Philips Lumec HighFocus
Transcription
Philips Lumec HighFocus
Roadway HighFocus Above all, maximizing efficiencies with light Low-maintenance LED high mast solution Elevate your freedom You already know that LED technologies can significantly reduce energy usage and lightingrelated energy costs. But, did you know that the right LED high mast luminaire can also be a low-maintenance solution that reduces labor and maintenance time, too? Introducing Philips Lumec HighFocus LED high mast luminaires – the high-performing, low-maintenance high mast solution that provides managers and work crews with the freedom to focus on other tasks. 2 Philips Lumec HighFocus LED high mast luminaires help to reduce lighting-related energy costs compared to HID technologies while meeting or exceeding code requirements, and their long life, backed by industry leading 10-year limited warranty and Luminaire Useful Life rating, means that maintenance time and related costs are also reduced. Additionally, with among the highest lumen output in the market today, as much as 50% higher than other leading brands, you may be able to significantly reduce the number of luminaires on each pole without compromising on light quality or a sense of security for those in the area. HighFocus Roadway Intro The savings - money and time - really add up with HighFocus 3 Your crews spend less time on maintenance and repair Luminaire Useful Life vs. Lumen maintenance Not all high mast luminaires are built to the same standards. Some manufacturers base their rated life on a small portion of the overall luminaire – only the LED lumen maintenance data. HighFocus luminaires measure LED lumen maintenance as well as LED life, driver life, on/off cycles, burn 4 Philips Lumec hours, corrosion considerations, light engine PCB substrate, solder joints and more. This provides confidence that the entire HighFocus luminaire will consistently perform today and far into the future with extended lumen maintenance and fewer trips needed for luminaire service. HighFocus Roadway Savings More time for more savings Whether you’re looking to install a complete high mast system, or replacing luminaires in an existing high mast system, HighFocus can help you to save operational and maintenance costs. With up to 103 LPW, and 31,223-97,389 delivered lumens, it is possible to reduce the overall number of luminaires needed per high mast setup when compared to traditional HID technologies, thereby further reducing energy-related costs and initial project costs. The long life of HighFocus, backed by a 10-year limited warranty, means that your crews aren’t burdened by endless and labor-intensive re-lamping cycles. All of this, and our exclusive Luminaire Useful Life rating, combine to provide payback periods of 2.7 years, as shown in the figure below. Contact us directly to learn how connected lighting options can help to further optimize lighting-related energy expenses, further reduce payback periods, and provide valuable insight into the lighting infrastructure’s health and operation. 58% Annual energy savings over HID 1 8,064 Metric tons of CO2 eliminated annually 2 This is an ROI example you can achieve by retrofiting 4,000 HID luminaires with 2,000 HighFocus LED high mast luminaires. 2.7 1. B ased on comparison between 1000W HPS luminaires (at 1150W) and HFL-276L1050NW-G1 (at 965W) with an energy rate of $0.1045/KWh. National average energy rates and other assumptions apply. Contact Philips for more details and to help you determine your savings. 2. Conversion factors for CO2 calculations courtesy of the U.S. Environmental Protection Agency (U.S. EPA). 3. B ased on national average energy rate and other assumptions. Your specific case may vary. Contact Philips for more details and to help you determine your savings. Payback in years 3 5 Project a guiding light 6 Philips Lumec HighFocus Roadway Reliability Motorists aren’t inconvenienced by frequent servicing HighFocus benefits also extend to those using the space while helping you to project a sustainable image. The long LED life means that drivers and others within the space aren’t frequently inconvenienced by maintenance-related lane or area closures. Consistent and uniform light levels, from HighFocus’s specially-designed discrete LED optics mean that anyone can confidently navigate the well-lit area with ease. 7 Scalable solutions for local challenges HighFocus LED luminaires are scalable, so you can customize your high mast solution to maximize your energy saving benefits. They provide reliable and uniform LED illumination ranging from 400 to 1000W HID replacement, while exceeding the performance of traditional lighting technologies. •Three lumen packages available providing up to 97,389 lumens •Precision optics direct more lighting to the roadway •Superior uniformity enhances visibility •No uplight (U0 rating) 8 Philips Lumec HighFocus Roadway With fewer luminaires to maintain, you have even more time Performance Freeway Luminaire Qty: 4 Distribution: Type II (2) Cloverleaf Luminaire Qty: 5 Distribution: Type V (5M) Switching your HID high mast luminaires to HighFocus LED not only saves energy and operating costs, it allows you to achieve comparable photometric performance while cutting your luminaire quantity in half.* This means you have fewer luminaires to maintain, allowing you to do more with less by simply switching to HighFocus. Note: The luminaires and optical distributions shown are examples. Confirm which HighFocus is right for you using a photometric layout of your application. up to 50% Fewer luminaires* than existing HID *B ased on photometric comparison of (8) 400W HPS Type 2 luminaires versus (4) HFL-184L1050NW-G1 and (10) 400W HPS Type 5 luminaires versus (5) HFL-184L1050NW-G1 HighFocus LED luminaires. 9 HighFocus high mast luminaires IP65 Rated compartment Dimming driver Surge protection Electrical compartment is IP65 sealed with pre-installed gasket to protect electrical components and terminal block against dust and moisture, increasing reliability and extending product life. Dimming driver (0-10V) is standard, enabling HighFocus to be combined with additional controls, now or in the future Standard SP1 and optional SP2 surge suppressors protect the luminaire Finish Black, Gray, White, Bronze Mounting IP66 Rated light engines Die-cast housing 2-3/8" O.D. (2" NPS) x 5-1/2" long tenon Reliable light engines are IP66 sealed to protect against dust and moisture so that LED life is extended Rugged, die-cast aluminum housing for maximum durability 10 Philips Lumec HighFocus Twist-lock receptacles Roadway Optional 5-pin and 7-pin NEMA twist lock receptacles available to facilitate connected lighting solutions that can quickly and easily be upgraded in the future Features Rotatable optics Entire optical assembly rotatable, enabling alignment of asymmetric optics parallel with roadway (as shown) to optimize optical performance. Bird guard High mast system Bird guard installed, seals around tenon, protects against birds and similar intruders Philips Lumec offers SkyMast raising and lowering device SMLS-G2 to accompany your HighFocus LED High Mast luminaires. Visit our eCatalog or contact your local sales representative for more information. LED Modules 2, 4, or 6 LED modules providing three different lumen packages 11 You can spend less time managing your high mast network Above and beyond Now, and in the future, a connected lighting system can improve your ways of working, helping to maximize energy and operational efficiencies. This type of scalable system provides remote monitoring, dimming and infrastructure status data in real time from a central location without requiring labor-intensive on-site assessments. Additionally, each individual luminaire may be assessed for granular management. illumination 12 Philips Lumec HighFocus Roadway Controls Controls City solutions Advanced. Powerful. Extensive. Widespread or multi-site lighting management with detailed asset management that can grow along with your needs. •AmpLight Group Cabinet Management •HighFocus LED High Mast luminaires will be shipped controls ready when you select either 5-pin or 7-pin receptacle option; 0-10V dimming driver is standard. Contact your local Sales Representative for more information and for help with putting together the entire system solution. For more information Visit us at www.philips.com/luminaires for more on Philips stand-alone and connected outdoor lighting solutions, and select Controls Outdoor, or request our outdoor lighting solutions brochure. Take the next step See how Philips Lumec HighFocus LED high mast luminaires can provide a complete solution for your roadway lighting needs. Contact your local Philips Sales Representative or visit www.philips.com/highfocus for more information or to schedule a personalized demonstration. 13 Ordering information Ordering guide Luminaire LED Module example: HFL-276L1050NW-G1-2-HVU-DD-TLRD5-HS-GY3 Optical System Voltage Driver and Dimming Twist-Lock Receptacle Surge Protection UNV 120-277VAC Standard: Standard: DD immable driver 0-10V D None (leave blank) Optional: Optional: Optional: AMPD 2 Amplight Dimming TLRD5 3,4 Receptacle for twist-lock photocell or shorting cap, 5-pin SP2 5 20kV / 20kA Surge Protector Luminaire Options Finish HS External house side shield BK Black finish HIS Internal house side shield, snap-on, 1 per LED light engine BR Bronze finish HFL HFL HighFocus 92L1050NW-G1 or 184L1050NW-G1 or 276L1050NW-G1 2 Type II 3 Type III 4 Type IV HVU 347-480VAC 5MType V Medium 120 6120V 5WType V Wide 208 6208V 1 240 6240V 277 277V 6 347 6347V 480 6480V 4 TLRD7 3,4 Receptacle for twist-lock photocell or shorting cap, 7-pin PH8 3,7 Twist-lock Photoelectric Cell, UNIV (120-277VAC) GY3 Gray finish WH White finish PH8/347 3,7 Twist-lock Photoelectric Cell, HVU (347VAC) PH8/480 3,7 Twist-lock Photoelectric Cell, HVU (480VAC) PHXL 3,7 Twist-lock Photoelectric Cell, extended life, UNIV (120-277VAC) PH9 3,7 Shorting cap F1 6 Fusing, single (120, 277 or 347VAC) F2 6 Fusing, double (208, 240 or 480VAC) F3 6 Fusing, Canadian double pull (208, 240 or 480VAC) 1.Please note these integrated features come standard with HighFocus luminaires. 2.Denotes programmable driver option. Not available with HVU (347-480VAC). 3.Use of photoelectric cell or shorting cap is required to ensure proper illumination. 4.HighFocus comes standard without a receptacle; to get a NEMA twist-lock receptacle, select either TLRD5 5-pin or TLRD7 7-pin option. 5.When SP2 option is selected you will get SP2 instead of standard SP1. 6.Specific voltage (120, 208, 240, 277, 347 or 480) must be specified with fusing options (F1, F2 or F3). 7.Includes TLRD5 unless TLRD7 is specified. Prior to ordering, consult specification sheets on philips.com/luminaires for the most current information, notes, and exclusions. Systems solutions HighFocus LED High Mast luminaires will be shipped controls ready when you select either 5-pin or 7-pin receptacle option; 0-10V dimming driver is standard. Contact your local Sales Representative for more information and for help with putting together the entire system solution. 14 Philips Lumec HighFocus 26-1/8'' 663mm 23'' 584mm Roadway Technical information 13-1/2'' 343mm Technical 21-1/4'' 540mm Dimensions Bottom view Side view 20 1/2'' 521mm 26-1/8'' 663mm 6-3/4'' 172mm Weight - 2 Module: 4 4 lbs 19.96 kg 23'' 584mm 14-1/4'' 362mm 5-1/8'' 130mm 13-1/2'' 343mm 21-1/4'' 540mm 4 Module: 6 0 lbs 27.22 kg 6 Module: 7 5 lbs 34.02 kg EPA - 1.89 sq. ft. 20 1/2'' 521mm 6-3/4'' 172mm Luminaire Options HIS HIS HIS HIS 14-1/4'' 362mm 5-1/8'' 130mm HISHIS HS HS HS HS PH8 PH8 HS PH8 HS PH8 Internal house side shield External house side shield F1 F2 F3 Single fuse Double fuse Canadian double pull fuse PH9 PH9 PH9 PH8PH8 SPC SPC SPCPH9 PH9 RC RC PHXL PH9 Photocell Photocell, extended life RC SPCSPC RC RC Shorting cap Optical distributions HighFocus offers many different optical distributions, providing the flexibility you need for all of your various roadway lighting needs. Plus, all optical distributions have a U0 rating which means no uplight - all of the lighting is directed downward on the roadway where it is needed. Type e II (2) Type II (2) Type II (2) Type II (2) II (2) Type Type III (3) Type III (3) Type III (3) Type III (3)III (3) Uplight Uplight Uplight Uplight aire Luminaire lumens Luminaire lumens Luminaire lumens Luminaire lumens lumens 37% 37% 37% 37% 28% 18% 28% 28% 28% 18% 18% 100 100 100 9% 100 9% 9% 90 90 90 90 90 80 80 80 80 80 60 30 Back 60 30 Back 60 30 0 Back 30 30 0Back 18% 3030 0 0 Front 37% Uplight Uplight Uplight Uplight Luminaire Luminaire lumens Luminaire lumens Luminaire lumens Luminaire lumens lumens 38% 38% 38% 38% 28% 28% 18% 100 9% 60 60 Uplight 19% 19% 100 100 100 9% 100 9% 9% 90 90 90 90 90 90 90 90 90 90 80 80 80 80 80 80 80 80 80 80 30 Front0 60 30 60 60 6060 60 30 30 30 FrontBack Front Back Front Back 60 30 0 Back 30 30 0Back 19% 3030 0 0 Front Type III (3) Type Type V (5M) Type V (5M) Type V (5M) Type V (5M) V (5M) 38% Uplight Uplight Uplight Uplight Luminaire Luminaire lumens Luminaire lumens Luminaire lumens Luminaire lumens lumens 35% 35% 35% 35% 28% 26% 19% 100 9% 60 60 Uplight 28% 100 60 Type II (2) 28% 100 100 1009% 19% 28% Type Type V (4) Type V (4) Type V (4) Type V (4)V (4) 26% 26% 18% 18% 100 100 100 100 100 100 9% 100 9% 9% 90 90 90 90 90 90 90 90 90 80 8080 80 80 80 80 80 80 80 1009% 60 30 Front0 60 30 18% 26% 60 60 30 6060 60 30 30 FrontBack Front Back Front Back 60 30 0 Back 30 30 0Back Type IV (4) 18% 3030 0 0 Front 35% Uplight Uplight Uplight Uplight Luminaire Luminaire lumens Luminaire lumens Luminaire lumens Luminaire lumens lumens 35% 35% 35% 35% 26% 26% 18% 100 9% 60 60 Uplight 26% 18% 18% 100 100 100 100 9% 100 9% 9% 90 90 90 90 90 90 90 90 90 90 80 80 80 80 80 80 80 80 80 80 60 30 Front0 60 30 60 60 6060 60 30 30 30 FrontBack Front Back Front Back 60 30 0 Back 30 30 0Back 18% 3030 0 0 Front 35% Uplight Uplight Uplight Uplight Luminaire Luminaire lumens Luminaire lumens Luminaire lumens Luminaire lumens lumens 35% 35% 35% 35% 26% 26% 18% 100 9% 60 60 Uplight 26% 100 100 1009% 18% 26% Type Type V (5W) Type V (5W) Type V (5W) Type V (5W) V (5W) 26% 35% 26% 26% 18% 18% 100 100 100 100 100 100 100 9% 100 9% 9% 90 90 90 90 90 90 90 90 90 90 90 90 80 80 80 80 80 80 80 80 80 80 80 80 1009% 60 30 Front0 Type V Medium (5M) 60 30 18% 26% Uplight 60 60 60 60 60 30 30 30 Front Back Front Back Front Back 60 30 0 Back 60 60 30 30 0Back 18% 1009% 60 3030 0 18% 100 9% 30 0 Front Type V Wide (5W) Note: The optical distributions shown are examples of the HFL-276L1050NW-G1. Consult HighFocus IES files for specific performance criteria. 15 Front0 100 60 30 Front 6 30 © 2016 Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. PLu-1508BR 04/16 philips.com/luminaires Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ 08873 Tel. 855-486-2216 Philips Lighting Canada Ltd. 281 Hillmount Rd, Markham, ON, Canada L6C 2S3 Tel. 800-668-9008 Project: Roadway Location: Cat.No: Type: HighFocus Lamps: Qty: Notes: Philips Lumec HighFocus LED high mast luminaires provide an energy saving, lowmaintenance solution that provides managers and work crews with the freedom to focus on other tasks. HighFocus LED features scalable lumen packages and offers up to 97,389 lumens. Ordering guide Luminaire LED Module example: HFL-276L1050NW-G1-2-HVU-DD-TLRD5-HS-GY3 Optical System Voltage Driver and Dimming Twist-Lock Receptacle UNV 120-277VAC Standard: Standard: DD immable driver 0-10V D None (leave blank) Surge Protection Luminaire Options Finish HS External house side shield BK Black finish HFL HFL HighFocus 92L1050NW-G1 or 184L1050NW-G1 or 276L1050NW-G1 2 Type II 3 Type III 4 Type IV HVU 347-480VAC 5MType V Medium 120 6120V 5WType V Wide 208 6208V 1 4 Optional: Optional: Optional: AMPD 2 Amplight Dimming TLRD5 3,4 Receptacle for twist-lock photocell or shorting cap, 5-pin SP2 5 20kV / 20kA Surge Protector 240 6240V 277 277V 6 347 6347V 480 6480V TLRD7 3,4 Receptacle for twist-lock photocell or shorting cap, 7-pin HIS Internal house side shield, snap-on, 1 per LED light engine PH8 3,7 Twist-lock Photoelectric Cell, UNIV (120-277VAC) BR Bronze finish GY3 Gray finish WH White finish PH8/347 3,7 Twist-lock Photoelectric Cell, HVU (347VAC) PH8/480 3,7 Twist-lock Photoelectric Cell, HVU (480VAC) PHXL 3,7 Twist-lock Photoelectric Cell, extended life, UNIV (120-277VAC) PH9 3,7 Shorting cap F1 6 Fusing, single (120, 277 or 347VAC) F2 6 Fusing, double (208, 240 or 480VAC) F3 6 Fusing, Canadian double pull (208, 240 or 480VAC) 1.Please note these integrated features come standard with HighFocus luminaires. 2.Denotes programmable driver option. Not available with HVU (347-480VAC). 3.Use of photoelectric cell or shorting cap is required to ensure proper illumination. 4.HighFocus comes standard without a receptacle; to get a NEMA twist-lock receptacle, select either TLRD5 5-pin or TLRD7 7-pin option. HFL_Spec 04/16 page 1 of 5 5.When SP2 option is selected you will get SP2 instead of standard SP1. 6.Specific voltage (120, 208, 240, 277, 347 or 480) must be specified with fusing options (F1, F2 or F3). 7.Includes TLRD5 unless TLRD7 is specified. HFL HighFocus High mast LED: 92, 184 and 276 LED Systems Solutions HighFocus LED high mast luminaires will be shipped controls ready when you select either 5-pin or 7-pin receptacle option; 0-10V dimming driver is standard. Contact your local Sales Representative for more information and for help with putting together the entire system solution. LED Wattage and Lumen Values LED CRI = 70, CCT = 4000K nominal (3710K to 4260K) System (LEDs + drivers) rated life = 100,000 hrs1 Typical Delivered Lumens LED Module Typical System Wattage (W)2 LED Current (mA) Typical System Current (A) @ 120V HFL-92L-1050-NW-G1-2 32,361 320 1050 2.96 HFL-92L-1050-NW-G1-3 32,406 320 1050 2.96 HFL-92L-1050-NW-G1-4 30,987 320 1050 2.96 HFL-92L-1050-NW-G1-5W 31,223 320 1050 2.96 HFL-92L-1050-NW-G1-5M 32,804 320 1050 2.96 HFL-184L-1050-NW-G1-2 64,232 640 1050 5.93 HFL-184L-1050-NW-G1-3 64,295 640 1050 5.93 HFL-184L-1050-NW-G1-4 61,470 640 1050 5.93 HFL-184L-1050-NW-G1-5W 61,964 640 1050 5.93 HFL-184L-1050-NW-G1-5M 65,244 640 1050 5.93 HFL-276L-1050-NW-G1-2 95,707 965 1050 8.94 HFL-276L-1050-NW-G1-3 93,942 965 1050 8.94 HFL-276L-1050-NW-G1-4 90,397 965 1050 8.94 HFL-276L-1050-NW-G1-5W 93,482 965 1050 8.94 HFL-276L-1050-NW-G1-5M 97,389 965 1050 8.94 26-1/8'' 663mm 1.L70 >100,000 hrs (at ambient temperature = 25°C). 23'' 584mm 2.System wattage or total luminaire wattage includes the LED module and the LED driver. 208V 240V 277V 347V 480V Efficacy (Lm/W) BUG Rating 1.71 1.71 1.71 1.71 1.71 3.42 3.42 3.42 3.42 3.42 5.15 5.15 5.15 5.15 5.15 1.48 1.48 1.48 1.48 1.48 2.96 2.96 2.96 2.96 2.96 4.47 4.47 4.47 4.47 4.47 1.28 1.28 1.28 1.28 1.28 2.57 2.57 2.57 2.57 2.57 3.87 3.87 3.87 3.87 3.87 1.02 1.02 1.02 1.02 1.02 2.05 2.05 2.05 2.05 2.05 3.09 3.09 3.09 3.09 3.09 0.74 0.74 0.74 0.74 0.74 1.48 1.48 1.48 1.48 1.48 2.23 2.23 2.23 2.23 2.23 101 101 97 98 103 100 100 96 97 102 99 97 94 97 101 B3-U0-G3 B3-U0-G4 B3-U0-G5 B5-U0-G4 B5-U0-G2 B5-U0-G5 B4-U0-G5 B4-U0-G5 B5-U0-G5 B5-U0-G2 B5-U0-G5 B5-U0-G5 B5-U0-G5 B5-U0-G5 B5-U0-G3 Note: D ue to rapid and continuous advances in LED technology, LED luminaire data is subject to change without notice and at the discretion of Philips. IES files with HS external house side shield and HIS internal house side shield options are also available – contact the factory. 13-1/2'' 343mm 21-1/4'' 540mm Dimensions Side View Bottom View 20 1/2'' 521mm 6-3/4'' 172mm 5-1/8'' 130mm 26-1/8'' 663mm Weight - 2 Module: 4 4 lbs 19.96 kg 23'' 584mm 14-1/4'' 362mm 13-1/2'' 343mm 21-1/4'' 540mm 4 Module: 6 0 lbs 27.22 kg 6 Module: 7 5 lbs 34.02 kg EPA - 1.89 sq. ft. 20 1/2'' 521mm 6-3/4'' 172mm 5-1/8'' 130mm HFL_Spec 04/16 page 2 of 5 14-1/4'' 362mm HFL HighFocus High mast LED: 92, 184 and 276 LED LED Modules 2 modules 4 modules 6 modules Predicted Lumen Depreciation Data Predicted performance derived from LED manufacturer’s data and engineering design estimates, based on IESNA LM-80 methodology. Actual experience may vary due to field application conditions.L70 is the predicted time when LED performance depreciates to 70% of initial lumen output. Calculated per IESNA TM21-11. Published L70 hours limited to 6 times actual LED test hours. Ambient Temperature °C Driver mA Calculated L70 Hours L70 per TM-21 Lumen Maintenance % at 51,000 hrs 25°C 1050 mA >100,000 hours >51,000 hours >90% Specifications Housing Heat Sink Driver Made of a low copper die cast Aluminum alloy (A360) for a high resistance to corrosion, 0.100" (2.5mm) minimum thickness. Fits on a 2 3/8" (60mm) O.D. (2" NPS) by 5 1/2" (140mm) minimum long tenon. Comes with a zinc plated clamp fixed by 4 zinc plated hexagonal bolts 3/8-16 UNC for ease of installation. Provides an easy step adjustment of +/ 3° tilt in 3° increments. A single screw with sealing washer, hinged, removable door opens upward to provide access to electronic components and to a terminal block. Door is secured to prevent accidental dropping or disengagement. Electrical compartment rated IP65 seal per ANSI C136.25, provided with a pre-installed gasket. Complete with a bird guard installed which seals around tenon and protects against birds and similar intruders. ANSI label to identify wattage and source (included in box). Anodized 6063-T5 Aluminum for a high resistance to corrosion, designed to ensure high efficacy and superior cooling by natural vertical convection air flow pattern always close to LEDs and driver optimizing their efficiency and life. Product does not use any cooling device with moving parts (only passive cooling). Wide openings enable natural cleaning and removal of dirt and debris. Entire luminaire is rated for operation in ambient temperature of -40°C / -40°F up to +40°C / +104°F. High power factor of 90% min. Electronic driver, operating range 50/60 Hz. Auto adjusting universal voltage input from 120 to 277 VAC or 347 to 480 VAC rated for both application line to line or line to neutral, Class I, THD of 20% max. Light Engine Composed of 4 main components: Heat Sink / LED Module / Optical System / Driver Electrical components are RoHS compliant, IP66 sealed light engines. LEDs tested by ISO 17025-2005 accredited lab in accordance with IESNA LM-80 guidelines in compliance with EPA ENERGY STAR, extrapolations in accordance with IESNA TM-21. Metal core board ensures greater heat transfer and longer lifespan. HFL_Spec 04/16 page 3 of 5 LED Module Composed of high performance white LEDs. Color temperature as per ANSI/NEMA bin Neutral White, 4000 Kelvin nominal (3985 +/- 275K or 3710K to 4260K), CRI 70 Min. Optical System Composed of high performance UV stabilized optical grade polymer refractor lenses to achieve desired distribution optimized to get maximum spacing, target lumens and a superior lighting uniformity. System is rated IP66. Performance shall be tested per LM-63, LM-79 and TM-15 (IESNA) certifying its photometric performance. 0% uplight and U0 per IESNA TM-15. NOTE: Entire optical assembly rotatable, enabling alignment of asymmetric optics parallel with roadway to optimize optical performance. The current supplying the LEDs will be reduced by the driver if the driver experiences internal overheating as a protection to the LEDs and the electrical components. Output is protected from short circuits, voltage overload and current overload. Automatic recovery after correction. Standard built in driver surge protection of 2.5kV (min). Integrated Features DD: Dimmable driver 0-10V. SP1: Surge protector tested in accordance with ANSI/IEEE C62.45 per ANSI/IEEE C62.41.2 Scenario I Category C High Exposure 10kV/10kA waveforms for Line Ground, Line Neutral and Neutral Ground, and in accordance with U.S. DOE (Department of Energy) MSSLC (Municipal Solid State Street Lighting Consortium) Model Specification for LED Roadway Luminaires Appendix D Electrical Immunity High Test Level 10kV / 10kA. Please note that these integrated features always come with HighFocus luminaires. HFL HighFocus High mast LED: 92, 184 and 276 LED Specifications (continued) Driver and Luminaire Options NOTE: HighFocus LED high mast luminaires will be shipped controls ready when you select either 5-pin or 7-pin receptacle option; 0-10V dimming driver is standard. Contact your local Sales Representative for more information and for help with putting together the entire system solution. AMPD: Driver pre-programmed for compatibility with Amplight control system. AMPD not available with HVU (347480V) Luminaire Useful Life HS: External house side shield. Wiring PH9 TLRD5*: Receptacle with 5 pins enabling dimming, can be used with a twist lock control node or photoelectric cell or a shorting cap. TLRD7*: Receptacle with 7HIS pins enabling dimming additional functionality (to be determined), can be used with a twist lock control node or photoelectric cell or a shorting cap. HS PH8 SPC RC The connection of the luminaire is done using a terminal block connector 600V, 85A for use with #2-#14 AWG wires from the primary circuit, located inside the housing. Due to the inrush current that occurs with electronic drivers, recommend using a time delay or slow blow fuse to avoid unnecessary and unwanted fuse blowing that can occur with fast acting fuses. Please note: Additional hardware will be required to utilize the additional 2 pins on this receptacle. HIS: Internal house HIS side shield, 1 per LED light engine. PH8*: Twist-lock Photoelectric Cell, UNIV PH8 SPC (120-277AC). PH9 Refer to IES files for energy consumption and delivered lumens for each option. Based on ISTMT in situ thermal testing in accordance with UL1598 and UL8750, Philips System Reliability Tool, driver data and LED LM-80/ TM-21, expected to reach 100,000 + hours with >L70 lumen maintenance @ 25°C. Luminaire Useful Life accounts for LED lumen maintenance AND all of these additional factors including: LED life, driver life, PCB substrate, solder joints, on/off cycles, burning hours and corrosion. F1: Fusing, RC single (for 120, 277 or 347VAC). Hardware HS PH8 PH9 All exposed screws shall be stainless for a high resistance to corrosion. All seals and sealing devices are made and/or lined with EPDM and/ or silicone and/or rubber. Finish PH8/347*: Twist-lock Photoelectric Cell, HVU (347VAC). PH8/480*: Twist-lock Photoelectric Cell, HVU (480VAC). PHXL*: Twist-lock Photoelectric Cell, extended PH8life, UNIV (120-277VAC). PH9 SPC PH8 PH9*: Shorting cap. PH9 SPC RC * Use of photoelectric cell or shorting cap is required to ensure proper illumination. HFL_Spec 04/16 page 4 of 5 F2: Fusing, double (for 208, 240 or 480VAC). F3: Fusing, Canadian double pull (for 208, 240 or 480VAC). RC Color in accordance with the AAMA 2603 standard. Application of polyester powder coat paint (4 mils/100 microns) with ± 1 mils/24 microns of tolerance. The thermosetting resins provides a discoloration resistant finish in accordance with the ASTM D2244 standard, as well as luster retention in keeping with the ASTM D523 standard and humidity proof in accordance with the ASTM D2247 standard. The surface treatment achieves a minimum of 2000 hours for salt spray resistant finish in accordance with testing performed and per ASTM B117 standard. SPC HFL HighFocus High mast LED: 92, 184 and 276 LED Specifications (continued) LED products manufacturing standard The electronic components sensitive to electrostatic discharge (ESD) such as light emitting diodes (LEDs) are assembled in compliance with IEC61340-5-1 and ANSI/ ESD S20.20 standards so as to eliminate ESD events that could decrease the useful life of the product. Vibration Resistance The HFL meets the ANSI C136.31, American National Standard for Roadway Luminaire Vibration specifications for Bridge/overpass applications (Tested for 3G over 100,000 cycles by an independent lab). Certifications and Compliance High Mast System cULus Listed for Canada and USA. Luminaire meets DOE and MSSLC Model Specification for LED Roadway Luminaires. HighFocus LED high mast luminaires are DesignLights Consortium qualified. Luminaire complies with or exceeds the following ANSI C136 standards: .2, .3, .10, .15, .18, .22, .25, .31, .37, .41. Philips Lumec offers SkyMast raising and lowering device SMLS-G2 to accompany your HighFocus LED high mast luminaires. Visit our eCatalog or contact your local sales representative for more information. Limited Warranty 10-year limited warranty. See philips.com/warranties for details and restrictions. © 2016 Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. philips.com/luminaires HFL_Spec 04/16 page 5 of 5 Philips Lighting North America Corporation 200 Franklin Square Drive, Somerset, NJ 08873 Tel. 855-486-2216 Philips Lighting Canada Ltd. 281 Hillmount Rd, Markham, ON, Canada L6C 2S3 Tel. 800-668-9008