CRSX-CRXH stainless steel enclosures for permanent protection
Transcription
CRSX-CRXH stainless steel enclosures for permanent protection
CRSX-CRXH stainless steel enclosures for permanent protection 4 1 2 5 7 6 3 2/12 02_008_013.indd 12 2/4/08 12:33:40 New range: c Glazed door. c Double door. c 2 stainless steel qualities: 304L and 316L. c 2 types of finish: brushed and microbeading. c Microbeading on request. 1 2 c Stainless steel wall fixing brackets 304 or 316L. c 4 drillings in rear of enclosure for mounting directly on machine. c Stainless steel hinges. c Reinforcement frame on the door. 3 4 5 Watertightness: c Degree of protection IP66 (IEC 60529): total protection agains duar & water jets. c Polyurethane or neoprene gasket. c Front gutterprofile. c Three-point locking for double door. c Stainless steel accessories: canopies, wall-fixing brackets. c Accessories from the standard offer: chassis, internal door, modular chassis, moveable plate support. 6 7 c Vertical support perforated rails to allow door mounted equipment. c Reversible door opening angle 120º. c Wide range of locks with 100% stainless steel inserts. 2/13 02_008_013.indd 13 2/4/08 12:33:45 Stainless steel enclosures IP66 (EN 60529) CRSX CRSX 54/200 Himel stainless steel enclosures are particularly suitable for corrosive environments and installations requiring strict hygiene. They are ideal for the chemical, petrochemical, agrifood and pharmaceutical industries, amongst others. CRSX 54/200 KT c Two types of material are available: v AISI 304L with brushed finish. v AISI 316L with microbeading finish. c Two enclosure versions are available: v Plain door. v Glazed door, Securit glass 4 mm thick. c For 304L microbeading version, please consult our office. c Degree of protection IP66 for all single and glazed door enclosures, IP55 for double door enclosures, in accordance with IEC 60259. c Resistance to external mechanical impacts: v IK10 for plain door enclosures. v IK08 for glazed door enclosures. c 1-piece body (cross structure). Gutter shaped front profile. c Two perforated vertical door reinforcement profiles (on models from 600 mm high) with Ø 4.25 mm holes on 25 mm pitch to assemble equipment. c Door reinforcement frame (from 1000 mm high), section 20 × 15 mm, with Ø 5 mm holes on 25 mm pitch. c Standard door closure by 3 mm double bar lock (chromed zamack). c 2 point locking from 500 mm high or 3 point locking for double door enclosure. 2/14 02_014_015.indd 14 17/3/08 11:03:12 Stainless steel enclosures IP66 (EN 60529) CRSX-CRXH c Stainless steel hinges screw fixed to the body of enclosure. To simplify removal of door for reversing its opening direction. Door opening angle: 120°. c Polyurethane gasket (or neoprene in 316L). c Equipotent connection assured by M6 × 16 screws on body and on door (to be ordered separately). c Four holes for fixing directly to wall or by means of fixing lugs (to be ordered separately), blanked off by sealing plugs. c Not perforated on body. Certifications: c EN 50298. c UL50 and Bureau Veritas certification. TABLE OF MODELS, DIMENSIONS AND REFERENCES External dimensions (mm) Number of locks 304L Scotch-brite® finish Number of doors 316L abrasive blasted (micro-sphere blasted) reference Fig. Height (A) Width (B) Depth (C) 300 200 150 1 1 1 CRSX 32/150 CRXH 32/150 300 250 150 1 1 1 CRSX 3025/150 CRXH 3025/150 300 300 150 1 1 1 CRSX 33/150 CRXH 33/150 400 300 150 1 1 1 CRSX 43/150 400 300 200 1 1 1 CRSX 43/200 400 400 200 1 1 1 CRSX 44/200 400 600 200 1 1 1 CRSX 46/200 500 400 200 2 1 2** CRSX 54/200 CRSX 54/200 KT CRXH 54/200 600 400 200 2 1 2 CRSX 64/200 CRSX 64/200 KT CRXH 64/200 600 600 250 2 1 2 CRSX 66/250 700 500 250 2 1 2 CRSX 75/250 CRSX 75/250 KT CRXH 75/250 800 600 250 2 1 2 CRSX 86/250 CRSX 86/250 KT CRXH 86/250 800 800 300 2 1 2 CRSX 88/300 1000 800 300 2 1 3 CRSX 108/300 1000 1000 300 * 2 4 CRSX 1010/300 CRXH 1010/300 1200 800 300 2 1 3 CRSX 128/300 CRXH 128/300 1200 1000 300 * 2 4 CRSX 1210/300 CRXH 1210/300 Plain door Transparent door CRXH 43/150 CRSX 43/200 KT CRXH 43/200 CRXH 44/200 CRXH 46/200 CRXH 66/250 CRXH 88/300 CRSX 108/300 KT CRXH 108/300 * Three-point lock system. ** Without door reinforcement frame. ACCESSORY SELECTION TABLE External dimensions (mm) Mounting plates Internal door Height (A) Width (B) Depth (C) Metal Insulated 300 200 150 MM-32 300 250 150 MM-3025 300 300 150 400 300 400 DLM chassis Moveable plate supports Canopies Perforated Universal MB-32 MF-32 MR-32 - - - TX-2015 MB-3025 MF-3025 MR-3025 - - - TX-2515 MM-33 MB-33 MF-33 MR-33 - - - TX-3015 150 MM-43 MB-43 MF-43 MR-43 PIN-43 DLM-24 - 300 200 MM-43 MB-43 MF-43 MR-43 PIN-43 DLM-24 SDCR-200 TX-3020 400 400 200 MM-44 MB-44 MF-44 MR-44 - - SDCR-200 TX-4020 400 600 200 MM-46 MB-46 MF-46 MR-46 - - SDCR-200 TX-6020 500 400 200 MM-54 MB-54 MF-54 MR-54 PIN-54 DLM-48 SDCR-200 TX-4020 600 400 200 MM-64 MB-64 MF-64 MR-64 PIN-64 DLM-48P SDCR-200 TX-4020 600 600 250 MM-66 MB-66 MF-66 MR-66 DLM-84P SDCR-250 TX-6025 700 500 250 MM-75 MB-75 MF-75 MR-75 PIN-75 DLM-66/DLM-88 SDCR-250 TX-5025 800 600 250 MM-86 MB-86 MF-86 MR-86 PIN-86 DLM-84/DLM-112 SDCR-250 TX-6025 800 800 300 MM-88 MB-88 MF-88 MR-88 - 1000 800 300 MM-108 MB-108 MF-108 MR-108 PIN-108 1000 1,000 300 MM-1010 MB-1010 MF-1010 MR-1010 - 1200 800 300 MM-128 MB-128 MF-128 MR-128 PIN-128 1200 1,000 300 MM-1210 MB-1210 MF-1210 MR-1210 - - - TX-3015 SDCR-300 TX-8030 SDCR-300 TX-8030 - SDCR-300 TX-10030 - SDCR-300 TX-8030 - SDCR-300 TX-10030 DLM-240 2/15 02_014_015.indd 15 17/3/08 11:03:17 Stainless steel enclosures IP66 (EN 60529) CRSX-CRXH Dimensions (mm) FIG. 1 FIG. 2 B C 21 External dimensions (mm) B C B-133 A-5 A-75 A-50 A-44 83 A A-5 B-44 83 A-75 10 A-50 A A-125 A-44 114 40 Height (A) 21 40 114 B-44 B-50 B-75 B - 50 B - 75 800 B - 76,4* B-5 B-5 B-5 *The KT transparent doors do not include reinforcement profile. FIG. 3 Width (B) Depth (C) 300 200 150 300 250 150 300 300 150 400 300 150 400 300 200 400 400 200 400 600 200 500 400 200 600 400 200 600 600 250 700 500 250 800 600 250 800 800 300 1000 800 300 1000 1000 300 1200 800 300 1200 1000 300 FIG. 4 B C B A-125 114 40 10 83 B-44 A A-75 A-50 A-44 A A A-44 25 B-145 114 B-44 B-50 B-50 B-75 B-75 B-136 B-5 418,5/518,5** 372/472** B-5 *Reinforcement profile for 1,200 mm wide models 2/16 02_016.indd 16 27/2/08 10:46:13 CRSX-CRXH Composition accessories Wall mounting kit 4-piece stainless steel wall-fixing set, not included in standard supply. Type of stainless steel Reference PFCX 304 PFC2X 316L 25 29 42.5 9 21 Ø13.4 7.5 25 Canopies c Made of 304L stainless steel, Scotch-brite® finish. c Ready to be coupled directly to the enclosures. For enclosures with dimensions (mm) Reference A Width B C D E Depth TX-2015 200 150 205 183 51 120 - TX-2515 250 150 205 183 51 120 - TX-3015 300 150 305 183 51 220 - TX-3020 300 200 305 233 51 220 70 TX-4020 400 200 405 233 70 320 70 TX-5025 500 250 505 283 70 420 120 600 200 605 233 70 520 70 TX-6025 600 250 605 283 70 520 120 TX-8030 800 300 805 333 70 720 170 TX-10030 1000 300 1005 333 70 920 170 53 E B TX-6020 C D A 2/17 02_017_023.indd 17 17/3/08 11:13:45 CRSX-CRXH Composition accessories Locks for CRSX and CRXH enclosures Standard double bar lock, with latch and fixing screw in chrome zamac operated using key LDB3 (conforming to DIN 43668) included in the standard supply. Reference STDN/CSX. Specifications STDN/CSX Type of key operation ref. Reference 6 mm stainless steel square lock LC-7 TC 6/CSX 7 mm stainless steel square lock LC-7 TC 7/CSX LT-8 TT 8/CSX ∆ 8 mm side stainless steel triangle lock TC 6/CSX TC 7/CSX TT 8/CSX Complete 405 key lock CL/CSX Stainless steel 304 double bar lock STD/CXH Chrome zamac double bar lock STD/CSX STD/CSX STD/CXH CL/CSX Three-point locks for CRSX and CRXH enclosures Chrome zamac standard double-bar lock for double door models. c Operated by: v LDB5 key (conforming to DIN 43668). TRANSFORMATION OF THE STANDARD LOCK TO STANDARDISED VARIATIONS ON ENCLOSURES WITH THREE-POINT LOCKS Specifications TC... TT... Type of key operation ref. Reference 6 mm square lock LC-7 TC 6/ML 7 mm square lock LC-7 TC 7/ML 8 mm square lock LC-8 TC 8/ML ∆ 7 mm side triangle lock LT-8 TT 7/ML ∆ 8 mm side triangle lock LT-8 TT 8/ML Handle lock TS/ML Key operated handle lock TL/ML TS/ML TL/ML 2/18 02_017_023.indd 18 17/3/08 11:13:46 CRSX-CRXH Composition accessories Internal doors Internal door designed to be coupled directly to the enclosure or to the moveable SDCR supports. Allows for placement of a mounting plate, making it depth adjustable. Finished with texturised epoxy-polyester paint, colour RAL-7032. From 800 mm, the vertical reinforcement profiles are included. 2 1 27 D A 40 CRSX 54/200 + PIN 54 32 23 23 min = 30 10 G E H C I C 1 PIN internal door fixed directly to the enclosure. 2 PIN internal door fixed to the moveable SDCR support. In this case, both the internal door and the mounting plate may be depth adjustable. For enclosures dimensions (mm) Reference Height (A) D E G H I (min.) 51 Width (B) 400 300 PIN 43 349 241 208 32 500 400 PIN 54 449 341 308 32 51 600 400 PIN 64 549 341 308 32 51 700 500 PIN 75 649 441 408 32 51 800 600 PIN 86 749 541 508 32 51 1000 600 PIN 106 949 541 508 32 51 1000 800 PIN 108 949 741 708 32 51 1200 800 PIN 128 1149 741 708 32 52 For enclosures with a transparent door, H is reduced 4 mm. 2/19 02_017_023.indd 19 17/3/08 11:14:10 CRSX-CRXH Composition accessories Doors in 304L stainless steel Doors made of 304L stainless steel, Scotch-brite® finish. Doors made of 304L stainless steel, Scotch-brite® finish. External dimensions (mm) Height (A) Width (B) Reference 300 200 PCRSX-32 300 250 PCRSX-3025 300 300 PCRSX-33 400 300 PCRSX-43 400 400 PCRSX-44 400 600 PCRSX-46 500 400 PCRSX-54 600 400 PCRSX-64 600 600 PCRSX-66 700 500 PCRSX-75 800 600 PCRSX-86 800 800 PCRSX-88 1000 800 PCRSX-108 1200 800 PCRSX-128 Plan pocket PP-A models made of PVC in grey RAL-7035. c Fixed with adhesive tape or screws. For holding DIN A4 or A5-sized plans. Reference A4 PP-A4 A5 PP-A5 234 174 Plan size 188 Ref.: PP-A5 22 278 40 Ref.: PP-A4 2/20 02_017_023.indd 20 17/3/08 11:14:16 CRSX-CRXH Composition accessories Earthing connections CTI: used to guarantee the electrical connection between the door and the body of the enclosure or between the body and the mounting plate. CTI CTAF: guarantees the earthing connection for high frequencies, avoiding the interference currents that are produced at high frequencies. Made of tinned copper. Reference CTAF Length mm Width mm Section mm2 Material CTI 17/6 170 6 Copper wires with tinned copper terminal CTI 17/10 170 10 Copper wires with tinned copper terminal CTI 22/6 220 6 Copper wires with tinned copper terminal CTI 22/10 220 10 Copper wires with tinned copper terminal CTI 22/25 220 25 Copper wires with tinned copper terminal CTI 41/10 410 10 Copper wires with tinned copper terminal CTI 41/25 410 25 Copper wires with tinned copper terminal CTAF 15/16 155 20 16 Tinned copper wires and terminal CTAF 20/25 200 21 25 Tinned copper wires and terminal CTAF 25/25 200 26 25 Tinned copper wires and terminal CTAF 20/50 200 40 50 Tinned copper wires and terminal 2/21 02_017_023.indd 21 17/3/08 11:14:31 CRSX-CRXH Mounting accessories Mounting plates A complete range of mounting plates comprised of four versions able to provide all the mountings required for this installation system. c Metal plates of galvanised steel. c Bakelite insulated plates. c Perforated plates made of galvanised sheet steel with 3.6 mm Ø holes, 12.5 mm apart. c Universal plates for fast fixing of equipment, made of steel zinc dichromate. The location of the holes, combined with the position of the nuts, covers all the fixing centres. Insulated Metal Insulated S Perforated S E P P P 10,5 Universal S 12,5 12,5 10,5 A-75 ø3,6 ø8,5 12,5 25 12,5 20 25 25 Universal 12,5 A-75 ø6,5 Perforated 15 D Metal 25 12,5 For use with CRSX enclosures Insulated Metal Perforated Universal P Height (A) Width (B) Reference Thickness Weight (mm) (kg) Reference 12,5 B-75 B-75 Thickness Weight (kg) (mm) Reference S Thickness Weight (kg) (mm) Reference D E 300 200 MM-32 2 0.5 MB-32 4 0.2 MF-32 2 0.5 265 150 MR-32 255 154 300 250 MM-3025 2 0.6 MB-3025 4 0.3 MF-3025 2 0.6 265 200 MR-3025 253 228 300 300 MM-33 2 1.2 MB-33 4 0.5 MF-33 2 1.1 265 250 MR-33 255 251 400 300 MM-43 2 1.6 MB-43 4 0.5 MF-43 2 1.5 365 250 MR-43 348 251 400 400 MM-44 2 2.2 MB-44 4 0.7 MF-44 2 2.1 365 350 MR-44 345 351 400 600 MM-46 2 3.1 MB-46 4 1.1 MF-46 2 3 365 550 MR-46 345 551 500 400 MM-54 2 2.5 MB-54 4 0.9 MF-54 2 2.4 465 350 MR-54 450 351 600 400 MM-64 2 3.1 MB-64 4 1.1 MF-64 2 3.1 565 350 MR-64 555 351 600 600 MM-66 2 5.5 MB-66 4 1.7 MF-66 2 5.5 565 550 MR-66 555 551 700 500 MM-75 2 4.6 MB-75 4 1.7 MF-75 2 4.3 665 450 MR-75 645 451 800 600 MM-86 2.5 9.9 MB-86 4 2.3 MF-86 2.5 9 765 550 MR-86 750 551 800 800 MM-88 2.5 13.6 MB-88 5 4.5 MF-88 2.5 12 765 750 MR-88 750 751 1000 800 MM-108 2.5 16.9 MB-108 5 5.7 MF-108 2.5 16 965 750 MR-108 945 751 1000 1000 MM-1010 2.5 18.6 MB-1010 5 7.1 MF-1010 2.5 17 950 950 MR-1010 945 951 1200 800 MM-128 2.5 17.8 MB-128 5 6.8 MF-128 2.5 17 1150 750 MR-128 1145 751 1200 1000 MM-1210 2.5 21.7 MB-1210 5 8.3 MF-1210 2.5 20 1150 950 MR-1210 1145 951 2/22 02_017_023.indd 22 17/3/08 11:14:32 CRSX-CRXH Mounting accessories Adjustable plate supports for CRSX and CRXH enclosures Supports to be fitted into CRSX and CRXH enclosures with depths of 200, 300 and 400 mm. The rail has positioning notches along its entire length for depth adjustment of the plate and other accessories every 12.5 mm. To couple the enclosures with depths (mm) Reference SDCR 200 200 SDCR 250 250 SDCR 300 300 12.5 30 44 Screws and accessories for universal plates Fixing nut Thread type Fixing screw with washer Length (mm) Pack units M3 TFP 3 100 M4 TFP 4 100 M5 TFP 5 100 M6 TFP 6 100 Packaging - - - TOR 10/4 A 10 100 TOR 16/4 A 16 100 TOR 12/5 A 12 100 TOR 18/5 A 18 100 TOR 12/6 A 12 100 TOR 18/6 A 18 100 15 15 11 ⫻ 26 mm 30 30 GCR fasteners Clip in fasteners to be installed directly on 19” racks and on slotted MR mounting plates. Ref.: GCR. 2/23 02_017_023.indd 23 17/3/08 11:14:33 CRSX-CRXH Applications Dinimel DLM distribution chassis Distribution chassis set for modular equipment, ref.: DLM-… with a distance between the 35 mm symmetric profile and the cover, which is adjustable as needed by the customer from 40 to 85 mm. c Rigid structure made of galvanised steel. c Metal cover and frame, colour RAL-7032. Quick mounting, without the need for screws. c System for identifying circuits included in the standard supply. c Earth and neutral bypass terminal block ref.: RBLZ/21656 (included in standard supply). DLM-48 (600) (500) (400) DLM-24 (600) (600) (400) (300) (700) (500) (400) DLM-48P DLM-84P DLM-66 (800) DLM-88 DLM-84 DLM-112 DLM-240 C>150 E C=150 * For glazed door consider 4 mm less. Note: For 150 mm enclosures, the DLM chassis may be fixed at the back of the enclosure or at the front. For deeper enclosures, the mounting plate can be installed at the back. In this case, the depth of the chassis may be adjusted using the SDCR adjustable supports (on request). 85 46 85 E (800) (700) (500) (1000) (800) (600) (600) 26 36* 10 C-124 36* 150 C-140 40 40 71 C-79 D Distribution of rows For use with CRSX and CRXH enclosures Automatic rail Reference Plain door Transparent door No. of rows Quantity No. of 18 mm modules No. of plain covers D E …-43 …-43/KT DLM-24 2 2 24 - 216 103 …-54 …-54/KT DLM-48 3 3 48 - 288 78 …-64 …-64/KT DLM-48P 3 3 48 - 288 128 …-66 …-66/KT DLM-84P 3 3 84 - 504 128 …-75 …-75/KT DLM-66 4 3 66 1 395 103 …-75 …-75/KT DLM-88 4 4 88 - 395 103 …-86 …-86/KT DLM-84 4 3 84 1 504 153 …-86 …-86/KT DLM-112 4 4 112 - 504 153 …-108 …-108/KT DLM-240 6 6 234 - 704 103 Plain covers Mounting plates CTL300DLM PMP300DLM CTL400DLM PMP400DLM CTL600DLM PMP600DLM CTL500DLM PMP500DLM CTL600DLM PMP600DLM CTL800DLM PMP800DLM Blanking plates ATP/72G (72 mm) 4 modules ATP/UND (1100 mm) 2/24 02_024_025.indd 24 17/3/08 11:15:32 CRSX-CRXH Applications Terminal blocks Earth and neutral terminal blocks with insulated plinth. Direct fixed by pressure on the distribution chassis, by pressure. Number of terminals ⫻ section in mm2 Reference RBLZ/21656* 2⫻16 mm2 + 5⫻6 mm2 RBLZ/21686 2⫻16 mm2 + 8⫻6 mm2 RBLZ/216146 2⫻16 mm2 + 14⫻6 mm2 RBLZ/216296 2⫻16 mm2 + 29⫻6 mm2 * Included in standard supply. Blanking plate Blanking plate of self-extinguishing insulated material for total or partial coverage of the windows for automatics. Easily cut to the desired size. Reference Length (mm) No. of modules ATP6/DTM 108 6 ATP24/DTM 432 24 1100 Cut to size ATP/UND 2/25 02_024_025.indd 25 17/3/08 11:15:41
Similar documents
Wall-mounting steel enclosures suitable for any CRN and CRNG
c Adjustable support plate. c Built-in cable entry plate, flush with the back of the enclosure (without foamed-in gasket to facilitate machining). c Three-point locking system for one and two doors...
More information