Laserlite Brochure

Transcription

Laserlite Brochure
extend your
outdoor
lifestyle
www.laserlite.com.au
Up to 50%
better heat
reduction
than standard
corrugated
sheet#
only
®
Laserlite has
the technology
Laserlite® is the only polycarbonate corrugated sheet
product in Australia featuring
Advanced Weatherguard™ technology, a special protective
material that is warranted to
• Extend the life of the sheet by up to 50%#
• Maintain sheet colour and clarity up to 50% longer#
• Provide 99.9% protection from UV rays up to 50% longer#
• Resist 25% larger hailstones#
With unrivalled technology and superior performance, it’s
clear why Laserlite® is part of the Australian outdoor lifestyle.
Comfort Cool™ keeps you cool and comfortable.
Laserlite 3000 is the only polycarbonate roofing product to
feature Comfort Cool™ Technology, special properties in the
sheet that reflect the warming effect of the sun’s rays to offer
• Up to 50% better heat reduction than standard
corrugated sheet#
• reduced glare for ultimate comfort
# As compared to some other polycarbonate corrugated sheet products.
How it works
UV rays, wind, hail and rain have the potential to make
polycarbonate resins brittle and lose colour over time.
TM
Advanced Weatherguard protects the sheet and
protects from harmful UV radiation.
How it works
Infra red light emitted by the sun passes through
polycarbonate sheet making it warm underneath.
Comfort Cool™ Technology reflects the heat away whilst
letting visible light through with less glare.
Performance & reliability
1. SELECT PRODUCT
The Classic,high performing Laserlite® range.
PRODUCT TECHNOLOGIES
• Lifetime Platinum Warranty*
• Certified to Australian standards
2. SELECT COLOUR
clear
opal
Light
93%
49%
Transmission %
Heat ‡
0%
52%
Reduction %
cream
bronze
tint
grey
tint
43%
38%
19%
62%
33%
47%
3. SELECT PROFILE
corrugated
greca
5 - rib
4. SELECT LENGTH
Laserlite® 2000
Lengths available - 1.8m, 2.4m, 3.0m, 3.6m, 4.2m
4.8m, 5.4m, 6.0m, 7.2m, 9.0m
Sheet width Corrugated 840mm Greca 810mm 5 - rib 830mm
Cover width
Corrugated 755mm Greca 760mm 5 - rib 762mm
‡ Based on the warming effect of the sun’s rays through a sheet vs 3mm float glass (300-2500nm).
Light level
clear
opal
cream bronze tint
MORE LIGHT
Comfort level
WARMER
clear
grey tint
LESS LIGHT
bronze
tint
grey
tint
opal
cream
COOLER
Ultimate comfort
1. SELECT PRODUCT
Technologically advanced heat reflective range
for the ultimate outdoor lifestyle experience.
PRODUCT TECHNOLOGIES
• Lifetime Platinum Warranty*
• Certified to Australian standards
With Comfort CoolTM Technology
2. SELECT COLOUR
platinum
ice
gun
metal
Light 18%
Transmission %
47%
16%
Heat ‡
Reduction %
63%
66%
69%
Up to 50%
better heat
reduction
performance
than standard
corrugated
sheet!#
3. SELECT PROFILE
corrugated
greca
4. SELECT LENGTH
Laserlite® 3000
Lengths available - 1.8m, 2.4m, 3.0m, 3.6m, 4.2m,
4.8m, 5.4m, 6.0m, 7.2m, 9.0m
Sheet width Corrugated 840mm Greca 810mm
Cover width
Corrugated 755mm Greca 760mm ‡ Based on the warming effect of the sun’s rays through a sheet vs 3mm float glass (300-2500nm).
# As compared to some other polycarbonate corrugated sheet products.
Light level
ice
platinum gun metal
MORE LIGHT
Comfort level
WARMER
LESS LIGHT
ice gun platinum
metal
COOLER
Installation Guide
1
Purlins & accessories
Safety Recommendations
3. For roof laying, start with the lower
Table Z – Side Laps
sheets first, keeping side laps away
from
Apron Flashing
Profile
End Span
Mid Span
1/2 corrugations
Purlins
prevailing wind. Allow an overhang
Romaof
– 1 50mm.
Roma
800mm
1000mm
Temperature
changes
will
cause
expansion
and
Greca
900mm
1200mm
Rafters
contraction, so make
allowances
for thermal
Trimdek 900mm
1200mm
Greca – 1 corrugation
Capping &
movement. Resistance to movement
can
Barge
Capping
cause
buckling.
Table
Y – Fixing
Spacings
for various
Greca
Trimdek
8
9
10
2
Sheet & fixings
CAUTION – To maximise the life of your Laserlite roofing, Laserlite recommends
to avoid exposing your polycarbonate sheeting to excess heat from patio heaters.
Laserlite recommends a distance of 1m is kept between the sheets and the
heater, adequate ventilation at all times and temperature to be below 90ºC
beneath the sheeting. If temperature underneath your sheet rises above 90ºC,
immediately remove the patio heater from underneath the polycarbonate sheeting.
1. Ensure that the UV surface protected side
faces the sun. This is the side of the label and
the inkjet marking. When installed as a wall or
fence it is recommended that the UV protected
side is facing the most sun. The life of the
sheet may be shortened and discolouration
may occur due to the unprotected side being
exposed to UV radiation.
Foam Infill
Back Channel Flashing
Purlin end span spacing
(refer Table X)
Laserlite screws
Laserlite Polycarbonate Roof
and weatherseals
(refer Table Y for spacing)
Purlin
5 Rib - 1 corrugations
Product Performance
Gutter
XPT
Classic Cream 0.30
0.31
0.33
Satin Cream
Metallic Bronze 0.34
0.35
0.34
0.36
0.35
Coolest
0.31
Apollo
0.32
2000
Prevailing Wind Direction
0.39
0.50
0.43
0.53
Fascia
Ocean Blue
0.55
1.01
0.68
Shading Co-efficient Ratio (SC)
Warmest
UNDER A GUTTER - Fit Back channel
flashing with foam infill strips under gutter
prior to laying sheets and Barge Capping to
edge of sheet.
Olive Mica
Platinum
Metallic Bronze 15%
15%
13%
Steel
Gun Metal
15%
Olive Mica
Steel
18%
17%
19%
Gumleaf
Platinum
19%
Grey Tint
Ocean Blue
28%
Satin Sage
Satin Sage
Stone
Ivory
Arctic Ice
35%
Ivory
29%
35%
Bronze Tint
Stone
44%
Classic Cream 33%
Gumleaf
51%
Gun Metal
5. To ensure maximum performance of the
Foam Infill
sheet,
and to avoid buckling, it is necessary to
Back Channel Flashing
oversize the holes
and centre the fixings. It is
Purlin
Laserlite Polycarbonate Roof
Shading Co-efficient (SC): A ratio of the warming effect of the
rays through a®
divided by the sun’s
recommended that Laserlite® sun’s
One
Shot sheetfixings
warming effect through 3mm float glass (300-2500nm). The lower the figure the cooler it is under the sheet.
are
used.
They
come
complete
with
their
own
Light Transmission (LT)
More Light
Less Light
hole
saw that cuts an expansion hole as you drill.
The screw is centred every time and the cutter
holds the plug of material removed. If using
Laserlite® Standard Fixings, pre-drill your fixing
holes. Use a 10mm drill for sheets up to 4.2mm
long and a 12mm drill for sheets longer than
AGAINST A WALL/FASCIA - Fit barge
Light Transmission (LT): % of visible light transmission (400-700nm) that passes through the sheet.
4.2mm.
Fix the sheet through the cerntre of the
The lower the figure the less light passes through the sheet.
capping to edge of sheet and apron flashing
pre-drilled holes, perpendicular to the purlins/
at the wall or fascia. Secure using One
battens. A (5/16”) Drill hex driver bit should be
Shot® screws.
used. Only tighten the fixings enough to prevent
Clear
264mm
Step
• Refer to Safety Recommendations.
• Installations must comply with the applicable building code.
• We do not recommend the collection of drinking water from any roof
without appropriate precautions and filtration. Check with your local
water authority for further advice.
Fascia
Greca - 1 1/2 corrugations
Purlin mid span spacing
(refer Table X)
Arctic Ice
7
Barge
Capping
Satin Cream
Rafters
56%
6
Gutter
Corrugated - 1 1/2 corrugations
93%
5
build-up
and provide
air circulation.particularly
Good ventilationatwill
also minimise
2. Allow
for ventilation,
the
condensation in5˚
cold weather.
highest
point,
to
minimise
heat
build-up
and
Forroofing,purlin/battenspacingsshouldbenomorethanthose
shown
in Tableair
X – circulation.
Maximum PurlinGood
Spacings.
For curved structures,
the
provide
ventilation
will
maximum purlin spacing should be 750mm and a minimum radius of
also minimise condensation in cold weather.
6000mm for Roma and Greca profile and 14000mm for Trimdek profile.
For walls, nogging spacings should be no more than 1200mm. Use
3. For
roofing,
purlin/batten
spacings
should
Laserlite
Noise
Stop Tape
on all battens, purlins
or noggings
to
minimise
noises than
associated
withshown
expansioninand
contraction.
be nothemore
those
Table
Ensure
UV surface Purlin
protected
side faces the
sun.curved
This is the side of
X - the
Maximum
Spacings.
For
the label and the inkjet marking. When installed as a wall or fence it is
structures,
maximum
purlin
spacing
recommended
thatthe
the UV
protected side
is facing
the most sun. The
life should
of the sheet
be shortened
discolouration
may occur
bemay
750mm
andand
a minimum
radius
of due
to the unprotected side being exposed to UV radiation.
4000mm for Corrugated and Greca profile and
The sheet can be easily cut with a pair of shears, a fine-toothed
14000mm
for saw
5 Rib
For walls,
nogging
handsaw
or a circular
withprofile.
a cut-off blade
suitable for
plastic.
In spacings
normal conditions,
use be
the fixing
spacings
shown
in Table Y – Fixing
shoud
no more
that
1200mm.
Spacings. As a guide,
approximately 7 fixings per lineal
®you will need
UseThis
Laserlite
Stop
on and
all wind
battens,
metre.
depends on Noise
your purlin
spacings
conditions. In high
wind
areas fixorRoma
and Greca
every second
corrugation
purlins
noggings
toonminimise
the
noises on each
purlin/batten.Itissuggestedthatbargecappingbeused.Fixthe
associated with expansion and contraction.
sheet through the crests for roofing with Laserlite One-Shot Fixings
and through the valleys for
walls with Laserlite Fixings for Cladding
® Noise
Lay Standard
Laserlite
Stop Tape to avoid
or 4.
Laserlite
Fixings.
Forcreaking.
roof laying, start with the lower sheets first, keeping side laps away
from prevailing wind. Allow an overhang of 50mm. Temperature changes
will5.
cause
and®contraction,
so make
allowances
for thermal
Layexpansion
Laserlite
Eave Infill
strips
at eaves
to
movement. Resistance to movement can cause buckling.
avoid rain,dust & wind entering the eaves.
To ensure maximum performance of the sheet, and to avoid buckling,
it is necessary to oversize the holes and centre the fixings. It is
6. For installations
gutter,
Metal
recommended
that Laserlite under
One-ShotaFixings
are fit
used.
They come
complete
their ownwith
hole saw
that channel
cuts an expansion
hole as you
back with
channel
Back
infill strips
drill. The screw is centred every time and the cutter holds the plug of
prior
to
laying
sheet.
material removed. If using Laserlite Fixings for Cladding or Laserlite
Standard Fixings, pre-drill your fixing holes. Use a 10mm drill for sheets
up to 4.2m long and a 12mm drill for sheets longer than 4.2m. Fix
- Maximum
Purlin Spacings
the sheetTable
throughXthe
centre of the pre-drilled
holes, perpendicular
tothepurlins/battens.A(5/16”)Drillhexdriverbitshouldbeused.
Profile
EndtoSpan
Mid
Span
Only tighten
the fixings enough
prevent rattling.
Over-tightening
may cause
distortion and undue
stress with possible
failure resulting.
Corrugated
800mm
1000mm
Use only Laserlite branded fixings as these are designed to be
Greca
900mm Roofing.1200mm
compatible
with Laserlite Polycarbonate
Any failure
of the sheet due
to fixings other than1200mm
Laserlite branded
5 Rib
900mm
will void the Laserlite warranty.
Sidelapswilldifferbyprofile.InstallasshowninTableZ.
End overlaps should be 150mm for steep pitch or 200mm
for shallow pitch.
APEX ROOF - Fit barge capping to edge of
sheet and ridge capping to the apex. Secure
using One Shot® screws
and weatherseals
(refer Table Y for spacing)
Purlins
Opal
particularly at the highest point, to minimise heat
2 Allow for ventilation,
3 metres
flashings
installations
Prevailing
Wind
Direction
Laserlite
screws
Every crest
Clear
5˚
264mm
88mm
3 met
Every crest
(refer Table X)
Table Y - Side
laps
Apron Flashing
88mm
Carefully read all installation instructions before you start.
1. Ensure
that your
roof
pitch
at least
5°,office
• For installation
in cyclonic
regions,
contact
yourisnearest
Laserlite
metre
for special
instructions.
ie. 88mm
rise per lineal metre.This 1will
ensure
5˚
that your water
roof pitchrun
is atoff.
least 5º, i.e. 88mm rise per lineal metre.
adequate
1 Ensure
This will ensure adequate water run off.
res
4
Every 2nd crest Every 3rd crest
Opal
Installation Instructions
Trimdek – 1 corrugation
Purlins
Mid PurlinsPurlin mid span spacing
4. Side End
laps
will differ
by profile.
as
(refer Install
Table X)
Every 2nd crest Every 3rd crest
shown below:
Purlin end span spacing
Profile
Roma
Grey Tint
wind entering eaves
3
3
Table X – Maximum Purlin Spacings
• Always exercise extreme care when walking on any roof.
• Never walk on or apply a load or your weight directly to sheeting.
• In particular consider all safety requirements when working at heights
above 2m.Noise Stop Tape
Reduce creaking
• For Safety precautions we recommend the use of safety mesh for
installations above 3m.
• Use appropriate personal protective equipment (PPE) such as safety
footwear, safety glasses and gloves.
Eave
Infill
Strips
• All safety practices must comply
with
the
applicable local building
and/or work cover code(s). Prevent rain, dust and
1 metre
5˚
Step
2. The sheet can be easily cut with a pair of
shears, a fine-toothed handsaw or a circular
saw with a cut-off blade suitable for plastic.
Bronze Tint
Step
Product Range
Profiles
rattling. Over tightening may cause distortion
cover width
and undue stress with possible
failure resulting.
760mm
sheet width
840mm
Use only Laserlite® branded
fixings as these
thickness = 0.8mm
76mm
are designed to be compatible with Laserlite®
Polycarbonate
Roofing. Any failure of the sheet
Greca
cover width
® branded
760mm
due to fixings other than Laserlite
will
sheet width
815mm
®
thickness = 0.8mm
25 warranty.
25
void the Laserlite
mm
mm
76mm
20mm
In normal conditions, use the fixing spacings
shown in Table Z - Fixing spacings.
Trimdek
cover width
762mm
As a guide, you will need approximately
7 sheet width
25
830mm
mm
13mm thickness
191mm This depends on your
fixings
per= 0.8mm
lineal metre.
29mm
60 high
purlin spacings and wind conditions. In
mm
170˚
wind areas fix Corrugated
and Greca on every
second corrugation on each purlin/batten. It is
Weight
Roma
Trimdek
suggested that barge
capping beGreca
used. Fix the
Kg per Lineal Metre
0.92
0.92
®
sheet through the valleys
for walls0.93
with Laserlite
Kg per m2
1.10
1.13
1.11
Standard Fixings.
Roma
Available Sizes
Standard lengths in metres: 1.8, 2.4, 3.0, 3.6, 4.2, 4.8, 5.4, 6.0, 7.2
TableupZto-10Fixing
Lengths
metres Spacing
can be ordered (conditions apply)
Profile
End Purlin
Corrugated every 2nd crest
Greca
every 2nd crest
5 Rib
every crest
Mid Purlins
every 3rd crest
every 3rd crest
every crest
Using One Shot® fixings eliminates requirement
for pre-drilling.
6. End overlaps should be 150mm for steep
pitch or 200mm for shallow pitch.
Safety Recommendations
- Always exercise extreme care when walking
on a roof.
- Never walk on or apply your load directly to
sheeting.
- In particular consider all safety requirements
18mm
when working at heights above 2m.
- For safety reasons we recommend the use
of safety mesh for installations above 3m.
25mm
- Use appropriate personal protective
equipment (PPE) such as safety footwear,
glasses & gloves.
- All safety practices must comply with the
applicable local building and/or work cover
code(s).
- We do not recommend the collection
of drinking water from any roof without
appropriate precautions and filtration.Check
with your local water authority for further
advice.
18mm
CAUTION: To maximise the life cycle of your
Laserlite® roofing. Laserlite® recommends
avoiding exposure of polycarbonate sheeting
to excess heat from patio heaters. Maintain
a distance of 1 metre minimum between the
sheets and the heater with adequate ventilation
at all times and temperature to below 90°C
beneath the sheeting. If the temperature rises
above 90°C, remove the heater immediately.
the complete solution
for a professional finish
1
3
Noise stop tape
Reduces creaking
Barge capping
Prevents wind & rain
entering the gable
ends
2
4
Ridge capping
Prevents roof
leaking at apex
When installed against a wall
Back channel & infill
Prevents leaking at
walls and facias
4
Eave infill strips
Prevents rain,dust
and wind entering the eaves
Apron flashing
Prevents leaking at
walls and facias
1
Easy to install, Laserlite®
has a quality range of
3
accessories to make your
installation complete and ensure
a professional finish.
2
Laserlite® One Shot® Time Saving Fixing System
saves 50% installation time as no pre-drilling is required.
They also feature a Class 4 coating for superior corrosion
resistance and suitability for coastal areas.
Save 50%
installation
time
New South Wales T 02 9677 9900
F 02 9677 9500
E nswmbp@mulford.com.au
Victoria
T 03 8791 8000
F 03 8791 8088
E vicmbp@mulford.com.au
Queensland T 07 3717 4700
F 07 3717 4777
E qldmbp@mulford.com.au
South Australia T 08 8444 9666
F 08 8444 9600
E sambp@mulford.com.au
Western Australia T 08 9240 6655
F 08 9240 8877
E wambp@mulford.com.au
* For Warranty details, refer to our website www.laserlite.com.au. Colours depicted in this brochure are representations offered only as a guide and should not form the basis of a
colour selection. Slight colour variation may occur between production runs. Transmitted light and colour may vary in intensity depending on weather conditions. The information
contained in this brochure is to the best of our knowledge accurate, but all recommendations are made without any warranty whatsoever, since the conditions of use are beyond our
control. This brochure cancels and supersedes all previous publicised information. The company reserves the right to alter and revise, without notice, the information contained herein.