Laserlite Brochure
Transcription
Laserlite Brochure
extend your outdoor lifestyle www.laserlite.com.au Up to 50% better heat reduction than standard corrugated sheet# only ® Laserlite has the technology Laserlite® is the only polycarbonate corrugated sheet product in Australia featuring Advanced Weatherguard™ technology, a special protective material that is warranted to • Extend the life of the sheet by up to 50%# • Maintain sheet colour and clarity up to 50% longer# • Provide 99.9% protection from UV rays up to 50% longer# • Resist 25% larger hailstones# With unrivalled technology and superior performance, it’s clear why Laserlite® is part of the Australian outdoor lifestyle. Comfort Cool™ keeps you cool and comfortable. Laserlite 3000 is the only polycarbonate roofing product to feature Comfort Cool™ Technology, special properties in the sheet that reflect the warming effect of the sun’s rays to offer • Up to 50% better heat reduction than standard corrugated sheet# • reduced glare for ultimate comfort # As compared to some other polycarbonate corrugated sheet products. How it works UV rays, wind, hail and rain have the potential to make polycarbonate resins brittle and lose colour over time. TM Advanced Weatherguard protects the sheet and protects from harmful UV radiation. How it works Infra red light emitted by the sun passes through polycarbonate sheet making it warm underneath. Comfort Cool™ Technology reflects the heat away whilst letting visible light through with less glare. Performance & reliability 1. SELECT PRODUCT The Classic,high performing Laserlite® range. PRODUCT TECHNOLOGIES • Lifetime Platinum Warranty* • Certified to Australian standards 2. SELECT COLOUR clear opal Light 93% 49% Transmission % Heat ‡ 0% 52% Reduction % cream bronze tint grey tint 43% 38% 19% 62% 33% 47% 3. SELECT PROFILE corrugated greca 5 - rib 4. SELECT LENGTH Laserlite® 2000 Lengths available - 1.8m, 2.4m, 3.0m, 3.6m, 4.2m 4.8m, 5.4m, 6.0m, 7.2m, 9.0m Sheet width Corrugated 840mm Greca 810mm 5 - rib 830mm Cover width Corrugated 755mm Greca 760mm 5 - rib 762mm ‡ Based on the warming effect of the sun’s rays through a sheet vs 3mm float glass (300-2500nm). Light level clear opal cream bronze tint MORE LIGHT Comfort level WARMER clear grey tint LESS LIGHT bronze tint grey tint opal cream COOLER Ultimate comfort 1. SELECT PRODUCT Technologically advanced heat reflective range for the ultimate outdoor lifestyle experience. PRODUCT TECHNOLOGIES • Lifetime Platinum Warranty* • Certified to Australian standards With Comfort CoolTM Technology 2. SELECT COLOUR platinum ice gun metal Light 18% Transmission % 47% 16% Heat ‡ Reduction % 63% 66% 69% Up to 50% better heat reduction performance than standard corrugated sheet!# 3. SELECT PROFILE corrugated greca 4. SELECT LENGTH Laserlite® 3000 Lengths available - 1.8m, 2.4m, 3.0m, 3.6m, 4.2m, 4.8m, 5.4m, 6.0m, 7.2m, 9.0m Sheet width Corrugated 840mm Greca 810mm Cover width Corrugated 755mm Greca 760mm ‡ Based on the warming effect of the sun’s rays through a sheet vs 3mm float glass (300-2500nm). # As compared to some other polycarbonate corrugated sheet products. Light level ice platinum gun metal MORE LIGHT Comfort level WARMER LESS LIGHT ice gun platinum metal COOLER Installation Guide 1 Purlins & accessories Safety Recommendations 3. For roof laying, start with the lower Table Z – Side Laps sheets first, keeping side laps away from Apron Flashing Profile End Span Mid Span 1/2 corrugations Purlins prevailing wind. Allow an overhang Romaof – 1 50mm. Roma 800mm 1000mm Temperature changes will cause expansion and Greca 900mm 1200mm Rafters contraction, so make allowances for thermal Trimdek 900mm 1200mm Greca – 1 corrugation Capping & movement. Resistance to movement can Barge Capping cause buckling. Table Y – Fixing Spacings for various Greca Trimdek 8 9 10 2 Sheet & fixings CAUTION – To maximise the life of your Laserlite roofing, Laserlite recommends to avoid exposing your polycarbonate sheeting to excess heat from patio heaters. Laserlite recommends a distance of 1m is kept between the sheets and the heater, adequate ventilation at all times and temperature to be below 90ºC beneath the sheeting. If temperature underneath your sheet rises above 90ºC, immediately remove the patio heater from underneath the polycarbonate sheeting. 1. Ensure that the UV surface protected side faces the sun. This is the side of the label and the inkjet marking. When installed as a wall or fence it is recommended that the UV protected side is facing the most sun. The life of the sheet may be shortened and discolouration may occur due to the unprotected side being exposed to UV radiation. Foam Infill Back Channel Flashing Purlin end span spacing (refer Table X) Laserlite screws Laserlite Polycarbonate Roof and weatherseals (refer Table Y for spacing) Purlin 5 Rib - 1 corrugations Product Performance Gutter XPT Classic Cream 0.30 0.31 0.33 Satin Cream Metallic Bronze 0.34 0.35 0.34 0.36 0.35 Coolest 0.31 Apollo 0.32 2000 Prevailing Wind Direction 0.39 0.50 0.43 0.53 Fascia Ocean Blue 0.55 1.01 0.68 Shading Co-efficient Ratio (SC) Warmest UNDER A GUTTER - Fit Back channel flashing with foam infill strips under gutter prior to laying sheets and Barge Capping to edge of sheet. Olive Mica Platinum Metallic Bronze 15% 15% 13% Steel Gun Metal 15% Olive Mica Steel 18% 17% 19% Gumleaf Platinum 19% Grey Tint Ocean Blue 28% Satin Sage Satin Sage Stone Ivory Arctic Ice 35% Ivory 29% 35% Bronze Tint Stone 44% Classic Cream 33% Gumleaf 51% Gun Metal 5. To ensure maximum performance of the Foam Infill sheet, and to avoid buckling, it is necessary to Back Channel Flashing oversize the holes and centre the fixings. It is Purlin Laserlite Polycarbonate Roof Shading Co-efficient (SC): A ratio of the warming effect of the rays through a® divided by the sun’s recommended that Laserlite® sun’s One Shot sheetfixings warming effect through 3mm float glass (300-2500nm). The lower the figure the cooler it is under the sheet. are used. They come complete with their own Light Transmission (LT) More Light Less Light hole saw that cuts an expansion hole as you drill. The screw is centred every time and the cutter holds the plug of material removed. If using Laserlite® Standard Fixings, pre-drill your fixing holes. Use a 10mm drill for sheets up to 4.2mm long and a 12mm drill for sheets longer than AGAINST A WALL/FASCIA - Fit barge Light Transmission (LT): % of visible light transmission (400-700nm) that passes through the sheet. 4.2mm. Fix the sheet through the cerntre of the The lower the figure the less light passes through the sheet. capping to edge of sheet and apron flashing pre-drilled holes, perpendicular to the purlins/ at the wall or fascia. Secure using One battens. A (5/16”) Drill hex driver bit should be Shot® screws. used. Only tighten the fixings enough to prevent Clear 264mm Step • Refer to Safety Recommendations. • Installations must comply with the applicable building code. • We do not recommend the collection of drinking water from any roof without appropriate precautions and filtration. Check with your local water authority for further advice. Fascia Greca - 1 1/2 corrugations Purlin mid span spacing (refer Table X) Arctic Ice 7 Barge Capping Satin Cream Rafters 56% 6 Gutter Corrugated - 1 1/2 corrugations 93% 5 build-up and provide air circulation.particularly Good ventilationatwill also minimise 2. Allow for ventilation, the condensation in5˚ cold weather. highest point, to minimise heat build-up and Forroofing,purlin/battenspacingsshouldbenomorethanthose shown in Tableair X – circulation. Maximum PurlinGood Spacings. For curved structures, the provide ventilation will maximum purlin spacing should be 750mm and a minimum radius of also minimise condensation in cold weather. 6000mm for Roma and Greca profile and 14000mm for Trimdek profile. For walls, nogging spacings should be no more than 1200mm. Use 3. For roofing, purlin/batten spacings should Laserlite Noise Stop Tape on all battens, purlins or noggings to minimise noises than associated withshown expansioninand contraction. be nothemore those Table Ensure UV surface Purlin protected side faces the sun.curved This is the side of X - the Maximum Spacings. For the label and the inkjet marking. When installed as a wall or fence it is structures, maximum purlin spacing recommended thatthe the UV protected side is facing the most sun. The life should of the sheet be shortened discolouration may occur bemay 750mm andand a minimum radius of due to the unprotected side being exposed to UV radiation. 4000mm for Corrugated and Greca profile and The sheet can be easily cut with a pair of shears, a fine-toothed 14000mm for saw 5 Rib For walls, nogging handsaw or a circular withprofile. a cut-off blade suitable for plastic. In spacings normal conditions, use be the fixing spacings shown in Table Y – Fixing shoud no more that 1200mm. Spacings. As a guide, approximately 7 fixings per lineal ®you will need UseThis Laserlite Stop on and all wind battens, metre. depends on Noise your purlin spacings conditions. In high wind areas fixorRoma and Greca every second corrugation purlins noggings toonminimise the noises on each purlin/batten.Itissuggestedthatbargecappingbeused.Fixthe associated with expansion and contraction. sheet through the crests for roofing with Laserlite One-Shot Fixings and through the valleys for walls with Laserlite Fixings for Cladding ® Noise Lay Standard Laserlite Stop Tape to avoid or 4. Laserlite Fixings. Forcreaking. roof laying, start with the lower sheets first, keeping side laps away from prevailing wind. Allow an overhang of 50mm. Temperature changes will5. cause and®contraction, so make allowances for thermal Layexpansion Laserlite Eave Infill strips at eaves to movement. Resistance to movement can cause buckling. avoid rain,dust & wind entering the eaves. To ensure maximum performance of the sheet, and to avoid buckling, it is necessary to oversize the holes and centre the fixings. It is 6. For installations gutter, Metal recommended that Laserlite under One-ShotaFixings are fit used. They come complete their ownwith hole saw that channel cuts an expansion hole as you back with channel Back infill strips drill. The screw is centred every time and the cutter holds the plug of prior to laying sheet. material removed. If using Laserlite Fixings for Cladding or Laserlite Standard Fixings, pre-drill your fixing holes. Use a 10mm drill for sheets up to 4.2m long and a 12mm drill for sheets longer than 4.2m. Fix - Maximum Purlin Spacings the sheetTable throughXthe centre of the pre-drilled holes, perpendicular tothepurlins/battens.A(5/16”)Drillhexdriverbitshouldbeused. Profile EndtoSpan Mid Span Only tighten the fixings enough prevent rattling. Over-tightening may cause distortion and undue stress with possible failure resulting. Corrugated 800mm 1000mm Use only Laserlite branded fixings as these are designed to be Greca 900mm Roofing.1200mm compatible with Laserlite Polycarbonate Any failure of the sheet due to fixings other than1200mm Laserlite branded 5 Rib 900mm will void the Laserlite warranty. Sidelapswilldifferbyprofile.InstallasshowninTableZ. End overlaps should be 150mm for steep pitch or 200mm for shallow pitch. APEX ROOF - Fit barge capping to edge of sheet and ridge capping to the apex. Secure using One Shot® screws and weatherseals (refer Table Y for spacing) Purlins Opal particularly at the highest point, to minimise heat 2 Allow for ventilation, 3 metres flashings installations Prevailing Wind Direction Laserlite screws Every crest Clear 5˚ 264mm 88mm 3 met Every crest (refer Table X) Table Y - Side laps Apron Flashing 88mm Carefully read all installation instructions before you start. 1. Ensure that your roof pitch at least 5°,office • For installation in cyclonic regions, contact yourisnearest Laserlite metre for special instructions. ie. 88mm rise per lineal metre.This 1will ensure 5˚ that your water roof pitchrun is atoff. least 5º, i.e. 88mm rise per lineal metre. adequate 1 Ensure This will ensure adequate water run off. res 4 Every 2nd crest Every 3rd crest Opal Installation Instructions Trimdek – 1 corrugation Purlins Mid PurlinsPurlin mid span spacing 4. Side End laps will differ by profile. as (refer Install Table X) Every 2nd crest Every 3rd crest shown below: Purlin end span spacing Profile Roma Grey Tint wind entering eaves 3 3 Table X – Maximum Purlin Spacings • Always exercise extreme care when walking on any roof. • Never walk on or apply a load or your weight directly to sheeting. • In particular consider all safety requirements when working at heights above 2m.Noise Stop Tape Reduce creaking • For Safety precautions we recommend the use of safety mesh for installations above 3m. • Use appropriate personal protective equipment (PPE) such as safety footwear, safety glasses and gloves. Eave Infill Strips • All safety practices must comply with the applicable local building and/or work cover code(s). Prevent rain, dust and 1 metre 5˚ Step 2. The sheet can be easily cut with a pair of shears, a fine-toothed handsaw or a circular saw with a cut-off blade suitable for plastic. Bronze Tint Step Product Range Profiles rattling. Over tightening may cause distortion cover width and undue stress with possible failure resulting. 760mm sheet width 840mm Use only Laserlite® branded fixings as these thickness = 0.8mm 76mm are designed to be compatible with Laserlite® Polycarbonate Roofing. Any failure of the sheet Greca cover width ® branded 760mm due to fixings other than Laserlite will sheet width 815mm ® thickness = 0.8mm 25 warranty. 25 void the Laserlite mm mm 76mm 20mm In normal conditions, use the fixing spacings shown in Table Z - Fixing spacings. Trimdek cover width 762mm As a guide, you will need approximately 7 sheet width 25 830mm mm 13mm thickness 191mm This depends on your fixings per= 0.8mm lineal metre. 29mm 60 high purlin spacings and wind conditions. In mm 170˚ wind areas fix Corrugated and Greca on every second corrugation on each purlin/batten. It is Weight Roma Trimdek suggested that barge capping beGreca used. Fix the Kg per Lineal Metre 0.92 0.92 ® sheet through the valleys for walls0.93 with Laserlite Kg per m2 1.10 1.13 1.11 Standard Fixings. Roma Available Sizes Standard lengths in metres: 1.8, 2.4, 3.0, 3.6, 4.2, 4.8, 5.4, 6.0, 7.2 TableupZto-10Fixing Lengths metres Spacing can be ordered (conditions apply) Profile End Purlin Corrugated every 2nd crest Greca every 2nd crest 5 Rib every crest Mid Purlins every 3rd crest every 3rd crest every crest Using One Shot® fixings eliminates requirement for pre-drilling. 6. End overlaps should be 150mm for steep pitch or 200mm for shallow pitch. Safety Recommendations - Always exercise extreme care when walking on a roof. - Never walk on or apply your load directly to sheeting. - In particular consider all safety requirements 18mm when working at heights above 2m. - For safety reasons we recommend the use of safety mesh for installations above 3m. 25mm - Use appropriate personal protective equipment (PPE) such as safety footwear, glasses & gloves. - All safety practices must comply with the applicable local building and/or work cover code(s). - We do not recommend the collection of drinking water from any roof without appropriate precautions and filtration.Check with your local water authority for further advice. 18mm CAUTION: To maximise the life cycle of your Laserlite® roofing. Laserlite® recommends avoiding exposure of polycarbonate sheeting to excess heat from patio heaters. Maintain a distance of 1 metre minimum between the sheets and the heater with adequate ventilation at all times and temperature to below 90°C beneath the sheeting. If the temperature rises above 90°C, remove the heater immediately. the complete solution for a professional finish 1 3 Noise stop tape Reduces creaking Barge capping Prevents wind & rain entering the gable ends 2 4 Ridge capping Prevents roof leaking at apex When installed against a wall Back channel & infill Prevents leaking at walls and facias 4 Eave infill strips Prevents rain,dust and wind entering the eaves Apron flashing Prevents leaking at walls and facias 1 Easy to install, Laserlite® has a quality range of 3 accessories to make your installation complete and ensure a professional finish. 2 Laserlite® One Shot® Time Saving Fixing System saves 50% installation time as no pre-drilling is required. They also feature a Class 4 coating for superior corrosion resistance and suitability for coastal areas. Save 50% installation time New South Wales T 02 9677 9900 F 02 9677 9500 E nswmbp@mulford.com.au Victoria T 03 8791 8000 F 03 8791 8088 E vicmbp@mulford.com.au Queensland T 07 3717 4700 F 07 3717 4777 E qldmbp@mulford.com.au South Australia T 08 8444 9666 F 08 8444 9600 E sambp@mulford.com.au Western Australia T 08 9240 6655 F 08 9240 8877 E wambp@mulford.com.au * For Warranty details, refer to our website www.laserlite.com.au. Colours depicted in this brochure are representations offered only as a guide and should not form the basis of a colour selection. Slight colour variation may occur between production runs. Transmitted light and colour may vary in intensity depending on weather conditions. The information contained in this brochure is to the best of our knowledge accurate, but all recommendations are made without any warranty whatsoever, since the conditions of use are beyond our control. This brochure cancels and supersedes all previous publicised information. The company reserves the right to alter and revise, without notice, the information contained herein.