P30U

Transcription

P30U
P30U TRANSDUCER OF TEMPER ATURE AND STANDARD SIGNALS

NOTICE!
N E W
functions!
FEATURES:
• Universal measuring input.
Version: standard, with SD card, with Ethernet and internal memory.
Mathematical functions, i.a. median filter function on measured value.
Individual characteristic (up to 21 points).
• 1 or 2 (option) alarm output.
• Built-in power supply of object transducers 24V d.c. (option).
• RS-485 interface Modbus RTU Slave, RTU Master or Monitor.
• Modbus TCP Slave (option).
• Possibility
to
record
one
measuring
value
and simultaneously up to 50 read-out/ written values
via RS-485 Modbus Master.
• Data recording in internal memory, up to 4MB or in external SD/SDHC
card or internal file system memory (8 GB) (option).
• Transducer programmable using buttons, eCon freeware
(through RS-485 or Ethernet) or any web browser (through Ethernet).
• Firmware upgradeable by the user.
•
••


eCon


Program
EXAMPLE OF APPLICATION:
21 points
charact.
Alarm
RTC
Password
protection
RS-485
Modbus
P30U
transducer
Wireless
transmission - SM7 Operator panel
Ethernet
4-20 mA
Internet/WWW
TCP IP
4-20 mA
INPUT:
Object sensor
(pressure, flow, etc.)

DC
RS
485
OUTPUT:
+
-
U
RS
485
GALVANIC
ISOLATION:
Coefficiant
k*
-10...10 V
-24...24 V
-20...20 mA
4
5
10
Resistance 400
0...400 
4
Resistance 2000
0...2000 
2
0...5500 
-200...850 oC
-200...600 oC
-200...850 oC
-200...180 oC
2
-200...850 oC
3
Ni100
Ni1000
-200...250 C
-200...850 oC
-60...180 oC
-60...150 oC
4
2
1
2
Ni100-LG
-60...180 oC
1
Ni1000-LG
-60...180 oC
2
Input type
Voltage 10 V
Voltage 24 V
Current
Resistance 5500
Pt100
Pt250
Pt1000
Zasilanie
Ethernet
Export department:
+48 68 45 75 139/ 233/ 276/
305/386
Fax: +48 68 32 54 091
e-mail: export@lumel.com.pl
„LUMEL” S.A.
ul. Słubicka 1
65-127 Zielona Góra
POLAND
WWW.LUMEL.COM.PL
Measurement
and
signal
conversion
with its visualization and retransmission.
I����
Nominal
measuring range
Z
Pt500
RS
485
NA5 meter
with bargraph
Temperature Shunt
sensor
Cu100
o
o
5
4
3
3
-50...180 C
1
-5...20 mV
1
-75...75 mV
4
-200...200 mV
4
Range
Minimal
sub-range with
class preservation
0...400 oC
-200...1200 oC
0...400 oC
1
2
1
-200...1370 oC
2
0...1760 oC
2
-20...420 oC
1
Thermocouple R type
-200...1300 oC
-40...260 oC
-200...1000 oC
0...1760 oC
1
1
2
2
Thermocouple T type
-200...400 oC
1
Thermocouple B type
400...1800 oC
1
Input type
Thermocouple J type
Thermocouple K type
Thermocouple S type
Thermocouple N type
Thermocouple E type
In
the
Master
mode of RS-485 interface,
can poll up to 50 registers
device,
with
implemented
Modbus protocol, using RS-485 interface.
In this mode, it is not possible to poll the transducer
by another Master device.
the transducer
 from
one
RS-485
Voltage mV

In the Master mode of RS-485 interface,
the transducer can monitor activity of the RS-485
connection and react (accept as a measured value)
to the value of the frame of the selected slave
device.
The
transducer
can
analyze
up to 50 registers from one device. In this mode,
it is not possible to poll the transducer by another
Master device.
Accuracy class = 0.1 with the exception of N, E and T thermocouples, where accuracy class = 0.2 and S, R, and B thermocouples,
where accuracy class = 0.5.
k* coefficiant of narrowing the measuring range with keeping the accuracy class.
NOTE: Minimal sub-range with keeping the accuracy class is z/k (it is freely programmable).
Example: 10 Z = -10...10V;
k = 10
Z/k = 2 V, so the minimal sub-range can be e.g. -1...1 V; 0...2 V; 5...7 V
P30U
Output type
Analog
Relay
O�����
Properties
Current: 0/4...20 mA, load resistance ≤ 500 Ω
Voltage: 0...10 V, load resistance ≥ 500 Ω
Remarks
accuracy class: 0.1
1 or 2 relays; voltageless contacts – NO – maximum load 5A 30V d.c., 250V a.c.
SEE ALSO:
Supplying output 24 V d.c. / 30 mA (option)
Interface type
RS-485
D������ ���������
Protocol
Modbus RTU: 8N2, 8E1, 8O1, 8N1; Address 1…247
Baud rate
4.8, 9.6, 19.2, 38.4, 57.6, 115.2, 230.4, 256 kbit/s
E������� ��������
Overall dimensions
45 x 120 x 100 mm
Weight
 0.25 kg
for housing: IP40/ IP30
LCD 2 x 8
Protection grade
Readout field
Temperature
sensors
for terminals: IP20
R���� ��������� ����������
• 85..253 V d.c. / a.c. (40..400 Hz)
Supply voltage
• 20..40 V a.c. (40..400 Hz) or 20…60 V d.c.
Temperature
Relative humidity
Working position
ambient: -25...23...+55°C
25...95 %
any
Power consumption  6 VA
storage: -30...+70°C
inadmissible condensation
S����� ��� ������������� ������������
Electromagnetic compatibility
Isolation between circuits
Pollution level
Installation category
Maximal phase-to-earth voltage
Altitude above see level
N30U meter
acc. EN 61000-6-2
acc. EN 61000-6-4
acc. EN 61010-1
noise immunity
noise emissions
basic
2
III
• for supply circuits 300 V
• for other circuits 50 V
< 2000 m
acc. EN 61010-1
C��������� �������
LUMEL - PROCESS
software
OUR OFFER
ORDERING
P30U -
X
XX X
Analog output:
current (range 0/4...20 mA)
1
voltage (0...10 V)
2
Additional equipment:
without any
0
with external SD/SDHC slot
1
with Ethernet interface and internal file
2
system memory
Addition output:
NO relay, 5 A 30 V d.c., 250 V a.c.
supply 24 V d.c. / 30 mA
Supply:
85...253 V a.c./d.c.
20...40 V a.c., 20...60 d.c.
Version:
standard
custom-made*
Language version:
Polish
English
other*
Acceptance tests:
without extra requirements
with an extra quality inspection certificate
according to customer’s request*
X XX X
X
www.lumel.com.pl
ACCESORIES:
Capacity
1 GB
2 GB
1
2
1
2
SD CARD
Ordering code
20-199-00-00023
20-199-00-00025
Order example:
00
XX
Code P30U-111100P0 means transducer execution
with current output, slot for SD/SDHC card, with 2 alarm
relays, 85..253 V a.c. / d.c. (40...400 Hz) power supply,
standard version, Polish language, without extra requirements.
P
E
X
0
1
X
* after agreeing with the manufacturer.
For more information
about LUMEL
products please visit
our website:
www.lumel.com.pl
Export department:
+48 68 45 75 139/ 233/ 276/
305/386
Fax: +48 68 32 54 091
e-mail: export@lumel.com.pl
„LUMEL” S.A.
ul. Słubicka 1
65-127 Zielona Góra
POLAND