INVERTER HYDRAULIC UNIT
Transcription
INVERTER HYDRAULIC UNIT
INDEX INVERTER HYDRAULIC UNIT List of Hybrid Hydraulic Unit Models P.3 to 4 List of Super Unit Models Nomenclature P.5 Main Features and Functions Super Unit Hydraulic Circuits P.6 Features P.7 to 8 Functions P.9 Function Option P.10 Hardware Option P.11 Pressure – Flow Rate Characteristics (Representative) P.13 to 14 Specifications/External Drawings 7 MPa P.15 to 24 Specifications/External Drawings 10 MPa P.25 to 28 Specifications/External Drawings P.29 to 32 Specifications/External Drawings 21 MPa P.33 to 38 Part Names, Functions, and the Operation of the Operation Panel P.39 to 40 Power Supply and I/O Signal Cables P.41 to 42 Harness Specifications (Recommended Parts) P.43 Option P.44 Method of Selection P.45 Handling P.46 16 MPa Oil Hydraulic Division Oil Hydraulic Equipment O Get more than energy savings!! Saving energy is essential. However, the Daikin hydraulic system goes one step further than conventional models. Daikin practices environmentally friendly production by promoting energy savings in the production field and by reducing waste through recycling. In the pursuit of higher usability and more diversified functions, Daikin combined its original high-efficiency IPM motors and pump switching control technology. The Super Unit incorporates the multi-stage pressure/flow rate control system as well as the functions of conventional hydraulic units, resulting in the use of fewer valves. Daikin intends to promote energy savings through advanced hydraulic systems with the aim of contributing to improvement of factory environments, and to continuously introduce hydraulic systems that lead the industry. 01 Combining Daikin’s original high-efficiency IPM motors and hydraulic technology enables an unparalleled energy-saving effect and advanced functions. Energy-saving technology that supports hybrid products ♦ Daikin was the first in the industry to introduce an interior permanent magnet synchronous motor (IPM motor) into air conditioners for household use. Daikin was also an early adopter in the industry of the IPM motor for use in industrial-use air conditioners. We have led the industry as a front runner in air conditioner energy-saving performance. ♦ Hybrid products equipped with variable speed motors, developed by making full use of Daikin’s original energy-saving motor technology and its production capacity, help to achieve Powerful energy savings for factory equipment “Double torque” improves the energy-saving effect. Combining two rotational forces, “magnetic torque” generated by a powerful neodymium magnet1 and “reluctance torque”2, generates more power with less electricity. Neodymium magnet Ferrite magnet Neodymium magnets provide more power – substantially more than the ferrite magnets in general use. neodymium magnets, the key to this improved energy-saving effect! 1: A compound of neodymium (Nd, rare-earth element), iron (Fe), and boron (B). Neodymium magnets are known to have superior magnetic properties. 2: Rotational force generated by attractive force (reluctance = magnetic resistance) between iron and a magnet. Fundamental Principle of the IPM Motor With a rare-earth permanent magnet deeply embedded in the rotor, the IPM motor uses an electromagnetic structure that maximizes magnetic torque (attractive/repulsive force between the coil and permanent magnet) and reluctance torque (force of the coil that attracts iron). This structure achieves high torque and maximum efficiency while suppressing heat generation. Structure of the IPM motor Stator Structure of a conventional motor (AC servomotor) Iron Stator Rare-earth magnet IPM motor drive system (Interior permanent magnet synchronous motor) S N N S Rotor N [1] Comparison of motor efficiency 0 1 2 3 The lengths of the magnetic field lines at the south and north poles are equivalent. Therefore, no reluctance torque that results in rotational force is generated. Daikin IPM motor 4 Rated output (kW) 5 120 • Daikin IPM motors are capable of outputting a large torque in low-speed ranges, eliminating the problems with insufficient torque in low-speed ranges often observed with general-purpose inverters. 100 80 General-purpose induction motor 60 40 General-purpose induction motor 70 N (Surface permanent magnet synchronous motor: e.g., servomotor, brushless DC motor) N Torque (%) Motor efficiency (%) • Daikin IPM motors have even greater efficiency than general-purpose induction motors and high-efficiency induction motors. High-efficiency induction motor 75 S 140 90 80 S [2] Large torque at low speed 95 85 SPM motor N S Daikin IPM motor 100 65 Rotor Since the magnetic field lines at the south pole side are made longer than those at the north pole side, the magnetic field lines at the south pole will try to shorten like a stretched rubber band contracts, resulting in rotational force due to reluctance torque in the direction indicated by arrow. S Magnet Rotating magnetic field 20 6 0 0 1000 2000 3000 4000 Rotation speed (min−1) 02 Specifications vary depending on the machine The Daikin product lineup provides various Maximum discharge rate For machine tools EcoRich EcoRich R Super EcoRich 110 L/min SUT00S11007 Equivalent to 11.0 kW See Pages 23 to 24 80 L/min SUT00S8007 SUT10S8007 Equivalent to 7.0 kW See Pages 21 to 22 60 L/min SUT00S6007 SUT06S6007 Equivalent to 5.0 kW See Pages 19 to 20 40 L/min SUT00S4007 SUT03S4007 Equivalent to 3.7 kW See Pages 17 to 18 30 L/min SUT00S3007 28.5 L/min EHU30-M07 EHU30RM07 Equivalent to 2.8 kW 25 L/min EHU25-L04 EHU25-L07 Equivalent to 2.2 kW Equivalent to 1.5 kW EHU25-M07 Equivalent to 2.8 kW EHU14-L04 EHU15RM07 Equivalent to 0.75 kW SUT03S3007 Equivalent to Equivalent to 1.5 kW Equivalent to 2.8 kW 15 L/min EHU30SM075R 2.8 kW See Pages 15 to 16 SUT00S1507 SUT03S1507 Equivalent to 2.2 kW Equivalent to 2.2 kW See Pages 15 to 16 Maximum operating pressure 4 MPa 16-pattern PQ control 03 6 MPa 7 MPa Idling stop 7 MPa Communication function 7 MPa Analog command input 7 MPa type. functions and capacities according to the machine type. Maximum discharge rate For general industrial machines Tankless type Super Unit Unit type 200 L/min SUT00D11021 List of Hybrid Hydraulic Unit Models Super Unit For molding machines SUT00S20018 P-SUT20D11KW Equivalent to 22.0 kW Equivalent to 11.0 kW 150 L/min See Pages 37 to 38 SUT00S15018 SUT00D8021 SUT10D8021 SUT16D8021 Equivalent to 15.0 kW 130 L/min Equivalent to 7.0 kW SUT00S13021 See Pages 35 to 36 SUT00D6021 SUT06D6021 SUT10D6021 80 L/min Equivalent to 15.0 kW SUT00S8018 Equivalent uivalent to 5.0 kW See Pages 33 to 34 SUT00D4016 50 L/min Equivalent to 11.0 kW SUT00S5021 SUT06D4016 Equivalent uivalent to 3.7 kW See Pages 31 to 32 SUT00S3010 30 L/min SUT00S3016 SUT03S3010 Equivalent to 3.7 kW Equivalent to 7.0 kW See Pages 29 to 30 SUT00S1510 Equivalent to 11.0 kW SUT06S3016 Equivalent to 5.0 kW See Pages 27 to 28 SUT00S3018 SUT00S1516 SUT03S1510 Equivalent to 2.8 kW SUT03S1516 Equivalent to 3.7 kW See Pages 25 to 26 10 MPa See Pages 29 to 30 16 MPa 21 MPa Maximum operating pressure 18 MPa 21 MPa *1: The above motor capacities are given for guidance only and do not represent the standard capacities of general motors. *2: When selecting a Super Unit, verify the specifications of each model by referring to “Pressure – Flow rate Characteristics (Typical)” on Pages 13 and 14 and “How to Select a Super Unit” on Page 45. For the purpose of making improvements, the specifications given in this catalog are subject to change without prior notice. Be sure to see the latest model chart. 04 List of Super Unit models Selecting the optimum model from a wide variety of Super Unit models Single pump type Super Unit Double pump type Maximum operating pressure (MPa) Motor capacity Series 10 20 30 Maximum flow rate (L/min) 40 50 60 70 80 Tankless type 90 Unit type Tank capacity (L) 100 110 Page Equivalent to 2.2 kW 7.0 SUT00S1507-30 SUT03S1507-30 30 Equivalent to 2.8 kW 7.0 SUT00S3007-30 SUT03S3007-30 30 Equivalent to 2.8 kW 10.0 SUT00S1510-30 SUT03S1510-30 30 25 to 26 Equivalent to 3.7 kW 7.0 SUT00S4007-30 SUT03S4007-30 30 17 to 18 Equivalent to 3.7 kW 10.0 SUT00S3010-30 SUT03S3010-30 30 27 to 28 Equivalent to 3.7 kW 16.0 SUT00S1516-30 SUT03S1516-30 30 Equivalent to 5.0 kW 16.0 SUT00S3016-30 SUT06S3016-30 60 Equivalent to 5.0 kW 7.0 SUT00S6007-30 SUT06S6007-30 60 19 to 20 Equivalent to 7.0 kW 7.0 SUT00S8007-30 SUT10S8007-30 100 21 to 22 Equivalent to 11.0 kW 7.0 SUT00S11007-30 — — 23 to 24 Equivalent to 3.7 kW 15.7 SUT00D4016-30 SUT06D4016-30 60 31 to 32 SUT06D6021-30 60 SUT10D6021-30 100 SUT10D8021-30 100 SUT16D8021-30 160 Equivalent to 5.0 kW 20.6 SUT00D6021-30 Equivalent to 7.0 kW 20.6 SUT00D8021-30 Equivalent to 11.0 kW 20.6 SUT00D11021-30 P-SUT20D11KW-30 200 15 to 16 29 to 30 33 to 34 35 to 36 37 to 38 Nomenclature Equivalent to 2.2 to 7.0 kW SUT 03 S 15 07 30 a b c d e f g h i a Model No. d Pump discharge rate SUT : SUT series b Tank capacity 00: 03: 06: 10: 16: Tankless type 30 L 60 L 100 L 160 L c Pump type 15: 15 L/min 30: 25 L/min 40: 40 L/min 60: 60 L/min 80: 80 L/min 110: 110 L/min e Maximum operating pressure 07: 10: 16: 21: h Hardware Option f Design No. Incremented at model changes 30, .... 01 02 03 g Function Option 04 C: With communication function (RS232C) P : With analog input function 7.0 MPa 10.0 MPa 15.7, 16.0 MPa 20.6 MPa 05 06 07 08 09 10 11 ... D: Double pump type S : Single pump type i Non-standard No. Full cover (except for 30 L tank) Controller cover (except for 7 kW) DCL (except for 7 kW) Separate power supplies for power system and control system Water fill test compliant tank Water leak test compliant tank Level switch Temperature switch Thermometer Micro separator Combination of 1 to 10 above Equivalent to 11 kW SUT 00 a b a Model No. SUT: SUT series b Tank capacity 00: Tankless type c Pump type D: Double pump type S: Single pump type 05 S c 110 d d Pump discharge rate ● 110: 110 L/min e Maximum operating pressure 07: 7.0 MPa 21: 20.6 MPa 07 30 f g h e f Design No. ● Incremented at model changes 30, .... h Non-standard No. N: Without control system A: With control system g Function Option C: With communication function (RS232C) P: With analog input function N: Without control system A: With control system Main features and functions 3 Energy-saving Daikin’s original high-efficiency IPM motor drive system with inverter technologies provides a high energy-saving ratio of 50%. (Compared to Daikin’s conventional variable piston pump) 4 The motor rotation speed control controls the flow rate and pressure of the fixed displacement pump. The highly-efficient motor adopted in this unit achieves energy savings even in applications for general industrial machinery where actuators have high duty ratios. The single pump type is a highly-functional series to make it more useful. The double pump type uses the autonomously-switching, fixed-displacement double pump system, which combines large- and small-capacity pumps in the low pressure, high flow rate range, and autonomously switches to the single operation of the high-pressure, small capacity pump in the high pressure, low flow rate range. In this way, the double pump type ensures a higher energy-saving effect. 2 Excluded from high-efficiency motor regulations The Super Units that incorporate a dedicated inverter driven motor are excluded from high-efficiency motor regulations. Restricted oil temperature rise Motor speed control also leads to restriction of the oil temperature rise. The restricted oil temperature rise inhibits deterioration of the hydraulic oil. This also lowers the heat load for air conditioning equipment 5 Fewer control valves required A wide variety of control can be achieved by adjusting parameter settings. Low noise Acceleration/deceleration operations that have been accomplished using proportional control valves may be replaced by simply setting the acceleration/deceleration time. Pressure switch may be reduced by using the pressure switch function. Low noise level of 60 dB (A) (In the pressure retained operation at 20.6 MPa, with the double pump type unit) Even over the full operation range, noise is less than 73 dB (A). By using double phase-differential pumps, the Super Unit reduces pulsation and the noise level. (Note that some kinds of control are not applicable depending on the customer’s circuit. Care must be taken especially when controlling multiple axes.) * Data for SUTD60L21 Functions 1 3 Multi-stage pressure/flow rate control Sixteen pressure (P) - flow rate (Q) setting patterns are available for cylinder control. Communication function (Available as an option with all models) Remote control and setting changes are possible through RS232C serial communication. The proportional control valve and proportional pressure control valve, which are utilized in conventional actuator circuits, can be omitted. The pressure and flow rate can be set using the control unit’s operation panel. The pressure and flow rate settings can be selected from among the sixteen patterns using external input signals. The Super Unit autonomously switches between the pressure control and flow rate control modes. 2 Using a commercially-available PLC or touch panel display with RS232C communication capabilities, parameters for the pressure, flow rate, acceleration time, deceleration time and so on can be set and viewed at the machine. This facilitates control of speeds and pressurizing forces and enables a wide variety of machine operations. 4 Maintenance/Management Function (Hybrid-Win) Internal data of the Super Unit can be obtained by using PC connected to the unit. List of Super Unit Models, Nomenclature, Main Features and Functions Features 1 Analog command input (Available as an option with single pump type models) Enables continuous control of pressures and speeds as required. PC tool Supported The pressure and flow rate can be controlled continuously at the desired values by inputting the pressure command voltage (0 to 10 V) and flow rate command voltage (0 to 10 V) from the machine side. This achieves a control system with a simple configuration for machinery that requires variable speed control or continuity of pressurizing forces. The pressure, flow rate, and other internal data of the inverter can be monitored and displayed in the form of graphs. This facilitates operation checks during test runs, adjustment of parameters such as time constants, and troubleshooting. The time required for setting can be slashed by editing the parameter settings on the PC and writing them to the unit in a batch. The ability to read and save settings facilitates management. Super Unit hydraulic circuits (example for the unit type) Double pump type Single pump type P T Rc⅜ DR Rc1 Rp¾ Above oil level 6-1 C/R 7 6-2 M Hose Name Part No. 1 Tank 2 Suction strainer 3 Stop valve 4 Oil filler port-cum-air breather 5 Oil level gauge 6-1 Controller 6-2 Inverter driven motor pump 7 Oil cooler P Rc¾ 9 10 7 M T DR Rc1 Rc¾ Rp¾ 8 Above oil level 6-1 T M Hose P b B A C/R P1 (low pressure) P2 (high pressure) 6-2 M M Hose 3 Hose Hose Hose Name Part No. 1 Tank 2 Suction strainer 3 Stop valve 4 Oil filler port-cum-air breather 5 Oil level gauge 6-1 Controller 6-2 Inverter driven motor pump 7 Oil cooler 8 Return filter 9 Check valve with holes 10 AC fan Hose 3 Rc½ 1 2 4 5 1 2 4 5 Rc½ 06 Features With excellent ll t energy-saving technology, the Super Unit can substantially reduce electricity costs. The control system can be easily upgraded by combining various Super Unit functions. Feature 1 Energy-saving Excellent cost effectiveness with energy-saving ratio of 50% (In pressure retained operation at 20.6 MPa) Based on Daikin’s original air-conditioning motor and inverter technologies, the Super Unit incorporates the high-efficiency IPM motor drive system, which ensures both a high response speed and stable rotation speed control with fixed-displacement pumps. In pressure holding mode, the Super Unit autonomously reduces the motor rotation speed to the minimum value required to hold the pressure, thus ensuring energy savings of 50% or higher (compared with the conventional Daikin variable piston pump). The Super Unit can even provide an energy-saving effect with general industrial machinery in which actuators provide a high duty ratio, as well as in pressure holding mode. Existing hydraulic unit Super Unit 7 Power consumption (kW) Power consumption (kW) 7 6 5 4 3 2 1 0 6 5 4 3 2 1 0 Operation time Operation time Comparison of annual power consumption Power consumption (kW) 7 6 5 3 1 POINT 2 5.74 kWh 2 1.62 kWh Existing hydraulic unit Annual energy-saving effect Decreased by $494.4 (¥494,400) [Estimation conditions] Existing hydraulic unit: Model of Super Unit: Cost of electricity: Annual operation time: 1$: 4 0 Feature Power consumption (average during operation) Approx. 72% reduction Super Unit double gear pump SUT10D6021 ¥15/kWh 8000 hours ¥100 The solenoid operated relief valve used in the existing hydraulic unit is eliminated by pressure control with a Super Unit. This results in an approximately 72% reduction in power consumption. Low noise Low noise level of 60 dB (A) (In pressure retained operation at 20.6 MPa, with the double pump type unit) Even over the full operation range, noise is less than 73 dB (A). Running the motor at the minimum required rotation speed through inverter control achieves a remarkable noise level reduction in pressure holding mode. Examples of typical noise levels In a subway train In a bus or train Ordinary conversation Noisy office Quiet park Suburban areas at night Full operation range Low noise level Double pump type in pressure holding mode at 20.6 MPa Super unit 07 dB 90 80 70 60 50 40 It is generally known that ordinary conversation can be conducted with a person one meter away in an environment at a noise level of 60 dB (A). Feature 3 Excluded from high-efficiency motor regulations High-efficiency motor regulations will be enforced in Japan in April 2015. These regulations will apply to the hydraulic units equipped with general motors but the Super Units that incorporate a dedicated inverter driven motor will be excluded from them. Eliminates the need for replacement of motors for each destination Eliminates the need for design changes in accordance with amendments to the regulations Reduces design changes to spare parts, and the maintenance workload Advantages of using hybrid hydraulic units 4 Restricted oil temperature rise Restriction of the temperature rise of the hydraulic fluid is one of the effects achieved by adopting Super Units. This generates the following advantages. Improved machining accuracy Reduced thermal distortion improves the machining accuracy. Reduced air-conditioning heat load The reduced heat load on the air conditioner achieves further energy savings. Feature 5 Features Feature Extended service life of packing and other sealing materials Improved maintainability Deterioration of the packing and other sealing materials that are made of rubber, used for hydraulic valves and hydraulic cylinders, is restricted. Extended service life of the hydraulic fluid Reduced environmental load and improved maintainability Restricted deterioration of the hydraulic fluid extends its replacement interval. Fewer control valves required Example hydraulic press circuit configuration Reducing the Number of Control Valves by Creating a Software-based System Configuration Elimination of the throttle valve Throttle valve Standardization of the solenoid valve Special spool shockless solenoid valve General-purpose solenoid valve Elimination of the proportional control valve M Combination flow/single flow switching valve Control unit Driver M Proportional relief valve Conventional system configuration Super Unit system configuration 08 Functions Function 1 Multi-stage pressure/flow rate control (16 PQ control setting patterns) Featured with standard models The force (pressure) and speed (flow rate) of the actuator (cylinder) can be controlled with 16 pressure (P) and flow rate (Q) setting patterns. The proportional control valve and proportional pressure control valve, which are utilized in conventional actuator circuits, are not required. Once the pressure and flow rate have been set at the controller’s operation panel, you can select 16 preset patterns using external input signals. The Super Unit autonomously changes the control mode from flow rate control to pressure control (example: flow rate control is changed to pressure control at the cylinder stroke end). The solenoid valve that actuates the cylinder must be turned ON/OFF at the machine. Smooth changing of force (pressure) and speed (flow rate) Once acceleration time and deceleration time parameters are registered, the force or speed can be changed gradually during a pressure/flow rate setting change. Example of PQ control setting patterns PQ selection 0 PQ Pattern selection: 0 PQ selection 1 Pressure: MPa PQ selection 2 PQ Pattern selection: 1 Pressure: MPa PQ selection 3 PQ Pattern selection: 2 Pressure: MPa PQ Pattern selection: 3 Pressure: MPa Speed (mm/s) Pressurizing force (kN) 160 140 Pressurizing force 120 Deceleration Cylinder speed low speed 100 Pressure release* 80 60 Lowered at high speed 40 Pressurizing (3-stage pressuring) 20 Meter-in control is performed for pumps. Raised 0 0 1.0 2.0 3.0 PQ selection 0 4.0 5.0 PQ selection 1 6.0 7.0 PQ selection 2 8.0 9.0 PQ selection 3 10.0 11.0 12.0 13.0 PQ selection 0 14.0 15.0 16.0 17.0 18.0 Time (sec) PQ pattern selection *: When pressure release control is disabled, an additional pressure release circuit should be provided for the load side. Function 2 Maintenance/Management function (Hybrid-Win) PC tool Supported This PC utility reads data from Daikin hybrid systems (Super Unit, EcoRich, oil cooling unit, etc.) and manages it. Parameter setting and monitoring can be accomplished efficiently using the Windows application. M a i n Displaying graphs The pressure, flow rate, and other internal data of the inverter can features be monitored and displayed in the form of graphs. This facilitates operation checks during test runs, adjustment of parameters such as time constants, and troubleshooting Reading, writing, editing, and saving parameters The time required for setting can be slashed by editing the parameter settings on the PC and writing them to the unit in a batch. The ability to read and save settings facilitates management. *: Hybrid-Win is utility software to monitor the internal status of Daikin hybrid systems using a PC. The software and its instruction manual can be downloaded from the website “http://www.daikinpmc.com/” free of charge by completing the user registration process. *: The communication cable is separately available. *: Some models require a dedicated separate monitor harness. *: It is possible to connect to a smart phone or factory LAN by adding an optional WiFi module. This is useful to facilitate the user’s daily inspection/maintenance work and for remote monitoring. 09 Featured with standard models Reading and saving the alarm history This function enables quick identification of the parts that require maintenance and reduction of the downtime. The operating time display can serve as the guide for the timing to replace consumable parts or to conduct maintenance. Troubleshooting information including the diagnosis results of the cause of an alarm and action to take can be displayed. Communication cable PC (to be prepared by the customer) Super Unit Function Option Optional function 1 Communication function The Super Unit and main machine can be remotely controlled with the same panel. This function eliminates complicated individual operations and installation space limitations. Enabling remote operation to change the operation conditions setting of the Super Unit Various settings such as acceleration/deceleration time and pressure switch settings, as well as the pressure and flow rate, can be set remotely. This makes it possible to control the hydraulic pressure operating conditions in synchrony with the control of the machine. Managing the pressure and flow rate at the machine The capability to read the operating conditions of the Super Unit makes it possible to display information such as the current pressure and flow rate on the screen at the machine. *: The serial communication interface conforms to the RS232C standard. Prepare a control unit such as a PLC or touch panel display with the RS232C communication function at the machine side. *: For details on the communication procedure, refer to the communication/remove control function instruction manual. Functions Optional functions Application of Super Unit Remote Operation and Communication Functions Installation in an elevated position or at a distance (within 15 m) Setting and monitoring P (pressure), Q (flow rate), and other data from the machine control panel Optional function 2 Analog command input The capability to specify the pressure and flow rate with voltage ranging from 0 to 10 V enables continuous hydraulic control as required. Real-time variation in response to commands facilitates condition settings at the machine side. A hydraulic control system for machinery that requires variable speed control or continuity of pressurizing forces can be realized with a simple configuration. A joystick or trimmer can be connected for real-time control. 10 Hardware Option Hardware option 1 Unit cover Optionally available for units with motor capacities equivalent to 3.7 kW, 5 kW, and 7 kW The cover protects the controller unit and piping. Hardware option 2 Controller cover Optionally available for models with motor capacities equivalent to 2.2 kW, 2.8 kW, 3.7 kW, and 5 kW Example of unit cover installation Example of controller cover installation The metal cover protects the controller unit. Hardware option 3 Built-in DC reactor Optionally available for models with motor capacities equivalent to 2.2 kW, 2.8 kW, 3.7 kW, and 5 kW Appropriate when it is necessary to improve the power factor or reduce the harmonics of the power supply Optionally available for compact models with the capacity of 5 kW or smaller. Provided as standard for models with a capacity of 7 kW or greater. Hardware option 4 Separate power supplies for power system and control system Optionally available for units with motor capacities equivalent to 2.2 kW, 3.7 kW, 5 kW, and 7 kW When an error occurs, only the main power supply is shut down and control power supply continues to carry current, thereby enabling the alarm code and internal status on occurrence of an error to be checked on the operation panel or through serial communication. Hardware option 5 Water fill test compliant tank, water leak test compliant tank Optionally available with all unit type models The water fill test, one of the adaptation criteria for the Fire Service Act, and the water leak test, Daikin original standard, are carried out. The tanks that pass the tests have compliance nameplates affixed and are delivered with the certificate. (Water fill test compliant tanks are not equivalent to Fire Service Act compliant tanks.) Hardware option 6 Level switch, temperature switch, thermometer, micro separator Optionally available with all unit type models The accessories that can be fitted to the tank are provided as optional parts. The accessories can be purchased separately as optional parts. (See Page 44.) 11 Hardware Option Memo 12 Pressure – Flow rate characteristics (Representative) SUTS1507, SUTS3007, SUTS4007, SUTS6007, SUTS8007, SUTS11007 110 100 SUTS11007 SUT SUT S11007 S11007 90 Flow rate (L/min) 80 SUTS8007 SUT SUT S8007 S8007 70 60 SUT SUT S6007 S6007 SUTS6007 50 40 SUT SUT SUTS4007 S4007 S4007 30 SUTS3007 20 * Operating flow rate at the maximum pressure in continuous operation: SUTS1507 SUT SUT S1507 S1507 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pressure (MPa) SUTS1507: SUTS3007: SUTS4007: SUTS6007: SUTS8007: SUTS11007: 3 L/min maximum 5 L/min maximum 8 L/min maximum 14 L/min maximum 19 L/min maximum 16 L/min maximum SUTS1510, SUTS3010 90 Flow rate (L/min) 80 70 60 50 40 30 20 SUTS3010 SUTS3010 SUT S3010 SUTS1510 SUT SUT S1510 S1510 * Operating flow rate at the maximum pressure in continuous operation: 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pressure (MPa) SUTS1510: 3 L/min maximum SUTS3010: 5 L/min maximum SUTS3016, SUTS1516 90 Flow rate (L/min) 80 70 60 50 40 30 SUTS3016 SUT S3016 SUTS3016 20 SUTS1516 SUT SUT S1516 S1516 * Operating flow rate at the maximum pressure in continuous operation: 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pressure (MPa) 13 SUTS1516: 5 L/min maximum SUTS3016: 5 L/min maximum Pressure – Flow rate characteristics (Representative) SUTD6021 100 100 90 90 80 80 70 70 Flow rate (L/min) 110 Flow rate (L/min) 110 60 50 40 60 50 40 30 30 20 20 10 10 0 0 5 10 15 Pressure (MPa) 0 0 20 * Operating flow rate at the maximum pressure in continuous operation: 8 L/min maximum SUTD8021 100 90 90 80 80 70 70 Flow rate (L/min) 100 Flow rate (L/min) 20 SUTD11021 110 60 50 40 60 50 40 30 30 20 20 10 10 5 10 15 Pressure (MPa) * Operating flow rate at the maximum pressure in continuous operation: 6.5 L/min maximum 110 0 0 5 10 15 Pressure (MPa) 20 * Operating flow rate at the maximum pressure in continuous operation: 14 L/min maximum Pressure – Flow rate characteristics (Typical) SUTD4016 0 0 5 10 15 Pressure (MPa) 20 * Operating flow rate at the maximum pressure in continuous operation: 16 L/min maximum 14 Super Unit [Single pump type] Maximum operating pressure Maximum flow rate 7 MPa 15/30 L/min Pressure – Flow rate characteristics (Representative) 110 Model code SUTS11007 SUT SUT S11007 S11007 100 SUTS1507-30 SUTS3007-30 90 SUTS8007 SUT SUT S8007 S8007 80 Flow rate (L/min) 70 SUT SUT S6007 S6007 SUTS6007 60 50 40 SUTS4007 SUT SUT S4007 S4007 30 SUT SUT SUTS3007 S3007 S3007 20 SUT SUT S1507 S1507 SUTS1507 10 1 Tankless type 2 3 4 5 7 8 9 10 11 12 13 14 15 16 Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: Unit type SUTS1507: 3 L/min maximum SUTS3007: 5 L/min maximum Tankless type Specifications Model Maximum flow rate (theoretical value; L/min) *1 Pump unit Unit type SUT00S1507-30 SUT00S3007-30 SUT03S1507-30 SUT03S3007-30 15.2 28.5 15.2 28.5 2.5 to 15.2 3.5 to 28.5 Equivalent to 2.2 kW Equivalent to 2.8 kW Maximum operating pressure (MPa) Operating flow rate adjustment range (L/min) 7.0 2.5 to 15.2 3.5 to 28.5 Operating pressure adjustment range (MPa) 1.5 to 7.0 Motor capacity Motor capacity (equivalent kW) Power supply Motor pump/unit AC3 φ200V (50 Hz) 11.5 15.4 11.5 15.4 Rated current (A) AC3 φ200V (60 Hz) 11.3 15.1 11.3 15.1 AC3 φ220V (60 Hz) 10.6 13.8 10.6 13.8 15 20 15 20 Power source breaker setting (A) Equivalent to 2.2 kW External output signal 5 channels 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load) 37 39 59 Usable oil *2 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum Operating hydraulic oil temperature (in tank) 0 to 60°C (Recommended operating temperature range: 15 to 50°C) Operating ambient temperature 0 to 40°C Storage ambient temperature –20 to 60°C Operating ambient humidity 85% RH max. (no condensation) Installation site Indoors (Be sure to secure the unit with bolts.) Others Tank capacity (L) Standard coating color Note) *1: *2: *3: *4: Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel Digital output Mass (kg) Operating conditions Equivalent to 2.8 kW 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%) External input signal 15 6 • Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. • Make sure that the electrical wiring meets the requirements of European Standard EN60204-1. • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life. To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function. • Be sure to connect the ground terminal. − 30 Ivory white (Munsell code 5Y7.5/1) The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. The unit incorporates a safety valve. When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 45. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. External dimension diagram Tankless type 15 Pressure indication and operation panel P Rc⅜ (Fitted with a vinyl cap at shipment) Quantity Inverter driven motor pump 1 1-2 Controller 1 2 AC fan 1 3 Base 1 15 (162) Name 1-1 344 Part No. 314 (254) SUT00S1507-30 SUT00S3007-30 4-φ10 holes (for fixing bolts) (M8 bolts recommended) 15 (87) 490 15 520 φ21 hole (Signal cable port) 1-2 (109) 2 30 460 30 520 Suction port: G¾ (Fitted with a vinyl cap at shipment) 3 DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) Optional port: Rp½ 135 545 SUT03S1507-30 SUT03S3007-30 (175) 170 50: 150 42 4-M8 (Manifold bracket mount) T Rc1 (Fitted with a vinyl cap at shipment) Part No. Name Quantity 1 Oil tank 1 2 Suction strainer 1 3 Stop valve 1 4 Oil level gauge 1 5 Oil filter port-cum-air bleeder 1 6-1 Inverter driven motor pump 1 100 92 (75) 3 P Rc⅜ (Fitted with a vinyl cap at shipment) 140 Optional port: Rp⅜ Pressure indication and operation panel (40) 196 (620) 6-2 (40) 5 6-2 Controller 1 Foundation plate (Option) (E-SUTPLATE-2) 7 Oil cooler 1 4-φ15 holes (for fixing bolts) (M12 bolts recommended) 8 AC fan 1 15/ 30 L/min Cleaning port 30 L Upper limit (Yellow line) Suction air Oil sampling port/ Oil drain port: Rc½ 20 (310) 6-1 2 462 7 1 Cleaning port tightening caution nameplate 23 L Lower limit (Red line) (516) SUT03S15L07-30 Unit nameplate 419 Safety caution nameplate φ28 hole (Power cable port) Wing bolt for fastening during transportation (at 1 location on the back) (To be removed before operation) 530 700 30 30 85 25 20 10 85 2-M8 (through hole) Tapped holes for mounting the foundation plate (at 4 locations) (50) 70 95 Bolt Caution nameplate 70 40 7 MPa 4 φ21 hole (Signal cable port) 8 Specifications and external dimension diagram 30 344 Unit type 1-1 Unit nameplate Safety caution nameplate (220) 284 ******** Suction air 45 45 30 DR Rc⅜ (Fitted with a vinyl cap at shipment) (246) (466) (421) (83) (260) φ28 hole (Power cable port) 155 450 500 (550) (580) 16 Super Unit [Single pump type] Maximum operating pressure 7 MPa 40 L/min Maximum flow rate Pressure – Flow rate characteristics (Representative) 110 Model code SUTS11007 SUT SUT S11007 S11007 100 SUTS4007-30 90 SUTS8007 SUT SUT S8007 S8007 Flow rate (L/min) 80 70 SUT SUT S6007 S6007 SUTS6007 60 50 40 SUTS4007 SUT SUT S4007 S4007 30 SUT SUT SUTS3007 S3007 S3007 20 SUT SUT S1507 S1507 SUTS1507 10 1 Tankless type 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: Unit type Specifications 8 L/min maximum Model Pump unit Tankless type Unit type SUT00S4007-30 SUT03S4007-30 Maximum flow rate (theoretical value; L/min) *1 39.7 Maximum operating pressure (MPa) 7.0 Operating flow rate adjustment range (L/min) 5.3 to 39.7 Operating pressure adjustment range (MPa) 1.5 to 7.0 Motor capacity Motor capacity (equivalent kW) Equivalent to 3.7 kW Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%) AC3 φ200V (50 Hz) 16.1 Rated current (A) AC3 φ200V (60 Hz) 15.8 AC3 φ220V (60 Hz) 14.8 20 Power source breaker setting (A) External input signal External output signal Operating conditions Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load) 46 64 Usable oil *2 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum Operating hydraulic oil temperature (in tank) 0 to 60°C (Recommended operating temperature range: 15 to 50°C) Operating ambient temperature 0 to 40°C Storage ambient temperature –20 to 60°C Operating ambient humidity 85% RH max. (no condensation) Installation site Indoors (Be sure to secure the unit with bolts.) Others Tank capacity (L) Standard coating color Note) *1: *2: *3: *4: 5 channels Digital output Mass (kg) 17 2 • Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. • Make sure that the electrical wiring meets the requirements of European Standard EN60204-1. • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life. To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function. • Be sure to connect the ground terminal. − 30 Ivory white (Munsell code 5Y7.5/1) The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. The unit incorporates a safety valve. When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 45. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. External dimension diagram P Rc½ (Fitted with a vinyl cap at shipment) Pressure indication and operation panel 15 Tankless type 1 1-2 Controller 1 2 AC fan 1 3 Base 1 15 (202) Quantity Inverter driven motor pump 354 Name 1-1 (294) Part No. 384 SUT00S4007-30 (87) 15 15 φ21 hole (Signal cable port) 1-2 1-1 Safety caution nameplate (108) 2 45 45 324 ******** Unit nameplate 30 3 30 460 30 Suction port: G¾ (Fitted with a vinyl cap at shipment) 520 384 Unit type DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) 545 T Rc1 (Fitted with a vinyl cap at shipment) 135 (175) SUT03S4007-30 170 4-M8 (Manifold bracket mount) Part No. Name Quantity 1 Oil tank 1 2 Suction strainer 1 3 Stop valve 1 4 Oil level gauge 1 5 Oil filler port-cum-air breather 1 6-1 Inverter driven motor pump 1 6-2 Controller 1 7 Oil cooler 1 8 AC fan 1 100 50: 150 42 92 (75) 3 Optional port: Rp½ Optional port: Rp⅜ 140 P Rc½ (Fitted with a vinyl cap at shipment) Pressure indication and operation panel (620) (40) Foundation plate (Option) (E-SUTPLATE-2) 196 4-φ15 holes (for fixing bolts) (M12 bolts recommended) (40) Specifications and external dimension diagram 220 Suction air DR Rc⅜ (Fitted with a vinyl cap at shipment) (245) (466) (421) (83) 30 4-φ10 holes (for fixing bolts) (M8 bolts recommended) (259) φ28 hole (Power cable port) 490 520 7 MPa 40 L/min 6-2 Cleaning port 23 L Lower limit (Red line) Suction air 6-1 8 20 Cleaning port tightening caution nameplate 2 462 EHU40R-M0703-30 Unit nameplate 7 1 30 L Upper limit (Yellow line) Oil sampling port/ Oil drain port: Rc½ (309) Safety caution nameplate φ28 hole (Power cable port) 4 (516) 5 419 φ21 hole (Signal cable port) 20 85 10 Wing bolt for fastening during transportation (at 1 location on the back) (To be removed before operation) (50) 70 95 2-M8 (through hole) Tapped holes for mounting the foundation plate (at 4 locations) 30 30 530 85 700 25 40 70 Bolt Caution nameplate 155 450 500 (550) (580) 18 Super Unit [Single pump type] Maximum operating pressure 7 MPa 60 L/min Maximum flow rate Pressure – Flow rate characteristics (Representative) 110 Model code SUTS11007 SUT SUT S11007 S11007 100 SUT00S6007-30 SUT06S6007-30 90 SUTS8007 SUT SUT S8007 S8007 Flow rate (L/min) 80 70 SUTS6007 SUT SUT S6007 S6007 60 50: 40 SUTS4007 SUT SUT S4007 S4007 30 SUT SUT SUTS3007 S3007 S3007 20 SUTS1507 SUT SUT S1507 S1507 10 1 Tankless type 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: Unit type 14 L/min maximum Specifications Model Pump unit Tankless type Unit type SUT00S6007-30 SUT06S6007-30 Maximum flow rate (theoretical value; L/min) *1 61.1 Maximum operating pressure (MPa) 7.0 Operating flow rate adjustment range (L/min) 8.7 to 61.1 Operating pressure adjustment range (MPa) 1.5 to 7.0 Motor capacity Motor capacity (equivalent kW) Equivalent to 5.0 kW Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%) AC3 φ200V (50 Hz) 22.1 Rated current (A) AC3 φ200V (60 Hz) 21.7 AC3 φ220V (60 Hz) 20.2 Power source breaker setting (A) External input signal External output signal 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load) 97 Usable oil *2 Operating hydraulic oil temperature (in tank) 0 to 60°C (Recommended operating temperature range: 15 to 50°C) Operating ambient temperature 0 to 40°C Storage ambient temperature –20 to 60°C Operating ambient humidity 85% RH max. (no condensation) Installation site Indoors (Be sure to secure the unit with bolts.) Tank capacity (L) Standard coating color 19 56 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum Others Note) *1: *2: *3: *4: Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel Digital output Mass (kg) Operating conditions 30 5 channels • Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. • Make sure that the electrical wiring meets the requirements of European Standard EN60204-1. • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life. To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function. • Be sure to connect the ground terminal. − 60 Ivory white (Munsell code 5Y7.5/1) The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. The unit incorporates a safety valve. When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 45. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. External dimension diagram Tankless type Unloading port Rc½ (Fitted with a vinyl cap at shipment) Pressure indication and operation panel 15 (140) P Rc¾ (Fitted with a vinyl cap at shipment) Quantity Inverter driven motor pump 1 1-2 Controller 1 2 AC fan 1 3 Base 1 4 Check valve 1 φ28 hole (Power cable port) (95) 15 4-φ10 holes (for fixing bolts) (M8 bolts recommended) 15 (136) 15 578 608 φ21 hole (Signal cable port) (180) Name 1-1 384 Part No. 354 (294) (73) SUT00S6007-30 1-2 4 ******** Unit nameplate 2 324 30 30 384 Unit type (86) 3 (143) 548 608 Suction port: Rc1 (Fitted with a vinyl cap at shipment) 30 DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) (85) 100 (327) (188) 170 150 SUT06S6007-30 T Rc¾ (Plugged at shipment) Optional port: Rp⅜ 3 Optional port: Rp½ P Rc¾ (Fitted with a vinyl cap at shipment) 4-φ15 holes (for fixing bolts) (M12 bolts recommended) Foundation plate (Option) (E-SUTPLATE-2) Pressure indication and operation panel (40) (40) (620) 9 6-2 Part No. 1 2 3 4 5 6-1 6-2 7 8 9 10 SUT06S60L07-30 60 Cleaning port tightening caution nameplate 60 L Upper limit (Yellow line) 45 L Lower limit (Red line) 2 Cleaning port (441) Suction air 20 8 20 85 (707) 30 30 85 2-M8 (through hole) Tapped holes for mounting the foundation plate (at 4 locations) (50) 70 Wing bolt for fastening during transportation (at 1 location on the back) 10 (To be removed before operation) 530 25 70 95 Bolt Caution nameplate 40 648 595 Unit nameplate 6-1 7 MPa 1 Safety caution nameplate 7 Quantity 1 1 1 1 1 1 1 1 1 1 1 L/min 4 5 10 Name Oil tank Suction strainer Stop valve Oil level gauge Oil filler port-cum-air breather Inverter driven motor pump Controller Oil cooler AC fan Return filter Check valve 639 (311) 100 4-M8 (Manifold bracket mount) 110 42 37 50: T Rc1 (Fitted with a vinyl cap at shipment) Specifications and external dimension diagram 45 30 (282) 1-1 Safety caution nameplate (95) 245 Suction air (226) (466) (421) DR Rc⅜ (Fitted with a vinyl cap at shipment) 450 500 155 Oil sampling port/ Oil drain port: Rc½ 20 Super Unit [Single pump type] Maximum operating pressure 7 MPa 80 L/min Maximum flow rate Pressure – Flow rate characteristics (Representative) 110 Model code SUTS11007 SUT SUT S11007 S11007 100 SUTS8007-30 90 SUTS8007 SUT SUT S8007 S8007 Flow rate (L/min) 80 70 SUT SUT S6007 S6007 SUTS6007 60 50 40 SUTS4007 SUT SUT S4007 S4007 30 SUT SUT SUTS3007 S3007 S3007 20 SUT SUT S1507 S1507 SUTS1507 10 Tankless type 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: Unit type Specifications 19 L/min maximum Model Pump unit Tankless type Unit type SUT00S8007-30 SUT10S8007-30 Maximum flow rate (theoretical value; L/min) *1 83.0 Maximum operating pressure (MPa) 7.0 Operating flow rate adjustment range (L/min) 11.6 to 83.0 Operating pressure adjustment range (MPa) 1.5 to 7.0 Motor capacity Motor capacity (equivalent kW) Equivalent to 7.0 kW Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%) AC3 φ200V (50 Hz) 25.5 Rated current (A) AC3 φ200V (60 Hz) 24.8 AC3 φ220V (60 Hz) 22.7 50 Power source breaker setting (A) External input signal External output signal Operating conditions Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load) 72 131 Usable oil *2 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum Operating hydraulic oil temperature (in tank) 0 to 60°C (Recommended operating temperature range: 15 to 50°C) Operating ambient temperature 0 to 40°C Storage ambient temperature –20 to 60°C Operating ambient humidity 85% RH max. (no condensation) Installation site Indoors (Be sure to secure the unit with bolts.) Others Tank capacity (L) Standard coating color Note) *1: *2: *3: *4: 5 channels Digital output Mass (kg) 21 2 • Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. • Make sure that the electrical wiring meets the requirements of European Standard EN60204-1. • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life. To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function. • Be sure to connect the ground terminal. − 100 Ivory white (Munsell code 5Y7.5/1) The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. The unit incorporates a safety valve. When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 45. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. External dimension diagram Tankless type 15 Motor cable Pressure indication and operation panel (139) SUT00S8007-30 P Rc¾ (Fitted with a vinyl cap at shipment) Inverter driven motor pump 1 1-2 Controller 1 2 AC fan 1 3 Base 1 4 Check valve 1 (125) 4-φ10 holes (for fixing bolts) (M8 bolts recommended) 15 15 (135) 15 (60) (196) 1-1 Unloading port: Rc½ (Fitted with a vinyl cap at shipment) 294 Quantity 354 Name 384 Part No. 600 630 1-2 4 DR Rc⅜ (Fitted with a vinyl cap at shipment) (90) 2 Transportation nameplate 30 3 Suction port: Rc1 (Plugged (with O-ring) at shipment) (142) 30 301 (244) 258 324 (85.5) Safety caution nameplate 45 30 (408) Unit nameplate Suction air 30 570 Wing bolt for fastening during transportation (at 2 locations) (To be removed before operation) Unit type (85) DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) (327) (188) 100 150 170 SUT10S8007-30 (441) 172 150 100 50: 17 T Rc1-½ (Fitted with a vinyl cap at shipment) 4-M8 (Manifold bracket mount) T Rc1-¼ (Plugged at shipment) Pressure indication and operation panel 3 Optional port: Rp⅜ Optional port: Rp½ P Rc¾ (Fitted with a vinyl cap at shipment) 4-φ15 holes (for fixing bolts) (M12 bolts recommended) (40) (620) Foundation plate (Option) (E-SUTPLATE-2) 6-2 (40) Part No. 1 2 3 4 5 6-1 6-2 7 8 9 10 Name Oil tank Suction strainer Stop valve Oil level gauge Oil filler port-cum-air breather Inverter driven motor pump Controller Oil cooler AC fan Return filter Check valve Quantity 1 1 1 1 1 1 1 1 1 1 1 Cleaning port 9 Specifications and external dimension diagram 483 (441) 1-1 7 MPa 80 L/min 4 5 Unit nameplate Safety caution nameplate 8 1 (441) Suction air 20 2 20 85 10 530 700 (188) (895) Wing bolt for fastening during transportation (at 1 location on the back) (To be removed before operation) 30 30 85 25 2-M8 (through hole) Tapped holes for mounting the foundation plate (at 4 locations) 155 (50) 70 70 95 Bolt Caution nameplate 40 (216) Cleaning port tightening caution nameplate 6-1 595 671 7 100 L Upper limit (Yellow line) 76 L Lower limit (Red line) (647) SUT10D80L07-30 10 450 50: 80 580 630 Oil sampling port/ Oil drain port: Rc½ 22 Super Unit [Single pump type] Maximum operating pressure Maximum flow rate 7 MPa 110 L/min Pressure – Flow rate characteristics (Representative) 110 Model code 100 SUT00S11007-30 SUTS11007 SUT SUT S11007 S11007 90 Flow rate (L/min) 80 SUTS8007 SUT SUT S8007 S8007 70 60 SUT SUT S6007 S6007 SUTS6007 50 40 SUTS4007 SUT SUT S4007 S4007 30 SUT SUT SUTS3007 S3007 S3007 20 SUT SUT S1507 S1507 SUTS1507 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pressure (MPa) Tankless type * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: 16 L/min maximum Tankless type Specifications SUT00S11007-30 Model Pump unit Maximum flow rate (theoretical value; L/min) *1 110 Maximum operating pressure (MPa) 7.0 Operating flow rate adjustment range (L/min) 13.3 to 110 Operating pressure adjustment range (MPa) 1.5 to 7.0 Motor capacity Motor capacity (equivalent kW) Equivalent to 11.0 kW Power supply Motor pump 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%) AC3 φ200V (50 Hz) 38.3 Rated current (A) AC3 φ200V (60 Hz) 37.8 AC3 φ220V (60 Hz) 34.9 Power source breaker setting (A) External input signal External output signal 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load) 23 112 Usable oil *2 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum Operating hydraulic oil temperature (in tank) 0 to 60°C (Recommended operating temperature range: 15 to 50°C) Operating ambient temperature 0 to 40°C Storage ambient temperature –20 to 60°C Operating ambient humidity 85% RH max. (no condensation) Installation site Indoors (Be sure to secure the unit with bolts.) Others Note) *1: *2: *3: *4: Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel Digital output Mass (kg) Operating conditions 75 5 channels • Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. • Make sure that the electrical wiring meets the requirements of European Standard EN60204-1. • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life. To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function. • Be sure to connect the ground terminal. Tank capacity (L) − Standard coating color Ivory white (Munsell code 5Y7.5/1) The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. The unit incorporates a safety valve. When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 45. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. External dimension diagram Tankless type Suction port: Rc1-¼ 819 SUT00S11007-30 87 Encoder wiring connector SUT00S−−A− MFG No.: Note 1. 151 INSULATION CLASS: F : 88 kg MASS PF V Hz A MAX. FLOW : 80 L/min 3φ 200 50: 62 0.94 60 62 0.94 MAX.PRESSURE : 17.6 MPa 3φ 200 60 61 0.94 3φ 220 DAIKIN INDUSTRIES,LTD. MADE IN JAPAN Motor wiring port (φ28) AC fan, thermistor wiring port (φ21) Drain port Rc⅜ 323 168 117 204 496 42 118 19 Discharge port Rc1-¼ Unloading port Rc¾ ■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■ ■■■■■■■■■■■■ ■■■■■■■■■■■■ 24: 3 207 112 76.5 108 95.5 132.5 241 228 275 Control unit SUT00S11007-30 SUT00D11021-30 Controller (Installed separately) Cooling fan Cooling fan Controller installation hole 4-φ8 (M6 bolts recommended) 11.5 <Top> Cooling fan suction 180 34 User I/O terminal (M3) • Encoder • Motor thermistor • Pressure sensor • I/O signal 7 MPa FG FG GND +5V Z- Z+ 感電のおそれがあります。 A- A+ ・通電中及び電源遮断後5分以内は ターミナルカバーを開けないで下さい。 THMTHM+ AGND AO2 (QO)AGND AO1 (PO) 361 233 378.5 May cause electric shock. ・Disconnect all power before opening terminal cover of unit. Wait 5 minutes until DC Bus capacitors dischange. DI7 DI8 DI2 DGND TxD INSULATION CLASS: F V 3φ 200 3φ 200 3φ 220 Hz 50: 60 60 A PF Main power supply terminal block (M5) • Main power supply • DC reactor • Regenerative resistor • Motor output DI4 DI1 FG MFG No.: DAIKIN INDUSTRIES,LTD. MADE IN JAPAN DI6 DI5 DI3 Product nameplate MASS : kg MAX. FLOW : L/min MAX.PRESSURE : MPa DO2 110 L/min DAIKIN INDUSTRIES,LTD. AGND AIN2 (QI) AGND AIN1 (PI) AGND P_S A5V ALM_C ALM_B ALM_A DOCOM DO7 DO6 DO5 DO4 DO3 DO1 Operation panel DANGER WARNING B- B+ 327.5 Specifications and external dimension diagram 4-14.5 (Installation) 15 108 Suction air 95 170 129 228 261 IN C D □EC &ast;&ast; DAIKIN INDUSTRIES,LTD. MADE IN JAPAN DICOM RxD FG 95.5 Controller nameplate DAIKIN PMC*** MFG No.:: Electromagnetic valve terminal block (M4) ****-****** INPUT : 3PH 200V 3PH 200/220V MASS : kg 50Hz 60Hz A: Cooling fan exhaust 39 6 17 DAIKIN INDUSTRIES,LTD. MADE IN JAPAN 207 212 (5) • Electromagnetic valve power supply • AC fan power supply 25 180 (25) (5) 230 (5) 240 24 Super Unit [Single pump type] Maximum operating pressure Maximum flow rate 10 MPa 15 L/min Pressure – Flow rate characteristics (Representative) 90 Model code 80 SUTS1510-30 Flow rate (L/min) 70 60 50 40 30 SUTS3010 20 SUTS1510 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pressure (MPa) Tankless type Unit type * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: 3 L/min maximum Specifications Model Pump unit Tankless type Unit type SUT00S1510-30 SUT03S1510-30 Maximum flow rate (theoretical value; L/min) *1 15.2 Maximum operating pressure (MPa) 10.0 Operating flow rate adjustment range (L/min) 2.5 to 15.2 Operating pressure adjustment range (MPa) 1.5 to 10.0 Motor capacity Motor capacity (equivalent kW) Equivalent to 2.8 kW Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%) AC3 φ200V (50 Hz) 8.0 Rated current (A) AC3 φ200V (60 Hz) 7.8 AC3 φ220V (60 Hz) 7.5 15 Power source breaker setting (A) External input signal External output signal Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load) Mass (kg) Operating conditions 5 channels 39 59 Usable oil *2 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum Operating hydraulic oil temperature 0 to 60°C (Recommended operating temperature range: 15 to 50°C) Operating ambient temperature 0 to 40°C Storage ambient temperature –20 to 60°C Operating ambient humidity 85% RH max. (no condensation) Installation site Indoors (Be sure to secure the unit with bolts.) Others Tank capacity (L) Standard coating color • Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. • Make sure that the electrical wiring meets the requirements of European Standard EN60204-1. • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life. To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function. • Be sure to connect the ground terminal. − 30 Ivory white (Munsell code 5Y7.5/1) Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower. *3: The unit incorporates a safety valve. *4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 45. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. 25 External dimension diagram Tankless type P Rc⅜ (Fitted with a vinyl cap at shipment) Pressure indication and operation panel Name Quantity 1-1 Inverter driven motor pump 1 1-2 Controller 1 2 AC fan 1 3 Base 1 15 (162) 344 314 Part No. (254) 15 SUT00S1510-30 φ28 hole (Power cable port) (87) 15 φ21 hole (Signal cable port) 490 4-φ10 holes (for fixing bolts) (M8 bolts recommended) 15 520 1-2 DR Rc⅜ (Fitted with a vinyl cap at shipment) 284 30 30 30 Suction port: G¾ (Fitted with a vinyl cap at shipment) (175) SUT03S1510-30 170 42 50: 150 100 4-M8 (Manifold bracket mount) T Rc1 (Fitted with a vinyl cap at shipment) Part No. Name Quantity 1 Oil tank 1 2 Suction strainer 1 3 Stop valve 1 4 Oil level gauge 1 5 Oil filter port-cum-air bleeder 1 6-1 Inverter driven motor pump 1 6-2 Controller 1 7 Oil cooler 1 8 AC fan 1 3 Optional port: Rp⅜ 141 P Rc⅜ (Fitted with a vinyl cap at shipment) Pressure indication and operation panel (620) (40) Foundation plate (Option) (E-SUTPLATE-2) 196 4-φ15 holes (for fixing bolts) (M12 bolts recommended) (40) 5 6-2 Specifications and external dimension diagram 520 Optional port: Rp½ 545 (75) 92 3 460 DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) 135 10 MPa 4 Cleaning port φ21 hole (Signal cable port) 15 L/min 30 L Upper limit (Yellow line) Unit nameplate 7 Suction air 20 6-1 Cleaning port tightening caution nameplate 1 2 462 23 L Lower limit (Red line) SUT03S15L10-30 (310) Safety caution nameplate 419 (516) φ28 hole (Power cable port) Oil sampling port/ Oil drain port: Rc½ 20 10 85 Wing bolt for fastening during transportation (at 1 location on the back) (To be removed before operation) 30 30 530 700 25 85 2-M8 (through hole) Tapped holes for mounting the foundation plate (at 4 locations) (50) 70 70 95 Bolt Caution nameplate 40 8 (260) 2 344 Unit type 1-1 Safety caution nameplate (109) 45 30 ******** Unit nameplate 45 (220) Suction air (246) (466) (421) (83) 155 450 500 (550) (580) 26 Super Unit [Single pump type] Maximum operating pressure Maximum flow rate 10 MPa 30 L/min Pressure – Flow rate characteristics (Representative) 90 Model code 80 SUTS3010-30 Flow rate (L/min) 70 60 50 40 30 SUT SUT SUTS3010 S3010 S3010 20 SUT SUT S1510 S1510 SUTS1510 10 1 Tankless type 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: Unit type Specifications 5 L/min maximum Model Pump unit Tankless type Unit type SUT00S3010-30 SUT03S3010-30 Maximum flow rate (theoretical value; L/min) *1 25.6 Maximum operating pressure (MPa) 10.0 Operating flow rate adjustment range (L/min) 3.4 to 25.6 Operating pressure adjustment range (MPa) 1.5 to 10.0 Motor capacity Motor capacity (equivalent kW) Equivalent to 3.7 kW Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%) AC3 φ200V (50 Hz) 18.4 Rated current (A) AC3 φ200V (60 Hz) 18.4 AC3 φ220V (60 Hz) 16.9 20 Power source breaker setting (A) External input signal External output signal Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load) Mass (kg) Operating conditions 5 channels 46 64 Usable oil *2 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum Operating hydraulic oil temperature (in tank) 0 to 60°C (Recommended operating temperature range: 15 to 50°C) Operating ambient temperature 0 to 40°C Storage ambient temperature –20 to 60°C Operating ambient humidity 85% RH max. (no condensation) Installation site Indoors (Be sure to secure the unit with bolts.) Others Tank capacity (L) Standard coating color • Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. • Make sure that the electrical wiring meets the requirements of European Standard EN60204-1. • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life. To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function. • Be sure to connect the ground terminal. − 30 Ivory white (Munsell code 5Y7.5/1) Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower. *3: The unit incorporates a safety valve. *4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 45. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. 27 External dimension diagram Tankless type Pressure indication and operation panel 1 1-2 Controller 1 2 AC fan 1 3 Base 1 (202) Quantity Inverter driven motor pump (294) Name 1-1 4-φ10 holes (for fixing bolts) (M8 bolts recommended) (87) 15 Part No. 384 SUT00S3010-30 354 15 P Rc⅜ (Fitted with a vinyl cap at shipment) 15 490 15 520 φ28 hole (Power cable port) φ21 hole (Signal cable port) 1-2 DR Rc⅜ (Fitted with a vinyl cap at shipment) ******** Unit nameplate 2 45 324 30 30 384 Suction port: G¾ 30 (Fitted with a vinyl cap at shipment) 3 460 520 Unit type DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) 135 545 (175) 150 SUT03S3010-30 50: 170 42 92 (75) Part No. Name Quantity 1 Oil tank 1 2 Suction strainer 1 3 Stop valve 1 4 Oil level gauge 1 5 Oil filler port-cum-air breather 1 6-1 Inverter driven motor pump 1 6-2 Controller 1 7 Oil cooler 1 8 AC fan 1 100 4-M8 (Manifold bracket mount) T Rc1 (Fitted with a vinyl cap at shipment) Optional port: Rp⅜ Optional port: Rp½ 3 140 P Rc⅜ (Fitted with a vinyl cap at shipment) Pressure indication and operation panel (40) Foundation plate (Option) (E-SUTPLATE-2) 196 (620) 4-φ15 holes (for fixing bolts) (M12 bolts recommended) (40) Specifications and external dimension diagram 30 (259) 1-1 Safety caution nameplate (108) 220 Suction air (245) (466) (421) (83) 10 MPa 6-2 Cleaning port φ21 hole (Signal cable port) 5 L/min 20 (309) 6-1 462 Suction air Cleaning port tightening caution nameplate (516) 23 L Lower limit (Red line) SUT03S30L10-30 Unit nameplate 7 1 30 L Upper limit (Yellow line) Safety caution nameplate 419 φ28 hole (Power cable port) 2 20 10 85 Wing bolt for fastening during transportation (at 1 location on the back) (To be removed before operation) 30 30 530 700 25 85 2-M8 (through hole) Tapped holes for mounting the foundation plate (at 4 locations) (50) 70 70 95 Bolt Caution nameplate 40 8 30 4 450 500 (550) 155 Oil sampling port/ Oil drain port: Rc½ (580) 28 Super Unit [Single pump type] Maximum operating pressure Maximum flow rate 16 MPa 15/30 L/min Pressure – Flow rate characteristics (Representative) 90 Model code 80 SUTS1516-30 SUTS3016-30 Flow rate (L/min) 70 60 50 40 30 SUTS3016 S3016 20 SUTS1516 S1516 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pressure (MPa) Tankless type * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: Unit type 5 L/min maximum Tankless type Specifications Model Maximum flow rate (theoretical value; L/min) *1 Unit type SUT00S1516-30 SUT00S3016-30 SUT03S1516-30 SUT06S3016-30 15.2 25.6 15.2 25.6 2.4 to 15.2 3.4 to 25.6 Equivalent to 3.7 kW Equivalent to 5.0 kW Maximum operating pressure (MPa) Pump unit Operating flow rate adjustment range (L/min) 16.0 2.4 to 15.2 3.4 to 25.6 Operating pressure adjustment range (MPa) Motor capacity Motor capacity (equivalent kW) Power supply Motor pump/unit Rated current (A) 1.5 to 16.0 Equivalent to 3.7 kW AC3 φ200V (50 Hz) 15.2 21.4 15.2 21.4 AC3 φ200V (60 Hz) 15.2 21.4 15.2 21.4 AC3 φ220V (60 Hz) 14.6 20.2 14.6 20.2 20 30 20 30 Power source breaker setting (A) 5 channels External input signal External output signal Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load) Mass (kg) Operating conditions Equivalent to 5.0 kW 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%) 46 52 64 Usable oil *2 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum Operating hydraulic oil temperature (in tank) 0 to 60°C (Recommended operating temperature range: 15 to 50°C) Operating ambient temperature 0 to 40°C Storage ambient temperature –20 to 60°C Operating ambient humidity 85% RH max. (no condensation) Installation site Indoors (Be sure to secure the unit with bolts.) Others Tank capacity (L) Standard coating color 83 • Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. • Make sure that the electrical wiring meets the requirements of European Standard EN60204-1. • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life. To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function. • Be sure to connect the ground terminal. − 30 60 Ivory white (Munsell code 5Y7.5/1) Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower. *3: The unit incorporates a safety valve. *4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 45. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. 29 External dimension diagram 15 (202) 354 384 SUT00S1516-30 SUT00S3016-30 P Rc⅜ (Fitted with a vinyl cap at shipment) Pressure indication and operation panel (294) Tankless type Name Quantity 1-1 Inverter driven motor pump 1 1-2 Controller 1 2 AC fan 1 3 Base 1 φ28 hole (Power cable port) φ21 hole (Signal cable port) 15 Part No. 15 4-φ10 holes (for fixing bolts) 15 (M8 bolts recommended) (137) (77) 578 (490) 608 (520) 1-2 DR Rc⅜ (Fitted with a vinyl cap at shipment) 1-1 Safety caution nameplate 2 324 384 30 45 (45) 3 30 30 548 (460) 608 (520) Optional port: Rp½ 135 DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) 545 150 4 Oil level gauge 1 5 Oil filler port-cum-air breather 1 6-1 Inverter driven motor pump 1 6-2 Controller 1 7 Oil cooler 1 8 AC fan 1 4-φ15 holes (for fixing bolts) (M12 bolts recommended) 100 50 (40) φ28 hole (Power cable port) Cleaning port 1 Cleaning port tightening caution nameplate SUT03S15L16-30 Unit nameplate Suction air 8 4 30 L Upper limit (Yellow line) Safety caution nameplate 7 Foundation plate (Option) (E-SUTPLATE-2) (40) 5 6-2 φ21 hole (Signal cable port) 23 L Lower limit (Red line) 6-1 2 Bolt Caution nameplate 20 85 30 30 85 10 530 700 Wing bolt for fastening during transportation (at 1 location on the back) (To be removed before operation) SUT06S3016-30 186 (620) 2-M8 (through hole) Tapped holes for mounting the foundation plate (at 4 locations) DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) 186 4-M8 150 170 (Manifold bracket mount) (185) 85 Name Quantity 1 Oil tank 1 T Rc¾ (Plugged at shipment) 2 Suction strainer 1 Optional port: Rp⅜ 3 Stop valve 1 Optional port: Rp½ 4 Oil level gauge 1 5 Oil filler port-cum-air breather 1 6-1 Inverter driven motor pump 1 6-2 Controller 1 7 Oil cooler 1 360 110 Part No. 100 50 42 37 T Rc1 (Fitted with a vinyl cap at shipment) 155 450 500 Oil sampling port/ Oil drain port: Rc½ 16 3 MPa P Rc⅜ (Fitted with a vinyl cap at shipment) Pressure indication and operation panel 4-φ15 holes (for fixing bolts) (M12 bolts recommended) (40) (620) 9 Foundation plate (Option) (E-SUTPLATE-2) (40) 6-2 15/ 30 4 5 Safety caution nameplate SUT06S30L16-30 7 Cleaning port tightening caution nameplate Suction air L/min 309 2 20 10 85 530 (707) 30 30 85 2-M8 (through hole) Tapped holes for mounting the foundation plate (at 4 locations) (50) 70 95 Bolt Caution nameplate 25 Wing bolt for fastening during transportation (at 1 location on the back) (To be removed before operation) 60 L Upper limit (Yellow line) 45 L Lower limit (Red line) Cleaning port 1 8 70 1 6-1 20 Return filter Unit nameplate 1 40 9 AC fan 648 595 8 Specifications and external dimension diagram 1 639 Stop valve 462 3 Pressure indication and operation panel (50) 1 70 Suction strainer (309) 2 P Rc⅜ (Fitted with a vinyl cap at shipment) (516) 1 419 Oil tank 95 1 3 140 Quantity 70 Name 40 Part No. T Rc1 (Fitted with a vinyl cap at shipment) Optional port: Rp⅜ 20 SUT03S1516-30 Suction port: G¾ (Fitted with a vinyl cap at shipment) (): Dimensions for SUT00S1516-30 4-M8 (Manifold bracket mount) 170 92 42 (175) (75) 30 25 Unit type (259) ******** Unit nameplate (245) 220 Suction air (108) (466) (421) (133) (73) 450 500 155 Oil sampling port/ Oil drain port: Rc½ 30 Super Unit [Double pump type] Maximum operating pressure Maximum flow rate 16 MPa 40 L/min Pressure – Flow rate characteristics (Representative) 110 100 Model code 90 SUTD4016-30 Flow rate (L/min) 80 70 60 50 40 30 20 10 0 Tankless type 0 5 10 15 20 Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: Unit type 8 L/min maximum Specifications Model Pump unit Motor capacity Power supply Rated current (A) Tankless type Unit type SUT00D4016-30 SUT06D4016-30 Maximum flow rate (theoretical value; L/min) *1 41.0 Maximum operating pressure (MPa) 15.7 Operating flow rate adjustment range (L/min) 5.4 to 41.0 Operating pressure adjustment range (MPa) 1.5 to 15.7 Motor capacity (equivalent kW) Equivalent to 3.7 kW Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%) AC3 φ200V (50 Hz) 17.9 AC3 φ200V (60 Hz) 17.7 AC3 φ220V (60 Hz) 16.5 Power source breaker setting (A) External input signal External output signal Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load) Mass (kg) Operating conditions 20 5 channels 53 94 Usable oil *2 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum Operating hydraulic oil temperature (in tank) 0 to 60°C (Recommended operating temperature range: 15 to 50°C) Operating ambient temperature 0 to 40°C Storage ambient temperature –20 to 60°C Operating ambient humidity 85% RH max. (no condensation) Installation site Indoors (Be sure to secure the unit with bolts.) Others Tank capacity (L) Standard coating color • Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. • Make sure that the electrical wiring meets the requirements of European Standard EN60204-1. • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life. To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function. • Be sure to connect the ground terminal. − 60 Ivory white (Munsell code 5Y7.5/1) Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower. *3: The unit incorporates a safety valve. *4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 45. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. 31 External dimension diagram Tankless type Unloading port Rc½ (Fitted with a vinyl cap at shipment) Pressure indication and operation panel P Rc¾ (Fitted with a vinyl cap at shipment) 15 (146) 1 2 AC fan 1 3 Base 1 4 Check valve 1 578 608 φ21 hole (Signal cable port) 1-2 Suction air ******** Unit nameplate (95) 30 (149) 548 608 DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) (85) 100 (320) 50 37 SUT06D4016-30 (311) 100 T Rc¾ (Plugged at shipment) Optional port: Rp⅜ 3 Optional port: Rp½ P Rc¾ (Fitted with a vinyl cap at shipment) Foundation plate (Option) (E-SUTPLATE-2) Pressure indication and operation panel (620) 9 6-2 (40) 10 Name Oil tank Suction strainer Stop valve Oil level gauge Oil filler port-cum-air breather Inverter driven motor pump Controller Oil cooler AC fan Return filter Check valve 4 5 16 1 MPa Safety caution nameplate SUT06D40L16-30 Unit nameplate Cleaning port tightening caution nameplate 6-1 7 60 L Upper limit (Yellow line) 40 45 L Lower limit (Red line) 2 L/min (441) Cleaning port Suction air 20 8 20 85 30 30 85 25 2-M8 (through hole) Tapped holes for mounting the foundation plate (at 4 locations) (50) 70 70 Wing bolt for fastening during transportation (at 1 location on the back) 10 (To be removed before operation) 530 (707) 95 Bolt Caution nameplate 40 648 Quantity 1 1 1 1 1 1 1 1 1 1 1 716 4-φ15 holes (for fixing bolts) (M12 bolts recommended) (40) Part No. 1 2 3 4 5 6-1 6-2 7 8 9 10 639 4-M8 (Manifold bracket mount) 110 42 (194) 170 150 T Rc1 (Fitted with a vinyl cap at shipment) 595 Suction port: Rc1 (Fitted with a vinyl cap at shipment) 30 Specifications and external dimension diagram 45 (93) 3 30 384 Unit type 1-1 Safety caution nameplate 2 220 45 324 DR Rc⅜ (Fitted with a vinyl cap at shipment) (226) (466) (421) 4 30 4-φ10 holes (for fixing bolts) (M8 bolts recommended) 15 (282) φ28 hole (Power cable port) (142) 15 (180) Controller (95) 1 1-2 354 Quantity Inverter driven motor pump (294) Name 1-1 15 Part No. 384 (73) SUT00D4016-30 450 500 155 Oil sampling port/ Oil drain port: Rc½ 32 Super Unit [Double pump type] Maximum operating pressure Maximum flow rate 21 MPa 60 L/min Pressure – Flow rate characteristics (Representative) 110 100 Model code 90 SUTD6021-30 Flow rate (L/min) 80 70 60 50 40 30 20 10 0 0 Tankless type 5 10 15 20 Pressure (MPa) Unit type * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: 6.5 L/min maximum Tankless type Specifications SUT00D6021-30 Model Pump unit Unit type SUT06D6021-30 Maximum flow rate (theoretical value; L/min) *1 61.1 Maximum operating pressure (MPa) 20.6 Operating flow rate adjustment range (L/min) 8.7 to 61.1 Operating pressure adjustment range (MPa) 1.5 to 20.6 SUT10D6021-30 Motor capacity Motor capacity (equivalent kW) Equivalent to 5.0 kW Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%) AC3 φ200V (50 Hz) 22.1 AC3 φ200V (60 Hz) 21.7 AC3 φ220V (60 Hz) 20.2 Rated current (A) Power source breaker setting (A) 30 5 channels External input signal External output signal 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load) Mass (kg) Operating conditions Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel Digital output 58 99 112 Usable oil *2 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum Operating hydraulic oil temperature (in tank) 0 to 60°C (Recommended operating temperature range: 15 to 50°C) Operating ambient temperature 0 to 40°C Storage ambient temperature –20 to 60°C Operating ambient humidity 85% RH max. (no condensation) Installation site Indoors (Be sure to secure the unit with bolts.) Others Tank capacity (L) Standard coating color • Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. • Make sure that the electrical wiring meets the requirements of European Standard EN60204-1. • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life. To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function. • Be sure to connect the ground terminal. − 60 100 Ivory white (Munsell code 5Y7.5/1) Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower. *3: The unit incorporates a safety valve. *4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 45. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. 33 External dimension diagram P Rc¾ (Fitted with a vinyl cap at shipment) 15 (140) 1 DR Rc⅜ (Fitted with a vinyl cap at shipment) (466) Suction air Unit nameplate 2 Safety caution nameplate 245 30 (85) 100 T Rc¾ (Plugged at shipment) 1 Stop valve 1 4 Oil level gauge 1 5 Oil filler port-cum-air breather 1 6-1 Inverter driven motor pump 1 6-2 Controller 1 7 Oil cooler 1 8 AC fan 1 9 Return filter 1 10 Check valve 1 4-φ15 holes (for fixing bolts) (M12 bolts recommended) (40) 10 SUT06D60L21-30 7 1 Oil tank 1 2 Suction strainer 1 3 Stop valve 1 4 Oil level gauge 1 5 Oil filler port-cum-air breather 1 6-1 Inverter driven motor pump 1 6-2 Controller 1 7 Oil cooler 1 8 AC fan 1 9 Return filter 1 10 Check valve 1 Cleaning port tightening caution nameplate 6-1 Suction air 8 Cleaning port 1 2 20 10 85 30 30 85 530 (707) (85) 100 (327) 150 (188) 170 155 Oil sampling port/ Oil drain port: Rc½ 450 500 2-M8 (through hole) Tapped holes for mounting the foundation plate (at 4 locations) 4-M8 (Manifold bracket mount) T Rc¾ (Plugged at shipment) 3 Optional port: Rp⅜ Optional port: Rp½ P Rc¾ (Fitted with a vinyl cap at shipment) 4-φ15 holes (for fixing bolts) (M12 bolts recommended) (40) (620) 21 Foundation plate (Option) (E-SUTPLATE-2) (40) 6-2 9 MPa Cleaning port 4 5 100 L Upper limit (Yellow line) SUT10D60L21-30 Unit nameplate 10 7 Safety caution nameplate 60 L/min 2 Oil sampling port/ Oil drain port: Rc½ 530 (707) 30 30 85 25 20 10 85 2-M8 (through hole) Tapped holes for mounting the foundation plate (at 4 locations) (50) 70 95 Bolt Caution nameplate 70 40 20 8 Wing bolt for fastening during transportation (at 1 location on the back) (To be removed before operation) 1 Cleaning port tightening caution nameplate 6-1 Suction air 76 L Lower limit (Red line) (441) 648 595 45 L Lower limit (Red line) Bolt Caution nameplate Wing bolt for fastening during transportation (at 1 location on the back) (To be removed before operation) T Rc1 (Fitted with a vinyl cap at shipment) 60 L Upper limit (Yellow line) (441) Quantity Safety caution nameplate Unit nameplate 172 167 Name 4 5 110 Part No. Foundation plate (Option) (E-SUTPLATE-2) (40) 6-2 9 DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) SUT10D6021-30 (620) (441) Suction strainer 3 95 2 P Rc¾ (Fitted with a vinyl cap at shipment) 25 1 608 100 50 Oil tank 70 1 (86) (142.5) 3 Optional port: Rp1/2 20 Quantity 40 Name Optional port: Rp3/8 648 595 Part No. 1-1 DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) (327) (188) 4-M8 150 170 (Manifold bracket mount) 100 50 SUT06D6021-30 Suction port: Rc1 (Fitted with a vinyl cap at shipment) 3 42 110 37 T Rc1 (Fitted with a vinyl cap at shipment) ******** 45 (45) 324 384 30 Unit type (180) 4 Specifications and external dimension diagram 1 Unloading port Rc½ (Fitted with a vinyl cap at shipment) 1-2 (282) Base Check valve 4-φ10 holes (for fixing bolts) 15 (M8 bolts recommended) (136) 578 608 639 716 3 4 Pressure indication and operation panel 15 639 716 1 (95) AC fan φ21 hole (Signal cable port) (226) 2 φ28 hole (Power cable port) (95) 1 (50) Controller 70 1 1-2 (311) Quantity Inverter driven motor pump 15 Name 1-1 (421) Part No. 354 384 SUT00D6021-30 (294) (73) Tankless type 450 580 630 155 50 80 34 Super Unit [Double pump type] Maximum operating pressure Maximum flow rate 21 MPa 80 L/min Pressure – Flow rate characteristics (Representative) 110 100 Model code 90 SUTD8021-30 Flow rate (L/min) 80 70 60 50 40 30 20 10 0 Tankless type 0 5 10 15 20 Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: Unit type 14 L/min maximum Tankless type Specifications SUT00D8021-30 Model Pump unit Unit type SUT10D8021-30 Maximum flow rate (theoretical value; L/min) *1 83.0 Maximum operating pressure (MPa) 20.6 Operating flow rate adjustment range (L/min) 11.6 to 83.0 Operating pressure adjustment range (MPa) 1.5 to 20.6 SUT16D8021-30 Motor capacity Motor capacity (equivalent kW) Equivalent to 7.0 kW Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%) AC3 φ200V (50 Hz) 25.5 AC3 φ200V (60 Hz) 24.8 AC3 φ220V (60 Hz) 22.7 Rated current (A) Power source breaker setting (A) 50 5 channels External input signal External output signal Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load) Mass (kg) Usable oil *2 72 Operating hydraulic oil temperature (in tank) Operating conditions 133 0 to 60°C (Recommended operating temperature range: 15 to 50°C) Operating ambient temperature 0 to 40°C Storage ambient temperature –20 to 60°C Operating ambient humidity 85% RH max. (no condensation) Installation site Indoors (Be sure to secure the unit with bolts.) Others Tank capacity (L) Standard coating color 145 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum • Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. • Make sure that the electrical wiring meets the requirements of European Standard EN60204-1. • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life. To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function. • Be sure to connect the ground terminal. − 100 160 Ivory white (Munsell code 5Y7.5/1) Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower. *3: The unit incorporates a safety valve. *4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 45. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. 35 External dimension diagram Motor cable Pressure indication and operation panel 15 Tankless type (139) 4 P Rc¾ (Fitted with a vinyl cap at shipment) Unloading port: Rc½ (Fitted with a vinyl cap at shipment) 1 1-2 Controller 1 2 AC fan 1 3 Base 1 4 Check valve 1 4-φ10 holes (for fixing bolts) (M8 bolts recommended) 15 (97) 15 600 (60) 630 (196) Quantity Inverter driven motor pump (125) Name 1-1 354 294 Part No. 384 SUT00D8021-30 15 1-2 Suction air (90) Transportation nameplate 30 (142) 3 30 570 Suction port: Rc1 (Plugged (with O-ring) at shipment) 30 Wing bolt for fastening during transportation (2 locations) (To be removed before operation) (85) 150 (188) 170 150 (651) (441) 4-M8 (Manifold bracket mount) T Rc1-¼ (Plugged at shipment) DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) 3 Optional port: Rp⅜ Optional port: Rp½ P Rc¾ (Fitted with a vinyl cap at shipment) Part No. 1 2 3 4 5 6-1 6-2 7 8 9 10 Name Oil tank Suction strainer Stop valve Oil level gauge Oil filler port-cum-air breather Inverter driven motor pump Controller Oil cooler AC fan Return filter Check valve Foundation plate (Option) (E-SUTPLATE-2) (40) (620) 9 Cleaning port 4 5 6-2 10 1 Cleaning port tightening caution nameplate 8 2 Oil sampling port/ Oil drain port: Rc½ 20 Suction air 80 L/min 20 85 10 530 700 (188) (895) 30 30 85 25 2-M8 (through hole) Tapped holes for mounting the foundation plate (at 4 locations) (50) 70 70 95 Bolt Caution nameplate 40 (216) (441) 595 MPa 124 L (76 L) Lower limit (Red line) 7 6-1 21 164 L (100 L) Upper limit (Yellow line) SUT16D80L21-30 Unit nameplate Safety caution nameplate 754 4-φ15 holes (for fixing bolts) (M12 bolts recommended) (40) Wing bolt for fastening during transportation (at 1 location on the back) (To be removed before operation) Quantity 1 1 1 1 1 1 1 1 1 1 1 (647) 382 (172) SUT10D8021-30 SUT16D8021-30 100 50 17 T Rc1-½ (Fitted with a vinyl cap at shipment) 700 (327) 100 Specifications and external dimension diagram Unit type 671 311 258 1-1 2 45 324 (299) (72) Safety caution nameplate 30 (408) Unit nameplate 483 (441) 0 DR Rc⅜ (Fitted with a vinyl cap at shipment) 450 155 50 290 (80) 790 (580) 840 (630) (): Dimensions for SUT16D8021-30 36 Super Unit [Double pump type] Maximum operating pressure Maximum flow rate 21 MPa 110 L/min Pressure – Flow rate characteristics (Representative) 110 100 Model code 90 SUT00D11021-30 P-SUT20D11KW-30 Flow rate (L/min) 80 70 60 50 40 30 20 Tankless type 10 0 0 5 10 15 20 Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: Unit type Specifications 16 L/min maximum Model Pump unit Tankless type Unit type SUT00D11021-30 P-SUT20D11KW-30 Maximum flow rate (theoretical value; L/min) *1 110 Maximum operating pressure (MPa) 20.6 Operating flow rate adjustment range (L/min) 13.3 to 110 Operating pressure adjustment range (MPa) 1.5 to 20.6 Motor capacity Motor capacity (equivalent kW) Equivalent to 11 kW Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%) AC3 φ200V (50 Hz) 38.3 AC3 φ200V (60 Hz) 37.8 AC3 φ220V (60 Hz) 34.9 Rated current (A) Power source breaker setting (A) External input signal External output signal Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load) Mass (kg) Operating conditions 75 5 channels 112 360 Usable oil *2 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum Operating hydraulic oil temperature (in tank) 0 to 60°C (Recommended operating temperature range: 15 to 50°C) Operating ambient temperature 0 to 40°C Storage ambient temperature –20 to 60°C Operating ambient humidity 85% RH max. (no condensation) Installation site Indoors (Be sure to secure the unit with bolts.) Others Tank capacity (L) Standard coating color • Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. • Make sure that the electrical wiring meets the requirements of European Standard EN60204-1. • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life. To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function. • Be sure to connect the ground terminal. − 200 Ivory white (Munsell code 5Y7.5/1) Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower. *3: The unit incorporates a safety valve. *4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 45. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. 37 External dimension diagram Tankless type Suction port: Rc1 ¼ 819 SUT00D11021-30 134 151 (Refer to Page 22 for the external dimensions of the controller) Motor wiring port (φ28) AC fan, thermistor wiring port (21) Drain port Rc⅜ 323 168 117 204 496 42 118 19 Unloading port Rc¾ 199 Discharge port Rc1−¼ 15 108 170 24: 3 112 170 207 228 314 Suction air 108 76.5 4-14.5 (installation) 95.5 132.5 228 275 241 Unit type Drain port: Rc¾ (Fitted with plastic plug) 288 43 670 P-SUT20D11KW-30 Tank 2: Rc1 (Fitted with plastic plug) 250 5 (982) 352 90 80 120 Part No. 1 2-1 2-2 3 4 5 6 7 8 9 10 11 12 13 14 600 4 (10) G1/2 DAIKIN 2-1 6 8 7 14 13 3 Super Unit switch board Tank 1: Rc1-½ (Fitted with plastic plug) 3 OIL HYDRAULIC UNIT 850 Unit nameplate 200 L DAIKIN INDUSTRIES,LTD. MPa Upper limit: 200 L Lower limit: 165 L Oil level gauge guard 1,150 Thermometer 1 MADE IN JAPAN 110 942 866 ■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■ ■■■■■■■■■■■■ ■■■■■■■■■■■■ 21 Safety caution nameplate Leak test by fil ing water Certificate nameplate Suction air Discharge port: Rc1 (Fitted with plastic plug) 920 10 Quantity 1 1 1 2 1 1 1 1 1 1 1 6 1 1 1 L/min DAIKIN 11 210 300 9 210 2-2 Name Oil tank Motor pump Surge cutting block Oil level gauge Oil filler port-cum-air breather Suction strainer Return filter Oil cooler Pressure gauge Thermometer Outlet block Vibration-absorbing rubber Foundation plate Fan motor Electrical cabinet Specifications and external dimension diagram 1,376 1,088 1,002 43 Wiring port for the user 237 Tank drain port: Rc½ (at 3 locations) (Fitted with high-pressure plug) 155 544 838 38 Part names, functions, and the operation of the operation panel Using the key switches on the Super Unit controller, you can monitor the pressure and flow rate and set or change parameters. Outline of Functions NO. Item Description [MODE] key Selects the operation mode. [DOWN] key Decrements a value set for the operation mode/monitor mode/data. [UP] key Increments a value set for the operation mode/monitor mode/data. [ENT] key Confirms the edited operation mode/monitor mode/data. Data display Normal mode: Displays the actual pressure or alarm code. Monitor mode: Displays the pressure switch setting, each pressure setting, each flow rate setting, the actual flow rate, or the actual rotation speed. Setting mode: Set or change the pressure, flow rate, or other parameters. Alarm mode: Check the alarm history. Communication setting mode: Change communication settings. Shifting between Modes To return to the monitor mode or normal mode from other modes, press the key. To go to the setting mode or alarm mode, press and hold down a combination of keys for 2 seconds. Turn on the power Normal mode Hold down for more than two seconds. Monitor mode 39 Hold down for more than two seconds. Setting mode Communication setting mode Hold down for more than two seconds. Alarm mode Monitor mode The following items can be checked in the monitor mode. Item No. Name Unit MPa n00 *1 Pressure switch setting n01 *1 Pressure setting n02 Flow rate setting L/min n03 Flow rate L/min ×10PSI MPa n04 *2 Latest alarm code n05 Rotation speed ×10PSI — ×10min−1 Description [When the PSI unit is selected: ×10 PSI] Displays the pressure switch setting. [When the PSI unit is selected: ×10 PSI] Alternately displays the high (single flow) and low (combination flow) pressure settings for the current P-Q selection number. Alternately displays the high (single flow) and low (combination flow) flow rate settings for the current P-Q selection number. Displays the current flow rate. Displays the alarm code of the alarm that occurred most recently. The current power ON count can be checked by pressing the key. Press the key to check how many times the power has been turned on so far. Displays the current rotation speed of the motor. [SUTD] Displays the solenoid valve switching status: “Low pressure [L]” (combination flow) or “High pressure [H]”(single flow), and the P-Q selection number. Example: Operation status n07 Reverse rotations at power OFF n08 Regenerative load integration ratio n10 n11 min−1 Combination flow (low pressure) - P-Q selection No. 1 [SUTS] Displays the low pressure status [L] and P-Q selection number or the selected P-Q selection number only. Example: Combination flow (low pressure) - P-Q selection No. 1 Example: P-Q selection No. 2 Displays the total number of rotations of the motor when it rotates in the reverse direction due to reverse flow from the load when the power supply for the unit is turned OFF. This value is used to estimate the machine load volume. % Displays the regenerative load integration ratio of the current regenerative braking resistance. Motor temperature °C Displays the temperature of the motor. Heat emission fin temperature °C Displays the temperature of the heat emission fins. n12 Main circuit voltage V Displays the controller’s internal circuit voltage. The indicated voltage is a value equivalent to "power supply voltage 2". The main circuit voltage may vary depending on the operating conditions and momentarily exceed 350 V due to a regenerative current during deceleration and other operations. However, this is not abnormal. n13 Analog input voltage 1 V Displays the input voltage at analog input terminal AIN1. n14 Analog input voltage 2 V Displays the input voltage at analog input terminal AIN2. n15 Analog output voltage 1 V Displays the output voltage at analog output terminal AO1. n16 Analog output voltage 2 V Displays the output voltage at analog output terminal AO2. *1: The default setting is displayed in MPa (standard display unit). If you change the display unit to PSI, ensure that you indicate in some manner that the monitor value is displayed using the PSI unit (attach a label, etc). However, use of the PSI unit in Japan is subject to punishment under the Measurement Law. Users should supply their own unit indication labels. *2: You can check the current power ON count by pressing the key when an alarm code is displayed. For details on alarm codes, refer to the alarm descriptions in the Operation Manual. Setting mode The following data can be set in the setting mode. For details on the settings, refer to the Operation Manual of the relevant model since they vary depending on the model. The pressure, flow rate, acceleration time, deceleration time, etc., to be set for multi-stage pressure/flow rate control Enable/disable setting of pressure switch functions Part names, functions, and the operation of the operation panel n06 — Dry run judging pressure, time, etc. Various control gains Display unit selection 40 Power supply and I/O signal cables SUTS1507-30, SUTS3007-30, SUTS1510-30 SUTS4007-30, SUTS6007-30, SUTS3010-30 SUTS1516-30, SUTS3016-30 SUTD4016-30, SUTD6021-30 Internal terminal layout (with the controller cover open) I/O signal terminal block Ground terminal Recommended cable clamp OA-W1611 (I/O signal cables) Recommended cable clamp OA-W2216 (power cables) Power supply connection terminal block SUTS8007-30, SUTD8021-30 Internal terminal layout (with the controller cover open) I/O signal terminal block Power supply connection terminal block Ground terminal for power cable Recommended cable clamp OA-W2216 (power cables) Recommended cable clamp OA-W1611 (I/O signal cables) * Main power supply connections: Connect a 3-phase AC power supply (200 V/50 Hz, 200 V/60 Hz, or 220 V/60 Hz) to the power supply terminals (L1, L2 and L3), and connect a ground cable to the ground terminal. * I/O signal connections: Connect digital input terminals, digital output terminals, and contact output terminals as shown on Page 42. 41 Power supply and I/O signal cables SUT00S11007-30, SUT00D11021-30, P-SUT20D11KW-30 User I/O terminal block (M3) Encoder Motor thermistor Pressure sensor I/O signal FG +5V Z+ B+ A+ FG GND ZDANGER WARNING B- 感電のおそれがあります。 A- 通電中及び電源遮断後5分以内は ターミナルカバーを開けないで下さい。 THM- May cause electric shock. THM+ AGND AO2 (QO) AGND AO1 (PO) Disconnect all power before opening terminal cover of unit. Wait 5 minutes until DC Bus capacitors dischange. DAIKIN INDUSTRIES, LTD. AGND AIN2 (QI) AGND AIN1 (PI) AGND P_S A5V ALM_C ALM_B ALM_A DOCOM DO7 DO6 DO5 DO4 DO3 DO1 DI7 DI5 DI3 DI1 DGND TxD FG MFG No.: INSULATION CLASS: F MASS kg V Hz A MAX. FLOW : L/min 50: 3φ 200 60 MAX.PRESSURE : MPa 3φ 200 60 3φ 220 DO2 DI8 DI6 DI4 DI2 DICOM RxD FG Main power supply terminal block (M5) Main power supply DC reactor Regenerative resistor Motor output Solenoid valve terminal block (M4) Solenoid valve power supply AC fan power supply Digital input signal Digital output signal External control equipment External power supply (DC 24 V) PF DAIKIN INDUSTRIES,LTD. MADE IN JAPAN ICOM DIN1 External power supply (DC 24 V) 4.7 kΩ DO1 2.2 kΩ 50 mA maximum Load 4.7 kΩ DO2 2.2 kΩ Load OCOM 4.7 kΩ DIN3 2.2 kΩ * The digital output common terminal can be either positive or negative. * Prepare an external power supply (DC 24 V ± 1 V, 0.5 A or more). * The maximum output current of the output circuit is 50 mA per channel. 4.7 kΩ DIN4 2.2 kΩ DIN5 2.2 kΩ 5 mA * The digital input common terminal can be either positive or negative. * Prepare an external power supply (DC 24 V ± 1 V, 0.5 A or more). * The current of the input circuit is 5 mA per channel. Analog input signal Analog input 1 0 to 10 V Analog input 2 0 to 10 V * The switching capacity of the contact output is DC 30 V, 0.5 A (at resistance load). Contact output a * The minimum applicable load of COM the contact output is DC 10 mV, Contact output b 10 µA, but this is only a guide to the lower limit where switching Common is possible with a minute load. The value varies depending on the switching frequency, environmental (The above figure shows the normal status of the relay contacts.) conditions, etc., so it is advisable to check the actual value. Contact output signal 4.7 kΩ Power supply and I/O signal cables DIN2 Analog output signal AIN1 AO1 AGND AGND AIN2 AO2 AGND AGND V Analog output 1 −10 to 10 V V Analog output 2 −10 to 10 V 42 Harness specifications (Recommended parts) Power supply cable Model I/O signal cable Cable size Recommended cable Recommended crimp terminal SUTS1507 SUTS3007 SUTS1510 SUTS3010 SUTS1516 SUTS3016 2.5 mm2 or more (AWG14 or larger size) CE362 2.5 mm2 × 4 wires (KURAMO ELECTRIC) RBV2-4 SUTS6007 4.0 mm2 or more (AWG12 or larger size) CE362 4.0 mm2 × 4 wires (KURAMO ELECTRIC) RBV5.5-4 OA-W2216 (OHM ELECTRIC) Applicable cable outer diameter: φ13 to φ16 SUTS8007 6.0 mm2 or more (AWG10 or larger size) CE362 6.0 mm2 × 4 wires (KURAMO ELECTRIC) RBV5.5-5 OA-W2219 (OHM ELECTRIC) Applicable cable outer diameter: φ15 to φ19 SUTD4016 2.5 mm or more (AWG14 or larger size) RBV2-4 OA-W2216 (OHM ELECTRIC) Applicable cable outer diameter: φ13 to φ16 2 CE362 2.5 mm2 × 4 wires (KURAMO ELECTRIC) SUTD6021 4.0 mm2 or more (AWG12 or larger size) SUTD8021 6.0 mm or more (AWG10 or larger size) CE362 6.0 mm2 × 4 wires (KURAMO ELECTRIC) SUT00S11007 SUT00D11021 10 mm2 or more CE362 10.0 mm2 × 4 wires (KURAMO ELECTRIC) CE362 4.0 mm2 × 4 wires (KURAMO ELECTRIC) RBV5.5-5 2 Recommended cable clamp OA-W2213 (OHM ELECTRIC) Applicable cable outer diameter: φ9 to φ13 Cable size OA-W2216 (OHM ELECTRIC) Applicable cable outer diameter: φ13 to φ16 Recommended cable clamp KVC-36SB 0.3 - 0.5 mm2 OA-W1611 (OHM ELECTRIC) Applicable cable outer diameter: φ9 to φ11 0.3 to 0.5 mm2 (AWG20 to 22) 0.3 to 1.0 mm2 (AWG16 to 22) 0.3 to 0.5 mm2 (AWG20 to 22) OA-W2219 (OHM ELECTRIC) Applicable cable outer diameter: φ15 to φ19 0.3 to 1.0 mm2 (AWG16 to 22) - 0.3 to 0.5 mm2 (AWG) R8-5 Recommended cable - Power supply cable for solenoid valve output Model SUT00D11021 Cable size Recommended cable Recommended crimp terminal Recommended cable clamp - CE362 0.5 mm2 × 3 wires (KURAMO ELECTRIC) (Controller side) RBA1.25-4 (Solenoid valve side) RBA1.25-3 - Motor cable Model SUT00D11021 AC fan power supply cable Recommended cable Recommended crimp terminal Recommended cable CE362 10 mm2 × 4 wires (KURAMO ELECTRIC) (Controller side) R8-5 (Motor side) R8-6 CE362 0.5 mm2 × 3 wires (KURAMO ELECTRIC) Motor thermistor harness Recommended crimp terminal Recommended cable (Controller side) KVC-36SB 0.3 to 0.5 mm2 (KURAMO ELECTRIC) RBA1.25-3 Recommended crimp terminal (Controller side) RBA1.25-3 (Motor side) RBA1.25-3.5 Specifications of harnesses for the SUT00D11021 If preparing your own harnesses, make the harness length no greater than 5 m. Terminal specifications 43 Name Model Encoder harness PM-SEH05-P22-A09R Pressure sensor harness PM-SPH05 (with a ferrite core) SUT unit Controller side Cable specifications Cable type Cable gauge Ferrite core Cable (recommended) length Contact 170366-1 Housing 172169-1 (All manufactured by AMP) Round terminal with a KVC-36SB vinyl insulation (KURAMO ELECTRIC) sheath (PBA1.25-3) AWG22 5m Not required Contact Rubber cap Housing Double lock plate Round terminal with a KVC-36SB vinyl insulation (KURAMO ELECTRIC) sheath (PBA1.25-3) AWG20 5m TFCM-16-8-16 (Kitagawa Industries) or equivalent 171630-1 172746-1 174357-2 1-174358-1 (All manufactured by AMP) Option The following optional parts can be purchased separately from the Super Unit. These parts are to be mounted by the user. Base plate set These parts are used to fasten the Super Unit to a floor surface. The bolts for mounting the unit to the floor should be prepared by the user. Model Applicable model Unit type: Single pump type Unit type: Double pump type SUT03S1507-30 SUT03S3007-30 SUT06S6007-30 SUT10S8007-30 SUT03S1510-30 SUT03S3010-30 SUT03S1516-30 SUT03S4007-30 SUT06S3016-30 E-SUTPLATE-2 Color Accessories (1) Base plate (4 pcs) SUT06D4016-30 SUT10D4016-30 SUT06D6021-30 SUT10D6021-30 SUT10D8021-30 SUT16D8021-30 Ivory white (Munsell code 5Y7.5/1) (2) Tank fastening bolt (8 pcs) (3) Plain and spring washers for the above parts (8 pcs each) Example of installation 25 Base plate dimensions 25 25 2-C3 φ15 hole 10 30 10 2-φ10 holes 25 40 t3.2 2-C3 50: 40 Level switch Model Operating voltage Operating current Contact resistance Protection class E-DLSN-130L-A-10 24 V DC/AC 0.05 A DC/AC 1 Ω maximum IP65 SUT03 (with 30 L tank) 21 L maximum SUT06 (with 60 L tank) 50 L maximum SUT10 (with 100 L tank) 83 L maximum SUT16 (with 160 L tank) 135 L maximum Closed Closed Closed Closed N/A E-DLSN-130L-B-10 24 V DC/AC 0.05 A DC/AC 1 Ω maximum IP65 SUT03 (with 30 L tank) 21 L maximum SUT06 (with 60 L tank) 50 L maximum SUT10 (with 100 L tank) 83 L maximum SUT16 (with 160 L tank) 135 L maximum Open Open Open Open N/A E-DLSN-170L-A-10 24 V DC/AC 0.05 A DC/AC 1 Ω maximum IP65 SUT06 (with 60 L tank) 45 L maximum Closed SUT10 (with 100 L tank) 75 L maximum Closed SUT16 (with 160 L tank) 123 L maximum Closed N/A E-DLSN-170L-B-10 24 V DC/AC 0.05 A DC/AC 1 Ω maximum IP65 SUT06 (with 60 L tank) 45 L maximum Open SUT10 (with 100 L tank) 75 L maximum Open SUT16 (with 160 L tank) 123 L maximum Open N/A CE standard * Directly mountable on the Rc1/2 option port on the top face of each tank. Temperature switch Model Operating voltage Operating current Contact resistance Protection class Oil level triggering alarms CE standard E-MQT83PD-L60X1-10 AC 100 V DC 24 V AC 2 A DC 50 mA 30 mΩ maximum IP65 60°C N/A * Directly mountable on the Rc3/8 option port on the top face of each tank. Thermometer Model E-RBT-100-200L Micro separator Thermometer specification Bimetal type Temperature indication range Size Model Size 0 to 100°C φ45 E-MSB-110 110 × 60 × 30 Specifications of harnesses (Recommended parts) Option Oil level triggering alarms 44 Method of selection How to Select a SUPER UNIT 1. Determine the cylinder that requires the maximum pressure and flow rate. 2. To operate several cylinders simultaneously, calculate the pump discharge rate required for each circuit. Refer to (6) below. (1) Calculation of cylinder output (see the calculation formula for each load) Calculate the force F (N) required for the cylinder. (2) Calculation of the required pressure (Pu) of the cylinder (Pu = F/A) Based on the force (F) and pressurized area (A), calculate the net pressure (Pu; MPa) required for the cylinder. (3) Calculation of the required pressure (Pp) of the pump (Pp = Pu + P) Calculate the pressure Pp (MPa) required for the pump by adding the total pressure loss P to the pressure (Pu) required for the cylinder. (4) Calculation of the net required discharge rate (Qc) of the cylinder (Qc = A × V × 0.06) Based on the cylinder speed (V) and pressurized area (A), calculate the net discharge rate (Qc; L/min) of the cylinder. (5) Calculation of the required discharge rate (Qp) of the pump Add the flow rate loss to the net discharge rate (Qc) of the cylinder. (6) Total required discharge rate (Qp) of the pump Calculate the maximum required discharge rate of the pump by totaling the (Qp) values of the cylinders to be simultaneously operated. F: Load (N) A: Pressurized area of the cylinder (cm2) * The pressurized area varies depending on the specifications of the hydraulic cylinder. P: Valve pressure loss + Piping pressure loss (MPa) V: Speed (cm/sec) g1: Flow rate loss (L/min) Set the flow rate loss according to (1) the pressure reducing valve type, and (2) the pressure reducing valve diameter. 3. Based on the maximum required pump pressure (Pp) and pump discharge rate (Qp), select the SUT series unit size. By referring to the "Pressure – Flow Rate Characteristics" charts (on Pages 11 and 12), select a model such that the Pu and Qc values of all cylinders fall within the P-Q curve. (Reference) Load analysis (cylinder output) Calculate the cylinder force (Fs) depending on the operation and load type. Operation/Load type Load requiring a pushing or pulling force (Examples: pressing, forming, cutting, shearing) A. Mechanical load B. Load driven under its own weight load Load driven by negative force in a cylinder pushing or pulling operation to move a driven target (e.g., table lifter) up/down. W Load whose direction of force changes (+ → −) (Examples: down ender, workpiece rotation) C. Inverting load D. Resistance load E. Inertial load 45 Calculation of force (Fs) W W W W Load driven by positive sliding force in both forward and backward operation (Examples: pusher, table slide) Load driven by large inertial force in high-speed operation with a heavy object (Example: Coil car travel) User-defined value (Generally specified in tons) Fs = W The required force is equal to the weight of the driven target. Fs = I1/I2 × W W I2 I1 = L1 × cosθ L1 θ L2 I2 = L2 × cosθ Fs = W × μ Friction coefficient { Standard setting: 0.3 Other cases: user-defined value Fs = W × μ Friction coefficient { Standard setting: 0.1 Other cases: user-defined value θ I1 Handling The following are the minimum requirements for use of the Super Unit. For details, refer to the unit’s Instruction Manual. Ambient conditions 1. Ambient temperature: 0 to 40°C, ambient humidity: 85%RH maximum (with no condensation), altitude: 1,000 m maximum, to be used indoors Hydraulic oil 1. Use general petroleum hydraulic oil (R&O) or wear-resistant hydraulic oil. Hydrous or synthetic oil cannot be used. 2. Use hydraulic oil equivalent to ISO VG32 to 68 and operate the unit within an oil viscosity range from 15 to 400 mm2/s and a tank oil temperature from 0 to 60°C. The recommended operating range is from 15 to 50°C (20 to 200 mm2/s). 3. Keep contamination of hydraulic oil within NAS class 9, or NAS class 10 for 7 MPa or lower pressure. Installation and piping 1. This hydraulic unit mounts the motor pump using vibration-absorbing rubber to prevent pump vibration being transmitted to the unit. Use hoses for piping to the unit to provide flexibility. 2. The unit is a stationary type. Fix it with bolts on a level location that is free of vibration. 3. Do not place any obstacles to oil cooler air intake and exhaust within a distance of 100 mm from the intake and exhaust vent of the motor and the oil cooler. Install the unit at a location with good air flow so that heated air can be vented. Take care about the temperature of the intake air: it must satisfy the stipulated condition for ambient temperature (40°C maximum). 4. Use hoses for piping to provide flexibility. 5. Before operating the unit, be sure to remove the wing bolt and spacer for protecting the rubber vibration isolator. If you fail to do so, the noise and vibration may be excessive. 6. Be sure to secure the space required to access the unit during electrical wiring at the noise filter box or control unit side. Electric wiring 1. Install a no-fuse breaker and a ground fault interrupter compliant with European Standard EN60947-2 in the main power supply of this hydraulic unit, to protect the electrical circuits against shorting and overcurrent, and to prevent electric shocks. 2. Use suitable electric cable in accordance with the power supply capacity. 3. Be sure to provide a ground connection with a grounding resistance of 100 Ω maximum, and connect the grounding wire directly with no breaker in the line. 4. Take care not to leave waste metal such as screws and cutting chips, combustible matter such as wood waste or oil, or wiring debris inside the controller. 5. Use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage to the unit. 6. Before accessing the interior of the controller, turn the unit’s power supply OFF. Make sure that the circuit is turned OFF using the circuit breaker for the primary power supply, and then wait at least 5 minutes. Other precautions 2. If failure or malfunction of this unit is expected to cause death or pose a danger to human beings, adopt appropriate safety measures in the facilities. If this unit is used in an important facility, also adopt appropriate safety measures in the facility to ensure that a failure of the equipment will not lead to a serious accident or loss. 3. It takes approximately 3 seconds for this hydraulic unit to start up after being powered ON. Depending on the piping conditions, the unit may take longer to increase the pressure to the pressure switch’s preset level, resulting in pressure switch signal output. In this case, set the machine up so that it will not accept this alarm output during this period. 4. Do not turn the power OFF/ON with the main power breaker frequently. It may damage inverter components. (To start and stop the unit, use the start/stop signal.) Method of selection Handling 1. If a failure occurs in the hydraulic unit, the system indicates an alarm and stops. 46 Osaka Office YODOGAWA PLANT 1-1, Nishi-Hitotsuya, Settsu, Osaka 566-8585, Japan Phone: 81-6-6349-4475 Fax.: 81-6-6349-7862 Home Page: http://www.daikinpmc.com/en/ Contents in this catalog are subject to change for improvement without prior notice. GK244A (2014.03.010) DF.MD.MD