FREQUENCY DOMAIN ANALYSIS OF OFFSHORE PILES
Transcription
FREQUENCY DOMAIN ANALYSIS OF OFFSHORE PILES
a Frequency Domain Dynamic Analysis to Assess the Structural Integrity of Large Diameter Foundation Piles during Offshore Installation using GT STRUDL and GT SELOS Loic Faure and Dr Arash Parsa June 2013 Offshore Pile Installation Operations 72 to 102’’ Diameter Piles with WT of 60 to 100mm – 60 to 110m Lg Piles Pile driving with heavy hydraulic hammers (up to 550Te) in a difficult environment (Offshore North Sea) Pile Only Pile + Hammer above Wave Zone Pile + Hammer in Wave Zone Pile + Hammer below Wave Zone a d 25th Annual GT STRUDL Users Group Meeting June 2013 Pile Driven to Target Penetration Goal of the Analysis Ensuring pile integrity at each stage of the installation Minimising weather down time during offshore installation Producing clear guidelines on the acceptable sea states (combination of significant wave height (Hs) and period (Tz)) for driving operations Pile Utilisation Factor (UF) > 1.0 Driving is not allowed Pile Utilisation Factor (UF) < 1.0 Driving is allowed Allowable Dynamic Driving Stress is 131 MPa a d 25th Annual GT STRUDL Users Group Meeting June 2013 Codes of Practice Requirements Codes of Practice: API RP2A, ISO 19902, Norsok N004.. Waves Mean Sea Level Pile Oscillations Beam-Column Check at the Critical Section(s) (Usually at the upper shim, sometimes at sections with changes in pile wall thickness) P-Delta Moment to be included Hammer Current Pile Sum of Driving Stresses + Axial & Bending Stresses < Yield Stress Axial Force Bending Moment Upper Shim Lower Shim a d 25th Annual GT STRUDL Users Group Meeting June 2013 Mud Line Overview of the Analysis Based on Frequency Domain Dynamic Analysis Use of a GT STRUDL beam model Dynamic Base Shear Static Base Shear GT SELOS GT STRUDL / GT SELOS Wave Induced Bending Moment (P-∆ Analysis) GT STRUDL / GT SELOS Dynamic Amplification Factor Wave Design Spectrum Bending Moment RAO Bending Moment Spectral Density Total Bending Moment and Axial Force Buckling Factor Code Check GT STRUDL Operability Table a d 25th Annual GT STRUDL Users Group Meeting June 2013 Dynamic Driving Stress Vs. Hammer Mechanical Efficiency Setting FOUNDATION DEPARTMENT GT STRUDL and GT SELOS Facilities Used SPREADSHEET •Generate the Sea Spectral Density (function of Hs and Tz) GT STRUDL •Eigen Value SPREADSHEET GT SELOS •Added Mass due to Entrapped Water •Wave and Current Loading Generation •Wave Motion Time History Analysis SPREADSHEET GT STRUDL •P-Delta Analysis GT SELOS •Wave and Current Loading Generation SPREADSHEET GT STRUDL •Buckling Analysis a d 25th Annual GT STRUDL Users Group Meeting June 2013 Interaction with Excel Use of the COUTPUT command to export the relevant GT STRUDL / GT SELOS output to a text file and extracted with a spreadsheet including a macro (using VBA) Typical GT STRUDL Input Data extracted and sorted out in the required format in a spreadsheet automatically Typical GT STRUDL Output Typical VBA Macro a d 25th Annual GT STRUDL Users Group Meeting June 2013 Computing the DAF Two models are run with GT SELOS to calculate the base shear ‘Pseudo’ static model: unit amplitude waves (of varying periods) are stepped through the structure (with no modal information) and the maximum static base shear is extracted Dynamic model: unit amplitude waves (of varying periods) are stepped through the structure and a time motion history analysis is used to calculate the maximum dynamic base shear a d 25th Annual GT STRUDL Users Group Meeting June 2013 Calculating the Natural Period of the Pile + Hammer First step is to calculate the entrapped water in the pile by using the added mass generation command with GT SELOS. An output file xx.AMG is generated. $ EXECUTE ADDED MASS GENERATION $ INERTIA JOINTS ADD INCLUDE MEMBER FLOOD MASS $ AXIAL MASS EXCLUDED Second step is to calculate the eigen values. An output file (STDBX13) containing all the modal information is created. $$***REFERENCE INPUT FILE*** CINPUT ‘xx.AMG' $$************************** EIGEN PARAMETERS SOLVE USING GTLANCZOS NUMBER OF MODES 25 DYNAMIC ANALYSIS EIGEN LIST DYNAMIC EIGENVALUES LIST DYNAMIC PARTICIPATION FACTORS WRITE REPLACE DYNAMIC DATA FOR SELOS a d 25th Annual GT STRUDL Users Group Meeting June 2013 Output File from Wave Loading Typical GT SELOS Input ‘Static’ Base Shear for a given wave period and a unit wave amplitude a d 25th Annual GT STRUDL Users Group Meeting June 2013 Output File from Wave Motion Time History Analysis GT SELOS uses of a modified Morison’s equation to account for hydrodynamic damping in addition to the structural damping Dynamic Base Shear for a given wave period and increasing wave heights Typical GT SELOS Input a d 25th Annual GT STRUDL Users Group Meeting June 2013 Calculating the DAF using GT SELOS Output A spreadsheet including macro is used to extract the static base shear and dynamic base shear from the output files and to calculate the DAF. DAF = Dynamic Base Shear / Static Base Shear Dynamic base shear is linear with the wave amplitude except for wave periods close to the pile natural periods. Dynamic base shear is interpolated using a polynomial equation (typically 2nd or 3rd order) when necessary. The DAF can then be plotted as a function of the wave period (for any sea state). a d 25th Annual GT STRUDL Users Group Meeting June 2013 Non Linearity of the DAF at the natural period Because the DAF is a function of the wave amplitude, the DAF will vary with the sea spectral density. a d 25th Annual GT STRUDL Users Group Meeting June 2013 Wave Induced Bending Moment (including P-Delta Analysis) The wave loadings (from GT SELOS) for a unit wave amplitude over a range of periods are used to perform a large deflection (P-Delta) analysis of the pile and hammer with GT STRUDL. Typical GT STRUDL Input Waves Still Water Wave Induced Mean Deflection Deflection Mean Deflection Hammer Hammer Current Current Pile Mean Axial Force Mean Bending Moment a Pile Mean + Wave Induced Axial Force d 25th Annual GT STRUDL Users Group Meeting June 2013 Mean + Wave Induced Bending Moment Wave Induced Bending Moment (including P-Delta Analysis) The output from the P-Delta analysis (bending moment in the critical section(s) of the pile) is stored in a text file (using the COUTPUT COMMAND) and extracted with a spreadsheet including a macro. Bending Moment values for waves of unit amplitude and varying period The wave induced bending moment is then plotted against the wave period (for a unit wave amplitude). a d 25th Annual GT STRUDL Users Group Meeting June 2013 Linearity of the Wave Induced Bending Moment The frequency domain analysis approach is only possible because the wave induced bending moment is linear with the wave height despite the fact that a non-linear (P-Delta) analysis is performed to calculate the wave induced bending moment. The bending moment in the pile is a linear function of the wave height (because the wave only generates lateral loads on the pile) and a nonlinear function of the hammer weight (which is not a variable for the analysis). This has been checked by performing a sensitivity analysis with GT STRUDL varying the hammer weight and wave height for a number of P-Delta analysis. a d 25th Annual GT STRUDL Users Group Meeting June 2013 Response Amplitude Operator (RAO) of the Bending Moment The RAO of the bending moment is the product (squared) of the DAF Curve and the Wave Induced Bending Moment Curve. GT STRUDL GT SELOS GT STRUDL GT SELOS Because the RAO is built using the DAF curve, one should keep in mind that the RAO is also a function of the sea state considered. a d 25th Annual GT STRUDL Users Group Meeting June 2013 Calculating the 3Hrs Maximum Bending Moment Sea Spectral Density (function of Hs and Tz) Bending Moment Spectral Density A = Area under the Curve 10800 3hr Maximum Bending Moment = 2 * 0.5 ln Tz Total Bending Moment (used for code check) = Mean Bending Moment + 3hr Maximum Bending Moment a d 25th Annual GT STRUDL Users Group Meeting June 2013 * A Buckling Analysis Applicable K-Factor for a straight cantilever is 2. For pile installation, most codes recommend to use a value varying from 2.1 to 2.4. This is correct when self weight of the column is negligible compared to the applied compressive load. However the pile can be as heavy as the hammer during the initial stages of driving (leading to a K-factor < 2) The applicable K-factor can be assessed by performing a linear buckling analysis with GT STRUDL. Typical GT STRUDL Input a d 25th Annual GT STRUDL Users Group Meeting June 2013 Buckling Analysis Vs P-Delta Analysis The load multiplier obtained from the linear buckling analysis was checked by calibrating the buckling analysis against text book cases and by performing an additional P-Delta Analysis. P-Delta analysis is carried out for increased loads and the deflection at the tip of the pile is plotted against the applied load. When the critical load is reached the P-Delta analysis can not converge anymore. The buckling and P-Delta analyses give the same k-factor a d 25th Annual GT STRUDL Users Group Meeting June 2013 Final Step : Code Check of the Pile The code check of the pile is performed using a spreadsheet including a macro which iterate the code check for all the sea states (combination of significant wave height (Hs) and period (Tz)) to be considered (typically about 60 combinations). The spreadsheet also derives the hammer energy setting not to be exceeded to ensure pile integrity. This analysis has to be repeated for each pile penetration deemed critical and for the different hammers that could be used for the operations. a d 25th Annual GT STRUDL Users Group Meeting June 2013 Example Key Parameters Key GT STRUDL / SELOS Outputs Demonstration of spreadsheets a d 25th Annual GT STRUDL Users Group Meeting June 2013 Further Points and Possible Improvements In addition to the internal forces and moments, a number of variables can be calculated using the same approach: pile tip deflection and acceleration, lateral reaction on the pile sleeve. The spreadsheet allows to use a number of sea spectral density formulations, including multi-directional spectrums. The analysis could be fully automated by writing a macro generating the input files for GT STRUDL and GT SELOS and making use of the batch run option offered by GT STRUDL. The frequency domain analysis approach relies entirely on the linearity of the system and therefore this has some limitations. Problems with nonlinear boundary conditions can not be analysed using a frequency domain analysis (gap of the pile sleeve, or pin piles being driven directly into the soil without a pile sleeve). a d 25th Annual GT STRUDL Users Group Meeting June 2013 Questions Any Questions? a d 25th Annual GT STRUDL Users Group Meeting June 2013