transmittal - Log into PIX (Phipps Information Exchange)

Transcription

transmittal - Log into PIX (Phipps Information Exchange)
TRANSM ITTAL
5995 Greenwood Plaza Blvd.
Suite 100
Greenwood Village,CO 80111-4710
303-571-5377
303-629-7467 (fax)
LowryRemodel
PROJECT: DHHA-
DATE: 05/17/2013
Proj
ect #0780 C
TO: Heating
& Plumbing Engrs Inc
407 W Fillmore Pl
Co Springs CO 80907
ATTN: Dave
No.12J2006-0131
DOMESTIC
RE: 22 1116-
WATER PIPIN
Marttila
JOB: 12J2006
Ph/Fax:
W E ARE SENDING:
SUBM ITTED FOR:
ACTION TAKEN:
Shop Drawings
Approval
Approved as Submitted
Letter
Your Use
Approved as Noted
Prints
As Requested
Returned After Loan
Change Order
Review and Comment
Resubmit
Submit
Plans
SENT VIA:
Samples
Returned
Specifications /Product Data
Attached
Returned for Corrections
Other:
Separate Cover Via: Email
Due Date:
NOTES:
Item
Package
Code
Submittal
22 1116
22 1116 -01
Rev. Copies Date
1
05/17/2013
Description
Status
DOMESTIC WATER PIPING -Product Approved
Data
CC:
Signed:
TorreyDeMasters
H+L Architecture | 1755 Blake Street Suite 400 Denver, CO 80202 Submittal Transmittal
Submittal ID:
00045
Transmittal ID: 00233
Date Sent:
Project:
Number:
224.054.00 DHHA Lowry Clinic Remodel
224.054.00
To:
Torrey DeMasters
GH Phipps Construction Companies
496 Nevada Mea View
Colorado Springs, CO 80907
US
719­667­8505 (Phone)
719­471­3169 (Fax)
From:
Jennifer Paddock
H+L Architecture
1755 Blake Street
Suite 400
Denver, CO 80202
303­298­4752 (Phone)
303­292­6437 (Fax)
Subject:
Via:
22 1116­01 Domestic Water Piping PD
Email
Spec Section:
Purpose:
Remarks:
22 1116
No Exceptions Taken
No Exceptions Taken
5/17/2013
The General Contractor is responsible for the detailed review of shop drawings, product
literature, and samples. The GC is to verify that the shop drawings are consistent with
architectural drawings, field conditions, construction tolerances, etc., and must verify that
information shown on one set of shop drawings is fully coordinated with other shops and with
other trades.
CC:
Ed Maxey(Denver Health)
Ryan Bonner(GH Phipps Construction Companies)
John Cooksey(H+L Architecture)
Contents
Quantity:
1
Dated:
Description:
DOMESTIC WATER PIPING ­ Product Data
Action:
No Exceptions Taken
Remarks:
5/8/2013
Number:
22 1116­01
3025 S. Parker Rd | Suite 1100 | Aurora | CO | 80014
(303)696-2602 | www.ssgroupinc.com
SSG MEP, Inc.
Date Received:
May 8, 2013
☒ REVIEWED
☐ REJECTED
☐ REVISE & RESUBMIT
Submittal Number:
12J2006-0091
☐ FURNISH WITH CHANGES NOTED
☐ RESUBMIT SPECIFIC ITEM(S)
☐ TRANSMITTED WITH NO REVIEW MADE
Client/Construction Manager:
G.H. Phipps
Actions taken by SSG MEP, Inc. with respect to the Submittal are only for general
conformance with the design concepts of the Project based upon the Contract
Documents. In all respects, SSG MEP, Inc. is subject to the terms and conditions of its
contract with its Client. Notations, “corrections” or comments on the Submittal(s) do
not modify the obligations of the contractor or its subcontractors from those set forth in
the Contract Documents. Contractor shall field verify, confirm, correlate all dimensions,
sizes and tolerances before construction or installation of any component or assembly
begins. Unless otherwise specifically noted on the submittal, all fabrication, installation and
construction means, methods, techniques, sequences, schedules and procedures remain
solely the responsibility of the contractor. Contractor remains solely responsible for job
site safety and all safety precautions and procedures. Notwithstanding anything else to the
contrary, SSG MEP, Inc. by reviewing this Submittal does not assume professional
responsibility for any design or work product (including but not limited to its technical
accuracy or professional competency) provided by contractor or owner on a “design
build” or “performance specification” basis. SSG MEP, Inc. provides no warranties,
expressed or implied.
Submitting Contractor:
HPE
Reviewed By: AEI
SSG MEP, Inc. Project Number: 10031.03
Date: May 14, 2013
Project Name:
DHHA Lowry Clinic
Project Number:
12J2006
Description:
Domestic Water Piping
A – No Exceptions Taken
C – Rejected
B – Make Correction(s) as Noted, No Resubmittal Required
D – Revise and Resubmit
E – Submit Specified Item
ITEM
REFERENCE
(e.g. spec #
(e.g. page # or paragraph)
COMMENTS
ACTION
(legend above)
or dwg #)
22 1116 –
Domestic Water
Piping
22 1116 –
Domestic Water
Piping
Dielectric Union –
Watts
No comments.
A
Dielectric Waterway –
Victaulic
No comments.
A
File: O:\Data G-L\H+L\DHHA Lowry Clinic\Construction Administration\submittals\Plumbing\2013.05.14 DHHA Lowry Clinic - Domestic
Water Piping Submittal Review.docx
Page 1 of 1
TRANSMITTAL
5995 Greenwood Plaza Blvd.
Suite 100
Greenwood Village, CO 80111-4710
303-571-5377
303-629-7467 (fax)
PROJECT:
TO:
ATTN:
No. 12J2006-0091
DATE: 05/08/2013
DHHA-Lowry Remodel Project #0780 C
H+L Architecture
1755 Blake St #400
Denver CO 80202
RE:
22 1116-DOMESTIC WATER PIPIN
Chad Shaffer
JOB:
Ph/Fax:
WE ARE SENDING:
SUBMITTED FOR:
12J2006
ACTION TAKEN:
Shop Drawings
Approval
Approved as Submitted
Letter
Your Use
Approved as Noted
Prints
As Requested
Returned After Loan
Change Order
Review and Comment
Resubmit
Submit
Plans
SENT VIA:
Samples
Returned
Specifications / Product Data
Attached
Returned for Corrections
Other:
Separate Cover Via: E-Mail
Due Date: 05/22/2013
NOTES:
Item
Package
Code
Submittal
22 1116
22 1116 -01
Rev. Copies Date
1
05/08/2013
Description
Status
DOMESTIC WATER PIPING - Product Architect Review
Data
CC:
Signed:
Torrey DeMasters
Submittal Form
DATE:
4/29/2013
HPE JOB NUMBER:
12311522
HPE JOB NAME:
DHHA Lowry Clinic Remodel
LOCATION:
Denver, CO
ENGINEER:
SSG MEP Inc
ARCHITECT:
GENERAL CONTRACTOR:
VENDOR / SUBCONTRACTOR:
SUBMITTAL ITEM:
SPECIFICATION SECTION:
PARAGRAPH:
H&L Architecture
GH Phipps
HPE
Domestic Water Piping
221116
1.3
DRAWING SHEET:
PROJECT MANAGER:
Mike Milbrodt
COMMENTS:
I hereby certify that this Shop Drawing and/or Brochure & the equipment & materials shown on this Shop drawing and/or Brochure complies in all respects with the
requirements of the contract documents for this project. I further certify that all data shown herein as to performance, dimensions, construction, materials & other pertinent
items are true and correct.
Steve Van Wormer
Project Engineer
407 W. Fillmore Place Colorado Springs, CO 80907 719-633-5414 633-4031
715 Vallejo Street Denver, CO 80204 720-274-0073 274-0419
ES-LF3001A
For Residential and Commercial Applications
Job Name –––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––––
Job Location –––––––––––––––––––––––––––––––––––––––––– Approval – –––––––––––––––––––––––––––––––––––––––––––––
Engineer –––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––
Approval –––––––––––––––––––––––––––––––––––––––––––––– Representative –––––––––––––––––––––––––––––––––––––––––
LEAD FREE*
Series LF3001A
Dielectric Unions
Sizes 1⁄2" – 2" (15 – 50mm)
Series LF3001A dielectric unions feature a female iron pipe
thread to solder connection. These unions are designed to be
installed between pipe made from dissimilar metals to prevent
accelerated corrosion and deterioration in the piping system due
to galvanic and stray current. The LF3001A features Lead Free*
construction to comply with Lead Free* installation requirements.
Features
•Female iron pipe thread to solder connection
•Designed and manufactured to the highest quality standards
•Individually factory certified to withstand a minimum of 600
volts on a dry line with no flashover
•Rated to 180°F (82°C) at 250psi (17.2 bar) with standard
gasket A and 300ºF (149ºC) at 50psi (3.4 bar) with optional
gasket B
Specifications
A dielectric union shall be installed where indicated on the
plans. The union shall feature a female iron pipe thread to solder connection. The dielectric union shall be constructed using
Lead Free* materials. Lead Free* dielectric unions shall comply
with state codes and standards, where applicable, requiring
reduced lead content. The dielectric union shall be a Watts
Series LF3001A that complies with Buy America Act (BAA
1933) and The American Recovery and Reinvestment Act
(ARRA 2009).
LF3001A
Standards
Complies with Buy America Act (BAA 1933) and The American
Recovery and Reinvestment Act (ARRA 2009).
Meets federal specifications for tensile strength and thread end
connections
Pressure — Temperature
Maximum Pressure: 250psi (17.2 bar) with standard gasket A;
50psi (3.4 bar) with optional gasket B
Maximum Temperature: 180°F (82°C) with standard gasket A;
300ºF (149ºC) with optional gasket B
Dimensions — Weights
B
A
SIZE (DN)
Materials
Steel Parts
Brass Parts
Zinc Plating
Standard Gasket A
Optional Gasket B
DIMENSIONS
A
ASTM A108
ASTM B371
ASTM B633-85
Buna-N
EPDM
Options
GB - O
ptional EPDM gasket for use in steam or hot water
applications up to 300ºF (149ºC) at 50psi (3.4 bar).
WEIGHT
B
in.
mm
in.
mm
in.
mm
oz.
gm.
⁄
3⁄4
1
11⁄4
11⁄2
2
15
20
25
32
40
50
11⁄2
15⁄8
17⁄8
21⁄4
23⁄4
31⁄2
32
41
48
57
70
89
17⁄8
21⁄8
21⁄2
3
3
3
48
54
64
76
76
76
6
6.7
9.3
13.3
13.3
34.7
170
190
264
377
377
984
12
*The wetted surface of this product contacted by consumable water
contains less than one quarter of one percent (0.25%) of lead by weight.
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts
reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications
on Watts products previously or subsequently sold.
USA: No. Andover, MA • Tel. (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com
Canada: Burlington, ONT. • Tel. (905) 332-4090 • Fax: (905) 332-7068 • www.wattscanada.ca
ES-LF3001A 1109
A Watts Water Technologies Company
© 2011 Watts
09.07
IPS CARBON STEEL PIPE – GROOVED ACCESSORIES
Dielectric Waterway
SBCCI
Series 47
Clearflow* Dielectric Waterway fittings create a dielectric waterway by insulating the inside of
the metal casing, thus inhibiting the internal formation of galvanic local cell corrosion between
the dissimilar metals in the presence of water.
By essentially eliminating galvanic local cell and stray current problems, Clearflow Dielectric
Waterway fittings continuously provide the most effective corrosion protection possible in any
waterway system connection.
Style 47-GT
Grooved End X Threaded
Clearflow fittings use materials which meet the requirements of ASTM F-1545-97. Clearflow
fittings are designed for continuous use at temperatures up to 230°F (110°C) and pressures
up to 300 psi/2065 kPa.
Style 47-TT
Threaded X Threaded
Style 47-GT and 47-TT are NSF Listed in accordance with ANSI/NSF 61, up to 180°F (82°C)
for potable water service. Style 47-GG is UL Classified in accordance with ANSI/NSF 61, up to
180°F (82°C) for potable water service.
Varied Styles
Clearflow Dielectric Waterways provide a transition from steel (IPS) pipe to copper (CTS) pipe
with varied end preparations.
Style 47-GT connects a threaded (IPS) copper adapter to a grooved steel system. The threaded by threaded Style 47-TT connects the threaded copper adapter to a FPT component.
The new Style 47-GG provides a direct transition from grooved copper (CTS) to grooved end
steel (IPS) without any other adapters. This allows easy integration of Victaulic grooved end
copper systems into steel systems. This is significant for retrofit, expansion or direct connection to dissimilar metals equipment.
*Clearflow is a registered trademark of Perfection Corp.
2-4"/50-80 mm
5-8"/100-200 mm
Style 47-GG
Grooved End Steel (IPS) to Grooved
Copper (CTS) Transition Fitting
material specifications
1
2
3
1. Inert, non-corrosive thermoplastic lining (NSF/FDA listed)
2. Patented ring-groove locks the steel casing to the thermo-plastic lining, or molded liner with
identifying roll marking on casing.
3. Zinc electroplated casing, threaded in accordance with American National Pipe Thread – Tapered
ANSI A1.20.1
Optional Coating: TNEMEC N-140 Pota-Pox Plus (ANSI/NSF-61 Compliant)
Body (Styles GT and TT): Steel pipe to ASTM A-53, zinc electroplated.
Body (Style GG):
2-4"/50-80 mm Sizes: Ductile iron conforming to ASTM A-536, grade 65-45-12, and ASTM A-395,
grade 65-45-15, zinc electroplated
5-8"/114.3-219.1 mm Sizes: Steel pipe to ASTM A‑53, zinc electroplated.
Liner: LTHS high temperature stabilized polyolefin polymer (virgin polypropylene)
JOB/OWNER
CONTRACTOR
ENGINEER
System No._______________________________
Submitted By_____________________________
Spec Sect________________Para____________
Location_ ________________________________
Date____________________________________
Approved_ _______________________________
Date____________________________________
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED.
REV_G
09.07_1
09.07
IPS CARBON STEEL PIPE – GROOVED ACCESSORIES
Dielectric Waterway
Series 47
DIMENSIONS
Pipe Size
E to E
Actual
Out. Dia.
Inches/mm
Max. Work. Press.
PSI/kPa
End to End
Inches/mm
Units
Per Box
Aprx. Wgt. Each
Lbs./kg
1
25
1.315
33.7
300
2065
4.00
102
25
0.3
0.2
1 1/4
32
1.660
42.4
300
2065
4.00
102
10
0.6
0.3
1 1/2
40
1.900
48.3
300
2065
4.00
102
10
0.8
0.3
2
50
2.375
60.3
300
2065
4.00
102
10
1.0
0.5
2 1/2
65
2.875
73.0
300
2065
6.00
152
6
1.6
0.7
3
80
3.500
88.9
300
2065
6.00
152
6
2.0
0.9
3 1/2
90
4.000
101.6
300
2065
6.00
152
6
2.3
1.1
4
100
4.500
114.3
300
2065
6.00
152
6
4.5
2.0
1/2
15
0.840
21.3
300
2065
3.00
76
25
0.2
0.1
3/4
20
1.050
26.7
300
2065
3.00
76
25
0.2
0.1
1
25
1.315
33.7
300
2065
4.00
102
25
0.3
0.2
1 1/4
32
1.660
42.4
300
2065
4.00
102
10
0.6
0.3
1 1/2
40
1.900
48.3
300
2065
4.00
102
10
0.8
0.3
2
50
2.375
60.3
300
2065
4.00
102
10
1.0
0.5
2 1/2
65
2.875
73.0
300
2065
6.00
152
6
1.6
0.7
3
80
3.500
88.9
300
2065
6.00
152
6
2.0
0.9
3 1/2
90
4.000
101.6
300
2065
6.00
152
6
2.3
1.1
4
100
4.500
114.3
300
2065
6.00
152
6
4.5
2.0
Nominal
Dia.
Inches/mm
Grooved X Threaded
Style 47-GT
Grooved X Threaded
E to E
Threaded X Threaded
Style 47-TT
Threaded X Threaded
Grooved X Grooved
Grooved End Steel to Grooved Copper Transition
Pipe Size
Inches/mm
E to E
Style 47-GG
Grooved X Grooved
Actual Outside Diameter
Nominal
Diameter
Steel (IPS)
Copper (CTS)
Max. Work.
Press.
PSI/kPa
End to End
Inches/mm
Units
Per Box
Aprx. Wgt. Each
Lbs./kg
2
50
2.375
60.3
2.125
54.0
300
2065
4.19
106
10
1.3
0.6
2 1/2
65
2.875
73.0
2.625
66.7
300
2065
6.19
157
6
3.3
1.5
3
80
3.500
88.9
3.125
79.4
300
2065
6.19
157
6
4.5
2.0
4
100
4.500
114.3
4.125
104.8
300
2065
6.19
157
6
5.8
2.6
5
125
5.563
141.3
5.125
130.2
300
2065
6.19
157
1
7.8
3.5
6
150
6.625
168.3
6.125
155.6
300
2065
6.19
157
1
10.1
4.6
8
200
8.625
219.1
8.125
206.4
300
2065
6.19
157
1
15.0
6.8
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED.
09.07_2
REV_G
09.07
IPS CARBON STEEL PIPE – GROOVED ACCESSORIES
Dielectric Waterway
Series 47
PRODUCT TESTING
Pittsburgh Testing Laboratory Certified Tests and Results:
A test was conducted to determine a Clearflow fitting’s ability to reduce the current flow that causes
internal corrosion in a waterway system.
This current flow exists when dissimilar metals are exposed to an electrolyte (water) and is directly
proportional to the rate at which corrosion occurs. The test fittings were installed between a piece
of copper tubing and galvanized steel pipe. The current flow across these fittings was measured and
recorded by Pittsburgh Testing Laboratory.
After each test sample was assembled, a plastic cap was installed on the copper tubing. Each sample
was filled with 70°F tap water. One lead of the multimeter was connected to the copper tubing.
The other lead was connected to the galvanized pipe. A current reading was taken for each sample.
The results:
Sample #1: (Clearflow Dielectric Waterway Connectors): 0.066 m
Sample #2: (Galvanized Pipe Nipple): 0.345 ma
Sample #3: (Insulated Dielectric Union): 0.441 ma
Sample #4: (Insulated Coupling): 0.209 ma
NOTE: Certified results of these tests are available upon request.
Dielectric Waterway Fittings Test Data and Results:
The facts and test data reported in this submittal have been certified by Pittsburgh Testing Laboratory
and collected by Perfection Corporation engineers in their own laboratories. Similar testing on
Clearflowtype fittings with equal results have been certified by Herron Testing Labs, Inc. For more
complete information, contact Victaulic.
PITTSBURGH TESTING LAB CERTIFIED COMPARATIVE DIELECTRIC FITTING TEST RATINGS*
Corrosion-producing current
measured in milliampere
Direct Current
0.500 Ma
0.450 Ma
0.400 Ma
CO
RROSION
0.350 Ma
CO
0.300 Ma
RROSION
0.250 Ma
0.200 Ma
CO
0.150 Ma
RROSION
0.100 Ma
0.050 Ma
0.000 Ma
CO
RROSION
#1 Clearflow
Dielectric
Waterway
Connector
#2 Plain
Galvanized
Nipple
#3 Insulated
Dielectric
Union
#4 Insulated
Coupling
* The results presented in this graph are specially for ¾" size fittings and Madison, Ohio tap water at 70°F. Other size fittings,
temperatures and water will yield proportional results.
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED.
REV_G
09.07_3
09.07
IPS CARBON STEEL PIPE – GROOVED ACCESSORIES
Dielectric Waterway
Series 47
WARRANTY
Refer to the Warranty section of the current Price List or contact Victaulic for details.
NOTE
This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be
installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the
right to change product specifications, designs and standard equipment without notice and without
incurring obligations.
WARNING
WARNING
• This product must be installed by an experienced, trained installer,
in accordance with the instructions provided with each valve. These
­instructions contain important information.
Failure to follow these instructions may result in serious personal injury,
property damage, or valve leakage.
If you need additional copies of this product literature or the valve
­installation instructions, or if you have any questions about the safe
installation and use of this device, contact Victaulic Company, P.O.
Box 31, Easton, PA 18044-0031 USA, Telephone: 001-610-559-3300.
For complete contact information, visit www.victaulic.com
09.07
1517 REV G
UPDATED 3/2011
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
09.07