Krista Morris Wakota Bridge Monitoring and Analysis
Transcription
Krista Morris Wakota Bridge Monitoring and Analysis
Wakota Bridge Monitoring and Analysis Krista Morris Wakota Bridge Monitoring and Analysis Introduction • Project overview • Analysis to date • Future investigation Krista Morris Wakota Bridge Monitoring and Analysis Objectives •Gain a better understanding of the changes in member forces in twin-walled fixed bridge piers due to thermal loading, through the modeling and instrumentation of the Wakota Bridge •Evaluate AASHTO design specifications regarding thermal loading •Verify common design procedures for determining the stiffness of the piers Krista Morris Wakota Bridge Monitoring and Analysis Bridge background • South St. Paul, MN • Across the Mississippi River – 2 bridges, 5 lanes each – 4 spans, 4 piers • Post-tensioned, segmental construction – Cast-in-place, cantilever construction Krista Morris Wakota Bridge Monitoring and Analysis Bridge Background Krista Morris Wakota Bridge Monitoring and Analysis Project Overview • Previous modeling work – Comparing common design methods – Differences between Procedures A and B of AASHTO thermal design in Minnesota – Models developed will be calibrated using field data Krista Morris Wakota Bridge Monitoring and Analysis Instrumentation • Vibrating wire strain gages in both superstructure and piers Krista Morris • Linear string potentiometers in each abutment Wakota Bridge Monitoring and Analysis Instrumentation: Piers • Top Instrumented section Elev. 223.16 ft. (225.1 ft for Pier 4) • • Bottom Instrumented section Elev. 214.00 ft. Krista Morris Instrumented at two elevations (top and bottom of pier wall) Total of 28 gages in Pier 2 Total of 16 gages in Pier 4 Wakota Bridge Monitoring and Analysis Instrumentation: Piers • Oriented vertically to capture axial force • Paired along widths of pier walls to capture bending in both directions Krista Morris Wakota Bridge Monitoring and Analysis Instrumentation: Superstructure String Pot Section P4-6D Krista Morris Section P2-4U Wakota Bridge Monitoring and Analysis Instrumentation: Superstructure = VW Gage 1000 Krista Morris • Spans 3 and 4 instrumented with 40 gages to determine “locked in forces” due to temperature changes • Oriented horizontally to capture axial forces • Linear string potentiometer at each abutment to measure overall expansion and contraction Wakota Bridge Monitoring and Analysis Data: Strain change Strain vs. Time Gage 2TDR1, Pier 2 100 50 0 -5011/18 -100 -150 -200 -250 -300 -350 -400 1/7 2/26 4/17 500 6/6 7/26 9/14 Date Strain (microstrain) Strain (microstrain) Strain vs. Time Gage 2TUR1, Pier 2 400 300 200 100 0 11/18 -100 1/7 100 80 60 40 20 0 11/18 1/7 2/26 4/17 Date Krista Morris 6/6 4/17 Date 6/6 7/26 9/14 Temperature vs. Time Gage 2TDR1, Pier 2 7/26 9/14 Temperature (degrees F) Temperature (degrees F) Temperature vs. Time Gage 2TUR1, Pier 2 2/26 100 80 60 40 20 0 11/18 1/7 2/26 4/17 Date 6/6 7/26 9/14 Wakota Bridge Monitoring and Analysis Data: Strain change 100 50 0 -50 0 -100 -150 -200 -250 -300 -350 -400 Strain vs. Temperature Gage 2TDR1, Pier 2 500 20 Krista Morris 40 60 Temperature (degrees F) 80 100 Strain (microstrain) Strain (microstrain) Strain vs. Temperature Gage 2TUR1, Pier 2 400 300 200 100 0 -100 0 20 40 60 Temperature (degrees F) 80 100 Wakota Bridge Monitoring and Analysis Data Daily temperature and strain fluctuation Strain at 4:00 PM Top of Pier 4 3750 3350 3150 Up - Left 2950 30 25 20 Up - Left 15 Up - Right 10 Down - Left 5 Down - Right 0 1/7 1/12 1/17 1/22 1/27 2/1 Air Temperature, 1/10 - 2/9 Down - Left 2550 Down - Right 2350 2150 1/9 1/13 1/17 1/21 1/25 1/29 2/2 Date Krista Morris 2/6 2/10 2/14 2/6 2/11 2/16 Date Up - Right 2750 Temperature (degrees F) Strain (microstrain) 3550 Temperature (degrees F) Temperature at 4:00 PM Top of Pier 4 30 20 10 0 1/9 -10 1/19 1/29 Date 2/8 Wakota Bridge Monitoring and Analysis Cross-section Modeling 10 00 z 10 00 Krista Morris Wakota Bridge Monitoring and Analysis Analysis • Linear interpolation of values at gages to find stress distribution along sections – Integrated across area of each subdivision area to find forces, sum of forces from each Krista Morris Wakota Bridge Monitoring and Analysis Results – Through June 14 – 84 degree F temperature range 600 500 Force (kips) • Force at Pier 2 cross-sections Avg. Temperature vs. Axial force at 732.15 ft 400 300 200 100 0 -100 0 20 40 60 Temperature (degrees F) 80 100 Avg. Temperature vs. Axial Forces at 702.1 ft 800 Force (kips) 600 400 200 0 -200 Krista Morris 0 20 40 60 Temperature (degrees F) 80 100 Wakota Bridge Monitoring and Analysis Results – Through June 14 – 82 degree F temperature range 500 400 Force (kips) • Force at Pier 4 cross-sections Avg. Temperature vs. Axial load at 738.5 ft 300 200 100 0 -100 0 10 -200 20 30 40 50 60 70 60 70 Temperature (degrees F) Avg. Temperature vs. Axial load at 702.1 ft 40 Force (kips) 30 20 10 0 -10 0 -20 Krista Morris 10 20 30 40 50 Temperature (degrees F) Wakota Bridge Monitoring and Analysis Conclusions • Significant differences in axial forces calculated for AASHTO Procedures A and B – Significant changes in temperatures • Analyses can be designed to simulate changes in stiffness of piers • Direct change in strain and internal forces due to temperature Krista Morris Wakota Bridge Monitoring and Analysis Future work • Analysis of axial forces and moments on piers will continue – More complex cross-sections – Additional six months of field data – Calibration of models using field data – Additional analytical studies Krista Morris Wakota Bridge Monitoring and Analysis Thank you! Questions? Krista Morris