Data Booklet - Grundfos Express Suite
Transcription
Data Booklet - Grundfos Express Suite
GRUNDFOS DATA BOOKLET PACO KP, KPV Split case pump 60 Hz PACO KP, KPV Table of contents 1. 2. 3. 4. 5. 6. Features and benefits 3 Nameplate 3 Applications 4 Commercial systems Industrial systems Water distribution Irrigation and aquaculture 4 4 4 4 Product range 5 Pump configurations 5 Performance range 6 KP 2-pole KP 4-pole KP 6-pole 6 7 8 Construction 9 KP pump, construction X2 KP pump, construction X4 KP pump, construction X5 and X7 KP pump, construction XK and XV KP pump, typical end view - Horizontal Std. components and material specification Mechanical construction 9 10 11 12 13 14 15 Operating conditions 18 Ambient temperature and altitude Liquid temperatures and shaft seals Shaft seal Pressure Flow KP Impeller Max Sphere Size KP model number and construction code 18 18 18 18 19 19 20 7. 8. 2 Curve charts and technical data 21 How to read the curve charts Curve conditions Performance tests Witness test KP 2095-1/2 [2-pole] KP 3095-7/8 [2-pole] KP 4012-1/2 [2-pole] KP 4012-7/8 [2-pole] KP 2095-1/2 [4-pole] KP 2013-5/6 [4-pole] KP 3095-7/8 [4-pole] KP 3014-7/8 [4-pole] KP 4012-1/2 [4-pole] KP 4012-7/8 [4-pole] KP 4015-9/0 [4-pole] KP 5012-7/8 [4-pole] KP 5015-9/0 [4-pole] KP 6012-3/4 [4-pole] KP 6015-3/4 [4-pole] KP 6019-7/8 [4-pole] KP 6020-3/4 [4-pole] KP 8012-5/6 [4-pole] KP 8015-3/4 [4-pole] KP 8020-5/6 [4-pole] KP 1012-1/2 [4-pole] KP 1015-3/4 [4-pole] KP 1020-3/4 [4-pole] KP 1024-3/4 [4-pole] KP 1415-1/2 [4-pole] KP 6019-7/8 [6-pole] KP 6020-3/4 [6-pole] KP 8015-3/4 [6-pole] KP 8020-5/6 [6-pole] KP 1012-1/2 [6-pole] KP 1015-3/4 [6-pole] KP 1020-3/4 [6-pole] KP 1024-3/4 [6-pole] KP 1220-5/6 [6-pole] KP 1415-1/2 [6-pole] 21 22 22 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 Bare shaft pump 58 1 PACO KP, KPV The double-suction design reduces axial forces by directing flow into both sides of the impeller. The double-volute design, available on most models, reduces the radial load and minimizes noise and vibration. Shaft sleeves are used to protect the shaft from corrosion and wear, thus extending the overall life of the shaft and the pump. Fig. 1 KP pump with motor and base Fig. 2 KP bare shaft pump with base, coupling, and guard Fig. 3 KP bare shaft pump TM05 5003 2712 Ease of service and long-term reliability are two of the selling features of the KP pumps. The split case design enables removal and dismantling of the internal pump parts (bearings, wear rings, impeller, and shaft seals) without disturbing the motor or pipe work. The twobearing design means less vibration and higher reliability. The separate bearing housings allow for inspection of the seals, sleeves and bearings without removing the top half of the casing. TM04 7331 1910 The Paco KP horizontal split case pump and KPV vertical split case pump are single stage, centrifugal volute pumps with high energy efficiency and low lifecycle costs. Features and benefits 1. Features and benefits KP pumps cover this performance range: Paco KP pumps are available in these different options: • Pump with motor and base (see fig. 1). • Bare shaft pump, i.e. pump without motor, with base (see fig. 2). • Bare shaft pump, i.e. pump without motor, without base (see fig. 3). • Or any combination requested by the customer Nameplate TM05 7638 1313 The pumps are non-self-priming, centrifugal volute pumps with radial suction and radial discharge ports and horizontal shaft. Impellers are hydraulically balanced. TM05 5875 3912 • Flow rate: 60 to 12000 gpm [10 to 2700 m3/h] • Head: 15 to 700 ft [5 to 215 m] • Motor (P2): 10 to 2000 hp KPV pumps • Same great features of KP, but in a vertical configuration for optimized space savings • Optional lower sleeve bearing design for easier lower bearing maintenance. 3 2 PACO KP, KPV Applications 2. Applications The Paco KP pumps are used in these main fields of application: • commercial systems • industrial systems • water distribution • irrigation. Liquid transfer and pressure boosting in: • air conditioning, primary and secondary chilled water systems • water condensing systems and cooling towers • boiler feed and condensate systems • district heating plants and heating systems • swimming pools • fountains. TM05 5977 4012 Commercial systems Fig. 4 KP pump used in commercial building applications Fig. 5 KP pump in sprinkler irrigation Industrial systems Water distribution Liquid transfer and pressure boosting in: • public waterworks • non-potable water systems. Irrigation and aquaculture Irrigation covers these applications: • field irrigation (flooding) • sprinkler irrigation • drip-feed irrigation • aqua farming. 4 GR 2910 Liquid transfer and pressure boosting in: • process cooling and chilled water systems • water condensing systems and cooling towers • boiler feed and condensate systems • industrial heating systems • wash down and cleaning systems • industrial processing systems (water, light chemicals, oils, etc). 3 PACO KP, KPV Product range 3. Product range Pump configurations Standard configuration Optional configuration Pump casing Cast Iron Ductile Iron Impeller Bronze • Cast Iron • Aluminium bronze • Stainless steel Sleeve Bronze Stainless steel Coupling • • Spacer Coupling Shaft seal Mechanical seal: Flange ANSI 125 ANSI 250 Flushing line None • Nylon • Copper • Stainless Steel Wear rings Bronze Stainless Steel Shaft Steel Stainless Steel Motor efficiency class NEMA Premium Others on request Pump direction of rotation CW - clockwise CCW - counter clockwise Elastomeric Grid Soft packing To a great extent the pumps can be adapted to the requirements of the individual customer. For customized solutions, contact your local Grundfos company. 5 4 PACO KP, KPV Performance range 4. Performance range Paco KP pumps are available with 2-, 4- or 6-pole motors. 8 and 10 pole are available on request. The next three pages show the performance range covered by these three motor types. Knowing your required duty point, use the performance ranges like this: 1. 2. 3. 4. Go into the relevant performance range chart. Find your duty point. Note which pump type covers your duty point. Go to section "Product range" and then to "Performance curves and technical data" and find more detailed information on your chosen pump. 6 90 100 70 60 23 TM05 5045 3812 80 25 100 30 120 40 150 50 200 60 70 80 300 90 500 400 100 H [m] H [ft] 100 30 150 40 200 50 250 300 2095-1/2 80 400 500 600 3095-7/8 800 200 1000 4012-1/2 300 Q [m³/h] 2000 1500 Q [US GPM] 4012-7/8 3550 rpm, 60 Hz KP KP 2-pole TM05 5978 3812 10 20 30 40 50 80 70 60 100 200 H [m] 15 20 25 40 50 60 80 100 150 200 250 400 500 600 800 H [ft] 23 100 30 150 40 2095-1/2 2013-5/6 50 60 70 80 200 250 300 4012-1/2 100 400 500 600 3095-7/8 3014-7/8 200 800 1000 4012-7/8 4015-9/0 5015-9/0 300 6015-3/4 6020-3/4 8015-3/4 400 500 600 6000 1012-1/2 1015-3/4 8020-5/6 800 1000 3000 4000 8012-5/6 6012-3/4 1500 2000 5012-7/8 6019-7/8 1024-3/4 KP 15000 KP 4-pole Performance range 2000 Q [m³/h] Q [US GPM] 10000 1415-1/2 1020-3/4 1780 rpm, 60 Hz PACO KP, KPV 4 7 8 10 12 15 20 30 40 50 60 80 100 120 150 200 300 TM05 5047 3812 4 5 8 7 6 10 20 30 40 50 80 70 60 100 400 H [ft] 100 400 500 600 200 800 6019-7/8 1000 1500 300 8015-3/4 400 500 2000 6020-3/4 1415-1/2 1020-3/4 5000 6000 1000 4000 600 700 800 2500 3000 1012-1/2 1015-3/4 8020-5/6 1024-3/4 2000 15000 Q [m³/h] Q [US GPM] 8000 10000 1220-5/6 1180 rpm, 60 Hz KP Performance range H [m] 4 PACO KP, KPV KP 6-pole 5 PACO KP, KPV Construction 5. Construction Paco KP horizontal split case pumps are available in several different construction types. KP pump, construction X2 All four construction types are available with packing as an option. TM03 9952 4707 Sectional view Fig. 6 Sectional view, construction X2, with mechanical shaft seals 9 5 PACO KP, KPV Construction KP pump, construction X4 Sectional view 66 20e 45 11 17 49 6a 109 114 53 113e 116b 113c 195 51 113d 11a 54 114a 79 124 116a 6b 24 TM05 7482 1013 105 Fig. 7 10 Sectional view, construction X4, with mechanical shaft seals 5 PACO KP, KPV Construction KP pump, construction X5 and X7 TM03 9954 4707 Sectional view Fig. 8 Sectional view, construction X5/X7, with mechanical shaft seals 11 5 PACO KP, KPV Construction KP pump, construction XK and XV TM03 9955 4707 Sectional view Fig. 9 12 Sectional view, construction XK/XV, with mechanical shaft seals 5 PACO KP, KPV Construction KP pump, typical end view - Horizontal TM04 1864 1108 (Non-drive end) Fig. 10 Typical end view (non-drive end) 13 5 PACO KP, KPV Construction Std. components and material specification Pos. no. Component ASTM standard ASTM A48 CL35 6a Pump casing, upper Cast Iron 6b Pump casing, lower Cast iron 11 Key, impeller Steel C1018, cold drawn steel 11a Key, coupling Steel C1018, cold drawn steel 17 Pipe plug Steel 20 Drain plug R 1/2 Steel 20a Plug, drain outlet Steel 20b Plug, inlet Steel 20c Plug, outlet Steel ASTM A48 CL35 20d Plug, shaft seal flushing Steel 20e Plug, suction chamber Steel 24 Locking pin, wear ring Steel ANSI/ASME B18.8 26b Roll pin Steel ANSI/ASME B18.8 26c Screw Steel 45 Wear ring Bronze ASTM B148, C95200 45b Wear ring with groove for retaining ring Bronze ASTM B148, C95200 49 Impeller Silicon bronze ASTM B584, C87600 51 Shaft Steel AISI 1144 Stress proof 53 Ball bearing, drive end Steel 54 Ball bearing, non-drive end Steel 54c Washer Steel 54d Retaining ring Carbon Spring Steel 58 Seal cover Grey Iron 58a Screw Steel 65 Retaining ring Stainless steel, series 303 66 O-ring NBR Impeller/shaft sleeve nut, right-hand thread Bronze Impeller/shaft lock nut, right-hand thread Stainless steel 67a Impeller/shaft sleeve nut, left-hand thread Bronze Impeller/shaft lock nut, left-hand thread Stainless steel 72a Gasket Vegetable fiber (HYD-401) 76 Nameplate Aluminum 79 Slinger Neoprene 105 Shaft seal 67b 14 Material SAE 1060-1090 lll932, C89835 lll932, C89835 109 O-ring NBR 109a O-ring NBR 110 O-ring NBR 113 Bearing housing Cast iron ASTM A48, CL30 113c Bearing cover, drive end Cast iron ASTM A48, CL30 113d Bearing cover, non-drive end Cast iron ASTM A48, CL30 113e Gasket Vegetable fiber 113f Lip seal, non-drive end bearing NBR 113g Lip seal, drive-end bearing NBR 114 Screw Steel 114a Screw Steel 114b Screw Steel 116 Shaft sleeve Bronze III932, C89835 116a Shaft sleeve, drive end Bronze I836 C89833 116b Shaft sleeve, non-drive end Bronze I836 C89833 116c Shaft sleeve, inner Bronze I836 C89833 116d Shaft sleeve, outer Bronze I836 C89833 116e Set screw Steel 124 Seal housing Cast iron 195 Lubricating nipple Zinc coated steel ASTM A48 CL30 5 PACO KP, KPV Mechanical construction Construction Bearings KP pumps are fitted with two standard single-row deep-groove ball bearings. The bearings are of the open type permitting the bearings to be relubricated. The bearings are lubricated by Grundfos prior to delivery. Pump casing The class 35 grey iron volute pump casing has radial suction port and radial discharge port. The pumps are of the inline (symmetric) design. TM04 0476 0708 Seal housings Fig. 11 Schematic drawing of an inline KP pump Flange Drillings are in accordance with ANSI #125 or #250. All KP pumps have two seal housings (pos. 124), one at the drive end and one at the non-drive end of the pump shaft. A seal housing has several functions: • Supports the pump sealing system, whether it is a mechanical shaft seal or packing • Supports the bearing housing thus transmitting both radial and axial forces from bearing and shaft to the upper and lower pump casing • Has a connection for the flushing pipe. The function of the flushing pipe is to ensure a flow of pumped liquid for cooling and lubricating the mechanical shaft seal or the packing Impeller TM03 3891 1106 TM04 0475 0708 The KP impeller (pos. 49) is a closed double-suction impeller. The impeller has inflow of liquid from both sides and is locked in position by a threaded sleeve arrangement. Fig. 12 Upper and lower pump casing of KP pump Shaft The shaft (pos. 51) is of the key and keyway type with one key for the impeller (pos. 11) and one key for the coupling (pos. 11a). The shaft is supported by bearings at both the drive end and the non-drive end of the pump. Fig. 14 Double-suction impeller All impellers are dynamically balanced in accordance with ANSI/ISO 1940 Class G6.3 standard. Due to their design, the impellers are inherently hydraulically balanced and thus compensate for axial thrust. All impellers are trimmed to the duty point required by the customer. TM04 0477 0708 Wear rings Fig. 13 KP pump shaft Shaft sleeves are attached to the pump shaft to prevent wear of the shaft and secure the position of the impeller. KP pumps have wear rings (pos. 45) between impeller and pump casing. As the name indicates, the wear rings protect the pump casing against wear. The wear rings act as a seal between impeller and pump casing. When the wear rings become worn, the efficiency of the pump will be reduced and the wear rings should be replaced. Coupling As standard, KP pumps are fitted with a flexible grid coupling or elastomeric coupling, depending or motor size. The grid coupling consists of two steel flanges horizontally split coupling halves. 15 5 PACO KP, KPV The packing rings consist of braided material which is effective for long service life for packing rings while protecting the shaft sleeve. TM04 1849 1108 TM04 0478 0708 Construction The coupling design assists in reducing vibrations and cushions shock loads. The design also extends the life of the coupling itself. The flexible grid is standard for VFD driven pumps. Fig. 15 Flexible grid coupling The elastomeric coupling has a flexible rubber section to absorb vibrations and minimizes negative affects of misalignment. Fig. 18 Sectional view of packing with internal flushing liquid Pos. TM05 5784 3812 1 Mechanical shaft seal The material of the standard version is Buna Carbon/ ceramic. Includes graphite impregnated packing rings. 16 Gland 3 Packing ring 4 Lantern ring A Drilled hole for flushing liquid (pumped liquid) Base Painting Prior to delivery to the customer, pump, motor and base are top coated with a blue paint (RAL 5015); coating thickness is 2 to 4 mils.The inside of the pump is primered for corrosion resistance. Standard units are not painted internally. TM04 0472 0708 Packing 2 Pump and motor are mounted on a common base frame designed according to Hydraulic Institute standard, ANSI/HI 1.3-2000. Fig. 16 elastomeric coupling Fig. 17 Rubber bellows shaft seal Description Shaft sleeve 5 PACO KP, KPV Construction Test pressure Pressure testing is made with water at ambient temperature. The standard hydrostatic test pressure is 1.5 times the flange rating pressure. KP Case working pressure limitations at 150 °F: Flat-face flanges Chart A Class 125 lb flange drilling (psi) Class 250 lb flange drilling (psi) CWP Hydro CWP Hydro 175 175 265 265 250 400 375 600 Cass material Cast iron Ductile iron All sizes except as Chart B indicates Chart B Maximum case working pressure (class 125 Flange) Pump model number 6019 6020 8020 Cast iron 1020 1024 1220 175 psi Ductile iron Maximum case working pressure (class 250 Flange) Pump model number 6019 6020 8020 1020 1024 1220 Cast iron 250 psi 250 psi 234 psi 222 psi 250 psi 211 psi Ductile iron 375 psi 375 psi 351 psi 333 psi 375 psi 317 psi CWP: maximum Case Working Pressure based upon flange drilling. Maximum working pressure for a given application is determined by adding the maximum available suction pressure to the shut-off head of a given impeller diameter. Hydro: Is the hydrostatic test pressure applied to the pump. Minimum hydrostatic test pressure is 1.5 times maximum allowable case working pressure. 17 6 PACO KP, KPV Operating conditions 6. Operating conditions Ambient temperature and altitude Carbon/Ceramic The ambient temperature and the installation altitude are important factors for the motor life, as they affect the life of the bearings and the insulation system. Ambient temperature must not exceed 104 °F [+ 40 °C]. If the ambient temperature exceeds 104 °F [+ 40 °C] or if the motor is installed more than 3280 ft [1000 m] above sea level, the motor must not be fully loaded due to the low density and consequently low cooling effect of the air. In such cases, it may be necessary to use a motor with a higher output, or use a motor that is designed for the specified ambient conditions. P2 [%] 110 100 90 80 70 60 20 25 30 35 40 45 50 55 60 65 70 T [°C] 70 80 90 100 110 120 130 140 150 160 T [°F] 3280 7382 11483 15584 [ft] TM00 2189 1598 50 Fig. 19 Relationship between motor output (P2) and ambient temperature Liquid temperatures and shaft seals The maximum liquid temperature marked on the pump nameplate depends on the mechanical shaft seal used: • Temperature range for Buna - standard): 32 °F to 212 °F [0 °C to +100 °C]. • Temperature range for Viton 54 °F to 212 °F [+15 °C to +100 °C]. • Temperature range for EPDM 54 °F to 275 °F [+15 °C to +135 °C]. Shaft seal The materials of the shaft seal types used in KP pumps have certain characteristics. These characteristics may be of importance when choosing the shaft seal for the pump. The seal has the following features: • Brittle material requiring careful handling. • Worn by liquids containing solid particles. • Limited corrosion resistance, 5 < pH < 9, depending on ceramic type. • The carbon of the seal offers properties very similar to the carbon/tungsten carbide seal. However, compared to the carbon/tungsten carbide seal, the pressure and temperature ranges are limited. Carbon/silicon carbide Seals with one carbon seal face have the following features: • Brittle material requiring careful handling • Worn by liquids containing solid particles • Good corrosion resistance • The self-lubricating properties of carbon make the seal suitable for use even with poor lubricating conditions (high temperatures) without generating noise. However, such conditions will cause wear of the carbon seal face leading to reduced seal life. Buna NBR (nitrile) rubber covers a wide range of liquids at temperatures below 212 °F [+100 °C]. • Good mechanical properties • Standard material Viton FKM rubber covers a very wide range of liquids and temperatures. • Poor mechanical properties at low temperatures • Resistant to water up to 275 °F [+135 °C] • Resistant to mineral oils and vegetable oils • Not resistant to alkaline liquids at high temperatures. EPDM EPDM Rubber covers a wider range of liquids up to a max temperature of 275 °F [135 °C]. • Good mechanical properties. Pressure Maximum inlet pressure Inlet pressure + pump pressure must always be lower than maximum pressure of the pump. Minimum inlet pressure The minimum inlet pressure must correspond to the NPSH curve for the pump. 18 6 PACO KP, KPV Operating conditions Flow Minimum flow rate The pump must not run against a closed discharge valve, as this will cause an increase in temperature/ formation of steam in the pump. This may cause shaft damage, impeller erosion, short life of bearings, stuffing boxes with packing rings or mechanical seals due to stress or vibration. The minimum, continuous flow rate must be at least 25% of the flow rate at best-efficiency point (BEP). KP Impeller Max Sphere Size Split Case Model Max Sphere Size [inches] 2095-1/2 0.19 2013-5/6 0.16 3095-7/8 0.31 3014-7/8 0.31 4012-1/2 0.38 4012-7/8 0.75 4015-9/0 0.25 5012-7/8 0.63 5015-9/0 0.75 6012-3/4 1.00 6015-3/4 0.81 6019-7/8 0.75 6020-3/4 0.75 8012-5/6 0.88 8015-3/4 1.00 8020-5/6 1.03 1012-1/2 1.00 1015-3/4 1.25 1020-3/4 1.20 1024-3/4 1.17 1220-5/6 1.87 1415-1/2 1.25 19 PACO KP, KPV KP model number and construction code Example 29 Materials of construction 60123 140001 1852 Product code Model code Materials of construction Motor code Production code 29 29: Split case Model code 60 12 3 Pump discharge 20 = 2" 30 = 3" 40 = 4" 50 = 5" 60 = 6" 80 = 8" 10 = 10" 12 = 12" 14 = 14" Nominal maximum impeller diameter 95 = 9.5" 12 = 12" 13 = 13" 14 = 14" 15 = 15" 19 = 19" 20 = 20" 24 = 24" Impeller design Clockwise rotation: 1, 3, 5, 7, 9 Counter clockwise rotation: 0, 2, 4, 6, 8 Materials of construction Packing or seal 3 = Standard Packing 1 = Type 21, Single Seal, Ceramic Seat, Buna 2 = Type 21, Single Seal, Tung Crbd Seat, Viton 6 = Type 21, Single Seal, Ni-Resist Seat, Viton 7 = Type 21, Single Seal, Ni-Resist Seat, Buna 8 = Type 1B, Single Seal, Ni-Resist Seat, Buna 9 = Type 21, Single Seal, Ni Resist Seat, Viton A = Type 1, Single Seal, Ceramic Seat, Buna B = Type 1, Single Seal, Ni-Resist Seat, Viton C = Type 1, Single Seal, Tung Cbrd Seat, Viton D = Type 1, Singel Seal, Ni Resist Seat, Buna E = Type 1, Single Seal, Ceramic Seat, Buna F = Type 1, Single Seal, Si Cbrd Seat, EPDM ID of packing or seal 2 = 1" 3 = 1-1/4" E = 1-1/2" 4 = 1-3/4" 5 = 2-1/4" 6 = 2-3/4" 7 = 3" K = 3-1/2" V = 4" General configuration (horizontal) Code no Item 00 Std. 01 Dbl- wear rings 02 Oil lube brgs 03 (01) + (02) 04 (01) + (05) 05 Recirc lines 20 Dbl Ext Shaft 21 Dbl Wear Rings 22 Recirc Lines 20 1 4 00 0 1 1 4 00 0 1 24 (21) + (22) 30 Dbl Ext Shaft 31 Dbl Wear Rings General configuration (horizontal) Code no Item 32 Recirc Lines 34 (31) + (32) 70 250 lb. Flange 71 Dbl Wear Rings 72 (71) + (73) 73 Recirc Lines 90 250 lb. Flange 91 Dbl Wear Rings General configuration (Vertical) Code no Item 50 Std 51 Dbl. Wear Rings 52 Sleeve Bearing 80 250 lb. flamge 81 Dbl. Wear Rings 82 Sleeve Bearing 92 250 lb. flamge 93 Dbl. Wear Rings Shaft/Sleeve Metallurgy 0 = Steel/Bronze 1 = Steel/S.S. 3 = S.S.l/Bronze* 6 = S.S./S.S. or S.S./no sleeves 7 = SS/Hard. SS A = 316 SS/Ni Al Bz X = Special Pump Metallurgy 1 = Brz. Fitted 2 = Std. All Bronze 5 = All Iron 8 = Ductile Iron/Brz. Fitted X = Special Motor code 1 Enclosure 1 = ODP 2 = TECF 3 = explosion proof Voltage 1 phase HP 115/230 V 1/3 21 1/2 29 3/4 35 1 41 1-1/2 47 2 53 3 59 5 65 7-1/2 71 10 76 15 -20 -25 -30 -40 -50 60 75 100 125 150 200 250 300 RPM 1 = 3500 2 = 1750 3 = 1150 ---------- 200 V 23 31 37 43 49 3 phase 230/460 V 24 32 38 44 50 55 61 67 73 77 56 62 68 74 78 81 84 01 02 03 04 05 06 07 ------ 82 85 87 88 89 90 91 92 93 94 95 96 97 98 78 2 7 PACO KP, KPV Curve charts and technical data 7. Curve charts and technical data How to read the curve charts Size of impeller d H [m] H [ft] /9.5 420 120 Total pump head H = Htotal KP 2095-1/2 60 Hz, n = 3550 rpm 400 380 110 /8.75 360 Pump type and speed 340 100 90 320 /8.125 300 QH curve for the individual pump. The bold curve indicates the recommended performance range. 280 80 /7.5 260 240 70 60 220 /6.75 200 180 40 160 140 NPSH [ft] [m] 120 30 20 10 100 100 80 80 60 60 40 40 NPSH 20 0 0 P2 [kW] 100 50 100 150 200 250 300 350 400 450 500 550 Eff [%] 140 70 120 60 /6.75 /7.5 /8.125 /8.75 /9.5 100 80 0 The eta curves show the efficiency of the pumps shown 40 60 30 /8.75 /8.125 40 20 0 50 /9.5 40 10 The NPSH curve is an average curve for all variants shown. Q [US GPM] P2 [hp] 80 60 20 20 0 0 30 20 /7.5 /6.75 20 10 0 0 0 0 50 100 20 150 200 250 40 60 300 350 80 400 The power curves indicate pump input power [P2] for the pumps shown 450 100 500 550 120 Q [US GPM] 140 Q [m³/h] TM05 5009 3212 50 Reference the Express Suite selection tool for selections in additional speeds. 21 7 PACO KP, KPV Curve charts and technical data Curve conditions Performance tests The guidelines below apply to the curves shown in the performance charts. • Tolerances according to: Hydraulic Institute. • The curves show pump performance with different impeller diameters at the nominal speed. • The bold part of the curves show the recommended operating range. • Do not operate the pump along the thin parts of the curves. If your duty point lies here, you should select a smaller or larger pump type. • Do not use the pumps at minimum flows below 0.1 x Qmax stated on the pump name plate because of the risk of overheating of the pump. • The curves apply to the pumping of airless water at a temperature of 77 °F [+20 °C] and a kinematic viscosity of 1 cSt [1 mm2/s]. • ETA: The lines show values of the hydraulic efficiency of the pump for the different impeller diameters. • NPSH: The curves show average values measured under the same conditions as the performance curves. When sizing the pump, add a safety margin of at least 1.6 ft [0.5 m]. • In case of other densities than 62.3 lb/ft3 [1000 kg/ m3] the discharge pressure is proportional to the density. • When pumping liquids with a specific gravity higher than 1.0, motors with correspondingly higher outputs must be used. Requested tests are performed according to Hydraulic Institute. Performance tests are only completed when ordered with the pump. Calculation of total head The total pump head consists of the height difference between the measuring points + the differential head + the dynamic head. H total 22 = H geo + Hstat + Hdyn Hgeo : Height difference between measuring points. Hstat : Differential head between suction and the discharge side of the pump. Hdyn : Calculated values based on the velocity of the pumped liquid on the suction and the discharge side of the pump. Witness test When the pumps are being tested it is possible for the customer to witness the testing procedure according to Hydraulic Institute. If the customer wants to witness the pump test this request must be submitted with the order. 7 PACO KP, KPV H [m] H [ft] /9.5 420 120 Curve charts and technical data KP 2095-1/2 [2-pole] KP 2095-1/2 60 Hz, n = 3550 rpm 400 380 110 /8.75 360 340 100 90 320 /8.125 300 280 80 /7.5 260 240 70 60 220 /6.75 200 180 50 40 160 140 NPSH [ft] [m] 120 30 20 10 100 100 80 80 60 60 40 40 NPSH 20 0 0 P2 [kW] 100 50 100 150 200 250 300 350 400 450 500 550 10 0 Q [US GPM] P2 [hp] Eff [%] 140 70 120 60 80 /6.75 /7.5 /8.125 /8.75 /9.5 100 60 20 20 0 0 30 50 80 40 /9.5 60 /8.125 40 20 0 30 /8.75 20 /7.5 /6.75 20 10 0 0 0 0 50 100 20 150 200 40 250 60 300 350 80 400 450 100 500 550 120 Q [US GPM] 140 Q [m³/h] TM05 5009 3212 40 23 7 PACO KP, KPV Curve charts and technical data KP 3095-7/8 [2-pole] H [m] H [ft] 420 120 KP 3095-7/8 /9.5 60 Hz, n = 3550 rpm 400 380 110 360 /8.75 340 100 90 320 300 /8 280 80 260 /7.25 240 70 220 60 200 /6.5 180 50 160 140 40 NPSH [ft] [m] 120 30 20 10 100 100 80 80 60 60 40 40 NPSH 20 0 0 P2 [kW] 100 100 200 300 400 500 20 10 20 0 0 30 600 700 800 900 1000Q 0 [US GPM] P2 [hp] Eff [%] 160 80 140 70 /8.75 120 80 100 /8 /7.25 /6.5 /9.5 /9.5 60 50 /8.75 60 80 40 /8 60 30 /7.25 40 20 0 20 10 0 0 0 0 24 20 /6.5 100 200 50 300 400 100 500 600 700 150 800 900 200 1000Q [US GPM] Q [m³/h] TM05 5010 3212 40 7 PACO KP, KPV H [m] H [ft] 440 130 120 Curve charts and technical data KP 4012-1/2 [2-pole] KP 4012-1/2 /10.3 420 60 Hz, n = 3550 rpm 400 380 110 360 /9.4 340 100 90 320 300 /8.4 280 80 260 240 70 60 /7.5 220 200 180 50 40 30 20 10 /6.5 160 NPSH [ft] [m] 140 120 120 100 100 80 80 60 60 40 40 NPSH 20 0 0 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 80 280 240 50 /10.3 160 120 /8.4 80 /6.5 40 30 /9.4 40 70 60 /7.5 /6.5 200 0 /10.3 /9.4 /8.4 160 40 0 Eff [%] 320 80 10 Q [US GPM] P2 P2 [kW] [hp] 120 20 20 0 200 30 20 /7.5 10 0 0 0 0 100 200 50 300 400 100 500 600 700 150 800 900 1000 1100 1200 1300 1400 200 250 300 Q [US GPM] Q [m³/h] 25 7 PACO KP, KPV Curve charts and technical data KP 4012-7/8 [2-pole] H [m] 120 H [ft] 400 KP 4012-7/8 /9.4 60 Hz, n = 3550 rpm 380 110 360 /8.8 340 100 90 320 300 /8.2 280 80 260 /7.6 240 70 220 60 /7.0 200 180 50 40 30 20 10 160 NPSH [ft] [m] 140 120 120 100 100 80 80 60 60 40 40 NPSH 20 0 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM] P2 P2 [kW] [hp] Eff [%] 400 80 350 70 /9.4 300 250 100 0 200 40 /7.6 /7.0 150 /9.4 /8.2 /7.0 50 /8.8 30 20 /7.6 10 0 0 0 0 26 50 /8.2 100 50 60 /8.8 200 150 20 10 20 0 250 30 200 400 100 600 800 200 1000 1200 1400 300 1600 1800 400 2000Q [US GPM] Q [m³/h] 0 7 PACO KP, KPV H [m] Curve charts and technical data KP 2095-1/2 [4-pole] H [ft] KP 2095-1/2 35 110 60 Hz, n = 1780 rpm /9.5 30 100 90 25 /8.75 80 /8.125 70 20 /7.5 60 15 /6.75 50 40 NPSH [ft] [m] 10 30 30 8 20 20 10 10 6 5 4 2 NPSH 0 0 0 P2 [kW] 10 20 40 60 80 100 120 140 160 180 200 220 240 260 P2 [hp] Eff [%] 14 70 12 60 8 /7.5 /6.75 /8.125 /8.75 10 6 4 /9.5 /9.5 8 /8.75 6 50 40 30 /8.125 4 20 /7.5 2 /6.75 2 0 0 Q [US GPM] 10 0 0 0 0 20 40 10 60 80 100 20 120 140 30 160 180 40 200 220 50 240 260 60 Q [US GPM] Q [m³/h] TM05 5013 3912 0 27 7 PACO KP, KPV Curve charts and technical data KP 2013-5/6 [4-pole] H [m] H [ft] KP 2013-5/6 60 60 Hz, n = 1780 rpm 200 /13 180 50 /12 160 140 /11 40 120 30 /10 100 /9 80 NPSH [ft] [m] 20 60 30 8 40 20 20 10 6 10 4 0 NPSH 0 0 0 P2 [kW] 2 40 80 120 160 200 240 280 320 360 0 Q [US GPM] P2 [hp] Eff [%] 60 60 40 50 /13 50 /12 30 40 /10 /11 40 /9 30 30 /13 20 /12 10 10 0 /9 /10 10 0 0 0 0 28 20 /11 40 80 20 120 160 200 40 240 280 60 320 360 80 Q [US GPM] Q [m³/h] TM05 5014 3912 20 7 PACO KP, KPV H [m] Curve charts and technical data KP 3095-7/8 [4-pole] H [ft] KP 3095-7/8 35 110 60 Hz, n = 1780 rpm /9.5 30 100 90 25 /8.75 80 /8 70 20 15 60 /7.25 50 /6.5 40 NPSH [ft] [m] 10 30 15 4 20 10 3 5 2 NPSH 10 5 1 0 0 0 P2 [kW] 20 50 100 150 200 250 300 350 400 450 500 Q P2 [hp] Eff [%] 32 80 28 70 /9.5 24 16 /6.5 /7.25 /8.75 /8 20 12 8 0 60 50 16 /9.5 /8.75 12 40 30 /8 8 4 0 [US GPM] 20 /7.25 /6.5 4 10 0 0 0 0 50 100 20 150 200 40 250 60 300 350 80 400 450 100 500 Q [US GPM] 120 Q [m³/h] TM05 5015 3912 0 29 7 PACO KP, KPV Curve charts and technical data KP 3014-7/8 [4-pole] H [m] H [ft] KP 3014-7/8 70 /14.0 220 60 60 Hz, n = 1780 rpm 200 /13.0 180 50 /12.0 160 140 /11.0 40 120 /10.0 30 100 80 NPSH [ft] [m] 20 60 60 40 40 15 10 10 20 20 NPSH 0 0 0 200 300 400 500 600 700 800 P2 [hp] Eff [%] 60 40 /12.0 /11.0 /10.0 /14.0 /13.0 /14.0 50 30 20 /13.0 40 60 40 /11.0 30 /10.0 10 10 20 0 10 0 0 30 70 50 /12.0 30 20 0 0 Q [US GPM] 100 200 50 300 400 500 100 600 700 150 800 Q [US GPM] 200 Q [m³/h] TM05 5016 3912 P2 [kW] 100 TM05 5016 3212 0 5 7 PACO KP, KPV H [m] H [ft] 40 130 Curve charts and technical data KP 4012-1/2 [4-pole] KP 4012-1/2 60 Hz, n = 1780 rpm /11.0 120 35 110 30 100 /9.9 90 25 80 /8.7 70 20 60 /7.6 15 50 NPSH [ft] [m] 40 10 40 /6.5 30 30 12 10 8 20 20 6 5 10 0 25 100 200 300 400 500 600 700 40 80 35 70 /8.7 /7.6 25 0 60 /11.0 /6.5 20 50 40 /9.9 15 30 /8.7 10 5 /11.0 /9.9 0 Q [US GPM] Eff [%] 30 10 900 P2 [hp] 20 15 800 20 /7.6 5 10 /6.5 0 0 0 0 100 200 50 300 400 500 100 600 700 150 800 900 200 Q [US GPM] Q [m³/h] TM05 5017 3912 P2 [kW] 2 0 0 4 TM05 5017 3212 0 10 NPSH 31 7 PACO KP, KPV Curve charts and technical data KP 4012-7/8 [4-pole] H [m] H [ft] KP 4012-7/8 /12.0 160 60 Hz, n = 1780 rpm 45 150 140 40 /10.8 130 120 35 110 30 /9.5 100 90 25 80 /8.3 70 20 60 /7.0 5 40 40 30 30 20 20 10 0 0 0 0 P2 [kW] 10 NPSH 100 200 300 400 500 600 700 800 900 1000 1100 P2 [hp] /12.0 70 /9.5 0 80 50 /12.0 40 40 /10.8 30 30 /9.5 20 /8.3 10 10 /7.0 0 0 0 0 32 2 60 /7.0 20 0 4 /8.3 50 10 6 70 /10.8 60 20 8 Eff [%] 40 30 10 Q [US GPM] 80 50 12 100 200 50 300 400 100 500 600 700 150 800 900 200 1000 1100 Q [US GPM] 250 Q [m³/h] TM05 5018 3912 10 NPSH [ft] [m] 50 TM05 5018 3212 15 7 PACO KP, KPV H [m] 90 H [ft] Curve charts and technical data KP 4015-9/0 [4-pole] KP 4015-9/0 300 60 Hz, n = 1780 rpm /15.25 280 80 260 /14.0 240 70 220 60 200 /12.5 180 50 160 /11.0 140 40 120 30 /9.5 100 NPSH [ft] [m] 80 20 60 60 40 40 20 20 15 10 10 NPSH 0 0 0 100 400 600 800 1000 1200 1400 P2 [hp] Eff [%] 160 80 140 /9.5 /11.0 /12.5 /14.0 120 /15.25 70 60 /15.25 80 100 60 40 50 /14.0 80 60 0 40 30 /12.5 40 20 0 Q [US GPM] 20 /11.0 /9.5 20 10 0 0 0 0 200 400 100 600 800 1000 200 1200 1400 300 Q [US GPM] Q [m³/h] TM05 5019 3912 P2 [kW] 200 TM05 5019 3212 0 5 33 7 PACO KP, KPV Curve charts and technical data KP 5012-7/8 [4-pole] H [m] H [ft] KP 5012-7/8 60 Hz, n = 1780 rpm 180 50 /12.0 160 140 /10.75 40 120 30 /9.5 100 NPSH [ft] [m] 80 40 /8.25 12 20 60 30 /7.0 8 40 20 20 10 10 4 NPSH 0 0 0 200 400 600 800 1000 1200 1400 1600 1800 P2 [kW] Q [US GPM] 90 80 80 /9.5 /12.0 /10.75 /9.5 60 70 60 /7.0 50 /12.0 40 50 40 /10.75 30 30 /9.5 20 /9.5 10 10 /7.0 0 0 0 0 200 400 100 600 800 1000 200 1200 1400 300 1600 1800 400 Q [US GPM] Q [m³/h] TM05 5020 3912 20 34 Eff [%] 90 70 0 TM05 5020 3212 0 7 PACO KP, KPV H [m] H [ft] KP 5015-9/0 280 80 Curve charts and technical data KP 5015-9/0 [4-pole] 60 Hz, n = 1780 rpm /15.0 260 240 70 220 /13.5 60 200 180 50 /12.0 160 140 40 /10.5 120 30 100 /9.0 NPSH [ft] [m] 80 20 60 60 40 40 15 10 10 20 0 0 0 0 P2 [kW] 20 NPSH 200 400 600 800 1000 1200 1400 1600 1800 2000 0 Q [US GPM] P2 [hp] Eff [%] 320 200 5 80 /12.0 280 /13.5 /15.0 /10.5 /9.0 240 70 60 160 200 120 30 /13.5 80 40 20 /12.0 40 /9.0 0 40 10 /10.5 0 0 0 0 200 400 100 600 800 200 1000 1200 1400 300 1600 1800 400 2000 Q [US GPM] 500 Q [m³/h] TM05 5021 3912 80 /15.0 160 TM05 5021 3212 120 50 35 7 PACO KP, KPV Curve charts and technical data KP 6012-3/4 [4-pole] H [m] H [ft] KP 6012-3/4 170 50 45 /12.0 60 Hz, n = 1780 rpm 160 150 140 40 /10.75 130 120 35 110 30 /9.5 100 90 25 /8.25 80 70 20 60 10 5 NPSH [ft] [m] 50 40 40 30 30 20 20 10 0 NPSH 0 0 0 P2 [kW] 200 10 400 800 1200 1600 2000 2400 2800 Eff [%] 280 90 240 160 /8.25 120 /9.5 2 0 60 50 /7.0 /12.0 40 /10.75 /9.5 40 30 /8.25 0 20 0 0 36 4 70 /10.75 /7.0 0 6 80 80 40 8 /12.0 200 80 10 Q [US GPM] P2 [hp] 160 120 12 400 800 200 1200 1600 2000 400 2400 2800 600 Q [US GPM] Q [m³/h] TM05 5023 3212 15 /7.0 7 PACO KP, KPV H [m] H [ft] 80 260 Curve charts and technical data KP 6015-3/4 [4-pole] KP 6015-3/4 60 Hz, n = 1780 rpm /15.0 240 70 220 /13.5 60 200 180 50 /12.0 160 140 40 /10.5 120 30 100 /9.0 80 20 NPSH [ft] [m] 60 60 40 40 15 10 10 20 0 0 0 P2 [kW] 200 400 800 1200 1600 2000 2400 2800 3200 3600 Eff [%] 320 90 280 80 /12.0 240 /13.5 /15.0 /10.5 /9.0 /15.0 200 80 160 0 70 60 50 /13.5 120 40 /12.0 80 40 0 Q [US GPM] P2 [hp] 160 120 5 30 /10.5 40 20 /9.0 0 10 0 0 400 800 200 1200 1600 400 2000 2400 2800 600 3200 3600 800 Q [US GPM] Q [m³/h] TM05 5024 3912 0 20 NPSH 37 7 PACO KP, KPV Curve charts and technical data KP 6019-7/8 [4-pole] H [m] H [ft] KP 6019-7/8 140 440 60 Hz, n = 1780 rpm /19.0 120 400 /18.0 360 /17.0 100 320 /16.0 280 80 /15.0 240 60 200 NPSH [ft] [m] 160 80 120 60 40 20 15 80 40 20 10 40 20 5 NPSH 0 0 0 0 400 800 1200 1600 2000 2400 2800 Q [US GPM] P2 P2 [kW] [hp] Eff [%] 400 250 80 350 /15.0 /16.0 /17.0 /18.0 300 250 100 0 200 50 40 /17.0 /16.0 150 30 /15.0 20 50 10 0 0 0 0 38 60 /18.0 100 50 70 /19.0 200 150 /19.0 400 800 200 1200 1600 2000 400 2400 2800 600 Q [US GPM] Q [m³/h] 0 7 PACO KP, KPV H [m] H [ft] KP 6020-3/4 /20.0 480 Curve charts and technical data KP 6020-3/4 [4-pole] 60 Hz, n = 1780 rpm 140 440 /18.5 120 400 360 100 /17.0 320 /15.5 280 80 240 60 /14.0 200 160 40 NPSH [ft] [m] 120 60 80 40 15 20 10 NPSH 40 0 0 0 500 800 1200 1600 2000 2400 2800 3200 3600 P2 [hp] Eff [%] 800 80 700 600 /14.0 400 /15.5 /17.0 /18.5 200 300 0 70 60 /18.5 400 50 40 30 /17.0 /15.5 200 100 /20.0 /20.0 500 300 0 Q [US GPM] 20 /14.0 100 10 0 0 0 0 400 800 200 1200 1600 400 2000 2400 2800 600 3200 3600 800 Q [US GPM] Q [m³/h] TM05 5026 3912 P2 [kW] 400 5 TM05 5026 3212 0 20 39 7 PACO KP, KPV Curve charts and technical data KP 8012-5/6 [4-pole] H [m] H [ft] KP 8012-5/6 170 50 45 /12.0 60 Hz, n = 1780 rpm 160 150 140 40 /10.8 130 120 35 110 /9.5 30 100 90 25 /8.25 80 70 20 60 15 10 5 /7.0 NPSH [ft] [m] 50 40 40 30 30 20 20 NPSH 10 0 10 0 0 0 P2 [kW] P2 [hp] 120 160 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM] 12 10 8 6 4 2 0 Eff [%] 90 80 /12.0 /10.8 140 /8.25 120 60 40 0 50 /10.8 80 40 60 30 /9.5 20 /8.25 /7.0 20 10 0 0 0 0 40 60 100 40 20 /12.0 /7.0 500 1000 200 1500 2000 400 2500 600 3000 3500 800 4000 Q [US GPM] 1000 Q [m³/h] TM05 5027 3912 80 70 /9.5 TM05 5027 3212 100 7 PACO KP, KPV H [m] H [ft] 80 260 Curve charts and technical data KP 8015-3/4 [4-pole] KP 8015-3/4 /15.0 60 Hz, n = 1780 rpm 240 70 220 /13.5 60 200 180 50 /12.0 160 140 40 /10.5 120 30 100 /9.0 80 20 NPSH [ft] [m] 60 60 40 40 15 10 10 20 0 0 0 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM] P2 [hp] 450 300 250 150 100 400 80 350 /13.5 /12.0 /10.5 0 /15.0 /15.0 /9.0 250 200 150 60 40 30 /12.0 20 /10.5 /9.0 50 70 50 /13.5 100 50 Eff [%] 90 300 200 0 10 0 0 0 0 500 1000 200 1500 2000 400 2500 600 3000 3500 800 4000 4500 1000 5000 1200 Q [US GPM] Q [m³/h] TM05 5028 3912 P2 [kW] 500 5 TM05 5028 3212 0 20 NPSH 41 7 PACO KP, KPV Curve charts and technical data KP 8020-5/6 [4-pole] H [m] H [ft] 440 130 120 60 Hz, n = 1780 rpm 400 380 110 KP 8020-5/6 /19.25 420 /17.94 360 340 100 90 320 /16.62 300 280 80 70 60 /15.31 260 240 /14.0 220 200 180 50 40 160 140 120 30 20 10 NPSH [ft] [m] 100 80 80 60 60 40 40 NPSH 20 0 0 0 P2 [kW] 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM] P2 [hp] 1800 1200 1000 600 15 10 20 5 0 0 Eff [%] 90 1600 1400 /14.0 1200 800 20 /16.62 /15.31 /17.94 /19.25 80 70 60 1000 50 800 40 /19.25 600 0 /14.0 200 20 10 0 0 0 0 42 /16.62 /15.31 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 200 400 600 800 1000 1200 1400 1600 Q [US GPM] Q [m³/h] TM05 5029 3912 400 200 30 /17.94 TM05 5029 3212 400 7 PACO KP, KPV H [m] H [ft] KP 1012-1/2 170 50 60 Hz, n = 1780 rpm /12.0 160 45 Curve charts and technical data KP 1012-1/2 [4-pole] 150 140 /11.07 40 130 120 35 /10.15 110 30 100 /9.23 90 25 80 /8.3 70 20 60 15 50 NPSH [ft] [m] 40 10 30 60 20 40 15 5 10 NPSH 10 0 0 0 P2 [kW] 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 20 5 0 0 Q [US GPM] P2 [hp] Eff [%] 360 90 240 320 80 200 280 /10.15 /9.23 240 /12.0 /11.07 70 60 160 200 120 50 /8.3 /12.0 160 40 /11.07 120 30 /10.15 80 40 0 20 /9.23 /8.3 40 10 0 0 0 0 500 1000 1500 200 2000 2500 400 600 3000 3500 4000 800 4500 5000 1000 5500 1200 6000 1400 Q [US GPM] Q [m³/h] TM05 5030 3912 80 43 7 PACO KP, KPV Curve charts and technical data KP 1015-3/4 [4-pole] H [m] H [ft] KP 1015-3/4 280 80 60 Hz, n = 1780 rpm /15.37 260 240 70 /14.18 220 60 200 /13.0 180 50 160 /12.0 140 /11.0 40 120 30 100 NPSH [ft] [m] 80 20 60 60 40 40 15 10 10 20 0 0 0 P2 [hp] Q [US GPM] 900 600 500 300 200 800 80 /14.18 700 /12.0 0 70 60 /11.0 500 50 /15.37 400 /14.18 300 /13.0 /11.0 100 40 30 20 /12.0 10 0 0 0 0 44 /15.37 /13.0 200 100 Eff [%] 90 600 400 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 200 400 600 800 1000 1200 1400 1600 Q [US GPM] Q [m³/h] TM05 5031 3912 P2 [kW] 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 5 TM05 5031 3212 0 20 NPSH 7 PACO KP, KPV H [m] H [ft] Curve charts and technical data KP 1020-3/4 [4-pole] KP 1020-3/4 480 60 Hz, n = 1780 rpm 140 /19.6 440 120 400 /18.25 360 100 /16.75 320 280 NPSH [ft] [m] /15.4 80 240 120 /14.0 60 40 35 200 100 30 160 80 25 120 60 80 40 20 15 20 10 NPSH 40 0 0 0 2000 3000 4000 5000 6000 7000 8000 9000 10000 P2 [hp] Eff [%] 1600 1000 90 1400 /15.4 1200 /16.75 /18.25 /19.6 800 600 0 60 50 /18.25 40 /16.75 /15.4 400 200 80 70 1000 400 /19.6 /14.0 800 600 0 Q [US GPM] 30 /14.0 200 20 0 10 0 0 1000 2000 500 3000 4000 5000 1000 6000 7000 1500 8000 9000 2000 10000 Q [US GPM] 2500 Q [m³/h] TM05 5032 3912 P2 [kW] 1000 5 TM05 5032 3212 0 20 45 7 PACO KP, KPV Curve charts and technical data KP 1024-3/4 [4-pole] H [m] H [ft] KP 1024-3/4 /24.8 750 60 Hz, n = 1780 rpm 220 700 200 180 650 /23.0 600 550 /21.0 160 500 140 450 /19.0 120 400 350 /17.0 100 300 200 80 150 60 100 40 40 20 0 15 10 NPSH 50 20 0 0 0 P2 [kW] 1000 2000 3000 4000 5000 6000 7000 8000 P2 [hp] Q [US GPM] 90 3200 80 2000 2800 /17.0 1200 800 0 /23.0 /21.0 /24.8 /24.8 1600 50 30 /21.0 20 /19.0 /17.0 400 70 40 /23.0 1200 10 0 0 0 0 1000 2000 500 3000 4000 5000 1000 6000 7000 1500 8000 0 60 2000 800 400 /19.0 5 Eff [%] 3600 2400 46 9000 10000 11000 2400 1600 20 9000 10000 11000 2000 2500 Q [US GPM] Q [m³/h] TM05 5033 3912 60 NPSH [ft] [m] 250 TM05 5033 3212 80 7 PACO KP, KPV H [m] H [ft] KP 1415-1/2 280 60 Hz, n = 1780 rpm /15.6 80 Curve charts and technical data KP 1415-1/2 [4-pole] 260 /14.75 240 70 220 /13.75 60 200 /13.0 180 50 /12.0 160 140 40 120 30 20 NPSH [ft] [m] 100 80 80 60 60 40 40 20 15 NPSH 10 10 20 0 0 0 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 P2 [hp] Q [US GPM] Eff [%] 900 90 600 800 80 500 700 /12.0 600 400 300 200 0 70 /14.75 /15.6 /13.0 /13.75 60 500 50 400 /15.6 /14.75 /13.75 300 200 100 0 /12.0 40 30 /13.0 20 100 10 0 0 0 0 1000 2000 3000 500 4000 5000 1000 6000 7000 8000 1500 9000 10000 11000 12000 2000 2500 Q [US GPM] 3000 Q [m³/h] TM05 5034 3912 P2 [kW] 1000 5 TM05 5034 3212 0 20 47 7 PACO KP, KPV Curve charts and technical data KP 6019-7/8 [6-pole] H [m] H [ft] 190 55 45 60 Hz, n = 1180 rpm 180 170 50 KP 6019-7/8 /19.0 /18.0 160 150 /17.0 140 40 /16.0 130 120 35 /15.0 110 30 100 90 25 20 80 70 60 15 10 5 NPSH [ft] [m] 50 40 40 30 30 20 20 10 0 0 0 0 P2 [kW] 100 10 NPSH 200 400 600 800 1000 1200 1400 1600 1800 10 8 6 4 2 0 Q [US GPM] P2 [hp] Eff [%] 160 80 140 12 /18.0 /15.0 /16.0 /17.0 /19.0 70 120 60 100 50 80 /18.0 60 0 20 /15.0 20 10 0 0 0 0 48 30 /17.0 /16.0 40 20 40 200 400 100 600 800 1000 200 1200 1400 300 1600 1800 400 Q [US GPM] Q [m³/h] TM05 5035 3912 40 /19.0 80 TM05 5035 3212 60 7 PACO KP, KPV H m] H [ft] KP 6020-3/4 70 220 60 Hz, n = 1180 rpm /20.0 60 200 /18.5 180 50 Curve charts and technical data KP 6020-3/4 [6-pole] 160 /17.0 140 40 /15.5 120 30 /14.0 100 80 NPSH [ft] [m] 20 60 30 8 40 20 10 NPSH 6 4 20 10 2 0 0 0 P2 kW] 00 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 P2 [hp] Eff [%] 320 80 280 240 /14.0 60 /15.5 /17.0 /18.5 /20.0 80 50 160 /20.0 120 /17.0 0 20 /15.5 /14.0 40 40 30 /18.5 80 40 70 60 200 20 0 Q [US GPM] 10 0 0 0 0 200 400 100 600 800 1000 200 1200 1400 1600 300 1800 2000 400 2200 500 2400 Q [US GPM] 600 Q [m³/h] TM05 5036 3212 TM05 5036 3912 0 49 7 PACO KP, KPV Curve charts and technical data KP 8015-3/4 [6-pole] H [m] H [ft] KP 8015-3/4 120 60 Hz, n = 1180 rpm 35 /15.0 110 30 100 /13.5 90 25 80 /12.0 70 20 60 15 /10.5 50 /9.0 40 10 NPSH [ft] [m] 20 30 6 15 4 20 10 5 0 0 0 400 800 1200 1600 2000 2400 2800 3200 3600 P2 [hp] Q [US GPM] 180 120 100 60 40 160 80 140 /10.5 /12.0 /15.0 /13.5 0 100 50 /15.0 80 /13.5 60 /12.0 20 40 30 20 /10.5 10 /9.0 0 0 0 0 50 70 60 /9.0 40 20 Eff [%] 90 120 80 0 400 800 200 1200 1600 400 2000 2400 2800 600 3200 3600 800 Q [US GPM] Q [m³/h] TM05 5037 3912 P2 [kW] 5 TM05 5037 3212 0 2 NPSH 10 7 PACO KP, KPV H [m] 60 H [ft] Curve charts and technical data KP 8020-5/6 [6-pole] KP 8020-5/6 60 Hz, n = 1180 rpm 200 /19.25 180 50 /17.94 160 140 /16.62 120 /15.31 100 /14.0 40 30 80 NPSH [ft] [m] 20 60 30 8 40 20 20 10 6 10 4 NPSH 0 0 0 250 800 1200 1600 2000 2400 2800 3200 3600 400 90 350 /16.62 /15.31 0 /19.25 80 70 60 /19.25 200 /17.94 150 /16.62 /15.31 100 50 /17.94 /14.0 250 0 Q [US GPM] Eff [%] 300 100 4400 P2 [hp] 200 150 4000 50 40 30 /14.0 50 20 0 10 0 0 400 800 200 1200 1600 400 2000 2400 2800 600 3200 3600 800 4000 4400 Q [US GPM] 1000 Q [m³/h] TM05 5038 3912 P2 [kW] 400 TM05 5038 3212 0 2 51 7 PACO KP, KPV Curve charts and technical data KP 1012-1/2 [6-pole] H [m] H [ft] KP 1012-1/2 75 22 20 18 60 Hz, n = 1180 rpm /12.0 70 65 /11.07 60 55 16 50 14 12 /10.15 45 /9.23 40 35 /8.3 10 NPSH [ft] [m] 30 8 25 25 20 20 15 15 7 6 4 6 5 4 10 10 NPSH 2 3 2 5 5 0 0 1 0 P2 [kW] 400 800 1200 1600 2000 2400 2800 3200 3600 Eff [%] 90 90 60 80 80 50 70 /10.15 20 0 /12.0 40 30 50 40 30 /10.15 20 /9.23 /8.3 10 70 60 /11.07 20 10 /12.0 /8.3 50 30 /11.07 /9.23 60 0 Q [US GPM] P2 [hp] 40 10 0 0 0 0 52 4000 400 800 200 1200 1600 400 2000 2400 2800 600 3200 3600 800 4000 Q [US GPM] 1000 Q [m³/h] TM05 5039 3912 0 7 PACO KP, KPV H [m] H [ft] Curve charts and technical data KP 1015-3/4 [6-pole] KP 1015-3/4 120 60 Hz, n = 1180 rpm /15.37 35 110 30 100 /14.0 90 25 80 /13.0 70 /12.0 60 /11.0 20 15 50 40 10 NPSH [ft] [m] 30 30 8 20 20 10 10 6 5 4 0 0 0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM] P2 [hp] 360 240 200 120 80 320 80 /14.0 280 /12.0 0 /15.37 /13.0 70 60 /11.0 200 50 160 40 /15.37 120 /14.0 80 40 Eff [%] 90 240 160 0 40 /11.0 /12.0 /13.0 30 20 10 0 0 0 0 400 800 200 1200 1600 400 2000 2400 2800 600 3200 3600 800 4000 4400 Q [US GPM] 1000 Q [m³/h] TM05 5040 3912 P2 [kW] 2 TM05 5040 3212 0 NPSH 53 7 PACO KP, KPV Curve charts and technical data KP 1020-3/4 [6-pole] H [m] 60 H [ft] KP 1020-3/4 60 Hz, n = 1180 rpm 200 /19.6 180 50 /18.25 160 140 /16.75 120 /15.4 100 /14.0 40 30 80 NPSH [ft] [m] 20 60 60 15 40 40 10 10 20 20 NPSH 0 0 0 0 P2 [kW] 250 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Eff [%] 400 90 /15.4 300 /18.25 /16.75 /19.6 /19.6 /14.0 200 0 Q [US GPM] P2 [hp] 350 5 250 80 70 60 /18.25 150 200 50 /16.75 150 /14.0 100 0 50 20 0 10 0 0 54 30 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 200 400 600 800 1000 1200 1400 1600 Q [US GPM] Q [m³/h] TM05 5041 3912 50 40 /15.4 TM05 5041 3212 100 7 PACO KP, KPV H [m] H [ft] KP 1024-3/4 /24.8 340 60 Hz, n = 1180 rpm 100 320 90 300 /23.0 280 80 Curve charts and technical data KP 1024-3/4 [6-pole] 260 240 /21.0 70 220 60 200 /19.0 180 50 160 /17.0 140 40 120 30 100 NPSH [ft] [m] 80 20 60 30 40 20 8 10 20 0 0 0 0 P2 [kW] 10 NPSH 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 Eff [%] 900 90 600 800 80 500 700 /17.0 600 /21.0 4 2 0 Q [US GPM] P2 [hp] /19.0 6 /24.8 /23.0 /24.8 70 60 400 500 200 400 300 0 30 /19.0 200 100 40 /21.0 20 /17.0 100 10 0 0 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 200 400 600 800 1000 1200 1400 1600 Q [US GPM] 1800 Q [m³/h] TM05 5042 3912 300 50 /23.0 55 7 PACO KP, KPV Curve charts and technical data KP 1220-5/6 [6-pole] H [m] H [ft] KP 1220-5/6 70 220 60 Hz, n = 1180 rpm /20.0 60 200 180 /18.25 50 160 /16.5 140 40 120 /14.75 30 100 /13.0 80 NPSH [ft] [m] 20 60 60 40 40 15 10 10 NPSH 20 0 0 0 P2 [kW] 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 P2 [hp] Eff [%] 900 90 800 80 500 700 70 600 /13.0 400 /16.5 /14.75 /20.0 /18.25 60 500 200 50 /20.0 400 /18.25 300 0 20 /14.75 100 10 /13.0 0 0 0 0 56 40 30 /16.5 200 100 0 Q [US GPM] 600 300 5 1000 2000 500 3000 4000 5000 1000 6000 7000 1500 8000 9000 10000 11000 2000 2500 Q [US GPM] Q [m³/h] TM05 5043 3912 0 20 7 PACO KP, KPV H [m] H [ft] KP 1415-1/2 /15.6 120 Curve charts and technical data KP 1415-1/2 [6-pole] 60 Hz, n = 1180 rpm 35 110 30 /14.75 100 /13.75 90 25 /13.0 80 /12.0 70 20 60 15 50 40 10 NPSH [ft] [m] 30 60 20 40 15 5 10 10 0 0 0 0 P2 [kW] 20 NPSH 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM] P2 [hp] 5 0 Eff [%] 200 90 180 80 140 /12.0 140 /13.0 70 /14.75 /15.6 /13.75 60 120 80 60 40 50 /15.6 100 40 /14.75 80 30 /13.75 /13.0 60 20 /12.0 40 20 10 20 0 0 0 1000 2000 500 3000 4000 1000 5000 6000 7000 1500 8000 Q [US GPM] 2000 Q [m³/h] TM05 5044 3912 100 160 TM05 5044 3212 120 57 8 PACO KP, KPV Bare shaft pump 8. Bare shaft pump Dimensional sketch TM04 1827 1108 DNs: Suction flange DNd: Discharge flange Dimensions All dimensions are in inches. Pump size 2095-1/2 2013-5/6 3095-7/8 3014-7/8 4012-1/2 4012-7/8 4015-9/0 5012-7/8 5015-9/0 6012-3/4 6015-3/4 6019-7/8 6020-3/4 8012-5/6 8015-3/4 8020-5/6 1012-1/2 1015-3/4 1020-3/4 1024-3/4 1220-5/6 1415-1/2 58 DNd 2 2 3 3 4 4 4 5 5 6 6 6 6 8 8 8 10 10 10 10 12 14 DNs 2-1/2 2-1/2 4 4 5 5 5 6 6 8 8 8 8 10 10 12 12 12 14 14 14 16 HZ 12-1/4 15-5/8 13 16-5/8 16-1/8 16-1/8 20 17-5/8 20-3/4 19-3/4 22-3/4 23-3/4 25-5/8 21-5/8 24-3/4 28-13/16 24-3/8 24-3/4 30-3/8 31-3/4 30-13/16 30-1/2 A 12 12 12 12 12 12 12 12 12 12 12-1/4 12 12-1/2 12 12-3/4 25-1/2 12-3/4 18 25-1/2 25-1/2 25-1/2 - AE 10-1/4 10-1/4 10-1/4 10-1/4 10-1/4 10-1/4 10-1/4 10-1/4 10-1/4 10-1/4 10-1/4 10-1/4 10-1/4 10-1/4 10-1/4 19-3/4 10-1/4 15 19-3/4 19-3/4 19-3/4 - D 7 8-1/2 8 10 10-1/8 10-1/8 13 14-1/2 16-1/8 16 18-1/4 17 17-3/4 17-1/4 19 20-13/16 19-13/16 20 23-1/16 25 25 - BP 7 7 7 9-1/4 9-1/4 9-1/4 12 10-1/4 10-1/4 10-1/4 16-1/2 12 12 14 17-1/2 16 17-1/2 12 16 16 16 - B 8-3/4 8-3/4 8-3/4 11 11-1/8 11-1/8 13-3/4 12 12 12 18 14 14 15-1/2 19-1/2 19-1/4 19-1/2 14 19-1/4 19-1/4 19-1/4 - DH/SH 3-1/2 3-1/2 4 5 4-7/8 4-7/8 6-1/4 6-1/2 6-1/2 6-1/2 7-1/4 6-3/4 6-3/4 6-3/4 7 7-13/16 8 10 9-11/16 12 12 - W 12 12 12 14-1/2 14-1/2 14-1/2 14-1/2 16-1/2 17 17 20 19-1/4 21-1/2 20 20-3/8 29-1/2 20-7/8 23-5/8 31-7/16 31-7/16 31-7/16 28-1/2 H 11-16 11/16 11/16 11/16 11/16 11/16 11/16 11/16 11/16 11/16 11/16 3/4 3/4 11/16 11/16 1-1/8 11/16 7/8 1-1/8 1-1/8 1-1/8 - 8 PACO KP, KPV Bare shaft pump Dimensional sketch TM04 1827 1108 DNs: Suction flange DNd: Discharge flange Dimensions All dimensions are in inches. Pump size 2095-1/2 2013-5/6 3095-7/8 3014-7/8 4012-1/2 4012-7/8 4015-9/0 5012-7/8 5015-9/0 6012-3/4 6015-3/4 6019-7/8 6020-3/4 8012-5/6 8015-3/4 8020-5/6 1012-1/2 1015-3/4 1020-3/4 1024-3/4 1220-5/6 1415-1/2 K(WxL) YY X 1/4x1/8 8-1/2 8-1/2 1/4x1/8 10 10 1/4x1/8 11 11 3/8x3/16 12 12 3/8x3/16 12 12 3/8x3/16 12 12 3/8x3/16 14-1/16 14-1/16 3/8x3/16 13 13 3/8x3/16 15 14 3/8x3/16 16 14 3/8x3/16 16 15 (X5)3/8x3/16 17 17 (X6)1/2x1/4 1/2x1/4 19 17 3/8x3/16 17 15 3/8x3/16 19 19 5/8x5/16 22 16-5/16 3/8x3/16 19-1/2 19-1/2 1/2x1/4 23 17 3/4x3/8 26 20 3/4x3/8 28 24 5/8x5/16 28 23 25-3/5 21-13/20 G 5/8 5/8 3/4 7/8 7/8 7/8 1 1 1 1 1-1/8 1 1 1-1/8 1-1/8 1-3/8 1-1/8 1-1/8 1-3/8 1-3/8 1-3/8 - U N 1 2-7/8 1 2-7/8 1 XE 1-3/16 2-7/8 1-1/2 2-3/4 1-1/2 2-3/4 1-1/2 2-3/4 1-1/2 2-3/4 1-1/2 2-3/8 1-1/2 2-3/8 1-1/2 2-3/8 1-3/4 3-11/16 (X5)1-3/4 (X5)3-11/16 (X6)2 (X6)3 2-1/8 3-16/16 1-3/4 3-11/16 1-3/4 3-11/16 2-1/2 4-1/4 1-3/4 3-11/16 2-1/4 6-1/8 3-1/8 6-7/8 3-1/8 9-5/16 2-1/2 4-1/4 2-1/2 - WS 8-1/2 8-1/2 8-1/2 9-7/8 9-7/8 9-7/8 8-1/2 11-3/8 11-7/8 11-7/8 11-3/4 13-1/4 15-1/2 13 11-5/8 21-1/2 12-1/8 17-5/8 23-3/8 23-3/8 21-1/2 - CP PACK SEAL 21-1/8 19-3/4 21-1/8 19-3/4 21-1/8 19-3/4 26-1/4 24-1/2 26-1/4 24-1/2 26-1/4 24-1/2 26-1/4 24-1/2 30-1/4 30-1/4 31-1/4 31-1/4 31-1/4 31-1/4 36-5/16 36-5/16 (X5)34-11/16 (X5)34-3/16 (X6)35-1/2 (X6)35-1/2 39-1/8 39-1/8 36-5/16 36-5/16 37-1/16 37-1/16 53-11/16 53-11/16 38-1/16 38-1/16 41-1/8 41-1/8 54-11/16 54-11/16 53-1/2 53-1/2 54-3/4 54-3/4 51-7/10 51-7/10 WB 16-3/8 16-3/8 16-3/8 20 20 20 21-3/8 22-1/2 23 23 29 26-1/4 28-1/2 27-3/4 30-1/8 39-1/8 30-5/8 30-5/8 41-5/16 41-5/16 39-1/8 - 59 © Copyright Grundfos Holding A/S ECM: 1109068 GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-3400 Telefax: +1-913-227-3500 GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Canada Phone: +1-905 829 9533 Telefax: +1-905 829 9512 Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto Apodaca, N.L. Mexico 66600 Phone: +52-81-8144 4000 Telefax: +52-81-8144 4010 The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. 98432075 0413
Similar documents
ASB Bearings: Cast Bronze - ID .125, OD .0375, Length .025
merican Sleeve Bearing (ASB) is a world-class manufacturer of sleeve bearings and bushings. We specialize in bronze and offer customer service that is unique. Our commitment to customer needs and a...
More information