Corning_copper (PDF 10,6 MB)

Transcription

Corning_copper (PDF 10,6 MB)
Corning Cable Systems
Solutions for Premises Networks
Copyright © 2005
All rights reserved. This publication must not be reproduced or copied in any
way whatsoever without the express consent in writing of Corning Cable
Systems GmbH & Co. KG. All Corning Cable Systems products described in
this catalog are subject to availability and technical modification. Corning
Cable Systems GmbH & Co. KG reserves the right to improve, enhance or
otherwise modify Corning Cable Systems product without prior notification,
including and in particular technical data and other information about such
products. There is no legal obligation to supply a specific product to a precise
specification until a binding order is accepted by Corning Cable Systems
GmbH & Co. KG.
Order No. EUR-221-EN
Printed in Germany
Corning Cable Systems GmbH & Co. KG
Rotherstrasse 21
10245 Berlin, Germany
LANscape® Solutions FutureCom™ Copper Products
Corning Cable Systems
LANscape® Solutions
FutureCom™ Copper Products Catalog
Issue 1, EMEA
Corning
Cable Systems
FutureCom E System
55
5
FutureCom D System
81
6
FutureCom UE System
101
7
FutureCom UD System
115
8
Hardware
127
9
Telephone / ISDN Products
165
10
Cable for Patch Cords
169
11
Industrial Cable
175
12
Special Cable
183
13
Further Information
205
Corning Cable Systems
1
FutureCom F
4
FutureCom 10TEN
41
FutureCom E
FutureCom 10 TEN System
FutureCom D
3
FutureCom UD FutureCom UE
13
Hardware
FutureCom™ F System
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
2
Industrial
Cable
3
Special
Cable
Introduction
Further
Information
1
Introduction
Table of contents
LANscape and UniCam are registered trademarks of Corning
Cable Systems Brands, Inc. FutureCom, FutureLink, Pretium,
FutureCom 10TEN, LSZH and Plug & Play are trademarks of
Corning Cable Systems Brands, Inc. Discovering Beyond
Imagination is a registered trademark of Corning
Incorporated. All other trademarks are the properties of
their respective owners. Corning Cable Systems is ISO9001
and ISO 14001 certified.
2
Corning Cable Systems
4
1.2. Corning Quality
5
1.3. Corning Cable Systems Global Locations
6
1.4. Standards for Structured Cabling
8
1.5. System Description
9
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
1.5.1. LANscape® Structured Cabling
FutureCom F
1.1. Corning - A Reliable Partner
FutureCom 10TEN
3
FutureCom E
Introduction
Further
Information
1
Introduction
Table of contents
Corning Cable Systems
3
Corning Quality
Corning Incorporated is a diversified technology company
Corning’s own complete system for structured cabling, on
with a proud history of developing breakthrough technolo-
the basis of copper cable, followed in 1990. Since then, Corn-
years, integrating scientific discovery with market need. We
world, Corning started using 600 MHz technology for sym-
gies that significantly improve people’s lives. We have been
changing the world through innovation for more than 150
focus on high-impact growth opportunities in the telecommunications, flat panel display, environmental, life sciences
and semiconductor industries.
Corning is a reliable partner that meets the communication
requirements of its customers all over the world with costeffective solutions.
In 2000 Corning grouped all its cable, hardware and equipment businesses into the Corning Cable Systems division.
Corning Cable Systems now comprises the former Siecor
Corporation, the communication cables business from BICC
(Corning Cables), Siemens’ former Communication Cables
division and RXS Kabelgarnituren. Norddeutsche Seekabelwerke (NSW) also belongs to Corning Incorporated and is
continuing to operate as a separate company.
ing has always been a market leader and the technology
leader for cabling systems. In 1995, for the first time in the
metrical copper cabling systems.
Today, with LANscape® FutureCom™, Corning offers a com-
plete system of copper components with bandwidths of 100
to 1500 MHz and the experience of installing more than
15 million ports. This can also be combined with modular
fiber optic hardware and FutureCom™ cable components.
LANscape - the combination of FutureCom™ copper and
fiber optic products - thus offers the optimal solution for
every network.
Our quality and environmental management systems are
certified to DIN EN ISO 9001 and ISO 14001. Our global pres-
ence is your gain because, wherever you are, Corning is close
at hand.
In the field of fiber optic cable technology, Corning was one
of the original pioneers, with expertise second to none. As
early as 1974, when fiber optic technology was still in its in-
fancy, Corning was working with Europe’s leading Public
Telecommunications companies in developing trial fiber optic routes. The end of the 90s saw the beginning of local
networks on the basis of today’s network protocols - and
Corning was actively involved from the start.
4
Corning Cable Systems
Further
Information
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
FutureCom 10TEN
Corning Cable Systems is committed to providing excellent product
Corning Cable Systems
5
Introduction
quality and customer support services.
FutureCom F
Corning Quality
Corning Cable Systems Global
Cable and Hardware Businesses
Whiston, Great Britain
Derby, Great Britain
Aberdeen,
Great Britain
Deeside,
Wales
Headquarter,
Hickory NC,
USA
Favières, France
Winston-Salem,
NC, USA
Keller, TX, USA
Santo Domingo,
Dominican Republic
Reynosa,
Mexico
Rio Grande,
Puerto Rico
Boca Raton,
FL, USA
6
Corning Cable Systems
Madrid,
Spain
Hagen,
Germany
Nordenham,
Germany
Berlin,
Germany
Neustadt,
Germany
Lodz,
Poland
Munich,
Germany
Turin, Italy
Hickory, North Carolina, USA.
Corning Cable Systems EMEA Headquarters is located in
FutureCom E
FutureCom 10TEN
FutureCom F
Berlin, Germany.
Introduction
Corning Cable Systems Global Headquarters is located in
FutureCom D
Moscow,
Russia
FutureCom UD FutureCom UE
Gebze, Türkei
Tokyo, Japan
Amman,
Jordan
Bangkok,
Thailand
Shanghai,
China
Makati City,
Phillipines
Kuala Lumpur,
Malaysia
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
Singapore,
Singapore
Further
Information
Special
Cable
Industrial
Cable
Clayton,
Australia
Corning Cable Systems
7
Standards for Structured Premises
Cabling Solutions
The requirements of future-proof and flexible structured cabling are largely determined by three fundamental cabling
standards addressing specific geographic regions:
Standard
Europe
North America
World
Description
EN 50173-1 (2003) Cabling Standard Information Technology
Generic Cabling Systems
TIA/EIA 568 B. 1 (2001) / B.2 1 (2001) Commercial Building Telecommunications
Cabling Standard
ISO/IEC 11801 Edition 2002 Cabling Standard, Generic Cabling for
Customer Premises
The TIA/EIA is not a standard as such, but an industry specification in the North American market. It also contains
requirements regarding the transmission characteristics of cabling and components that differ from those of the EN or ISO/
IEC. It has its origins in the specification of unshielded copper components.
Campus
Building
distributor
distributor
Fiber
1500 m
Campus Backbone
8
Floor
distributor
Fiber (copper)
500 m
Telecommunication
Building Backbone
outlet
Copper / Fiber
Copper / Fiber
90 m
Horizontal Substystem
100 m incl. patch and connecting cords
Corning Cable Systems
Terminal
equipment
LANscape® Structured Cabling
Building cabling can utilize cabling with both symmetrical copper cables and components and fiber optic cables and
one location with each other. The campus distributor forms
The cabling is installed in a star shape radiating out from
the center of primary cabling. Due to the relatively long
transmission paths, only fiber optic cabling is worth considering. Corning offers a fiber optic modular cabling solution
which can be combined with copper-component cabling systems. For the campus environment, mainly single-mode
fiber cable is used, which distinguishes itself by its low at-
tenuation and high bandwidth. A further argument for fiber
optic cable in this area is its electromagnetic insensitivity.
Building Backbone
In the horizontal subsystem, mainly copper cable is used.
the horizontal distributor to the individual connection
boxes. The distance, however, should not exceed 90 m, since
the cabling would then no longer comply with the standard.
An additional option in the horizontal area is “fiber to the
desk” (FTTD), i.e. fiber optic cabling to the workstation. This
is used for high bandwidth or long distance centralized
cabling applications.
FutureCom UD FutureCom UE
Campus cabling (backbone) links the individual buildings in
FutureCom E
Horizontal Subsystem
FutureCom D
Campus Backbone
FutureCom 10TEN
FutureCom F
Introduction
components. In the primary area, only fiber optic cables and components are used.
The connection between the building distributor and the
various horizontal distributors is designated as the second-
ary area. It represents the backbone of the building. The cabling of the vertical area can be carried out with both symmetrical copper cables and fiber optic cables. “High-end”
copper data cable (bandwidths up to 1500 MHz), such as
Hardware
those you can find in the Corning FutureCom™ product
range, can also be used in the secondary area for lengths up
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
to 100 m.
For increased bandwidth requirements, fiber optic cables
(generally multi-mode fiber cables) are recommended in
Further
Information
Special
Cable
Industrial
Cable
this area for greater future security .
Corning Cable Systems
9
LANscape® Structured Building Cabling
Horizontal Subsystem:
FutureCom™ Outlets and Outlet Accessories
(see pages 128-143)
10
Corning Cable Systems
Horizontal Subsystem:
FutureCom Data Cables S/FTP, F/FTP, SF/UTP, F/UTP
or UTP
(see system chapters in this catalog)
Introduction
FutureCom F
Horizontal Subsystem:
FutureCom Floor Distributors
19“ Patch Panels
(see pages 152-156 or the LANscapeFiber Optic
Campus Backbone – Backbone Cabling:
Fiber Optic Cables
(see the LANscape Fiber Optic Catalog,
Building Backbone – Vertical Area Cabling:
(see pages 152-156 or the LANscape® Fiber Optic
in this catalog)
FutureCom 19“ Distribution Panels
or 19“ Patch Panels
Catalog, EUR-220-EN)
Fiber Optic Cable or FutureCom S/FTP, F/FTP, SF/UTP, F/UTP
(see the LANscape Fiber Optic Catalog or system chapters
Corning Cable Systems
11
Further
Information
Building Backbone – Horizontal Distributor:
Special
Cable
Industrial
Cable
EUR-220-EN)
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
Catalog, EUR-220-EN)
FutureCom D
Campus Backbone – Building Distributor:
FutureCom E
FutureCom 10TEN
(see pages 144-151)
12
Corning Cable Systems
2.4.1. S1200 Modules and Connectors Overview
21
2.4. Connecting Hardware
2.4.2. Modules and Module Accessories
22
2.4.4. Tools
25
23
2.4.3. S1200 Connectors
2.5. Hardware
2.5.1. Outlets and Outlet Accessories
26
2.5.2. Floor Box Solutions
29
2.5.4. Consolidation Point Housing for S1200 Module
32
2.6.1. Cat. 7 Patch Cords
33
2.5.3. Patch Panels
31
2.6. Patch Cords
2.6.2. Cat. 6 Patch Cords
34
2.6.4. UTP Flex Patch PVC Cords
37
2.6.3. Cat. 5 Patch Cords
35
2.6.5. TV Connecting Cable
38
2.7. Plug & Play™
39
40
Special
Cable
2.8. Test Adapter Cable
FutureCom F
18
FutureCom 10TEN
2.3.1. Cat 7. S/FTP 1500/22 and S/FTP 1200/22 Cables
FutureCom E
2.3. Cable
FutureCom D
17
FutureCom UD FutureCom UE
2.2. Certificates
Hardware
14
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
2.1. System Descriptions & Data
Industrial
Cable
FutureCom F
Further
Information
2
Introduction
Table of contents
Corning Cable Systems
13
FutureCom™ F System
FutureCom F (2002) is Corning’s high-end system solution for symmetrical copper cabling. It satisfies all the requirements of
the current ISO/IEC 11801 (2002) and EN 50173-1 (2003) standards for Class F links and Category 7 for the components. The
FutureCom F System is part of the Pretium™ Solutions family. Pretium Solutions is Corning Cable Systems’ high preformance
solution set for fiber and copper premises networks.
Face Plate
“DELTAprofil”,
80x80 mm
WAXWSE-00001-C001
and S1200 Frame Set,
for two
S1200 Modules, Cat.7,
inclined,
CAXFSE-S0201-C001
SF/UTP flex/26, gray,
1xS1200/2 and
1xRJ45 connector,
2 pairs,
for 10/100Base-T
CCAFGD-D1024-A030-C1
FutureCom
S/FTP 1200/22
CCXFCB-L0047-C001-L7
S1200 Module,
1xS1200, shielded,
Cat. 7
CAXFSM-00100-C001
S1200 19“ Patch Panel,
for max. 24 S1200
Modules,
with integrated cable
strain relief, 1 U,
front panel of
high-grade steel
CAXFSV-02400-C001
S/FTP flex/26, rot,
1xS1200/4 and
1xRJ45- connector,
4 pairs, for
10/100/1000 Base-T
CCAFGB-G5021-A020-C0
SF/UTP flex/26, gray,
Cat.7, 2xS1200/2
connectors, 2 pairs
CCAFGB-G1026-A020-C1
The highest level of system performance up to 10GBase-T for
The FutureCom F system offers technical transmission
The resulting performance and future security guaranty the
addition, it enables the optimal utilization of cabling
FutureCom F cabling conforms with the standards and is
The performance of the FutureCom F cabling system has
the complete link is achieved through the utilization of
high-quality Category 7 cables, connectors and patch cords.
maximum level of investment protection for cabling.
outstandingly well suited for all recognized standardized
voice and data transmission procedures. This applies to analog voice transmission, ISDN, Token Ring, Ethernet (10-BaseT), Fast Ethernet (100Base-TX), Gigabit Ethernet, 10 Gigabit
Ethernet, 100Base-VG and ATM.
14
possibilities similar to those of optical cabling systems and
permits multimedia applications, such as TV transmission. In
through the use of 2-pair patch cords (cable sharing).
been certified by an independent testing body (see certificate). Of course, all EMC values standardized in Europe are
observed.
Corning Cable Systems
ACR in dB (typ. FutureCom F values)
Min. ELFEXT in dB*
ELFEXT in dB (typ. FutureCom F values)
Min. return loss in dB*
Return loss in dB (typ. FutureCom F values)
* According to ISO/IEC 11801 (2002)
61.0
5.3
–
102.1 93.7
65.0
–
7.5
–
88.5
–
103.0 95.0 91.0
19.0
21.0
–
21.0
–
–
21.0
–
13.4
–
75.6
–
100
20.8
17.1
155.5 250
33.8
–
21.4
62.9 –
42.1
21.0
–
56.9
23.1
68.9 60.6 50.5
–
44.4 –
83.0 79.0 74.0
–
27.5
12.0
21.0
21.0
–
37.8
600
54.6
43.5
51.2
19.0
52.3
1000 1200
–
–
57.6
68.0 60.0 58.0
24.5
–3.4
31.3
68.0 54.0
8.0
850
–
8.0
16.0
–
7.7
–
45.0
–
15.0
–
–
0.4
–
41.0
–
14.0
–
69.2
53.0
–
–
–
30.0
–
10.0
–
FutureCom D
The system values cited only apply to the use of original FutureCom F products. Derived values, such as PSACR, PSNEXT,
PSELFEXT, are in observance of the standard values, but are not shown.
FutureCom F
Min. ACR in dB*
65.0
62.5
–
FutureCom 10TEN
104.0 99.0 96.0 89.0 86.0 82.0 78.0
Min. NEXT in dB*
1.9
20
–
FutureCom E
NEXT in dB (typ. FutureCom F values)
Attenuation in dB (typ. FutureCom™ F values)
10
–
Attenuation and
Near-end Crosstalk (NEXT)
NEXT in dB
(typ. FutureCom F values)
min. NEXT in dB
According to standard
max. Attenuation in dB
According to standard
Attenuation in dB
(typ. FutureCom F values)
Further
Information
Special
Cable
Industrial
Cable
Frequency in MHz
FutureCom UD FutureCom UE
Max. attenuation in dB*
1
4.0
Hardware
Frequency in MHz
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Electrical Characteristics (at 20°C)
Introduction
FutureCom™ F System Data
for Channel Class F (2002)
Corning Cable Systems
15
FutureCom™ F System Data
for Channel Class F (2002)
Far-end Crosstalk Relating
to the Far End (ELFEXT)
ELFEXT in dB
(typ. FutureCom™ F values)
Min. ELFEXT in dB
According to standard
Frequency in MHz
Return Loss
Return loss in dB
(typ. FutureCom F values)
min. Return loss in dB
According to standard
Frequency in MHz
Test Setup
FutureCom F F/STP flex/26 Test Adapter Cable, 2 m
S1200 Module
90 m FutureCom F/STP 1200/22
S1200 Patch Panel 19“
FutureCom F F/STP flex/26 Test Adapter Cable, 2 m
16
Nominal intrinsic impedance
100 V
Max. DC loop resistance (according to standard)
40 V
Max. delay (according to standard)
0.05 µs
DC loop resistance
(typ. FutureCom F values)
Max. delay (according to standard)
Corning Cable Systems
15 V
, 0.02 µs
Further
Information
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
FutureCom 10TEN
FutureCom F
Introduction
FutureCom™ F Certificates
Corning Cable Systems
17
FutureCom™ F Cat.7 + Cables
S/FTP 1500/22 and S/FTP 1200/22
Braided shield
Halogen-free sheath,
flame retardant
Twisted pair
Foil shielding (PiMF)
4 shielded pairs
PE foam-skin insulation
Copper conductor
AWG 22
Application
The FutureCom™ S/FTP 1500/22 and S/FTP 1200/22 cables
are designed for applications up to 1500/1200 MHz. Their
transmission characteristics significantly exceed the requirements defined by today’s Category 7 specifications
(EN50288).
FutureCom cables are low-skew products, i.e. the skew
between the individual pairs is very low. This is increasingly
required for applications above 1 Gigabit Ethernet. The possibility of using the cable up to the GHz area enables the
highest possible transmission rates for multimedia applications such as TV transmission, in future-proof networks.
Each pair is individually foil shielded (FTP). The stranded
pairs (PiMF) are also sheathed with a braid shield (S/FTP),
which guarantees outstanding shielding characteristics. The
Mechanical Characteristics
Conductor insulation
cable satisfies Class B interference radiation standards
(EN 55022), as well as immunity (EN 55024), which enables
the realization of CE-compatible networks.
Halogen-free
Foam-skin material
Outer jacket
Halogen-free,
Temperature range (installation)
0 to +50°C
Area/range of application
Operating temperature
Min. bending radius
for one-time bending
Min. bending radius during
installation
Copper conductor
18
flame retardant
Dry and damp rooms
-20 to +60°C
>_ 45 mm (for 2x (4x2...)
over flat side)
>_ 65 mm (for 2x (4x2...)
over flat side)
AWG 22
Features
Specified up to 1500 MHz / 1200 MHz
Outstanding electrical characteristics
Each pair is shielded (PiMF)
Full copper braid shield
Streamlined design
Lightweight
Low skew between the pairs
Halogen-free (LSZH)
Fire retardant according to IEC 60332-3, Category C
Non-corrosive according to IEC 60754-2 (FRNC)
Low smoke according to IEC 61034
Corning Cable Systems
FutureCom™ F Cat.7 + Cables
S/FTP 1500/22 and S/FTP 1200/22
Introduction
>5000 MV x km
125 V +/– 20 %
>46 dB at 64 kHz
Propagation velocity
0.77 x c for S/FTP 1200
FutureCom 10TEN
<2 m V/m at 10 MHz
Surface transfer impedance
>40 dB at 1 MHz
Unbalance to ground dB/BZL = 100 m
>20 dB at 100 MHz
Unbalance to ground dB/BZL = 100 m
FutureCom E
0.76 x c for S/FTP 1500
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
4.2 ns/m
6 ns/100 m
Delay skew
Electrical Characteristics (at 20°C) for S/FTP 1500/22
Frequency in MHz
1
10
16
31.25
62.5
100
300
600
NEXT in dB at 100 m *
80.0
80.0
80.0
80.0
75.1
72.4
65.3
60.8
Attenuation in dB/100m *
Typical values dB/100m
Typical values in dB at 100 m
PSNEXT in dB at 100 m *
Typical values in dB at 100m
ELFEXT in dB at 100 m *
Typical values in dB at 100m
PSELFEXT in dB at 100 m *
Typical values in dB at 100m
ACR in dB
2.0
1.7
5.7
5.3
7.2
6.8
10.1
9.7
77.0
102.0
80.0
96.0
77.0
93.0
103.3
77.0
102.0
74.0
96.0
71.0
93.0
99.7
Frequency in MHz
1
10
NEXT in dB at 100 m *
80.0
80.0
Typical values dB/100m
13.8
77.0
102.0
69.9
96.0
66.9
93.0
98.2
77.0
102.0
64.1
93.0
61.1
90.0
95.3
2.0
5.7
16
7.2
20
8.1
72.5
102.0
58.1
88.0
55.1
85.0
91.2
PSELFEXT in dB at 100 m *
77.0
ELFEXT in dB at 100 m *
Typical values in dB at 100m
Typical values in dB at 100m
ACR in dB
1.6
4.9
6.4
80.0
74.0
69.9
68.0
64.1
94.0
94.0
94.0
94.0
91.0
96.0
103.3
96.0
71.0
100.1
96.0 93.0
66.9 65.0
98.6
98.0
69.4
102.0
54.0
82.0
51.0
79.0
87.5
10.1
Typical values in dB at 100m
PSNEXT in dB at 100 m *
17.5
31.25
7.0
9.0
80.0
80.0 80.0
>105.0
>105.0 >105.0 >105.0
>105.0
77.0
77.0
77.0 77.0
77.0
103.0 103.0 103.0 103.0 103.0
Typical values in dB at 100 m
18.5
33.3
30.8
>105.0 >105.0 >105.0 >105.0 >105.0 >105.0 103.0
Electrical Characteristics (at 20°C) for S/FTP 1200/22
Attenuation in dB/100m *
14.5
93.0
61.1
96.0
62.3
48.9
44.0
95.0
57.8
100.0 92.0
44.5
68.0
41.5
5.0
72.2
38.4
55.0
35.4
52.0
51.0
1000
57.8
–
85.0
–
82.0
37.0
–
34.0
–
27.2
62.5
100
300
600
75.1
72.4
65.3
60.8
14.5
12.8
18.5
16.5
33.3
28.9
>105.0 >105.0 102.0
72.5
103.0
58.1
88.0
55.1
86.0
92.2
69.4
103.0
54.0
82.0
51.0
80.0
88.5
62.3
48.9
47.1
95.0
57.8
100.0 93.0
44.5
70.0
41.5
68.0
73.1
38.4
55.0
35.4
53.0
53.3
1200
63.6
–
80.0
–
77.0
31.0
–
28.0
–
16.4
1500
72.0
–
75.0
–
72.0
24.0
–
21.0
–
3.0
1000 1200
54.5
–
85.0
–
83.0
40.0
–
38.0
–
30.5
59.8
–
80.0
–
78.0
35.0
–
33.0
–
20.2
* Standard: Requirements for 100 m installed Category 7 cable for Class F cabling sections (complies with EN 50288-4-1 and
IEC 61156-7)
Corning Cable Systems
FutureCom D
Unbalance to ground dB/BZL = 1000 m
100 V +/– 25 %
Impedance Zo at 251 - 600 MHz
FutureCom UD FutureCom UE
100 V +/– 18 %
Hardware
Impedance Zo at 101 - 250 MHz
FutureCom F
100 V +/– 15 %
Impedance Zo at 1 - 100 MHz
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Impedance Zo at 0.064 MHz
Industrial
Cable
Insulation resistance
1%
19
Special
Cable
Largest resistance margin
Further
Information
Electrical Characteristics (at 20°C)
FutureCom™ F Cat.7 + Cables
S/FTP 1500/22 and S/FTP 1200/22
Ordering Information
Type designation
Max.
Outer [ Weight Length
Fire Load Halogen- Tensile
Category No. of Pairs (MJ/m) free
Strength(N) (mm) (kg/km) (m)
Order Number
S/FTP 1500/22 8P
7+
S/FTP 1500/22 4P
S/FTP 1200/22 4P
S/FTP 1200/22 8P
20
7+
4
0.67
Yes
179
7.7
7+
8
1.34
Yes
358
7.7x16.5 133
7+
8
4
1.34
0.67
Yes
Yes
358
179
Corning Cable Systems
66
7.7x16.5 133
7.7
66
1000
CCXFCB-M0047-C001-L7
500
CCXFCB-L0087-C001-L6
500
1000
CCXFCB-M0087-C001-L6
CCXFCB-L0047-C001-L7
FutureCom™ F
S1200 Modules and Connectors
Introduction
Features
Category 7+ Module
Up to 1200 MHz bandwith per pair
Dust protection flap to prevent exposure to contaminants
FutureCom F
Wide range of installation options
Few individual components
High-level component density
S1200 Adapter
Removing the module icon (black plastic clasp on the upper
side of the S1200 Module) enables the S1200 module to be
inserted into the module adapter. The S1200 adapter ex-
tends the application possibilities of the Cat. 7 module to
many components in the LANscape® product range, such as:
Patch panels
Frame sets
Hardware
Floor box solutions
FutureCom UD FutureCom UE
FutureCom D
Individual components of the S1200 Module
FutureCom E
FutureCom 10TEN
Individual shielding of the modules
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
S1200 Module with adapter for LANscape® interface
S1200 Connector Types
For the FutureCom™ F System, the following connector types
are offered:
S1200/4 shielded connector, 4-pair
Industrial
Cable
(for solid or stranded conductors)
S1200/2 shielded connector, 2-pair
S1200/1 shielded connector, 1-pair
S1200 Connector Types
Corning Cable Systems
21
Further
Information
Special
Cable
All patch cords modes can be created using these connectors.
FutureCom™ F
Modules and Module Accessories
Features
Bandwidths up to 1200 MHz per pair of wires
Quick and easy to install
IDC connection (IDC = Insulation Displacement Contacts)
Universal usage (direct or with adapter) in many
LANscape® components
Negligible effect from interference through the individual shielding of the modules
Ordering Information
Order Number
CAXFSM-00100-C001
Description
S1200 module, 1 x S1200, shielded, Cat. 7+,
for installation in LANscape patch panels,
outlets and floor box mounting plates
S1200 Module Adapter
Order Number
CAXFSN-00110-C001
Blank Covers
Order Number
CAXFSN-00101-C001
CAXFSN-00108-C001
22
Description
S1200 module adapter, for the installation
of the S1200 modules in LANscape patch panels,
outlets and floor box mounting plates
Description
1 slot for installation in
FutureCom™ F S1200 patch panels,
outlets and floor box mounting plates
(S1200 direct assembly without module adapters)
white, RAL 9010
black, RAL 9005
Corning Cable Systems
Units per
Delivery
1/1
Units per
Delivery
6/1
Units per
Delivery
10/1
10/1
FutureCom™ F
S1200 Connectors
Introduction
Features
Bandwidths up to 1200 MHz per pair
Quick and easy to install
IDC connection (IDC = Insulation Displacement Contacts)
FutureCom F
High density, i.e. for each module the following connector
combinations can be used:
– one 4-pair connector
FutureCom 10TEN
– two 2-pair connectors
– one 2-pair connector and two 1-pair connectors
– four 1-pair connectors
Shielded connectors are designed for the use with S/FTP
FutureCom E
type cables
S1200/4 Connector, shielded, Cat. 7+,
Units per
Delivery
CAXFSS-00100-C004
1200/4 Connector, shielded, Cat. 7+,
1/1
4-pair, for solid wire AWG 22 to 23,
Further
Information
Special
Cable
Industrial
Cable
e.g. for consolidation point cabling
1/1
Hardware
4-pair, for flex wire cables AWG 26
FutureCom UD FutureCom UE
CAXFSS-00100-C001
Description
Order Number
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
S1200/4 Connector 4-pairs, shielded, Cat.7+
FutureCom D
Ordering Information
Corning Cable Systems
23
FutureCom™ F
S1200 Connectors
Ordering Information
S1200/2 Connector, 2-pair, shielded, Cat. 7+
Order Number
CAXFSS-00100-C002
Description
S1200/2 Connector, shielded, Cat.7+,
2-pair, for flex wire cable AWG 26
S1200/1 Connector, 1-pair, shielded, Cat. 7+
CAXFSS-00100-C003
24
S1200/1 Connector, shielded, Cat.7+,
1-pair, for flex wire cable AWG 26
Corning Cable Systems
Units per
Delivery
1/1
1/1
FutureCom™ F Tools
Introduction
Features of the S1200 Assembly Tool
Integrated knife for the removal of the jacket
Stripping option for the PiMF foils with a defined length
Management for arrangement or shaping of the individual
FutureCom F
pairs (PiMF)
CAXFSN-00000-C001
Description
S1200 Tool,
for the assembly
of S1200 modules
Units per
Delivery
FutureCom E
Order Number
1/1
FutureCom D
Ordering Information
FutureCom 10TEN
Defined section length of the wires
and S1200/4 or
1/1
CAXCSN-00000-C004
Copper Conducting Tape, 12.7 mm wide,
2/1
Further
Information
roll length 16.5 m
Special
Cable
the IDC contacts on FutureCom™ S1200 modules
Hardware
Comfort Parallel Pliers, for the termination of
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
CAXCSN-00000-C008
Industrial
Cable
Parralel Pliers and Copper Conducting Tape
FutureCom UD FutureCom UE
S1200/2 connectors
Corning Cable Systems
25
FutureCom™ F
Outlets and Outlet Accessories
Features of the Frame Set
Direct installation of S1200 modules
Central plate dimensions of 50 x 50 mm and can be combined with “DELTAprofil” and “DELTAfläche” face plates,
as well as face plates from other manufacturers
Designation window
Ordering Information
Order Number
CAXFSE-S0201-C001
Description
S1200 Frame Set, inclined,
for 2 FutureCom™ S1200 modules,
including mounting frame
and 50x50 mm central plate with
designation window,
threaded, white RAL 9010
Units per
Delivery
1/1
Features of the Frame Sets
Installation of S1200 modules with module adapters
Central plate dimensions of 50 x 50 mm and can be combined with “DELTAprofil” and “DELTAfläche” face plates,
as well as face plates from other manufacturers
Designation window
Order Number
WAXWSE-V0201-C001
WAXWSE-V0202-C001
Description
Frame Set, inclined, projecting,
for 2 S1200 modules with module
adapters, including mounting frame
and 50x 50 mm central plate with
designation window
and dust protection flaps
white, RAL 9010
pearl white, RAL 1013
Labeling icons and designations labels can be found on page 131.
Brackets for raceway mounting can be found on page 134.
26
Corning Cable Systems
Units per
Delivery
1/1
1/1
FutureCom™ F
Outlets and Outlet Accessories
Introduction
Features of the Universal Integration Housing
Direct assembly of S1200 modules
WAXWSE-V0201-C002
Description
Universal Housing, inclined, projecting,
for face plate (147x87 mm and 87x87 mm)
for the direct integration of 2 S1200 modules,
FutureCom 10TEN
Order Number
Units per
Delivery
1/1
FutureCom E
Ordering Information
FutureCom F
Surface mount housing suitable for the face plates; see page 136.
Face Plate, 87x87 mm,
for one housing,
including two metric screws and
FutureCom UD FutureCom UE
WAXWSE-00001-C005
FutureCom D
central partition provided, white, RAL 9010
1/1
two withworth screws,
for frame assembly in installation outlets,
white, RAL 9010
Hardware
(Suitable Surface Mount Housing
Face Plate, 87x147 mm,
1/1
for two housings,
including two metric screws
and two withworth screws,
for frame assembly in installation outlets,
white, RAL 9010
(Suitable Surface Mount Housing
Special
Cable
Industrial
Cable
WAXWSE-00001-C006; see page 136)
Further
Information
WAXWSE-00001-C007
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
WAXWSE-00001-C004; see page 136)
Corning Cable Systems
27
FutureCom™ F
Outlets and Outlet Accessories
Ordering Information
Order Number
Units per
Delivery
Description
Frame Set, inclined, for 3 S1200 modules
with module adapters,
including mounting frame and triple housing
with designation window
WAXWSE-V0301-C001
WAXWSE-V0302-C001
and dust protection flaps,
also as 80x80 mm face plate
white, RAL 9010
1/1
pearl white, RAL 1013
1/1
Frame Set, inclined, for 6 S1200 modules
with module adapters,
including mounting frame
and two triple housings
with designation window and
WAXWSE-V0601-C001
WAXWSE-V0602-C001
Installation Option
dust protection flaps,
also as a 151x80 mm face plate
white, RAL 9010
1/1
pearl white, RAL 1013
1/1
Frame Set, inclined, for 6 S1200 modules with module
adapters, including mounting frame and two triple housings
with designation window and dust protection flaps, as well
as 151 x 80 mm face plate, white, RAL 9010:
WAXWSE-V0601-C001
equipped with four S1200 modules with module adapters
CAXFSM-00100-C001 + CAXFSN-00110-C001
one triple MT-RJ OM3 module
LAXLSM-00212-C002
two black labeling icons
WAXWSE-00008-C001
two blue labeling icons
Frame Set, inclined, projecting, for 6 modules,
integrated into a raceway
WAXWSE-00004-C001
two green labeling icons
WAXWSE-00006-C001
one black SF/UTP flex/26 Cat. 5 Patch Cord
CCAFGD-D6024-A020-C1
and one blue S/FTP flex/26 Cat. 6 Patch Cord
CCAFGB-G2021-A030-C0
28
Corning Cable Systems
FutureCom™ F
Floor Box Solutions
Introduction
Features
Specially designed for the direct integration of S1200
modules
Stable metal construction, no additional installation
FutureCom F
trough required
Integrated cable strain relief that can be mounted
in various positions
FutureCom 10TEN
No screwing required
Integrated grounding bolt
Order Number
CAXFSU-00600-C001
Description
Mounting Panel for Ackermann Floor Boxes
GES 2, GES 4, GES 4/10, GESR 4, GES 6,
GES 6/10, GESR 7/10 (outer) or GES 8/10,
Units per
Delivery
FutureCom D
Ordering Information
FutureCom E
Designation window with title strips
1/1
FutureCom UD FutureCom UE
for the installation
of 6 FutureCom™ F S1200 modules,
with integrated cable strain relief
and six cable ties,
designation window, black
Mounting Panel for Ackermann Floor Boxes
GESR 7/10 (center), GES 9 or GESR 9, for
the installation
1/1
Hardware
CAXFSU-00900-C001
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
of 9 FutureCom F S1200 modules,
with integrated cable strain relief
and nine cable ties,
designation window, black
1/1
VanGeel Floor Box IK-1 (long),
for the installation
Industrial
Cable
Mounting Panel for
of 9 FutureCom F S1200 modules,
Special
Cable
with integrated cable strain relief
and nine cable ties,
designation window, black
Further
Information
CAXFSU-00900-C005
Corning Cable Systems
29
FutureCom™ F
Floor Box Solutions
Ordering Information
Order Number
CAXFSU-00900-C002
Description
Mounting Panel for Kleinhuis Floor Box
GR. II and GR. III (outside only),
for the installation
of 9 FutureCom™ F S1200 modules,
with integrated cable strain relief
and nine cable ties,
designation window, black
Installation Option
Mounting Panel for Kleinhuis Floor Boxes GR. II and GR. III
(only left or right position):
CAXFSU-00900-C002
The three 3-port mounting places are configured as follows:
equipped with two S1200 modules,
CAXFSM-00100-C001
one blank cover, white,
CAXFSN-00101-C001
and two gray 2-pair
SF/UTP flex/26 10/100BaseT Patch Cords
CCAFGD-D1024-A030-C1
equipped with two S1200 modules,
CAXFSM-00100-C001
one blank cover, black,
CAXFSN-00108-C001
equipped with three S1200 modules,
CAXFSM-00100-C001
and one blue S/FTP flex/26 Cat. 6 Patch Cords
CCAFGB-G2021-A030-C0
For applications requiring fiber optic and copper solutions,
the S1200 module can be integrated into the various floor
box mounting panels from the LANscape® product range
using an adapter (see pages 144-151).
30
Corning Cable Systems
Units per
Delivery
1/1
FutureCom™ F
S1200 Patch Panels
Introduction
Features
Specially designed for the direct integration of S1200
modules
Integrated shielded transitional spring
Order Number
CAXFSV-02400-C001
Description
S1200 Patch Panel 19“, shielded, Cat. 7+,
including 24 FutureCom™ F S1200 modules,
with integrated cable strain relief and shielded
Units per
Delivery
FutureCom E
Ordering Information
FutureCom 10TEN
FutureCom F
Patch panel accessories, see page 156
1/1
S1200 Patch Panel 19“,
for max. 24 FutureCom F S1200 modules,
with integrated cable strain relief and shielded
FutureCom UD FutureCom UE
CAXFSV-02400-C002
FutureCom D
transitional spring, 1 U, high-grade steel
1/1
transitional spring, 1 U,
for max. 12 FutureCom F S1200 modules,
with integrated cable strain relief and shielded
1/1
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
S1200 Patch Panel 10“,
transitional spring, 1 U,
Special
Cable
Industrial
Cable
high-grade steel front panel
Further
Information
CAXFSV-01200-C001
Hardware
high-grade steel
Corning Cable Systems
31
Consolidation Point Housings
for S1200 Modules
Features
Full metal housing for the installation of up to
12 FutureCom™ S1200 modules
Standard-compatible according to ISO/IEC 11801 (2002)
and EN 50173-1 (2003)
Easy installation for a distribution or consolidation point
Consolidation point housing is suitable for ceiling, wall,
false floor or desk assembly
Individual strain relief for the incoming and outgoing
cable sections
Dust-proof feedthrough for incoming cable
Easy plug-in of consolidation point cable (dust protection
and mechanical protection)
Housing base electrically conductive for optimal
shielding transition or grounding
Installation height of 60 mm
Housing is fastened using special non-detachable screws
Black sheet steel housing top, RAL 9005
Ordering Information
Order Number
Description
WAXWSW-00008-C014 Consolidation Point Housing for max. 12 FutureCom F S1200 modules,
with strain relief for incoming data cables, patch cord strain relief and
dust protection flap for floor, wall and ceiling installation,
60 x 263 x 320 mm (HxWxD)
32
Corning Cable Systems
Units per
Delivery
1/1
FutureCom™ F
Cat. 7 Patch Cords S1200 to S1200
Introduction
Description
FutureCom F Category 7 patch cords are available in two or
four pair versions with foil and full braided shielding (S/FTP).
They are pre-terminated with shielded S1200 connectors on
FutureCom F
both ends and are available in various lengths. The patch
cords meet all the transmision property requirements for
FutureCom 10TEN
Channel F (2002).
Features
FutureCom E
S/FTP flex cable, specified up to 600 MHz
S1200/4 connector pair fully configured and
application-neutral
FutureCom D
S1200/4 connector pair for up to 10GBase-T applications
S1200/2 connector pair fully configured on both sides
Minimum surface transfer impedance
(<10 mV/m at 10 MHz)
010
015
020
030
040
050
060
100
=
=
=
=
=
=
=
=
1 meter
1.5 meters
2 meters
3 meters
4 meters
5 meters
6 meters
10 meters
1
1
- C1
Select length.
010
015
020
030
040
050
060
100
=
=
=
=
=
=
=
=
1 meter
1.5 meters
2 meters
3 meters
4 meters
5 meters
6 meters
10 meters
Hardware
CCAFGB - G1026 - A
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Select length.
- C0
Industrial
Cable
1
1
Special
Cable
CCAFGB - G1022 - A
Further
Information
Ordering Information
FutureCom UD FutureCom UE
Outstanding transmission characteristics
Corning Cable Systems
33
FutureCom™ F
Cat. 6 Patch Cords S1200/4 to RJ45
Description
Application-neutral, Category 6 S/FTP patch cords with four
pairs are pre-terminated with S1200/4 and RJ45 connectors.
The patch cords meet all the transmision property
requirements for Channel E (2002) and Cat. 6 (2002).
Features
S/FTP flex cable, specified up to 600 MHz
Pre-terminated with S1200/4 on one end and RJ45 on the
other end
Minimum surface transfer impedance
(<10 mV/m at 10 MHz)
Outstanding transmission characteristics
4-pair, AWG 26, Cat. 6 (2002)
Ordering Information
CCAFGB - G
1
Select color.
2
Select length.
1
2
3
4
5
6
=
=
=
=
=
=
gray
blue
yellow
green
red
black
010
015
020
030
040
050
060
080
100
150
=
=
=
=
=
=
=
=
=
=
1 meter
1.5 meters
2 meters
3 meters
4 meters
5 meters
6 meters
8 meters
10 meters
15 meters
34
1
021 - A
2
- C0
Corning Cable Systems
FutureCom™ F
Cat. 5 Patch Cords S1200/4 to RJ45
Introduction
Description
Application-neutral, Category 5 SF/UTP patch cords with four
pairs are pre-terminated with S1200/4 and RJ45 connectors.
The patch cords meet all the transmision property require-
FutureCom F
ments for Channel D (2002) and Cat. 5 (2002).
FutureCom 10TEN
Features
SF/UTP flex cable, specified up to 300 MHz
FutureCom E
Pre-terminated with S1200/4 and RJ45 connectors
Minimum surface transfer impedance
(<10 mV/m at 10 MHz)
FutureCom D
Outstanding transmission characteristics
Select length.
=
=
=
=
=
=
gray
blue
yellow
green
red
black
010
015
020
030
040
050
060
080
100
=
=
=
=
=
=
=
=
=
1 meter
1.5 meters
2 meters
3 meters
4 meters
5 meters
6 meters
8 meters
10 meters
Hardware
2
1
2
3
4
5
6
- C0
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Select color.
2
Industrial
Cable
1
1
021 - A
Special
Cable
CCAFGF - D
Further
Information
Ordering Information
FutureCom UD FutureCom UE
4 Pair, AWG 26, Cat. 5 (2002)
Corning Cable Systems
35
FutureCom™ F
Cat. 5 Patch Cords S1200/2 to RJ45
Description
Category 5 SF/UTP patch cords with two pairs are
pre-terminated with S1200/2 and RJ45 connectors. The patch
cords meet all the transmision property requirements for
Channel D (2002) and Cat. 5 (2002).
Features
SF/UTP flex cable, specified up to 300 MHz
Pre-terminated with S1200/2 and RJ45 connectors
Minimum surface transfer impedance
(<10 mV/m at 10 MHz)
Outstanding transmission characteristics
2 Pair, AWG 26, Cat. 5 (2002)
Ordering Information
For 10/100 Base-T Applications (Pins 1.2 - 3.6)
CCAFGD - D
1
Select color.
2
Select length.
10
60
010
015
020
030
040
050
060
080
100
150
36
=
=
=
=
=
=
=
=
=
=
=
=
1
24 - A
gray
black
1 meter
1.5 meters
2 meters
3 meters
4 meters
5 meters
6 meters
8 meters (gray only)
10 meters (gray only)
15 meters (gray only)
2
- C1
For TR/ISDN and Analog Applications
(Pins 4.5 - 3.6)
CCAFGD - D
1
2
Select color.
1
24 - A
11 = gray
41 = green
Select length.
010
015
020
030
040
050
060
080
100
150
Corning Cable Systems
=
=
=
=
=
=
=
=
=
=
1 meter
1.5 meters
2 meters
3 meters
4 meters
5 meters
6 meters
8 meters (gray only)
10 meters (gray only)
15 meters (gray only)
2
- C1
FutureCom™ F
U/UTP Flex Patch Cords
Introduction
Description
FutureCom™ F U/UTP flex FRNC patch cords are pre-
terminated with S1200/1 or S1200/2 and RJ45 or RJ11/12
FutureCom F
connectors for service specific applications.
FutureCom 10TEN
Features
U/UTP flex cable, specified up to 100 MHz
Pre-terminated with S1200/1 or S1200/2 connectors
FutureCom E
Pre-terminated with RJ11/12 or RJ45 connectors
Minimum surface transfer impedance
(<10 mV/m at 10 MHz)
1
Select application.
2
Select connector types.
1
0
=
=
2 Pair, TR/ISDN and analog (4.5 - 3.6)
1 Pair, Telephone / Neutral
24
25
27
28
34
=
=
=
=
=
S1200/2 to RJ45
S1200/2 to RJ11
S1200/1 to RJ45 (Telephone)
S1200/1 to RJ11 (Telephone)
S1200/1 to S1200/1 (Neutral)
010
015
020
030
040
050
060
080
100
=
=
=
=
=
=
=
=
=
1 meter
1.5 meters
2 meters
3 meters
4 meters
5 meters
6 meters
8 meters
10 meters
3
- C0
Special
Cable
Select length.
Further
Information
3
2
-A
Hardware
1
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
CCAFFE - A6
Industrial
Cable
Ordering Information
FutureCom UD FutureCom UE
FutureCom D
FRNC cable, unshielded
Corning Cable Systems
37
FutureCom™ F
TV Connecting Cable
Features
S1200/1 connector and balun (connector or jack) for the
conversion of Cat.7+ cabling into coaxial cabling
incl. impedance adjustment
Very low surface transfer impedance (<10 mV/m at 10 MHz)
Specifications
Insertion Attenuation
Back-to-back
Return loss
(75 V
(100 V
Measured at the 75 V end
100 V)
< 2 dB
75 V)
< 3.5 dB
The 100 V end is terminated with a resistor of 100 V.
Surface transfer impedance
Rk [mV]
Ordering Information
Order Number
Description
< 19 dB
< 12 dB
< 20 mV
Length
CCAFGB-I4054-A030-C0
FutureCom™ TV/CATV Patch Cord,
3m*
CCAFGB-I4055-A030-C0
FutureCom TV/CATV Patch Cord,
3m*
* Other lengths upon request
38
1 x S1200/1 and 1xTV connector (IEC60169-2),
FRNC sheath, green
1 x S1200/1 connector and 1 xTV jack
(IEC60169-2), FRNC sheath, green
Corning Cable Systems
Frequency Range
5...300 MHz
300...450 MHz
5...300 MHz
300...450 MHz
10 MHz
FutureCom™ F
Plug & Play™ Solution
Introduction
Application
The S1200 Solution Packages are factory pre-terminated cables. They are offered with
FutureCom™ S/FTP 1200/22 cables, and enable Plug & Play™ installation, significantly
reducing installation time. The assemblies are 100% factory tested, preventing installation faults on-site.
CCAFCB-M2042-A250-C0
CCAFCB-M2042-A300-C0
CCAFCB-M2042-A350-C0
CCAFCB-M2042-A400-C0
CCAFCB-M2042-A450-C0
CCAFCB-M2042-A500-C0
CCAFCB-M2042-A550-C0
CCAFCB-M2042-A600-C0
CCAFCB-M2042-A650-C0
CCAFCB-M2042-A700-C0
CCAFCB-M2042-A750-C0
CCAFCB-M2042-A800-C0
CCAFCB-M2042-A850-C0
CCAFCB-M2042-A900-C0
CCAFCB-M2042-A950-C0
S1200 Solution Package S/STP1200/22 - 10
10 m
S1200 Solution Package S/STP1200/22 - 25
25 m
S1200 Solution Package S/STP1200/22 - 15
S1200 Solution Package S/STP1200/22 - 20
S1200 Solution Package S/STP1200/22 - 45
45 m
S1200 Solution Package S/STP1200/22 - 40
S1200 Solution Package S/STP1200/22 - 50
S1200 Solution Package S/STP1200/22 - 55
S1200 Solution Package S/STP1200/22 - 60
S1200 Solution Package S/STP1200/22 - 65
35 m
40 m
50 m
55 m
60 m
65 m
S1200 Solution Package S/STP1200/22 - 70
70 m
S1200 Solution Package S/STP1200/22 - 85
85 m
S1200 Solution Package S/STP1200/22 - 75
S1200 Solution Package S/STP1200/22 - 80
S1200 Solution Package S/STP1200/22 - 90
S1200 Solution Package S/STP1200/22 - 95
Description
CP Solution Package S/FTP1200/22, 4 pairs,
application-neutral, FRNC jacket,
FutureCom 10TEN
20 m
30 m
S1200 Consolidation Point Solution Packages
Order Number
15 m
S1200 Solution Package S/STP1200/22 - 30
S1200 Solution Package S/STP1200/22 - 35
FutureCom E
with 2 S1200 Modules
FutureCom D
CCAFCB-M2042-A200-C0
FRNC jacket, pre-terminated
FutureCom UD FutureCom UE
CCAFCB-M2042-A150-C0
data cable, 4 pairs, application neutral,
Length
Hardware
CCAFCB-M2042-A100-C0
Description
Solution Package with S/FTP 1200/22
75 m
80 m
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Order Number
90 m
95 m
Length
Industrial
Cable
S1200 Solution Packages
FutureCom F
Ordering Information
CCAFCB-M2058-A100-C0
CCAFCB-M2058-A150-C0
CCAFCB-M2058-A200-C0
for consolidation points
CP Solution Package S/STP1200/22 -5
CP Solution Package S/STP1200/22 -10
CP Solution Package S/STP1200/22 -15
CP Solution Package S/STP1200/22 -20
5m
10 m
15 m
Further
Information
CCAFCB-M2058-A050-C0
connector and one S250 module
Special
Cable
pre-terminated with one S1200/4
20 m
Corning Cable Systems
39
FutureCom™ F
Test Adapter Cables
Applications
For acceptance tests, special Test Adapter Cables are needed
for the Fluke DSP 4x00 and Microtest OMNIScanner/-
OMNIScanner 2 testers in accordance with Class F (2002).
A pair of these test adapter cables is always required to perform the test.
Ordering Information
CCAFGB-G20ME-A020-C0
Description
S1200 Test Adapter Cable, 2 m,
Units per
Delivery
CCAFGB-G20MM-A020-C0
S1200 Test Adapter Cable, 2 m, for Microtest
2/1
Order Number
for Fluke DSP 4x00 (per pair)
OMNIScanner/OMNIScanner 2 (per pair)
If you require test adapter cables for other testing equipment (e.g. LANTEK 7), please contact the relevant
manufacturer directly.
40
Corning Cable Systems
2/1
3.3. Cable
46
3.4. Connecting Hardware
3.4.1. S10TEN Module Overview
47
3.4.2. S10TEN Module
48
3.5.1. S10TEN Outlets
49
3.5. Hardware
3.5.2. S10TEN Patch Panels
49
3.6.1. 10GBase-T Patch Cords
50
3.6. Patch Cords
3.6.2. Consolidation Point Patch Cords
51
3.7. Plug & Play™
52
54
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
3.8. Test Cable
FutureCom F
45
FutureCom 10TEN
3.2. Certificate
FutureCom E
42
FutureCom D
3.1. System Descriptions & Data
FutureCom UD FutureCom UE
FutureCom™ 10TEN System
Further
Information
3
Introduction
Table of contents
Corning Cable Systems
41
FutureCom™ 10 System
TEN
Corning Cable Systems’ FutureCom™ 10 System has been especially developed to support 10 Gigabit Ethernet (10GBase-T)
TEN
over 100 meters. FutureCom 10 is the latest addition to Pretium™ Solutions, Corning Cable Systems’ high-performance
TEN
fiber and copper solutions for premises networks, and is fully compliant with the IEEE 802.3an (Draft 2.0) standard for
10 Gigabit Ethernet transmission. The current FutureCom 10 is especially designed for 10 Gigabit applications in riser and
TEN
horizontal environments, avoiding alien near-end and far-end cross talk (ANEXT, AFEXT), in order to warrant the higher
performance of cabling through immunity.
Face Plate
“DELTAprofil”,
80x80 mm
WAXWSE-00001-C001
and S10TEN outlet,
2xRJ45,
10GBase-T, inclined
CAXTSD-S0201-C001
S/FTP flex/26, gray,
2xRJ45 connectors,
4 pairs, for up to
10 GBase-T
CCATGD-G1002-A020-C0
FutureCom
S/FTP900/23
CCXEDB-I0047-C001-L7
S10TEN Patch Panel 19“,
for max. 24 S10TEN
modules,
with integrated cable
strain relief, 1 U,
front panel of
high-grade steel
WAXTSV-02400-C001
S10 Module,
1 x RJ45,shielded,
10GBase-T
CAXTSM-00112-C001
TEN
S/FTP flex/26, gray,
2xRJ45- connectors,
4 pairs, for up to
10GBase-T
CCATGB-G1002-A020-C0
A very high level of system performance is achieved for the
It is suitable for all recognized standardized voice and data
maximum future security and reliability.
The performance of the FutureCom 10TEN cabling system has
link through the use of high-quality 10GBase-T connection
technology. The quality of the components guarantees
Using all eight contacts in the RJ45 Connector as well as in
the RJ45 Module, the cabling can be used universally and is
application-independent.
42
transmission applications up to 10GBase-T.
been certified by an independent testing body (see certificate). Of course, all standardized EMC threshold values in
Europe are observed.
Corning Cable Systems
FutureCom™ 10 System Data
for Channel 10GBase-T
61.0
Min. ACR in dB according to standard *
88.1
ACR in dB (typ. FutureCom 10 values)
TEN
63.3
Min. ELFEXT in dB* according to standard *
80.4
ELFEXT in dB (typ. FutureCom 10 values)
TEN
19.0
Min. return loss in dB according to standard *
33.9
Return loss in dB (typ. FutureCom 10TEN values)
* According to IEEE 802.3 an (draft 2.0).
85.3
78.5
–
61.9
–
32.7
–
8.0
75.0
–
66.6
–
56.4
–
30.7
–
63.6
57.9
14.3
–
49.5
–
52.9
–
32.4
–
18.1
39.9
18.2
40.1
23.3
51.8
12.0
32.1
155.5 200
–
–
250 500
35.9 53.4
53.3
47.9 37.6
22.7
–
31.3
–
44.3
–
31.3
–
25.7
50.7
–
25.8
–
41.0
–
30.3
–
28.8 41.9
33.1
22.0
– 2.8 – 31.4
20.2 -2.0
15.3
38.1
7.2
9.3
31.3
6.0
26.5 22.1
The system values cited only apply to the use of original FutureCom 10TEN products. Derived values, such as PSACR, PSNEXT,
PSELFEXT, are in observance of the standard values, but are not shown.
Attenuation and
Near-end Crosstalk (NEXT)
NEXT in dB
(typ. FutureCom 10TEN values)
min. NEXT in dB
According to Standard
max. Attenuation in dB
According to Standard
Attenuation in dB
(typ. FutureCom 10TEN values)
Further
Information
Special
Cable
Industrial
Cable
Frequency in MHz
FutureCom F
TEN
–
100
21.7
FutureCom 10TEN
Min. NEXT in dB according to standard *
5.6
62.5
–
FutureCom E
89.4
65.0
20
–
FutureCom D
NEXT in dB (typ. FutureCom 10 values)
2.0
Attenuation in dB (typ. FutureCom 10TEN values)
10
–
FutureCom UD FutureCom UE
Max. attenuation in dB according to standard *
1
4.0
Hardware
Frequency in MHz
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Electrical Characteristics (at 20°C)
Introduction
TEN
Corning Cable Systems
43
FutureCom™ 10 System Data
for Channel 10GBase-T
TEN
Far-end Crosstalk Relating
to the Far End (ELFEXT)
ELFEXT in dB
(typ. FutureCom 10TEN values)
Min. ELFEXT in dB
According to standard
Frequency in MHz
Return Loss
Return loss in dB
(typ. FutureCom 10TEN values)
min. Return loss in dB
According to standard
Frequency in MHz
Test Setup
FutureCom 10TEN Test Cord, 2 m
S10
TEN
Module
FutureCom F/STP 900/23
S10TEN Patch Panel 19“
FutureCom 10TEN Test Cord, 2 m
44
Nominal intrinsic impedance
Max. DC loop resistance (according to standard)
DC loop resistance
(typ. FutureCom 10TEN values)
Max. delay (according to standard)
Max. delay (typ. FutureCom 10TEN values)
Corning Cable Systems
100 V
40 V
18 V
0.05 µs
, 0.02 µs
Further
Information
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
FutureCom 10TEN
FutureCom F
Introduction
FutureCom™ 10 Certificate
TEN
Corning Cable Systems
45
FutureCom™ 10 10GBase-T Cables
TEN
Braided shield
Halogen-free jacket,
flame retardant
Twisted pair
Foil shielding (PiMF)
4 shielded pairs
PE foam-skin insulation
Features
Copper conductor
AWG 23 - AWG 22
Application
The cables for the FutureCom™ S10TEN System are designed
for applications up to 1500 MHz (S/FTP 600 up to S/FTP 1500*).
Their transmission characteristics significantly exceed the
requirements defined by today’s Category 7 specifications
(EN50288-4-1).
FutureCom cables are low-skew products, i.e. the skew
between the individual pairs is very low. This is increasingly
required for applications running 10 Gigabit Ethernet. The
possibility of using the cable up to the GHz area enables the
highest possible transmission rates for multimedia applications, such as TV transmission, in future-proof networks.
Each pair is individually foil shielded (FTP). The stranded
pairs (PiMF) are also sheathed with a braid shield (S/FTP),
Specified up to 1500 MHz
which guarantees outstanding shielding characteristics. The
Outstanding electrical characteristics
cable satisfies Class B interference radiation standards
Each pair is shielded (PiMF)
(EN 55022), as well as immunity (EN 55024), which enables
Full copper braid shield
the realization of CE-compatible networks.
Streamlined design
Lightweight
Low signal skew between the pairs
Halogen-free (LSZH)
Fire retardant according to IEC 60332-3, Category C
Non-corrosive according to IEC 60754-2 (FRNC)
Low smoke according to IEC 61034
* For S/FTP 600 and 900 cable please see pages 61-63. For
S/FTP 1500 and 1200 cable please see pages 18-20.
46
Corning Cable Systems
FutureCom™ S10
Module Overview
TEN
Introduction
Features
Fully compatible with all modular LANscape® systemes
Wide range of installation options
Few individual components
FutureCom F
High-level component density
Individual shielding
Halogen-free
Individual Components of the S10TEN Module
FutureCom D
FutureCom™ S10TEN Technology
FutureCom E
FutureCom 10TEN
Fire class UL94V-0
Optimized construction with printed circuit board for
Proven IDC technology for wires with AWG 24 to AWG 22
Module reusable several times
Disassembled S10TEN Module
Application
Wire management using TIA/EIA 568 A/B coding
Transparent wire management allows direct control of
correct wiring
Installation in pairs (no untwisting of pairs is necessary)
Industrial
Cable
Rapid assembly times
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
More than 1500 connector cycles are possible
Hardware
FutureCom UD FutureCom UE
bandwidths of more than 500 MHz
Easy handling
S10TEN Wire Management, without/with cable
Corning Cable Systems
47
Further
Information
Special
Cable
Compatible with all FutureCom S/FTP cables
FutureCom™ 10
S10 Module
TEN
TEN
Features
Easy and quick to install, no special tools required
IDC connection (IDC = Insulation Displacement Contacts)
High-level component density
Universal usage in all modular LANscape®
and FutureCom™ components
10GBase-T
Ordering Information
Order Number
CAXTSM-00112-C001
Description
S10TEN Module, 1xRJ45, shielded,
10GBase-T, module aqua,
with transparent TIA/EIA 568 A/B
Unit per
Delivery
1/1
wire management, incl. copper
conducting tape for installation
in LANscape modular patch panels,
outlets and floor box solutions
Cable Strain Relief
Using the additional cable strain relief allows increased pulling forces on the module housings.
Order Number
CAXCSN-00000-C001
Description
Additional cable strain relief,
for fixing higher pulling forces
on shielded FutureCom modules
for solid wire, and for assembly of
flexible consolidation point cables
with FutureCom S10TEN fx, S250fx and
U250fx modules
48
Corning Cable Systems
Unit per
Delivery
100/1
FutureCom™ 10
S10 Outlets and Patch Panels
TEN
TEN
Order Number
CAXTSD-S0201-C001
Unit per
Delivery
Description
S10TEN Outlet, 2xRJ45,
shielded,10GBase-T,
inclined, incl. mounting frame
FutureCom F
S10TEN Outlets
Introduction
Ordering Information
1/1
FutureCom 10TEN
with grounding flaps,
central plate 50x50 mm
with designation window, screw fixing,
copper conducting tape
S10TEN Outlet,
2xRJ45, shielded,10GBase-T,
inclined, incl. mounting frame with
1/1
FutureCom D
CAXTSD-S0202-C001
white, RAL 9010
FutureCom E
(without faceplate),
grounding flaps, central plate 50x50 mm
FutureCom UD FutureCom UE
with designation window, screw fixing,
copper conducting tape
(without faceplate)
Order Number
CAXTSV-02400-C001
Description
S10TEN Patch Panel 19“, shielded,
10GBase-T, incl. 24 FutureCom S10TEN
modules and copper conducting tape,
Unit per
Delivery
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
S10TEN Patch Panel
Hardware
pearl white, RAL 1013
1/1
with integrated strain relief, 1 U,
for up to 24 FutureCom S10
TEN
modules, with integrated strain
1/1
Special
Cable
S10TEN Patch Panel 19“,
relief, 1 U, high-grade steel front panel
Corning Cable Systems
Further
Information
WAXTSV-02400-C001
Industrial
Cable
high-grade steel front panel
49
FutureCom™ 10
Patch Cords RJ45 to RJ45
TEN
Description
The FutureCom™ 10TEN System patch cords consist of Cate-
gory 7 flexible cables with shielded RJ45 connectors at both
ends. The flex cables have four individual foil-shielded pairs
and full braid copper shielding.
The zero halogen patch cords (LSZH) are non-corrosive
(according to IEC 60754-2), low smoke (according to IEC
61034) and flame retardant (according to IEC 60332-1).
FutureCom 10TEN patch cords provide additional latch
protection. They are available in various lengths and colors.
Features
Flex cable specified up to 600 MHz
Minimum surface transfer impedance
(<10 mV/m at 10 MHz)
Outstanding transmission characteristics for 10GBase-T
Additional latch protection
Ordering Information
CCATGB - G
1
Select color.
1
2
3
4
5
6
50
=
=
=
=
=
=
gray
blue
yellow
green
red
black
1
002 - A
2
2
- C0
Select length.
010
015
020
030
040
050
060
075
080
100
150
200
250
300
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1 meter
1.5 meters
2 meters
3 meters
4 meters
5 meters
6 meters
7.5 meters
8 meters
10 meters
15 meters
20 meters (gray only)
25 meters (gray only)
30 meters (gray only)
Corning Cable Systems
FutureCom™ 10
Consolidation Point Patch Cords
TEN
Introduction
Description
The FutureCom™ 10TEN Consolidation Point Patch Cords are
factory terminated cable assemblies with one S10TEN fx
module and one RJ45 connector. FutureCom S/FTP flex/26
FutureCom F
cable is specified up to 600 MHz and satisfies Category 7
transmission characteristics. The CP Patch Cords are suitable
for connection from LANscape® Consolidation Point Hous-
FutureCom E
FutureCom 10TEN
ings to wall or desktop outlets.
Description
S/FTP flex/26 Patch Cords, 4 pairs
application-neutral, FRNC sheath,
FutureCom UD FutureCom UE
Order Number
FutureCom D
Ordering Information
Length
gray, pre-terminated with one RJ45
Other lengths upon request
CP Patch Cords S/FTP flex/26 - 20
Hardware
CP Patch Cords S/FTP flex/26 - 15
5m
10 m
15 m
20 m
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
CCATGB-F1062-A200-C0
CP Patch Cords S/FTP flex/26 - 10
Industrial
Cable
CCATGB-F1062-A150-C0
CP Patch Cords S/FTP flex/26 - 5
Special
Cable
CCATGB-F1062-A100-C0
for 10GBase-T applications
Further
Information
CCATGB-F1062-A050-C0
connector and one S10TEN fx module,
Corning Cable Systems
51
FutureCom™ 10
Plug & Play™ Solutions
TEN
Application
The S10TEN Solution Packages are pre-terminated cables with
S10TEN modules at both ends. They are generally offered with
FutureCom™ S/FTP 900/23 cables. Both modules are
equipped with additional cable strain relief to allow higher
pulling force during installation (the pulling force is re-
stricted by the cable only). They enable Plug and Play™ installation and therefore significantly reduce installation
time. 100% factory testing reduces failures during installation.
Ordering Information
Order Number
Description
S10 Solution Package, with
TEN
S/FTP 900/23 cable,
Length
4 pairs, FRNC jacket, pre-terminated
CCATDB-F2063-A100-C0
CCATDB-F2063-A150-C0
CCATDB-F2063-A200-C0
CCATDB-F2063-A250-C0
CCATDB-F2063-A300-C0
CCATDB-F2063-A350-C0
CCATDB-F2063-A400-C0
CCATDB-F2063-A450-C0
CCATDB-F2063-A500-C0
CCATDB-F2063-A550-C0
CCATDB-F2063-A600-C0
CCATDB-F2063-A650-C0
CCATDB-F2063-A700-C0
CCATDB-F2063-A750-C0
CCATDB-F2063-A800-C0
CCATDB-F2063-A850-C0
CCATDB-F2063-A900-C0
52
with 2 S10TEN modules,
and additional cable strain relief
S10TEN Solution Package S/FTP 900/23 - 10
S10TEN Solution Package S/FTP 900/23 - 15
S10TEN Solution Package S/FTP 900/23 - 20
S10
TEN
Solution Package S/FTP 900/23 - 25
S10TEN Solution Package S/FTP 900/23 - 30
10 m
15 m
20 m
25 m
30 m
S10TEN Solution Package S/FTP 900/23 - 35
35 m
Solution Package S/FTP 900/23 - 50
50 m
S10TEN Solution Package S/FTP 900/23 - 65
65 m
S10TEN Solution Package S/FTP 900/23 - 80
80 m
S10TEN Solution Package S/FTP 900/23 - 40
S10TEN Solution Package S/FTP 900/23 - 45
S10
TEN
S10TEN Solution Package S/FTP 900/23 - 55
S10
TEN
Solution Package S/FTP 900/23 - 60
S10TEN Solution Package S/FTP 900/23 - 70
S10TEN Solution Package S/FTP 900/23 - 75
S10TEN Solution Package S/FTP 900/23 - 85
S10TEN Solution Package S/FTP 900/23 - 90
Corning Cable Systems
40 m
45 m
55 m
60 m
70 m
75 m
85 m
90 m
FutureCom™ 10
Plug & Play™ Solutions
TEN
Introduction
Application
The S10TEN Plug and Play™ Solution has been especially cre-
ated for use in data center applications. This special
assembly consists of six S/FTP 900/23 cables, with a com-
FutureCom F
mon FRNC jacket. The cable is pre-terminated with six S10TEN
modules at both ends. All modules are equipped with addi-
tional cable strain relief, to allow higher pulling force during
FutureCom 10TEN
installation (the pulling force is restricted by the cable only).
They enable rapid Plug and Play installation in data centers
and therefore significantly reduce installation time. 100%
6x S/FTP 900/23 cables with common
Length
FRNC jacket, both ends terminated
CCATDB-F2663-A200-C0
CCATDB-F2663-A300-C0
CCATDB-F2663-A400-C0
with 6 S10TEN modules,
and additional cable strain relief
S10TEN Plug & Play Solution Package, 6x S/FTP 900/23 - 20
S10TEN Plug & Play Solution Package, 6x S/FTP 900/23 - 30
S10TEN Plug & Play Solution Package, 6x S/FTP 900/23 - 40
*Other lengths available upon request.
Installation Option
20 m
30 m
40 m
S10TEN Plug & Play Solution Package, with 6x S/FTP 900/23
cables with common FRNC jacket, both ends terminated
with 6 S10TEN modules, and additional cable strain relief:
CCATDB-F2663-A200-C0
installed in a CCHE Empty Panel for 6 LANscape modules
Further
Information
Special
Cable
CCHE-CP00-LS
CCHE Panel with Plug & Play Solution Package
Corning Cable Systems
FutureCom UD FutureCom UE
S10 Plug & Play Solution Package, with
TEN
Hardware
Description
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Order Number
Industrial
Cable
Ordering Information
FutureCom D
FutureCom E
factory testing reduces failures during installation.
53
FutureCom™ 10
Universal Test Cord for Channel Testing
TEN
Application
The universal channel test cord can be used for acceptance
tests of shielded FutureCom 10TEN system in conjunction with
the universal test adapter from Fluke or other test device
manufactureres.
One pair of these test cords is required for acceptance tests.
Ordering Information
Order Number
CCATGB-F10M0-A030-C0
Description
Universal Test Cord for the acceptance tests
of the FutureCom 10
TEN
system in conjunction
with the universal test adapter from Fluke
or another test device manufacturers,
2xRJ45, 4 pairs, 3 m
54
Corning Cable Systems
Units per
Delivery
1/1
4.2.3. Cat. 6 F/FTP 450/23 Cable
66
4.3.1. S250 Module Overview
68
4.3. Connecting Hardware
4.3.2. Certificate for S250 Module
69
4.3.3. S250 Module
70
4.3.4. S250fx Module
71
4.4. Hardware
4.4.1. S250 Outlets and Patch Panel
72
4.4.3. Installation Options for Outlets
74
4.5.1. Cat.6 Patch Cords
75
4.4.2. S250 Double Module Outlet
73
4.5. Patch Cords
4.5.2. Consolidation Point Patch Cords
76
4.6. Plug & Play™
77
79
Special
Cable
Industrial
Cable
4.7. Test Cable
FutureCom F
64
FutureCom 10TEN
4.2.2. Cat. 6 S/FTP 450/23 Cable
61
FutureCom E
4.2.1. Cat. 7 S/FTP 900/23 and S/FTP 600/23 Cable
FutureCom D
4.2. Cable
FutureCom UD FutureCom UE
56
Hardware
4.1. System Descriptions & Data
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
FutureCom E
Further
Information
4
Introduction
Table of contents
Corning Cable Systems
55
FutureCom™ E System
FutureCom E is Corning’s proven system solution for symmetrical cabling. It exceeds all requirements of the current ISO/IEC
11801 (2002) and EN 50173-1 (2003) standards, Class D and E links and Categories 5 and 6 for components. In addition, the
FutureCom E system also satisfies Category 5e according to TIA/EIA-568-A-5.
Face Plate
“DELTAprofil”,
80x80 mm
WAXWSE-00001-C001
and S250 outlet,
2xRJ45,
Cat.6, inclined,
CAXESD-S0201-C001
S/FTP flex/26, blue,
2xRJ45 connectors,
4 pairs,
for 10/100/1000Base-T
CCAEGB-G2002-A020-C0
FutureCom
S/FTP 600/23
CCXEDB-F0047-C001-L7
19“ Patch Panel, for
max. 24 LANscape®
modules,
with integrated cable
strain relief, 1 U,
front panel of
high-grade steel
WAXWSV-02400-C001
S250 Module,
1 x RJ45,shielded, Cat. 6
CAXESM-00100-C001
S/FTP flex/26, blue,
2xRJ45- connectors,
4 pairs, for
10/100/1000 Base-T
CCAEGB-G2002-A020-C0
A very high level of system performance is achieved for the
The system is suitable for all recognized standardized voice
cords. The resulting performance and the future security
Ethernet (100Base-TX) and Gigabit Ethernet (1000Base-T)
link through the use of high-quality Category 6 connection
technology, Category 6 and 7 cables and Category 6 patch
guaranty maximum investment protection.
Fully configured with a RJ45 connector and RJ45 module, the
cabling can be used universally and is application-neutral.
56
and data transmission procedures. This applies to analog
voice transmission, ISDN,Token Ring, Ethernet (10/100Base-T),
and for future high bit-rate transmission procedures.
The performance of the FutureCom E cabling system has
been certified by an independent testing body (see certificate). Of course, all standardized EMC threshold values in
Europe are observed.
Corning Cable Systems
ACR in dB (typ. FutureCom E values)
Min. ELFEXT in dB*
ELFEXT in dB (typ. FutureCom E values)
Min. return loss in dB*
Return loss in dB (typ. FutureCom E values)
* According to ISO/IEC 11801 (2002)
61.0
70.6
63.3
73
19.0
22.0
63.0
–
58.5
–
65.0
–
22.0
–
8.0
58.3
–
50.3
–
60.0
–
22.0
–
100
21.7
50.0
46.6
12.5
–
37.5
–
48.0
–
20.0
–
16.5
39.9
18.2
30.0
23.3
46.0
12.0
18.0
155.5
–
20.0
43.7
–
23.7
–
38.8
–
17.0
–
200
–
250
35.9
41.1
38.8
24.0
–
17.1
–
35.0
–
16.0
–
27.0
33.1
FutureCom F
Min. ACR in dB*
65.0
5.5
62.5
–
– 2.8
11.8
15.3
FutureCom 10TEN
72.2
Min. NEXT in dB*
2.1
20
–
33.3
8.0
15.0
FutureCom E
NEXT in dB (typ. FutureCom E values)
Attenuation in dB (typ. FutureCom™ E values)
10
–
FutureCom D
The system values cited only apply to the use of original FutureCom E products. Derived values, such as PSACR, PSNEXT,
PSELFEXT, are in observance of the standard values, but are not shown.
Attenuation and
Near-end Crosstalk (NEXT)
NEXT in dB
(typ. FutureCom E values)
min. NEXT in dB
According to standard
max. Attenuation in dB
According to standard
Attenuation in dB
(typ. FutureCom E values)
Further
Information
Special
Cable
Industrial
Cable
Frequency in MHz
FutureCom UD FutureCom UE
1
4.0
Hardware
Max. attenuation in dB*
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Frequency in MHz
Introduction
FutureCom™ E System Data
for Channel Class E (2002)
Corning Cable Systems
57
FutureCom™ E System Data
Far-end Crosstalk Relating
to the Far End (ELFEXT)
ELFEXT in dB
(typ. FutureCom™ E values)
Min. ELFEXT in dB
According to standard
Frequency in MHz
Return Loss
Return loss in dB
(typ. FutureCom E values)
min. Return loss in dB
According to standard
Frequency in MHz
Test Setup
FutureCom E Test Cable, 2xRJ45, 3 m
Nominal intrinsic impedance
100 V
S250 Patch Panel 19“
Max. delay (according to standard)
0.05 µs
S250 Module, 2xRJ45
90 m FutureCom S/FTP900/23
FutureCom E Test Cable, 2 x RJ45, 3 m
58
Max. DC loop resistance (according to standard)
DC loop resistance (typ. FutureCom E values)
Max. delay (typ. FutureCom E values)
Corning Cable Systems
40 V
18 V
, 0.02 µs
Further
Information
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
FutureCom 10TEN
FutureCom F
Introduction
FutureCom™ E Certificate
4-Connector Channel
Corning Cable Systems
59
FutureCom™ E Certificate
3-Connector Permanent Link
60
Corning Cable Systems
Foil shielding (PiMF)
FutureCom cables are low-skew products. This is increas-
PE foam-skin insulation
suitability of the cable for utilization up to the GHz area
enables the highest possible transmission speeds in futureproof networks. These cables have a streamlined construction and low weight.
Each pair is individually shielded (PiMF). The stranded pairs
are additionally braid shielded (S/FTP) which guarantees
outstanding shielding characteristics. The cable satisfies
Class B interference radiation standards (EN 55022) as well
as immunity (EN 55024) which enables the realization of
CE-compatible networks.
The FutureCom S/FTP 900/23 and 600/23 cables are also
available in a triplex version. The compact construction
allows flat as well as folded installation.
Further
Information
Copper conductor
AWG 23
ingly required for applications above 1 Gigabit-Ethernet. The
FutureCom UD FutureCom UE
tions.
Twisted pair
Hardware
transmission characteristics exceed Category 7 specifica-
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
designed for applications up to 1000/800 MHz and their
Industrial
Cable
The FutureCom™ S/FTP 900/23 and S/FTP 600/23 cables are
Halogen-free jacket,
flame retardant
Special
Cable
Application
Braided shield
4 shielded pairs
FutureCom D
FutureCom E
FutureCom 10TEN
FutureCom F
Introduction
FutureCom™ E Cat. 7+ and Cat.7 Cables
S/FTP 900/23 and S/FTP 600/23
Corning Cable Systems
61
FutureCom™ E Cat. 7+ and Cat.7 Cables
S/FTP 900/23 and S/FTP 600/23
Features
S/FTP 900/23 specified up to 1000 MHz,
S/FTP 600/23 specified up to 800 MHz
Outstanding electrical characteristics
Easy and convenient installation on double and triple
outlets
Compact installation of the triple cable either flat or
folded (øonly 16.3 mm)
Each pair is individually foil shielded
Full braid shield
Low skew between the pairs
Halogen-free (LSZH)
Flame retardant according to IEC 60332-3, Category C
Non-corrosive according to IEC 60754-2 (FRNC)
Low smoke according to IEC 61034
Mechanical Characteristics
Conductor insulation
Outer jacket
Area/range of application
Temperature range (installation)
Halogen-free
Foam-skin material
Halogen-free,
flame retardant
Dry and
damp rooms
0 to +50°C
Min. bending radius
-20 to +60°C
>_ 40 mm (for 2 or 3x
installation
(4x2...) over flat side)
Operating temperature
for one-time bending
Min. bending radius during
Copper conductor
62
(4x2...) over flat side)
>_ 60 mm (for 2 or 3x
AWG 23
Electrical Characteristics (at 20°C)
Largest resistance margin
Insulation resistance
Impedance Zo at 0.064 MHz
Impedance Zo at 1 - 100 MHz
Impedance Zo at 101 - 250 MHz
Impedance Zo at 251 - 600 MHz
Surface transfer impedance
1%
>5000 mV x km
125 V +/– 20%
100 V +/– 15%
100 V +/– 18%
100 V +/– 25%
<10 m V/m
at 10 MHz
Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz
Unbalance to ground dB/BZL = 100 m
Unbalance to ground dB/BZL = 100 m
Propagation velocity
at > 10 MHz (NVP x c)
Propagation delay >_ 10 MHz
Delay skew
Corning Cable Systems
>40 dB at 1 MHz
>20 dB at 100 MHz
0.79 x c
4.2 ns/m
4 ns/100 m
65.3
60.8
Attenuation in dB/100m *
2.0
Typical values in dB at 100 m
>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0
Typical values dB/100m
1.7
NEXT in dB at 100 m *
80.0
PSNEXT in dB at 100 m *
77.0
Typical values in dB at 100m
98.0
ELFEXT in dB at 100 m *
80.0
Typical values in dB at 100m
93.0
PSELFEXT in dB at 100 m *
77.0
Typical values in dB at 100m
91.0
5.7
7.2
5.0
6.5
77.0
77.0
98.0
98.0
74.0
69.9
93.0
93.0
71.0
66.9
91.0
91.0
8.1
7.3
80.0
77.0
98.0
68.0
93.0
65.0
91.0
10.1
14.5
9.2
13.2
80.0
75.1
77.0
72.5
98.0
98.0
64.1
58.1
90.0
86.0
61.1
55.1
88.0
84.0
18.5
33.3
16.8
30.0
72.4
69.4
62.3
98.0
94.0
54.0
44.5
83.0
68.0
51.0
41.5
81.0
66.0
48.9
42.5
92.0
57.8
90.0
38.4
51.0
35.4
49.0
900
55.0
–
86.0
–
84.0
–
–
1000
59.0
–
83.0
–
81.0
–
–
–
–
–
–
–
–
ACR in dB
98.3 95.0 93.5
92.7
90.8 86.8 83.2
66.0 49.5 31.0
24.0
* Standard: Requirements on 100 m of installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
Electrical Characteristics (at 20°C) for S/FTP 600/23
1
Frequency in MHz
10
16
20
31.25
62.5
100
Attenuation in dB/100m *
2.0
Typical values in dB at 100m
>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0
Typical values dB/100m
5.7
1.7
NEXT in dB at 100 m *
5.0
80.0
PSNEXT in dB at 100 m *
80.0
77.0
Typical values in dB at 100m
77.0
98.0
ELFEXT in dB at 100 m *
98.0
80.0
Typical values in dB at 100m
74.0
93.0
PSELFEXT in dB at 100 m *
93.0
77.0
Typical values in dB at 100m
71.0
91.0
ACR in dB
91.0
98.3
95.0
7.2
6.5
80.0
77.0
98.0
69.9
93.0
66.9
91.0
93.5
8.1
7.3
80.0
77.0
98.0
68.0
93.0
65.0
91.0
92.7
10.1
9.2
80.0
77.0
98.0
64.1
90.0
61.1
88.0
90.8
14.5
18.5
13.2
72.4
72.5
98.0
58.1
86.0
55.1
84.0
86.8
69.4
97.0
54.0
83.0
51.0
81.0
82.1
600
65.3
60.8
33.3
16.8
75.1
300
30.7
95.0
62.3
93.0
44.5
68.0
41.5
66.0
64.3
48.9
44.0
91.0
57.8
89.0
38.4
51.0
35.4
49.0
47.0
800
53.0
–
87.0
–
85.0
–
–
–
–
34.0
–
* Standard: Requirements on 100 m of installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
Ordering Information
Type designation
Max.
Outer [ Weight Length
Fire Load Halogen- Tensile
Order Number
Category No. of Pairs (MJ/m) free
Strength(N) (mm) (kg/km) (m)
S/FTP 900/23 4P
7+
S/FTP 900/23 4P
S/FTP 900/23 8P
S/FTP 900/23 12P
S/FTP 600/23 4P
S/FTP 600/23 4P
S/FTP 600/23 8P
S/FTP 600/23 12P
7+
4
0.63
Yes
154
7.7
7+
12
1.89
Yes
462
7.7x25.0 195
7+
7
7
7
7
4
8
4
4
8
12
0.63
1.26
0.63
0.63
1.26
1.89
Yes
Yes
Yes
Yes
Yes
Yes
154
308
154
154
308
462
7.7
64
64
7.7x16.5 130
7.7
7.7
64
64
7.7x16.5 130
7.7x25.0 195
* X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.
Corning Cable Systems
1000
CCXEDB-I0047-C001-L7
500
CCXEDB-I0127-C001-L6
250
500
1000
250
500
500
CCXEDB-I0047-C001-X2*
CCXEDB-I0087-C001-L6
CCXEDB-F0047-C001-L7
CCXEDB-F0047-C001-X2*
CCXEDB-F0087-C001-L6
CCXEDB-F0127-C001-L6
63
FutureCom F
600
FutureCom 10TEN
300
FutureCom E
100
FutureCom D
62.5
FutureCom UD FutureCom UE
80.0
31.25
Hardware
80.0
20
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
16
Industrial
Cable
10
Special
Cable
1
Frequency in MHz
Further
Information
Electrical Characteristics (at 20°C) for S/FTP 900/23
Introduction
FutureCom™ E Cat. 7+ and Cat.7 Cables
S/FTP 900/23 and S/FTP 600/23
FutureCom™ E Cat. 6 Cables
S/FTP 450/23
Braided shield
Halogen-free jacket,
flame retardant
Twisted pair
Foil shielding (PiMF)
4 shielded pairs
PE foam-skin insulation
Copper conductor
AWG 23
Application
The FutureCom™ S/FTP 450/23 cables are designed for
applications of up to 600 MHz and their transmission
characteristics exceed Category 6 specifications.
FutureCom cables are low-skew products, i.e. the skew
between the individual pairs are very low. This is increasingly required for Gigabit-Ethernet. These cables have a
streamlined construction and low weight.
Each pair is individually shielded (PiMF). The stranded pairs
are additionally braid shielded (S/FTP), which guarantees
outstanding shielding characteristics. The cables satisfies
Class B interference radiation standards (EN 55022), as well
as immunity (EN 55024), which enables the realization of
CE-compatible networks.
Mechanical Characteristics
Conductor insulation
Outer jacket
Area/range of application
Temperature range (installation)
Operating temperature
Halogen-free
Foam-skin material
Halogen-free,
flame retardant
Dry and
damp rooms
0 to +50°C
Full braid shield
Streamlined design
Lightweight
Low skew between the pairs
Low smoke according to IEC 61034
(4x2...) over flat side)
64
Each pair is shielded (PiMF)
>_ 60 mm (for 2 x
installation
Copper conductor
Outstanding electrical characteristics
Halogen-free (LSZH)
>_ 40 mm (for 2 x
Min. bending radius during
S/FTP 450/23, specified up to 600 MHz
-20 to +60°C
Min. bending radius
for one-time bending
Features
(4x2...) over flat side)
AWG 23
Flame retardant according to IEC 60332-3, Category C
Non-corrosive according to IEC 60754-2 (FRNC)
Corning Cable Systems
Electrical Characteristics (at 20°C)
Largest resistance margin
Introduction
FutureCom™ E Cat. 6 Cables
S/FTP 450/23
1%
Insulation resistance
>5000 MV x km
Impedance Zo at 0.064 MHz
125 V +/– 20%
Impedance Zo at 1 - 100 MHz
100 V +/– 18%
Unbalance to ground dB/BZL = 100 m
>40 dB at 1 MHz
Surface transfer impedance
FutureCom F
100 V +/– 15%
Impedance Zo at 101 - 250 MHz
<10 mV/m at 10 MHz / S/FTP
Unbalance to ground dB/BZL = 1000 m
Unbalance to ground dB/BZL = 100 m
FutureCom 10TEN
>46 dB at 64 kHz
>20 dB at 100 MHz
Propagation velocity at > 10 MHz (NVP x c)
Propagation delay >_ 10 MHz
0.79 x c
FutureCom E
4.2 ns/m
Delay skew
20
31.25
62.5
100
Attenuation in dB/100m *
2.1
Typical values in dB at 100 m
>100.0 >100.0 >100.0 >100.0 >100.0 97.0
Typical values dB/100m
6.0
1.8
NEXT in dB at 100 m *
5.3
66.0
PSNEXT in dB at 100 m *
59.3
64.0
Typical values in dB at 100m
57.3
98.0
ELFEXT in dB at 100 m *
98.0
66.0
Typical values in dB at 100m
50
93.0
PSELFEXT in dB at 100 m *
93.0
64.0
Typical values in dB at 100m
47
91.0
ACR in dB
91.0
98.2
94.7
7.6
6.8
56.2
54.2
98.0
45.9
93.0
41.0
91.0
93.2
8.5
7.6
54.8
52.8
98.0
44.0
93.0
41.0
91.0
92.4
10.8
9.6
51.9
49.9
98.0
40.1
90.0
37.1
88.0
90.4
15.5
13.6
47.4
45.4
95.0
34.1
86.0
31.1
84.0
83.4
250
19.9
33.0
95.0
90.0
17.3
44.3
42.3
93.0
30.0
83.0
27.0
81.0
77.7
27.7
38.3
36.3
88.0
22.0
70.0
19.0
68.0
62.3
450
38.0
–
85.0
–
83.0
–
54.0
–
52.0
–
47.0
600
44.8
–
75.0
–
73.0
–
48.0
–
46.0
–
30.2
* Standard: Requirements on 100 m of installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1)
Type designation
Max.
Outer [ Weight Length
Fire Load Halogen- Tensile
Category No. of Pairs (MJ/m) free
Order Number
Strength(N) (mm) (kg/km) (m)
S/FTP 450/23 4P
6
S/FTP 450/23 4P
S/FTP 450/23 8P
6
6
4
4
8
0.57
0.57
1.14
Yes
Yes
Yes
145
145
290
7.9
7.9
55
55
7.5x16.6 120
* X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.
Corning Cable Systems
1000
250
500
Industrial
Cable
Ordering Information
FutureCom UD FutureCom UE
16
Hardware
10
Flex Wire
Flex Wire
CableCable
Telephone /
for Patch
for Patch
Cord Cord
ISDN Products
1
CCXEDB-D0047-C001-L7
CCXEDB-D0047-C001-X2*
CCXEDB-D0087-C001-L6
65
Special
Cable
Frequency in MHz
Further
Information
Electrical Characteristics (at 20°C)
FutureCom D
4 ns/100 m
FutureCom™ E Cat. 6 Cables
F/FTP 450/23
Foil shield (FTP)
Halogen-free jacket,
flame retardant
Twisted pair
Foil shielding (PiMF)
4 shielded pairs
Additional wire
PE foam-skin insulation
Copper conductor
AWG 23
Mechanical Characteristics
Conductor insulation
Outer jacket
Area/range of application
Temperature range (installation)
Operating temperature
Halogen-free
Foam-skin material
Halogen-free,
flame retardant
Dry and
damp rooms
0 to +50°C
FutureCom cables are low-skew products, i.e. the skew
between the individual pairs are very low. This is increasingly required for Gigabit-Ethernet. These cables have a
streamlined construction and low weight.
Each pair is individually shielded (PiMF). The stranded pairs
are additionally foil shielded (F/FTP), which guarantees out-
standing shielding characteristics. The cables satisfies Class
B interference radiation standards (EN 55022), as well as im-
munity (EN 55024), which enables the realization of CE-compatible networks.
Features
F/FTP flex cable, specified up to 450 MHz
Outstanding electrical characteristics
Each pair is shielded (PiMF)
Full foil shielding and additional copper wire
Streamlined design
Lightweight
Low skew between the pairs
Low smoke according to IEC 61034
(4x2...) over flat side)
66
characteristics exceed Category 6 specifications.
>_ 60 mm (for 2 x
installation
Copper conductor
applications of up to 450 MHz and their transmission
Halogen-free (LSZH)
>_ 40 mm (for 2 x
Min. bending radius during
The FutureCom™ F/FTP 450/23 cables are designed for
-20 to +60°C
Min. bending radius
for one-time bending
Application
(4x2...) over flat side)
AWG 23
Fire retardant according to IEC 60332-3, Category C
Non-corrosive according to IEC 60754-2 (FRNC)
Corning Cable Systems
Electrical Characteristics (at 20°C)
Largest resistance margin
Introduction
FutureCom™ E Cat. 6 Cables
F/FTP 450/23
2%
Insulation resistance
>5000 MV x km
Impedance Zo at 0.064 MHz
125 V +/– 20%
Impedance Zo at 1 - 100 MHz
100 V +/– 18%
Unbalance to ground dB/BZL = 100 m
>40 dB at 1 MHz
Surface transfer impedance
FutureCom F
100 V +/– 15%
Impedance Zo at 101 - 250 MHz
100 mV/m at 10 MHz
Unbalance to ground dB/BZL = 1000 m
Unbalance to ground dB/BZL = 100 m
FutureCom 10TEN
>46 dB at 64 kHz
>20 dB at 100 MHz
Propagation velocity at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
0.79 x c
FutureCom E
4.3 ns/m
Delay skew
20
59.3
56.2
54.8
31.25
62.5
100
250
51.9
47.4
44.3
38.3
Attenuation in dB/100m *
2.1
Typical values in dB at 100 m
>100.0 >100.0 >100.0 >100.0 >100.0 97.0
Typical values dB/100m
1.8
NEXT in dB at 100 m *
66.0
PSNEXT in dB at 100 m *
64.0
Typical values in dB at 100m
98.0
ELFEXT in dB at 100 m *
66.0
Typical values in dB at 100m
93.0
PSELFEXT in dB at 100 m *
64.0
Typical values in dB at 100m
91.0
ACR in dB
98.2
6.0
5.3
57.3
98.0
50
93.0
47
91.0
94.7
7.6
6.8
54.2
98.0
45.9
93.0
41.0
91.0
93.2
8.5
7.6
52.8
98.0
44.0
93.0
41.0
91.0
92.4
10.8
9.6
49.9
98.0
40.1
90.0
37.1
88.0
90.4
15.5
13.6
45.4
95.0
34.1
86.0
31.1
84.0
83.4
19.9
17.3
95.0
42.3
93.0
30.0
83.0
27.0
81.0
77.7
33.0
27.7
90.0
36.3
88.0
22.0
70.0
19.0
68.0
62.3
450
38.0
–
85.0
–
83.0
–
54.0
–
52.0
–
47.0
* Standard: Requirements on 100 m of installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1)
Type designation
Max.
Outer [ Weight Length
Fire Load Halogen- Tensile
Category No. of Pairs (MJ/m) free
Order Number
Strength(N) (mm) (kg/km) (m)
F/FTP 450/23 4P
6
F/FTP 450/23 4P
F/FTP 450/23 8P
6
6
4
4
8
0.57
0.57
1.16
Yes
Yes
Yes
105
105
210
7.4
7.4
50
50
7.4x15.5 100
* X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.
Corning Cable Systems
1000
250
500
Industrial
Cable
Ordering Information
FutureCom UD FutureCom UE
16
Hardware
10
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
1
CCXDDA-D0047-C001-L7
CCXDDA-D0047-C001-X2*
CCXDDA-D0087-C001-L6
67
Special
Cable
Frequency in MHz
Further
Information
Electrical Characteristics (at 20°C)
FutureCom D
4 ns/100 m
FutureCom™ E
Module Overview
Features
Fully compatible with all modular LANscape® systems
Wide range of installation options
Few individual components
High-level component density
Individual shielding
Halogen-free
Fire class UL94V-0
Optimized construction with printed circuit board for
bandwidths of more than 300 MHz
1500 connector cycles are possible
Proven IDC technology for wires with AWG 24 to AWG 22
Module reusable several times
Individual Components of the S250 Module
Disassembled S250 Basic Module
Features
Wire management using TIA/EIA 568 A/B coding
Installation in pairs
(no untwisting of the pairs necessary)
Rapid assembly time
Easy handling
Compatible with all FutureCom™ S/FTP and F/FTP cables
Wire Management
68
Corning Cable Systems
Further
Information
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
FutureCom 10TEN
FutureCom F
Introduction
FutureCom™ E Certificate
Cat.6 De-embedded for S250 Modules
Corning Cable Systems
69
FutureCom™ E
S250 Module
Features
Easy and quick to install, no special tools required
IDC connection (IDC = Insulation Displacement Contacts)
High-level component density
Universal usage in all modular LANscape® and
FutureCom™ components
Category 6 (2002), de-embedded
Ordering Information
Order Number
CAXESM-00100-C001
Description
S250 Module, 1xRJ45, shielded, Cat.6,
incl. copper conducting tape for installation
in LANscape modular patch panels,
Unit per
Delivery
1/1
outlets and floor box solutions
CAXESM-00200-C001
S250 Double Module, 2xRJ45, shielded, Cat.6,
incl. copper conducting tape for installation
in LANscape modular patch panels,
1/1
outlets and floor box solutions
Cable Strain Relief
Using the additional cable strain relief allows increased pulling force on the module housings.
Order Number
CAXCSN-00000-C001
Description
Additional cable strain relief,
for higher pulling force on shielded
FutureCom modules for solid wire,
and for assembly of flexible consolidation
point cables with FutureCom S10TEN fx,
S250fx or U250fx modules
70
Corning Cable Systems
Unit per
Delivery
100/1
FutureCom™ E
S250fx Module
Introduction
Application
S250fx Modules are used for the assembly of flexible cables
or consolidation point cables.
FutureCom F
Features
Fully compatible with all modular LANscape® connecting
Individual shielding
Proven IDC technology for AWG 24 and AWG 26 stranded
Individual components of the S250fx Module
1500 connector cycles are possible
Wire management using A/B printing according to
TIA/EIA 568
Installation in pairs (no untwisting of the pairs is
necessary)
Category 6, de-embedded
FutureCom UD FutureCom UE
Easy handling and very short assembly time
Requirements for Consolidation Points
For the assembly of modules with flexible cables,
an additional cable strain relief must be used
CCS patch cords (with RJ45 connectors) are wired
according to TIA/EIA 568 B; when using other single-
ended pre-terminated connecting cables they should be
Ordering Information
S250fx Module, 1xRJ45, shielded, Cat.6,
especially suitable for consolidation point
cable with AWG 24/26 stranded wires,
Unit per
Delivery
1/1
incl. copper conducting tape and
Special
Cable
CAXESM-00100-C003
Description
additional cable strain relief for installation in
LANscape hardware
Further
Information
Order Number
attenuation specification than the flexible cable
Industrial
Cable
Assembled S250fx Module
with Additional Cable Strain Relief
wired according to the RJ45 connector scheme
The installed solid wire cable should have a lower
Hardware
Module reusable several times
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
wires
FutureCom D
Wide range of installation options
FutureCom E
FutureCom 10TEN
hardware
Corning Cable Systems
71
FutureCom™ E
S250 Outlets and Patch Panel
Ordering Information
S250 Outlets
Order Number
Description
S250 Outlet, 2xRJ45,
shielded, Cat. 6, inclined,
Unit per
Delivery
incl. mounting frame
with grounding flaps,
central plate 50x50 mm
with designation window,
screw-fixed, copper
CAXESD-S0201-C001
CAXESD-S0202-C001
S250 Patch Panel
Order Number
CAXESV-02400-C001
conducting tape
(without face plate)
white, RAL 9010
1/1
pearl white, RAL 1013
1/1
Description
Unit per
Delivery
S250 Patch Panel 19“,
shielded, Cat. 6, including
24 FutureCom S250
1/1
modules and copper
conducting tape,
with integrated
cable strain relief,
1 U, high-grade steel
front panel
Patch panel accessories please see page 156.
72
Corning Cable Systems
Order Number
CAXESD-S0200-C001
Description
S250 Double Module Outlet,
2xRJ45, Cat. 6, inclined,
incl. mounting frame with
Unit per
Delivery
1/1
FutureCom F
Ordering Information
Introduction
FutureCom™ E
S250 Double Module Outlet
grounding flaps and
FutureCom 10TEN
copper conducting tape
(suitable for Rutenbeck-
compatible central plates
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
or faceplates)
Installation Option
S250 Double Module Outlet, 2xRJ45, Cat. 6, inclined,
incl. mounting frame and copper conducting tape.
Hardware
CAXESD-S0200-C001
For example, mounted with a high grade steel face plate
Further
Information
Special
Cable
S250 Double Module Outlet with face plate (Jung)
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
from Jung
Corning Cable Systems
73
FutureCom™ E
Outlet Installation Options
Option 1: 6-Port Frame Set for the installation of 6
LANscape® fiber optic or FutureCom™ modules, inclined, in-
cluding mounting frame and two triple housings with designation window and dust protection flaps as well as 151x80
mm face plate, white, RAL 9010:
WAXWSE-V0601-C001
equipped with two S250 modules
CAXESM-00100-C001
two black labeling icons
WAXWSE-00008-C001
four blue labeling icons
WAXWSE-00004-C001
6-Port Frame Set, inclined
and two blue S/FTP flex/26 Patch Cords
CCAEGB-D2002-A030-C0
Option 2: S250 Inclined Outlet with two S250 Modules,
white, RAL 9010 in the race-way:
CAXESD-S0201-C001
equipped with one black labeling icon
WAXWSE-00008-C001
and one blue labeling icon
WAXWSE-00004-C001
Built into a Tehalit race-way
S250 Inclined Outlet with two S250 Modules
Option 3: Double Surface Outlet for the mounting of 2 LAN-
scape modules, inclined, including face plate and double
housing with designation window and dust protection
flaps, white, RAL 9010:
WAXWSE-V0201-C001
equipped with two S250 modules
CAXESM-00100-C001
one gray labeling icon
WAXWSE-00003-C001
one green labeling icon
WAXWSE-00006-C001
and one green S/FTP flex/26 Patch Cord
2-Port Surface Mount Outlet
CCAEGB-D4002-A020-C0
using one surface mount housing
WAXWSE-00001-C003
... and one “DELTAfläche” face plate
74
Corning Cable Systems
FutureCom™ E
Cat. 6 Patch Cords RJ45 to RJ45
Introduction
Description
The FutureCom E System patch cords consist of Category 6
flex cable with shielded RJ45 connectors at both ends. The
flex cables have four individual foil-shielded pairs and full
FutureCom F
braid copper shielding. The zero halogen patch cords (LSZH)
are non-corrosive (according to IEC 60754-2), low smoke
(according to IEC 61034) and flame retardant (according to
FutureCom 10TEN
IEC 60332-1, Category B). They are available in various
lengths and colors.
FutureCom E
Features
FutureCom D
S/FTP flex cable, specified up to 600 MHz
Application-neutral due to using all four pairs
Minimum surface transfer impedance
(<10 mV/m at 10 MHz)
FutureCom UD FutureCom UE
Outstanding transmission characteristics according to
Channel E (2002)
1
2
3
4
5
6
=
=
=
=
=
=
gray
blue
yellow
green
red
black
2
2
- C0
Select length.
010
015
020
030
040
050
060
075
080
100
150
200
250
300
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1 meter
1.5 meters
2 meters
3 meters
4 meters
5 meters
6 meters
7.5 meters
8 meters
10 meters
15 meters
20 meters (gray only)
25 meters (gray only)
30 meters (gray only)
Corning Cable Systems
Industrial
Cable
Select color.
002 - A
Special
Cable
1
1
Further
Information
CCAEGB - G
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Ordering Information
Hardware
Cat. 6
75
FutureCom™ E
Consolidation Point Patch Cords
Description
The FutureCom™ E Consolidation Point Patch Cords are
factory terminated cable assemblies with one S250 fx
module and one RJ45 connector. FutureCom S/FTP flex/26
Cable is specified up to 600 MHz and satisfies Category 7
transmission characteristics. The CP Patch Cords are suitable
to connect LANscape® Consolidation Point Housings to wall
or desktop outlets.
Ordering Information
Order Number
Description
S/FTP flex/26 Patch Cords,
4 pairs, application-neutral, FRNC sheath,
Length
gray, pre-terminated with one RJ45
CCAEGB-D1052-A050-C0
CCAEGB-D1052-A100-C0
CCAEGB-D1052-A150-C0
CCAEGB-D1052-A200-C0
Other lengths upon request
76
connector and one S250fx module, Cat. 6,
for example 10/100/1000Base-T
CP Patch Cords S/FTP flex/26 - 5
CP Patch Cords S/FTP flex/26 - 10
CP Patch Cords S/FTP flex/26 - 15
CP Patch Cords S/FTP flex/26 - 20
Corning Cable Systems
5m
10 m
15 m
20 m
FutureCom™ E
Plug & Play™ Solutions
Introduction
Application
The S250 Solution Packages are pre-terminated cables with
S250 modules at both ends. They are generally offered with
FutureCom F
FutureCom™ S/FTP 900/23 cables. Both modules are
equipped with additional cable strain relief, to allow higher
pulling forces during insertion (the pulling force is restricted
FutureCom 10TEN
by the cable only). They enable Plug and Play™ installation
CCAEDB-D2050-A250-C0
CCAEDB-D2050-A300-C0
CCAEDB-D2050-A350-C0
CCAEDB-D2050-A400-C0
CCAEDB-D2050-A450-C0
CCAEDB-D2050-A500-C0
CCAEDB-D2050-A550-C0
CCAEDB-D2050-A600-C0
CCAEDB-D2050-A650-C0
CCAEDB-D2050-A700-C0
CCAEDB-D2050-A750-C0
CCAEDB-D2050-A800-C0
CCAEDB-D2050-A850-C0
CCAEDB-D2050-A900-C0
with 2 S250 modules
and additional cable strain relief
S250 Solution Package S/FTP 900/23 - 10
10 m
S250 Solution Package S/FTP 900/23 - 25
25 m
S250 Solution Package S/FTP 900/23 - 15
S250 Solution Package S/FTP 900/23 - 20
S250 Solution Package S/FTP 900/23 - 30
S250 Solution Package S/FTP 900/23 - 35
15 m
20 m
30 m
35 m
S250 Solution Package S/FTP 900/23 - 40
40 m
S250 Solution Package S/FTP 900/23 - 55
55 m
S250 Solution Package S/FTP 900/23 - 70
70 m
S250 Solution Package S/FTP 900/23 - 45
S250 Solution Package S/FTP 900/23 - 50
S250 Solution Package S/FTP 900/23 - 60
S250 Solution Package S/FTP 900/23 - 65
S250 Solution Package S/FTP 900/23 - 75
S250 Solution Package S/FTP 900/23 - 80
S250 Solution Package S/FTP 900/23 - 85
S250 Solution Package S/FTP 900/23 - 90
45 m
50 m
60 m
65 m
75 m
80 m
85 m
90 m
Hardware
CCAEDB-D2050-A200-C0
4 pairs, FRNC jacket pre-terminated
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
CCAEDB-D2050-A150-C0
Solution Package, S/FTP900/23 cable,
Length
Industrial
Cable
CCAEDB-D2050-A100-C0
Description
Further
Information
Order Number
Special
Cable
Ordering Information
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
and therefore significantly reduce installation time.
Corning Cable Systems
77
FutureCom™ E
Plug & Play™ Solutions
Application
The S250 Plug and Play™ Solution has been especially created for use in data center applications. This special
assembly consists of six S/FTP 900/23 cables, with a com-
mon FRNC jacket. The cable is pre-terminated with six S250
modules at both ends. All modules are equipped with addi-
tional cable strain relief, to allow higher pulling force during
installation (the pulling force is restricted by the cable only).
They enable rapid Plug and Play installation in data centers
and therefore significantly reduce installation time. 100%
factory testing reduces failures during installation.
Ordering Information
Order Number
Description
S250 Plug & Play Solution Package, with
6x S/FTP 900/23 cables with common
Length
FRNC jacket, both ends terminated
CCAEDB-D2650-A200-C0
CCAEDB-D2650-A300-C0
CCAEDB-D2650-A400-C0
with 6 S250 modules,
and additional cable strain relief
S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 20
S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 30
S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 40
Other lengths available upon request.
Installation Option
20 m
30 m
40 m
S250 Plug & Play Solution Package, with 6x S/FTP 900/23
cables with common FRNC jacket, both ends terminated
with 6 S250 modules, and additional cable strain relief:
CCAEDB-D2650-A200-C0
installed in a CCHE Empty Panel for 6 LANscape modules
CCHE-CP00-LS
CCHE Panel with Plug & Play Solution Package
78
Corning Cable Systems
FutureCom™ E
Universal Test Cord for Channel Testing
Introduction
Application
The universal channel test cord can be used for acceptance
tests of shielded FutureCom™ E Systems in conjunction with
the universal test adapter from Fluke or other test device
FutureCom F
manufactureres.
of the FutureCom E System in conjunction
with the universal test adapter from Fluke
FutureCom E
Universal Test Cord, for the acceptance test
Units per
Delivery
1/1
or other test device manufacturers,
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
2xRJ45, 4 pairs, 3 m
Special
Cable
CCAEGB-D10M0-A030-C0
Description
Further
Information
Order Number
FutureCom D
Ordering Information
FutureCom 10TEN
One pair of these test cords is required for acceptance tests.
Corning Cable Systems
79
80
Corning Cable Systems
5.3.1. Cat. 5 SF/UTP 300/24 FRNC/PVC Cable
86
5.3.3. Cat. 5 F/UTP 300/24 FRNC/PVC Cable
90
5.4.1. S100e Module Overview
92
5.3.2. Cat. 5 SF/UTP 300/24 FRNC, 16P Cable
5.4. Connecting Hardware
5.4.2. S100e and S100eL Module
88
93
5.5. Hardware
5.5.1. S100e Outlets and Patch Panels
94
5.5.3. S100eL Outlets and Patch Panels
96
5.5.2. S100e Double Module Outlet
95
5.5.4. Installation Options for Outlets
97
5.6. Patch Cords
98
99
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
5.7. Plug & Play™
FutureCom F
5.3. Cable
FutureCom 10TEN
85
FutureCom E
5.2. Certificates
FutureCom D
82
FutureCom UD FutureCom UE
5.1. System Descriptions & Data
Hardware
FutureCom D
Further
Information
5
Introduction
Table of contents
Corning Cable Systems
81
FutureCom™ D System
FutureCom D (2002) is Corning’s Class D system solution for symmetrical cabling. It fulfils all requirements of the current
ISO/IEC 11801 (2002) and EN 50173-1 (2003) standards, Class D for links and Category 5 for the components. In addition,
the FutureCom D system also satisfies Category 5e according to TIA/EIA-568-A-5.
Face Plate
“DELTAprofil”,
80x80 mm
WAXWSE-00001-C001
and
S100e outlet, 2xRJ45,
Cat.5, inclined,
CAXDSD-S0201-C001
SF/UTP flex/26, green,
2xRJ45 connectors,
4 pairs,
for 10/100/1000Base-T
CCADGF-D4002-A030-C0
FutureCom
SF/UTP 300/24 Cable
CCXDEF-I0047-C001-L7
19“ Patch Panel, for
max. 24 LANscape®
modules,
with integrated cable
strain relief, 1 U,
front panel of
high-grade steel
WAXWSV-02400-C001
S100e Module,
1xRJ45, shielded,
Cat. 5
CAXDSM-00100-C001
SF/UTP flex/26, green,
2xRJ45- connectors,
4 pairs, for
10/100/1000 Base-T
CCADGF-D4002-A020-C0
A high level of system performace is achieved for the entire
FutureCom D cabling that conforms to the standards is
mace, and future security, guarantees a high degree of
mission, ISDN, Token Ring, Ethernet (10-Base-T), Ethernet
link through the use of high-quality Category 5 connection
technology, cables and patch cords. The resulting perforinvestment protection for the cabling.
Fully configured with RJ45 connectors and RJ45 modules, the
cabling is application-neutral and can be used universally.
82
suitable for all recognized standardized voice and data
transmission procedures. This applies to analog voice trans(100Base-TX) and Gigabit Ethernet (1000Base-T).
The performance of the FutureCom D cabling system has
been certified by an independent test body (see certificate).
Of course, all standardized EMC threshold values in Europe
are observed.
Corning Cable Systems
ACR in dB (typ. FutureCom D values)
Min. ELFEXT in dB*
ELFEXT in dB (typ. FutureCom D values)
Min. return loss in dB*
Return loss in dB (typ. FutureCom D values)
* According to ISO/IEC 11801 (2002)
70.0
56.0
67.7
57.4
70.0
17.0
19.0
60.0
–
56.5
–
60.0
–
20.0
–
55.0
–
49.2
–
52.0
–
20.0
–
43.6
51.0
34.5
44.0
33.3
48.0
17.0
20.0
8.5
–
48.0
–
39.2
–
46.0
–
19.5
–
10.0
–
44.0
–
34.0
–
43.0
–
19.0
–
62.5
16.0
–
38.0
–
22.0
–
38.0
–
17.0
–
100
24.0
19.0
30.1
36.0
6.1
17.0
17.4
34.0
10.0
13.0
The system values cited are only valid with regard to the use of original FutureCom D products. Derived values,
such as PSACR, PSNEXT and PSELFEXT, maintain the required standard values but are not shown for clarity of presentation.
Attenuation and
Near-end Crosstalk (NEXT)
NEXT in dB
(typ. FutureCom D values)
min. NEXT in dB
According to standard
max. Attenuation in dB
According to standard
Attenuation in dB
(typ. FutureCom D values)
Further
Information
Special
Cable
Industrial
Cable
Frequency in MHz
FutureCom F
Min. ACR in dB*
60.0
7.0
9.1
31.25
FutureCom 10TEN
NEXT in dB (typ. FutureCom D values)
5.8
–
20
FutureCom E
Min. NEXT in dB*
3.5
–
16
FutureCom D
2.3
4.0
10
FutureCom UD FutureCom UE
Attenuation in dB (typ. FutureCom™ D values)
Max. attenuation in dB*
4
Hardware
1
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Frequency in MHz
Introduction
FutureCom™ D System Data
for Channel Class D (2002)
Corning Cable Systems
83
FutureCom™ D System Data
Far-end Crosstalk Relating
to the Far End (ELFEXT)
ELFEXT in dB
(typ. FutureCom™ D values)
Min. ELFEXT in dB
According to Norm
Frequency in MHz
Return Loss
Return loss in dB
(typ. FutureCom D values)
min. return loss in dB
according to standard
Frequency in MHz
Test Setup
FutureCom™ D SF/UTP flex/26 Connecting Cable, 3 m
S100e Modules, 2xRJ45
90 m FutureCom SF/UTP300/24
S100e Patch Panel 19“
FutureCom D SF/UTP flex/26 Patch Cord, 3 m
84
Nominal intrinsic impedance
100 V
Max. delay (according to standard)
0.05 µs
Max. DC loop resistance (according to standard)
DC loop resistance (typ. FutureCom D values)
Max. delay (typ. FutureCom D values)
Corning Cable Systems
40 V
18 V
, 0.02 µs
Further
Information
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
FutureCom 10TEN
FutureCom F
Introduction
FutureCom™ D Certificates
Corning Cable Systems
85
FutureCom™ D Cat. 5 Cable
SF/UTP 300/24 FRNC or PVC
Braided shield
Halogen-free jacket,
flame retardant or PVC
Twisted pair
Foil shielding
4 shielded pairs
PE foam-skin insulation
Copper conductor
AWG 24
Application
The FutureCom SF/UTP 300/24 cable is designed for applications of up to 300 MHz and its transmission characteristics
exceed Category 5 (2002) and Category 5e (TIA/EIA-568-A-5)
specifications.
FutureCom cables are low-skew products, i.e. the skew
between the individual pairs is very low. This is increasingly
required for Gigabit-Ethernet. The cable has a streamlined
construction and low weight.
The four stranded pairs are sheathed with a foil shield
(F/UTP) and, additionally, with a braided shield (SF/UTP),
which guarantee outstanding shielding characteristics. The
cable satisfies the standard for Class B interference radiation
Color Coding
Pair 1
Pair 2
Pair 3
Pair 4
(EN 55022), as well as immunity (EN 55024), which enables
the realization of CE-compatible networks.
white with blue rings/blue
white with orange rings/orange
white with green rings/green
white with brown rings/brown
Features
SF/UTP 300/24 cable, specified up to 300 MHz
Outstanding electrical characteristics
Full braid copper shield
Streamlined design
Lightweight
Low skew between the pairs
Halogen-free (LSZH) jacket
Flame retardant according to IEC 60332-3, Category C
PVC jacket, flame retardant, according to IEC 60332-1,
Category B
FRNC is non-corrosive according to IEC 60754-2
86
Corning Cable Systems
damp rooms
Unbalance to ground dB/BZL = 100 m
Min. bending radius
>_ 35 mm (for 2 x
installation
(4x2...) over flat side)
Unbalance to ground dB/BZL = 100 m
Propagation velocity
(4x2...) over flat side)
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
>_ 50 mm (for 2 x
Electrical Characteristics (at 20°C)
1
Frequency in MHz
10
16
50.3
47.2
Attenuation in dB/100m *
2.1
6.3
Typical values in dB at 100m
77.0
62.0
Typical values dB/100m
2.0
NEXT in dB at 100 m*
65.3
PSNEXT in dB at 100 m *
62.3
Typical values in dB at 100m
75.0
ELFEXT in dB at 100 m *
63.8
Typical values in dB at 100m
72.0
PSELFEXT in dB at 100 m *
60.8
Typical values in dB at 100m
70.0
ACR in dB
75.0
5.6
47.3
60.0
43.8
60.0
40.8
58.0
56.4
20
>20 dB at 100 MHz
0.74 x c
4.5 ns/m
Delay skew
AWG 24
Copper conductor
>40 dB at 1 MHz
7 ns/100 m
31.25
62.5
100
8.0
9.0
11.4
16.5
21.3
59.0
57.0
54.0
50.0
46.0
7.2
44.2
57.0
39.7
54.0
36.7
52.0
51.8
8.0
45.8
42.8
55.0
37.8
52.0
34.8
50.0
49.0
10.1
42.9
39.9
52.0
33.9
48.0
30.9
46.0
43.9
14.4
38.4
35.4
48.0
27.9
40.0
24.9
38.0
35.6
18.2
35.3
32.3
44.0
23.8
34.0
20.8
32.0
27.8
250
29.5
–
38.5
–
36.5
–
22.1
–
20.1
–
9.0
* Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms with EN 50288-2-1)
Ordering Information
Type designation
Category
No. of
Pairs
SF/UTP 300/24 4P
5e (FRNC)
4
SF/UTP 300/24 4P
SF/UTP 300/24 8P
SF/UTP 300/24 4P
SF/UTP 300/24 4P
SF/UTP 300/24 8P
5e (FRNC)
5e (FRNC)
5e (PVC)
5e (PVC)
5e (PVC)
4
8
4
4
8
Max.
Outer [ Weight Length
Fire Load Halogen- Tensile
(kg/km) (m)
Order Number
Strength(N) (mm)
(MJ/m) free
0.46
FutureCom D
-20 to +60°C
Min. bending radius during
at 10 MHz
Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz
0 to +50°C
for one-time bending
<10 m V/m
300
32.2
–
35.0
–
33.0
–
17.0
–
15.0
–
2.8
0.46
Yes
82
6.1
50
1000
CCXDEF-C0047-C001-L7
0.41
No
82
5.8
45
1000
CCXDLF-C0047-C001-L7
0.96
0.41
0.94
Yes
Yes
No
No
82
164
82
164
6.1
50
6.2x13.5 100
5.8
45
6.2x13.5 97
* X1 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.
Corning Cable Systems
305
1000
305
1000
FutureCom F
Dry and
Operating temperature
100 V +/– 15%
Surface transfer impedance
FutureCom 10TEN
Impedance Zo at 1 - 100 MHz
flame retardant
Temperature range (installation)
125 V +/– 20%
FutureCom E
Halogen-free,
Area/range of application
>5000 MV x km
Impedance Zo at 0.064 MHz
FutureCom UD FutureCom UE
Foam-skin
Hardware
Sheath material
1%
Insulation resistance
CCXDEF-C0047-C001-X1*
CCXDEF-C0087-C001-L7
CCXDLF-C0047-C001-X1*
CCXDLF-C0087-C001-L7
87
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Largest resistance margin
FRNC: Halogen-free
Industrial
Cable
PE Foam skin
Special
Cable
PVC:
Conductor insulation
Electrical Characteristics (at 20°C)
Further
Information
Mechanical Characteristics
Introduction
FutureCom™ D Cat. 5 Cable
SF/UTP 300/24 FRNC or PVC
FutureCom™ D Cat. 5 Cable
SF/UTP 300/24 FRNC, 16P
Halogen-free
external jacket,
flame retardant
Foil
Halogen-free jacket,
flame retardant
Braided shield
Foil shielding
Metal-free
central element
Twisted pair
4 shielded pairs
Foam-skin PE
insulation
Copper conductor
AWG 24
Application
The FutureCom™ SF/UTP 300/24 16P cable is specified for
applications up to 300 MHz and its transmission
characteristics exeed Category 5 (2002) and Category 5e
(TIA/EIA 568-A-5).
FutureCom cables are low-skew products, i.e. the skew
between the individual pairs is very low. This is increasingly
required for Gigabit-Ethernet.
The four stranded pairs are foil shielded (F/UTP) additionally
with a braided shield (SF/UTP), which guarantees outstand-
ing shielding characteristics. The cable satisfies the standard
for Class B interference radiation (EN 55022), as well as immunity (EN 55024), which enables the realization of CEcompatible networks. The Quattro configuration with a
shared external sheath for the FutureCom SF/UTP 300/24
16P cable, allows increased mechanical load and enables
Color Coding
Pair 1
Pair 2
Pair 3
Pair 4
cost-optimized installation.
white with blue rings/blue
white with orange rings/orange
white with green rings/green
white with brown rings/brown
Features
SF/UTP 300/24 cable, specified up to 300 MHz
Outstanding electrical characteristics
Stranded pairs with foil shield and full braid shield. The
4 cable cores are twisted around a non-metallic central
element
Low skew between the pairs
Halogen-free (LSZH)
Flame retardant according to IEC 60332-3, Category C
Non-corrosive according to IEC 60754-2 (FRNC)
Low smoke according to IEC 61034
88
Corning Cable Systems
Min. bending radius
for one-time bending
Min. bending radius during
0 to +50°C
at 10 MHz
Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz
-20 to +60°C
Unbalance to ground dB/BZL = 100 m
>_ 85 mm
Unbalance to ground dB/BZL = 100 m
Propagation velocity
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
AWG 24
Copper conductor
<10 m V/m
1
Frequency in MHz
10
16
50.3
47.2
Attenuation in dB/100m *
2.1
6.3
Typical values in dB at 100m
77.0
62.0
Typical values dB/100m
2.0
NEXT in dB at 100 m*
65.3
PSNEXT in dB at 100 m *
62.3
Typical values in dB at 100m
75.0
ELFEXT in dB at 100 m *
63.8
Typical values in dB at 100m
72.0
PSELFEXT in dB at 100 m *
60.8
Typical values in dB at 100m
70.0
ACR in dB
75.0
5.6
47.3
60.0
43.8
60.0
40.8
58.0
56.4
20
>20 dB at 100 MHz
0.74 x c
4.5 ns/m
Delay skew
Electrical Characteristics (at 20°C)
>40 dB at 1 MHz
7 ns/100 m
31.25
62.5
100
8.0
9.0
11.4
16.5
21.3
59.0
57.0
54.0
50.0
46.0
7.2
44.2
57.0
39.7
54.0
36.7
52.0
51.8
8.0
45.8
42.8
55.0
37.8
52.0
34.8
50.0
49.0
10.1
42.9
39.9
52.0
33.9
48.0
30.9
46.0
43.9
14.4
38.4
35.4
48.0
27.9
40.0
24.9
38.0
35.6
18.2
35.3
32.3
44.0
23.8
34.0
20.8
32.0
27.8
250
29.5
–
38.5
–
36.5
–
22.1
–
20.1
–
9.0
* Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms with EN 50288-2-1)
300
32.2
–
35.0
–
33.0
–
17.0
–
15.0
–
2.8
SF/UTP 300/24 16P
Industrial
Cable
Ordering Information
Type designation
Max.
Outer [ Weight Length
Fire Load Halogen- Tensile
Category No. of Pairs (MJ/m) free
Strength(N) (mm) (kg/km) (m)
Order Number
5e
16
4.04
Yes
328
16.5
Corning Cable Systems
280
1000
FutureCom F
damp rooms
>_ 120 mm
installation
100 V +/– 15%
Surface transfer impedance
FutureCom 10TEN
Operating temperature
Impedance Zo at 1 - 100 MHz
Dry and
FutureCom D
Temperature range (installation)
125 V +/– 20%
FutureCom E
flame retardant
Area/range of application
>5000 MV x km
Impedance Zo at 0.064 MHz
FutureCom UD FutureCom UE
Halogen-free,
Outer jacket
1%
Insulation resistance
Hardware
Largest resistance margin
Foam-skin material
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Halogen-free
CCXDEF-C0167-C001-L7
89
Special
Cable
Conductor insulation
Electrical Characteristics (at 20°C)
Further
Information
Mechanical Characteristics
Introduction
FutureCom™ D Cat. 5 Cable
SF/UTP 300/24 FRNC, 16P
FutureCom™ D Cat. 5 Cable
F/UTP 300/24 FRNC or PVC
Foil shielding
PVC or
halogen-free jacket,
flame retardant
Twisted pair
Foil shielding
Additional wire
PE foam-skin insulation
Copper conductor
AWG 24
4 shielded pairs
Color Coding
white with blue rings/blue
Pair 4
white with orange rings/orange
Pair 3
The FutureCom™ F/UTP 300/24 Cable is designed for applications of up to 300 MHz and its transmission characteristics
exceed Category 5 (2002) and Category 5e (TIA/EIA-568-A-5)
specifications.
FutureCom cables are low-skew products, i.e. the skew be-
tween the individual pairs are very low. This is increasingly
required for Gigabit-Ethernet. The cable has a streamlined
construction and low weight.
The four stranded pairs are foil shielded (F/UTP). The cable
satisfies the standards for Class B interference radiation
(EN 55022), as well as immunitiy (EN 55024), which enables
the realization of CE-compatible networks.
Pair 1
Pair 2
Application
white with orange rings/orange
white with orange rings/orange
Features
F/UTP 300/24 cable, specified up to 300 MHz
Outstanding electrical characteristics
Full shielding with 2 foils and additional copper wire
Streamlined design
Lightweight
Low skew between the pairs
Halogen-free (LSZH) jacket
Flame retardant according to IEC 60332-3, Category C
PVC jacket, flame retardant according to IEC 60332-1,
Category B
Non-corrosive according to IEC 60754-2 (FRNC)
90
Corning Cable Systems
>_ 50 mm (for 2x
installation
(4x2...) over flat side)
Copper conductor
AWG 24
Electrical Characteristics (at 20°C)
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
10
16
50.3
47.3
Attenuation in dB/100m *
2.1
6.3
Typical values in dB at 100m
77.0
62.0
Typical values dB/100m
2.0
NEXT in dB at 100 m*
5.6
65.3
PSNEXT in dB at 100 m *
62.3
Typical values in dB at 100m
47.3
75.0
ELFEXT in dB at 100 m *
60.0
63.8
Typical values in dB at 100m
43.8
72.0
PSELFEXT in dB at 100 m *
60.0
60.8
Typical values in dB at 100m
40.8
70.0
ACR in dB
58.0
20
0.74 x c
4.5 ns/m
Delay skew
1
Frequency in MHz
>20 dB at 100 MHz
7 ns/100 m
31.25
62.5
100
8.0
9.0
11.4
16.5
21.3
59.0
57.0
54.0
50.0
46.0
7.2
44.2
57.0
39.7
54.0
36.7
52.0
8.0
45.8
42.8
55.0
37.8
52.0
34.8
50.0
10.1
42.9
39.9
52.0
33.9
48.0
30.9
46.0
14.4
38.4
35.4
48.0
27.9
40.0
24.9
38.0
18.2
35.3
32.3
44.0
23.8
34.0
20.8
32.0
250
29.5
–
38.5
–
36.5
–
22.1
–
20.1
–
75.0
56.4 51.8
49.0 43.9 35.6
27.8 9.0
* Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms to EN 50288-2-1)
Ordering Information
Type designation
Max.
Outer [ Weight Length
Fire Load Halogen- Tensile
Category No. of Pairs (MJ/m) free
Strength(N) (mm) (kg/km) (m)
Order Number
F/UTP 300/24 4P
5e
F/UTP 300/24 4P
F/UTP 300/24 8P
F/UTP 300/24 4P
F/UTP 300/24 4P
F/UTP 300/24 8P
300
32.2
–
35.0
–
33.0
–
17.0
–
15.0
–
2.8
5e
4
0.47
Yes
82
6.1
40
1000
CCXDEE-C0047-C001-L7
5e (PVC)
4
0.41
No
82
5.8
36
1000
CCXDLE-C0047-C001-L7
5e
5e (PVC)
5e (PVC)
4
8
4
8
0.47
0.94
0.41
0.94
Yes
Yes
No
No
82
164
82
164
6.1
40
6.2x13.5 82
5.8
36
6.2x13.5 79
*X1 cables are delivered in the Reelex box. All other cables are delivered on disposable reels.
Corning Cable Systems
305
1000
305
1000
FutureCom F
FutureCom 10TEN
Propagation velocity
FutureCom E
(4x2...) over flat side)
Min. bending radius during
Unbalance to ground dB/BZL = 100 m
FutureCom D
-20 to +60°C
>_ 35 mm (for 2x
>40 dB at 1 MHz
CCXDEE-C0047-C001-X1*
CCXDEE-C0087-C001-L7
CCXDLE-C0047-C001-X1*
CCXDLE-C0087-C001-L7
91
FutureCom UD FutureCom UE
Unbalance to ground dB/BZL = 100 m
0 to +50°C
for one-time bending
at 10 MHz
Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz
damp rooms
Min. bending radius
<10 m V/m
Hardware
Dry and
Operating temperature
100 V +/– 15%
Surface transfer impedance
flame retardant
Temperature range (in motion)
125 V +/– 20%
Impedance Zo at 1 - 100 MHz
Halogen-free,
Area/range of application
>5000 MV x km
Impedance Zo at 0.064 MHz
Foam-skin
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Outer jacket
1%
Insulation resistance
Industrial
Cable
Largest resistance margin
PE foam skin
FRNC: Halogen-free
Conductor insulation
Special
Cable
PVC:
Electrical Characteristics (at 20°C)
Further
Information
Mechanical Characteristics
Introduction
FutureCom™ D Cat. 5 Cable
F/UTP 300/24 FRNC or PVC
FutureCom™ D
Module Overview
Features
Fully compatible with all modular LANscape® systems
Wide range of installation options
Few individual components
High-level component density
Individual shielding
Halogen free
Fire class UL 94 V-0
Optimized construction for bandwidths up to 300 MHz
1500 connector cycles possible
Proven IDC technology for conductors with AWG 24 to
AWG 23
Module reusable several times
Individual Components of the S100e Module
S100e Basic Module
Features
Wire management using TIA/EIA 568 A/B coding
Shorter assembly times
Easy handling
Compatible with FutureCom™ F/UTP and SF/UTP cables
Wire Management
92
Corning Cable Systems
FutureCom™ D
S100e and S100eL Modules
Introduction
Features
Easy and quick to install, no special tools required
IDC connection (IDC = Insulation Displacement Contacts)
High-level component density
FutureCom F
Universal application in all modular LANscape® and
FutureCom™ components
Negligible disturbance effect from interference by means
FutureCom 10TEN
of the individual shielding of the modules
Utilization of additional cable strain relief
CAXCSN-00000-C001 is possible for increased pulling
CAXDSM-00100-C001
Description
S100e Module, 1xRJ45, shielded, Cat.5 (2002),
for wire diameter AWG 24 to AWG 23
(F/UTP and SF/UTP cables), incl. copper
FutureCom D
Order Number
Unit per
Delivery
1/1
FutureCom UD FutureCom UE
Ordering Information
FutureCom E
forces
conducting tape for installation in
LANscape patch panels,
S100e Double Module, 2xRJ45, shielded,
Cat.5 (2002), for wire diameter AWG 24
to AWG 23 (F/UTP and SF/UTP cable),
1/1
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
CAXDSM-00200-C001
Hardware
outlets and floor box solutions
incl. copper conducting tape for
installation in LANscape modular patch
panels, outlets and floor box solutions
for wire diameter AWG 23 to AWG 22
(PiMF cable), incl. copper conducting tape
1/1
Industrial
Cable
S100eL Module, 1xRJ45, shielded, Cat.5 (2002),
for installation in LANscape
Special
Cable
modular patch panels,
outlets and floor box solutions
A Class E link can be constructed in conjunction
with a S/FTP data cable and the corresponding
Further
Information
CAXGSM-00100-C001
patch cords.
Corning Cable Systems
93
FutureCom™ D
S100e Outlets and Patch Panel
Ordering Information
S100e Outlets
Order Number
Description
S100e Outlet, 2xRJ45,
Cat. 5/Cat. 5e, shielded,
Unit per
Delivery
inclined, incl. mounting
frame with grounding
flaps, 50x50 mm central
plate with designation
window, screw fixings,
CAXDSD-S0201-C001
CAXDSD-S0202-C001
S100e Patch Panel
Order Number
CAXDSV-02400-C001
copper conducting tape
(without face plate)
white, RAL 9010
1/1
pearl white, RAL 1013
1/1
Description
Unit per
Delivery
S100e Patch Panel 19“,
shielded,Cat.5/Cat.5e,
including 24 FutureCom
1/1
S100e modules and
copper conducting tape,
with integrated cable
strain relief, 1 U,
high-grade steel front
panel
Patch panel accessories please see page 156.
94
Corning Cable Systems
Order Number
CAXDSD-S0200-C001
Description
S100e Double Module Outlet,
2x RJ45, Cat. 5, inclined,
incl. mounting frame with
Unit per
Delivery
1/1
FutureCom F
Ordering Information
Introduction
FutureCom™ D
S100e Double Module Outlet
grounding flaps and
copper conducting tape
FutureCom 10TEN
(suitable for Rutenbeck-
compatible central plates
FutureCom D
FutureCom E
or face plates)
FutureCom UD FutureCom UE
Installation Option
S100e Double Module Outlet, 2x RJ45, Cat.5, inclined,
incl. mounting frame and copper conducting tape.
CAXDSD-S0200-C001
For example, mounted with a Busch-Jaeger central plate and
Industrial
Cable
Further
Information
Special
Cable
S100e Double Module Outlet with central plate
and face plate (Busch-Jaeger)
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
face plate
Corning Cable Systems
95
FutureCom™ D
S100eL Outlets and Patch Panel
Ordering Information
S100eL Outlets
Order Number
Description
S100eL Outlet,
2xRJ45, Cat. 5/Cat. 5e,
Unit per
Delivery
inclined, incl. mounting
frame with grounding
flaps, 50x50 mm central
plate with designation
window, screw fixings,
CAXGSD-S0201-C001
CAXGSD-S0202-C001
S100eL Patch Panel
Order Number
CAXGSV-02400-C001
copper conducting tape
(without face plate)
white, RAL 9010
1/1
Description
Unit per
Delivery
pearl white, RAL 1013
S100eL Patch Panel 19“,
shielded,Cat.5/Cat.5e,
including 24 FutureCom
1/1
1/1
S100eL modules and
copper conducting tape,
with integrated cable
strain relief, 1 U,
high-grade steel front
panel
Patch panel accessories please see page 156.
A Class E link can be constructed using S100eL patch panels and outlets, in conjunction
with a S/FTP data cable and the corresponding patch cords.
96
Corning Cable Systems
FutureCom™ D
Installation Options for Outlets
Option 1: “DELTAprofil” Combi-Frame, 80x80 mm, inclined,
Introduction
for three LANscape® modules, white, RAL 9010:
WAXWSE-S0301-C001
equipped with two S100e modules
FutureCom F
CAXDSM-00100-C001
with one MT-RJ module adapter frame
LAXLSN-00101-C001
ADP-MTRJ-CNKFL-CLS
and two blue SF/UTP flex/26 patch cords
CCADNF-D2002-A030-C0
Combi-Frame “DELTAprofil”
FutureCom D
Option 2: Surface mount outlet, inclined, including
mounting frame and central plate 50x 50 mm with
designation window, screw fixed, white, RAL 9010:
FutureCom UD FutureCom UE
CAXDSD-S0201-C001
equipped with one red labeling icon
WAXWSE-00007-C001
one gray labeling icon
WAXWSE-00003-C001
and one red SF/UTP flex/26 patch cord
CCADNF-D5002-A020-C0
combined with surface mount housing
Hardware
WAXWSE-00001-C003
and one “DELTAfläche” face plate
WAXWSE-00001-C002
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Double Surface Mount Outlet
FutureCom E
FutureCom 10TEN
with one MT-RJ adapter for multimode connector
Option 3: 3-Port frame set for the assembly of three LAN-
scape fiber optic or FutureCom copper modules, inclined, including mounting frame and one triple housing with designation window and dust protection flaps and 80x80 mm
face plate, white, RAL 9010:
Industrial
Cable
WAXWSE-V0301-C001
equipped with two gray labeling icons
WAXWSE-00003-C001
one yellow labeling icon
two S100e Modules
CAXDSM-00100-C001
and two gray SF/UTP flex/26 patch cords
Frame-Set for Three Modules, inclined
Corning Cable Systems
97
Further
Information
Special
Cable
WAXWSE-00005-C001
FutureCom™ D
Cat. 5 Patch Cords RJ45 to RJ45
Description
FutureCom D patch cords consist of Cat. 5 flex cable with
shielded RJ45 connectors at both ends. The flex cables have
four pairs and fully braided copper wire shielding. The patch
cords are tested according to IEC 60332-1, Category B. They
are available in various lengths and colors.
Features
SF/UTP flex cable, specified up to 300 MHz
Application-neutral due to using all four pairs
Minimum surface transfer impedance
(<10 mV/m at 10 MHz)
Outstanding transmission characteristics according to
Channel D (2002)
Cat. 5 / 5e
Ordering Information
CCAD
1
F -D
2
1
Select jacket material.
2
Select color
G = FRNC
N = PVC
1
2
3
4
5
6
98
=
=
=
=
=
=
gray
blue
yellow
green
red
black
002 - A
3
3
- C0
Select length.
005
010
015
020
030
040
050
060
075
080
100
150
=
=
=
=
=
=
=
=
=
=
=
=
0.5 meters
1 meter
1.5 meters
2 meters
3 meters
4 meters
5 meters
6 meters
7.5 meters
8 meters
10 meters
15 meters
Corning Cable Systems
FutureCom™ D
Plug and Play™ Solutions
Introduction
Application
The S100e Solution Packages are pre-terminated cable
sections with S100e modules at both ends. They are gener-
ally offered with FutureCom™ F/UTP 300/24 cables. Both
FutureCom F
modules are equipped with additional cable strain relief to
allow higher pulling force during installation (the pulling
force is restricted by the cable). They enable Plug and Play™
FutureCom 10TEN
installation and therefore significantly reduce installation
time. 100% factory testing reduces failures during installa-
CCADEE-B2044-A250-C0
CCADEE-B2044-A300-C0
CCADEE-B2044-A350-C0
CCADEE-B2044-A400-C0
CCADEE-B2044-A450-C0
CCADEE-B2044-A500-C0
CCADEE-B2044-A550-C0
CCADEE-B2044-A600-C0
CCADEE-B2044-A650-C0
CCADEE-B2044-A700-C0
CCADEE-B2044-A750-C0
CCADEE-B2044-A800-C0
CCADEE-B2044-A850-C0
CCADEE-B2044-A900-C0
and additional cable strain relief
S100e Solution Package F/UTP 300/24 - 10
10 m
S100e Solution Package F/UTP 300/24 - 15
15 m
S100e Solution Package F/UTP 300/24 - 30
30 m
S100e Solution Package F/UTP 300/24 - 20
S100 Solution Package F/UTP 300/24 - 25
e
S100e Solution Package F/UTP 300/24 - 35
S100e Solution Package F/UTP 300/24 - 40
S100e Solution Package F/UTP 300/24 - 45
S100 Solution Package F/UTP 300/24 - 50
e
20 m
25 m
35 m
40 m
45 m
50 m
S100e Solution Package F/UTP 300/24 - 55
55 m
S100 Solution Package F/UTP 300/24 - 70
70 m
S100 Solution Package F/UTP 300/24 - 85
85 m
S100e Solution Package F/UTP 300/24 - 60
S100e Solution Package F/UTP 300/24 - 65
e
S100e Solution Package F/UTP 300/24 - 75
S100e Solution Package F/UTP 300/24 - 80
e
S100e Solution Package F/UTP 300/24 - 90
60 m
65 m
75 m
80 m
90 m
Hardware
CCADEE-B2044-A200-C0
with two S100e modules
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
CCADEE-B2044-A150-C0
data cable, 4 pairs, FRNC jacket pre-terminated
Length
Industrial
Cable
CCADEE-B2044-A100-C0
Description
S100e Solution Package with F/UTP 300/24
Further
Information
Order Number
Special
Cable
Ordering Information
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
tion.
Corning Cable Systems
99
100
Corning Cable Systems
6.3. Cable
6.3.1. Cat. 6 U/UTP 250/23 Cable – FRNC or PVC
106
6.4.1. U250 Module Overview
108
6.4. Connecting Hardware
6.4.2. Keystone Module
109
6.4.3. U250fx Module
110
6.5. Hardware
6.5.1. U250 Outlets and Patch Panel
111
6.6. Patch Cords
112
6.7. Plug & Play™
113
114
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
6.7. Test Cable
FutureCom F
105
FutureCom 10TEN
6.2. Certificate
FutureCom E
102
FutureCom D
6.1. System Descriptions & Data
FutureCom UD FutureCom UE
FutureCom UE
Further
Information
6
Introduction
Table of contents
Corning Cable Systems
101
FutureCom™ UE System
FutureCom UE is a system solution developed by Corning for unshielded balanced cabling installations. It meets all require-
ments of the standards ISO/IEC 11801 (2002), EN 50173-1 (2003) for Class D and E links and for Category 5 and 6 components.
Face Plate
“DELTAprofil”,
80x80 mm
WAXWSE-00001-C001
U250 outlet, 2xRJ45,
Cat.6, inclined,
CAXVSD-S0201-C001
U/UTP UEflex/Cat.6,
blue,
2xRJ45 connectors,
4 pairs,
CCAVGB-D2002-A020-C0
FutureCom
U/UTP250/23 Cable
CCXVDE-B0042-C001-X1
19“ Patch Panel,
for up to
24 LANscape®
modules with
integrated cable strain
relief, 1 U,
front panel of
high-grade steel
WAXWSV-02400-C001
U250 module,
1xRJ45, unshielded,
Cat. 6
CAXVSM-00100-C001
Class E channel performance is achieved using high quality
Category 6 connecting hardware, Category 6 cables and the
corresponding patch cords.
On the basis of configuration with RJ45 connectors and RJ45
modules, the cabling is application neutral and hence
universally usable.
102
A FutureCom UE cabling system built in compliance with
the standards is therefore highly suitable for all known,
standardized voice and data transmission methods. This applies for example to analog voice transmission, ISDN, Token
Ring, Ethernet (10Base-T), Fast Ethernet (100Base-TX) and Gi-
gabit Ethernet (1000Base-T).
The performance of the FutureCom UE cabling system has
been certified by an independent test body (see certificate).
Corning Cable Systems
ACR in dB (typ. FutureCom UE values)
Min. ELFEXT in dB *
ELFEXT in dB (typ. FutureCom UE values)
Min. return loss in dB *
Return loss in dB (typ. FutureCom UE values)
* According to ISO/IEC 11801 (2002).
8.3
15.2
19.6
25.2
4.0
6.6
9.3
78.0
62.0
57.0
65.0
61.0
76.2
63.3
73.0
19.0
21.0
5.8
56.6
50.0
56.2
43.3
53.0
19.0
21.0
51.6
42.3
48.7
37.2
47.0
17.5
20.0
16.9
43.4
48.0
26.5
32.8
27.3
37.0
14.0
21.7
39.9
45.0
18.2
25.4
23.3
20.0
33.0
12.0
18.0
200
250
27.6
31.7
36.0
42.0
39.0
37.0
36.7
9.0
16.8
19.4
29.0
10.1
17.0
28.6
32.2
34.8
33.1
3.0
-2.8
10.4
4.8
17.3
15.3
27.0
25.0
9.0
8.0
16.0
15.0
The stated system data apply only when original FutureCom UE products are used. Derived values such as PSACR, PSNEXT,
PSELFEXT meet the specified standard values but are omitted for clarity of presentation.
Attenuation and
Near-end Crosstalk (NEXT)
NEXT in dB
(typ. FutureCom UE values)
min. NEXT in dB
According to standard
max. Attenuation in dB
According to standard
Attenuation in dB
(typ. FutureCom UE values)
Further
Information
Special
Cable
Industrial
Cable
in MHz
MHz
Frequency in
Frequency
FutureCom F
Min. ACR in dB *
155.5
FutureCom 10TEN
NEXT in dB (typ. FutureCom UE values)
100
FutureCom E
Min. NEXT in dB *
62.5
FutureCom D
1.8
20
FutureCom UD FutureCom UE
Attenuation in dB (typ. FutureCom™ UE values)
Max. attenuation in dB *
10
Hardware
1
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Frequency in MHz
Introduction
FutureCom™ UE System Data
for Channel Class E (2002)
Corning Cable Systems
103
FutureCom™ UE System Data
for Channel Class E (2002)
Far-end Crosstalk
(ELFEXT)
ELFEXT in dB
(typ. FutureCom™ UE
values)
Min. ELFEXT in dB
According to standard
Frequency in MHz
Return loss
Return loss in dB
(typ. FutureCom UE values)
min. Return loss in dB
According to standard
Frequency in MHz
Test Setup
FutureCom UE patch cord UEflex/Cat.6, 2 x RJ45, 3m
U250 Outlet, 2xRJ45
90 m FutureCom U/UTP250/23
U250 Patch Panel 19“
FutureCom UE patch cord UEflex/Cat.6, 2 x RJ45, 3m
104
Nominal intrinsic impedance
100 V
Max. DC loop resistance (according to standard) 40 V
DC loop resistance (typ. FutureCom UE values)
Corning Cable Systems
18 V
Further
Information
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
FutureCom 10TEN
FutureCom F
Introduction
FutureCom™ UE Certificate
Corning Cable Systems
105
FutureCom™ UE Cat. 6 Cables
U/UTP 250/23 FRNC or PVC
Jacket
FRNC or PVC
Central cross
member
Twisted pair
Copper conductor
AWG 23
Foam skin PE
insulation
Application
The FutureCom™ U/UTP 250/23 cable is designed for appli-
cations up to 250 MHz and provides transmission performance exceeding Category 6 specifications.
FutureCom cables are low skew products, i.e. the skew
between the individual pairs is very low. This is increasingly
being requested for Gigabit Ethernet. Additional features
are the slim design and low weight of the cables.
Features
U/UTP 250/23 cable, specified up to 250 MHz
Excellent electrical characteristics
Mechanical Characteristics
Outer jacket
FRNC Version:
PVC Version:
Area/range of application
Temperature range (installation)
Operating temperature
Min. bending radius
for one time bending
Min. bending radius during
installation
Copper conductor
106
Central cross member reduces risk of crushing
or kinking
Zero halogen,
flame retardant
PVC,
flame retardant
Dry and
damp rooms
0 to +50°C
-20 to +60°C
26 mm
52 mm
Central cross member can be cut off easily
for installation of connecting hardware
Low skew between the pairs
Low weight
Flame retardant to IEC 60332-1, Category B
Special Features of FRNC Version
Zero halogen version (ZH)
Non corrosive to IEC 60754-2 (NC)
Low smoke to IEC 61034 (LS)
AWG 23
Corning Cable Systems
FutureCom™ UE Cat. 6 Cables
U/UTP 250/23 FRNC or PVC
Introduction
Electrical Characteristics (at 20°C)
56 nF/km
70 V/ km
100 V +/ – 15 %
0.68 x c
FutureCom 10TEN
5.36 ns/m
FutureCom E
30 ns/100 m
Electrical Characteristics (at 20°C)
Frequency in MHz
1
10
16
20
31.25
62.5
100
250
66.0
59.3
56.2
54.8
51.9
47.4
44.3
38.3
Attenuation in dB/100m *
2.1
Typical values in dB at 100m
74.3
Typical values dB/100m
2.0
Next in dB at 100 m *
PSNEXT in dB at 100 m *
64.0
Typical values in dB at 100m
72.3
ELFEXT in dB at 100 m *
66.0
Typical values in dB at 100m
75.3
PSELFEXT in dB at 100 m *
64.0
Typical values in dB at 100m
72.3
ACR in dB
72.3
6.0
6.0
59.3
57.3
57.3
50.0
55.3
47.0
52.3
53.3
7.6
8.5
7.6
8.5
56.3
54.8
54.2
52.8
54.3
52.8
45.9
44.0
51.2
49.3
43.0
41.0
48.2
46.3
48.7
46.3
* Standard: Requirements on 100 m installed Category 6 cable (conforms with EN 50288-6-1)
10.7
10.6
51.9
49.9
49.9
40.1
45.4
37.1
42.4
41.2
15.5
15.3
47.4
45.4
45.4
34.1
39.4
31.1
36.4
32.1
19.9
19.6
44.3
42.3
42.3
30.0
35.3
27.0
32.3
24.7
33.0
32.3
38.3
36.3
36.3
22.0
27.3
19.0
24.3
6.0
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Delay skew
Ordering Information
Type designation
Category
U/UTP 250/23 4P
6
U/UTP 250/23 4P
U/UTP 250/23 4P
U/UTP 250/23 4P
6
6
6
Max.
Outer [ Weight Length
No. of Fire Load Halogen- Tensile
(kg/km) (m)
Order Number
Pairs (MJ/m) free
Strength(N) (mm)
4
0.56
Yes
100
6.0
42
305
CCXVDE-B0042-C001-X1
4
0.52
No
100
5.8
39
1000
CCXVKE-B0042-C002-L7
4
4
0.56
0.52
Yes
No
100
100
6.0
5.8
42
39
305
CCXVDE-B0042-C001-L7
CCXVKE-B0042-C002-X1*
Further
Information
*X1 cables are delivered in the Reelex box. All other cables are delivered on disposable reels.
1000
FutureCom D
at >10 MHz (NVP x C)
Propagation delay >_ 10 MHz
FutureCom UD FutureCom UE
Propagation velocity
FutureCom F
45 dB
Coupling attenuation at 30 MHz
Hardware
Characteristic impedance
Industrial
Cable
DC resistance
Special
Cable
Mutual Capacity
Corning Cable Systems
107
FutureCom™ UE
Module Overview
Features
Paired installation (no untwisting of pairs required)
Significantly faster installation times
Easy handling
Compatible with all FutureCom™ UE cables
Fully compatible with all modular LANscape® outlets,
patch panels and floor box solutions
Wide range of installation options
Few individual parts
High level component density
Halogen-free
Fire class UL94V-0
Optimized design with circuit board for bandwidths
of more than 300 MHz
Individual Components of the U250 Module
1500 mating cycles possible
Proven IDC termination for wires with AWG 24 to AWG 22
Module re-usable up to several times
Disassembled U250 Basic Module
Features
Wire management using TIA/EIA 568 A/B coding
Installation in pairs
(no untwisting of the pairs is necessary)
Rapid assembly times
Easy handling
Compatible with FutureCom™ Cat. 6 U/UTP cables
Wire Management
108
Corning Cable Systems
FutureCom™ UE
U250 Modules
Introduction
Features
Easy and quick to install, no special tools required
IDC connection (IDC = Insulation Displacement Contacts)
High-level component density
FutureCom F
Universal usage in all modular LANscape® and
FutureCom™ components
FutureCom 10TEN
Category 6 (2002), de-embedded
CAXVSM-00100-C001
Description
U250 Module, 1xRJ45, unshielded,
Cat. 6, for installation in LANscape
modular patch panels,
Unit per
Delivery
FutureCom E
Order Number
1/1
FutureCom D
Ordering Information
U250 Keystone Module,
1 x RJ45, unshielded,
Cat. 6. for installation
Hardware
Unit per
Delivery
1/1
in patch panels, outlets
and floor box solutions
Industrial
Cable
with keystone design
Special
Cable
CAXKSM-00100-C001
Description
Further
Information
Order Number
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
U250 Keystone Module
FutureCom UD FutureCom UE
outlets and floor box solutions
Corning Cable Systems
109
FutureCom™ UE
U250fx Module
Application
U250fx Modules are used for the assembly of consolidation
point cables with flexible wires
Features
Fully compatible with all modular LANscape® connecting
hardware
Wide range of installation options
Minimal number of parts
Proven IDC technology for AWG 24 and AWG 26 stranded
wires
Individual Parts of the U250fx Module
Module reusable several times
1500 mating cycles possible
Wire management with A/B printing (according to
TIA/EIA 568)
Paired installation (no untwisting of pairs required)
Easy handling
Category 6, de-embedded
Requirements for Consolidation Point Cables
Additional cable strain relief is neccessary for assembling
the flex wire modules
Assembled U250fx Module
(with additional cable strain relief)
CCS patch cords with RJ45 connectors are wired according
to TIA/EIA 568 B; when using other single-ended preterminated connecting cables, they should be wired
according to the RJ45 connector scheme
Installed solid wire cables should have a lower
attenuation specification than the flexible cable
Ordering Information
Order Number
CAXVSM-00100-C003
Description
U250fx Module, 1xRJ45, unshielded, Cat.6
especially designed for
consolidation point cables with
AWG 24/26 stranded wires,
incl. additional cable strain relief
for mounting in LANscape hardware
110
Corning Cable Systems
Units per
Delivery
1/1
FutureCom™ UE
U250 Outlets and Patch Panel
Order Number
Description
U250 Outlet, 2xRJ45,
unshielded, Cat. 6, inclined,
Unit per
Delivery
FutureCom F
U250 Outlets
Introduction
Ordering Information
FutureCom 10TEN
incl. mounting frame
with grounding flaps,
central plate 50x50 mm
U250 Patch Panel
Order Number
CAXVSV-02400-C001
white, RAL 9010
1/1
Description
Unit per
Delivery
U250 Patch Panel 19“,
unshielded, Cat. 6, incl.
24 FutureCom U250
1/1
FutureCom D
pearl white, RAL 1013
FutureCom UD FutureCom UE
CAXVSD-S0202-C001
(without face plate)
1/1
Hardware
CAXVSD-S0201-C001
screw-fixed,
FutureCom E
with designation window,
modules,
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
with integrated
cable strain relief,
1 U, high-grade steel
front panel
Further
Information
Special
Cable
Industrial
Cable
Patch panel accessories please see page 156.
Corning Cable Systems
111
FutureCom™ UE
Cat. 6 Patch Cords RJ45 to RJ45
Description
FutureCom UE patch cords consist of Category 6 flexible
cable, with unshielded RJ45 connectors at both ends. The
zero-halogen patch cords (LSZH) are non-corrosive
(according to IEC 60754-2), low smoke (according to IEC
61034) and flame retardant (according to IEC 60332-1,
Category B). They are available in different lengths and
colors.
Features
U/UTP flex cable, specified up to 250 MHz
Application-neutral due to using all four pairs
Outstanding transmission characteristics according to
Channel E (2002)
Cat. 6
Ordering Information
CCAVGB - D
1
Select color.
2
Select length.
1
002 - A
2
- C0
1 = gray
2 = blue
4 = green
010
020
030
050
060
100
112
=
=
=
=
=
=
1 meter
2 meters
3 meters
5 meters
6 meters
10 meters
Corning Cable Systems
FutureCom™ UE
Plug & Play™ Solutions
Introduction
Application
The U250 Solution Packages are pre-terminated cables with
U250 modules at both ends. They are generally offered with
FutureCom F
FutureCom™ U/UTP 250/23 cables. Both modules are
equipped with additional cable strain relief, to allow higher
pulling force during insertion (the pulling force is restricted
FutureCom 10TEN
by the cable only). They enable Plug and Play™ installation
CCAVDE-C1056-A250-C0
CCAVDE-C1056-A300-C0
CCAVDE-C1056-A350-C0
CCAVDE-C1056-A400-C0
CCAVDE-C1056-A450-C0
CCAVDE-C1056-A500-C0
CCAVDE-C1056-A550-C0
CCAVDE-C1056-A600-C0
CCAVDE-C1056-A650-C0
CCAVDE-C1056-A700-C0
CCAVDE-C1056-A750-C0
CCAVDE-C1056-A800-C0
CCAVDE-C1056-A850-C0
CCAVDE-C1056-A900-C0
U250 Solution Package U/UTP 250/23 - 10
10 m
U250 Solution Package U/UTP 250/23 - 15
15 m
U250 Solution Package U/UTP 250/23 - 30
30 m
U250 Solution Package U/UTP 250/23 - 20
U250 Solution Package U/UTP 250/23 - 25
U250 Solution Package U/UTP 250/23 - 35
U250 Solution Package U/UTP 250/23 - 40
U250 Solution Package U/UTP 250/23 - 45
U250 Solution Package U/UTP 250/23 - 50
U250 Solution Package U/UTP 250/23 - 55
U250 Solution Package U/UTP 250/23 - 60
U250 Solution Package U/UTP 250/23 - 65
U250 Solution Package U/UTP 250/23 - 70
U250 Solution Package U/UTP 250/23 - 75
U250 Solution Package U/UTP 250/23 - 80
U250 Solution Package U/UTP 250/23 - 85
U250 Solution Package U/UTP 250/23 - 90
20 m
25 m
35 m
40 m
45 m
50 m
55 m
60 m
65 m
70 m
75 m
80 m
85 m
90 m
Hardware
CCAVDE-C1056-A200-C0
with 2 U250 modules
and additional cable strain relief
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
CCAVDE-C1056-A150-C0
4 pairs, FRNC jacket pre-terminated
Length
Industrial
Cable
CCAVDE-C1056-A100-C0
Description
Solution Package, U/UTP 250/23 cable,
Further
Information
Order Number
Special
Cable
Ordering Information
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
and therefore significantly reduce installation time.
Corning Cable Systems
113
FutureCom™ UE Universal Test Cord
for Channel Testing
Application
This universal channel test cord is suitable for acceptance
tests of unshielded FutureCom™ UE systems in conjunction
with the universal test adapters from Fluke or other manufacurers.
One pair of these test cords is required for acceptance tests.
Ordering Information
Order Number
CCAVFG-D10M0-A030-C0
Description
Universal test cord for the acceptance tests
of the FutureCom UE System in conjuntion
with the universal test adapters from Fluke,
or other test device manufactures,
gray, 2xRJ45 connectors, 4 pairs, 3 m
114
Corning Cable Systems
Units per
Delivery
1/1
7.3. Cable
7.3.1. U/UTP 100/24 Cable FRNC or PVC
120
7.4.1. U100e Module Overview
122
7.4. Connecting Hardware
7.4.2. U100e Module
123
7.5. Hardware
7.5.1. U100e Outlets and Patch Panel
124
125
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
7.6. Patch Cords
FutureCom F
119
FutureCom 10TEN
7.2. Certificates
FutureCom E
116
FutureCom D
7.1. System Description & Data
FutureCom UD FutureCom UE
FutureCom UD
Further
Information
7
Introduction
Table of contents
Corning Cable Systems
115
FutureCom™ UD System
FutureCom UD (2002) is Corning’s Class D solution for unshielded balanced cabling. It meets all requirements of the
standard ISO/IEC 11801 (2002) and EN 50173-1 (2003) for Class D links and Category 5 components. In addition, the
FutureCom UD also satisfies Category 5e according to TIA/EIA 566-A-5.
Face Plate
“DELTAfläche”,
75x75 mm
WAXWSE-00001-C002
U100e outlet, 2xRJ45,
Cat.5, inclined,
CAXUSD-S0201-C001
U/UTP flex/26, gray,
2xRJ45 connectors,
4 pairs, for
10/100/1000 Base-T
CCAUGE-D1002-A030-C0
FutureCom
U/UTP100/24 Cable
CCXUEE-A0047-C001-L7
19“ Patch Panel,
for up to
24 LANscape®
modules with
integrated strain relief,
1 U, front panel of
high-grade steel
WAXWSV-02400-C001
U100e module,
1xRJ45, unschielded,
Cat. 5
CAXUSM-00100-C001
Class D (2002) channel performance is achieved through the
use of high quality Category 5 connecting hardware, cables
and patch cords.
On the basis of configuration with RJ45 connectors and the
RJ45 module, the cabling is application neutral and hence
universally usable.
116
A FutureCom UD cabling system built in compliance with
the standards is suitable for standardized voice and data
transmission methods. This applies for example to analog
voice transmission, ISDN, Token Ring, Ethernet (10-Base-T),
Fast Ethernet (100Base-TX) and Gigabit Ethernet (1000Base-T).
The performance of the FutureCom UD cabling system has
been certified by an independent test body (see certificate).
Corning Cable Systems
Min. ACR in dB *
ACR in dB (typ. FutureCom UD values)
Min. ELFEXT in dB *
ELFEXT in dB (typ. FutureCom UD values)
Min. return loss in dB *
Return loss in dB (typ. FutureCom UD values)
* According to ISO/IEC 11801 (2002).
57.8
62.6
57.0
67.0
17.0
19.0
62.5
6.3
8.0
9.4
11.5
16.0
4.5
7.0
55.0
51.0
50.6
46.1
51.1
45.0
57.0
17.0
21.0
44.0
37.0
44.7
37.0
49.0
17.0
22.0
9.2
40.6
46.5
31.4
38.5
32.9
45.0
17.0
22.0
10.3
39.0
45.0
28.7
35.6
31.0
43.0
17.0
22.0
12.8
35.7
40.0
22.9
30.5
27.0
39.0
15.1
20.1
100
18.5
24.0
35.5
32.0
21.9
30.6
27.1
12.1
3.1
19.5
10.1
21.1
17.0
33.0
29.0
12.1
10.1
17.0
15.0
The stated system data apply only when original FutureCom UD products are used. Derived values such as PSACR, PSNEXT,
PSELFEXT meet the specified standard values but are omitted for clarity of presentation.
Attenuation and
near-end crosstalk (NEXT)
NEXT in dB
(typ. FutureCom UD values)
min. NEXT in dB
According to standard
max. Attenuation in dB
According to standard
Attenuation in dB
(typ. FutureCom UD values)
Further
Information
Special
Cable
Industrial
Cable
in MHz
MHz
Frequency in
Frequency
in MHz
Frequency
FutureCom F
65.0
60.3
31.25
FutureCom 10TEN
NEXT in dB (typ. FutureCom UD values)
Min. NEXT in dB *
20
FutureCom E
3.9
4
Attenuation in dB (typ. FutureCom™ UD values)
16
FutureCom D
2.4
Max. attenuation in dB *
10
FutureCom UD FutureCom UE
4
Hardware
1
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Frequency in MHz
Introduction
FutureCom™ UD System Data
for Channel Class D (2002)
Corning Cable Systems
117
FutureCom™ UD System Data
Equal level far-end crosstalk
(ELFEXT)
ELFEXT in dB
typ. FutureCom™ UD values)
Min. ELFEXT in dB
According to standard
Frequency in MHz
Return loss in dB
Return loss in dB
(typ. FutureCom UD values)
min. Return loss in dB
According to standard
Frequency in MHz
Test Setup
FutureCom UD Patch Cord U/UTP flex/26, 2m
U100e
FutureCom Modules, 2 x RJ45
90 m FutureCom U/UTP100/24
U100e Patch Panel 19“
FutureCom UD Patch Cord U/UTP flex/26, 2m
118
Nominal impedance
Max. DC loop resistance (according to standard)
DC loop resistance (typ. FutureCom UD values)
Corning Cable Systems
100 V
40 V
18 V
Further
Information
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
FutureCom 10TEN
FutureCom F
Introduction
FutureCom™ UD Certificates
for Channel Class D (2002)
Corning Cable Systems
119
FutureCom™ UD Cat. 5e Cables
U/UTP 100/24 FRNC or PVC
Jacket
FRNC or PVC
Twisted pair
Copper conductor
AWG 24
Foam skin PE
insulation
Application
The FutureCom™ U/UTP 100/24 cable is designed for appli-
cations up to 100 MHz and provides transmission performance exceeding Category 5 and 5e specifications.
FutureCom cables are low skew products, i.e. the skew be-
tween the individual pairs is very low. This is increasingly being requested for Gigabit Ethernet. Additional features are
the slim design and low weight of the cables.
Features
U/UTP 100/24 cable, specified up to 100 MHz
Mechanical Characteristics
Conductor insulation
Outer jacket
Core and pairs are unshielded
Excellent electrical values
Slim design
PVC:
Flame retardant
Color Coding
Dry and
Pair 2
FRNC:
FRNC:
Operating temperature
Zero Halogen
foam-skin material
Zero Halogen
flame retardant
damp rooms
0 to +50°C
-20 to +60°C
Min. bending radius
>_ 25 mm (for 2x
installation
(4x2...) over flat side)
Min. bending radius during
120
IEC 60332-3, Category C
PE foam-skin material
Temperature range (installation)
Copper conductor
Halogen-free (LSZH) jacket, flame retardant to
PVC:
Area/range of application
for one-time bending
Low weight
PVC jacket, flame retardant to IEC 60332-1, Category B
Pair 1
Pair 3
Pair 4
(4x2...) over flat side)
>_ 40 mm (for 2x
AWG 24
Corning Cable Systems
white with blue rings/blue
white with orange rings/orange
white with green rings/green
white with brown rings/brown
FutureCom™ UD Cat. 5e Cables
U/UTP 100/24 FRNC or PVC
Max. resistance unbalance
3%
Impedance Zo at 1 – 100 MHz
100 V +/– 15%
Introduction
Electrical Characteristics (at 20°C)
>5000 V x km
Return loss: 4 – 10 MHz
>_ 20 + 5 log (f)
Longitudinal conversion loss dB/ref.
> 43 dB at 64 kHz
FutureCom 10TEN
FutureCom E
45 pF/m
0.74 x c
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
4.5ns/m
Electrical Characteristics (at 20°C)
Frequency in MHz
1
10
16
20
65.3
50.3
47.3
45.8
Attenuation in dB/100m *
2.1
Typical values in dB at 100m
77,4
Typical values dB/100m
1.9
NEXT in dB at 100 m *
PSNEXT in dB at 100 m *
62.3
Typical values in dB at 100m
74.0
ELFEXT in dB at 100 m *
63.8
Typical values in dB at 100m
68.0
PSELFEXT in dB at 100 m *
60.8
Typical values in dB at 100m
66.0
ACR in dB
74.1
6.3
5.9
65.5
47.3
60.0
43.8
49.0
40.8
47.0
56.1
8.0
7.4
62.2
44.2
56.0
39.7
45.0
36.7
43.0
50.6
62.5
42.9
38.4
11.4
59.7
57.7
8.4
42.8
54.0
37.8
42.0
34.8
40.0
47.6
* Standard: Requirements on 100 m installed Category 5e cable (conforms with EN 50288-3-1)
Ordering Information
31.25
9.0
10.5
39.9
51.0
33.9
40.0
30.9
38.0
42.5
21.3
49.6
46.6
15.1
35.4
47.0
27.9
33.0
24.9
31.0
33.9
Type designation
Max.
Outer [ Weight Length
Fire Load Halogen Tensile
(kg/km) (m)
Order Number
Strength(N) (mm)
(MJ/m) Free
U/UTP 100/24 8P
5e
1.22
U/UTP 100/24 4P
U/UTP 100/24 4P
U/UTP 100/24 8P
5e
4
5e
4
5e
5e
8
4
8
100
16.5
No. of
Category Pairs
U/UTP 100/24 4P
FutureCom D
7 ns/100 m
Delay skew
19.3
35.3
32.3
44.0
23.8
28.0
20.8
26.0
26.7
0.59
Yes
82
6.2
44
1000
CCXUEE-A0047-C001-L7
0.32
No
82
5.0
28
1000
CCXULE-A0047-C004-L7
0.32
0.76
Yes
No
No
164
82
164
6.0x13.0 88
5.0
28
5.0x12.0 56
*X1 cables are delivered in the Reelex box. All other cables are delivered on disposable reels.
Corning Cable Systems
1000
305
1000
CCXUEE-A0087-C001-L7
CCXULE-A0047-C004-X1*
CCXULE-A0087-C004-L7
121
FutureCom UD FutureCom UE
Propagation velocity
Hardware
Mutual capacity
>_ 25 dB - 7 log (f/20)
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
length = 1000m
>_ 25 dB
Industrial
Cable
Return loss: > 20 MHz
Special
Cable
Return loss: 10 – 20 MHz
FutureCom F
125 V +/– 20%
Impedance Zo at 0.064 MHz
Further
Information
Insulation resistance
FutureCom™ UD
Module Overview
Features
Fully compatible with all modular LANscape®
and FutureCom™ systems
Wide range of installation options
Few individual parts
High level component density
Optimized design for bandwidths of up to 100 MHz
1500 mating cycles possible
Proven IDC termination for wires with AWG 24
to AWG 23
Module re-usable several times
Halogen-free
Individual Parts of the U100e Module
Fire class UL 94V-0
U100e Basic Module
Features
Wire management using TIA/EIA 568 A/B coding
Shorter installation times
Easy handling
Compatible with FutureCom U/UTP Cat. 5 cables
Wire Management
122
Corning Cable Systems
FutureCom™ UD
U100e Module
Introduction
Features
Easy and quick to install, no special tools required
IDC connection (IDC = Insulation Displacement Contact)
High level component density
U100e module, 1xRJ45, unshielded,
Cat. 5 (2002) for installation in modular
LANscape patch panels,
FutureCom 10TEN
Units per
Delivery
1/1
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
outlets and floor box solutions
Special
Cable
CAXUSM-00100-C001
Description
Further
Information
Order Number
FutureCom E
Ordering Information
FutureCom F
Universally usable in all modular LANscape® components
Corning Cable Systems
123
FutureCom™ UD
U100e Outlets and Patch Panel
Ordering Information
U100e Outlets
Order Number
Description
U100e Outlet,
2xRJ45, Cat. 5/Cat. 5e,
Unit per
Delivery
unshielded, inclined,
incl. mounting frame
with grounding flaps,
50x50 mm central
plate with designation
CAXUSD-S0201-C001
CAXUSD-S0202-C001
U100e Patch Panel
Order Number
CAXUSV-02400-C001
window, screw fixings,
(without face plate)
white, RAL 9010
1/1
Description
Unit per
Delivery
pearl white, RAL 1013
U100e Patch Panel 19“,
unshielded, Cat. 5/Cat. 5e,
including 24 FutureCom
1/1
1/1
U100e modules,
with integrated cable
strain relief, 1 U,
high-grade steel front
panel
Patch panel accessories please see page 156.
124
Corning Cable Systems
FutureCom™ UD
Cat. 5 Patch Cords RJ45 to RJ45
Introduction
Description
FutureCom UD system patch cords consist of Category 5
flexible cables and are terminated with unshielded RJ45
connectors at both ends. The patch cords are flame
FutureCom F
retardant according to IEC 60332-1, Category B. They are
available in various lengths and colors.
FutureCom 10TEN
Features
U/UTP flex cable, specified up to 100 MHz
FutureCom E
Application-neutral due to using all four pairs
Outstanding transmission characteristics according to
Channel D (2002)
CCAU
1
E-D
1
Select cable type.
2
Select color.
3
Select length.
2
002 - A
3
FutureCom UD FutureCom UE
Ordering Information
FutureCom D
Category 5 (2002) or 5e according to TIA/EIA
- C0
=
=
=
=
=
=
=
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Industrial
Cable
005
010
020
030
040
050
060
gray
blue
yellow
green
red
black
0.5 meters
1 meter
2 meters
3 meters
4 meters
5 meters
6 meters
Special
Cable
=
=
=
=
=
=
Further
Information
1
2
3
4
5
6
Hardware
G = FRNC
N = PVC
Corning Cable Systems
125
126
Corning Cable Systems
8.1.2. Metal Outlets
138
8.2. Accessories for Floor Box Solutions
144
8.4. Consolidation Point Housing
157
8.3. Patch Panel and Patch Panel Accessories
152
8.5. Tools and Accessories
158
162
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
8.6. 1000 RT
FutureCom F
128
FutureCom 10TEN
8.1.1. Standard Outlets
FutureCom E
8.1. Outlets and Outlet Accessories
FutureCom D
Hardware
Further
Information
8
Introduction
Table of contents
Corning Cable Systems
127
Outlets and Outlet Accessories
Application
The LANscape® System offers outlet solutions for all instal-
lation options and mounting methods. There are various
styles available for surface, flush or raceway mounting.
Using various frame sets from the LANscape system, outlet
configurations with 1 to 6 ports can be individually com-
bined. The frame sets with a central plate size of 50 x 50 mm
can be combined with our “DELTAprofil” and “DELTAfläche”
face plates, as well as those of other manufacturers.
Ordering Information
Order Number
WAXWSM-00101-C001
WAXWSM-00108-C001
Description
Blank Cover, 1 position
for installation in modular
LANscape patch panels,
outlets and floor box solutions
white, RAL 9010
black, RAL 9005
Frame Sets for the Individual Configuration of Outlets
Order Number
Description
Frame Set, straight,
for 2 FutureCom™ modules,
Units per
Delivery
6/1
6/1
Units per
Delivery
including mounting frame
WAXWSE-G0201-C001
WAXWSE-G0202-C001
128
and 50x50 mm central plate
with designation window, screw fixing
white, RAL 9010
pearl white, RAL 1013
Corning Cable Systems
1/1
1/1
Outlets and Outlet Accessories
Order Number
Description
Frame Set, inclined, with grounding
flap, for 2 LANscape® modules,
Units per
Delivery
FutureCom F
Frame Sets for the Individual Configuration of Outlets
Introduction
Ordering Information
WAXWSE-S0202-C001
window, screw fixing
white, RAL 9010
pearl white, RAL 1013
1/1
1/1
FutureCom E
WAXWSE-S0201-C001
50x50 mm central plate with designation
FutureCom 10TEN
including mounting frame and
FutureCom D
Design Line - Special Color Options
Frame Set, inclined, with grounding
flap, for 2 LANscape® modules,
WAXWSE-S0203-C001
50x50 mm central plate with designation
window, screw fixing
gray, RAL 7035
FutureCom UD FutureCom UE
including mounting frame and
1/1
Frame Set, inclined, with grounding
Hardware
flap, for 2 LANscape® modules,
WAXWSE-S0208-C001
50x50 mm central plate with designation
window, screw fixing
black, RAL 9005
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
including mounting frame and
1/1
Projecting Frame Set for the Individual Configuration of Outlets
Description
Frame Set, inclined, projecting,
for 2 LANscape modules,
Units per
Delivery
Industrial
Cable
Order Number
Special
Cable
including mounting frame and
WAXWSE-V0201-C001
WAXWSE-V0202-C001
with designation window
and dust protection flaps
white, RAL 9010
pearl white, RAL 1013
Further
Information
50x50 mm central plate
1/1
1/1
Corning Cable Systems
129
Outlets and Outlet Accessories
Ordering Information
Frame Set, inclined, projecting, 3- or 6-Port Outlet
Order Number
Description
Frame Set, inclined, projecting,
for 3 LANscape® modules,
Units per
Delivery
including mounting frame
and triple housing
with designation window,
WAXWSE-V0301-C001
WAXWSE-V0302-C001
dust protection flaps
and face plate 80x80 mm
white, RAL 9010
1/1
pearl white, RAL 1013
1/1
Frame Set, inclined, projecting,
for 6 LANscape modules,
including mounting frame
and two triple housings
with designation window,
WAXWSE-V0601-C001
WAXWSE-V0602-C001
dust protection flaps and
face plate 151x80 mm
white, RAL 9010
1/1
pearl white, RAL 1013
1/1
Installation Option: 6-Port Frame Set for the mounting of 6
LANscape modules, inclined, including mounting frame and
two triple housings with designation window and dust protection flaps and face plate 151 x 80 mm, white, RAL 9010;
WAXWSE-V0601-C001
equipped with two S250 modules
CAXESM-00100-C001
two black labeling icons
WAXWSE-00008-C001
four blue labeling icons
WAXWSE-00004-C001
and two blue S/FTP/flex patch cables
Outlet for 6 modules, Inclined
130
CCAEGB-G2002-A030-C0
Corning Cable Systems
Outlets and Outlet Accessories
Introduction
Labeling Icons and Designation Labels
All frame sets with a 50x50 mm central plate as well as the
3- and 6-port frame sets offer the opportunity to code each
port with labeling icons. The icons indicate port applications
FutureCom F
and show a telephone or a computer (LAN operation). They
are available in six different colors. Furthermore, these
frame sets have a designation window with a clear cover, for
WAXWSE-00007-C001
WAXWSE-00008-C001
WAXWSE-00001-C009
Labeling Icon, computer/telephone,
yellow, RAL 1021
Labeling Icon, computer/telephone,
green, RAL 6029
Labeling Icon, computer/telephone,
red, RAL 3000
120/1
120/1
120/1
DIN A4 Title Strip Sheet,
10/1
with 150 designation labels
for LANscape® outlets, white,
FutureCom E
120/1
Labeling Icon, computer/telephone,
black, RAL 9005
FutureCom D
blue, RAL 5015
120/1
FutureCom UD FutureCom UE
WAXWSE-00006-C001
120/1
gray, RAL 7042
Hardware
WAXWSE-00005-C001
Labeling Icon, computer/telephone,
Labeling Icon, computer/telephone,
e.g. for labeling using a PC-printer
Industrial
Cable
WAXWSE-00004-C001
Units per
Delivery
Special
Cable
WAXWSE-00003-C001
Description
Further
Information
Order Number
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Ordering Information
FutureCom 10TEN
inserting a designation label.
Corning Cable Systems
131
Outlets and Outlet Accessories
Ordering Information
Face Plates for 50 x 50 mm Central Plates
Order Number
WAXWSE-00001-C001
WAXWSE-00002-C001
Description
“DELTAprofil” Face Plate, 80x80 mm,
for LANscape® outlets with
50x 50 mm central plate
white, RAL 9010
pearl white, RAL 1013
Units per
Delivery
1/1
1/1
“DELTAfläche” Face Plate, 75x75 mm,
WAXWSE-00001-C002
WAXWSE-00002-C002
for LANscape outlets with
50x 50 mm central plate
white, RAL 9010
pearl white, RAL 1013
Surface Mount Housing for “DELTAfläche” Outlets
Order Number
WAXWSE-00001-C003
WAXWSE-00002-C003
132
Description
“DELTAfläche” Surface Mount Housing,
for the individual configuration of
LANscape outlets, 75x75 mm
white, RAL 9010
pearl white, RAL 1013
Corning Cable Systems
1/1
1/1
Units per
Delivery
1/1
1/1
Outlets and Outlet Accessories
WAXWSE-S0301-C001
Units per
Delivery
white, RAL 9010
1/1
“DELTAprofil” Combi-Frame, 80x80 mm,
inclined, for 3 LANscape® modules
pearl white, RAL 1013
1/1
Installation Options
1/1
1/1
FutureCom UD FutureCom UE
pearl white, RAL 1013
Hardware
Option 1: “DELTAprofil” Combi-Frame, 80x80 mm,
inclined , white, RAL 9010;
WAXWSE-S0301-C001
equipped with two S250 Modules,
CAXESM-00100-C001
and one LC Duplex Module for multimode connectors
LAXLSM-00101-C007
Option 2: “DELTAfläche” Combi-Frame, 75x75 mm,
Industrial
Cable
“DELTAprofil”Combi-Frame
inclined , white, RAL 9010;
WAXWSE-S0301-C002
equipped with two S100e Modules,
CAXDSM-00100-C001
and one single MT-RJ Module for single-mode/multimode
“DELTAprofil” Combi-Frame
connectors
LAXLSM-00101-C004
Corning Cable Systems
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
white, RAL 9010
Special
Cable
WAXWSE-S0302-C002
inclined, for 3 LANscape modules
133
Further
Information
WAXWSE-S0301-C002
“DELTAfläche” Combi-Frame, 75x75 mm,
FutureCom D
FutureCom E
WAXWSE-S0302-C001
Description
FutureCom F
Order Number
FutureCom 10TEN
Combi-Frames
Introduction
Ordering Information
Outlets and Outlet Accessories
Brackets for Raceway Mounting
The following brackets can be used for the quick and simple
installation of outlets and frame sets in raceways.
They support the minimum bend radius requirements for
copper and fiber optic cables. In order to separate network
components from power systems, the brackets are supplied
with a removable half-shell partition, which can be
optionally inserted.
An additional advantage of the half-shell partition is the
protection of fiber optic connections against mechanical
damage during pulling of new cables. The brackets are
suitable for Tehalit and Ackermann raceways with T-groove
mounting.
Ordering Information
Order Number
WAXWSE-00001-C010
Description
Brackets for Raceway Mounting of outlets
and frame sets, T-groove mounting,
height 50 mm, with half-shell partition,
Units per
Delivery
1/1
white, RAL 9010
WAXWSE-00008-C002
Brackets for Raceway Mounting of outlets
and frame sets, T-groove mounting,
height 55 mm, with half-shell partition,
black, RAL 9005
134
Corning Cable Systems
1/1
Description
WAXWSE-00001-C008
Surface Mount Housing, 67x110 mm,
WAXWSE-V0201-C004
Combi-Frame, 67x110 mm,
for combi-frame (67x110 mm),
1/1
for installation of two
single LANscape® modules,
FutureCom E
FutureCom 10TEN
white, RAL 9010
Units per
Delivery
1/1
FutureCom D
Order Number
FutureCom F
Ordering Information
Introduction
Outlets and Outlet Accessories
inclined,
CAXCSE-G0201-C001
Combi-Frame, 45x45 mm,
with self-closing shutters for
the installation of 2 FutureCom™
FutureCom UD FutureCom UE
white, RAL 9010
1/1
Hardware
modules, straight,
Combi-Frame for VanGeel Columns,
45x45 mm, with self-closing shutters
for the installation of 2 FutureCom
Units per
Delivery
1/1
modules, straight,
white, RAL 9010
Special
Cable
CAXCSE-G0201-C002
Description
Further
Information
Order Number
Industrial
Cable
Combi-Frames for VanGeel Columns
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
white, RAL 9010
Corning Cable Systems
135
Outlets and Outlet Accessories
Ordering Information
Order Number
WAXWSE-00001-C004
Description
Surface Mount Housing, 87x87 mm,
including two screws for face plate
(87x87 mm),
Units per
Delivery
1/1
white, RAL 9010
WAXWSE-00001-C005
Face plate, 87x87 mm,
for one module housing,
including two metric screws
1/1
and two whitworth screws,
for face plate mounting in installation
outlets, white, RAL 9010
WAXWSE-00001-C006
Surface Mount Housing, 87x147 mm,
including two screws for face plate
(87x147 mm),
1/1
white, RAL 9010
WAXWSE-00001-C007
Face Plate, 87x147 mm,
for two module housings,
including two metric
screws and two whitworth screws,
for face plate mounting in installation
outlets, white, RAL 9010
136
Corning Cable Systems
1/1
Order Number
CAXCSE-V0201-C001
Description
Module Housings with
self-closing shutters, projecting,
inclined, for face plates
Units per
Delivery
1/1
FutureCom F
Ordering Information
Introduction
Outlets and Outlet Accessories
(147x87 mm and 87x87 mm)
FutureCom 10TEN
for the installation of 2 FutureCom™
Universal Module Housing,
projecting, inclined,
for face plates (147x87 mm and
1/1
FutureCom D
WAXWSE-V0201-C002
FutureCom E
modules, white, RAL 9010
87x87 mm) for the installation of
2 FutureCom™ modules,
FutureCom UD FutureCom UE
central partition provided,
white, RAL 9010
Surface Combi-Frame Set, 75x65 mm,
with self-closing shutters for the
installation of 2 FutureCom modules,
1/1
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
straight, white, RAL 9010
Further
Information
CAXCSE-U0201-C001
Corning Cable Systems
137
Metal Outlets for Industrial Applications
Application
The 2-port LANscape® industrial metal outlets with
integrated cable strain relief can be equipped with any
LANscape fiber optic or copper modules. The outlet is
suitable for harsh environmental conditions and can be
mounted on a surface, as well as in different configurations
(see page 139) on top hat rails (35 mm DIN rails).
Features
Integrated cable strain relief for two individual
cables (separate assembly possible)
Metal construction suitable for harsh environmental
conditions in industrial surroundings
Conductive housing for shielded FutureCom™ modules
Non-detachable designation label
Cable entry with brush strip provides dust protection
regardless of cable diameter
Non-detachable housing fastening screw
Horizontal and vertical top hat rail mounting
Excess length storage for fiber without exceeding
minimum bending radius
Retrofitting and re-equipping possible without complete
disassembly (2-piece housing)
Ordering Information
Order Number
WAXWSD-V0208-C001
Description
2-Port Metal Outlet
for Industrial Applications,
60x65x121 mm (HxWxD),
Unit per
Delivery
1/1
for the installation
of 2 LANscape modules,
inclined, projecting,
with designation window,
metal construction with
integrated cable strain relief,
anthracite, RAL 7016 *
* Other colors upon request
138
Corning Cable Systems
Metal Outlets for Industrial Applications
often have different distances between the top hat rails and the cabling conduits. In addition, there are two diagonally positioned drilled holes in the back of the outlet housing, so that the metal outlet can be mounted directly on the surface by removing the top hat rail clip.
Installation Option
2-port Metal Outlets for Industrial Applications, 60 x 65 x 121 mm (HxWxD), for the installation of two LANscape® modules,
inclined, with designation window, metal construction with integrated cable strain relief, anthracite, RAL 7016;
WAXWSD-V0208-C001
equipped with one S1200 Module,
Cat. 7
CAXFSM-00100-C001
in one S1200 Module Adapter
CAXFSN-00110-C001
Assembled with S/STP1200
FutureCom™ cable
CCXFCB-L0047-C001-L7
and with one MT-RJ Module
LAXLSM-00101-C004
and one MT-RJ UniCam® Connector
92-051-97-P-E
assembled with protected
MiniZip FO industrial cable
Special
Cable
J-VH(2ZN)H 2X1G50/125
Further
Information
(Left side) Closed metal outlets
(Right side) Basic housing with mounted copper and fiber optic cables
Corning Cable Systems
FutureCom D
The top hat rail clips can be assembled in four different positions, since distributor cabinets (e.g. robot or machine controls)
FutureCom UD FutureCom UE
Vertical top hat rail:
Middle top hat rail clip,
rotated 90°
Hardware
Horizontal top hat rail:
Lower top hat rail clip
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Horizontal top hat rail:
Middle top hat rail clip
Industrial
Cable
Horizontal top hat rail:
Upper top hat rail clip
FutureCom E
FutureCom 10TEN
FutureCom F
Introduction
Mounting on a Top Hat Rail (35 mm DIN rails) / On a Surface
139
4-Port Metal Outlets for Industrial Applications
Application
The 4-port LANscape® industrial metal outlets with
integrated cable strain relief can be equipped with any
LANscape fiber optic or copper modules. The outlet is
suitable for harsh environmental conditions and can be
mounted on a surface, as well as on a top hat rail (35 mm
DIN rails).
Features
Integrated cable strain relief for 4 individual cables
(separate mounting is possible)
Metal construction suitable for harsh environmental
conditions in industrial surroundings
Conductive housing for shielded FutureCom™ modules
Non-detachable designation label
Cable diameter-independent and dust-protected cable
entry
Integrated grounding pin
Non-detachable housing fastening screw
Horizontal and vertical top hat rail mounting is possible
Splice holder for 12 crimp-splice connections including
excess length storage for FO pigtails and cables, can be
retrofitted at any time
Retrofitting and re-equipping without complete
disassembly due to the two-part housing
Ordering Information
Order Number
WAXWSD-V0408-C001
Description
4-Port Metal Outlet
for Industrial Applications,
79x101x121 mm (HxWxD),
Unit per
Delivery
1/1
for the installation of
max. 4 LANscape modules,
inclined, with designation
window, metal construction
with integrated cable strain
relief, integrated grounding
pin, easy retrofitting of the
optional splice tray,
WAXLSD-0000-C001,
anthracite, RAL 7016 *
* other colors upon request
140
Corning Cable Systems
4-Port Metal Outlets for Industrial Applications
Introduction
Installation Option
4-port Metal Outlet for Industrial Applications, 79 x 101 x 121 mm (HxWxD), for the
FutureCom F
installation of max. 4 LANscape® mo-
dules, inclined, with designation window,
metal construction with integrated cable
WAXWSD-V0408-C001
CAXFSM-00100-C001
one a S1200 module
CAXFSN-00110-C001
Closed metal outlet
Basic housing
with mounted copper cables
Basic housing with mounted copper and
FO cables incl. splice tray
Splice tray (rear side) with
mounted splice connections
one S250 module, Cat. 6
CAXESM-00100-C001
FutureCom UD FutureCom UE
and with one SC duplex module
LAXLSM-00201-C001
with dust protection flap for SC duplex
multimode connector, beige
LAXLOK-00013-C001
equipped with splice tray
WAXLSD-00000-C001
incl. two stored crimp-splice
.... mounted on a top hat rail
Ordering Information
Splice Tray for 4-Port Metal Outlets,
15x96x92 mm (HxWxD),
with splice organizer for
Units per
Delivery
1/1
12 crimp-splice connections,
separate excess length storage
which support the minimum
Special
Cable
WAXLSD-00000-C001
Description
bend radius requirements
for fiber optic pigtails and cables,
anthracite, RAL 7016 *
Further
Information
Order Number
Industrial
Cable
connections of two SC pigtails
* other colors upon request
Corning Cable Systems
Hardware
Cat.7
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
equipped with one S1200 module,
FutureCom D
anthracite, RAL 7016;
FutureCom E
FutureCom 10TEN
strain relief, integrated grounding pin,
141
4-Port Metal Outlets for Industrial Applications
with Security Features
Description
Features
The LANscape® metal outlet is constructed entirely from
metal and is intended for wall surface mounting or
mounting in false floors. It offers space for four LANscape®
fiber optic or copper modules. The outlet is especially
designed for security applications.
Metal construction suitable for harsh environmental
conditions
Cable strain relief for individual cables at cable entry in
the basic housing using cable ties
Connection protection and security against accidental or
unauthorized access
Fastening of the housing cover using a central screw,
which can be protected, e.g. using a security label
Excess length storage for fiber optic cable, maintaining
the minimum bending radius
Basic housing designed to be conductive
(important when using FutureCom™ copper modules)
Basic housing with mounted
copper and FO cable
Closed metal outlet
with mounted copper and
FO cables
Ordering Information
Order Number
WAXWSD-U0407-C001
Description
Metal Outlet, 4-Port
45x93x143.5 mm (HxWxD),
for the installation of 4
Standard fastening shape (60 mm hole spacing)
Horizontal and vertical top hat rail mounting
Unit per
Delivery
1/1
LANscape individual
modules, straight, metal
construction with
integrated strain relief,
patchcord protection
and excess length storage
for FO cables,
WAXWSD-U0408-C001
red, RAL 3000 *
Metal Outlet, 4-Port
45x93x143.5 mm (HxWxD),
for the installation of 4
1/1
LANscape individual
modules, straight, metal
construction with
integrated strain relief,
patchcord protection
and excess length storage
for FO cables,
anthracite, RAL 7016 *
* other colors upon request
142
Corning Cable Systems
Features
The LANscape® metal outlet is constructed entirely from
Metal construction, suitable for harsh environmental
metal and is intended for wall surface mounting, raceway
conditions
mounting or mounting in false floors. It offers space for
Cable strain relief for individual cables in the basic
housing using cable ties
FutureCom F
four four LANscape fiber optic or copper modules.
Fastening of the housing cover using a central screw
Excess length storage for FO cables of max. length
0.6-1.0 m, for maintaining the minimum bending radius
Basic housing designed to be conductive
(important when using copper modules)
Standard fastening shape (60 mm hole spacing)
FutureCom D
FutureCom E
Horizontal and vertical top hat rail mounting
WAXWSD-U0407-C002
Description
Metal Outlet, 4-Port
45x93x87 mm (HxWxD),
for the installation of 4
Unit per
Delivery
1/1
Hardware
Order Number
FutureCom UD FutureCom UE
Closed metal outlets
with mounted
copper cables
Ordering Information
LANscape individual
modules, straight,
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
metal construction with
integrated strain relief and
excess length storage
for FO cables,
red, RAL 3000 *
45x93x87 mm (HxWxD),
for the installation of 4
1/1
Industrial
Cable
Metal Outlet, 4-Port
LANscape individual
modules, straight,
Special
Cable
metal construction
with integrated strain
relief and excess length
storage for FO cables,
Further
Information
WAXWSD-U0401-C002
FutureCom 10TEN
Description
Introduction
4-Port Metal Outlets for Industrial Applications
white, RAL 9010 *
* Other colors upon request
Corning Cable Systems
143
Accessories for Floor Box Solutions
Applications
The LANscape® mounting panels for floor boxes are suitable
for all fiber optic and copper modules.
Description
The modular system provides floor box solutions up to nine
ports for floor boxes manufactured by Ackermann,
Kleinhuis, Electraplan, VanGeel, OBO Bettermann and
Vergokan.
The cable strain relief is fixable in three different positions.
Self-adhesive designation strips are available for all ports.
Splicing of pigtails is possible in the floor box in combination with the protection box and a special splice tray.
Features
Suitable for all LANscape fiber optic or copper modules
Mounting in the Ackermann GES4 Floor Box
Installation Option
Robust metal construction, black
No additional mounting inserts required
Integrated individual strain relief of each cable
(regardless of the diamter)
Strain relief mountable in various positions
No screws necessary
Integrated grounding pin
Designation windows
Up-gradeable with protection box for fiber optic cabling
Up-gradeable with special splice trays
Mounting panel for Ackermann floor boxes GES 2, GES 4,
GES 4/10, GESR 4, GES 6, GES 6/10, GESR 7/10 (outer
mounting position only) or GES 8/10;
WAXWSU-00600-C003
The two installation positions (3 modules each) are
equipped with:
three S250 modules
CAXESM-00100-C001
one SC duplex module
LAXLSM-00208-C001
and one blank cover
WAXWSM-00108-C001
144
Corning Cable Systems
Mounting Panels for Ackermann Floor Boxes
Order Number
WAXWSU-00600-C003
Description
Mounting Panel for Ackermann
Floor Boxes GES 2, GES 4, GES 4/10,
GESR 4, GES 6, GES 6/10, GESR 7/10
Units per
Delivery
1/1
FutureCom F
Ordering Information
Introduction
Accessories for Floor Box Solutions
FutureCom 10TEN
(outer mounting position only)
or GES 8/10, for the installation of
6 LANscape modules, with integrated
strain relief and six cable ties,
Mounting Panel for Ackerman
Floor Boxes GESR 7/10 (middle
mounting position only), GES 9
1/1
FutureCom D
WAXWSU-00900-C003
FutureCom E
designation window, metal, black
or GESR 9, for the installation of
FutureCom UD FutureCom UE
9 LANscape modules, with integrated
strain relief and nine cable ties,
Mounting Panel for VanGeel Floor Box
(IK-1 long), for the installation of
9 LANscape modules, with
Units per
Delivery
1/1
integrated cable strain relief
and nine cable ties,
Industrial
Cable
designation window, metal, black
Special
Cable
WAXWSU-00900-C005
Description
Further
Information
Order Number
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Mounting Panels for VanGeel Floor Boxes
Hardware
designation window, metal, black
Corning Cable Systems
145
Accessories for Floor Box Solutions
Ordering Information
Mounting Panels for Kleinhuis Floor Boxes
Order Number
WAXWSU-00900-C002
Description
Mounting Panel for Kleinhuis
Floor Box GR. II or GR. III
(outer mounting position
Units per
Delivery
1/1
only in the round box),
for the installation of 9 LANscape®
modules, with integrated cable
strain relief and nine cable ties,
designation window, metal, black
Mounting Panels for Electraplan Floor Boxes
Order Number
WAXWSU-00900-C004
Description
Mounting Panel for Electraplan
Floor Box KDR Q3 and KDR R3
(left, center, right), for the
Units per
Delivery
1/1
installation of 9 LANscape modules,
with integrated cable strain relief
and nine cable ties,
designation window, metal, black
Mounting Panels for Vergokan Floor Boxes
Order Number
WAXWSU-00900-C006
Description
Mounting Panel for Vergokan
Floor Box KDSVV (left, center, right),
for the installation of 9 LANscape
modules, with integrated cable
strain relief and nine cable ties,
designation window, metal, black
146
Corning Cable Systems
Units per
Delivery
1/1
Mounting Panels for OBO Bettermann Floor Boxes
Order Number
WAXWSU-00900-C007
Description
Mounting Panel for OBO Bettermann
Floor Boxes GE 12 R/5,GE 12R/10,
GE 12 RK/5,GE 12RK/10, (left, center,
Units per
Delivery
1/1
FutureCom F
Ordering Information
Introduction
Accessories for Floor Box Solutions
FutureCom 10TEN
right), for the installation of
9 LANscape® modules, with
integrated cable strain relief
and nine cable ties,
Order Number
WAXWSU-00000-C003
Description
Protection Box for Ackermann
Floor Boxes (GES 2, GES 4,
GES 4/10, GESR4, GES 6, GES 6/10,
FutureCom D
Units per
Delivery
FutureCom UD FutureCom UE
Protection Boxes for Mounting Panels
FutureCom E
designation window, metal, black
1/1
GESR 7/10 (only outer mounting
position) or GES 8/10, with integrated
Floor Boxes GESR 7/10 (only center
position), GES 9 or GESR 9, Kleinhuis
1/1
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Protection Box for Ackermann
Gr. II or Gr. III (only outer mounting
position in round boxes), Elektroplan
KDR Q3 or KDR R3 (left, center, right),
VanGeel (IK-1 long), Vergokan KDSVV
(left, center, right) and OBO Bettermann
Industrial
Cable
GE12 R1S, GE 12 R/10, GE 12 RK/5 or
GE 12 RK/10 (left, center, right),
with integrated cable management,
Special
Cable
metal, black
Further
Information
WAXWSU-00000-C004
Hardware
cable management, metal, black
Corning Cable Systems
147
Accessories for Floor Box Solutions
Ordering Information
Protection Boxes for Mounting Panels
Order Number
WAXLSU-00000-C005
Description
Splice Tray for Protection Box
WAXWSU-00000-C003
(Ackermann GES 2, GES 4, GES 4/10,
Units per
Delivery
1/1
GESR 4, GES 6, GES 6/10, GESR 7/10,
outer mounting position only, or
GES 8/10), with splice organizer for
the storage of 12 crimp-splice
protectors, metal, black
WAXLSU-00000-C006
Splice Tray for Protection Box
WAXWSU-00000-C004 for Ackermann
Floor Boxes GESR 7/10 (only center position),
1/1
GES 9 or GESR 9, Kleinhuis Gr. II or Gr. III
(only outer mounting position in round
boxes), Elektroplan KDR Q3 or KDR R3
(left, center, right), VanGeel (IK-1 long),
Vergokan KDSVV (left, center, right) and
OBO Bettermann GE12 R1S, GE 12 R/10,
GE 12 RK/5 or GE 12 RK/10 (left, center, right),
with splice organizer for the storage of
12 crimp-splice protectors, metal, black
Mounting Panels for Ackermann Floor Boxes
Features
Suitable for all LANscape fiber optic or copper modules
Metal construction, high-grade steel
No mounting insert required
Order Number
WAXWSU-00100-C001
Description
Mounting Panel for Ackermann
Floor Boxes GESR 2, for the
installation of one LANscape
module, with grounding flap,
metal, high-grade steel
148
Corning Cable Systems
Units per
Delivery
1/1
Accessories for Floor Box Solutions
Mounting Panel for Ackermann
Floor BoxGES 2,GES 4, GES 4/10,
GESR 4, GES 6, Ges6/10, GES7/10
Units per
Delivery
FutureCom F
WAXWSU-00600-C004
Description
1/1
(outside) or GES 8/10 for the
installation of 6 LANscape® modules,
Mounting Panel for Ackermann
Floor Box GESR 7/10 (center), GES 9,
or GESR 9, for the installation of
1/1
FutureCom D
WAXWSU-00900-C001
FutureCom E
high-grade steel
9 LANscape modules,
FutureCom UD FutureCom UE
high-grade steel
Hardware
Installation Option
Mounting panel for Ackermann floor box GESR 2
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
WAXWSU-00100-C001
equipped with one S1200 module
CAXFSM-00100-C001
in conjunction with an adapter frame
Industrial
Cable
CAXFSN-00110-C001
Further
Information
Mounting in the Ackermann Floor Box GESR 2
Special
Cable
Order Number
FutureCom 10TEN
Mounting Panels for Ackermann Floor Boxes
Introduction
Ordering Information
Corning Cable Systems
149
Accessories for Floor Box Solutions
Features
Suitable for all LANscape® modules in conjunction with
universal module housings (WAXWSE-V0201-C002)
Robust metal construction
No mounting insert required
Integrated cable strain relief
Rapid installation by snapping the module housings into
the mounting panel
No screws required
Ordering Information
Order Number
WAXWSU-00400-C001
Description
Mounting Panel for Ackermann
Floor Boxes GES 2, GES 4, GES 4/10,
GESR 4, GES 6, GES 6/10, GESR 7/10
Units per
Delivery
1/1
(only center position) or GES 8/10
for the installation of 2 LANscape
housings (WAXWSE-V0201-C002 or
CAXCSE-V0201-C001),
high-grade steel
WAXWSU-00600-C001
Mounting Panel for Ackermann
Floor Boxes GESR 7/10 (center),
GES 9, or GESR 9, for the installation
1/1
of 3 LANscape Housings
(WAXWSE-V0201-C002 or
CAXCSE-V0201-C001),
high-grade steel
WAXWSU-00600-C002
Mounting Panel for Kleinhuis
Floor Box GR.II and GR.III (outside
mounting position in round box),
for the installation of 3 LANscape
Housings (WAXWSE-V0201-C002
or CAXCSE-V0201-C001),
high-grade steel
150
Corning Cable Systems
1/1
Accessories for Floor Box Solutions
WAXWSU-00000-C001
Description
Blank Cover Panel for unused
mounting positions, suitable
for Ackermann and Kleinhuis
Delivery
FutureCom F
Order Number
1/1
FutureCom 10TEN
Blank Cover Panel
Introduction
Ordering Information
mounting panels (page 150),
FutureCom D
FutureCom E
metal, high-grade steel
Installation Options
FutureCom UD FutureCom UE
Mounting panel in the Kleinhuis floor box GR. III
WAXWSU-00600-C002
The three installation positions are configured as follows:
1. Blank Cover
WAXWSU-00000-C001
CAXCSE-V0201-C001
equipped with two S100eL modules
CAXGSM-00100-C001
and one green S/FTP flex/26 patch cord
CCAEGB-G4002-A030-C0
Mounting in the Kleinhuis Floor Box GR. III
3. Universal Housing
WAXWSE-V0201-C002
Industrial
Cable
equipped with one S100eL module
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
2. Module housings with self-closing shutters
CAXGSM-00100-C001
and one gray S/FTP flex/26 patch cord
CCAEGB-G1002-A020-C0
Special
Cable
and one MT-RJ fiber optic module
Further
Information
LAXLSM-00101-C004
Corning Cable Systems
151
Patch Panels and Patch Panel Accessories
Ordering Information
Order Number
WAXWSV-02400-C001
Description
19“ Patch Panel,
for max. 24 LANscape®
fiber optic or FutureCom™
Units per
Delivery
1/1
copper modules, with
integrated cable strain
relief, 1 U,
high-grade steel
WAXWSV-02400-C002
19“ Patch Panel,
for max. 24 LANscape
fiber optic or FutureCom
1/1
copper modules, 1 U,
high-grade steel
WAXWSV-01200-C001
10“ Patch Panel,
for max. 12 LANscape
fiber optic or FutureCom
1/1
copper modules, with
integrated cable strain
relief, 1 U,
high-grade steel
WAXWSV-04800-C001
19“ Patch Panel,
for max. 48 LANscape
fiber optic or FutureCom
1/1
copper modules, with
integrated cable strain
relief, 3 U,
high-grade steel
152
Corning Cable Systems
Ordering Information
Units per
Delivery
Description
19“ Blank Panel,
to fill unused areas
FutureCom F
Order Number
Introduction
Patch Panels and Patch Panel Accessories
WAXWSW-00000-C007
2U
1/1
19“ Cable Management
1/1
Panel, 1 U, high-grade steel
front panel with 5 black
FutureCom E
1/1
FutureCom D
WAXWSW-00000-C005
1U
FutureCom UD FutureCom UE
WAXWSW-00000-C004
or rack,
high-grade steel
FutureCom 10TEN
in the distribution cabinet
cable management
19“ Cable Feedthough
Panel, for feeding the
cables into the cabinet
1/1
interior or rack, incl. edge
grommeting, high-grade
Special
Cable
Industrial
Cable
steel front panel
Further
Information
WAXWSW-00000-C008
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
brackets
Corning Cable Systems
153
Patch Panels and Patch Panel Accessories
Ordering Information
Order Number
WAXWSV-02408-C001
Description
19“ Patch Panel,
for max. 24 LANscape®
fiber optic or FutureCom™
Units per
Delivery
1/1
copper modules, with
integrated cable strain
relief, 1 U,
black
WAXWSV-02408-C002
19“ Patch Panel,
for max. 24 LANscape
fiber optic or FutureCom
1/1
copper modules, 1 U,
black
154
Corning Cable Systems
Order Number
Description
19“ Blank Panel,
to fill unused areas
Units per
Delivery
FutureCom F
Ordering Information
Introduction
Patch Panels and Patch Panel Accessories
WAXWSW-00008-C007
2U
1/1
19“ Cable Management
1/1
Panel,1 U, black
front panel with 5 black
FutureCom E
1/1
FutureCom D
WAXWSW-00008-C005
1U
FutureCom UD FutureCom UE
WAXWSW-00008-C004
cabinet or rack,
black
FutureCom 10TEN
in the distribution
cable management
19“ Cable Feedthough
Panel, for feeding the
cables into the cabinet
1/1
interior or rack, incl. edge
grommeting, black
Special
Cable
Industrial
Cable
front panel
Further
Information
WAXWSW-00008-C008
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
brackets
Corning Cable Systems
155
Patch Panels and Patch Panel Accessories
Ordering Information
Designation Labels for Patch Panels
Order Number
Description
Delivery
WAXWSW-00000-C002
440 mm Designation Window,
1/1
WAXWSW-00000-C003
DIN A4 Designation Label Sheet,
1/1
Description
Units per
Delivery
Dust Protection Plug
Order Number
TKE:1304010
156
self-adhesive for LANscape®
patch panels
with 20 title strips
for LANscape patch panels, white
Dust Protection Plug for
RJ45 Modules, gray
Corning Cable Systems
1/100
Consolidation Point Housings for LANscape® Modules
Introduction
Features
Full metal housing for up to 12 LANscape® fiber optic
or copper modules
Conforms to standards ISO/IEC 11801 (2002) and
FutureCom F
EN 50173-1 (2003)
Ideally suited for a distribution or consolidation point
Suitable for ceiling, wall, false floor or desk mounting
FutureCom 10TEN
Individual strain relief for incoming and outgoing cables
Dust-proof feedthrough for incoming cables
Easy plug-in of consolidation point cables (dust protection and mechanical protection)
FutureCom E
Housing floor electrically conductive for optimal
shielding transition or grounding
Installation height of 60 mm
FutureCom D
Fastening of the housing top with non-detachable screws
Consolidation Point
Housing for max.
12 LANscape modules,
Units per
Delivery
1/1
with cable strain relief
for incoming data
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
cable, patch cord strain
relief and dust protection
flap for floor, wall and
ceiling mounting,
60 x 263 x 320 mm
Industrial
Cable
(HxWxD)
Special
Cable
WAXWSW-00008-C015
Description
Further
Information
Order Number
Hardware
Ordering Information
FutureCom UD FutureCom UE
Black sheet steel housing top, RAL 9005, white labeling
Corning Cable Systems
157
Tools and Accessories
Description
The installation of FutureCom™ modules is even easier and
quicker with special tools. These high-quality tools are
available together in a practical toolkit, as well as
individually. The use of parallel pliers to terminate the
IDC-contacts of the FutureCom F S1200 modules is strongly
recommended (see page 160).
Ordering Information
Order Number
CAXCSN-00000-C005
Description
Assembly Toolkit for FutureCom Modules
1
4
5
13
158
Units per
Delivery
1/1
2
6
7
8
3
9
14
Corning Cable Systems
10
11
12
15
Application
Assembly of additional cable strain relief for S100e, S100eL and S250 Modules
2. Module Tool
Assembly of the basic modules with wire management
for S10TEN, S100e, S100eL and S250 Modules
3. S1200 Installation Tool
Tool for stripping cable, trimming PiMF foil and preparing the pairs of S1200
5. Screwdriver for Cross Slotted Screws, Size 1
Universal
7. Electronics Edge-Cutter, 125 mm
8. Waterproof Pen, white
9. Waterproof Pen, black
10. Telephone Scissors, 130 mm
11. Open-Ended Wrench, size 8 x 10
12. Tape Measure, 1.4 m long
13. Copper Conducting Tape, 12.7 mm wide,
16.5 m
14. Steel Ruler, 300 mm long
Universal
Universal
Marking
Marking
Universal
Hexagon head bolts/nuts, size 8 x 10
Universal
Module installation (terminating braid shield)
Universal
Cutting cable sheath
15. “Jokari” Stripping Knife
Special
Cable
16.5 m
1/1
Industrial
Cable
Copper Conducting Tape, 12.7 mm wide,
Units per
Delivery
Further
Information
CAXCSN-00000-C004
Description
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Ordering Information
Hardware
Assembly of S1200/S250/S250fx/U250/U250fx/S100eL/S100e/U100e Modules
16. Installation Instructions
Order Number
FutureCom E
6. Edge-cutter
Universal
FutureCom D
4. Screwdriver for Slotted Screws, Size 4
modules or connectors
FutureCom F
1. Crimping Tool
FutureCom 10TEN
Description
FutureCom UD FutureCom UE
Assembly Toolkit Contents
Introduction
Tools and Accessories
Corning Cable Systems
159
Tools and Accessories
Ordering Information
Parallel Pliers for S1200 Module Assembly
Order Number
CAXCSN-00000-C008
S1200 Assembly Tool
CAXFSN-00000-C001
160
Description
Comfort Wide-Jawed Parallel Pliers,
for terminating IDC contacts on
FutureCom™ S1200 Modules
S1200 Assembly Tool, for S1200 modules
and S1200/4- or S1200/2 connectors
Corning Cable Systems
Units per
Delivery
1/1
1/1
Tools and Accessories
CAXCSN-00000-C007
Description
Assembly Tool,
for connecting
the basic modules
Units per
Delivery
FutureCom F
Order Number
1/1
FutureCom 10TEN
Assembly Tool for Modules
Introduction
Ordering Information
with the wire
management for
FutureCom™ S10TEN,
FutureCom E
S10TEN fx, S250, S250fx,
U250, U250fx, S100eL,
Crimping Pliers for die assembly
of the additional cable strain relief
for the FutureCom™ S10TEN,S10TEN fx,
Units per
Delivery
1/1
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
S250, S250fx, U250, U250fx, S100eL,
Industrial
Cable
S100e, U100e modules
Special
Cable
CAXCSN-00000-C002
Description
Further
Information
Order Number
Hardware
Crimping Pliers for Additional Strain Relief
FutureCom UD FutureCom UE
FutureCom D
S100e, U100e modules
Corning Cable Systems
161
IDC Terminal Strips 1000 RT
Description
Corning Cable Systems IDC terminal strips provide a reliable
Features
and effective wire connection for telecommunications and
data networks at very high density. Our strips can be mounted in 19“ panels or IDC blocks, for direct connectorization,
with punch down tool. The IDC terminal strips offer a very
high density with a height of only 13.8 mm including wire
guides. They are easy to install and maintain. Userfriendly
cable management supports longterm control over changing jumpering.
High density
User-friendly cable managment through wire guides
High felxibility due to adaptability of different wire
guides
Multiple access wire guiding of incoming wires
(e.g. system cable to be terminated on upper row of IDC
contacts) is possible from either rear or left or right hand
side.
Multiple access wire guiding of outgoing wires (to be
terminated on lower row of IDC contacts) is possible
from either left or right hand side
All combinations possible and available on request
Suitable for conductor size AWG 22-28
Ordering Information
IDC Disconnection Terminal Strips
Order Number
C39104-A123-A10
C39104-A123-A11
C39104-A123-A12
C39104-A123-A13
Description
Units per
Delivery
numbered, white
10 pairs
numbered, white
10 pairs
Cable side from the right,
jumper side from the left
numbered, white
numbered, white
IDC Switching Terminal Strips
C39104-A123-A40
numbered, blue
C39104-A123-A43
numbered, blue
C39104-A123-A41
C39104-A123-A42
162
numbered, blue
numbered, blue
10 pairs
10 pairs
10 pairs
10 pairs
10 pairs
10 pairs
Corning Cable Systems
IDC Terminal Strip 1000RT
19“ Rack
Ordering Information
Description
Units per
Delivery
C39393-A80-D53
Horizontal 19“ Rack (empty) for Series 1000RT IDC terminal strips,
1
* different sizes of mounting and full cablinet frames also available
Overvoltage / Overcurrent Terminal Strips Protection
S30264-D1006-S211
Overvoltage (3-point) 230 V + 20 %, with fail safe
Overvoltage / Overcurrent (5-Point), 230 V + 20 %, with fail safe, 150 mA / PTC
* single pair protector also available
Terminal Strips Patchcords
C39195-A332-A12
C39195-A332-A31
C39195-A332-A30
Patch cord 1 x 1000RT to 1 x 1000RT, 2 meters
Patch cord 1 x 1000RT to 1 x RJ45, 2 meters
Patch cord 2 x 1000RT to 1 x RJ45, 2 meters
Disconnection & Blind Plugs, Tools and Labeling
1
1
1
1
C39334-A117-A3
Disconnection plug for 1 wire, color brown
1
C39104-A115-C50
Color black
10 caps
C39104-A115-C53
Color red
C39334-A117-A7
Blind plug for 1 wire, color red
Marking Accessories
C39104-A115-C51
C39104-A115-C52
C39104-A115-C54
C39104-A115-C55
C39104-A115-C56
C39104-A115-C57
Termination Tools
C39407-A139-A12
C39407-A149-A15
Labeling Kits
C39104-A123-D1
C39104-A123-D7
Color white
FutureCom 10TEN
1
1
10 caps
Color gray
10 caps
Color blue
10 caps
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
S30264-D1006-S210
1
FutureCom E
4 pcs. required to install 20 terminal strips
FutureCom D
20-way mounting frames with closed jumper comb (length = 321 mm),
FutureCom UD FutureCom UE
separately
1
Hardware
2 pcs. required, mounting frames and IDC terminal strips ordered
10 caps
Color green
10 caps
Color yellow
10 caps
Color purple
10 caps
Termination Tool for connecting the wires, cutting device with lock for
optional cutting of excess wire length and extraction hook for removing wires
Extraction Tool for removing modules out of extremely narrow distribution
enclosures
Industrial
Cable
C39104-A123-B69
Horizontal 19“ bracket to install Series 1000RT mounting frames,
1
1
Special
Cable
C39393-A80-D52
IDC terminal strips ordered separately (max. 28 terminal strips; 280 pairs)
Further
Information
19“ Solutions
FutureCom F
Order Number
10 pairs
100 pairs, 1 ...100
200 pairs, 1 ...200
10 pairs
Corning Cable Systems
Introduction
IDC Terminal Strips 1000RT
163
164
Corning Cable Systems
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
FutureCom 10TEN
Telephone / ISDN Products
9.1. Cat. 3 / ISDN Telephone Patch Panels
9.2. Telephone Patch Cords
168
Corning Cable Systems
165
Introduction
166
FutureCom F
9
Further
Information
Table of contents
Cat. 3/ISDN Patch Panels and Telephone Patch Cords
Features
19“ patch panel 1U with 50 unshielded 8-pin RJ 45 jacks
Wire connection via 4-pin LSA/110 connect dual cutting
clamps for AWG 22-26
Wiring according to ISO/IEC 11801/EN 50173-1,
configuration: Pin 3/6 and Pin 4/5
Grounding via M6 screw with nut and lock washer on the
patch panel
Shield connection directly on the circuit board
Integrated cable strain relief
Ordering Information
Order Number
CAXCSV-05003-C001
Description
FutureCom™ Cat. 3/ISDN
Telephone Patch Panel,
unshielded, 50xRJ45,
Units per
Delivery
1/1
configuration 4.5 and
3.6, LSA-PLUS, 1U,
light-basic, RAL 7035
CAXCSV-05000-C001 FutureCom Cat. 3/ISDN
Telephone Patch Panel,
unshielded, 50xRJ45,
1/1
configuration 4.5 and
3.6, LSA-PLUS, 1U,
high-grade steel
166
Corning Cable Systems
Cat. 3/ISDN Patch Panels and Telephone Patch Cords
Introduction
Features
19“ patch panel 1U and 0.5U with 25 unshielded 8-pin RJ 45
jacks
Wire connection via 8-pin LSA/110 connect dual cutting
FutureCom F
clamps for AWG 22-26
Wiring according to ISO/IEC 11801/EN 50173-1,
configuration: Pin 3/6 and Pin 4/5
FutureCom 10TEN
Grounding via M6 screw with nut and lock washer on the
patch panel
Shield connection directly on the circuit board
CAXCSV-02503-C001
Description
FutureCom™ Cat. 3/ISDN
Telephone Patch Panel,
unshielded, 25xRJ45,
FutureCom D
Order Number
Units per
Delivery
1/1
FutureCom UD FutureCom UE
Ordering Information
FutureCom E
Integrated cable strain relief
configuration 4.5 and
3.6, LSA-PLUS, 1U,
FutureCom Cat. 3/ISDN
Telephone Patch Panel,
unshielded, 25xRJ45,
1/1
configuration 4.5 and
Industrial
Cable
3.6, LSA-PLUS, 1U,
Special
Cable
high-grade steel
Further
Information
CAXCSV-02500-C001
Flex Wire
Flex Wire
CableCable
Telephone /
for Patch
for Patch
Cord Cord
ISDN Products
Hardware
light-basic, RAL 7035
Corning Cable Systems
167
Cat. 3/ISDN Patch Panels and Telephone Patch Cords
Ordering Information
Order Number
CAXCSV-02503-C002
Description
FutureCom™ Cat. 3/ISDN
Telephone Patch Panel,
unshielded, 25xRJ45,
Units per
Delivery
1/1
configuration 4.5 and
3.6, LSA-PLUS, 0.5U,
light-basic, RAL 7035
CAXCSV-02500-C002 FutureCom Cat. 3/ISDN
Telephone Patch Panel,
unshielded, 25xRJ45,
1/1
configuration 4.5 and
3.6, LSA-PLUS, 0.5U,
high-grade steel
U/UTP Flex PVC Telephone Patch Cords, ISDN/Analog
Order Number
CCACOC-A6002-A005-C0
CCACOC-A6002-A010-C0
Description
ISDN Patch Cord, black, 2xRJ45 Connectors,
e.g. for ISDN & analog (So, Upo, U200,
U*, U2B1Q, analog a/b, a/b/c/d)
CCACOC-A6002-A015-C0
0.5 m
1m
1.5 m
CCACOC-A6002-A020-C0
2m
CCACOC-A6002-A025-C0
2.5 m
CCACOC-A6002-A030-C0
3m
CCACOC-A6002-A040-C0
4m
CCACOC-A6002-A050-C0
5m
CCACOC-A6002-A060-C0
6m
CCACOC-A6002-A100-C0
168
Length
10 m
Corning Cable Systems
Further
Information
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
FutureCom 10TEN
10 Cable for Patch Cords
10.1. S/FTP Flex/26 FRNC
10.2. SF/UTP Flex/26 FRNC
172
Corning Cable Systems
169
Introduction
170
FutureCom F
Table of contents
FutureCom™ Patch Cord Cable
S/FTP flex/26 FRNC
Braided shield
Halogen-free jacket,
flame retardant
Foil shielding (PiMF)
Twisted pair
PE foam-skin insulation
4 shielded pairs
Copper flex wire,
AWG 26
Mechanical Characteristics
Conductor insulation
Outer jacket
Area/range of application
Temperature range (installation)
Operating temperature
Min. bending radius
for one-time bending
Min. bending radius during
installation
Copper conductor
170
Application
FutureCom™ S/FTP flex/26 patch cord cable is designed for
applications up to 600 MHz and its transmission characteristics satisfy Category 7 specifications.
FutureCom patch cord cables are a low-skew product, i.e. the
skew between the individual pairs is very low. This is increasingly required for applications above 1 Gigabit. The cable has
a streamlined construction and low weight.
Each pair is individually shielded (PiMF). The stranded pairs
are additionally braid shielded (S/FTP), which guarantees
outstanding shielding characteristics. The cable satisfies the
standards of Class B interference radiation (EN 55022), as
well as immunitiy (EN 55024), which enables the realization
of CE-compatible networks.
Halogen free
foam-skin material
Halogen free
flame retardant
Dry and
damp rooms
0 to +50°C
-20 to +60°C
>_ 30 mm
>_ 40 mm
Features
S/FTP flex cable, specified up to 600 MHz
Outstanding electrical characteristics
Cat.7 flex wire cable
Low skew between the pairs
Suitable for IDC contacts of RJ45 connectors or
S1200 modules/connetors
Surface transfer impedance < 10 mV/m at 10 MHz
Flame retardant according to IEC 60332-1 , Category B
Unprinted
AWG 26
Corning Cable Systems
FutureCom™ Patch Cord Cable
S/FTP flex/26 FRNC
Largest resistance margin
2%
Impedance Zo at 101 - 250 MHz
100 V +/- 18%
(typical value)
at 10 MHz
Introduction
Electrical Characteristics (at 20°C)
>5000 MV x km
FutureCom F
100 V +/- 15%
100 V +/- 25%
FutureCom 10TEN
10 m V/m
43 pF/m
0.78 x c
FutureCom E
4.3 ns/m
4 ns/100 m
Delay skew
Frequency in MHz
1
Attenuation in dB/100m *
10
2.9
Typical values dB/100m
2.9
NEXT in dB at 100 m *
80.0
Typical values in dB at 100m
96.0
PSNEXT in dB at 100 m *
77.0
Typical values in dB at 100m
93.0
ELFEXT in dB at 100 m *
80.0
Typical values in dB at 100m
95.0
PSELFEXT in dB at 100 m *
77.0
Typical values in dB at 100m
92.0
ACR in dB
93.1
8.5
7.9
80.0
96.0
77.0
93.0
74.0
93.0
71.0
90.0
88.1
20
31.25
10.8
13.5
12.1
80.0
96.0
77.0
93.0
68.0
93.0
65.0
90.0
85.2
100
300
25.2
44.3
15.2
21.7
27.8
96.0
95.0
94.0
80.0
77.0
93.0
64.1
88.0
61.1
85.0
82.5
* Standard: Requirements for Category 7 flex cable (conforms with EN 50288-4-2)
Ordering Information
62.5
19.5
75.1
72.5
92.0
58.1
81.0
55.1
78.0
75.5
72.4
69.4
91.0
54.0
72.0
51.0
69.0
68.8
50.0
73.3
86.0
80.0
65.3
62.3
83.0
44.5
60.0
41.5
57.0
41.7
Type designation
Fire Load Zero
Category Pair count (MJ/m) Halogen Color
Outer [ Weight Length
(mm) (kg/km) (m)
Order Number
S/FTP flex/26
7
5.8
S/FTP flex/26
S/FTP flex/26
S/FTP flex/26
S/FTP flex/26
S/FTP flex/26
7
4
0.43
Yes
gray
7
4
0.43
Yes
green
7
7
7
4
4
4
4
0.43
0.43
0.43
0.43
Yes
Yes
Yes
Yes
blue
yellow
red
black
600
63.5
60.8
57.8
77.0
38.4
51.0
35.4
48.0
16.5
5.8
42
2000 CCXFGB-G0047-0001-L8
5.8
42
2000 CCXFGB-G0047-0004-L8
5.8
5.8
5.8
Corning Cable Systems
42
42
42
42
2000 CCXFGB-G0047-0002-L8
2000 CCXFGB-G0047-0003-L8
2000 CCXFGB-G0047-0005-L8
2000 CCXFGB-G0047-0006-L8
171
FutureCom D
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
FutureCom UD FutureCom UE
Propagation velocity
Hardware
Operating capacity
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Surface transfer impedance
Industrial
Cable
Impedance Zo at 251 - 600 MHz
Special
Cable
Impedance Zo at 1 - 100 MHz
Further
Information
Insulation resistance
FutureCom™ Patch Cord Cable
SF/UTP flex/26 FRNC
Braided shield
Halogen-free jacket,
flame retardant
Foil shield
Twisted pair
PE foam-skin insulation
4 shielded pairs
Copper flex wire,
AWG 26
Mechanical Characteristics
Conductor insulation
Outer jacket
Area/range of application
Temperature range (installation)
Operating temperature
Min. bending radius
for one-time bending
Min. bending radius during
installation
Copper conductor
172
Application
The FutureCom™ SF/UTP flex/26 patch cord cable is
specified for applications up to 300 MHz and it´s outstanding transmission characteristics satisfy Channel D (2002)
specifications.
FutureCom patch cord cables are low-skew products. This is
increasingly required for applications above 1 Gigabit. The
cable has a streamlined construction and low weight.
The stranded pairs are foil shielded and have a braided
shield (SF/UTP), which guarantees outstanding shielding
characteristics. The cable satisfies the standards for Class B
interference radiation (EN 55022), as well as immunity
(EN 55024), which enables the realization of CE-compatible
networks.
Halogen free
foam-skin material
Halogen free
flame retardant
Dry and
damp rooms
0 to +50°C
-20 to +60°C
>_ 30 mm
>_ 40 mm
Features
SF/UTP flex cable, specified up to 300 MHz
Outstanding electrical characteristics
Full copper braid shield
Cat. 5e flex cable
Low skew between the pairs
Suitable for IDC contacts, RJ45 connectors or
S1200 modules/connetors
Surface transfer impedance < 10 mV/m at 10 MHz
Flame retardant according to IEC 60332-1, Category B
Unprinted
AWG 26
Corning Cable Systems
FutureCom™ Patch Cord Cable
SF/UTP flex/26 FRNC
Largest resistance margin
3%
Surface transfer impedance
<100 m V/m
Propagation velocity
0.74 x c
Introduction
Electrical Characteristics (at 20°C)
>150 MV x km
FutureCom F
100 V +/- 15%
at 10 MHz
4.5 ns/m
10
16
20
31.25
62.5
100
Attenuation in dB/100m *
3.2
6.0
9.5
13.6
17.1
24.8
32.0
Typical values in dB at 100m
70.0
65.0
60.0
52.0
48.0
45.0
45.0
Typical values dB/100m
3.0
NEXT in dB at 100 m *
65.3
PSNEXT in dB at 100 m *
62.3
Typical values in dB at 100m
ELFEXT in dB at 100 m *
63.8
–
Typical values in dB at 100m
PSELFEXT in dB at 100 m *
60.8
–
Typical values in dB at 100m
ACR in dB
67.0
–
5.8
56.3
53.3
51.8
–
48.8
–
59.2
–
9.0
50.3
47.3
43.8
12.2
45.8
42.8
37.8
–
–
40.8
34.8
–
–
51.0
39.8
–
–
* Standard: Requirements for Category 5/5e flexible cable (conforms with EN-50288-2-2)
Ordering Information
14.7
42.9
39.9
33.9
–
30.9
–
33.3
–
22.5
38.4
35.4
27.9
–
24.9
–
22.5
–
27.3
35.3
32.3
23.8
–
20.8
–
17.7
–
Type designation
Fire Load Zero
Category Pair count (MJ/m) Halogen Color
Outer [ Weight Length
(mm) (kg/km) (m)
Order Number
SF/UTP flex/26
5e
5.7
SF/UTP flex/26
SF/UTP flex/26
SF/UTP flex/26
SF/UTP flex/26
5e
4
0.43
Yes
grey
5e
4
0.43
Yes
green
5e
5e
5e
4
4
4
4
0.43
0.43
0.43
0.43
Yes
Yes
Yes
Yes
blue
yellow
red
black
48.3
35.0
–
–
–
–
–
–
–
–
5.7
40
2000
CCXDGF-C0047-0001-L8
5.7
40
2000
CCXDGF-C0047-0004-L8
5.7
5.7
5.7
40
40
40
40
2000
2000
2000
2000
CCXDGF-C0047-0002-L8
CCXDGF-C0047-0003-L8
CCXDGF-C0047-0005-L8
CCXDGF-C0047-0006-L8
Further
Information
SF/UTP flex/26
300
–
Hardware
1
Frequency in MHz
FutureCom D
FutureCom E
7 ns/100 m
Delay skew
FutureCom UD FutureCom UE
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
FutureCom 10TEN
48 pF/m
Operating capacity
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
(typical value)
Industrial
Cable
Impedance Zo at 1 - 100 MHz
Special
Cable
Insulation resistance
Corning Cable Systems
173
174
Corning Cable Systems
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
FutureCom 10TEN
11
Further
Information
Industrial Cable
11.1. S/FTP 600/23 PUR Cable
176
11.2. SF/UTP J-09YS (ST) CH Cable
11.3. S/FTP 600 flex/26 PUR Cable
180
Corning Cable Systems
175
Introduction
178
FutureCom F
Table of contents
FutureCom™ Industrial Cable
S/FTP 600/23 PUR
Application
The FutureCom™ Industrial S/FTP 600/23 cable with
polyurethane external jacket is particularly suitable for
Braided shield
PUR sheath
Twisted pair
Foil shielding (PiMF)
PE foam-skin
insulation
Copper conductor
AWG 23
4 shielded pairs
Mechanical Characteristics
Area/range of application
Dry and
Operating temperature
Min. bending radius
for one-time bending
Min. bending radius during
installation
Copper conductor
176
This cable is specified for applications to up 800 MHz and
satisfies Category 7 specifications ISO/IEC 11801 (2002) and
EN 50173-1 (2003).
These cables are low-skew products, i.e. the skew between
the individual pairs is very low. This is increasingly required
for applications above 1 Gigabit. The cable has a streamlined
construction and low weight.
Each pair is individually shielded (PiMF). The stranded pairs
are additionally braid shielded (S/FTP), which guarantees
outstanding shielding characteristics. The cable satifies the
standard for Class B interference radiation (EN 55022), as
of CE-compatible networks.
Halogen free
Temperature range (installation)
with FutureCom metal outlets for industrial networks.
well as immunitiy (EN 55024), which enables the realization
Conductor insulation
Outer jacket
industrial applications. It is recommended in conjunction
Foam-skin material
Polyurethane
damp rooms
0 to +50°C
-20 to +60°C
>_ 40 mm
>_ 60 mm
AWG 23
Features
S/FTP 600/23 PUR cable, specified up to 800 MHz
Outstanding electrical characteristics
Each pair is shielded (PiMF)
Full copper braid shield
Streamlined design
Lightweight
Low skew between the pairs
Halogen-free (LSZH)
Flame resistant and non-corrosive
Lubricant-resistant, microbe-resistant and hydrolysisresistant
Corning Cable Systems
FutureCom™ Industrial Cable
S/FTP 600/23 PUR
Unbalance to ground
dB/BZL = 1000 m
FutureCom F
Surface transfer impedance
100 V +/- 18%
100 V +/- 25%
<10 m V/m at 10 MHz
FutureCom 10TEN
Impedance Zo at 251 - 600 MHz
125 V +/- 20%
>46 dB at 64 kHz
dB/BZL = 100 m
FutureCom E
>40 dB at 1 MHz
Unbalance to ground
>20 dB at 100 MHz
dB/BZL = 100 m
Propagation velocity
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
Delay skew
0.79 x c
FutureCom D
Unbalance to ground
4.2 ns/m
4 ns/100 m
1
Frequency in MHz
10
16
20
31.25
62.5
100
Attenuation in dB/100m*
2.0
Typical values in dB at 100m
>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0
77.0
77.0
77.0
77.0
77.0
72.5
69.4
Typical values dB/100m
5.7
1.7
NEXT in dB at 100 m *
5.0
80.0
PSNEXT in dB at 100 m*
Typical values in dB at 100m
ELFEXT in dB at 100 m*
80.0
Typical values in dB at 100m
7.3
80.0
9.2
80.0
14.5
13.2
75.1
18.5
16.9
72.4
98.0
98.0
98.0
98.0
97.0
77.0
71.0
66.9
65.0
61.1
55.1
51.0
74.0
93.0
91.0
ACR in dB
80.0
10.1
98.0
93.0
PSELFEXT in dB at 100 m*
6.5
8.1
98.0
80.0
Typical values in dB at 100m
7.2
91.0
98.3
95.0
69.9
93.0
91.0
93.5
68.0
93.0
91.0
92.7
64.1
90.0
88.0
90.8
58.1
86.0
84.0
86.8
54.0
83.0
81.0
82.1
300
600
65.3
60.8
33.3
30.7
95.0
62.3
93.0
44.5
68.0
41.5
66.0
64.3
48.9
44.0
91.0
57.8
89.0
38.4
51.0
35.4
49.0
47.0
800
53.0
–
87.0
–
85.0
–
–
–
–
34.0
–
* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
Type designation
Industrial
Cable
Ordering Information
Max
Outer [ Weight Length
Tensile
Fire Load Zero
Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m)
Order Number
Industrial S/FTP 600/23 7
4P, PUR
4
0.74
Yes
154
7.7
Corning Cable Systems
64
1000
FutureCom UD FutureCom UE
Impedance Zo at 101 - 250 MHz
>5000 MV x km
Hardware
100 V +/- 15%
Impedance Zo at 0.064 MHz
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Impedance Zo at 1 - 100 MHz
Insulation resistance
CCXIPB-F0047-C001-L7
177
Special
Cable
1%
Further
Information
Largest resistance margin
Introduction
Electrical Characteristics (at 20°C)
FutureCom™ Industrial 120V Cable
SF/UTP J-09YS (ST) CH
Halogen-free jacket,
flame retardant
Star Quad
Foil shielding
PP foil
Dummy element
Application
The FutureCom™ 120 V Industrial Cable is designed
specifically for data and voice transmission in industrial or
telecommuncations enviroments. These cables can be used
as connecting cables or for direct installation in dry as well
as damp rooms.
Braid shield
Additional wire
Foam-skin insulation
Copper conductor
AWG 24
Mechanical Characteristics
Conductor insulation
Outer jacket
Jacket color
Installation area
Temperature (installation)
Polypropylene
foam-skin material
Halogen-free, flame
retardent
Yellow (RAL 1021)
In dry and damp rooms
-5 to +50°C
Operating temperature
-30 to +70°C
Min. bending radius during
>_ 60 mm
Min. bending radius
for one-time bending
installation
Copper conductor
178
Features
Category 3 cable, specified up to 16 MHz
Category 4 cable in a quad, up to 20 MHz
Complete shielding with foil and copper braid shield
Low skew between the pairs
Halogen-free, LSZH (low smoke, zero halogen)
Flame retardant according to IEC 60332-3, Category C
>_ 42 mm
AWG 24
Corning Cable Systems
Frequency in MHz
0.772
1
4
10
16
20
Typical values in dB at 100 m, Quad
66
65.8
53.0
44.3
42.4
41.2
Typical values in dB/100 m
1.5
Typical values in dB at 100 m, Cable
61.5
1.75
58.9
3.3
47.2
4.9
40.3
6.8
36.9
7.6
34.7
End to end in different cables (2x60m)
End to end in different cables (2x60m)
$ 75 dB
Shield attenuation (30 to 900 MHz)
Operating Voltage
Testing Voltage
(conductor/conductor, conductor/
shielding at 50 Hz, 1 min)
Ordering Information
Type designation
J-09YS(ST)CH 4x2x0,5 BD 120 V
FutureCom D
Max. attenuation at 1 MHz
$ 50 dB
# 19 dB/1000m
$ 80 dB
FutureCom UD FutureCom UE
End to end in the same quad
300 Vss
800 Vss
Hardware
ELFEXT at 1 MHz
FutureCom E
$ 50 dB
$ 75 dB
Zero
Outer[ Weight Length
(kg/km) (m)
Category Pair count Halogen mm
Order Number
3
4
Yes
7,5
80
1000
CCXIEO-A0027-C001-L7
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
End to end in the same quad
120 V +/- 15V
Industrial
Cable
NEXT at 1 MHz
$ 10 GV x km
Special
Cable
Impedance Zo at 0.064 MHz
Further
Information
Insulation resistance
FutureCom 10TEN
Electrical Characteristics (at 20°C)
FutureCom F
Electrical Characteristics (at 20°C)
Introduction
FutureCom™ Industrial 120V Cable
SF/UTP J-09Ys (ST) CH
Corning Cable Systems
179
FutureCom™ Industrial S/FTP 600flex/26 PUR Cat. 7
Application
Braided shield
PUR jacket
Foil shielding (PiMF)
Twisted pair
PE foam-skin
insulation
4 shielded pairs
Copper flex wire
AWG 26
Mechanical Characteristics
Conductor insulation
Outer jacket
Area/range of application
Temperature range (installation)
Operating temperature
Min. bending radius
for one-time bending
Min. bending radius during
installation
Copper conductor
180
Halogen-free
foam skin material
Halogen free
Flame retardent
In dry and damp rooms
0 to +50°C
-20 to +60°C
>_ 30 mm
>_ 40 mm
AWG 26
The Industrial S-STP 600 flex cable with polyurethane jacket
is specially designed for industrial use. It is specified up to
600 MHz and satisfies Category 7 standards, ISO/IEC 11801
(2002) and EN 50173-1 (2003).
FutureCom™ cables are low skew products, i.e. the skew be-
tween the individual pairs is very low. This is increasingly
being requested for applications above Gigabit Ethernet.
Additional features are the slim design and low weight of
the cables.
Each pair is individually shielded (PiMF). The stranded pairs
are additionally sheathed with a braid shield (S/FTP), which
guarantees outstanding shielding characteristics. The cable
satisfies Class B interference radiation standards (EN 55022),
as well as immunity (EN 55024), which enables the realization of CE-compatible networks.
Features
S/FTP 600 flex/26 PUR flex cable,
specified up to 600 MHz
Outstanding electrical characteristics
Each pair is foil-shielded (PiMF)
Full copper braid shield
Streamlined design
Lightweight
Low skew between the pairs
Halogen-free (LSZH)
Flame resistant and non-corrosive
Lubricant-, microbe- and hydrolysis resistant
Unprinted
Corning Cable Systems
FutureCom™ Industrial S/FTP 600flex/26 PUR Cat. 7
Impedance Zo at 101 - 250 MHz
100 V +/- 18%
Operating capacity
43 pF/m
>5000 MV x km
Insulation resistance
FutureCom F
100 V +/- 15%
Impedance Zo at 1 - 100 MHz
100 V +/- 25%
Impedance Zo at 251 - 600 MHz
FutureCom 10TEN
<10 m V/m at 10 MHz
Surface transfer impedance
0.78 x c
Propagation velocity at >10 MHz
Propagation delay >_ 10 MHz
4.3 ns/m
80.0
80.0
8.5
Typical values in dB at 100m
96.0
96.0
Typical values dB/100m
2,9
NEXT in dB at 100 m *
80.0
PSNEXT in dB at 100 m*
77.0
Typical values in dB at 100m
93.0
ELFEXT in dB at 100 m*
80.0
Typical values in dB at 100m
95.0
PSELFEXT in dB at 100 m*
77.0
Typical values in dB at 100m
92.0
ACR in dB
93.1
7.9
77.0
93.0
74.0
93.0
71.0
90.0
88.1
31.25
62.5
100
300
600
65.3
60.8
12.1
15.2
21.7
27.8
50.0
96.0
96.0
95.0
94.0
86.0
10.8
77.0
93.0
68.0
93.0
65.0
90.0
85.2
* Standard: Requirements for Category 7 flex cable (conforms with EN 50288-4-2)
13.5
80.0
77.0
93.0
64.1
88.0
61.1
85.0
82.5
19.5
75.1
72.5
92.0
58.1
81.0
55.1
78.0
75.5
25.2
72.4
69.4
91.0
54.0
72.0
51.0
69.0
68.8
44.3
62.3
83.0
44.5
60.0
41.5
57.0
41.7
73.3
FutureCom D
20
2.9
63.5
80.0
FutureCom UD FutureCom UE
10
Attenuation in dB/100m*
57.8
77.0
38.4
51.0
35.4
48.0
16.5
Hardware
1
Frequency in MHz
FutureCom E
4 ns/100 m
Delay skew
Ordering Information
7
4
0.43
Yes
5.8
42
1333
CCXIHB-G0047-0007-H2
Special
Cable
Industrial S-STP 600flex/26 4P
Outer[ Weight Length
Fire Load Zero
(kg/km) (m)
Category Pair count (MJ/m) Halogen mm
Order Number
Further
Information
Type designation
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
2%
Industrial
Cable
Largest resistance margin
Introduction
Electrical Characteristics (at 20°C)
Corning Cable Systems
181
182
Corning Cable Systems
186
12.2.2. U/UTP 100/24
190
12.3.1. Fiber Blow S/FTP 900
192
12.2.2. F/UTP 300/24
12.3. Hybrid Cable
12.3.2. Fiber Blow S/FTP 600
188
194
12.3.3. S/FTP 600/23 4P + J-VH 4G50 FRNC
196
12.4.1. Cat. 6 Star Quad S/FTP 600/22 FRNC
198
12.4. ViMF Cable
12.4.2. Star Quad U/FTP 300/23 FRNC
202
Further
Information
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
12.4.3. Star Quad U/FTP 300/23 PVC
200
FutureCom F
12.2.1. S/FTP 600/23 with Diffusion Barrier
FutureCom 10TEN
12.2. Outdoor Cable
FutureCom E
184
FutureCom D
12.1. F/UTP 450/23 FRNC Cable
FutureCom UD FutureCom UE
12 Special Cable
Introduction
Table of contents
Corning Cable Systems
183
FutureCom™ Cat. 6 Cable
F/UTP 450/23
Application
Halogen-free jacket,
flame retardent
Foil shielding
Foil shielding
Twisted pair
PE foam-skin
insulation
Additional wire
Central cross member
Copper conductor
AWG 23
Mechanical Characteristics
Conductor insulation
Outer jacket
Area/range of application
Temperature range (installation)
Operating temperature
Min. bending radius
for one-time bending
Min. bending radius during
installation
Copper conductor
184
Halogen-free,
foam-skin material
Halogen free
Flame retardent
In dry and damp rooms
0 to +50°C
-20 to +60°C
>_ 40 mm
>_ 60 mm
The FutureCom™ F/UTP 450/23 cable is designed for applications up to 450 MHz and exceeds all the requirements for
Category 6 specifications.
FutureCom cables are low-skew products, i.e. the skew
between the individual pairs is very low. This is increasingly
required for applications above 1 Gigabit-Ethernet. These
cables have a streamlined construction and low weight.
The four stranded pairs are foil shielded (F/UTP). The cable
satisfies Class B interference radiation standards (EN 55022)
as well as immunity (EN 55024) which enables the realization of CE-compatible networks.
Features
F/UTP 450/23 cable, specified up to 450 MHz
Outstanding electrical characteristics
Twisted pairs with 2 foil shields
Low skew between the pairs
Halogen-free
Flame retardant according to IEC 60332-1, Category B
Non-corrosive according to IEC 60754-2 and EN 50267
Low-smoke according to IEC 61034
AWG 23
Corning Cable Systems
20
64.0
57.3
54.2
52.8
ELFEXT in dB at 100 m per Standard *
66.0
Near-end crosstalk loss in DB per Standard *
66.0
PSNEXT in dB at 100 m per Standard *
PSELFEXT in dB at 100 m per Standard *
64.0
ACR in dB
63.9
7.6
59.3
56.2
50.0
47.0
43.0
53.3
100
250
49.9
45.4
42.3
36.3
44.0
40.1
41.0
48.6
62.5
10.7
54.8
45.9
31.25
8.5
46.3
51.9
37.1
41.2
15.5
47.4
34.1
31.1
31.9
19.9
44.3
30.0
27.0
24.4
* Standard: Requirements for 100 m installed Category 6 cable for Class E cabling links (conforms with EN 50288-5-1)
Ordering Information
Yes
Max.
Tensile
Strength Outer[ Weight Length
(kg/km) (m)
Order Number
mm
(N)
104
6.7
49
1000
CCXCDE-B0047-C001-L7
Hardware
0.76
5.3
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
4
19.0
Industrial
Cable
6
22.0
Special
Cable
F/UTP 450/23 4P
Fire Load Zero
Category Pair count (MJ/m) Halogen
38.3
Further
Information
Type designation
33.0
FutureCom F
16
6.0
FutureCom 10TEN
10
2.1
FutureCom E
1
Attenuation in dB/100m per Standard *
FutureCom D
Frequency in MHz
FutureCom UD FutureCom UE
Electrical Characteristics (at 20°C)
Introduction
FutureCom™ Cat. 6 Cable
F/UTP 450/23
Corning Cable Systems
185
FutureCom™ Cat. 7 Outdoor Cable
S/FTP 600/23 with Diffusion Barrier
PE sheath
Layered aluminum
band
Braided shield
Twisted pair
Foil shielding (PiMF)
PE foam-skin
insulation
Copper conductor
AWG 23
FRNC interior sheath
4 shielded pairs
Mechanical Characteristics
Halogen free/
Area/range of application
Outdoor installation
Temperature range (installation)
Operating temperature
Min. bending radius
for one-time bending
Min. bending radius during
installation
Copper conductor
The FutureCom™ S/FTP 600/23 data cable with diffusion
barrier is specified up to 800 MHz. It’s transmission
characteristics satisfy Category 7 specifications according to
ISO/IEC 11801 (2002) and EN 50173-1 (2003).
FutureCom cables are low-skew products, i.e.the skew
between the individual pairs is very low. As a result of the
aluminum composite layer sheath, this cable is suitable for
direct burial. The cable has a streamlined construction and
low weight.
Each pair is individually shielded (PiMF). The stranded pairs
are sheathed with a braided shield (S/FTP), which guaran-
tees outstanding shielding characteristics. The cable satisfies the standard for Class B interference radiation
(EN 55022), as well as immunitiy (EN 55024), which enables
the realization of CE-compatible networks.
Conductor insulation
Outer jacket
Application
foam-skin material
Halogen free
0 to +50°C
-20 to +60°C
<_ 175 mm
<_ 235 mm
AWG 23
Features
S/FTP 600/23 cable, specified up to 800 MHz
Outstanding electrical characteristics
Each pair is shielded (PiMF)
Full copper braid shield
Streamlined design
Lightweight
Low skew between the pairs
Includes a diffusion barrier
(aluminum band and PE sheath)
Halogen-free (LSZH)
Interior sheath flame retardant according to
IEC 60332-3 and EN 50266-2-4
Interior sheath non-corrosive according to
IEC 60754-2 and EN 50267
Interior sheath low smoke according to IEC 61034
Can be directly buried
186
Corning Cable Systems
FutureCom™ Cat. 7 Outdoor Cable
S/FTP 600/23 with Diffusion Barrier
Introduction
Electrical Characteristics (at 20°C)
1%
> 5000 MV x km
125 V +/- 20%
FutureCom F
100 V +/- 15%
100 V +/- 18%
100 V +/- 25%
Impedance Zo at 251 - 600 MHz
FutureCom 10TEN
<10 m V/m at 10 MHz
Surface transfer impedance
>46 dB at 64 kHz
Unbalance to ground
dB/BZL = 1000 m
dB/BZL = 100 m
FutureCom E
>40 dB at 1 MHz
Unbalance to ground
>20 dB at 100 MHz
Unbalance to ground
dB/BZL = 100 m
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
FutureCom D
0.79 x c
Propagation velocity
4.2 ns/m
4 ns/100 m
Delay skew
1
Frequency in MHz
Attenuation in dB/100m *
2.0
Typical values dB/100m
1.7
NEXT in dB at 100 m *
80.0
10
5.7
5.0
16
7.2
6.5
20
31.25
8.1
10.1
7.3
9.2
62.5
14.5
13.2
100
18.5
16.9
80.0
80.0
80.0
80.0
75.1
72.4
>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0
77.0
77.0
77.0
77.0
77.0
72.5
69.4
Typical values in dB at 100m
PSNEXT in dB at 100 m *
Typical values in dB at 100m
ELFEXT in dB at 100 m *
98.0
98.0
98.0
98.0
98.0
98.0
97.0
77.0
71.0
66.9
65.0
61.1
55.1
51.0
80.0
Typical values in dB at 100m
93.0
PSELFEXT in dB at 100 m *
Typical values in dB at 100m
91.0
ACR in dB
98.3
74.0
93.0
91.0
95.0
69.9
93.0
91.0
93.5
68.0
64.1
93.0
90.0
91.0
88.0
92.7
90.8
58.1
86.0
84.0
86.8
54.0
83.0
81.0
82.1
300
600
65.3
60.8
33.3
30.7
95.0
62.3
93.0
44.5
68.0
41.5
66.0
64.3
48.9
44.0
91.0
57.8
89.0
38.4
51.0
35.4
49.0
47.0
800
53.0
–
87.0
–
85.0
–
–
–
–
34.0
–
* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
S/FTP 600/23 4P
Industrial
Cable
Ordering Information
Type designation
Max
Outer [ Weight Length
Tensile
Fire Load Zero
Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m)
Order Number
7
4
2.98
Yes
400
11.7
Corning Cable Systems
126
1000
FutureCom UD FutureCom UE
Impedance Zo at 101 - 250 MHz
Hardware
Impedance Zo at 1 - 100 MHz
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Impedance Zo at 0.064 MHz
CCXSDB-F0047-C001-L7
187
Special
Cable
Insulation resistance
Further
Information
Largest resistance margin
FutureCom™ Cat. 5e Outdoor Cable
F/UTP 300/24 PE
Foil shielding
PE-outer sheath
2 wires stranded to a
pair
Foil shielding
Additional wire
PE foam-skin PE
insulation
Copper conductor
AWG 24
Color Coding
4 shielded pairs
Pair 1
White with blue rings/blue
Pair 4
White with brown rings/brown
Pair 2
Pair 3
White with orange rings/orange
Wire insulation
Halogen free
Area/range of application
Outdoor installation
Sheath material
Temperature range (in motion)
PE foam-skin material
PE
0 to +50°C
Operating temperature
-60 to +60°C
Min. bending radius
>50 mm
Min. bending radius
for one-time bending
Diameter of the copper conductor
188
The FutureCom™ F/UTP 300/24 PE cable is designed for out-
door applications up to 300 MHz and provides transmission
performance exceeding Category 5e ISO/IEC 11801 (2002)
and EN 50173-1 (2003) specifications.
The improved operating temperature of up to -60°C is
appropriate for the use under most adverse conditions.
This cables are low skew products, i.e. the difference in propagation delay between the individual pairs is
very low. This is increasingly being requested for Gigabit
Ethernet. The cable as a streamlined construction and low
weight.
The stranded pairs are surrounded by foils (F/UTP).
The cable satisfies Class B interference radiation
(EN 55022), as well as immunity (EN 55024), which enables
the realization of CE-compatible networks.
White with green rings/green
Mechanical Characteristics
during installation
Application
>35 mm
AWG 24
Features
F/UTP 300/24 PE cable, specified up to 300 MHz
Outdoor cable specified up to -60°C
Excellent electrical characteristics
Full shielding including 2 foils with additional tinned
copper wire
Slim design
Lightweight
Low skew between the pairs
PE jacket
Corning Cable Systems
FutureCom™ Cat. 5e Outdoor Cable
F/UTP 300/24 PE
Introduction
Electrical Characteristics (at 20°C)
2%
>5000 MV x km
185 V/km
Surface transfer impedance
<10 m V/m at 10 MHz
Unbalance to ground
>40 dB at 1 MHz
FutureCom F
100 V +/- 15%
dB/BZL = 1000 m
dB/BZL = 100 m
FutureCom 10TEN
>46 dB at 64 kHz
Unbalance to ground
dB/BZL = 100 m
FutureCom E
>20 dB at 100 MHz
Unbalance to ground
0.74 * c
Propogation velocity
at >10 MHz (NVP * c)
4.5 ns/m
Signal delay >10 MHz
FutureCom D
7 ns/100 m
Delay margin
Frequency in MHz
1
NEXT in dB at 100 m to standard*
65.3
Attenuation in dB/100m according to standard*
Typical values dB/100m
Typical values in dB at 100m
PSNEXT in dB at 100 m according to standard*
Typical values in dB at 100m
ELFEXT in dB at 100 m according to standard*
Typical values in dB at 100m
PSELFEXT in dB at 100 m according to standard*
Typical values in dB at 100m
ACR in dB
10
16
20
31.25
62.5
100
38.4
35.3
2.1
6.3
8.0
9.0
11.4
16.5
77.0
62.0
59.0
57.0
54.0
50.0
2.0
5.6
50.3
62.3
47.3
75.0
60.0
63.8
43.8
72.0
60.0
60.8
40.8
70.0
58.0
74.9
55.9
7.2
47.3
44.2
57.0
39.7
54.0
36.7
52.0
51.4
8.0
45.8
42.8
55.0
37.8
52.0
34.8
50.0
48.5
10.1
42.9
39.9
52.0
33.9
48.0
30.9
46.0
43.5
21.3
14.4
35.4
48.0
27.9
40.0
24.9
38.0
34.9
18.2
46.0
32.3
44.0
23.8
34.0
20.8
32.0
26.7
250
29.5
–
38.5
–
36.5
–
22.1
–
20.1
–
7.0
300
32.2
–
35.0
–
33.0
–
17.0
–
15.0
–
0.9
* Standard: Requirements for 100 m installed Category 5e cable for Class D cabling sections (corresponds to EN 50288-2-1)
Ordering Information
F/UTP 300/24 PE
5e
4
No
-60°C
82
6,2
36
1000
Industrial
Cable
Std.
Max
Outer [ Weight Length
Min. Tem- Tensile
Zero
Category Pair count Halogen perature Strength (N) (mm) (kg/km) (m)
Order Number
CCXDAE-C0047-C001-L7
Further
Information
Type designation
FutureCom UD FutureCom UE
Impedance Zo at 1 - 100 MHz
Hardware
DC resistance
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Insulation resistance
Special
Cable
Largest resistance margin
Corning Cable Systems
189
FutureCom™ Cat. 5e Outdoor Cable
U/UTP 100/24 PE
PE-outer jacket
2 wires stranded to a
pair
PE foam-skin PE
insulation
4 unshielded pairs
Copper conductor
AWG 24
Color Coding
Pair 1
White with blue rings/blue
Pair 4
White with brown rings/brown
Pair 2
Pair 3
White with orange rings/orange
White with green rings/green
Mechanical Characteristics
Wire insulation
Halogen free
Area/range of application
Outdoor installation
PE foam-skin material
Application
The FutureCom™ U/UTP 100/24 PE cables are designed for
outdoor applications up to 100 MHz and provides transmission performance exceeding Category 5e ISO/IEC 11801
(2002) and EN 50173-1 (2003) specifications. The improved
operating temperature of up to -60°C/-40°C is appropriate
for the employment under most, even adverse, conditions.
This cables are low skew products, i.e. the difference in propagation delay between the individual pairs is very low. This
is increasingly being requested for e.g. Gigabit Ethernet.
The cable has a streamlined construction and low weight.
The cable satisfies Class B interference radiation (EN 55022),
as well as immunity (EN 55024), which enables the
realization of CE-compatible networks.
Features
U/UTP 100/24 cable , specified up to 100 MHz
Outdoor cable specified up to -40°C/-60°C
PE
Excellent electrical characteristics
Operating temperature
-60 to +60°C
Lightweight
Min. bending radius
>50 mm
Sheath material
Temperature range (in motion)
Min. bending radius
for one-time bending
during installation
Diameter of the copper conductor
190
0 to +50°C
>35 mm
Core and pairs are unshielded
Slim design
Low skew between the pairs
PE jacket
AWG 24
Corning Cable Systems
FutureCom™ Cat. 5e Outdoor Cable
U/UTP 100/24 PE
FutureCom F
45 pF/m
4.5 ns/m
Signal delay >10 MHz
7 ns/100 m
Delay margin
Frequency in MHz
1
10
16
20
31.25
62.5
100
NEXT in dB at 100 m to standard*
65.3
50,3
47,3
45,8
42,9
38.4
35.3
Attenuation in dB/100m according to standard*
2.1
Typical values dB/100m
1.9
Typical values in dB at 100m
77.4
PSNEXT in dB at 100 m according to standard*
62.3
Typical values in dB at 100m
74.0
ELFEXT in dB at 100 m according to standard*
63.8
Typical values in dB at 100m
68.0
PSELFEXT in dB at 100 m according to standard*
60.8
Typical values in dB at 100m
66.0
ACR in dB
74.1
6.3
5.9
65.5
47.3
60.0
43.8
49.0
40.8
47.0
56.1
8.0
7.4
62.2
44.2
56.0
39.7
45.0
36.7
43.0
50.6
9.0
8.4
59.7
42.8
54.0
37.8
42.0
34.8
40.0
47.6
11.4
10.5
57.7
39.9
51.0
33.9
40.0
30.9
38.0
42.5
16.5
15.1
49.6
35.4
47.0
27.9
33.0
24.9
31.0
33.9
21.3
19.3
46.6
32.3
44.0
23.8
28.0
20.8
26.0
26.7
*Standard: Requirements for 100 m installed Category 5e cable for Class D cabling sections (corresponds to EN 50288-3-1)
Ordering Information
Type designation
Std.
Max
Outer [ Weight Length
Min. Tem- Tensile
Zero
Category Pair count Halogen perature Strength (N) (mm) (kg/km) (m)
Order Number
U/UTP 100/24 PE
5e
4
4
No
No
-40°C
-60°C
82
82
5.4
5.4
28
28
1000
1000
CCXUAE-C0047-C001-L7
CCXUAE-C0047-C002-L7
Special
Cable
5e
Further
Information
U/UTP 100/24 PE
FutureCom E
at >10 MHz (NVP * c)
FutureCom 10TEN
0.74 x c
Propogation velocity
FutureCom D
Mutual capacity
FutureCom UD FutureCom UE
100 V +/- 15%
185 V/km
DC resistance
Hardware
Impedance Zo at 1 - 100 MHz
>5000 MV x km
Insulation resistance
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
3%
Industrial
Cable
Largest resistance margin
Introduction
Electrical Characteristics (at 20°C)
Corning Cable Systems
191
FutureCom™ Hybrid-Cable
Fiber Blow S/FTP 900/23
Braided shield
Halogen-free jacket,
flame retardant
Twisted pair
Foil shielding (PiMF)
4 shielded pairs
PE foam-skin insulation
Copper conductor
AWG 23
Tube for
insertion of fibers
Application
The FutureCom™ S/FTP 900/23 fiber blow is prepared for the
subsequent insertion of up to 12 fibers (single or multimode
fibers with 250 µm diameter can be inserted). Future-proof
cabling, for example fiber-to-the-desk (FTTD), can be easily
realized. The integrated copper data cable is specified for applications up to 1000 MHz and its transmission characteristics satisfy Category 7 specifications according to ISO/IEC
11801 (2002) and EN 50173-1 (2003).
FutureCom cables are low-skew products, i.e. the skew
between the individual pairs is very low. This is increasingly
required for applications above 1 Gigabit. The cable has a
streamlined construction and low weight. Each pair is
individually shielded (PiMF). The stranded pairs are sheathed
with a braided shield (S/FTP), which guarantees outstanding
shielding characteristics. The cable satisfies the standards
for Class B interference radiation (EN 55022), as well as
immunity (EN 55024), which enables the realization of
Mechanical Characteristics
Conductor insulation
Outer jacket
Area/range of application
Temperature range (installation)
Operating temperature
CE-compatible networks.
Halogen free
foam-skin material
Halogen free
flame retardant
Dry and
damp rooms
0 to +50°C
-20 to +60°C
Min. bending radius
>_ 100 mm
installation
(over flat side*)
for one-time bending
Min. bending radius during
Copper conductor
(over flat side*)
>_ 100 mm
Features
Fiber blow S/FTP 900/23, specified up to 1000 MHz
Outstanding electrical characteristics
Each pair is individually shielded with foil
Full copper braid shield
Low skew between the pairs
Prepared for the subsequent insertion of up to 12 fibers
Halogen-free (LSZH)
Flame retardant according to IEC 60332-3, Category C
Non-corrosive according to IEC 60754-2 (FRNC)
Low smoke according to IEC 61034
AWG 23
* Max. cabling length of 90 m with 12 x 90° bends for a radius of 100 mm
192
Corning Cable Systems
FutureCom™ Hybrid-Cable
Fiber Blow S/FTP 900/23
100 V +/- 15%
FutureCom F
125 V +/- 20%
100 V +/- 18%
Impedance Zo at 101 - 250 MHz
100 V +/- 25%
Impedance Zo at 251 - 600 MHz
FutureCom 10TEN
<10 m V/m at 10 MHz
Surface transfer impedance
>46 dB at 64 kHz
Unbalance to ground
dB/BZL = 1000 m
dB/BZL = 100 m
FutureCom E
>40 dB at 1 MHz
Unbalance to ground
>20 dB at 100 MHz
Unbalance to ground
dB/BZL = 100 m
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
FutureCom D
0.79 x c
Propagation velocity
4.2 ns/m
4 ns/100 m
Delay skew
Frequency in MHz
1
NEXT in dB 100 m *
80.0
Attenuation in dB/100m*
2.0
Typical values dB/100m
1.7
Typical values in dB at 100m
10
5.7
5.0
80.0
16
7.2
6.5
80.0
20
8.1
7.3
80.0
31.25
10.1
9.2
80.0
62.5
100
75.1
72.4
14.5
13.2
18.5
16.8
300
600
65.3
60.8
33.3
30.0
>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0
77.0
77.0
77.0
77.0
77.0
72.5
69.4 62.3
PSNEXT in dB at 100 m*
Typical values in dB at 100m
ELFEXT in dB at 100 m*
98.0
98.0
98.0
98.0
98.0
98.0
98.0
94.0
77.0
71.0
66.9
65.0
61.1
55.1
51.0
41.5
80.0
Typical values in dB at 100m
93.0
PSELFEXT in dB at 100 m*
Typical values in dB at 100m
91.0
ACR in dB
98.3
74.0
93.0
91.0
95.0
69.9
93.0
91.0
93.5
68.0
93.0
91.0
92.7
64.1
90.0
88.0
90.8
58.1
86.0
84.0
86.8
54.0
83.0
81.0
83.2
44.5
68.0
66.0
66.0
48.9
42.5
92.0
57.8
90.0
38.4
51.0
35.4
49.0
49.5
900
55.0
–
86.0
–
84.0
–
–
1000
59.0
–
83.0
–
81.0
–
–
–
–
–
–
–
–
31.0
24.0
Industrial
Cable
* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
Ordering Information
S/FTP 900/23 4P
Fiber Blow
7
4
0.6
Yes
154
7.5x16
Corning Cable Systems
118
500
Special
Cable
Type designation
Max
Outer [ Weight Length
Tensile
Fire Load Zero
Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m)
Order Number
WCXWDW-I0047-C001-L6
193
Further
Information
Impedance Zo at 0.064 MHz
FutureCom UD FutureCom UE
Impedance Zo at 1 - 100 MHz
>5000 MV x km
Insulation resistance
Hardware
1%
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Largest resistance margin
Introduction
Electrical Characteristics (at 20°C)
FutureCom™ Hybrid-Cable
Fiber Blow S/FTP 600/23
Braided shield
Halogen-free jacket,
flame retardant
Twisted pair
Foil shielding (PiMF)
4 shielded pairs
PE foam-skin insulation
Copper conductor
AWG 23
Tube for
insertion of fibers
Application
The FutureCom™ S/FTP 600/23 fiber blow is prepared for the
subsequent insertion of up to 12 fibers (single or multimode
fibers with 250 µm diameter can be inserted). Future-proof
cabling, for example fiber-to-the-desk (FTTD), can be easily
realized. The integrated copper data cable is specified for applications up to 800 MHz and its transmission characteristics satisfy Category 7 specifications according to ISO/IEC
11801 (2002) and EN 50173-1 (2003).
FutureCom cables are low-skew products, i.e. the skew
between the individual pairs is very low. This is increasingly
required for applications above 1 Gigabit. The cable has a
streamlined construction and low weight. Each pair is individually shielded (PiMF). The stranded pairs are sheathed
with a braided shield (S/FTP), which guarantees outstanding
shielding characteristics. The cable satisfies the standards
for Class B interference radiation (EN 55022), as well as
immunity (EN 55024), which enables the realization of
Mechanical Characteristics
Conductor insulation
Outer jacket
Area/range of application
Temperature range (installation)
Operating temperature
CE-compatible networks.
Halogen free
foam-skin material
Halogen free
flame retardant
Dry and
damp rooms
0 to +50°C
-20 to +60°C
Min. bending radius
>_ 100 mm
installation
(over flat side*)
for one-time bending
Min. bending radius during
Copper conductor
(over flat side*)
>_ 100 mm
Features
Fiber blow S/FTP 600/23 cable, specified up to 800 MHz
Outstanding electrical characteristics
Each pair is individually shielded with foil
Full copper braid shield
Low skew between the pairs
Prepared for the subsequent insertion of up to 12 fibers
Halogen-free (LSZH)
Flame retardant according to IEC 60332-3, Category C
Non-corrosive according to IEC 60754-2 (FRNC)
Low smoke according to IEC 61034
AWG 23
* Max. cabling length of 90 m with 12 x 90° bends with
regard to a radius of 100 mm
194
Corning Cable Systems
FutureCom™ Hybrid-Cable
Fiber Blow S/FTP 600
100 V +/- 15%
FutureCom F
125 V +/- 20%
100 V +/- 18%
Impedance Zo at 101 - 250 MHz
100 V +/- 25%
Impedance Zo at 251 - 600 MHz
FutureCom 10TEN
<10 m V/m at 10 MHz
Surface transfer impedance
>46 dB at 64 kHz
Unbalance to ground
dB/BZL = 1000 m
dB/BZL = 100 m
FutureCom E
>40 dB at 1 MHz
Unbalance to ground
>20 dB at 100 MHz
Unbalance to ground
dB/BZL = 100 m
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
FutureCom D
0.79 x c
Propagation velocity
4.2 ns/m
4 ns/100 m
Delay skew
Frequency in MHz
1
10
16
20
80.0
80.0
80.0
80.0
31.25
62.5
100
80.0
75.1
72.4
300
600
Attenuation in dB/100m *
2.0
33.3
48.9
Typical values in dB at 100m
Typical values in dB at 100m
>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0
77.0
77.0
77.0
77.0
77.0
72.5
69.4
62.3
98.0
98.0
98.0
98.0
98.0
98.0
98.0
94.0
92.0
PSELFEXT in dB at 100 m *
77.0
Typical values dB/100m
1.7
NEXT in dB 100 m *
PSNEXT in dB at 100 m *
ELFEXT in dB at 100 m *
Typical values in dB at 100m
ACR in dB
7.2
5.0
6.5
8.1
7.3
10.1
9.2
14.5
13.2
18.5
16.8
30.0
65.3
80.0
74.0
69.9
68.0
64.1
58.1
54.0
44.5
91.0
91.0
91.0
91.0
88.0
84.0
81.0
66.0
93.0
Typical values in dB at 100m
5.7
98.3
93.0
93.0
71.0
66.9
95.0
93.5
93.0
65.0
92.7
90.0
61.1
90.8
86.0
55.1
86.8
83.0
51.0
83.2
68.0
41.5
66.0
42.5
60.8
57.8
90.0
38.4
51.0
35.4
49.0
49.5
800
53.0
–
87.0
–
85.0
–
–
–
–
34.0
–
* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
S/FTP 600/23 4P
Fiber Blow
Max
Outer [Weight Length
Tensile
Fire Load Zero
Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number
7
4
0.6
Yes
154
7.5x16 118
Corning Cable Systems
500
Special
Cable
Type designation
Industrial
Cable
Ordering Information
WCXWDW-F0047-C001-L6
195
Further
Information
Impedance Zo at 0.064 MHz
FutureCom UD FutureCom UE
Impedance Zo at 1 - 100 MHz
>5000 MV x km
Insulation resistance
Hardware
1%
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Largest resistance margin
Introduction
Electrical Characteristics (at 20°C)
FutureCom™ Hybrid Cable
S/FTP 600/23 4P + J-VH 4G50 FRNC
Braided shield
Halogen-free jacket,
flame retardant
Twisted pair
Foil shielding (PiMF)
4 shielded pairs
PE foam-skin insulation
Copper conductor AWG 23
Halogen-free jacket,
flame retardant
Rip-cord
900 µm tight buffered fiber
Fiber
Strain relief
(aramide yarn)
Application
LANscape® Hybrid cables enable the simultaneous installa-
tion of a fiber optic and copper data cable.
Corning fiber optic multifiber interior cables (MIC) are par-
ticularly suitable for installation into cable conduits or ducts
(both vertically and horizontally), false floors, as jumpers or
adapter cables and for connecting workstations inside buildings (FTTD - Fiber-to-the-Desk). They can also be used as inter-building connecting cables in dry conduits. The 900µm
tight-buffer design allows easy and direct field connectorization.
The FutureCom™ S/FTP 600/23 copper cable is specified for
applications up to 800 MHz and its transmission characteristics satisfy Category 7 specifications according to ISO/IEC
11801 (2002) and EN 50173-1 (2003). A high level of system
performance for the complete channel is achieved by using
this high-quality Category 7 cable.
The low skew between the pairs emphasizes their suitability
for applications above 1 Gigabit Ethernet. Due to its out-
standing shielding characteristics, the cable satisfies the
standards for Class B interference radiation (EN 55022), as
well as immunity (EN 55024), which enables the realization
of CE-compatible networks.
Features
Fiber Optic Cable
FO cable with 900µm tight-buffered fibers,
TB-3 construction enables easy, consistent stripping
Particularly suitable for field-installable UniCam®
connectors
Telecordia color-coding
Completely dry construction
Copper Cable
S/FTP 600/23 cable, specified up to 800 MHz
Outstanding electrical characteristics
Each pair is individually shielded with foil
Full copper braid shield
Low skew between the pairs
Halogen-free (LSZH)
Flame retardant according to IEC 60332-3, Category C
Non-corrosive according to IEC 60754-2 (FRNC)
Low smoke according to IEC 61034
196
Corning Cable Systems
foam-skin material
Outer jacket
Halogen free
flame retardant
Area/range of application
0 to +50°C
Operating temperature
-20 to +60°C
Min. bending radius
>_ 40 mm (for 2x
installation
(4x2...) over flat side)
(4x2...) over flat side)
for one-time bending
>_ 60 mm (for 2x
Min. bending radius during
Copper conductor
AWG 23
Frequency in MHz
Largest resistance margin
1%
Impedance Zo at 1 - 100 MHz
100 V +/- 15%
Impedance Zo at 0.064 MHz
1
10
16
100 V +/- 18%
Unbalance to ground
>46 dB at 64 kHz
80.0
80.0
80.0
dB/BZL = 1000 m
dB/BZL = 100 m
dB/BZL = 100 m
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
Typical values in dB at 100m
>100.0 >100.0 >100.0 >100.0
5.7
NEXT in dB 100 m *
PSNEXT in dB at 100 m *
5.0
77.0
Typical values in dB at 100m
77.0
98.0
ELFEXT in dB at 100 m *
98.0
80.0
Typical values in dB at 100m
74.0
93.0
PSELFEXT in dB at 100 m * *
93.0
77.0
Typical values in dB at 100m
71.0
91.0
ACR in dB
91.0
98.3
95.0
7.2
6.5
77.0
98.0
69.9
93.0
66.9
91.0
93.5
FutureCom F
0.79 x c
Propagation velocity
20
8.1
7.3
80.0
77.0
98.0
68.0
93.0
65.0
91.0
92.7
31.25
62.5
80.0
75.1
10.1
9.2
>100.0
77.0
98.0
64.1
90.0
61.1
88.0
90.8
14.5
13.2
<10 m V/m at 10 MHz
>20 dB at 100 MHz
Unbalance to ground
Delay skew
100 V +/- 25%
>40 dB at 1 MHz
Unbalance to ground
2.0
1.7
125 V +/- 20%
Impedance Zo at 101 - 250 MHz
Attenuation in dB/100m*
Typical values dB/100m
>5000 MV x km
Insulation resistance
Surface transfer impedance
damp rooms
Temperature range (installation)
Electrical Characteristics (at 20°C)
Impedance Zo at 251 - 600 MHz
Dry and
100 m
4.2 ns/m
100
4 ns/100 m
18.5
16.8
72.4
>100.0 >100.0
72.5
69.4
98.0
98.0
55.1
51.0
58.1
86.0
84.0
86.8
FutureCom 10TEN
Halogen free
0.8
10 Gbit/s
FutureCom E
Conductor insulation
600 m
1 Gbit/s
FutureCom D
Mechanical Characteristics
0.7
1300 nm
FutureCom UD FutureCom UE
2.5
2.7
850 nm
1300 nm
54.0
83.0
81.0
83.2
300
600
65.3
60.8
33.3
30.0
96.0
62.3
94.0
44.5
68.0
41.5
66.0
66.0
48.9
42.5
92.0
57.8
90.0
38.4
51.0
35.4
49.0
49.5
800
53.0
–
87.0
–
85.0
–
–
–
–
34.0
WCXWXW-X0087-C001-L6
–
*Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
Type designation
J-VH 4G50L/125 +
S/FTP 600/23 FRNC
Pair/fiber
Category count
7
4/4
Max
Outer [ Weight Length
Tensile
Fire Load Zero
Order Number
(MJ/m) Halogen Strength (N)(mm) (kg/km) (m)
1.44
Yes
154
7.5x15.5 110
Corning Cable Systems
500
Special
Cable
Ordering Information
Hardware
InfiniCor® OM2 (50 µm)
850 nm
Guaranteed minimum distance at
Industrial
Cable
Features
Typ. attenuation
in the tight buffer
cable in dB/km
Further
Information
Fiber Type
Typ. attenuation
Loose Tube
Cables
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Fiber Specification - Laser-Optimized InfiniCor® Multimode Fibers
Introduction
FutureCom™ Hybrid Cable
S/FTP 600/23 4P + J-VH 4G50 FRNC
197
FutureCom™ ViMF Cat.6 Cable (Star Quad)
S/FTP 600/22 FRNC
Application
The FutureCom™ StarQuad ViMF Cable is designed for
applications in industrial and other harsh environments up
Braided shield
Halogen-free jacket,
flame retardant
Foil shielding
1 twisted quad
PE foam-skin insulation
Copper conductor
AWG 22
PP foil
Mechanical Characteristics
Conductor insulation
Outer jacket
Area/range of application
Temperature range (installation)
Operating temperature
Halogen free
foam-skin material
Halogen free
flame retardant
Dry and
damp rooms
skew between the individual pairs of foursomes is very low.
This is increasingly required for applications above 1 Gigabit
Ethernet. The cable has a streamlined construction and low
weight.
StarQuad ViMF Cables are intended for multimedia applications (voice, image and data communications) where cable
sharing is an option. Alongside traditional applications
(ISDN, Ethernet and Token Ring), the cables are suitable for
systems with high frequency areas, such as TPDDI via copper
S/FTP 600/22 cable, specified up to 600 MHz
Outstanding electrical characteristics
Each StarQuad (foursome) is shielded (ViMF)
Different color coding of individual foursomes
Simultaneous, standard-conforming transmission
of multiple services is possible
Very robust, thus particularly suitable for application in
-5 to +50°C
industrial and other harsh environments
(over flat side*)
Halogen-free (LSZH)
-20 to +60°C
(over flat side*)
198
FutureCom ViMF Cables are zero-skew products, i.e. the
Features
installation
Copper conductor
EN 50173-1 (2003).
1000 Base-T.
>_ 26 mm
Min. bending radius during
6 specifications according to ISO/IEC 11801 (2002) and
(TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to
Min. bending radius
for one-time bending
to 600 MHz. Its transmission characteristics satisfy Category
>_ 40 mm
AWG 22
Full copper braid shield
Zero skew between the foursomes
Flame retardant according to IEC 60332-3, Category C
Non-corrosive according to IEC 60754-2 (FRNC)
Low smoke according to IEC 61034
Corning Cable Systems
FutureCom™ ViMF Cat.6 Cable (Star Quad)
S/FTP 600/22 FRNC
100 V +/- 15%
FutureCom F
125 V +/- 20%
<10 m V/m at 10 MHz
Surface transfer impedance
dB/BZL = 1000 m
FutureCom 10TEN
>46 dB at 64 kHz
Unbalance to ground
>40 dB at 1 MHz
Unbalance to ground
dB/BZL = 100 m
Greatest possible loop resistance 130 V/km
FutureCom E
48 pF/m
Operating capacity
0.74 x c
Propagation velocity
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
4.9 ns/m
FutureCom D
0 ns/100 m
Delay skew
1
Frequency in MHz
10
16
20
31.25
62.5
100
250
Attenuation in dB/100 m *
2.1
6.0
7.6
8.5
10.8
15.5
19.9
33.0
Typical values in dB at 100 m (pair/pair)
78.6
67.5
64.0
62.0
59.0
54.5
51.8
45.0
Typical values dB/100m
1.5
NEXT in dB at 100 m *
66.0
Typical values in dB at 100 m (foursome/foursome)
90.0
PSNEXT in dB at 100 m *
64.0
Typical values in dB at 100m
75.6
ELFEXT in dB at 100 m *
66.0
Typical values in dB at 100m
75.0
PSELFEXT in dB at 100m *
64.0
Typical values in dB at 100m
73.0
ACR in dB
77.1
4.9
59.3
90.0
57.3
64.5
50.0
65.0
47.0
63.0
62.6
6.3
56.2
90.0
54.2
61.0
45.9
62.0
43.0
60.0
57.7
7.1
54.8
90.0
52.8
59.0
44.0
60.0
41.0
58.0
54.9
9.0
51.9
90.0
49.9
56.0
40.1
54.0
37.1
52.0
50.0
12.9
47.4
90.0
45.4
51.5
34.1
44.0
31.1
42.0
41.6
16.5
44.3
90.0
42.3
48.8
30.0
36.0
27.0
34.0
35.3
26.9
38.3
75.0
36.3
42.0
22.0
17.0
19.0
15.0
18.1
600
43.6
–
38.0
–
70.0
35.0
–
–
–
–
–
* Standard: Requirements for 100 m installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1)
Industrial
Cable
–
Ordering Information
S/FTP 600/22 ViMF 6
2
0.89
Yes
179
5.2x8.3 75
Corning Cable Systems
1000
Special
Cable
Type designation
Max
Outer [ Weight Length
Tensile
Fire Load Zero
Category Quad count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m)
Order Number
CCXSCD-F0027-C001-L7
199
Further
Information
Impedance Zo at 0.064 MHz
FutureCom UD FutureCom UE
Impedance Zo at 1 - 100 MHz
>5000 MV x km
Insulation resistance
Hardware
1%
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Largest resistance margin
Introduction
Electrical Characteristics (at 20°C)
FutureCom™ ViMF Cat. 5 Cable (Star Quad)
U/FTP 300/23 FRNC
Foil shielding
Halogen-free
jacket
Foil shielding
1 twisted
quad
Additional
wire
PE insulation
Copper
conductor
AWG 23
PP foil
Application
The FutureCom™ StarQuad ViMF Cable is designed for
applications in industrial and other harsh environments up
to 300 MHz and its transmission characteristics satisfy
Category 5 specifications according to ISO/IEC 11801 (2002)
and EN 50173-1 (2003).
FutureCom ViMF Cables are zero-skew products. i.e. the
skew between the individual pairs of foursomes is very low.
This is increasingly required for Gigabit-Ethernet.
StarQuad ViMF Cables are intended for multimedia applications (voice, image and data communications) where cable
sharing is an option. Alongside traditional applications
(ISDN, Ethernet and Token Ring), the cables are suitable for
high frequency transmission, such as TPDDI via copper
(TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to
1000 Base-T.
Features
U/FTP 300/23 cable, specified up to 300 MHz
Outstanding electrical characteristics
Each StarQuad (foursome) is shielded (ViMF)
Simultaneous, standard-conforming transmission
of multiple services is possible
Very robust, thus particularly suitable for application in
industrial and other harsh environments
Full shielding including one PP foil and 2 aluminum-clad
foils
Zero skew between the foursomes
Halogen-free (LSZH)
Flame retardant according to IEC 60332-3, Category C
Non-corrosive according to IEC 60754-2 (FRNC)
Low smoke according to IEC 61034
Available in 2, 3, 4 and 7 foursomes
200
Corning Cable Systems
FutureCom™ ViMF Cat. 5 Cable (Star Quad)
U/FTP 300/23 FRNC
Temperature range (installation)
Operating temperature
Min. bending radius
for one-time bending
damp rooms
0 to +50°C
-20 to +60°C
2V: >_ 30 mm (flat side)
3V: >_ 50 mm
4V: >_ 52 mm
7V: >_ 65 mm
Min. bending radius during
2V: >_ 45 mm (flat side)
3V: >_ 75 mm
installation
4V: >_ 78 mm
7V: >_ 100 mm
Copper conductor
AWG 23
1
Frequency in MHz
dB/BZL = 1000 m
Unbalance to ground
dB/BZL = 100 m
Greatest possible loop resistance
Operating capacity
Propagation velocity
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
16
20
31.25
>40 dB at 1 MHz
130 V/km
48 pF/m
0.68 x c
4.9 ns/m
0 ns/100 m
Delay skew
10
62.5
100
Attenuation in dB/100 m *
2.1
6.3
8.0
9.0
11.4
16.5
21.3
Typical values in dB at 100 m (pair/pair)
80.0
64.0
61.0
60.0
56.0
50.5
47.0
Typical values dB/100m
1.8
NEXT in dB at 100 m *
65.3
Typical values in dB at 100 m (foursome/foursome)
90.0
PSNEXT in dB at 100 m *
62.3
Typical values in dB at 100m
76.7
ELFEXT in dB at 100 m according *
63.8
Typical values in dB at 100m
75.0
PSELFEXT in dB at 100m according *
60.8
Typical values in dB at 100m
73.0
ACR in dB
78.2
5.2
50.3
90.0
47.3
61.1
43.8
64.0
40.8
62.0
58.8
6.7
47.2
90.0
44.2
57.8
39.7
61.0
36.7
59.0
54.3
7.5
45.8
90.0
42.8
56.9
37.8
59.0
34.8
57.0
52.5
9.4
42.9
90.0
39.9
52.8
33.9
53.0
30.9
51.0
46.6
Introduction
<10 m V/m at 10 MHz
>46 dB at 64 kHz
Unbalance to ground
13.7
38.4
90.0
35.4
47.5
27.9
47.0
24.9
45.0
36.8
17.6
35.3
90.0
32.3
44.0
23.8
43.0
20.8
41.0
29.4
200
300
41.0
38.3
25.1
–
–
80.0
38.0
–
32.0
–
30.0
–
15.9
30.9
–
80.0
35.3
–
22.0
–
20.0
–
7.4
*Standard: Requirements for 100 m installed Category 5 cable for Class D cabling sections (conforms with EN 50288-2-1)
Type designation
U/FTP 300/23 3V
5
U/FTP 300/23 2V
U/FTP 300/23 4V
U/FTP 300/23 7V
5
2
0.89
Yes
110
5.6x9.6 79
5
7
3.28
Yes
390
13.2
5
3
4
1.71
1.95
Yes
Yes
165
220
10.1
10.4
Corning Cable Systems
105
125
219
Industrial
Cable
Ordering Information
Max
Outer [ Weight Length
Tensile
Fire Load Zero
Category Quad count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m)
Order Number
1000
CCXSDC-C0022-C001-L7
1000
CCXSDC-C0072-C001-L7
500
500
FutureCom F
Dry and
100 V +/- 15%
Surface transfer impedance
FutureCom 10TEN
Area/range of application
Impedance Zo at 1 - 100 MHz
FutureCom E
flame retardant
125 V +/- 20%
Impedance Zo at 0.064 MHz
FutureCom D
Halogen free
>5000 MV x km
Insulation resistance
FutureCom UD FutureCom UE
Outer jacket
2%
Hardware
foam-skin material
Largest resistance margin
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Halogen free
CCXSDC-C0032-C001-L6
CCXSDC-C0042-C001-L6
201
Special
Cable
Conductor insulation
Electrical Characteristics (at 20°C)
Further
Information
Mechanical Characteristics
FutureCom™ ViMF Cat. 5 Cable (Star Quad)
U/FTP 300/23 PVC
Foil shielding
Schirmfolie
PVC jacket
Mantel
PVC
Foil shielding
Schirmfolie
Additional wire
Beidraht
twisted
quad
41 Adern
zum
Vierer verseilt
PE insulation
PE-Isolierung
Copper conductor
AWG 23
Kupferleiter
AWG 23
PP foil
Application
The FutureCom™ StarQuad ViMF cable is designed for
applications in industrial and other harsh environments up
to 300 MHz and its transmission characteristics satisfy
Category 5 specifications according to ISO/IEC 11801 (2002)
and EN 50173-1 (2003).
FutureCom ViMF cables are zero-skew products, i.e. the skew
between the individual pairs of foursomes is very low. This is
increasingly required for Gigabit-Ethernet.
StarQuad ViMF cables are intended for multimedia applications (voice, image and data communications) where cable
sharing is an option. Alongside traditional applications
(ISDN, Ethernet and Token Ring), the cables are suitable for
high frequency transmissions, such as TPDDI via copper
(TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to
1000 Base-T.
Features
U/FTP 300/23 cable, specified up to 300 MHz
Outstanding electrical characteristics
Each StarQuad (foursome) is shielded (ViMF)
Simultaneous, standard-conforming transmission
of multiple services is possible
Very robust, thus particularly suitable for application in
industrial and other harsh environments suitable
Full shielding including one PP foil and 2 aluminum-clad
foils
Zero skew between the foursomes
PVC jacket
Flame retardant according to IEC 60332-1, Category B
Available in 1, 2, 3, and 4 foursomes
202
Corning Cable Systems
Temperature range (installation)
Operating temperature
Min. bending radius
for one-time bending
damp rooms
-20 to +60°C
1V: >_ 30 mm
3V: >_ 50 mm
4V: >_ 52 mm
1V: >_ 45 mm
installation
2V: >_ 45 mm (flat side)
3V: >_ 75 mm
4V: >_ 78 mm
Copper conductor
>46 dB at 64 kHz
<10 m V/m at 10 MHz
dB/BZL = 1000 m
0 to +50°C
2V: >_ 30 mm (flat side)
Min. bending radius during
Unbalance to ground
AWG 23
1
Frequency in MHz
Unbalance to ground
dB/BZL = 100 m
Greatest possible loop resistance
Operating capacity
Propagation velocity
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz
16
20
31.25
130 V/km
48 pF/m
0.68 x c
4.9 ns/m
0 ns/100 m
Delay skew
10
>40 dB at 1 MHz
62.5
100
Attenuation in dB/100 m *
2.1
6.3
8.0
9.0
11.4
16.5
21.3
Typical values in dB at 100 m (pair/pair)
80.0
64.0
61.0
60.0
56.0
50.5
47.0
Typical values dB/100m
1.8
NEXT in dB at 100 m *
65.3
Typical values in dB at 100 m (foursome/foursome)
90.0
PSNEXT in dB at 100 m *
62.3
Typical values in dB at 100m
76.7
ELFEXT in dB at 100 m *
63.8
Typical values in dB at 100m
75.0
PSELFEXT in dB at 100m *
60.8
Typical values in dB at 100m
73.0
ACR in dB
78.2
5.2
50.3
90.0
47.3
61.1
43.8
64.0
40.8
62.0
58.8
6.7
47.2
90.0
44.2
57.8
39.7
61.0
36.7
59.0
54.3
7.5
45.8
90.0
42.8
56.9
37.8
59.0
34.8
57.0
52.5
9.4
42.9
90.0
39.9
52.8
33.9
53.0
30.9
51.0
46.6
13.7
38.4
90.0
35.4
47.5
27.9
47.0
24.9
45.0
36.8
17.6
35.3
90.0
32.3
44.0
23.8
43.0
20.8
41.0
29.4
200
25.1
–
41.0
–
80.0
38.0
–
32.0
–
30.0
–
15.9
300
30.9
–
38.3
–
80.0
35.3
–
22.0
–
20.0
–
7.4
*Standard: Requirements for 100 m installed Category 5 cable for Class D cabling sections (conforms with EN 50288-2-1)
Type designation
U/FTP 300/23 2V
5
U/FTP 300/23 1V
U/FTP 300/23 3V
U/FTP 300/23 4V
Industrial
Cable
Ordering Information
Std.
Max
Outer [ Weight Length
Tensile
Fire Load Zero
Category Quad count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m)
Order Number
5
1
0.65
No
55
5.5
39
1000
CCXSKC-C0012-C001-L7
5
4
2.00
No
220
10.4
125
500
CCXSKC-C0042-C001-L6
5
2
3
1.23
1.71
No
No
110
165
5.5x9.4 76
10.1
Corning Cable Systems
105
1000
500
FutureCom F
Dry and
Surface transfer impedance
FutureCom 10TEN
Area/range of application
100 V +/- 15%
Impedance Zo at 1 - 100 MHz
FutureCom E
flame retardant
125 V +/- 20%
FutureCom D
Halogen free
Impedance Zo at 0.064 MHz
FutureCom UD FutureCom UE
Outer jacket
> 5000 MV x km
Insulation resistance
Hardware
foam-skin material
2%
Largest resistance margin
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Halogen free
CCXSKC-C0022-C001-L7
CCXSKC-C0032-C001-L6
203
Special
Cable
Conductor insulation
Electrical Characteristics (at 20°C)
Further
Information
Mechanical Characteristics
Introduction
FutureCom™ ViMF Cat. 5 Cable (Star Quad)
U/FTP 300/23 PVC
204
Corning Cable Systems
Further
Information
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
13 Further Information
13.1. Training
206
13.2. EWP
13.3. Glossary
209
13.4. Type Codes
13.5. Product Index
211
212
Corning Cable Systems
205
FutureCom F
Introduction
207
FutureCom 10TEN
Table of contents
LANscape® Training
Training: Expertise for Your Employees
Total communication solutions are becoming increasingly
important for communication networks, in particular local
area networks (LANs) because the future lies in the convergence of voice, video and data. Around the globe, as infor-
mation infrastructures evolve, so the demands on the quality of networked communication solutions continue to
grow. Meeting these demands calls for knowledge - knowledge that we can pass on to you.
Techniques and products are subject to constant change.
This makes it essential to have highly trained employees
who know how to exploit technical progress to your advantage. This can only be achieved with continuous training.
As a leading provider of communication cables, hardware
and services, we are working with our customers to build
communication highways for the future. We realize that the
planning, installation and maintenance of cable systems
calls for comprehensive technical knowledge - something
we want to share with you in spirit of genuine partnership.
For more Information about LANscape® Training:
On the Internet:
http://www.corning.com/cablesystems
We Train – You Benefit
Our worldwide knowledge in cable and network technology
is channeled to our Training Center. It is from this knowledge
base that we develop a wide range of seminars for your employees. Our training is aimed at all organizations involved
in constructing or operating cable systems in the private
networks or carrier area. By undertaking training before
starting on a project, you can avoid costly installation errors,
and take a decisive step towards ensuring a successful outcome to your project.
Practical Orientation – Not Just Theory
The balance between the two is critical: theory is necessary,
but practice dictates what is done. From many years of practical experience, our trainers know which knowledge and
skills are required for each task, and they are in constant
contact with development, sales and project engineering
teams at Corning Cable Systems.
Our Training Centers are located in Berlin and Neustadt /
Coburg, Germany. Standard and customized courses to meet
Or via E-Mail:
individual requirements are held locally throughout the
world, where the technical facilities permit.
emea.cs@corning.com
Or by phone under:
Freephone: 00800 2676 4641
Detailed training information is available on request.
Course Portfolio Private Networks:
LANscape® Certified Approved Installer Courses for
Structured Premises Cabling
LANscape® Copper Approved Installer
LANscape® Copper Approved Installer – Refresher
LANscape® Fiber Optic Approved Installer
LANscape® Fiber Optic Approved Installer - Refresher
206
Corning Cable Systems
LANscape® Cabling Solutions:
A Name You Can Trust
Introduction
Meeting and Exceeding
Global Standards
We guarantee that each customized Corning Cable Systems
LANscape® Cabling Solution meets or exceeds the global
FutureCom F
data communication and performance standards. You can
and trained.
Each partner-company meets our stringent requirements for
technical experience, financial strength and proven dedication to quality. EWP partners must demonstrate ongoing
products withstand rigorous field and laboratory testing
with continual design enhancements in response to rapidly
evolving customer environments.
Ready for Your Growing Network
Corning Cable Systems understands the critical need for
flexible solutions with the rapid growth of your data
communications requirements. With Corning Cable Systems’
LANscape® Solutions, changes and expansions are cost-
effective and simple. Your cost-of-ownership is minimized!
Expert Service and Support
Corning Cable Systems’ experts support and assist Extended
Warranty Program installers with the planning, designing,
and installing of fiber optic and high-end copper cabling systems.. With world-wide distribution channels and a high
class Customer Service Center, Corning Cable Systems makes
it easy for EWP installers to quickly get products to your site
for installation. Highly trained sales consultants located in
your area are available for on-site evaluations and cabling
recommendations.
Special
Cable
update training at least once every two years.
systems to the customer. Corning Cable Systems LANscape®
Further
Information
commitment to extensive training and are required to
The LANscape® end to end product offering is designed to
FutureCom E
deliver the most technologically advanced communications
Corning Cable Systems’ network of LANscape® Extended
FutureCom D
Warranty Program™ (EWP) installers are carefully selected
FutureCom UD FutureCom UE
LANscape® Solutions Total Package
Hardware
Installation Expertise and Reliability
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
ISO/IEC 11801 and EN 50173 (Europe).
Industrial
Cable
ures up to the international cabling requirements,
FutureCom 10TEN
be assured that your Corning Cable Systems Solution meas-
Corning Cable Systems
207
LANscape® Solutions:
A Name You Can Trust
Extended Warranty – Extra Value
Corning Cable Systems’ LANscape® Extended Warranty
protects your LANscape Fiber Optic and/or High-end Copper
Solution for a full 25 years*. The warranty covers total sys-
tem performance as well as each product component of the
Corning Cable Systems’ solution. Corning Cable Systems
Total Corporate Assurance
EWP 25-year system warranty is offered when all products in
rily on fiber cabling solutions while also offering high-end
guarantees to repair or replace defective products for 25
years after installation by an EWP Partner. The LANscape®
the cabling solution (cables, connectivity, and interconnect-
ing hardware) are Corning Cable Systems products installed
by an EWP Partner.
Corning Cable Systems is the only company focusing primacopper solutions. Our mission is to remain the world’s
leading developer and manufacturer of fiber optic and
high-end copper products for voice, data, and video applications. Corning Cable Systems’ resources for research and
product development, financial strength, and mature
business focus are clearly unmatched in the communications industry.
Corning is the inventor of the first commercial optical fibers
and the world leader in optical fiber manufacturing for over
25 years. Our unique heritage makes Corning Cable Systems
the one company that can offer a solid corporate foundation, a tradition of quality, and a name you can trust.
How You Benefit
LANscape® 25 years warranty
Installation by Corning Cable Systems
Approved partners
Partners trained on the latest technology
Corning Cable Systems total quality
*The Extended Warranty of Corning Cable Systems is subject to the terms and conditions set forth in the EWP Contract to be signed by each EWP Partner and set
forth in the Warranty Statement granted to the endcustomer of an installation. The liability of Corning Cable Systems for failures /malfunction or alterations of
the specifications published at the date of installation is repair or replacement of the defective product. Corning Cable Systems shall not be liable for any consequential damages or violation of the contract terms with respect to the warranty obligation for this product. The maximum liability of Corning Cable Systems
within the scope of the Extended Warranty Program is repair and replacement of the Corning Cable Systems product that does not comply with the Corning Cable Systems specifications published at the date of installation of such product plus labor costs in connection with the replacement or the repair of such products
amounting to a maximum of Euro 10.000 (ten thousand).
208
Corning Cable Systems
Cable sheath
Capacitance unbalance
Characteristic impedance
Conductor
Conductor resistance
Corrosive
DC loop resistance
Delay skew
Dielectric
ELFEXT
FEXT
Fire rating
Flame retardant
Frequency
FRNC
Impedance
Insulation resistance
packets of fixed size. ATM supports data transfer rates of from 25 to 622 Mbps (megabits per
second).
American designation for conductor diameter (American Wire Gauge)
The totality of cabling elements in the cable and the wrapping covering all these elements.
Covering, generally of polyethylene (PE), polyvinylchloride (PVC) or zero-halogen material (H),
to protect the cable core against environmental influences.
The difference between the ground capacitances of the two conductors.
Complex quantity defining the ratio of voltages to currents in a propagating wave at every
point along the line.
The conductor is used for transporting the electrical charge carriers and is therefore made of
electrically conducting material (metal). The conductor is usually round.
Conductor resistance is determined by the quality of the copper used and the cross-section of
the conductor. It increases linearly with cable length and has a determining influence on the
attenuation.
Release of corrosive gases and acids by the combustion of cables and lines. For indoor installations, non-corrosive cables should be used. Halogen-free cables are generally non corrosive.
Overall DC resistance of the go and return conductors (unit: ?/km)
The difference in time between the arrival (reception) of a data signal and subsequent related
data signals. Usually expressed in nanoseconds.
Insulating material, also termed dielectric medium, i.e. an electrically non-conducting material
A measurement of the unwanted signal coupling from a transmitter at the near end into another pair, measured at the far end with the effects of the attenuation removed.
Far-end crosstalk loss is the attenuation between the transmission circuits of a cable at the
different ends of the cable.
Sum of the combustion heat of all the combustible materials located in a room (unit for cables:
MJ/m)
Description of the behavior of products with respect to fire propagation. Enhanced flame
retardancy is generally required only for indoor cables.
Number of complete cycles per second (in Hz).
Flame retardant (FR) and non corrosive (NC)
Impedance of an electrical four-terminal network. It comprises the DC resistance and the
reactance, the latter being the frequency-dependent opposition to current flow offered by
inductances and capacitances. Impedance is physically determined by the dimensions of inner
conductor, dielectric and shield.
This is determined by the insulating material and more particularly by the nature of the
insulant than by its thickness. The insulation resistance is length dependent.
Corning Cable Systems
FutureCom F
FutureCom 10TEN
Asynchronous Transfer Mode is a network technology based on transferring data in cells or
FutureCom E
Cable core
cable in the stationary condition (unit: dB/km or dB/100m).
FutureCom D
AWG
Known also as attenuation coefficient, it is the length related attenuation introduced by the
FutureCom UD FutureCom UE
ATM
frequency dependent and caused mainly by resistance and the skin effect (unit: dB)
Further
Information
Attenuation constant
Hardware
Reduction in electrical signal power between two defined points on a transmission path. It is
cable.
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Attenuation
Crosstalk noise from other cables in a bundle of cables or from a second cable unit in a duplex
Industrial
Cable
Attenuation-to-crosstalk ratio
ANEXT
Special
Cable
ACR
Introduction
Glossary
209
Glossary
LAN: Local Area Network
Length of lay
LS0H/LSZH
Mutual capacitance
NEXT
Propagation delay
Propagation velocity
PS-ACR
PSANEXT
PSELFEXT
PSNEXT
Quad
Resistance unbalance
Return loss
Shield
Shielding
Skew
Skin effect
Smoke density
Transfer impedance
Twisted pair
Wire
210
Local network for bit-serial transmission between interconnected, independent terminal
equipments. The term LAN was introduced in order to distinguish this network from processor
links (central processor unit with peripherals) operating at very high bit rates over short
distances on the one hand and from publicly accessible networks operating over long
distances on the other.
The distance along the center axis of a cable that a cabling element advances in order to
complete one full turn (360°) about this axis.
Low smoke (LS) and zero halogen (0H)
Effective capacitance of the line
Near-end crosstalk loss is the attenuation between the transmission circuits of a cable at the
same end of the cable.
The time required for a signal to pass along a transmission line.
The velocity of wave propagation along a transmission line.
The difference between attenuation and PSNEXT. The result is referred to as “head room”. The
more head room a cable or system has the more forgiving it will be with the installation errors
(apart from mis-wiring).
Sum of the unwanted signal coupling of crosstalk noise at the near end from external cabling
pairs into an affected pair of cable.
A computed sum value of the individual ELFEXT effects on each pair by the other 3 pairs.
ELFEXT removes the impact of insertion loss on Far End Crosstalk.
The sum of all pair combinations for crosstalk as it occurs when a signal is introduced into a
communications cable, and measured at the near end to the transmitter
A series of four separately insulated conductors, generally twisted together.
Difference in DC resistance between two wires of a circuit (unit: ?)
The difference between the power incident upon a discontinuity in a transmission system and
the power reflected from the discontinuity.
Structural cable element for shielding. The design of the shield depends on whether one is
seeking protection against electric fields (capacitive coupling) or magnetic fields (inductive
coupling) or against both. Shielding materials against magnetic fields should always have a
high electrical conductivity and small inductance, which is why, in the case of conductors,
copper is mostly used.
Protects against electric and magnetic influence caused by emission (emitted interference)
and emission (received interference).
A measure of the inequality of propagation delay between two pairs in a multi-pair cable
Tendency for higher frequency currents to travel near the outside surface of a conductor
Measure of the smoke generated by a burning cable. For indoor installation, cables should be
selected with a low smoke density (typical value: 50%).
Surface transfer impedance is a measure of the effectiveness of the shielding and is defined as
the ratio of the voltage along the shield of the disturbed system to the current in the
disturbing system.
A transmission line in which two insulated conductors are twisted together.
The wire is a conductor with a surrounding insulant. The insulant can be air or other
electrically non-conducting material (usually plastic).
Corning Cable Systems
Further
Information
Special
Cable
Industrial
Cable
Flex Wire Cable Telephone /
for Patch Cord ISDN Products
Hardware
FutureCom UD FutureCom UE
FutureCom D
FutureCom E
FutureCom 10TEN
FutureCom F
Introduction
Type Codes for Copper Cables
Corning Cable Systems
211