BIOLOX® HIP PRODUCT PORTFOLIO
Transcription
BIOLOX® HIP PRODUCT PORTFOLIO
CeramTec Medical Products BIOLOX® HIP PRODUCT PORTFOLIO BIOLOX® Ball Head Portfolio BIOLOX®forte BIOLOX® Ball Head Portfolio BIOLOX®delta 2832364044 22 28 303234 363840 44 12/14 S 12/14 S 12/14 M 12/14 M 12/14 L 12/14 L 12/14 XL BIOLOX®delta Insert Portfolio BIOLOX®delta Inserts XLWzero 28/3628/38 28/40 BIOLOX®delta Insert Portfolio BIOLOX®delta Inserts XLW18 28/35 28/3728/39 30/3830/40 32/3932/4132/4432/4832/52 32/4032/42 32/44 34/4234/44 36/4436/48 36/52 36/4436/4636/4836/5036/5236/54 38/4638/48 40/4840/50 40/5240/54 40/4840/52 BIOLOX® Insert Portfolio BIOLOX®forte Inserts (production only on request) 28/3728/39 28/41 28/44 28/48 BIOLOX®OPTION Portfolio Ball Heads S ML XL 28/52 28 SLEEVES 32/4132/4432/48 32/52 36/4836/52 32 36 40 44 M sleeve size is used on illustrative pictures 48 BIOLOX® Portfolio BIOLOX®delta BIOLOX forte ® Material Combinations BIOLOX®OPTION Portfolio BIOLOX®delta BIOLOX®forte PE/XPE PE/XPE BIOLOX®OPTION ball heads 28 323640 4448 BIOLOX® ball heads and inserts Inserts: BIOLOX®delta Ball heads: BIOLOX®delta from 28/35 to 28/39 from 32/39 to 32/52 from 36/44 to 36/52 28/37, from 28/41 to 28/52 from 32/41 to 32/52 from 36/48 to 36/52 from 40/48 to 40/52 Inserts: BIOLOX®forte (production only on request) Ball heads: BIOLOX®forte only in combination with monoblock inserts only in combination with monoblock inserts Inserts: PE / XPE Inserts: BIOLOX®forte Inserts: BIOLOX®delta Inserts: PE / XPE BIOLOX®OPTION ball heads and sleeves 28 323640 4448 (production only on request) SMLXL BIOLOX® Portfolio BIOLOX®delta BIOLOX®forte BIOLOX®DUO Notice BIOLOX® ball heads must only be used in combination with femoral stems and stem tapers specifically designed for this combination by the implant manufacturer in cooperation with CeramTec and approved/cleared by the authorities. 42 43 44 45 46 47 48 BIOLOX® inserts must only be used in combination with acetabular shells specifically designed for this combination by the implant manufacturer in cooperation with CeramTec and approved /cleared by the authorities. 49 50 28 28 BIOLOX®OPTION ball heads and sleeves must only be used in combination with femoral stems and stem tapers specifically designed for this combination by the implant manufacturer in cooperation with CeramTec and approved / cleared by the authorities. 51 BIOLOX®DUO bipolar cups must only be used in combination with BIOLOX®forte or BIOLOX® delta ball heads specifically designed for this combination by the implant manufacturer in cooperation with CeramTec and approved / cleared by the authorities. 52 53 54 55 56 Important: Please keep in mind that there is no international standard defining the design of the stem taper or their nomenclature. For this reason any reference to stem tapers such as 12/14, 10/12 etc. does not necessarily mean that their design is identical. From the tribological point of view, BIOLOX®forte, BIOLOX® delta, and BIOLOX®OPTION ball heads can be used in combination with BIOLOX®forte or BIOLOX® delta inserts or with polyethylene or crosslinked polyethylene inserts specifically designed and approved/cleared by the authorities for this application. BIOLOX®forte, and BIOLOX® delta inserts may only be used with BIOLOX®forte, BIOLOX® delta, and BIOLOX®OPTION ball heads specifically designed and approved /cleared by the authorities. Other combinations of articulating materials are not permissible. Regulatory guidelines as well as the instructions for use of the implant manufacturers in this regard must always be followed. for Apple® and Android™ tablets and smartphones Scan the QR code to learn more about BIOLOX® high performance ceramics CeramTec GmbH Medical Products Division CeramTec-Platz 1-9 73207 Plochingen Germany Tel. +49 7153 611-828 Fax +49 7153 611-950 E-Mail: medical_products@ceramtec.de Internet: www.biolox.com The information contained in this document was gathered and compiled by medical experts and qualified CeramTec employees to the best of their knowledge. The greatest care was taken to ensure the accuracy and ease of understanding of the information used and presented. CeramTec does not assume any liability, however for the up-to-dateness, accuracy, completeness or quality of the information and excludes any liability for tangible or intangible losses that may be caused by the use of this information. In the event that this document could be construed as an offer at any time, such offer shall not be binding in any event and shall require subsequent confirmation in writing. Please refer to package insert for complete product information, including contraindications, warnings, precautions and adverse effects. Some products and combinations are not approved for use in US or other countries. Please ask your Sales Representative if the products are available in your market. (Review: Sepember 2014) MT130028 · EN · 1000 · 1409 · Loopkomm Infomarketing · Printed in Germany CeraNews App