TLCN, TLCHN hot water circulators
Transcription
TLCN, TLCHN hot water circulators
50 Hz TLCN, TLCHN Series WET ROTOR CIRCULATORS FOR SANITARY SYSTEMS Cod. 191027201 Rev. B Ed.12/2014 TCLN, TLCHN SERIES INSTALLATION POSITIONS Lowara, Xylect are trademarks of Xylem Inc. or one of its subsidiaries. 2 Sanitary Circulators MARKET SECTORS RESIDENTIAL. APPLICATIONS • Circulation of sanitary hot water. TLCN Series SPECIFICATIONS PUMP Flow rate: up to 4 m3/h. Head: up to 6 m. Temperature of pumped liquid: +2°C ÷ +110°C (recommended up to 65°C). Avoid condensation and ice formation. • Maximum operating pressure: 10 bar (PN 10). • Impeller: made of composite material. • Wear ring: ceramic. • • • MOTOR Wet rotor type, with bearings lubricated by the pumped liquid. Axial and radial bearings made of ceramic. • Single-phase 230 V 50 Hz power supply. Terminal box axially integrated in the motor. • Three speed hand selector motor. • Insulation class 180 (H). • Protection class IP 44. • CONSTRUCTION CHARACTERISTICS Electric circulator pumps for sanitary hot water circulation, at a recommended maximum temperature of 65°C , maximum hardness of 25° f (14°dH) and maximum viscosity of 10 mm2/s. • Stainless steel pump body with 1”, 1” ¼ and 1” ½ threaded connections. • According to EN standards 60335-1, 60335-2-51, 55014-1, 55014-2. • ACCESSORIES • • Pipe unions. Insulation shell. INSTALLATION • Suitable for installation in horizontal or vertical piping, in any position provided that motor axis is horizontal. 3 TLCN SERIES IDENTIFICATION CODE TLC N 25 4 L PORT TO PORT DISTANCE NULL = 130 mm M =150 mm L = 180 mm MAXIMUM HEAD IN m. PORT NOMINAL DIAMETER N = STAINLESS STEEL VERSION SERIES NAME EXAMPLE : TLCN 25-4L TLC series circulator, stainless steel N version, port nominal diameter = 25, max head= 4 m, with port to port distance of 180 mm. TABELLA MATERIALI TLCB TABLE OF MATERIALS PART Pump body Impeller Shaft Inner jacket Wear ring Bearings Gaskets MATERIAL Stainless steel Composite material Ceramic Stainless steel Ceramic Ceramic EPDM tlcn-2p50-en_a_tm Regulations (EC) n. 641/2009 and (EU) n. 622/2012 – Annex I – point 2 (Product information requirements) a) Energy efficiency index: note not applicable to these products. b) “The benchmark for most efficient circulators is EEI ≤ 0,20”: note not applicable to these products. c) Information relevant for disassembly, recycling or disposal at end-of-life: observe the current laws and by-laws governing sorted waste disposal. Consult the product operating manual. d) Information for circulators specifically designed to potable water uses: ”This circulator is suitable for drinking water only”. 4 TLCN SERIES TABELLA DI PRESTAZIONI IDRAULICHE CIRCOLATORI SERIE TLCN HYDRAULIC PERFORMANCE TABLE CAPACITOR Q = DELIVERY PUMP MAXIMUM MAXIMUM TYPE ABSORBED ABSORBED l/s 0 0,2 0,3 0,4 0,5 0,7 0,8 1,0 1,2 POWER CURRENT m3/h 0 0,6 1,2 1,5 1,8 2,4 3,0 3,6 4,2 W A 27 32 35 33 39 44 43 65 80 0,12 0,14 0,15 0,14 0,17 0,19 0,19 0,28 0,34 230V 50Hz TLCN 15-2.5 TLCN 20-2.5M TLCN 25-2.5 TLCN 15-4 TLCN 20-4M TLCN 25-4 (L) TLCN 15-6 TLCN 20-6M TLCN 25-6 (L) μF V 1,5 400 1,5 400 2,0 400 SPEED H = TOTAL HEAD METRES COLUMN OF WATER 1 2 3 1 2 3 1 2 3 Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A) 5 2,1 2,3 2,5 3,5 3,9 4,1 3,4 5,1 6,2 2,0 2,1 2,3 2,7 3,2 3,5 2,3 4,1 5,5 1,5 1,7 1,9 1,8 2,5 2,8 1,5 3,0 4,7 1,3 1,5 1,7 1,4 2,1 2,5 1,1 2,5 4,3 1,0 1,2 1,4 1,1 1,8 2,1 0,9 2,0 3,9 0,8 1,1 1,4 1,1 3,0 2,1 1,2 tlcn-2p50-en_b_th TLCN SERIES SINGLE-PHASE OPERATING CHARACTERISTICS 0 4 2 6 4 Q [Imp gpm] 8 6 0 10 Q [US gpm] 8 0 2 4 2 4 6 6 10 Q [Imp gpm] 8 8 10 12 Q [US gpm] 5 16 H [ft] H [m] H [ft] 3,0 ISO 9906:2012 - Grade 3B H [m] 2 H [kPa] 0 TLCN 15 - 4 TLCN 20 - 4M TLCN 25 - 4 TLCN 25 - 4L ISO 9906:2012 - Grade 3B H [kPa] TLCN 15 - 2.5 TLCN 20 - 2.5M TLCN 25 - 2.5 14 25 2,5 8 40 4 3 12 3 20 2,0 2 2 6 10 3 1 1 15 1,5 30 8 4 20 2 6 10 1,0 4 2 10 1 5 0,5 0 0,5 1,0 0,0 1,5 0,2 0,4 TLCN 15 - 6 TLCN 20 - 6M TLCN 25 - 6 TLCN 25 - 6L 0 0 2 4 0 Q [m3/h] 2,5 0,6 Q [l/s] 0 0 0,0 0,0 ISO 9906:2012 - Grade 3B 4 2 2,0 6 6 8 8 10 10 12 12 14 Q 14[Imp gpm] 16 Q [US gpm] H [m] H [ft] 7 20 6 H [kPa] 0,0 A0029_A_CH 0,0 60 3 5 15 2 40 4 1 10 3 20 2 5 0 0 0 0,0 1 0,2 2 0,4 3 0,6 0,8 Q [m3/h] 4 1,0 Q [l/s] 0 A0031_A_CH 1 These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec. 6 0,5 1,0 0,2 1,5 0,4 2,5 Q [m3/h] 3,0 2,0 0,6 Q 0,8 [l/s] 0 A0030_A_CH 2 TLCN SERIES DIMENSIONS AND WEIGHTS DIMENSIONI E PESI CIRCOLATORI SERIE TLCN 2 poli 50 Hz DIMENSIONS AND WEIGHTS TABLE DIMENSIONS (mm) PUMP TYPE TLCN 15-2.5 TLCN 20-2.5M TLCN 25-2.5 TLCN 15-4 TLCN 20-4M TLCN 25-4 TLCN 25-4L TLCN 15-6 TLCN 20-6M TLCN 25-6 TLCN 25-6L WEIGHT H H1 D 130 150 130 130 150 130 180 130 150 130 180 65 75 65 65 75 65 90 65 75 65 90 ½" ¾" 1" ½" ¾" 1" 1" ½" ¾" 1" 1" F G 1" G 1"¼ G 1"½ G 1" G 1"¼ G 1"½ G 1"½ G 1" G 1"¼ G 1"½ G 1"½ DN kg 15 20 25 15 20 25 25 15 20 25 25 2,7 2,7 2,7 2,7 2,7 2,7 2,8 2,7 2,7 2,7 2,8 tlcn-2p50-en_a_td 7 8 Sanitary Circulators MARKET SECTORS SANITARY LIGHT COMMERCIAL. APPLICATIONS • Circulation of sanitary hot water in high flow/high head installations. TLCHN Series SPECIFICATIONS PUMP Flow rate: up to 12 m3/h. Head: up to 12 m. Temperature of pumped liquid: +2°C ÷ +110°C (recommended up to 65°C). Avoid condensation and ice formation. • Maximum operating pressure: 10 bar (PN 10). • Impeller: made of composite material. • Wear ring: ceramic. • • • MOTOR Wet rotor type, with bearings lubricated by the pumped liquid. Axial and radial bearings made of ceramic. • Single-phase 230 V 50 Hz power supply. Terminal box axially integrated in the motor. • Three speed hand selector motor. • Insulation class 180 (H). • Protection class IP 44. • CONSTRUCTION CHARACTERISTICS Electric circulator pumps for sanitary hot water circulation, at a recommended maximum temperature of 65°C , maximum hardness of 25° f (14°dH) and maximum viscosity of 10 mm2/s. • Stainless steel pump body with 1” ¼ and 1” ½ threaded connections. • According to EN standards 60335-1, 60335-2-51, 55014-1, 55014-2. • ACCESSORIES • • Pipe unions. Insulation shell. INSTALLATION • Suitable for installation in horizontal or vertical piping, in any position provided that motor axis is horizontal. 9 TLCHN SERIES IDENTIFICATION CODE TLC H N 25 8 L PORT TO PORT DISTANCE 180 mm MAXIMUM HEAD IN m. PORT NOMINAL DIAMETER N = STAINLESS STEEL VERSION H = HIGH FLOW / HIGH HEAD SERIES NAME EXAMPLE : TLCHN 25-8L TLC series circulator, high flow/head H version, stainless steel N version, port nominal diameter = 25, max head= 8 m, with port to port distance of 180 mm. TABELLA MATERIALI TLCHN TABLE OF MATERIALS PART Pump body Impeller Shaft Inner jacket Wear ring Bearings Gaskets MATERIAL Stainless steel Composite material Ceramics Stainless steel Ceramics Ceramics EPDM tlchn-2p50-en_a_tm Regulations (EC) n. 641/2009 and (EU) n. 622/2012 – Annex I – point 2 (Product information requirements) a) Energy efficiency index: note not applicable to these products. b) “The benchmark for most efficient circulators is EEI ≤ 0,20”: note not applicable to these products. c) Information relevant for disassembly, recycling or disposal at end-of-life: observe the current laws and by-laws governing sorted waste disposal. Consult the product operating manual. d) Information for circulators specifically designed to potable water uses: ”This circulator is suitable for drinking water only”. 10 TLCHN SERIES TABELLA DI PRESTAZIONI IDRAULICHE CIRCOLATORI SERIE TLCHN HYDRAULIC PERFORMANCE TABLE PUMP MAXIMUM MAXIMUM TYPE ABSORBED ABSORBED POWER CURRENT W A 220 228 260 260 270 286 283 343 357 285 372 400 1,03 1,04 1,13 1,23 1,24 1,25 1,35 1,44 1,56 1,36 1,69 1,73 230V 50Hz TLCHN 20-7L TLCHN 25-7L TLCHN 20-8L TLCHN 25-8L TLCHN 20-10L TLCHN 25-10L TLCHN 20-12L TLCHN 25-12L CAPACITOR Q = DELIVERY SPEED l/s 0 3 m /h 0 μF V 8,0 400 8,0 8,0 8,0 400 400 400 0,3 0,7 1,0 1,3 1,7 2,0 2,3 2,7 1,2 2,4 3,6 4,8 6,0 7,2 8,4 9,6 H = TOTAL HEAD METRES COLUMN OF WATER 1 2 3 1 2 3 1 2 3 1 2 3 Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A) 11 5,8 6,7 7,1 6,6 7,5 8,0 8,3 9,4 10,1 7,7 10,3 12,0 5,2 4,3 6,1 5,4 6,7 6,1 5,5 4,2 6,9 6,1 7,5 6,8 6,9 5,0 8,7 7,7 9,6 8,8 6,5 4,4 9,7 8,4 11,4 10,4 3,1 4,4 5,2 2,8 4,9 5,8 2,9 6,3 7,7 2,2 6,9 9,2 2,0 3,3 4,2 1,6 3,6 4,6 1,1 4,7 6,5 0,7 5,2 7,8 1,0 2,1 3,3 0,8 2,4 3,5 1,2 2,4 1,5 1,4 2,5 1,6 3,1 5,2 1,7 3,9 2,6 1,6 3,5 6,2 1,8 4,7 3,2 2,0 tlchn-2p50-en_a_th TLCHN SERIES SINGLE-PHASE OPERATING CHARACTERISTICS 10 30 20 Q [Imp gpm] 0 40 Q [US gpm] 30 H [m] 8 0 20 10 30 20 Q [Imp gpm] 40 Q [US gpm] 30 10 30 H [ft] 25 10 H [ft] 0 20 ISO 9906:2012 - Grade 3B H [m] 10 H [kPa] 0 TLCHN 20 - 8L TLCHN 25 - 8L ISO 9906:2012 - Grade 3B 80 8 20 6 H [kPa] TLCHN 20 - 7L TLCHN 25 - 7L 60 25 3 3 2 2 20 6 60 15 1 1 40 4 15 40 4 10 10 20 2 20 2 5 5 0,5 6 1,0 1,5 2,0 TLCHN 20 - 10L TLCHN 25 - 10L 0 0 Q [m3/h] 10 0 2,5 Q [l/s] 0 0 0,0 20 10 30 20 Q [Imp gpm] 4 0,5 6 1,0 0 40 Q [US gpm] 30 2 2,0 20 10 30 20 Q [Imp gpm] 40 Q [US gpm] 30 H [m] H [kPa] H [ft] H [m] 2,5 Q [l/s] 14 40 12 100 10 0 Q [m3/h] 10 ISO 9906:2012 - Grade 3B 10 0 12 8 1,5 TLCHN 20 - 12L TLCHN 25 - 12L ISO 9906:2012 - Grade 3B 10 0 8 A0033_A_CH 4 H [ft] 0,0 2 H [kPa] 0 0 A0032_A_CH 0 120 30 3 3 10 100 80 8 30 2 2 80 8 1 20 6 1 60 20 6 60 40 4 40 4 10 10 20 20 2 0 0 0,0 2 0,5 4 1,0 6 1,5 8 2,0 Q [m3/h] 10 2,5 Q [l/s] 0 0 A0034_A_CH 0 0 0 0,0 These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec. 12 2 0,5 4 1,0 6 1,5 8 2,0 Q [m3/h] 10 2,5 Q [l/s] 0 A0035_A_CH 2 TLCHN SERIES DIMENSIONS AND WEIGHTS DIMENSIONI E PESI CIRCOLATORI SERIE TLCHN 2 poli 50 Hz DIMENSIONS AND WEIGHTS TABLE DIMENSIONS (mm) PUMP TYPE TLCHN 20-7L TLCHN 25-7L TLCHN 20-8L TLCHN 25-8L TLCHN 20-10L TLCHN 25-10L TLCHN 20-12L TLCHN 25-12L WEIGHT H H1 D F DN kg 180 180 180 180 180 180 180 180 90 90 90 90 90 90 90 90 ¾" 1" ¾" 1" ¾" 1" ¾" 1" G 1"¼ G 1"½ G 1"¼ G 1"½ G 1"¼ G 1"½ G 1"¼ G 1"½ 20 25 20 25 20 25 20 25 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 tlchn-2p50-en_a_td 13 14 DOCUMENTATION 15 FURTHER PRODUCT SELECTION AND DOCUMENTATION XylectTM XylectTM is pump solution selection software with an extensive online database of product information across the entire Lowara, and Vogel range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date product information on thousands of products and accessories. The possibility to search by applications and the detailed information output given makes it easy to make the optimal selection without having detailed knowledge about the Lowara and Vogel products. The search can be made by: • Application • Product type • Duty point XylectTM gives a detailed output: • List with search results • Performance curves (flow, head, power, efficiency, NPSH) • Motor data • Dimensional drawings • Options • Data sheet printouts • Document downloads incl dxf files The search by application guides users not familiar with the product range to the right choice. 16 FURTHER PRODUCT SELECTION AND DOCUMENTATION XylectTM The detailed output makes it easy to select the optimal pump from the given alternatives. The best way to work with XylectTM is to create a personal account. This makes it possible to: • Set own standard units • Create and save projects • Share projects with other XylectTM users Every user have a My Xylect space, where all projects are saved. For more information about XylectTM please contact our sales network or visit www.xylect.com. Dimensional drawings appear on the screen and can be downloaded in dxf format. 17 18 Xylem |’zīl m| e 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We’re approximately 12,500 people unified in a common purpose: creating innovative solutions to meet our world’s water needs. Developing new technologies that will improve the way water is used, conserved, and reused in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to xyleminc.com. Legal head office Xylem Water Solutions Italia Srl For information and technical support Xylem Service Italia Srl Via Gioacchino Rossini 1/A 20020 – Lainate (MI) - Italy Tel. (+39) 02 90358.1 Fax (+39) 02 9019990 www.xylemwatersolutions.com Via Dottor Vittorio Lombardi 14 36075 - Montecchio Maggiore (VI) - Italy Tel. (+39) 0444 707111 Fax (+39) 0444 491043 www.lowara.com Xylem Water Solutions Italia Srl reserves the right to make modification without prior notice. Lowara, Xylem are trademarks of Xylem Inc. or one of its subsidiaries © 2014 Xylem, Inc.