UltraBeam X-Powerpack
Transcription
UltraBeam X-Powerpack
UltraBeam X-Powerpack Xenon Gas Discharge Work Lamps Mounting Instructions Please retain for future reference Upright (Pedestal) Mount HMUBXSWBD-12V HMUBXSWBD-24V Pendant Mount HMUBXHWBD-12V HMUBXHWBD-24V Integral Xenon Ballast (non replaceable) D1S Xenon Globe HMXN4001 Wide Beam Optic (not serviceable) DT Plug Pin Configuration (front view) Clear Protective Cover HM8160 112 136 101 84 Torque settings for bolts 20Nm 143 24 87 911-354-69 73 www.hella.com.au Customer Service: Free Call 1800 061 729 custservice@ha.hella.com UltraBeam X-Powerpack Xenon Gas Discharge Work Lamps Mounting Instructions Please retain for future reference Technical Data Ballast to combine with Xenon HID globe D1S/35W Specifications 12V DC 24V DC Nominal Voltage 13.5V 27V Lower switch-on 7.5V 15V Operating voltage range Below this voltage the operating time is limited 10V to 16V 20V to 32V < 9V for 10 min at TG < 85°C < 12V for 10 min at TG < 85°C c. 35W c. 35W Power consumption Peak current @ rated voltage (100m/s max.) Activation current (10s max.) Nominal current @ rated voltage Pre-connected fuse 16A 7.5A < 17A < 8.5A 3.1A 1.5A 15A (16A) 7.5A Power output 35W ± 1W at TG 25°C Non-load ignition voltage on lamp cable 1.1kV (max. 1.35kV) Lamp voltage range 67V to 112V Operating temperature range -40°C to +80°C Mass 1.26kg Lamp Type D1S Protection (with suitable plug) IP6K9K Shock & vibration rating Ballast 200G; Housing 200G; Lamp 30G Electromagnetic compatibility WHEN OPERATING THE LAMP, PLEASE OBSERVE THE FOLLOWING: • Do not operate in small, closed spaces • Distance between lens and combustible material must be at least 0.5 metre • Do not look directly into the bright light WARNING! Do not clean with liquid when the lamp is switched on and the lens is hot as the lens may break. CONNECTION OF BALLAST TO POWER SUPPLY • The ballast generates high voltage. Do not touch the connection lead to the xenon globe or other parts of the ballast when turning the power on. • Always use the ballast in combination with the D1S xenon gas discharge globe. • Adhere to maximum temperature requirements of the ballast. • All power supply and charging systems must adhere to the voltage limits specified. • Use cables of 5mm² or larger are required for each lamp to assure proper starting characteristics. The electrical connection between the ballast and the battery must not have an interior resistance exceeding 150 mOhms (12V) or 300mOhms (24V). • Do not start more than three ballasts at once. Another three additional ballasts can be started after 20 seconds. • The ballast is equipped with a ‘reverse polarity protection’ and will operate at correct connection only. 911-354-69 EMC Class 5 according to CISPR25 EXCHANGE OF D1S GLOBE • Always switch off the work lamp ballast before exchanging the D1S globe and disconnect from the power supply. • Allow the xenon globe to cool off. • Never touch the glass of the xenon globe, touch the xenon globe at its base only. If required, use a clean cloth and alcohol to remove fingerprints from the glass carefully. • The glass body of the xenon globe is filled with various gasses and metal vapours under pressure (danger of splintering). Always wear safety goggles and gloves when exchanging xenon globes. • Dispose of used xenon globes as hazardous waste. • Always use the ballast in combination with the D1S globe, which is placed inside the closed work lamp. • Connect the D1S globe securely in the connector. Incomplete connection of the D1S globe can result in damage to the product or other equipment, or electric shock. • The ballast operation is stopped within 1 second of the D1S globe disconnecting. NOTE Hella shall be absolved from all responsibility for any modifications performed on the luminaire. Use only certified original equipment for replacement purposes. © Hella Australia 2009