Hardeeville Welcome Center Replacement
Transcription
Hardeeville Welcome Center Replacement
architecture ADDENDUM NUMBER: 1 PROJECT NAME: Hardeeville Welcome Center Replacement PROJECT NUMBER: P28-9742-PD (LAI PROJECT #14109) PREPARED BY: Liollio Architecture 147 Wappoo Creek Drive, Suite 400 Charleston, SC 29412 elissa@liollio.com DATE OF ISSUE: October 28, 2015 TO ALL BIDDERS OF RECORD: This Addendum modifies the Contract Documents only in the manner and to the extent stated herein and shown on any accompanying drawings and will become a part of the Contract Documents. Except as specified or otherwise indicated by this Addendum, all work shall be in accordance with the basic requirements of the Contract Documents. BIDDERS SHALL ACKNOWLEDGE RECEIPT OF ADDENDUM WHEN SUBMITTING BID. THIS ADDENDUM CONSIST OF 3 PAGE(S) AND THE FOLLOWING ENCLOSURES: I. ENCLOSURES: 1. Pre-Bid Conference Sign In Sheet (2 pages) 2. SE-330 Lump Sum Bid Form (6 pages) 3. Drawing Sheets as listed under Section IV. Changes to Drawings. (16 pages) II. GENERAL INFORMATION / CLARIFICATIONS: 1. Deadline for questions is November 2nd at 3pm. Questions must be submitted in writing to Jennifer Charzewski at jenniferc@liollio.com. 2. To be on the planholders list please send your Name, Company, mailing address, email contact, and phone number to Jennifer Charzewski at jenniferc@liollio.com. III. CHANGES TO SPECIFICATIONS: 1. SECTION 012300 ALTERNATES – add alternate #3: Provide VRF HVAC system in lieu of spit system fan coils for administration area as shown on documents IV. CHANGES TO DRAWINGS - Replace the drawing sheets previously issued with the sheets of the same name attached to this addendum. Civil Drawings: Hardeeville Welcome Center Replacement / 14109 Addendum 1 October 28, 2015 / Page 1 None Landscape Architecture Drawings None Structural Drawings: None Architectural Drawings: None Fire Protection Drawings: 1. Drawing FP-001: Replacement of Backflow Preventer Diagrams. 2. Drawing FP-100: Replacement of Backflow Preventer Note. Plumbing Drawings: 3. Drawing P-200: Replacement of Backflow Preventer Note. 4. Drawing P-400: Replacement of Incoming Water Service detail. Mechanical Drawings: 5. Drawing M-100: Redesign VRF HVAC system to split system fan coils. 6. Drawing M-100A: New drawing to show alternate for VRF HVAC system. 7. Drawing M-200: Redesign VRF HVAC piping system to split system fan coil piping systems. 8. Drawing M-200A: New drawing to show alternate for VRF HVAC piping system. 9. Drawing M-300: Renaming of FCU schematic to include alternate design. 10. Drawing M-301: Renaming of VRF system schematic for alternate design. 11. Drawing M-500: Schedule alterations Electrical Drawings: 12. Drawing E-100: Redesign electrical feeders to new base bid HVAC system. 13. Drawing E-100A: New sheet to show electrical feeders for alternate HVAC system. 14. Drawing E-501: Added note to make panel MDP main circuit breaker 100% rated. 15. Drawing E-601: Revised panel schedule to reflect base bid HVAC. Added note for changes to schedule if alternate is accepted. Added note to make panel MDP main circuit breaker 100% rated. 16. Drawing E-602: Revised panel schedule to reflect base bid HVAC. Added note for changes to schedule if alternate is accepted. V. QUESTIONS / ANSWERS: 1. Question: Sheet A701 Detail 1 – shows solid surface for the countertop and vanity base panel, the finish legend indicates PLAM 3 for the vanity base panel. Which is correct? Answer: The vanity base panel should be PLAM 3 as listed on A600. All countertops in 109, 111, 112, and 113 should be SS1 as listed on A600. 2. Question: Solid surface material for SF9 and SF10 – what is the material? Answer: Solid surface material for SF9 and SF10 to be SS1 on A600. Hardeeville Welcome Center Replacement / 14109 Addendum 1 October 28, 2015 / Page 2 3. Question: Lobby pieces Alternate 1 – are these to be made by millwork contractor or will they be purchased pieces by others? Answer: All pieces associated with Alternate 1 to be made by millwork contractor. 4. Question: Please advise whether the full height tile backsplash or solid surface backsplash. Detail 5/A712 states full tile backsplash, but detail 1/A701 looks like it might be solid surface. Answer: Detail 5/A712 is correct; the backsplash to be full height tile. 5. Question: Please specify which windows receive the roller shades. Answer: Please refer to sheet A600. The location is in the administration area. All windows in the administration area to receive roller shades; this includes Kitchen 119, Staff Work Room 116, and Manager Office 118. 6. Question: The allowance seems to be a lot lower than what some subs are bidding it based on the plans, I did not know how you wanted to go about pricing that section? Do I need to tell them we are just using the allowance or do we need to factor the allowance into their final price? Answer: We will be using the allowance only. The design team will work with the GC and landscape subcontractor to determine the extent of the landscape scope at time of installation. VI. SUBSTITUTION REQUESTS: Will be addressed in forthcoming addendum END OF ADDENDUM Hardeeville Welcome Center Replacement / 14109 Addendum 1 October 28, 2015 / Page 3 2015 Edition SE-330 LUMP SUM BID FORM Bidders shall submit bids on only Bid Form SE-330. BID SUBMITTED BY: (Bidder's Name) BID SUBMITTED TO: South Carolina Department of Parks, Recreation & Tourism (Owner’s Name) FOR: PROJECT NAME: Hardeeville Welcome Center Replacement PROJECT NUMBER: P28-9743-PD OFFER § 1. In response to the Invitation for Construction Services and in compliance with the Instructions to Bidders for the above-named Project, the undersigned Bidder proposes and agrees, if this Bid is accepted, to enter into a Contract with the Owner on the terms included in the Bidding Documents, and to perform all Work as specified or indicated in the Bidding Documents, for the prices and within the time frames indicated in this Bid and in accordance with the other terms and conditions of the Bidding Documents. § 2. Pursuant to Section 11-35-3030(1) of the SC Code of Laws, as amended, Bidder has submitted Bid Security as follows in the amount and form required by the Bidding Documents: Bid Bond with Power of Attorney Electronic Bid Bond Cashier's Check (Bidder check one) § 3. Bidder acknowledges the receipt of the following Addenda to the Bidding Documents and has incorporated the effects of said Addenda into this Bid: (Bidder, check all that apply. Note, there may be more boxes than actual addenda. Do not check boxes that do not apply) ADDENDA: § 4. #1 #2 #3 #4 #5 Bidder accepts all terms and conditions of the Invitation for Bids, including, without limitation, those dealing with the disposition of Bid Security. Bidder agrees that this Bid, including all Bid Alternates, if any, may not be revoked or withdrawn after the opening of bids, and shall remain open for acceptance for a period of 60 Days following the Bid Date, or for such longer period of time that Bidder may agree to in writing upon request of the Owner. § 5. Bidder herewith offers to provide all labor, materials, equipment, tools of trades and labor, accessories, appliances, warranties and guarantees, and to pay all royalties, fees, permits, licenses and applicable taxes necessary to complete the following items of construction work: § 6.1 BASE BID WORK (as indicated in the Bidding Documents and generally described as follows): Replacement of existing SCPRT Hardeeville Welcome Center and restroom facility along with associated sitework. $ , which sum is hereafter called the Base Bid. (Bidder - insert Base Bid Amount on line above) BF – 1 SE-330 2015 Edition SE-330 LUMP SUM BID FORM § 6.2 BID ALTERNATES as indicated in the Bidding Documents and generally described as follows: ALTERNATE # 1 (Brief Description): Millwork to include charging bar, four (4) kiosk stations, and brochure racks ADD TO or DEDUCT FROM BASE BID: $ (Bidder to Mark appropriate box to clearly indicate the price adjustment offered for each alternate) ALTERNATE # 2 (Brief Description): Modified Bitumen Built-Up Roof (Section 075520) in lieu of PVC Membrane Roof (Section 075419) for low-slope roof areas. ADD TO or DEDUCT FROM BASE BID: $ (Bidder to Mark appropriate box to clearly indicate the price adjustment offered for each alternate) ALTERNATE # 3 (Brief Description): Provide VRF HVAC system in lieu of spit system fan coils for administration area as shown on documents. ADD TO or DEDUCT FROM BASE BID: $ (Bidder to Mark appropriate box to clearly indicate the price adjustment offered for each alternate) § 6.3 UNIT PRICES: BIDDER offers for the Agency’s consideration and use, the following UNIT PRICES. The UNIT PRICES offered by BIDDER indicate the amount to be added to or deducted from the CONTRACT SUM for each item-unit combination. UNIT PRICES include all costs to the Agency, including those for materials, labor, equipment, tools of trades and labor, fees, taxes, insurance, bonding, overhead, profit, etc. The Agency reserves the right to include or not to include any of the following UNIT PRICES in the Contract and to negotiate the UNIT PRICES with BIDDER. No. 1. Unit of Measure ITEM Removal of unsuitable material / replacement DEDUCT $ $ 2. $ $ 3. $ $ 4. $ $ 5. $ $ 6. $ $ 7. $ $ 8. $ $ BF – 1A CY ADD SE-330 2015 Edition SE-330 LUMP SUM BID FORM § 7. LISTING OF PROPOSED SUBCONTRACTORS PURSUANT TO SECTION 3020(b)(i), CHAPTER 35, TITLE 11 OF THE SOUTH CAROLINA CODE OF LAWS, AS AMENDED (See Instructions on the following page BF-2A) Bidder shall use the below-listed Subcontractors in the performance of the Subcontractor Classification work listed: SUBCONTRACTOR CLASSIFICATION By License Classification and/or Subclassification (Completed by Owner) SUBCONTRACTOR'S PRIME CONTRACTOR'S NAME (Must be completed by Bidder) SUBCONTRACTOR'S PRIME CONTRACTOR'S SC LICENSE NUMBER (Requested, but not Required) BASE BID Air Conditioning - AC Electrical - EL Plumbing - PB ALTERNATE #1 ALTERNATE #2 ALTERNATE #3 . If a Bid Alternate is accepted, Subcontractors listed for the Bid Alternate shall be used for the work of both the Alternate and the Base Bid work. BF – 2 SE-330 2015 Edition SE-330 LUMP SUM BID FORM INSTRUCTIONS FOR SUBCONTRACTOR LISTING 1. 2. 3. 4. 5. 6. 7. 8. Section 7 of the Bid Form sets forth an Owner developed list of contractor/subcontractor specialties by contractor license category and/or subcategory for which bidder is required to identify the entity (subcontractor(s) and/or himself) Bidder will use to perform the work of each listed specialty.. a. Column A: The Owner fills out this column, which identifies the contractor/subcontractor specialties for which the bidder must list either a subcontractor or himself as the entity that will perform this work. Subcontractor specialties are identified by contractor license categories or subcategories listed in Title 40 of the South Carolina Code of laws. If the owner has not identified a specialty, the bidder does not list a subcontractor. b. Columns B and C: In these columns, the Bidder identifies the subcontractors it will use for the work of each specialty listed by the Owner in Column A. Bidder must identify only the subcontractor(s) who will perform the work and no others. Bidders should make sure that their identification of each subcontractor is clear and unambiguous. A listing that could be any number of different entities may be cause for rejection of the bid as nonresponsive. For example, a listing of M&M without more may be problematic if there are multiple different licensed contractors in South Carolina whose names start with M&M. Subcontractor Defined: For purposes of subcontractor listing, a subcontractor is an entity who will perform work or render service to the prime contractor to or about the construction site pursuant to a contract with the prime contractor. Bidder should not identify sub-subcontractors in the spaces provided on the bid form but only those entities with which bidder will contract directly. Likewise, do not identify material suppliers, manufacturers, and fabricators that will not perform physical work at the site of the project but will only supply materials or equipment to the bidder or proposed subcontractor(s). Subcontractor Qualifications: Bidder must only list subcontractors who possess a South Carolina Contractor’s license with the license classification and/or subclassification identified by the Owner in the first column on the left. The subcontractor license must also be within the appropriate license group for the work of the specialty. If Bidder lists a subcontractor who is not qualified to perform the work, the Bidder will be rejected as non-responsible. Use of Own forces: If under the terms of the Bidding Documents, Bidder is qualified to perform the work of a listed specialty and Bidder does not intend to subcontract such work but to use Bidder’s own employees to perform such work, the Bidder must insert its own name in the space provided for that specialty. Use of Multiple Subcontractors: a. If Bidder intends to use multiple subcontractors to perform the work of a single specialty listing, Bidder must insert the name of each subcontractor Bidder will use, preferably separating the name of each by the word “and”. If Bidder intends to use both his own employees to perform a part of the work of a single specialty listing and to use one or more subcontractors to perform the remaining work for that specialty listing, bidder must insert his own name and the name of each subcontractor, preferably separating the name of each with the word “and”. Bidder must use each entity listed for the work of a single specialty listing in the performance of that work. b. Optional Listing Prohibited: Bidder may not list multiple subcontractors for a specialty listing, in a form that provides the Bidder the option, after bid opening or award, to choose to use one or more but not all the listed subcontractors to perform the work for which they are listed. A listing, which on its face requires subsequent explanation to determine whether it is an optional listing, is non-responsive. If bidder intends to use multiple entities to perform the work for a single specialty listing, bidder must clearly set forth on the bid form such intent. Bidder may accomplish this by simply inserting the word “and” between the names of each entity listed for that specialty. Agency will reject as non-responsive a listing that contains the names of multiple subcontractors separated by a blank space, the word “or”, a virgule (that is a /), or any separator that the Agency may reasonably interpret as an optional listing. If Bidder is awarded the contract, bidder must, except with the approval of the Agency for good cause shown, use the listed entities to perform the work for which they are listed. If bidder is awarded the contract, bidder will not be allowed to substitute another entity as subcontractor in place of a subcontractor listed in Section 7 of the Bid except for one or more of the reasons allowed by the SC Code of Laws. Bidder’s failure to identify an entity (subcontractor or himself) to perform the work of a subcontractor specialty listed in the first column on the left will render the Bid non-responsive. BF – 2A SE-330 2015 Edition SE-330 LUMP SUM BID FORM § 8. LIST OF MANUFACTURERS, MATERIAL SUPPLIERS, AND SUBCONTRACTORS OTHER THAN SUBCONTRACTORS LISTED IN SECTION 7 ABOVE (FOR INFORMATION ONLY): Pursuant to instructions in the Invitation for Construction Services, if any, Bidder will provide to Owner upon the Owner’s request and within 24 hours of such request, a listing of manufacturers, material suppliers, and subcontractors, other than those listed in Section 7 above, that Bidder intends to use on the project. Bidder acknowledges and agrees that this list is provided for purposes of determining responsibility and not pursuant to the subcontractor listing requirements of SC Code Ann § 11-35-3020(b)(i). § 9. TIME OF CONTRACT PERFORMANCE AND LIQUIDATED DAMAGES a) CONTRACT TIME Bidder agrees that the Date of Commencement of the Work shall be established in a Notice to Proceed to be issued by the Owner. Bidder agrees to substantially complete the Work within 300 Calendar Days from the Date of Commencement, subject to adjustments as provided in the Contract Documents. b) LIQUIDATED DAMAGES Bidder further agrees that from the compensation to be paid, the Owner shall retain as Liquidated Damages the amount of $ 200.00 for each Calendar Day the actual construction time required to achieve Substantial Completion exceeds the specified or adjusted time for Substantial Completion as provided in the Contract Documents. This amount is intended by the parties as the predetermined measure of compensation for actual damages, not as a penalty for nonperformance. § 10. AGREEMENTS a) Bidder agrees that this bid is subject to the requirements of the laws of the State of South Carolina. b) Bidder agrees that at any time prior to the issuance of the Notice to Proceed for this Project, this Project may be canceled for the convenience of, and without cost to, the State. c) Bidder agrees that neither the State of South Carolina nor any of its agencies, employees or agents shall be responsible for any bid preparation costs, or any costs or charges of any type, should all bids be rejected or the Project canceled for any reason prior to the issuance of the Notice to Proceed. § 11. ELECTRONIC BID BOND By signing below, the Principal is affirming that the identified electronic bid bond has been executed and that the Principal and Surety are firmly bound unto the State of South Carolina under the terms and conditions of the AIA Document A310, Bid Bond, included in the Bidding Documents. ELECTRONIC BID BOND NUMBER: SIGNATURE AND TITLE: BF 3 SE-330 2015 Edition SE-330 LUMP SUM BID FORM CONTRACTOR'S CLASSIFICATIONS AND SUBCLASSIFICATIONS WITH LIMITATION SC Contractor's License Number(s): Classification(s) & Limits: Subclassification(s) & Limits: By signing this Bid, the person signing reaffirms all representation and certification made by both the person signing and the Bidder, including without limitation, those appearing in Article 2 of the Instructions to Bidders, is expressly incorporated by reference. BIDDER’S LEGAL NAME: ADDRESS: TELEPHONE: EMAIL: SIGNATURE: DATE: PRINT NAME: TITLE: BF 4 SE-330 FIRE PROTECTION GENERAL NOTES 1 FIRE PROTECTION SYMBOLS THE SPRINKLER CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL AND STRUCTURAL DRAWINGS, INCLUDING ALL REFLECTED CEILING PLANS PRIOR TO PREPARING THE BID. ATTENTION SHALL BE PAID TO STAIRWAYS, ELEVATOR HOIST WAYS, AREAS WITH FLOATING CEILINGS, LARGE EXPOSED DUCTWORK AND VERTICAL SLAB OPENINGS. 2 ALL LOW POINTS OF THE SPRINKLER SYSTEM SHALL BE PROVIDED WITH DRAINS PER NFPA-13 CURRENTLY ADOPTED REVISION. LOW POINT DRAINS SHALL BE CLEARLY MARKED AND PIPED TO THE EXTERIOR OF THE BUILDING. A VALVE DRAWING SHALL BE PROVIDED IN MECHANICAL ROOM SHOWING THE LOCATIONS OF ALL LOW POINT DRAINS. 3 ALL SPRINKLER HEAD TEMPERATURE RATINGS SHALL BE ORDINARY (165°F) UNLESS OTHERWISE INDICATED. ALL SPRINKLERS INSTALLED IN GYPSUM, PLASTER AND WOOD CEILINGS SHALL BE CONCEALED TYPE. ALL SPRINKLERS IN ACOUSTICAL CEILING TILE SHALL BE SEMI-RECESSED TYPE. FIRE SPRINKLER SYSTEM SPECIFICATION SHEET COMPONENTS AND SPECIALTIES 1 SYMBOL DESCRIPTION 2 C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. BACKFLOW PREVENTER (DOUBLE CHECK TYPE) 4 PIV FS ALL PIPE PENETRATIONS THROUGH MASONRY WALLS SHALL BE PROVIDED WITH THE MINIMUM CLEARANCE REQUIREMENTS FOR SEISMIC PROTECTION AS DEFINED BY NFPA 13. ALL PIPING LESS THAN FOUR (4) INCHES SHALL HAVE A PIPE SLEEVE A NOMINAL DIAMETER 2 IN. LARGER THAN THE NOMINAL DIAMETER OF THE PIPE. ALL PIPING FOUR (4) INCHES AND LARGER SHALL HAVE A PIPE SLEEVE A NOMINAL DIAMETER 4 IN. LARGER THAN THE NOMINAL DIAMETER OF THE PIPE. FIRE CAULK AND SLEEVE ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. REFER TO LIFE SAFETY PLANS FOR RATED ASSEMBLY LOCATIONS. 6 INSTALLATION OF INCOMING FIRE SERVICE SHALL BE IN ACCORDANCE WITH APPLICABLE WATER SYSTEM JURISDICTION REQUIREMENTS AND NFPA 24. FLOW SWITCH www.liollio.com 843.762.2222 843.762.2300 OUTSIDE STEM AND YOKE VALVE TS 5 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 POST INDICATING VALVE OUTSIDE STEM AND YOKE VALVE WITH TAMPER SWITCH RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 SPRINKLER HEAD SIDEWALL SPRINKLER HEAD FIRE DEPARTMENT SIAMESE CONNECTION (WALL MOUNTED) FIRE DEPARTMENT SIAMESE CONNECTION (FREE-STANDING) INDICATING TYPE ZONE/FLOOR CONTROL VALVE WITH TAMPER SWITCH FIRE PUMP TEST HEADER ALARM CHECK VALVE FIRE PUMP TEST HEADER (FREE-STANDING) WATER FLOW SWITCH T ST A DRY PIPE VALVE RMF ENGINEERING INC. CHARLESTON, SC C-00831 FS TO WET PIPE SYSTEM WATER MOTOR GONG RE SPR GI ST RS TS R IN A ALARM CHECK VALVE S O UT H C A OL ROOF TEST VALVE F EO E R E D E N G IN E E PIPING SYMBOLS SYMBOL DESCRIPTION DRY PIPE VALVE WATER FLOW ALARM BELL TS AIR COMPRESSOR FS SPR DSP F D SPR DRY SPRINKLER LINE FIRE LINE SPRINKLER DRAIN LINE SPRINKLER LINE Construction Documents TO DRY PIPE SYSTEM SECTIONAL DRAIN VALVE SIGHT GLASS Hardeeville Welcome Center Replacement UNION WITH CORROSION RESISTANT ORIFICE GIVING FLOW EQUIVALENT TO THE SMALLEST SPRINKLER ORIFICE IN THE SYSTEM FIRE SPRINKLER PIPING DRAIN RISER. EXTEND TO GRADE FIRE DEPARTMENT CONNECTION OSE Project Number: Project Number: FS Checked By: 1 Drawn By: 4" FIRE SERVICE Date: TS Revisions: 2 DRAIN TO DISCHARGE AT 18" AFG. TS Interstate 95, Jasper County, SC P28-9742-PD 14108 DWZ TJR 10/07/15 1 10/07/15 REBID 2 ADD1 10/28/2015 DOUBLE CHECK VALVE BACKFLOW PREVENTER ASSEMBLY FINISHED FLOOR F FIRE PROTECTION NOTES, SYMBOLS AND ABBREVIATIONS THRUST BLOCK PER NFPA FP-001 1 SCHEMATIC - FIRE PROTECTION RISER SCALE: N.T.S. DRAWING NOTES 5 6 4" FP MAIN SHALL BE ROUTED PERPENDICULAR TO ROOF PITCH ABOVE THE STRUCTURAL MEMBERS IN THE 6" DEPTH OF THE PURLINS. 2 3" FP MAIN SHALL PENETRATE THE LOW ROOF AND BE ROUTED 6" ABOVE THE LOW ROOF ON THE EXTERIOR OF THE BUILDING 4" FP -4'-0" INV. ELEV. REFER TO C401 FOR CONTINUATION PROVIDE AUTOMATIC DRY PIPE SPRINKLER SYSTEM PER NFPA 13 FOR OVER HANG 4" BACKFLOW PREVENTER IN RISE 1 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 2 www.liollio.com 843.762.2222 843.762.2300 FDC A RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 STAFF TOILET 121 MECHANICAL 116 STAFF STORAGE ROOM IT/ELEC 2" FP MAIN 117B 2 120 PROVIDE AUTOMATIC DRY PIPE SPRINKLER SYSTEM PER NFPA 13 FOR OVERHANG KITCHEN STAFF WORK ROOM 117A MANAGER OFFICE PLUMBING CHASE B 115 1 4" FP MAIN GI MEN A 114 PROVIDE AUTOMATIC WET SPRINKLER SYSTEM PER NFPA 13 MEN B R RMF ENGINEERING INC. CHARLESTON, SC C-00831 ST E R E D E N G IN E E Construction Documents 113 WELCOME CENTER 3" FP MAIN 100 S O UT H C A IN A ST A F EO OL T 118 RS 119 RE C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. 4 1 MECHANICAL ENCLOSURE 13 JAN. 112 FAMILY B VESTIBULE CUSTODIAL 111 101B 110 C WOMEN B 104 FAMILY A VENDING STORAGE 107 109 Hardeeville Welcome Center Replacement JAN. 106 PLUMBING CHASE VESTIBULE 105 102 OSE Project Number: Project Number: WOMEN A MOTHER'S ROOM 103 Checked By: 108 Drawn By: NIGHT LOBBY D 101 1 2 Date: Revisions: Interstate 95, Jasper County, SC P28-9742-PD 14108 DWZ TJR 10/07/15 1 10/07/15 REBID 2 ADD1 10/28/2015 3 FIRE PROTECTION COVERAGE PLAN 1 FIRE PROTECTION COVERAGE PLAN SCALE: 1/8" = 1'-0" FP-100 GRAPHIC SCALE 8 N 4 0 SCALE: 1/8" = 1'-0" UNIT OF MEASURE: FEET 8 16 GENERAL NOTES 1. REFER TO ISOMETRIC RISER DIAGRAMS FOR ADDITIONAL PIPE SIZES. 4 5 6 2. COORDINATE THE LOCATION OF ALL EQUIPMENT, PIPING AND DUCTWORK WITH ALL OTHERTRADES (PLUMBING, ELECTRICAL, ETC.) BEFORE INSTALLATION. C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. 3" CW, -4'-0" INV. ELEV. REFER TO C401 FOR CONTINUATION 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 2 3" BACKFLOW PREVENTER IN RISE NFHB 1 P-1B STAFF TOILET 1 1/2" CW 3/4" HWR IT/ELEC 116 3/4" HWR SHUT-OFF VALVE (TYP) DWH-01 1" CW 1" HW 3/4" HWR 1/2" HW 1" CW 120 3" CW SHUT-OFF VALVE (TYP) ROUTE 1" CW, 1" HW, 3/4" HWR PIPING BELOW GRADE DRAIN PAN RCP-01 RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 MECHANICAL 1 1/2" HW ET-01 1 843.762.2222 843.762.2300 A P-3A 121 1/2" CW www.liollio.com 1 P-1A P-1A P-1 P-1 P-1 P-1 P-2 P-2 P-2 P-2 STAFF WORK ROOM 119 117A ST A 118 1/2" CW LINE DN TO ICE-MAKER PLUMBING CHASE 115 P-2 1/2" CW 114 P-3 P-3 MEN B P-3 113 WELCOME CENTER GI 3/4" CW TO WATER FOUNTAIN, -4'-0" INV. ELEV. REFER TO C401 FOR CONTINUATION MEN A P-2 P-2 P-3 P-3 MECHANICAL ENCLOSURE 13 PROVIDE LOCKABLE HOSE BIBB UNDER SINK FOR MAINTENANCE PROVIDE LOCKABLE HOSE BIBB UNDER SINK FOR MAINTENANCE 112 P-1A FAMILY B 111 P-3A P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 PLUMBING CHASE 1" CW P-1 P-3 P-3 107 P-6 1" CW P-6 P-1 P-1 P-1 P-1 P-1 WOMEN A 103 P-1 VESTIBULE SHUT-OFF VALVE (TYP) CUSTODIAL 101B 110 P-1 P-1 P-1 P-3 P-3 P-3 2" CW 1" HW 3/4" HWR C 1" CW 1/2" HW 1" HW NFHB 1/2" CW NIGHT LOBBY 1/2" HW OSE Project Number: 101 1/2" CW Project Number: 1/2" CW Checked By: P-3 Drawn By: 108 D NFHB PROVIDE LOCKABLE HOSE BIBB UNDER SINK FOR MAINTENANCE 1 2 Hardeeville Welcome Center Replacement 1" CW MOTHER'S ROOM BALANCING VALVE (1.25 GPM) E VENDING STORAGE VESTIBULE P-1 E R E D E N G IN E 3/4" CW 102 P-1A ST 109 1/2" CW P-3A 1" CW 2" CW 105 106 P-4 P-3 P-1A FAMILY A RMF ENGINEERING INC. CHARLESTON, SC C-00831 P-4 JAN. WOMEN B JAN. R 2" CW 1 1/2" HW 3/4" HWR 1" CW 1" HW 1 104 S O UT H C A Construction Documents P-3 100 RE B P-2 NFHB 1" CW, 1" HW, 3/4" HWR DN IN WALL P-1A F EO IN A P-5 MANAGER OFFICE OL BALANCING VALVE (0.75 GPM) RS KITCHEN T NFHB Date: Revisions: Interstate 95, Jasper County, SC P28-9742-PD 14108 DWZ TJR 10/07/15 1 10/07/15 REBID 2 ADD1 10/28/2015 3 PLUMBING DOMESTIC WATER PIPING PLAN 1 PLUMBING DOMESTIC WATER - LEVEL 01 SCALE: 1/8" = 1'-0" P-200 GRAPHIC SCALE 8 N 4 0 SCALE: 1/8" = 1'-0" UNIT OF MEASURE: FEET 8 16 GRATE PRESSURE GAUGE WITH BALL VALVE FINISHED FLOOR VENT THROUGH ROOF 1 1/2" CW TO TRAP PRIMING CONNECTION FLASHING COLLAR 2 HOSE END DRAIN VALVE STAINLESS STEEL ADJUSTABLE CLAMPS SHUT-OFF VALVE PATE STEPPED POLYVINYL CHLORIDE BOOT CLAMPED TO BASE 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 VERTICAL BACKFLOW PREVENTER ASSEMBLY PATE SPUN ALUMINUM BASE SET IN MASTIC PIPE SLEEVE FLASHING COLLAR FINISHED FLOOR www.liollio.com 843.762.2222 843.762.2300 ROOF INSTALLATION RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 WATER SERVICE REFER TO FLOOR PLANS FOR SIZE OF DRAIN AND PIPING REFER TO RISER FOR PIPE SIZES SCALE: N.T.S. DETAIL - INCOMING WATER SERVICE (VERTICAL) SCALE: 12" = 1'-0" VIBRATION ISOLATORS GI WITH ROD STIFFENER AND STIFFENER PRESSURE GAUGE CLAMPS AS REQUIRED THERMOMETER WITH BALL VALVE E R E D E N G IN E E TEMPERING VALVE CONCENTRIC REDUCER SEISMIC CABLE BRACING SHUT-OFF VALVE 120°F CHECK VALVE STRAINER WITH PRESSURE/TEMPERATURE BLOWDOWN VALVE RELIEF VALVE PIPE THROUGH WALL SCHEDULE 40 ASTM A106 GRADE B GALVANIZED STEEL PIPE SLEEVE (SIZE AS REQUIRED TO ACCOMMODATE PIPE AND SEAL) SHUT-OFF VALVE MOTOR SUPPORT BRACKET SERVICE PIPE BALANCING VALVE WITH MEMORY STOP ELECTRIC WATER HEATER CHECK VALVE REFER TO PLANS FOR SIZE OF MAINS NOTES: Hardeeville Welcome Center Replacement CONCRETE FLOOR (REFER TO EXISTING DRAWINGS) FINISHED FLOOR RCP-01 LINKED WATERTIGHT SLEEVE ASSEMBLY WITH INSULATING NEOPRENE SEALS, END PRESSURE PLATES, AND STAINLESS STEEL TIGHTENING NUTS AND BOLTS (PROVIDE APPROPRIATE MATERIALS FOR SERVICE PIPE TEMPERATURES) 2"x1/2" THICK STEEL WATER STOP AND ANCHOR AROUND ENTIRE SLEEVE RCP-01 HOSE END DRAIN VALVE 3" FLOOR DRAIN HOSE END DRAIN VALVE PUMP SHALL BE INSTALLED HORIZONTAL OR VERTICAL AS REQUIRED BY THE PUMP MANUFACTURER. CRUSHED STONE (REFER TO EXISTING DRAWINGS) PROVIDE SEISMIC SWAY BRACING FOR ALL EQUIPMENT HANGERS PER THE INTERNATIONAL PACK REMAINING VOID WITH OAKUM AND CAULK OSE Project Number: Project Number: BUILDING CODE AND THE INTERNATIONAL MECHANICAL CODE. 4" CONCRETE PAD WITH 3. ST Construction Documents EXPANSION TANK OF PIPING WITH 3/8" DIAMETER RODS 2. RMF ENGINEERING INC. CHARLESTON, SC C-00831 FLEXIBLE CONNECTION SUPPORT PUMP AND MOTOR INDEPENDENT 1. R IN A SCALE: N.T.S. S O UT H C A OL 3 DETAIL - SANITARY VENT THROUGH ROOF F EO RS 2 T DETAIL - FLOOR DRAIN (TRAP PRIMER) ST A 1 REFER TO ARCHITECTURAL/ STRUCTURAL DRAWINGS FOR ROOF CONSTRUCTION RE C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. ROOF MEMBRANES CONTRACTOR SHALL VERIFY MAXIMUM LOADING ON EQUIPMENT SUPPORT ASSEMBLIES Checked By: UNION Drawn By: CHAMFERED EDGES Date: Revisions: 4 DETAIL - INLINE PUMP - SUSPENDED (RCP-01) SCALE: N.T.S. 5 DETAIL - ELECTRIC WATER HEATER (WITH RECIRC PUMP) SCALE: N.T.S. 6 DETAIL - PIPE PENETRATION THROUGH GRADE FLOOR Interstate 95, Jasper County, SC P28-9742-PD 14108 DWZ TJR 10/07/15 1 10/07/15 REBID 2 ADD1 10/28/2015 SCALE: N.T.S. PLUMBING DETAILS P-400 DRAWING NOTES 4 5 6 1 12" DIA. EXHAUST DUCT UP THROUGH ROOF. 2 BETWEEN EACH LINEAR SLOT DIFFUSER IN ROOM 100 PROVIDE FRAME TO MATCH THE LINEAR SLOTS. PAINT CENTER SECTION BLACK. REFER TO A702 AND A703 FOR ELEVATION DETAILS. BALANCE AND SET DAMPER TO 170 CFM. 2 3 4 5 6 6" DIA. EXHAUST DUCT UP THROUGH ROOF. 7 BETWEEN EACH LINEAR SLOT DIFFUSER IN ROOM 101 PROVIDE FRAME TO MATCH THE LINEAR SLOTS. PAINT CENTER SECTION BLACK. 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 2 843.762.2222 843.762.2300 A2 200 3 6"Ø 6"Ø 6 VAV-01 A2 200 12"x12" VD 1 EF-03 G3 1160 10"x8" 8"x8" 10"x10" VD 12"x10" T ST A 20"x10" E2 200 A1 100 10"x8" VAV-04 8"x6" K2 525 E3 250 VAV-05 12"x10" 8"x8" VD A2 8"x6" 150 VD VD A3 250 VD E4 410 12"x10" VD 12"x10" 10"x8" 12"x10" EF-05 1 VD 8"x8" 8"x8" E4 415 12"x10" E4 410 A3 240 VAV-02 A1 60 6 6"x6" VD 6"Ø 10"x10" 12"x10" VAV-08 VD VD 7 K1 200 6"x6" VD C3 100 10"x8" C VD Hardeeville Welcome Center Replacement VAV-03 10"x10" 16"x14" VAV-07 10"x8" 10"x8" VD OSE Project Number: A3 300 Project Number: Checked By: A1 80 Drawn By: 7 G1 310 2 E K1 210 K1 200 12"x12" E R E D E N G IN E 8"x8" VD 6"Ø A3 240 8"x6" C3 300 14"x12" 6"x6" EF-04 8"x8" A3 240 14"x12" 12"x12" 6 1 6"x6" A1 100 16"x14" EF-07 VD 10"x8" VD VD VD A1 60 EF-02 18"x16" 12"x10" A3 255 VD VD EF-06 6 K1 300 24"x18" E4 415 14"x12" 6 EF-08 6"Ø 18"x16" 12"x10" K2 525 12"x8" 20"x18" K2 525 ST VD 12"x10" G2 870 RMF ENGINEERING INC. CHARLESTON, SC C-00831 Construction Documents VD G1 585 VAV-06 K1 300 R A3 240 6 G2 870 4" HIGH CONCRETE PAD 2 K2 525 2 GI S O UT H C A VD 8"x8" (TYP) B ACCU-03 A3 240 VD A2 150 8" HIGH CONCRETE PAD RE KEF-01 KEH-01 F EO IN A C2 225 12"x8" G3 1165 8"x8" 6"Ø C1 60 10"x8" A2 200 RA MOD IN RISE OF DUCT VD 10"x8" VD VD 8"x6" E3 350 VD VD AHU-01 VD 8"Ø VD 12"x10" 2 20"x20" 8"x6" (TYP) C2 225 24"x24" 24"x24" 10"x10" 12"x10" VD 10"x10" OA DUCT UP TO INTAKE AIR HOOD VD C1 150 8"x8" 12"x12" 16"Ø E3 300 VD FCU-02 14"x12" 10"x10" RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 FCU-03 VD A2 200 A1 40 A RS FCU-01 EF-01 26"x24" ACCU-01 24"x18" ACCU-02 www.liollio.com FLEXIBLE DUCT CONNECTION (TYP) 6" HIGH CONCRETE PAD OL C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. SA MOD IN RISE OF DUCT G1 315 D G1 310 Date: Revisions: Interstate 95, Jasper County, SC P28-9742-PD 14108 Checker Author 10/07/15 2 ADD1 10/28/2015 3 MECHANICAL DUCTWORK LEVEL 1 1 MECHANICAL DUCTWORK - LEVEL 01 SCALE: 1/8" = 1'-0" M-100 GRAPHIC SCALE 8 N 4 0 SCALE: 1/8" = 1'-0" UNIT OF MEASURE: FEET 8 16 4 5 6 DRAWING NOTES SA MOD IN RISE OF DUCT C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. WORK IN THIS AREA IS ASSOCIATED WITH ALTERNATE FLEXIBLE DUCT CONNECTION (TYP) WORK IN THIS AREA IS ASSOCIATED WITH ALTERNATE 1 12" DIA. EXHAUST DUCT UP THROUGH ROOF. 2 3 BETWEEN EACH LINEAR SLOT DIFFUSER IN ROOM 100 PROVIDE FRAME TO MATCH THE LINEAR SLOTS. PAINT CENTER SECTION BLACK. REFER TO A702 AND A703 FOR ELEVATION DETAILS. BALANCE AND SET DAMPER TO 110 CFM. 4 BALANCE AND SET DAMPER TO 50 CFM. 5 BALANCE AND SET DAMPER TO 40 CFM. 6 6" DIA. EXHAUST DUCT UP THROUGH ROOF. 7 BETWEEN EACH LINEAR SLOT DIFFUSER IN ROOM 101 PROVIDE FRAME TO MATCH THE LINEAR SLOTS. PAINT CENTER SECTION BLACK. 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 www.liollio.com VD VAV-04 8"x6" C3 60 K2 525 A3 240 VD A2 150 B VAV-05 12"x10" ACCU-01 114 8"x8" 6" HIGH CONCRETE PAD 8"x8" RE WORK IN THIS AREA IS ASSOCIATED WITH ALTERNATE MEN A WELCOME CENTER F EO S O UT H C A R IN A 4 C3 225 8" HIGH CONCRETE PAD RMF ENGINEERING INC. CHARLESTON, SC C-00831 GI ST RS 118 E3 250 10"x8" OL VD E2 200 A1 100 MANAGER OFFICE KEF-01 KEH-01 26"x24" 20"x10" 5 8"x8" 12"x8" G3 1165 FCU-04 FCU-02 VD 12"x10" 8"x8" 8"x8" 3 RA MOD IN RISE OF DUCT T A2 200 E3 350 ST A VD 12"x10" 2 VD VD 10"x8" VD VD FCU-01 VD 8"x8" (TYP) AHU-01 VD VD C3 225 8"x8" VD 10"x10" 10"x10" OA DUCT UP TO INTAKE AIR HOOD 1 EF-03 G3 1160 8"x8" RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 VD 6"x6" 12"x10" 24"x24" 24"x24" E3 300 VD 12"x10" C3 150 12"x12" 16"Ø VD FCU-03 VD VD 843.762.2222 843.762.2300 FCU-05 116 VAV-01 20"x20" A1 40 A2 200 A2 200 24"x18" 6 A MECHANICAL VD 6"Ø A2 200 8"x8" VD EF-01 E R E D E N G IN E E K2 525 A2 8"x6" 150 VD 100 VD 6 12"x10" VD A3 250 VD E4 410 12"x10" A3 255 10"x8" 12"x10" EF-05 A1 60 VD 8"x8" 8"x8" 12"x10" A3 240 E4 410 WOMEN A VAV-02 A1 60 6"x6" VD 6"Ø 10"x10" 12"x10" VAV-08 14"x12" C3 300 7 K1 200 VD VD 6"x6" EF-04 8"x8" A3 240 12"x12" 6"Ø A1 80 6 C 10"x10" 109 10"x8" 10"x8" VD A3 300 101 OSE Project Number: 7 G1 310 G1 315 Project Number: D Checked By: G1 310 Drawn By: Date: 3 Revisions: Interstate 95, Jasper County, SC P28-9742-PD 14108 DWZ TJR 10/07/15 2 ADD1 10/28/2015 MECHANICAL DUCTWORK - LEVEL 01 (ALTERNATE) 1 SCALE: 1/8" = 1'-0" AIR COOLED CONDENSER SCHEDULE (ALTERNATE) COOLING CAPACITY (MBH) 67.1 OUTDOOR FAN NO MOTOR 2 ELECTRICAL FLA 33.9 (V/PH/HZ) 208/1/60 MCA 49 ELECTRIC DUCT HEATER SCHEDULE (ALTERNATE) OUTDOOR DESIGN TEMP (°F DB) MOCP 50 SUMMER 96 WINTER 27 COMPRESSOR NO 2 REFRIGERANT R-410A WEIGHT LBS. 695 BASIS OF DESIGN MITSUBISHI REMARKS DESIGNATION EDH-01 EDH-02 EDH-04 SERVICE FCU-01 FCU-02 FCU-04 MBH 12.1 5.2 2.2 NUMBER OF ELEMENTS 1 1 1 KW 3.5 1.5 1.0 ELECTRICAL 208/3/60 208/3/60 208/3/60 FAN COIL UNIT SCHEDULE (ALTERNATE) FAN EAT °F DESIG FCU-01 FCU-02 FCU-03 FCU-04 FCU-05 Hardeeville Welcome Center Replacement VENDING STORAGE VAV-03 VD 108 DESIG ACCU-01 110 16"x14" VAV-07 MOTHER'S ROOM 2 CUSTODIAL VD K1 210 NIGHT LOBBY A3 240 6"x6" 10"x8" 8"x8" K1 200 14"x12" 12"x12" 103 1 6"x6" 8"x6" 16"x14" EF-07 VD 1 VD VD 10"x8" E4 415 12"x10" 111 EF-02 18"x16" VD 6 A1 100 6"Ø 6 VD VD 107 EF-06 FAMILY B 6 K1 300 24"x18" E4 415 14"x12" K2 525 12"x10" WOMEN B VD 104 18"x16" 12"x10" FAMILY A K2 525 20"x18" G1 585 G2 870 VD G2 870 VD 2 12"x8" EF-08 C3 100 VD (TYP) VAV-06 K1 300 Construction Documents A3 240 MAX CFM 560 240 720 100 830 OA CFM 110 50 40 MCA 2.1 1.8 4.3 1.8 4.3 REFRIGERANT R-410A R-410A R-410A DB 79.1 80.2 75.0 83.3 75.0 WB 65.9 66.6 62.0 69.0 62.0 COIL DUTY COOLING CAPACITY SENSIBLE (MBH) TOTAL (MBH) 21.7 15.7 8.3 5.9 15.0 14.7 5.1 3.3 17.0 17.0 HEATING CAPACITY TOTAL (MBH) 9.1 3.9 11.7 1.6 13.4 MOUNTING CEILING SUSPENDED CEILING SUSPENDED WALL MOUNTED CEILING SUSPENDED WALL MOUNTED ELECTRICAL (V/PH/HZ) 208/1/60 208/1/60 208/1/60 208/1/60 208/1/60 BASIS OF DESIGN MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI BASIS OF DESIGN GREENHECK GREENHECK GREENHECK 2 REMARKS 1,2 1,2 1,2 MECHANICAL DUCTWORK LEVEL 1 (ALTERNATE) REMARKS M-100A GRAPHIC SCALE 8 N 4 0 SCALE: 1/8" = 1'-0" UNIT OF MEASURE: FEET 8 16 DRAWING NOTES 4 5 6 1 MAIN BRANCH CIRCUIT CONTROLLER MOUNTED HIGH IN MECHANICAL ROOM REFRIGERANT PIPING DISTRIBUTED THROUGHOUT THE BUILDING FROM THESE LOCATIONS. 2 REFRIGERANT LIQUID AND SUCTION LINES. ONLY ONE IS SHOWN FOR CLARITY, TWO ARE REQUIRED (TYP). 3 PROVIDE WATER TIGHT WALL PENETRATION. 4 3/4" CD TO DISCHARGE AT 0'-8" AFF TO SPLASH BLOCK AT GRADE. PROVIDE WATER TIGHT WALL PENETRATION. 5 MOUNT REFRIGERANT LIQUID AND SUCTIONS LINES TO WALL ON UNISTRUT. 6 DEEP SEAL P-TRAP AT CONDENSATE DRAIN. 7 1" CD TO DISCHARGE AT 0'-8" AFF TO SPLASH BLOCK AT GRADE. PROVIDE WATER TIGHT WALL PENETRATION. C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. 2 2 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 www.liollio.com 2 843.762.2222 843.762.2300 ACCU-02 ACCU-01 2 5 7 4 6 2 4 3 A 3/4" RL VAV-01 FCU-03 FCU-01 FCU-02 T 6 6 RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 FCU-03 FCU-02 T AHU-01 6 GI AD-1 E T VAV-06 VAV-01 VAV-02 T C T VAV-06 VAV-03 T E R E D E N G IN E VAV-05 T VAV-08 ST Construction Documents PIPE SUPPORT VAV-04 RE B ACCU-03 RMF ENGINEERING INC. CHARLESTON, SC C-00831 RS T ST A VAV-05 T R IN A 2 5 VAV-04 FCU-01 S O UT H C A OL 2" CD F EO Hardeeville Welcome Center Replacement T VAV-02 VAV-08 VAV-03 VAV-07 VAV-07 OSE Project Number: T Project Number: Checked By: Drawn By: D 1 2 Date: Revisions: Interstate 95, Jasper County, SC P28-9742-PD 14108 Checker Author 10/07/15 2 ADD1 10/28/2015 3 MECHANICAL PIPING PLAN LEVEL 01 1 MECHANICAL PIPING PLAN - LEVEL 01 SCALE: 1/8" = 1'-0" M-200 GRAPHIC SCALE 8 N 4 0 SCALE: 1/8" = 1'-0" UNIT OF MEASURE: FEET 8 16 DRAWING NOTES C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. 4 5 6 WORK IN THIS AREA IS ASSOCIATED WITH ALTERNATE 1 MAIN BRANCH CIRCUIT CONTROLLER MOUNTED HIGH IN MECHANICAL ROOM REFRIGERANT PIPING DISTRIBUTED THROUGHOUT THE BUILDING FROM THESE LOCATIONS. 2 REFRIGERANT LIQUID AND SUCTION LINES. ONLY ONE IS SHOWN FOR CLARITY, TWO ARE REQUIRED (TYP). 3 PROVIDE WATER TIGHT WALL PENETRATION. 4 3/4" CD TO DISCHARGE AT 0'-8" AFF TO SPLASH BLOCK AT GRADE. PROVIDE WATER TIGHT WALL PENETRATION. 5 1 1/2" CD TO DISCHARGE AT 0'-8" AFF TO SPLASH BLOCK AT GRADE. PROVIDE WATER TIGHT WALL PENETRATION. 6 MOUNT REFRIGERANT LIQUID AND SUCTIONS LINES TO WALL ON UNISTRUT. 7 DEEP SEAL P-TRAP AT AHU-01 CONDENSATE DRAIN. 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 www.liollio.com 843.762.2222 843.762.2300 4 A STAFF TOILET 1 121 4 VAV-01 MECHANICAL BC-01 FCU-02 3 T IT/ELEC FCU-03 120 FCU-05 116 FCU-03 RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 FCU-05 T AHU-01 T 7 ROUTE REFRIGERANT PIPING BELOW GRADE FCU-01 1" CD 3/4" CD FCU-04 FCU-01 1 1/2" CD FCU-02 MANAGER OFFICE VAV-04 T ST A 2 6 VAV-05 118 T ACCU-01 GI 114 RMF ENGINEERING INC. CHARLESTON, SC C-00831 ST E R E D E N G IN E Construction Documents PIPE SUPPORT AD-1 VAV-04 VAV-05 T T 111 VAV-02 Hardeeville Welcome Center Replacement VAV-06 CUSTODIAL FAMILY B VAV-01 E 115 PLUMBING CHASE RE B MEN A R IN A T FCU-04 S O UT H C A OL 2" CD F EO RS 5 110 T C T VAV-06 FAMILY A VAV-03 107 VAV-08 T VAV-02 T PLUMBING CHASE VAV-08 105 VENDING STORAGE VAV-03 109 VAV-07 MOTHER'S ROOM VAV-07 T 108 OSE Project Number: NIGHT LOBBY Project Number: 101 WOMEN A Checked By: 103 Drawn By: Date: D 1 2 Revisions: Interstate 95, Jasper County, SC P28-9742-PD 14108 DWZ TJR 10/07/15 2 ADD1 10/28/2015 3 2 MECHANICAL PIPING PLAN PIPING PLAN (ALTERNATE) 1 MECHANICAL PIPING PLAN - LEVEL 01 (ALTERNATE) SCALE: 1/8" = 1'-0" M-200A GRAPHIC SCALE 8 N 4 0 SCALE: 1/8" = 1'-0" UNIT OF MEASURE: FEET 8 16 SEQUENCE OF OPERATION: 3. EXHAUST FAN SHALL HAVE MOTOR OPERATED DAMPER WHICH IS PROVEN OPEN BY AN END SWITCH PRIOR TO STARTING FAN. WHEN EXHAUST FAN IS DE-ENERGIZED, THE DAMPER SHALL CLOSE GRADUALLY TO ALLOW FOR FAN WIND-DOWN TIME. THE FAN SHALL BE MANUALLY INDEXED ON BY THE ROOM OCCUPANCY SENSOR. 2. EXHAUST FAN SHALL HAVE MOTOR OPERATED DAMPER WHICH IS PROVEN OPEN BY AN END SWITCH PRIOR TO STARTING FAN. WHEN EXHAUST FAN IS DE-ENERGIZED, THE DAMPER SHALL CLOSE GRADUALLY TO ALLOW FOR FAN WIND-DOWN TIME. 3. A LOSS OF FLOW WHILE THE FAN IS ENERGIZED OR FAILURE OF THE FAN TO START AS SENSED BY THE FAN MOTOR CURRENT SENSING RELAY SHALL DE-ENERGIZE THE FAN AND ALARM THE BAS. EF BI 3 1. A LOSS OF FLOW WHILE THE FAN IS ENERGIZED OR FAILURE OF THE FAN TO START AS SENSED BY THE FAN MOTOR CURRENT SENSING RELAY SHALL DE-ENERGIZE THE FAN AND ALARM THE BAS. EF BI 3 RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 ES EXHAUST FAN EXHAUST FAN EF B0 2 MOD M www.liollio.com 843.762.2222 843.762.2300 ES EF B0 2 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 MOD EF AI 1 CT EF BI 1 CT EF BI 1 BMS CONNECTION EF AI 1 O OCCUPANCY SENSOR 2 SCALE: N.T.S. ST A SCHEMATIC - EXHAUST FAN (EF-02, 03, 07, 08) SCHEMATIC - EXHAUST FAN (EF-01, 04, 05, 06) SCALE: N.T.S. GI S O UT H C A R IN A 1 F EO OL T O M RE C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. 2. SEQUENCE OF OPERATION: THE FAN SHALL BE CONTROLLED BY THE BMS OCCUPIED/UNOCCUPIED SCHEDULE. WHEN THE BUILDING IS OCCUPIED, THE FAN SHALL RUN CONTINUOUSLY. RMF ENGINEERING INC. CHARLESTON, SC C-00831 ST RS 1. E R E D E N G IN E E Construction Documents SEQUENCE OF OPERATION: A. SYSTEM CONTROL 1. THE INDOOR FAN COIL UNIT SHALL BE CONTROLLED TO MAINTAIN THE OCCUPIED AND UNOCCUPIED INDOOR SPACE TEMPERATURE SETPOINTS. THE FAN COIL UNIT SUPPLY FAN SHALL RUN CONTINUOUSLY AND THE OA-MOD SHALL BE OPEN WHEN THE UNIT IS ENERGIZED. THE UNIT REFRIGERANT CIRCUIT SHALL CYCLE ON/OFF BASED ON THE INDOOR HEATING/COOLING REQUIREMENTS. SEQUENCE OF OPERATION: 2. A FAILURE OF THE FAN COIL UNIT SUPPLY FAN, AS SERVED BY ITS CURRENT SENSING RELAY SHALL BE ALARMED TO THE SYSTEM CONTROLLER. UPON SEEING FAILURE, THE SYSTEM CONTROLLER SHALL INDICATE ALARM, DISABLE THE UNIT AND RETURN ALL CONTROLS TO THEIR NORMAL POSITION. 3. WHEN THE FCU IS IN OCCUPIED MODE AND THE SPACE RELATIVE HUMIDITY IS ABOVE SET POINT(50% RH ADJ.), THE FCU WILL BE IN HUMIDITY MODE. THE FAN WILL RUN AT A HUMIDITY MODE PRESET SPEED. THIS SHALL BE ADJUSTED TO OBTAIN NEUTRAL AIR TEMPERATURE 75 °F.THE REFRIGERANT CIRCUIT WILL MODULATE TO MAINTAIN A HUMIDITY MODE SUPPLY AIR TEMPERATURE SET POINT (55 °F ADJ.). THE ELECTRIC HEATER STAGES WILL CYCLE TO MAINTAIN THE SPACE SPACE TEMPERATURE SETPOINT. WHEN THE RETURN AIR RELATIVE HUMIDITY DROPS BELOW THE SETPOINT MINUS THE DIFFERENTIAL (5% ADJ.), FCU WILL RETURN TO NORMAL COOLING OR HEATING MODE. 4. 5. Hardeeville Welcome Center Replacement A. PROVIDE A FLOAT SWITCH IN THE CONDENSATE DRAIN PAN TO SHUT DOWN THE UNIT WHEN WATER IS PRESENT. UPON ACTIVATION OF FLOAT SWITCH THE BAS SHALL INDICATE ALARM, DISABLE THE UNIT AND RETURN ALL CONTROLS TO THEIR NORMAL POSITION. SYSTEM CONTROL 1. THE INDOOR FAN COIL UNIT SHALL BE CONTROLLED TO MAINTAIN THE OCCUPIED AND UNOCCUPIED INDOOR SPACE TEMPERATURE SETPOINTS. THE FAN COIL UNIT SUPPLY FAN SHALL RUN CONTINUOUSLY AND THE OA-MOD SHALL BE OPEN WHEN THE UNIT IS ENERGIZED. THE UNIT REFRIGERANT CIRCUIT SHALL CYCLE ON/OFF BASED ON THE INDOOR HEATING/COOLING REQUIREMENTS. 2. A FAILURE OF THE FAN COIL UNIT SUPPLY FAN, AS SERVED BY ITS CURRENT SENSING RELAY SHALL BE ALARMED TO THE SYSTEM CONTROLLER. UPON SEEING FAILURE, THE SYSTEM CONTROLLER SHALL INDICATE ALARM, DISABLE THE UNIT AND RETURN ALL CONTROLS TO THEIR NORMAL POSITION. 3. UPON THE DETECTION OF PRODUCTS OF COMBUSTION SHUT DOWN THE FCU AND SEND AN ALARM TO THE BAS. PROVIDE A FLOAT SWITCH IN THE CONDENSATE DRAIN PAN TO SHUT DOWN THE UNIT WHEN WATER IS PRESENT. UPON ACTIVATION OF FLOAT SWITCH THE BAS SHALL INDICATE ALARM, DISABLE THE UNIT AND RETURN ALL CONTROLS TO THEIR NORMAL POSITION. OSE Project Number: Project Number: 4. UPON THE DETECTION OF PRODUCTS OF COMBUSTION SHUT DOWN THE FCU AND SEND AN ALARM TO THE BAS. Checked By: OUTDOOR AIR FCU B0 2 Drawn By: Date: ES FCU BI 1 OA-MOD VOLUME DAMPER DX COIL FCU AI 3 FCU AI 5 FILTER ELECTRIC REHEAT COIL Revisions: DX COIL RETURN AIR FCU AI 3 TS-1 FILTER Interstate 95, Jasper County, SC P28-9742-PD 14108 DWZ TJR 10/07/15 2 ADD1 10/28/2015 FCU AI 5 TS-2 RETURN AIR DPT CT RS M MECHANICAL SCHEMATICS TS-1 TS-2 RL FCU BI 4 DPT 2 3 SCHEMATIC - FAN COIL UNIT (FCU-01, AND ALTERNATE FCU-01, 02, 04) SCALE: N.T.S. FCU AI 1 T TEMPERATURE SENSOR FCU AI 6 H HUMIDITY SENSOR CT RS M RL FCU BI 4 2 4 FCU AI 1 T TEMPERATURE SENSOR SCHEMATIC - FAN COIL UNIT (FCU-02, 03, AND ALTERNATE FCU-03, 05) SCALE: N.T.S. M-300 GENERAL NOTES: 1. ENERGY RECOVERY HEAT PUMP SHALL BE CAPABLE OF PROVIDING SIMULTANEOUS HEATING AND COOLING TO EACH FAN COIL UNIT. ACCU-01 1/4:1/2 REFRIGERANT YFITTING 1/4:1/2 1/4:1/2 1/4:1/2 1/4:1/2 FCU-01 117 T 119 T 120 T 118 T 116 T FCU-02 FCU-03 FCU-04 FCU-05 RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 F EO 2 1 SCHEMATIC - VRF SYSTEM (ALTERNATE) R IN A GI S O UT H C A OL 4. SCHEMATIC SHOWS TYPICAL PIPE SIZES AND COMPONENTS REQUIRED FOR INSTALLATION OF THE BASIS OF DESIGN HEAT PUMP SYSTEM (MITSUBISHI). REFRIGERANT PIPING SHALL BE SIZED IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS BASED ON THE PROJECT SPECIFIC LAYOUT AND LENGTH OF REFRIGERANT PIPING. PRIOR APPROVED MANUFACTURERS SHALL, PRIOR TO BID, PROVIDE A PROJECT SPECIFIC SCHEMATIC SHOWING ALL INFORMATION REQUIRED TO PRICE THE INSTALLATION OF THEIR HEAT PUMP SYSTEM. SCHEMATIC SHALL INCLUDE PIPE LENGTHS, PIPE SIZES, BRANCH/CIRCUIT CONTROLLERS, SPECIALTY PIPE FITTINGS/BRANCHES, ELECTRICAL LOADS AND CONTROLS. ANY SYSTEM COMPONENTS OR ELECTRICAL CHANGES REQUIRED TO INSTALL A HEAT PUMP SYSTEM OTHER THAN THE BASIS OF DESIGN SHALL BE INCLUDED IN THE PROJECT BID. INSTALLATION AND DESIGN OF ANY SYSTEM OTHER THAN THE BASIS OF DESIGN SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND, AFTER PROJECT AWARD, BE OF NO ADDITIONAL COST TO THE OWNER. 843.762.2222 843.762.2300 RMF ENGINEERING INC. CHARLESTON, SC C-00831 ST RS BC-01 www.liollio.com T 3/8:3/4:5/8 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 ST A BRANCH CONTROLLER 3/8:7/8:3/4 3. THE VARIABLE CAPACITY, HEAT PUMP HEAT RECOVERY AIR CONDITIONING SYSTEM SHALL BE CONNECTED TO THE NEW BUILDING CONTROL AUTOMATION SYSTEM AT THE CENTRALIZED CONTROLLER. ALL SETPOINTS AND PROGRAMS MUST BE ABLE TO BE MONITORED BY THE CONTROLS USER INTERFACE. THE BAS SHALL NOT BE USED TO CONTROL THE HEAT PUMP SYSTEM. ALL CONTROLS FOR THE HEAT PUMP SYSTEM SHALL BE PERFORMED BY THE INTEGRAL FACTORY CONTROL SYSTEM. FACTORY CONTROL SYSTEM SHALL BE ENABLED TO BE CONTROLLED THROUGH THE INTERNET FROM A REMOTE LOCATION. CONTROL ACCESS SHALL BE PROVIDED FOR A MINIMUM OF FIVE SIMULTANEOUS USERS. RE C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. 2. EACH FAN COIL UNIT SHALL BE PROVIDED WITH AN ISOLATION VALVE ON THE REFRIGERANT PIPING. E R E D E N G IN E E Construction Documents SCALE: N.T.S. Hardeeville Welcome Center Replacement OSE Project Number: Project Number: Checked By: Drawn By: Date: Revisions: Interstate 95, Jasper County, SC P28-9742-PD 14108 DWZ TJR 10/07/15 2 ADD1 10/28/2015 MECHANICAL SCHEMATICS M-301 AIR HANDLING UNIT SCHEDULE FAN DATA DESIG AHU-1 CFM 8,190 SUPPLY ESP INCH WG 1.5 MOTOR HP 5.0 (2) EXHAUST ESP INCH WG 1.0 CFM 3,710 COOLING COIL DATA LAT °F EAT °F MOTOR HP 3 DB 78.3 WB 65.8 DB 51.9 WB 51.1 HEATING COIL DATA LAT °F EAT °F SENS MBH 234.7 TOTAL MBH 359.2 DB 55.1 ELECTRICAL TOTAL MBH 88.5 DB 65.1 kW 25.9 MCA 169.8 REFRIGERANT R-410A V/PH/HZ 208/3/60 WEIGHT 5492 BASIS OF DESIGN VALENT EER 10.9 REMARKS 1 NOTES: 1. MINIMUM UNIT OUTDOOR AIR IS 3,000 CFM AT 96°F DB/77°F WB. CFM PASS 1 SERVICE PASS 1 AHU-1 PASS 2 3,710 EAT DB (°F) 96.0 3,710 PASS 2 LAT DB (°F) WB (°F) 82.2 69.7 WB (°F) 77.0 AIR PD (IN H2O) 1.0 EAT DB (°F) WB (°F) 75.0 62.5 PASS 1 LAT DB (°F) WB (°F) - EAT DB (°F) WB (°F) 27.0 20.9 AIR PD (IN H2O) 1.0 WT KEH-01 SERVICE OVEN/RANGE LENGTH (IN) 30 DUCT (DIA.) 12" CFM 510 ELECTRICAL (V/PH/HZ) 120/1/60 FIRE SYSTEM PIPING YES DESIGNATION EDH-01 SERVICE FCU-01 MBH 26.4 NUMBER OF ELEMENTS 1 KW 7.7 ELECTRICAL 208/3/60 BASIS OF DESIGN GREENHECK GRRS-30-T-E-D-N AIRFLOW OCCUPIED DESIGNATION MAXIMUM MINIMUM VAV-01 2325 CFM 2100 CFM VAV-02 2325 CFM 2100 CFM VAV-03 935 CFM 900 CFM VAV-04 360 CFM 300 CFM VAV-05 480 CFM 420 CFM VAV-06 400 CFM 320 CFM VAV-07 800 CFM 700 CFM VAV-08 565 CFM 500 CFM REMARKS 2 ELECTRIC DUCT HEATER SCHEDULE BASIS OF DESIGN GREENHECK REMARKS 1,2 LIGHTING: EQUIPMENT: PEOPLE (SENSIBLE): PEOPLE (LATENT): 1.0 - 2 W/SF 1.5 - 2.5 W/SF 245 BTUH/PERSON 205 BTUH/PERSON 70°F±2°F INLET SIZE 16"ø 16"ø 12"ø 6"ø 8"ø 6"ø 10"ø 10"ø OUTLET SIZE 24"x18" 24"x18" 16"x15" 12"x8" 12"x10" 12"x8" 14"x12" 14"x12" MAXIMUM AIR PRESSURE MAXIMUM DROP NC 30 0.01 in-wg 30 0.01 in-wg 30 0.01 in-wg 30 0.01 in-wg 30 0.01 in-wg 30 0.01 in-wg 30 0.01 in-wg 30 0.01 in-wg MINIMUM INLET SP 0.50 in-wg 0.50 in-wg 0.50 in-wg 0.50 in-wg 0.50 in-wg 0.50 in-wg 0.50 in-wg 0.50 in-wg RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 HEATING COIL PERFORMANCE EAT 55 °F 55 °F 55 °F 55 °F 55 °F 55 °F 55 °F 55 °F LAT 85 °F 85 °F 85 °F 85 °F 86 °F 85 °F 86 °F 85 °F kW 20 kW 20 kW 9 kW 3 kW 4 kW 3 kW 7 kW 5 kW NUMBER OF ROWS 1 1 1 1 1 1 1 1 BASIS OF DESIGN REMARKS TITUS DESV TITUS DESV TITUS DESV TITUS DESV TITUS DESV TITUS DESV TITUS DESV TITUS DESV OA CFM 170 MCA 42 1 1 REFRIGERANT R-410A R-410A R-410A DB 78 75.0 75.0 WB 68 62.0 62.0 COIL DUTY COOLING CAPACITY SENSIBLE (MBH) TOTAL (MBH) 42.8 26.1 15.0 14.7 17.0 17.0 HEATING CAPACITY TOTAL (MBH) 28.4 11.7 13.4 ELECTRICAL (V/PH/HZ) 208/3/60 208/1/60 208/1/60 MOUNTING IN CEILING WALL MOUNTED WALL MOUNTED GI BASIS OF DESIGN TRANE MITSUBISHI MITSUBISHI REMARKS Comments New New New DESIG ACCU-01 ACCU-02 ACCU-03 COOLING CAPACITY (MBH) 26.1 17.2 17.2 OUTDOOR FAN NO MOTOR 1 1 1 ELECTRICAL 6. MINIMUM BUILDING POSITIVE PRESSURE: 75°F±2°F / 50% RH 0.05" WG 7. GENERAL EXHAUST CRITERIA: TOILETS/URINALS/SHOWERS: 8. CODES: INTERNATIONAL BUILDING CODE, 2012 INTERNATIONAL MECHANICAL CODE, 2012 INTERNATIONAL PLUMBING CODE, 2012 INTERNATIONAL ENERGY CONSERVATION CODE, 2009 NATIONAL ELECTRIC CODE, 2011 NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS (LATEST EDITIONS) 75 CFM/FIXTURE S O UT H C A R RMF ENGINEERING INC. CHARLESTON, SC C-00831 ST E R E D E N G IN E E Construction Documents FLA .93 .93 (V/PH/HZ) 208/1/60 208/1/60 208/1/60 OUTDOOR DESIGN TEMP (°F DB) MCA 18 14 14 MOCP 30 15 15 SUMMER 95 95 95 WINTER 27 27 27 COMPRESSOR NO 1 1 1 REFRIGERANT R-410A R-410A R-410A WEIGHT LBS. 234 119 119 BASIS OF DESIGN TRANE MITSUBISHI MITSUBISHI REMARKS Hardeeville Welcome Center Replacement FAN SCHEDULE DESIG EF-01 EF-02 EF-03 EF-04 EF-05 EF-06 EF-07 EF-08 KEF-01 SERVICE EXHAUST EXHAUST EXHAUST EXHAUST EXHAUST EXHAUST EXHAUST EXHAUST EXHAUST TYPE CABINET INLINE INLINE CABINET CABINET CABINET CABINET CABINET INLINE CFM 150 CFM 1650 CFM 1100 CFM 150 CFM 100 CFM 100 CFM 100 CFM 100 CFM 510 CFM SP INCH H2O 0.20 0.25 0.25 0.20 0.20 0.20 0.20 0.20 0.25 APPROX RPM 1050 1140 1725 1050 1050 1050 1050 1050 1300 BHP - HP (MOTOR SIZE) 128 W 1/6 1/4 128 W 128 W 128 W 128 W 128 W 1/15 DRIVE DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT ELECTRICAL 120/1/60 120/1/60 120/1/60 120/1/60 120/1/60 120/1/60 120/1/60 120/1/60 120/1/60 VFD NO NO NO NO NO NO NO NO NO EMERGENCY POWER APPROX WEIGHT (LBS) NO 10 NO 67 NO 56 NO 10 NO 10 NO 10 NO 10 NO 10 NO 41 BASIS OF DESIGN GREENHECK GREENHECK GREENHECK GREENHECK GREENHECK GREENHECK GREENHECK GREENHECK GREENHECK REMARKS - 5. COMFORT COOLING: INTERIOR SPACES F EO AIR COOLED CONDENSER SCHEDULE 0.048 0.048 0.286 0.311 4. COMFORT HEATING: INTERIOR SPACES MAX CFM 1220 720 830 95.5°F DB / 77.3°F WB 83.4°F DB / 77.9°F WB 27°F 3. GENERAL BUILDING DESIGN LOAD REQUIREMENTS: 843.762.2222 843.762.2300 VALENT T DESIG FCU-01 FCU-02 FCU-03 2. GENERAL BUILDING CRITERIA: WALL U-FACTOR: ROOF U-FACTOR: GLASS U-FACTOR: GLASS SHADING COEFFICIENT: www.liollio.com IN A EAT °F 2 SUMMER: SUMMER (DEHUMIDIFICATION): WINTER: BASIS OF DESIGN FAN COIL UNIT SCHEDULE FAN 1. OUTSIDE DESIGN CONDITIONS: WB (°F) 45.6 TYPE AIR PD (IN H2O) 1.0 ENTHALPY PLATE OL NOTES: 1. THE ELECTRIC DUCT HEATER SHALL BE PROVIDED WITH AN INTEGRAL DISCONNECT WITH PRIMARY POWER FUSING. 2. PROVIDE SCR CONTROLS FOR ELECTRIC DUCT HEATER. BUILDING DESIGN COMMISSIONING DATA DB (°F) 55.3 AIR PD (IN H2O) 1.0 SUPPLY VAV UNIT SCHEDULE KITCHEN VENTILATION HOOD SCHEDULE MAX COOKING TEMP (°F) 190 LAT PASS 2 EAT DB (°F) WB (°F) 70.0 58.5 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 RS PHX-1 WINTER ST A DESIG SUMMER RE C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. HEAT EXCHANGER SCHEDULE OSE Project Number: Project Number: Checked By: Drawn By: 2 AIR DEVICE SCHEDULE CFM NUMBER A1 A2 A3 C1 C2 C3 E2 E3 E4 G1 G2 G3 K1 K2 DUTY SUPPLY SUPPLY SUPPLY RETURN RETURN RETURN EXHAUST EXHAUST EXHAUST SUPPLY SUPPLY SUPPLY RETURN RETURN TYPE A A A C C C E E E G G G K K MIN 0 CFM 151 CFM 251 CFM 0 CFM 0 CFM 0 CFM 126 CFM 226 CFM 351 CFM 0 CFM 661 CFM 901 CFM 0 CFM 326 CFM MAX 150 CFM 250 CFM 350 CFM 800 CFM 800 CFM 800 CFM 225 CFM 350 CFM 500 CFM 660 CFM 900 CFM 1200 CFM 325 CFM 980 CFM NECK SIZE 6"ø 8"ø 10"ø 18"x18" 18"x18" 18"x18" 8"x8" 10"x10" 12"x10" 8"ø 12"ø 12"ø 8"ø 12"ø BLOW 4-WAY 4-WAY 4-WAY - Date: BASIS OF DESIGN MANUFACTURER TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS Revisions: MODEL TDCA TDCA TDCA PAR PAR PAR PAR-AA PAR-AA PAR-AA FL-20 FL-20 FL-20 FL-20 FL-20 DESIGNATION IAH-01 CFM 200 THROAT VELOCITY (FPM) 475 THROAT AREA (SF) 0.44 HOOD AREA (SF) 4.2 14108 DWZ TJR 10/07/15 2 ADD1 10/28/2015 REMARKS MECHANICAL SCHEDULES M-500 INTAKE AIR HOOD SCHEDULE MAXIMUM AIR PD (INCH WG) 0.03 Interstate 95, Jasper County, SC P28-9742-PD WEIGHT (LBS) 37 BASIS OF DESIGN GREENHECK DRAWING NOTES 4 5 6 2 OWNER PROVIDED CONTRACTOR INSTALLED PEOPLE COUNTER. PROVIDE 3/4" CONDUIT TO MECH/ELEC 114 FOR WIRING BY OWNER. 2 PROVIDE 1 1/4" CONDUIT TO ROOF FOR ANTENNA. PROVIDE WEATHERHEAD CAP. 3 PROVIDE 120V CONNECTION TO HOOD AND KITCHEN EXHUAST FAN. PROVIDE SINGLE POLE MOTOR RATED SWITCH FOR DISCONNECTING MEANS FOR FAN. PROVIDE FIRE ALARM RELAY TO ALERT SYSTEM OF FIRE PROTECTION ACTIVATION IN HOOD. RANGE CIRCUIT SHALL SHUNT TRIP UPON ACTIVATION. 4 2 CHANNEL EXTRUSION BY CURTAIN WALL MANUFACTURER FOR FIRE ALARM AND TELECOMM WIRING. SEE ARCHITECTURAL PLANS FOR INFO. 5 FLOOR BOX FOR POWER AND TELECOMM. PROVIDE 1" CONDUIT TO ROOM 120 FOR IT CABLING. 6 1" CONDUIT TO ACCESSIBLE CEILING IN PLUMBING CHASE 115 FOR IT CABLING. 7 1 1/4" CONDUIT UNDER SLAB TO IT/ELEC 120. 8 4" SLEEVE. 9 3/4" x 4' x 8' PLYWOOD BACKBOARD WITH FIRE RESISTANT PAINT IN LIGHT COLOR, APPLY TO ALL WALLS. 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 11 120V CONNECTION FOR FCU MOTORIZED DAMPER P FCU-01 J 44 20 2 J FAN CONTROLLERS 1 116 32,34,36 E +60" 34 34 RCP-01 14 MDP 1 M M EF-03 5 J J 10 12 +46"+46" +46"+46" F GFI 4 18 14 +46"+46" E 13,15,17 VAV-04 VAV-05 5 J J 11 100 24 J 5 11 J 5 J 7 E 29 J 11 19 GFI 5 J 13 J 11 VESTIBULE GFI WOMEN B 16 J 15 JAN. 13 13 13 13 13 13 13 13 J J J J J J J J J J J 16 J 7 J 7 PLUMBING CHASE M M EF-02 5 105 J J J J J J J J 7 7 7 7 7 7 7 7 106 11 13 GFI J 13 13 J J AUTO FAUCET/TOILET DISCONNECTS, TYP. J J J GFI 5 7 7 7 M 16 MEF-07 J 7 16 M 9 J 108 36 +48" 1 11 F 19 FAMILY B +48" GFI 17 2 E 2 6 111 15 VAV-06 E 19,21,23 GFI CUSTODIAL 15 110 F 6 1 C 21 20 48 Hardeeville Welcome Center Replacement 7 6 35 2 25 21 1 27 8,10,12 NIGHT LOBBY E 20,22,24 120V CONNNECTION FOR PAY PHONE. F 30 37 6 E VENDING STORAGE 109 29 OSE Project Number: 101 Project Number: 31 P F Checked By: J 46 Drawn By: 33 D 21 ADA DOOR ACTUATOR. PROVIDE 1/2" CND TO DOOR OPERATOR. COORDINATE EXACT LOCATION WITH ARCHITECT. TYPICAL. WP/GFI 6 1 E R E D E N G IN E Construction Documents P F 22 J VAV-07 F 1 MOTHER'S ROOM 112 M 25 M VAV-03 E 25,27,29 F M EF-04 5 E 7,9,11 3 +48" 19 C ST 101B 39 +72" 41 PROVIDE CONNECTION TO OVERHEAD DOOR. PROVIDE CONDUIT AND 2#12 AWG TO BASE OF 23 GATE AT EACH SIDE FOR SENSORS VAV-08 102 103 GFI 38 34 J S VAV-02 107 VESTIBULE WOMEN A F 3 GFI 13 GFI 13 42 F 3 M EF-05 FAMILY A 104 13 M J J 27 F 3#12 AWG S RMF ENGINEERING INC. CHARLESTON, SC C-00831 F F F 28 28 K +100" J F S F 11 +100" M 25 M EF-06 J +100" J S PROVIDE ROUGH-IN FOR KEY SWITCH +60"+60" GFI 26 F 26 S +100" 41 S GFI +60"+60" +100" 41 R 13 19 GFI JAN. EF-08 +100" 41 S O UT H C A MECHANICAL ENCLOSURE GFI 3 COORDINATE FINAL LOCATION AND MOUNTING HEIGHT WITH OWNER, TYP. F EO 9 J 32 J 32 B GI 114 MOUNT TIGHT UNDER COUNTER TYP. 5 WC1 SEC2 - 2,4 ACCU-03 J 11 3 WELCOME CENTER TO FCU-03 WP/GFI 23 E 14,16,18 J 11 5 J 113 5 D MEN A MEN B J 32 19 CONNECTION TO FAN, PROVIDE WALL CONTROL IN STAFF WORK ROOM 117 FOR EACH FAN 17 5 5 J PROVIDE EMPTY POWER AND F DATA JUNCTION BOX WITH 3/4" CONDUIT FROM EACH BOX FOR FUTURE MONITORS. HOMERUN ALL CONDUITS TO ROOM 120. COORDINATE FINAL ROUGH-IN LOCATION WITH OWNER. 1 9 GFI PLUMBING CHASE 5 J J 11 115 F MANAGER OFFICE 18 118 F 17 J 11 5 18 F 21 WP/GFI NEMA 6-50R 3 5 J IN A 4 16 J 11 OL 26 J 18 ARM 36,38 B 1,3,5 M 5 J GFI 6 GFI 4 23 AHU-01 J 40 119 COORDINATE DISCONNECT SWITCH TYPE WITH MANUFACTURER. WP/GFI T F PROVIDE CONNECTION TO PREWIRED CASEWORK, COORDINATE LOCATION WITH J CASEWORK MANUFACTURER 32 19 22 11 2 2 FACP 8 J 11 PROVIDE 30A, 3-POLE, 240V NFSS. TYPICAL FOR ALL DUCT HEATERS. ST A 20 J 117A KITCHEN D M 25 STAFF WORK ROOM 6 FROM ACCU-03 10 RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 F 10 FCU-03 E MAIN GROUND BUS J 49 BAR, SEE ONE-LINE MOD J 49 WC1 MOD P 24 1 SEC2 WC1 J J GROUND BUS BAR E 2,4,6 DWH-01 +60" 32 16 S A FOR IRRIGATION CONTROLLER 11 MECHANICAL EDH-01 E 2 IT/ELEC 120 4 GFI FCU-02 11 2 WP/GFI MDP 37,39,41 E VAV-01 FS TS F GFI MDP E 31,33,35 F P 9 WC1 - 45 J P 8 J 39 18 STAFF TOILET WC1 SEC2 - 6,8 M 2 TO FCU-02 121 FROM ACCU-02 F M F EF-01 +48" 47 J 843.762.2222 843.762.2300 J E www.liollio.com RS MDP - 38,40,42 120V CONNECTION TO SPRINKLER ELECTRIC BELL. WIRE THROUGH FLOW SWITCH. GFI E COORDINATE EXACT QUANTITY AND LOCATION WITH FIRE ADA DOOR ACTUATOR. PROVIDE PROTECTION DRAWINGS. 1/2" CND TO DOOR OPERATOR. COORDINATE EXACT LOCATION WITH ARCHITECT. TYPICAL. GFI ACCU-02 ACCU-01 RE C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. 2 1 Date: Revisions: Interstate 95, Jasper County, SC P28-9742-PD 14108 BAC MDA 10/07/15 1 10/07/15 REBID 2 ADD1 10/28/2015 3 ELECTRICAL POWER AND SPECIAL SYSTEMS PLAN 1 ELECTRICAL POWER AND SPECIAL SYSTEMS PLAN SCALE: 1/8" = 1'-0" E-100 GRAPHIC SCALE 8 N 4 0 SCALE: 1/8" = 1'-0" UNIT OF MEASURE: FEET 8 16 4 5 6 C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 www.liollio.com 843.762.2222 843.762.2300 A 121 BC-01 FCU-03 IT/ELEC 120 FCU-05 2 WC1 SEC2 - 2,4 E MECHANICAL STAFF TOILET 2 E WC1 SEC2 10,12 STAFF WORK ROOM STAFF STORAGE ROOM 117A 117B RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 116 2 E WC1 SEC2 - 2,4 KITCHEN 119 EDH-01 MDP - 37,39,41 120V CONNECTION FOR FCU MOTORIZED E DAMPER, TYPICAL J WC1 SEC2 EDH-04 WC1 - 45 10,12 MDP - 38,40,42 FCU-01 E 2 13 MANAGER OFFICE PLUMBING CHASE 118 MEN A 114 RE B 115 GI E MDP 31,33,35 ACCU-01 MEN B S O UT H C A R RMF ENGINEERING INC. CHARLESTON, SC C-00831 ST RS T ST A MECHANICAL ENCLOSURE F EO IN A WC1 SEC2 6,8 2 E E J FCU-04 WC1 - 45 OL EDH-02 MDP - 38,40,42 WC1 - 45 J E 2 E WC1 SEC2 FCU-02 6,8 E R E D E N G IN E E Construction Documents 113 WELCOME CENTER 100 JAN. CUSTODIAL 112 110 Hardeeville Welcome Center Replacement VESTIBULE FAMILY B 101B 111 C WOMEN B FAMILY A VENDING STORAGE 104 107 109 JAN. 106 PLUMBING CHASE NIGHT LOBBY VESTIBULE 105 101 102 OSE Project Number: Project Number: WOMEN A MOTHER'S ROOM 103 Checked By: 108 Drawn By: Date: D 1 2 Revisions: Interstate 95, Jasper County, SC P28-9742-PD 14108 BAC DWT 10/07/15 2 ADD1 10/28/2015 3 2 ELECTRICAL POWER PLAN (MECHANICAL EQUIPMENT ALTERNATE) 1 ELECTRICAL POWER PLAN (MECHANICAL EQUIPMENT ALTERNATE) SCALE: 1/8" = 1'-0" E-100A GRAPHIC SCALE 8 N 4 0 SCALE: 1/8" = 1'-0" UNIT OF MEASURE: FEET 8 16 GENERAL NOTES 4 5 1. PROVIDE TIME CLOCK CONTROL OF EXTERIOR FIXTURES. LOCATE TIME CLOCK IN ROOM 116. 6 DRAWING NOTES 3 UL1 30 DIMMER SWITCH FOR ROOM 100 TYPE W2 LIGHTING. 2 PROVIDE (2) 4' SECTIONS ON BATTERY BACKUP. PROVIDE 125W INVERTER SYSTEM IN ROOM 116. 3 PROVIDE 100W INVERTER FOR TYPE UL1 FIXTURE. LOCATION IN ROOM 116. 4 PROVIDE 200W INVERTER FOR TYPE UL1 FIXTURE. LOCATION IN ROOM 120. 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 www.liollio.com 843.762.2222 843.762.2300 UL1 30 W3 30 W3 30 UL1 30 A W1 37 OS R1 37 R1 37 R1 37 EM 31 1 OS OS 121 IT/ELEC S1 37 120 R1 37 S1 31 S1 31 S1 31 STAFF STORAGE ROOM 2 OS R1 37 R1 37 R1E 37 1 MECHANICAL 117B R1E 37 RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 W3 30 Da D2 37 D2 37 STAFF TOILET R1 37 1 116 R1 37 R1 37 D1 31 D1 31 D1 31 D1 31 KITCHEN UC1 6 1 117A R1 37 R1 37 2 R2 37 a,b R2 37 a,b R1 37 2 X1 37 OS UC1 10UC1 10 UC1 14 UC1 14 UC1 14 MANAGER OFFICEOS 2 118 UL1 30 UL1 30 W2 28 a UL1 30 32' SECTION W2 28 a 4 52' SECTION D1 31 D1 31 D1 31 PLUMBING CHASE 115 S1 31 B GI D1 31 D1 31 F EO S O UT H C A R RMF ENGINEERING INC. CHARLESTON, SC C-00831 ST E R E D E N G IN E E D1 31 MEN B R3 31 1 D1E 31 D1 31 D1 31 D1E 31 D1 31 MECHANICAL ENCLOSURE 13 D1 31 OS D1 31 Construction Documents R3 31 113 100 D1 31 MEN A 114 D1 31 D1E 31 D1 31 WELCOME CENTER 2 D1 31 D1 31 D1E 31 UL1 30 D1 31 D1 31 2 D1E 31 IN A D1 31 UC1 6 D1 31 OL a b R1E 37 S1 31 D1 31 D1E 31 RS W2 42 a 23' SECTION STAFF WORK ROOM T R1E 37 ST A 119 RE JAN. 112 UL1 30 UL1 30 X1 28 W2 28 a 52' SECTION W1 33 OS D2 33 OS 2 UL1 30 UL1 30 D2 33 R1 33 D1E 33 S2 33 W3 30 CUSTODIAL FAMILY B 110 X1 33 111 C OS D1E 35 D1 35 D1E 35 D1 35 D1E 35 D1 35 D1E 35 1 WOMEN B 1 104 D1 35 R3 35 PLUMBING CHASE D1 33 R3 35 D1 35 D1 35 D1 35 D1 35 D1 35 D1 35 D1 35 D1 35 D1 35 D1 35 D1 35 WOMEN A D1 33 103 D1 35 D1E 35 D1 35 D1E 35 D1 35 D1E 35 D1 35 OS D1E 35 R1 33 D1E 33 D1E 33 D1 33 D1 33 D1 33 D1 33 D1 33 D1 35 2 W1 33 R3 33 MOTHER'S ROOM 108 D2 33 D1 35 R1 33 NIGHT LOBBY VENDING STORAGE 101 D1 33 D1 33 109 D1E 33 OSE Project Number: R1 33 Project Number: X1 33 D1E 30 Checked By: Drawn By: D1E 30 W1 33 1 2 Hardeeville Welcome Center Replacement D2 33 D1E 33 D1 33 VESTIBULE D1 33 X1 33 102 S1 35 105 1 JAN. 106 D1 35 D1 35 D1 35 D1 35 D1 35 D1 35 D1 35 D1 35 D1 35 D1 35 S1 35 FAMILY A D2 33 107 D1 35 OS D1 35 OS C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. UL1 30 1 D Date: Revisions: Interstate 95, Jasper County, SC P28-9742-PD 14108 BAC MDA 10/07/15 1 10/07/15 REBID 2 ADD1 10/28/2015 3 ELECTRICAL LIGHTING PLAN 1 ELECTRICAL LIGHTING PLAN SCALE: 1/8" = 1'-0" E-200 GRAPHIC SCALE 8 N 4 0 SCALE: 1/8" = 1'-0" UNIT OF MEASURE: FEET 8 16 GENERAL NOTES: 1. PRIMARY CONDUIT AND CONDUCTORS TO BE PROVIDED BY ELECTRIC UTILITY COMPANY. COORDINATE TRANSFORMER PAD LOCATION WITH UTILITY ALL LOADS ARE NOT SHOWN ON THE SINGLE LINE DIAGRAM. REFER TO PANEL SCHEDULES FOR REMAINING LOADS. DRAWING NOTES: 1 TRANSFORMER PROVIDED BY UTILITY COMPANY. CONTRACTOR TO PROVIDE CONCRETE TRANSFORMER PAD, AND SECONDARY LUGS. 2 UL LISTED FOR SERVICE ENTRANCE. SINGLE PHASE PROTECTION BUILT INTO SERVICE ENTRANCE MAIN CIRCUIT BREAKER 1 EXOTHERMIC WELD. TYPICAL. PAD-MOUNTED UTILITY TRANSFORMER PROVIDED BY POWER COMPANY 208Y/120V, 3Ø, 4W SECONDARY MAIN GROUND BAR (MGB) RM 116 TIED OR WELDED REBAR # 3/O BARE COPPER GROUNDING CONDUCTOR M MOUNTED ON UTILITY TRANSFORMER, COORDINATE REQUIREMENTS # 3/O BARE COPPER GROUNDING CONDUCTOR 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 www.liollio.com 843.762.2222 843.762.2300 RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 30' LENGTH MIN. IN FOOTING # 3/O BARE COPPER GROUNDING CONDUCTOR BUILDING STEEL COLUMN AND UFER GROUND. REFER TO DETAILS FOR FURTHER GROUNDING REQUIREMENTS. BOND TO WATER PIPE WITHIN 5 FT. OF WHERE PIPE ENTERS THE BUILDING USING UL APPROVED CLAMP. TYP. MAIN WATER SERVICE PIPE WHEN METALLIC. GROUNDING GRID GI FEEDER SCHEDULE (600V UNLESS OTHERWISE NOTED) EXAMPLE: P-100 M-30 TP-75 LEGEND: P - PANEL M - MOTOR TP/TS - XFMR (PRIMARY/SECONDARY) PANEL MDP WC 208/120V, 3Ø, 4W 65K AIC MIN - SE RATED 100% RATED 800A MAIN CIRCUIT BREAKER GND. GFP MAIN BONDING JUMPER NEUT. 2 SETS SIZE GROUND 4" P-150 1 4#1/0 #6 2" #10 1 1/4" P-200 1 4#3/0 #6 2" 4#12 #12 3/4" P-225 1 4#4/0 #4 2 1/2" 1 4#10 #10 1/2" P-250 1 4#250 #4 2 1/2" P-40 1 4#8 #10 3/4" P-300 1 4#350 #4 3" P-50 1 4#8 #10 1" P-400 1 4#500 #3 3 1/2" 4#350 #1 3" SETS SIZE GROUND MAIN 2 4#500 - SPD 1 4#6 P-20 1 P-30 P-35 DM P-45 200/3 70/3 70/3 30/3 20/3 20/3 20/3 30/3 1 4#6 #10 1 1/4" P-600 1 4#4 #8 1 1/4" P-800 2 4#500 #1/0 3 1/2" 1 4#3 #8 1 1/4" P-1200 4 4#350 #3/0 3" P-110 1 4#2 #6 1 1/2" P-1600 5 #400 #4/0 3" P-125 1 4#1 #6 2" CH 1 4#3 #6 4" FPE 1 4#2/0 #4 4" GEN1 1 4#3/0 #6 4" GEN2 2 4#500 #1/0 4" FPT 1 4#2/0 - 4" 20/3 P-70 P-90 SPD CONDUIT 2 P-60 200/3 60/3 P-200 P-80 P-100 PANEL WC1 M E SUB-FEED LUGS VAV-01 AHU-01 E E VAV-02 VAV-03 E VAV-04 E VAV-05 E VAV-06 E VAV-07 CONDUIT LABEL LABEL P-25 2 - 100A PANEL FEEDER - 30HP MOTOR FEEDER - 75KVA TRANSFORMER PRIMARY E R RMF ENGINEERING INC. CHARLESTON, SC C-00831 ST RS T ST A # 2 COPPER TO TELEPHONE GROUND BAR RM 121 S O UT H C A IN A MAIN F EO OL #3/0 COPPER GROUNDING CONDUCTOR RE E R E D E N G IN E E Construction Documents Hardeeville Welcome Center Replacement OSE Project Number: Project Number: VAV-08 Checked By: SPD PANEL WC1 SEC2 Drawn By: FEEDER SCHEDULE (600V UNLESS OTHERWISE NOTED) S.T. LEGEND: P - PANEL M - MOTOR TP/TS - XFMR (PRIMARY/SECONDARY) 2#8, 1#10 GND, 3/4" CND LOCATE IN ROOM 120 208-240V BUCK-BOOST TRANSFORMER 50A ENCLOSED CIRCUIT BREAKER B C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. CONCRETE FOOTING OVEN/RANGE RECEPTACLE LABEL SETS SIZE GROUND M-10 1 3#12 #12 M-15 1 3#10 M-20 1 EXAMPLE: P-100 M-30 TP-75 - 100A PANEL FEEDER - 30HP MOTOR FEEDER - 75KVA TRANSFORMER PRIMARY Revisions: LABEL SETS SIZE GROUND 3/4" TP-75 1 3#1/0 #6 1 1/2" #10 3/4" TP-112 1 3#3/0 #6 2" 3#8 #10 3/4" TP-150 1 3#250 #4 2" 1 3#6 #8 3/4" TP-225 1 3#600 #3 4" M-40 1 3#6 #8 1" TP-300 2 3#250 #2 2 1/2" M-50 1 3#4 #6 1 1/4" TS-15 1 4#8 #8 3/4" M-60 1 3#3 #6 1 1/2" TS-30 1 4#3 #8 1 1/4" M-75 1 3#1 #6 1 1/2" TS-45 1 4#1 #6 1 1/2" M-100 1 3#2/0 #6 1 1/2" TS-75 1 4#250 #2 2 1/2" M-125 1 3#3/0 #4 2" TS-112 1 4#350 #2 3" TP-15 1 3#10 #10 3/4" TS-150 2 4#350 1 3" TP-30 1 3#6 #10 3/4" TS-225 2 4#600 #1/0 3 1/2" TP-45 1 3#3 #8 1 1/4" TS-300 4 4#600 #2/0 3 1/2" M-25 M-30 CONDUIT Date: Interstate 95, Jasper County, SC P28-9742-PD 14108 BAC MDA 10/07/15 2 ADD1 10/28/2015 CONDUIT ELECTRICAL ONE-LINE DIAGRAM E-501 PANELBOARD: MDP LOCATION: MOUNTING: Surface ENCL NEMA: Type 1 MIN AIC: SEE ONE-LINE DIAGRAM MAINS: VOLTS: PHASE: WIRES: AMPS: 800 100% RATED MAIN CIRCUIT BREAKER DISTRIBUTION 208/120 Wye 3 2 4 PANEL NOTES: PROVIDE GROUND BUS PROVIDE FULL SIZE NEUTRAL BUS UNLESS NOTED OTHERWISE TYPE CKT 1 A 22.73 B 22.73 6.67 5 7 3#4, 1#8 GND, 1" VAV-02 CND 3 70 A 6.67 VAV-04 3 20 A 1.00 VAV-06 3 20 A 21 25 3 20 A 31 3#10, 1#10 GND, EDH-01 3/4" CND 3 30 A 37 3 45 A 3 100 A -- 3 VAV-07 3#10, 1#10 GND, 3/4" CND 200 A 3 WC1 4#3/0, 1#6 GND, 2" CND 34 50 A 3 DWH-01 3#8, 1#10 GND, 1" CND 4.33 30 A 3 ACCU-01 3#10, 1#10 GND, 3/4" CND 100 A 3 SPACE 36 38 5.04 2.16 40 5.04 2.16 42 0.00 44 0.00 0.00 46 0.00 83.67 kVA 30 A RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 30 4.33 47 TOTAL LOAD: 21.82 2.16 45 VAV-05 81.74 kVA 0.00 -- -- 48 Load Classification LTG REC Equipment HVAC Lighting - Dwelling Unit GI INDICATES C.B. EQUIPPED WITH "LOCK-ON" DEVICE INDICATES C.B. IS GROUND FAULT TYPE (5mA FOR PERSONNEL) INDICATES C.B. EQUIPPED WITH SHUNT TRIP DEVICE INDICATES C.B. EQUIPPED WITH 30mA GROUND FAULT FOR EQUIPMENT Connected Load 5.98 33.02 33.64 175.13 0.00 Demand Factor 100.00% 65.14% 100.00% 100.00% 0.00% S O UT H C A R RMF ENGINEERING INC. CHARLESTON, SC C-00831 82.32 kVA BREAKER TYPE KEYS: LO GF ST HT - F EO IN A SPACE 3 OL -- 28 2.57 0.00 20 A 32 41 43 VAV-03 24 4.33 39 3 26 2.57 5.04 2.33 21.24 35 3#8, 1#10 GND, 1" FCU-01 CND 22 1.67 33 843.762.2222 843.762.2300 3#10, 1#10 GND, 3/4" CND 35 A 18 23.17 1.67 2.57 1.33 2.33 29 2 16 1.00 1.67 3#4, 1#8 GND, 1" CND VAV-01 20 1.00 27 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 12 2.33 23 VAV-08 3.00 1.33 1.00 1.00 3 WIRE SIZE 14 17 19 70 A LOAD DESCRIPTION www.liollio.com 10 1.33 15 P 6 3.00 6.67 1.00 TRIP AMPS 8 11 13 6.67 3.00 9 TYPE 4 22.73 6.67 CKT 2 6.67 3 200 A C Estimated Demand 5.98 21.51 33.64 175.13 0.00 2 IF ALTERNATE IS ACCEPTED, CIRCUITS 31,33,35 WILL BE FOR ACCU-01. PROVIDE 50A 3P BREAKER, WITH 3#8 1#10GND 1" CONDUIT. THE LOAD WILL BE 4.32KVA. CIRCUITS 37,39,41 WILL BE FOR EDH-01. PROVIDE 20A 3P BREAKER, WITH 3#12 1#12GND 3/4" CONDUIT. THE LOAD WILL BE 3.51KVA. CIRCUITS 32,34,36 WILL BE FOR EDH-02,04. PROVIDE 20A 3P BREAKER, WITH 3#12 1#12GND 3/4" CONDUIT. THE LOAD WILL BE 5.01KVA. Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 247.77 kVA 236.26 kVA 687.74 A 655.79 A ST RS 3 TRIP AMPS T 3#3/0, 1#6 GND, AHU-01 2" CND P ST A LOAD DESCRIPTION RE C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. WIRE SIZE E R E D E N G IN E E Construction Documents Hardeeville Welcome Center Replacement OSE Project Number: Project Number: Checked By: Drawn By: Date: Revisions: Interstate 95, Jasper County, SC P28-9742-PD 14108 BAC MDA 10/07/15 1 10/07/15 REBID 2 ADD1 10/28/2015 ELECTRICAL PANEL SCHEDULES E-601 PANELBOARD: WC1 PANELBOARD: WC1 SEC2 LOCATION: MOUNTING: Surface ENCL NEMA: Type 1 MIN AIC: SEE ONE-LINE DIAGRAM MAINS: VOLTS: PHASE: WIRES: AMPS: 200 MCB LOCATION: MOUNTING: Surface ENCL NEMA: Type 1 MIN AIC: SEE ONE-LINE DIAGRAM 208/120 Wye 3 4 PANEL NOTES: 4 20 A CKT 1 REC MEN B 103 1 20 A 3 SENSORS MEN 103 1 20 A 5 HAND DRYER MEN 103 1 20 A 7 TYPE REC MEN A 105 1 20 A 9 SENSORS MEN 105 1 20 A 11 HAND DRYER MEN 105 1 20 A 13 REC Space 127 1 20 A 15 REC FAMILY B 102 1 20 A 17 REC VESTIBULES, CHASE,... 1 20 A 19 REC VENDING STORAGE... 1 20 A 21 VENDING NIGHT LOBBY 101 1 20 A GF 23 VENDING NIGHT LOBBY 101 1 20 A GF 25 VENDING NIGHT LOBBY 101 1 20 A GF 27 VENDING NIGHT LOBBY 101 1 20 A GF 29 VENDING NIGHT LOBBY 101 1 20 A GF 31 VENDING NIGHT LOBBY 101 1 20 A GF 33 VENDING NIGHT LOBBY 101 1 20 A GF 35 VENDING NIGHT LOBBY 101 1 20 A GF 37 VENDING NIGHT LOBBY 101 VENDING NIGHT LOBBY 101 WELCOME SIGN FCU MOTORIZED DAMPERS ELECTRIC BELL MOTORIZED DAMP. MECH... SPARE SPARE SPARE SPARE SPARE DO NOT USE DO NOT USE DO NOT USE 1 1 1 1 1 1 1 1 1 1 1 ---- 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A ---- GF GF -- 39 41 43 45 47 49 -51 -53 -55 -57 -59 -61 -63 -65 TOTAL LOAD: A 0.36 B C 0.54 0.36 0.54 0.10 1.40 0.40 0.10 0.36 0.18 0.18 1.20 0.36 1.20 0.36 1.20 1.00 0.20 0.18 0.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.34 0.20 0.30 0.00 0.00 8.25 0.00 23.17 kVA TYPE 13.34 21.24 kVA 0.00 9.30 21.82 kVA WIRE SIZE LOAD DESCRIPTION REC MOTHER'S ROOM 108 P 1 20 A P 1 20 A CKT 1 4 20 A 1 REC KITCHEN 115 REC FAMILY A 112 1 20 A 3 6 20 A 1 REC KITCHEN 115 REC WOMEN A 109 1 20 A 5 8 20 A 1 REC STAFF WORK ROOM... SENSORS WOMEN 109 1 20 A 7 LOAD DESCRIPTION REC IT/ELEC 117 WIRE SIZE TYPE 10 20 A 1 REC STAFF WORK ROOM... HAND DRYER WOMEN 109 1 20 A 9 12 20 A 1 REC STAFF WORK ROOM... REC WOMEN B 111 1 20 A 11 14 20 A 1 REC STAFF WORK ROOM... SENSOR WOMEN B 111 1 20 A 13 16 20 A 1 REC STAFF WORK ROOM... HAND DRYER WOMEN 111 1 20 A 15 18 20 A 1 REC MANAGER OFFICE 119 INFORMATION POD WC 100 1 20 A 17 20 20 A 1 REC STORAGE 116 INFORMATION POD WC 100 1 20 A 19 22 20 A 1 CHARGING BAR WELCOME... REC OUTDOOR 1 20 A 21 24 20 A 1 FACP MECHANICAL 116 REC IT/ELEC 120 1 20 A 23 26 20 A 1 REC WELCOME CENTER 100 EF-03, EF-06, EF-08 1 20 A 25 28 20 A 1 REC WELCOME CENTER 100 HAND DRYER WOMEN B 104 1 20 A 27 30 20 A 1 REC WELCOME CENTER 100 HAND DRYER MEN A 114 1 20 A 29 32 20 A 1 CHARGING BARWELCOME... LTG MECHANICAL 116 1 20 A 31 34 20 A 1 REC WELCOME CENTER 100 LTG 1 20 A 33 50 A 2 RANGE KITCHEN 119 LTG WOMEN A 103 1 20 A 35 LTG STAFF WORK ROOM... 1 20 A 37 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 1 1 1 1 1 1 1 1 1 1 1 FRIDGE KITCHEN 119 NIGHT LOBBY GATE ADA DOOR WEL. CTR 100 ADA DOOR NIGHT LOBBY... PAYPHONE NIGHT LOBBY... SPARE SPARE SPARE SPARE SPARE SPARE HAND DRYER STAFF TOIL... DISPLAY SCREEN... 1 1 20 A 20 A 0A 3 WC1 SEC2 36 38 0.18 0.20 5.00 5.00 0.18 0.00 0.18 0.18 1.20 1.20 0.00 0.36 1.20 1.20 0.72 0.36 0.54 1.20 0.36 0.42 0.36 0.72 0.40 0.18 0.36 1.40 CKT 2 40 42 44 46 48 50 52 54 56 58 60 62 64 66 GF ------- 3#8, #10GND, 1" C 2 39 41 TOTAL LOAD: A 0.36 B C 1.46 0.54 1.46 0.00 0.10 1.40 0.40 0.36 1.40 0.36 1.62 1.40 0.08 0.20 0.65 1.40 1.04 1.08 1.40 0.10 1.40 0.99 0.10 0.18 0.18 0.30 0.00 1.40 1.40 1.40 8.25 kVA 0.10 13.34 kVA 0.54 0.28 9.31 kVA P 15 A 2 LOAD DESCRIPTION 147 Wappoo Creek Drive Suite 400 Charleston, SC 29412 WIRE SIZE www.liollio.com ACCU-03 2 6 15 A 8 0.36 0.36 1.46 1.46 1.40 0.14 TYPE 4 0.54 0.14 CKT 2 TRIP AMPS 2 843.762.2222 843.762.2300 ACCU-02 10 -- 20 A 1 SPARE -- 12 -- 20 A 1 SPARE -- 14 30 A 1 RCP-01 2#10, 1#10 GND 16 20 A 1 EF-02, EF-04, EF-05, EF-07 18 20 A 1 EF-01 20 20 A 1 TV NIGHT LOBBY 101 22 20 A 1 HAND DRYER WOMEN A 103 24 20 A 1 HAND DRYER MEN B 113 26 20 A 1 HOOD KITCHEN 119 28 20 A 1 LTG WELCOME CENTER 100 30 20 A 1 LTG 32 20 A 1 CEILING FANS WELCOME... 34 20 A 1 HAND DRYER FAMILY B 111 36 20 A 1 HAND DRYER MOTHER'S... 38 20 A 1 HAND DRYER FAMILY A 107 40 42 20 A 20 A 1 1 FLAG POLE LTG LTG WELCOME CENTER 100 RMF ENGINEERING, INC. 194 Seven Farms Drive, Suite G Charleston, SC 29492 BREAKER TYPE KEYS: ------- LO GF ST HT Load Classification LTG REC Equipment HVAC Lighting - Dwelling Unit INDICATES C.B. EQUIPPED WITH "LOCK-ON" DEVICE INDICATES C.B. IS GROUND FAULT TYPE (5mA FOR PERSONNEL) INDICATES C.B. EQUIPPED WITH SHUNT TRIP DEVICE INDICATES C.B. EQUIPPED WITH 30mA GROUND FAULT FOR EQUIPMENT Connected Load 5.84 3.78 14.68 6.62 0.00 Demand Factor 100.00% 100.00% 100.00% 100.00% 0.00% GI Estimated Demand 5.84 3.78 14.68 6.62 0.00 F EO S O UT H C A R RMF ENGINEERING INC. CHARLESTON, SC C-00831 ST RS P 1 TRIP AMPS T LOAD DESCRIPTION REC MECHANICAL 130 TRIP AMPS ST A TRIP AMPS PROVIDE GROUND BUS PROVIDE FULL SIZE NEUTRAL BUS UNLESS NOTED OTHERWISE IN A C Copyright 2014. All Rights Reserved. Reproduction, copying, or use of this drawing and designs shown thereon without written consent of Liollio Associates, Inc. is prohibited and any infringement is subject to legal action. 3 RE --------- 208/120 Wye OL -- AMPS: 200 MCB PANEL NOTES: PROVIDE GROUND BUS PROVIDE FULL SIZE NEUTRAL BUS UNLESS NOTED OTHERWISE *GFI BREAKER WIRE SIZE MAINS: VOLTS: PHASE: WIRES: E R E D E N G IN E E Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 30.92 kVA 30.92 kVA 85.82 A 85.82 A Construction Documents BREAKER TYPE KEYS: LO GF ST HT Load Classification LTG REC Equipment HVAC Lighting - Dwelling Unit INDICATES C.B. EQUIPPED WITH "LOCK-ON" DEVICE INDICATES C.B. IS GROUND FAULT TYPE (5mA FOR PERSONNEL) INDICATES C.B. EQUIPPED WITH SHUNT TRIP DEVICE INDICATES C.B. EQUIPPED WITH 30mA GROUND FAULT FOR EQUIPMENT Connected Load 5.98 33.02 20.64 6.62 0.00 Demand Factor 100.00% 65.14% 100.00% 100.00% 0.00% Estimated Demand 5.98 21.51 20.64 6.62 0.00 Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 66.26 kVA 54.75 kVA 183.92 A 151.97 A IF ALTERNATE IS ACCEPTED, CIRCUITS 2,4 WILL BE FOR FCU-05, BC-01. PROVIDE 20A 2P BREAKER, WITH 2#12 1#12GND 3/4" CONDUIT. THE LOAD WILL BE 0.88KVA. CIRCUITS 6,8 WILL BE FOR FCU-04, FCU-02. PROVIDE 20A 2P BREAKER, WITH 3#12 1#12GND 3/4" CONDUIT. THE LOAD WILL BE 0.54KVA. CIRCUITS 10,12 WILL BE FOR FCU-03, FCU-01. PROVIDE 20A 2P BREAKER, WITH 3#12 1#12GND 3/4" CONDUIT. THE LOAD WILL BE 1.74KVA. 2 Hardeeville Welcome Center Replacement OSE Project Number: Project Number: Checked By: Drawn By: Date: Revisions: Interstate 95, Jasper County, SC P28-9742-PD 14108 BAC MDA 10/07/15 2 ADD1 10/28/2015 ELECTRICAL PANEL SCHEDULES E-602