NanaWall® WD66 The Standard Wood Framed Folding System

Transcription

NanaWall® WD66 The Standard Wood Framed Folding System
INTRODUCTION | WD66
WD66 — The Standard Wood Framed Folding System
Weather Resistant
Life Cycle Performance
Engineered to provide high weather resistance and
structural performance. Excellent results were achieved
with independent testing per AAMA/WDMA /CSA 100/I.S.2/
A440, NAFS – North American Fenestration Standard. See
Performance Testing Results pages.
The WD66 meets the German “DIN EN 1191/12400
Classification,” where a unit is tested after 20,000 opening
and closing cycles and is still functional.
For benefits of all NanaWall systems, see the “General
Introduction” section. For features common to wood folding
systems, see the “Wood Folding Systems” Introduction.
The standard system is top hung, where the main weight is
carried by the head track. The bottom track is a guide.
NFRC-Approved Thermal Performance
The WD66 has been rated, certified and labeled in
accordance with NFRC 100 and 200; see the “Performance
and Testing Results” section for more details. 1 1/8” (28 mm)
and 1 1/2” (38 mm) triple glazing available. Energy Star values
can be met with selected glazing.
Florida Approval
Option of Top Hung (WD66/o) or Floor Supported System
(WD66/u)
The floor supported system is recommended for applications
where the vertical load bearing capability of the header is a
concern. The main weight is carried by the floor track. The
upper track is merely a guide.
Acoustical Performance
A five panel WD66 unit has been tested by an independent
acoustic lab for acoustical performance. The WD66 with STC
38 laminated glass achieved STC and Rw values of 37.
The WD66 is Florida statewide approved with Product
Approval number FL 18309. This information with limitations
can be viewed at http://www.floridabuilding.org.
1
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
TECHNICAL DESCRIPTION | WD66
General Description
Sliding/Folding Hardware
The WD66 is the standard commercial and/or residential
folding or paired-panel wood framed system designed to
provide an opening glass wall or storefront for widths up to
39’ (12 m); see Maximum Size Chart. It is available in various
configurations utilizing one to twelve panels; see elevation
drawings. The option exists for a swing entry/exit panel(s).
Units can be either inward-opening or outward-opening; see
section drawings.
For sliding and folding of each pair of panels, for the WD66/o
top hung system, a load-bearing, upper-running carriage
and a lower-running guide carriage is attached between
the two panels (shown in the section drawings). The double
pair, twin-tandem, upper-running carriage is constructed to
ensure even distribution of pressure on all four rollers.
For the WD66/u floor supported system, a floor supported,
lower running carriage and an upper running carriage as a
guide is attached between the panels. Rollers have sealed
bearings and are coated with toughened Polyamide to
ensure sound-free running and optimal resistance to extreme
temperature.
Frame and Panels
The three-layer, cross grained, solid wood panel frame
thickness is 2 5/8” (66 mm) or 3 1/16” (78 mm); see various
frame profiles in section drawings. The aluminum head
jamb of the WD66/o system is clad with matching wood
fascia pieces on both sides. Standard woods are European
Pine, Douglas Fir or Meranti. Other woods are also available.
Frames and panels have a sanding sealer or a base coat
applied to be field finished by others; see “Wood Finish
Options” in the General introduction. Panels are preassembled. All pins and screws to assemble the frame are
provided. The Raised Sill (higher weather performance
sill), thermally broken aluminum with 3/4”(18.5 mm) wide
polyamide plastic, and various flush sills are available in a
clear or dark bronze anodized finish.
Two to five patented clear or dark bronze anodized hinges
per connection are provided to connect panels together and
to connect panels to the frame.
Locking Hardware and Handle Options
For each pair of folding panels (except for the pair to be
opened first in a unit with no swing panel), provided is
two point locking hardware consisting of top and bottom
Polyamide capped locking rods operated by a 180º turn of a
flat handle on the inside only.
If there is a swing panel, there are the following hardware
options on the primary swing panel:
Glazing
Units can be supplied glazed with 15/16” (24 mm) double
insulating Low-E safety glass, clear double insulating safety,
1 1/8” (28 mm) and 1 1/2” (38 mm) triple insulating Low-E
safety, 1/4” (6 mm) single tempered or laminated, other high
performing safety glass such as Heat Mirror, acoustic, special
tint, etc., or other glass on request.
Weatherstripping
All weatherstripping consisting of EPDM or brush seals is
provided for sealing between panels and between panels and
frames; see section drawings.
1. Multi-point Locking. Consisting of lever handles on both
sides, a lockset, lockable latch, deadbolt and rods at the top
and the bottom. After turn of key or thumbturn, depression of
handles withdraws latch, lifting of handles engages rods and
turn of key or thumbturn engages deadbolt and locks.
For a unit with a secondary swing panel, available are
matching dummy lever handles on both sides and a concealed
flush bolt that operates the rods at the top and the bottom.
Available with profile cylinder or with SFIC adapter.
2. Deadbolt Lock. Consisting of push/pull handles on both
sides with deadbolt(s) operated by a lockset. Turn of key
or thumb turn operates lock. Available is a lockset option of
having key operation on both sides. To keep the panel closed,
a door closer should be field installed, but please note that
a door closer can only be installed for a swing panel that is
attached to the side jamb.
3. No Hardware. For panic hardware to be installed by
others, the main entry panel can be supplied with no locking
hardware.
2
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
TECHNICAL DESCRIPTION | WD66
For a unit with no swing panel, on the folding pair to be
opened first, provided is two point locking hardware consisting
of top and bottom Polyamide capped locking rods operated
by a 180º turn of an L-shaped handle for an inward opening
unit and a flat handle for an outward opening unit on the
inside. In both cases, there will be a flat handle on the outside.
Lockable with a lockset. Turn of key or thumb turn operates
lock. Please note that for an outward opening unit, locking from
the inside will need to be with a key that may not meet egress
requirements.
For a unit where locking/handles on the inside only is desired,
like in window applications, on all swing panels or pair of folding
panels to be opened first, provided is two point locking with a
flat handle on the inside only.
Handle Finish Schemes:
Standard – Stainless steel lever, flat, and L-shaped handles in
brushed satin or black titanium finish.
Push/pull handles are in brushed stainless steel.
Optional – Brass lever handles in oil rubbed brass or satin
nickel, and flat handles powdercoated dark brown or silver
gray.
3
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
TESTING RESULTS | WD66
HIGHER WEATHER PERFORMANCE RAISED SILL
Higher Weather Performance (Raised) Sill
WD66
TYPE OF TEST
INWARD OPENING UNITS
@
OUTWARD OPENING UNITS
1.57 psf (75 Pa): 0.08
@
1.57 psf (75 Pa): 0.04
(0.27 exfiltration)
e
(0.04 exfiltration)
e
A3
Air Infiltration
q
@
ASTM E-283, cfm/ft2
A3
6.24 psf (300 Pa):
0.05
@
No uncontrolled water entry
No uncontrolled water entry
Water Penetration q
@
6.24 psf (300 Pa):
0.18
9 psf (440 Pa)
@
9 psf (440 Pa)
ASTM E 331 and ASTM E-547
DESIGN PRESSURE e
Structural Load Deflection q
ASTM E-330: pass
See design windload charts for
other sized panels
41.5 psf
(2000 Pa)
Note that the structural test pressures were
50% higher than the design pressures.
Negative
Positive
@
DESIGN PRESSURE e
@
52.5 psf
(2520 Pa)
Class SP-PG40, Panel size - 3’ x 8’
(915 mm x 2471 mm)e
Positive
@
52.5 psf
(2520 Pa)
Negative
@
41.5 psf
(2000 Pa)
Class SP-PG40, Panel size - 3’ x 8’
(915 mm x 2471 mm)e
The WD66 meets the German “DIN EN 1191/12400 Classification,” where a unit
is tested after 20,000 opening and closing cycles and is still functional.
Life Cycle Performance
The WD66 is CE Mark Certfied
European CE Mark
In accordance with AAMA-1304 (1330 N (300 lbf) point load) requirements
Forced Entry Resistance
q
Acoustical Performance w
The WD66 system has been tested by an independent acoustic lab for acoustical
performance. the WD66 with STC 38 laminated glass achieved STC and Rw values of 37.
q Excerpts of results of 9’7” W x 8’6” H three panel unit with Standard (Raised) sill tested by Architectural Testing, Inc., Fresno, CA,
an independent testing laboratory in april 2013 per AAMA/WDMA/CSA 101/I.S.2/A440 , NAFS – North American Fenestration Standard.
w Excerpts of results of a unit tested by Nusing Mobile Trennwandtechnile, Munster, Germany, an independent testing laboratory in August 2005.
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016
Wall Systems,
e For Canada, tested to NAFS-08
orNana
equivalent
andInc.
CSA A44051-09.
www.nanawall.com
Rated, certified and labeled in accordance with NFRC 100 + 200
4
Life Cycle Performance
The WD66 is CE Mark Certfied
TESTING RESULTS | WD66
HIGHER WEATHER PERFORMANCE RAISED SILL
European CE Mark
Higher Weather Performance (Raised) Sill
In accordance with AAMA-1304 (1330 N (300 lbf) point load) requirements
Forced Entry Resistance
q
WD66 with 66 mm Profile / Top Hung Units
Acoustical Performance w
The WD66 system has been tested by an independent acoustic lab for acoustical
performance. the WD66 with STC 38 laminated glass achieved STC and Rw values of 37.
q Excerpts of results of 9’7” W x 8’6” H three panel unit with Standard (Raised) sill tested by Architectural Testing, Inc., Fresno, CA,
an independent testing laboratory in april 2013 per AAMA/WDMA/CSA 101/I.S.2/A440 , NAFS – North American Fenestration Standard.
w Excerpts of results of a unit tested by Nusing Mobile Trennwandtechnile, Munster, Germany, an independent testing laboratory in August 2005.
e For Canada, tested to NAFS-08 or equivalent and CSA A44051-09.
Rated, certified and labeled in accordance with NFRC 100 + 200
66 MM THICK PROFILE
Thermal Performance
INWARD OPENING UNITS
OUTWARD OPENING UNITS
TYPE OF
GLASS (1 LITE)r
CENTER
OF GLASS
U-FACTOR
IG GLASS
THICKNESS
UNIT
U-FACTOR
SHGCt
VTy
2015
ENERGY
STAR
UNIT
U-FACTOR
SHGCt
VTy
2015
ENERGY
STAR
Double IG Clear
(air filled)
.48
15/16”
(24 mm)
.44
.45
.48
–
.44
.45
.48
–
Double IG Standard
Low E (argon filled)
.26
15/16”
(24 mm)
.29
.23
.41
Ü
.29
.23
.41
Ü
Double IG Standard
Low E (air filled)
.30
15/16”
(24 mm)
.32
.24
.41
–
.32
.24
.41
_
Double IG Low E
Alternate (argon filled)
.26
15/16”
(24 mm)
.29
.29
.43
ÜÜ
.29
.29
.43
ÜÜ
Double IG Low E
Alternate (air filled)
.30
15/16”
(24 mm)
.32
.29
.43
–
.32
.29
,43
–
Triple IG Low E x 2
(argon filled)
.13
1 1/8”
(28 mm)
.24
.20
.31
Ü
.24
.20
.31
Ü
Triple IG Low E x 2
(air filled)
.16
1 1/8”
(28 mm)
.27
.20
.31
Ü
.27
.20
.31
Ü
Rated, certified and labeled in accordance with NFRC 100 + 200
66 MM THICK PROFILE
Thermal Performance
INWARD OPENING UNITS
TYPE OF
GLASS (1 LITE)r
CENTER
OF GLASS
U-FACTOR
IG GLASS
THICKNESS
Double IG Clear
(air filled)
.48
15/16”
(24 mm)
OUTWARD OPENING UNITS
2015 TO CHANGE WITHOUT NOTICE
AND DETAILS SUBJECT
UNIT SPECIFICATIONS
UNIT
©2016
Nanat
Wall Systems,
SHGC
VTy Inc. ENERGY
SHGCt
U-FACTORwww.nanawall.com
U-FACTOR
STAR
.44
.46
.49
–
.44
.46
VTy
2015
ENERGY
STAR
.49
–
5
Standard (argon filled)
Double IG Low E
Double(argon
IG Lowfilled)
E
Alternate
Standard (air filled)
Ü
(24 mm)
.26
.30
Double IG Low E
.30
Double
IG
Low
E
TESTING
RESULTS
| WD66
Alternate
(air
filled)
.26
Alternate (argon filled)
Triple IG Low E x 2
Double
Low E
(argonIGfilled)
Alternate (air filled)
.13
.30
Triple IG Low E x 2
Triple(air
IGfilled)
Low E x 2
(argon filled)
.16
.13
Triple IG Low E x 2
(air filled)
.16
Ü
15/16”
15/16”
(24
mm)
(24 mm)
.29
.32
.29
.24
.43
.41
15/16”
15/16”
(24
mm)
(24 mm)
.32
.29
.29
.30
.43HIGHER– WEATHER
.32
.43
.29
ÜÜ
1 1/8”
15/16”
(28
mm)
(24 mm)
.24
.32
.20
.30
.31
.43
ÜÜ
–
.29
.32
Ü
–
.29
.24
.43
.41
.29
,43 RAISED
–
PERFORMANCE
SILL
.29
.43
ÜÜ
.20
.30
.31
,43
Ü
–
.27
.20
.31
.27
.20
1 1/8”
Ü
(28
mm)66 mm
WD66 with
.24 Profile
.20 / Floor
.31 Supported
.24Units .20
Ü
(28 mm)
.31
.31
Ü
Ü
.24
.32
Higher Weather Performance (Raised) Sill
Triple IG Low E x 2
(argon filled) 78 mm
thick profile only
1 1/8”
1 1/8”
(28 mm)
1 1/2”
Thermal Performance
.13
TYPE OF
GLASS (1 LITE)r
ÜÜ
_
(88 mm)
CENTER
OF GLASS
U-FACTOR
IG GLASS
THICKNESS
Thermal Performance15/16”
Double IG Clear
(air filled)
.48
Double
IG OF
Low E
TYPE
r
Standard
GLASS (argon
(1 LITE)filled)
CENTER
.26
OF GLASS
U-FACTOR
Double IG Low E
Double IG Low E
Standard (air filled)
Standard (argon filled)
Rated,
.21 certified
.31and labeled in accordance
.27 with NFRC
.21 100 + 200
.31
Ü
.27
.20
.20
.31
66 MM THICK PROFILE
ÜÜ
.21
INWARD OPENING UNITS
UNIT
U-FACTOR
.20
.31
VT
ÜÜ
OUTWARD OPENING UNITS
2015 in accordance with NFRC 100 + 200
Rated, t
certifiedyand labeled
UNIT
t
y
SHGC
Ü
ENERGY
STAR
U-FACTOR
SHGC
VT
2015
ENERGY
STAR
78 MM THICK PROFILE
.44
.46
.49
–
.44
.46
.49
–
IG15/16”
GLASS
(24 mm)
THICKNESS
UNIT
.29
U-FACTOR
.24 t
SHGC
.41y
VT
2015
ENERGY
Ü
STAR
UNIT
.29
U-FACTOR
.24 t
SHGC
.41y
VT
2015
ENERGY
Ü
STAR
.30
.26
15/16”
1 1/8”
(24 mm)
(28 mm)
.32
.27
.24
.23
.41
.40
Ü
–
.32
.27
.24
.23
.41
.40
Ü
Double IG Low E
Double IG Low E
Alternate (argon filled)
Standard (air filled)
.26
.30
15/16”
1 1/8”
(24 mm)
(28 mm)
.29
.30
.30
.23
.43
.40
ÜÜ
Ü
.29
.30
.29
.23
.43
.40
ÜÜ
Ü
Double IG Low E
Triple IG Low E
Alternate (air filled)
Standard (argon filled)
.30
.13
15/16”
1 7/16”
(24 mm)
(38 mm)
.32
.20
.30
.20
.43
.31
Ü
–
.32
.21
.30
.20
,43
.31
Ü
Triple IG Low E x 2
Triple IG Low E
(argon filled)
Standard (air filled)
.13
.16
1 1/8”
1 7/16”
(28 mm)
(38 mm)
.24
.23
.20
.20
.31
.31
Ü
Ü
.24
.23
.20
.20
.31
.31
Ü
Ü
Triple IG Low E x 2
Triple IG Low E
(air filled)
Alternate (argon filled)
.16
.13
1 1/8”
1 7/16”
(28 mm)
(38 mm)
.27
.18
.21
.23
.31
.34
Ü
Ü
.27
.19
.21
.22
.31
.34
Ü
Ü
Triple IG Low E x 2
Triplefilled)
IG Low
(argon
78 Emm
Alternate
(air
filled)
thick profile only
.163
1/2”
117/16”
(88
(38 mm)
.20
.20
.22
.31
.34
ÜÜ
Ü
.21
.20
.22
.31
.34
ÜÜ
Ü
(24 mm)
INWARD OPENING UNITS
OUTWARD OPENING UNITS
_
–
NOTES
Rated, certified and labeled in accordance with NFRC 100 + 200
t SHGC = Solar Heat Gain
r NFRC simulated U factors of units with a horizontal mullion will have values of .01 to .02 higher than units
Coefficient
with no horizontal mullion. Please contact NanaWall for details.
78 MM THICK PROFILE y VT = Visible Transmittance
Thermal Performance
INWARD OPENING UNITS
OUTWARD OPENING UNITS
Ü 2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <25 in South/South Central zones and <. .40
in North/North
CENTER Central zones. (for guidance only. NanaWall is not a participant
2015 of the Energy Star program.)
2015
TYPE OF
GLASS (1 LITE)r
OF GLASS
U-FACTOR
IG GLASS
THICKNESS
UNIT
U-FACTOR
SHGCt
VTy
ENERGY
STAR
UNIT
U-FACTOR
SHGCt
VTy
ENERGY
STAR
ÜÜ Meets SHGC energy Star Qualification criteria for north/north central zones only.
Double IG Low E
Standard (argon filled)
.26
1Call
1/8”NanaWall for U-Factor & SHGC for other glass types
.27
.23
.40
Ü
(28 mm)
.27
.23
.40
Ü
Double IG Low E
Standard (air filled)
.30
1 1/8”
(28 mm)
.30
.23
.40
Ü
Triple IG Low E
Standard (argon filled)
.13
Low Profile SaddleÜSill
1 7/16”
(38 mm)
.30
.23
.20
WD66
TYPE OF TEST
Triple IG Low E
Standard (air filled)
.16
.40
Ü
INWARD OPENING UNITS
1 7/16”
(38 mm)
.23
6
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
.20
.31
.21
.20
www.nanawall.com
.20
.31
Ü
.31
Ü
OUTWARD OPENING UNITS
.23
.20
.31
Ü
Double IG Low E
Alternate (air filled)
.30
15/16”
(24 mm)
.32
.30
.43
–
.32
.30
,43
–
Triple IG Low E x 2
(argon filled)
.13
1 1/8”
(28 mm)
.24
.20
.31
Ü
.24
.20
.31
Ü
Triple IG Low E x 2
(air filled)
.16
1 1/8”
(28 mm)
.27
Ü
.27
TESTING RESULTS | WD66
HIGHER WEATHER PERFORMANCE RAISED SILL
.21
.31
.21
Higher Weather Performance
(Raised) Sill
ÜÜ
Triple IG Low E x 2
(argon filled) 78 mm
thick profile only
.13
1 1/2”
(88 mm)
.20
.20
.31
.21
WD66 with 78 mm Profile / Floor Supported Units
.20
.31
Ü
.31
ÜÜ
Rated, certified and labeled in accordance with NFRC 100 + 200
78 MM THICK PROFILE
Thermal Performance
INWARD OPENING UNITS
OUTWARD OPENING UNITS
TYPE OF
GLASS (1 LITE)r
CENTER
OF GLASS
U-FACTOR
IG GLASS
THICKNESS
UNIT
U-FACTOR
SHGCt
VTy
2015
ENERGY
STAR
UNIT
U-FACTOR
SHGCt
VTy
2015
ENERGY
STAR
Double IG Low E
Standard (argon filled)
.26
1 1/8”
(28 mm)
.27
.23
.40
Ü
.27
.23
.40
Ü
Double IG Low E
Standard (air filled)
.30
1 1/8”
(28 mm)
.30
.23
.40
Ü
.30
.23
.40
Ü
Triple IG Low E
Standard (argon filled)
.13
1 7/16”
(38 mm)
.20
.20
.31
Ü
.21
.20
.31
Ü
Triple IG Low E
Standard (air filled)
.16
1 7/16”
(38 mm)
.23
.20
.31
Ü
.23
.20
.31
Ü
Triple IG Low E
Alternate (argon filled)
.13
1 7/16”
(38 mm)
.18
.23
.34
Ü
.19
.22
.34
Ü
Triple IG Low E
Alternate (air filled)
.16
1 7/16”
(38 mm)
.20
.22
.34
Ü
.21
.22
.34
Ü
NOTES
t SHGC = Solar Heat Gain
Coefficient
y VT = Visible Transmittance
r NFRC simulated U factors of units with a horizontal mullion will have values of .01 to .02 higher than units
with no horizontal mullion. Please contact NanaWall for details.
Ü 2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <25 in South/South Central zones and <. .40
in North/North Central zones. (for guidance only. NanaWall is not a participant of the Energy Star program.)
ÜÜ Meets SHGC energy Star Qualification criteria for north/north central zones only.
Call NanaWall for U-Factor & SHGC for other glass types
Low Profile Saddle Sill
WD66
TYPE OF TEST
INWARD OPENING UNITS
@
1.57 w psf (75 Pa): 0.17
OUTWARD OPENING UNITS
@
1.57 psf (75 Pa): 0.17
(0.17 exfiltration)
(0.05 exfiltration)
SPECIFICATIONS e
AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
A2
Air Infiltration q
ASTM E-283,cfm/ft2
@
6.24 psf (300 Pa):
A2
@
e
6.24 psf (300 Pa):
7
Ü 2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <25 in South/South Central zones and <. .40
in North/North Central zones. (for guidance only. NanaWall is not a participant of the Energy Star program.)
ÜÜ Meets SHGC energy Star Qualification criteria for north/north central zones only.
TESTING RESULTS | WD66
LOW PROFILE SADDLE SILL
Call NanaWall for U-Factor & SHGC for other glass types
Low Profile Saddle Sill
WD66
TYPE OF TEST
INWARD OPENING UNITS
@
OUTWARD OPENING UNITS
1.57 w psf (75 Pa): 0.17
@
1.57 psf (75 Pa): 0.17
(0.17 exfiltration)
(0.05 exfiltration)
A2
A2e
e
Air Infiltration q
ASTM E-283,cfm/ft2
@
6.24 psf (300 Pa):
0.18
@
6.24 psf (300 Pa):
0.31
Low Profile Saddle Sill (top hung system - internally tested)
No uncontrolled water entry
@
5.43 psf (250 Pa)
Subject to the following additional adaptations of the sill in the field by others:
1. Remove the gaskets covering the inner channel.
2. Drill weep holes through the bottom of this channel (about one 1” x 1/4” diameter weep
hole per panel.)
3. Drill weep holes through the bottom of the sill or lower front face of the sill to drain
water collected to a lower point (about one 1” x 1/4” weep hole per panel, or equivalent
circular holes.)
Water Penetrationqw
ASTM E-547 and E-331
Please note that due to varying site requirements and conditions, these sills will not
be prepared for drainage by Nana Wall Systems, Inc. if this drainage system is desired,
we recommend that a qualified professional construct this system on the project site
strictly in accordance with nanawall instructions with good waterproofing techniques. if
drain connections are not made or are not possible, unit may leak with wind driven rain.
DESIGN PRESSURE w
Positive
Structural Load Deflection q
ASTM E-330: pass
See design windload charts for
other sized panels
@
45 psf
(2160 Pa)
Negative
@
55 psf
(2630 Pa)
Class SP-PG30, Panel size - 3’ x 8’
(915 mm x 2461 mm) w
(weepholes by others)
DESIGN PRESSURE w
Positive
@
55 psf
(2630 Pa)
Negative
@
45 psf
(2160 Pa)
Class SP-PG30, Panel size - 3’ x 8’
(915 mm x 2461 mm) w
(weepholes by others)
in accordance with AAMA-1304 (1330N (300 lb) point load)
Forced Entry Resistance
q
The WA66 meets the German “DIN EN 1191/12400 Classification,” where a unit
is tested after 20,000 opening and closing cycles and is still functional.
Life Cycle Performance
8
WD66 is CE Mark Certified
European CE Mark
Positive
Structural Load Deflection q
ASTM E-330: pass
See design windload charts for
other sized panels
@
Negative
45 psf
@
(2160 Pa)
Positive
55 psf
@
(2630 Pa)
55 psf
@
(2630 Pa)
Class SP-PG30, Panel size - 3’ x 8’
(915 mm x 2461 mm) w
(weepholes by others)
TESTING RESULTS | WD66
Negative
45 psf
(2160 Pa)
Class SP-PG30, Panel size - 3’ x 8’
LOW
(915
mm xPROFILE
2461 mm) w SADDLE
(weepholes by others)
SILL
Low Profile Saddle Sill
in accordance with AAMA-1304 (1330N (300 lb) point load)
Forced Entry Resistance
WD66 with 66 mm Profile / Top Hung Units
q
The WA66 meets the German “DIN EN 1191/12400 Classification,” where a unit
is tested after 20,000 opening and closing cycles and is still functional.
Life Cycle Performance
WD66 is CE Mark Certified
European CE Mark
q Excerpts of results of 9’7” w x 8’6” h three panel units (3l and 3R configurations) with Raised Sill tested by Architectural Testing, Inc., Fresno, CA,
an independent testing laboratory in April 2013 per aaMa/wdMa/cSa101/i.S.2/a440, nafS-North American Fenestration Standard.
w Inswing unit not tested. Results based on deduction from outswing unit test results.
e For Canada, tested to NAFS-08 or equivalent and CSA A44051-09.
Rated, certified and labeled in accordance with NFRC 100 + 200
66 MM THICK LOW PROFILE SADDLE SILL
Thermal Performance
INWARD OPENING UNITS
OUTWARD OPENING UNITS
TYPE OF
GLASS (1 LITE) r
CENTER
OF GLASS
U-FACTOR
IG GLASS
THICKNESS
UNIT
U-FACTOR
SHGCt
VTy
2015
ENERGY
STAR
UNIT
U-FACTOR
SHGCt
VTy
2015
ENERGY
STAR
Double IG Clear
(air filled)
.48
15/16”
(24 mm)
.44
.46
.49
–
.44
.46
.49
–
Double IG Standard
Low E (argon filled)
.26
15/16”
(24 mm)
.29
.24
.41
Ü
.29
.24
.41
Ü
Double IG Standard
Low E (air filled)
.30
15/16”
(24 mm)
.32
.24
.41
–
.32
.24
.41
–
Double IG Alternate
Low E (argon filled)
.26
15/16”
(24 mm)
.29
.30
.43
ÜÜ
.29
..30
.43
ÜÜ
Double IG Alternate
Low E (air filled)
.30
15/16”
(24 mm)
.32
.30
.43
–
.32
.30
.43
–
Triple IG Low E x 2
(argon filled)
.13
1 1/8”
(28 mm)
.24
.20
.31
Ü
.24
.20
.31
Ü
Triple IG Low E x 2
(air filled)
.16
1 1/8”
(28 mm)
.27
.21
.31
Ü
.27
.20
.31
Ü
Rated, certified and labeled in accordance with NFRC 100 + 200
66 MM THICK LOW PROFILE SADDLE SILL
Thermal Performance
INWARD OPENING UNITS
TYPE OF
GLASS (1 LITE)r
Double IG Clear
CENTER
OF GLASS
U-FACTOR
.48
IG GLASS
THICKNESS
15/16”
9
OUTWARD OPENING UNITS
UNIT
U-FACTOR
SHGCt
VTy
2015
ENERGY
STAR
UNIT
U-FACTOR
SHGCt
VTy
2015
ENERGY
STAR
.45
.46
.49
–
.45
.46
.49
–
Double IG Alternate
Low E (argon filled)
Double IG Alternate
Low E (argon filled)
Double IG Alternate
Low E (air filled)
Double IG Alternate
E (air filled) |
TESTING Low
RESULTS
Triple IG Low E x 2
(argon filled)
Triple IG Low E x 2
(argon filled)
Triple IG Low E x 2
(air filled)
Triple IG Low E x 2
Triple(air
IGfilled)
Low E x 2
(argon filled) 78 mm
thick profile only
.26
.26
.30
.30
WD66
.13
.13
.16
.16
15/16”
(24 mm)
15/16”
(24 mm)
15/16”
(24 mm)
15/16”
(24 mm)
1 1/8”
(28 mm)
1 1/8”
(28 mm)
1 1/8”
(28 mm)
1 1/8”
(28 mm)
1 7/16”
(38 mm)
.29
.30
.44
ÜÜ
.29
.30
.44
ÜÜ
.29
.30
.43
ÜÜ
.29
..30
.43
ÜÜ
.32
.30
.44
–
.32
.30
.44
–
.32
.30
.43
–
.32
.30
.43
–
.24
.21
.32
Ü
.24
.21
.32
Ü
.24
.20
.31
Ü
Ü
.24
.20
.31
.27
.21
.32
Ü
Ü
.27
.20
.31
Ü
.31
Ü
Low Profile Saddle ÜSill
.27
.21
.32
.27
.21
.31
LOW PROFILE SADDLE SILL
WD66
with 66 mm.21Profile.20/ Floor.31 Supported
.13
.21Units .20
Ü
Rated, certified and labeled in accordance with NFRC 100 + 200
Rated, certified and labeled in accordance with NFRC 100 + 200
66 MM THICK LOW PROFILE SADDLE SILL
Thermal Performance
INWARD OPENING UNITS
OUTWARD OPENING UNITS
78 MM THICK FLUSH SILL
Thermal Performance
2015
UNIT
t
OUTWARD
OPENING
ENERGY
SHGC
VTyUNITS
U-FACTOR
STAR
TYPE OF
GLASS (1 LITE)r
CENTER
OF GLASS
U-FACTOR
IG GLASS
THICKNESS
2015
UNIT
t
y ENERGY
INWARDSHGC
OPENING
VTUNITS
U-FACTOR
STAR
TYPEIGOF
Double
Clear
GLASS
LITE) r
(air(1filled)
CENTER
OF GLASS
.48
U-FACTOR
IG15/16”
GLASS
THICKNESS
(24 mm)
UNIT
.45
U-FACTOR
t
SHGC
.46
y
VT
.49
2015
ENERGY
–
STAR
UNIT
.45
U-FACTOR
t
SHGC
.46
y
VT
.49
2015
ENERGY
–
STAR
Double
DoubleIGIGStandard
Low E
Low E (argon
Standard
(argonfilled)
filled)
.26
.26
15/16”
1 1/8”
(24 mm)
mm)
(28
.30
.27
.24
.23
.42
.41
Ü
.29
.27
.24
.23
.42
.41
Ü
Double IG Standard
Double
IG Low
Low E (air
filled)E
Standard (air filled)
.30
.30
15/16”
1 1/8”
(24
mm)
(28 mm)
.32
.30
.24
.23
.42
.41
Ü
–
.32
.30
.24
.23
.42
.41
Ü
.29
.30
.44
.30
.44
.20
.31
ÜÜ
Ü
.29
.21
.21
.20
.31
ÜÜ
Ü
Double IG Alternate
Low E (argon filled)
Triple IG Low E
Standard (argon filled)
Double IG Alternate
Low E (air filled)
Triple IG Low E
Standard (air filled)
Triple IG Low E x 2
(argon filled)
.26
.13
.30
.16
.13
15/16”
(24 mm)
1 7/16”
(38 mm)
–
15/16”
(24 mm)
1 7/16”
(38 mm)
1 1/8”
(28 mm)
.32
.30
.44
–
.32
.30
.44
–
.23
.20
31
.23
.20
.31
.25
.21
.32
Ü
Ü
.24
.21
.32
Ü
Ü
Triple IG Low E
Alternate
Triple IG(argon
Low Efilled)
x2
(air filled)
.13
.16
1 7/16”
(38
mm)
1 1/8”
(28 mm)
.19
.27
.23
.21
.35
.32
Ü
Ü
.19
.27
.23
.21
.35
.32
Ü
Ü
TripleIGIGLow
LowE Ex 2
Triple
Alternate
(air78
filled)
(argon
filled)
mm
thick profile only
.16
.13
1 7/16”
1 7/16”
(38
mm)
(38 mm)
.21
.21
.23
.20
.35
.31
Ü
Ü
.21
.21
.22
.20
.35
.31
Ü
Ü
NOTES
t SHGC
Rated,values
certified
and labeled
in accordance
with NFRC
100=+Solar
200 Heat Gain
r NFRC simulated u factors of units with a horizontal mullion will have
of about
.01 to .02
higher
Coefficient
than units with no horizontal mullion. Please contact nanawall for details.
y VT = Visible Transmittance
78 MM THICK LOW PROFILE SADDLE SILL
Thermal
Performance
Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <25 in South/South Central zones
Ü 2015 Energy
and <.40 in North/North Central zones. (For guidance only. NanaWall is not a participant of the Energy Star program.)
INWARD OPENING UNITS
TYPE OF
GLASS (1 LITE) r
OUTWARD OPENING UNITS
Ü Ü Meets SHGC Energy Star Qualification criteria for North/North
CENTER
2015Central zones only.
IG GLASS
UNIT
UNIT
OF GLASS
SHGCt
VTy ENERGY
SHGCt
THICKNESS
U-FACTOR
U-FACTOR
U-FACTOR
STAR
Call NanaWall for U-Factor & SHGC for other glass
types
VTy
2015
ENERGY
STAR
Double IG Low E
Standard (argon filled)
.26
1 1/8”
(28 mm)
.28
.23
.41
Ü
.28
.23
.41
Ü
Double IG Low E
Standard (air filled)
.30
1 1/8”
(28 mm)
.30
.23
.41
Ü
.30
.23
.41
Ü
Triple IG Low E
Standard (argon filled)
.13
1 7/16”
(38 mm)
.21
.20
.31
Ü
.21
.20
.31
Ü
10
Triple IG Low E
Standard (air filled)
Triple IG Low E
.16
.13
1 7/16”
(38 mm)
1 7/16”
.24
.19
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
.20
31
.24
.20
.31
Ü
.22
.34
Ü
.19
.22
.35
Ü
Ü
Double IG Alternate
Double
Alternate
Low EIG(air
filled)
Low E (air filled)
.30
.30
15/16”
15/16”
(24
mm)
(24 mm)
.32
.32
.30
.30
.44
.44
–
–
.32
.32
.30
.30
.44
.44
–
–
Triple IG Low E x 2
Triple
IG Low
Ex2
(argon
filled)
(argon filled)
.13
.13
1 1/8”
1 1/8”
(28
mm)
(28 mm)
.24
.25
.21
.21
.32
.32
Ü
Ü
.24
.24
.21
.21
.32
.32
Ü
Ü
Triple IG Low E x 2
Triple(air
IG filled)
Low E x 2
(air filled)
.16
.16
1 1/8”
(28
mm)
1 1/8”
(28 mm)
.27
.27
.21
.21
.32
.32
Ü
Ü
.27
.27
.21
.21
.32
.32
Ü
Ü
Triple IG Low E x 2
(argon
filled)
Triple IG
Low78
E xmm
2
thick filled)
profile78
only
(argon
mm
thick profile only
.13
.13
1 7/16”
(38
mm)
1 7/16”
(38 mm)
.21
.21
.20
.20
.31
.31
Ü
Ü
TESTING RESULTS | WD66
LOW PROFILE SADDLE SILL
Low Profile Saddle ÜÜSill
.21
.21
.20
.20
.31
.31
WD66 with 78 mm Profile / Floor Supported Units
Rated, certified and labeled in accordance with NFRC 100 + 200
Rated, certified and labeled in accordance with NFRC 100 + 200
Thermal Performance
Thermal Performance
78 MM THICK FLUSH SILL
78 MM THICK LOW PROFILE SADDLE SILL
INWARD OPENING UNITS
INWARD OPENING UNITS
OUTWARD OPENING UNITS
OUTWARD OPENING UNITS
TYPE OF
TYPE
OF r
GLASS
(1 LITE)
GLASS (1 LITE) r
CENTER
CENTER
OF
GLASS
OF
GLASS
U-FACTOR
U-FACTOR
IG GLASS
IG GLASS
THICKNESS
THICKNESS
UNIT
UNIT
U-FACTOR
U-FACTOR
SHGCt
SHGCt
VTy
VTy
2015
2015
ENERGY
ENERGY
STAR
STAR
UNIT
UNIT
U-FACTOR
U-FACTOR
SHGCt
SHGCt
VTy
VTy
2015
2015
ENERGY
ENERGY
STAR
STAR
Double IG Low E
Double(argon
IG Lowfilled)
E
Standard
Standard (argon filled)
.26
.26
1 1/8”
1 1/8”
(28
mm)
(28 mm)
.27
.28
.23
.23
.41
.41
Ü
Ü
.27
.28
.23
.23
.41
.41
Ü
Ü
Double IG Low E
Double IG
E
Standard
(airLow
filled)
Standard (air filled)
.30
.30
1 1/8”
1 1/8”
(28
mm)
(28 mm)
.30
.30
.23
.23
.41
.41
Ü
Ü
.30
.30
.23
.23
.41
.41
Ü
Ü
Triple IG Low E
Triple (argon
IG Lowfilled)
E
Standard
Standard (argon filled)
.13
.13
1 7/16”
1 7/16”
(38
mm)
(38 mm)
.21
.21
.20
.20
.31
.31
Ü
Ü
.21
.21
.20
.20
.31
.31
Ü
Ü
Triple IG Low E
Triple IG(air
Low
E
Standard
filled)
Standard (air filled)
.16
.16
1 7/16”
1 7/16”
(38
mm)
(38 mm)
.23
.24
.20
.20
31
31
Ü
Ü
.23
.24
.20
.20
.31
.31
Ü
Ü
Triple IG Low E
Triple (argon
IG Low filled)
E
Alternate
Alternate (argon filled)
.13
.13
1 7/16”
1 7/16”
(38
mm)
(38 mm)
.19
.19
.23
.22
.35
.34
Ü
Ü
.19
.19
.23
.22
.35
.35
Ü
Ü
Triple IG Low E
Triple IG(air
Low
E
Alternate
filled)
Alternate (air filled)
.16
.16
1 7/16”
1 7/16”
(38
mm)
(38 mm)
.21
.21
.23
.23
.35
.35
Ü
Ü
.21
.21
.22
.22
.35
.35
Ü
Ü
NOTES
Flush Sill
r NFRC simulated u factors of units with a horizontal mullion will have values of about .01 to .02 higher
than units with no horizontal mullion. Please contact nanawall for details.
WD66
t SHGC = Solar Heat Gain
Coefficient
y VT = Visible Transmittance
Ü 2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <25 in South/South Central zones
and
<.40 OF
in North/North
Central zones. (For guidance
only. OPENING
NanaWall is not
a participant of the OUTWARD
Energy Star program.)
TYPE
TEST
INWARD
UNITS
OPENING UNITS
Ü Ü Meets SHGC Energy Star Qualification criteria for North/North Central zones only.
w
@
psf (75 Pa):
@
psf (75 Pa):
Call NanaWall for U-Factor(0.&17SHGC
for other glass types
exfiltration)
(0.05 exfiltration)
1.57
0.17
1.57
A2e
Air Infiltration q
ASTM E-283,cfm/ft2
@
0.17
A2e
6.24 psf (300 Pa):
0.18
@
6.24 psf (300 Pa):
0.31
Flush Sill
(similar conditions with low profile saddle sill with weepage from middle channel only)
No uncontrolled water entry
@
2.92 psf (140 Pa)
(similar conditions for standard flush sill)
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
Water Penetrationqw
ASTM E-547 and E-331
Subject ©2016
to theNana
following
adaptations
of the sill in the field by others:
Wall Systems,
Inc.
www.nanawall.com
1. Drill weep
holes through the outer bottom wall in the middle channel (1 1/4” x 3/16”
weep hole per panel)
2. Drill weep holes through the lower front face of the sill to drain water collected
to a lower point (1 1/4” x 3/16” weep hole per panel)
11
Triple IG Low E
Alternate (argon filled)
.13
IG Low E | WD66
TESTING Triple
RESULTS
.16
Alternate (air filled)
1 7/16”
(38 mm)
.19
.22
.34
Ü
.19
.22
.35
1 7/16”
(38 mm)
.21
.23
.35
Ü
.21
.22
.35
Ü
FLUSH SILL
Ü
Flush Sill
Sill
WD66
WD66
TYPE OF TEST
INWARD OPENING UNITS
@
OUTWARD OPENING UNITS
1.57 w psf (75 Pa): 0.17
@
1.57 psf (75 Pa): 0.17
(0.17 exfiltration)
(0.05 exfiltration)
A2
A2e
e
Air Infiltration q
ASTM E-283,cfm/ft2
@
6.24 psf (300 Pa):
0.18
@
6.24 psf (300 Pa):
0.31
Flush Sill
(similar conditions with low profile saddle sill with weepage from middle channel only)
No uncontrolled water entry
@
2.92 psf (140 Pa)
(similar conditions for standard flush sill)
Subject to the following adaptations of the sill in the field by others:
1. Drill weep holes through the outer bottom wall in the middle channel (1 1/4” x 3/16”
weep hole per panel)
2. Drill weep holes through the lower front face of the sill to drain water collected
to a lower point (1 1/4” x 3/16” weep hole per panel)
Water Penetrationqw
ASTM E-547 and E-331
Please note that due to varying site requirements and conditions, these sills will not
be prepared for drainage by Nana Wall Systems, Inc. if this drainage system is desired,
we recommend that a qualified professional construct this system on the project site
strictly in accordance with nanawall instructions with good waterproofing techniques. if
drain connections are not made or are not possible, unit may leak with wind driven rain.
DESIGN PRESSURE w
Positive
Structural Load Deflection q
ASTM E-330: pass
See design windload charts for
other sized panels
@
45 psf
(2160 Pa)
Negative
@
55 psf
(2630 Pa)
Class SP-PG30, Panel size - 3’ x 8’
(915 mm x 2461 mm) w
(weepholes by others)
DESIGN PRESSURE w
Positive
@
55 psf
Negative
@
(2630 Pa)
45 psf
(2160 Pa)
Class SP-PG30, Panel size - 3’ x 8’
(915 mm x 2461 mm) w
(weepholes by others)
in accordance with AAMA-1304 (1330N (300 lb) point load)
Forced Entry Resistance
q
The WA66 meets the German “DIN EN 1191/12400 Classification,” where a unit
is tested after 20,000 opening and closing cycles and is still functional.
Life Cycle Performance
WD66 is CE Mark Certified
European CE Mark
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
q Excerpts of results of 9’7” w x 8’6” h three panel units (3l and 3R configurations) with Raised Sill tested by Architectural Testing, Inc., Fresno, CA,
an independent testing laboratory in April 2013 per aaMa/wdMa/cSa101/i.S.2/a440, nafS-North American Fenestration Standard.
12
Positive
Structural Load Deflection q
ASTM E-330: pass
See design windload charts for
other sized panels
@
Negative
45 psf
@
(2160 Pa)
Positive
55 psf
@
(2630 Pa)
55 psf
@
(2630 Pa)
Class SP-PG30, Panel size - 3’ x 8’
(915 mm x 2461 mm) w
(weepholes by others)
TESTING RESULTS | WD66
Negative
45 psf
(2160 Pa)
Class SP-PG30, Panel size - 3’ x 8’FLUSH
(915 mm x 2461 mm) w
(weepholes by others)
SILL
Flush Sill
in accordance with AAMA-1304 (1330N (300 lb) point load)
Forced Entry Resistance
WD66 with 66 mm Profile / Top Hung Units
q
The WA66 meets the German “DIN EN 1191/12400 Classification,” where a unit
is tested after 20,000 opening and closing cycles and is still functional.
Life Cycle Performance
WD66 is CE Mark Certified
European CE Mark
q Excerpts of results of 9’7” w x 8’6” h three panel units (3l and 3R configurations) with Raised Sill tested by Architectural Testing, Inc., Fresno, CA,
an independent testing laboratory in April 2013 per aaMa/wdMa/cSa101/i.S.2/a440, nafS-North American Fenestration Standard.
w Inswing unit not tested. Results based on deduction from outswing unit test results.
e For Canada, tested to NAFS-08 or equivalent and CSA A44051-09.
Rated, certified and labeled in accordance with NFRC 100 + 200
Thermal Performance
66 MM THICK FLUSH SILL
INWARD OPENING UNITS
OUTWARD OPENING UNITS
TYPE OF
GLASS (1 LITE) r
CENTER
OF GLASS
U-FACTOR
IG GLASS
THICKNESS
UNIT
U-FACTOR
SHGCt
VTy
2015
ENERGY
STAR
UNIT
U-FACTOR
SHGCt
VTy
2015
ENERGY
STAR
Double IG Clear
(air filled)
.48
15/16”
(24 mm)
.44
.46
.50
–
.44
.46
.50
_
Double IG Standard
Low E (argon filled)
.26
15/16”
(24 mm)
.28
.46
.41
Ü
.29
.24
.41
Ü
Double IG Standard
Low E (air filled)
.30
15/16”
(24 mm)
.32
.24
.41
–
.32
.24
.41
_
Double IG Alternate
Low E (argon filled)
.26
15/16”
(24 mm)
.28
.30
.43
ÜÜ
.29
.30
.43
ÜÜ
Double IG Alternate
Low E (air filled)
.30
15/16”
(24 mm)
.32
.30
.43
–
.31
.30
.43
–
Triple IG Low E x 2
(argon filled)
.13
1 1/8”
(28 mm)
.24
.20
.32
Ü
.24
.20
.32
Ü
Triple IG Low E x 2
(air filled)
.16
1 1/8”
(28 mm)
.27
.21
.32
Ü
.27
.21
.32
Ü
Rated, certified and labeled in accordance with NFRC 100 + 200
Thermal Performance
TYPE OF
GLASS (1 LITE) r
CENTER
OF GLASS
U-FACTOR
IG GLASS
THICKNESS
66 MM THICK FLUSH SILL
13
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana
Wall Systems,
Inc.
INWARD
OPENING
UNITS
OUTWARD OPENING
www.nanawall.com
UNIT
U-FACTOR
SHGCt
VTy
2015
ENERGY
STAR
UNIT
U-FACTOR
SHGCt
UNITS
VTy
2015
ENERGY
STAR
Double IG Alternate
Low E (argon filled)
Double IG Alternate
Low E (argon filled)
Double IG Alternate
Low E (air filled)
Double IG Alternate
Low E (air filled)
TESTINGTriple
RESULTS
IG Low E x 2 |
(argon filled)
Triple IG Low E x 2
(argon filled)
Triple IG Low E x 2
(air filled)
Triple IG Low E x 2
Triple(air
IGfilled)
Low E x 2
(argon filled) 78 mm
thick profile only
15/16”
(24 mm)
15/16”
(24 mm)
15/16”
(24 mm)
15/16”
(24 mm)
1 1/8”
(28 mm)
1 1/8”
(28 mm)
1 1/8”
(28 mm)
1 1/8”
(28 mm)
1 7/16”
(38 mm)
.29
.30
.44
ÜÜ
.29
.30
.44
ÜÜ
.28
.30
.43
ÜÜ
.29
.30
.43
ÜÜ
.32
.30
.44
–
.32
.30
.44
–
.32
.30
.43
–
.31
.30
.43
.24
.21
.32
Ü
.24
.21
.32
.24
.20
.32
.24
.20
.32
.27
.21
.32
Ü
Ü
.27
.21
.32
Ü
Ü
.27
.21
.32
Ü
.27
.21
.32
Ü
.13
.31
.21
Ü
WD66
with 66 mm.21Profile.20/ Floor
Supported
Units .20
.31
Ü
.26
.26
.30
.30
WD66
.13
.13
.16
.16
Flush Sill
–
FLUSH SILL
Ü
Rated, certified and labeled in accordance with NFRC 100 + 200
Rated, certified and labeled in accordance with NFRC 100 + 200
66 MM THICK FLUSH SILL
Thermal Performance
Thermal Performance
TYPE OF
GLASS (1 LITE) r
TYPE OF
Double(1IG
Clearr
GLASS
LITE)
(air filled)
CENTER
OF GLASS
U-FACTOR
CENTER
OF GLASS
.48
U-FACTOR
IG GLASS
THICKNESS
IG GLASS
15/16”
THICKNESS
(24 mm)
MM THICK FLUSH
SILL
INWARD OPENING78
UNITS
OUTWARD
OPENING UNITS
INWARD OPENING
UNITS 2015
UNIT
SHGCt
VTy ENERGY
U-FACTOR
STAR
2015
UNIT
t
y
ENERGY
SHGC
VT
U-FACTOR
.44
.47
.50
–
STAR
2015
OUTWARD OPENING
UNITS
UNIT
SHGCt
VTy ENERGY
U-FACTOR
STAR
2015
UNIT
t
y
ENERGY
SHGC
VT
U-FACTOR
.44
.47
.50
–
STAR
DoubleIGIGStandard
Low E
Double
Standard
(argonfilled)
filled)
Low E (argon
.26
.26
1 1/8”
15/16”
(28
(24 mm)
mm)
.27
.44
.23
.47
.41
.42
Ü
.27
.29
.23
.24
.41
.42
Ü
Double IG Standard
Double IG Low E
Low E (air filled)
Standard (air filled)
.30
.30
15/16”
1 1/8”
(24 mm)
(28 mm)
.32
.30
.24
.23
.42
.41
Ü
–
.32
.30
.24
.23
.42
.41
Ü
Double IG Alternate
Low
E (argon
Triple
IG Lowfilled)
E
Standard (argon filled)
.26
.13
15/16”
(24
mm)
1 7/16”
(38 mm)
.29
.21
.30
.20
.44
.31
ÜÜ
Ü
.29
.21
.30
.20
.44
.31
ÜÜ
Ü
Double IG Alternate
Low E (air filled)
Triple IG Low E
Standard (air filled)
Triple IG Low E x 2
(argon filled)
.30
.16
.13
–
15/16”
(24 mm)
1 7/16”
(38 mm)
1 1/8”
(28 mm)
.32
.30
.44
–
.32
.30
.44
–
.23
.20
31
Ü
.23
.20
.31
Ü
.24
.21
.32
Ü
.24
.21
.32
Ü
Triple IG Low E
Alternate
Triple IG(argon
Low Efilled)
x2
(air filled)
.13
.16
1 7/16”
(38
mm)
1 1/8”
(28 mm)
.19
.27
.23
.21
.35
.32
Ü
Ü
.19
.27
.23
.21
.35
.32
Ü
Ü
TripleIGIGLow
LowE Ex 2
Triple
Alternate
(air78
filled)
(argon
filled)
mm
thick profile only
.16
.13
1 7/16”
1 7/16”
(38
mm)
(38 mm)
.21
.21
.23
.20
.35
.31
Ü
Ü
.21
.21
.22
.20
.35
.31
Ü
Ü
NOTES
t SHGC
Rated, certified and labeled in accordance with NFRC
100=+Solar
200 Heat Gain
r NFRC simulated u factors of units with a horizontal mullion will have values of about .01 to .02 higher
Coefficient
than units with no horizontal mullion. Please contact nanawall for details.
y VT = Visible Transmittance
78 MM THICK FLUSH SILL
Thermal
Performance
Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <25 in South/South Central zones
Ü 2015 Energy
and <.40 in North/North Central zones. (For guidance only. NanaWall is not a participant of the Energy Star program.)
INWARD OPENING UNITS
OUTWARD OPENING UNITS
Ü Ü Meets SHGC Energy Star Qualification criteria for North/North Central zones only.
TYPE OF
GLASS (1 LITE) r
CENTER
OF GLASS
U-FACTOR
Double IG Low E
Standard (argon filled)
.26
1 1/8”
(28 mm)
.27
.23
.41
Ü
Double IG Low E
Standard (air filled)
.30
1 1/8”
(28 mm)
.30
.23
.41
Triple IG Low E
Standard (argon filled)
.13
1 7/16”
(38 mm)
.21
.20
.31
Triple IG Low E
Standard (air filled)
Triple IG Low E
.16
.13
2015
IG GLASS
UNIT
UNIT
SHGCt
VTy ENERGY
THICKNESS
U-FACTOR
Call NanaWall
for U-Factor & SHGC for other glass
types U-FACTOR
STAR
1 7/16”
(38 mm)
1 7/16”
SHGCt
VTy
2015
ENERGY
STAR
.27
.23
.41
Ü
Ü
.30
.23
.41
Ü
Ü
.21
.20
.31
Ü
14
.23
.19
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
.20
31
.23
.20
.31
Ü
.23
.35
.19
.23
.35
Ü
Double IG Alternate
Double IG Alternate
Low E (air filled)
Low E (air filled)
.30
.30
15/16”
15/16”
(24 mm)
(24 mm)
.32
.32
.30
.30
.44
.44
–
–
.32
.32
.30
.30
.44
.44
–
–
Triple IG Low E x 2
Triple IG Low E x 2
(argon filled)
(argon filled)
.13
.13
1 1/8”
1 1/8”
(28 mm)
(28 mm)
.24
.24
.21
.21
.32
.32
Ü
Ü
.24
.24
.21
.21
.32
.32
Ü
Ü
.27
.27
.21
.21
TESTING RESULTS | WD66
Triple IG Low E x 2
Triple IG Low E x 2
(air filled)
(air filled)
.16
.16
1 1/8”
1 1/8”
(28 mm)
(28 mm)
Triple IG Low E x 2
Triple IG Low E x 2
(argon filled) 78 mm
(argon filled) 78 mm
thick profile only
thick profile only
.13
.13
1 7/16”
1 7/16”
(38 mm)
(38 mm)
FLUSH SILL
.21
.21
.32
.32
Flush Sill
.20
.20
.31
.31
Ü
Ü
.27
.27
.21
.21
.32
.32
Ü
Ü
Ü
Ü
.21
.21
.20
.20
.31
.31
Ü
Ü
WD66 with 78 mm Profile / Floor Supported Units
Rated, certified and labeled in accordance with NFRC 100 + 200
Rated, certified and labeled in accordance with NFRC 100 + 200
Thermal
Thermal Performance
Performance
78
78 MM
MM THICK
THICK FLUSH
FLUSH SILL
SILL
INWARD
INWARD OPENING
OPENING UNITS
UNITS
OUTWARD
OUTWARD OPENING
OPENING UNITS
UNITS
TYPE OF
TYPE OF
GLASS (1 LITE) r
GLASS (1 LITE) r
CENTER
CENTER
OF GLASS
OF GLASS
U-FACTOR
U-FACTOR
IG GLASS
IG GLASS
THICKNESS
THICKNESS
UNIT
UNIT
U-FACTOR
U-FACTOR
SHGCt
SHGCt
VTy
VTy
2015
2015
ENERGY
ENERGY
STAR
STAR
UNIT
UNIT
U-FACTOR
U-FACTOR
SHGCt
SHGCt
VTy
VTy
2015
2015
ENERGY
ENERGY
STAR
STAR
Double IG Low E
Double IG Low E
Standard (argon filled)
Standard (argon filled)
.26
.26
1 1/8”
1 1/8”
(28 mm)
(28 mm)
.27
.27
.23
.23
.41
.41
Ü
Ü
.27
.27
.23
.23
.41
.41
Ü
Ü
Double IG Low E
Double IG Low E
Standard (air filled)
Standard (air filled)
.30
.30
1 1/8”
1 1/8”
(28 mm)
(28 mm)
.30
.30
.23
.23
.41
.41
Ü
Ü
.30
.30
.23
.23
.41
.41
Ü
Ü
Triple IG Low E
Triple IG Low E
Standard (argon filled)
Standard (argon filled)
.13
.13
1 7/16”
1 7/16”
(38 mm)
(38 mm)
.21
.21
.20
.20
.31
.31
Ü
Ü
.21
.21
.20
.20
.31
.31
Ü
Ü
Triple IG Low E
Triple IG Low E
Standard (air filled)
Standard (air filled)
.16
.16
1 7/16”
1 7/16”
(38 mm)
(38 mm)
.23
.23
.20
.20
31
31
Ü
Ü
.23
.23
.20
.20
.31
.31
Ü
Ü
Triple IG Low E
Triple IG Low E
Alternate (argon filled)
Alternate (argon filled)
.13
.13
1 7/16”
1 7/16”
(38 mm)
(38 mm)
.19
.19
.23
.23
.35
.35
Ü
Ü
.19
.19
.23
.23
.35
.35
Ü
Ü
Triple IG Low E
Triple IG Low E
Alternate (air filled)
Alternate (air filled)
.16
.16
1 7/16”
1 7/16”
(38 mm)
(38 mm)
.21
.21
.23
.23
.35
.35
Ü
Ü
.21
.21
.22
.22
.35
.35
Ü
Ü
NOTES
NOTES
r NFRC simulated u factors of units with a horizontal mullion will have values of about .01 to .02 higher
r NFRC simulated u factors of units with a horizontal mullion will have values of about .01 to .02 higher
than units with no horizontal mullion. Please contact nanawall for details.
than units with no horizontal mullion. Please contact nanawall for details.
t SHGC = Solar Heat Gain
t SHGC = Solar Heat Gain
Coefficient
Coefficient
y VT = Visible Transmittance
y VT = Visible Transmittance
Energy Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <25 in South/South Central zones
Ü 2015
Ü 2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <25 in South/South Central zones
and <.40 in North/North Central zones. (For guidance only. NanaWall is not a participant of the Energy Star program.)
and <.40 in North/North Central zones. (For guidance only. NanaWall is not a participant of the Energy Star program.)
SHGC Energy Star Qualification criteria for North/North Central zones only.
Ü Ü Meets
Ü Ü Meets SHGC Energy Star Qualification criteria for North/North Central zones only.
Call NanaWall for U-Factor & SHGC for other glass types
Call NanaWall for U-Factor & SHGC for other glass types
15
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
MAXIMUM SIZE CHART | WD66
NOTE: English dimensions are approximate.
Dimensions in parenthesis are in millimeters.
9’10” (3000)
Up to twelve panels are possible in a unit. Any
custom panel size is possible up to the maximum
size shown.
9’6” (2900)
A
9’2” (2800)
B
Solid dark
line on chart indicates maximum
frame height possible for a given maximum frame
width
8’10” (2700)
For heights above 8’4” (2550 mm),
panels have to be stiffened with a
horizontal mullion. (If no horizontal
mullion is desired, please see size chart
for 3 1/16" (78 mm) on page 7)
8’6” (2600)
8’2” (2500)
7’10” (2400)
7’6” (2300)
A&B
7’2” (2200)
A. For configurations hinged to a side jamb
combined with a pair(s) of folding panels or for
configurations with a pair(s) of folding panels only
includes models 1L, 1R, 1L1R, 2L, 2R, 1L2R, 2L1R,
2L2R, 4L, 4R, 1L4R, 4L1R, 2L4R, 4L2R, 6L, 6R, 1L6R,
6L1R, 4L4R, 2L6R, 6L2R, 4L6R, 6L4R, 6L6R.
B. For all configurations.
3’0”
6'10" (2100)
and below
NUMBER OF PANELS IN UNIT
FR AME HEIGHT OF UNIT
With 2 5/8" (66 mm) thick profile
For Single Glass, Double and 1 1/8" (28 mm)
Triple Insulated Glass - both top hung and
floor supported systems
1
1'11"
(600)
2’3”
(700)
2’7”
(800)
2’11”
(900)
3’3”
(1000)
2
3'11"
(1200
4’7”
(1400)
5’3”
(1600)
5’10”
(1800)
6’6”
(2000)
3
5"10"
(1800)
6’10”
(2100)
7’10”
(2400)
8’10”
(2700)
9’10”
(3000)
4
7'10"
(2400)
9’2”
(2800)
10’6”
(3200)
11’9”
(3600)
13’1”
(4000)
5
9'10"
(3000)
11’5”
(3500)
13’1”
(4000)
14’9”
(4500)
16’4”
(5000)
6
11'9"
(3600)
13’10”
(4200)
15’8”
(4800)
17’8”
(5400)
19’8”
(6000)
7
13'10"
(4200)
16’
(4900)
18’4”
(5600)
20’7”
(6300)
22’10”
(7000)
8
15'8"
(4800)
18’4”
(5600)
20’11”
(6400)
23’6”
(7200)
26’1”
(8000)
9
17'9"
(5400)
20’7”
(6300)
23’6”
(7200)
26’5”
(8100)
29’4”
(9000)
10
19'8"
(6000)
22’10”
(7000)
26’1”
(8000)
29’4”
(9000)
32’9”
(10000)
11
21'7"
(6600)
25’1”
(7700)
28’8”
(8800)
32’5”
(9900)
36’1"
(11000)
12
23'6"
(7200)
27’4”
(8400)
31’5”
(9600)
35’5”
(10800)
39’4"
(12000)
The maximum size limits are based on the maximum
weight of a panel that has a net glass thickness of
5/16” (8 mm) or 5/32” (4 mm) for each glass pane.
For thicker glass this maximum size limit chart will
not apply.
For configurations with only even number of
panels stacking to each side, the minimum width
of each panel is 2'3" (700 mm).
FR AME WIDTH OF UNIT
16
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
MAXIMUM SIZE CHART | WD66
NOTE: English dimensions are approximate.
Dimensions in parenthesis are in millimeters.
9’10” (3000)
9’6” (2900)
Solid dark
line on chart indicates maximum
frame height possible for a given maximum frame
width.
8’10” (2700)
8’6” (2600)
For triple glazing with heights above
8’4” (2550 mm) a horizontal mullion is
needed such that no glass pane is taller
than 7'10" (2400 mm).
B
8’2” (2500)
A. For configurations with a swing panel hinged
to a side jamb combined with a pair(s) of folding
panels or for configurations with a pair(s) of
folding panels only.
7’10” (2400)
7’6” (2300)
7’2” (2200)
Includes models 1L, 1R, 1L1R, 2L, 2R, 1L2R, 2L1R,
2L2R, 4L, 4R, 1L4R, 4L1R, 2L4R, 4L2R, 6L, 6R,
1L6R, 6L1R, 4L4R, 2L6R, 6L2R, 4L6R, 6L4R, 6L6R
6'10" (2100)
B. For all configurations.
A&B
and less
NUMBER OF PANELS IN UNIT
FR AME HEIGHT OF UNIT
For units with 1 1/2" (38 mm) Triple Insulated
Glass units and select units with Double
Insulated Glass if no horizontal mullion is
desired (for heights above 8'4") - FLOOR
SUPPORTED ONLY
Up to twelve panels are possible in a unit.
Any custom panel size is possible up to the
maximum size shown.
A
9’2” (2800)
With 3 1/16" (78 mm) thick profile
1
1'11"
(600)
2’3”
(700)
2’7”
(800)
2’11”
(900)
3’3”
(1000)
2
3'11"
(1200
4’7”
(1400)
5’3”
(1600)
5’10”
(1800)
6’6”
(2000)
3
5"10"
(1800)
6’10”
(2100)
7’10”
(2400)
8’10”
(2700)
9’10”
(3000)
4
7'10"
(2400)
9’2”
(2800)
10’6”
(3200)
11’9”
(3600)
13’1”
(4000)
5
9'10"
(3000)
11’5”
(3500)
13’1”
(4000)
14’9”
(4500)
16’4”
(5000)
6
11'9"
(3600)
13’10”
(4200)
15’8”
(4800)
17’8”
(5400)
19’8”
(6000)
7
13'10"
(4200)
16’
(4900)
18’4”
(5600)
20’7”
(6300)
22’10”
(7000)
8
15'8"
(4800)
18’4”
(5600)
20’11”
(6400)
23’6”
(7200)
26’1”
(8000)
9
17'9"
(5400)
20’7”
(6300)
23’6”
(7200)
26’5”
(8100)
29’4”
(9000)
10
19'8"
(6000)
22’10”
(7000)
26’1”
(8000)
29’4”
(9000)
(10000)
11
21'7"
(6600)
25’1”
(7700)
28’8”
(8800)
32’5”
(9900)
36’1"
(11000)
12
23'6"
(7200)
27’4”
(8400)
31’5”
(9600)
35’5”
39’4"
(10800)
(12000)
The maximum size limits are based on the
maximum weight of a panel that has a net glass
thickness of 1/2” (12 mm) for larger net thicker
glass, this maximum size limit chart will not apply.
For configurations with only even number of
panels stacking to each side, the minimum
width of each panel is 2' 9 1/2" (850 mm).
32’9”
FR AME WIDTH OF UNIT
17
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
RELATIONSHIP OF FRAME, PANEL AND GLASS DAYLIGHT OPENING SIZES | WD66
Dimensions in millimeters unless noted. Calculation applies to the standard stiles and rails with panel thickness
of 66 mm (2 5/8”) and nominal widths of 78 mm (3 1/16”).
Glass dimensions of all panels in a unit are equal unless unequal panel widths are used.
Nominal Panel Height (PH) is defined as Glass Daylight Opening Height + 156 (6 1/8”).
Nominal Panel Width (PW) is defined as Glass Daylight Opening Width + 156 (6 1/8”).
Panel Height is as seen from the inside on an inward opening unit and is as seen from the outside on an outward opening unit.
Please note that with the overlap of the head jamb and the sill with the panel, the Clear Opening Height will not be the same as
the Panel Height.
See Cross-Section Details of both stiles of each panel to determine actual Panel Width. With astragals, overlapping, etc., the
actual Panel Width not only varies with position of panel in a configuration, but the inside and outside surface widths of each
stile may be different.
For each configuration, the Frame Width (FW) is the sum of the nominal Panel Width (PW) x the number of panels + a number
(N) which is the sum of the side jamb dimensions and dimensions of space between panels in excess of the nominal Panel Width
as shown in the Cross-Section Details. This can be used as a guideline. Contact NanaWall for exact calculation for particular unit.
Frame Height (FH)
Raised Sill : Low Profile Saddle Sill / Flush Sill:
Alternate Flush Sill:
WA66/o top hung System
Frame Height = Panel Height + 119 (4 11/16”) = Clear Opening Height + 174 (6 7/8”)
Frame Height = Panel Height + 139 (5 1/2”) = Clear Opening Height + 157 (6 3/16”)
Frame Height = Panel Height + 129 (5 1/8”) = Clear Opening Height + 151 (5 15/16”)
Frame Height (FH)
WA66/u Floor Supported System
Raised Sill :
Frame Height = Panel Height + 103 (4 1/16”) = Clear Opening Height + 157 (6 3/16”)
Low Profile Saddle Sill / Flush Sill: Frame Height = Panel Height + 121 (4 3/4”) = Clear Opening Height + 140 (5 1/2”)
Frame Widths for Different Configurations with Majority of Panels Folding to Right (and their Mirror Image Configurations
with Majority of Panels Folding to Left). See Maximum Size Charts for size limits.
Please note that widths for units with unhinged panels or angle turns will be different.
Model 1R
Frame Width = 1 x Panel Width + 136 = 1 x Panel Width + 5 3/8””
Model 1L1R
Frame Width = 2 x Panel Width + 149 = 2 x Panel Width + 5 7/8”
Model 2R
Frame Width = 2 x Panel Width + 178 = 2 x Panel Width + 7”
Model 3R
Frame Width = 3 x Panel Width + 162 = 3 x Panel Width + 6 3/8”
Model 1L2R
Frame Width = 3 x Panel Width + 222 = 3 x Panel Width + 8 3/4”
Model 4R
Frame Width = 4 x Panel Width + 204 = 4 x Panel Width + 8 1/16”
Model 1L3R
Frame Width = 4 x Panel Width + 175 = 4 x Panel Width + 6 7/8”
Model 2L2R
Frame Width = 4 x Panel Width + 264 = 4 x Panel Width + 10 3/8”
Model 5R
Frame Width = 5 x Panel Width + 188 = 5 x Panel Width + 7 3/8”
Model 2L3R, Model 1L4R
Frame Width = 5 x Panel Width + 248 = 5 x Panel Width + 9 3/4”
Model 3L3R, Model 1L5R
Frame Width = 6 x Panel Width + 201 = 6 x Panel Width + 7 15/16”
Model 2L4R
Frame Width = 6 x Panel Width + 290 = 6 x Panel Width + 11 7/16”
Model 6R
Frame Width = 6 x Panel Width + 23 = 6 x Panel Width + 9 1/16”
Model 1L6R, Model 2L5R, 3L4R
Frame Width = 7 x Panel Width + 274 = 7 x Panel Width + 10 13/16”
Model 4L4R, Model 2L6R
Frame Width = 8 x Panel Width + 316 = 8 x Panel Width + 12 7/16”
Model 3L5R
Frame Width = 8 x Panel Width + 227 = 8 x Panel Width + 8 15/16”
Model 4L5R, Model 3L6R
Frame Width = 9 x Panel Width + 300 = 9 x Panel Width + 11 13/16”
Model 5L5R
Frame Width = 10 x Panel Width + 253 = 10 x Panel Width + 9 15/16”
Model 4L6R
Frame Width = 10 x Panel Width + 342 = 10 x Panel Width + 13 7/16”
Model 5L6R
Frame Width = 11 x Panel Width + 326 = 11 x Panel Width + 12 13/16”
Model 6L6R
Frame Width = 12 x Panel Width + 368 = 12 x Panel Width + 14 1/2”
18
INWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Drawings are shown with 3 1/16” (78 mm) stile and rail widths and 2 5/8” (66 mm) deep profiles. Nominal 3 3/4” (95 mm)
and 4 3/4” (120 mm) stile and rail widths are available as well as 3 1/16” (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing.
EXTERIOR
Detail 1.0
Head Jamb WD66/o
(top hung)
INTERIOR
Detail 22.0
Low Profile Saddle Sill
WD66/o (top hung)
(For resistance against wind
driven rain, drain connections
by others are necessary. Sill
is not centered with other
frame components.)
Frame Height
FFH
EXTERIOR
Detail 25.0
Thermally Broken Flush Sill
WD66/o (top hung)
INTERIOR
(No rating against wind driven rain)
EXTERIOR
INTERIOR
FFH
INTERIOR
EXTERIOR
FFH
Detail 2.0
Raised Sill (higher weather
performance sill) WD66/o
(top hung)
Detail 26.0
Alternate Flush Sill WD66/o (top hung)
(No Rating against wind driven rain. Sill is not
thermally broken)
19
Note: For ADA compliance in commercial projects, a gasket to cover the channel in the
sill at swing panels is provided for both the Low Profile Saddle Sill and Flush Sill.
INWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Drawings are shown with 3 1/16” (78 mm) stile and rail widths and 2 5/8” (66 mm) deep profiles. Nominal 3 3/4” (95 mm)
and 4 3/4” (120 mm) stile and rail widths are available as well as 3 1/16” (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing.
Detail 12.0
Head Jamb WD66/u (floor supported)
EXTERIOR
INTERIOR
Detail 14.0
Flush Sill WD66/u
(floor supported)
(No rating against wind
driven rain).
FFH
INTERIOR
Detail 42.0
Raised Sill (higher weather performance sill)
WD66/u (floor supported)
Detail 13.0
Low Profile Saddle
Sill WD66/u
(No rating against
wind driven rain.)
1/2” [12]
Frame Height
EXTERIOR
FFH
EXTERIOR
INTERIOR
20
INWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Drawings are shown with 3 1/16” (78 mm) stile and rail widths and 2 5/8” (66 mm) deep profiles. Nominal 3 3/4” (95 mm)
and 4 3/4” (120 mm) stile and rail widths are available as well as 3 1/16” (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing.
Detail 3R.0 Panel hinged at left side jamb
Detail 3.0 Panel hinged at right side jamb
EXTERIOR
INTERIOR
EXTERIOR
Detail 4.0
Swing panel with locking at
left side jamb
INTERIOR
EXTERIOR
Detail 4R.0
Swing Panel with locking
at right side jamb
INTERIOR
21
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
INWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Drawings are shown with 3 1/16” (78 mm) stile and rail widths and 2 5/8” (66 mm) deep profiles. Nominal 3 3/4” (95 mm)
and 4 3/4” (120 mm) stile and rail widths are available as well as 3 1/16” (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing.
EXTERIOR
Detail 5.0
Panel with running
carriage set meeting
left side jamb
INTERIOR
EXTERIOR
Detail 5R.0
Panel with running
carriage set meeting
right side jamb
INTERIOR
EXTERIOR
Detail 7C.0 and 7RC.0
Folding panels with
running carriage set
INTERIOR
22
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
INWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Drawings are shown with 3 1/16” (78 mm) stile and rail widths and 2 5/8” (66 mm) deep profiles. Nominal 3 3/4” (95 mm) and 4 3/4”
(120 mm) stile and rail widths are available as well as 3 1/16” (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing.
EXTERIOR
7.0 and 7R.0
Folding panels with locking
INTERIOR
handle for 7R.0
handle for 7.0
EXTERIOR
Detail 8.0
Two swing panels with
locking. Left panel
opening first
INTERIOR
EXTERIOR
Detail 8R.0
Two swing panels with
locking. Right panel
opening first
INTERIOR
23
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
INWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Drawings are shown with 3 1/16” (78 mm) stile and rail widths and 2 5/8” (66 mm) deep profiles. Nominal 3 3/4” (95 mm) and 4 3/4”
(120 mm) stile and rail widths are available as well as 3 1/16” (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing.
Detail 9.0 and 9R.0 Meeting of panels folding to opposite side (no swing panel). Running carriage sets on both panels
EXTERIOR
INTERIOR
Detail 10.0
Meeting of swing
panel with locking
on left and folding
panel with running
carriage set
on right
EXTERIOR
INTERIOR
Detail 10R.0 Meeting of swing panel with locking on right and folding panel with running carriage set on left
EXTERIOR
INTERIOR
24
OUTWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Drawings are shown with 3 1/16” (78 mm) stile and rail widths and 2 5/8” (66 mm) deep profiles. Nominal 3 3/4” (95 mm) and 4
3/4” (120 mm) stile and rail widths are available as well as 3 1/16” (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing.
EXTERIOR
INTERIOR
Detail 1.1
Head Jamb WD66/o
(top hung)
Frame Height
FFH
EXTERIOR
Detail 22.1
Low Profile Saddle Sill WD66/o (top hung)
INTERIOR
(For resistance against wind driven rain, drain connections by others
necessary. Sill is not centered with other frame components.)
Detail 25.1
Thermally Broken Flush Sill
WD66/o (top hung)
(No rating against wind driven rain)
Detail 26.1
Alternate Flush Sill WD66/o (top hung)
(No rating against wind driven rain. Sill is not
thermally broken.)
EXTERIOR
INTERIOR
FFH
Detail 2.1
Raised Sill (higher weather
performance sill) WD66/o
(top hung)
Note: For ADA compliance in commercial projects, a
gasket to cover the channel in the sill at swing panels is
provided for both the Low Profile Saddle Sill and Flush Sill.
FFH
25
OUTWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Drawings are shown with 3 1/16” (78 mm) stile and rail widths and 2 5/8” (66 mm) deep profiles. Nominal 3 3/4” (95 mm) and 4
3/4” (120 mm) stile and rail widths are available as well as 3 1/16” (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing.
EXTERIOR
INTERIOR
Detail 12.1
Head Jamb WD66/o
(floor supported)
Detail 14.1
Flush Sill WD66/u
floor supported
(No rating against wind
driven rain.)
FFH
INTERIOR
Detail 42.1
Raised Sill (higher weather performance
sill) WD66/u (floor supported)
EXTERIOR
INTERIOR
Detail 13.1
Low Profile Saddle
Sill WD66/u
(No rating against wind
driven rain.)
1/2” [12]
Frame Height
EXTERIOR
FFH
26
OUTWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Drawings are shown with 3 1/16” (78 mm) stile and rail widths and 2 5/8” (66 mm) deep profiles. Nominal 3 3/4” (95 mm)
and 4 3/4” (120 mm) stile and rail widths are available as well as 3 1/16” (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing.
Detail 3R.1 Panel hinged at left side jamb
Detail 3.1 Panel hinged at right side jamb
EXTERIOR
INTERIOR
EXTERIOR
Detail 4.1
Swing panel with locking
at left side jamb
INTERIOR
EXTERIOR
INTERIOR
Detail 4R.1
Swing panel with locking at
right side jamb
27
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
OUTWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Drawings are shown with 3 1/16” (78 mm) stile and rail widths and 2 5/8” (66 mm) deep profiles. Nominal 3 3/4” (95 mm)
and 4 3/4” (120 mm) stile and rail widths are available as well as 3 1/16” (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing.
Detail 5.1
Panel with running
carriage set meeting
left side jamb
Detail 5R.1
Panel with running
carriage set meeting
right side jamb
EXTERIOR
INTERIOR
EXTERIOR
INTERIOR
Detail 7RC.1
and 7C.1
Folding panel with
running carriage set
28
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
OUTWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Drawings are shown with 3 1/16” (78 mm) stile and rail widths and 2 5/8” (66 mm) deep profiles. Nominal 3 3/4” (95 mm)
and 4 3/4” (120 mm) stile and rail widths are available as well as 3 1/16” (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing.
Detail 7.1 and 7R.1
Folding panels with locking
handle for 7R.1
Detail 8.1
Two swing panels
with locking. Left
panel opening first.
handle for 7.1
EXTERIOR
INTERIOR
EXTERIOR
INTERIOR
Detail 8R.1
Two swing panels with
locking. Right panel
opening first.
29
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
OUTWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Drawings are shown with 3 1/16” (78 mm) stile and rail widths and 2 5/8” (66 mm) deep profiles. Nominal 3 3/4” (95 mm)
and 4 3/4” (120 mm) stile and rail widths are available as well as 3 1/16” (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing.
Detail 9.1 and 9R.1 Meeting of panels folding to opposite side (no swing panel) running carriages set on both panels
EXTERIOR
INTERIOR
Detail 10.1 Meeting of swing panel with locking on left and folding panel with running carriage set on right
EXTERIOR
INTERIOR
Detail 10R.1 Meeting of swing panel with locking on right and folding panel with running carriage set on left
EXTERIOR
INTERIOR
30
SUGGESTED TYPICAL INSTALLATION | WD66
All Cross Sectional Views Are Half Size
Head Jamb (top hung)
INSTALLATION NOTES
Suggested Typical Installation drawings shown are very
general and may not be suitable for any particular installation.
Product placement, fasteners, flashing, waterproofing,
sealant, trim and other details for specific surrounding
conditions must be properly designed and provided by
others.
INSTALLATION CONSIDERATIONS
EXTERIOR
INTERIOR
Frame Height
Rough Opening From Subfloor
The approximate weight of a panel with double-glazing is
5.5 - 8 lbs/ft2 (27 - 39 kg/m2), and with triple glazing is 8
lbs/ft2 (39 kg/m2). The vertical structural deflection of the
header should be the lesser of L/720 of the span and ¼” (6
mm) under full loads. Although for floor supported systems,
there is no vertical load on the header from the panels,
structural support for lateral loads (both windload and when
the panels are stacked open) must be provided. See “PreInstallation Preparation and Installation Guidelines” in the
General Introduction. An owner’s manual with installation
instructions is available upon request.
Standard Raised Sill (top hung)
(higher weather performance sill)
It is recommended that all building dead loads be applied
to the header prior to installing the NanaWall. If so and if a
reasonable amount of time has been allowed for the effect
of this dead load on the header, then only the building’s live
load can be used to meet the above requirements of L/720
or 1/4” (6 mm). If not, both the dead and live loads need to
be considered. For the floor supported WD66u, please note
that there is no vertical load on the header.
Panel Hinged At Right Side Jamb
EXTERIOR
INTERIOR
31
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
SUGGESTED TYPICAL INSTALLATION | WD66
Standard Window Sill (top hung)
EXTERIOR
All Cross Sectional Views Are Half Size
Raised Sill (higher weather performance sill)
with Sub-Sill Installation (top hung)
INTERIOR
EXTERIOR
Alternate - Raised Sill (higher weather performance sill)
Recessed Installation (top hung)
EXTERIOR
INTERIOR
INTERIOR
INSTALLATION NOTES
Suggested Typical Installation
drawings shown are very general
and may not be suitable for any
particular installation. Product
placement, fasteners, flashing,
waterproofing,
sealant,
trim
and other details for specific
surrounding conditions must be
properly designed and provided
by others.
See Installation Considerations on
page 31.
32
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
SUGGESTED TYPICAL INSTALLATION | WD66
Low Profile Saddle Sill* (top hung)
(Sill not centered with other frame components)
EXTERIOR
INTERIOR
All Cross Sectional Views Are Half Size
INSTALLATION NOTES
Suggested Typical Installation drawings shown
are very general and may not be suitable for
any particular installation. Product placement,
fasteners, flashing, waterproofing, sealant,
trim and other details for specific surrounding
conditions must be properly designed and
provided by others..
*FOR LOW PROFILE SADDLE SILL
(WD66/o).
For resistance against wind driven rain, the
following is recommended by others
1. Remove the gasket covering the inner
channel.
2. Provide necessary weepholes at the bottom
of the channels and on the outside face of
the sill.
3. Make necessary drain connections.
Ask NanaWall for a detailed drawing.
Altenative Flush Sill (top hung)
Flush Sill (top hung)
Notes: For ADA compliance in commercial projects, a gasket to cover the channel in the sill at swing panels is provided
See Installation Considerations on Page 20
33
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
SUGGESTED TYPICAL INSTALLATION | WD66
All Cross Sectional Views Are Half Size
INSTALLATION NOTES
Head Jamb (top hung)
Suggested Typical Installation drawings shown are very general
and may not be suitable for any particular installation. Product
placement, fasteners, flashing, waterproofing, sealant, trim
and other details for specific surrounding conditions must be
properly designed and provided by others.
Installation Considerations
It is recommended that all building dead loads be applied to the
header prior to installing the NanaWall. If so and if a reasonable
amount of time has been allowed for the effect of this dead load
on the header, then only the building’s live load can be used to
meet the above requirements of L/720 or 1/4” (6 mm). If not, both
the dead and live loads need to be considered. For the floor
supported WD66u, please note that there is no vertical load on
the header.
Unit Height
Rough Opening From Subfloor
The approximate weight of a panel with double-glazing is 5.5
- 8 lbs/ft2 (27-39 kg/m2) and with triple glazing is 8 lbs/ft2 (39
kg/m2). The vertical structural deflection of the header should
be the lesser of L/720 of the span and ¼” (6 mm) under full
loads. Although for floor supported systems, there is no vertical
load on the header from the panels, structural support for
lateral loads (both windload and when the panels are stacked
open) must be provided. See “Pre-Installation Preparation and
Installation Guidelines” in the General Introduction. An owner’s
manual with installation instructions is available upon request.
Standard Sill (top hung)
EXTERIOR
INTERIOR
EXTERIOR
INTERIOR
Panel Hinged
at Right Side Jamb
Note: For ADA compliance in commercial projects, a gasket
to cover the channel in the sill at swing panels is provided
34
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
OTHER SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
Other Section Details
Typical Mullion Profile
(Note: Different mullion widths are available)
Typical Higher Bottom Rail
Typical Simulated Divided Lites Muntins with
Spacers Between Insulated Glass (SDL)
Typical Rail with Single 1/4” Glass
35
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
INWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
WD66 with 3 1/16" (78 mm) profile
Detail 12.0
(78) Floor Supported
Head Jamb
EXTERIOR
INTERIOR
EXTERIOR
INTERIOR
Detail 14.0
(78) Floor Supported
Flush sill
(No rating against wind
driven rain)
FFH
INTERIOR
Frame Height
EXTERIOR
Detail 42.0
(78) Floor Supported
Higher Weather
Performance (Raised) Sill
Detail 13.0
(78) Low Profile Saddle
Sill WD66/u
(No rating against wind driven rain.)
FFH
36
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
INWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
WD66 with 3 1/16" (78 mm) profile
Note: Reverse or mirror details are not shown
EXTERIOR
EXTERIOR
INTERIOR
INTERIOR
Detail 3.0
Panel hinged at right
side jamb
Detail 4.0
Swing panel with locking
at left side jamb
EXTERIOR
Detail 5.0
Panel with running
carriage set meeting
left side jamb
INTERIOR
37
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
INWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
WD66 with 3 1/16" (78 mm) profile
Note: Reverse or mirror details are not shown
EXTERIOR
Detail 7.0
Right folding panel
with locking
INTERIOR
EXTERIOR
Detail 7C.0
Folding panel with
running carriage set
INTERIOR
EXTERIOR
Detail 8.0
Two swing panels
with locking: left panel
opening first
INTERIOR
38
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
INWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
WD66 with 3 1/16" (78 mm) profile
Note: Reverse or mirror details are not shown
Detail 9.0 Meeting of panels folding to opposite sides (no swing panel), running carriage sets on both panels
EXTERIOR
INTERIOR
Detail 10.0 Meeting of swing panel with locking on left and foldiong panel with running carriage set on right
EXTERIOR
INTERIOR
39
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
OUTWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
WD66 with 3 1/16" (78 mm) profile
Detail 12.1
(78) Floor
Supported
Head Jamb
EXTERIOR
INTERIOR
EXTERIOR
INTERIOR
Detail 14.1
Floor Supported
(78) Flush sill
(No rating against
wind driven rain)
INTERIOR
Frame Height
EXTERIOR
EXTERIOR
INTERIOR
Detail 42.1
Floor Supported
(78) Higher Weather
Perfromance (Raised) Sill
Detail 13.1
Low Profile Saddle Sill
WD66/u
(No rating against wind
driven rain.)
FFH
40
OUTWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
WD66 with 3 1/16" (78 mm) profile
Note: Reverse or mirror details are not shown
Detail 3.1 Panel hinged at right side jamb
Detail 4.1 Swing panel with locking at left side jamb
EXTERIOR
EXTERIOR
INTERIOR
INTERIOR
Detail 5.1 Panel with running carriage set meeting left side jamb
EXTERIOR
INTERIOR
41
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
OUTWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
WD66 with 3 1/16" (78 mm) profile
Note: Reverse or mirror details are not shown
EXTERIOR
Detail 7.1
Right folding panel
with locking
INTERIOR
EXTERIOR
Detail 7C.1
Folding panel with
running carriage set
INTERIOR
EXTERIOR
Detail 8.1
Two swing panels
with locking: left panel
opening first
INTERIOR
42
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
OUTWARD OPENING SECTION DETAILS | WD66
All Cross Sectional Views Are Half Size
WD66 with 3 1/16" (78 mm) profile
Note: Reverse or mirror details are not shown
Detail 9.1 Meeting of panels folding to opposite sides (no swing panel) running carriage sets on both panels
EXTERIOR
INTERIOR
Detail 10.1 Meeting of swing panel with locking on left and folding panel with running carriage set on right
EXTERIOR
INTERIOR
43
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com
DESIGN WINDLOAD CHART FOR 2 5/8” (66 MM) THICK PROFILE | WD66
(Derived From Comparative Analysis)
Test Unit Size: 9’2” W x 7’ 10.5” H
(3 panels)
135
Inswing Unit:
Negative Pressure
125
Outswing Unit:
Positive Pressure
120
130
115
Please note that some jurisdictions
may limit the use of these charts or
may not accept them at all. Design
pressures and/or sizes may be
restricted to what was tested. For
Florida approved products, please
see detailed FL Evaluation Report for
restrictions.
110
105
100
95
Please also note that chart is only
applicable for units with referenced
NanaWall supplied locking.
80
75
70
60
1’11’
55
50
2’3”
45
2’7”
40
2’11”
35
PANEL WIDTH
65
Unit Width Divided by Number of Panels
85
ALLOWABL E DESIGN WIND LOADING - PSF
Allowable Design Wind Loading - PSF
90
3’3”
30
3’7”
25
20
15
10
5
0
6’0”
6’6”
7’0”
7’6”
8’0”
8’6”
9’0”
9’6” 10’0”
Panel
PANELHeight
HEIGHT
SeeMaximum
Maximum Frame
forfor
Possible
Sizes Sizes
See
FrameSize
SizeChart
Chart
Possible
44
DESIGN WINDLOAD CHART FOR 2 5/8” (66 MM) THICK PROFILE | WD66
(Derived From Comparative Analysis)
Test Unit Size: 9’2” W x 7’ 10.5” H
(3 panels)
135
Inswing Unit:
Positive Pressure
125
Outswing Unit:
Negative Pressure
120
130
115
Please note that some jurisdictions
may limit the use of these charts or
may not accept them at all. Design
pressures and/or sizes may be
restricted to what was tested. For
Florida approved products, please
see detailed FL Evaluation Report for
restrictions.
110
105
100
95
Please also note that chart is only
applicable for units with referenced
NanaWall supplied locking.
80
75
70
PANEL WIDTH
65
60
55
50
45
40
1’11’
35
Unit Width Divided by Number of Panels
85
ALLOWABL E DESIGN WIND LOADING - PSF
Allowable Design Wind Loading - PSF
90
2’3”
30
2’7”
25
2’11”
3’3”
20
3’7”
15
10
5
0
6’0”
6’6”
7’0”
7’6”
8’0”
8’6”
9’0”
9’6” 10’0”
PANEL Height
HEIGHT
Panel
SeeSee
Maximum
ChartforforPossible
Possible
Sizes
MaximumFrame
Frame Size
Size Chart
Sizes
45
46
SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE
©2016 Nana Wall Systems, Inc.
www.nanawall.com