the module. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Step 1 Remove the module from the Catalyst 6500 series switch. (Refer to the Catalyst 6500 Series Module Installation Guide for removal instructions.) Step 2 Place the module on an antistatic mat or foam, with the front of the module facing toward you. Step 3 Use a Phillips-head screwdriver to remove the securing screws and the two cap nuts. (See Figure 1.) Catalyst 6500 Series DFC Memory Installation Note 78-12409-04 5 Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only) Removing the Securing Screws and Cap Nuts WS-X5530 WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP STATUS 1 Step 4 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 99719 Figure 1 Partially install the cap nut, as shown in Figure 2, about 3 turns so that there is a space of about 1/8 inch (3.175 mm) between the bottom of the cap nut and the top of the DFC3. The cap nut acts as a stop when you unseat the connector so that the DFC3 does not move horizontally and cause damage to the module. Catalyst 6500 Series DFC Memory Installation Note 6 78-12409-04 Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only) Figure 2 Partially Installing the Cap Nut Cap nut 120047 Appx 1/8 inch Step 5 With your left hand, lift slightly at the location shown in Figure 3. While lifting with your left hand, rock the DFC3 up and down with your right hand, no more than half an inch in either direction, to unseat the DFC3 from the module. Catalyst 6500 Series DFC Memory Installation Note 78-12409-04 7 Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only) Figure 3 Unseat the DFC3 from the Module Lift here Rock up and down WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP STATUS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 120048 WS-X5530 Step 6 Remove the cap nut. Step 7 Hold the DFC3 with both hands, and gently lift the DFC3 straight up from the module. (See Figure 4.) Catalyst 6500 Series DFC Memory Installation Note 8 78-12409-04 Removing the SODIMM Removing the DFC3 from the Module WS-X5530 WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP STATUS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Step 8 Place the removed DFC3 on an antistatic mat or antistatic foam pad. Step 9 Proceed to the “Removing the SODIMM” section on page 9. 71 18 19 20 21 22 23 24 120049 Figure 4 Removing the SODIMM Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. To remove the existing SODIMM, follow these steps: Step 1 Make sure that you take the necessary precautions to prevent ESD damage. Step 2 Remove the module with the DFC or DFC3A from the system. (Refer to the Catalyst 6500 Series Module Installation Guide for removal instructions.) Step 3 Place the module on an antistatic mat or pad. Step 4 Locate the SODIMM. (See Figure 5 for the WS-F6K-DFC, see Figure 6 for the WS-F6K-DFC3A, and see Figure 7 for the WS-X6700-DFC3A.) Catalyst 6500 Series DFC Memory Installation Note 78-12409-04 9 Removing the SODIMM Figure 5 Location of SODIMM on a WS-F6K-DFC SDRAM SODIMM TUS STA 2 1 3 LINE 1 Figure 6 5 4 2 7 6 LINE 3 LINE 4 LINE 5 LINE 6 LINE 11 9 10 8 LINE 7 8 LINE 9 LINE 13 12 10 LINE 15 14 LINE 11 12 51542 WS-X5530 16 LINE 13 LINE 14 LINE 15 LINE 16 LINE Location of SODIMM on a WS-F6K-DFC3A S S 3 3 5 SS 5 0 3 5 0 3 5 0 WS-X5530 Catalyst 6500 Series DFC Memory Installation Note 10 78-12409-04 Removing the SODIMM Figure 7 Location of SODIMM on a WS-X67xx Module for the DFC3A, DFC3B, and DFC3BXL DDR SDRAM SODIMM WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP STATUS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 113340 WS-X5530 Catalyst 6500 Series DFC Memory Installation Note 78-12409-04 11 Removing the SODIMM Step 5 Release the spring clips from the SODIMM, and release the SODIMM from the socket. (See Figure 8.) Figure 8 Releasing the SODIMM Spring Clips Pull the tabs away with your thumbs, bracing your forefingers against the rails. The memory module will be released. Then raise the memory module to a vertical position. 51543 Memory module Step 6 Caution Step 7 When both ends of the SODIMM are released from the socket, grasp the ends of the SODIMM with your thumb and forefinger, and pull the SODIMM completely out of the socket. SODIMMs are sensitive components that are susceptible to ESD damage. To prevent ESD damage, handle SODIMMs by the edges only; avoid touching the memory modules, pins, or traces (the metal fingers along the connector edge of the SODIMM). (See Figure 9.) Place the SODIMM in an antistatic container to protect it from ESD damage. This completes the SODIMM removal procedure. Proceed to the “Installing the SODIMM” section on page 13 to install the new SODIMM. Catalyst 6500 Series DFC Memory Installation Note 12 78-12409-04 Installing the SODIMM Installing the SODIMM Caution SODIMMs are sensitive components that are susceptible to ESD damage. To prevent ESD damage, handle SODIMMs by the edges only; avoid touching the memory modules, pins, or traces (the metal fingers along the connector edge of the SODIMM). (See Figure 9.) Handling a SODIMM 51544 Figure 9 Follow these steps to install the new SODIMM: Step 1 Remove a new SODIMM from the antistatic container. Step 2 Hold the SODIMM with the component side up and with the connector edge (the metal fingers) away from you. Step 3 Hold the sides of the SODIMM between your thumbs and forefingers. (See Figure 9.) Step 4 Tilt the SODIMM to approximately the same angle as the socket, and insert the connector edge into the socket. Caution When inserting SODIMMs, use firm but not excessive pressure. If you damage a socket, you will have to return the DFC to the factory for repair. Step 5 Press the SODIMM down until it is secured by the spring clips. (See Figure 10.) Installing the SODIMM 28736 Figure 10 Catalyst 6500 Series DFC Memory Installation Note 78-12409-04 13 Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only) Step 6 When the SODIMM is installed, check the two alignment holes, and ensure that the spring retainer is visible. If it is not, the SODIMM is not seated properly. If any SODIMM appears misaligned, carefully remove it and reseat it in the socket. Push the SODIMM firmly back into the socket until the retainer springs snap into place. Step 7 If you upgraded the memory on the WS-F6700-DFC3A, WS-F6700-DFC3B, or WS-F6700-DFC3BXL, you need to reinstall the DFC3. Proceed to the “Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)” section on page 14 to install the DFC3. Otherwise, reinstall the module. (Refer to the Catalyst 6500 Series Module Installation Guide for removal instructions.) Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only) To install the DFC3 on a WS-X67xx module, follow these steps: Caution Step 1 During this procedure, wear grounding wrist straps to avoid ESD damage to the module. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Align the mounting holes on the DFC3 (see Figure 11) with the male standoffs on the module. (See Figure 12.) Make sure that the remaining mounting holes on the DFC3 are aligned with the remaining standoffs. Figure 11 Mounting Holes on the DFC3 99361 Align with the male standoffs on the module Catalyst 6500 Series DFC Memory Installation Note 14 78-12409-04 Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only) Figure 12 Male Standoff Locations on the WS-X67xx Module Male standoffs WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP 99716 WS-X5530 STATUS 1 Step 2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 Ensure that the connectors on the DFC3 are aligned with the connectors on the module. Figure 13 shows the connectors on the underside of the DFC3. Figure 13 DFC3A Connectors 99363 Connectors Catalyst 6500 Series DFC Memory Installation Note 78-12409-04 15 Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only) Step 3 Apply pressure to the area shown in Figure 14 to seat the power connector. Figure 14 Seating the Power Connector Apply pressure WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP STATUS 1 Caution Step 4 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 99718 WS-X5530 Use care not to damage the connectors on the module. If you damage a connector, it will be necessary to return the module to Cisco for repair. Apply pressure to the location shown in Figure 15 to fully seat the DFC3 on the module. Catalyst 6500 Series DFC Memory Installation Note 16 78-12409-04 Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only) Figure 15 Seating the DFC3 on the Module Apply pressure WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP STATUS 1 Step 5 Caution Note 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 99717 WS-X5530 Use a Phillips-head screwdriver to install the securing screws and the two cap nuts. (See Figure 16.) You must install screws in all available standoffs. The screws provide grounding between the DFC3 and the module. Failure to install all screws will invalidate the safety approvals and pose a risk of fire and electrical hazard. You should visually verify that there are standoffs beneath the mounting holes before installing the securing screws. Catalyst 6500 Series DFC Memory Installation Note 78-12409-04 17 Related Documentation Installing the Securing Screws and Cap Nuts WS-X5530 WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP STATUS 1 Step 6 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 99719 Figure 16 Install the module in the Catalyst 6500 series switch. (Refer to the Catalyst 6500 Series Module Installation Guide for installation instructions.) Related Documentation These documents are available for the Catalyst 6500 series switches: • Regulatory Compliance and Safety Information for the Catalyst 6500 Series Switches • Catalyst 6500 Series Switch Installation Guide • Catalyst 6500 Series Switch Module Installation Guide • Catalyst 6500 Series Switch Software Configuration Guide • Catalyst 6500 Series Switch Command Reference • Catalyst 6500 Series Switch Cisco IOS Software Configuration Guide • Catalyst 6500 Series Switch Cisco IOS Command Reference • Catalyst 6500 Series DFC/DFC3A Installation Note • Catalyst 6500 Series DFC3A, DFC3B, and DFC3BXL Installation Note Catalyst 6500 Series DFC Memory Installation Note 18 78-12409-04 Obtaining Documentation Obtaining Documentation Cisco documentation and additional literature are available on Cisco.com. Cisco also provides several ways to obtain technical assistance and other technical resources. These sections explain how to obtain technical information from Cisco Systems. Cisco.com You can access the most current Cisco documentation at this URL: http://www.cisco.com/univercd/home/home.htm You can access the Cisco website at this URL: http://www.cisco.com You can access international Cisco websites at this URL: http://www.cisco.com/public/countries_languages.shtml Ordering Documentation You can find instructions for ordering documentation at this URL: http://www.cisco.com/univercd/cc/td/doc/es_inpck/pdi.htm You can order Cisco documentation in these ways: • Registered Cisco.com users (Cisco direct customers) can order Cisco product documentation from the Ordering tool: http://www.cisco.com/en/US/partner/ordering/index.shtml • Nonregistered Cisco.com users can order documentation through a local account representative by calling Cisco Systems Corporate Headquarters (California, USA) at 408 526-7208 or, elsewhere in North America, by calling 800 553-NETS (6387). Documentation Feedback You can send comments about technical documentation to bug-doc@cisco.com. You can submit comments by using the response card (if present) behind the front cover of your document or by writing to the following address: Cisco Systems Attn: Customer Document Ordering 170 West Tasman Drive San Jose, CA 95134-9883 We appreciate your comments. Catalyst 6500 Series DFC Memory Installation Note 78-12409-04 19 Obtaining Technical Assistance Obtaining Technical Assistance For all customers, partners, resellers, and distributors who hold valid Cisco service contracts, Cisco Technical Support provides 24-hour-a-day, award-winning technical assistance. The Cisco Technical Support Website on Cisco.com features extensive online support resources. In addition, Cisco Technical Assistance Center (TAC) engineers provide telephone support. If you do not hold a valid Cisco service contract, contact your reseller. Cisco Technical Support Website The Cisco Technical Support Website provides online documents and tools for troubleshooting and resolving technical issues with Cisco products and technologies. The website is available 24 hours a day, 365 days a year at this URL: http://www.cisco.com/techsupport Access to all tools on the Cisco Technical Support Website requires a Cisco.com user ID and password. If you have a valid service contract but do not have a user ID or password, you can register at this URL: http://tools.cisco.com/RPF/register/register.do Submitting a Service Request Using the online TAC Service Request Tool is the fastest way to open S3 and S4 service requests. (S3 and S4 service requests are those in which your network is minimally impaired or for which you require product information.) After you describe your situation, the TAC Service Request Tool automatically provides recommended solutions. If your issue is not resolved using the recommended resources, your service request will be assigned to a Cisco TAC engineer. The TAC Service Request Tool is located at this URL: http://www.cisco.com/techsupport/servicerequest For S1 or S2 service requests or if you do not have Internet access, contact the Cisco TAC by telephone. (S1 or S2 service requests are those in which your production network is down or severely degraded.) Cisco TAC engineers are assigned immediately to S1 and S2 service requests to help keep your business operations running smoothly. To open a service request by telephone, use one of the following numbers: Asia-Pacific: +61 2 8446 7411 (Australia: 1 800 805 227) EMEA: +32 2 704 55 55 USA: 1 800 553 2447 For a complete list of Cisco TAC contacts, go to this URL: http://www.cisco.com/techsupport/contacts Definitions of Service Request Severity To ensure that all service requests are reported in a standard format, Cisco has established severity definitions. Severity 1 (S1)—Your network is “down,” or there is a critical impact to your business operations. You and Cisco will commit all necessary resources around the clock to resolve the situation. Catalyst 6500 Series DFC Memory Installation Note 20 78-12409-04 Obtaining Additional Publications and Information Severity 2 (S2)—Operation of an existing network is severely degraded, or significant aspects of your business operation are negatively affected by inadequate performance of Cisco products. You and Cisco will commit full-time resources during normal business hours to resolve the situation. Severity 3 (S3)—Operational performance of your network is impaired, but most business operations remain functional. You and Cisco will commit resources during normal business hours to restore service to satisfactory levels. Severity 4 (S4)—You require information or assistance with Cisco product capabilities, installation, or configuration. There is little or no effect on your business operations. Obtaining Additional Publications and Information Information about Cisco products, technologies, and network solutions is available from various online and printed sources. • Cisco Marketplace provides a variety of Cisco books, reference guides, and logo merchandise. Visit Cisco Marketplace, the company store, at this URL: http://www.cisco.com/go/marketplace/ • The Cisco Product Catalog describes the networking products offered by Cisco Systems, as well as ordering and customer support services. Access the Cisco Product Catalog at this URL: http://cisco.com/univercd/cc/td/doc/pcat/ • Cisco Press publishes a wide range of general networking, training and certification titles. Both new and experienced users will benefit from these publications. For current Cisco Press titles and other information, go to Cisco Press at this URL: http://www.ciscopress.com • Packet magazine is the Cisco Systems technical user magazine for maximizing Internet and networking investments. Each quarter, Packet delivers coverage of the latest industry trends, technology breakthroughs, and Cisco products and solutions, as well as network deployment and troubleshooting tips, configuration examples, customer case studies, certification and training information, and links to scores of in-depth online resources. You can access Packet magazine at this URL: http://www.cisco.com/packet • iQ Magazine is the quarterly publication from Cisco Systems designed to help growing companies learn how they can use technology to increase revenue, streamline their business, and expand services. The publication identifies the challenges facing these companies and the technologies to help solve them, using real-world case studies and business strategies to help readers make sound technology investment decisions. You can access iQ Magazine at this URL: http://www.cisco.com/go/iqmagazine • Internet Protocol Journal is a quarterly journal published by Cisco Systems for engineering professionals involved in designing, developing, and operating public and private internets and intranets. You can access the Internet Protocol Journal at this URL: http://www.cisco.com/ipj • World-class networking training is available from Cisco. You can view current offerings at this URL: http://www.cisco.com/en/US/learning/index.html Catalyst 6500 Series DFC Memory Installation Note 78-12409-04 21 Obtaining Additional Publications and Information This document is to be used in conjunction with the documents listed in the “Related Documentation” section. CCSP, the Cisco Square Bridge logo, Cisco Unity, Follow Me Browsing, FormShare, and StackWise are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, GigaDrive, GigaStack, HomeLink, Internet Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, LightStream, Linksys, MeetingPlace, MGX, the Networkers logo, Networking Academy, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, ProConnect, RateMUX, Registrar, ScriptShare, SlideCast, SMARTnet, StrataView Plus, SwitchProbe, TeleRouter, The Fastest Way to Increase Your Internet Quotient, TransPath, and VCO are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries. All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0406R) Copyright © 2001–2004 Cisco Systems, Inc. All rights reserved. Catalyst 6500 Series DFC Memory Installation Note 22 78-12409-04