wolf ventilation guide
Transcription
wolf ventilation guide
WOLF VENTILATION GUIDE Contents Important Note Wolf Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Wolf cooking products do not require ventilation when installed according to the installation instructions. Recommendations and suggestions in this guide are for performance only. Selecting a Ventilation System . . . . . . . . . . . . . . . . . . . 4 Ventilation Made Easy . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Wolf Cooktop Ventilation . . . . . . . . . . . . . . . . . . . . . . 14 Wolf Pro Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Wolf Blower Specifications . . . . . . . . . . . . . . . . . . . . . 44 Wolf Ventilation FAQ . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Wolf Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Features and specifications are subject to change at any time without notice. Visit our website, wolfappliance.com for the most up-to-date information. IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified. IMPORTANT NOTE: Wolf prefers an HVAC contractor approve the airflow characteristics of any ventilation and duct work system. This includes approval of what direction duct runs and any variables related to installation that are not called out in our specifications. Variance from our recommendations must be validated by an HVAC specialist as well as verification of air flow and speeds to insure proper ventilation. To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted information throughout this guide: IMPORTANT NOTE highlights information that is especially important. CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed. WARNING states a hazard that may cause serious injury or death if precautions are not followed. Wolf Ventilation 3 wolfappliance.com/specs Wolf Ventilation. Ventilation is an integral part of any kitchen. Proper ventilation provides a cleaner, healthier, more enjoyable cooking environment by removing moisture, odor and unhealthy by-products of combustion, including carbon monoxide. Proper ventilation is essential for maintaining a healthy indoor environment and minimizing airborne health risks. Ventilation can provide a dramatic focal point for your kitchen or it can be concealed for an integrated look. Wolf ventilation systems are precisely crafted for both function and design. Choosing the proper ventilation system is one of the most important decisions you can make when designing your kitchen. Wolf has ventilation products to satisfy all needs and preferences. When selecting a ventilation system, it is important to note that Wolf ventilation systems are divided into two categories: cooktop ventilation and pro ventilation. Cooktop ventilation. Pro ventilation. Selecting a Ventilation System 4 Selecting a Ventilation System For Wolf ranges and rangetops, a pro ventilation hood or hood liner should be used. A downdraft can be used with sealed burner rangetop models SRT304 and SRT366. An accessory trim kit is required for this installation. Contact your authorized Wolf dealer for details. COOKTOP OR PRO VENTILATION Wolf cooktop ventilation hoods can be used with Wolf induction, electric and gas cooktops and integrated modules. Wolf downdraft systems can be used with Wolf framed induction, framed electric and gas cooktops and some integrated modules. Downdrafts cannot be installed with unframed induction and unframed electric cooktops, and steamer and fryer modules. They are not recommended for use with the grill module. Wolf pro ventilation hoods and hood liners can be used with all Wolf cooking appliances. The chart below provides a reference of Wolf ventilation products typically used with Wolf cooking appliances. COOKTOP VENTILATION PRO VENTILATION CHIMNEY HOODS LOW-PROFILE HOODS DOWNDRAFT SYSTEMS WALL HOODS WALL CHIMNEY HOODS ISLAND HOODS HOOD LINERS Framed Induction Cooktops • • • • • • • Unframed Induction Cooktops • • • • • • Framed Electric Cooktops • • • • • • Unframed Electric Cooktops • • • • • • Gas Cooktops • • • • • • • CT15I/S, CT15E/S and IM15/S • • • • • • • IG15/S, IS15/S and IF15/S • • • • • • • • • • • • • • All Other Sealed Burner Rangetops • • • • Gas Ranges • • • • Gas Rangetops • • • • COOKTOPS • INTEGRATED MODULES RANGES AND RANGETOPS Dual Fuel Ranges SRT304 and SRT366 • Selecting a Ventilation System 5 wolfappliance.com/specs Selecting a Ventilation System UPDRAFT OR DOWNDRAFT HOOD MOUNTING HEIGHT The choice between updraft ventilation and downdraft ventilation will depend on several factors, most notably the cooking appliance being used as well as the type of installation and installation location. Updraft ventilation, or an overhead hood, will typically be a more effective ventilation option. Cooking vapors naturally rise, making it easier to collect and remove them from the cooking area. Proper mounting height is very important. If a ventilation hood is mounted too low, access to the cooking surface may be restricted. If a hood is mounted too high, performance may be compromised. Wolf downdraft systems provide another effective ventilation option. The telescopic downdraft chimney rises up from the countertop and draws cooking vapors away from the cooking surface. Downdraft ventilation is a great option in installations where an overhead hood is either not wanted or is not a viable option. WIDTH GUIDELINES For wall installations, the width of the hood should be at least as wide as the cooking surface. Where space is not restricted, a wider hood can be used to increase the capture area. Island and peninsula installations require a greater capture area. Island hoods should exceed the width of the cooking surface by a minimum of 3" (76) on each side. For downdraft ventilation systems, the width of the downdraft should match the width of the cooktop. For optimal performance, cooktop hoods should be mounted 24" (610) to 30" (762) from the bottom of the hood to the countertop. For optimal performance, pro hoods should be mounted 30" (762) to 36" (914) from the bottom of the hood to the countertop. Refer to individual specifications for each ventilation hood on pages 14–41. CEILING HEIGHT Before selecting a Wolf ventilation hood, check the installation site for adequate ceiling height, or any extra space that may remain after proper installation of the hood and cooking appliance. This can be determined by adding the floor-to-countertop height, plus the recommended hood mounting height (bottom of the hood to the countertop), plus the height of the hood. Refer to individual specifications for each ventilation hood on pages 14–41. Excess ceiling height can be filled using an accessory flue extension (available for some cooktops hoods) or a stainless steel duct cover (pro hoods). The space can also be adjusted by raising or lowering your hood within the specified mounting height for your hood. For additional ceiling height guidelines for cooktop wall and island hoods, refer to page 15. Selecting a Ventilation System 6 Selecting a Ventilation System COOKING STYLE INTERNAL, IN-LINE OR REMOTE BLOWER The appropriate airflow capacity is determined by the cooking space and cooking style. Greater exhaust capacity is required to handle moisture generated by boiling large pots of water or the grease and smoke from grilling or frying. Cooking with high heat or cooking aromatic foods may require additional CFM, and increasing the capture area with a hood that exceeds the cooking surface by 3" (76) on each side. With the exception of some cooktop low-profile hoods and some downdrafts, Wolf ventilation products are shipped without the blower assembly. An internal, in-line or remote blower must be selected to accommodate the Wolf cooking appliance. If the cooking surface is in an island or peninsula, a higher airflow capacity hood can provide better capture for cross currents, or if the hood needs to be mounted higher. Downdraft ventilation systems are also a good alternative. VENTILATION PERFORMANCE Ventilation performance is measured in cubic feet per minute, or CFM. The higher the CFM, the greater the amount of air that is evacuated through the ventilation system. CFM are based on the cooking appliance output. Wolf suggests 1 CFM per 100 Btu (.03 kW). The chart on page 10 provides CFM for all Wolf cooking appliances. The blower will vary in size, which is dictated by the cooking surface, the volume of air that needs to be moved and the length of the duct run. RECIRCULATING VENTILATION Recirculating ventilation units are installed on top of a ventilation hood with no ductwork required. Recirculating units recycle the air through a charcoal filter and return it to the kitchen. Wolf recirculating units are for use with cooktop low-profile hoods with an internal blower and some pro wall hood models. Recirculating units should not be used with ranges or rangetops that contain a charbroiler or griddle. Refer to specifications for recirculating ventilation on pages 42–43. IMPORTANT NOTE: This type of ventilation will not remove heat, moisture or combustion gases from the air. It will also be less effective in reducing odors and smoke. Selecting a Ventilation System 7 wolfappliance.com/specs Selecting a Ventilation System DUCTWORK CONSIDERATIONS ELECTRICAL REQUIREMENTS IMPORTANT NOTE: Unless used in a recirculating application, Wolf ventilation hoods and downdrafts must be vented to the outside. Use only rigid metal ducting. All Wolf ventilation products require a separate, grounded electrical supply. Refer to the electrical requirements for your specific ventilation product on pages 14–41. Locate the electrical supply within the shaded area shown in the installation illustration. Typically, wall-mounted ventilation hoods can be vertical or horizontal discharge, while wall chimney hoods, island hoods and hood liners are vertical discharge only. For some wall hoods, an accessory horizontal discharge kit is required. In a horizontal discharge application, additional framework may be needed to accommodate the remote blower. Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around floor joists and other obstacles. Depending on the specific installation, ductwork can run through the roof, external wall or eave. Ductwork through an eave requires an internal blower. Refer to individual specifications for each ventilation hood on pages 14–41. A straight, short duct run with a limited number of elbows and transitions will allow the hood or downdraft to perform most efficiently. Wolf ventilation hoods will operate most efficiently when ductwork does not exceed 50' (15 m) in length, 40' (12 m) for downdrafts. Refer to the chart on page 9 to calculate total duct length. IMPORTANT NOTE: Consult a qualified HVAC professional for specific installation and ductwork applications. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. CUSTOM HOOD APPLICATIONS A custom decorative hood, used with pro hood liners, can be created out of wood, plaster, tile or metal to match virtually any design theme. The shape of the decorative hood is not critical as long as the hood liner fits completely inside the hood. The decorative hood and liner must fit together at the bottom edge in both width and depth. The height of the hood does not have to match the height of the liner. Interior dimensions of the decorative hood must exceed exterior dimensions of the liner. Refer to specifications for pro hood liners on pages 40–41. Ventilation Made Easy 8 Ventilation Made Easy After choosing your ventilation hood or downdraft, follow this three-step process to determine your blower needs: Step 1) Determine the Duct Run Step 2) Determine the CFM Step 3) Select a Blower Assembly Step 1: Determine the Duct Run Check local codes. Consult a qualified HVAC professional to ensure that all local codes are followed. Always refer to installation instructions for your specific Wolf ventilation product. Minimize the duct run and number of elbows and transitions. The length of the duct run and number of elbows and transitions can have a significant effect on ventilation performance. Keep the duct run as short as possible and limit the number of elbows and transitions. Do not place elbows and transitions back-to-back. Whenever possible, include a minimum 15" (381) straight ducting between elbows and transitions. Elbows and transitions placed too close to each other will cause a decrease in ventilation performance. Use recommended duct sizes. Depending on the specific ventilation product, Wolf recommends 8" (203) or 10" (254) ducting. Smaller duct sizes will significantly reduce ventilation performance. Refer to individual specifications for each ventilation product on pages 14–41. Do not use flexible metal ducting. Flexible metal ducting will increase air resistance and is not recommended by the National Uniform Mechanical Code Standards. Do not use butt joints. Whenever possible, use male and female connections with the male end pointing in the direction of the airflow. Tightly tape joints to maximize ventilation performance. Cold weather installations. Cold weather installations may require an additional backdraft damper to minimize backward flow of cold air. It should be placed as close to the roof or wall cap as possible. All Wolf ventilation hoods, except low-profile wall hoods, come with a backdraft damper connected to the transition. Downdraft systems do not have a backdraft damper. High altitudes. Ventilation systems are less effective at altitudes above 5,000' (1524 m). At these altitudes, you should estimate a 20%–25% reduction in CFM performance. Solutions include using a higher CFM blower and increasing the duct size. Make-up air may be required. Most newer homes have tightly sealed doors and windows. Make-up air may be needed to replace the air removed by the ventilation system. Many heating and air conditioning systems provide make-up air. Opening a window or door can be an option but may be less effective. Consult a qualified HVAC professional for specific applications. Recirculating ventilation. Recirculating units recycle the air through a charcoal filter and return it to the kitchen. This type of ventilation will not remove heat, moisture or combustion gases from the air. It will also be less effective in reducing odors and smoke. Recirculating units should only be used in applications where ductwork to the outside is not an option, and only if local codes allow it. Refer to specifications for recirculating ventilation on pages 42–43. Ventilation Made Easy 9 wolfappliance.com/specs Step 1: Determine the Duct Run Determining the equivalent duct length. Determine the equivalent duct length for your installation using the equivalent duct lengths for commonly used ducting. Refer to the chart on the following page. The equivalent duct length is calculated as follows: 1) Compute the length of all straight ducting. 2) Compute the equivalent duct length of all elbows, transitions and caps. 3) Add equivalent lengths for all sections of the duct run. EQUIVALENT DUCT LENGTHS DUCTING EQUIVALENT LENGTH SIZE 1' (.3 m) STRAIGHT DUCTING 6" (152) round 4' (1.2 m) 8" (203) round 1' (.3 m) 10" (254) round .3' (.1 m) 3 1/4" (83) x 10" (152) 4' (1.2 m) 6" (152) round 24' (7.3 m) 8" (203) round 7' (2.1 m) 10" (254) round 3' (.9 m) 3 1/4" (83) x 10" (152) 12' (3.7 m) 6" (152) round 12' (3.7 m) 90° ELBOW 45° ELBOW 8" (203) round 4' (1.2 m) 10" (254) round 2' (.6 m) 3 1/4" (83) x 10" (152) 8' (2.4 m) 6" (152) round to 3 1/4" (83) x 10" (152) 5' (1.5 m) ROUND TO RECTANGULAR TRANSITION 8" (203) round to 3 1/4" (83) x 10" (152) 1' (.3 m) 3 1/4" (83) x 10" (152) to 6" (152) round 12' (3.7 m) 3 1/4" (83) x 10" (152) to 8" (203) round 16' (4.9 m) 6" (152) round to 8" (203) round 4' (1.2 m) 8" (203) round to 10" (254) round 1' (.3 m) 8" (203) round to 6" (152) round 12' (3.7 m) 10" (254) round to 8" (203) round 3' (.9 m) 6" (152) round 60' (18.3 m) ROUND TO ROUND TRANSITION ROOF CAP OR WALL CAP 8" (203) round 20' (6.1 m) 10" (254) round 9' (2.7 m) 3 1/4" (83) x 10" (152) 60' (18.3 m) TOTAL QUANTITY TOTAL Ventilation Made Easy 10 Step 2: Determine the CFM The chart below provides CFM specific to the cooking appliance and ventilation system used. CFM are based on the cooking appliance output. Wolf suggests 1 CFM per 100 Btu (.03 kW). Additional CFM may be required for long duct runs and ranges or rangetops with a charbroiler or griddle. When determining the proper CFM for your installation, take into consideration the equivalent duct length calculated on the previous page. IMPORTANT NOTE: Consult a qualified HVAC professional for specific applications. IMPORTANT NOTE: Specifing a blower with less CFM than listed in the chart below will result in decreased airflow and performance. WOLF PRODUCT CFM COOKTOP HOODS DOWNDRAFTS PRO HOODS CFM CFM CFM CT15I CT15E CT15G IG15* IS15* IF15* IM15 215 150 215 CT30I CT30IU* CT30E CT30EU* CT30G 450 350 500 CT36I CT36IU* CT36E CT36EU* CT36G 600 500 500 MODEL COOKTOPS AND MODULES DUAL FUEL RANGES DF304 500 DF366 DF364C DF364G 900 DF486C DF486G DF484CG DF484DG DF484F 1100 DF606DG DF606F DF606CG DF604CF DF604GF 1500 SEALED BURNER RANGETOPS SRT304 500 500 SRT366 500 900 SRT364C SRT364G 900 SRT486C SRT486G SRT484CG SRT484DG SRT484F 900 GAS RANGES R304 500 R366 R364C R364G 900 R488 R486C R486G R484CG R484DG R484F 1100 R606DG R606F R606CG 1500 GAS RANGETOPS RT366 RT364C RT364G RT362F 900 RT488 RT486C RT486G RT484CG RT484DG RT484F 1100 *Downdraft systems are not recommended for use with these models. CFM are based the cooking appliance output. Wolf suggests 1 CFM per 100 Btu (.03 kW). Additional CFM may be required for long duct runs or ranges and rangetops with a charbroiler or griddle. Ventilation Made Easy 11 wolfappliance.com/specs Step 3: Select a Blower WOLF BLOWER ASSEMBLIES IN-LINE BLOWERS With the exception of some cooktop low-profile hoods and some downdrafts, Wolf ventilation products are shipped without the blower assembly. An internal, in-line or remote blower must be selected to accommodate the Wolf cooking appliance. Wolf blower assemblies are available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. In-line blowers are mounted between the hood and the exterior of the home. Ductwork runs from the hood and connects to the blower. More ductwork is attached to the other side of the blower and runs to the exterior of the home. This is a great option for those who do not want the blower mounted inside the hood but cannot, or prefer not to mount a remote blower on the exterior of the home. IMPORTANT NOTE: Wolf ventilation products must be installed only with a Wolf blower. The chart on the following pages provides blower options for all cooktop and pro ventilation products. Installation instructions shipped with each Wolf blower assembly provide detailed specifications. INTERNAL BLOWERS Internal blowers are mounted inside the hood canopy or downdraft blower box and provide the least disruption to the exterior of the home. Internal blowers are available for all Wolf cooktop and pro ventilation products. Refer to specifications for Wolf internal blowers on pages 44–48. In-line blowers are available for all Wolf cooktop and pro ventilation products. Refer to specifications for Wolf in-line blowers on pages 49–50 with additional planning information on pages 58–59. REMOTE BLOWERS Remote blowers can be mounted on the roof or, in some cases, on an exterior wall. A remote-mounted blower will minimize the amount of blower noise but will not eliminate the noise completely. Some blower noise is considered normal while the blower is operational. If noise is a concern, a remote blower is recommended. To reduce noise further for remote blower applications, an attenuator may be necessary. Remote blowers are available for all Wolf cooktop and pro ventilation products. Refer to specifications for Wolf remote blowers on pages 51–57 with additional planning information on pages 60–62. Ventilation Made Easy 12 Step 3: Select a Blower INTERNAL CFM BLOWER 300* 450* 500 600 900 1200 814419 814420 810991 814421 814422 814423 COOKTOP HOODS CTWH30 • • • CTWH36 IH4227 • • • • • • COOKTOP LOW-PROFILE HOODS CTEWH36 CTEWH45 DOWNDRAFTS DD30R DD36R DD45R PRO LOW-PROFILE WALL HOODS PW302210 PW362210 • PW422210 PW482210 PRO 24" (610) WALL HOODS PW302418 PW362418 PW422418 • • PW482418 PW542418 • • PW602418 PW662418 • • PW302718 PW362718 PW422718 • • PW482718 PW542718 • • PW602718 PW662718 • • PWC362418 PWC422418 • • PWC482418 PWC542418 • • PI363418 PI423418 • • PI543418 • • PI663418 • • PL342212 PL402212 • • • • PL462212 • • • • • PL522212 • • • • PL582212 • • • • • PRO 27" (686) WALL HOODS • • • • • PRO WALL CHIMNEY HOODS • • • • • • • • PRO ISLAND HOODS • • PRO HOOD LINERS *For make-up air restricted applications. Capture and performance may be reduced. • Ventilation Made Easy 13 wolfappliance.com/specs Step 3: Select a Blower IN-LINE CFM REMOTE 600 1100 600 900 1200 1500 808331 808332 801640 801641 801642 804701 CTWH30 • • • • • • CTWH36 IH4227 • • • • • • • • • BLOWER COOKTOP HOODS COOKTOP LOW-PROFILE HOODS CTEWH36 CTEWH45 • • DOWNDRAFTS DD30R DD36R DD45R • PRO LOW-PROFILE WALL HOODS PW302210 PW362210 • • • PW422210 PW482210 • • • PRO 24" (610) WALL HOODS PW302418 • • PW362418 PW422418 PW482418 PW542418 • PW602418 PW662418 • • • • • • • • • • PRO 27" (686) WALL HOODS PW302718 • • PW362718 PW422718 PW482718 PW542718 • PW602718 PW662718 • • • • • • • • • • PRO WALL CHIMNEY HOODS PWC362418 PWC422418 • • • • PWC482418 PWC542418 • • • • PI363418 PI423418 • • • • PI543418 • • • • PI663418 • • • PRO ISLAND HOODS PRO HOOD LINERS PL342212 PL402212 • • • • PL462212 • • • • PL522212 • • • • PL582212 • • • • Wolf Cooktop Ventilation 14 Wolf Cooktop Ventilation COOKTOP CHIMNEY HOODS DOWNDRAFT SYSTEMS Wolf cooktop chimney hoods are crafted of seamless stainless steel. Chimney wall and island hoods have a telescopic flue which allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension for 10' (3 m) ceilings is available as a sales accessory. Wolf downdraft ventilation systems are crafted of stainless steel. Downdrafts are available with an internal blower, or some models have in-line and remote blower options. Wolf cooktop chimney hoods can be used with all Wolf cooktops and integrated modules. COOKTOP LOW-PROFILE HOODS Wolf cooktop low-profile hoods are crafted of stainless steel with a black glass control panel. Low-profile wall and island hoods have a telescopic chimney flue which allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. Wall and island hoods are available with an internal blower, or some wall hood models have in-line and remote blower options. Wolf downdraft systems can be used with Wolf framed induction, framed electric and gas cooktops and some integrated modules. A downdraft can be used with sealed burner rangetop models SRT304 and SRT366. An accessory trim kit is required for this installation. Contact your authorized Wolf dealer for details. IMPORTANT NOTE: Wolf downdraft systems cannot be installed with unframed induction and unframed electric cooktops, and steamer and fryer modules. They are not recommended for use with the grill module. Refer to specifications for individual cooktop hoods and downdraft systems on the following pages. Wolf cooktop low-profile hoods can be used with all Wolf cooktops and integrated modules. Downdraft systems. Cooktop chimney hoods. Cooktop low-profile hoods. Cooktop Ventilation Widths WIDTH Chimney Wall Hoods 30" (762) 36" (914) • • • • Chimney Island Hoods Low-Profile Wall Hoods 45" (1143) • Low-Profile Island Hoods Downdrafts 42" (1067) • • • • • 48" (1219) 54" (1372) 60" (1524) 66" (1676) Wolf Cooktop Ventilation 15 wolfappliance.com/specs Wolf Cooktop Ventilation Hoods HOOD PLACEMENT CALCULATE CHIMNEY FLUE HEIGHT Installation of the cooktop wall or island hood should be 24" (610) to 30" (762) from the bottom of the hood to the countertop. To determine placement of the cooktop hood, you must calculate the height of the telescopic chimney flue. The minimum and maximum flue extension for each cooktop hood is listed in the charts below. A) Height from finished floor to finished ceiling. 8' (2.4 m) or 9' (2.7 m) ceilings are typical. IMPORTANT NOTE: Both sections of the telescopic chimney flue must be installed in order for the chimney to be lifted for service. B) Height from finished floor to countertop. A 36" (914) countertop height is standard. C) Hood mounting height (bottom of hood to countertop). Dimension C must be between 24" (610) and 30" (762). 8' (2.4 m) ceilings may not allow the maximum 30" (762) hood mounting height. D) Calculate chimney flue height: D = A – (B + C). Dimension D must be between the minimum and maximum flue extension listed in the charts. Refer to the illustration below. Cooktop Chimney Hoods FLUE EXTENSION MINIMUM MAXIMUM CTWH30 30 1/2" (775) 48 1/2" (1232) CTWH36 32 5/8" 50 7/8" (1292) IH4227 33 1/2" (851) (829) 47" (1194) D Cooktop Low-Profile Hoods FLUE EXTENSION MINIMUM MAXIMUM CTEWH30I 29 1/8" (740) 41 1/2" (1054) CTEWH36(I) 29 1/8" (740) 41 1/2" (1054) CTEWH45(I) 29 1/8" (740) 41 1/2" (1054) CTEIH42I 28 1/4" (718) 41 1/2" (1054) A MINIMUM FLUE EXTENSION C B Cooktop hood placement. Wolf Cooktop Ventilation 16 Cooktop Chimney Wall Hood Model Options MODEL WIDTH WEIGHT CTWH30 30" (762) 85 lbs (39 kg) CTWH36 35 1/2" 100 lbs (45 kg) (902) HEIGHT 21" WIDTH (533) FEATURES Specifications • Heavy-duty, stainless steel seamless construction. COOKTOP VENTILATION • Internal, in-line and remote blower options. Installation Type Wall • Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings. Exterior Finish Stainless Steel Front-mounted controls with LED indicator and threespeed blower control. Widths 30" (762) and 35 1/2" (902) Height (CTWH30) 6 7/8" (175) (CTWH36) 9 1/4" (235) Depth 21" (533) Telescoping Height (CTWH30) 30 1/2" (775)— 48 1/2" (1232) (CTWH36) 32 5/8" (829)— 50 7/8" (1292) • • Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed. • Halogen lighting with three settings. • Delay-off feature to automatically turn unit off. Installation Height • Filter clean timer lets you know when filters need cleaning. 24" (610) to 30" (762) bottom of hood to countertop Electrical Supply 120 V AC, 60 Hz, 15 amp dedicated circuit • Stainless steel filter cover with dishwasher-safe aluminum mesh filter. Halogen Bulbs Two or three T4, 12 V, 20 W bulbs (included) • Transition with backdraft damper. Discharge Vertical Duct Size 8" (203) Round ACCESSORIES • Internal, in-line and remote blowers (refer to chart below). • Flue extension to accommodate 10' (3 m) ceilings. • 30" (762) high stainless steel wall shield. • 8" (203) to 10" (254) round transition. Blower Options CFM INTERNAL 300* 450* 500 600 CTWH30 • • • CTWH36 • • • IN-LINE 900 • *For make-up air restricted applications. Capture and performance may be reduced. 1200 REMOTE 600 1100 600 900 1200 1500 • • • • • • • • • • • • Wolf Cooktop Ventilation 17 wolfappliance.com/specs Cooktop Chimney Wall Hood INSTALLATION DUCTWORK INSTALLATION THROUGH ROOF 18" (457) LOCATE ELECTRICAL WITHIN SHADED AREA 9" (229) E 6" 301/2" (775) TO 48 1/2" (1232) 19 1/8" (486) OR (152) 32 5/8" (829) TO 50 7/8" (1292) 4" (102) 6 7/8" (175) TELESCOPING HOOD HEIGHT OR 12" (305) 91/4" (235) 30" (762) OR 35 1/2" (902) 21" (535) HOOD DEPTH HOOD WIDTH 24" (610) TO 30" (762) BOTTOM OF HOOD TO COUNTERTOP NOTE: 8' (2.4 m) ceilings can not accommodate 30" (762) from bottom of hood to countertop. Based on 36" (914) countertop height, an 8' (2.4 m) ceiling will allow for a maximum 29 1/2" (749) for CTWH30 and 27 1/4" (692) for CTWH36, from bottom of hood to countertop. DUCTWORK INSTALLATION THROUGH WALL Wolf Cooktop Ventilation 18 Cooktop Chimney Island Hood Model Options MODEL WIDTH WEIGHT IH4227 42" (1067) 110 lbs (50 kg) 9 1/4" (235) 27" (686) 42" (1067) FEATURES Specifications • Heavy-duty, stainless steel seamless construction. COOKTOP VENTILATION • Internal, in-line and remote blower options. Installation Type Island • Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings. Exterior Finish Stainless Steel Front-mounted controls with LED indicator and threespeed blower control. Width 42" (1067) Height 9 1/4" (235) Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed. Depth 27" (686) Telescoping Height 33 1/2" (851) to 47" (1194) • Halogen lighting with three settings. Installation Height 24" (610) to 30" (762) bottom of hood to countertop • Delay-off feature to automatically turn unit off. Electrical Supply • Filter clean timer lets you know when filters need cleaning. 120 V AC, 60 Hz, 15 amp dedicated circuit Halogen Bulbs Stainless steel filter cover with dishwasher-safe aluminum mesh filter. Four T4, 12 V, 20 W bulbs (included) Discharge Vertical Duct Size 8" (203) Round • • • • Transition with backdraft damper. ACCESSORIES • Internal, in-line and remote blowers (refer to chart below). • Flue extension to accommodate 10' (3 m) ceilings. • 8" (203) to 10" (254) round transition. Blower Options CFM IH4227 INTERNAL 300* 450* • • 500 IN-LINE 600 900 • • *For make-up air restricted applications. Capture and performance may be reduced. 1200 REMOTE 600 1100 600 900 1200 1500 • • • • • • Wolf Cooktop Ventilation 19 wolfappliance.com/specs Cooktop Chimney Island Hood INSTALLATION DUCTWORK INSTALLATION THROUGH ROOF LOCATE ELECTRICAL THROUGH TOP OF HOOD 18" (457) DUCTWORK INSTALLATION THROUGH EAVE— INTERNAL BLOWER 19 1/4" (489) 9 1/4" 33 1/2" (851) TO 47" (1194) TELESCOPING HOOD HEIGHT 12" (305) (235) 27" (686) HOOD DEPTH 42" (1067) HOOD WIDTH 24" (610) TO 30" (762) BOTTOM OF HOOD TO COUNTERTOP Wolf Cooktop Ventilation 20 Cooktop Low-Profile Wall Hood Model Options 3 1/8" MODEL WIDTH WEIGHT CTEWH30I* 30" (762) 53 lbs (24 kg) CTEWH36 36" (914) 51 lbs (23 kg) CTEWH36I* 36" (914) 57 lbs (26 kg) CTEWH45 45" (1143) 55 lbs (25 kg) CTEWH45I* 45" (1143) 62 lbs (28 kg) *Internal blower included. (79) 17 3/4" WIDTH (451) FEATURES Specifications • Heavy-duty, stainless steel seamless construction. COOKTOP VENTILATION • Internal, in-line and remote blower options. Installation Type Wall • Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings. Exterior Finish Stainless Steel • Front-mounted electronic controls with digital indicator and four-speed blower control. Widths 30" (762), 36" (914) and 45" (1143) Height 3 1/8" (79) Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed. Depth 17 3/4" (451) Telescoping Height 29 1/8" (740) to 41 1/2" (1054) • Halogen lighting with three settings. Installation Height 24" (610) to 30" (762) bottom of hood to countertop • Delay-off feature to automatically turn unit off. Electrical Supply • Filter clean indicator. 120 V AC, 60 Hz, 15 amp dedicated circuit • Stainless steel filter cover with dishwasher-safe aluminum mesh filter. Halogen Bulbs Four T4, 12 V, 20 W bulbs (included) • Transition with backdraft damper. • Discharge Vertical Duct Size 6" (152) Round ACCESSORIES • In-line and remote blowers for CTEWH36 and CTEWH45 (refer to chart below). • 30" (762) high stainless steel wall shield. • Recirculating kit and filter for non-ducted applications (internal blower models). Blower Options CFM CTEWH30I CTEWH36I CTEWH45I CTEWH36 CTEWH45 INTERNAL 300 450 500 600 IN-LINE 900 1200 600 1100 REMOTE 600 Included • • 900 1200 1500 Wolf Cooktop Ventilation 21 wolfappliance.com/specs Cooktop Low-Profile Wall Hood INSTALLATION DUCTWORK INSTALLATION THROUGH ROOF 9 7/8" 10 7/8" (251) (276) E LOCATE ELECTRICAL WITHIN SHADED AREA 5" (127) 15" (381) 8' (2.4 m) TO 9' (2.7 m) CEILING HEIGHT 29 1/8" (740) TO 411/2" (1054) TELESCOPING HOOD HEIGHT DUCTWORK INSTALLATION THROUGH WALL 1 20 /8" (511) 3 1/8" (79) 30" (762), 36" (914) OR 45" (1143) 17 3/4" (451) HOOD DEPTH HOOD WIDTH 24" (610) TO 30" (762) BOTTOM OF HOOD TO COUNTERTOP NOTE: For non-ducted applications with a recirculating kit, the telescoping hood height is 31" (788) to 48 3/4" (1238). Wolf Cooktop Ventilation 22 Cooktop Low-Profile Island Hood Model Options MODEL WIDTH WEIGHT CTEIH42I* 42" (1067) 92 lbs (42 kg) *Internal blower included. 3 1/8" (79) 21 5/8" (459) 42" (1067) FEATURES Specifications • Heavy-duty, stainless steel seamless construction. COOKTOP VENTILATION • Internal blower included. Installation Type Island • Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings. Exterior Finish Stainless Steel • Front-mounted electronic controls with digital indicator and four-speed blower control. Width 42" (1067) Height 3 1/8" (79) Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed. Depth 21 5/8" (459) Telescoping Height 28 3/8" (721) to 40" (1016) • Halogen lighting with three settings. Installation Height 24" (610) to 30" (762) bottom of hood to countertop • Delay-off feature to automatically turn unit off. Electrical Supply • Filter clean indicator. 120 V AC, 60 Hz, 15 amp dedicated circuit • Stainless steel filter cover with dishwasher-safe aluminum mesh filter. Halogen Bulbs Four T4, 12 V, 20 W bulbs (included) • Transition with backdraft damper. • Discharge Vertical Duct Size 6" (152) Round ACCESSORIES • Recirculating kit and filter for non-ducted applications. Blower Options CFM CTEIH42I INTERNAL 300 450 500 Included 600 IN-LINE 900 1200 600 1100 REMOTE 600 900 1200 1500 Wolf Cooktop Ventilation 23 wolfappliance.com/specs Cooktop Low-Profile Island Hood INSTALLATION DUCTWORK INSTALLATION THROUGH ROOF LOCATE ELECTRICAL THROUGH TOP OF HOOD 11 3/4" (298) 22 7/8" (581) 28 3/8" (721) TO 40" (1016) TELESCOPING HOOD HEIGHT DUCTWORK INSTALLATION THROUGH EAVE— INTERNAL BLOWER 9 7/8" (251) 3 1/8" (79) 21 5/8" (549) HOOD DEPTH 42" (1067) HOOD WIDTH 24" (610) TO 30" (762) BOTTOM OF HOOD TO COUNTERTOP 8' (2.4 m) TO 9' (2.7 m) CEILING HEIGHT NOTE: For non-ducted applications with a recirculating kit, the telescoping hood height is 30 3/4" (781) to 40" (1016). Wolf Cooktop Ventilation 24 Downdraft Ventilation System Model Options 9 1/8" (232) WIDTH 2 3/8" (60) MODEL WIDTH WEIGHT DD30I* 30" (762) 90 lbs (41 kg) DD30R 30" (762) 75 lbs (34 kg) DD36I* 36" (914) 95 lbs (43 kg) DD36R 36" (914) 80 lbs (36 kg) DD45I* 45 1/2" 100 lbs (45 kg) DD45R 45 1/2" (1156) (1156) 85 lbs (39 kg) *Internal blower included. FEATURES Specifications • Crafted of heavy-duty stainless steel. COOKTOP VENTILATION • Downdraft chimney lowers beneath countertop when not in use. Installation Type Downdraft Exterior Finish Stainless Steel Stainless steel top trim and remote-mounted control module with LED indicators. Top Trim Widths 30" (762), 36" (914) and 45 1/2" (1156) Chimney Widths 26 1/4" (667), 32 1/4" (819) and 41 1/4" (1048) Height 9 1/8" (232) above countertop Top Trim Depth 2 3/8" (60) Chimney Depth 1 1/2" (38) Electrical Supply 120 V AC, 60 Hz, 15 amp dedicated circuit Power Cord 2 1/2' (.8 m) 3-prong • • Three-speed blower control. • Delay-off feature to automatically turn unit off. • Filter clean timer lets you know when filters need cleaning. • Dishwasher-safe aluminum mesh filters with stainless steel filter covers. ACCESSORIES • In-line and remote blowers for DD30R, DD36R and DD45R (refer to chart below). • Support bracket for installation with two integrated modules (DD30). • Trim kit for installation with sealed burner rangetop (DD30 and DD36). • Transitions to round ductwork. Blower Options CFM Adjustable ( I ) 31/4" (83) x 10" (254) (R) 31/4" (83) x 14" (356) INTERNAL 300* 450* DD30I DD36I DD45I DD30R DD36R DD45R Discharge Duct Size 500 600 IN-LINE 900 1200 600 REMOTE 1100 600 900 1200 1500 • • • Included • • *For make-up air restricted applications. Capture and performance may be reduced. • Wolf Cooktop Ventilation 25 wolfappliance.com/specs Downdraft Ventilation System INSTALLATION WITH COOKTOP INSTALLATION WITH SEALED BURNER RANGETOP 2 3/4" (70) 2 3/4" (70) 27" (686), 33" (838) OR 42" (1067) 27" (686) OR 33" (838) DOWNDRAFT CUT-OUT DOWNDRAFT CUT-OUT 25 1/8" (638) min FLAT COUNTERTOP 3" (76) min TO CONTROL MODULE 30" (762) rec 3" (76) min TO CONTROL MODULE 19 1/4" FLAT COUNTERTOP (489) COOKTOP CUT-OUT WIDTH 30" (762) OR 36" (914) WIDTH OF RANGETOP 24" (610) min* 21/2" (64) min COUNTERTOP CUT-OUT (TOP VIEW) 21/2" (64) min COUNTERTOP CUT-OUT (TOP VIEW) 21/2" (64) min 25 1/8" (638) min FLAT COUNTERTOP EDGE OF COOKTOP TO WALL 30" (762) rec FLAT COUNTERTOP EDGE OF RANGETOP TO WALL 7 1/2" 7 11/16" (197) 19" (483) (191) PLATFORM DEPTH 29 5/16" 29 5/16" (745) (745) 7 1/8" 7 1/8" (181) (181) 27 1/4" (692) min CABINET DEPTH 24" min (610) CABINET DEPTH SIDE VIEW SIDE VIEW *Additional depth may be required if rangetop is to be installed flush with cabinet face. NOTE: To install a downdraft with a Wolf cooktop, you must allow for a minimum 251/8" (638) flat counter space from front to back. A countertop with a raised lip or backsplash may not allow enough space for proper installation. Location of the electrical outlet must be within reach of the power cord which is located midway, top and bottom, on the right side of the downdraft. Unless oversized cabinets are used, the outlet cannot be located on the back wall of the cabinet, but may be placed in adjacent cabinetry. Installation of the remote-mounted control module must be within 10' (3 m) of the downdraft assembly and a minimum of 4" (102) from the outer edge of cooktop element or burner. Wolf Cooktop Ventilation 26 Downdraft Ventilation System SIDE DISCHARGE BOTTOM DISCHARGE COUNTERTOP CUT-OUT COUNTERTOP CUT-OUT ADJUSTMENT B B A RIGHT DISCHARGE LOCATION ADJUSTMENT A C C LEFT DISCHARGE LOCATION BOTTOM DISCHARGE LOCATION DISCHARGE CUT-OUT: DISCHARGE CUT-OUT: 101/4" (260) x 31/2" (89) INTERNAL BLOWER 141/4" (362) x 31/2" (89) IN-LINE OR REMOTE 101/4" (260) x 31/2" (89) INTERNAL BLOWER 141/4" (362) x 31/2" (89) IN-LINE OR REMOTE Side Discharge BLOWER Bottom Discharge INTERNAL IN-LINE / REMOTE BLOWER INTERNAL IN-LINE / REMOTE Dimension A 22 1/8" 19" (483) Adjustment A N/A 5" (127) MAX Dimension B 16 3/8" (416) 211/2" (546) Adjustment B 1" (25) TO 7" (178) 2 1/2" (165) MAX Dimension C 5 1/2" (140) 4 1/4" (108) Dimension C 5 1/2" (140) 4 1/4" (108) (562) NOTE: Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around floor joists and other obstacles. Three different discharge locations (left side, right side or bottom) allow side-to-side adjustment for accurate alignment of ductwork. Wolf Cooktop Ventilation 27 wolfappliance.com/specs Downdraft Ventilation System DUCTWORK OPTIONS 10" (254) REMOTE ROUND DUCT BLOWER WALL CAP 12" (305) MIN TO GROUND Internal blower through wall. Remote blower through roof. REMOTE BLOWER 10" (254) ROUND DUCT WALL CAP 12" (305) MIN TO GROUND 12" (305) MIN TO GROUND Internal blower through wall. Remote blower through wall. Wolf Pro Ventilation 28 Wolf Pro Ventilation Wolf pro ventilation is available in a wide variety of styles and sizes to meet virtually any application, including hood liners for installation with a custom decorative hood. Wolf pro ventilation hoods and hood liners can be used with all Wolf cooking appliances. Refer to specifications for individual pro ventilation products on the following pages. Installation of pro hoods and hood liners should be 30" (762) to 36" (914) from the bottom of the hood to the countertop. PRO WALL HOODS Pro wall ventilation hoods are crafted of seamless stainless steel and available in three styles. Low-profile hoods are 22" (559) deep and 10" (254) high, while the pro 24" (610) and 27" (686) deep wall hoods are 18" (381) high. All three styles come in a variety of widths. Refer to the chart on the following page. Pro 27" (686) deep wall hoods feature heat lamps. PRO ISLAND HOODS Pro island hoods are crafted of seamless stainless steel. The width of the island hood should exceed the width of the cooking surface by a minimum of 3" (76) on each side. PRO HOOD LINERS Pro ventilation hood liners are available to accommodate custom decorative hoods. The custom decorative hood can be created out of wood, plaster, tile or metal to match virtually any design theme. The shape of the decorative hood is not critical as long as the hood liner fits completely inside the hood. The decorative hood and liner must fit together at the bottom edge in both width and depth. The height of the hood does not have to match the height of the liner. Interior dimensions of the decorative hood must exceed exterior dimensions of the liner. IMPORTANT NOTE: For optimal performance, a pro 27" (686) deep wall hood should be used with ranges and rangetops that contain a charbroiler or griddle. PRO WALL CHIMNEY HOODS Pro wall chimney hoods are crafted of seamless stainless steel. Optional duct covers in a variety of heights are available to complete the chimney design. Pro island hoods. Pro wall hoods. Pro wall chimney hoods. Pro hood liners. Wolf Pro Ventilation 29 wolfappliance.com/specs Wolf Pro Ventilation Pro Ventilation Widths WIDTH 30" (762) 36" (914) 42" (1067) Low-Profile Wall Hoods • • • 45" (1143) 48" (1219) • 54" (1372) 60" (1524) 66" (1676) 24" Deep Wall Hoods • • • 27" Deep Wall Hoods • • • • • • • • • • Wall Chimney Hoods • • • • • Island Hoods • • Hood Liners • • • • • • • Wolf Pro Ventilation 30 Pro Low-Profile Wall Hood Model Options 10" (254) 22" WIDTH (559) FEATURES MODEL WIDTH WEIGHT PW302210 30" (762) 39 lbs (18 kg) PW362210 36" (914) 44 lbs (20 kg) PW422210 42" (1067) 50 lbs (23 kg) PW482210 48" (1219) 55 lbs (25 kg) Specifications • Heavy-duty, brushed stainless steel exterior with enclosed liner. PRO VENTILATION Installation Type Wall • Internal, in-line and remote blower options. Exterior Finish Stainless Steel • Welded seams, hemmed edges and hand-finished craftsmanship. Widths 30" (762), 36" (914), 42" (1067) and 48" (1219) • Recessed easy-access controls. Height 10" (254) Depth 22" (559) Installation Height 30" (762) to 36" (914) bottom of hood to countertop Electrical Supply 120 V AC, 60 Hz, 15 amp dedicated circuit Halogen Bulbs Two or three 50 W, 120 V par 20 bulbs (included) • Infinite-speed blower control. • Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed. • Halogen lighting with two settings. • Removable, dishwasher-safe stainless steel baffle filters. Discharge Vertical or Horizontal ACCESSORIES Duct Size 10" (254) Round • Internal, in-line and remote blowers (refer to chart below). Transition • 38" (965) high stainless steel backsplash with or without warming racks. 3 1/4" (83) x 14" (356) cut-out (transition included with internal blower) • 6" (152), 12" (305), 18" (457), 24" (610) and 30" (762) high stainless steel duct covers. • Recirculating kit and filter for non-ducted applications— 30" (762) and 36" (914) wide models with internal blower. Blower Options CFM PW302210 PW362210 PW422210 PW482210 INTERNAL 300 450 500 • 600 IN-LINE 900 1200 600 1100 REMOTE 600 900 • • • • • • 1200 1500 Wolf Pro Ventilation 31 wolfappliance.com/specs Pro Low-Profile Wall Hood INSTALLATION DUCTWORK INSTALLATION THROUGH ROOF LOCATE ELECTRICAL WITHIN SHADED AREA 6" (152) E 5" (127) 12" 10" (254) HOOD HEIGHT (305) 4" (102) 30" (762), 36" (914) 42" (1067) OR 48" (1219) 22" (559) HOOD DEPTH HOOD WIDTH 30" (762) TO 36" (914) BOTTOM OF HOOD TO COUNTERTOP NOTE: Pro low-profile wall hoods come standard with vertical or horizontal discharge. Wolf Pro Ventilation 32 Pro 24" Deep Wall Hood Model Options 18" (457) 24" WIDTH (610) MODEL WIDTH WEIGHT PW302418 30" (762) 67 lbs (30 kg) PW362418 36" (914) 78 lbs (35 kg) PW422418 42" (1067) 86 lbs (39 kg) PW482418 48" (1219) 94 lbs (43 kg) PW542418 54" (1372) 106 lbs (48 kg) PW602418 60" (1524) 116 lbs (53 kg) PW662418 66" (1676) 126 lbs (57 kg) FEATURES • Heavy-duty, brushed stainless steel exterior with enclosed liner. PRO VENTILATION • Internal, in-line and remote blower options. Installation Type Wall • Hand-finished, welded seams and hemmed edges. Exterior Finish Stainless Steel • Recessed easy-access controls. Widths • Infinite-speed blower control. 30" (762), 36" (914), 42" (1067) 48" (1219), 54" (1372), 60" (1524) and 66" (1676) • Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed. Height 18" (457) Depth 24" (610) • Halogen lighting with two settings. Installation Height • Removable, dishwasher-safe stainless steel baffle filters. 30" (762) to 36" (914) bottom of hood to countertop • Transition with backdraft damper. Electrical Supply 120 V AC, 60 Hz, 15 amp dedicated circuit • Horizontal discharge with accessory kit. Halogen Bulbs Two or three 50 W, 120 V par 20 bulbs (included) Discharge Vertical or Horizontal (requires horizontal discharge kit) Specifications ACCESSORIES • Internal, in-line and remote blowers (refer to chart below). Duct Size 10" (254) Round • 38" (965) high stainless steel backsplash with or without warming racks. Transition Rectangle to 10" (254) round, 9" (229) height (included) • 6" (152), 12" (305), 18" (457), 24" (610) and 30" (762) high stainless steel duct covers. • Horizontal discharge kit. • Recirculating kit and filter for non-ducted applications— 30" (762) and 36" (914) wide models with internal blower. Blower Options CFM INTERNAL 500 IN-LINE 300* 450* 600 900 PW302418 • • • • PW362418 • • • • PW422418 • • • • PW482418 PW542418 • • PW602418 PW662418 • • • *For make-up air restricted applications. Capture and performance may be reduced. 1200 REMOTE 600 1100 600 900 1200 • • • • • 1500 • • • • • • • • • • • • • • • • • • Wolf Pro Ventilation 33 wolfappliance.com/specs Pro 24" Deep Wall Hood INSTALLATION DUCTWORK INSTALLATION THROUGH ROOF LOCATE ELECTRICAL WITHIN SHADED AREA 6" (152) E 5" 12" (127) (305) 18" (457) HOOD HEIGHT 4" (102) 30" (762), 36" (914), 42" (1067) 48" (1219), 54" (1372) 60" (1524) OR 66" (1676) HOOD WIDTH 24" (610) HOOD DEPTH 30" (762) TO 36" (914) BOTTOM OF HOOD TO COUNTERTOP NOTE: Alternative horizontal discharge requires accessory kit. Refer to instructions provided with kit for detailed specifications. Wolf Pro Ventilation 34 Pro 27" Deep Wall Hood Model Options 18" (457) 27" WIDTH (686) FEATURES MODEL WIDTH WEIGHT PW302718 30" (762) 69 lbs (31 kg) PW362718 36" (914) 80 lbs (36 kg) PW422718 42" (1067) 88 lbs (40 kg) PW482718 48" (1219) 96 lbs (44 kg) PW542718 54" (1372) 108 lbs (49 kg) PW602718 60" (1524) 118 lbs (54 kg) PW662718 66" (1676) 128 lbs (58 kg) Specifications • Heavy-duty, brushed stainless steel exterior with enclosed liner. PRO VENTILATION Installation Type Wall • Internal, in-line and remote blower options. Exterior Finish Stainless Steel • Hand-finished, welded seams and hemmed edges. Widths • Recessed easy-access controls. 30" (762), 36" (914), 42" (1067) 48" (1219), 54" (1372), 60" (1524) and 66" (1676) • Infinite-speed blower control. Height 18" (457) • Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed. Depth 27" (686) Installation Height 30" (762) to 36" (914) bottom of hood to countertop Electrical Supply 120 V AC, 60 Hz, 15 amp dedicated circuit Halogen Bulbs Two or three 50 W, 120 V par 20 bulbs (included) Heat Lamp Bulbs Two R40 250 W, 120 V, 60 Hz infrared bulbs (not included) Discharge Vertical or Horizontal (requires horizontal discharge kit) • Halogen lighting with two settings. • Heat lamp receptacles (bulbs not included). • Removable, dishwasher-safe stainless steel baffle filters. • Transition with backdraft damper. • Horizontal discharge with accessory kit. ACCESSORIES • Internal, in-line and remote blowers (refer to chart below). • 38" (965) high stainless steel backsplash with or without warming racks. • 6" (152), 12" (305), 18" (457), 24" (610) and 30" (762) high stainless steel duct covers. • Horizontal discharge kit. Blower Options CFM Duct Size 10" (254) Round Transition Rectangle to 10" (254) round, 9" (229) height (included) INTERNAL 500 IN-LINE 300* 450* 600 900 PW302718 • • • • PW362718 • • • • PW422718 • • • • PW482718 PW542718 • • PW602718 PW662718 • • • *For make-up air restricted applications. Capture and performance may be reduced. 1200 REMOTE 600 1100 600 900 1200 • • • • • 1500 • • • • • • • • • • • • • • • • • • Wolf Pro Ventilation 35 wolfappliance.com/specs Pro 27" Deep Wall Hood INSTALLATION DUCTWORK INSTALLATION THROUGH ROOF LOCATE ELECTRICAL WITHIN SHADED AREA 6" (152) E 5" 12" (127) (305) 18" (457) HOOD HEIGHT 4" (102) 30" (762), 36" (914), 42" (1067) 48" (1219), 54" (1372) 60" (1524) OR 66" (1676) HOOD WIDTH 27" (686) HOOD DEPTH 30" (762) TO 36" (914) BOTTOM OF HOOD TO COUNTERTOP NOTE: Alternative horizontal discharge requires accessory kit. Refer to instructions provided with kit for detailed specifications. Wolf Pro Ventilation 36 Pro Wall Chimney Hood Model Options 18" (457) 24" MODEL WIDTH WEIGHT PWC362418 36" (914) 78 lbs (35 kg) PWC422418 42" (1067) 86 lbs (39 kg) PWC482418 48" (1219) 94 lbs (43 kg) PWC542418 54" (1372) 106 lbs (48 kg) WIDTH (610) FEATURES Specifications • Install with accessory duct cover for chimney-style hood. PRO VENTILATION • Heavy-duty, brushed stainless steel exterior with enclosed liner. Installation Type Wall Exterior Finish Stainless Steel • Internal, in-line and remote blower options. Widths • Welded seams, hemmed edges and hand-finished craftsmanship. 36" (914), 42" (1067), 48" (1219) and 54" (1372) Height 18" (457) Depth 24" (610) Installation Height 30" (762) to 36" (914) bottom of hood to countertop • Recessed easy-access controls. • Infinite-speed blower control. • Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed. Electrical Supply 120 V AC, 60 Hz, 15 amp dedicated circuit • Halogen lighting with two settings. Halogen Bulbs Two or three 50 W, 120 V par 20 bulbs (included) • Removable, dishwasher-safe stainless steel baffle filters. • Transition with backdraft damper. Discharge Vertical Duct Size 10" (254) Round Transition Rectangle to 10" (254) round, 7" (178) height (included) ACCESSORIES • Internal, in-line and remote blowers (refer to chart below). • 38" (965) high stainless steel backsplash with or without warming racks. • 6" (152), 12" (305), 18" (457), 24" (610) high stainless steel duct covers. Blower Options CFM INTERNAL 300* 450* PWC362418 PWC422418 • • PWC482418 PWC542418 • • 500 IN-LINE 600 900 • • • *For make-up air restricted applications. Capture and performance may be reduced. 1200 • 600 REMOTE 1100 900 1200 1500 • 600 • • • • • • • Wolf Pro Ventilation 37 wolfappliance.com/specs Pro Wall Chimney Hood INSTALLATION DUCTWORK INSTALLATION THROUGH ROOF 5" LOCATE (127) ELECTRICAL WITHIN 6" E SHADED AREA (152) WIDTH MINUS 18" (457) OPTIONAL DUCT COVER 13 1/2" (343) 18" (457) HOOD HEIGHT 4" (102) 36" (914), 42" (1067) 48" (1219) OR 54" (1372) 24" (610) HOOD DEPTH HOOD WIDTH 30" (762) TO 36" (914) BOTTOM OF HOOD TO COUNTERTOP Wolf Pro Ventilation 38 Pro Island Hood Model Options 18" (457) 34" MODEL WIDTH WEIGHT PI362418 36" (914) 95 lbs (43 kg) PI422418 42" (1067) 103 lbs (47 kg) PI542418 54" (1372) 128 lbs (58 kg) PI662418 66" (1676) 168 lbs (76 kg) WIDTH (864) FEATURES Specifications • Heavy-duty, brushed stainless steel exterior with enclosed liner. PRO VENTILATION Installation Type Island • Internal, in-line and remote blower options. Exterior Finish Stainless Steel • Welded seams, hemmed edges and hand-finished craftsmanship. Widths 36" (914), 42" (1067), 54" (1372) and 66" (1676) • Recessed easy-access controls. Height 18" (457) Depth 34" (864) Installation Height 30" (762) to 36" (914) bottom of hood to countertop Electrical Supply 120 V AC, 60 Hz, 15 amp dedicated circuit Halogen Bulbs Two or three 50 W, 120 V par 20 bulbs (included) • Infinite-speed blower control. • Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed. • Halogen lighting with two settings. • Removable, dishwasher-safe stainless steel baffle filters. • Transition with backdraft damper. ACCESSORIES • Internal, in-line and remote blowers (refer to chart below). • 6" (152), 12" (305), 18" (457), 24" (610) high stainless steel duct covers. Blower Options CFM Discharge Vertical Duct Size 10" (254) Round Transition Rectangle to 10" (254) round, 61/2" (165) height (included) INTERNAL 300* 450* PI363418 PI423418 • • PI543418 • • PI663418 • • 500 IN-LINE 600 900 1200 900 1200 1500 • • • • • • • • • • • • • • • • • *For make-up air restricted applications. Capture and performance may be reduced. 600 REMOTE 1100 600 Wolf Pro Ventilation 39 wolfappliance.com/specs Pro Island Hood INSTALLATION DUCTWORK INSTALLATION THROUGH ROOF LOCATE ELECTRICAL THROUGH TOP OF HOOD WIDTH MINUS 18" (457) 13" 18" (457) (330) HOOD HEIGHT 4" (102) 36" (914), 42" (1067) 54" (1372) OR 66" (1676) 34" (864) HOOD DEPTH HOOD WIDTH 30" (762) TO 36" (914) BOTTOM OF HOOD TO COUNTERTOP NOTE: Do not run electrical wiring through ductwork. Wolf Pro Ventilation 40 Pro Hood Liner Model Options 12" (305) 22 1/2" WIDTH (572) FEATURES MODEL WIDTH WEIGHT PL342212 34 3/8" (873) 44 lbs (20 kg) PL402212 40 3/8" (1026) 50 lbs (23 kg) PL462212 46 3/8" (1178) 55 lbs (25 kg) PL522212 52 3/8" (1330) 60 lbs (27 kg) PL582212 58 3/8" 65 lbs (29 kg) (1483) Specifications • Heavy-duty stainless steel enclosed liner for custom hood applications. PRO VENTILATION Installation Type Wall Hood Liner • Internal, in-line and remote blower options. Exterior Finish Stainless Steel • Recessed easy-access controls. Widths • Infinite-speed blower control. 34 3/8" (873), 40 3/8" (1026) 46 3/8" (1178), 52 3/8" (1330) and 58 3/8" (1483) • Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed. Height 12" (305) Depth 22 1/2" (572) • Halogen lighting with two settings. Installation Height • Removable, dishwasher-safe stainless steel baffle filters. 30" (762) to 36" (914) bottom of hood to countertop • Transition with backdraft damper. Electrical Supply 120 V AC, 60 Hz, 15 amp dedicated circuit Halogen Bulbs Two 50 W, 120 V par 20 bulbs (included) ACCESSORIES • Internal, in-line and remote blowers (refer to chart below). Blower Options CFM Discharge Vertical Transition 221/2 (572) x 9 5/8 (244) to 10" (254) round, 8 3/4 (222) height (included) INTERNAL 500 IN-LINE 300* 450* 600 900 PL342212 PL402212 • • • • PL462212 • • • • PL522212 • • PL582212 • • • *For make-up air restricted applications. Capture and performance may be reduced. 1200 • 600 REMOTE 1100 900 1200 1500 • 600 • • • • • • • • • • • • • • • • • Wolf Pro Ventilation 41 wolfappliance.com/specs Pro Hood Liner INSTALLATION DUCTWORK INSTALLATION THROUGH ROOF LOCATE ELECTRICAL WITHIN SHADED AREA 6" E (152) 5" DECORATIVE HOOD (127) WIDTH MINUS 6" (152) 12" 12" (305) (305) LINER HEIGHT 4" (102) 34 3/8" (873), 40 3/8" (1026) 46 3/8" (1178), 52 3/8" (1330) OR 58 3/8" (1483) LINER WIDTH 221/2" (572) LINER DEPTH 30" (762) TO 36" (914) BOTTOM OF HOOD TO COUNTERTOP NOTE: A custom decorative hood can be created out of wood, plaster, tile or metal. The shape of the decorative hood is not critical as long as the hood liner fits completely inside the hood. The decorative hood and liner must fit together at the bottom edge in both width and depth. The height of the hood does not have to match the height of the liner. Interior dimensions of the decorative hood must exceed exterior dimensions of the liner. Wolf Pro Ventilation 42 Recirculating Ventilation Recirculating units are an alternative option for customers required by code to install make-up air systems or where running ventilation ductwork is an issue. They are also an alternative option to ductwork for high rise buildings and apartments. No ductwork is required for the recirculating ventilation unit. IMPORTANT NOTE: Wolf recirculating ventilation units should not be used with Wolf range or rangetop models with a charbroiler or griddle. FEATURES • Heavy-duty stainless steel unit fits above ventilation hood for recirculating applications. • No ductwork required. • Charcoal filters. ACCESSORIES • Replacement charcoal filters. Model Options MODEL WIDTH WEIGHT 811838 30" (762) 20 lbs (9 kg) 811839 36" (914) 23 lbs (10 kg) Specifications RECIRCULATING Installation Type Wall Exterior Finish Stainless Steel Widths 30" (762) and 36" (914) Height 4" (102) Depth 12" (305) Pro Hoods PW302210, PW362210, PW302418, PW362418, PW302718 and PW362718 Wolf Pro Ventilation 43 wolfappliance.com/specs Recirculating Ventilation INSTALLATION 5" (127) LOCATE ELECTRICAL WITHIN SHADED AREA 6" (152) RECIRCULATING UNIT E 4" (102) 10" (254) OR 18" (457) HOOD HEIGHT 30" (762) OR 36" (914) HOOD AND RECIRCULATING UNIT WIDTH 12" (305) 22" (559) 24" (610) OR 27" (686) 30" (762) TO 36" (914) BOTTOM OF HOOD TO COUNTERTOP HOOD DEPTH Wolf Blower Specifications 44 Internal Blower Specifications 450 CFM INTERNAL BLOWER 600 CFM INTERNAL BLOWER Specifications Specifications 801643 801644 Cooktop Hoods CTWH30 Cooktop Hoods CTWH36 and IH4227 Duct Size 8" (203) Round Duct Size 8" (203) Round Electrical Rating 2.4 amps at 120 V AC, 60 Hz Electrical Rating 3.0 amps at 120 V AC, 60 Hz Roof or Wall Cap Required Roof or Wall Cap Required Shipping Weight 14 lbs (6 kg) Shipping Weight 15 lbs (7 kg) 1.0 1.0 0.9 0.8 Static Pressure (in-wg) Static Pressure (in-wg) 0.9 Calculated for Rigid 10" Galvanized Duct 0.8 0.7 0.6 0.5 0.4 High Med 0.3 0.2 0 100 200 300 400 Airflow Rate (CFM) 0.6 High Med 0.5 0.4 Low 0.3 0.2 Low 100' 75' 50' 25' 10' 0.1 0 Calculated for Rigid 10" Galvanized Duct 0.7 500 100' 75' 50' 25' 10' 0.1 600 Airflow rate with cooktop hoods. NOTE: Airflow rates for blowers are approximate. A qualified HVAC professional should make actual system calculations. 0 0 100 200 300 400 Airflow Rate (CFM) Airflow rate with cooktop hoods. 500 600 700 Wolf Blower Specifications 45 wolfappliance.com/specs Internal Blower Specifications 900 CFM INTERNAL BLOWER Specifications 801645 Cooktop Hoods CTWH36 and IH4227 Duct Size 8" (203) Round Electrical Rating 2.4 amps at 120 V AC, 60 Hz Roof or Wall Cap Required Shipping Weight 26 lbs (12 kg) Wolf Blower Specifications 46 Internal Blower Specifications 500 CFM INTERNAL BLOWER 600 CFM INTERNAL BLOWER Specifications Specifications 810991 810559 Pro Hoods PW302210 and PW362210 Duct Size 8" (203) or 10" (254) Round (depending on hood) Electrical Rating 1.8 amps at 120 V AC, 60 Hz Roof or Wall Cap Required Shipping Weight 15 lbs (7 kg) Pro Hoods PW302418, PW362418, PW422418, PW302718, PW362718 and PW422718 Duct Size 8" (203) or 10" (254) Round (depending on hood) Electrical Rating 3.8 amps at 120 V AC, 60 Hz Roof or Wall Cap Required Shipping Weight 15 lbs (7 kg) Wolf Blower Specifications 47 wolfappliance.com/specs Internal Blower Specifications 900 CFM INTERNAL BLOWER 1200 CFM INTERNAL BLOWER Specifications Specifications 811131 810316 Pro Hoods PW302418, PW362418, PW422418, PW302718, PW362718 and PW422718 Pro Hoods Duct Size 10" (254) Round Electrical Rating 7.6 amps at 120 V AC, 60 Hz Duct Size 10" (254) Round Roof or Wall Cap Required Electrical Rating 3.4 amps at 120 V AC, 60 Hz Shipping Weight 30 lbs (14 kg) Roof or Wall Cap Required Shipping Weight 34 lbs (15 kg) 1.1 1.0 1.0 0.9 Calculated for Rigid 10" Galvanized Duct 0.7 0.6 Calculated for Rigid 10" Galvanized Duct 0.9 Static Pressure (in-wg) Static Pressure (in-wg) 0.8 High 0.5 0.4 Low 0.3 100' 0.2 75' 0.8 High 0.7 0.6 0.5 0.4 100' 0.3 75' 0.2 50' 0.1 25' 10' 50' 0.1 0 PW482418, PW542418, PW602418, PW662418, PW482718, PW542718, PW602718 and PW662718 25' 10' 0 100 200 300 400 500 Airflow Rate (CFM) Airflow rate with pro wall hoods. 600 700 800 0 0 100 200 300 400 500 600 Airflow Rate (CFM) Airflow rate with pro wall hoods. 700 800 900 1000 Wolf Blower Specifications 48 Internal Blower Specifications 1200 CFM INTERNAL BLOWER 1200 CFM INTERNAL BLOWER Specifications Specifications 804703 805087 PWC482418 and PWC542418 All pro island hoods Pro Hoods All pro hood liners Duct Size 10" (254) Round Duct Size 10" (254) Round Electrical Rating 3.4 amps at 120 V AC, 60 Hz Electrical Rating 4.5 amps at 120 V AC, 60 Hz Roof or Wall Cap Required Roof or Wall Cap Required Shipping Weight 34 lbs (15 kg) Shipping Weight 27 lbs (12 kg) 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1.0 Calculated for Rigid 10" Galvanized Duct 0.9 Calculated for Rigid 10" Galvanized Duct 0.8 High 100' 75' Low Static Pressure (in-wg) Static Pressure (in-wg) Pro Hoods 0.7 0.6 High 0.5 0.4 0.3 50' 0.2 25' 0.1 100' 75' 50' 25' 10' 10' 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Airflow Rate (CFM) Airflow rate with pro island hoods. NOTE: Airflow rates for blowers are approximate. A qualified HVAC professional should make actual system calculations. 0 0 100 200 300 400 500 Airflow Rate (CFM) Airflow rate with pro hood liners. 600 700 800 Wolf Blower Specifications 49 wolfappliance.com/specs In-line Blower Specifications 600 CFM IN-LINE BLOWER Specifications 808331 Dimensions (W x H x D) 24 3/8" (619) x 11 3/4" (298) x 121/4" (311) Cooktop Hoods CTWH30, CTWH36 and IH4227 Pro Hoods All pro low-profile wall hoods PW302418 and PW302718 Duct Size 10" (254) Round Transition 41/2" (114) x 181/2" (470) to 10" (254) Round (two transitions included) Electrical Rating 2.9 amps at 120 V AC, 60 Hz Roof or Wall Cap Required Shipping Weight 44 lbs (20 kg) 24 3/8" (619) 11 3/4" (298) 18 1/2" (470) 4 1/2" (114) 211/2" (546) 12 1/4" (311) 600 CFM in-line blower. Wolf Blower Specifications In-line Blower Specifications 1100 CFM IN-LINE BLOWER Specifications 808332 Dimensions (W x H x D) 24 7/8" (632) x 18" (457) x 18" (457) Cooktop Hoods CTWH30, CTWH36 and IH4227 Downdrafts DD30R, DD36R and DD45R Pro Hoods All pro 24" deep wall hoods All pro 27" deep wall hoods All pro wall chimney hoods All pro island hoods All pro hood liners Duct Size 10" (254) Round Transition 8 1/2" (216) x 12" (305) to 10" (254) Round (two transitions included) Electrical Rating 5.0 amps at 120 V AC, 60 Hz Roof or Wall Cap Required Shipping Weight 63 lbs (29 kg) 24 7/8" (632) 18" (457) 12" (305) 8" (203) 22" (559) 1100 CFM in-line blower. 18" (457) 50 Wolf Blower Specifications 51 wolfappliance.com/specs Remote Blower Specifications 600 CFM REMOTE BLOWER 1.0 Specifications Calculated for Rigid 10" Galvanized Duct 0.9 801640 Cooktop Hoods CTWH30, CTWH36 and IH4227 x 24 1/2" (622) x 4 3/4" (121) Pro Hoods All pro low-profile wall hoods PW302418 and PW302718 Duct Size 10" (254) Round Electrical Rating 2.4 amps at 120 V AC, 60 Hz Shipping Weight 32 lbs (15 kg) Static Pressure (in-wg) Dimensions (W x H x D) 21 3/4" (527) 0.8 0.7 100' 75' 50' 25' Hood Only High 0.6 Med 0.5 Low 0.4 0.3 0.2 0.1 0 0 100 200 300 400 Airflow Rate (CFM) 500 600 700 Airflow rate with cooktop hoods. 20 3/4" (718) NOTE: Airflow rates for blowers are approximate. A qualified HVAC professional should make actual system calculations. (527) 28 1/4" 10" (254) DIAMETER 15 1/2" (394) 24 1/2" (622) 14" (356) 4 3/4" 24 3/4" (629) 900 CFM remote blower. (121) Wolf Blower Specifications 52 Remote Blower Specifications 900 CFM REMOTE BLOWER 100' 50' Downdraft Only 1.1 Specifications Calculated for Rigid 10" Galvanized Duct 1.0 801641 Dimensions (W x H x D) 21 3/4" (527) x 24 1/2" (622) x 4 3/4" (121) Cooktop Hoods CTWH30, CTWH36 and IH4227 Downdrafts DD30R, DD36R and DD45R Pro Hoods All pro low-profile wall hoods PW302418, PW362418, PW422418 PW482418 and PW542418 PW302718, PW362718, PW422718 PW482718 and PW542718 All pro wall chimney hoods PI363418, PI423418 and PI543418 All pro hood liners Duct Size 10" (254) Round Electrical Rating 5.7 amps at 120 V AC, 60 Hz Shipping Weight 32 lbs (15 kg) Static Pressure (in-wg) 0.9 0.8 High 0.7 0.6 0.5 0.4 Med 0.3 0.2 Low 0.1 0 0 100 200 300 400 500 600 Airflow Rate (CFM) 700 800 900 1000 Airflow rate with 30" (762) downdraft. 100' 50' Downdraft Only 1.1 Calculated for Rigid 10" Galvanized Duct 1.0 Static Pressure (in-wg) 0.9 20 3/4" (527) 28 1/4" (718) 10" (254) DIAMETER 15 1/2" 24 1/2" (394) 0.8 0.7 0.6 0.5 High 0.4 0.3 Low 0.2 (622) 0.1 0 0 100 200 300 14" (356) 400 500 600 Airflow Rate (CFM) 700 800 900 1000 900 1000 Airflow rate with 36" (914) downdraft. 4 3/4" 24 3/4" Med (121) (629) Static Pressure (in-wg) 900 CFM remote blower. 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 100' 75' 50' 25' Hood Only Calculated for Rigid 10" Galvanized Duct High Med Low 0 100 200 300 400 500 600 Airflow Rate (CFM) 700 800 Airflow rate with 30" (762) to 42" (1067) pro wall hoods. Wolf Blower Specifications 53 wolfappliance.com/specs Remote Blower Specifications 900 CFM REMOTE BLOWER 1.1 NOTE: Airflow rates for blowers are approximate. A qualified HVAC professional should make actual system calculations. 1.0 Static Pressure (in-wg) 0.9 100' Calculated for Rigid 10" Galvanized Duct 0.8 0.7 75' 50' 0.6 25' 0.5 Hood Only 0.4 High 0.3 Med 0.2 0.1 0 Low 0 100 200 300 400 500 600 Airflow Rate (CFM) 700 800 900 1000 Airflow rate with 48" (1219) to 66" (1676) pro wall hoods. 100' 1.1 75' 1.0 50' 25' Static Pressure (in-wg) 0.9 Hood Only Calculated for Rigid 10" Galvanized Duct 0.8 0.7 0.6 0.5 0.4 High 0.3 Med 0.2 Low 0.1 0 0 100 200 300 400 500 600 Airflow Rate (CFM) 700 800 900 1000 900 1000 Airflow rate with pro island hoods. 100' 75' 50' 25' Hood Only 1.1 1.0 Static Pressure (in-wg) 0.9 Calculated for Rigid 10" Galvanized Duct 0.8 0.7 0.6 0.5 High 0.4 0.3 Med 0.2 Low 0.1 0 0 100 200 300 400 500 600 Airflow Rate (CFM) Airflow rate with pro hood liners. 700 800 Wolf Blower Specifications 54 Remote Blower Specifications 1200 CFM REMOTE BLOWER 100' Specifications 291/2" Dimensions (W x H x D) 18" (457) x Cooktop Hoods CTWH30, CTWH36 and IH4227 (749) x 10" (254) Downdrafts DD30R, DD36R and DD45R Pro Hoods All pro 24" deep wall hoods All pro 27" deep wall hoods All pro wall chimney hoods All pro island hoods All pro hood liners Duct Size 10" (254) Round Electrical Rating 3.0 amps at 120 V AC, 60 Hz Shipping Weight 38 lbs (17 kg) Static Pressure (in-wg) 801642 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 50' Hood Only Calculated for Rigid 10" Galvanized Duct High Med Low 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Airflow Rate (CFM) Airflow rate with 30" (762) downdraft. ( ) 100' 10" (254) 29 1/2" (749) 10" (254) DIAMETER 14 3/4" 29 1/2" (375) (749) Static Pressure (in-wg) 18" (457) 10 1/8" (257) 22" (559) 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 Hood Only Calculated for Rigid 10" Galvanized Duct High Med Low 0 7 1/4" (184) 50' 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Airflow Rate (CFM) Airflow rate with 36" (914) downdraft. A 1200 CFM remote blower. 100' 75' 50' 25' Hood Only 1.2 Calculated for Rigid 10" Galvanized Duct 1.1 Static Pressure (in-wg) 1.0 0.9 High 0.8 0.7 0.6 0.5 0.4 0.3 Med 0.2 0.1 0 Low 0 200 400 600 800 Airflow Rate (CFM) 1000 1200 Airflow rate with 30" (762) to 42" (1067) pro wall hoods. 1400 Wolf Blower Specifications 55 wolfappliance.com/specs Remote Blower Specifications 1200 CFM REMOTE BLOWER NOTE: Airflow rates for blowers are approximate. A qualified HVAC professional should make actual system calculations. 1.2 Calculated for Rigid 10" Galvanized Duct 1.1 Static Pressure (in-wg) 1.0 100' 50' 75' 25' 0.9 0.8 Hood Only 0.7 0.6 Med 0.5 High 0.4 0.3 Low 0.2 0.1 0 0 200 400 600 800 Airflow Rate (CFM) 1000 1200 1400 Static Pressure (in-wg) Airflow rate with 48" (1219) to 66" (1676) pro wall hoods. 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 100' 75' Calculated for Rigid 10" Galvanized Duct 50' 25' Hood Only High Med Low 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Airflow Rate (CFM) Airflow rate with pro island hoods. Static Pressure (in-wg) 100' 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 75' 50' 25' Hood Only Calculated for Rigid 10" Galvanized Duct High Med Low 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Airflow Rate (CFM) Airflow rate with pro hood liners. Wolf Blower Specifications 56 Remote Blower Specifications 1500 CFM REMOTE BLOWER 100' Specifications Dimensions (W x H x D) 21" (533) x 291/2" (749) x 10" (254) Cooktop Hoods CTWH30, CTWH36 and IH4227 Downdrafts DD30R, DD36R and DD45R Pro Hoods All pro 24" deep wall hoods All pro 27" deep wall hoods All pro wall chimney hoods All pro island hoods All pro hood liners Duct Size 10" (254) Round Electrical Rating 4.3 amps at 120 V AC, 60 Hz Shipping Weight 45 lbs (20 kg) Static Pressure (in-wg) 804701 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 75' 50' 25' Hood Only Calculated for Rigid 10" Galvanized Duct High Med Low 0 200 400 600 800 1000 Airflow Rate (CFM) 1200 1400 1600 Airflow rate with cooktop hoods. 100' 10" (254) 29 1/2" (749) 10" (254) DIAMETER 14 3/4" 29 1/2" (375) (749) Static Pressure (in-wg) 21" (533) 10 3/8" (264) 25" 7 1/4" (635) (184) 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 50' Hood Only Calculated for Rigid 10" Galvanized Duct High Med Low 0 200 400 600 800 1000 Airflow Rate (CFM) 1200 1400 1600 Airflow rate with 36" (914) downdraft. 1500 CFM remote blower. Static Pressure (in-wg) 100' 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 75' 50' 25' Hood Only Calculated for Rigid 10" Galvanized Duct High Med Low 0 200 400 600 800 1000 Airflow Rate (CFM) 1200 1400 Airflow rate with 30" (762) to 42" (1067) pro wall hoods. 1600 Wolf Blower Specifications 57 wolfappliance.com/specs Remote Blower Specifications Static Pressure (in-wg) 1500 CFM REMOTE BLOWER 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 100' NOTE: Airflow rates for blowers are approximate. A qualified HVAC professional should make actual system calculations. 75' Calculated for Rigid 10" Galvanized Duct Hood Only 50' 25' High Med Low 0 200 400 600 800 1000 Airflow Rate (CFM) 1200 1400 1600 Airflow rate with 48" (1219) to 66" (1676) pro wall hoods. Static Pressure (in-wg) 100' 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 75' 50' 25' Hood Only Calculated for Rigid 10" Galvanized Duct High Med Low 0 200 400 600 800 1000 Airflow Rate (CFM) 1200 1400 1600 Airflow rate with pro island hoods. Static Pressure (in-wg) 100' 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 75' 50' 25' Hood Only Calculated for Rigid 10" Galvanized Duct High Med Low 0 200 400 600 800 1000 Airflow Rate (CFM) Airflow rate with pro hood liners. 1200 1400 1600 Wolf Blower Specifications 58 In-Line Blower Installation 600 CFM IN-LINE BLOWER Ductwork options are provided in the illustrations below for installation of the 600 CFM in-line blower with horizontal or vertical discharge. Refer to installation instructions shipped with the in-line blower for detailed specifications. Choose the mounting option for the 600 CFM in-line blower that best suits your installation. A) Mounting brackets in factory-shipped position. Discharge parallel to joists. B) Mounting brackets flipped over and mounted to discharge sides of housing. Discharge parallel to joists. C) Mounting brackets mounted to discharge sides of housing. Discharge perpendicular to joists. ROOF CAP 41/2" (114) x 181/2" (470) TO 10" (254) E) Mounting brackets mounted to top of sides of housing. Discharge parallel to joists. 10" (254) ROUND DUCT ROUND TRANSITION WALL CAP 10" (254) ROUND DUCT D) Mounting brackets flipped over to give approximately 1" (25) more clearance. Discharge parallel to joists. F) Mounting brackets flipped over and mounted to top of sides of housing. Discharge parallel to joists. ELBOW 11/8" 11/2" (38) TO 21/2" (29) MAX Horizontal discharge. A 211/2" (546) (64) D 211/2" (546) ROOF CAP 41/2" (114) x 181/2" (470) TO 10" (254) ROUND TRANSITION 91/2" (241) TO 101/2" (267) 11/2" (38) TO 21/2" (64) 10" (254) ROUND DUCT B 211/2" (546) E 211/2" (546) 10 3/4" (273) TO 11 3/4" (298) 10" (254) ROUND DUCT Vertical discharge. C 121/4" (311) Mounting options. F 211/2" (546) Wolf Blower Specifications 59 wolfappliance.com/specs In-Line Blower Installation 1100 CFM IN-LINE BLOWER Ductwork options are provided in the illustrations below for installation of the 1100 CFM in-line blower with horizontal or vertical discharge. Refer to installation instructions shipped with the in-line blower for detailed specifications. Choose the mounting option for the 1100 CFM in-line blower that best suits your installation. A) Mounting brackets in factory-shipped position, mounted directly to joists. Discharge parallel to joists. B) Mounting brackets flipped over and mounted to additional framing. Discharge perpendicular to joists. C) Mounting brackets flipped over and mounted to additional framing. Discharge vertical. ROOF CAP 8" (203) x 12" (305) TO 10" (254) 10" (254) ROUND TRANSITIONS D) Mounting brackets flipped over and mounted to top of housing. Housing secured with cables. Discharge parallel to joists. ROUND DUCT WALL CAP 10" (254) ROUND DUCT ELBOW STRAIGHTTHROUGH DISCHARGE 11/8" STRAIGHTTHROUGH DISCHARGE Horizontal discharge. (29) MAX 22" (559) C 18" (457) ROOF CAP ROUND TRANSITIONS 10" (254) RIGHT-ANGLE DISCHARGE ROUND DUCT 11/2" (38) TO STRAIGHTTHROUGH DISCHARGE 21/2" (64) B 18" (457) 10" (254) ROUND DUCT Mounting options. Vertical discharge. (38) TO 21/2" (64) A 8" (203) x 12" (305) TO 10" (254) 11/2" 22" (559) D Wolf Blower Specifications 60 Remote Blower Installation 600 AND 900 CFM REMOTE BLOWERS (216) REMOVE SHINGLES 103/8" (264) 11" (279) DIAMETER ROOF RAFTER If the remote blower is to be installed on a flat roof, a curb will have to be constructed for a proper fit. Follow dimensions shown in the illustration below. 203/4" (527) 81/2" ROOF RAFTER Cut-out dimensions are provided in the illustrations for installation of the 600 CFM or 900 CFM remote blower on the roof or an exterior wall. Refer to installation instructions shipped with the remote blower for detailed specifications. PILOT HOLE 11/4" (32) DIAMETER 2" 201/2" (521) 91/8" (232) 71/4" (51) (184) 291/2" EXTERIOR ROOF VIEW (749) Roof installation. 7" (178) 25" 2" (635) (51) 243/4" (629) 103/4" (273) Curb for flat roof. (327) REMOVE SIDING (216) 11" (279) DIAMETER PILOT HOLE 11/4" (32) DIAMETER 71/4" (184) EXTERIOR WALL VIEW Exterior wall installation. WALL STUD 127/8" WALL STUD 81/2" 281/4" 91/8" (232) (718) Wolf Blower Specifications 61 wolfappliance.com/specs Remote Blower Installation 1200 CFM REMOTE BLOWER 15" (381) 11/4" (32) DIAMETER If the remote blower is to be installed on a flat roof, a curb will have to be constructed for a proper fit. Follow dimensions shown in the illustration below. REMOVE SHINGLES 1" (25) ROOF RAFTER 1211/16" (322) ROOF RAFTER Cut-out dimensions are provided in the illustrations for installation of the 1200 CFM remote blower on the roof or an exterior wall. Refer to installation instructions shipped with the remote blower for detailed specifications. PILOT HOLE (CENTERED BETWEEN RAFTERS) 201/2" (521) 11" (279) DIAMETER 913/16" 2" (249) (51) 18" (457) 291/2" EXTERIOR ROOF VIEW (749) Roof installation. 7" (178) (559) (51) Curb for flat roof. 17" (431) 1411/16" (373) PILOT HOLE (CENTERED BETWEEN STUDS) REMOVE SIDING 11/4" (32) DIAMETER 3" (76) WALL STUD 2" WALL STUD 22" 11" (279) DIAMETER 1113/16" (300) 22" (559) EXTERIOR WALL VIEW Exterior wall installation. 291/2" (749) Wolf Blower Specifications 62 Remote Blower Installation 1500 CFM REMOTE BLOWER 18" (457) 11/4" (32) DIAMETER REMOVE SHINGLES 1211/16" If the remote blower is to be installed on a flat roof, a curb will have to be constructed for a proper fit. Follow dimensions shown in the illustration below. 1" (25) PILOT HOLE (CENTERED BETWEEN RAFTERS) ROOF RAFTER (322) ROOF RAFTER Cut-out dimensions are provided in the illustrations for installation of the 1500 CFM remote blower on the roof or an exterior wall. Refer to installation instructions shipped with the remote blower for detailed specifications. 201/2" (521) 11" (279) DIAMETER 12 5/8" 2" (321) (51) 21" (533) 291/2" EXTERIOR ROOF VIEW (749) Roof installation. 7" (178) 2" (559) (51) 20" (508) Curb for flat roof. 1411/16" WALL STUD (373) 11/4" (32) PILOT HOLE DIAMETER (CENTERED BETWEEN STUDS) 11" (279) DIAMETER REMOVE SIDING 145/8" (371) 25" (635) EXTERIOR WALL VIEW Exterior wall installation. 3" (76) WALL STUD 22" 291/2" (749) Wolf Ventilation FAQ 63 wolfappliance.com/specs Frequently Asked Questions HOW TO DETERMINE WHICH TYPE OF BLOWER TO USE? HOW CAN THE DUCT RUN BE MOST EFFICIENT? Many factors can influence the decision between using an internal, in-line or remote blower. The CFM (based on the cooking appliance output), length of the duct run and space available to mount the blower are primary considerations. For maximum performance keep the duct run straight and short, with a limited number of elbows and transitions. 45° elbows are more efficient than 90° elbows. Be sure to use an external roof or wall cap. Wolf ventilation products will operate most efficiently when ductwork does not exceed 50' (15 m) in length. Internal blowers are mounted inside the hood or downdraft. In-line blowers are mounted between the hood and the exterior of the home. Remote blowers can be mounted on the roof or, in some cases, on an exterior wall. HOW CAN BLOWER NOISE BE MINIMIZED? Some blower noise is considered normal while the blower is operating. If noise is a concern, a remote blower is recommended. Using a remote blower will minimize the amount of blower noise but will not eliminate the noise completely. Where the remote blower is installed on the home will also affect the amount of noise. To reduce noise further for remote blower applications, an attenuator may be necessary. An attenuator is an electronic device that is effectively the opposite of an amplifier. While an amplifier provides gain, an attenuator provides loss in sound level. WHAT IS MAKE-UP AIR? When a ventilation hood or downdraft is operating, it draws air from inside the house to the outside, creating a slight vacuum within the house. This creates negative pressure (pressure inside the house is less than the pressure outside). If the negative pressure is strong enough, it can cause the furnace and other fuel-burning appliances to backdraft dangerous gases such as carbon monoxide into the home. All exhaust fans need an adequate supply of fresh air from the outside to operate safely. The air needed for this purpose is called “make-up air.” Check with a local HVAC professional to determine if your heating or air conditioning system makes allowances for additional make-up air. Make-up air can be introduced by simply opening a window or door. WHAT TYPE OF DUCTING IS RECOMMENDED? Wolf hoods and downdrafts should be vented using smooth, rigid metal ducting. The ridges found in flexible metal ducting create turbulence and will diminish airflow. The larger the ducting, the less noise there will be and the better the rate of airflow. The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. ©Wolf Appliance, Inc. all rights reserved. Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc. Sub-Zero, Sub-Zero & Design, Dual Refrigeration, Constant Care and The Living Kitchen are registered trademarks and service marks of Sub-Zero, Inc. (collectively, the “Company Marks.”) All other trademarks or registered trademarks are property of their respective owners in the United States and other countries. Wolf Appliance Products Limited Warranty FOR RESIDENTIAL USE ONLY FULL TWO YEAR WARRANTY* For two years from the date of original installation, your Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours. LIMITED FIVE YEAR WARRANTY For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: gas burners (excluding appearance), electric heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and induction generators. The part(s) will be repaired or replaced, free of charge, with the owner paying for all other costs including labor. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours. TERMS APPLICABLE TO EACH WARRANTY The warranty applies only to products installed for normal residential use. The warranty applies only to products installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of Canada. This warranty does not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service or repair. THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE, INC. WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION OF LAW. WOLF APPLIANCE, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR STATUTORY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state. To receive parts and/or service and the name of Wolf factory certified service nearest you, contact Wolf Appliance, Inc., P. O. Box 44848, Madison, WI 53744; check the contact & support section of our website, wolfappliance.com or call 800-222-7820. *Stainless steel doors, panels, handles, product frames and interior surfaces are covered by a limited 60-day parts and labor warranty for cosmetic defects. *Replacement filters for ventilation hood recirculating kits are not covered by the product warranty. Wolf Appliance Outdoor Products Limited Warranty PRODUCT MUST BE APPROVED FOR OUTDOOR USE, DESIGNATED BY MODEL AND SERIAL NUMBER FOR RESIDENTIAL USE ONLY FULL ONE YEAR WARRANTY* For one year from the date of original installation, your Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours. LIMITED FIVE YEAR WARRANTY Wolf Appliance warrants the stainless steel briquette trays, gas valves, drip pans, electronic control boards and electric heating elements to be free from defects in materials and workmanship under normal residential use for a period of five years from the date of original installation. The part(s) will be repaired or replaced, free of charge, with the owner paying for all other costs including labor. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours. LIMITED LIFETIME WARRANTY For the life of the product, Wolf Appliance will repair or replace any stainless steel part including all fabricated stainless steel components, stainless steel burners and grates (excluding what is covered in the Limited Five Year Warranty) to be defective from workmanship and when subjected to normal domestic use and service. This warranty excludes surface corrosion, scratches, discoloration, weather and atmospheric related staining, and minor surface rust and oxidation which are normal conditions. Labor to remove and replace defective parts is not covered. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. TERMS APPLICABLE TO EACH WARRANTY The warranty applies only to products installed for normal residential use. The warranty applies only to products installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of Canada. This warranty does not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service or repair. THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE, INC. WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION OF LAW. WOLF APPLIANCE, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR STATUTORY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state. To receive parts and/or service and the name of Wolf factory certified service nearest you, contact Wolf Appliance, Inc., P. O. Box 44848, Madison, WI 53744; check the contact & support section of our website, wolfappliance.com or call 800-222-7820. *Stainless steel doors, panels, handles, product frames and interior surfaces are covered by a limited 60-day parts and labor warranty for cosmetic defects. WOLF APPLIANCE, INC. P. O. BOX 44848 WVG MADISON, WI 53744 6 / 2012 WOLFAPPLIANCE.COM 800.222.7820