Security Management System - Honeywell Integrated Security
Transcription
Security Management System - Honeywell Integrated Security
Security Management System NEXSENTRY COMMAND CENTER WITH WINDOWS NT OPERATOR STATION & UNIX SERVER SPECIFICATION DATA KEY FEATURES NEXSENTRY COMMAND CENTER represents a major step in the evolution of WSE’s most advanced security management system. Its new, easy-to-use graphical user interface brings the power of this proven security management system within the reach of any operator. Operated using Windows NT Operator Stations and powered by a UNIX server, NexSentry Command Center is a multi-user, multi-tasking security management system that monitors thousands of access points and reports all transactions to one or more security centers in real-time. Since it uses advanced modular architecture, NexSentry Command Center can be easily customized for the specific needs of any application. In its basic configuration, NexSentry Command Center performs the following functions: access control; alarm monitoring; audit trail; reporting; system diagnostics, and; graphical maps. The Maps module gives operators point-and-click monitor and control of an entire security network. System functionality can be expanded by simply adding the modules necessary for specific applications. Optional modules include the following: Photo ID, CCTV, Alarm Networks, HVAC, Elevator Control, Time and Attendance, Guard Tour, Parking Lot and Revenue Control, and Visitor Electronic Directory. • A powerful security management system with virtually unlimited integration and expansion options • Microsoft Windows NT Operator Stations us an intuitive graphical user interface for monitor and control functions • UNIX Server with powerful database, controller, and LAN services • Open architecture database that supports ODBC and SQL • Integration options for photo ID, CCTV, elevator control, guard tour, etc. • Centralized, distributed and remote processing • Support for multiple access control technologies at each door • Multi-tasking and ZOOM feature for switching between screens • User-defined database; system actions by time/event, alarm interrupts and priority routing • Remote diagnostic support and comprehensive on-line help • Full reporting capabilities • Interactive graphical maps - Import CAD/CAM and other graphics formats - Monitor and control with point-andclick interactive icons • Standard Elevator Control module Compliance with industry standard communications and networking protocols gives NexSentry Command Center virtually unlimited expansion potential using LAN/Ethernet, leased telephone lines or dial-up circuits. NexSentry Command Center supports multiple control technologies, including: proximity, keypad, magnetic stripe, smart card, and biometrics. NexSentry Command Center is also compatible with some of the most popular access control units available, including: NexSentry 4100 Series, Alto 818 Series, and SE 422 Series controllers. NexSentry Command Center is available in three versions, depending on the level of complexity of an installation. One Star is ideal for smaller applications, like a single-building facility. Two-Star and ThreeStar are systems that meet the needs of larger, more complex applications, like a multiple-building complex. NexSentry Command Center Servers and Operator Stations are bundled with state-of-the-art CPUs and components that are designed for optimum performance of system software. ® U.S. Registered Trademark , Supports integrated photo ID 92995100005 NEXSENTRY COMMAND CENTER SECURITY MANAGEMENT SYSTEM FEATURES NEXSENTRY COMMAND CENTER uses the most comprehensive Security Management Software available today. Following is a partial list of some of the standard features that are in every version of NexSentry Command Center. The accompanying chart, “System Features”, lists features that are unique to each version of NexSentry Command Center. Available versions: • One Star: smaller applications, like a single-building facility • Two-Star and Three-Star: larger, more complex applications, like a multiplebuilding complex. Bundled systems: State-of-the-art CPUs designed for optimum performance of system software and integrated components Controller support: • NexSentry 4100 Series • Alto 818 Series • SE 422 Series • SE 718 Technology support: • Digital proximity • Analog proximity • Keypad • Magnetic stripe • Smart Card • Biometrics Standard functions: • Graphical user Interface • Menu operation • Access control • System and activity monitoring • Database management • Database reporting • Status and overrides • Custom cardholder PIN • Cardholder database: - User-definable custom cardholder fields • UNIFY Accell relational database with SQL • Maps: - Monitor, control security network through maps - BMP map import - Graphical icons 92995100005 rev. 299bd System networking and expansion: Options: • Local Controllers (LCs) • Remote Location Controllers (RLCs) • Remote Dial-up Interface units (RDI) Network wiring: • LAN/Ethernet • Leased lines • Remote dial-up Real-time monitoring: • Every device on access control system • Communications failures, tampers, power fails, sensor failures, etc., immediately reported as alarm conditions Access Control Smart Failsoft: • Define access privileges as “Off-line (Degraded) Mode Only” • During normal operation, Server makes access decisions • Controller makes access decision when communication is severed Tenant capability: • Multiple simultaneous users (tenants) • No viewing of other tenant information Operations: ZOOM: Look up information in supporting files and dynamically enter the data in another file Installation tools: Allows the installer to easily define components of the system installation tools Diagnostics tools Task and event programming: • Define what happens as a result of an event. • Multiple responses to a single event Anti-Passback: • Each reader/sensor can be assigned to a Passback zone and a direction (in or out) • Prevents multiple entries using single credential, like in parking facilities and high security areas Auto unlock: • Define automatic unlock time periods, based on day and time, for any door desired • System automatically unlocks the specified door at the beginning of the time period and re-locks the door at the end of the time period DATABASE SPECIFICATIONS One-Star ★ Two-Star ★★ Three-Star ★★★ 4 8,000 2,000 99 1,000 2,000,000 unlimited Redundancy only 0 8 128,000 32,000 99 1,000 2,000,000 unlimited 8 16 12 250,000 32,000 99 1,000 2,000,000 Unlimited 16 32 0 Central: 8 Distributed: 16 Central: 64 Distributed: 128 128 Central: 32 Distributed: 64 Central: 256 Distributed: 512 256 Central: 64 Distributed: 128 Central: 512 Distributed: 1,024 Central: 512 Distributed: 512 Central: 64 Distributed: 128 Central: 1,024 Distributed: 2,048 Central: 512 Distributed: 1,024 Central: 2,048 Distributed: 4,096 Central: 1,024 Distributed: 2,048 1,000 1,000 1,000 1,000 1,000 1,000 Access control Terminals Cardholders Access codes Time codes Holidays On-line transaction storage Off-line transaction storage Local Controllers (LCs) Remote Location Controllers (RLCs) Remote Dial-Up Interfaces (RDIs) Access Control Units (without LC, RLC or Dial-up) Doors (without LC, RLC or Dial-up) Alarm Monitoring Monitor points Output relays Reporting & Operating Operators/passwords Floor plan maps 2 NEXSENTRY COMMAND CENTER SECURITY MANAGEMENT SYSTEM Manual unlock: • Unlock any door, or group of doors, from the computer terminal keyboard • Record time, date, and operator’s name Alarm events: • Predefined events considered alarms • Displayed immediately and permanently logged for later reporting • Provides operator instructions, map displays, and alarm annunciation Access tracking: • Traces all access at selected doors or by selected keys • Operator defined buildingclosed times Comprehensive reporting: • Cardholder History Report • Point History Inquiry • Selective Transaction Report • Access Control Archive Report • Passback Level Report • Master File Reports Real time monitoring: • Displays all activity occurring throughout the access control system as it happens • Displays activity graphically on graphical maps Visitor access control: • Tracks visitors • Issue keys before valid date • Deny access after valid date • Trace and report user activity Project scheduling: • Grant or deny additional levels of access to employees based upon a set of clearances established for a specific project. • Provides an additional security clearance that can be controlled by door, time of day, and day of week, and by a date or range of dates Decision Processing: Centralized, Distributed, Deferred • Allows decision-making capabilities to be centralized in Servers, LC and RLC workstations, or distributed to the access control units Two-man rule No access unless two individuals with valid access privileges present their keys OPTIONS In a world with highly sophisticated access control needs, there’s no such thing as a “Typical” installation. This makes it important to install a security management system that does the following: • seamlessly integrates with the security network • is flexible enough to be tailored specifically for the varied needs of the installation • will change and expand as the needs of the organization grow • can easily integrate new technologies as they are introduced CCTV Time and attendance The CCTV module allows CCTV cameras to be activated upon an alarm or when someone presents a card to a reader. User-definable preset position of pan, tilt, and zoom eliminates guard guesswork; but, also allows camera operation by a guard at an Operator Station. Operators can control multiple cameras on any monitor. The Time and Attendance module allows NexSentry Command Center to automate the capture of hours worked, providing error free input data to a payroll system. Elevator Control Elevator Control allows a system to monitor and control access to elevators and/or individual floors. When a cardholder presents a key to a reader inside the elevator, the system will activate only the floor buttons authorized for that person. Guard tour monitoring This level of flexibility is built into NexSentry Command Center through its modular design and open architecture. The Guard Tour module allows a NexSentry Command Center system to be used for defining, scheduling, monitoring and reporting guard tours using both readers and contact input points as tour stations. The following are descriptions of some optional features and applications that can be integrated with a NexSentry Command Center system: Photo ID: NexSentry Imaging Solutions Advanced report generator NexSentry Imaging Solutions seamlessly integrate advanced DataCard photo ID capabilities with NexSentry Command Center. Compliance with industry standard database protocols allows NexSentry Imaging Solutions to share database functions with NexSentry Command Center. An Advanced Report Generator program allows users to create their own custom reports. Audit trail Audit Trail provides a complete history of data changes made to a NexSentry Command Center system by documenting all changes made to the database (excluding system generated transactions or logs). The Audit Trail provides the user with a “before and after” image of the data. SYSTEM MODULARITY NexSentry Command Center’s modular system architecture allows users to add features as their needs grow. It also allows integration of third party applications with WSE’s access control and security management systems 3 Parking and Revenue Control (PARC) PARC allows operators to control access to, and the revenue generated by, a parking facility. PARC supports access control of cardholders and the cashier function normally associated with transient parkers. Redundant system support NexSentry Command Center’s Server/Client architecture allows redundant system support that can accommodate a manual switchover, at which time the pollers will be activated on the Server. Visitor Electronic Directory Visitor Electronic Directory allows NexSentry Command Center to track visitors who are not issued an ID credential. This system also automates the printing of visitor badges but also provides a permanent log of every visitor and who they were visiting. NEXSENTRY COMMAND CENTER SECURITY MANAGEMENT SYSTEM ORDERING INFORMATION USA: 510 360-7902 Intercontinental: 510 360-7894 European: 510 360-7850 Order # Order # Description NexSentry Command Center Security Management System software Software options 92605070000 92605071000 92620070000 92620071000 92630070000 92630071000 92605038000 92610038000 92610040000 92610045000 92605046000 92610076000 92610048000 92610051000 92630051000 NexSentry Command Center One-Star 110V NexSentry Command Center One-Star 220V NexSentry Command Center Two-Star 110V NexSentry Command Center Two-Star 220V NexSentry Command Center Three-Star 110V NexSentry Command Center Three-Star 220V Local Controllers 92610080000 92610081000 92620080000 92620081000 92630080000 92630081000 LC1 Local Controller 110V LC1 Local Controller 220V LC2 Local Controller 110V LC2 Local Controller 220V LC3 Local Controller 110V LC3 Local Controller 220V 92610176000 92630078000 92600022100 92600022110 Remote Location Controller 110V Remote Location Controller 220V Remote Location Controller 110V Remote Location Controller 220V Remote Location Controller 110V Remote Location Controller 220V 92610033000 92610037000 92610032000 92610041000 92610043000 92610044000 92610042000 92610047000 92620052000 92600020000 92600022300 92600020100 92600022200 92600280000 LC Communications Software RLC Communications Software RDI Communications Software NexTerminal with Windows Terminal software support for Ethernet NexTerminal Video Option Hardware for live video terminal PC Based color Windows terminal, 110V Remote Dial-Up Interface 92600750000 Remote Dial-up Unit (RDI) for NSCC Miscellaneous NSCC Hardware 92600310000 92600311000 92600320000 92600380000 92600381000 92600500000 92600510000 92600520000 92600530000 92600540000 Controller Support, NexSentry 4100 Series/ 800 Series/422 Series Controller Support 718P Stellar Support Opto22 Support Vicon CCTV Support Burle CCTV Support American Dynamics CCTV Support Pacom CCTV Support Radionics Receiver Support Recognition Systems Hand Geometry Support WSE 47102 Mission Falls Court Fremont, CA 94539 510 360-7900 510 360-7820 Fax http://www.wse.com Software support for Ethernet LAN Hardware for Ethernet LAN Terminal options Controller support package 92610034000 to NSCC Two-Star to NSCC Three-Star LAN support Communications software 92605027000 92610028000 92610029000 Elevator Control—One-Star Elevator Control—Two-Star, Three-Star Parking Revenue Control Time and Attendance Electronic Directory Guard Tour Two-Man Rule IQ—4 GB tape drive for One-Star IQ—4 GB tape drive for One-, Two-, Three Star Software only upgrades for mixed configurations Remote Location Controllers 92610090000 92610091000 92620090000 92620091000 92630090000 92650091000 Description 8MB Memory Upgrade for CPU 16MB Memory Upgrade for CPU Additional Mux w/8 RS232 Ports Opto22 (16) Slot Controller, 110V Opto22 (16) Slot Controller, 220V Opto 10-32V DC Input Module Opto 4-16V DC Input Module Opto 2.5-28V DC Input Module Opto 5-60V DC Output Module Opto DC Dry Contact Output Module WSE Europe Oestergade 21 DK-4700 Naestved Denmark 45-55-771366 45-55-771235 Fax The future of access control 92995100005 rev. 299bd 4 NEXSENTRY COMMAND CENTER SECURITY MANAGEMENT SYSTEM CONFIGURATION N EXS ENTRY C OMMAND C ENTER is equally at home in a small singlelocation environment as it is in a large multiple-location network. Its architecture provides for a level of performance and range of system sizes unmatched in the access control industry. Systems are easily configured using the basic building blocks listed below. Server The server is the heart of a NexSentry Command Center security management system. A single UNIX-CPU, the server provides all of the capabilities to manage access and alarm activity. A server will download all necessary information for system operation to any attached Local Controllers (LCs), Remote Location Controllers (RLCs) or Remote Dial-up Interfaces (RDIs) and Access Control Units (Controllers). NexTerminal Operator Station System operators monitor and control activity in the access control network using NexTerminal Operator Stations (NexTerminals) that run on Windows NT clients. Because they use an intuitive graphical user interface, NexTerminals allow operators to easily perform all access control and alarm monitoring functions without knowing that a powerful UNIX server is at the heart of the security network. Local Controllers (LCs) LCs support real-time monitoring and decision-making in large scale, high performance or redundant single location systems, while the server retains overall control of file management and reporting. LCs store information about access and alarm events, uploading it to the server upon request. SERVER CONFIGURATION Standard Poller (1) One Star ★ Two Star ★★ Three Star ★★★ 1 4 8 Number of Pollers Supported: Number of Devices per Poller NexSentry 4100 Series/SE 800 Series/SE 422 Distributed Processing NexSentry 4100 Series/SE 800 Series/SE 422 Central Processing Series SE 718P - Central Processing Remote Dial-Up interface Local Controllers (LC) Remote Location Controller (RLC) (1) One ACU poller type is included with each system Optional Controller Support 16 16 16 8 8 8 8 32 0 0 8 32 4 8 8 32 6 8 One Star ★ Two Star ★★ Three Star ★★★ 2 4 4 Maximum Optional Controller Types Supported Number of Devices per Poller Opto 22 input/output multiplexers 16 Steller input/output multiplexers 16 Recognition Systems Hand Geometry 16 Support Vicon CCTV Support (2) 1 Burle CCTV Support (2) 1 American Dynamics CCTV Support (2) 1 (2) Pacom CCTV Support 1 Radionics Receiver Support (2) 1 Photo ID bi-directional interface (3) 1 (2) Supports one type of CCTV interface per system (3) Photo ID Interface requires minimum of 450MB free space on Server hard drive Optional Terminal One Star ★ 16 16 16 16 16 16 1 1 1 1 1 1 1 1 1 1 1 1 Two Star ★★ Three Star ★★★ 7 5 11 5 Maximum Optional Terminals Supported 3 Operator Station (NexTerminal) for 3 Windows (4) (4) Each NexTerminal requires an additional 4MB memory at Server Printer Options One Star ★ Maximum # Report Printers Supported Maximum # Log Printers Supported • LaserJet Report Printer, 110V • Serial Log Printer, 110V 1 1 Two Star ★★ Three Star ★★★ 2 2 • LaserJet Report Printer, 220V • Serial Log Printer, 220V Notes: Peripheral devices (printers, terminals, modems, etc.) do not include cables. Replacement of memory chips may be required to configure for maximum memory. Additional memory may be required if utilizing system at maximum capacity (cardholders, access codes, on-line transactions, etc.) CONFIGURATION ADDENDUM 1 4 3 NEXSENTRY COMMAND CENTER SECURITY MANAGEMENT SYSTEM RC/RLC CONFIGURATION Standard Poller (R)LC/1 (1) Number of Pollers supported (R)LC/2 4 Remote Location Controllers (RLC) (R)LC/3 8 16 Number of Devices per Poller NexSentry/SE 800 Series/SE 422 16 Distributed Processing NexSentry/SE 800 Series/SE 422 Central 8 Processing Series SE 718P - Central Processing 8 (1) One ACU poller is included with each system. Please specify above. (R)LC/1 Optional Controller Support (2) Maximum optional controller types supported 16 16 8 8 8 8 (R)LC/2 4 (R)LC/3 4 4 Remote Dial-up Interface (RDI) Number of Devices per Poller Opto 22 input/output multiplexers 16 16 Steller input/output multiplexers 16 16 Recognition Systems Hand Geome try 1 1 support Vicon CCTV support (3) 1 1 Burle CCTV support (3) 1 1 American Dynamics CCTV support (3) 1 1 Pacom CCTV support (3) 1 1 Maximum optional controller types 4 4 supported Radionics receiver support 1 1 (2) If Controller Support is required on (R)LC, it must also be resident on the Server (3) Only one kind of CCTV support per system Optional Terminal (R)LC/1 (4) PC-Based color graphics terminal Monochrome text terminal (4) One optional terminal only allowed per LC Printer Options (R)LC/2 1 1 (R)LC/1 Maximum # report printers supported Maximum # log printers supported 0 1 16 16 1 1 1 1 1 4 1 1 1 1 1 (R)LC/3 0 2 SAMPLE SYSTEM CONFIGURATION DIAGRAM Server Report Printer S-Net 20 mA current loops S-Net RLC S-Net Operator Station S-Net Recommended access control system components 0 2 Readers: • DigiReader Series Digital Proximity Readers • DR 4200 and VIP-2 keypads • MSR 42 magnetic stripe reader and MSRK 42 magnetic stripe reader with integrated keypad • SE 2814/15 Analog Proximity Sensors • SE 2804 Compact Sensor Credentials: • NexKey low-cost proximity badge • QuadraKey multiple-technology card • DuraKey long-range proximity card • KeyMate proximity key fob • DuraTag RFID inventory control tag • SE 1050/60 analog proximity Command Key CCTV Camera Ethernet Ethernet Phone line Operator Station RDI units provide software and hardware support for up to three NexSentry or Alto 818SC controllers linked to a Server via modem. Controllers: • NexSentry 4100 Series Controllers • Alto 818SC Controller (R)LC/3 (R)LC/2 RLCs support the same functions as LCs but through periodic dial-up communication in which the server downloads information about cardholders, access privileges and alarm processing and uploads information about normal access and monitor point activity. RLCs will also call the server immediately when a user-defined alarm event occurs. CONFIGURATION ADDENDUM 2 Optional modules: • Photo ID: NexSentry Imaging Solutions • Elevator Control • CCTV Interface • Guard Tour Monitoring