process catalogue 2013/2014

Transcription

process catalogue 2013/2014
PROCESS
CATALOGUE
2013/2014
INDex
INDUSTRIAL automation
INDUSTRIAL controllers
km1
kx1
kr1
r38
tlk41
tlk42
tlk43
tlk72
tlk96
tlk94
c1
m1
m2
m3
m4
x1
x3
q1
q3
advanced programmer controllers
km3
KX3
KR3
k31
k32
k38
k39
k48
k49
k85
k30
m5
x5
q5
din rail mounting controllers
d1
d2
d3
k30
k85
11
13
16
18
20
22
24
24
24
26
28
30
32
34
36
38
38
40
40
42
42
45
48
50
52
54
54
54
54
56
56
58
60
62
64
64
67
70
70
70
72
74
tlz35
Thermostats - analogue controllers
Z31A
TLZ35
e51a
w09
tcpde
special controllers and “custom”
TCO30
tlk33
pac systems
m81
mp02
mp-d1
mp-d2
mp-d4
cu02
openpcs
pre-programmed systems
clima pac
brewery pac
light pac
operator panells
p04
opMT
p01
p30
p32
timer - counters - power limiters
BWt40
tt34
tt49
tt73
tc34
tc49
tc73
tp34
tp49
indicators
tli40
k31v
k38v
76
79
82
84
86
88
90
93
96
98
101
104
106
108
108
108
110
112
115
116
118
120
123
126
128
132
132
132
135
138
140
140
140
142
142
142
144
144
147
150
152
152
k48v
k85v
J1 / j3
j5
ACQUISItion and data recording
i/o modules
d7
d8
d9
ANALOGue i/o
digital i/o
TDA
supervision
autolink
DX
dy
emission ANALySIs and combustion CONTROL
analysis systems
zo2
oxi
oxm
oxr
zco
ACCESSORIes
accessories
a01
a30
APS2 ALDR
APS2 Atopeh
aps2 modem
BOX-AR
CAL
GUAR
TAPPO
TCTR
tlcov
TR-AMP
ZOC
Thermoelements
154
154
156
158
161
163
166
166
166
168
170
174
177
180
182
182
185
187
188
190
190
190
192
195
197
198
200
202
202
202
203
203
203
204
204
204
205
205
206
company profile
Ascon Tecnologic is an Italian company that develops, manufactures and commercializes a complete
range of products for the regulation and automation of machinery and systems in the manufacturing
and processing sectors as well as that of industrial and commercial refrigeration.
The group Ascon Tecnologic has more than 200 employees and, in its productive plants, realizes every
year over a million of instruments.
Ascon Tecnologic operates in over 50 countries with 6 branches, its own agents and a distribution
network, offering clients sales and after-sales assistance.
Manufacturing unit, Manaus (Brazil).
Headquarters, offices, R&D, Manufacturing unit, Vigevano (Italy).
quality certification /
safety and APPROVALS
Ascon Tecnologic S.r.l. has obtained the certification of “Quality System” in conformity to UNI EN ISO
9001:2008 released by the corporate certifier Det Norske Veritas Italy S.r.l.
The instruments are developped for the use in conformity to the actual compliance, as concern the CE
mark according to Directives 2006/95/CE (Low Voltage) and 2004/108/CE (EMC).
The applicable rules, according to the model, are:
Safety
- EN61010-1
- EN60730-1
- UL873 for use conforming as foreseen by Underwriters Laboratory Inc. (only for approved
instruments).
EMC
EN61326-1
Remarks: please make reference to the documentation and the individual certifications for details of
the applicable norms.
industrial
AUTOMAtion
Flexible
control
10
11
INDUSTRIAL controllers
Evolution...cubed !
Experience and innovation are at the base of this range of products, able to answer to any
demand of performances.
From the “entry level” controller with innovative “Sensitive-Touch” keyboard to the more
sophisticated microprocessor based controllers with PID algorithm, in different sizes, standard
and not.
New KUBE line: more and more in less space!
Pocket size, energy saving functions and advanced features.
12
13
INDUSTRIAL controllers
Control
·
·
·
TLK72
TLK96
TLK94
C1
M1
M2
M3
M4
·
·
·
·
X1
X3
·
·
Q1
Q3
·
·
·
4
4
4
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
2
2
2
4
4
4
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
4
·
4
·
4
·
·
·
·
·
2
4
4
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
1
·
4
2
·
4
4
·
·
·
·
·
·
·
·
3
2
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
4
4
4
·
4
·
4
·
4
·
4
·
4
·
4
·
4
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
3
1
·
·
4
1
·
·
3
·
4
1
·
·
4
1
·
·
1
·
4
1
·
·
3
1
·
·
1
·
3
·
3
·
4
1
·
SPECIAL
CONTROLLERS
AND “CUSTOM”
·
PAC SYSTEMS
·
THERMOSTATS
ANALOGUE
CONTROLLERS
·
·
2
·
5
2
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
4
1
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
RS485
Timer on board
Programmer
CE certification
UL approval
ENEC approval
TLK43
·
4
12 Vac/Vdc
24 Vac/Vdc
100… 240 Vac
ON/OFF and PID
Servomotor control
TLK42
·
·
Universal input
PTC-NTC
J-K
S
S-R-T
Pt100
∆T PT100
Pt1000
IR sensors
Digital
For CT
TLK41
·
·
·
Relay or voltage for SSR drive outputs
Analogue current or voltage outputs
Measuring or Set Point retransmission
Power supply
R38
·
PREPROGRAMMED
SYSTEMS
Input
KR1
·
PLC AND
OPERATOR
PANELS
3 dynamic colour dual LED display
Single display
Dual display
Digit
"Sensitive Touch" keyboard
KX1
TIMERS
COUNTERS
POWER LIMITERS
Dimensions (mm)
KM1
78 x 35
24 x 48
48 x 48
48 x 96
72 x 72
96 x 96
INDICATORS
features
DIN RAIL
MOUNTING
CONTROLLERS
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
14
15
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
Up to 4
OUT 1: Relay SPST-NO 4A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10%
OUT 2: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10%
OUT 3: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 110.5V min. @ 15mA ±10%
OUT 4 programmable: voltage output to drive SSR 13V max. @ 1mA, 10.5V min. @ 22mA ±10%
or transmitter supply or 2nd digital input
FUNCTIONAL
Control
24 Vac/Vdc ± 10%, 100… 240 Vac/Vdc -15%/+ 10% (50/60 Hz)
7 VA max.
48 x 48 mm (1/16DIN) - depth 63 mm / 125 g
Flush in panel in 45 x 45 mm hole
16 screw terminals 2.5 mm² (AWG22…. AWG14) fix, plug-in or clamp type
IP 65, mounted on panel with gasket
0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F)
20… 95 RH%, without condensation
EN 61010-1, EN 61326
DIN RAIL
MOUNTING
CONTROLLERS
Close
Line 100... 240 VAC/
20... 30 VDC
Neutral
12 VDC
(note)
Transducer
mV, V
mA
Thermocouple
TERMINALS
12 VDC
(note)
L
Stripped wire
L 5.5 mm - 0.21 in.
Pin connector:
1.4 mm - 0.055 in. max.
q
PV
Note: Terminal 4 can be programmed as:
- Digital Input (DI2) connecting a free of voltage
contact between terminals 4 and 16
- 0... 12 V SSR Drive Output (OP4) connecting the load
between terminals 4 and 16
- 12 Vdc (20 mA) transmitter power supply
connecting the transmitter between terminals 4 and 1
Transducer
Pt1000/NTC/PTC
Pt100
R
O
dimensions
km1
R
O
-
48
SPECIAL
CONTROLLERS
AND “CUSTOM”
PV
THERMOSTATS
ANALOGUE
CONTROLLERS
OP3 *
11
14
48
D
S
E
N
M
-
Terminals
18
10
15
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
Alarms
Set Point
Serial communication
Baud rate
Working hours counters
Wattmeter function
EVOogreen
Timer (optional)
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
PID single or double action, ON/OFF, ON/OFF with Neutral Zone
Autotuning and Selftuning algorithms, Overshoot control
3 alarms programmable as absolute, deviation, band
4 programmable Set Points
TTL (standard) + RS485 (optional), ModBus RTU protocol
1200… 38400 baud
A cumulative non-erasable counter and a second one resettable with alarm
Instantaneous power, time consumption
Stand-by mode of display, selectable
Independent with 5 function modes
OP4
(note)
Analogue input
2 wires
Passive 4... 20 mA
R
O
-
Open
DI2 (note)
3 wires
C
E
OP2 *
PAC SYSTEMS
OUTPUTS
L
H
DI1
OP1
RS485
T
PLC AND
OPERATOR
PANELS
Digital inputs
Code
TIMERS
COUNTERS
POWER LIMITERS
Accuracy
KM1
Version
Controller
Controller + Timer
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC, RTD, mA, V, mV/digital input 1
TC, NTC, PTC, mA, V, mV/digital input 1
OUT 1
Relay SPST 4A
Vdc for SSR driving
OUT 2
Relay SPST 2A
Vdc for SSR driving
Not available
OUT 3
Relay SPST 2A
Vdc for SSR driving
Not available
IN/OUT 4
Digital input 2 or digital output or transmitter supply
RS485
Available
Not available
connection
Plug-in screw type
Plug-in screw type, fix part only
Clamp type
Fix screw type (standard)
INDICATORS
Universal
Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F),
S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F)
Infrared sensors: J or K
Thermoresistances: 3 wires Pt 100 and 2 wires Pt 1000 (-200... 850°C/-328... 1562°F)
Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V
Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F),
S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F)
Infrared sensors: J or K
Thermistors: PTC KTY81-121 (-55... +150°C/-67... 302°F), NTC 103 AT2 (-50... +110°C/-58... 230°F)
Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V
± 0.5% span ±1 digit, (±1% span ±1 digit for T/c S type)
1 or 2 according to instrument’s part number
(the 2nd digital input is alternative to OUT 4)
km1
To compose the part number, pls. choose one of the option for each variable
I/O MODULES
INPUTS
COnnections
14
Dual LED
KM1
Main display: 4 digit h 15.5 mm. 3 colours: red, green and amber
Secondary display: 4 green digit, h 7 mm
48
DISPLAY
PREPROGRAMMED
SYSTEMS
how to order
features
45
•3 dynamic colour led display
•Independent Timer
•WORKING hours counter
•Wattmeter function
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
km1
16
17
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
OUTPUTS
Up to 4
OUT 1: Relay SPST-NO 4A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10%
OUT 2: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10%
OUT 3: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 110.5V min. @ 15mA ±10%
OUT 4 programmable: voltage output to drive SSR 13V max. @ 1mA, 10.5V min. @ 22mA ±10%
or transmitter supply or 2nd digital input
FUNCTIONAL
Control
24 Vac/Vdc ± 10%, 100… 240 Vac/Vdc -15%/+ 10% (50/60 Hz)
7 VA max.
48 x 96 mm (1/8 DIN) - depth 76 mm / 260 g
Flush in panel in 45 x 93 mm hole
16 screw terminals 2.5 mm² (AWG22…. AWG14) fix, plug-in or clamp type
IP 65, mounted on panel with gasket
0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F)
20… 95 RH%, without condensation
EN 61010-1, EN 61326
L
H
OP3 *
C
NO
Open
OP2 *
C
NA
RS485
Analogue input
C
E
OP1
C
KX3 only
DI1
Pt1000/NTC/PTC
Pt100
DI2
(note)
Passive 4... 20 mA
3 wires
12 Vdc (note)
R
O
R
O
-
DIN RAIL
MOUNTING
CONTROLLERS
NO
Close
THERMOSTATS
ANALOGUE
CONTROLLERS
q
Note: Terminal 4 can be programmed as:
- Digital Input (DI2) connecting a free of voltage
contact between terminals 4 and 5
- 0... 12 V SSR Drive Output (OP4) connecting
the load between terminals 4 and 5
- 12 Vdc (20 mA) transmitter power supply
connecting the transmitter between
terminals 4 and 1
SPECIAL
CONTROLLERS
AND “CUSTOM”
T
100... 240 Vac/ Fase
20... 30 Vdc
Neutral
L
Stripped wire
L 5.5 mm - 0.21 in.
Pin connector:
1.4 mm - 0.055 in. max.
Transducer
OP4
(note)
2 wires
PV
PV
Transducer
12 Vdc
(note)
mV, V
mA
Thermocouple
DIMENSIONS
kx1
R
O
-
48
11
62
14
18
D
S
E
N
M
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
Alarms
Set Point
Serial communication
Baud rate
Working hours counters
Wattmeter function
EVOogreen
Timer (optional)
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
PID single or double action, ON/OFF, ON/OFF with Neutral Zone
Autotuning and Selftuning algorithms, Overshoot control
3 alarms programmable as absolute, deviation, band
4 programmable Set Points
TTL (standard) + RS485 (optional), ModBus RTU protocol
1200… 38400 baud
A cumulative non-erasable counter and a second one resettable with alarm
Instantaneous power, time consumption
Stand-by mode of display, selectable
Independent with 5 function modes
TERMINALS
PAC SYSTEMS
Digital inputs
Code
PLC AND
OPERATOR
PANELS
Accuracy
KX1
Version
Controller
Controller + Timer
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC, RTD, mA, V, mV/digital input 1
TC, NTC, PTC, mA, V, mV/digital input 1
OUT 1
Relay SPST 4A
Vdc for SSR driving
OUT 2
Relay SPST 2A
Vdc for SSR driving
Not available
OUT 3
Relay SPST 2A
Vdc for SSR driving
Not available
IN/OUT 4
Digital input 2 or digital output or transmitter supply
RS485
Available
Not available
connection
Plug-in screw type
Plug-in screw type, fix part only
Clamp type
Fix screw type (standard)
TIMERS
COUNTERS
POWER LIMITERS
Universal
Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F),
S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F)
Infrared sensors: J or K
Thermoresistances: 3 wires Pt 100 and 2 wires Pt 1000 (-200... 850°C/-328... 1562°F)
Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V
Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F),
S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F)
Infrared sensors: J or K
Thermistors: PTC KTY81-121 (-55... +150°C/-67... 302°F), NTC 103 AT2 (-50... +110°C/-58... 230°F)
Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V
± 0.5% span ±1 digit, (±1% span ±1 digit for T/c S type)
1 or 2 according to instrument’s part number
(the 2nd digital input is alternative to OUT 4)
kx1
To compose the part number, pls. choose one of the option for each variable
INDICATORS
INPUTS
CONNECTIONS
I/O MODULES
Dual LED
KX1
Main display: 4 digit h 15.5 mm. 3 colours: red, green and amber
Secondary display: 4 green digit, h 10 mm + 20 segments Bargraph
96
DISPLAY
PREPROGRAMMED
SYSTEMS
HOW TO ORDER
features
89
•3 dynamic colour led display
•Independent Timer
•WORKING hours counter
•Wattmeter function
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
kx1
18
19
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
Up to 4
OUT 1: Relay SPDT-NO 4A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10%
OUT 2: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10%
OUT 3: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 110.5V min. @ 15mA ±10%
OUT 4 programmable: voltage output to drive SSR 13V max. @ 1mA, 10.5V min. @ 22mA ±10%
or transmitter supply or 2nd digital input
FUNCTIONAL
Control
24 Vac/Vdc ± 10%, 100… 240 Vac/Vdc -15%/+ 10% (50/60 Hz)
7 VA max.
72 x 33 mm - depth 78 mm + 14 mm (plug-in terminals) / 200 g
Flush in panel in 69 x 28 mm hole
16 screw terminals 2.5 mm² (AWG22…. AWG14) fix, plug-in or clamp type
IP 65, mounted on panel with gasket
0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F)
20… 95 RH%, without condensation
EN 61010-1, EN 61326
mV, V
12Vdc
(note)
mA
Pt1000/NTC/PTC
DI2
(note)
Thermocouple
Pt100
OP1
OP2 *
TERMINALS
L
Pin connector:
Stripped wire
1.4 mm - 0.055 in. max. L 5.5 mm - 0.21 in.
q
Neutral Line C NO
100... 240VAC/
Close
20... 30VDC
C
NO
C
NC NO
Open
Note: Terminal 4 can be programmed as:
- Digital Input (DI2) connecting a free of voltage contact between terminals 4 and 11
- 0... 12 V SSR Drive Output (OP4) connecting the load between terminals 4 and 11
- 12 Vdc (20 mA) transmitter power supply connecting the transmitter between terminals 4 and 1
R
O
R
O
-
DI1
OP4
(note)
OP3 *
C
E
THERMOSTATS
ANALOGUE
CONTROLLERS
2Vdc
(note)
L
H
RS485
Transmitter
2 wires
SPECIAL
CONTROLLERS
AND “CUSTOM”
3 wires
DIMENSIONS
kR1
R
O
D
78
S
-
5
64
14
18
E
N
M
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
Alarms
Set Point
Serial communication
Baud rate
Working hours counters
Wattmeter function
EVOogreen
Timer (optional)
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
PID single or double action, ON/OFF, ON/OFF with Neutral Zone
Autotuning and Selftuning algorithms, Overshoot control
3 alarms programmable as absolute, deviation, band
4 programmable Set Points
TTL (standard) + RS485 (optional), ModBus RTU protocol
1200… 38400 baud
A cumulative non-erasable counter and a second one resettable with alarm
Instantaneous power, time consumption
Stand-by mode of display, selectable
Independent with 5 function modes
T
Passive 4... 20 mA PV
PV
PAC SYSTEMS
OUTPUTS
Analogue input
Transmitter
PREPROGRAMMED
SYSTEMS
Digital inputs
CODE
PLC AND
OPERATOR
PANELS
Accuracy
KR1
Version
Controller
Controller + Timer
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC, RTD, mA, V, mV/digital input 1
TC, NTC, PTC, mA, V, mV/digital input 1
OUT 1
Relay SPDT 4A
Vdc for SSR driving
OUT 2
Relay SPST 2A
Vdc for SSR driving
Not available
OUT 3
Relay SPST 2A
Vdc for SSR driving
Not available
OUT 4
Digital input 2 or digital output or transmitter supply
RS485
Available
Not available
connection
Plug-in screw type
Plug-in screw type, fix part only
Clamp type
Fix screw type (standard)
TIMERS
COUNTERS
POWER LIMITERS
Universal
Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F),
S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F)
Infrared sensors: J or K
Thermoresistances: 3 wires Pt 100 and 2 wires Pt 1000 (-200... 850°C/-328... 1562°F)
Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V
Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F),
S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F)
Infrared sensors: J or K
Thermistors: PTC KTY81-121 (-55... +150°C/-67... 302°F), NTC 103 AT2 (-50... +110°C/-58... 230°F)
Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V
± 0.5% span ±1 digit, (±1% span ±1 digit for T/c S type)
1 or 2 according to instrument’s part number
(the 2nd digital input is alternative to OUT 4)
kr1
To compose the part number, pls. choose one of the option for each variable
INDICATORS
INPUTS
CONNECTIONS
I/O MODULES
Dual LED
KR1
Main display: 4 digit h 11.7 mm. 3 colours: red, green and amber
Secondary display: 4 green digit, h 7 mm
35
DISPLAY
DIN RAIL
MOUNTING
CONTROLLERS
HOW TO ORDER
features
28
•3 dynamic colour led display
•Independent Timer
•WORKING hours counter
•Wattmeter function
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
kr1
20
21
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
INDUSTRIAL
CONTROLLERS
r38
S
-
F
L
H
C
1
+
NC
NO
2
3
O UT2
C
4
DIN RAIL
MOUNTING
CONTROLLERS
+
NC
NO
5
IN PUTS
6
O UT1
7
8
10 11 12
SU PPLY
F
A
T
THERMOSTATS
ANALOGUE
CONTROLLERS
RELAYS: 8A-AC 1 (6A-AC 3) / 250VAC
SSR : 10 V DC/ 20 mA
PTC -NTC
Pt100/ Pt 1000
+
tc
R
O
-
PAC SYSTEMS
R
O
DIMENSIONS
r38
B
78
E
N
-
6
12.2
78
(*) Capacitive Touch screen keyboard
64
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
PREPROGRAMMED
SYSTEMS
12 Vac/Vdc, 24 Vac, 100… 240 Vac/Vdc ±10% (50/60 Hz)
6 VA approx.
78 x 35 mm - depth 64 mm / 180 g approx.
Mechanical or “Sensitive Touch”
Screw terminal block 2 x 1 mm² plug-in connector or fix type
Flush in panel in 71 x 29 mm hole
IP 65, mounted on panel with gasket
0... +50°C (32... 122°F) / -30... +70°C (-22... +158°F)
20… 85 RH%, without condensation
Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1)
CODE
PLC AND
OPERATOR
PANELS
ON/OFF single and double action, Neutral Zone, PID, programmable
Autotuning
1 sec
TTL ModBus
9600 baud
R38
keyboard
Mechanical
Sensitive-Touch (*)
Power supply
12 Vac/Vdc
24 Vac/Vdc
100… 240 Vac/Vdc
INPUT
TC (J,K)
PT100 (2 wires only)
PTC/NTC/PT1000
OUT 1
Relay SPDT 8A-AC1
Vdc for SSR driving
OUT 2
Relay SPDT 8A-AC1
Vdc for SSR driving
Not available
Buzzer (internal)
Available
Tipo Collegamento
Plug-in screw type
Plug-in screw type, fix part only
Fix screw type (standard)
TIMERS
COUNTERS
POWER LIMITERS
OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or voltage to drive SSR 20mA/12 Vdc ±20% 20 mA max.
12 Vdc/20 mA max.
R38
To compose the part number, pls. choose one of the option for each variable
35
Accuracy
OUTPUTS
Up to 2
Auxiliary power supply
FUNCTIONAL
Control
PID functions
Sampling rate
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Keyboard
Connections
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
Thermocouples J, K (-40... +999°C / -40… +999°F) or Infrared sensors: J or K
Thermoresistances Pt 100 2 wires (-50.0... +850°C / -58... +999°F) autoranging
Thermoresistances Pt 1000 2 wires (-50.0... +850°C / -58... +999°F) autoranging +
Thermistors PTC KTY 81-121 (990Ω at 25°C) (-50.0... +150°C / -58.0 a 302°F ) autoranging e
Thermistors NTC 103AT-2 (10kΩ at 25°C) (-50.0... +109°C / -58.0... +228°F )
± 0.5% span ±1 digit@ 25°C
CONNECTIONS
28
3 different configurations
R38
4 red or blue digit, h 12 mm
35
DISPLAY
Single
INPUTS
SPECIAL
CONTROLLERS
AND “CUSTOM”
HOW TO ORDER
features
ADVANCED
PROGRAMMER
CONTROLLERS
•“Sensitive Touch” keyboard
•easy programming
22
23
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
Accuracy
Current transformer (CT) input
Digital input
OUTPUTS
Up to 4
Auxiliary power supply
Current (as alternative to Relay output)
Voltage (as alternative to Relay output)
FUNCTIONAL
Control
PID functions
Multi Set Point
Servomotor control
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
Thermoresistances: Pt100 and Pt1000
Thermoresistances: Pt100 3 wires (-200... +850°C/-328... +1562°F
3 wires
or -199.9... +850.0°C/-199.9... +999.9°F) (see table next page for
according to EN 60751/A2, classe A or B
temperature ranges)
Thermistors PTC KTY 81-121 (990 kΩ at 25°C) (-55... +150°C/-67... +302°F
or -55.0... +150.0°C -67.0... +302.0°F) and NTC 103AT-2 (10Ω at 25°C)
(-50... +110°C/-58... +230°F or -50.0... +110.0°C/-58.0... +230.0°F)
Linear signals: 0/10... 50 mV, 0/12... 60 mV, 0/4... 20 mA, 0/1... 5 V, 0/2... 10 V
±0.15% fs
CT 50 mA max.
-optoisolated
OUT 1: Relay SPST-NO (5 A-AC1, 2 A-AC3/250 Vac) or 7 mA/14 Vdc 20 mA max. to drive SSR
OUT 2, OUT 3 and OUT 4: Relay SPST-NO (3 A-AC1, 1,5 A-AC3/250 Vac) or 7 mA/14 Vdc 20 mA max. to drive SSR
12 Vdc/20 mA max.
OUT 1 and OUT 2: 0/4… 20 mA.
-OUT 1 and OUT 2: 0/2… 10 V
ON/OFF, Neutral Zone, PID single and double action
AUTOTUNING, FAST TUNING, Selftuning
Up to 4 pre-programmable Set Point
-3 points
-On analogue output
RS485 with ModBus-RTU (JBUS) protocol
-1200… 38400 baud, programmable
24 Vac/Vdc, 100… 240 Vac/Vdc ±10% (50/60 Hz)
10 VA approx.
48 x 48 mm (1/16DIN) - depth 98 mm / 190 g approx.
Flush in panel in 45 x 45 mm hole
Screw terminal block 2 x 1 mm²
IP 65, mounted on panel with gasket
0… +50°C (32… +122°F) /-25… +60°C (-13… +140°F)
30… 95 RH% without condensation
Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1)
ANALOG. (TLK43)
TC
+1
PTC
-
+
+
+
7
8
NO
C
OUT4 OUT3
+
+
-
NO NO
9 10 11 12
-
+
NO
C
13 14 15 16 17 18
GND B
SUPPLY
DIG. IN (TLK43)
A
RS485
4..20 mA
PASSIVE
(2 wires)
+
-
0/4..20 mA
ACTIVE
0..50/60 mV
0/1..5 V
0/2..10 V
tlk43 temperature ranges
INPUT
tc K
tc B
tc E
tc L
tc N
tc R
tc T
tc C
Pt100 (IEC)
Out3 Out4
6
C
OUT1
G
TEMPERATURE RANGES
Pt1000 (IEC)
The dimensions are expressed in mm
24
I
Ingrared sensors (ZIS)
98
5
-
+ -
4..20 mA
ACTIVE
+
-
tc S
44.5
48
SET
+
OUT 12 VDC
(Max 20 mA)
-
S
I
-
AT
ST
=
4
TA HB
PTC (KTY81-121)
-
3
NTC
tc J
TLK41 / tlk42 / tlk43
Out1 Out2
-
OUT2
+
G
Pt100
R
O
-
DIMENSIONS
9.5
2
ext.
gen.+
Notes:
TLK41-TLK42-TLK43: OUT 3 and OUT 4 have to be of the same type (both R or O).
CT INPUT: this function has to be always associated to an output (R or O).
TLK43: Analogue output and CT function are mutually exlcusive.
Digital input is always available when RS485 option is provided.
RS485 and OUT 4 are mutally exclusive.
48
RELAY
INPUT
R
O
C
V
-
H
-
-
SSR
R
O
C
V
R
O
-
DIN RAIL
MOUNTING
CONTROLLERS
-
L
H
NTC (103-AT2)
THERMOSTATS
ANALOGUE
CONTROLLERS
ANALOG.: 0/4 ..20 mA - 0/2..10 V SSR: 7mA/14VDC
RELAY OUT1: 5A-AC1 (2A-AC3) 250VAC
RELAYS OUT2,3,4: 3A-AC1 (1A-AC3) 250VAC
SPECIAL
CONTROLLERS
AND “CUSTOM”
Universal
Thermocouples: J, K, S, B, C, E, L, N, R, T
(see table next page for
temperature ranges)
CODE
without D.P.
-160 ... 1000 °C
- 256 ... 1832 °F
-100 ... 1370 °C
- 148 ... 2498 °F
0 ... 1760 °C
32 ... 3200 °F
72 ... 1820 °C
162 ... 3308 °F
-150 ... 750 °C
-252 ... 1382 °F
-150 ... 900 °C
-252 ... 1652 °F
-250 ... 1300 °C
-418 ... 2372 °F
-50 ... 1760 °C
-58 ... 3200 °F
-250 ... 400 °C
-418 ... 752 °F
0 ... 2320 °C
32 ... 4208 °F
-46 ... 785 °C
-50 ... 1445 °F
-200 ... 500 °C
-328 ... 932 °F
-200 ... 850 °C
-328 ... 1562 °F
-55 ... 150 °C
-67 ... 302 °F
-50 ... 110 °C
-58 ... 230 °F
with D.P.
-160.0 ... 999.9 °C
-199.9 ... 999.9 °F
-100.0 ... 999.9 °C
-148.0 ... 999.9 °F
0.0 ... 999.9 °C
32.0 ... 999.9 °F
72.0 ... 999.9 °C
162.0 ... 999.9 °F
-150.0 ... 750.0 °C
-199.9 ... 999.9 °F
-150.0 ... 900.0 °C
-199.9 ... 999.9 °F
-199.9 ... 999.9 °C
-199.9 ... 999.9 °F
-50.0 ... 999.9 °C
-58.0 ... 999.9 °F
-199.9 ... 400.0 °C
-199.9 ... 752.0 °F
0.0 ... 999.9 °C
32.0 ... 999.9 °F
-46.0 ... 785.0 °C
-50.8 ... 999.9 °F
-199.9 ... 500.0 °C
-199.9 ... 932.0 °F
-199.9 ... 850.0 °C
-199.9 ... 999.9 °F
-55.0 ... 150.0 °C
-67.0 ...302.0 °F
-50.0 ... 110.0 °C
-58.0 ... 230.0 °F
PAC SYSTEMS
Thermocouples: J (-160... +1000°C/-256... +1832°F
or -160.0... +999.9°C/-199.9... +999.9°F ),
K (-100... +1370°C/- 148... +2498°F
or -100.0... +999.9°C/-148.0... +999.9°F),
S (0... +1760°C/32... +3200°F
or 0.0... 999.9°C/32.0... +999.9°F)
Infrared sensors: J or K
TLK41 / TLK42 / TLK43
Power supply
24 Vac/Vdc
100... 240 Vac
OUT 1
Relay
Voltage for SSR driving
0/4... 20mA (TLK43 only)
0/2... 10V (TLK43 only)
OUT 2
Relay
Voltage for SSR driving
0/4... 20mA (TLK43 only)
0/2... 10V (TLK43 only)
Not available
OUT 3
Relay
Voltage for SSR driving
Not available
OUT 4
Relay
Voltage for SSR driving
Not available
serial communication and digital INPUT
RS485
RS485 and digital input (TLK43 only)
Not available
current transformer INPUT
Available
Not available
PREPROGRAMMED
SYSTEMS
INPUTS
TLK41 / tlk42 / tlk43
To compose the part number, pls. choose one of the option for each variable
PLC AND
OPERATOR
PANELS
Dual display: 4 red and green digit, h 7mm
CONNECTIONS
TIMERS
COUNTERS
POWER LIMITERS
TLK43
INDICATORS
TLK42
I/O MODULES
Display
TLK41
Single display: 4 red digit,
h 12 mm
SUPERVISION
DISPLAY
COMBUSTION
CONTROL
HOW TO ORDER
features
ACCESSORIES
•UNIVERSAL INPUT
•RS485
•UP TO 4 OUTPUTS
•CT INPUT
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
tlk 41/42/43
25
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
INDUSTRIAL
CONTROLLERS
tlk72
24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz)
10 VA approx.
72 x 72 mm - depth 97 mm / 325 g approx.
Flush in panel in 67 x 67 mm hole
Screw terminal block 2 x 1 mm²
IP 54, mounted on panel with gasket
0… +50°C (+32… +122°F) / -10... +60°C (+14… +140°F)
30… 95 RH% without condensation
Directive CEE EMC 89/336 (EN 61326), Directive CEE BT 73/23 and 93/68 (EN 61010-1)
DIN RAIL
MOUNTING
CONTROLLERS
THERMOSTATS
ANALOGUE
CONTROLLERS
SPECIAL
CONTROLLERS
AND “CUSTOM”
C
E
I
V
R
O
R
O
R
O
-
DIMENSIONS
tlk72
S
I
-
PAC SYSTEMS
ON/OFF, Neutral Zone, PID
AUTOTUNING, FAST TUNING, Selftuning
Up to 4 pre-programmable Set Point
RS485 with ModBus-RTU (JBUS) protocol
1200… 38400 baud, programmable
L
H
PREPROGRAMMED
SYSTEMS
Auxiliary power supply
FUNCTIONAL
Control
PID functions
Multi Set Point
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1 : Relay SPDT (8 A-AC1, 3 A-AC3 / 250 V AC) or voltage to drive SSR 8Vdc/8 mA
OUT 2 e OUT 3: Relay SPST-NO (8 A-AC1 3A-AC3/250 Vac) or voltage to drive SSR 8Vdc/8 mA
12 Vdc/20 mA max.
TLK72
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC (J,K,S,IRS)+PT100,mV
TC (J,K,S,IRS)+PTC,NTC,mV
0/4… 20mA
0/1… 5V, 0/2… 10V
OUT 1
Relay
Voltage for SSR driving
OUT 2
Relay
Voltage for SSR driving
Not available
OUT 3
Relay
Voltage for SSR driving
Not available
serial communication
RS485
Not available
digital INPUT
Available
Not available
8
72
9
AT
ST
SET
Out1 Out2
- =
PLC AND
OPERATOR
PANELS
Up to 3
TLK72
To compose the part number, pls. choose one of the option for each variable
55
Accuracy
OUTPUTS
Thermocouples J (0... 1000 °C/ 32… 1832°F), K (0… 1370°C/32… 2498°F), S (0… 1760°C/32… 3200°F) and
Infrared sensors J or K + Thermoresistances Pt 100 3 wires (-200... 850 °C/-328... 1562 °F) +
Linear signals 0/10… 50mV, 0/12… 60mV
Thermocouples J (0... 1000 °C/ 32… 1832°F), K (0… 1370°C/32… 2498°F), S (0… 1760°C/32… 3200°F) and
Infrared sensors J or K + Thermistors PTC KTY 81-121 (990Ω at 25°C) (-55... 150 °C/-67... 302 °F) and
Thermistors NTC 103AT-2 (10 kΩ at 25°C) (-50... 110 °C/-58... 230 °F) +
Linear signals 0/10… 50mV, 0/12… 60mV
Linear signals 0/4… 20mA
Linear signals 0/1… 5V, 0/2… 10V
±0.5 % fs (tc S: ± 1% fs)
CONNECTIONS
65.5
4 different configurations
TLK72
4 red digit, h 12 mm + 3 LED Bargraph
72
DISPLAY
Single
INPUTS
+
88
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
TIMERS
COUNTERS
POWER LIMITERS
HOW TO ORDER
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•ON/OFF AND PID CONTROLLER
•rs485
•UP TO 3 RELAY OUTPUTS
26
27
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
INDUSTRIAL
CONTROLLERS
tlk96
24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz)
10 VA approx.
96 x 96 mm (1/4 DIN) - depth 73 mm / 250 g approx.
Flush in panel in 90 x 90 mm hole
Screw terminal block 2 x 1 mm²
IP 54, mounted on panel with gasket
0… 50°C (32… 122°F) / -10 ... 60 °C (14… 140°F)
30… 95 RH% without condensation
Directive CEE EMC 89/336 (EN 61326), Directive CEE BT 73/23 and 93/68 (EN 61010-1)
DIN RAIL
MOUNTING
CONTROLLERS
THERMOSTATS
ANALOGUE
CONTROLLERS
L
H
SPECIAL
CONTROLLERS
AND “CUSTOM”
C
E
I
V
R
O
-
PAC SYSTEMS
R
O
DIMENSIONS
PREPROGRAMMED
SYSTEMS
ON/OFF, Neutral Zone, PID
AUTOTUNING
ModBus
TLK96
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC (J,K,S,IRS)+PT100,mV
TC (J,K,S,IRS)+PTC,NTC,mV
0/4… 20mA
0/1… 5V, 0/2… 10V
OUT 1
Relay
Voltage for SSR driving
OUT 2
Relay
Voltage for SSR driving
Not available
tlk96
9
96
60
12
TLK 96
PLC AND
OPERATOR
PANELS
OUT 1 and OUT 2: Relay SPDT (8 A-AC1, 3 A-AC3 / 250 V AC) or voltage to drive SSR 8Vdc/8 mA
12 Vdc/20 mA max.
tlk96
To compose the part number, pls. choose one of the option for each variable
AT
CNT
OUT1
SET
OUT2
55
Accuracy
OUTPUTS
Up to 2
Auxiliary power supply
FUNCTIONAL
Control
PID functions
Serial communication
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
Thermocouples J (0... 1000 °C/ 32… 1832°F), K (0… 1370°C/32… 2498°F), S (0… 1760°C/32… 3200°F) and
Infrared sensors J or K + Thermoresistances Pt 100 3 wires (-200... 850 °C/-328... 1562 °F) +
Linear signals 0/10… 50mV, 0/12… 60mV
Thermocouples J (0... 1000 °C/ 32… 1832°F), K (0… 1370°C/32… 2498°F), S (0… 1760°C/32… 3200°F) and
Infrared sensors J or K + Thermistors PTC KTY 81-121 (990Ω at 25°C) (-55... 150 °C/-67... 302 °F) and
Thermistors NTC 103AT-2 (10 kΩ at 25°C) (-50... 110 °C/-58... 230 °F) +
Linear signals 0/10… 50mV, 0/12… 60mV
Linear signals 0/4… 20mA
Linear signals 0/1… 5V, 0/2… 10V
±0.5 % fs (tc S: ± 1% fs)
CONNECTIONS
88
4 different configurations
TLK96
4 red digit, h 14 mm
96
DISPLAY
Single
INPUTS
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
TIMERS
COUNTERS
POWER LIMITERS
HOW TO ORDER
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•ON/OFF AND PID CONTROLLER
•UP TO 2 RELAY OUTPUTS
28
29
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
Up to 4
FUNCTIONAL
Control
PID functions
Multi Set Point
Servomotor control
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
ON/OFF, PID single and double action, PID for servomotor control
AUTOTUNING, FAST TUNING, Selftuning
Up to 4 pre-programmable Set Point
3 points
On analogue output
RS485 with ModBus-RTU (JBUS) protocol
1200… 38400 baud, programmable
24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz)
10 VA approx.
48 x 96 mm (1/8 DIN) - depth 98 mm / 260 g approx.
Flush in panel in 45 x 92 mm hole
Screw terminal block 2 x 1 mm²
IP 54, mounted on panel with gasket
0… 50°C (32… 122°F) / -10 ... 60 °C (14… 140°F)
30… 95 RH% without condensation
Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1)
R
O
-
R
O
-
tc S
S
H
T
-
tc E
tc L
tc N
tc R
tc T
Pt100 (IEC)
97.5
Out4 Out5
PTC (KTY81-121)
NTC (103-AT2)
Pt1000 (IEC)
without DP
-160 ... 1000 °C
- 256 ... 1832 °F
-100 ... 1370 °C
- 148 ... 2498 °F
0 ... 1760 °C
32 ... 3200 °F
72 ... 1820 °C
162 ... 3308 °F
-150 ... 750 °C
-252 ... 1382 °F
-150 ... 900 °C
-252 ... 1652 °F
-250 ... 1300 °C
-418 ... 2372 °F
-50 ... 1760 °C
-58 ... 3200 °F
-250 ... 400 °C
-418 ... 752 °F
0 ... 2320 °C
32 ... 4208 °F
-46 ... 785 °C
-50 ... 1445 °F
-200 ... 850 °C
-50 ... 1445 °F
-55 ... 150 °C
-67 ... 302 °F
-50 ... 110 °C
-58 ... 230 °F
-200 ... 500 °C
-328 ... 932 °F
DIN RAIL
MOUNTING
CONTROLLERS
with DP
-160.0 ... 999.9 °C
-199.9 ... 999.9 °F
-100.0 ... 999.9 °C
-148.0 ... 999.9 °F
0.0 ... 999.9 °C
32.0 ... 999.9 °F
72.0 ... 999.9 °C
162.0 ... 999.9 °F
-150.0 ... 750.0 °C
-199.9 ... 999.9 °F
-150.0 ... 900.0 °C
-199.9 ... 999.9 °F
-199.9 ... 999.9 °C
-199.9 ... 999.9 °F
-50.0 ... 999.9 °C
-58.0 ... 999.9 °F
-199.9 ... 400.0 °C
-199.9 ... 752.0 °F
0.0 ... 999.9 °C
32.0 ... 999.9 °F
-46.0 ... 785.0 °C
-50.8 ... 999.9 °F
-199.9 ... 850.0 °C
-199.9 ... 999.9 °F
-55.0 ... 150.0 °C
-67.0 ...302.0 °F
-50.0 ... 110.0 °C
-58.0 ... 230.0 °F
-199.9 ... 500.0 °C
-199.9 ... 932.0 °F
COMBUSTION
CONTROL
SET
89.5
TUN
96
tc B
Infrared sensors
PV
TLK 94
The dimensions are expressed in mm
30
tc K
tc C
10
Out6
tlk94 temperature Ranges
INPUT
tc J
tlk94
SV
TEMPERATURE RANGES
R
O
-
DIMENSIONS
Out1 Out2 Out3
THERMOSTATS
ANALOGUE
CONTROLLERS
R
O
I
V
-
Note : When selected OUT 3, OUT 4 and OUT 5 must be identical.
(ALL Relay or ALL voltage for SSR driving).
48
SPECIAL
CONTROLLERS
AND “CUSTOM”
R
O
I
V
PAC SYSTEMS
Up to 6
OUT 1 : Relay SPST-NO (6 A-AC1, 3 A-AC3 / 250 V AC)
or 12Vdc/20 mA to drive SSR or 0/4… 20 mA or 0/2… 10 V
OUT 2: Relay SPST-NO (4 A-AC1, 2 A-AC3 / 250 V AC)
or 12Vdc/20 mA to drive SSR or 0/4… 20 mA or 0/2… 10 V
OUT 3, OUT 4, OUT 5 : Relay SPST-NO (4 A-AC1, 2 A-AC3 / 250 V AC)
or 12Vdc/20 mA to drive SSR
OUT6: 12Vdc/20 mA to drive SSR
12 Vdc/20 mA max.
L
H
PREPROGRAMMED
SYSTEMS
Accuracy
Current transformer (CT) input
Digital inputs
OUTPUTS
TLK94
Power supply
24 Vac/Vdc
100... 240 Vac/Vdc
OUT 1
Relay SPDT 6 A-AC1
Voltage for SSR driving
0/4… 20 mA
0/2… 10 V
OUT 2
Relay SPST-NO 4 A-AC1
Voltage for SSR driving
0/4… 20 mA
0/2… 10 V
Not available
OUT 3
Relay SPST-NO 4 A-AC1
Voltage for SSR driving
Not available
OUT 4
Relay SPST-NO 4 A-AC1
Voltage for SSR driving
Not available
OUT 5
Relay SPST-NO 4 A-AC1
Voltage for SSR driving
Not available
serial communication and digital INPUT
RS485
CT input
RS485 and CT input
Not available
PLC AND
OPERATOR
PANELS
Universal
Thermocouples J, K, S, B, C, E, L, N, R, T and Infrared sensors J or K +
Thermoresistances Pt 100 and Pt1000 3 wires +
Linear signals 0/10… 50mV, 0/4… 20mA, 0/12… 60mV, 0/1… 5V, 0/2… 10V
(see table next page for temperature ranges)
± 0.2 % fs + 1 digit; PTC/NTC: ± 0.5 % fs + 1 digit
CT 50 mA max. optoisolated
2 for free voltage contacts
tlk94
To compose the part number, pls. choose one of the option for each variable
TIMERS
COUNTERS
POWER LIMITERS
INPUTS
CONNECTIONS
INDICATORS
Dual display
TLK94
Main display: 4 red digit, h 10 mm
Secondary display: 4 green digit, h 7.5 mm
I/O MODULES
DISPLAY
SUPERVISION
HOW TO ORDER
FEATURES
ACCESSORIES
•UNIVERSAL INPUT
•RS485
•UP TO 5 OUTPUTS
•servomotor control
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
tlk94
31
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
INDUSTRIAL
CONTROLLERS
c1
Auxiliary power supply
FUNCTIONAL
Control
PID functions
Signal retransmission
Serial communication
(as alternative to retransmission output)
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
ON/OFF or PID single action
PID control with cycle time and overshoot control, 2 Autotuning algorithms
Measuring retransmission
Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires
1200... 9600 baud, programmable
100… 240 Vac/Vdc (-15...+10%), 24Vac(-25...+12%) and 24Vdc (-15...+25%) (50/60Hz)
3 VA max.
48 x 24 - depth 120 mm / 100 g approx.
Flush in panel in 45 x 22.2 mm hole
Screw terminal block M3 for cables with section 1 mm² (18AWG)
IP65
0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F)
5… 95% RH% without condensation
EN 61000-6-3:2001, EN 61000-6-4:2001, EN 61000-6-2:2001
Not available
RS485
special functions
Limit switch version
Not available
INSTRUCTION MANUAL
Italian/English
Not available
FRONT FRAME COLOUR
Dark grey
Dark grey + shunt 0.1%
special execution
Not available
On DIN rail
On DIN rail no display
Tropicalized
DIN RAIL
MOUNTING
CONTROLLERS
CODE
3
5
0
3
6
Options
Not available
Transmitter
Power supply
Transmitter
Power supply
+ retransmission
Not available
Transmitter
Power supply
THERMOSTATS
ANALOGUE
CONTROLLERS
C1
Power supply
100… 240 Vac/Vdc
24 Vac/Vdc
OUTPUTS
Relay
Triac
Voltage for SSR driving
serial communication
Pt100
00
Termocoppia
06
mV
Shunt
esterno
2.5Ω
mA
07
50
56
DIMENSIONS
c1
9
0
0
9
0
2
0
1
2
3
48
SPECIAL
CONTROLLERS
AND “CUSTOM”
Up to 3
OUT 1: Relay SPST-NO 2A/250Vac-AC1 / Triac 1A/250Vac-AC1
OUT 2: 5Vdc 30mA max., ± 10% (not isolated) to drive SSR
OUT 3 (opt.): Measuring retransmission, current: 0/4… 20mA 750Ω/15V max. (as alternative to RS485)
+18Vdc ±20%, 30mA max. for external transmitter
c1
To compose the part number, pls. choose one of the option for each variable
PAC SYSTEMS
Accuracy
OUTPUTS
Thermocouples: L ,J (0… 600°C/32… 1112°F), T (-200… 400/-328… 752°F),
K (0…1200°C/32… 2192°F), S (0… 1600°C/32… 2912°F) +
Thermoresistances PT100 (-200… 600°C/-328… 1112°F
or -99.9… 300.0°C/-99.9… 572.9°F) connection with 2 or 3 wires +
Linear signals: 0/10... 50 mV; 0/4…20 mA +
Infrared sensors or special ranges (custom)
0.25% ±1 digit (for thermoelements); 0.1% ±1 digit (for mA and mV)
CONNECTIONS
PREPROGRAMMED
SYSTEMS
Universal
C1
4 green digit, h 9 mm + 3 LEDs
120
25
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
PLC AND
OPERATOR
PANELS
DISPLAY
Single
INPUTS
TIMERS
COUNTERS
POWER LIMITERS
HOW TO ORDER
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•controller / Indicator
•with 1 or 2 alarms
32
33
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
INDUSTRIAL
CONTROLLERS
m1
ON/OFF or PID single action
PID control with cycle time and overshoot control, 2 Autotuning algorithms
Measuring or Set Point retransmission
Not available
RS485
Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires
1200... 9600 baud, programmable
100… 240 Vac/Vdc (-15...+10%), 24Vac(-25...+12%) and 24Vdc (-15...+25%) (50/60Hz)
3.5 VA max.
48 x 48 - depth 120 mm / 130 g approx.
Flush in panel in 45 x 45 mm hole
Screw terminal block M3 for cables with section 1 mm² (18AWG)
IP65
0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F)
5… 95% RH% without condensation
EN 61000-6-3:2001, EN 61000-6-4:2001, EN 61000-6-2:2001
SPECIAL FUNCTIONS
Limit switch version
Not available
INSTRUCTION MANUAL
Italian/English
Not available
FRONT FRAME COLOUR
Dark grey
Dark grey + shunt 0.1%
SPECIAL EXECUTION
Not available
On DIN rail
On DIN rail no display
Tropicalized
DIN RAIL
MOUNTING
CONTROLLERS
CODE
THERMOSTATS
ANALOGUE
CONTROLLERS
3
5
0
3
6
7
OPTIONS
Not available
Transmitter
Power supply
Transmitter
Power supply
+ retransmission
Not available
Transmitter
Power supply
mV
Termocoppia
Shunt
esterno
2.5Ω
00
06
Pt100
mA
07
50
56
DIMENSIONS
m1
9
0
0
9
0
2
0
1
2
3
48
120
48
10 max.
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
Auxiliary power supply
FUNCTIONAL
Control
PID functions
Signal retransmission
Serial communication
(as alternative to retransmission output)
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1: Relay SPST-NO 2A/250Vac-AC1 / Triac 1A/250Vac-AC1
OUT 2 + OUT 3: 5Vdc 30mA max., ± 10% (not isolated) to drive SSR / Relay SPST-NO (2A/250Vac-AC1)
OUT 4 (opt.): Measuring or Set Point retransmission, current: 0/4… 20mA 750Ω/15V max. (as alternative to RS485)
+18Vdc ±20%, 30mA max. for external transmitter
M1
Power supply
100… 240 Vac/Vdc
24 Vac/Vdc
OUTPUTS
Relay/Relay
Triac/Relay
Relay/Voltage for SSR driving
Relay/triac
serial communication
SPECIAL
CONTROLLERS
AND “CUSTOM”
Up to 4
m1
To compose the part number, pls. choose one of the option for each variable
PAC SYSTEMS
Accuracy
OUTPUTS
Thermocouples: L ,J (0… 600°C/32… 1112°F), T (-200… 400/-328… 752°F),
K (0…1200°C/32… 2192°F), S (0… 1600°C/32… 2912°F) +
Thermoresistances PT100 (-200… 600°C/-328… 1112°F
or -99.9… 300.0°C/-99.9… 572.9°F) connection with 2 or 3 wires +
Linear signals: 0/10... 50 mV; 0/4…20 mA +
Infrared sensors or special ranges (custom)
0.25% ±1 digit (for thermoelements); 0.1% ±1 digit (for mA and mV)
CONNECTIONS
PREPROGRAMMED
SYSTEMS
Universal
M1
4 green digit, h 10 mm + 6 LEDs
PLC AND
OPERATOR
PANELS
DISPLAY
Single
INPUTS
TIMERS
COUNTERS
POWER LIMITERS
HOW TO ORDER
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•controller / Indicator /
transmitter
•with 1 or 2 alarms
34
35
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
INDUSTRIAL
CONTROLLERS
m2
Up to 3
Auxiliary power supply
FUNCTIONAL
Control
PID functions
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1: Relay SPST-NO 2A/250Vac-AC1
OUT 2: 5Vdc, ±10%, 30mA max. (not isolated) to drive SSR / Relay SPST-NO, 2A/250Vac-AC1
OUT 3: Relay SPST-NO 2A/250Vac-AC1
+18Vdc ±20%, 30mA max. for external transmitter
ON/OFF, PID a singola/doppia azione
Dead band, relative cooling gain, cooling sampling time, overshoot control, higher limit
Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires
1200... 9600 baud, programmable
100… 240Vac (-15...+10%) o 24Vdc (-25...+12%) e 24Vdc (-15...+25%) (50/60Hz)
2.6 VA max.
48 x 48 - depth 120 mm / 130 g
Flush in panel in 45 x 45 hole
Screw terminal block M3 for cables with section 1 mm² (18AWG)
IP65
0… 50°C (32… 122°F) / -20…+70°C (-4… 158°F)
5… 95% RH without condensation
EN 61010-1
Not available
INPUT digitale
DIN RAIL
MOUNTING
CONTROLLERS
CODE
9
Ingresso digitale
10
3
5
11
THERMOSTATS
ANALOGUE
CONTROLLERS
Accuracy
Auxiliary input
Digital inputs
OUTPUTS
M2
Power supply
100… 240 Vac/Vdc
24 Vac/Vdc
OUT 2
Relay/Voltage for SSR driving
Voltage for SSR driving
INPUT digitale
1
6
OPTIONS
Not available
Current Transformer
input (CT)
Not available
Current Transformer
input (CT)
SPECIAL FUNCTIONS
Not available
SP modification from digital input
Average Safety Output
SP modification from digital input + Average Safety Output
INSTRUCTION MANUAL
Italian/English
Not available
FRONT FRAME COLOUR
Dark grey
Dark grey + shunt 0.1%
SPECIAL EXECUTION
Not available
On DIN rail
On DIN rail no display
Tropicalized
mV
00
Shunt
esterno
2.5Ω
03
90
0
9
Trasformatore
amperometrico
Pt100
mA
93
0
6
7
8
Termocoppia
DIMENSIONS
m2
48
120
0
2
0
1
2
3
SPECIAL
CONTROLLERS
AND “CUSTOM”
Universal
Thermocouples: L/J (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F),
K (0…+1200°C / 32…+2192°F), S (0... +1600°C / 32...2912°F)
Thermoresistances: PT100 connection with 2 or 3 wires (-200... +600°C / -328... +1112°F)
Linear signals: 0/10... 50 mV; 0/4…20 mA
Infrared sensors or special ranges (custom)
0.25% ±1 digit (for thermoelements); 0.1% ±1 digit (for mA and mV)
Current Transformer for Heater Break function
1 digital input for free voltage contacts
m2
To compose the part number, pls. choose one of the option for each variable
PAC SYSTEMS
INPUTS
CONNECTIONS
PREPROGRAMMED
SYSTEMS
Dual
M2
Main display: 4 green digit, h 10 mm
Secondary display: 4 green digit, h 8 mm + 6 LEDs
PLC AND
OPERATOR
PANELS
DISPLAY
48
10 max.
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
TIMERS
COUNTERS
POWER LIMITERS
HOW TO ORDER
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•temperaturE CONTROLLER
FOR HOT RUNNERS
36
37
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
INDUSTRIAL
CONTROLLERS
m3 / m4
Up to 4
Auxiliary power supply
Outputs configurations
FUNCTIONAL
Control
Alarms
PID functions
Special functions
Signal retransmission
Serial communication (opt.)
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1: Relay SPST-NO 2A/250Vac-AC1 / Triac
OUT 2: 5Vdc, ±10%, 30mA max.(not isolated) to drive SSR / Relay SPST-NO, 2A/250Vac-AC1
OUT 3: Relay SPST-NO 2A/250Vac-AC1 / Triac
OUT 4 (opt.): Measuring or Set Point retransmission,
OUT 4: (Opt.) control output,
current: 0/4… 20mA 750Ω/15V max. (as alternative to RS485)
current: 0/4… 20mA 750Ω/15V max.
+18Vdc ±20%, 30mA max. for external transmitter
1 loop PID or ON/OFF double action with 1 or 2 alarms
ON/OFF or PID single/double action
2 alarms programmable as high/low or band alarm
Hysteresis 0.1… 10.0% e.s.
Dead band, relative cooling gain, cooling sampling time, overshoot control, higher limit
Sensor Break, Heater Break, Latching/Blocking and loop break
Measuring or Set Point retransmission
Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires
1200... 9600 baud, programmable
100… 240 Vac (-15...+10%) o 24Vac (-25...+12%) and 24Vdc (-15...+25%) (50/60Hz)
6 VA max.
48 x 48 - depth 120 mm / 130 g
Flush in panel in 45 x 45 mm hole
Screw terminal block M3 for cables with section 1 mm² (18AWG)
IP65
0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F)
5… 95% RH without condensation
EN 61010-1
DIN RAIL
MOUNTING
CONTROLLERS
THERMOSTATS
ANALOGUE
CONTROLLERS
External
shunt 2.5Ω
Thermo
couple
Current
transformer
Pt100
mA
m4
00
03
06
07
mV
08
External
shunt 2.5Ω
09
Thermo
couple
Current
transformer
Pt100
Logic input
50
mA
56
58
90
93
DIMENSIONS
m3 / m4
97
99
0
2
9
0
9
0
2
0
1
2
3
(*) With code 07 and code 09, the analogue output can be used also as control
output.
38
mV
PAC SYSTEMS
Auxiliary input (optional)
OUTPUTS
0
1
2
4
5
7
8
PREPROGRAMMED
SYSTEMS
Digital inputs
3
5
PLC AND
OPERATOR
PANELS
Accuracy
CODE
TIMERS
COUNTERS
POWER LIMITERS
Universal
Thermocouples: L/J (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F),
K (0…+1200°C / 32…+2192°F), S (0... +1600°C / 32...2912°F)
Thermoresistances: PT100 connection with 2 or 3 wires (-200... +600°C / -328... +1112°F)
Linear signals: 0/10... 50 mV; 0/4…20 mA
Infrared sensors or special ranges (custom)
0.25% ±1 digit (for thermoelements); 0.1% ±1 digit (for mA and mV)
Auto/man switching, stand-by/Set Point
-switching, keyboard lock, timer
Current Transformer for Heater Break function
M3 / M4
Power supply
100… 240 Vac/Vdc
24 Vac/Vdc
OUT 1, 2 e 3
Relay/Relay/Voltage for SSR driving
Relay/Relay/Voltage for SSR driving + Relay
Relay/Relay/Voltage for SSR driving + triac
Triac/Relay/Voltage for SSR driving + Relay
Triac/Relay/Voltage for SSR driving + triac
Relay + triac/Voltage for SSR driving + Relay (M3 only)
Relay + Voltage for SSR driving (M3 only)
Serial communication +
OPTIONS
digital INPUT
Not available
Current Transformer
input (CT)
Transmitter supply
18V
Transmitter supply
18V
Not available
+ Retransmission (*)
+ CT input
Transmitter supply
18V+ CT input
Transmitter supply
18V + CT input
+ Retransmission (*)
Not available
Transmitter supply
18V
RS485
Transmitter supply
18V + CT input
Not available
CT input
Analogue
INPUT digitale (Solo M4)
Control Output
Analogue
Control Output
+ CT input
SPECIAL FUNCTIONS
Not available
Start-up + Timer
Limit switch version
INSTRUCTION MANUAL
Italian/English
Not available
FRONT FRAME COLOUR
Dark grey
Dark grey + shunt 0,1%
SPECIAL EXECUTION
Not available
On DIN rail
Mounting B/DIN, No display
Tropicalized
48
INDICATORS
INPUTS
m3
To compose the part number, pls. choose one of the option for each variable
120
I/O MODULES
Main display: 4 green digit, h 10 mm
Secondary display: 4 green digit, h 6.75 mm + 5 LEDs
CONNECTIONS
48
10 max.
SUPERVISION
M4
The dimensions are expressed in mm
COMBUSTION
CONTROL
Dual
M3
ACCESSORIES
DISPLAY
SPECIAL
CONTROLLERS
AND “CUSTOM”
HOW TO ORDER
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•Regolatore caldo-freddo
•Regolatore caldo-freddo
con uscita continua
39
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
INDUSTRIAL
CONTROLLERS
x1 / x3
Up to 5
Analogue control output
Auxiliary power supply
FUNCTIONAL
Control
Alarms
PID functions
Double action
(Heat-Cool) with overlap
Servomotor control
(without position potentiometer)
Pre-programmed Set Point
Special functions
Tuning
Auto/Man Station
PID with overshoot control or ON/OFF
single/double action with 1, 2 or 3 alarms
PID with overshoot control or ON/OFF
single/double action with 1, 2 or 3 alarms
PID for Servomotor control
Up to 3
Error dead band, overshoot control, manual reset, cycle time,
Control output high limit, Soft-start output valve, output safety value
Dead band, Relative cool gain, cycle time (time proportional output),
Cool output high limit
For X3 only: Cool output hysteresis
--
Motor travel time, motor minimum step
1 program, 8 segments 1 initial and 1 end,
-from 1 to 9999 cycles/continuous cycling
Timer (1… 9999s/min), Stand-by Set Point, Start-up, Start-up Set Point
One Shot Tuning
Fuzzy Tuning One Shot
Standard with Bumpless function, by keypad
-digital input or serial communication
Measuring or Set Point retransmission
Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires
1200, 2400, 4800, 9600 bit/sec, 2 wires
100… 240Vac (-15… +10%) or 24Vac (-25… +12%) and 24Vdc (-15… +25%) / 50/60Hz
6VA max.
48 x 96 mm - depth 110 mm / 250 g approx.
Flush in panel in 45 x 92 mm hole
Screw terminal block M3 for cables with section 1 mm² (18AWG)
IP65
0… 50°C (32… 122°F) / -20…+70°C (-4… 158°F)
5… 95% RH without condensation
EN 61010-1
DIN RAIL
MOUNTING
CONTROLLERS
THERMOSTATS
ANALOGUE
CONTROLLERS
V
Current
Transformer
mV
0
5
mA
mA
Thermocouple
External
shunt 2.5Ω
Pt100
0
2
5
5
7
X3
TTL
0
2
3
NPN
NO
V
Current
Transformer
0
9
mV
0
2
Pt100
mA
Thermocouple
mA
External
shunt 2.5Ω
0
3
DIMENSIONS
x1 / x3
48
110
96
10 max.
The dimensions are expressed in mm
ACCESSORIES
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1: Relay, NO, 2A/250Vac (4A/120Vac) or TRIAC 1A/250Vac
OUT 2: Relay, NO, 2A/250Vac (4A/120Vac) or TRIAC 1A/250Vac
OUT 3: Relay,SPDT, 2A/250Vac (4A/120Vac)
OUT 4: Relay, SPDT, 2A/250Vac (4A/120Vac) or Logic not isolated: 0/5Vdc, ±10% 30mA max.
OUT 5: Analogue for Measuring or Set Point retransmission, current: 0/4… 20mA max. 750Ω/10V max.
Measuring or Set Point retransmission, current: 0/4… 20mA 750Ω/15V max. or
voltage: 0… 1/5/10V 500Ω/20mA max.
+18Vdc ±20%, 30mA max. for external transmitter (2, 3 or 4 wires)
1
5
9
SPECIAL
CONTROLLERS
AND “CUSTOM”
Digital inputs
OUTPUTS
3
5
PAC SYSTEMS
Auxiliary input
CODE
PREPROGRAMMED
SYSTEMS
Accuracy
X1 / X3
Power supply
100… 240 Vac/Vdc
24 Vac/Vdc
OUT 1,out 2, out 3 and out 4
Relay-Relay-Relay-Voltage for SSR driving
Triac-triac-Relay-Voltage for SSR driving
Relay-Relay-Relay-Relay
Serial communication
Not available
RS485
OPTIONS
Not available
Servomotor (X3 only)
Retransmission + Remote Set Point (X1 only)
Analogue Output + Remote Set Point (X3 only)
Servomotor + Analogue Output + Remote Set Point (X3 only)
SPECIAL FUNCTIONS
Not available
Start-up + Timer
1 Program 8 segments (X3 only)
INSTRUCTION MANUAL
Italian/English
Not available
FRONT FRAME COLOUR
Dark grey
Dark grey + shunt 0.1%
SPECIAL EXECUTION
Not available
Tropicalized
PLC AND
OPERATOR
PANELS
Universal
Thermocouples: L/J (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F),
K (0…+1200°C / 32…+2192°F), S/R (0... +1600°C / 32...2912°F)
Thermoresistances: PT100 connection with 2 or 3 wires (-200... +600°C / -328... +1112°F)
Linear signals: 0/10... 50 mV; 0/4…20 mA
Infrared sensors or special ranges (custom)
0.25% ±1 digit (for thermoelements); 0.1% ±1 digit (for mA and mV)
Non isolated remote Set Point: current 0/4… 20mA or voltage 1… 5/ 0… 5/ 0… 10V
Current Transformer for Heater Break function
-3
X1
To compose the part number, pls. choose one of the option for each variable
TIMERS
COUNTERS
POWER LIMITERS
INPUTS
CONNECTIONS
INDICATORS
X3
Main display: 4 green digit, h 10 mm
Secondary display: 4 green digit, h 9 mm + 16 LEDs,
I/O MODULES
Dual
X1
Main display: 4 green digit, h 10 mm
Secondary display: 4 green digit, h 9 mm + 11 LEDs
SUPERVISION
DISPLAY
COMBUSTION
CONTROL
HOW TO ORDER
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•heat-cool temperature
controllers
•double action controller with
analogue output
40
41
IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs
INDUSTRIAL
CONTROLLERS
q1 / q3
Up to 5
Auxiliary power supply
FUNCTIONAL
Control
Alarms
PID functions
Double action
(Heat-Cool) with overlap
Servomotor control
(without position potentiometer)
Pre-programmed Set Point
Special functions
Tuning
Auto/Man Station
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1: Relay, NO, 2A/250Vac (4A/120Vac) or TRIAC 1A/250Vac
OUT 2: Relay, NO, 2A/250Vac (4A/120Vac) or TRIAC 1A/250Vac
OUT 3: Relay,SPDT, 2A/250Vac (4A/120Vac)
OUT 4: Logic not isolated: 0/5Vdc, ±10% 30mA max. for retransmission
OUT 5: Analogue for Measuring or Set Point retransmission, current: 0/4… 20mA max. 750Ω/10V max.
+18Vdc ±20%, 30mA max. for external transmitter (2, 3 or 4 wires)
PID with overshoot control or ON/OFF
single/double action with 1, 2 or 3 alarms
PID with overshoot control or ON/OFF
single/double action with 1, 2 or 3 alarms
PID for Servomotor control
Up to 3
Error dead band, overshoot control, manual reset, cycle time,
Control output high limit, Soft-start output valve, output safety value
Dead band, Relative cool gain, cycle time (time proportional output),
Cool output high limit
For Q3 only: Cool output hysteresis
--
Motor travel time, motor minimum step
1 program, 8 segments 1 initial and 1 end,
from 1 to 9999 cycles/continuous cycling
Timer (1… 9999s/min), Stand-by Set Point, Start-up, Start-up Set Point
One Shot Tuning
Fuzzy Tuning One Shot
Standard with Bumpless function, by keypad
-digital input or serial communication
Measuring or Set Point retransmission
Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires
1200, 2400, 4800, 9600 bit/sec, 2 wires
--
100… 240Vac (-15… +10%) or 24Vac (-25… +12%) and 24Vdc (-15… +25%) / 50/60Hz
6 VA max.
96 x 96 mm - depth 110 mm / 470 g approx.
Flush in panel in 92 x 92 mm hole
Screw terminal block M3 for cables with section 1 mm² (18AWG)
IP65
0… 50°C (32… 122°F) /-20…+70°C (-4… 158°F)
5… 95% RH without condensation
EN 61010-1
DIN RAIL
MOUNTING
CONTROLLERS
V
Current
Transformer
mV
0
5
mA
mA
Thermocouple
External
shunt 2.5Ω
Pt100
0
2
5
5
7
q3
TTL
0
2
3
NPN
NO
V
Current
Transformer
0
9
mV
0
2
Pt100
0
3
THERMOSTATS
ANALOGUE
CONTROLLERS
1
5
9
SPECIAL
CONTROLLERS
AND “CUSTOM”
Digital inputs
OUTPUTS
3
5
PAC SYSTEMS
Auxiliary input
CODE
PREPROGRAMMED
SYSTEMS
Accuracy
Q1 / Q3
Power supply
100… 240 Vac/Vdc
24 Vac/Vdc
OUT 1,out 2, out 3 and out 4
Relay-Relay-Relay-Voltage for SSR driving
Triac-triac-Relay-Voltage for SSR driving
Relay-Relay-Relay-Relay
Serial communication
Not available
RS485
OPTIONS
Not available
Servomotor (Q3 only)
Retransmission + Remote Set Point (Q1 only)
Analogue Output + Remote Set Point (Q3 only)
Servomotor + Analogue Output + Remote Set Point (Q3 only)
SPECIAL FUNCTIONS
Not available
Start-up + Timer
1 Program 8 segments (Q3 only)
INSTRUCTION MANUAL
Italian/English
Not available
FRONT FRAME COLOUR
Dark grey
Dark grey + shunt 0.1%
SPECIAL EXECUTION
Not available
Tropicalized
mA
mA
Thermocouple
PLC AND
OPERATOR
PANELS
Universal
Thermocouples: L/J (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F),
K (0…+1200°C / 32…+2192°F), S (0... +1600°C / 32...2912°F)
Thermoresistances: PT100 connection with 2 or 3 wires (-200... +600°C / -328... +1112°F)
Linear signals: 0/10... 50 mV; 0/4…20 mA
Infrared sensors or special ranges (custom)
0.25% ±1 digit (for thermoelements); 0.1% ±1 digit (for mA and mV)
Non isolated remote Set Point: current 0/4… 20mA or voltage 1… 5/ 0… 5/ 0… 10V
Current Transformer for Heater Break function
-3
q1
To compose the part number, pls. choose one of the option for each variable
External
shunt 2.5Ω
TIMERS
COUNTERS
POWER LIMITERS
INPUTS
CONNECTIONS
DIMENSIONS
q1 / q3
96
INDICATORS
Q3
Main display: 4 green digit, h 15 mm
Secondary display: 4 green digit, h 12 mm + 16 LEDs
110
I/O MODULES
Dual
HOW TO ORDER
Q1
Main display: 4 green digit, h 15 mm
Secondary display: 4 green digit, h 12 mm + 11 LEDs
96
10 max.
SUPERVISION
FEATURES
DISPLAY
ADVANCED
PROGRAMMER
CONTROLLERS
•heat-cool temperature
controllers
•double action controller with
analogue output
ACCESSORIES
COMBUSTION
CONTROL
The dimensions are expressed in mm
42
43
ADVANCED PROGRAMMER
CONTROLLERS
The most complete range you may
wish!
Single and muliloop controllers and advanced programmers, multifunction and with
incorporated and independent timer, in all sizes.
New KUBE line: more and more in less space!
Pocket size, energy saving functions and advanced features.
44
45
ADVANCED programmER CONTROLLERS
Control
K49
·
·
K85
K30
M5
X5
Q5
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
2
·
3
·
·
·
3
·
·
4
2
·
4
2
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Universal
J-K-S-R-T + IR + PTC-NTC
J-K-S-R-T + IR + Pt100
∆T PT100
Digital
Frequency
Potentiometer
For CT
12 Vac/Vdc
24 Vac/Vdc
100… 240 Vac
ON/OFF and PID
Servomotor control
·
2
·
2
·
2
4
1
·
4
1
·
4
1
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
2
2
·
·
·
·
·
·
·
·
·
·
2
2
2
·
·
4
4
2
2
3
3
3
5
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
3
1
·
·
·
·
·
·
·
·
·
THERMOSTATS
ANALOGUE
CONTROLLERS
K48
SPECIAL
CONTROLLERS
AND “CUSTOM”
K39
·
PAC SYSTEMS
K38
·
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
RS485 ModBus Slave
RS485 ModBus Master
Profibus DP
Mathematical package
Timer on board
Programmer
CE certification
UL approval
ENEC approval
K32
·
·
·
Relay or voltage for SSR drive outputs
Analogue current or voltage outputs
Measuring or Set Point retransmission
Power supply
K31
·
PREPROGRAMMED
SYSTEMS
Input
KR3
·
PLC AND
OPERATOR
PANELS
3 dynamic colour dual LED display
4 digit Single display
4 digit Dual display
4 digit Triple display
"Sensitive Touch" keyboard
KX3
TIMERS
COUNTERS
POWER LIMITERS
Dimensions (mm)
KM3
78x35
48x48
48x96
70 x 84
4 DIN Modules
96x96
INDICATORS
FEATURES
DIN RAIL
MOUNTING
CONTROLLERS
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S
46
47
Up to 4
FUNCTIONAL
Control
24 Vac/Vdc ± 10%, 100… 240 Vac/Vdc -15%/+ 10% (50/60 Hz)
7 VA max
48 x 48 mm (1/16 DIN) - depth 63 mm / 125 g
Flush in panel in 45 x 45 mm hole
16 screw terminals 2.5 mm² (AWG22…. AWG14) fix, plug-in or clamp type
IP 65, mounted on panel with gasket
0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F)
20… 95 RH% without condensation
EN 61010-1, EN 61326
mV, V
mA
3 wires
DIN RAIL
MOUNTING
CONTROLLERS
TERMINALS
R
O
R
O
-
L
Pin connector:
1.4 mm - 0.055 in. max.
Stripped wire
L 5.5 mm - 0.21 in.
q
PV
Note: Terminal 4 can be programmed as:
- Digital Input (DI2) connecting a free of voltage
contact between terminals 4 and 16
- 0... 12 V SSR Drive Output (OP4) connecting the load
between terminals 4 and 16
- 12 Vdc (20 mA) transmitter power supply
connecting the transmitter between terminals 4 and 1
Transducer
Passive 4... 20 mA
Pt1000/NTC/PTC
Pt100
DIMENSIONS
km3
48
11
14
48
D
S
E
N
M
-
THERMOSTATS
ANALOGUE
CONTROLLERS
Line 100... 240 VAC/
20... 30 VDC
Neutral
Thermocouple
SPECIAL
CONTROLLERS
AND “CUSTOM”
Transducer
R
O
I
Close
12 VDC
(note)
PV
12 VDC
(note)
C
E
Open
OP3 *
Terminals
18
10
15
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
Alarms
Set Point
Signal retransmission
Serial communication
Baud rate
Working hours counters
Wattmeter function
EVOogreen
Programmer (optional)
Timer (optional)
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
PID single or double action, ON/OFF, ON/OFF with Neutral Zone
Autotuning and Selftuning algorithms, Overshoot control
3 alarms programmable as absolute, deviation, band
4 programmable Set Points
Measuring or Set Point retransmission
TTL (standard) + RS485 (optional), ModBus RTU protocol
1200… 38400 baud
A cumulative non-erasable counter and a second one resettable with alarm
Instantaneous power, time consumption
Stand-by mode of display, selectable
Up to 8 segments with guaranteed soak
Independent with 5 function modes
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
OUT 1: Relay SPST-NO 4A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10%
or analogue galvanically isolated 0/4... 20 mA, 0/2... 10V (optional)
OUT 2: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10%
OUT 3: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 110.5V min. @ 15mA ±10%
OUT 4 programmable: voltage output to drive SSR 13V max. @ 1mA, 10.5V min. @ 22mA ±10%
or transmitter supply or 2nd digital input
OP4
(note)
Analogue input
2 wires
L
H
OP2 *
DI2 (note)
PAC SYSTEMS
OUTPUTS
T
P
DI1
OP1
RS485
PREPROGRAMMED
SYSTEMS
Digital inputs
CODE
PLC AND
OPERATOR
PANELS
Accuracy
KM3
Version
Controller
Controller + Timer
Controller + Timer + Programmer
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC, RTD, mA, V, mV/digital input 1
TC, NTC, PTC, mA, V, mV/digital input 1
OUT 1
Relay SPST 4A
Vdc for SSR driving
0/4… 20 mA, 0/2... 10V galvanically isolated
(control and retransmission)
OUT 2
Relay SPST 2A
Vdc for SSR driving
Not available
OUT 3
Relay SPST 2A
Vdc for SSR driving
Not available
OUT 4
Digital input 2 or digital output or transmitter supply
RS485
Available
Not available
connection
Plug-in screw type
Plug-in screw type, fix part only
Clamp type
Fix screw type (standard)
TIMERS
COUNTERS
POWER LIMITERS
Universal
Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F),
S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F)
Infrared sensors: J or K
Thermoresistances: 3 wires Pt 100 and 2 wires Pt 1000 (-200... 850°C/-328... 1562°F)
Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V
Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F),
S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F)
Infrared sensors: J or K
Thermistors: PTC KTY81-121 (-55... +150°C/-67... 302°F), NTC 103 AT2 (-50... +110°C/-58... 230°F)
Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V
± 0.5% span ±1 digit, (±1% span ±1 digit for T/c S type)
1 or 2 according to instrument’s part number
(the 2nd digital input is alternative to OUT 4)
km3
To compose the part number, pls. choose one of the option for each variable
INDICATORS
INPUTS
CONNECTIONS
I/O MODULES
Dual LED
KM3
Main display: 4 digit h 15.5 mm. 3 colours: red, green and amber
Secondary display: 4 green digit, h 7 mm
14
DISPLAY
SUPERVISION
HOW TO ORDER
FEATURES
45
•3 dynamic colour led display
•analogUE CONTROL OUTPUT
•8 segmentS PROGRAMMER / Timer
•WORKING hours counter
48
km3
IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S
48
49
Up to 4
OUT 1: Relay SPST-NO 4A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10%
or analogue galvanically isolated 0/4... 20 mA, 0/2... 10V (optional)
OUT 2: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10%
OUT 3: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 110.5V min. @ 15mA ±10%
OUT 4 programmable: voltage output to drive SSR 13V max. @ 1mA, 10.5V min. @ 22mA ±10%
or transmitter supply or 2nd digital input
FUNCTIONAL
Control
24 Vac/Vdc ± 10%, 100… 240 Vac/Vdc -15%/+ 10% (50/60 Hz)
7 VA max
48 x 96 mm (1/8 DIN) - depth 76 mm / 160 g
Flush in panel in 45 x 93 mm hole
16 screw terminals 2.5 mm² (AWG22…. AWG14) fix, plug-in or clamp type
IP 65 mounted on panel with gasket
0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F)
20… 95 RH% without condensation
EN 61010-1, EN 61326
DIN RAIL
MOUNTING
CONTROLLERS
Stripped wire
L 5.5 mm - 0.21 in.
NO
L
H
OP3 *
C
THERMOSTATS
ANALOGUE
CONTROLLERS
Close
Note: Terminal 4 can be programmed as:
- Digital Input (DI2) connecting a free of voltage
contact between terminals 4 and 5
- 0... 12 V SSR Drive Output (OP4) connecting
the load between terminals 4 and 5
- 12 Vdc (20 mA) transmitter power supply
connecting the transmitter between
terminals 4 and 1
NO
Open
OP2 *
C
NA
RS485
Analogue input
OP1
C
KX3 only
SPECIAL
CONTROLLERS
AND “CUSTOM”
q
T
P
100... 240 Vac/ Fase
20... 30 Vdc
Neutral
L
Pin connector:
1.4 mm - 0.055 in. max.
DI1
Pt1000/NTC/PTC
C
E
12 Vdc (note)
OP4
(note)
2 wires
PV
Transducer
R
O
R
O
-
DI2
(note)
3 wires
PV
I
Pt100
Passive 4... 20 mA
Transducer
12 Vdc
(note)
mV, V
mA
Thermocouple
DIMENSIONS
kx3
48
11
62
14
18
R
O
D
S
E
N
M
-
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
Alarms
Set Point
Signal retransmission
Serial communication
Baud rate
Working hours counters
Wattmeter function
EVOogreen
Programmer (optional)
Timer (optional)
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
PID single or double action, ON/OFF, ON/OFF with Neutral Zone
Autotuning and Selftuning algorithms, Overshoot control
3 alarms programmable as absolute, deviation, band
4 programmable Set Points
Measuring or Set Point retransmission
TTL (standard) + RS485 (optional), ModBus RTU protocol
1200… 38400 baud
A cumulative non-erasable counter and a second one resettable with alarm
Instantaneous power, time consumption
Stand-by mode of display, selectable
Up to 8 segments with guaranteed soak
Independent with 5 function modes
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
OUTPUTS
TERMINALS
PAC SYSTEMS
Digital inputs
CODE
PREPROGRAMMED
SYSTEMS
Accuracy
KX3
VERSION
Controller
Controller + Timer
Controller + Timer + Programmer
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC, RTD, mA, V, mV/digital input 1
TC, NTC, PTC, mA, V, mV/digital input 1
OUT 1
Relay SPST 4A
Vdc for SSR driving
0/4… 20 mA, 0/2... 10V galvanically isolated
(control and retransmission)
OUT 2
Relay SPST 2A
Vdc for SSR driving
Not available
OUT 3
Relay SPST 2A
Vdc for SSR driving
Not available
OUT 4
Digital input 2 or digital output or transmitter supply
RS485
Available
Not available
connection
Plug-in screw type
Plug-in screw type, fix part only
Clamp type
Fix screw type (standard)
PLC AND
OPERATOR
PANELS
Universal
Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F),
S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F)
Infrared sensors: J or K
Thermoresistances: 3 wires Pt 100 and 2 wires Pt 1000 (-200... 850°C/-328... 1562°F)
Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V
Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F),
S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F)
Infrared sensors: J or K
Thermistors: PTC KTY81-121 (-55... +150°C/-67... 302°F), NTC 103 AT2 (-50... +110°C/-58... 230°F)
Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V
± 0.5% span ±1 digit, (±1% span ±1 digit for T/c S type)
1 or 2 according to instrument’s part number
(the 2nd digital input is alternative to OUT 4)
kx3
To compose the part number, pls. choose one of the option for each variable
TIMERS
COUNTERS
POWER LIMITERS
INPUTS
CONNECTIONS
INDICATORS
Dual LED
KX3
Main display: 4 digit h 15.5 mm. 3 colours: red, green and amber
Secondary display: 4 green digit, h 10 mm
20 segments Bargraph
I/O MODULES
DISPLAY
SUPERVISION
HOW TO ORDER
FEATURES
89
•3 dynamic colour led display
•analogUE CONTROL OUTPUT
•8 segmentS PROGRAMMER / Timer
•WORKING hours counter
96
KX3
IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S
50
51
Up to 4
OUT 1: Relay SPDT 4A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10%
or analogue galvanically isolated 0/4... 20 mA, 0/2... 10V (optional)
OUT 2: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10%
OUT 3: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 110.5V min. @ 15mA ±10%
OUT 4 programmable: voltage output to drive SSR 13V max. @ 1mA, 10.5V min. @ 22mA ±10%
or transmitter supply or 2nd digital input
FUNCTIONAL
Control
24 Vac/Vdc ± 10%, 100… 240 Vac/Vdc -15%/+ 10% (50/60 Hz)
7 VA max
48 x 48 mm (1/16 DIN) - depth 63 mm / 125 g
Flush in panel in 45 x 45 mm hole
16 screw terminals 2.5 mm² (AWG22…. AWG14) fix, plug-in or clamp type
IP 65, mounted on panel with gasket
0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F)
20… 95 RH% without condensation
EN 61010-1, EN 61326
DIN RAIL
MOUNTING
CONTROLLERS
Passive 4... 20 mA PV
2Vdc
(note)
mV, V
L
H
RS485
Transmitter
2 wires
12Vdc
(note)
mA
Pt1000/NTC/PTC
DI2
(note)
Thermocouple
Pt100
THERMOSTATS
ANALOGUE
CONTROLLERS
3 wires
DI1
OP4
(note)
OP1
OP3 *
OP2 *
SPECIAL
CONTROLLERS
AND “CUSTOM”
T
P
PV
TERMINALS
C
E
L
Pin connector:
Stripped wire
1.4 mm - 0.055 in. max. L 5.5 mm - 0.21 in.
q
R
O
I
R
O
-
Neutral Line C NO
100... 240VAC/
Close
20... 30VDC
C
NO
C
NC NO
Open
Note: Terminal 4 can be programmed as:
- Digital Input (DI2) connecting a free of voltage contact between terminals 4 and 11
- 0... 12 V SSR Drive Output (OP4) connecting the load between terminals 4 and 11
- 12 Vdc (20 mA) transmitter power supply connecting the transmitter between terminals 4 and 1
DIMENSIONS
kr3
R
O
-
78
5
64
14
18
D
S
E
N
M
-
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
Alarms
Set Point
Signal retransmission
Serial communication
Baud rate
Working hours counters
Wattmeter function
EVOogreen
Programmer (optional)
Timer (optional)
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
PID single or double action, ON/OFF, ON/OFF with Neutral Zone
Autotuning and Selftuning algorithms, Overshoot control
3 alarms programmable as absolute, deviation, band
4 programmable Set Points
Measuring or Set Point retransmission
TTL (standard) + RS485 (optional), ModBus RTU protocol
1200… 38400 baud
A cumulative non-erasable counter and a second one resettable with alarm
Instantaneous power, time consumption
Stand-by mode of display, selectable
Up to 8 segments with guaranteed soak
Independent with 5 function modes
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
OUTPUTS
Analogue input
Transmitter
PAC SYSTEMS
Digital inputs
CODE
PREPROGRAMMED
SYSTEMS
Accuracy
KR3
VERSION
Controller
Controller + Timer
Controller + Timer + Programmer
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC, RTD, mA, V, mV/digital input 1
TC, NTC, PTC, mA, V, mV/digital input 1
OUT 1
Relay SPDT 4A
Vdc for SSR driving
0/4… 20 mA, 0/2... 10V galvanically isolated
(control and retransmission)
OUT 2
Relay SPST 2A
Vdc for SSR driving
Not available
OUT 3
Relay SPST 2A
Vdc for SSR driving
Not available
OUT 4
Digital input 2 or digital output or transmitter supply
RS485
Available
Not available
connection
Plug-in screw type
Plug-in screw type, fix part only
Clamp type
Fix screw type (standard)
PLC AND
OPERATOR
PANELS
Universal
Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F),
S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F)
Infrared sensors: J or K
Thermoresistances: 3 wires Pt 100 and 2 wires Pt 1000 (-200... 850°C/-328... 1562°F)
Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V
Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F),
S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F)
Infrared sensors: J or K
Thermistors: PTC KTY81-121 (-55... +150°C/-67... 302°F), NTC 103 AT2 (-50... +110°C/-58... 230°F)
Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V
± 0.5% span ±1 digit, (±1% span ±1 digit for T/c S type)
1 or 2 according to instrument’s part number
(the 2nd digital input is alternative to OUT 4)
kr3
To compose the part number, pls. choose one of the option for each variable
TIMERS
COUNTERS
POWER LIMITERS
INPUTS
CONNECTIONS
INDICATORS
Dual LED
KR3
Main display: 4 digit h 11.7 mm. 3 colours: red, green and amber
Secondary display: 4 green digit, h 7 mm
I/O MODULES
DISPLAY
SUPERVISION
HOW TO ORDER
FEATURES
28
•3 dynamic colour led display
•analogUE CONTROL OUTPUT
•8 segmentS PROGRAMMER / Timer
•WORKING hours counter
35
KR3
IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S
52
53
IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S
Up to 4 (K31 and K32)
Up to 2 (K38 and K39)
Auxiliary power supply
FUNCTIONAL
Control
PID functions
Multi Set Point
Program
Timer
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Keyboard
Mounting
Connections
ON/OFF, Neutral Zone, PID single and double action
PID H/C control with overshoot control, Selftuning and 2 Autotuning algorithms
Up to 4 pre-programmable Set Point
Up to 8 segments with guaranteed soak
Independent with 4 function modes
Set Point
-RS485 with ModBus-RTU (JBUS) protocol
TTL ModBus
1200… 38400 baud, programmable
-12 Vac/Vdc, 24 Vac/Vdc, 100… 240 Vac/Vdc ±10% (50/60 Hz)
6 VA approx.
78 x 35 mm - depth 64 mm
78 x 35 mm - depth 64 mm / 180 g approx.
or 78.5 mm with plug-in terminals / 180 g approx.
Mechanical
Mechanical
Mechanical
or “Sensitive Touch”
Flush in panel in 71 x 29 mm hole
Plug-in terminals or
Screw terminal block 2 x 1 mm²
Screw terminal block 2 x 1 mm²
IP 65, mounted on panel with gasket
0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F)
20… 85 RH% without condensation
Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1)
(*) K32: Capacitive Touch screen keyboard
DIN RAIL
MOUNTING
CONTROLLERS
THERMOSTATS
ANALOGUE
CONTROLLERS
S
T
P
F
L
H
C
E
I
V
k38 / k39
R
O
M
R
O
R
O
R
O
-
DIMENSIONS
k31 / k32 / k38 / k39
S
-
78
6
12.2
78
64
35
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac)
OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac)
or 12V ±20% 20 mA max. to drive SSR
or 12V ±20% 20 mA max. to drive SSR
OUT 3 and OUT 4: Relay SPST-NO (5A-AC1, 3A-AC3/250 Vac)
or 12V ±20% 20 mA max. to drive SSR
12 Vdc/20 mA max.
CODE
SPECIAL
CONTROLLERS
AND “CUSTOM”
Accuracy
Digital inputs
OUTPUTS
K31 / K32 / K38 / K39
keyboard
Mechanical
Sensitive-Touch (*) - K32 only
VERSION
Controller
Controller + Timer
Controller + Timer + Programmer
Power supply
12 Vac/Vdc
24 Vac/Vdc
100… 240 Vac
INPUT
TC,PT100,mV
TC,PTC,NTC,mV
0/4… 20mA
0… 1V, 0/1… 5V, 0/2… 10V
OUT 1
Relay SPDT 8A-AC1
Vdc for SSR driving
Mosfet output (K31 only)
OUT 2
Relay SPDT 8A-AC1
Vdc for SSR driving
Not available
OUT 3 (Solo K31 e K32)
Relay SPST-NO 5A-AC1
Vdc for SSR driving
Not available
OUT 4 (Solo K31 e K32)
Relay SPST-NO 5A-AC1
Vdc for SSR driving
Not available
Serial communication (K31 and K32)
RS485
TTL ModBus
PAC SYSTEMS
4 different configurations
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermoresistances: 3 wires Pt 100 (-200.. 850°C / -328... 1562°F)
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F)
and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F)
Linear signals 0/4… 20mA
Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V
±0.5% fs + 1 digit; tc S ±1% fs + 1 digit
2 for free voltage contacts
--
k31 / k32
To compose the part number, pls. choose one of the option for each variable
PREPROGRAMMED
SYSTEMS
INPUTS
CONNECTIONS
PLC AND
OPERATOR
PANELS
K39
Dual:
4 red and 4 green digit,
h 7mm
TIMERS
COUNTERS
POWER LIMITERS
K38
Single:
4 red digit, h 12 mm
+ 3 LEDs Bargraph
INDICATORS
K32
Dual:
4 red and 4 green digit,
h 7mm
SUPERVISION
Display
K31
Single:
4 red digit, h 12 mm
+ 3 LEDs Bargraph
28
DISPLAY
I/O MODULES
HOW TO ORDER
FEATURES
35
•Controller with independent
timer
•8 segments Programmer
•wattmeter function
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
k 31/32/38/39
ACCESSORIES
COMBUSTION
CONTROL
The dimensions are expressed in mm
54
55
24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz)
6 VA approx.
48 x 48 mm (1/16 DIN) - depth 98 mm / 180 g approx.
Flush in panel in 45 x 45 mm hole
Screw terminal block 2 x 1 mm²
IP 65, mounted on panel with gasket
0… 50°C (32… 122°F)/-30… 70°C (-22… 158°F)
20… 85 RH% without condensation
Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1)
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
ON/OFF, Neutral Zone, PID single and double action
PID H/C control with overshoot control, Selftuning and 2 Autotuning algorithms
Up to 4 pre-programmable Set Point
Up to 8 segments with guaranteed soak
Independent with 4 function modes
TTL ModBus
DIN RAIL
MOUNTING
CONTROLLERS
CODE
THERMOSTATS
ANALOGUE
CONTROLLERS
T
P
L
H
SPECIAL
CONTROLLERS
AND “CUSTOM”
K48/K49
VERSION
Controller
Controller + Timer
Controller + Timer + Programmer
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC,PT100,mV
TC,PTC,NTC,mV
0/4… 20mA
0… 1V, 0/1… 5V, 0/2… 10V
OUT 1
Relay SPDT 8A-AC1
Vdc for SSR driving
OUT 2
Relay SPDT 8A-AC1
Vdc for SSR driving
Not available
OUT 3/ digital INPUTS
Relay SPST-NO 5A-AC1
Vdc for SSR driving
2 digital inputs
Not available
C
E
I
V
R
O
R
O
-
DIMENSIONS
k48 / k49
R
O
D
-
9.5
48
98
AT
ST
SET
Out1 Out2
-
=
+
Out3 Out4
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
Auxiliary power supply
FUNCTIONAL
Control
PID functions
Multi Set Point
Program
Timer
Serial communication
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1 and OUT 2: Relay SPST-NO (8 A-AC1, 3 A-AC3 / 250 Vac)
or 12V ± 20% 20 mA max. to drive SSR
OUT 3: Relay SPST-NO (5 A-AC1, 3 A-AC3 / 250 Vac)
or 12V ± 20% 20 mA max. to drive SSR
12 Vdc/20 mA max.
K48 / k49
To compose the part number, pls. choose one of the option for each variable
PAC SYSTEMS
Up to 3
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermoresistances: 3 wires Pt 100 (-200.. 850°C / -328... 1562°F)
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F)
and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F)
Linear signals 0/4… 20mA
Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V
± 0.5 % fs + 1 digit; tc S ± 1% fs + 1 digit
2 for free voltage contacts, as alternative to OUT 3
CONNECTIONS
PREPROGRAMMED
SYSTEMS
Accuracy
Digital inputs
OUTPUTS
K49
Dual: 4 red and 4 green digit, h 7mm
PLC AND
OPERATOR
PANELS
4 different configurations
K48
Single: 4 red digit, h 12 mm + 3 LEDs Bargraph
TIMERS
COUNTERS
POWER LIMITERS
DISPLAY
Display
INPUTS
INDICATORS
HOW TO ORDER
FEATURES
44.5
•Controller with independent
timer
•8 segments Programmer
•wattmeter function
48
k 48/49
IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S
56
57
24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz)
6 VA approx.
4 DIN rail module, 70 x 84 mm - depth 60 mm / 230 g approx.
On OMEGA DIN A rail
Screw terminal block 2 x 1 mm²
IP 40
0… 50°C (32… 122°F)/-30… 70°C (-22… 158°F)
20… 85 RH% without condensation
Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1)
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
ON/OFF, Neutral Zone, PID single and double action
PID H/C control with overshoot control, Selftuning and 2 Autotuning algorithms
Up to 4 pre-programmable Set Point
Up to 8 segments with guaranteed soak
Independent with 4 function modes
Set Point
RS485 with ModBus-RTU (JBUS) protocol
1200… 38400 baud, programmable
DIN RAIL
MOUNTING
CONTROLLERS
CODE
THERMOSTATS
ANALOGUE
CONTROLLERS
T
P
SPECIAL
CONTROLLERS
AND “CUSTOM”
L
H
R
O
R
O
-
PAC SYSTEMS
C
E
I
V
DIMENSIONS
k85
70
R
O
-
1 2 3
4 5
27
6 7
21
12
8 9 10 11 12
Tun
S
-
Prg
Out1 Out2
-
=
+
Out3
D
13 14 15 16 17 18 19 20 21 22 23 24
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
Auxiliary power supply
FUNCTIONAL
Control
PID functions
Multi Set Point
Program
Timer
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1 and OUT 2: Relay SPDT (8 A-AC1, 3 A-AC3 / 250 Vac) or 12V ± 20% 20 mA max. to drive SSR
OUT 3: Relay SPST-NO (5 A-AC1, 3 A-AC3 / 250 Vac) or 12V ± 20% 20 mA max. to drive SSR
12 Vdc/20 mA max.
K85
VERSION
Controller
Controller + Timer
Controller + Timer + Programmer
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC,PT100,mV
TC,PTC,NTC,mV
0/4… 20mA
0… 1V, 0/1… 5V, 0/2… 10V
OUT 1
Relay SPDT 8A-AC1
Vdc for SSR driving
OUT 2
Relay SPDT 8A-AC1
Vdc for SSR driving
Not available
OUT 3/ Digital inputs
Relay SPST-NO 5A-AC1
Vdc for SSR driving
Not available
Serial communication
RS485
TTL ModBus
INPUT digitale
2 digital inputs
Not available
PREPROGRAMMED
SYSTEMS
Up to 3
K85
To compose the part number, pls. choose one of the option for each variable
PLC AND
OPERATOR
PANELS
Accuracy
Digital inputs
OUTPUTS
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermoresistances: 3 wires Pt 100 (-200.. 850°C / -328... 1562°F)
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F)
and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F)
Linear signals 0/4… 20mA
Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V
± 0.5 % fs + 1 digit; tc S ± 1% fs + 1 digit
2 for free voltage contacts
CONNECTIONS
TIMERS
COUNTERS
POWER LIMITERS
4 different configurations
K85
4 red digit, h 12 mm + 3 LEDs Bargraph
60
DISPLAY
Single
INPUTS
INDICATORS
HOW TO ORDER
FEATURES
45
•Controller with independent
timer
•8 segments Programmer
•wattmeter function
84
k85
IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S
58
59
24 Vac/Vdc, 100… 240 Vac/Vdc ±10% (50/60 Hz)
6 VA approx.
78 x 35 mm - depth 75.5 mm or 78.5 mm with plug-in terminals / 180 g approx.
On OMEGA DIN A rail
Plug-in terminals or Screw terminal block 2 x 1 mm²
0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F)
20… 85 RH% without condensation
Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1)
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
ON/OFF, Neutral Zone, PID single and double action
PID H/C control with overshoot control, Selftuning and 2 Autotuning algorithms
Up to 4 pre-programmable Set Point
Up to 8 segments with guaranteed soak
Independent with 4 function modes
Del Set Point
RS485 con protocollo ModBus-RTU (JBUS)
1200… 38400 baud, programmabile
DIN RAIL
MOUNTING
CONTROLLERS
CODE
THERMOSTATS
ANALOGUE
CONTROLLERS
T
P
SPECIAL
CONTROLLERS
AND “CUSTOM”
L
H
C
E
I
V
R
O
R
O
-
DIMENSIONS
k30
21.55
R
O
R
O
S
-
27.80
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
Auxiliary power supply
FUNCTIONAL
Control
PID functions
Multi Set Point
Program
Timer
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Operating / storage temperature
Operating humidity
Conformity
OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or 12V ±20% 20 mA max. to drive SSR
OUT 3 and OUT 4: Relay SPST-NO (5A-AC1, 3A-AC3/250 Vac) or 12V ±20% 20 mA max. to drive SSR
OUT 5: 12V ±20% 20 mA max. to drive SSR (always available on boartd)
12 Vdc/20 mA max.
K30
VERSION
Controller
Controller + Timer
Controller + Timer + Programmer
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC,PT100,mV
TC,PTC,NTC,mV
0/4… 20mA
0… 1V, 0/1… 5V, 0/2… 10V
OUT 1 / OUT 5 SSR (always on board)
Relay SPDT 8A-AC1
Vdc for SSR driving
OUT 2
Relay SPDT 8A-AC1
Vdc for SSR driving
Not available
OUT 3
Relay SPST-NO 5A-AC1
Vdc for SSR driving
Not available
OUT 4
Relay SPST-NO 5A-AC1
Vdc for SSR driving
Not available
Serial communication
RS485
TTL ModBus
PAC SYSTEMS
Up to 5
k30
To compose the part number, pls. choose one of the option for each variable
PREPROGRAMMED
SYSTEMS
Accuracy
Digital inputs
OUTPUTS
CONNECTIONS
PLC AND
OPERATOR
PANELS
4 different configurations
K30
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermoresistances: 3 wires Pt 100 (-200.. 850°C / -328... 1562°F)
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F)
and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F)
Linear signals 0/4… 20mA
Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V
±0.5% fs + 1 digit; tc S ± 1% fs + 1 digit
2 for free voltage contacts
87.50
INPUTS
TIMERS
COUNTERS
POWER LIMITERS
HOW TO ORDER
FEATURES
78.65
•Controller with independent
timer
•8 segments Programmer
•wattmeter function
77.31
k30
IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S
60
61
Up to 4
Auxiliary power supply
FUNCTIONAL
Control
PID functions
100… 240 Vac (-15...+10%) o 24Vac (-25...+12%) e 24Vdc (-15...+25%) (50/60Hz)
3VA max.
48 x 48 mm (1/16 DIN), depth 150 mm / 230 g approx.
Flush in panel in 45 x 45 mm hole
Screw terminal block M3 for cables with section 1 mm² (18AWG)
IP65
0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F)
5… 95% RH without condensation
EN 61010-1
RS485
SPECIAL FUNCTIONS
Not available
Programmer
INSTRUCTION MANUAL
Italian/English
Not available
FRONT FRAME COLOUR
Dark grey (std)
Dark grey shunt 0.1%
SPECIAL EXECUTION
Not available
On DIN rail
On DIN rail without display
Tropicalized
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
PID, ON/OFF
PID H/C control, Dead band, overshoot control, manual reset, cycle time, high and low limits,
max. control output speed rate, Soft-start, safety output, forcing output, Fuzzy Tuning, Adaptive Tuning
1 Loop with single/double action with or without programmer
Local + 2 stored Set points, only Remote, Local and Remote, Local with trim, Remote with trim, Time programmable
1 program, 16 segments, 1... 9999 cycles or continuous cycling (OFF)
Integrated, Bumpless operated from keyboard, digital inputs and serial communication
Motor travel time, motor minimum step
Measuring or Set Point retransmission
Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires
1200, 2400, 4800, 9600, 19200 bit/s, a 3 wires
Not available
Thermocouple
External
shunt 2.5W
Pt100
00
01
02
03
04
05
50
51
52
53
DIN RAIL
MOUNTING
CONTROLLERS
NO
100%
POT
C
0%
NO
Com.
NO
IL 2
C2
IL 1
V
NPN
TTL
C1
DIMENSIONS
m5
48
120
54
0
1
0
9
0
2
0
1
2
3
THERMOSTATS
ANALOGUE
CONTROLLERS
mA
SPECIAL
CONTROLLERS
AND “CUSTOM”
mV
48
10 max.
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
Operating modes
Set Point
Program
Auto/Man station
Servomotor control
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1 and OUT 2: Relay NO, 2A/250Vac for resistive loads or Triac 1A/250Vac for resistive loads
OUT 3: Relay NO, 2A/250Vac for resistive loads
OUT 4: Analogue in current: 0/4…20mA max. 750Ω/10V max./ voltage: 0…1/5/10V 500Ω / 20mA max.
(galvanically isolated) or 0…18Vdc, 20mA max. to drive SSR
+18Vdc ±20%, 30mA max. for external transmitter (2, 3 or 4 wires)
N
C
18Vdc OUT
1
2
4
5
OPTIONS
Not available
Potentiometer
Remote Set Point
CT input
Voltage for SSR driving/
Analogue output
Voltage for SSR driving/
Analogue output+
Remote Set point
Not available
Potentiometer
Remote Set Point
CT input
Voltage for SSR driving/
Analogue output
L
NO
PAC SYSTEMS
Digital inputs
OUTPUTS
RS485
3
5
PREPROGRAMMED
SYSTEMS
Auxiliary inputs (opt.)
CODE
PLC AND
OPERATOR
PANELS
Accuracy
M5
Power supply
100… 240 Vac
24 Vac/Vdc
OUT 1 and out 2
Relay/Relay
Relay/triac
Triac/Relay
Triac/triac
Serial communication
TIMERS
COUNTERS
POWER LIMITERS
Universal
Thermocouples: L/J (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F),
K (0…+1200°C / 32…+2192°F), S/R (0... +1600°C / 32...2912°F)
Thermoresistances: PT100 connection with 2 or 3 wires (-200... +600°C / -328... +1112°F)
Linear signals: 0/10... 50 mV; 0/4…20 mA
Infrared sensors or special ranges (custom)
0.25% ±1 digit (thermoelements) o 0.1% ±1 digit (for mA and mV)
Non isolated remote Set Point: current 0/4… 20mA or voltage 1…5/ 0…5/ 0…10V
Current Transformer for Heater Break function
Potentiometer position feedback measurement
2
m5
To compose the part number, pls. choose one of the option for each variable
INDICATORS
INPUTS
CONNECTIONS
OP2 OP1
Double
M5
Main display: 4 green digit, h 10 mm
Secondary display: 4 green digit, h 8 mm + 8 LEDs
CT
DISPLAY
I/O MODULES
HOW TO ORDER
FEATURES
OP4
(REM)
•process controller
•analogue control output
or servomotor output
•16 segments Programmer
OP3
m5
IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S
62
63
Digital inputs
OUTPUTS
Up to 6
Auxiliary power supply
Alarms
FUNCTIONAL
Control
PID functions
Servomotor control
Set Point
Program
Auto/Man station
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
PID, ON/OFF single or double action, Split range
PID H/C control, Dead band, overshoot control, manual reset, cycle time, high and low limits,
max. control output speed rate, Soft-start, safety output, forcing output, Fuzzy Tuning, Adaptive Tuning
PID algorithm for 3 position Servomotor: Increase/Stop/Decrease
according to: motor travel time, motor minimum step, Potentiometer
Local + 3 stored Set points, only Remote, Local and Remote, Local with trim, Remote with trim, programmable
(Remote Set Point mutally exclusive with frequency input)
4 programs, 16 segments, 1... 9999 cycles or continuous cycling (OFF)
Integrated, Bumpless operated from keyboard, digital inputs and serial communication
Measuring or Set Point retransmission
Isolated RS485 with ModBus-RTU (JBUS) protocol MASTER and SLAVE - RS 485 asynchronous/isolated, PROFIBUS DP protocol
RS 485 (MASTER or SLAVE) Up to 19.200 bit/s;
PROFIBUS DP Up to 12Mb/s max. distance 100m (12Mb/s)
C
NPN
100%
NO
POT
0%
REM
SP
1
5
V V
mA
mV
0
1
5
6
7
8
0
1
4
6
7
THERMOSTATS
ANALOGUE
CONTROLLERS
TTL
Thermocouple
mA
OP6
(opt.)
mA
N/C
IN2
(opt.)
External
shunt 2.5W
Pt100
DIMENSIONS
x5
48
110
0
4
0
9
96
0
2
10 max.
0
3
The dimensions are expressed in mm
q5
96
100… 240 Vac (-15...+10%) or 24Vac (-25...+12%) and 24Vdc (-15...+25%) (50/60Hz)
5VA max.
48 x 96 mm (1/8 DIN), depth 110 mm / 250 g approx.
96 x 96 mm (1/4 DIN), depth 110 mm / 500 g approx.
Flush in panel in 45 x 92 mm hole
Flush in panel in 92 x 92 mm hole
Screw terminal block M3 for cables with section 1 mm² (18AWG)
IP65
0… 50°C (32… 122°F) / -20…+70°C (-4… 158°F)
5… 95% RH without condensation
EN 61010-1
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
OUT 1 and OUT 2: Relay NO, 2A/250Vac or Triac, 1A/250Vac, for resistive loads
OUT 3: Relay SPDT, 2A/250Vac for resistive loads
OUT 4: Relay NO, 2A/250Vac for resistive loads
OUT 5 and OUT6: current: 0/4…20mA max. 750Ω/10V max. / voltage: 0…1/5/10V 500Ω / 20mA max.
or 0/24Vdc ±10% - 30mA max. to drive SSR
+24DC ±20% 30mA max. - for external transmitter
Up to 4 alarms programmable as high/low, band alarm, deviation, Loop Break, Sensor Break
3
5
SPECIAL
CONTROLLERS
AND “CUSTOM”
Auxiliary inputs
CODE
PAC SYSTEMS
Frequency
X5 / Q5
Power supply
100… 240 Vac
24 Vac/Vdc
OUT 1, out 2, out 3, out 4 and out 5
Relay-Relay-Relay-Relay-logic/analogue
Triac-triac-Relay-Relay-logic/analogue
Serial communication
Not available
Mathematical package (MP)
RS485 + MP
RS485 Slave+Master+MP
Profibus DP+MP
RS485 + Profibus DP+MP
OPTIONS
Not available
HZ input
OUT 6 analogue
OUT 6 analogue + Hz
OUT 6 analogue + 300Hz input - (X5 only)
SPECIAL FUNCTIONS
Not available
4 Programs 16 segments
INSTRUCTION MANUAL
Italian/English
Not available
FRONT FRAME COLOUR
Dark grey
Dark grey + shunt 0.1%
SPECIAL EXECUTION
Not available
Tropicalized
PREPROGRAMMED
SYSTEMS
Universal
Thermocouples: L/J/E (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F),
K/N (0…+1200°C / 32…+2192°F), S/R (0... +1600°C / 32...2912°F), B (0... 1800°C / 32...3272°F),
W3/W5 (0... 2000°C / 32... 3632°F)
Thermoresistances: PT100 connection with 2 or 3 wires (-200... +600°C / -328... +1112°F)
Linear signals: 0/4…20 mA, 0... 50mV/0... 300mV, 0/1... 5V/0... 10V Engineering units with or without decimal and square root extraction
Infrared sensors or special ranges (custom)
0...2000 Hz, 0...20000 Hz;
Remote Set Point not isolated (accuracy 0.1%)
Current 0/4…20 mA
Voltage 0/1... 5V/0... 10V
Potentiometer position feedback measurement
3 for voltage contacts
x5 / q5
To compose the part number, pls. choose one of the option for each variable
OPERATOR
PANELS
INPUTS
CONNECTIONS
TIMERS
COUNTERS
POWER LIMITERS
Q5
Main display (PV): 4 green digit, h 15 mm
Secondary display (SP): 4 green digit, h 12 mm
Third display (OUT): 4 green digit, h 9 mm
INDICATORS
Triple
X5
Main display (PV): 4 green digit, h 12 mm
Secondary display (SP): 4 green digit, h 7 mm
Third display (OUT): 4 green digit, h 7 mm
110
I/O MODULES
DISPLAY
DIN RAIL
MOUNTING
CONTROLLERS
HOW TO ORDER
FEATURES
96
10 max.
SUPERVISION
•controller with profibus dp
•Up to 6 OUTPUTS: 2 analogue
OUTPUTS and 4 Set Points
•programmer and mathematical
package
RS485
(Slave)
x5 / q5
IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S
ACCESSORIES
COMBUSTION
CONTROL
The dimensions are expressed in mm
64
65
din rail mounting controllers
Versatile and compact
A complete range of modules, which are open to the outside world with “Manager/Gateway”
and with a wide range of operator interfaces.
Modules plug and play for the control and the acquisition of analog and digital signals.
66
67
·
·
·
K30
·
K85
TLZ35
·
·
1
·
1
·
1
·
·
2
·
·
2
Single display 4 digit
Input
Number of inputs
Universal
J-K-S-R-T + IR + PTC-NTC
J-K-S-R-T + IR + Pt100
Digital
For CT
Relay or voltage for SSR drive outputs
Analogue current or voltage outputs
Measuring or Set Point retransmission
Power supply
12 Vac/Vdc
24 Vac/Vdc
100… 240 Vac
Control Loops
Control
1
·
2
·
1
1+2
·
·
2
4
1
·
2+2
5
4
·
·
·
1
·
1
·
2
·
·
·
1
·
·
·
1
·
·
·
·
·
·
·
·
·
·
·
·
1
·
4
·
·
·
1
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
RS485 ModBus Slave
Timer on board
Start up
Programmer
CE certification
UL approval
ON/OFF and PID
ON/OFF
Servomotor control
1
·
THERMOSTATS
ANALOGUE
CONTROLLERS
D2
SPECIAL
CONTROLLERS
AND “CUSTOM”
D3
PAC SYSTEMS
D1
PLC AND
OPERATOR
PANELS
Dimensions (mm)
78 x 35
22.5 x 99
1 DIN Module
70 x 84
4 DIN Modules
TIMERS
COUNTERS
POWER LIMITERS
FEATURES
PREPROGRAMMED
SYSTEMS
din rail mounting controllers
DIN RAIL
MOUNTING
CONTROLLERS
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
IND U S T R I A L A U T OM AT I O N | D IN R A IL MO U N T IN G CO N T R O L L E R S
68
69
IND U S T R I A L A U T OM AT I O N | D IN R A IL MO U N T IN G CO N T R O L L E R S
INDUSTRIAL
CONTROLLERS
d1 / d2 / d3
Control
PID functions
PID algorithm for Servomotor
Set Point
Special functions
Alarms
Alarm functions
Tuning
Auto/Man station
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Front indications
Dimensions / Weight
Mounting
Connections
Protection degree
Parameters access
Operating / storage temperature
Operating humidity
Conformity
-+24dc, ±20%, 30 mA max. - for external transmitter
1 Loop PID with overshoot control,
ON/OFF single and double action (Heat-Cool)
Double acquisitor,
2 loops PID with overshoot control
or ON/OFF single action
Dead band, overshoot control, manual reset, cycle time, max. control output speed rate, Soft-start, safety output
-Optional
-Local, Local + 2 stored, with tracking, Stand-by
Local, Local + 2 stored Stand-by
Timer, Start-up
-Up to 3
Up to 4
Sensor break, Latching/Blocking, Loop break, Heater break associated to the timer (if available)
Fuzzy Tuning One shot or Natural Frequency
Integrated, Bumpless operated from digital input and serial communication
Measuring or setpoint retransmission
--(reference value)
Isolated RS485 with Modbus RTU protocol
RS 485 (MASTER or SLAVE) 1200, 2400, 4800, 9600 bit/s 3 wires
24Vac (-25… +12%), 24Vdc (-15… +25%) / 50/60Hz
4VA max.
3 red LEDs for DO + 1 green LED for PWR/COM
4 red LED for DO +
1 green LED for PWR/COM
22.5 x 99 mm, depth 114.5 mm / 159 g approx.
On DIN A rail
Power supply and comms: 0.08… 1.5 mm² (AWG28-AWG16)
Inputs/Outputs: 0.2… 2.5 mm² (AWG24-AWG12)
IP20 (terminal block)
Tramite linea seriale e software di supervisione
0... 50°C (32… 122°F) / -20… 70°C (-4… 158°F)
5… 95 RH% without condensation
EN61010-1 (IEC1010-1)
0
1
2
3
3
4
5
5
OP3
NO
NO
OP1
OP2
RS485
NC
TTL
N
L
IL
Connector for
power supply and
serial
communications
bus (female)
OP4
NO
0... 5V
24V
NPN
24VDC
External
Shunt
2.5Ω
mV
5
mA
Pt100
d2
0
2
3
5
7
Plug with
termination
resistor for
serial comm.s
bus (male)
OP1
OP2
OP3
OP4
Configuration
and Supervision
Power supply
and serial
communications
bus connector
(female)
RS485
NC
N
L
0
2
0
9
0
2
mV
External
Shunt
2.5Ω
mA
IN2
NO
External
Shunt
2.5Ω
IN1
Pt100
mV
DIMENSIONS
NPN
mA
Plug with
termination
resistor for serial
communications
bus (male)
OP3
4…20mA
Pt100
Configuration
and Supervision
OP5
mA
NO
NO
OP1
OP2
RS485
OP4
NO
0... 5V
24V
NPN
N
L
IL
TTL
22.5
TTL
d3
NC
d1/ d2 / d3
24V
Power supply
switch
IL1
NO
0
3
24V
Power
supply
switch
Connector for
power supply
and serial
communications
bus (female)
24V
Power supply
switch
24VDC
mV
99
DIN RAIL
MOUNTING
CONTROLLERS
Plug with termination
resistor for serial
communications bus
(male)
Current
transformer
THERMOSTATS
ANALOGUE
CONTROLLERS
5
Configuration
and Supervision
NO
SPECIAL
CONTROLLERS
AND “CUSTOM”
CODE
PAC SYSTEMS
Outputs function
Auxiliary power supply
FUNCTIONAL
OUT 1 and OUT 2: Relay NO,
2A res./250Vac
(4A res./120Vac) / SSR, 1A res./250Vac,
logic not isolated 0/5 Vdc
OUT 3: Logic not isolated 0/5 Vdc
NOT
--
D1 / D2 / D3
Power supply
24 Vac/Vdc
OUT 1 e 2
Relay (D1 only)
Relay-Relay
Relay-Vdc for SSR driving (D2 only)
Triac (D1 only)
Vdc for SSR driving-Vdc for SSR driving (Solo D2)
Triac-triac (D2 only)
Triac-triac (D1 and D3 only)
Triac-Vdc for SSR driving (D2 only)
Serial communication
RS485
OPTIONS 1
Not available
Servomotor (D3 only)
Current transformer (D1 only)
Analogue Out (D3 only)
Servomotor + Analogue Out (D3 only)
SPECIAL FUNCTIONS (D1 and D3 only)
Not available
Start-up + Timer
INSTRUCTION MANUAL
Italian/English
Not available
OPTIONS 2
Shunt 1%
Shunt 0.1%
OPTIONS 3
Not available
Tropicalization
PREPROGRAMMED
SYSTEMS
Up to 4 (D1)
Up to 5 (D3)
Up to 3 (D2)
OUT 1 and OUT 2: Relay NO, 2A res./250Vac (4A res./120Vac)/SSR, 1A res./250Vac
OUT 3: Relay NO, 2A res./150Vac
OUT 4: Logic not isolated: 0...5 Vdc
OUT 5: (D3 only) 0/4… 20 mA, 15V max.
d1
To compose the part number, pls. choose one of the option for each variable
PLC AND
OPERATOR
PANELS
OUTPUTS
CONNECTIONS
TIMERS
COUNTERS
POWER LIMITERS
Digital inputs
D2
1
2
Thermocouples: L/J/E (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F),
K/N (0…+1200°C/32…+2192°F), S/R (0... +1600°C / 32...2912°F), B (0... 1800°C / 32... 3272°F),
Ni-NiMo (0... 1100°C / 32... 2012°F), W3, W5 (0... 2000°C / 32... 3632°F)
Thermoresistances: PT100 (-99.9... 300.0°C / -99.9... 572.0°F and -200... 600°C / -328... 1112°F)
Linear signals: 0/10...50 mV; 0/4...20 mA (shunt)
Infrared sensors or special ranges (custom)
Current transformer
-1 voltage digital input
1 voltage digital input
(+ 2 programmable)
External
Shunt
2.5Ω
mA
INDICATORS
Auxiliary input
D3
Pt100
SUPERVISION
Universal
D1
114.5
Note: these modules can be inserted into Profibus DP and DeviceNet nets, together with a DX module, with the possibility of automatic reconfiguration.
6.3
ACCESSORIES
The dimensions are expressed in mm
COMBUSTION
CONTROL
INPUTS
Number of inputs
I/O MODULES
HOW TO ORDER
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•1 or 2 loop controllers
•single or double action
•Up to 3 alarms + RS485 + ct INPUT
70
71
24 Vac/Vdc, 100… 240 Vac/Vdc ±10% (50/60 Hz)
6 VA approx.
78 x 35 mm - depth 75.5 mm or 78.5 mm with plug-in terminals / 180 g approx.
On OMEGA DIN A rail
Plug-in terminals or Screw terminal block 2 x 1 mm²
0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F)
20… 85 RH% without condensation
Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1)
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
ON/OFF, Neutral Zone, PID single and double action
PID H/C control with overshoot control, Selftuning and 2 Autotuning algorithms
Up to 4 pre-programmable Set Point
Up to 8 segments with guaranteed soak
Independent with 4 function modes
Del Set Point
RS485 con protocollo ModBus-RTU (JBUS)
1200… 38400 baud, programmabile
DIN RAIL
MOUNTING
CONTROLLERS
CODE
THERMOSTATS
ANALOGUE
CONTROLLERS
T
P
SPECIAL
CONTROLLERS
AND “CUSTOM”
L
H
C
E
I
V
R
O
R
O
-
DIMENSIONS
k30
21.55
R
O
R
O
S
-
27.80
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
Auxiliary power supply
FUNCTIONAL
Control
PID functions
Multi Set Point
Program
Timer
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Operating / storage temperature
Operating humidity
Conformity
OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or 12V ±20% 20 mA max. to drive SSR
OUT 3 and OUT 4: Relay SPST-NO (5A-AC1, 3A-AC3/250 Vac) or 12V ±20% 20 mA max. to drive SSR
OUT 5: 12V ±20% 20 mA max. to drive SSR (always available on boartd)
12 Vdc/20 mA max.
K30
VERSION
Controller
Controller + Timer
Controller + Timer + Programmer
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC,PT100,mV
TC,PTC,NTC,mV
0/4… 20mA
0… 1V, 0/1… 5V, 0/2… 10V
OUT 1 / OUT 5 SSR (always on board)
Relay SPDT 8A-AC1
Vdc for SSR driving
OUT 2
Relay SPDT 8A-AC1
Vdc for SSR driving
Not available
OUT 3
Relay SPST-NO 5A-AC1
Vdc for SSR driving
Not available
OUT 4
Relay SPST-NO 5A-AC1
Vdc for SSR driving
Not available
Serial communication
RS485
TTL ModBus
PAC SYSTEMS
Up to 5
k30
To compose the part number, pls. choose one of the option for each variable
PREPROGRAMMED
SYSTEMS
Accuracy
Digital inputs
OUTPUTS
CONNECTIONS
PLC AND
OPERATOR
PANELS
4 different configurations
K30
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermoresistances: 3 wires Pt 100 (-200.. 850°C / -328... 1562°F)
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F)
and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F)
Linear signals 0/4… 20mA
Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V
±0.5% fs + 1 digit; tc S ± 1% fs + 1 digit
2 for free voltage contacts
87.50
INPUTS
TIMERS
COUNTERS
POWER LIMITERS
HOW TO ORDER
FEATURES
78.65
•Controller with independent
timer
•8 segments Programmer
•wattmeter function
77.31
k30
IND U S T R I A L A U T OM AT I O N | D IN R A IL MO U N T IN G CO N T R O L L E R S
72
73
24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz)
6 VA approx.
4 DIN rail module, 70 x 84 mm - depth 60 mm / 230 g approx.
On OMEGA DIN A rail
Screw terminal block 2 x 1 mm²
IP 40
0… 50°C (32… 122°F)/-30… 70°C (-22… 158°F)
20… 85 RH% without condensation
Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1)
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
ON/OFF, Neutral Zone, PID single and double action
PID H/C control with overshoot control, Selftuning and 2 Autotuning algorithms
Up to 4 pre-programmable Set Point
Up to 8 segments with guaranteed soak
Independent with 4 function modes
Set Point
RS485 with ModBus-RTU (JBUS) protocol
1200… 38400 baud, programmable
DIN RAIL
MOUNTING
CONTROLLERS
CODE
THERMOSTATS
ANALOGUE
CONTROLLERS
T
P
SPECIAL
CONTROLLERS
AND “CUSTOM”
L
H
R
O
R
O
-
PAC SYSTEMS
C
E
I
V
DIMENSIONS
k85
70
R
O
-
1 2 3
4 5
27
6 7
21
12
8 9 10 11 12
Tun
S
-
Prg
Out1 Out2
-
=
+
Out3
D
13 14 15 16 17 18 19 20 21 22 23 24
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
Auxiliary power supply
FUNCTIONAL
Control
PID functions
Multi Set Point
Program
Timer
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1 and OUT 2: Relay SPDT (8 A-AC1, 3 A-AC3 / 250 Vac) or 12V ± 20% 20 mA max. to drive SSR
OUT 3: Relay SPST-NO (5 A-AC1, 3 A-AC3 / 250 Vac) or 12V ± 20% 20 mA max. to drive SSR
12 Vdc/20 mA max.
K85
VERSION
Controller
Controller + Timer
Controller + Timer + Programmer
Power supply
24 Vac/Vdc
100… 240 Vac
INPUT
TC,PT100,mV
TC,PTC,NTC,mV
0/4… 20mA
0… 1V, 0/1… 5V, 0/2… 10V
OUT 1
Relay SPDT 8A-AC1
Vdc for SSR driving
OUT 2
Relay SPDT 8A-AC1
Vdc for SSR driving
Not available
OUT 3/ Digital inputs
Relay SPST-NO 5A-AC1
Vdc for SSR driving
Not available
Serial communication
RS485
TTL ModBus
INPUT digitale
2 digital inputs
Not available
PREPROGRAMMED
SYSTEMS
Up to 3
K85
To compose the part number, pls. choose one of the option for each variable
PLC AND
OPERATOR
PANELS
Accuracy
Digital inputs
OUTPUTS
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermoresistances: 3 wires Pt 100 (-200.. 850°C / -328... 1562°F)
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F)
and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F)
Linear signals 0/4… 20mA
Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V
± 0.5 % fs + 1 digit; tc S ± 1% fs + 1 digit
2 for free voltage contacts
CONNECTIONS
TIMERS
COUNTERS
POWER LIMITERS
4 different configurations
K85
4 red digit, h 12 mm + 3 LEDs Bargraph
60
DISPLAY
Single
INPUTS
INDICATORS
HOW TO ORDER
FEATURES
45
•Controller with independent
timer
•8 segments Programmer
•wattmeter function
84
k85
IND U S T R I A L A U T OM AT I O N | D IN R A IL MO U N T IN G CO N T R O L L E R S
74
75
Relay operations
FUNctional
Control
Acoustic alarm
Defrosting control
GENERAL
Power supply
Power consumption
Dimensions / Weight
Connections
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
INDUSTRIAL
CONTROLLERS
ON/OFF
Internal buzzer (optional)
At intervals time by stopping compressor
12, 24 Vac/Vdc, 100… 240 Vac ± 10% (50/60 Hz)
3 VA approx.
4 DIN rail modules - 70 x 84 x 60 mm / 150 g approx.
Screw terminal block 2.5 mm²
On OMEGA DIN A rail
IP40, for internal use
0… +50°C (32… +122°F) /-25… +60°C (-13… +140°F)
30… 95 RH% without condensation
Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1)
Code
F
L
H
THERMOSTATS
ANALOGUE
CONTROLLERS
OUT 1: Relay SPST-NO 16A -AC1(6A-AC3)/250 Vac or SPDT 16A- AC1(6A-AC3)/250 Vac
OUT2: Relay SPDT 8A-AC1 (3A-AC3)/ 250 Vac
100000 operations for relay SPST-NO 16A and SPDT 8A - 50000 operations for relay SPDT 16A
TLZ35
Power supply
12 Vac/Vdc
24 Vac/Vdc
100… 240 Vac
OUT 1
Relay SPDT 16A-AC1
Relay SPST NO-16A-AC1
OUT 2
Relay
Not available
Buzzer (internal)
Available
Not available
S
R
SPECIAL
CONTROLLERS
AND “CUSTOM”
Up to 2
tlz35
To compose the part number, pls. choose one of the option for each variable
R
B
-
PAC SYSTEMS
Digital input
Accuracy
OUTPUTS
Termistori PTC KTY 81-121 (990Ω a 25°C) -50… +150°C (-58… +302°F) oppure
Termistori NTC 103AT-2 (10kΩ a 25°C) -50… +109°C (-58… +228°F)
1 digital input for free voltage contacts
± 0.5 % fs
COnnections
dimensions
PREPROGRAMMED
SYSTEMS
One
TLZ35
4 red digit, o blu, h 12 mm
tlz35
70
1 2 3
4 5
27
6 7
21
12
8 9 10 11 12
PLC AND
OPERATOR
PANELS
DISPLAY
Single
INPUT
DIN RAIL
MOUNTING
CONTROLLERS
how to order
features
ADVANCED
PROGRAMMER
CONTROLLERS
•THermostat
•1 inPUT AND UP TO 2 OUTPUTS
-
=
+
60
84
Prg
Out1 Out2
45
Tun
Out3
13 14 15 16 17 18 19 20 21 22 23 24
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
TIMERS
COUNTERS
POWER LIMITERS
tlZ35
IND U S T R I A L A U T OM AT I O N | D IN R A IL MO U N T IN G CO N T R O L L E R S
76
77
Thermostats analogue controllers
Simple, reliable and cost effective !
Digital thermostats in different sizes for every application and analog controllers
in the 1/16 DIN - 48 x 48 mm case.
78
79
Input
PTC-NTC
J-K
Pt100
Digital
Relay or voltage for SSR drive outputs
Power supply
Control
TLZ35
E51A
W09
TCPDE
·
·
·
·
·
3
·
·
·
4
·
4
·
4
·
3
·
3
·
·
·
·
·
·
·
1
·
·
1
·
·
2
·
·
2
·
·
·
·
1
·
1
1
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
THERMOSTATS
ANALOGUE
CONTROLLERS
TLZ11
·
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
TIMERS
COUNTERS
POWER LIMITERS
CE certification
UL approval
ENEC approval (with “Sensitive Touch” keyboard only)
12 Vac/Vdc
12… 24 Vac/Vdc
24 Vac/Vdc
115 Vac
230 Vac
24… 240 Vac
100… 240 Vac
ON/OFF
PD
TLZ10
·
SPECIAL
CONTROLLERS
AND “CUSTOM”
Single display
Digit
"Sensitive Touch" keyboard
Z31A
·
PAC SYSTEMS
Dimensions (mm)
78 x 35
68 X 35
48 x 48
75 x 122
70 x 84
4 DIN rail module
PREPROGRAMMED
SYSTEMS
features
PLC AND
OPERATOR
PANELS
thermostats - analogue controllers
DIN RAIL
MOUNTING
CONTROLLERS
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
IND U S T R I A L aut o m ati o n | T hE R MO S TAT s - A N A L O Gu e c o ntr o ll e rs
80
81
FUNCTIONAL
Control
Acoustic alarm
GENERAL
Power supply
Power consumption
Dimensions / Weight
Keyboard
Connections
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
INDUSTRIAL
CONTROLLERS
12 Vac/Vdc, 12...24 Vac/Vdc, 100...240 Vac ±10% (50/60 Hz)
4 VA approx.
78 x 35 mm - depth 64 mm or 75.5 mm with plug-in terminals / 120 g approx.
Mechanical or “Sensitive Touch”
Screw terminal block 2.5 mm² or plu-in connector with screw terminals 2.5 mm²
Flush in panel in 71 x 29 mm hole
IP65, mounted in panel with gasket
0… +50°C (32… +122°F) /-25… +60°C (-13… +140°F)
30… 95 RH% without condensation
Directive 2004/108/CE (EN55022: class B; EN61000- 4-2: 8KV air, 4KV cont.; EN61000-4-3: 10V/m;
EN61000-4-4: 2KV supply, inputs, outputs; EN61000-4-5: supply 2KV com. mode, 1 KV\ diff. mode;
EN61000-4-6: 3V), 2006/95/CE (EN 60730-1, EN 60730-2-7, EN 60730-2-9).
Regulation 37/2005/CE (EN13485 air, S, A, 2,- 50°C +90°C wheter used with NTC 103AT11 probe).
F
G
H
S
R
B
E
N
-
dimensions
z31a
B
78
(*) Capacitive Touch screen keyboard
DIN RAIL
MOUNTING
CONTROLLERS
THERMOSTATS
ANALOGUE
CONTROLLERS
S
6
12.2
78
64
35
Conformity
ON/OFF
Internal Buzzer (optional)
Code
SPECIAL
CONTROLLERS
AND “CUSTOM”
Relay electrical life
Z31A
keyboard
Mechanical
Sensitive-Touch (*)
Power supply
12 Vac/Vdc
12… 24 Vac/Vdc
100… 240 Vac
OUT 1
Relay SPDT 16A-AC1
Relay SPST NO-16A-AC1
Buzzer (internal)
Available
Not available
Connection
Plug-in screw type
Plug-in screw type, fix part only
Fix screw type (standard)
Display
Blue
Red (standard)
PAC SYSTEMS
One
OUT 1: Relay SPDT or SPST-NO (16A - 1HP 250V, 1/2HP 125 Vac);
EN 61810: 16 (9) A - EN 60730: 10 (4) A
UL 60730: 12 A Res., 30 LRA, 5 FLA
12 A max. for plug-in version
100000 operations for SPST-NO 16A and SPDT 8A relays
50000 operations for SPDT 16A relay
z31a / z31sa
To compose the part number, pls. choose one of the option for each variable
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
PREPROGRAMMED
SYSTEMS
Accuracy
OUTPUTS
PTC KTY 81-121 (990Ω at 25°C) -50… +150°C (-58… +302°F) or
NTC 103AT-2 (10kΩ at 25°C) -50… +109°C (-58… +228°F)
±0.5% fs + 1 digit
COnnections
28
One
Z31A
3 red or blue digit, h 15.5 mm
35
DISPLAY
Single
INPUTS
PLC AND
OPERATOR
PANELS
how to order
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•THermostat 1 inPUT AND 1 OUTPUT
•“Sensitive Touch” KEYBOARD
TIMERS
COUNTERS
POWER LIMITERS
Z31A
IND U S T R I A L aut o m ati o n | T hE R MO S TAT s - A N A L O Gu e c o ntr o ll e rs
82
83
Relay electrical life
FUNCTIONAL
Regolazione
Allarme acustico
Controllo sbrinamento
GENERAL
Power supply
Power consumption
Dimensions / Weight
Connections
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
INDUSTRIAL
CONTROLLERS
ON/OFF
Internal buzzer (optional)
At intervals time by stopping compressor
12, 24 Vac/Vdc, 100… 240 Vac ± 10% (50/60 Hz)
3 VA approx.
4 DIN rail modules - 70 x 84 x 60 mm / 150 g approx.
Screw terminal block 2.5 mm²
On OMEGA DIN A rail
IP40, for internal use
0… +50°C (32… +122°F) /-25… +60°C (-13… +140°F)
30… 95 RH% without condensation
Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1)
Code
F
L
H
THERMOSTATS
ANALOGUE
CONTROLLERS
OUT 1: Relay SPST-NO 16A -AC1(6A-AC3)/250 Vac or SPDT 16A- AC1(6A-AC3)/250 Vac
OUT 2: Relay SPDT 8A-AC1 (3A-AC3)/ 250 Vac
100000 operations for relay SPST-NO 16A and SPDT 8A - 50000 operations for relay SPDT 16A
TLZ35
Power supply
12 Vac/Vdc
24 Vac/Vdc
100… 240 Vac
OUT 1
Relay SPDT 16A-AC1
Relay SPST NO-16A-AC1
OUT 2
Relay
Not available
Buzzer (internal)
Available
Not available
S
R
SPECIAL
CONTROLLERS
AND “CUSTOM”
Up to 2
tlz35
To compose the part number, pls. choose one of the option for each variable
R
B
-
PAC SYSTEMS
Digital input
Accuracy
OUTPUTS
Thermistors PTC KTY 81-121 (990Ω at 25°C) -50… +150°C (-58… +302°F) or
Thermistors NTC 103AT-2 (10kΩ at 25°C) -50… +109°C (-58… +228°F)
1 digital input for free voltage contacts
± 0.5 % fs
COnnections
dimensions
PREPROGRAMMED
SYSTEMS
One
TLZ35
4 red digit, o blu, h 12 mm
tlz35
70
1 2 3
4 5
27
6 7
21
12
8 9 10 11 12
PLC AND
OPERATOR
PANELS
DISPLAY
Single
INPUT
DIN RAIL
MOUNTING
CONTROLLERS
how to order
features
ADVANCED
PROGRAMMER
CONTROLLERS
•THermostat
•1 inPUT AND UP TO 2 OUTPUTS
-
=
+
60
84
Prg
Out1 Out2
45
Tun
Out3
13 14 15 16 17 18 19 20 21 22 23 24
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
TIMERS
COUNTERS
POWER LIMITERS
tlZ35
IND U S T R I A L aut o m ati o n | T hE R MO S TAT s - A N A L O Gu e c o ntr o ll e rs
84
85
Relay electrical life
FUNctional
Control
GENERAL
Power supply
Power consumption
Dimensions / Weight
Connections
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
INDUSTRIAL
CONTROLLERS
ON/OFF
12 Vac/Vdc, 115, 230 Vac ±10% (50/60 Hz)
3 VA approx.
68 x 35 mm - depth 50 mm / 105 g approx.
Screw terminal block 2.5 mm²
Flush in panel in 58 x 25 mm hole
IP65, mounted in panel with gasket
0… +50°C (32… +122°F) / -25… +60°C (-13… +140°F)
30… 95 RH% without condensation
Directive 2004/108/CE (EN55022: class B; EN61000- 4-2: 8KV air, 4KV cont.;
EN61000-4-3: 10V/m; EN61000-4-4: 2KV supply, inputs, outputs;
EN61000-4-5: supply 2KV com. mode, 1 KV\ diff. mode; EN61000-4-6: 3V),
2006/95/CE (EN 60730-1, EN 60730-2-7, EN 60730-2-9)
Code
F
C
D
THERMOSTATS
ANALOGUE
CONTROLLERS
OUT 1: Relay SPDT or SPST-NO (16A-AC1, 6A-AC3 250 Vac, 1 HP 250 Vac, 1/2HP 125 Vac);
12 A max. for plug-in version
100000 operations for relay SPST-NO 16A and SPDT 8A,
50000 operations for relay SPDT 16A
E51A
Power supply
12 Vac/Vdc
115 Vac
230 Vac
Input
PTC
NTC
OUT 1
Relay SPDT 16A-AC1
Relay SPST-NO-16A-AC1
P
N
SPECIAL
CONTROLLERS
AND “CUSTOM”
One
e51a
To compose the part number, pls. choose one of the option for each variable
S
R
PAC SYSTEMS
Accuracy
Output
PTC KTY 81-121 (990Ω at 25°C) -50… +150°C (-58… +302°F) or
NTC 103AT-2 (10kΩ at 25°C) -50… +109°C (-58… +228°F)
±0.5% fs + 1 digit
COnnections
dimensions
PREPROGRAMMED
SYSTEMS
One
E51A
3 red or blue digit, h 14 mm
e51a
65
5
50
PLC AND
OPERATOR
PANELS
DISPLAY
Display
INput
DIN RAIL
MOUNTING
CONTROLLERS
how to order
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•Thermostat
•1 input and 1 output
•small dimensions
E 51 A
33
24.5
OUT
SET
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
TIMERS
COUNTERS
POWER LIMITERS
e51a
IND U S T R I A L aut o m ati o n | T hE R MO S TAT s - A N A L O Gu e c o ntr o ll e rs
86
87
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
INDUSTRIAL
CONTROLLERS
ON/OFF
At intervals time by stopping compressor
Internal Buzzer (optional)
100...240 Vac ±10% (50/60 Hz)
3 VA approx.
75 x 122 mm - depth 34 mm / 120 g approx.
Screw terminal block for cables 0.2...1.5 mm² / AWG 24...16
On wall.
Cables outlet: on the back side or lateral side by PG9 cable gland
IP40
0… +50°C (32… +122°F) / -25… +60°C (-13… +140°F)
30… 95 RH% without condensation
Directive 2004/108/CE (EN55022: class B; EN61000- 4-2: 8KV air, 4KV cont.; EN61000-4-3: 10V/m;
EN61000-4-4: 2KV supply and relay outputs, 1KV inputs; EN61000-4-5: supply 2KV com. mode, 1 KV\ diff. mode;
EN61000-4-6: 3V); Directive 2006/95/CE (EN 60730-1, EN 60730-2-9).
Regulation 37/2005/CE (EN13485 air, S, A, 2,- 50°C +90°C wheter used with NTC 103AT11 probe).
Regulation 37/2005/CE (EN13485 air, S, A, 2,- 50°C +90°C wheter used with NTC 103AT11 probe).
Code
THERMOSTATS
ANALOGUE
CONTROLLERS
H
R
B
-
SPECIAL
CONTROLLERS
AND “CUSTOM”
FUNCTIONAL
Control
Defrosting control
Acoustic alarm
GENERAL
Power supply
Power consumption
Dimensions / Weight
Connections
OUT1: Relay SPDT 8A, 1/2HP 250V, 1/3 HP 125 Vac
- EN 61810: 8 (3) A
- EN 60730: 8 (4) A
- UL 60730: 10A Res., 12 LRA, 2 FLA
W09
POWER SUPPLY
100… 240Vac
OUT 1
Relay SPDT-8A-AC1
Buzzer (internal)
Available
Not available
Connection
Screw type
Display
Blue
Red (standard)
B
-
PAC SYSTEMS
One
w09
To compose the part number, pls. choose one of the option for each variable
DIMENSIONS
w09
75
34
PREPROGRAMMED
SYSTEMS
Accuracy
OUTPUTS
Thermistors PTC KTY 81-121 (990Ω at 25°C) -50… +150°C (-58… +302°F)
or Thermistors NTC 103AT-2 (10kΩ at 25°C) -50… +109°C (-58… +228°F)
±0.5% fs + 1 digit
CONNECTIONS
PLC AND
OPERATOR
PANELS
One
W09
3 red or blue digit, h 15.5 mm
122
DISPLAY
Single
INPUTS
DIN RAIL
MOUNTING
CONTROLLERS
how to order
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•Thermostat 1 INPUT and 1 output
•wall Mounting
16
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
TIMERS
COUNTERS
POWER LIMITERS
w09
IND U S T R I A L aut o m ati o n | T hE R MO S TAT s - A N A L O Gu e c o ntr o ll e rs
88
89
INDUSTRIAL
CONTROLLERS
24… 240 Vac ±10% (50/60 Hz)
3 VA approx.
48 x 48 mm (1/16 DIN) - depth 89 mm / 200 g approx.
Faston 6.3 mm terminals or Octal socket
Flush in panel in 45.5 x 45.5 mm hole
IP 54, mounted on panel with gasket
0… +50°C (32… +122°F) / -25… +60°C (-13… +140°F)
30… 95 RH% without condensation
Directive EMC 2004/108/CE (EN 61326), Directive BT 2006/95/CE (EN 61010-1)
DIN RAIL
MOUNTING
CONTROLLERS
CODE
SPECIAL
CONTROLLERS
AND “CUSTOM”
THERMOSTATS
ANALOGUE
CONTROLLERS
1
2
3
4
6
7
8
9
U
J
K
P
PAC SYSTEMS
GENERAL
Power supply
Power consumption
Dimensions / Weight
Connections
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
ON/OFF, PD
Ranges available from 100 to 1200°C:
0… 100°C (Pt100 only)
0… 200°C
0… 250°C
0… 350°C
0… 600°C
0… 1000°C
0… 1100°C
0… 1200°C
TCPDE m
ranges
0… 100°C (PT100 only)
0… 200°C
0… 350°C
0… 600°C
0… 1000°C
0… 1200°C
0… 250°C
0… 1100°C
Power supply
24… 240 Vac
INPUT
J
K
PT100
output
Relay
0… 12 V for SSR driving
wiring diagram
Thermocouples
Thermoresistances (*)
Thermocouples
Thermocouples
Thermocouples
Connections
Faston
Octal
control
ON/OFF
PD
tcpde M - pt100 INPUT
R
T
PREPROGRAMMED
SYSTEMS
Ranges
OUT 1: Relay 8A-AC1 (3A-AC3)/250Vac or 20 mA/12 Vdc to drive SSR
tcpde M - tc INPUT
To compose the part number, pls. choose one of the option for each variable
31
32
33
34
35
PLC AND
OPERATOR
PANELS
Accuracy
OUTPUT
One
FUNCTIONAL
Control
CONNECTIONS
F
O
O
P
TIMERS
COUNTERS
POWER LIMITERS
2 different configurations
TCPDE m
Thermocouples J, K
Thermoresistances Pt 100 IEC
±5% f.s.
DIMENSIONS
tcpde M
(*) max. range for PT100 input: 350°C
48
48
11
INDICATORS
INPUTS
6
T
Faston
TCPDE
70
11
6
15
3
5
10
Octal
70
18
I/O MODULES
how to order
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•analogue controller
•ON/OFF and PD control
•ranges from 100 to 1200°C
SUPERVISION
tcpde m
IND U S T R I A L aut o m ati o n | T hE R MO S TAT s - A N A L O Gu e c o ntr o ll e rs
ACCESSORIES
COMBUSTION
CONTROL
The dimensions are expressed in mm
90
91
special controllers
and “custom”
The only limit is your imagination...
Our production program includes many models that can be used in specific applications such
as controllers for Peltier cells, differential controllers, controllers dedicated to the bakery sector
and also “custom” products to meet specific customer requirements.
92
93
IND U S T R I A L A U T OM AT I O N | S P EC I A L CO N T R O L L E R S A ND “c ust o m”
SPECIAL controllers and “custom”
FEATURES
Dimensions (mm)
TCO30
78 x 35
72 x 144
Single display
Triple display
Digit
Inputs
·
·
J-K
Pt100 2 wires
TC J,K,S, IR + PT100
TC J,K,S, IR + PTC, NTC
0/4… 20mA
0/10… 50mV, 0/12… 60mV,
0/1… 5V, 0/2… 10V
Relay outputs
Voltage output 12… 24 Vdc and Vdc for SSR driving (10mA/Vdc)
24, 115, 230 Vac
Power supply
12… 24 Vdc
ON/OFF
Peltier
cells:
PID double action,
Control
Autotuning FAST, Selftuning,
Fuzzy overshoot control
RS485
8 programs
CE certification
UL approval
94
TLK33
·
·
3+3+4
·
·
4
·
·
·
·
7
2
·
·
·
·
·
·
·
·
·
95
Approx. 7 years by means of internal battery
RS485 isolated, ModBus RTU
2400… 38400 baud
24, 115, 230 Vac ± 10% (50/60 Hz)
9 VA approx.
72 x 144 mm, depth 77 mm / 600 g approx.
Flush in panel in 68 x 139 mm hole
Screw terminal block 2.5 mm²
0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F)
20… 95 RH% without condensation
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
ON/OFF
8 cooking programs
DIN RAIL
MOUNTING
CONTROLLERS
CODE
D
C
D
C
A
A
R
V
-
DIMENSIONS
tco30
S
72
9
68
I
-
144
FUNCTIONAL
Control
Programs
Internal clock lifetime memory
without power supply
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Operating / storage temperature
Operating humidity
OUT STEAM: 1 Relay SPST-NO (16 A-AC1, 6 A-AC3 / 250 Vac)
Other OUTS: Relay SPST-NO (8 A-AC1, 3 A-AC3 / 250 Vac)
TCO30
INPUT
PT100
J-K
Power supply
230 Vac
115 Vac
24 Vac
auxiliary probe input
Available
Not available
AUXILIARY OUTPUT
Available
Not available
STEAM PROBE INPUT
Relay
Vdc for SSR driving
Serial communication
RS485
Not available
3 Digital inputs
Available
Not available
THERMOSTATS
ANALOGUE
CONTROLLERS
Up to 7
Thermocouples: J/K (-50 ... +999 °C/-58 …+999 °F)
Thermoresistances: Pt 100 2 wires (-50... +600°C/-58… +999°F)
3, for free voltage contacts
tco30
To compose the part number, pls. choose one of the option for each variable
SPECIAL
CONTROLLERS
AND “CUSTOM”
INPUTS
Up to 4:
Top, Floor, Steamer and auxiliary probe
Digital inputs
OUTPUTS
CONNECTIONS
PAC SYSTEMS
Triple
TCO30
2 temperature indications: 3 red digit, h 14 mm
1 time indication: 4 red digit, h 7 mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
PREPROGRAMMED
SYSTEMS
DISPLAY
PLC AND
OPERATOR
PANELS
HOW TO ORDER
FEATURES
TIMERS
COUNTERS
POWER LIMITERS
•Controller for cooking ovens
•up to 8 programs
•Up to 4 INPUTS for top, floor
steamer and Auxiliary probe
135
TCO30
IND U S T R I A L A U T OM AT I O N | S P EC I A L CO N T R O L L E R S A ND “c ust o m”
96
97
IND U S T R I A L A U T OM AT I O N | S P EC I A L CO N T R O L L E R S A ND “c ust o m”
INDUSTRIAL
CONTROLLERS
peltier cells
controller
DIN RAIL
MOUNTING
CONTROLLERS
0..50/60 mV
0/1..5 V
0...1 V
0/2..10 V
0/4..20 mA ACTIVE
4..20 mA
PASSIVE
(2 wires)
4..20 mA
ACTIVE
OUT 12 VDC
Max 20 mA
PTC-NTC
RS 485
DIG
IN2
DIG
IN1
B
GND
A
+
Pt100
2
3
4
5
6
7
8
9 10 11 12
SPECIAL
CONTROLLERS
AND “CUSTOM”
1
INPUT
SSR:10mA/10VDC
TLK 33
O
13 14 15 16 17 18 19 20 21 22 23 24
C
S
-
AL1
AL2
PELTIER MODULE
+ HEAT 7A MAX.
dimensions
tlk33
I
-
TLK33 : When the RS485 is required, 2 digital inputs are always on board too.
+ COOL
78
6
12.2
28
O
-
SUPPLY
12..24 VDC
PAC SYSTEMS
O
-
78
64
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
PREPROGRAMMED
SYSTEMS
TC/mV
PLC AND
OPERATOR
PANELS
D
E
I
V
ext.
gen.
THERMOSTATS
ANALOGUE
CONTROLLERS
G
35
12… 24 Vdc ±10%
4 VA approx.
78 x 35 mm - depth 75.5 mm / 130 g approx.
Screw terminal block 2.5 mm²
Flush in panel in 71 x 29 mm hole
IP65, mounted in panel with gasket
0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F)
20… 85 RH% without condensation
Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1)
Code
35
PID dual action, Autotuning FAST, Selftuning algorithms, Fuzzy overshoot control
4 Set Points programmable
RS485 with Modbus RTU protocol
1200… 38400 baud, programmable
TLK33
power supply
12… 24 Vdc
InPUT
PT100 + TC (J,K,S,IRS), mV
PTC,NTC,mV + TC (J,K,S,IRS)
0/4… 20mA
0/1… 5V, 0/2… 10V
control oOUTPUTS ( 2 FOR SSR )
12… 24 Vdc for Peltier cells (7A max)
OUT AL1
Vdc for SSR driving
Not available
OUT AL2
Vdc for SSR driving
Not available
serial Communication
RS485 + 2 digital inputs
Not available
digital INPUT
Available
Not available
+
12… 24 Vdc (equal to power supply) to direct drive Peltier cells max. 7A;
up to 2 alarm outputs in voltage for SSR driving (10mA/ 10Vdc)
12 Vdc / 20 mA max.
tlk33
To compose the part number, pls. choose one of the option for each variable
-
Digital inputs
Accuracy
OUTPUTS
Up to 2, in voltage to direct drive
Peltier cells
Auxiliary supply
FUNctional
Control
Set Point
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Connections
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
Thermocouples (0... 1000°C/32... 1832°F), K (0… 1370°C/32... 2498°F), S,R (0… 1760°C/32... 3200°F),
T (0... 400°C/32… 752°F) and Infrared sensors J or K type +
Thermoresistances Pt 100 3 wires (-200.. 850°C/-328... 1562°F)
Thermocouples J (0... 1000°C/32... 1832°F), K (0… 1370°C/32... 2498°F), S,R (0… 1760°C/32... 3200°F),
T (0... 400°C/32… 752°F) and Infrared sensors J or K type +
Thermistors PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C/-67... 302°F)
and Thermistors NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C/-58... 230°F)
Linear signals 0/4… 20mA
Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V
2 digital inputs for free voltage contacts
± 0,5% span ±1 digit, Tc S :±1% span ±1 digit
COnnections
I
4 different configurations
TLK33
4 red digit, h 12 mm
+
+
DISPLAY
Single
INPUTS
TIMERS
COUNTERS
POWER LIMITERS
how to order
features
ADVANCED
PROGRAMMER
CONTROLLERS
•PID control
•up to 2 outputs
•RS485
98
99
pac systems
The right solution for every
application!
New generation of programmable controllers (PAC - Programmable Automation Controller).
They manage the control, the monitoring and permit the remote control of machines and
small industrial plants.
Within Sigma2 line, two hardware solutions are available: one modular and distributed
(SigmaPAC: CU02) and one compact (MicroPAC: M81, MP02).
100
101
pac systems
Power supply
Control
ON/OFF, PID con Autotuning avanzato
Controllo Attuatori motorizzati
Processor ARM 32 bit
16 MB RAM, 2MB program and 64 KB flash
USB port
Real Time Clock
Ethernet port (communication, programming, configuration)
RS485 port
RS232 port
Modbus RTU (Master/Slave) protocol, Modbus TCP Server, ASCII
Profibus DP
Programming languages : IL, ST, FBD, LD, SFC, CFC
Advanced libraries dedicated to process control
CE certification
UL approval (listed)
(*) with expansion units - see hereunder models
1
1
8+32 (*)
4
2
·
·
4
·
·
·
·
·
·
·
·
·
1
·
·
·
·
·
·
·
·
·
·
·
·
1
·
·
·
·
·
·
·
·
·
·
2
·
·
·
·
·
·
SPECIAL
CONTROLLERS
AND “CUSTOM”
6+2
8 + 32 (*)
2
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
Digital expansion units:
MPD10808 (8 inputs 24 Vdc + 8 outputs 24 Vdc, 0.5A)
MPD11616 (16 inputs 24 Vdc + 16 outputs 24 Vdc, 0.5A)
MPD20808 (8inputs 24 Vdc + 8 relays outputs 2A)
MPD40808 (8 inputs 120 Vac + 8 relays outputs 2A)
THERMOSTATS
ANALOGUE
CONTROLLERS
2
8
4
12
10
24 Vac/Vdc
24 Vdc
·
PAC SYSTEMS
Relay or voltage outputs
Analogue outputs (current or voltage)
Analogue outputs (voltage only)
·
PREPROGRAMMED
SYSTEMS
Inputs
(16 bit)
CU02
PLC AND
OPERATOR
PANELS
Ingresso universale
NTC-PT1000
0/4… 20 mA, 0/1… 5V, 0… 10V
Digitali
Potenziometro
Raziometrico (5V)
MP02
TIMERS
COUNTERS
POWER LIMITERS
Dimensions (mm)
M81
·
INDICATORS
10 moduli DIN (175 x 110 mm)
8 moduli DIN (152 x 110 mm)
I/O MODULES
features
DIN RAIL
MOUNTING
CONTROLLERS
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
IND U S T R I A L A U T OM AT I O N | PA C S Y S T EM S
102
103
4 Analogue
10 Digital
functional
Processor
Memory
Programming languages
Standard
Real time clock
Minimum time of cycle execution
Serial ports
Protocols
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
ARM 32 bit
16 MB of RAM system, application memory max. 2 MB internal + 3.5 MB on USB key
64 kB redundant FLASH memory
IL, ST, FBD, LD, SFC, CFC
IEC61131-3
on board
10ms
Ethernet + RS485 + RS232/485
Modbus RTU (Master/Slave), Modbus TCP Server, ASCII
24 Vac/Vdc (-15... +25%) (50/60 Hz)
13 VA (+6.5 VA with I/O modules)
175 x 110 mm, depth 60 mm / 450 g approx.
On OMEGA DIN A rail
IP 20
0… 50°C (32… 122°F) / -40…+70°C (-40… 158°F)
5… 95 RH% without condensation
5
R
O
Q
DIN RAIL
MOUNTING
CONTROLLERS
PC
TABLET
HMI
CELL
PHONES
USB KEY
MODEM
Remote I/O
ROUTER
INPUTS
M81
R
O
Q
OUTPUTS
REMOTE
SUPERVISOR
R
V
-
dimensions
m81
U
1
2
110
M81
60
175
E
N
60
Rail mounting
DIN 35 x 7.5
(EN 50022)
The dimensions are expressed in mm
CABLES
Ethernet CABLE 2m, programm. CU,
PC-RJ45/CU-RJ45
POWER ADAPTOR 3.2 A
POWER ADAPTOR 5 A
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
POWER ADAPTORS
APS2 ALDR75-24
APS2 ALDR12024
internet
cloud
THERMOSTATS
ANALOGUE
CONTROLLERS
Code
accessories
APS2 CABLECUPROG
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
4x 0... 10 V
Resolution 16 bit
Accuracy: 0.5% of span
Load >1kΩ
Insulation 800 V between power supply and logic
10 relay digital outputs channels (2 relays SPDT-5A, 8 relays SPST-NO 2A)
Insulation 2500V channels to power supply and channels to logic
M81
analogue inputs
0/4… 20mA
0/5 Volt, ratiometrics
OUT 1
Relay SPDT 5A
Vdc for SSR driving
SSR 2A 250 Vac
OUT 2
Relay SPDT 5A
Vdc for SSR driving
SSR 2A 250 Vac
OUT 7…10
Relay SPST 2A
Not available
analogue outputs 1…4
0… 10V
Not available
USB port
Available
Not available
communication ports
COM 1 RS485/232
COM1 RS485/232 + COM2 RS485
reserved part no.
connections
Plug-in screw type
Plug-in screw type, fix part only
SPECIAL
CONTROLLERS
AND “CUSTOM”
outputs
m81
To compose the part number, pls. choose one of the option for each variable
PAC SYSTEMS
12 Digital
COnnections
PREPROGRAMMED
SYSTEMS
12 Analogue
M81
8x Thermistors NTC 103AT-2, Thermoresistances Pt1000 and
4x Linear signals 0/1... 5V, 0/2… 10V, 0/4... 20 mA, ratiometrics
Resolution: 16 bit
Accuracy: 0.5% of span
Input impedance >100kΩ (V); 300Ω (mA)
Insulation 2500V channels to power supply and channels to logic (High level analogue signals)
Insulation 800 V between power supply and logic (Sensors)
12 digital inputs for free voltage contacts
Insulation 800 V between power supply and logic
Compliant to IEC/EN 61131-2 (type 1)
PLC AND
OPERATOR
PANELS
inputs
TIMERS
COUNTERS
POWER LIMITERS
how to order
features
INDICATORS
•compact PROGRAMMABLE
controller (micropac)
•8 + 4 A/i
•12 d/i + 10 d/o
•4 a/o
I/O MODULES
m81 sigma2
IND U S T R I A L A U T OM AT I O N | PA C S Y S T EM S
104
105
Memory
Programming languages
Standard
Real time clock
Execution cycle Minimum time
Serial ports
Protocols
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
24 Vdc (-15... +25%) / 50/60 Hz
13 VA (+3.5 VA with both expansion units)
152 x 110 mm, depth 66 mm / 460 g approx.
On OMEGA DIN A rail
IP 20
0… 50°C (32… 122°F) / -40…+70°C (-40… 158°F)
5… 95 RH% without condensation
Note: MP02 unit can be expanded up to 2 I/O modules through the side connector and via one of the RS485 ports by using the Modbus I/O modules.
DIN RAIL
MOUNTING
CONTROLLERS
THERMOSTATS
ANALOGUE
CONTROLLERS
internet
cloud
CELL
PHONES
ROUTER
INPUTS
REMOTE
SUPERVISOR
OUTPUTS
-
dimensions
PREPROGRAMMED
SYSTEMS
-
PAC SYSTEMS
0
1
2
mp02
2
-
65.8
M
76
45.2
152
20.6
22
accessories
The dimensions are expressed in mm
CABLES
APS2 CABLECUCONF
APS2 CABLECUPROG
POWER ADAPTORS
APS2 ALDR75-24
APS2 ALDR12024
filters
APS2 FILTRI
PLUGS
APS2 SPINAM11
APS2 SPINAV11
APS2 SPINAM14
APS2 SPINAV14
RS232 CABLE 2m, config. CU,
PC-DB9F/CU-RJ45
Ethernet CABLE 2m, programm. CU,
PC-RJ45/CU-RJ45
POWER ADAPTOR 3.2 A
POWER ADAPTOR 5 A
FERRITES + FILTERS
PLUG WITH 11 polE CLAMP TERMINALS
PLUG WITH 14 polE SCREW TERMINALS
PLUG WITH 11 polE CLAMP TERMINALS
PLUG WITH 14 polE SCREW TERMINALS
PLC AND
OPERATOR
PANELS
-
MODEM
Remote I/O
SPECIAL
CONTROLLERS
AND “CUSTOM”
HMI
ACCESSORIES
Digital expansion units:
MPD10808 (8 inputs 24 Vdc + 8 outputs 24 Vdc, 0.5A)
MPD11616 (16 inputs 24 Vdc + 16 outputs 24 Vdc, 0.5A)
MPD20808 (8inputs 24 Vdc + 8 relays outputs 2A)
MPD40808 (8 inputs 120 Vac + 8 relays outputs 2A
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
ARM 32 bit
16 MB of RAM system, application memory max. 2 MB internal,
64 kB redundant FLASH memory
IL, ST, FBD, LD, SFC, CFC
IEC61131-3
on board
≥5ms (10ms tipical)
Ethernet + RS485 + RS232/485
Modbus RTU (Master/Slave), Modbus TCP Server, ASCII
TABLET
TIMERS
COUNTERS
POWER LIMITERS
functional
Processor
PC
INDICATORS
8+32 Digital
0
1
2
I/O MODULES
0/2/4 analogue
±10 V (±25 mA max.), 0/4... 20 mA
Resolution: 13 bit
Accuracy: 0.1% of span
Insulation 800 V between power supply and logic
8 + 32 (with expansion units) 24Vdc, 0.5 A or 8 + 8/16 relays (2A, 240 Vac, NA)
Source type (PNP)
Protection: Reverse polarity and short circuit
Insulation 800V between channels and power supply
Code
SUPERVISION
outputs
MP02
analogue inputs
6 ch - 0/4… 20mA, Volt
8 ch - 0/4… 20mA, Volt
6 ch - 0/4… 20mA, Volt + Universal channels
reserved part no.
reserved part no.
reserved part no.
analogue outputs 1…4
Not available
2 ch. - 0/4… 20mA, Volt
4 ch. - 0/4… 20mA, Volt
USB port
Not available
communication ports
COM1 RS485/232 + COM2 RS485
reserved part no.
connections
Clamp type
69.3
8+32 digital
mp02
To compose the part number, pls. choose one of the option for each variable
12.7
2 universal analogue
COnnections
46.2
6 analogue
MP02
6x 0...10V, 0/1...5V, 0...1V - 0/4...20mA
Resolution: 16 bit
Accuracy: 0.1% of span
Input impedance >100kΩ (V); 300Ω (mA)
Insulation 800 V between power supply and logic
±15 mV, ± 35mV, ±50 mV, ±100 mV, ±300 mV, ±1.25 V,
TC (L, J, T, K, S, R, N), Pt100, Pt1000 and potentiometer (0.1... 10kΩ)
Resolution: 16 bit
Accuracy: 0.1% of span
Input impedance >10 MΩ (V)
Insulation 800 V between power supply and logic
40 Vpp between the channels (differential inputs)
8 + 32 (with expansion units) 24 Vdc (ON: 5...30V, OFF: 0..3V) or 8 + 8/16 max. 120 Vac
Counter input 80 Hz max. frequency
Sink type
Protection: Reverse polarity and overvoltage
Insulation 800 V between power supply and logic
46.2
inputs
COMBUSTION
CONTROL
how to order
features
40.7
•compact PROGRAMMABLE
COntroller (micropac) + on board
I/O and expansion capability
•8 a/i + 8 d/i
•4 a/o + 8 d/o
110
mp02 sigma2
IND U S T R I A L A U T OM AT I O N | PA C S Y S T EM S
106
107
IND U S T R I A L A U T OM AT I O N | PA C S Y S T EM S
INDUSTRIAL
CONTROLLERS
mp-d 1/2/4
Mounting
Front protection degree
Connections
Operating / storage temperature
Operating humidity
8 relay outputs 2A, NO
MP-D1/16-16/M0
16 inputs (24 Vdc)
16 outputs (24 Vdc, 0.5A)
76 x 110 mm, depth 66 mm / 220 g
On OMEGA DIN A rail
IP 20
Terminal block with CLAMP connectors
0… +50°C (32… +122°F) / -20…+85°C (-4… +185°F)
5… 95 RH% without condensation
152 x 110 mm,
depth 66 mm / 350 g
mp-d1 / mp-d2 / mp-d4
To compose the part number, pls. choose one of the option for each variable
expansion units - Sigma2 microPAC
MP-D1/08-08/M0
MP-D1/16-16/M0
24 Vdc (-15... +25%) (50/60 Hz)
4 VA
COnnections
DIN RAIL
MOUNTING
CONTROLLERS
8 outputs (24 Vdc, 0.5A)
MP-D4/08-08/M0
8 inputs (120 Vac)
MP-D2/08-08/M0
MP-D4/08-08/M0
8 digital inputs 24Vdc optoisolated +
8 digital outputs 24V 0.5V optoisolated
16 digital inputs 24Vdc optoisolated +
16 digital outputs 24V 0.5V optoisolated
8 digital inputs 24Vdc +
8 digital outputs 230Vac/2A relay SPST-NO
8 digital inputs 120Vac +
8 digital outputs 230Vac/2A relay SPST-NO
PC
TABLET
HMI
internet
cloud
CELL
PHONES
ROUTER
THERMOSTATS
ANALOGUE
CONTROLLERS
Dimensions / Weight
MP-D1/08-08/M0
MP-D2/08-08/M0
8 inputs (24 Vdc)
MODEM
Remote I/O
INPUTS
REMOTE
SUPERVISOR
OUTPUTS
PAC SYSTEMS
inputs
Digital
outputs
Digital
GENERAL
Power supply
Power consumption
SPECIAL
CONTROLLERS
AND “CUSTOM”
how to order
features
ADVANCED
PROGRAMMER
CONTROLLERS
•expansion units
for micropac MP02
PREPROGRAMMED
SYSTEMS
dimensions
mp-d1 / mp-d2 / mp-d4
20.6
46.2
22
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
PLC AND
OPERATOR
PANELS
69.3
45.2
152
TIMERS
COUNTERS
POWER LIMITERS
76
40.7
46.2
110
12.7
65.8
108
109
IND U S T R I A L A U T OM AT I O N | PA C S Y S T EM S
0
2
5
DIN RAIL
MOUNTING
CONTROLLERS
ROUTER
MODEM
internet
cloud
OUTPUTS
PC
TABLET
HMI
1
CELL
PHONES
0
/ABA
PAC SYSTEMS
0
9
dimensions
available models
65.8
76
40.7
46.2
110
CU-02 2010
Control unit with Ethernet port,
RS232 and 2 additional serial comms. (232+485)
Control unit with Ethernet port,
RS232 and Profibus DP slave
45.2
152
20.6
46.2
22
accessories
The dimensions are expressed in mm
CABLES
APS2 CABLECUCONF
APS2 CABLECUPROG
POWER ADAPTOR 3.2 A
POWER ADAPTOR 5 A
PLUG WITH 11 polE CLAMP TERMINALS
PLUG WITH 14 polE SCREW TERMINALS
ACCESSORIES
COMBUSTION
CONTROL
POWER ADAPTORS
APS2 ALDR75-24
APS2 ALDR12024
PLUGS
APS2 SPINAM11
APS2 SPINAV11
RS232 CABLE 2m, config. CU,
PC-DB9F/CU-RJ45
Ethernet CABLE 2m, programm. CU,
PC-RJ45/CU-RJ45
SPECIAL
CONTROLLERS
AND “CUSTOM”
0
1
INPUTS
THERMOSTATS
ANALOGUE
CONTROLLERS
Remote I/O
cu02
CU-02 5010
Note: SigmaPAC is a programmable distributed controller, modular and open.
It is based on a CANOpen network to which are connected the I/O modules.
I/O modules: See section “Acquisition and data recording”.
CU02
REMOTE
SUPERVISOR
PREPROGRAMMED
SYSTEMS
24 Vdc (-15... +25%) (50/60 Hz)
6.5 VA
152 x 110 mm, depth 66 mm / 430 g circa
On OMEGA DIN A rail
IP 20
0… +55°C (32… +131°F) / -20…+85°C (-4… +185°F)
5… 95 RH% without condensation
Code
- 01
- 02
PLC AND
OPERATOR
PANELS
ARM 32 bit
16 MB of RAM system, 128 kB redundant FLASH memory
IL, ST, FBD, LD, SFC, CFC
IEC61131-3
on board
≥5ms (10ms tipical)
1xEthernet + 1xRS485 (CANOpen) + 1xRS232 + 1xRS232/USB + 1xRS485
Modbus RTU (Master/Slave), Modbus TCP Server, CANOpen Master, Profibus DP, ASCII
cpu module - sigma2
Model 01 - spare parts only
Model 02
serial communication
Not available
ProfiBus
RS232 + RS485
serial communications
RS232
USB
Ethernet
Available
instruction manual
Italian / English
Not available
customization
Standard
Customized
TIMERS
COUNTERS
POWER LIMITERS
functional
Processor
Memory
Programming languages
Standard
Real time clock
Execution cycle Minimum time
Serial ports
Protocols
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
cu02
To compose the part number, pls. choose one of the option for each variable
INDICATORS
1x relay 1A 120Vac/24Vdc resistive load
for Watchdog and Wake Up functions
Digital
COnnections
I/O MODULES
control unit - sigmapac line - CU02
one input 24Vdc NO contact
69.3
input
Digital
outputs
SUPERVISION
how to order
features
12.7
•distributed programmable
controller
•CANOpen + ethernet
•2xrs232 e 1xrs485
•1 profibus dp slave port
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
cu02 sigma2
110
111
Programming languages
Programming
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
IEC 61131-3 programming software
screenshots
DIN RAIL
MOUNTING
CONTROLLERS
Software OpenPCS
APS2 SWOPCS00
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
TIMERS
COUNTERS
POWER LIMITERS
PLC AND
OPERATOR
PANELS
Libraries
Software OpenPCS
IEC 61131-3
Instruction List
Structured Text
Function Block Diagram
Ladder Diagram
Sequential Function Chart
Continous Function Chart Application project developing structured and simplified by the variable declaration method
and keywords auto-recognition.
Integrated online debug and simulation tools.
Projects management “easy to use” trough the dedicated browser.
AT_Generic_Advanced_Lib: includes advanced calculation and process functions such as Averages,
Characterizations/Linearizations, A/D conversions, A/D Selectors, Totalizators, Limiters
AT_Process_Generic_Lib: includes advanced calculation and process functions such as Alarms, Singnal’s conditioning,
Dew point, Relative Humidity, Bacteria load reduction (F0), Compensated flow, Carbon potential calculation
AT_IO_Modules_Basic_Lib: specifically designed to configure and manage the I/O modules
AT_Process_Control_Lib: includes all the advanced PID functions dedicated to the process control
such as single or double action controllers, within different Autotuning and Feed Forward modes
AT_CU02_Cpu_Lib: specifically designed to manage the whole communication
and diagnostic operations of the onboard I/Os and remote modules
AT_Communications_Lib: includes a complete set of function blocks dedicated to the Modbus Master,
Slave and Profibus agents communication activities plus Modems management.
THERMOSTATS
ANALOGUE
CONTROLLERS
functional
Standard
SPECIAL
CONTROLLERS
AND “CUSTOM”
how to order
features
PAC SYSTEMS
•programming Software
compliant to standard IEC 61131-3
•6 programming languages
•wide range of libraries to
simplify the programming
PREPROGRAMMED
SYSTEMS
openpcs
IND U S T R I A L A U T OM AT I O N | PA C S Y S T EM S
112
113
pre-programmed systems
Solutions ready to be used!
Flexible systems able to suit to all plants, through a simple configuration and programming
by means of touch screens.
114
115
INDUSTRIAL
CONTROLLERS
operator panels
CODE
THERMOSTATS
ANALOGUE
CONTROLLERS
P
SPECIAL
CONTROLLERS
AND “CUSTOM”
P
4
6
8
8
operator panels
components
PREPROGRAMMED
SYSTEMS
ClimaPAC
The control system climaPAC is able to perform :
boiler control in power or temperature
the cascade of condensing modules
adjustment of 3 independent heating outlets each with temperature curve
and weekly programmable thermostat with 8 slots for attenuation
adjustment of domestic hot water in the boiler
the management of the recirculation circuit with programmable time bands
the function against legionella
management of solar panels
reading counts calories in the central
the remote management climaPAC allows to monitor online the system, to examine
continuous recording of process data, to work on the operative parameters
( programmable thermostats, curves weather, etc . )
access to facilities and functionality is regulated by password
for each plant the interventions carried out by the various operators can be recorded and it is possible to
upload electronic documents so that it is always available via the Internet
CPS02
Operator panel
Without Operator panel
With Operator panel integrated in the system
Modem
Without Modem
With UMTS Modem for remote management
INPUTS expansion modules
Without modules
With 4 PT1000 inputs modules (for transfer of solar thermal)
With 6 PT1000 inputs modules
With 8 PT1000 inputs modules
outputs expansion modules
Without modules
With 8 0… 10V control outputs modules
Accessories
OPKIT - Kit made of 7” Touch screen operator panel with connection cables
R2IA46P015NPSCO - PT1000 6X40 mm probe in ABS case
R2IB126P15NPS - PT1000 6X120 mm probe with 1.5 m PVC cable
9TUDRC102 - Thermowell for immersion probes 1/4 gas thread, pipe 7.5x60 mm
under-thread 60 mm with PG7 connector
PLC AND
OPERATOR
PANELS
FEATURES
Functions
ADVANCED
PROGRAMMER
CONTROLLERS
To compose the part number, pls. choose one of the option for each variable
pre-programmed solution
electric panel
probes and thermowell
m81
hydraulic diagram
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
System elements
Electric panel code CPS 02
Kit external operator panel
Supervision via Web ClimaVEM
PT1000 probe with thermowell and PT1000 probe for external mounting
DIN RAIL
MOUNTING
CONTROLLERS
HOW TO ORDER
PAC SYSTEMS
•“Turn key” solution for boiler
rooms
•Complete control solution with
high connectivity
TIMERS
COUNTERS
POWER LIMITERS
clima
pac
IND U S T R I A L A U T OM AT I O N | P R E -P R O GR A MME D S Y S T EM S
116
117
m81
features
Functions
BreweryPAC
Solution that allows to control the temperature in the fermenter for beer production.
Enabling is done through the touch screen and allows both control and supervision
of individual fermenters. The modularity of the system is 8.
Temperature control of the fermentors
Temperature real time trend with time base of 1, 3, 6, 12 hours
Daily historical trend
Alarm management
Alarm history recording
Remote Management via Ethernet (also via the Web, via tablet or PC)
PRE-PROGRAMMED SOLUTION
Operator panel OPMT3105/N
Modular solution: 1 to 32 controllers mod. K31 or
1 to 4 M81 controllers (each controlling 8 zones)
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
TIMERS
COUNTERS
POWER LIMITERS
PLC AND
OPERATOR
PANELS
System components
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
components
DIN RAIL
MOUNTING
CONTROLLERS
BP01 XXX-YY
OPMT3105/N pre-programmed with BreweryPAC interface on board
no. 1… 8 Controllers mod. M81 pre-programmed with BreweryPAC applicative
no. 1… 32 Controllers mod. K31
THERMOSTATS
ANALOGUE
CONTROLLERS
To compose the part number, pls. choose one of the option for each variable
screenshots
SPECIAL
CONTROLLERS
AND “CUSTOM”
how to order
PAC SYSTEMS
•pre-programmed system
to manage brewery plants
PREPROGRAMMED
SYSTEMS
brewery
pac
IND U S T R I A L A U T OM AT I O N | P R E -P R O GR A MME D S Y S T EM S
118
119
INDUSTRIAL
CONTROLLERS
components
FEATURES
Functions
Electric panel code CPS 03
Electric power panel code LPS 01
operator panels
electric panel
THERMOSTATS
ANALOGUE
CONTROLLERS
electric panel
dimensions
SPECIAL
CONTROLLERS
AND “CUSTOM”
What is it ?
LightPAC
It is a control system to be installed in electrical cabin with optional functionality to handle
remote commands with a Point to Point connection from a PC.
The control system LightPAC consists of two electric panels :
one for the power (LPS 01) and one for the control (CPS 03).
The system is able to perform the programming of the load distribution of the
lighting three-phase or single phase systems. The control panel is interfaced with the power panels LPS 01
equipped with power controllers TH...E series: these can control single-phase systems
or three-phase power up to 60A.
Power supply voltage reduced lighting
Adjustment of the light depending on times (10 progr. with 6 slots)
Measure of the current supplied
Calculation of power and energy saving
Registration of the average daily savings
Remote Management via Ethernet (also via the Web)
ADVANCED
PROGRAMMER
CONTROLLERS
•Soluzione di telecontrollo per
la ripartizione del carico luci
DIN RAIL
MOUNTING
CONTROLLERS
light pac
IND U S T R I A L A U T OM AT I O N | P R E -P R O GR A MME D S Y S T EM S
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
TIMERS
COUNTERS
POWER LIMITERS
PLC AND
OPERATOR
PANELS
PREPROGRAMMED
SYSTEMS
System components
PAC SYSTEMS
PRE-PROGRAMMED SOLUTION
120
121
plc and operator panels
Solutions for every demand of
space!
PLC and operator panels with bright TFT display widescreen high resolutionre back lighted LED
and up to 256 MB of memory.
For every application where power and control have to be separate from the HMI, we offer
operator panels, both for front panel mounting and with custom dimensions.
122
123
·
OPMT 3105/n
OPMT 3120
OPMT 3150/N
·
·
·
128
128
262 K
·
·
128
64
65 K
128
64
66 K
128
64
67 K
·
·
·
·
·
·
256
256
16.7 M
·
·
·
·
·
·
128
64
68 K
·
·
·
·
·
·
128
64
68 K
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
256
256
16.2 M
·
·
·
·
·
·
·
·
·
256
256
262 K
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
P01
78 x 35
on request
12 Vdc
9 Vdc
P30
·
P32
·
·
·
·
·
·
·
·
·
·
·
THERMOSTATS
ANALOGUE
CONTROLLERS
·
OPMT 8100i
SPECIAL
CONTROLLERS
AND “CUSTOM”
OPMT 3070
PAC SYSTEMS
24 Vac/Vdc
OPMT 8070iH
·
·
·
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
Single display
Double display
Power supply
(from the controller)
TTL Modubus not isolated
CE certification + UL approval
OPMT 6050iV
·
·
features
Dimensions (mm)
OPMT 8050i
·
PREPROGRAMMED
SYSTEMS
Flash MB memory
RAM MB memory
Colours
Slot SD/SDHC card
USB Host
USB Client
Ethernet
Power supply
Audio
Video
COM1 RS232/485 2 4 wires
COM2 RS232
COM3 RS232/485 2 wires
COM1 RS485 2 wires
CAN bus
Programming Software (optional)
CE certification + UL approval
p04
·
PLC AND
OPERATOR
PANELS
Dimensions (inches)
4.3"
7"
10"
10.4”
12.1"
15"
INDICATORS
features
TIMERS
COUNTERS
POWER LIMITERS
plc and operator panels
DIN RAIL
MOUNTING
CONTROLLERS
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
IND U S T R I A L aut o m ati o n | pl c and o p e rat o r pane ls
124
125
UL V04 Autoextinguishing plastic
83 x 159 x 28 mm
200 g
IP65
0... +50°C (32°... +122°F) /-20... +60°C (-4... +140°F)
10...90% RH without condensation
xx
e
u
S
L
C
M
c
E
N
B
r
s
w
DIN RAIL
MOUNTING
CONTROLLERS
157
156
80.4
125
The dimensions are expressed in mm
156
156
79.4
THERMOSTATS
ANALOGUE
CONTROLLERS
p
134
SPECIAL
CONTROLLERS
AND “CUSTOM”
125.5
Code
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
QT programming tool
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
24 Vdc/Vac ±20%
250
p04
model
Touch screen 4.3” operator panel
Touch screen 4.3” operator panel with PLC function on board
applicative on board
Code that defines the applicative
ethernet port
Not available
Ethernet
usb port
Not available
USB
com port
Not available
RS485
AT LIN
CAN
sd card
Not available
SD card memory
clock
Not available
Real Time Clock
connections
Plug-in screw type with connectors included
No connectors
case - colour and shape
Black, rectangular
Black, rounded
White, rectangular
White, rounded
PAC SYSTEMS
ARM9 26 32 Bits 4545 MHz processor
programmable with standard languages IEC61131-3, simulator and application monitor for debugger
4 GB Micro SD
2.0 x 1
10/100 base-T
COM1 RS485 2w
Modbus RTU, ASCII, TPC, CANOpen
Available
P04
To compose the part number, pls. choose one of the option for each variable
PREPROGRAMMED
SYSTEMS
128
128
dimensions
PLC AND
OPERATOR
PANELS
p04
4.3” TFT
480 x 272
280
LED
262 K
4 wire Resistive Type
80
DISPLAY
Display
Resolution (pixel)
Brightness (cd/m²)
Back Light type
Colours
Touch panel
MEMORy
Flash (MB)
RAM (MB)
functional
CPU
PLC
Slot SD card
USB Host
Ethernet
COM port
Fieldbuses
RTC
power supply
Power supply
Power consumption (mA @24V)
MEChanical
Case
Dimensions
Weight
Protection degree
Operating temperature / Storage
Operating humidity
SOFTWARE
Graphic interface
TIMERS
COUNTERS
POWER LIMITERS
how to order
features
80
•plc with Touch screen monitor
•TFT widescreen High resolution
backlighted LED Display
•4.3”
66
p04
IND U S T R I A L aut o m ati o n | pl c and o p e rat o r pane ls
126
127
IND U S T R I A L aut o m ati o n | pl c and o p e rat o r pane ls
350
500
500:1
LED
65 K
16.7 M
4 wire Resistive Type
128
64
128
Available
Not available
10/100 T
Not available
Not available
Available
Not available
COM1 RS232/RS485 2 and 4w,
COM3 RS485 2w
Not available
Not available
Available
128
256
256
1.1 x 1
Not available
SD/SDHC
2.0 x 1
2.0 x 1
10/100 base-T
COM1 RS232/485 2 and 4w,
COM3 RS232/RS485 2w
Available
Available
DIN RAIL
MOUNTING
CONTROLLERS
4.3” TFT, 65K colours, wide screen 16/9, 480x272 p.
4.3”TFT , 65K colours, wide screen 16/9, 480X272 p.
7”TFT, 65K colours, 16/9, 800x480 p. 2xUSB+SD card
7” TFT , 16.7M col., 800x480 p. 2xUSB + SD/SDH card
THERMOSTATS
ANALOGUE
CONTROLLERS
7” TFT
800 x 480
OPMT
8050IE
6050IP
8070IE
3070
SPECIAL
CONTROLLERS
AND “CUSTOM”
3070
24 Vdc ±20%
250
250 g
350
UL V04 Autoextinguishing plastic
300 g
600 g
IP65
0... +50°C / 32°... +122°F
10...90% RH without condensation
Programmable with “Easy Builder 8000” software
400
Aluminium
900 g
IP66
-20... +50°C / -4°... +122°F
Programmable with
“Easy Builder Pro” software
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
Software (optional)
8070iE
4.3” TFT
480 x 272
500
COM port
Audio
CAN bus
RTC
power supply
Power supply
Power consumption (mA @24V)
MEChanical
Case
Weight
Protection degree
Operating temperature
Operating humidity
SOFTWARE
6050ip
PLC AND
OPERATOR
PANELS
Display
Resolution (pixel)
Brightness (cd/m²)
Contrast ratio
Back Light type
Colours
Touch panel
MEMORy
Flash (MB)
RAM (MB)
I/O ports
Slot SD card
USB Host
USB Client
Ethernet
8050ie
TIMERS
COUNTERS
POWER LIMITERS
DISPLAY
OPMT
PAC SYSTEMS
how to order
features
PREPROGRAMMED
SYSTEMS
•Touch screen operator panels
•TFT widescreen High resolution
backlighted LED Display
•4.3” and 7”
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
opmt
128
129
IND U S T R I A L aut o m ati o n | pl c and o p e rat o r pane ls
1024 x 768
500
350
700:1
LED
16.2 M
256
256
Not available
1.1 x 1
Not available
SD/SDHC
2.0 x 1
2.0 x 1
PAC SYSTEMS
128
128
10/100 base-T
COM1 RS232/485 2 and 4w,
COM3 RS232/RS485 2w,
CAN Bus (CANOpen protocol)
Available
NTSC/PAL RCAx2
Available
COM1 RS232/485 2 and 4w,
COM3 RS485 2w
Not available
24 Vdc ±20%
400
800
850
UL V04 Autoextinguishing plastic
1.300 g
1.600 g
2.100 g
IP65
IP66/NEMA4
0... +50°C / 32°... +122°F
10...90% RH without condensation
Programmable with
“Easy Builder 8000”
software
10” TFT , 65K colours, 800x480 p. 2xUSB + SD card
10.4” TFT , 262K colours, 800x600 p. 2xUSB + SD card
12,1” TFT, 16.2M colours, 1024x768 p. 2xUSB
15” TFT, 16.2M colours, 1024x768 p. 2xUSB
SPECIAL
CONTROLLERS
AND “CUSTOM”
4 wire Resistive Type
OPMT
8100I
3105/N
3120
3150/N
900
Aluminium
Programmable with “Easy Builder Pro” software
2.750 g
IP65
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
Software (optional)
262K
3150/N
15” TFT
PREPROGRAMMED
SYSTEMS
Audio
Video
RTC
power supply
Power supply
Power consumption (mA @24V)
MEChanical
Case
Weight
Protection degree
Operating temperature
Operating humidity
SOFTWARE
65 K
3120
12.1” TFT
PLC AND
OPERATOR
PANELS
COM port
3105/n
10.4” TFT
800 x 600
400
400:1
TIMERS
COUNTERS
POWER LIMITERS
Display
Resolution (pixel)
Brightness (cd/m²)
Contrast ratio
Back Light type
Colours
Touch panel
MEMORy
Flash (MB)
RAM (MB)
I/O ports
Slot SD card
USB Host
USB Client
Ethernet
8100iE
10” TFT
800 x 480
300
500:1
INDICATORS
DISPLAY
OPMT
DIN RAIL
MOUNTING
CONTROLLERS
how to order
features
THERMOSTATS
ANALOGUE
CONTROLLERS
•Touch screen operator panels
•TFT widescreen High resolution
backlighted LED Display
•10”, 10.4”, 12.1” and 15”
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
opmt
130
131
IND U S T R I A L aut o m ati o n | pl c and o p e rat o r pane ls
12 Vdc supplied by the controller
Internal buzzer (optional)
TTL Modubus not isolated
ModBus-RTU (JBUS)
38400 baud
9 Vdc supplied by the controller
50 mA
On request / 115 g approx.
78 x 35 mm - depth 64 mm / 120 g approx.
Behind layout
Flush in panel in 71 x 29 mm hole
-IP65, mounted on panel with gasket
Screw terminals
Screw terminal block 2.5 mm²
0... 50°C (32… 122°F) / -20… 70°C (-4… 158°F)
20… 95 RH% without condensation
Directive EMC 2004/108/CE (EN 61326) - Directive LV 2006/95/CE (EN 61010-1)
Code
P30 / P32
Display
Red
Blue
Buzzer (internal)
Available
Not available
Code
K30
1
5
2
4
-
3
3
W
-
4
2
5
1
A
U
p32
U
B
-
P30
K30
1
5
2
4
3
3
4
2
5
1
P32
dimensions
INDICATORS
p30 / p32
6
12.2
28
35
78
SUPERVISION
64
35
78
DIN RAIL
MOUNTING
CONTROLLERS
P01
Display
Red
Amber
Blue
Input
From the connected controller
Output
Out 8 Vdc
Not available
THERMOSTATS
ANALOGUE
CONTROLLERS
500 ms
--
p30
To compose the part number, pls. choose one of the option for each variable
SPECIAL
CONTROLLERS
AND “CUSTOM”
P32
Dual:
Main: 4 red digit, h 7 mm
Secondary: 4 red digit, h 7 mm
PAC SYSTEMS
FUNctional
Sampling rate
Acoustic alarm
Serial communication
Protocol
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Front protection degree
Connections
Operating / storage temperature
Operating humidity
Conformity
P30
Single:
4 red digit, h 12 mm
+ Bargraph 3 LED
PREPROGRAMMED
SYSTEMS
Display
P01
Single:
4 red digit, h 15.5 mm
+ Bargraph 3 LED
TIMERS
COUNTERS
POWER LIMITERS
DISPLAY
COnnections
PLC AND
OPERATOR
PANELS
how to order
features
I/O MODULES
•remote operator panels
•external power supply (by a
separated control unit)
•78 x 35 mm or on request
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
p 01/30/32
ACCESSORIES
COMBUSTION
CONTROL
The dimensions are expressed in mm
132
133
timers - counters power limiters
Multi-scale and multi-function
Microprocessor based timers, counters and power limiters with 4 digits single display,
equipped with double outputs and screw terminal block. Some models are also available
with buffer battery for time counting also in lack of supply.
134
135
4 digit single display
6 digit single display
Input
TT73
TC34
·
·
Counters
TC49
power limiters
TC73
TP34
·
·
·
TP49
·
·
·
·
·
·
·
·
·
·
·
·
·
2
·
·
2
·
·
2
·
·
2
·
·
2
·
·
2
·
·
2
·
·
2
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
2 for free voltage contacts
2 for voltage contacts
Relay or voltage for SSR drive outputs
Relay outputs
Power supply
TT49
2
12 Vac/Vdc
24 Vac/Vdc
100… 240 Vac
·
·
·
·
·
·
·
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
TIMERS
COUNTERS
POWER LIMITERS
PLC AND
OPERATOR
PANELS
Multi-scale, Multi-function
Multi-frequency, Multi-function
40 daily and/or weekly programs
Manual output driving, Daylight saving time function, Random function
CE certification
THERMOSTATS
ANALOGUE
CONTROLLERS
78 x 35
48 x 48
72 x 72
70 x 84
4 DIN Modules
TT34
·
SPECIAL
CONTROLLERS
AND “CUSTOM”
Dimensions (mm)
BWT40
PAC SYSTEMS
Timers
FEATURES
PREPROGRAMMED
SYSTEMS
timers - counters - power limiters
DIN RAIL
MOUNTING
CONTROLLERS
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
industrial A U T OM Ati o n | time rs - c o unt e rs - p o w e r limit e rs
136
137
Up to 2
FUNCTIONAL
Programmable functions
GENERAL
Power supply
Power consumption
Battery
Accuracy
Dimensions / Weight
Mounting
Operating / storage temperature
Operating humidity
Pulses programming: adjustable from 0 to 59 sec
Manual outputs driving
Daylight Saving Time
Random Function
40 daily/weekly programs
LED for status indication of the relay outputs
LED indication of the instrument powered
100... 240 Vac ±10% (48...63 Hz)
4.4 VA approx.
Internal 4 years approx.
(at 20 ° C): ± 2.0
35.8 x 90 mm, depth 73 mm / 110 g approx.
On OMEGA DIN A rail
0... 50°C (32… 122°F) / -20… 70°C (-4… 158°F)
30...95% RH without condensation
bwt40
To compose the part number, pls. choose one of the option for each variable
BWT40
Power supply
100… 240 Vac/Vdc
OUT 1
Relay
OUT 2
Relay
Not available
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
OUT 1: Relay SPDT 16 A at 250 VCA or
OUT 1 and OUT 2: Relay SPDT 8 A at 250 VCA
CONNECTIONS
DIN RAIL
MOUNTING
CONTROLLERS
BWT40
Multi-indication, 6 digit
CODE
BWT40HR
H
R
R
-
7
8
BWT40HRR
9 10 11 12
7
8
9 10 11 12
Uscita 1
Uscita 1
Relè 16A@250Vca, cosϕ = 1
2 relè 8A@250Vca, cosϕ = 1
Alimentazione
100... 240Vca
Alimentazione
100... 240Vca
1
2
3
4
5
6
1
2
Uscita 2
3
4
5
6
DIMENSIONS
bwt40
49
73
34.3
68
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
The dimensions are expressed in mm
TIMERS
COUNTERS
POWER LIMITERS
90
PLC AND
OPERATOR
PANELS
35.8
THERMOSTATS
ANALOGUE
CONTROLLERS
DISPLAY
Single LCD
OUTPUTS
SPECIAL
CONTROLLERS
AND “CUSTOM”
how to order
FEATURES
PAC SYSTEMS
•multifunction timer programmer
•Up to 2 OUTPUTS
•Up to 40 daily and weekly
programs
PREPROGRAMMED
SYSTEMS
BWt40
industrial A U T OM Ati o n | time rs - c o unt e rs - p o w e r limit e rs
138
139
industrial A U T OM Ati o n | time rs - c o unt e rs - p o w e r limit e rs
12 Vac/Vdc, 24 Vac/Vdc, 90… 240 Vac/Vdc ±10% (50/60 Hz)
2 VA approx.
9 mA approx.
4.5 mA approx.
External 9 V - E type
Internal 3.6 V - rechargeable
1 mA max.
48 x 48 mm (1/16DIN) 72 x 72 mm - depth 96 mm /
depth 98 mm / 200 g approx.
270 g approx.
Screw terminal block 2x1 mm²
Flush in panel in 29 x 71 mm hole
Flush in panel in 45 x 45 mm hole Flush in panel in 66.5 x 66.5 mm hole
IP 65, mounted on panel with gasket
IP 54, mounted on panel with gasket
0... 50°C (32… 122°F) / -20… 70°C (-4… 158°F)
30… 95 RH% without condensation
Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1)
33 x 75 mm - depth 64 mm /
175 g approx.
THERMOSTATS
ANALOGUE
CONTROLLERS
F
H
L
SPECIAL
CONTROLLERS
AND “CUSTOM”
V
C
RR
OO
B
-
tt49
DIMENSIONS
tt34
6
78
12.2
64
78
tt73
The dimensions are expressed in mm
9.5
48
INDICATORS
tt49
Note: The external battery (9V - type E) is provided only on request.
The battery is used to keep counting even in the absence of supply.
98
SET
Out1 Out2
-
=
+
I/O MODULES
44.5
48
AT
ST
Out3 Out4
The dimensions are expressed in mm
tt73
9
COMBUSTION
CONTROL
8
72
Out1 Out2
- =
55
72
SET
65.5
AT
ST
+
88
140
PAC SYSTEMS
OUT 1: Delayed, Feedthough, oscillator (start/stop) with asymmetric times start ON,
or start OFF, One cicle asymmetric oscillator (start/stop) with start OFF,
OUT 2: as OUT 1, as instant contact, as OUT 1 but with another independent time,
as OUT 1 but with another relative time
9999 hrs - 99 hrs 59 min - 99 min 59 sec - 99 sec 99 cent. sec
UP or DOWN
According to the used scale : hrs - min - sec - Cent sec
According to the used ext. battery
Approx. 10 hrs with full load battery
tt34
CODE
PREPROGRAMMED
SYSTEMS
OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or 12 Vdc/15 mA to drive SSR
TT34 / TT49 / TT73
Power supply
12 Vac/Vdc
100… 240 Vac/Vdc
24 Vac/Vdc
INPUT
Voltage
Free voltage
OUT 1 + OUT 2
Relay
Vdc for SSR driving
Battery (TT49 and tt73 only)
Internal
External - 9V Type E
PLC AND
OPERATOR
PANELS
2 for free voltage contacts or 2 for voltage contacts (the same of the power supply)
15 msec max.
To compose the part number, pls. choose one of the option for each variable
TIMERS
COUNTERS
POWER LIMITERS
Connections
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
4 red digit, h 12 mm
CONNECTIONS
SUPERVISION
Dimensions / Weight
TT73
4 red digit, h 14 mm
28
Programmable time scales
Counting mode
Display resolution
Counting autonomy without power supply
GENERAL
Power supply
Power consumption
Power consumption with battery
supply
Battery
Power consumption voltage inputs
TT49
35
Programmable functions
TT34
35
DISPLAY
Single
INPUTS
Digital inputs
Delay time inputs
OUTPUTS
Up to 2
FUNCTIONAL
DIN RAIL
MOUNTING
CONTROLLERS
how to order
FEATURES
The dimensions are expressed in mm
ACCESSORIES
•Multiscale and Multifunction
Timers
•Up to 2 OUTPUTS
•with back up battery
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
tt 34/49/73
141
industrial A U T OM Ati o n | time rs - c o unt e rs - p o w e r limit e rs
how to order
12 Vac/Vdc, 24 Vac/Vdc, 90… 240 Vac/Vdc ±10% (50/60 Hz)
3 VA approx.
1 mA max.
33 x 75 mm - depth 64 mm /
48 x 48 mm (1/16DIN) 72 x 72 mm - depth 96 mm /
175 g approx.
depth 98 mm / 200 g approx.
270 g approx.
Screw terminal block 2x1 mm²
Flush in panel in 29 x 71 mm hole
Flush in panel in 45 x 45 mm hole Flush in panel in 66.5 x 66.5 mm hole
IP 65, mounted on panel with gasket
IP 54, mounted on panel with gasket
0... 50°C (32… 122°F)/-20… 70°C (-4… 158°F)
30… 95 RH% without condensation
Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1)
tc34
CODE
THERMOSTATS
ANALOGUE
CONTROLLERS
F
H
L
V
C
SPECIAL
CONTROLLERS
AND “CUSTOM”
Restart - Restart/Lap - Count
2 - 10 - 40 - 125 - 1000 Hz. Programmable
UP or DOWN
9999
Programmable Back-up function in case of power supply failure
TC34 / TC49 / TC73
Power supply
12 Vac/Vdc
100… 240 Vac/Vdc
24 Vac/Vdc
INPUT
Voltage
Free voltage
OUT 1 + OUT 2
Relay
Vdc for SSR driving
RR
OO
DIMENSIONS
tc49
tc34
6
78
12.2
64
78
The dimensions are expressed in mm
tc49
9.5
98
44.5
48
AT
ST
SET
=
+
Out3 Out4
I/O MODULES
-
tc73
INDICATORS
48
Out1 Out2
PAC SYSTEMS
OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or 12 Vdc/15 mA to drive SSR
To compose the part number, pls. choose one of the option for each variable
PREPROGRAMMED
SYSTEMS
2 for free voltage contacts or 2 for voltage contacts (the same of the power supply)
15 msec max.
CONNECTIONS
PLC AND
OPERATOR
PANELS
4 red digit, h 12 mm
TC73
4 red digit, h 14 mm
35
Connections
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
TC49
TIMERS
COUNTERS
POWER LIMITERS
Dimensions / Weight
TC34
28
DISPLAY
Single
INPUTS
Digital inputs
Delay time inputs
OUTPUTS
Up to 2
FUNCTIONAL
Programmable functions
Frequenza di conteggio
Counting mode
Display resolution
Back up memory
GENERAL
Power supply
Power consumption
Power consumption voltage inputs
35
FEATURES
DIN RAIL
MOUNTING
CONTROLLERS
•multifunction and
multifrequency Counters
•Up to 2 OUTPUTS
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
tc 34/49/73
The dimensions are expressed in mm
Out1 Out2
- =
55
72
SET
65.5
AT
ST
+
88
The dimensions are expressed in mm
142
COMBUSTION
CONTROL
9
ACCESSORIES
8
72
SUPERVISION
tc73
143
12 Vac/Vdc, 24 Vac/Vdc, 90… 240 Vac/Vdc ±10% / 50/60 Hz
2 VA approx.
1 mA max.
Asymmetric oscillator timer (start/stop) with power limiter function
OUT 1: oscillator (start/stop) with asymmetric times start ON, or start OFF
OUT 2: as OUT 1, as OUT 1 but in opposite way,
as OUT 1 but in opposite way with power limiter function
From 1 to 900 sec
33 x 75 mm - depth 64 mm / 175 g approx.
48 x 48 mm (1/16DIN) - depth 98 mm/ 200 g approx.
Screw terminal block 2x1 mm²
Flush in panel in 29 x 71 mm hole
Flush in panel in 45 x 45 mm hole
IP 65, mounted on panel with gasket
IP 54, mounted on panel with gasket
0... 50°C (32… 122°F)/-20… 70°C (-4… 158°F)
30… 95 RH% without condensation
Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1)
tp34
CODE
F
H
L
V
C
R
O
R
O
DIMENSIONS
TP34
6
78
12.2
28
64
35
78
The dimensions are expressed in mm
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or 12 Vdc/15 mA to drive SSR
TP34 / TP49
Power supply
12 VacV/DC
100… 240 Vac/Vdc
24 Vac/Vdc
INPUT
Voltage
Free voltage
OUT 1
Relay
VdcxSSR
OUT 2
Relay
Vdc for SSR driving
THERMOSTATS
ANALOGUE
CONTROLLERS
2 for free voltage contacts or 2 for voltage contacts (the same of the power supply)
15 msec max.
To compose the part number, pls. choose one of the option for each variable
SPECIAL
CONTROLLERS
AND “CUSTOM”
4 red digit, h 12 mm
CONNECTIONS
35
Outputs cycle time
Dimensions / Weight
Connections
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
TP49
tp49
PAC SYSTEMS
Programmable functions
TP34
PREPROGRAMMED
SYSTEMS
DISPLAY
Single
INPUTS
Digital inputs
Delay time inputs
OUTPUTS
Up to 2
GENERAL
Power supply
Power consumption
Power consumption voltage inputs
FUNCTIONAL
Application
PLC AND
OPERATOR
PANELS
how to order
FEATURES
DIN RAIL
MOUNTING
CONTROLLERS
•Limitatori di potenza
•Up to 2 OUTPUTS
TIMERS
COUNTERS
POWER LIMITERS
tp 34/49
industrial A U T OM Ati o n | time rs - c o unt e rs - p o w e r limit e rs
SET
Out1 Out2
-
=
+
44.5
48
AT
ST
Out3 Out4
ACCESSORIES
COMBUSTION
CONTROL
The dimensions are expressed in mm
I/O MODULES
98
SUPERVISION
9.5
48
INDICATORS
TP49
144
145
indicators
Much more than simple indicators!
Digital indicators with one or more universal inputs and potentiometer or with configurable
input. Also available with a dedicated input version strain gauge for melt pressure transducer
and load cell.
146
147
indicators
Auxiliary input
Relay or voltage for SSR drive outputs
Analogue current or voltage outputs
Measuring retransmission
Power supply
J1
J3
J5
·
·
·
·
·
·
·
·
·
·
3
·
3
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
2
2
·
2
4
3
·
·
·
2
3
3
2
1
·
4
1
4
1
·
4
1
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
THERMOSTATS
ANALOGUE
CONTROLLERS
·
SPECIAL
CONTROLLERS
AND “CUSTOM”
·
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
RS485 ModBus
Mathematical Functions
MIN, MAX, HOLD PV, HOLD PICCO, MEDIA functions
CE certification + UL approval
C1
·
4
1
12 Vac/Vdc
20… 30 Vac/Vdc
24 Vac/Vdc
100… 240 Vac
K85V
PAC SYSTEMS
Manin input
K48V
·
·
·
universal input
J-K-S-R-T + IR + PTC-NTC
J-K-S-R-T + IR + Pt100
0/4… 20 mA o
0/1… 5 V o
0… 10V
Δ T PT100
Digital
Strain gauge (5V/10V)
0/4… 20 mA or
0/1… 5 V or
0… 10V
K38V
·
PREPROGRAMMED
SYSTEMS
4 digit single display
5 digit single display
K31V
·
PLC AND
OPERATOR
PANELS
Dimensions (mm)
TLI40
78 x 35
24 x 48
48 x 48
70 x 84
4 DIN Modules
96 x 48
TIMERS
COUNTERS
POWER LIMITERS
FEATURES
DIN RAIL
MOUNTING
CONTROLLERS
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
IND U S T R I A L aut o m ati o n | indi c at o rs
148
149
Auxiliary power supply
12 Vdc/20 mA max
2.5 Vdc/2.5 mA for Linear Potentiometers
FUNCTIONAL
Sampling rate
Resolution
Accuracy
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Connections
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
Selectable from 8 to 64 samples per second for analogue signals or potentiometer inputs
8 samples/sec = 32000 points
16 samples/sec = 16000 points
32 samples/sec = 8000 points
64 samples/sec = 4000 points
±0,15% fs
RS485 with ModBus-RTU (JBUS) protocol
1200… 38400 baud, programmable
24 Vac/Vdc, 100… 240 Vac ±10% / 50/60 Hz
8 VA approx.
48 x 48 mm - depth 98 mm / 190 g approx.
Screw terminal block 2 x 1 mm²
Flush in panel in 45 x 45 mm hole
IP 54 , mounted on panel with gasket
0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F)
30… 95 RH% without condensation
Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1)
CONNECTIONS
R
O
C
V
R
O
R
O
-
tc J
tc K
tc S
tc B
tc E
tc L
tc N
tc R
tc T
tc C
R
O
-
IR sensors (ZIS)
Pt100 (IEC)
S
I
-
PTC (KTY81-121)
B
A
0... 20 mA
-1999 ... 9999
4... 20 mA
-1999 ... 9999
0... 50 mV
-1999 ... 9999
0... 60 mV
-1999 ... 9999
12... 60 mV
-1999 ... 9999
0... 5 V
-1999 ... 9999
1... 5 V
-1999 ... 9999
0... 10 V
-1999 ... 9999
2... 10 V
-1999 ... 9999
Potentiometers (> 1 KΩ)
-1999 ... 9999
-P
--
NTC (103-AT2)
-160.0 ... 999.9 °C
-199.9 ... 999.9 °F
-199.9 ... 999.9 °C
-199.9 ... 999.9 °F
-50.0 ... 999.9 °C
-58.0 ... 999.9 °F
72.0 ... 999.9 °C
162.0 ... 999.9 °F
-150.0 ... 999.9 °C
-199.9 ... 999.9 °F
-150.0 ... 900.0 °C
-199.9 ... 999.9 °F
-199.9 ... 999.9 °C
-199.9 ... 999.9 °F
-50.0 ... 999.9 °C
-58.0 ... 999.9 °F
-199.9 ... 400.0 °C
-199.9 ... 752.0 °F
0.0 ... 999.9 °C
32.0 ... 999.9 °F
-46.0 ... 785.0 °C
-50.8 ... 999.9 °F
-99.9 ... 850.0 °C
-99.9 ... 999.9 °F
-55.0 ... 150.0 °C
-67.0 ...302.0 °F
-50.0 ... 110.0 °C
-58.0 ... 230.0 °F
-199.9 ... 999.9
-19.99 ... 99.99
-199.9 ... 999.9
-19.99 ... 99.99
-1.999 … 9.999
-199.9 ... 999.9
-19.99 ... 99.99
-1.999 … 9.999
-199.9 ... 999.9
-19.99 ... 99.99
-1.999 … 9.999
-199.9 ... 999.9
-19.99 ... 99.99
-1.999 … 9.999
-199.9 ... 999.9
-19.99 ... 99.99
-1.999 … 9.999
-199.9 ... 999.9
-19.99 ... 99.99
-1.999 … 9.999
-199.9 ... 999.9
-19.99 ... 99.99
-1.999 … 9.999
-199.9 ... 999.9
-19.99 ... 99.99
-1.999 … 9.999
-199.9 ... 999.9
-19.99 ... 99.99
-1.999 … 9.999
DIN RAIL
MOUNTING
CONTROLLERS
with “dP”= 1, 2, 3
ACCESSORIES
tli40
L
H
without “dP”
(decimal point)
-160 ... 1000 °C
- 256 ... 1832 °F
-270 ... 1370 °C
- 454 ... 2498 °F
-50 ... 1760 °C
-58 ... 3200 °F
72 ... 1820 °C
162 ... 3308 °F
-150 ... 750 °C
-252 ... 1382 °F
-150 ... 900 °C
-252 ... 1652 °F
-270 ... 1300 °C
-454 ... 2372 °F
-50 ... 1760 °C
-58 ... 3200 °F
-270 ... 400 °C
-454 ... 752 °F
0 ... 2320 °C
32 ... 4208 °F
-46 ... 785 °C
-50 ... 1445 °F
-200 ... 850 °C
-328 ... 1562 °F
-55 ... 150 °C
-67 ... 302 °F
-50 ... 110 °C
-58 ... 230 °F
THERMOSTATS
ANALOGUE
CONTROLLERS
INPUT
CODE
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
OUT 1: 0/4…20mA or 0/2…10V
TLI40
Power supply
20… 30 Vac/Vdc
90… 240 Vac
OUT 1
Relay
20 mA/14 Vdc for SSR driving
0/4… 20mA
0/2… 10V
Not available
OUT 2
Relay
Vdc for SSR driving
Not available
OUT 3
Relay
Vdc for SSR driving
Not available
OUT 4
Relay
Vdc for SSR driving
Not available
Serial communication AND DIGITAL INPUT
RS485
RS485 + Digital input
Not available
sensor Power supply
2.5 Vdc
12 Vdc for analogue input
INPUT FROM potenTIOMETER
Available
Not available
SPECIAL
CONTROLLERS
AND “CUSTOM”
Current or voltage
(as aternative to OUT 1)
TEMPERATURE ranges
PAC SYSTEMS
OUT 1, OUT 2, OUT 3 and OUT 4: Relay SPST-NO (5A-AC1, 2A-AC3/250 Vac)
or 7mA/14 Vdc to drive SSR
To compose the part number, pls. choose one of the option for each variable
PREPROGRAMMED
SYSTEMS
Up to 4
TEMPERATURE RANGEs
PLC AND
OPERATOR
PANELS
Accuracy
OUTPUTS
Thermocouples J, K, S, B, C, E, L, N, R, T and Infrared sensors J or K +
Thermoresistances Pt 100 3 wires +
Thermistors PTC KTY 81-121 (990 Ω a 25°C) e Thermistors NTC 103AT-2 (10 kΩ a 25°C) +
Linear signals 0… 50mV, 0… 60mV, 12… 60mV, 0/4... 20mA, 0/1… 5V, 0/2…10V +
Linear Potentiometers
(see next page for temperature ranges)
±0.15% fs
HOW TO ORDER
TIMERS
COUNTERS
POWER LIMITERS
Universal
TLI40
4 red digit, h 12 mm
INDICATORS
DISPLAY
Single
INPUTS
I/O MODULES
FEATURES
SUPERVISION
•universal and potentiometer
input
•Up to 4 OUTPUTS
•rs485
COMBUSTION
CONTROL
tli40
IND U S T R I A L aut o m ati o n | indi c at o rs
150
151
Auxiliary power supply
FUNCTIONAL
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Connections
Set Point
RS485 with ModBus-RTU (JBUS) protocol
1200… 38400 baud, programmable
-TTL ModBus
--
12 Vac/Vdc, 24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz)
6 VA approx.
78 x 35 mm - depth 64 mm
78 x 35 mm - depth 64 mm / 180 g approx.
or 78.5 mm with plug-in terminals / 180 g approx.
Plug-in terminals or
Screw terminal block 2 x 1 mm²
Screw terminal block 2 x 1 mm²
Flush in panel in 71 x 29 mm hole
IP 65, mounted on panel with gasket
0… 50°C (32… 122°F)/-30… 70°C (-22… 158°F)
20… 85 RH% without condensation
Direttive EMC 2004/108/CE (EN 61326-1), Direttive BT 2006/95/CE (EN 61010-1)
K38V
pOWER SUPPLY
12 Vac/Vdc
24 Vac/Vdc
100… 240 Vac/Vdc
input
TC,PT100,mV
TC,PTC,NTC,mV
0/4… 20mA
0… 1V, 0/1… 5V, 0/2… 10V
OUT 1
Relay SPDT 8A-AC1
Vdc for SSR driving
OUT 2
Relay SPDT 8A-AC1
Vdc for SSR driving
Not available
Code
DIN RAIL
MOUNTING
CONTROLLERS
k38v
THERMOSTATS
ANALOGUE
CONTROLLERS
SPECIAL
CONTROLLERS
AND “CUSTOM”
R
O
R
O
R
O
R
O
S
-
DIMENSIONS
k31v / k38v
F
L
H
C
E
I
V
R
O
R
O
-
78
6
12.2
78
64
The dimensions are expressed in mm
ACCESSORIES
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac)
OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac)
or 12V ±20% 20 mA max. to drive SSR
or 12V ±20% 20 mA max. to drive SSR
OUT 3 and OUT 4: Relay SPST-NO (5A-AC1, 3A-AC3/250 Vac)
or 12V ±20% 20 mA max. to drive SSR
12 Vdc/20 mA max.
C
E
I
V
PAC SYSTEMS
Up to 4 (K31V)
Up to 2 (K38V)
F
L
H
PREPROGRAMMED
SYSTEMS
Digital inputs
OUTPUTS
Code
PLC AND
OPERATOR
PANELS
4 different configurations
Thermocouples J (0... 1000°C/32... 1832°F), K (0… 1370°C/32... 2498°F),
S,R (0… 1760°C/32... 3200°F), T (0... 400°C/32… 752°F) e
Infrared sensors J or K +
Thermoresistances Pt 100 3 wires (-200.. 850°C/-328... 1562°F)
Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F),
S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K +
Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F)
and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F)
Linear signals 0/4… 20mA
Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V
2 for free voltage contacts
--
k31v
K31V
pOWER SUPPLY
12 Vac/Vdc
24 Vac/Vdc
100… 240 Vac/Vdc
input
TC,PT100,mV
TC,PTC,NTC,mV
0/4… 20mA
0… 1V, 0/1… 5V, 0/2… 10V
OUT 1
Relay SPDT 8A-AC1
Vdc for SSR driving
OUT 2
Relay SPDT 8A-AC1
Vdc for SSR driving
Not available
OUT 3
Relay SPST-NO 5A-AC1
Vdc for SSR driving
Not available
OUT 4
Relay SPST-NO 5A-AC1
Vdc for SSR driving
Not available
serial communication
RS485
TTL ModBus
TIMERS
COUNTERS
POWER LIMITERS
INPUTS
To compose the part number, pls. choose one of the option for each variable
INDICATORS
4 red digit, h 12 mm + 3 LEDs Bargraph
CONNECTIONS
I/O MODULES
Single
K38V
SUPERVISION
K31V
28
DISPLAY
COMBUSTION
CONTROL
HOW TO ORDER
FEATURES
35
•programmable Indicators
•Up to 4 OUTPUTS for alarms
management
•Serial communication RS485
or ttl ModBus
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
31v/38v
35
k
IND U S T R I A L aut o m ati o n | indi c at o rs
152
153
IND U S T R I A L aut o m ati o n | indi c at o rs
Up to 3
Auxiliary supply
FUNctional
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions
Weight
Connections
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT1 and OUT2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac)
OUT1 and OUT2: Relay SPST-NO (8A-AC1, 3A-AC3/250 Vac)
or 12V ± 20% 20 mA max. for SSR driving
or 12V ± 20% 20 mA max. for SSR driving
OUT3: Relay SPST-NO (5A-AC1, 3A-AC3/250 Vac)
OUT3: Relay SPST-NO (5A-AC1, 3A-AC3/250 Vac)
or 12V ± 20% 20 mA max. for SSR driving
or 12V ± 20% 20 mA max. for SSR driving
12 Vdc/20 mA max.
-TTL ModBus
--
Set point
RS485 with Modbus RTU protocol
1200… 38400 baud, programmable
24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz)
6 VA approx.
48 x 48 mm (1/16 DIN) - depth 98 mm
4 DIN rail modules, 70 x 84 mm - depth 60 mm
180 g approx.
230 g approx.
Screw terminal block 2.5 mm²
Flush in panel in 45 x 45 mm hole
On OMEGA DIN A rail
IP65, mounted in panel with gasket
IP 40, for internal use
0… 50°C (32… 122°F)/-30… 70°C (-22… 158°F)
30… 95 RH% without condensation
Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1)
C
E
I
V
R
O
R
O
D
R
O
-
k48v
9.5
48
98
44.5
48
AT
ST
SET
-
=
+
THERMOSTATS
ANALOGUE
CONTROLLERS
F
L
H
DIMENSIONS
Out1 Out2
k48v
code
DIN RAIL
MOUNTING
CONTROLLERS
K48V / K85V
pOWER SUPPLY
12 Vac/Vdc
24 Vac/Vdc
100… 240 Vac/Vdc
input
TC,PT100,mV
TC,PTC,NTC,mV
0/4… 20mA
0… 1V, 0/1… 5V, 0/2… 10V
OUT 1
Relay SPDT 8A-AC1
Vdc for SSR driving
OUT 2
Relay SPDT 8A-AC1
Vdc for SSR driving
Not available
OUT 3
2 digital inputs (K48V only)
Relay
Vdc for SSR driving
Not available
SPECIAL
CONTROLLERS
AND “CUSTOM”
OUTPUTS
To compose the part number, pls. choose one of the option for each variable
k85v
PAC SYSTEMS
Thermocouples (0... 1000°C/32... 1832°F), K (0… 1370°C/32... 2498°F), S,R (0… 1760°C/32... 3200°F),
T (0... 400°C/32… 752°F) and Infrared sensors J or K type +
Thermoresistances Pt 100 3 wires (-200.. 850°C/-328... 1562°F)
Thermocouples J (0... 1000°C/32... 1832°F), K (0… 1370°C/32... 2498°F), S,R (0… 1760°C/32... 3200°F),
T (0... 400°C/32… 752°F) and Infrared sensors J or K type +
Thermistors PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C/-67... 302°F)
and Thermistors NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C/-58... 230°F)
Linear signals 0/4… 20mA
Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V
2 digital inputs for free voltage contacts,
2 digital inputs for free voltage contacts
as alternative to Out 3
CONNECTIONS
PLC AND
OPERATOR
PANELS
Digital inputs
K85V
4 red digit, h 12 mm + 3 LEDs bargraph
TIMERS
COUNTERS
POWER LIMITERS
4 different configurations
K48V
4 red digit, h 7mm
INDICATORS
DISPLAY
Single
INPUTS
PREPROGRAMMED
SYSTEMS
HOW TO ORDER
features
Out3 Out4
The dimensions are expressed in mm
I/O MODULES
•indicators
•up to 3 outputs for alarm
indication
•RS485 or ttl serial communication
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
K 48V/85V
27
6 7
21
12
8 9 10 11 12
-
=
+
60
84
Prg
Out1 Out2
45
Tun
Out3
13 14 15 16 17 18 19 20 21 22 23 24
The dimensions are expressed in mm
154
COMBUSTION
CONTROL
4 5
ACCESSORIES
70
1 2 3
SUPERVISION
k85v
155
IND U S T R I A L aut o m ati o n | indi c at o rs
INDUSTRIAL
CONTROLLERS
J1 / j3
Special functions
Update measurement time
Sampling rate
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
Quick Setup using numerical code,
“ISA A” Alarm acknowledge sequence,
Displaying IN1, IN2, CIN (conditioned input),
Displaying max. and min. values,
Display locked / timed,
Peaks and valleys,
Dedicated key for alarms recognition,
Sensor break,
Alarms acknowledgement (latching),
Inhibition at power-on,
OR function
Quick Setup using numerical code,
“ISA A” Alarm acknowledge sequence,
Displaying max. and min. values,
Display locked / timed,
Peaks and valleys,
Dedicated key for alarms recognition,
Sensor break,
Alarms acknowledgement (latching),
Inhibition at power-on,
OR function
0.7 sec
1.5 sec
--
Measurement
RS485 with Modbus RTU protocol
1200, 2400, 4800, 9600 baud
100...240Vac (-15...+10%) or 24Vac (-25...+12%) or 24Vdc (-15...+25%) (50/60 Hz)
5 VA approx.
96 x 48 mm (1/8 DIN), depth 110 mm / 250 g approx.
Flush in panel in 92 x 45 mm hole
Screw terminal block M3 for cables with section 1 mm² (18AWG)
IP65
0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F)
5… 95% RH without condensation
EN61010-1 (IEC1010-1)
DIN RAIL
MOUNTING
CONTROLLERS
CODE
0
1
7
9
Thermocouple
0
5
mV
Pt100
External
shunt 2.5Ω
mA
0
1
2
5
j3
0
V
0
9
0
2
Thermocouple
NA
Pt100
mV
NPN
0
3
mA
Rj
mA
V
mA
TTL
SPECIAL
CONTROLLERS
AND “CUSTOM”
THERMOSTATS
ANALOGUE
CONTROLLERS
3
5
PAC SYSTEMS
OUT 1: Relay SPDT 2A/250Vac (4A/120Vac) for resistive loads
OUT 2 and OUT 3: Relay NO 2A/250Vac (4A/120Vac)
for resistive loads
OUT 1: Relay SPDT 2A/250Vac (4A/120Vac) for resistive loads
OUT 4: Logic not isolated 0/5 Vdc ±10% 30mA max.
OUT 2: Relay NO 2A/250Vac (4A/120Vac) for resistive loads
or Relay NO, 2A/250Vac (4A/120Vac) for resistive loads
OUT 5: 0/4...20 mA for inputs retransmission
24 Vdc (±20%)/30 mA max. for external transmitter
2, programmable as alarm
4, programmable as alarm
J1/J3
Power supply
100… 240 Vac
24 Vac/Vdc
OUT 1, out 2, out 3 and out 4
Not available
Relay-Relay-Relay-SSR (J3 only)
Relay-Relay
Relé-relé-relé-relé (J3 only)
Serial communication
Not available
RS485
SPECIAL FUNCTIONS
Not available
OUT 5 retransmission (J3 only)
Input IN2 (J3 only)
OUT 5 retransmission + IN2 (Solo J3)
SPECIAL FUNCTIONS
Not available
INSTRUCTION MANUAL
Italian/English
Not available
FRONT FRAME COLOUR
Dark grey (std)
Dark grey shunt 0.1%
SPECIAL EXECUTION
Not available
Conformal coating
PREPROGRAMMED
SYSTEMS
Auxiliary power supply
Outputs configuaration
FUNCTIONAL
Thermocouples: L/J (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F), K (0…+1200°C / 32…+2192°F),
S/R (0... +1600°C / 32...2912°F) B (0... +1800°C / 32... 3272°F), N (0... +1200°C / 32... 2192°F),
E (0... +600°C / 32... +1112°F), Ni-NiMo (0... +1100°C / 32... +2012°F), W3/W5 (0... +2000°C / 32... 3632°F)
Thermoresistances: PT100 (-200... +600°C / -328... +1112°F)
Linear signals: 0/10... 50 mV; 0/4…20 mA (shunt)
Infrared sensors or special ranges (custom)
-0/4...20 mA o 0/1...5 V, 0...10 V
3, logic type not isolated
0.25% ±1 digit (thermoelements) or 0.1% ±1 digit (for mA and mV)
j1
To compose the part number, pls. choose one of the option for each variable
PLC AND
OPERATOR
PANELS
Up to 2 (J1)
Up to 5 (J3)
5 digit programmable as red or green, h 15.5 mm
CONNECTIONS
External
shunt 2.5Ω
TIMERS
COUNTERS
POWER LIMITERS
Auxiliary input (IN2)
Digital inputs
Accuracy
OUTPUTS
J3
DIMENSIONS
j1 / j3
INDICATORS
Main input (IN1)
J1
110
96
I/O MODULES
DISPLAY
Single
INPUTS
48
10 max.
SUPERVISION
HOW TO ORDER
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•J1: 5 digit Indicator
with 2 alarms
•J3: 5 digit Indicator
with 2 INPUTS and 4 alarms
ACCESSORIES
COMBUSTION
CONTROL
The dimensions are expressed in mm
156
157
Special functions
INDUSTRIAL
CONTROLLERS
Quick Setup using numerical code,
“ISA A” Alarm acknowledge sequence,
Displaying IN1, IN2, CIN (conditioned input),
Displaying max. and min. values,
Display locked / timed,
Peaks and valleys,
Dedicated key for alarms recognition,
Sensor break,
Alarms acknowledgement (latching),
Inhibition at power-on, OR function
20 ms
0.5 sec
Measurement
RS485 with Modbus RTU protocol
1200, 2400, 4800, 9600, 19200, 36400, 56800 baud
100...240Vac (-15...+10%) or 24Vac (-25...+12%) or 24Vdc (-15...+25%) (50/60 Hz)
5 VA approx.
96 x 48 mm (1/8 DIN), depth 110 mm / 250g approx.
Flush in panel in 92 x 45 mm hole
Screw terminal block M3 for cables with section 1 mm² (18AWG)
IP65
0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F)
5… 95% RH without condensation
EN61010-1 (IEC1010-1)
7
9
PTC
1
Commands
2
Strain gauge transducer
EXC
350
0
5
350
C
4
C
5
IL1
6
IL2
7
IL3
9
27
350
350
11
12
5/10 Vdc
IN 1
mV
20
OP5
OP2
32
OP3
23
24
OP4
IN 2
31
33
34
35
36
CAL
24Vdc
T ransmitter
IN2
4…20mA
mA
Rcal
DIMENSIONS
j5
8
9
0
3
29
30
19
0
1
2
5
0
Alarm
28
OP1
10
SIG
Power
supply
switch
25
26
3
8
~
DIN RAIL
MOUNTING
CONTROLLERS
RS485
3
5
V
Recorder
Supervision
THERMOSTATS
ANALOGUE
CONTROLLERS
CODE
SPECIAL
CONTROLLERS
AND “CUSTOM”
J5
Power supply
100… 240 Vac
24 Vac/Vdc
OUT 1, 2, 3 e 4
Relay-Relay
Relay-Relay-Relay-Relay
Serial communication
Not available
RS485
SPECIAL FUNCTIONS
Not available
OUT 5 retransmission
Input IN2
OUT 5 retransmission+ IN2
SPECIAL FUNCTIONS
Not available
INSTRUCTION MANUAL
English
Not available
SPECIAL EXECUTION
Not available
Conformal coating
110
96
48
10 max.
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
Update measurement time
Sampling rate
Signal retransmission
Serial communication
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT 1: Relay SPDT, 2A/250Vac (4A/120Vac) for resistive loads
OUT 2: Relay NO, 2A/250Vac (4A/120Vac) for resistive loads
OUT 3: Relay NO, 2A/250Vac (4A/120Vac) for resistive loads
OUT 4: Relay NO, 2A/250Vac (4A/120Vac) for resistive loads
OUT 5: 0/4...20 mA for inputs retransmission
24 Vdc (±20%)/30 mA max. for external transmitter
4, programmable as alarm
J5
To compose the part number, pls. choose one of the option for each variable
PAC SYSTEMS
Auxiliary power supply
Outputs configuaration
FUNCTIONAL
0...20/50/100 mV, 0...1/5/10 V, 0/4...20 mA, strain gauge: from 350 Ω, with bridge excitation 5 V or 10 V
0/4...20 mA or 0/1...5 V, 0...10 V
3, logic type not isolated
0.1% ±1 digit (for mA and mV)
CONNECTIONS
PREPROGRAMMED
SYSTEMS
Up to 5
J5
5 digit programmable as red or green, h 15.5 mm
PLC AND
OPERATOR
PANELS
DISPLAY
Single
INPUTS
Main input (IN1)
Auxiliary input (IN2)
Digital inputs
Accuracy
OUTPUTS
TIMERS
COUNTERS
POWER LIMITERS
HOW TO ORDER
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•Indicator-transmitter
•strain gauge INPUT
for melt pressure
and load cells
INDICATORS
j5
IND U S T R I A L aut o m ati o n | indi c at o rs
158
159
acquisition and
data recording
Nothing is so
easy
160
161
i/o modules
Data acquisition modules
in Modbus RTU and CANOpen
Many typologies of digital and analogue inputs and outputs.
162
163
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
a c q uisi z i o ne e r e gistra z i o ne dati | m o duli di i / o
features
Dimensions (mm)
Single module (76 x 110 mm)
Dual module (152 x 110 mm)
Input channels
Output channels
Inputs
Outputs
24 Vdc
120 Vac
24 Vdc
250 Vac
Relay
Outputs 2A
Outputs 6A
Power supply 24 Vdc
CANOpen protocol
Modbus RTU protocol
CE certification + UL approval (listed)
Inputs
16
16
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
DM
32LV
08TS
·
·
32
·
32TS
16TS
·
16TP
·
·
8
8
·
·
16
16
·
16
·
16
·
·
·
·
·
·
8
·
16TS
·
32TR
·
THERMOSTATS
ANALOGUE
CONTROLLERS
SPECIAL
CONTROLLERS
AND “CUSTOM”
·
PAC SYSTEMS
·
·
·
·
DO
32TS
04RL
·
04TX
·
·
32
32
·
08RL
·
4
4
8
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
TDA
4 Din modules (70 x 85 mm)
PTC, NTC or Pt1000
4…20 mA
0… 10 V
Digitals
04
·
4
·
·
·
·
·
08
·
8
·
·
·
·
ACCESSORIES
Power supply 24, 110, 230 Vac
CE certification
DI
16HV
·
·
8
·
features
Dimensions (mm)
Input channels
16LV
·
·
8
PREPROGRAMMED
SYSTEMS
·
·
08dp
·
PLC AND
OPERATOR
PANELS
Resolution 16 bit
Accuracy 0.1%
Power supply 24 Vdc
Fast aquisition
CANOpen protocol
Modbus RTU protocol
CE certification + UL approval (listed)
·
·
08HL
·
TIMERS
COUNTERS
POWER LIMITERS
·
·
·
·
·
·
·
·
·
·
·
·
08DP
·
8
INDICATORS
Thermocouples J,K,N,S,R,T
RTD PT100 and PT1000
Current (mA)
Voltage (mV)
Voltage (V)
Potentiometer
Dual polarity
AO
08HL
·
8
SUPERVISION
Type of inputs
Single module (76 x 110 mm)
ai
08TC
·
8
COMBUSTION
CONTROL
Dimensions (mm)
Input channels
Output channels
AI
04RT
·
4
02UI
·
2
I/O MODULES
features
DIN RAIL
MOUNTING
CONTROLLERS
i/o modules
164
165
a c q uisi z i o ne e r e gistra z i o ne dati | m o duli di i / o
Outputs OUT1-OUT2
OUT1 and OUT2: Relay NO,
2A res./250Vac
(4A res./120Vac) / SSR,
1A res./250Vac
Outputs OUT3-OUT4
--
Output OUT5
Outputs functions
Auxiliary supply
Outputs configuration
Alarm functions
FUNctional
Setpoint
Special functions (optionals)
Front indication LEDs
Unit of measurement
Signal retransmission
Serial communication
Baud rate
Parameters access
GENERAL
Power supply
Power consumption
Dimensions
Weight
Connections
Mounting
Protection degree
Operating / storage temperature
Operating humidity
Conformity
OUT1 and OUT2: Relay NO, 2A res./250Vac
(4A res./120Vac)/SSR, 1A res./250Vac,
logic 0/5 Vdc, not insulated
OUT3 and OUT4: logic 0/5 Vdc,
not insulated
OUT5: 0/4… 20 mA, 15V max.
-NOT
+24dc, ±20%, 30 mA max. to supply an external transmitter
Up to 3 alarms
Up to 4 alarms
Sensor break, Latching/Blocking, Loop break,
Heater break associated to the timer (if available)
Reference value
--NOT, PWM, Hold
--
Reference value
--
3 red (DO) + 1 green (PWR/COM)
4 red (DO) +1 green (PWR/COM)
---NOT, Toggle, Flip-Flop
6 yellow (DI),
2 red (DO),
1 green (PWR/COM)
--
OP5
NO
OP1
OP2
RS485
N
24V
L
IL
TTL
NO
24V
NPN
Power supply
switch
Connector for
power supply
and serial
communications
bus (female)
NC
24VDC
External
Shunt
2.5Ω
mV
0
5
TTL
NPN
Hz
0
2
Pt100
d8
0
0
9
mA
OP1
OP2
TTL
NO
Hz
NO
Plug with
termination
resistor for
serial comm.s
bus (male)
Configuration
and Supervision
NPN
RS485
DI1
DI2
NC
24V
N
Power
supply
switch
L
TTL
DI5
DI6
DI3
DI4
Connector for power
supply and serial
comm.s bus (female)
NO
0
3
NPN
dimensions
NPN
NO
NO
NO
NPN
NPN
TTL
TTL
d9
Plug with
termination
resistor for
serial comm.s
bus (male)
d7 / d8 / d9
22.5
9 10
99
mV
9 10
OP1
OP2
OP3
OP4
Configuration
Power supply and Supervision
and serial
communications
bus connector
(female)
RS485
5
4
3
2
1
NC
N
L
IL1
External
Shunt
2.5Ω
24V
Power supply
switch
114.5
4 VA max.
155 g approx.
24Vac (-25...+12%), 24Vdc (-15...+25%) (50/60Hz)
5 VA max.
22.5 x 99, depth 114.5 mm
156 g approx.
PWS and COM: 0.08… 1.5 mm² (AWG28-AWG16)
Inputs/Outputs: 0.2… 2.5 mm² (AWG24 - AWG12)
On OMEGA DIN A rail
IP20 (terminal block)
0… 50°C (32… 122°F)/-30… 70°C (-22… 158°F)
5… 95 RH% without condensation
EN61010-1 (IEC1010-1)
mA
4 VA max.
9 10 11
152 g approx.
Pt100
IN2
NO
13 14
IN1
6.3
The dimensions are expressed in mm
mV
NPN
13 14
External
Shunt
2.5Ω
mA
TTL
13 14 15
THERMOSTATS
ANALOGUE
CONTROLLERS
mA
NO
NC
5
DIN RAIL
MOUNTING
CONTROLLERS
Configuration
and Supervision
SPECIAL
CONTROLLERS
AND “CUSTOM”
0
1
2
3
4
5
NC
TTL
°C/°F or engineering units (-999… 9999)
Measure or setpoint retransmission
-(reference value)
Isolated RS485 with Modbus RTU protocol
RS 485 (MASTER or SLAVE) 1200, 2400, 4800, 9600 bit/s 3 wires
Through serial line and supervision software
Note: these modules can be inserted into Profibus DP and DeviceNet nets, together with a DX module, with the possibility of automatic reconfiguration.
166
5
4…20mA
Plug with
termination
resistor for serial
communications
bus (male)
PAC SYSTEMS
OUTPUTS
Code
PREPROGRAMMED
SYSTEMS
1 voltage digital input
(+ 2 configurables)
D7/D8/D9
power supply
24 Vac/Vdc
OUT 1 and out 2
Relay (D7 only)
Relay-Relay
Relay-Logic (D8 and D9 only)
Logic-Logic (D8 and D9 only)
Triac-triac (D8 and D9 only)
Triac-Logic (D8 and D9 only)
Serial communication
RS485
Option 1
Not available
Continuous output (D7 only)
special functions
Not available
instruction Manual
Italian / English
Not available
Option 2
Shunt 1% (D7 and D9 only)
Shunt 0.1% (D7 and D9 only)
Option 3
Not available
Conformal coating
PLC AND
OPERATOR
PANELS
-6 digital inputs in voltage or for
free voltage contacts, in 2 groups
optoisolated (1 and 2 in Hz)
d7
To compose the part number, pls. choose one of the option for each variable
TIMERS
COUNTERS
POWER LIMITERS
1 voltage digital input
--
COnnections
INDICATORS
Digital inputs
Input configuration
D8
--
I/O MODULES
Accuracy
D7
D9
1
2
Thermocouples: L/J/E (0… +600°C / 32… +1112°F),
T (-200…+400°C / -328…+752°F),
K/N (0…+1200°C / 32…+2192°F),
S/R (0... +1600°C / 32...2912°F),
B (0... 1800°C / 32... 3272°F),
Ni-NiMo (0... 1100°C / 32... 2012°F),
W3, W5 (0... 2000°C / 32... 3632°F))
Thermoresistances: PT100 (-99.9... 300.0°C / -99.9... 572.0°F
and -200... 600°C / -328... 1112°F)
Linear signals: 0/10...50 mV; 0/4...20 mA (shunt)
Infrared sensors or programmable on special ranges (custom)
0.25% ±1 digit (thermoelements); 0.1% ±1 digit (mA and mV)
Pt100
SUPERVISION
INPUTS
Number of inputs
COMBUSTION
CONTROL
how to order
features
ACCESSORIES
•analogue and digital acquisition
Modules
•analogue universal transmitter
with alarms
•RS485
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
d7/d8/d9
167
a c q uisi z i o ne e r e gistra z i o ne dati | m o duli di i / o
INDUSTRIAL
CONTROLLERS
analogue i/o
mA, V
mA, V
dual polarity
--
IO-CBAI02UI
CANOpen
8
IO-CBAI04RT
IO-MBAI04RT
IO-CBAI08TC
IO-MBAI08TC
IO-CBAI08HL
IO-MBAI08HL
IO-CBAI08DP
CANOpen
Modbus
CANOpen
Modbus
CANOpen
Modbus
CANOpen
--
Type of outputs
--
Available
60 ms
-Available
RS 485, with dual connector RJ45
16 bit
800V
120 ms
10 ms
IO-MBAI08HLT0-
Modbus
analogue outputs
IO-CBAO08HL
IO-MBAO08HL
IO-CBAO08DP
CANOpen
Modbus
CANOpen
mA, V
V
dual polarity
Available
--
24Vdc (-15...+25%) (50/60Hz)
4 VA max.
110 x 66 mm, depth 76 mm / 220 g approx.
On OMEGA DIN A rail
2 terminal blocks with 11 poles 5.0mm, with screws or CLAMP terminals
IP20 (terminal block)
0... 55°C/ -20… 85°C (32… 131°F / -4… 185°F)
5… 95% RH% without condensation
EN 50081-2, EN 50082-2, EN 61010
20 ms
RTD, Tc, mA, mV,
V, potentiometer
RTD, Tc, mV
RTD, Tc, mV
TC, mV
TC, mV
mA,V unipolar
mA,V unipolar
V dual polarity
mA,V unipolar,
Conformal coating
Thermocouples
2
4
4
8
8
8
8
8
Thermoresistances
Linear signals
Potentiometer
8
mA,V unipolar
mA,V unipolar
V dual polarity
8
8
8
dimensions
analogue i/o
65.8
accessories
12.7
RTD, TC, mV
CABLES
APS2 LOCALBUS76
APS2 LOCALBUS152
APS2 LOCALBUS500
POWER ADAPTOR 3.2 A
POWER ADAPTOR 5 A
PLUG WITH 11 polE CLAMP TERMINALS
PLUG WITH 11 polE SCREW TERMINALS
TERMINAL BLOCK
CONNECTOR RJ45 WITH CAN TERMINAL
76
45.2
152
20.6
22
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
POWER ADAPTORS
APS2 ALDR75-24
APS2 ALDR12024
PLUGS
APS2 SPINAM11
APS2 SPINAV11
TERMINALS AND conneCTORS
APS2 TB2111
APS2 TERMCAN
CaBLE WITH conneCtor RJ45
L=14 cm FOR RS485
CaBLE WITH conneCtor RJ45
L=22 cm FOR RS485
CaBLE WITH conneCtor RJ45
L=50 cm FOR RS485
46.2
TC, mV
DIN RAIL
MOUNTING
CONTROLLERS
L/J (-200… +600°C/-328… +1112°F),
T (-200…+400°C/-328…+752°F),
K (-200…+1370°C/328…+2498°F),
N (0... +1300°C/32... 2372°F),
S (0... +1760°C/ 32... +3200°F),
R (0... +1600°C/32...2912°F)
PT100/PT1000
(-200... +600°C/-328...+1112°F)
0...100 mV, 0...1000 mV,
±100mV, ±1000mV
±50 mV, ±300, ±1.0 V
mA, (0,4… 20 mA), V (0...10V)
100...10K Ω
THERMOSTATS
ANALOGUE
CONTROLLERS
RANGE
SPECIAL
CONTROLLERS
AND “CUSTOM”
channels
I
O
PAC SYSTEMS
description
PREPROGRAMMED
SYSTEMS
Protocol
8
0.1%
2500 V
20 ms
Code
PLC AND
OPERATOR
PANELS
AO-08DP
TIMERS
COUNTERS
POWER LIMITERS
AO-08HL
INDICATORS
AI-08DP
analogue inputs
Accuracy
OUTPUTS
Number of outputs
FUNctional
Modbus protocol
CANOpen protocol
Serial communication
Resolution
Isolation class
Aquisition time
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Protection degree
Operating / storage temperature
Operating humidity
Conformity
AI-08HL
69.3
AI-04RT
4
40.7
AI-08TC
8
46.2
Type of inputs
(see table on next page for input ranges)
AI-02UI
2
Universal:
RTD, TC, mA,
mV, V,
potentiometer
110
INPUTS
Number of inputs
input range
how to order
features
ADVANCED
PROGRAMMER
CONTROLLERS
•analogue aCquisition modules
•up to 8 inputs and 8 outputs
168
169
a c q uisi z i o ne e r e gistra z i o ne dati | m o duli di i / o
INDUSTRIAL
CONTROLLERS
digital i/o
Protection degree
Operating / storage temperature
Operating humidity
Conformity
24 Vdc
2A
500 mA
Available
Available
Available
RS 485, with dual connector RJ45
2500 V
--
800 V
CANOpen
Modbus
CANOpen
CANOpen
24 Vdc PNP
24 Vdc PNP
24 Vdc PNP
24 Vdc PNP
16
16
16
32
CANOpen
Modbus
CANOpen
CANOpen
24 Vdc 0.5 A
24 Vdc 0.5 A
24 Vdc 2 A
24 Vdc 0.5 A
digital i/o
65.8
16
16
16
32
76
45.2
152
22
Note: through modules DX and DY, these instruments can be interfaced on Profibus, CANOpen and DeviceNet nets.
PREPROGRAMMED
SYSTEMS
24Vdc (-15...+25%) (50/60Hz)
4 VA max.
152 x 110 mm,
152 x 110 mm,
76 x 110 mm, depth 66 mm
76 x 110 mm, depth 66 mm
depth 66 mm
depth 66 mm
220 g
360 g
220 g
360 g
On OMEGA DIN A rail
4 terminal blocks
4 terminal blocks
with 11 poles
2 terminal blocks with 11 poles 5.0mm,
with 11 poles
2 terminal blocks with 11 poles 5.0mm,
5.0mm,
with screws or CLAMP terminals
5.0mm,
with screws or CLAMP terminals
with screws
with screws
or CLAMP terminals
or CLAMP terminals
IP20
0... 55°C / -20… 85°C (32… 131°F / -4… 185°F)
5… 95% RH% without condensation
EN 50081-2, EN 50082-2, EN 61010
20.6
PAC SYSTEMS
46.2
800 V
--
500 mA
channels
I
O
THERMOSTATS
ANALOGUE
CONTROLLERS
--
32
description
SPECIAL
CONTROLLERS
AND “CUSTOM”
16
digital inputs
IO-CBDI16LV
IO-MBDI16LV
IO-CBDI16HV
IO-CBDI32LV
digital outputs
IO-CBDO16TS
IO-MBDO16TS
IO-CBDO16TP
IO-CBDO32TS
dimensions
Protocol
69.3
--
Code
40.7
115 Vac
DO-32TS
12.7
24 Vdc
DO-16TP
46.2
16
DO-16TS
accessories
CABLES
APS2 LOCALBUS76
APS2 LOCALBUS152
APS2 LOCALBUS500
POWER ADAPTOR 3.2 A
POWER ADAPTOR 5 A
PLUG WITH 11 polE CLAMP TERMINALS
PLUG WITH 11 polE SCREW TERMINALS
TERMINAL BLOCK
CONNECTOR RJ45 WITH CAN TERMINAL
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
POWER ADAPTORS
APS2 ALDR75-24
APS2 ALDR12024
PLUGS
APS2 SPINAM11
APS2 SPINAV11
TERMINALS AND conneCTORS
APS2 TB2111
APS2 TERMCAN
CaBLE WITH conneCtor RJ45
L=14 cm FOR RS485
CaBLE WITH conneCtor RJ45
L=22 cm FOR RS485
CaBLE WITH conneCtor RJ45
L=50 cm FOR RS485
PLC AND
OPERATOR
PANELS
Connections
DI-32LV
32
24 Vdc
TIMERS
COUNTERS
POWER LIMITERS
Weight
Mounting
DI-16HV
INDICATORS
Dimensions
DI-16LV
110
INPUTS
Number of inputs
Type of inputs
OUTPUTS
Number of outputs
Voltage
Current
FUNctional
Modbus protocol
CANOpen protocol
Serial communication
Isolation class
GENERAL
Power supply
Power consumption
DIN RAIL
MOUNTING
CONTROLLERS
how to order
features
ADVANCED
PROGRAMMER
CONTROLLERS
•digital aCquisition modules
•up to 32 inputs and 32 outputs
•rs485
170
171
a c q uisi z i o ne e r e gistra z i o ne dati | m o duli di i / o
INDUSTRIAL
CONTROLLERS
digital i/o
Protection degree
Operating / storage temperature
Operating humidity
Conformity
Available
RS 485, with dual connector RJ45
4000 V
800 V
--
800 V
24 Vdc (-15...+25%) (50/60 Hz)
4 VA max.
152 x 110 mm,
110 x 76 mm, depth 76 mm
depth 66 mm
360 g
220 g
76 x 110 mm, depth 66 mm
220 g
8
IO-CBDM08TS
CANOpen
IO-MBDM08TS
Modbus
IO-CBDM16TS
CANOpen
IO-CBDM32TS
CANOpen
24 Vdc PNP 24 Vdc 0.5 A
24 Vdc PNP 24 Vdc 0.5 A
25 Vdc PNP 24 Vdc 0.5 A
26 Vdc PNP 24 Vdc 0.5 A
8
76
DIN RAIL
MOUNTING
CONTROLLERS
45.2
152
8
20.6
22
8
8
16
16
THERMOSTATS
ANALOGUE
CONTROLLERS
65.8
The dimensions are expressed in mm
accessories
CABLES
APS2 LOCALBUS76
APS2 LOCALBUS152
APS2 LOCALBUS500
POWER ADAPTORS
APS2 ALDR75-24
APS2 ALDR12024
PLUGS
APS2 SPINAM11
APS2 SPINAV11
TERMINALS AND conneCTORS
APS2 TB2111
APS2 TERMCAN
CaBLE WITH conneCtor RJ45
L=14 cm FOR RS485
CaBLE WITH conneCtor RJ45
L=22 cm FOR RS485
CaBLE WITH conneCtor RJ45
L=50 cm FOR RS485
POWER ADAPTOR 3.2 A
POWER ADAPTOR 5 A
PLUG WITH 11 polE CLAMP TERMINALS
PLUG WITH 11 polE SCREW TERMINALS
TERMINAL BLOCK
CONNECTOR RJ45 WITH CAN TERMINAL
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
Note: through modules DX and DY, these instruments can be interfaced on Profibus, CANOpen and DeviceNet nets.
CANOpen
152 x 110 mm,
depth 66 mm
360 g
4 terminal blocks
4 terminal blocks
with 11 poles
with 11 poles
2 terminal blocks with 11 poles 5.0mm,
5.0mm,
5.0mm,
with screws or CLAMP terminals
with screws
with screws
or CLAMP terminals
or CLAMP terminals
IP20
0... 55°C/ -20… 85°C (32… 131°F / -4… 185°F)
5… 95% RH% without condensation
EN 50081-2, EN 50082-2, EN 61010
2 terminal blocks with 11 poles 5.0mm,
with screws or CLAMP terminals
4
4
IO-CBDO08RL
SPST-NO 2 A
SPST-NO 6 A
4 SPST-NO 2 A
+ 4 SPDT 2 A
DIGITAL I/O
500 mA
Available
CANOpen
CANOpen
SPECIAL
CONTROLLERS
AND “CUSTOM”
--
RELAY OUTPUTS
IO-CBDO04RL
IO-CBDO04TX
digital i/o
PAC SYSTEMS
6A
-24 Vdc
channels
I
O
40.7
250 Vac Relay
-2 A (SPST)
1 A (SSR)
description
46.2
24 Vdc Relay
--
16
Protocol
12.7
8
dimensions
Code
PREPROGRAMMED
SYSTEMS
Connections
24 Vdc
4
4000 V
DM-32TS
16
8
--
250 Vdc Relay
-2 A (SPST)
1 A (SSR)
DM-16TS
PLC AND
OPERATOR
PANELS
Weight
Mounting
DM-08TS
TIMERS
COUNTERS
POWER LIMITERS
Dimensions
DO-08RL
INDICATORS
FUNctional
Modbus protocol
CANOpen protocol
Serial communication
Isolation class
GENERAL
Power supply
Power consumption
DO-04TX
46.2
Current
DO-04RL
110
INPUTS
Number of inputs
Type of inputs
OUTPUTS
Number of outputs
Relay
Voltage
69.3
how to order
features
ADVANCED
PROGRAMMER
CONTROLLERS
•digital acquisition modules
•up to 16 inputs and 16 outputs
•rs485
172
173
a c q uisi z i o ne e r e gistra z i o ne dati | m o duli di i / o
Accuracy
OUTPUT
One
FUNctional
Serial communication
Baud rate
Sampling rate
Range
GENERAL
Power supply
Power consumption
Dimensions / Weight
Connections
Mounting
Operating / storage temperature
Operating humidity
Conformity
4 digital inputs for free voltage contacts
0/4…20 mA or 0/2…10 V
-8x Thermistors PTC KTY 81-121 (990Ω at 25°C)
-or NTC 103AT-2 (10KΩ at 25°C)
or 8x Thermoresistances Pt1000 (1KΩ at 0°C)
±0.5% fs
1 Relay SPST-NO (5A-AC1, 2 A-AC3/250 Vac)
RS485 optoisolated – MODBUS RTU (JBUS) protocol
Programmable between 1200 and 38400 baud
2 samples per second
350 points
According to the used probe
24, 115, 230 Vac ±10% (50/60 Hz)
5 VA approx.
4 DIN rail module 70 x 84 x 60 mm / 210 g approx.
Screw terminal block 2.5 mm²
On OMEGA DIN A rail
0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F)
30…95 RH% without condensation
Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1)
COnnections
Tda04
To compose the part number, pls. choose one of the option for each variable
TDA04
input
0/2…10V
0/4…20 mA
power supply
24 Vac
115 Vac
230 Vac
Code
DIGITAL IN
D1
W
I
D3
D4
RS 485
GND
B
A
OUT
1 2 3 4 5 6 7 8 9 10 11 12
A
C
D
RELAY
TDA04
C
NO
IN1
IN2
IN3
IN4
13 14 15 16 17 18 19 20 21 22 23 24
-
Code
D2
SUPPLY
4..20 mA
TDA08
input
PT1000
NTC
PTC
power supply
24 Vac
115 Vac
230 Vac
DIN RAIL
MOUNTING
CONTROLLERS
TDA08
THERMOSTATS
ANALOGUE
CONTROLLERS
8 probe inputs
TDA04
I
+
I
+
+
(Passive Probe)
0/4..20 mA
0/2..10 V
ext.
gen.
+
ext.
gen.
I
+
+
-
+
I
+
+
-
G
ext.
gen.
+
ext.
gen.
+
-
G
SPECIAL
CONTROLLERS
AND “CUSTOM”
INPUTS
Digital inputs
4 analogue inputs
-
+
G
G
ACTIVE
P
N
E
PAC SYSTEMS
how to order
FEATURES
Tda08
DIGITAL IN
A
C
D
D1
D2
D3
D4
SUPPLY
RS 485
GND
B
PREPROGRAMMED
SYSTEMS
•analogue and digital acquisition
modules
•rs485
•4 or 8 inputs
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
tda
A
OUT
1 2 3 4 5 6 7 8 9 10 11 12
RELAY
TDA08
C
NO
IN2
IN3
IN4
IN5
IN6
IN7
IN8
TIMERS
COUNTERS
POWER LIMITERS
IN1
PLC AND
OPERATOR
PANELS
13 14 15 16 17 18 19 20 21 22 23 24
dimensions
70
27
21
INDICATORS
tda04 / tda08
12
I/O MODULES
1 2 3 4 5 6 7 8 9 10 11 12
SUPERVISION
45
84
60
TDA
13 14 15 16 17 18 19 20 21 22 23 24
ACCESSORIES
COMBUSTION
CONTROL
The dimensions are expressed in mm
174
175
supervision
AutoLink, DX and DY Gateways
SCADA Software for the centralized management and the supervision of plants.
Protocol converters for the integration of the Modbus RTU instrumentation with other field
bus.
176
177
supervision
Functions
DY5121
·
THERMOSTATS
ANALOGUE
CONTROLLERS
·
·
·
·
2
·
·
·
·
·
8
·
·
4
·
·
·
·
·
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
TIMERS
COUNTERS
POWER LIMITERS
PLC AND
OPERATOR
PANELS
PREPROGRAMMED
SYSTEMS
Power supply 24 Vac/Vdc
CE certification + UL approval (listed)
DY
·
SPECIAL
CONTROLLERS
AND “CUSTOM”
Protocol
DX
·
PAC SYSTEMS
Dimensions (mm)
Deltadue module (22.5 x 99 mm)
4 DIN rail module (70 x 85 mm)
Modbus RTU
CANOpen
Profibus DP slave
DeviceNet
Modbus TCP
Multi master
Backup instruments (max.32)
Data transfer (binding)
E-mail and SMS
Webserver
DIN RAIL
MOUNTING
CONTROLLERS
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
a c q uisi z i o ne e r e gistra z i o ne dati | S U P E R V I S I O NE
178
179
INDUSTRIAL
CONTROLLERS
Device autorecognition and project automatic creation (Autolink QuickDIN)
Device autorecognition and project automatic creation (W-Tec)
128, 256, 2048, 62536
Numerics, digitals, strings, composites
Unlimited
Binary, DBF and CSV file types
32
Unlimited
Unlimited
Unlimited, max 10 traces per window
Unlimited and customizables
Up to 999
Events schedulings, remote control, macros, multilanguages, SMS
Ethernet
Stazioni operatore
AUTOLINK
AUTOLINK
AUTOLINK
Controllori
DIN RAIL
MOUNTING
CONTROLLERS
Gestione Fabbrica
THERMOSTATS
ANALOGUE
CONTROLLERS
Serial lines, USB (with adapters), Ethernet
Modbus RTU/ASCII, Modbus TCP, RTU Remote /ASCII Remote - Allen-Bradley Df1 Full Duplex Protocol
For (Plc 3 and Plc 5), Slc 500 - AVEBus - Data Stream - Decom Contrex - Eurotherm Bisynch ASCII Gefran - Cencal - Idec Izumi - Klockner Moeller Sucom - (A and A for Ps4) - Mitsubishi Fr-Cu03 - ODBC
Client - Omron (Fins, Fins in Host Link, Sysmac) - OPC Client - Red Lion PAX-1/8 DIN Counter/Rate Meter Saia (P800 and S-Bus) - Siemens MPI, Prodave MPI Mini, Plc Simatic S5 - S7EV2001, Profibus Mater DP (Tecnint HTE), Profibus MPI and S7 (Applicom), Profibus PPI S7 200 (Applicom), PPI S7 200 (Adapter) Interconnections TCP/IP (Master/Slave) - Raw ASCII Output - Other available drivers
development and runtime Software
for deltaDUE, gammaDUE and sigmaDUE I/O Modbus instruments only
Max 32 instruments
development/Runtime key
LSALINKDIN/USB
max. 32 instruments DIN W-L
development and Runtime software max. 128 variables
development/Runtime key
LSALINKDVS/USB
max. 128 variables DVS-W-ES
development and Runtime software max. 2048 variables
development/Runtime key
LSALINKDVM/USB
max. 2048 variables DVM-W-EM
development and Runtime software max. 65536 variables
development/Runtime key
LSALINKDVX/USB
max. 65536 variables DVX W-EX
Runtime Software
Runtime key max. 65536
LSALINKRNT/USB
variables RNT W-R
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
TIMERS
COUNTERS
POWER LIMITERS
Unique functionalities
Gammadue, Deltadue, Sigmadue
TLK, K, R, Z, Y, X, KM, W
Database and functionalities
Number of variables
Type of variables
Alarms
Trend
Access levels
Synoptic pages
Alarm pages
Trend pages
Recipes
Report
Auxiliary functions
autolink
To compose the part number, pls. choose one of the option for each variable
Pentium II, 512 MB RAM, CD rom, resolution 800x600
Windows 95, 98, 2000, NT, XP, Vista, 7
SPECIAL
CONTROLLERS
AND “CUSTOM”
Drivers
COnnections
PAC SYSTEMS
Hardware and Sofware
Hardware
Supported OS
Communications
Interfaces
PREPROGRAMMED
SYSTEMS
how to order
features
ADVANCED
PROGRAMMER
CONTROLLERS
•Supervision and data acquisition
software
PLC AND
OPERATOR
PANELS
autolink
a c q uisi z i o ne e r e gistra z i o ne dati | S U P E R V I S I O NE
180
181
a c q uisi z i o ne e r e gistra z i o ne dati | S U P E R V I S I O NE
INDUSTRIAL
CONTROLLERS
dx / dy
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Connections
Protection degree
Operating / storage temperature
Operating humidity
Conformity
RS232 standard ( for instrument configuration only)
Ethernet 10/100 Mbaud, RJ45 female connector
RS485 Modubus RTU (max. 115 K baud)
RS485 CANOpen (max. 1 Mb/s)
24Vac (-25...+12%), 24Vdc (-15...+25%) (50/60Hz)
4VA max.
22.5 x 99 mm, depth 114.5 mm / 200 g approx.
On OMEGA DIN A rail
PWS and COM: 0.08… 1.5 mm² (AWG28-AWG16)
Inputs/Outputs: 0.2… 2.5 mm² (AWG24 - AWG12)
IP20 (terminal block)
0... 50°C (32… 122°F) / -20… 70°C (-4… 158°F)
5… 95% RH% without condensation
CE, UL, CSA, EN61010-1 (IEC1010-1)
CE, EN61010-1 (IEC1010-1)
dy
DY
protocol converter
CAN Open/Modbus RTU - Delta2 Case
WEB+Modbus TCP/RTU - 4 DIN Case
TCP/RTU Modbus multiple connection - Delta2 Case
INSTRUCTION MANUAL
Italian / English
English
Code
DIN RAIL
MOUNTING
CONTROLLERS
CodE
THERMOSTATS
ANALOGUE
CONTROLLERS
5
SPECIAL
CONTROLLERS
AND “CUSTOM”
0
1
2
3
4
0
1
5
7
PAC SYSTEMS
RS485 Modbus RTU master protocol (max.19200 baud)
RS485, RS232 Modbus RTU slave protocol,
insulated (max.38400 baud)
RS485 Modbus RTU slave protocol, insulated
(max. 57600 baud)
RS485 Profibus DP slave (max. 12 Mb/s)
dx
DX
Gateway/Manager for Delta2/Gamma2 series
POWER SUPPLY
24 Vac/Vdc
NumBER OF INSTRUMENTS in backup
0 Instruments
4 Instruments
8 Instruments
16 Instruments
32 Instruments
fieldbus communication
No fieldbus
DeviceNet
ModBus
ProfiBus DP
Option 1
Not available
special functions
Not available
INSTRUCTION MANUAL
Italian / English
Not available
Option 2
Not available
Option 3
Not available
Conformal coating
0
PREPROGRAMMED
SYSTEMS
Communications ports
--
Binding (data transfer)
Protocol converter between CANOpen or Modbus TCP
to Modbus RTU
Instruments template
30 pages of 20 variables
64 alarms (e-mail and SMS with external modem,
GSM or GPRS).
A 64 variables log file (CSV), can be periodically send
by e-mail
Trend graphics (if JAVA is installed)
To compose the part number, pls. choose one of the option for each variable
0
0
9
0
PLC AND
OPERATOR
PANELS
WebSCADA functions
--
COnnections
0
3
DY5030
DY5121
DY5220
TIMERS
COUNTERS
POWER LIMITERS
Gateway functions
DY
dimensions
dx / dy
22.5
0
8
INDICATORS
Manager functions
DX
Connected modules (max. 32) configuration and
parameters data backup
Hot swapping, automatic configuration and setup
of the replaced modules.
RS232/485 converter
Protocol converter between Profibus DP SPC3,
DeviceNet and Modbus RTU
I/O MODULES
FUNctional
99
114.5
6.3
SUPERVISION
how to order
features
ADVANCED
PROGRAMMER
CONTROLLERS
•protocol Gateways
ACCESSORIES
COMBUSTION
CONTROL
The dimensions are expressed in mm
182
183
Emission analysis and
combustion control
Energy saving
solutions
184
185
combustion control systems
Combustion and monitorign systems in-situ for civil and industrial power plants composed of
single or multiple boilers.
In-situ probes and analyzer for continuous measurement of oxygen, smoke/air temperature
and carbon monoxide in the flue gases.
186
187
Output range 4… 20mA
Response time
Heating up time
Calibration 2-points
Intervallo di calibrazione
Error indicator
Sensor heating up time
Pluggable screw connectors
ZO2-E-300
ZO2-E-500
ZO2-E-C100
accessories
POWER ADAPTORS
APS2 ALDR75-24
APS2 ALDR12024
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
ZO2-I-500
THERMOSTATS
ANALOGUE
CONTROLLERS
ZO2-I-300
zo2-I 300/500
description
in-situ ZIRCONIUM OXIDE PROBE
WITH integrated electronics L=300 mm
in-situ ZIRCONIUM OXIDE PROBE
WITH integrated electronics L=500 mm
in-situ ZIRCONIUM OXIDE PROBE
WITH EXTERNAL electronics L=300 mm
in-situ ZIRCONIUM OXIDE PROBE
WITH EXTERNAL electronics L=500 mm
in-situ ZIRCONIUM OXIDE PROBE
WITH EXTERNAL electronics L=100 mm
SPECIAL
CONTROLLERS
AND “CUSTOM”
Model
zo2-e-300/500
POWER ADAPTOR 3.2 A
POWER ADAPTOR 5 A
ZO2-E-C100
ACCESSORIES
COMBUSTION
CONTROL
rEMOTE CASE FOR ZO2-E-300/500 AND ZO2-E-C100
SUPERVISION
I/O MODULES
Operation interface
Remote probe connection
To compose the part number, pls. choose one of the option for each variable
PREPROGRAMMED
SYSTEMS
O2%Measuring range
Accuracy
DIMENSIONS
PLC AND
OPERATOR
PANELS
Output
ZO2-I/E
Direct and continuous oxygen content measurement in wet flue gas
Heated zirconium oxide ZrO2
600°C
Stainless Steel AISI 316
1” NPT with 1” NPT sliding nipple
IP 66
-20°C... +55°C
2-3 Kg
24 Vdc ±5%
1.2 A max.
4… 20 mA active or passive output, not isolated
Adjustable via jumpers
0.3% ... 25%
±2%
0... 20.96% , 0... 25%
Adjustable with keys
< 5 sec.
15 min.
1%... 20.9%
Procedure of calibration with keys
12 months
Relay DPST, NC+NO and red led on card
Relay intervention in case of:
O2% <0.3%
probe disconnettion
probe anomaly
heater anomaly
supply voltage anomaly
<15s Automatic temperature control
Power supply 0... 24V
Output 4… 20mA
Fault signal contacts
Sensor wiring (5 wires)
Red led, green led and 3 keys
With supplied cable (3 m)
INDICATORS
GENERAL
Measurement type
Sensor
Max. Heater
Probe material
Process connection
Head protection
Ambient temperature
Weight
Power supply
Power consumption
PAC SYSTEMS
HOW TO ORDER
FEATURES
DIN RAIL
MOUNTING
CONTROLLERS
•zirconiUM oXIDE PROBE
FOR O2 measurement
TIMERS
COUNTERS
POWER LIMITERS
zo2
EMI S S I O N A N A LY S I S A ND COMB U S T I O N CO N T R O L | COMP O NE N T S
188
189
Auxiliary analogue output
Alarm output
FUNCTIONAL
Serial communication (optional)
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
Mounting
Front protection degree
Operating / storage temperature
Operating humidity
Conformity
--
2 Relay NO, 250 Vac/5A programmable
4... 20 mA/0... 10 V control output
4... 20 mA/0... 10 V for O2%
3 Relay NO, 250 Vac/5 A programmable
1 Relay NO, 250 Vac/5 A Failure
RS485 (2 wires) Mod Bus, J Bus
9600 baud max.
100... 240 Vac or 16... 28 Vac (50/60Hz) and 20...30 Vdc
4 VA max.
48 x 96 mm (1/16DIN) - depth 150 mm
Flush in panel in 45 x 92 mm hole
IP 65, mounted on panel with gasket
0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F)
35… 85 RH% without condensation
IEC801-2, 801-3, 801-4
3
5
0
1
2
3
1
2
0
1
2
oxm
DIMENSIONS
oxi / oxm / oxr
48
14
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
4... 20 mA/0... 10 V for O2%
oxi
CODE
THERMOSTATS
ANALOGUE
CONTROLLERS
Main analogue output
4... 20 mA/0... 10 V programmable
for O2%,T smokes, T air, CO2%, �, l
OXI/OXM/OXR
Power supply
230 Vac
24 Vac/Vdc
Serial communication
Not available
20 mA Current Loop Ascon Tecnologic protocol
20 mA Current Loop ModBus protocol
RS485 ModBus protocol
OUT 1
4… 20mA retransmission
0… 10V retransmission
OUT 2 (OXM and OXR only)
Not available
0… 20mA retransmission
0... 10V retransmission
SPECIAL
CONTROLLERS
AND “CUSTOM”
OUTPUTS
To compose the part number, pls. choose one of the option for each variable
PREPROGRAMMED
SYSTEMS
Digital inputs and functions
CONNECTIONS
150
PLC AND
OPERATOR
PANELS
Auxiliary analogue inputs
OXI - Indicator
OXM - Monitor
OXR - controller
Direct in mV from ZO probe (0.2% ±1 digit) or 4... 20 mA linearized in the range 0.0... 20.9%
2 x 4... 20 mA from
-4... 20 mA from boiler load signal
smoke/air temperatures
4 logic inputs:
3 logic inputs: Hold, Fail,
Hold, Fail, fuel switch,
2 logic inputs: Hold and Fail
fuel switch
Set Point mem., Auto/man.
oxr
96
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
The dimensions are expressed in mm
TIMERS
COUNTERS
POWER LIMITERS
INPUTS
Main analogue input
PAC SYSTEMS
HOW TO ORDER
FEATURES
DIN RAIL
MOUNTING
CONTROLLERS
•Indicator, monitor and
controller for combustion
control
INDICATORS
oxi/oxm/oxr
EMI S S I O N A N A LY S I S A ND COMB U S T I O N CO N T R O L | COMP O NE N T S
190
191
Certifications
INDUSTRIAL
CONTROLLERS
2 m + extension 5 m
Pressure: +2 mbar compared to the pressure at chimney
Consumption: 30 m3/h max.
Extension cable for connecting receiver-processing unit 10 or 15 meters
(maximum distance receiver-processing unit without repeater: 17 meters)
Optical alignment unit
Specifiche EMC secondo EN 50081-1/EN 50082-2
Guidelines VDE EN 61010 (IEC 1010-1, VDE 0411), protection class 1, degree of protection IP65
CE (EMC EC Guideline 89/336 EWG, NSP 72/23/EWG
TÜV Certification (Report no. 502/0741/96-20 081751)
Code
Ricevitore: 462 mm
Trasmettitore: 300 mm
160
106
45˚
10
45˚
Ø127
Ø100
90˚
Ø130
78,5
Ø14
8
60
80
Ricevitore: 322
Trasmettitore: 160
164
SPECIAL
CONTROLLERS
AND “CUSTOM”
ZCO-IGM-901-00
Ø39,5
THERMOSTATS
ANALOGUE
CONTROLLERS
Ø74
103,6
164
157
150
19
PAC SYSTEMS
The dimensions are expressed in mm
processing unit
ACCESSORIes
200
Accessories
Extension cable between receiver-processing unit 10 m
Extension cable between receiver-processing unit 15 m
Optical alignment unit
Blower with air filter 0.55Kw 220-240 Vac 50/60 Hz
single-phase
Blower with air filter 0.55Kw 400 Vac 50/60 Hz
three-phase
Code
AZCPROLUNGA10M
AZCPROLUNGA15M
AZC2020436
160
97,5
90
80
Ø8
PREPROGRAMMED
SYSTEMS
15 m
CO ANALYSIS SYSTEM COMPOSITION
1 transmitter
1 receiver
1 processing unit with connecting cable 2 m
1 extension cable between receiver-processing unit 5 m
1 connecting cable between transmitter-receiver 15 m
2 fixing flanges with connection for air instruments
2 tronchetti a saldare
2 kit special nuts and washers
2 seals tronchetti-flanges
1 manual
1 calibration certificate
azcsOFFIANTEMGT230
AZCSOFFIANTEMGT400
PLC AND
OPERATOR
PANELS
Conformity
max. load 5V, 2 mA
Fail and threshold
Rating 1 A , 125 Vdc, 150 Vac max. (30 VA dc or 60 VA ac)
115/230 Vac 50/60 Hz (selectable via jumper)
75 VA
IP 65
probe
To compose the part number, pls. choose one of the option for each variable
CONNECTIONS
zco
The dimensions are expressed in mm
flange
Tronchetto a saldare
Ricevitore
Trasmettitore
Gas
15
Connessione aria strumenti
Cavo di collegamento m 15
Prolunga: 5 m (standard)
10/15 m (opzionali)
max. 17 m
Ø140
Ø76
Unità di elaborazione
I/O MODULES
Ø70
Ø127
130
115/230 Vac
1 ingresso e 1 uscita analogica
1 ingresso e 2 uscite digitali
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
Cavo di collegamento (2 m)
TIMERS
COUNTERS
POWER LIMITERS
Options
0/4... 20 mA/500 Ω max.
DIMENSIONS
332
300
Air instruments
ZCO
0.5 m... 8.0 m (1.6... 26 ft)
Programmable between 0...100 ppm and 0...20000 ppm
5% f.s.
5... 360 s
≤ 300°C (higher temperatures available on request)
–20... +55°C
0... +55°C
0/4... 20 mA/100 Ω
23
GENERAL
Measuring distance (TX-RX)
Measuring range
Accuracy
Response time
Gas temperature
Ambient temperature
Processing unit ambient temperature
1 analogue input for gas temperature
1 isolated analogue output
for CO retransmission
Digital input for plant
2 digital alarm outputs
Outputs current
Power supply
Power consumption
Protection degree
Connection cable between
transmitter-receiver
Connection cable between
receiver-processing unit
DIN RAIL
MOUNTING
CONTROLLERS
HOW TO ORDER
FEATURES
ADVANCED
PROGRAMMER
CONTROLLERS
•CO in-situ analyzer
INDICATORS
zco
EMI S S I O N A N A LY S I S A ND COMB U S T I O N CO N T R O L | COMP O NE N T S
192
193
ACCESSORIes
flexible
solutions
for every
requirements
194
195
accessories
To complete the range...
Together with our products we can also supply all the accessories of your applications:
probes, sockets, gaskets, hole covers, programming keys, signal and protocol converters, front
frame protections, external and current transformers, adapters and more...
196
197
Serial communication
INDUSTRIAL
CONTROLLERS
A01 is able to recovery data from failed instruments too and permits unlimited copies of configuration, error free.
Interface RS485, not insulated
Interface TTL, not insulated
GENERAL
Connections
To compose the part number, pls. choose one of the option for each variable
A01
CONNECTOR
5 pole for 78x35, DIN rail, 72x72 series
3 pole for 48x48 series
POWER ADAPTOR
Available
Not available
kit for pc configuration
USB cable and SW on Cdrom support
Without cable and SW
a01
Code
5
3
E
S
-
The dimensions are expressed in mm
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
TIMERS
COUNTERS
POWER LIMITERS
PLC AND
OPERATOR
PANELS
PREPROGRAMMED
SYSTEMS
Operating / storage temperature
Operating humidity
TTL male connector: JST S 5B-PH-KL
TTL female connector : SAMTEC SQT-105-02-L-S
RS485 connector: Phoenix MC 1,5/3-G-3.5
PWS connector : Dc power Jack 1.3mm
USB connector type: Mini-USB
Dip switch: 4 ways
0… 50°C (32… 122°F) / -20…+70°C (-4… 158°F)
20… 95 RH% without condensation
dimensions
THERMOSTATS
ANALOGUE
CONTROLLERS
Functions
A01
The key is able to “dialogue” with:
* An instrument and to copy parameters from it to the key and vice versa
* A second key and to integrally copy its parameters
* A Personal computer
* A Personal computer and an instrument
SPECIAL
CONTROLLERS
AND “CUSTOM”
FUNctional
DIN RAIL
MOUNTING
CONTROLLERS
how to order
features
ADVANCED
PROGRAMMER
CONTROLLERS
•universal programming key
for Ascon Tecnologic instruments
PAC SYSTEMS
a01
a c c e ss o rie s | a c c e ss o rie s
198
199
a c c e ss o rie s | a c c e ss o rie s
Connections
Protection degree
Mounting
Operating / storage temperature
Operating humidity
Conformity
From USB to RS485 auto powered
From USB to TTL auto powered
Automatic
38400, automatic selection
24 Vac/Vdc ±10% or 100… 240Vac (-15… +10%) (50/60 Hz)
5 VA max.
78x35 mm, depth 77,31 mm / 180 g
PWS: screw terminal block (M3 screws, for cables φ 0.25 to φ 2.5 mm2 or AWG 23 to AWG 14)
RS232/RS485: screw terminal block (M2 screws, for cables φ 0.25 to φ 1.5 mm2 or AWG 23 to AWG 16)
IP20 (terminal block)
On OMEGA DIN A rail
0… 50°C (32… 122°F)/-30…+70°C (-22… 158°F)
20… 85 RH% without condensation
EN61326-1, EN61010-1
CONNECTIONS
To compose the part number, pls. choose one of the option for each variable
A30
Model
From USB to RS485 or TTL
From USB/RS232/RS485 to RS485 or TTL
POWER SUPPLY
24 Vac/Vdc (A30 only)
100… 240 Vac (A30 only)
5V supplied by the USB port (A30U only)
CONNECTIONS
Plug-in screw type
Plug-in screw type, fix part only
a30
code
U
-
THERMOSTATS
ANALOGUE
CONTROLLERS
TX/RX commutation
Baud rate
GENERAL
Power supply
Power consumption
Dimensions / Weight
A30From USB to RS485
From USB to TTL
From RS232 to RS485
From RS232 to TTL
From RS485 to RS485
From RS485 to TTL
L
H
-
SPECIAL
CONTROLLERS
AND “CUSTOM”
Interface type
A30U
E
N
DIMENSIONS
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
TIMERS
COUNTERS
POWER LIMITERS
PLC AND
OPERATOR
PANELS
a30
PAC SYSTEMS
functional
PREPROGRAMMED
SYSTEMS
how to order
features
DIN RAIL
MOUNTING
CONTROLLERS
•signal converter from
USB/RS232/RS485 to RS485/TTL
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
a30
200
201
Power supply for instruments of sigmadue series.
Accessories used to adapt an instrument to an already existing hole, but with
different mechanical measures.
Code
APS2 ALDR75-24
APS2 ALDR12024
Code
BOX 04175
BOX 1002
ARFQ96D
ARFQ96M
description
Adapter for hole from 75 x 32 to 58 x 26 mm
Adapter for hole from 64,4 x 32,4 to 34,3 x 15 mm
Adapter for hole from 96 x 96 to 48 x 96 mm
Adapter for hole from 96 x 96 to 48 x 48 mm
aps2 modem
external gaskets for ip65 protection degree
Modem GSM/GPRS in metallic case.
External gaskets in neoprene mousse able to increase the instrument front
protection degree.
Code
Code
GUAR 6993
GUAR 6927
GUAR 6925
GUAR 6923
GUAR 6973
GUAR 6974
GUAR 6926
APS2 MODEMG100
description
Modem for OMEGA DIN A rail mounting
Dimensions 73 x 54 mm, depth 25 mm
Pws: 230 Vac - 12 Vdc
E-GSM Quad-band 850/900/1800/1900 MHz
ETSI GSM Phase 2+
Class 4 (2W@ 850/900 MHz)
Class 1 (1W@ 1800/1900 MHz)
Antenna GSM: SMA-F connector
PWS: 5.5 - 32 Vdc (micro-FIT connector)
RS232 + Audio conn. female 15-pin Sub-D
PLC AND
OPERATOR
PANELS
TIMERS
COUNTERS
POWER LIMITERS
INDICATORS
description
48 x 48 mm (soft rubber)
48 x 48 mm (Plastic - IP65)
48 x 96 mm (Plastic)
48 x 96 mm (Plastic - IP65)
72 x 72 mm (Plastic)
96 x 96 mm (Plastic)
96 x 96 mm (Plastic)
guar
MODEM GSM/GPRS
202
Code
CAL48x48-M
CAL48x48-IP65
CAL48x96-I
CAL48x96-IP65
CAL72x72-I
CAL96x96-I
CAL96x96-IP65
description
6 port Ethernet Switch - Plastic case
6 port Ethernet Switch - Metallic case
8 port Ethernet Switch - Metallic case
I/O MODULES
Code
APS2 ATOPEH2006
APS2 ATOPEH2306
APS2 ATOPEH2308
Protection covers made of transparent plastic or soft rubber to protect the front of
the instruments. Some models assure the IP65 protection degree.
description
IP65 gasket for 65 x 33 mm front
IP65 gasket for 75 x 33 mm (old style) front
IP65 gasket for 78 x 35 mm (new style) front
IP65 gasket for 48 x 48 mm front
IP65 gasket for 48 x 96 mm front
IP65 gasket for 72 x 72 mm front
IP65 gasket for 181 x 36 mm front
SUPERVISION
PROTEction covers
Industrial Ethernet switches.
COMBUSTION
CONTROL
industrial switches
ACCESSORIES
cal
aps2 atopeh
PREPROGRAMMED
SYSTEMS
PAC SYSTEMS
description
Power supply 75W - 24Vdc - 3.2 A
Power supply 120W - 24Vdc - 5 A
THERMOSTATS
ANALOGUE
CONTROLLERS
ADApters
power supply for SIGMADUE series
SPECIAL
CONTROLLERS
AND “CUSTOM”
box-ar
aps2 aldr
DIN RAIL
MOUNTING
CONTROLLERS
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
A CCE S S O R Ie s | A CCE S S O R Ie s
203
Accessories available with different ratio of current for different instrumentation
demands.
Code
TAPPO 33X75
TAPPO 48x48
TAPPO 48x96
TAPPO 96x96
Code
TR-AMP-100/02
TR-AMP-25/005
TR-AMP-200/04
TR-AMP-50/005
TR-AMP-100/005
description
Cover for 75 x 33 mm hole
Cover for 48 x 48 mm hole
Cover for 48 x 96 mm hole
Cover for 96 x 96 mm hole
description
Ratio 100/0.2
Ratio 25/0.05
Ratio 200/0.4
Ratio 50/0.05
Ratio 100/0.05
DIN RAIL
MOUNTING
CONTROLLERS
current TRAnSFORMers
Accessories used to cover an existing hole that it’s not possible to leave empty for
aesthetic reasons or protection.
THERMOSTATS
ANALOGUE
CONTROLLERS
hole cover
SPECIAL
CONTROLLERS
AND “CUSTOM”
tr-amp
Code
Code
ZOC 02203
ZOC 02805
ZOC 02204
ZOC 02976
ZOC 03110
description
primary/secondary power
24/12 V
115/12V
230/12V
power
3 VA
5 VA
10 VA
3
5
10
Code
tlcov
XX
D
S
--1
111
204
description
instrument to be extended
Part.no to define the instrument to be extended
Position of the instrument
Instrument mounted on the right side
Instrument mounted on the left side
Holes dimensions
Holes with Ø 20 mm
Left hole with Ø 20 mm - Right hole with Ø 22 mm
Left hole with Ø 22 mm - Right hole with Ø 20 mm
Holes with Ø 22 mm
COMBUSTION
CONTROL
Accessories that make it possible to extend the front plate of instruments 78 x 35
mm to 185 x 38 mm. Available also hole plugs and switches to cover the side holes.
ACCESSORIES
extended front plate
SUPERVISION
I/O MODULES
Other models available on request.
description
Octal (IP20)
Octal
Undecal (IP20)
Octal with terminals to be soldered
Octal with screws
PLC AND
OPERATOR
PANELS
Accessories available in different executions: to be soldered, with screws.
A
C
D
tlcov
sockets
Accessories available with different ratio of transformation for different
instrumentation demands.
TIMERS
COUNTERS
POWER LIMITERS
external power transformers
INDICATORS
zoc
tctr
PREPROGRAMMED
SYSTEMS
PAC SYSTEMS
tappo
ADVANCED
PROGRAMMER
CONTROLLERS
INDUSTRIAL
CONTROLLERS
A CCE S S O R Ie s | A CCE S S O R Ie s
205
Here following just some of the possible execution of our thermoelements:
• Probes for machines and small plants
• Flexible probes with MgO insulation
• High pressure probes with replaceable insertion
• High temperature probes with ceramic or methalic sleeve
• Accessories: nipple, thermowell, flanges and so on
• Compensated cables
INDUSTRIAL
CONTROLLERS
ADVANCED
PROGRAMMER
CONTROLLERS
ACCESSORIES
COMBUSTION
CONTROL
SUPERVISION
I/O MODULES
INDICATORS
TIMERS
COUNTERS
POWER LIMITERS
PLC AND
OPERATOR
PANELS
PREPROGRAMMED
SYSTEMS
PAC SYSTEMS
Our technical team is avaiable to discuss your requirements for custom made products. Get in touch with us.
DIN RAIL
MOUNTING
CONTROLLERS
probes and accessories
To choose correctly the probe is often decisive for the good result of the process control.
We, at Ascon Tecnologic puts at your disposition our experience and technical competence with the purpose to find the correct solution to every application problem...
THERMOSTATS
ANALOGUE
CONTROLLERS
•thermocouples
•thermoresistances
•thermistors
•cables and accessories
SPECIAL
CONTROLLERS
AND “CUSTOM”
thermoelements
A CCE S S O R Ie s | A CCE S S O R Ie s
206
207
analytical index
A
j
a01
a30
APS2 ALDR
APS2 Atopeh
APS2 MODEM
ANALOGue i/o
autolink
198
200
202
202
202
168
180
BOX-AR
brewery pac
BWt40
203
118
138
c1
CAL
clima pac
cu02
32
203
116
110
d1
d2
d3
d7
d8
d9
digital i/o
DX
dy
70
70
70
166
166
166
170
182
182
c
d
e51a
86
GUAR
203
g
156
156
158
k30
k30
k31
k32
k38
k39
k31v
k38v
k48
k49
k48v
k85v
k85
k85
km1
km3
kr1
KR3
kx1
KX3
60
72
54
54
54
54
152
152
56
56
154
154
58
74
16
48
20
52
18
50
light pac
120
m1
m2
m3
m4
m5
m81
mp02
34
36
38
38
62
104
106
k
b
e
J1
j3
j5
l
m
mp-d1
mp-d2
mp-d4
108
108
108
openpcs
opMT
oxi
oxm
oxr
112
128
190
190
190
p01
p04
p30
p32
132
126
132
132
tlk41
tlk42
tlk43
tlk72
tlk94
tlk96
tlz35
TLZ35
tp34
tp49
TR-AMP
tt34
tt49
tt73
o
p
q
q1
q3
q5
42
42
64
r38
22
r
t
TAPPO
tc34
tc49
tc73
TCO30
tcpde
TCTR
TDA
ThErmoelements
tlcov
tli40
tlk33
204
142
142
142
96
90
204
174
206
204
150
98
24
24
24
26
30
28
76
84
144
144
205
140
140
140
w
w09
88
x1
x3
x5
40
40
64
x
z
Z31A
zco
zo2
ZOC
82
192
188
205
noteS
ada usa mexico venezuela brazil ireland uk portugal spain france belgium holland luxembourg denmark germany
tzerland austria finland norway sweden slovenia poland hungary czech rep. romania greece algeria tunisia
rocco egypt jordan israel syria south africa CSI latvija kazakhstan turkey singapore hong kong thailand taiwan
na australia new zeland canada usa mexico venezuela brazil ireland uk portugal spain france belgium holland
embourg denmark germany switzerland austria finland norway sweden slovenia poland hungary czech rep.
mania greece algeria tunisia morocco egypt jordan israel syria south africa CSI latvija kazakhstan turkey singapore
ng kong thailand taiwan china australia new zeland canada usa mexico venezuela brazil ireland uk portugal spain
nce belgium holland luxembourg denmark germany switzerland austria finland norway sweden slovenia poland
ngary czech rep. romania greece algeria tunisia morocco egypt jordan israel syria south africa CSI latvija kazakhstan
key singapore
hong kong thailand taiwan china australia new zeland canada usa mexico venezuela brazil ireland
PRODUCTION
portugal spain france belgium holland luxembourg denmark germany switzerland austria finland norway sweden
venia poland hungary czech rep. romania greece algeria tunisia morocco egypt jordan israel syria south africa
latvija kazakhstan
turkey singapore hong kong thailand taiwan china australia new zeland canada usa mexico
SUBSIDIARIES
ezuela brazil ireland uk portugal spain france belgium holland luxembourg denmark germany switzerland austria
land norway sweden slovenia poland hungary czech rep. romania greece algeria tunisia morocco egypt jordan
ael syria south africa CSI latvija kazakhstan turkey singapore hong kong thailand taiwan china australia new
HEADQUARTERS
and canada usa
mexico venezuela brazil ireland uk portugal spain france belgium holland luxembourg denmark
rmany switzerland austria finland norway sweden slovenia poland hungary czech rep. romania greece algeria
the group
Ascon Tecnologic s.r.l.
viale Indipendenza, 56 · 27029 Vigevano (PV) Italy
tel +39 0381 69 871 · fax +39 0381 69 87 30
info@ascontecnologic.com
www.ascontecnologic.com
Tecnologic Uk ltd
Ascon Polska sp. z.o.o.
Coelmatic ltda
Unit No.1 Farnborough Business Centre
Eelmoor Road · Farnborough
Hampshire · GU14 7xa
tel +44 125 2377 600 · fax +44 125 2377 60
sales@tecnologicuk.co.uk
www.t-uk.co.uk
Kochcice ul. Kochanowicka 43
42-713 Kochanowice
tel +48 34 35 33 619 · fax +48 34 35 33 884
info@ascon.pl
www.ascon.pl
Al. Vincente Pinzon, 173 - 9° andar
Sao Paulo · SP - CEP 04547 - 130
tel +55 11 2066-3211 · fax +55 11 3046-8601
info@coel.com.br
www.coelmatic.com.br
Ascon Tecnologic France
Ascon Tecnologic North America
Coelmatic Sapi Sa de Cv
BP 76 · 77202 · Marne La vallee Cedex 1
tel +33 1 64 30 62 62 · fax +33 1 64 30 84 98
info@ascontecnologic.fr
www.ascontecnologic.com/fr
1111 Brook Park Road
Cleveland · OH 44109
tel +1 216 485 83 50 · Fax +1 216 398 85 53
info@ascontec-na.com
www.ascontecnologic.com/en
Paseo De Los Cipreses,
3720 Del Paseo Residencial,
Monterrey Nuevo León · CP. 64920
tel +52 81 8104 1012
info@coelmatic.com.mx
www.coelmatic.com.mx
Printed in October 2013
Printed by:
Tipolitografia Vaccarone - Vigevano (PV)
Graphic project:
www.elever.it