process catalogue 2013/2014
Transcription
process catalogue 2013/2014
PROCESS CATALOGUE 2013/2014 INDex INDUSTRIAL automation INDUSTRIAL controllers km1 kx1 kr1 r38 tlk41 tlk42 tlk43 tlk72 tlk96 tlk94 c1 m1 m2 m3 m4 x1 x3 q1 q3 advanced programmer controllers km3 KX3 KR3 k31 k32 k38 k39 k48 k49 k85 k30 m5 x5 q5 din rail mounting controllers d1 d2 d3 k30 k85 11 13 16 18 20 22 24 24 24 26 28 30 32 34 36 38 38 40 40 42 42 45 48 50 52 54 54 54 54 56 56 58 60 62 64 64 67 70 70 70 72 74 tlz35 Thermostats - analogue controllers Z31A TLZ35 e51a w09 tcpde special controllers and “custom” TCO30 tlk33 pac systems m81 mp02 mp-d1 mp-d2 mp-d4 cu02 openpcs pre-programmed systems clima pac brewery pac light pac operator panells p04 opMT p01 p30 p32 timer - counters - power limiters BWt40 tt34 tt49 tt73 tc34 tc49 tc73 tp34 tp49 indicators tli40 k31v k38v 76 79 82 84 86 88 90 93 96 98 101 104 106 108 108 108 110 112 115 116 118 120 123 126 128 132 132 132 135 138 140 140 140 142 142 142 144 144 147 150 152 152 k48v k85v J1 / j3 j5 ACQUISItion and data recording i/o modules d7 d8 d9 ANALOGue i/o digital i/o TDA supervision autolink DX dy emission ANALySIs and combustion CONTROL analysis systems zo2 oxi oxm oxr zco ACCESSORIes accessories a01 a30 APS2 ALDR APS2 Atopeh aps2 modem BOX-AR CAL GUAR TAPPO TCTR tlcov TR-AMP ZOC Thermoelements 154 154 156 158 161 163 166 166 166 168 170 174 177 180 182 182 185 187 188 190 190 190 192 195 197 198 200 202 202 202 203 203 203 204 204 204 205 205 206 company profile Ascon Tecnologic is an Italian company that develops, manufactures and commercializes a complete range of products for the regulation and automation of machinery and systems in the manufacturing and processing sectors as well as that of industrial and commercial refrigeration. The group Ascon Tecnologic has more than 200 employees and, in its productive plants, realizes every year over a million of instruments. Ascon Tecnologic operates in over 50 countries with 6 branches, its own agents and a distribution network, offering clients sales and after-sales assistance. Manufacturing unit, Manaus (Brazil). Headquarters, offices, R&D, Manufacturing unit, Vigevano (Italy). quality certification / safety and APPROVALS Ascon Tecnologic S.r.l. has obtained the certification of “Quality System” in conformity to UNI EN ISO 9001:2008 released by the corporate certifier Det Norske Veritas Italy S.r.l. The instruments are developped for the use in conformity to the actual compliance, as concern the CE mark according to Directives 2006/95/CE (Low Voltage) and 2004/108/CE (EMC). The applicable rules, according to the model, are: Safety - EN61010-1 - EN60730-1 - UL873 for use conforming as foreseen by Underwriters Laboratory Inc. (only for approved instruments). EMC EN61326-1 Remarks: please make reference to the documentation and the individual certifications for details of the applicable norms. industrial AUTOMAtion Flexible control 10 11 INDUSTRIAL controllers Evolution...cubed ! Experience and innovation are at the base of this range of products, able to answer to any demand of performances. From the “entry level” controller with innovative “Sensitive-Touch” keyboard to the more sophisticated microprocessor based controllers with PID algorithm, in different sizes, standard and not. New KUBE line: more and more in less space! Pocket size, energy saving functions and advanced features. 12 13 INDUSTRIAL controllers Control · · · TLK72 TLK96 TLK94 C1 M1 M2 M3 M4 · · · · X1 X3 · · Q1 Q3 · · · 4 4 4 · · · · · · · · · · · · · · · · · 2 2 2 4 4 4 · · · · · · · · · · · · · · · · · · · · 4 · 4 · 4 · · · · · 2 4 4 · · · · · · · · · · · · · · · · · · 1 · 4 2 · 4 4 · · · · · · · · 3 2 · · · · · · · · · · · · · · · · · · · · · · · · 4 4 4 · 4 · 4 · 4 · 4 · 4 · 4 · 4 · · · · · · · · · · · · · · · · · · · · · · · 3 1 · · 4 1 · · 3 · 4 1 · · 4 1 · · 1 · 4 1 · · 3 1 · · 1 · 3 · 3 · 4 1 · SPECIAL CONTROLLERS AND “CUSTOM” · PAC SYSTEMS · THERMOSTATS ANALOGUE CONTROLLERS · · 2 · 5 2 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 4 1 · · · · · · · · · · · · · · · · · ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES RS485 Timer on board Programmer CE certification UL approval ENEC approval TLK43 · 4 12 Vac/Vdc 24 Vac/Vdc 100… 240 Vac ON/OFF and PID Servomotor control TLK42 · · Universal input PTC-NTC J-K S S-R-T Pt100 ∆T PT100 Pt1000 IR sensors Digital For CT TLK41 · · · Relay or voltage for SSR drive outputs Analogue current or voltage outputs Measuring or Set Point retransmission Power supply R38 · PREPROGRAMMED SYSTEMS Input KR1 · PLC AND OPERATOR PANELS 3 dynamic colour dual LED display Single display Dual display Digit "Sensitive Touch" keyboard KX1 TIMERS COUNTERS POWER LIMITERS Dimensions (mm) KM1 78 x 35 24 x 48 48 x 48 48 x 96 72 x 72 96 x 96 INDICATORS features DIN RAIL MOUNTING CONTROLLERS ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs 14 15 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs Up to 4 OUT 1: Relay SPST-NO 4A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10% OUT 2: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10% OUT 3: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 110.5V min. @ 15mA ±10% OUT 4 programmable: voltage output to drive SSR 13V max. @ 1mA, 10.5V min. @ 22mA ±10% or transmitter supply or 2nd digital input FUNCTIONAL Control 24 Vac/Vdc ± 10%, 100… 240 Vac/Vdc -15%/+ 10% (50/60 Hz) 7 VA max. 48 x 48 mm (1/16DIN) - depth 63 mm / 125 g Flush in panel in 45 x 45 mm hole 16 screw terminals 2.5 mm² (AWG22…. AWG14) fix, plug-in or clamp type IP 65, mounted on panel with gasket 0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F) 20… 95 RH%, without condensation EN 61010-1, EN 61326 DIN RAIL MOUNTING CONTROLLERS Close Line 100... 240 VAC/ 20... 30 VDC Neutral 12 VDC (note) Transducer mV, V mA Thermocouple TERMINALS 12 VDC (note) L Stripped wire L 5.5 mm - 0.21 in. Pin connector: 1.4 mm - 0.055 in. max. q PV Note: Terminal 4 can be programmed as: - Digital Input (DI2) connecting a free of voltage contact between terminals 4 and 16 - 0... 12 V SSR Drive Output (OP4) connecting the load between terminals 4 and 16 - 12 Vdc (20 mA) transmitter power supply connecting the transmitter between terminals 4 and 1 Transducer Pt1000/NTC/PTC Pt100 R O dimensions km1 R O - 48 SPECIAL CONTROLLERS AND “CUSTOM” PV THERMOSTATS ANALOGUE CONTROLLERS OP3 * 11 14 48 D S E N M - Terminals 18 10 15 The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION Alarms Set Point Serial communication Baud rate Working hours counters Wattmeter function EVOogreen Timer (optional) GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity PID single or double action, ON/OFF, ON/OFF with Neutral Zone Autotuning and Selftuning algorithms, Overshoot control 3 alarms programmable as absolute, deviation, band 4 programmable Set Points TTL (standard) + RS485 (optional), ModBus RTU protocol 1200… 38400 baud A cumulative non-erasable counter and a second one resettable with alarm Instantaneous power, time consumption Stand-by mode of display, selectable Independent with 5 function modes OP4 (note) Analogue input 2 wires Passive 4... 20 mA R O - Open DI2 (note) 3 wires C E OP2 * PAC SYSTEMS OUTPUTS L H DI1 OP1 RS485 T PLC AND OPERATOR PANELS Digital inputs Code TIMERS COUNTERS POWER LIMITERS Accuracy KM1 Version Controller Controller + Timer Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC, RTD, mA, V, mV/digital input 1 TC, NTC, PTC, mA, V, mV/digital input 1 OUT 1 Relay SPST 4A Vdc for SSR driving OUT 2 Relay SPST 2A Vdc for SSR driving Not available OUT 3 Relay SPST 2A Vdc for SSR driving Not available IN/OUT 4 Digital input 2 or digital output or transmitter supply RS485 Available Not available connection Plug-in screw type Plug-in screw type, fix part only Clamp type Fix screw type (standard) INDICATORS Universal Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F), S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F) Infrared sensors: J or K Thermoresistances: 3 wires Pt 100 and 2 wires Pt 1000 (-200... 850°C/-328... 1562°F) Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F), S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F) Infrared sensors: J or K Thermistors: PTC KTY81-121 (-55... +150°C/-67... 302°F), NTC 103 AT2 (-50... +110°C/-58... 230°F) Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V ± 0.5% span ±1 digit, (±1% span ±1 digit for T/c S type) 1 or 2 according to instrument’s part number (the 2nd digital input is alternative to OUT 4) km1 To compose the part number, pls. choose one of the option for each variable I/O MODULES INPUTS COnnections 14 Dual LED KM1 Main display: 4 digit h 15.5 mm. 3 colours: red, green and amber Secondary display: 4 green digit, h 7 mm 48 DISPLAY PREPROGRAMMED SYSTEMS how to order features 45 •3 dynamic colour led display •Independent Timer •WORKING hours counter •Wattmeter function ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS km1 16 17 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs OUTPUTS Up to 4 OUT 1: Relay SPST-NO 4A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10% OUT 2: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10% OUT 3: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 110.5V min. @ 15mA ±10% OUT 4 programmable: voltage output to drive SSR 13V max. @ 1mA, 10.5V min. @ 22mA ±10% or transmitter supply or 2nd digital input FUNCTIONAL Control 24 Vac/Vdc ± 10%, 100… 240 Vac/Vdc -15%/+ 10% (50/60 Hz) 7 VA max. 48 x 96 mm (1/8 DIN) - depth 76 mm / 260 g Flush in panel in 45 x 93 mm hole 16 screw terminals 2.5 mm² (AWG22…. AWG14) fix, plug-in or clamp type IP 65, mounted on panel with gasket 0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F) 20… 95 RH%, without condensation EN 61010-1, EN 61326 L H OP3 * C NO Open OP2 * C NA RS485 Analogue input C E OP1 C KX3 only DI1 Pt1000/NTC/PTC Pt100 DI2 (note) Passive 4... 20 mA 3 wires 12 Vdc (note) R O R O - DIN RAIL MOUNTING CONTROLLERS NO Close THERMOSTATS ANALOGUE CONTROLLERS q Note: Terminal 4 can be programmed as: - Digital Input (DI2) connecting a free of voltage contact between terminals 4 and 5 - 0... 12 V SSR Drive Output (OP4) connecting the load between terminals 4 and 5 - 12 Vdc (20 mA) transmitter power supply connecting the transmitter between terminals 4 and 1 SPECIAL CONTROLLERS AND “CUSTOM” T 100... 240 Vac/ Fase 20... 30 Vdc Neutral L Stripped wire L 5.5 mm - 0.21 in. Pin connector: 1.4 mm - 0.055 in. max. Transducer OP4 (note) 2 wires PV PV Transducer 12 Vdc (note) mV, V mA Thermocouple DIMENSIONS kx1 R O - 48 11 62 14 18 D S E N M The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION Alarms Set Point Serial communication Baud rate Working hours counters Wattmeter function EVOogreen Timer (optional) GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity PID single or double action, ON/OFF, ON/OFF with Neutral Zone Autotuning and Selftuning algorithms, Overshoot control 3 alarms programmable as absolute, deviation, band 4 programmable Set Points TTL (standard) + RS485 (optional), ModBus RTU protocol 1200… 38400 baud A cumulative non-erasable counter and a second one resettable with alarm Instantaneous power, time consumption Stand-by mode of display, selectable Independent with 5 function modes TERMINALS PAC SYSTEMS Digital inputs Code PLC AND OPERATOR PANELS Accuracy KX1 Version Controller Controller + Timer Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC, RTD, mA, V, mV/digital input 1 TC, NTC, PTC, mA, V, mV/digital input 1 OUT 1 Relay SPST 4A Vdc for SSR driving OUT 2 Relay SPST 2A Vdc for SSR driving Not available OUT 3 Relay SPST 2A Vdc for SSR driving Not available IN/OUT 4 Digital input 2 or digital output or transmitter supply RS485 Available Not available connection Plug-in screw type Plug-in screw type, fix part only Clamp type Fix screw type (standard) TIMERS COUNTERS POWER LIMITERS Universal Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F), S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F) Infrared sensors: J or K Thermoresistances: 3 wires Pt 100 and 2 wires Pt 1000 (-200... 850°C/-328... 1562°F) Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F), S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F) Infrared sensors: J or K Thermistors: PTC KTY81-121 (-55... +150°C/-67... 302°F), NTC 103 AT2 (-50... +110°C/-58... 230°F) Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V ± 0.5% span ±1 digit, (±1% span ±1 digit for T/c S type) 1 or 2 according to instrument’s part number (the 2nd digital input is alternative to OUT 4) kx1 To compose the part number, pls. choose one of the option for each variable INDICATORS INPUTS CONNECTIONS I/O MODULES Dual LED KX1 Main display: 4 digit h 15.5 mm. 3 colours: red, green and amber Secondary display: 4 green digit, h 10 mm + 20 segments Bargraph 96 DISPLAY PREPROGRAMMED SYSTEMS HOW TO ORDER features 89 •3 dynamic colour led display •Independent Timer •WORKING hours counter •Wattmeter function ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS kx1 18 19 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs Up to 4 OUT 1: Relay SPDT-NO 4A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10% OUT 2: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10% OUT 3: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 110.5V min. @ 15mA ±10% OUT 4 programmable: voltage output to drive SSR 13V max. @ 1mA, 10.5V min. @ 22mA ±10% or transmitter supply or 2nd digital input FUNCTIONAL Control 24 Vac/Vdc ± 10%, 100… 240 Vac/Vdc -15%/+ 10% (50/60 Hz) 7 VA max. 72 x 33 mm - depth 78 mm + 14 mm (plug-in terminals) / 200 g Flush in panel in 69 x 28 mm hole 16 screw terminals 2.5 mm² (AWG22…. AWG14) fix, plug-in or clamp type IP 65, mounted on panel with gasket 0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F) 20… 95 RH%, without condensation EN 61010-1, EN 61326 mV, V 12Vdc (note) mA Pt1000/NTC/PTC DI2 (note) Thermocouple Pt100 OP1 OP2 * TERMINALS L Pin connector: Stripped wire 1.4 mm - 0.055 in. max. L 5.5 mm - 0.21 in. q Neutral Line C NO 100... 240VAC/ Close 20... 30VDC C NO C NC NO Open Note: Terminal 4 can be programmed as: - Digital Input (DI2) connecting a free of voltage contact between terminals 4 and 11 - 0... 12 V SSR Drive Output (OP4) connecting the load between terminals 4 and 11 - 12 Vdc (20 mA) transmitter power supply connecting the transmitter between terminals 4 and 1 R O R O - DI1 OP4 (note) OP3 * C E THERMOSTATS ANALOGUE CONTROLLERS 2Vdc (note) L H RS485 Transmitter 2 wires SPECIAL CONTROLLERS AND “CUSTOM” 3 wires DIMENSIONS kR1 R O D 78 S - 5 64 14 18 E N M The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION Alarms Set Point Serial communication Baud rate Working hours counters Wattmeter function EVOogreen Timer (optional) GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity PID single or double action, ON/OFF, ON/OFF with Neutral Zone Autotuning and Selftuning algorithms, Overshoot control 3 alarms programmable as absolute, deviation, band 4 programmable Set Points TTL (standard) + RS485 (optional), ModBus RTU protocol 1200… 38400 baud A cumulative non-erasable counter and a second one resettable with alarm Instantaneous power, time consumption Stand-by mode of display, selectable Independent with 5 function modes T Passive 4... 20 mA PV PV PAC SYSTEMS OUTPUTS Analogue input Transmitter PREPROGRAMMED SYSTEMS Digital inputs CODE PLC AND OPERATOR PANELS Accuracy KR1 Version Controller Controller + Timer Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC, RTD, mA, V, mV/digital input 1 TC, NTC, PTC, mA, V, mV/digital input 1 OUT 1 Relay SPDT 4A Vdc for SSR driving OUT 2 Relay SPST 2A Vdc for SSR driving Not available OUT 3 Relay SPST 2A Vdc for SSR driving Not available OUT 4 Digital input 2 or digital output or transmitter supply RS485 Available Not available connection Plug-in screw type Plug-in screw type, fix part only Clamp type Fix screw type (standard) TIMERS COUNTERS POWER LIMITERS Universal Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F), S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F) Infrared sensors: J or K Thermoresistances: 3 wires Pt 100 and 2 wires Pt 1000 (-200... 850°C/-328... 1562°F) Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F), S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F) Infrared sensors: J or K Thermistors: PTC KTY81-121 (-55... +150°C/-67... 302°F), NTC 103 AT2 (-50... +110°C/-58... 230°F) Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V ± 0.5% span ±1 digit, (±1% span ±1 digit for T/c S type) 1 or 2 according to instrument’s part number (the 2nd digital input is alternative to OUT 4) kr1 To compose the part number, pls. choose one of the option for each variable INDICATORS INPUTS CONNECTIONS I/O MODULES Dual LED KR1 Main display: 4 digit h 11.7 mm. 3 colours: red, green and amber Secondary display: 4 green digit, h 7 mm 35 DISPLAY DIN RAIL MOUNTING CONTROLLERS HOW TO ORDER features 28 •3 dynamic colour led display •Independent Timer •WORKING hours counter •Wattmeter function ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS kr1 20 21 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs INDUSTRIAL CONTROLLERS r38 S - F L H C 1 + NC NO 2 3 O UT2 C 4 DIN RAIL MOUNTING CONTROLLERS + NC NO 5 IN PUTS 6 O UT1 7 8 10 11 12 SU PPLY F A T THERMOSTATS ANALOGUE CONTROLLERS RELAYS: 8A-AC 1 (6A-AC 3) / 250VAC SSR : 10 V DC/ 20 mA PTC -NTC Pt100/ Pt 1000 + tc R O - PAC SYSTEMS R O DIMENSIONS r38 B 78 E N - 6 12.2 78 (*) Capacitive Touch screen keyboard 64 ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm PREPROGRAMMED SYSTEMS 12 Vac/Vdc, 24 Vac, 100… 240 Vac/Vdc ±10% (50/60 Hz) 6 VA approx. 78 x 35 mm - depth 64 mm / 180 g approx. Mechanical or “Sensitive Touch” Screw terminal block 2 x 1 mm² plug-in connector or fix type Flush in panel in 71 x 29 mm hole IP 65, mounted on panel with gasket 0... +50°C (32... 122°F) / -30... +70°C (-22... +158°F) 20… 85 RH%, without condensation Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1) CODE PLC AND OPERATOR PANELS ON/OFF single and double action, Neutral Zone, PID, programmable Autotuning 1 sec TTL ModBus 9600 baud R38 keyboard Mechanical Sensitive-Touch (*) Power supply 12 Vac/Vdc 24 Vac/Vdc 100… 240 Vac/Vdc INPUT TC (J,K) PT100 (2 wires only) PTC/NTC/PT1000 OUT 1 Relay SPDT 8A-AC1 Vdc for SSR driving OUT 2 Relay SPDT 8A-AC1 Vdc for SSR driving Not available Buzzer (internal) Available Tipo Collegamento Plug-in screw type Plug-in screw type, fix part only Fix screw type (standard) TIMERS COUNTERS POWER LIMITERS OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or voltage to drive SSR 20mA/12 Vdc ±20% 20 mA max. 12 Vdc/20 mA max. R38 To compose the part number, pls. choose one of the option for each variable 35 Accuracy OUTPUTS Up to 2 Auxiliary power supply FUNCTIONAL Control PID functions Sampling rate Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Keyboard Connections Mounting Front protection degree Operating / storage temperature Operating humidity Conformity Thermocouples J, K (-40... +999°C / -40… +999°F) or Infrared sensors: J or K Thermoresistances Pt 100 2 wires (-50.0... +850°C / -58... +999°F) autoranging Thermoresistances Pt 1000 2 wires (-50.0... +850°C / -58... +999°F) autoranging + Thermistors PTC KTY 81-121 (990Ω at 25°C) (-50.0... +150°C / -58.0 a 302°F ) autoranging e Thermistors NTC 103AT-2 (10kΩ at 25°C) (-50.0... +109°C / -58.0... +228°F ) ± 0.5% span ±1 digit@ 25°C CONNECTIONS 28 3 different configurations R38 4 red or blue digit, h 12 mm 35 DISPLAY Single INPUTS SPECIAL CONTROLLERS AND “CUSTOM” HOW TO ORDER features ADVANCED PROGRAMMER CONTROLLERS •“Sensitive Touch” keyboard •easy programming 22 23 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs Accuracy Current transformer (CT) input Digital input OUTPUTS Up to 4 Auxiliary power supply Current (as alternative to Relay output) Voltage (as alternative to Relay output) FUNCTIONAL Control PID functions Multi Set Point Servomotor control Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity Thermoresistances: Pt100 and Pt1000 Thermoresistances: Pt100 3 wires (-200... +850°C/-328... +1562°F 3 wires or -199.9... +850.0°C/-199.9... +999.9°F) (see table next page for according to EN 60751/A2, classe A or B temperature ranges) Thermistors PTC KTY 81-121 (990 kΩ at 25°C) (-55... +150°C/-67... +302°F or -55.0... +150.0°C -67.0... +302.0°F) and NTC 103AT-2 (10Ω at 25°C) (-50... +110°C/-58... +230°F or -50.0... +110.0°C/-58.0... +230.0°F) Linear signals: 0/10... 50 mV, 0/12... 60 mV, 0/4... 20 mA, 0/1... 5 V, 0/2... 10 V ±0.15% fs CT 50 mA max. -optoisolated OUT 1: Relay SPST-NO (5 A-AC1, 2 A-AC3/250 Vac) or 7 mA/14 Vdc 20 mA max. to drive SSR OUT 2, OUT 3 and OUT 4: Relay SPST-NO (3 A-AC1, 1,5 A-AC3/250 Vac) or 7 mA/14 Vdc 20 mA max. to drive SSR 12 Vdc/20 mA max. OUT 1 and OUT 2: 0/4… 20 mA. -OUT 1 and OUT 2: 0/2… 10 V ON/OFF, Neutral Zone, PID single and double action AUTOTUNING, FAST TUNING, Selftuning Up to 4 pre-programmable Set Point -3 points -On analogue output RS485 with ModBus-RTU (JBUS) protocol -1200… 38400 baud, programmable 24 Vac/Vdc, 100… 240 Vac/Vdc ±10% (50/60 Hz) 10 VA approx. 48 x 48 mm (1/16DIN) - depth 98 mm / 190 g approx. Flush in panel in 45 x 45 mm hole Screw terminal block 2 x 1 mm² IP 65, mounted on panel with gasket 0… +50°C (32… +122°F) /-25… +60°C (-13… +140°F) 30… 95 RH% without condensation Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1) ANALOG. (TLK43) TC +1 PTC - + + + 7 8 NO C OUT4 OUT3 + + - NO NO 9 10 11 12 - + NO C 13 14 15 16 17 18 GND B SUPPLY DIG. IN (TLK43) A RS485 4..20 mA PASSIVE (2 wires) + - 0/4..20 mA ACTIVE 0..50/60 mV 0/1..5 V 0/2..10 V tlk43 temperature ranges INPUT tc K tc B tc E tc L tc N tc R tc T tc C Pt100 (IEC) Out3 Out4 6 C OUT1 G TEMPERATURE RANGES Pt1000 (IEC) The dimensions are expressed in mm 24 I Ingrared sensors (ZIS) 98 5 - + - 4..20 mA ACTIVE + - tc S 44.5 48 SET + OUT 12 VDC (Max 20 mA) - S I - AT ST = 4 TA HB PTC (KTY81-121) - 3 NTC tc J TLK41 / tlk42 / tlk43 Out1 Out2 - OUT2 + G Pt100 R O - DIMENSIONS 9.5 2 ext. gen.+ Notes: TLK41-TLK42-TLK43: OUT 3 and OUT 4 have to be of the same type (both R or O). CT INPUT: this function has to be always associated to an output (R or O). TLK43: Analogue output and CT function are mutually exlcusive. Digital input is always available when RS485 option is provided. RS485 and OUT 4 are mutally exclusive. 48 RELAY INPUT R O C V - H - - SSR R O C V R O - DIN RAIL MOUNTING CONTROLLERS - L H NTC (103-AT2) THERMOSTATS ANALOGUE CONTROLLERS ANALOG.: 0/4 ..20 mA - 0/2..10 V SSR: 7mA/14VDC RELAY OUT1: 5A-AC1 (2A-AC3) 250VAC RELAYS OUT2,3,4: 3A-AC1 (1A-AC3) 250VAC SPECIAL CONTROLLERS AND “CUSTOM” Universal Thermocouples: J, K, S, B, C, E, L, N, R, T (see table next page for temperature ranges) CODE without D.P. -160 ... 1000 °C - 256 ... 1832 °F -100 ... 1370 °C - 148 ... 2498 °F 0 ... 1760 °C 32 ... 3200 °F 72 ... 1820 °C 162 ... 3308 °F -150 ... 750 °C -252 ... 1382 °F -150 ... 900 °C -252 ... 1652 °F -250 ... 1300 °C -418 ... 2372 °F -50 ... 1760 °C -58 ... 3200 °F -250 ... 400 °C -418 ... 752 °F 0 ... 2320 °C 32 ... 4208 °F -46 ... 785 °C -50 ... 1445 °F -200 ... 500 °C -328 ... 932 °F -200 ... 850 °C -328 ... 1562 °F -55 ... 150 °C -67 ... 302 °F -50 ... 110 °C -58 ... 230 °F with D.P. -160.0 ... 999.9 °C -199.9 ... 999.9 °F -100.0 ... 999.9 °C -148.0 ... 999.9 °F 0.0 ... 999.9 °C 32.0 ... 999.9 °F 72.0 ... 999.9 °C 162.0 ... 999.9 °F -150.0 ... 750.0 °C -199.9 ... 999.9 °F -150.0 ... 900.0 °C -199.9 ... 999.9 °F -199.9 ... 999.9 °C -199.9 ... 999.9 °F -50.0 ... 999.9 °C -58.0 ... 999.9 °F -199.9 ... 400.0 °C -199.9 ... 752.0 °F 0.0 ... 999.9 °C 32.0 ... 999.9 °F -46.0 ... 785.0 °C -50.8 ... 999.9 °F -199.9 ... 500.0 °C -199.9 ... 932.0 °F -199.9 ... 850.0 °C -199.9 ... 999.9 °F -55.0 ... 150.0 °C -67.0 ...302.0 °F -50.0 ... 110.0 °C -58.0 ... 230.0 °F PAC SYSTEMS Thermocouples: J (-160... +1000°C/-256... +1832°F or -160.0... +999.9°C/-199.9... +999.9°F ), K (-100... +1370°C/- 148... +2498°F or -100.0... +999.9°C/-148.0... +999.9°F), S (0... +1760°C/32... +3200°F or 0.0... 999.9°C/32.0... +999.9°F) Infrared sensors: J or K TLK41 / TLK42 / TLK43 Power supply 24 Vac/Vdc 100... 240 Vac OUT 1 Relay Voltage for SSR driving 0/4... 20mA (TLK43 only) 0/2... 10V (TLK43 only) OUT 2 Relay Voltage for SSR driving 0/4... 20mA (TLK43 only) 0/2... 10V (TLK43 only) Not available OUT 3 Relay Voltage for SSR driving Not available OUT 4 Relay Voltage for SSR driving Not available serial communication and digital INPUT RS485 RS485 and digital input (TLK43 only) Not available current transformer INPUT Available Not available PREPROGRAMMED SYSTEMS INPUTS TLK41 / tlk42 / tlk43 To compose the part number, pls. choose one of the option for each variable PLC AND OPERATOR PANELS Dual display: 4 red and green digit, h 7mm CONNECTIONS TIMERS COUNTERS POWER LIMITERS TLK43 INDICATORS TLK42 I/O MODULES Display TLK41 Single display: 4 red digit, h 12 mm SUPERVISION DISPLAY COMBUSTION CONTROL HOW TO ORDER features ACCESSORIES •UNIVERSAL INPUT •RS485 •UP TO 4 OUTPUTS •CT INPUT ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS tlk 41/42/43 25 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs INDUSTRIAL CONTROLLERS tlk72 24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz) 10 VA approx. 72 x 72 mm - depth 97 mm / 325 g approx. Flush in panel in 67 x 67 mm hole Screw terminal block 2 x 1 mm² IP 54, mounted on panel with gasket 0… +50°C (+32… +122°F) / -10... +60°C (+14… +140°F) 30… 95 RH% without condensation Directive CEE EMC 89/336 (EN 61326), Directive CEE BT 73/23 and 93/68 (EN 61010-1) DIN RAIL MOUNTING CONTROLLERS THERMOSTATS ANALOGUE CONTROLLERS SPECIAL CONTROLLERS AND “CUSTOM” C E I V R O R O R O - DIMENSIONS tlk72 S I - PAC SYSTEMS ON/OFF, Neutral Zone, PID AUTOTUNING, FAST TUNING, Selftuning Up to 4 pre-programmable Set Point RS485 with ModBus-RTU (JBUS) protocol 1200… 38400 baud, programmable L H PREPROGRAMMED SYSTEMS Auxiliary power supply FUNCTIONAL Control PID functions Multi Set Point Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1 : Relay SPDT (8 A-AC1, 3 A-AC3 / 250 V AC) or voltage to drive SSR 8Vdc/8 mA OUT 2 e OUT 3: Relay SPST-NO (8 A-AC1 3A-AC3/250 Vac) or voltage to drive SSR 8Vdc/8 mA 12 Vdc/20 mA max. TLK72 Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC (J,K,S,IRS)+PT100,mV TC (J,K,S,IRS)+PTC,NTC,mV 0/4… 20mA 0/1… 5V, 0/2… 10V OUT 1 Relay Voltage for SSR driving OUT 2 Relay Voltage for SSR driving Not available OUT 3 Relay Voltage for SSR driving Not available serial communication RS485 Not available digital INPUT Available Not available 8 72 9 AT ST SET Out1 Out2 - = PLC AND OPERATOR PANELS Up to 3 TLK72 To compose the part number, pls. choose one of the option for each variable 55 Accuracy OUTPUTS Thermocouples J (0... 1000 °C/ 32… 1832°F), K (0… 1370°C/32… 2498°F), S (0… 1760°C/32… 3200°F) and Infrared sensors J or K + Thermoresistances Pt 100 3 wires (-200... 850 °C/-328... 1562 °F) + Linear signals 0/10… 50mV, 0/12… 60mV Thermocouples J (0... 1000 °C/ 32… 1832°F), K (0… 1370°C/32… 2498°F), S (0… 1760°C/32… 3200°F) and Infrared sensors J or K + Thermistors PTC KTY 81-121 (990Ω at 25°C) (-55... 150 °C/-67... 302 °F) and Thermistors NTC 103AT-2 (10 kΩ at 25°C) (-50... 110 °C/-58... 230 °F) + Linear signals 0/10… 50mV, 0/12… 60mV Linear signals 0/4… 20mA Linear signals 0/1… 5V, 0/2… 10V ±0.5 % fs (tc S: ± 1% fs) CONNECTIONS 65.5 4 different configurations TLK72 4 red digit, h 12 mm + 3 LED Bargraph 72 DISPLAY Single INPUTS + 88 ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm TIMERS COUNTERS POWER LIMITERS HOW TO ORDER FEATURES ADVANCED PROGRAMMER CONTROLLERS •ON/OFF AND PID CONTROLLER •rs485 •UP TO 3 RELAY OUTPUTS 26 27 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs INDUSTRIAL CONTROLLERS tlk96 24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz) 10 VA approx. 96 x 96 mm (1/4 DIN) - depth 73 mm / 250 g approx. Flush in panel in 90 x 90 mm hole Screw terminal block 2 x 1 mm² IP 54, mounted on panel with gasket 0… 50°C (32… 122°F) / -10 ... 60 °C (14… 140°F) 30… 95 RH% without condensation Directive CEE EMC 89/336 (EN 61326), Directive CEE BT 73/23 and 93/68 (EN 61010-1) DIN RAIL MOUNTING CONTROLLERS THERMOSTATS ANALOGUE CONTROLLERS L H SPECIAL CONTROLLERS AND “CUSTOM” C E I V R O - PAC SYSTEMS R O DIMENSIONS PREPROGRAMMED SYSTEMS ON/OFF, Neutral Zone, PID AUTOTUNING ModBus TLK96 Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC (J,K,S,IRS)+PT100,mV TC (J,K,S,IRS)+PTC,NTC,mV 0/4… 20mA 0/1… 5V, 0/2… 10V OUT 1 Relay Voltage for SSR driving OUT 2 Relay Voltage for SSR driving Not available tlk96 9 96 60 12 TLK 96 PLC AND OPERATOR PANELS OUT 1 and OUT 2: Relay SPDT (8 A-AC1, 3 A-AC3 / 250 V AC) or voltage to drive SSR 8Vdc/8 mA 12 Vdc/20 mA max. tlk96 To compose the part number, pls. choose one of the option for each variable AT CNT OUT1 SET OUT2 55 Accuracy OUTPUTS Up to 2 Auxiliary power supply FUNCTIONAL Control PID functions Serial communication GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity Thermocouples J (0... 1000 °C/ 32… 1832°F), K (0… 1370°C/32… 2498°F), S (0… 1760°C/32… 3200°F) and Infrared sensors J or K + Thermoresistances Pt 100 3 wires (-200... 850 °C/-328... 1562 °F) + Linear signals 0/10… 50mV, 0/12… 60mV Thermocouples J (0... 1000 °C/ 32… 1832°F), K (0… 1370°C/32… 2498°F), S (0… 1760°C/32… 3200°F) and Infrared sensors J or K + Thermistors PTC KTY 81-121 (990Ω at 25°C) (-55... 150 °C/-67... 302 °F) and Thermistors NTC 103AT-2 (10 kΩ at 25°C) (-50... 110 °C/-58... 230 °F) + Linear signals 0/10… 50mV, 0/12… 60mV Linear signals 0/4… 20mA Linear signals 0/1… 5V, 0/2… 10V ±0.5 % fs (tc S: ± 1% fs) CONNECTIONS 88 4 different configurations TLK96 4 red digit, h 14 mm 96 DISPLAY Single INPUTS ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm TIMERS COUNTERS POWER LIMITERS HOW TO ORDER FEATURES ADVANCED PROGRAMMER CONTROLLERS •ON/OFF AND PID CONTROLLER •UP TO 2 RELAY OUTPUTS 28 29 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs Up to 4 FUNCTIONAL Control PID functions Multi Set Point Servomotor control Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity ON/OFF, PID single and double action, PID for servomotor control AUTOTUNING, FAST TUNING, Selftuning Up to 4 pre-programmable Set Point 3 points On analogue output RS485 with ModBus-RTU (JBUS) protocol 1200… 38400 baud, programmable 24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz) 10 VA approx. 48 x 96 mm (1/8 DIN) - depth 98 mm / 260 g approx. Flush in panel in 45 x 92 mm hole Screw terminal block 2 x 1 mm² IP 54, mounted on panel with gasket 0… 50°C (32… 122°F) / -10 ... 60 °C (14… 140°F) 30… 95 RH% without condensation Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1) R O - R O - tc S S H T - tc E tc L tc N tc R tc T Pt100 (IEC) 97.5 Out4 Out5 PTC (KTY81-121) NTC (103-AT2) Pt1000 (IEC) without DP -160 ... 1000 °C - 256 ... 1832 °F -100 ... 1370 °C - 148 ... 2498 °F 0 ... 1760 °C 32 ... 3200 °F 72 ... 1820 °C 162 ... 3308 °F -150 ... 750 °C -252 ... 1382 °F -150 ... 900 °C -252 ... 1652 °F -250 ... 1300 °C -418 ... 2372 °F -50 ... 1760 °C -58 ... 3200 °F -250 ... 400 °C -418 ... 752 °F 0 ... 2320 °C 32 ... 4208 °F -46 ... 785 °C -50 ... 1445 °F -200 ... 850 °C -50 ... 1445 °F -55 ... 150 °C -67 ... 302 °F -50 ... 110 °C -58 ... 230 °F -200 ... 500 °C -328 ... 932 °F DIN RAIL MOUNTING CONTROLLERS with DP -160.0 ... 999.9 °C -199.9 ... 999.9 °F -100.0 ... 999.9 °C -148.0 ... 999.9 °F 0.0 ... 999.9 °C 32.0 ... 999.9 °F 72.0 ... 999.9 °C 162.0 ... 999.9 °F -150.0 ... 750.0 °C -199.9 ... 999.9 °F -150.0 ... 900.0 °C -199.9 ... 999.9 °F -199.9 ... 999.9 °C -199.9 ... 999.9 °F -50.0 ... 999.9 °C -58.0 ... 999.9 °F -199.9 ... 400.0 °C -199.9 ... 752.0 °F 0.0 ... 999.9 °C 32.0 ... 999.9 °F -46.0 ... 785.0 °C -50.8 ... 999.9 °F -199.9 ... 850.0 °C -199.9 ... 999.9 °F -55.0 ... 150.0 °C -67.0 ...302.0 °F -50.0 ... 110.0 °C -58.0 ... 230.0 °F -199.9 ... 500.0 °C -199.9 ... 932.0 °F COMBUSTION CONTROL SET 89.5 TUN 96 tc B Infrared sensors PV TLK 94 The dimensions are expressed in mm 30 tc K tc C 10 Out6 tlk94 temperature Ranges INPUT tc J tlk94 SV TEMPERATURE RANGES R O - DIMENSIONS Out1 Out2 Out3 THERMOSTATS ANALOGUE CONTROLLERS R O I V - Note : When selected OUT 3, OUT 4 and OUT 5 must be identical. (ALL Relay or ALL voltage for SSR driving). 48 SPECIAL CONTROLLERS AND “CUSTOM” R O I V PAC SYSTEMS Up to 6 OUT 1 : Relay SPST-NO (6 A-AC1, 3 A-AC3 / 250 V AC) or 12Vdc/20 mA to drive SSR or 0/4… 20 mA or 0/2… 10 V OUT 2: Relay SPST-NO (4 A-AC1, 2 A-AC3 / 250 V AC) or 12Vdc/20 mA to drive SSR or 0/4… 20 mA or 0/2… 10 V OUT 3, OUT 4, OUT 5 : Relay SPST-NO (4 A-AC1, 2 A-AC3 / 250 V AC) or 12Vdc/20 mA to drive SSR OUT6: 12Vdc/20 mA to drive SSR 12 Vdc/20 mA max. L H PREPROGRAMMED SYSTEMS Accuracy Current transformer (CT) input Digital inputs OUTPUTS TLK94 Power supply 24 Vac/Vdc 100... 240 Vac/Vdc OUT 1 Relay SPDT 6 A-AC1 Voltage for SSR driving 0/4… 20 mA 0/2… 10 V OUT 2 Relay SPST-NO 4 A-AC1 Voltage for SSR driving 0/4… 20 mA 0/2… 10 V Not available OUT 3 Relay SPST-NO 4 A-AC1 Voltage for SSR driving Not available OUT 4 Relay SPST-NO 4 A-AC1 Voltage for SSR driving Not available OUT 5 Relay SPST-NO 4 A-AC1 Voltage for SSR driving Not available serial communication and digital INPUT RS485 CT input RS485 and CT input Not available PLC AND OPERATOR PANELS Universal Thermocouples J, K, S, B, C, E, L, N, R, T and Infrared sensors J or K + Thermoresistances Pt 100 and Pt1000 3 wires + Linear signals 0/10… 50mV, 0/4… 20mA, 0/12… 60mV, 0/1… 5V, 0/2… 10V (see table next page for temperature ranges) ± 0.2 % fs + 1 digit; PTC/NTC: ± 0.5 % fs + 1 digit CT 50 mA max. optoisolated 2 for free voltage contacts tlk94 To compose the part number, pls. choose one of the option for each variable TIMERS COUNTERS POWER LIMITERS INPUTS CONNECTIONS INDICATORS Dual display TLK94 Main display: 4 red digit, h 10 mm Secondary display: 4 green digit, h 7.5 mm I/O MODULES DISPLAY SUPERVISION HOW TO ORDER FEATURES ACCESSORIES •UNIVERSAL INPUT •RS485 •UP TO 5 OUTPUTS •servomotor control ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS tlk94 31 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs INDUSTRIAL CONTROLLERS c1 Auxiliary power supply FUNCTIONAL Control PID functions Signal retransmission Serial communication (as alternative to retransmission output) Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity ON/OFF or PID single action PID control with cycle time and overshoot control, 2 Autotuning algorithms Measuring retransmission Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires 1200... 9600 baud, programmable 100… 240 Vac/Vdc (-15...+10%), 24Vac(-25...+12%) and 24Vdc (-15...+25%) (50/60Hz) 3 VA max. 48 x 24 - depth 120 mm / 100 g approx. Flush in panel in 45 x 22.2 mm hole Screw terminal block M3 for cables with section 1 mm² (18AWG) IP65 0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F) 5… 95% RH% without condensation EN 61000-6-3:2001, EN 61000-6-4:2001, EN 61000-6-2:2001 Not available RS485 special functions Limit switch version Not available INSTRUCTION MANUAL Italian/English Not available FRONT FRAME COLOUR Dark grey Dark grey + shunt 0.1% special execution Not available On DIN rail On DIN rail no display Tropicalized DIN RAIL MOUNTING CONTROLLERS CODE 3 5 0 3 6 Options Not available Transmitter Power supply Transmitter Power supply + retransmission Not available Transmitter Power supply THERMOSTATS ANALOGUE CONTROLLERS C1 Power supply 100… 240 Vac/Vdc 24 Vac/Vdc OUTPUTS Relay Triac Voltage for SSR driving serial communication Pt100 00 Termocoppia 06 mV Shunt esterno 2.5Ω mA 07 50 56 DIMENSIONS c1 9 0 0 9 0 2 0 1 2 3 48 SPECIAL CONTROLLERS AND “CUSTOM” Up to 3 OUT 1: Relay SPST-NO 2A/250Vac-AC1 / Triac 1A/250Vac-AC1 OUT 2: 5Vdc 30mA max., ± 10% (not isolated) to drive SSR OUT 3 (opt.): Measuring retransmission, current: 0/4… 20mA 750Ω/15V max. (as alternative to RS485) +18Vdc ±20%, 30mA max. for external transmitter c1 To compose the part number, pls. choose one of the option for each variable PAC SYSTEMS Accuracy OUTPUTS Thermocouples: L ,J (0… 600°C/32… 1112°F), T (-200… 400/-328… 752°F), K (0…1200°C/32… 2192°F), S (0… 1600°C/32… 2912°F) + Thermoresistances PT100 (-200… 600°C/-328… 1112°F or -99.9… 300.0°C/-99.9… 572.9°F) connection with 2 or 3 wires + Linear signals: 0/10... 50 mV; 0/4…20 mA + Infrared sensors or special ranges (custom) 0.25% ±1 digit (for thermoelements); 0.1% ±1 digit (for mA and mV) CONNECTIONS PREPROGRAMMED SYSTEMS Universal C1 4 green digit, h 9 mm + 3 LEDs 120 25 ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm PLC AND OPERATOR PANELS DISPLAY Single INPUTS TIMERS COUNTERS POWER LIMITERS HOW TO ORDER FEATURES ADVANCED PROGRAMMER CONTROLLERS •controller / Indicator •with 1 or 2 alarms 32 33 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs INDUSTRIAL CONTROLLERS m1 ON/OFF or PID single action PID control with cycle time and overshoot control, 2 Autotuning algorithms Measuring or Set Point retransmission Not available RS485 Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires 1200... 9600 baud, programmable 100… 240 Vac/Vdc (-15...+10%), 24Vac(-25...+12%) and 24Vdc (-15...+25%) (50/60Hz) 3.5 VA max. 48 x 48 - depth 120 mm / 130 g approx. Flush in panel in 45 x 45 mm hole Screw terminal block M3 for cables with section 1 mm² (18AWG) IP65 0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F) 5… 95% RH% without condensation EN 61000-6-3:2001, EN 61000-6-4:2001, EN 61000-6-2:2001 SPECIAL FUNCTIONS Limit switch version Not available INSTRUCTION MANUAL Italian/English Not available FRONT FRAME COLOUR Dark grey Dark grey + shunt 0.1% SPECIAL EXECUTION Not available On DIN rail On DIN rail no display Tropicalized DIN RAIL MOUNTING CONTROLLERS CODE THERMOSTATS ANALOGUE CONTROLLERS 3 5 0 3 6 7 OPTIONS Not available Transmitter Power supply Transmitter Power supply + retransmission Not available Transmitter Power supply mV Termocoppia Shunt esterno 2.5Ω 00 06 Pt100 mA 07 50 56 DIMENSIONS m1 9 0 0 9 0 2 0 1 2 3 48 120 48 10 max. The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS Auxiliary power supply FUNCTIONAL Control PID functions Signal retransmission Serial communication (as alternative to retransmission output) Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1: Relay SPST-NO 2A/250Vac-AC1 / Triac 1A/250Vac-AC1 OUT 2 + OUT 3: 5Vdc 30mA max., ± 10% (not isolated) to drive SSR / Relay SPST-NO (2A/250Vac-AC1) OUT 4 (opt.): Measuring or Set Point retransmission, current: 0/4… 20mA 750Ω/15V max. (as alternative to RS485) +18Vdc ±20%, 30mA max. for external transmitter M1 Power supply 100… 240 Vac/Vdc 24 Vac/Vdc OUTPUTS Relay/Relay Triac/Relay Relay/Voltage for SSR driving Relay/triac serial communication SPECIAL CONTROLLERS AND “CUSTOM” Up to 4 m1 To compose the part number, pls. choose one of the option for each variable PAC SYSTEMS Accuracy OUTPUTS Thermocouples: L ,J (0… 600°C/32… 1112°F), T (-200… 400/-328… 752°F), K (0…1200°C/32… 2192°F), S (0… 1600°C/32… 2912°F) + Thermoresistances PT100 (-200… 600°C/-328… 1112°F or -99.9… 300.0°C/-99.9… 572.9°F) connection with 2 or 3 wires + Linear signals: 0/10... 50 mV; 0/4…20 mA + Infrared sensors or special ranges (custom) 0.25% ±1 digit (for thermoelements); 0.1% ±1 digit (for mA and mV) CONNECTIONS PREPROGRAMMED SYSTEMS Universal M1 4 green digit, h 10 mm + 6 LEDs PLC AND OPERATOR PANELS DISPLAY Single INPUTS TIMERS COUNTERS POWER LIMITERS HOW TO ORDER FEATURES ADVANCED PROGRAMMER CONTROLLERS •controller / Indicator / transmitter •with 1 or 2 alarms 34 35 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs INDUSTRIAL CONTROLLERS m2 Up to 3 Auxiliary power supply FUNCTIONAL Control PID functions Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1: Relay SPST-NO 2A/250Vac-AC1 OUT 2: 5Vdc, ±10%, 30mA max. (not isolated) to drive SSR / Relay SPST-NO, 2A/250Vac-AC1 OUT 3: Relay SPST-NO 2A/250Vac-AC1 +18Vdc ±20%, 30mA max. for external transmitter ON/OFF, PID a singola/doppia azione Dead band, relative cooling gain, cooling sampling time, overshoot control, higher limit Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires 1200... 9600 baud, programmable 100… 240Vac (-15...+10%) o 24Vdc (-25...+12%) e 24Vdc (-15...+25%) (50/60Hz) 2.6 VA max. 48 x 48 - depth 120 mm / 130 g Flush in panel in 45 x 45 hole Screw terminal block M3 for cables with section 1 mm² (18AWG) IP65 0… 50°C (32… 122°F) / -20…+70°C (-4… 158°F) 5… 95% RH without condensation EN 61010-1 Not available INPUT digitale DIN RAIL MOUNTING CONTROLLERS CODE 9 Ingresso digitale 10 3 5 11 THERMOSTATS ANALOGUE CONTROLLERS Accuracy Auxiliary input Digital inputs OUTPUTS M2 Power supply 100… 240 Vac/Vdc 24 Vac/Vdc OUT 2 Relay/Voltage for SSR driving Voltage for SSR driving INPUT digitale 1 6 OPTIONS Not available Current Transformer input (CT) Not available Current Transformer input (CT) SPECIAL FUNCTIONS Not available SP modification from digital input Average Safety Output SP modification from digital input + Average Safety Output INSTRUCTION MANUAL Italian/English Not available FRONT FRAME COLOUR Dark grey Dark grey + shunt 0.1% SPECIAL EXECUTION Not available On DIN rail On DIN rail no display Tropicalized mV 00 Shunt esterno 2.5Ω 03 90 0 9 Trasformatore amperometrico Pt100 mA 93 0 6 7 8 Termocoppia DIMENSIONS m2 48 120 0 2 0 1 2 3 SPECIAL CONTROLLERS AND “CUSTOM” Universal Thermocouples: L/J (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F), K (0…+1200°C / 32…+2192°F), S (0... +1600°C / 32...2912°F) Thermoresistances: PT100 connection with 2 or 3 wires (-200... +600°C / -328... +1112°F) Linear signals: 0/10... 50 mV; 0/4…20 mA Infrared sensors or special ranges (custom) 0.25% ±1 digit (for thermoelements); 0.1% ±1 digit (for mA and mV) Current Transformer for Heater Break function 1 digital input for free voltage contacts m2 To compose the part number, pls. choose one of the option for each variable PAC SYSTEMS INPUTS CONNECTIONS PREPROGRAMMED SYSTEMS Dual M2 Main display: 4 green digit, h 10 mm Secondary display: 4 green digit, h 8 mm + 6 LEDs PLC AND OPERATOR PANELS DISPLAY 48 10 max. ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm TIMERS COUNTERS POWER LIMITERS HOW TO ORDER FEATURES ADVANCED PROGRAMMER CONTROLLERS •temperaturE CONTROLLER FOR HOT RUNNERS 36 37 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs INDUSTRIAL CONTROLLERS m3 / m4 Up to 4 Auxiliary power supply Outputs configurations FUNCTIONAL Control Alarms PID functions Special functions Signal retransmission Serial communication (opt.) Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1: Relay SPST-NO 2A/250Vac-AC1 / Triac OUT 2: 5Vdc, ±10%, 30mA max.(not isolated) to drive SSR / Relay SPST-NO, 2A/250Vac-AC1 OUT 3: Relay SPST-NO 2A/250Vac-AC1 / Triac OUT 4 (opt.): Measuring or Set Point retransmission, OUT 4: (Opt.) control output, current: 0/4… 20mA 750Ω/15V max. (as alternative to RS485) current: 0/4… 20mA 750Ω/15V max. +18Vdc ±20%, 30mA max. for external transmitter 1 loop PID or ON/OFF double action with 1 or 2 alarms ON/OFF or PID single/double action 2 alarms programmable as high/low or band alarm Hysteresis 0.1… 10.0% e.s. Dead band, relative cooling gain, cooling sampling time, overshoot control, higher limit Sensor Break, Heater Break, Latching/Blocking and loop break Measuring or Set Point retransmission Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires 1200... 9600 baud, programmable 100… 240 Vac (-15...+10%) o 24Vac (-25...+12%) and 24Vdc (-15...+25%) (50/60Hz) 6 VA max. 48 x 48 - depth 120 mm / 130 g Flush in panel in 45 x 45 mm hole Screw terminal block M3 for cables with section 1 mm² (18AWG) IP65 0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F) 5… 95% RH without condensation EN 61010-1 DIN RAIL MOUNTING CONTROLLERS THERMOSTATS ANALOGUE CONTROLLERS External shunt 2.5Ω Thermo couple Current transformer Pt100 mA m4 00 03 06 07 mV 08 External shunt 2.5Ω 09 Thermo couple Current transformer Pt100 Logic input 50 mA 56 58 90 93 DIMENSIONS m3 / m4 97 99 0 2 9 0 9 0 2 0 1 2 3 (*) With code 07 and code 09, the analogue output can be used also as control output. 38 mV PAC SYSTEMS Auxiliary input (optional) OUTPUTS 0 1 2 4 5 7 8 PREPROGRAMMED SYSTEMS Digital inputs 3 5 PLC AND OPERATOR PANELS Accuracy CODE TIMERS COUNTERS POWER LIMITERS Universal Thermocouples: L/J (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F), K (0…+1200°C / 32…+2192°F), S (0... +1600°C / 32...2912°F) Thermoresistances: PT100 connection with 2 or 3 wires (-200... +600°C / -328... +1112°F) Linear signals: 0/10... 50 mV; 0/4…20 mA Infrared sensors or special ranges (custom) 0.25% ±1 digit (for thermoelements); 0.1% ±1 digit (for mA and mV) Auto/man switching, stand-by/Set Point -switching, keyboard lock, timer Current Transformer for Heater Break function M3 / M4 Power supply 100… 240 Vac/Vdc 24 Vac/Vdc OUT 1, 2 e 3 Relay/Relay/Voltage for SSR driving Relay/Relay/Voltage for SSR driving + Relay Relay/Relay/Voltage for SSR driving + triac Triac/Relay/Voltage for SSR driving + Relay Triac/Relay/Voltage for SSR driving + triac Relay + triac/Voltage for SSR driving + Relay (M3 only) Relay + Voltage for SSR driving (M3 only) Serial communication + OPTIONS digital INPUT Not available Current Transformer input (CT) Transmitter supply 18V Transmitter supply 18V Not available + Retransmission (*) + CT input Transmitter supply 18V+ CT input Transmitter supply 18V + CT input + Retransmission (*) Not available Transmitter supply 18V RS485 Transmitter supply 18V + CT input Not available CT input Analogue INPUT digitale (Solo M4) Control Output Analogue Control Output + CT input SPECIAL FUNCTIONS Not available Start-up + Timer Limit switch version INSTRUCTION MANUAL Italian/English Not available FRONT FRAME COLOUR Dark grey Dark grey + shunt 0,1% SPECIAL EXECUTION Not available On DIN rail Mounting B/DIN, No display Tropicalized 48 INDICATORS INPUTS m3 To compose the part number, pls. choose one of the option for each variable 120 I/O MODULES Main display: 4 green digit, h 10 mm Secondary display: 4 green digit, h 6.75 mm + 5 LEDs CONNECTIONS 48 10 max. SUPERVISION M4 The dimensions are expressed in mm COMBUSTION CONTROL Dual M3 ACCESSORIES DISPLAY SPECIAL CONTROLLERS AND “CUSTOM” HOW TO ORDER FEATURES ADVANCED PROGRAMMER CONTROLLERS •Regolatore caldo-freddo •Regolatore caldo-freddo con uscita continua 39 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs INDUSTRIAL CONTROLLERS x1 / x3 Up to 5 Analogue control output Auxiliary power supply FUNCTIONAL Control Alarms PID functions Double action (Heat-Cool) with overlap Servomotor control (without position potentiometer) Pre-programmed Set Point Special functions Tuning Auto/Man Station PID with overshoot control or ON/OFF single/double action with 1, 2 or 3 alarms PID with overshoot control or ON/OFF single/double action with 1, 2 or 3 alarms PID for Servomotor control Up to 3 Error dead band, overshoot control, manual reset, cycle time, Control output high limit, Soft-start output valve, output safety value Dead band, Relative cool gain, cycle time (time proportional output), Cool output high limit For X3 only: Cool output hysteresis -- Motor travel time, motor minimum step 1 program, 8 segments 1 initial and 1 end, -from 1 to 9999 cycles/continuous cycling Timer (1… 9999s/min), Stand-by Set Point, Start-up, Start-up Set Point One Shot Tuning Fuzzy Tuning One Shot Standard with Bumpless function, by keypad -digital input or serial communication Measuring or Set Point retransmission Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires 1200, 2400, 4800, 9600 bit/sec, 2 wires 100… 240Vac (-15… +10%) or 24Vac (-25… +12%) and 24Vdc (-15… +25%) / 50/60Hz 6VA max. 48 x 96 mm - depth 110 mm / 250 g approx. Flush in panel in 45 x 92 mm hole Screw terminal block M3 for cables with section 1 mm² (18AWG) IP65 0… 50°C (32… 122°F) / -20…+70°C (-4… 158°F) 5… 95% RH without condensation EN 61010-1 DIN RAIL MOUNTING CONTROLLERS THERMOSTATS ANALOGUE CONTROLLERS V Current Transformer mV 0 5 mA mA Thermocouple External shunt 2.5Ω Pt100 0 2 5 5 7 X3 TTL 0 2 3 NPN NO V Current Transformer 0 9 mV 0 2 Pt100 mA Thermocouple mA External shunt 2.5Ω 0 3 DIMENSIONS x1 / x3 48 110 96 10 max. The dimensions are expressed in mm ACCESSORIES Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1: Relay, NO, 2A/250Vac (4A/120Vac) or TRIAC 1A/250Vac OUT 2: Relay, NO, 2A/250Vac (4A/120Vac) or TRIAC 1A/250Vac OUT 3: Relay,SPDT, 2A/250Vac (4A/120Vac) OUT 4: Relay, SPDT, 2A/250Vac (4A/120Vac) or Logic not isolated: 0/5Vdc, ±10% 30mA max. OUT 5: Analogue for Measuring or Set Point retransmission, current: 0/4… 20mA max. 750Ω/10V max. Measuring or Set Point retransmission, current: 0/4… 20mA 750Ω/15V max. or voltage: 0… 1/5/10V 500Ω/20mA max. +18Vdc ±20%, 30mA max. for external transmitter (2, 3 or 4 wires) 1 5 9 SPECIAL CONTROLLERS AND “CUSTOM” Digital inputs OUTPUTS 3 5 PAC SYSTEMS Auxiliary input CODE PREPROGRAMMED SYSTEMS Accuracy X1 / X3 Power supply 100… 240 Vac/Vdc 24 Vac/Vdc OUT 1,out 2, out 3 and out 4 Relay-Relay-Relay-Voltage for SSR driving Triac-triac-Relay-Voltage for SSR driving Relay-Relay-Relay-Relay Serial communication Not available RS485 OPTIONS Not available Servomotor (X3 only) Retransmission + Remote Set Point (X1 only) Analogue Output + Remote Set Point (X3 only) Servomotor + Analogue Output + Remote Set Point (X3 only) SPECIAL FUNCTIONS Not available Start-up + Timer 1 Program 8 segments (X3 only) INSTRUCTION MANUAL Italian/English Not available FRONT FRAME COLOUR Dark grey Dark grey + shunt 0.1% SPECIAL EXECUTION Not available Tropicalized PLC AND OPERATOR PANELS Universal Thermocouples: L/J (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F), K (0…+1200°C / 32…+2192°F), S/R (0... +1600°C / 32...2912°F) Thermoresistances: PT100 connection with 2 or 3 wires (-200... +600°C / -328... +1112°F) Linear signals: 0/10... 50 mV; 0/4…20 mA Infrared sensors or special ranges (custom) 0.25% ±1 digit (for thermoelements); 0.1% ±1 digit (for mA and mV) Non isolated remote Set Point: current 0/4… 20mA or voltage 1… 5/ 0… 5/ 0… 10V Current Transformer for Heater Break function -3 X1 To compose the part number, pls. choose one of the option for each variable TIMERS COUNTERS POWER LIMITERS INPUTS CONNECTIONS INDICATORS X3 Main display: 4 green digit, h 10 mm Secondary display: 4 green digit, h 9 mm + 16 LEDs, I/O MODULES Dual X1 Main display: 4 green digit, h 10 mm Secondary display: 4 green digit, h 9 mm + 11 LEDs SUPERVISION DISPLAY COMBUSTION CONTROL HOW TO ORDER FEATURES ADVANCED PROGRAMMER CONTROLLERS •heat-cool temperature controllers •double action controller with analogue output 40 41 IND U S T R I A L aut o m ati o n | IND U S T R I A L c o ntr o ll e rs INDUSTRIAL CONTROLLERS q1 / q3 Up to 5 Auxiliary power supply FUNCTIONAL Control Alarms PID functions Double action (Heat-Cool) with overlap Servomotor control (without position potentiometer) Pre-programmed Set Point Special functions Tuning Auto/Man Station Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1: Relay, NO, 2A/250Vac (4A/120Vac) or TRIAC 1A/250Vac OUT 2: Relay, NO, 2A/250Vac (4A/120Vac) or TRIAC 1A/250Vac OUT 3: Relay,SPDT, 2A/250Vac (4A/120Vac) OUT 4: Logic not isolated: 0/5Vdc, ±10% 30mA max. for retransmission OUT 5: Analogue for Measuring or Set Point retransmission, current: 0/4… 20mA max. 750Ω/10V max. +18Vdc ±20%, 30mA max. for external transmitter (2, 3 or 4 wires) PID with overshoot control or ON/OFF single/double action with 1, 2 or 3 alarms PID with overshoot control or ON/OFF single/double action with 1, 2 or 3 alarms PID for Servomotor control Up to 3 Error dead band, overshoot control, manual reset, cycle time, Control output high limit, Soft-start output valve, output safety value Dead band, Relative cool gain, cycle time (time proportional output), Cool output high limit For Q3 only: Cool output hysteresis -- Motor travel time, motor minimum step 1 program, 8 segments 1 initial and 1 end, from 1 to 9999 cycles/continuous cycling Timer (1… 9999s/min), Stand-by Set Point, Start-up, Start-up Set Point One Shot Tuning Fuzzy Tuning One Shot Standard with Bumpless function, by keypad -digital input or serial communication Measuring or Set Point retransmission Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires 1200, 2400, 4800, 9600 bit/sec, 2 wires -- 100… 240Vac (-15… +10%) or 24Vac (-25… +12%) and 24Vdc (-15… +25%) / 50/60Hz 6 VA max. 96 x 96 mm - depth 110 mm / 470 g approx. Flush in panel in 92 x 92 mm hole Screw terminal block M3 for cables with section 1 mm² (18AWG) IP65 0… 50°C (32… 122°F) /-20…+70°C (-4… 158°F) 5… 95% RH without condensation EN 61010-1 DIN RAIL MOUNTING CONTROLLERS V Current Transformer mV 0 5 mA mA Thermocouple External shunt 2.5Ω Pt100 0 2 5 5 7 q3 TTL 0 2 3 NPN NO V Current Transformer 0 9 mV 0 2 Pt100 0 3 THERMOSTATS ANALOGUE CONTROLLERS 1 5 9 SPECIAL CONTROLLERS AND “CUSTOM” Digital inputs OUTPUTS 3 5 PAC SYSTEMS Auxiliary input CODE PREPROGRAMMED SYSTEMS Accuracy Q1 / Q3 Power supply 100… 240 Vac/Vdc 24 Vac/Vdc OUT 1,out 2, out 3 and out 4 Relay-Relay-Relay-Voltage for SSR driving Triac-triac-Relay-Voltage for SSR driving Relay-Relay-Relay-Relay Serial communication Not available RS485 OPTIONS Not available Servomotor (Q3 only) Retransmission + Remote Set Point (Q1 only) Analogue Output + Remote Set Point (Q3 only) Servomotor + Analogue Output + Remote Set Point (Q3 only) SPECIAL FUNCTIONS Not available Start-up + Timer 1 Program 8 segments (Q3 only) INSTRUCTION MANUAL Italian/English Not available FRONT FRAME COLOUR Dark grey Dark grey + shunt 0.1% SPECIAL EXECUTION Not available Tropicalized mA mA Thermocouple PLC AND OPERATOR PANELS Universal Thermocouples: L/J (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F), K (0…+1200°C / 32…+2192°F), S (0... +1600°C / 32...2912°F) Thermoresistances: PT100 connection with 2 or 3 wires (-200... +600°C / -328... +1112°F) Linear signals: 0/10... 50 mV; 0/4…20 mA Infrared sensors or special ranges (custom) 0.25% ±1 digit (for thermoelements); 0.1% ±1 digit (for mA and mV) Non isolated remote Set Point: current 0/4… 20mA or voltage 1… 5/ 0… 5/ 0… 10V Current Transformer for Heater Break function -3 q1 To compose the part number, pls. choose one of the option for each variable External shunt 2.5Ω TIMERS COUNTERS POWER LIMITERS INPUTS CONNECTIONS DIMENSIONS q1 / q3 96 INDICATORS Q3 Main display: 4 green digit, h 15 mm Secondary display: 4 green digit, h 12 mm + 16 LEDs 110 I/O MODULES Dual HOW TO ORDER Q1 Main display: 4 green digit, h 15 mm Secondary display: 4 green digit, h 12 mm + 11 LEDs 96 10 max. SUPERVISION FEATURES DISPLAY ADVANCED PROGRAMMER CONTROLLERS •heat-cool temperature controllers •double action controller with analogue output ACCESSORIES COMBUSTION CONTROL The dimensions are expressed in mm 42 43 ADVANCED PROGRAMMER CONTROLLERS The most complete range you may wish! Single and muliloop controllers and advanced programmers, multifunction and with incorporated and independent timer, in all sizes. New KUBE line: more and more in less space! Pocket size, energy saving functions and advanced features. 44 45 ADVANCED programmER CONTROLLERS Control K49 · · K85 K30 M5 X5 Q5 · · · · · · · · · · · · · · · · · · · · · · 2 · 3 · · · 3 · · 4 2 · 4 2 · · · · · · · · · · · · · · · · · · · · · · · · · · Universal J-K-S-R-T + IR + PTC-NTC J-K-S-R-T + IR + Pt100 ∆T PT100 Digital Frequency Potentiometer For CT 12 Vac/Vdc 24 Vac/Vdc 100… 240 Vac ON/OFF and PID Servomotor control · 2 · 2 · 2 4 1 · 4 1 · 4 1 · · · · · · · · · · · · · · · · 2 2 · · · · · · · · · · 2 2 2 · · 4 4 2 2 3 3 3 5 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 3 1 · · · · · · · · · THERMOSTATS ANALOGUE CONTROLLERS K48 SPECIAL CONTROLLERS AND “CUSTOM” K39 · PAC SYSTEMS K38 · ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES RS485 ModBus Slave RS485 ModBus Master Profibus DP Mathematical package Timer on board Programmer CE certification UL approval ENEC approval K32 · · · Relay or voltage for SSR drive outputs Analogue current or voltage outputs Measuring or Set Point retransmission Power supply K31 · PREPROGRAMMED SYSTEMS Input KR3 · PLC AND OPERATOR PANELS 3 dynamic colour dual LED display 4 digit Single display 4 digit Dual display 4 digit Triple display "Sensitive Touch" keyboard KX3 TIMERS COUNTERS POWER LIMITERS Dimensions (mm) KM3 78x35 48x48 48x96 70 x 84 4 DIN Modules 96x96 INDICATORS FEATURES DIN RAIL MOUNTING CONTROLLERS ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S 46 47 Up to 4 FUNCTIONAL Control 24 Vac/Vdc ± 10%, 100… 240 Vac/Vdc -15%/+ 10% (50/60 Hz) 7 VA max 48 x 48 mm (1/16 DIN) - depth 63 mm / 125 g Flush in panel in 45 x 45 mm hole 16 screw terminals 2.5 mm² (AWG22…. AWG14) fix, plug-in or clamp type IP 65, mounted on panel with gasket 0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F) 20… 95 RH% without condensation EN 61010-1, EN 61326 mV, V mA 3 wires DIN RAIL MOUNTING CONTROLLERS TERMINALS R O R O - L Pin connector: 1.4 mm - 0.055 in. max. Stripped wire L 5.5 mm - 0.21 in. q PV Note: Terminal 4 can be programmed as: - Digital Input (DI2) connecting a free of voltage contact between terminals 4 and 16 - 0... 12 V SSR Drive Output (OP4) connecting the load between terminals 4 and 16 - 12 Vdc (20 mA) transmitter power supply connecting the transmitter between terminals 4 and 1 Transducer Passive 4... 20 mA Pt1000/NTC/PTC Pt100 DIMENSIONS km3 48 11 14 48 D S E N M - THERMOSTATS ANALOGUE CONTROLLERS Line 100... 240 VAC/ 20... 30 VDC Neutral Thermocouple SPECIAL CONTROLLERS AND “CUSTOM” Transducer R O I Close 12 VDC (note) PV 12 VDC (note) C E Open OP3 * Terminals 18 10 15 The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL Alarms Set Point Signal retransmission Serial communication Baud rate Working hours counters Wattmeter function EVOogreen Programmer (optional) Timer (optional) GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity PID single or double action, ON/OFF, ON/OFF with Neutral Zone Autotuning and Selftuning algorithms, Overshoot control 3 alarms programmable as absolute, deviation, band 4 programmable Set Points Measuring or Set Point retransmission TTL (standard) + RS485 (optional), ModBus RTU protocol 1200… 38400 baud A cumulative non-erasable counter and a second one resettable with alarm Instantaneous power, time consumption Stand-by mode of display, selectable Up to 8 segments with guaranteed soak Independent with 5 function modes ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS OUT 1: Relay SPST-NO 4A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10% or analogue galvanically isolated 0/4... 20 mA, 0/2... 10V (optional) OUT 2: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10% OUT 3: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 110.5V min. @ 15mA ±10% OUT 4 programmable: voltage output to drive SSR 13V max. @ 1mA, 10.5V min. @ 22mA ±10% or transmitter supply or 2nd digital input OP4 (note) Analogue input 2 wires L H OP2 * DI2 (note) PAC SYSTEMS OUTPUTS T P DI1 OP1 RS485 PREPROGRAMMED SYSTEMS Digital inputs CODE PLC AND OPERATOR PANELS Accuracy KM3 Version Controller Controller + Timer Controller + Timer + Programmer Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC, RTD, mA, V, mV/digital input 1 TC, NTC, PTC, mA, V, mV/digital input 1 OUT 1 Relay SPST 4A Vdc for SSR driving 0/4… 20 mA, 0/2... 10V galvanically isolated (control and retransmission) OUT 2 Relay SPST 2A Vdc for SSR driving Not available OUT 3 Relay SPST 2A Vdc for SSR driving Not available OUT 4 Digital input 2 or digital output or transmitter supply RS485 Available Not available connection Plug-in screw type Plug-in screw type, fix part only Clamp type Fix screw type (standard) TIMERS COUNTERS POWER LIMITERS Universal Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F), S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F) Infrared sensors: J or K Thermoresistances: 3 wires Pt 100 and 2 wires Pt 1000 (-200... 850°C/-328... 1562°F) Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F), S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F) Infrared sensors: J or K Thermistors: PTC KTY81-121 (-55... +150°C/-67... 302°F), NTC 103 AT2 (-50... +110°C/-58... 230°F) Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V ± 0.5% span ±1 digit, (±1% span ±1 digit for T/c S type) 1 or 2 according to instrument’s part number (the 2nd digital input is alternative to OUT 4) km3 To compose the part number, pls. choose one of the option for each variable INDICATORS INPUTS CONNECTIONS I/O MODULES Dual LED KM3 Main display: 4 digit h 15.5 mm. 3 colours: red, green and amber Secondary display: 4 green digit, h 7 mm 14 DISPLAY SUPERVISION HOW TO ORDER FEATURES 45 •3 dynamic colour led display •analogUE CONTROL OUTPUT •8 segmentS PROGRAMMER / Timer •WORKING hours counter 48 km3 IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S 48 49 Up to 4 OUT 1: Relay SPST-NO 4A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10% or analogue galvanically isolated 0/4... 20 mA, 0/2... 10V (optional) OUT 2: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10% OUT 3: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 110.5V min. @ 15mA ±10% OUT 4 programmable: voltage output to drive SSR 13V max. @ 1mA, 10.5V min. @ 22mA ±10% or transmitter supply or 2nd digital input FUNCTIONAL Control 24 Vac/Vdc ± 10%, 100… 240 Vac/Vdc -15%/+ 10% (50/60 Hz) 7 VA max 48 x 96 mm (1/8 DIN) - depth 76 mm / 160 g Flush in panel in 45 x 93 mm hole 16 screw terminals 2.5 mm² (AWG22…. AWG14) fix, plug-in or clamp type IP 65 mounted on panel with gasket 0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F) 20… 95 RH% without condensation EN 61010-1, EN 61326 DIN RAIL MOUNTING CONTROLLERS Stripped wire L 5.5 mm - 0.21 in. NO L H OP3 * C THERMOSTATS ANALOGUE CONTROLLERS Close Note: Terminal 4 can be programmed as: - Digital Input (DI2) connecting a free of voltage contact between terminals 4 and 5 - 0... 12 V SSR Drive Output (OP4) connecting the load between terminals 4 and 5 - 12 Vdc (20 mA) transmitter power supply connecting the transmitter between terminals 4 and 1 NO Open OP2 * C NA RS485 Analogue input OP1 C KX3 only SPECIAL CONTROLLERS AND “CUSTOM” q T P 100... 240 Vac/ Fase 20... 30 Vdc Neutral L Pin connector: 1.4 mm - 0.055 in. max. DI1 Pt1000/NTC/PTC C E 12 Vdc (note) OP4 (note) 2 wires PV Transducer R O R O - DI2 (note) 3 wires PV I Pt100 Passive 4... 20 mA Transducer 12 Vdc (note) mV, V mA Thermocouple DIMENSIONS kx3 48 11 62 14 18 R O D S E N M - The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL Alarms Set Point Signal retransmission Serial communication Baud rate Working hours counters Wattmeter function EVOogreen Programmer (optional) Timer (optional) GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity PID single or double action, ON/OFF, ON/OFF with Neutral Zone Autotuning and Selftuning algorithms, Overshoot control 3 alarms programmable as absolute, deviation, band 4 programmable Set Points Measuring or Set Point retransmission TTL (standard) + RS485 (optional), ModBus RTU protocol 1200… 38400 baud A cumulative non-erasable counter and a second one resettable with alarm Instantaneous power, time consumption Stand-by mode of display, selectable Up to 8 segments with guaranteed soak Independent with 5 function modes ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS OUTPUTS TERMINALS PAC SYSTEMS Digital inputs CODE PREPROGRAMMED SYSTEMS Accuracy KX3 VERSION Controller Controller + Timer Controller + Timer + Programmer Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC, RTD, mA, V, mV/digital input 1 TC, NTC, PTC, mA, V, mV/digital input 1 OUT 1 Relay SPST 4A Vdc for SSR driving 0/4… 20 mA, 0/2... 10V galvanically isolated (control and retransmission) OUT 2 Relay SPST 2A Vdc for SSR driving Not available OUT 3 Relay SPST 2A Vdc for SSR driving Not available OUT 4 Digital input 2 or digital output or transmitter supply RS485 Available Not available connection Plug-in screw type Plug-in screw type, fix part only Clamp type Fix screw type (standard) PLC AND OPERATOR PANELS Universal Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F), S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F) Infrared sensors: J or K Thermoresistances: 3 wires Pt 100 and 2 wires Pt 1000 (-200... 850°C/-328... 1562°F) Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F), S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F) Infrared sensors: J or K Thermistors: PTC KTY81-121 (-55... +150°C/-67... 302°F), NTC 103 AT2 (-50... +110°C/-58... 230°F) Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V ± 0.5% span ±1 digit, (±1% span ±1 digit for T/c S type) 1 or 2 according to instrument’s part number (the 2nd digital input is alternative to OUT 4) kx3 To compose the part number, pls. choose one of the option for each variable TIMERS COUNTERS POWER LIMITERS INPUTS CONNECTIONS INDICATORS Dual LED KX3 Main display: 4 digit h 15.5 mm. 3 colours: red, green and amber Secondary display: 4 green digit, h 10 mm 20 segments Bargraph I/O MODULES DISPLAY SUPERVISION HOW TO ORDER FEATURES 89 •3 dynamic colour led display •analogUE CONTROL OUTPUT •8 segmentS PROGRAMMER / Timer •WORKING hours counter 96 KX3 IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S 50 51 Up to 4 OUT 1: Relay SPDT 4A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10% or analogue galvanically isolated 0/4... 20 mA, 0/2... 10V (optional) OUT 2: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 10.5V min. @ 15mA ±10% OUT 3: Relay SPST-NO 2A/240 Vac or voltage to drive SSR 13V max. @ 1mA, 110.5V min. @ 15mA ±10% OUT 4 programmable: voltage output to drive SSR 13V max. @ 1mA, 10.5V min. @ 22mA ±10% or transmitter supply or 2nd digital input FUNCTIONAL Control 24 Vac/Vdc ± 10%, 100… 240 Vac/Vdc -15%/+ 10% (50/60 Hz) 7 VA max 48 x 48 mm (1/16 DIN) - depth 63 mm / 125 g Flush in panel in 45 x 45 mm hole 16 screw terminals 2.5 mm² (AWG22…. AWG14) fix, plug-in or clamp type IP 65, mounted on panel with gasket 0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F) 20… 95 RH% without condensation EN 61010-1, EN 61326 DIN RAIL MOUNTING CONTROLLERS Passive 4... 20 mA PV 2Vdc (note) mV, V L H RS485 Transmitter 2 wires 12Vdc (note) mA Pt1000/NTC/PTC DI2 (note) Thermocouple Pt100 THERMOSTATS ANALOGUE CONTROLLERS 3 wires DI1 OP4 (note) OP1 OP3 * OP2 * SPECIAL CONTROLLERS AND “CUSTOM” T P PV TERMINALS C E L Pin connector: Stripped wire 1.4 mm - 0.055 in. max. L 5.5 mm - 0.21 in. q R O I R O - Neutral Line C NO 100... 240VAC/ Close 20... 30VDC C NO C NC NO Open Note: Terminal 4 can be programmed as: - Digital Input (DI2) connecting a free of voltage contact between terminals 4 and 11 - 0... 12 V SSR Drive Output (OP4) connecting the load between terminals 4 and 11 - 12 Vdc (20 mA) transmitter power supply connecting the transmitter between terminals 4 and 1 DIMENSIONS kr3 R O - 78 5 64 14 18 D S E N M - The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL Alarms Set Point Signal retransmission Serial communication Baud rate Working hours counters Wattmeter function EVOogreen Programmer (optional) Timer (optional) GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity PID single or double action, ON/OFF, ON/OFF with Neutral Zone Autotuning and Selftuning algorithms, Overshoot control 3 alarms programmable as absolute, deviation, band 4 programmable Set Points Measuring or Set Point retransmission TTL (standard) + RS485 (optional), ModBus RTU protocol 1200… 38400 baud A cumulative non-erasable counter and a second one resettable with alarm Instantaneous power, time consumption Stand-by mode of display, selectable Up to 8 segments with guaranteed soak Independent with 5 function modes ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS OUTPUTS Analogue input Transmitter PAC SYSTEMS Digital inputs CODE PREPROGRAMMED SYSTEMS Accuracy KR3 VERSION Controller Controller + Timer Controller + Timer + Programmer Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC, RTD, mA, V, mV/digital input 1 TC, NTC, PTC, mA, V, mV/digital input 1 OUT 1 Relay SPDT 4A Vdc for SSR driving 0/4… 20 mA, 0/2... 10V galvanically isolated (control and retransmission) OUT 2 Relay SPST 2A Vdc for SSR driving Not available OUT 3 Relay SPST 2A Vdc for SSR driving Not available OUT 4 Digital input 2 or digital output or transmitter supply RS485 Available Not available connection Plug-in screw type Plug-in screw type, fix part only Clamp type Fix screw type (standard) PLC AND OPERATOR PANELS Universal Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F), S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F) Infrared sensors: J or K Thermoresistances: 3 wires Pt 100 and 2 wires Pt 1000 (-200... 850°C/-328... 1562°F) Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V Thermocouples: J (-50… +1000°C/-58… 1832°F), K (-50… +1370°C/-58… 2498°F), S/R (-50… +1760°C/-58…3200°F), T (-70… +400°C/-94... 752°F) Infrared sensors: J or K Thermistors: PTC KTY81-121 (-55... +150°C/-67... 302°F), NTC 103 AT2 (-50... +110°C/-58... 230°F) Linear signals: 0/12… 60mV, 0/4… 20mA, 0/1… 5V, 0/2…10V ± 0.5% span ±1 digit, (±1% span ±1 digit for T/c S type) 1 or 2 according to instrument’s part number (the 2nd digital input is alternative to OUT 4) kr3 To compose the part number, pls. choose one of the option for each variable TIMERS COUNTERS POWER LIMITERS INPUTS CONNECTIONS INDICATORS Dual LED KR3 Main display: 4 digit h 11.7 mm. 3 colours: red, green and amber Secondary display: 4 green digit, h 7 mm I/O MODULES DISPLAY SUPERVISION HOW TO ORDER FEATURES 28 •3 dynamic colour led display •analogUE CONTROL OUTPUT •8 segmentS PROGRAMMER / Timer •WORKING hours counter 35 KR3 IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S 52 53 IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S Up to 4 (K31 and K32) Up to 2 (K38 and K39) Auxiliary power supply FUNCTIONAL Control PID functions Multi Set Point Program Timer Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Keyboard Mounting Connections ON/OFF, Neutral Zone, PID single and double action PID H/C control with overshoot control, Selftuning and 2 Autotuning algorithms Up to 4 pre-programmable Set Point Up to 8 segments with guaranteed soak Independent with 4 function modes Set Point -RS485 with ModBus-RTU (JBUS) protocol TTL ModBus 1200… 38400 baud, programmable -12 Vac/Vdc, 24 Vac/Vdc, 100… 240 Vac/Vdc ±10% (50/60 Hz) 6 VA approx. 78 x 35 mm - depth 64 mm 78 x 35 mm - depth 64 mm / 180 g approx. or 78.5 mm with plug-in terminals / 180 g approx. Mechanical Mechanical Mechanical or “Sensitive Touch” Flush in panel in 71 x 29 mm hole Plug-in terminals or Screw terminal block 2 x 1 mm² Screw terminal block 2 x 1 mm² IP 65, mounted on panel with gasket 0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F) 20… 85 RH% without condensation Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1) (*) K32: Capacitive Touch screen keyboard DIN RAIL MOUNTING CONTROLLERS THERMOSTATS ANALOGUE CONTROLLERS S T P F L H C E I V k38 / k39 R O M R O R O R O - DIMENSIONS k31 / k32 / k38 / k39 S - 78 6 12.2 78 64 35 Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or 12V ±20% 20 mA max. to drive SSR or 12V ±20% 20 mA max. to drive SSR OUT 3 and OUT 4: Relay SPST-NO (5A-AC1, 3A-AC3/250 Vac) or 12V ±20% 20 mA max. to drive SSR 12 Vdc/20 mA max. CODE SPECIAL CONTROLLERS AND “CUSTOM” Accuracy Digital inputs OUTPUTS K31 / K32 / K38 / K39 keyboard Mechanical Sensitive-Touch (*) - K32 only VERSION Controller Controller + Timer Controller + Timer + Programmer Power supply 12 Vac/Vdc 24 Vac/Vdc 100… 240 Vac INPUT TC,PT100,mV TC,PTC,NTC,mV 0/4… 20mA 0… 1V, 0/1… 5V, 0/2… 10V OUT 1 Relay SPDT 8A-AC1 Vdc for SSR driving Mosfet output (K31 only) OUT 2 Relay SPDT 8A-AC1 Vdc for SSR driving Not available OUT 3 (Solo K31 e K32) Relay SPST-NO 5A-AC1 Vdc for SSR driving Not available OUT 4 (Solo K31 e K32) Relay SPST-NO 5A-AC1 Vdc for SSR driving Not available Serial communication (K31 and K32) RS485 TTL ModBus PAC SYSTEMS 4 different configurations Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermoresistances: 3 wires Pt 100 (-200.. 850°C / -328... 1562°F) Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F) and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F) Linear signals 0/4… 20mA Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V ±0.5% fs + 1 digit; tc S ±1% fs + 1 digit 2 for free voltage contacts -- k31 / k32 To compose the part number, pls. choose one of the option for each variable PREPROGRAMMED SYSTEMS INPUTS CONNECTIONS PLC AND OPERATOR PANELS K39 Dual: 4 red and 4 green digit, h 7mm TIMERS COUNTERS POWER LIMITERS K38 Single: 4 red digit, h 12 mm + 3 LEDs Bargraph INDICATORS K32 Dual: 4 red and 4 green digit, h 7mm SUPERVISION Display K31 Single: 4 red digit, h 12 mm + 3 LEDs Bargraph 28 DISPLAY I/O MODULES HOW TO ORDER FEATURES 35 •Controller with independent timer •8 segments Programmer •wattmeter function ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS k 31/32/38/39 ACCESSORIES COMBUSTION CONTROL The dimensions are expressed in mm 54 55 24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz) 6 VA approx. 48 x 48 mm (1/16 DIN) - depth 98 mm / 180 g approx. Flush in panel in 45 x 45 mm hole Screw terminal block 2 x 1 mm² IP 65, mounted on panel with gasket 0… 50°C (32… 122°F)/-30… 70°C (-22… 158°F) 20… 85 RH% without condensation Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1) ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS ON/OFF, Neutral Zone, PID single and double action PID H/C control with overshoot control, Selftuning and 2 Autotuning algorithms Up to 4 pre-programmable Set Point Up to 8 segments with guaranteed soak Independent with 4 function modes TTL ModBus DIN RAIL MOUNTING CONTROLLERS CODE THERMOSTATS ANALOGUE CONTROLLERS T P L H SPECIAL CONTROLLERS AND “CUSTOM” K48/K49 VERSION Controller Controller + Timer Controller + Timer + Programmer Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC,PT100,mV TC,PTC,NTC,mV 0/4… 20mA 0… 1V, 0/1… 5V, 0/2… 10V OUT 1 Relay SPDT 8A-AC1 Vdc for SSR driving OUT 2 Relay SPDT 8A-AC1 Vdc for SSR driving Not available OUT 3/ digital INPUTS Relay SPST-NO 5A-AC1 Vdc for SSR driving 2 digital inputs Not available C E I V R O R O - DIMENSIONS k48 / k49 R O D - 9.5 48 98 AT ST SET Out1 Out2 - = + Out3 Out4 The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES Auxiliary power supply FUNCTIONAL Control PID functions Multi Set Point Program Timer Serial communication GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1 and OUT 2: Relay SPST-NO (8 A-AC1, 3 A-AC3 / 250 Vac) or 12V ± 20% 20 mA max. to drive SSR OUT 3: Relay SPST-NO (5 A-AC1, 3 A-AC3 / 250 Vac) or 12V ± 20% 20 mA max. to drive SSR 12 Vdc/20 mA max. K48 / k49 To compose the part number, pls. choose one of the option for each variable PAC SYSTEMS Up to 3 Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermoresistances: 3 wires Pt 100 (-200.. 850°C / -328... 1562°F) Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F) and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F) Linear signals 0/4… 20mA Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V ± 0.5 % fs + 1 digit; tc S ± 1% fs + 1 digit 2 for free voltage contacts, as alternative to OUT 3 CONNECTIONS PREPROGRAMMED SYSTEMS Accuracy Digital inputs OUTPUTS K49 Dual: 4 red and 4 green digit, h 7mm PLC AND OPERATOR PANELS 4 different configurations K48 Single: 4 red digit, h 12 mm + 3 LEDs Bargraph TIMERS COUNTERS POWER LIMITERS DISPLAY Display INPUTS INDICATORS HOW TO ORDER FEATURES 44.5 •Controller with independent timer •8 segments Programmer •wattmeter function 48 k 48/49 IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S 56 57 24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz) 6 VA approx. 4 DIN rail module, 70 x 84 mm - depth 60 mm / 230 g approx. On OMEGA DIN A rail Screw terminal block 2 x 1 mm² IP 40 0… 50°C (32… 122°F)/-30… 70°C (-22… 158°F) 20… 85 RH% without condensation Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1) ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS ON/OFF, Neutral Zone, PID single and double action PID H/C control with overshoot control, Selftuning and 2 Autotuning algorithms Up to 4 pre-programmable Set Point Up to 8 segments with guaranteed soak Independent with 4 function modes Set Point RS485 with ModBus-RTU (JBUS) protocol 1200… 38400 baud, programmable DIN RAIL MOUNTING CONTROLLERS CODE THERMOSTATS ANALOGUE CONTROLLERS T P SPECIAL CONTROLLERS AND “CUSTOM” L H R O R O - PAC SYSTEMS C E I V DIMENSIONS k85 70 R O - 1 2 3 4 5 27 6 7 21 12 8 9 10 11 12 Tun S - Prg Out1 Out2 - = + Out3 D 13 14 15 16 17 18 19 20 21 22 23 24 The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES Auxiliary power supply FUNCTIONAL Control PID functions Multi Set Point Program Timer Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1 and OUT 2: Relay SPDT (8 A-AC1, 3 A-AC3 / 250 Vac) or 12V ± 20% 20 mA max. to drive SSR OUT 3: Relay SPST-NO (5 A-AC1, 3 A-AC3 / 250 Vac) or 12V ± 20% 20 mA max. to drive SSR 12 Vdc/20 mA max. K85 VERSION Controller Controller + Timer Controller + Timer + Programmer Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC,PT100,mV TC,PTC,NTC,mV 0/4… 20mA 0… 1V, 0/1… 5V, 0/2… 10V OUT 1 Relay SPDT 8A-AC1 Vdc for SSR driving OUT 2 Relay SPDT 8A-AC1 Vdc for SSR driving Not available OUT 3/ Digital inputs Relay SPST-NO 5A-AC1 Vdc for SSR driving Not available Serial communication RS485 TTL ModBus INPUT digitale 2 digital inputs Not available PREPROGRAMMED SYSTEMS Up to 3 K85 To compose the part number, pls. choose one of the option for each variable PLC AND OPERATOR PANELS Accuracy Digital inputs OUTPUTS Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermoresistances: 3 wires Pt 100 (-200.. 850°C / -328... 1562°F) Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F) and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F) Linear signals 0/4… 20mA Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V ± 0.5 % fs + 1 digit; tc S ± 1% fs + 1 digit 2 for free voltage contacts CONNECTIONS TIMERS COUNTERS POWER LIMITERS 4 different configurations K85 4 red digit, h 12 mm + 3 LEDs Bargraph 60 DISPLAY Single INPUTS INDICATORS HOW TO ORDER FEATURES 45 •Controller with independent timer •8 segments Programmer •wattmeter function 84 k85 IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S 58 59 24 Vac/Vdc, 100… 240 Vac/Vdc ±10% (50/60 Hz) 6 VA approx. 78 x 35 mm - depth 75.5 mm or 78.5 mm with plug-in terminals / 180 g approx. On OMEGA DIN A rail Plug-in terminals or Screw terminal block 2 x 1 mm² 0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F) 20… 85 RH% without condensation Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1) ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS ON/OFF, Neutral Zone, PID single and double action PID H/C control with overshoot control, Selftuning and 2 Autotuning algorithms Up to 4 pre-programmable Set Point Up to 8 segments with guaranteed soak Independent with 4 function modes Del Set Point RS485 con protocollo ModBus-RTU (JBUS) 1200… 38400 baud, programmabile DIN RAIL MOUNTING CONTROLLERS CODE THERMOSTATS ANALOGUE CONTROLLERS T P SPECIAL CONTROLLERS AND “CUSTOM” L H C E I V R O R O - DIMENSIONS k30 21.55 R O R O S - 27.80 The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS Auxiliary power supply FUNCTIONAL Control PID functions Multi Set Point Program Timer Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Operating / storage temperature Operating humidity Conformity OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or 12V ±20% 20 mA max. to drive SSR OUT 3 and OUT 4: Relay SPST-NO (5A-AC1, 3A-AC3/250 Vac) or 12V ±20% 20 mA max. to drive SSR OUT 5: 12V ±20% 20 mA max. to drive SSR (always available on boartd) 12 Vdc/20 mA max. K30 VERSION Controller Controller + Timer Controller + Timer + Programmer Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC,PT100,mV TC,PTC,NTC,mV 0/4… 20mA 0… 1V, 0/1… 5V, 0/2… 10V OUT 1 / OUT 5 SSR (always on board) Relay SPDT 8A-AC1 Vdc for SSR driving OUT 2 Relay SPDT 8A-AC1 Vdc for SSR driving Not available OUT 3 Relay SPST-NO 5A-AC1 Vdc for SSR driving Not available OUT 4 Relay SPST-NO 5A-AC1 Vdc for SSR driving Not available Serial communication RS485 TTL ModBus PAC SYSTEMS Up to 5 k30 To compose the part number, pls. choose one of the option for each variable PREPROGRAMMED SYSTEMS Accuracy Digital inputs OUTPUTS CONNECTIONS PLC AND OPERATOR PANELS 4 different configurations K30 Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermoresistances: 3 wires Pt 100 (-200.. 850°C / -328... 1562°F) Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F) and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F) Linear signals 0/4… 20mA Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V ±0.5% fs + 1 digit; tc S ± 1% fs + 1 digit 2 for free voltage contacts 87.50 INPUTS TIMERS COUNTERS POWER LIMITERS HOW TO ORDER FEATURES 78.65 •Controller with independent timer •8 segments Programmer •wattmeter function 77.31 k30 IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S 60 61 Up to 4 Auxiliary power supply FUNCTIONAL Control PID functions 100… 240 Vac (-15...+10%) o 24Vac (-25...+12%) e 24Vdc (-15...+25%) (50/60Hz) 3VA max. 48 x 48 mm (1/16 DIN), depth 150 mm / 230 g approx. Flush in panel in 45 x 45 mm hole Screw terminal block M3 for cables with section 1 mm² (18AWG) IP65 0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F) 5… 95% RH without condensation EN 61010-1 RS485 SPECIAL FUNCTIONS Not available Programmer INSTRUCTION MANUAL Italian/English Not available FRONT FRAME COLOUR Dark grey (std) Dark grey shunt 0.1% SPECIAL EXECUTION Not available On DIN rail On DIN rail without display Tropicalized ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS PID, ON/OFF PID H/C control, Dead band, overshoot control, manual reset, cycle time, high and low limits, max. control output speed rate, Soft-start, safety output, forcing output, Fuzzy Tuning, Adaptive Tuning 1 Loop with single/double action with or without programmer Local + 2 stored Set points, only Remote, Local and Remote, Local with trim, Remote with trim, Time programmable 1 program, 16 segments, 1... 9999 cycles or continuous cycling (OFF) Integrated, Bumpless operated from keyboard, digital inputs and serial communication Motor travel time, motor minimum step Measuring or Set Point retransmission Isolated RS485 with ModBus-RTU (JBUS) protocol, with 2 wires 1200, 2400, 4800, 9600, 19200 bit/s, a 3 wires Not available Thermocouple External shunt 2.5W Pt100 00 01 02 03 04 05 50 51 52 53 DIN RAIL MOUNTING CONTROLLERS NO 100% POT C 0% NO Com. NO IL 2 C2 IL 1 V NPN TTL C1 DIMENSIONS m5 48 120 54 0 1 0 9 0 2 0 1 2 3 THERMOSTATS ANALOGUE CONTROLLERS mA SPECIAL CONTROLLERS AND “CUSTOM” mV 48 10 max. The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION Operating modes Set Point Program Auto/Man station Servomotor control Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1 and OUT 2: Relay NO, 2A/250Vac for resistive loads or Triac 1A/250Vac for resistive loads OUT 3: Relay NO, 2A/250Vac for resistive loads OUT 4: Analogue in current: 0/4…20mA max. 750Ω/10V max./ voltage: 0…1/5/10V 500Ω / 20mA max. (galvanically isolated) or 0…18Vdc, 20mA max. to drive SSR +18Vdc ±20%, 30mA max. for external transmitter (2, 3 or 4 wires) N C 18Vdc OUT 1 2 4 5 OPTIONS Not available Potentiometer Remote Set Point CT input Voltage for SSR driving/ Analogue output Voltage for SSR driving/ Analogue output+ Remote Set point Not available Potentiometer Remote Set Point CT input Voltage for SSR driving/ Analogue output L NO PAC SYSTEMS Digital inputs OUTPUTS RS485 3 5 PREPROGRAMMED SYSTEMS Auxiliary inputs (opt.) CODE PLC AND OPERATOR PANELS Accuracy M5 Power supply 100… 240 Vac 24 Vac/Vdc OUT 1 and out 2 Relay/Relay Relay/triac Triac/Relay Triac/triac Serial communication TIMERS COUNTERS POWER LIMITERS Universal Thermocouples: L/J (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F), K (0…+1200°C / 32…+2192°F), S/R (0... +1600°C / 32...2912°F) Thermoresistances: PT100 connection with 2 or 3 wires (-200... +600°C / -328... +1112°F) Linear signals: 0/10... 50 mV; 0/4…20 mA Infrared sensors or special ranges (custom) 0.25% ±1 digit (thermoelements) o 0.1% ±1 digit (for mA and mV) Non isolated remote Set Point: current 0/4… 20mA or voltage 1…5/ 0…5/ 0…10V Current Transformer for Heater Break function Potentiometer position feedback measurement 2 m5 To compose the part number, pls. choose one of the option for each variable INDICATORS INPUTS CONNECTIONS OP2 OP1 Double M5 Main display: 4 green digit, h 10 mm Secondary display: 4 green digit, h 8 mm + 8 LEDs CT DISPLAY I/O MODULES HOW TO ORDER FEATURES OP4 (REM) •process controller •analogue control output or servomotor output •16 segments Programmer OP3 m5 IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S 62 63 Digital inputs OUTPUTS Up to 6 Auxiliary power supply Alarms FUNCTIONAL Control PID functions Servomotor control Set Point Program Auto/Man station Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity PID, ON/OFF single or double action, Split range PID H/C control, Dead band, overshoot control, manual reset, cycle time, high and low limits, max. control output speed rate, Soft-start, safety output, forcing output, Fuzzy Tuning, Adaptive Tuning PID algorithm for 3 position Servomotor: Increase/Stop/Decrease according to: motor travel time, motor minimum step, Potentiometer Local + 3 stored Set points, only Remote, Local and Remote, Local with trim, Remote with trim, programmable (Remote Set Point mutally exclusive with frequency input) 4 programs, 16 segments, 1... 9999 cycles or continuous cycling (OFF) Integrated, Bumpless operated from keyboard, digital inputs and serial communication Measuring or Set Point retransmission Isolated RS485 with ModBus-RTU (JBUS) protocol MASTER and SLAVE - RS 485 asynchronous/isolated, PROFIBUS DP protocol RS 485 (MASTER or SLAVE) Up to 19.200 bit/s; PROFIBUS DP Up to 12Mb/s max. distance 100m (12Mb/s) C NPN 100% NO POT 0% REM SP 1 5 V V mA mV 0 1 5 6 7 8 0 1 4 6 7 THERMOSTATS ANALOGUE CONTROLLERS TTL Thermocouple mA OP6 (opt.) mA N/C IN2 (opt.) External shunt 2.5W Pt100 DIMENSIONS x5 48 110 0 4 0 9 96 0 2 10 max. 0 3 The dimensions are expressed in mm q5 96 100… 240 Vac (-15...+10%) or 24Vac (-25...+12%) and 24Vdc (-15...+25%) (50/60Hz) 5VA max. 48 x 96 mm (1/8 DIN), depth 110 mm / 250 g approx. 96 x 96 mm (1/4 DIN), depth 110 mm / 500 g approx. Flush in panel in 45 x 92 mm hole Flush in panel in 92 x 92 mm hole Screw terminal block M3 for cables with section 1 mm² (18AWG) IP65 0… 50°C (32… 122°F) / -20…+70°C (-4… 158°F) 5… 95% RH without condensation EN 61010-1 ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS OUT 1 and OUT 2: Relay NO, 2A/250Vac or Triac, 1A/250Vac, for resistive loads OUT 3: Relay SPDT, 2A/250Vac for resistive loads OUT 4: Relay NO, 2A/250Vac for resistive loads OUT 5 and OUT6: current: 0/4…20mA max. 750Ω/10V max. / voltage: 0…1/5/10V 500Ω / 20mA max. or 0/24Vdc ±10% - 30mA max. to drive SSR +24DC ±20% 30mA max. - for external transmitter Up to 4 alarms programmable as high/low, band alarm, deviation, Loop Break, Sensor Break 3 5 SPECIAL CONTROLLERS AND “CUSTOM” Auxiliary inputs CODE PAC SYSTEMS Frequency X5 / Q5 Power supply 100… 240 Vac 24 Vac/Vdc OUT 1, out 2, out 3, out 4 and out 5 Relay-Relay-Relay-Relay-logic/analogue Triac-triac-Relay-Relay-logic/analogue Serial communication Not available Mathematical package (MP) RS485 + MP RS485 Slave+Master+MP Profibus DP+MP RS485 + Profibus DP+MP OPTIONS Not available HZ input OUT 6 analogue OUT 6 analogue + Hz OUT 6 analogue + 300Hz input - (X5 only) SPECIAL FUNCTIONS Not available 4 Programs 16 segments INSTRUCTION MANUAL Italian/English Not available FRONT FRAME COLOUR Dark grey Dark grey + shunt 0.1% SPECIAL EXECUTION Not available Tropicalized PREPROGRAMMED SYSTEMS Universal Thermocouples: L/J/E (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F), K/N (0…+1200°C / 32…+2192°F), S/R (0... +1600°C / 32...2912°F), B (0... 1800°C / 32...3272°F), W3/W5 (0... 2000°C / 32... 3632°F) Thermoresistances: PT100 connection with 2 or 3 wires (-200... +600°C / -328... +1112°F) Linear signals: 0/4…20 mA, 0... 50mV/0... 300mV, 0/1... 5V/0... 10V Engineering units with or without decimal and square root extraction Infrared sensors or special ranges (custom) 0...2000 Hz, 0...20000 Hz; Remote Set Point not isolated (accuracy 0.1%) Current 0/4…20 mA Voltage 0/1... 5V/0... 10V Potentiometer position feedback measurement 3 for voltage contacts x5 / q5 To compose the part number, pls. choose one of the option for each variable OPERATOR PANELS INPUTS CONNECTIONS TIMERS COUNTERS POWER LIMITERS Q5 Main display (PV): 4 green digit, h 15 mm Secondary display (SP): 4 green digit, h 12 mm Third display (OUT): 4 green digit, h 9 mm INDICATORS Triple X5 Main display (PV): 4 green digit, h 12 mm Secondary display (SP): 4 green digit, h 7 mm Third display (OUT): 4 green digit, h 7 mm 110 I/O MODULES DISPLAY DIN RAIL MOUNTING CONTROLLERS HOW TO ORDER FEATURES 96 10 max. SUPERVISION •controller with profibus dp •Up to 6 OUTPUTS: 2 analogue OUTPUTS and 4 Set Points •programmer and mathematical package RS485 (Slave) x5 / q5 IND U S T R I A L A U T OM AT I O N | A D VA N CE D P R O GR A MME R CO N T R O L L E R S ACCESSORIES COMBUSTION CONTROL The dimensions are expressed in mm 64 65 din rail mounting controllers Versatile and compact A complete range of modules, which are open to the outside world with “Manager/Gateway” and with a wide range of operator interfaces. Modules plug and play for the control and the acquisition of analog and digital signals. 66 67 · · · K30 · K85 TLZ35 · · 1 · 1 · 1 · · 2 · · 2 Single display 4 digit Input Number of inputs Universal J-K-S-R-T + IR + PTC-NTC J-K-S-R-T + IR + Pt100 Digital For CT Relay or voltage for SSR drive outputs Analogue current or voltage outputs Measuring or Set Point retransmission Power supply 12 Vac/Vdc 24 Vac/Vdc 100… 240 Vac Control Loops Control 1 · 2 · 1 1+2 · · 2 4 1 · 2+2 5 4 · · · 1 · 1 · 2 · · · 1 · · · 1 · · · · · · · · · · · · 1 · 4 · · · 1 · · · · · · · · · · · · · · · ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS RS485 ModBus Slave Timer on board Start up Programmer CE certification UL approval ON/OFF and PID ON/OFF Servomotor control 1 · THERMOSTATS ANALOGUE CONTROLLERS D2 SPECIAL CONTROLLERS AND “CUSTOM” D3 PAC SYSTEMS D1 PLC AND OPERATOR PANELS Dimensions (mm) 78 x 35 22.5 x 99 1 DIN Module 70 x 84 4 DIN Modules TIMERS COUNTERS POWER LIMITERS FEATURES PREPROGRAMMED SYSTEMS din rail mounting controllers DIN RAIL MOUNTING CONTROLLERS ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS IND U S T R I A L A U T OM AT I O N | D IN R A IL MO U N T IN G CO N T R O L L E R S 68 69 IND U S T R I A L A U T OM AT I O N | D IN R A IL MO U N T IN G CO N T R O L L E R S INDUSTRIAL CONTROLLERS d1 / d2 / d3 Control PID functions PID algorithm for Servomotor Set Point Special functions Alarms Alarm functions Tuning Auto/Man station Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Front indications Dimensions / Weight Mounting Connections Protection degree Parameters access Operating / storage temperature Operating humidity Conformity -+24dc, ±20%, 30 mA max. - for external transmitter 1 Loop PID with overshoot control, ON/OFF single and double action (Heat-Cool) Double acquisitor, 2 loops PID with overshoot control or ON/OFF single action Dead band, overshoot control, manual reset, cycle time, max. control output speed rate, Soft-start, safety output -Optional -Local, Local + 2 stored, with tracking, Stand-by Local, Local + 2 stored Stand-by Timer, Start-up -Up to 3 Up to 4 Sensor break, Latching/Blocking, Loop break, Heater break associated to the timer (if available) Fuzzy Tuning One shot or Natural Frequency Integrated, Bumpless operated from digital input and serial communication Measuring or setpoint retransmission --(reference value) Isolated RS485 with Modbus RTU protocol RS 485 (MASTER or SLAVE) 1200, 2400, 4800, 9600 bit/s 3 wires 24Vac (-25… +12%), 24Vdc (-15… +25%) / 50/60Hz 4VA max. 3 red LEDs for DO + 1 green LED for PWR/COM 4 red LED for DO + 1 green LED for PWR/COM 22.5 x 99 mm, depth 114.5 mm / 159 g approx. On DIN A rail Power supply and comms: 0.08… 1.5 mm² (AWG28-AWG16) Inputs/Outputs: 0.2… 2.5 mm² (AWG24-AWG12) IP20 (terminal block) Tramite linea seriale e software di supervisione 0... 50°C (32… 122°F) / -20… 70°C (-4… 158°F) 5… 95 RH% without condensation EN61010-1 (IEC1010-1) 0 1 2 3 3 4 5 5 OP3 NO NO OP1 OP2 RS485 NC TTL N L IL Connector for power supply and serial communications bus (female) OP4 NO 0... 5V 24V NPN 24VDC External Shunt 2.5Ω mV 5 mA Pt100 d2 0 2 3 5 7 Plug with termination resistor for serial comm.s bus (male) OP1 OP2 OP3 OP4 Configuration and Supervision Power supply and serial communications bus connector (female) RS485 NC N L 0 2 0 9 0 2 mV External Shunt 2.5Ω mA IN2 NO External Shunt 2.5Ω IN1 Pt100 mV DIMENSIONS NPN mA Plug with termination resistor for serial communications bus (male) OP3 4…20mA Pt100 Configuration and Supervision OP5 mA NO NO OP1 OP2 RS485 OP4 NO 0... 5V 24V NPN N L IL TTL 22.5 TTL d3 NC d1/ d2 / d3 24V Power supply switch IL1 NO 0 3 24V Power supply switch Connector for power supply and serial communications bus (female) 24V Power supply switch 24VDC mV 99 DIN RAIL MOUNTING CONTROLLERS Plug with termination resistor for serial communications bus (male) Current transformer THERMOSTATS ANALOGUE CONTROLLERS 5 Configuration and Supervision NO SPECIAL CONTROLLERS AND “CUSTOM” CODE PAC SYSTEMS Outputs function Auxiliary power supply FUNCTIONAL OUT 1 and OUT 2: Relay NO, 2A res./250Vac (4A res./120Vac) / SSR, 1A res./250Vac, logic not isolated 0/5 Vdc OUT 3: Logic not isolated 0/5 Vdc NOT -- D1 / D2 / D3 Power supply 24 Vac/Vdc OUT 1 e 2 Relay (D1 only) Relay-Relay Relay-Vdc for SSR driving (D2 only) Triac (D1 only) Vdc for SSR driving-Vdc for SSR driving (Solo D2) Triac-triac (D2 only) Triac-triac (D1 and D3 only) Triac-Vdc for SSR driving (D2 only) Serial communication RS485 OPTIONS 1 Not available Servomotor (D3 only) Current transformer (D1 only) Analogue Out (D3 only) Servomotor + Analogue Out (D3 only) SPECIAL FUNCTIONS (D1 and D3 only) Not available Start-up + Timer INSTRUCTION MANUAL Italian/English Not available OPTIONS 2 Shunt 1% Shunt 0.1% OPTIONS 3 Not available Tropicalization PREPROGRAMMED SYSTEMS Up to 4 (D1) Up to 5 (D3) Up to 3 (D2) OUT 1 and OUT 2: Relay NO, 2A res./250Vac (4A res./120Vac)/SSR, 1A res./250Vac OUT 3: Relay NO, 2A res./150Vac OUT 4: Logic not isolated: 0...5 Vdc OUT 5: (D3 only) 0/4… 20 mA, 15V max. d1 To compose the part number, pls. choose one of the option for each variable PLC AND OPERATOR PANELS OUTPUTS CONNECTIONS TIMERS COUNTERS POWER LIMITERS Digital inputs D2 1 2 Thermocouples: L/J/E (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F), K/N (0…+1200°C/32…+2192°F), S/R (0... +1600°C / 32...2912°F), B (0... 1800°C / 32... 3272°F), Ni-NiMo (0... 1100°C / 32... 2012°F), W3, W5 (0... 2000°C / 32... 3632°F) Thermoresistances: PT100 (-99.9... 300.0°C / -99.9... 572.0°F and -200... 600°C / -328... 1112°F) Linear signals: 0/10...50 mV; 0/4...20 mA (shunt) Infrared sensors or special ranges (custom) Current transformer -1 voltage digital input 1 voltage digital input (+ 2 programmable) External Shunt 2.5Ω mA INDICATORS Auxiliary input D3 Pt100 SUPERVISION Universal D1 114.5 Note: these modules can be inserted into Profibus DP and DeviceNet nets, together with a DX module, with the possibility of automatic reconfiguration. 6.3 ACCESSORIES The dimensions are expressed in mm COMBUSTION CONTROL INPUTS Number of inputs I/O MODULES HOW TO ORDER FEATURES ADVANCED PROGRAMMER CONTROLLERS •1 or 2 loop controllers •single or double action •Up to 3 alarms + RS485 + ct INPUT 70 71 24 Vac/Vdc, 100… 240 Vac/Vdc ±10% (50/60 Hz) 6 VA approx. 78 x 35 mm - depth 75.5 mm or 78.5 mm with plug-in terminals / 180 g approx. On OMEGA DIN A rail Plug-in terminals or Screw terminal block 2 x 1 mm² 0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F) 20… 85 RH% without condensation Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1) ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS ON/OFF, Neutral Zone, PID single and double action PID H/C control with overshoot control, Selftuning and 2 Autotuning algorithms Up to 4 pre-programmable Set Point Up to 8 segments with guaranteed soak Independent with 4 function modes Del Set Point RS485 con protocollo ModBus-RTU (JBUS) 1200… 38400 baud, programmabile DIN RAIL MOUNTING CONTROLLERS CODE THERMOSTATS ANALOGUE CONTROLLERS T P SPECIAL CONTROLLERS AND “CUSTOM” L H C E I V R O R O - DIMENSIONS k30 21.55 R O R O S - 27.80 The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS Auxiliary power supply FUNCTIONAL Control PID functions Multi Set Point Program Timer Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Operating / storage temperature Operating humidity Conformity OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or 12V ±20% 20 mA max. to drive SSR OUT 3 and OUT 4: Relay SPST-NO (5A-AC1, 3A-AC3/250 Vac) or 12V ±20% 20 mA max. to drive SSR OUT 5: 12V ±20% 20 mA max. to drive SSR (always available on boartd) 12 Vdc/20 mA max. K30 VERSION Controller Controller + Timer Controller + Timer + Programmer Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC,PT100,mV TC,PTC,NTC,mV 0/4… 20mA 0… 1V, 0/1… 5V, 0/2… 10V OUT 1 / OUT 5 SSR (always on board) Relay SPDT 8A-AC1 Vdc for SSR driving OUT 2 Relay SPDT 8A-AC1 Vdc for SSR driving Not available OUT 3 Relay SPST-NO 5A-AC1 Vdc for SSR driving Not available OUT 4 Relay SPST-NO 5A-AC1 Vdc for SSR driving Not available Serial communication RS485 TTL ModBus PAC SYSTEMS Up to 5 k30 To compose the part number, pls. choose one of the option for each variable PREPROGRAMMED SYSTEMS Accuracy Digital inputs OUTPUTS CONNECTIONS PLC AND OPERATOR PANELS 4 different configurations K30 Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermoresistances: 3 wires Pt 100 (-200.. 850°C / -328... 1562°F) Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F) and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F) Linear signals 0/4… 20mA Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V ±0.5% fs + 1 digit; tc S ± 1% fs + 1 digit 2 for free voltage contacts 87.50 INPUTS TIMERS COUNTERS POWER LIMITERS HOW TO ORDER FEATURES 78.65 •Controller with independent timer •8 segments Programmer •wattmeter function 77.31 k30 IND U S T R I A L A U T OM AT I O N | D IN R A IL MO U N T IN G CO N T R O L L E R S 72 73 24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz) 6 VA approx. 4 DIN rail module, 70 x 84 mm - depth 60 mm / 230 g approx. On OMEGA DIN A rail Screw terminal block 2 x 1 mm² IP 40 0… 50°C (32… 122°F)/-30… 70°C (-22… 158°F) 20… 85 RH% without condensation Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1) ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS ON/OFF, Neutral Zone, PID single and double action PID H/C control with overshoot control, Selftuning and 2 Autotuning algorithms Up to 4 pre-programmable Set Point Up to 8 segments with guaranteed soak Independent with 4 function modes Set Point RS485 with ModBus-RTU (JBUS) protocol 1200… 38400 baud, programmable DIN RAIL MOUNTING CONTROLLERS CODE THERMOSTATS ANALOGUE CONTROLLERS T P SPECIAL CONTROLLERS AND “CUSTOM” L H R O R O - PAC SYSTEMS C E I V DIMENSIONS k85 70 R O - 1 2 3 4 5 27 6 7 21 12 8 9 10 11 12 Tun S - Prg Out1 Out2 - = + Out3 D 13 14 15 16 17 18 19 20 21 22 23 24 The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES Auxiliary power supply FUNCTIONAL Control PID functions Multi Set Point Program Timer Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1 and OUT 2: Relay SPDT (8 A-AC1, 3 A-AC3 / 250 Vac) or 12V ± 20% 20 mA max. to drive SSR OUT 3: Relay SPST-NO (5 A-AC1, 3 A-AC3 / 250 Vac) or 12V ± 20% 20 mA max. to drive SSR 12 Vdc/20 mA max. K85 VERSION Controller Controller + Timer Controller + Timer + Programmer Power supply 24 Vac/Vdc 100… 240 Vac INPUT TC,PT100,mV TC,PTC,NTC,mV 0/4… 20mA 0… 1V, 0/1… 5V, 0/2… 10V OUT 1 Relay SPDT 8A-AC1 Vdc for SSR driving OUT 2 Relay SPDT 8A-AC1 Vdc for SSR driving Not available OUT 3/ Digital inputs Relay SPST-NO 5A-AC1 Vdc for SSR driving Not available Serial communication RS485 TTL ModBus INPUT digitale 2 digital inputs Not available PREPROGRAMMED SYSTEMS Up to 3 K85 To compose the part number, pls. choose one of the option for each variable PLC AND OPERATOR PANELS Accuracy Digital inputs OUTPUTS Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermoresistances: 3 wires Pt 100 (-200.. 850°C / -328... 1562°F) Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F) and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F) Linear signals 0/4… 20mA Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V ± 0.5 % fs + 1 digit; tc S ± 1% fs + 1 digit 2 for free voltage contacts CONNECTIONS TIMERS COUNTERS POWER LIMITERS 4 different configurations K85 4 red digit, h 12 mm + 3 LEDs Bargraph 60 DISPLAY Single INPUTS INDICATORS HOW TO ORDER FEATURES 45 •Controller with independent timer •8 segments Programmer •wattmeter function 84 k85 IND U S T R I A L A U T OM AT I O N | D IN R A IL MO U N T IN G CO N T R O L L E R S 74 75 Relay operations FUNctional Control Acoustic alarm Defrosting control GENERAL Power supply Power consumption Dimensions / Weight Connections Mounting Front protection degree Operating / storage temperature Operating humidity Conformity INDUSTRIAL CONTROLLERS ON/OFF Internal buzzer (optional) At intervals time by stopping compressor 12, 24 Vac/Vdc, 100… 240 Vac ± 10% (50/60 Hz) 3 VA approx. 4 DIN rail modules - 70 x 84 x 60 mm / 150 g approx. Screw terminal block 2.5 mm² On OMEGA DIN A rail IP40, for internal use 0… +50°C (32… +122°F) /-25… +60°C (-13… +140°F) 30… 95 RH% without condensation Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1) Code F L H THERMOSTATS ANALOGUE CONTROLLERS OUT 1: Relay SPST-NO 16A -AC1(6A-AC3)/250 Vac or SPDT 16A- AC1(6A-AC3)/250 Vac OUT2: Relay SPDT 8A-AC1 (3A-AC3)/ 250 Vac 100000 operations for relay SPST-NO 16A and SPDT 8A - 50000 operations for relay SPDT 16A TLZ35 Power supply 12 Vac/Vdc 24 Vac/Vdc 100… 240 Vac OUT 1 Relay SPDT 16A-AC1 Relay SPST NO-16A-AC1 OUT 2 Relay Not available Buzzer (internal) Available Not available S R SPECIAL CONTROLLERS AND “CUSTOM” Up to 2 tlz35 To compose the part number, pls. choose one of the option for each variable R B - PAC SYSTEMS Digital input Accuracy OUTPUTS Termistori PTC KTY 81-121 (990Ω a 25°C) -50… +150°C (-58… +302°F) oppure Termistori NTC 103AT-2 (10kΩ a 25°C) -50… +109°C (-58… +228°F) 1 digital input for free voltage contacts ± 0.5 % fs COnnections dimensions PREPROGRAMMED SYSTEMS One TLZ35 4 red digit, o blu, h 12 mm tlz35 70 1 2 3 4 5 27 6 7 21 12 8 9 10 11 12 PLC AND OPERATOR PANELS DISPLAY Single INPUT DIN RAIL MOUNTING CONTROLLERS how to order features ADVANCED PROGRAMMER CONTROLLERS •THermostat •1 inPUT AND UP TO 2 OUTPUTS - = + 60 84 Prg Out1 Out2 45 Tun Out3 13 14 15 16 17 18 19 20 21 22 23 24 ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm TIMERS COUNTERS POWER LIMITERS tlZ35 IND U S T R I A L A U T OM AT I O N | D IN R A IL MO U N T IN G CO N T R O L L E R S 76 77 Thermostats analogue controllers Simple, reliable and cost effective ! Digital thermostats in different sizes for every application and analog controllers in the 1/16 DIN - 48 x 48 mm case. 78 79 Input PTC-NTC J-K Pt100 Digital Relay or voltage for SSR drive outputs Power supply Control TLZ35 E51A W09 TCPDE · · · · · 3 · · · 4 · 4 · 4 · 3 · 3 · · · · · · · 1 · · 1 · · 2 · · 2 · · · · 1 · 1 1 · · · · · · · · · · · · · · · · · · · · · · · · · · · · THERMOSTATS ANALOGUE CONTROLLERS TLZ11 · ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS TIMERS COUNTERS POWER LIMITERS CE certification UL approval ENEC approval (with “Sensitive Touch” keyboard only) 12 Vac/Vdc 12… 24 Vac/Vdc 24 Vac/Vdc 115 Vac 230 Vac 24… 240 Vac 100… 240 Vac ON/OFF PD TLZ10 · SPECIAL CONTROLLERS AND “CUSTOM” Single display Digit "Sensitive Touch" keyboard Z31A · PAC SYSTEMS Dimensions (mm) 78 x 35 68 X 35 48 x 48 75 x 122 70 x 84 4 DIN rail module PREPROGRAMMED SYSTEMS features PLC AND OPERATOR PANELS thermostats - analogue controllers DIN RAIL MOUNTING CONTROLLERS ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS IND U S T R I A L aut o m ati o n | T hE R MO S TAT s - A N A L O Gu e c o ntr o ll e rs 80 81 FUNCTIONAL Control Acoustic alarm GENERAL Power supply Power consumption Dimensions / Weight Keyboard Connections Mounting Front protection degree Operating / storage temperature Operating humidity INDUSTRIAL CONTROLLERS 12 Vac/Vdc, 12...24 Vac/Vdc, 100...240 Vac ±10% (50/60 Hz) 4 VA approx. 78 x 35 mm - depth 64 mm or 75.5 mm with plug-in terminals / 120 g approx. Mechanical or “Sensitive Touch” Screw terminal block 2.5 mm² or plu-in connector with screw terminals 2.5 mm² Flush in panel in 71 x 29 mm hole IP65, mounted in panel with gasket 0… +50°C (32… +122°F) /-25… +60°C (-13… +140°F) 30… 95 RH% without condensation Directive 2004/108/CE (EN55022: class B; EN61000- 4-2: 8KV air, 4KV cont.; EN61000-4-3: 10V/m; EN61000-4-4: 2KV supply, inputs, outputs; EN61000-4-5: supply 2KV com. mode, 1 KV\ diff. mode; EN61000-4-6: 3V), 2006/95/CE (EN 60730-1, EN 60730-2-7, EN 60730-2-9). Regulation 37/2005/CE (EN13485 air, S, A, 2,- 50°C +90°C wheter used with NTC 103AT11 probe). F G H S R B E N - dimensions z31a B 78 (*) Capacitive Touch screen keyboard DIN RAIL MOUNTING CONTROLLERS THERMOSTATS ANALOGUE CONTROLLERS S 6 12.2 78 64 35 Conformity ON/OFF Internal Buzzer (optional) Code SPECIAL CONTROLLERS AND “CUSTOM” Relay electrical life Z31A keyboard Mechanical Sensitive-Touch (*) Power supply 12 Vac/Vdc 12… 24 Vac/Vdc 100… 240 Vac OUT 1 Relay SPDT 16A-AC1 Relay SPST NO-16A-AC1 Buzzer (internal) Available Not available Connection Plug-in screw type Plug-in screw type, fix part only Fix screw type (standard) Display Blue Red (standard) PAC SYSTEMS One OUT 1: Relay SPDT or SPST-NO (16A - 1HP 250V, 1/2HP 125 Vac); EN 61810: 16 (9) A - EN 60730: 10 (4) A UL 60730: 12 A Res., 30 LRA, 5 FLA 12 A max. for plug-in version 100000 operations for SPST-NO 16A and SPDT 8A relays 50000 operations for SPDT 16A relay z31a / z31sa To compose the part number, pls. choose one of the option for each variable ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm PREPROGRAMMED SYSTEMS Accuracy OUTPUTS PTC KTY 81-121 (990Ω at 25°C) -50… +150°C (-58… +302°F) or NTC 103AT-2 (10kΩ at 25°C) -50… +109°C (-58… +228°F) ±0.5% fs + 1 digit COnnections 28 One Z31A 3 red or blue digit, h 15.5 mm 35 DISPLAY Single INPUTS PLC AND OPERATOR PANELS how to order FEATURES ADVANCED PROGRAMMER CONTROLLERS •THermostat 1 inPUT AND 1 OUTPUT •“Sensitive Touch” KEYBOARD TIMERS COUNTERS POWER LIMITERS Z31A IND U S T R I A L aut o m ati o n | T hE R MO S TAT s - A N A L O Gu e c o ntr o ll e rs 82 83 Relay electrical life FUNCTIONAL Regolazione Allarme acustico Controllo sbrinamento GENERAL Power supply Power consumption Dimensions / Weight Connections Mounting Front protection degree Operating / storage temperature Operating humidity Conformity INDUSTRIAL CONTROLLERS ON/OFF Internal buzzer (optional) At intervals time by stopping compressor 12, 24 Vac/Vdc, 100… 240 Vac ± 10% (50/60 Hz) 3 VA approx. 4 DIN rail modules - 70 x 84 x 60 mm / 150 g approx. Screw terminal block 2.5 mm² On OMEGA DIN A rail IP40, for internal use 0… +50°C (32… +122°F) /-25… +60°C (-13… +140°F) 30… 95 RH% without condensation Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1) Code F L H THERMOSTATS ANALOGUE CONTROLLERS OUT 1: Relay SPST-NO 16A -AC1(6A-AC3)/250 Vac or SPDT 16A- AC1(6A-AC3)/250 Vac OUT 2: Relay SPDT 8A-AC1 (3A-AC3)/ 250 Vac 100000 operations for relay SPST-NO 16A and SPDT 8A - 50000 operations for relay SPDT 16A TLZ35 Power supply 12 Vac/Vdc 24 Vac/Vdc 100… 240 Vac OUT 1 Relay SPDT 16A-AC1 Relay SPST NO-16A-AC1 OUT 2 Relay Not available Buzzer (internal) Available Not available S R SPECIAL CONTROLLERS AND “CUSTOM” Up to 2 tlz35 To compose the part number, pls. choose one of the option for each variable R B - PAC SYSTEMS Digital input Accuracy OUTPUTS Thermistors PTC KTY 81-121 (990Ω at 25°C) -50… +150°C (-58… +302°F) or Thermistors NTC 103AT-2 (10kΩ at 25°C) -50… +109°C (-58… +228°F) 1 digital input for free voltage contacts ± 0.5 % fs COnnections dimensions PREPROGRAMMED SYSTEMS One TLZ35 4 red digit, o blu, h 12 mm tlz35 70 1 2 3 4 5 27 6 7 21 12 8 9 10 11 12 PLC AND OPERATOR PANELS DISPLAY Single INPUT DIN RAIL MOUNTING CONTROLLERS how to order features ADVANCED PROGRAMMER CONTROLLERS •THermostat •1 inPUT AND UP TO 2 OUTPUTS - = + 60 84 Prg Out1 Out2 45 Tun Out3 13 14 15 16 17 18 19 20 21 22 23 24 ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm TIMERS COUNTERS POWER LIMITERS tlZ35 IND U S T R I A L aut o m ati o n | T hE R MO S TAT s - A N A L O Gu e c o ntr o ll e rs 84 85 Relay electrical life FUNctional Control GENERAL Power supply Power consumption Dimensions / Weight Connections Mounting Front protection degree Operating / storage temperature Operating humidity Conformity INDUSTRIAL CONTROLLERS ON/OFF 12 Vac/Vdc, 115, 230 Vac ±10% (50/60 Hz) 3 VA approx. 68 x 35 mm - depth 50 mm / 105 g approx. Screw terminal block 2.5 mm² Flush in panel in 58 x 25 mm hole IP65, mounted in panel with gasket 0… +50°C (32… +122°F) / -25… +60°C (-13… +140°F) 30… 95 RH% without condensation Directive 2004/108/CE (EN55022: class B; EN61000- 4-2: 8KV air, 4KV cont.; EN61000-4-3: 10V/m; EN61000-4-4: 2KV supply, inputs, outputs; EN61000-4-5: supply 2KV com. mode, 1 KV\ diff. mode; EN61000-4-6: 3V), 2006/95/CE (EN 60730-1, EN 60730-2-7, EN 60730-2-9) Code F C D THERMOSTATS ANALOGUE CONTROLLERS OUT 1: Relay SPDT or SPST-NO (16A-AC1, 6A-AC3 250 Vac, 1 HP 250 Vac, 1/2HP 125 Vac); 12 A max. for plug-in version 100000 operations for relay SPST-NO 16A and SPDT 8A, 50000 operations for relay SPDT 16A E51A Power supply 12 Vac/Vdc 115 Vac 230 Vac Input PTC NTC OUT 1 Relay SPDT 16A-AC1 Relay SPST-NO-16A-AC1 P N SPECIAL CONTROLLERS AND “CUSTOM” One e51a To compose the part number, pls. choose one of the option for each variable S R PAC SYSTEMS Accuracy Output PTC KTY 81-121 (990Ω at 25°C) -50… +150°C (-58… +302°F) or NTC 103AT-2 (10kΩ at 25°C) -50… +109°C (-58… +228°F) ±0.5% fs + 1 digit COnnections dimensions PREPROGRAMMED SYSTEMS One E51A 3 red or blue digit, h 14 mm e51a 65 5 50 PLC AND OPERATOR PANELS DISPLAY Display INput DIN RAIL MOUNTING CONTROLLERS how to order FEATURES ADVANCED PROGRAMMER CONTROLLERS •Thermostat •1 input and 1 output •small dimensions E 51 A 33 24.5 OUT SET ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm TIMERS COUNTERS POWER LIMITERS e51a IND U S T R I A L aut o m ati o n | T hE R MO S TAT s - A N A L O Gu e c o ntr o ll e rs 86 87 Mounting Front protection degree Operating / storage temperature Operating humidity Conformity INDUSTRIAL CONTROLLERS ON/OFF At intervals time by stopping compressor Internal Buzzer (optional) 100...240 Vac ±10% (50/60 Hz) 3 VA approx. 75 x 122 mm - depth 34 mm / 120 g approx. Screw terminal block for cables 0.2...1.5 mm² / AWG 24...16 On wall. Cables outlet: on the back side or lateral side by PG9 cable gland IP40 0… +50°C (32… +122°F) / -25… +60°C (-13… +140°F) 30… 95 RH% without condensation Directive 2004/108/CE (EN55022: class B; EN61000- 4-2: 8KV air, 4KV cont.; EN61000-4-3: 10V/m; EN61000-4-4: 2KV supply and relay outputs, 1KV inputs; EN61000-4-5: supply 2KV com. mode, 1 KV\ diff. mode; EN61000-4-6: 3V); Directive 2006/95/CE (EN 60730-1, EN 60730-2-9). Regulation 37/2005/CE (EN13485 air, S, A, 2,- 50°C +90°C wheter used with NTC 103AT11 probe). Regulation 37/2005/CE (EN13485 air, S, A, 2,- 50°C +90°C wheter used with NTC 103AT11 probe). Code THERMOSTATS ANALOGUE CONTROLLERS H R B - SPECIAL CONTROLLERS AND “CUSTOM” FUNCTIONAL Control Defrosting control Acoustic alarm GENERAL Power supply Power consumption Dimensions / Weight Connections OUT1: Relay SPDT 8A, 1/2HP 250V, 1/3 HP 125 Vac - EN 61810: 8 (3) A - EN 60730: 8 (4) A - UL 60730: 10A Res., 12 LRA, 2 FLA W09 POWER SUPPLY 100… 240Vac OUT 1 Relay SPDT-8A-AC1 Buzzer (internal) Available Not available Connection Screw type Display Blue Red (standard) B - PAC SYSTEMS One w09 To compose the part number, pls. choose one of the option for each variable DIMENSIONS w09 75 34 PREPROGRAMMED SYSTEMS Accuracy OUTPUTS Thermistors PTC KTY 81-121 (990Ω at 25°C) -50… +150°C (-58… +302°F) or Thermistors NTC 103AT-2 (10kΩ at 25°C) -50… +109°C (-58… +228°F) ±0.5% fs + 1 digit CONNECTIONS PLC AND OPERATOR PANELS One W09 3 red or blue digit, h 15.5 mm 122 DISPLAY Single INPUTS DIN RAIL MOUNTING CONTROLLERS how to order FEATURES ADVANCED PROGRAMMER CONTROLLERS •Thermostat 1 INPUT and 1 output •wall Mounting 16 ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm TIMERS COUNTERS POWER LIMITERS w09 IND U S T R I A L aut o m ati o n | T hE R MO S TAT s - A N A L O Gu e c o ntr o ll e rs 88 89 INDUSTRIAL CONTROLLERS 24… 240 Vac ±10% (50/60 Hz) 3 VA approx. 48 x 48 mm (1/16 DIN) - depth 89 mm / 200 g approx. Faston 6.3 mm terminals or Octal socket Flush in panel in 45.5 x 45.5 mm hole IP 54, mounted on panel with gasket 0… +50°C (32… +122°F) / -25… +60°C (-13… +140°F) 30… 95 RH% without condensation Directive EMC 2004/108/CE (EN 61326), Directive BT 2006/95/CE (EN 61010-1) DIN RAIL MOUNTING CONTROLLERS CODE SPECIAL CONTROLLERS AND “CUSTOM” THERMOSTATS ANALOGUE CONTROLLERS 1 2 3 4 6 7 8 9 U J K P PAC SYSTEMS GENERAL Power supply Power consumption Dimensions / Weight Connections Mounting Front protection degree Operating / storage temperature Operating humidity Conformity ON/OFF, PD Ranges available from 100 to 1200°C: 0… 100°C (Pt100 only) 0… 200°C 0… 250°C 0… 350°C 0… 600°C 0… 1000°C 0… 1100°C 0… 1200°C TCPDE m ranges 0… 100°C (PT100 only) 0… 200°C 0… 350°C 0… 600°C 0… 1000°C 0… 1200°C 0… 250°C 0… 1100°C Power supply 24… 240 Vac INPUT J K PT100 output Relay 0… 12 V for SSR driving wiring diagram Thermocouples Thermoresistances (*) Thermocouples Thermocouples Thermocouples Connections Faston Octal control ON/OFF PD tcpde M - pt100 INPUT R T PREPROGRAMMED SYSTEMS Ranges OUT 1: Relay 8A-AC1 (3A-AC3)/250Vac or 20 mA/12 Vdc to drive SSR tcpde M - tc INPUT To compose the part number, pls. choose one of the option for each variable 31 32 33 34 35 PLC AND OPERATOR PANELS Accuracy OUTPUT One FUNCTIONAL Control CONNECTIONS F O O P TIMERS COUNTERS POWER LIMITERS 2 different configurations TCPDE m Thermocouples J, K Thermoresistances Pt 100 IEC ±5% f.s. DIMENSIONS tcpde M (*) max. range for PT100 input: 350°C 48 48 11 INDICATORS INPUTS 6 T Faston TCPDE 70 11 6 15 3 5 10 Octal 70 18 I/O MODULES how to order FEATURES ADVANCED PROGRAMMER CONTROLLERS •analogue controller •ON/OFF and PD control •ranges from 100 to 1200°C SUPERVISION tcpde m IND U S T R I A L aut o m ati o n | T hE R MO S TAT s - A N A L O Gu e c o ntr o ll e rs ACCESSORIES COMBUSTION CONTROL The dimensions are expressed in mm 90 91 special controllers and “custom” The only limit is your imagination... Our production program includes many models that can be used in specific applications such as controllers for Peltier cells, differential controllers, controllers dedicated to the bakery sector and also “custom” products to meet specific customer requirements. 92 93 IND U S T R I A L A U T OM AT I O N | S P EC I A L CO N T R O L L E R S A ND “c ust o m” SPECIAL controllers and “custom” FEATURES Dimensions (mm) TCO30 78 x 35 72 x 144 Single display Triple display Digit Inputs · · J-K Pt100 2 wires TC J,K,S, IR + PT100 TC J,K,S, IR + PTC, NTC 0/4… 20mA 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V Relay outputs Voltage output 12… 24 Vdc and Vdc for SSR driving (10mA/Vdc) 24, 115, 230 Vac Power supply 12… 24 Vdc ON/OFF Peltier cells: PID double action, Control Autotuning FAST, Selftuning, Fuzzy overshoot control RS485 8 programs CE certification UL approval 94 TLK33 · · 3+3+4 · · 4 · · · · 7 2 · · · · · · · · · 95 Approx. 7 years by means of internal battery RS485 isolated, ModBus RTU 2400… 38400 baud 24, 115, 230 Vac ± 10% (50/60 Hz) 9 VA approx. 72 x 144 mm, depth 77 mm / 600 g approx. Flush in panel in 68 x 139 mm hole Screw terminal block 2.5 mm² 0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F) 20… 95 RH% without condensation ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS ON/OFF 8 cooking programs DIN RAIL MOUNTING CONTROLLERS CODE D C D C A A R V - DIMENSIONS tco30 S 72 9 68 I - 144 FUNCTIONAL Control Programs Internal clock lifetime memory without power supply Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Operating / storage temperature Operating humidity OUT STEAM: 1 Relay SPST-NO (16 A-AC1, 6 A-AC3 / 250 Vac) Other OUTS: Relay SPST-NO (8 A-AC1, 3 A-AC3 / 250 Vac) TCO30 INPUT PT100 J-K Power supply 230 Vac 115 Vac 24 Vac auxiliary probe input Available Not available AUXILIARY OUTPUT Available Not available STEAM PROBE INPUT Relay Vdc for SSR driving Serial communication RS485 Not available 3 Digital inputs Available Not available THERMOSTATS ANALOGUE CONTROLLERS Up to 7 Thermocouples: J/K (-50 ... +999 °C/-58 …+999 °F) Thermoresistances: Pt 100 2 wires (-50... +600°C/-58… +999°F) 3, for free voltage contacts tco30 To compose the part number, pls. choose one of the option for each variable SPECIAL CONTROLLERS AND “CUSTOM” INPUTS Up to 4: Top, Floor, Steamer and auxiliary probe Digital inputs OUTPUTS CONNECTIONS PAC SYSTEMS Triple TCO30 2 temperature indications: 3 red digit, h 14 mm 1 time indication: 4 red digit, h 7 mm ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm PREPROGRAMMED SYSTEMS DISPLAY PLC AND OPERATOR PANELS HOW TO ORDER FEATURES TIMERS COUNTERS POWER LIMITERS •Controller for cooking ovens •up to 8 programs •Up to 4 INPUTS for top, floor steamer and Auxiliary probe 135 TCO30 IND U S T R I A L A U T OM AT I O N | S P EC I A L CO N T R O L L E R S A ND “c ust o m” 96 97 IND U S T R I A L A U T OM AT I O N | S P EC I A L CO N T R O L L E R S A ND “c ust o m” INDUSTRIAL CONTROLLERS peltier cells controller DIN RAIL MOUNTING CONTROLLERS 0..50/60 mV 0/1..5 V 0...1 V 0/2..10 V 0/4..20 mA ACTIVE 4..20 mA PASSIVE (2 wires) 4..20 mA ACTIVE OUT 12 VDC Max 20 mA PTC-NTC RS 485 DIG IN2 DIG IN1 B GND A + Pt100 2 3 4 5 6 7 8 9 10 11 12 SPECIAL CONTROLLERS AND “CUSTOM” 1 INPUT SSR:10mA/10VDC TLK 33 O 13 14 15 16 17 18 19 20 21 22 23 24 C S - AL1 AL2 PELTIER MODULE + HEAT 7A MAX. dimensions tlk33 I - TLK33 : When the RS485 is required, 2 digital inputs are always on board too. + COOL 78 6 12.2 28 O - SUPPLY 12..24 VDC PAC SYSTEMS O - 78 64 ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm PREPROGRAMMED SYSTEMS TC/mV PLC AND OPERATOR PANELS D E I V ext. gen. THERMOSTATS ANALOGUE CONTROLLERS G 35 12… 24 Vdc ±10% 4 VA approx. 78 x 35 mm - depth 75.5 mm / 130 g approx. Screw terminal block 2.5 mm² Flush in panel in 71 x 29 mm hole IP65, mounted in panel with gasket 0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F) 20… 85 RH% without condensation Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1) Code 35 PID dual action, Autotuning FAST, Selftuning algorithms, Fuzzy overshoot control 4 Set Points programmable RS485 with Modbus RTU protocol 1200… 38400 baud, programmable TLK33 power supply 12… 24 Vdc InPUT PT100 + TC (J,K,S,IRS), mV PTC,NTC,mV + TC (J,K,S,IRS) 0/4… 20mA 0/1… 5V, 0/2… 10V control oOUTPUTS ( 2 FOR SSR ) 12… 24 Vdc for Peltier cells (7A max) OUT AL1 Vdc for SSR driving Not available OUT AL2 Vdc for SSR driving Not available serial Communication RS485 + 2 digital inputs Not available digital INPUT Available Not available + 12… 24 Vdc (equal to power supply) to direct drive Peltier cells max. 7A; up to 2 alarm outputs in voltage for SSR driving (10mA/ 10Vdc) 12 Vdc / 20 mA max. tlk33 To compose the part number, pls. choose one of the option for each variable - Digital inputs Accuracy OUTPUTS Up to 2, in voltage to direct drive Peltier cells Auxiliary supply FUNctional Control Set Point Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Connections Mounting Front protection degree Operating / storage temperature Operating humidity Conformity Thermocouples (0... 1000°C/32... 1832°F), K (0… 1370°C/32... 2498°F), S,R (0… 1760°C/32... 3200°F), T (0... 400°C/32… 752°F) and Infrared sensors J or K type + Thermoresistances Pt 100 3 wires (-200.. 850°C/-328... 1562°F) Thermocouples J (0... 1000°C/32... 1832°F), K (0… 1370°C/32... 2498°F), S,R (0… 1760°C/32... 3200°F), T (0... 400°C/32… 752°F) and Infrared sensors J or K type + Thermistors PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C/-67... 302°F) and Thermistors NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C/-58... 230°F) Linear signals 0/4… 20mA Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V 2 digital inputs for free voltage contacts ± 0,5% span ±1 digit, Tc S :±1% span ±1 digit COnnections I 4 different configurations TLK33 4 red digit, h 12 mm + + DISPLAY Single INPUTS TIMERS COUNTERS POWER LIMITERS how to order features ADVANCED PROGRAMMER CONTROLLERS •PID control •up to 2 outputs •RS485 98 99 pac systems The right solution for every application! New generation of programmable controllers (PAC - Programmable Automation Controller). They manage the control, the monitoring and permit the remote control of machines and small industrial plants. Within Sigma2 line, two hardware solutions are available: one modular and distributed (SigmaPAC: CU02) and one compact (MicroPAC: M81, MP02). 100 101 pac systems Power supply Control ON/OFF, PID con Autotuning avanzato Controllo Attuatori motorizzati Processor ARM 32 bit 16 MB RAM, 2MB program and 64 KB flash USB port Real Time Clock Ethernet port (communication, programming, configuration) RS485 port RS232 port Modbus RTU (Master/Slave) protocol, Modbus TCP Server, ASCII Profibus DP Programming languages : IL, ST, FBD, LD, SFC, CFC Advanced libraries dedicated to process control CE certification UL approval (listed) (*) with expansion units - see hereunder models 1 1 8+32 (*) 4 2 · · 4 · · · · · · · · · 1 · · · · · · · · · · · · 1 · · · · · · · · · · 2 · · · · · · SPECIAL CONTROLLERS AND “CUSTOM” 6+2 8 + 32 (*) 2 ACCESSORIES COMBUSTION CONTROL SUPERVISION Digital expansion units: MPD10808 (8 inputs 24 Vdc + 8 outputs 24 Vdc, 0.5A) MPD11616 (16 inputs 24 Vdc + 16 outputs 24 Vdc, 0.5A) MPD20808 (8inputs 24 Vdc + 8 relays outputs 2A) MPD40808 (8 inputs 120 Vac + 8 relays outputs 2A) THERMOSTATS ANALOGUE CONTROLLERS 2 8 4 12 10 24 Vac/Vdc 24 Vdc · PAC SYSTEMS Relay or voltage outputs Analogue outputs (current or voltage) Analogue outputs (voltage only) · PREPROGRAMMED SYSTEMS Inputs (16 bit) CU02 PLC AND OPERATOR PANELS Ingresso universale NTC-PT1000 0/4… 20 mA, 0/1… 5V, 0… 10V Digitali Potenziometro Raziometrico (5V) MP02 TIMERS COUNTERS POWER LIMITERS Dimensions (mm) M81 · INDICATORS 10 moduli DIN (175 x 110 mm) 8 moduli DIN (152 x 110 mm) I/O MODULES features DIN RAIL MOUNTING CONTROLLERS ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS IND U S T R I A L A U T OM AT I O N | PA C S Y S T EM S 102 103 4 Analogue 10 Digital functional Processor Memory Programming languages Standard Real time clock Minimum time of cycle execution Serial ports Protocols GENERAL Power supply Power consumption Dimensions / Weight Mounting Front protection degree Operating / storage temperature Operating humidity ARM 32 bit 16 MB of RAM system, application memory max. 2 MB internal + 3.5 MB on USB key 64 kB redundant FLASH memory IL, ST, FBD, LD, SFC, CFC IEC61131-3 on board 10ms Ethernet + RS485 + RS232/485 Modbus RTU (Master/Slave), Modbus TCP Server, ASCII 24 Vac/Vdc (-15... +25%) (50/60 Hz) 13 VA (+6.5 VA with I/O modules) 175 x 110 mm, depth 60 mm / 450 g approx. On OMEGA DIN A rail IP 20 0… 50°C (32… 122°F) / -40…+70°C (-40… 158°F) 5… 95 RH% without condensation 5 R O Q DIN RAIL MOUNTING CONTROLLERS PC TABLET HMI CELL PHONES USB KEY MODEM Remote I/O ROUTER INPUTS M81 R O Q OUTPUTS REMOTE SUPERVISOR R V - dimensions m81 U 1 2 110 M81 60 175 E N 60 Rail mounting DIN 35 x 7.5 (EN 50022) The dimensions are expressed in mm CABLES Ethernet CABLE 2m, programm. CU, PC-RJ45/CU-RJ45 POWER ADAPTOR 3.2 A POWER ADAPTOR 5 A ACCESSORIES COMBUSTION CONTROL SUPERVISION POWER ADAPTORS APS2 ALDR75-24 APS2 ALDR12024 internet cloud THERMOSTATS ANALOGUE CONTROLLERS Code accessories APS2 CABLECUPROG ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS 4x 0... 10 V Resolution 16 bit Accuracy: 0.5% of span Load >1kΩ Insulation 800 V between power supply and logic 10 relay digital outputs channels (2 relays SPDT-5A, 8 relays SPST-NO 2A) Insulation 2500V channels to power supply and channels to logic M81 analogue inputs 0/4… 20mA 0/5 Volt, ratiometrics OUT 1 Relay SPDT 5A Vdc for SSR driving SSR 2A 250 Vac OUT 2 Relay SPDT 5A Vdc for SSR driving SSR 2A 250 Vac OUT 7…10 Relay SPST 2A Not available analogue outputs 1…4 0… 10V Not available USB port Available Not available communication ports COM 1 RS485/232 COM1 RS485/232 + COM2 RS485 reserved part no. connections Plug-in screw type Plug-in screw type, fix part only SPECIAL CONTROLLERS AND “CUSTOM” outputs m81 To compose the part number, pls. choose one of the option for each variable PAC SYSTEMS 12 Digital COnnections PREPROGRAMMED SYSTEMS 12 Analogue M81 8x Thermistors NTC 103AT-2, Thermoresistances Pt1000 and 4x Linear signals 0/1... 5V, 0/2… 10V, 0/4... 20 mA, ratiometrics Resolution: 16 bit Accuracy: 0.5% of span Input impedance >100kΩ (V); 300Ω (mA) Insulation 2500V channels to power supply and channels to logic (High level analogue signals) Insulation 800 V between power supply and logic (Sensors) 12 digital inputs for free voltage contacts Insulation 800 V between power supply and logic Compliant to IEC/EN 61131-2 (type 1) PLC AND OPERATOR PANELS inputs TIMERS COUNTERS POWER LIMITERS how to order features INDICATORS •compact PROGRAMMABLE controller (micropac) •8 + 4 A/i •12 d/i + 10 d/o •4 a/o I/O MODULES m81 sigma2 IND U S T R I A L A U T OM AT I O N | PA C S Y S T EM S 104 105 Memory Programming languages Standard Real time clock Execution cycle Minimum time Serial ports Protocols GENERAL Power supply Power consumption Dimensions / Weight Mounting Front protection degree Operating / storage temperature Operating humidity 24 Vdc (-15... +25%) / 50/60 Hz 13 VA (+3.5 VA with both expansion units) 152 x 110 mm, depth 66 mm / 460 g approx. On OMEGA DIN A rail IP 20 0… 50°C (32… 122°F) / -40…+70°C (-40… 158°F) 5… 95 RH% without condensation Note: MP02 unit can be expanded up to 2 I/O modules through the side connector and via one of the RS485 ports by using the Modbus I/O modules. DIN RAIL MOUNTING CONTROLLERS THERMOSTATS ANALOGUE CONTROLLERS internet cloud CELL PHONES ROUTER INPUTS REMOTE SUPERVISOR OUTPUTS - dimensions PREPROGRAMMED SYSTEMS - PAC SYSTEMS 0 1 2 mp02 2 - 65.8 M 76 45.2 152 20.6 22 accessories The dimensions are expressed in mm CABLES APS2 CABLECUCONF APS2 CABLECUPROG POWER ADAPTORS APS2 ALDR75-24 APS2 ALDR12024 filters APS2 FILTRI PLUGS APS2 SPINAM11 APS2 SPINAV11 APS2 SPINAM14 APS2 SPINAV14 RS232 CABLE 2m, config. CU, PC-DB9F/CU-RJ45 Ethernet CABLE 2m, programm. CU, PC-RJ45/CU-RJ45 POWER ADAPTOR 3.2 A POWER ADAPTOR 5 A FERRITES + FILTERS PLUG WITH 11 polE CLAMP TERMINALS PLUG WITH 14 polE SCREW TERMINALS PLUG WITH 11 polE CLAMP TERMINALS PLUG WITH 14 polE SCREW TERMINALS PLC AND OPERATOR PANELS - MODEM Remote I/O SPECIAL CONTROLLERS AND “CUSTOM” HMI ACCESSORIES Digital expansion units: MPD10808 (8 inputs 24 Vdc + 8 outputs 24 Vdc, 0.5A) MPD11616 (16 inputs 24 Vdc + 16 outputs 24 Vdc, 0.5A) MPD20808 (8inputs 24 Vdc + 8 relays outputs 2A) MPD40808 (8 inputs 120 Vac + 8 relays outputs 2A ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS ARM 32 bit 16 MB of RAM system, application memory max. 2 MB internal, 64 kB redundant FLASH memory IL, ST, FBD, LD, SFC, CFC IEC61131-3 on board ≥5ms (10ms tipical) Ethernet + RS485 + RS232/485 Modbus RTU (Master/Slave), Modbus TCP Server, ASCII TABLET TIMERS COUNTERS POWER LIMITERS functional Processor PC INDICATORS 8+32 Digital 0 1 2 I/O MODULES 0/2/4 analogue ±10 V (±25 mA max.), 0/4... 20 mA Resolution: 13 bit Accuracy: 0.1% of span Insulation 800 V between power supply and logic 8 + 32 (with expansion units) 24Vdc, 0.5 A or 8 + 8/16 relays (2A, 240 Vac, NA) Source type (PNP) Protection: Reverse polarity and short circuit Insulation 800V between channels and power supply Code SUPERVISION outputs MP02 analogue inputs 6 ch - 0/4… 20mA, Volt 8 ch - 0/4… 20mA, Volt 6 ch - 0/4… 20mA, Volt + Universal channels reserved part no. reserved part no. reserved part no. analogue outputs 1…4 Not available 2 ch. - 0/4… 20mA, Volt 4 ch. - 0/4… 20mA, Volt USB port Not available communication ports COM1 RS485/232 + COM2 RS485 reserved part no. connections Clamp type 69.3 8+32 digital mp02 To compose the part number, pls. choose one of the option for each variable 12.7 2 universal analogue COnnections 46.2 6 analogue MP02 6x 0...10V, 0/1...5V, 0...1V - 0/4...20mA Resolution: 16 bit Accuracy: 0.1% of span Input impedance >100kΩ (V); 300Ω (mA) Insulation 800 V between power supply and logic ±15 mV, ± 35mV, ±50 mV, ±100 mV, ±300 mV, ±1.25 V, TC (L, J, T, K, S, R, N), Pt100, Pt1000 and potentiometer (0.1... 10kΩ) Resolution: 16 bit Accuracy: 0.1% of span Input impedance >10 MΩ (V) Insulation 800 V between power supply and logic 40 Vpp between the channels (differential inputs) 8 + 32 (with expansion units) 24 Vdc (ON: 5...30V, OFF: 0..3V) or 8 + 8/16 max. 120 Vac Counter input 80 Hz max. frequency Sink type Protection: Reverse polarity and overvoltage Insulation 800 V between power supply and logic 46.2 inputs COMBUSTION CONTROL how to order features 40.7 •compact PROGRAMMABLE COntroller (micropac) + on board I/O and expansion capability •8 a/i + 8 d/i •4 a/o + 8 d/o 110 mp02 sigma2 IND U S T R I A L A U T OM AT I O N | PA C S Y S T EM S 106 107 IND U S T R I A L A U T OM AT I O N | PA C S Y S T EM S INDUSTRIAL CONTROLLERS mp-d 1/2/4 Mounting Front protection degree Connections Operating / storage temperature Operating humidity 8 relay outputs 2A, NO MP-D1/16-16/M0 16 inputs (24 Vdc) 16 outputs (24 Vdc, 0.5A) 76 x 110 mm, depth 66 mm / 220 g On OMEGA DIN A rail IP 20 Terminal block with CLAMP connectors 0… +50°C (32… +122°F) / -20…+85°C (-4… +185°F) 5… 95 RH% without condensation 152 x 110 mm, depth 66 mm / 350 g mp-d1 / mp-d2 / mp-d4 To compose the part number, pls. choose one of the option for each variable expansion units - Sigma2 microPAC MP-D1/08-08/M0 MP-D1/16-16/M0 24 Vdc (-15... +25%) (50/60 Hz) 4 VA COnnections DIN RAIL MOUNTING CONTROLLERS 8 outputs (24 Vdc, 0.5A) MP-D4/08-08/M0 8 inputs (120 Vac) MP-D2/08-08/M0 MP-D4/08-08/M0 8 digital inputs 24Vdc optoisolated + 8 digital outputs 24V 0.5V optoisolated 16 digital inputs 24Vdc optoisolated + 16 digital outputs 24V 0.5V optoisolated 8 digital inputs 24Vdc + 8 digital outputs 230Vac/2A relay SPST-NO 8 digital inputs 120Vac + 8 digital outputs 230Vac/2A relay SPST-NO PC TABLET HMI internet cloud CELL PHONES ROUTER THERMOSTATS ANALOGUE CONTROLLERS Dimensions / Weight MP-D1/08-08/M0 MP-D2/08-08/M0 8 inputs (24 Vdc) MODEM Remote I/O INPUTS REMOTE SUPERVISOR OUTPUTS PAC SYSTEMS inputs Digital outputs Digital GENERAL Power supply Power consumption SPECIAL CONTROLLERS AND “CUSTOM” how to order features ADVANCED PROGRAMMER CONTROLLERS •expansion units for micropac MP02 PREPROGRAMMED SYSTEMS dimensions mp-d1 / mp-d2 / mp-d4 20.6 46.2 22 ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm PLC AND OPERATOR PANELS 69.3 45.2 152 TIMERS COUNTERS POWER LIMITERS 76 40.7 46.2 110 12.7 65.8 108 109 IND U S T R I A L A U T OM AT I O N | PA C S Y S T EM S 0 2 5 DIN RAIL MOUNTING CONTROLLERS ROUTER MODEM internet cloud OUTPUTS PC TABLET HMI 1 CELL PHONES 0 /ABA PAC SYSTEMS 0 9 dimensions available models 65.8 76 40.7 46.2 110 CU-02 2010 Control unit with Ethernet port, RS232 and 2 additional serial comms. (232+485) Control unit with Ethernet port, RS232 and Profibus DP slave 45.2 152 20.6 46.2 22 accessories The dimensions are expressed in mm CABLES APS2 CABLECUCONF APS2 CABLECUPROG POWER ADAPTOR 3.2 A POWER ADAPTOR 5 A PLUG WITH 11 polE CLAMP TERMINALS PLUG WITH 14 polE SCREW TERMINALS ACCESSORIES COMBUSTION CONTROL POWER ADAPTORS APS2 ALDR75-24 APS2 ALDR12024 PLUGS APS2 SPINAM11 APS2 SPINAV11 RS232 CABLE 2m, config. CU, PC-DB9F/CU-RJ45 Ethernet CABLE 2m, programm. CU, PC-RJ45/CU-RJ45 SPECIAL CONTROLLERS AND “CUSTOM” 0 1 INPUTS THERMOSTATS ANALOGUE CONTROLLERS Remote I/O cu02 CU-02 5010 Note: SigmaPAC is a programmable distributed controller, modular and open. It is based on a CANOpen network to which are connected the I/O modules. I/O modules: See section “Acquisition and data recording”. CU02 REMOTE SUPERVISOR PREPROGRAMMED SYSTEMS 24 Vdc (-15... +25%) (50/60 Hz) 6.5 VA 152 x 110 mm, depth 66 mm / 430 g circa On OMEGA DIN A rail IP 20 0… +55°C (32… +131°F) / -20…+85°C (-4… +185°F) 5… 95 RH% without condensation Code - 01 - 02 PLC AND OPERATOR PANELS ARM 32 bit 16 MB of RAM system, 128 kB redundant FLASH memory IL, ST, FBD, LD, SFC, CFC IEC61131-3 on board ≥5ms (10ms tipical) 1xEthernet + 1xRS485 (CANOpen) + 1xRS232 + 1xRS232/USB + 1xRS485 Modbus RTU (Master/Slave), Modbus TCP Server, CANOpen Master, Profibus DP, ASCII cpu module - sigma2 Model 01 - spare parts only Model 02 serial communication Not available ProfiBus RS232 + RS485 serial communications RS232 USB Ethernet Available instruction manual Italian / English Not available customization Standard Customized TIMERS COUNTERS POWER LIMITERS functional Processor Memory Programming languages Standard Real time clock Execution cycle Minimum time Serial ports Protocols GENERAL Power supply Power consumption Dimensions / Weight Mounting Front protection degree Operating / storage temperature Operating humidity cu02 To compose the part number, pls. choose one of the option for each variable INDICATORS 1x relay 1A 120Vac/24Vdc resistive load for Watchdog and Wake Up functions Digital COnnections I/O MODULES control unit - sigmapac line - CU02 one input 24Vdc NO contact 69.3 input Digital outputs SUPERVISION how to order features 12.7 •distributed programmable controller •CANOpen + ethernet •2xrs232 e 1xrs485 •1 profibus dp slave port ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS cu02 sigma2 110 111 Programming languages Programming ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS IEC 61131-3 programming software screenshots DIN RAIL MOUNTING CONTROLLERS Software OpenPCS APS2 SWOPCS00 ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS TIMERS COUNTERS POWER LIMITERS PLC AND OPERATOR PANELS Libraries Software OpenPCS IEC 61131-3 Instruction List Structured Text Function Block Diagram Ladder Diagram Sequential Function Chart Continous Function Chart Application project developing structured and simplified by the variable declaration method and keywords auto-recognition. Integrated online debug and simulation tools. Projects management “easy to use” trough the dedicated browser. AT_Generic_Advanced_Lib: includes advanced calculation and process functions such as Averages, Characterizations/Linearizations, A/D conversions, A/D Selectors, Totalizators, Limiters AT_Process_Generic_Lib: includes advanced calculation and process functions such as Alarms, Singnal’s conditioning, Dew point, Relative Humidity, Bacteria load reduction (F0), Compensated flow, Carbon potential calculation AT_IO_Modules_Basic_Lib: specifically designed to configure and manage the I/O modules AT_Process_Control_Lib: includes all the advanced PID functions dedicated to the process control such as single or double action controllers, within different Autotuning and Feed Forward modes AT_CU02_Cpu_Lib: specifically designed to manage the whole communication and diagnostic operations of the onboard I/Os and remote modules AT_Communications_Lib: includes a complete set of function blocks dedicated to the Modbus Master, Slave and Profibus agents communication activities plus Modems management. THERMOSTATS ANALOGUE CONTROLLERS functional Standard SPECIAL CONTROLLERS AND “CUSTOM” how to order features PAC SYSTEMS •programming Software compliant to standard IEC 61131-3 •6 programming languages •wide range of libraries to simplify the programming PREPROGRAMMED SYSTEMS openpcs IND U S T R I A L A U T OM AT I O N | PA C S Y S T EM S 112 113 pre-programmed systems Solutions ready to be used! Flexible systems able to suit to all plants, through a simple configuration and programming by means of touch screens. 114 115 INDUSTRIAL CONTROLLERS operator panels CODE THERMOSTATS ANALOGUE CONTROLLERS P SPECIAL CONTROLLERS AND “CUSTOM” P 4 6 8 8 operator panels components PREPROGRAMMED SYSTEMS ClimaPAC The control system climaPAC is able to perform : boiler control in power or temperature the cascade of condensing modules adjustment of 3 independent heating outlets each with temperature curve and weekly programmable thermostat with 8 slots for attenuation adjustment of domestic hot water in the boiler the management of the recirculation circuit with programmable time bands the function against legionella management of solar panels reading counts calories in the central the remote management climaPAC allows to monitor online the system, to examine continuous recording of process data, to work on the operative parameters ( programmable thermostats, curves weather, etc . ) access to facilities and functionality is regulated by password for each plant the interventions carried out by the various operators can be recorded and it is possible to upload electronic documents so that it is always available via the Internet CPS02 Operator panel Without Operator panel With Operator panel integrated in the system Modem Without Modem With UMTS Modem for remote management INPUTS expansion modules Without modules With 4 PT1000 inputs modules (for transfer of solar thermal) With 6 PT1000 inputs modules With 8 PT1000 inputs modules outputs expansion modules Without modules With 8 0… 10V control outputs modules Accessories OPKIT - Kit made of 7” Touch screen operator panel with connection cables R2IA46P015NPSCO - PT1000 6X40 mm probe in ABS case R2IB126P15NPS - PT1000 6X120 mm probe with 1.5 m PVC cable 9TUDRC102 - Thermowell for immersion probes 1/4 gas thread, pipe 7.5x60 mm under-thread 60 mm with PG7 connector PLC AND OPERATOR PANELS FEATURES Functions ADVANCED PROGRAMMER CONTROLLERS To compose the part number, pls. choose one of the option for each variable pre-programmed solution electric panel probes and thermowell m81 hydraulic diagram ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS System elements Electric panel code CPS 02 Kit external operator panel Supervision via Web ClimaVEM PT1000 probe with thermowell and PT1000 probe for external mounting DIN RAIL MOUNTING CONTROLLERS HOW TO ORDER PAC SYSTEMS •“Turn key” solution for boiler rooms •Complete control solution with high connectivity TIMERS COUNTERS POWER LIMITERS clima pac IND U S T R I A L A U T OM AT I O N | P R E -P R O GR A MME D S Y S T EM S 116 117 m81 features Functions BreweryPAC Solution that allows to control the temperature in the fermenter for beer production. Enabling is done through the touch screen and allows both control and supervision of individual fermenters. The modularity of the system is 8. Temperature control of the fermentors Temperature real time trend with time base of 1, 3, 6, 12 hours Daily historical trend Alarm management Alarm history recording Remote Management via Ethernet (also via the Web, via tablet or PC) PRE-PROGRAMMED SOLUTION Operator panel OPMT3105/N Modular solution: 1 to 32 controllers mod. K31 or 1 to 4 M81 controllers (each controlling 8 zones) ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS TIMERS COUNTERS POWER LIMITERS PLC AND OPERATOR PANELS System components ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS components DIN RAIL MOUNTING CONTROLLERS BP01 XXX-YY OPMT3105/N pre-programmed with BreweryPAC interface on board no. 1… 8 Controllers mod. M81 pre-programmed with BreweryPAC applicative no. 1… 32 Controllers mod. K31 THERMOSTATS ANALOGUE CONTROLLERS To compose the part number, pls. choose one of the option for each variable screenshots SPECIAL CONTROLLERS AND “CUSTOM” how to order PAC SYSTEMS •pre-programmed system to manage brewery plants PREPROGRAMMED SYSTEMS brewery pac IND U S T R I A L A U T OM AT I O N | P R E -P R O GR A MME D S Y S T EM S 118 119 INDUSTRIAL CONTROLLERS components FEATURES Functions Electric panel code CPS 03 Electric power panel code LPS 01 operator panels electric panel THERMOSTATS ANALOGUE CONTROLLERS electric panel dimensions SPECIAL CONTROLLERS AND “CUSTOM” What is it ? LightPAC It is a control system to be installed in electrical cabin with optional functionality to handle remote commands with a Point to Point connection from a PC. The control system LightPAC consists of two electric panels : one for the power (LPS 01) and one for the control (CPS 03). The system is able to perform the programming of the load distribution of the lighting three-phase or single phase systems. The control panel is interfaced with the power panels LPS 01 equipped with power controllers TH...E series: these can control single-phase systems or three-phase power up to 60A. Power supply voltage reduced lighting Adjustment of the light depending on times (10 progr. with 6 slots) Measure of the current supplied Calculation of power and energy saving Registration of the average daily savings Remote Management via Ethernet (also via the Web) ADVANCED PROGRAMMER CONTROLLERS •Soluzione di telecontrollo per la ripartizione del carico luci DIN RAIL MOUNTING CONTROLLERS light pac IND U S T R I A L A U T OM AT I O N | P R E -P R O GR A MME D S Y S T EM S ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS TIMERS COUNTERS POWER LIMITERS PLC AND OPERATOR PANELS PREPROGRAMMED SYSTEMS System components PAC SYSTEMS PRE-PROGRAMMED SOLUTION 120 121 plc and operator panels Solutions for every demand of space! PLC and operator panels with bright TFT display widescreen high resolutionre back lighted LED and up to 256 MB of memory. For every application where power and control have to be separate from the HMI, we offer operator panels, both for front panel mounting and with custom dimensions. 122 123 · OPMT 3105/n OPMT 3120 OPMT 3150/N · · · 128 128 262 K · · 128 64 65 K 128 64 66 K 128 64 67 K · · · · · · 256 256 16.7 M · · · · · · 128 64 68 K · · · · · · 128 64 68 K · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 256 256 16.2 M · · · · · · · · · 256 256 262 K · · · · · · · · · · · · · · · · · · P01 78 x 35 on request 12 Vdc 9 Vdc P30 · P32 · · · · · · · · · · · THERMOSTATS ANALOGUE CONTROLLERS · OPMT 8100i SPECIAL CONTROLLERS AND “CUSTOM” OPMT 3070 PAC SYSTEMS 24 Vac/Vdc OPMT 8070iH · · · ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES Single display Double display Power supply (from the controller) TTL Modubus not isolated CE certification + UL approval OPMT 6050iV · · features Dimensions (mm) OPMT 8050i · PREPROGRAMMED SYSTEMS Flash MB memory RAM MB memory Colours Slot SD/SDHC card USB Host USB Client Ethernet Power supply Audio Video COM1 RS232/485 2 4 wires COM2 RS232 COM3 RS232/485 2 wires COM1 RS485 2 wires CAN bus Programming Software (optional) CE certification + UL approval p04 · PLC AND OPERATOR PANELS Dimensions (inches) 4.3" 7" 10" 10.4” 12.1" 15" INDICATORS features TIMERS COUNTERS POWER LIMITERS plc and operator panels DIN RAIL MOUNTING CONTROLLERS ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS IND U S T R I A L aut o m ati o n | pl c and o p e rat o r pane ls 124 125 UL V04 Autoextinguishing plastic 83 x 159 x 28 mm 200 g IP65 0... +50°C (32°... +122°F) /-20... +60°C (-4... +140°F) 10...90% RH without condensation xx e u S L C M c E N B r s w DIN RAIL MOUNTING CONTROLLERS 157 156 80.4 125 The dimensions are expressed in mm 156 156 79.4 THERMOSTATS ANALOGUE CONTROLLERS p 134 SPECIAL CONTROLLERS AND “CUSTOM” 125.5 Code ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS QT programming tool ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS 24 Vdc/Vac ±20% 250 p04 model Touch screen 4.3” operator panel Touch screen 4.3” operator panel with PLC function on board applicative on board Code that defines the applicative ethernet port Not available Ethernet usb port Not available USB com port Not available RS485 AT LIN CAN sd card Not available SD card memory clock Not available Real Time Clock connections Plug-in screw type with connectors included No connectors case - colour and shape Black, rectangular Black, rounded White, rectangular White, rounded PAC SYSTEMS ARM9 26 32 Bits 4545 MHz processor programmable with standard languages IEC61131-3, simulator and application monitor for debugger 4 GB Micro SD 2.0 x 1 10/100 base-T COM1 RS485 2w Modbus RTU, ASCII, TPC, CANOpen Available P04 To compose the part number, pls. choose one of the option for each variable PREPROGRAMMED SYSTEMS 128 128 dimensions PLC AND OPERATOR PANELS p04 4.3” TFT 480 x 272 280 LED 262 K 4 wire Resistive Type 80 DISPLAY Display Resolution (pixel) Brightness (cd/m²) Back Light type Colours Touch panel MEMORy Flash (MB) RAM (MB) functional CPU PLC Slot SD card USB Host Ethernet COM port Fieldbuses RTC power supply Power supply Power consumption (mA @24V) MEChanical Case Dimensions Weight Protection degree Operating temperature / Storage Operating humidity SOFTWARE Graphic interface TIMERS COUNTERS POWER LIMITERS how to order features 80 •plc with Touch screen monitor •TFT widescreen High resolution backlighted LED Display •4.3” 66 p04 IND U S T R I A L aut o m ati o n | pl c and o p e rat o r pane ls 126 127 IND U S T R I A L aut o m ati o n | pl c and o p e rat o r pane ls 350 500 500:1 LED 65 K 16.7 M 4 wire Resistive Type 128 64 128 Available Not available 10/100 T Not available Not available Available Not available COM1 RS232/RS485 2 and 4w, COM3 RS485 2w Not available Not available Available 128 256 256 1.1 x 1 Not available SD/SDHC 2.0 x 1 2.0 x 1 10/100 base-T COM1 RS232/485 2 and 4w, COM3 RS232/RS485 2w Available Available DIN RAIL MOUNTING CONTROLLERS 4.3” TFT, 65K colours, wide screen 16/9, 480x272 p. 4.3”TFT , 65K colours, wide screen 16/9, 480X272 p. 7”TFT, 65K colours, 16/9, 800x480 p. 2xUSB+SD card 7” TFT , 16.7M col., 800x480 p. 2xUSB + SD/SDH card THERMOSTATS ANALOGUE CONTROLLERS 7” TFT 800 x 480 OPMT 8050IE 6050IP 8070IE 3070 SPECIAL CONTROLLERS AND “CUSTOM” 3070 24 Vdc ±20% 250 250 g 350 UL V04 Autoextinguishing plastic 300 g 600 g IP65 0... +50°C / 32°... +122°F 10...90% RH without condensation Programmable with “Easy Builder 8000” software 400 Aluminium 900 g IP66 -20... +50°C / -4°... +122°F Programmable with “Easy Builder Pro” software ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS Software (optional) 8070iE 4.3” TFT 480 x 272 500 COM port Audio CAN bus RTC power supply Power supply Power consumption (mA @24V) MEChanical Case Weight Protection degree Operating temperature Operating humidity SOFTWARE 6050ip PLC AND OPERATOR PANELS Display Resolution (pixel) Brightness (cd/m²) Contrast ratio Back Light type Colours Touch panel MEMORy Flash (MB) RAM (MB) I/O ports Slot SD card USB Host USB Client Ethernet 8050ie TIMERS COUNTERS POWER LIMITERS DISPLAY OPMT PAC SYSTEMS how to order features PREPROGRAMMED SYSTEMS •Touch screen operator panels •TFT widescreen High resolution backlighted LED Display •4.3” and 7” ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS opmt 128 129 IND U S T R I A L aut o m ati o n | pl c and o p e rat o r pane ls 1024 x 768 500 350 700:1 LED 16.2 M 256 256 Not available 1.1 x 1 Not available SD/SDHC 2.0 x 1 2.0 x 1 PAC SYSTEMS 128 128 10/100 base-T COM1 RS232/485 2 and 4w, COM3 RS232/RS485 2w, CAN Bus (CANOpen protocol) Available NTSC/PAL RCAx2 Available COM1 RS232/485 2 and 4w, COM3 RS485 2w Not available 24 Vdc ±20% 400 800 850 UL V04 Autoextinguishing plastic 1.300 g 1.600 g 2.100 g IP65 IP66/NEMA4 0... +50°C / 32°... +122°F 10...90% RH without condensation Programmable with “Easy Builder 8000” software 10” TFT , 65K colours, 800x480 p. 2xUSB + SD card 10.4” TFT , 262K colours, 800x600 p. 2xUSB + SD card 12,1” TFT, 16.2M colours, 1024x768 p. 2xUSB 15” TFT, 16.2M colours, 1024x768 p. 2xUSB SPECIAL CONTROLLERS AND “CUSTOM” 4 wire Resistive Type OPMT 8100I 3105/N 3120 3150/N 900 Aluminium Programmable with “Easy Builder Pro” software 2.750 g IP65 ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES Software (optional) 262K 3150/N 15” TFT PREPROGRAMMED SYSTEMS Audio Video RTC power supply Power supply Power consumption (mA @24V) MEChanical Case Weight Protection degree Operating temperature Operating humidity SOFTWARE 65 K 3120 12.1” TFT PLC AND OPERATOR PANELS COM port 3105/n 10.4” TFT 800 x 600 400 400:1 TIMERS COUNTERS POWER LIMITERS Display Resolution (pixel) Brightness (cd/m²) Contrast ratio Back Light type Colours Touch panel MEMORy Flash (MB) RAM (MB) I/O ports Slot SD card USB Host USB Client Ethernet 8100iE 10” TFT 800 x 480 300 500:1 INDICATORS DISPLAY OPMT DIN RAIL MOUNTING CONTROLLERS how to order features THERMOSTATS ANALOGUE CONTROLLERS •Touch screen operator panels •TFT widescreen High resolution backlighted LED Display •10”, 10.4”, 12.1” and 15” ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS opmt 130 131 IND U S T R I A L aut o m ati o n | pl c and o p e rat o r pane ls 12 Vdc supplied by the controller Internal buzzer (optional) TTL Modubus not isolated ModBus-RTU (JBUS) 38400 baud 9 Vdc supplied by the controller 50 mA On request / 115 g approx. 78 x 35 mm - depth 64 mm / 120 g approx. Behind layout Flush in panel in 71 x 29 mm hole -IP65, mounted on panel with gasket Screw terminals Screw terminal block 2.5 mm² 0... 50°C (32… 122°F) / -20… 70°C (-4… 158°F) 20… 95 RH% without condensation Directive EMC 2004/108/CE (EN 61326) - Directive LV 2006/95/CE (EN 61010-1) Code P30 / P32 Display Red Blue Buzzer (internal) Available Not available Code K30 1 5 2 4 - 3 3 W - 4 2 5 1 A U p32 U B - P30 K30 1 5 2 4 3 3 4 2 5 1 P32 dimensions INDICATORS p30 / p32 6 12.2 28 35 78 SUPERVISION 64 35 78 DIN RAIL MOUNTING CONTROLLERS P01 Display Red Amber Blue Input From the connected controller Output Out 8 Vdc Not available THERMOSTATS ANALOGUE CONTROLLERS 500 ms -- p30 To compose the part number, pls. choose one of the option for each variable SPECIAL CONTROLLERS AND “CUSTOM” P32 Dual: Main: 4 red digit, h 7 mm Secondary: 4 red digit, h 7 mm PAC SYSTEMS FUNctional Sampling rate Acoustic alarm Serial communication Protocol Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Front protection degree Connections Operating / storage temperature Operating humidity Conformity P30 Single: 4 red digit, h 12 mm + Bargraph 3 LED PREPROGRAMMED SYSTEMS Display P01 Single: 4 red digit, h 15.5 mm + Bargraph 3 LED TIMERS COUNTERS POWER LIMITERS DISPLAY COnnections PLC AND OPERATOR PANELS how to order features I/O MODULES •remote operator panels •external power supply (by a separated control unit) •78 x 35 mm or on request ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS p 01/30/32 ACCESSORIES COMBUSTION CONTROL The dimensions are expressed in mm 132 133 timers - counters power limiters Multi-scale and multi-function Microprocessor based timers, counters and power limiters with 4 digits single display, equipped with double outputs and screw terminal block. Some models are also available with buffer battery for time counting also in lack of supply. 134 135 4 digit single display 6 digit single display Input TT73 TC34 · · Counters TC49 power limiters TC73 TP34 · · · TP49 · · · · · · · · · · · · · 2 · · 2 · · 2 · · 2 · · 2 · · 2 · · 2 · · 2 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 2 for free voltage contacts 2 for voltage contacts Relay or voltage for SSR drive outputs Relay outputs Power supply TT49 2 12 Vac/Vdc 24 Vac/Vdc 100… 240 Vac · · · · · · · ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS TIMERS COUNTERS POWER LIMITERS PLC AND OPERATOR PANELS Multi-scale, Multi-function Multi-frequency, Multi-function 40 daily and/or weekly programs Manual output driving, Daylight saving time function, Random function CE certification THERMOSTATS ANALOGUE CONTROLLERS 78 x 35 48 x 48 72 x 72 70 x 84 4 DIN Modules TT34 · SPECIAL CONTROLLERS AND “CUSTOM” Dimensions (mm) BWT40 PAC SYSTEMS Timers FEATURES PREPROGRAMMED SYSTEMS timers - counters - power limiters DIN RAIL MOUNTING CONTROLLERS ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS industrial A U T OM Ati o n | time rs - c o unt e rs - p o w e r limit e rs 136 137 Up to 2 FUNCTIONAL Programmable functions GENERAL Power supply Power consumption Battery Accuracy Dimensions / Weight Mounting Operating / storage temperature Operating humidity Pulses programming: adjustable from 0 to 59 sec Manual outputs driving Daylight Saving Time Random Function 40 daily/weekly programs LED for status indication of the relay outputs LED indication of the instrument powered 100... 240 Vac ±10% (48...63 Hz) 4.4 VA approx. Internal 4 years approx. (at 20 ° C): ± 2.0 35.8 x 90 mm, depth 73 mm / 110 g approx. On OMEGA DIN A rail 0... 50°C (32… 122°F) / -20… 70°C (-4… 158°F) 30...95% RH without condensation bwt40 To compose the part number, pls. choose one of the option for each variable BWT40 Power supply 100… 240 Vac/Vdc OUT 1 Relay OUT 2 Relay Not available ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS OUT 1: Relay SPDT 16 A at 250 VCA or OUT 1 and OUT 2: Relay SPDT 8 A at 250 VCA CONNECTIONS DIN RAIL MOUNTING CONTROLLERS BWT40 Multi-indication, 6 digit CODE BWT40HR H R R - 7 8 BWT40HRR 9 10 11 12 7 8 9 10 11 12 Uscita 1 Uscita 1 Relè 16A@250Vca, cosϕ = 1 2 relè 8A@250Vca, cosϕ = 1 Alimentazione 100... 240Vca Alimentazione 100... 240Vca 1 2 3 4 5 6 1 2 Uscita 2 3 4 5 6 DIMENSIONS bwt40 49 73 34.3 68 ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS The dimensions are expressed in mm TIMERS COUNTERS POWER LIMITERS 90 PLC AND OPERATOR PANELS 35.8 THERMOSTATS ANALOGUE CONTROLLERS DISPLAY Single LCD OUTPUTS SPECIAL CONTROLLERS AND “CUSTOM” how to order FEATURES PAC SYSTEMS •multifunction timer programmer •Up to 2 OUTPUTS •Up to 40 daily and weekly programs PREPROGRAMMED SYSTEMS BWt40 industrial A U T OM Ati o n | time rs - c o unt e rs - p o w e r limit e rs 138 139 industrial A U T OM Ati o n | time rs - c o unt e rs - p o w e r limit e rs 12 Vac/Vdc, 24 Vac/Vdc, 90… 240 Vac/Vdc ±10% (50/60 Hz) 2 VA approx. 9 mA approx. 4.5 mA approx. External 9 V - E type Internal 3.6 V - rechargeable 1 mA max. 48 x 48 mm (1/16DIN) 72 x 72 mm - depth 96 mm / depth 98 mm / 200 g approx. 270 g approx. Screw terminal block 2x1 mm² Flush in panel in 29 x 71 mm hole Flush in panel in 45 x 45 mm hole Flush in panel in 66.5 x 66.5 mm hole IP 65, mounted on panel with gasket IP 54, mounted on panel with gasket 0... 50°C (32… 122°F) / -20… 70°C (-4… 158°F) 30… 95 RH% without condensation Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1) 33 x 75 mm - depth 64 mm / 175 g approx. THERMOSTATS ANALOGUE CONTROLLERS F H L SPECIAL CONTROLLERS AND “CUSTOM” V C RR OO B - tt49 DIMENSIONS tt34 6 78 12.2 64 78 tt73 The dimensions are expressed in mm 9.5 48 INDICATORS tt49 Note: The external battery (9V - type E) is provided only on request. The battery is used to keep counting even in the absence of supply. 98 SET Out1 Out2 - = + I/O MODULES 44.5 48 AT ST Out3 Out4 The dimensions are expressed in mm tt73 9 COMBUSTION CONTROL 8 72 Out1 Out2 - = 55 72 SET 65.5 AT ST + 88 140 PAC SYSTEMS OUT 1: Delayed, Feedthough, oscillator (start/stop) with asymmetric times start ON, or start OFF, One cicle asymmetric oscillator (start/stop) with start OFF, OUT 2: as OUT 1, as instant contact, as OUT 1 but with another independent time, as OUT 1 but with another relative time 9999 hrs - 99 hrs 59 min - 99 min 59 sec - 99 sec 99 cent. sec UP or DOWN According to the used scale : hrs - min - sec - Cent sec According to the used ext. battery Approx. 10 hrs with full load battery tt34 CODE PREPROGRAMMED SYSTEMS OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or 12 Vdc/15 mA to drive SSR TT34 / TT49 / TT73 Power supply 12 Vac/Vdc 100… 240 Vac/Vdc 24 Vac/Vdc INPUT Voltage Free voltage OUT 1 + OUT 2 Relay Vdc for SSR driving Battery (TT49 and tt73 only) Internal External - 9V Type E PLC AND OPERATOR PANELS 2 for free voltage contacts or 2 for voltage contacts (the same of the power supply) 15 msec max. To compose the part number, pls. choose one of the option for each variable TIMERS COUNTERS POWER LIMITERS Connections Mounting Front protection degree Operating / storage temperature Operating humidity Conformity 4 red digit, h 12 mm CONNECTIONS SUPERVISION Dimensions / Weight TT73 4 red digit, h 14 mm 28 Programmable time scales Counting mode Display resolution Counting autonomy without power supply GENERAL Power supply Power consumption Power consumption with battery supply Battery Power consumption voltage inputs TT49 35 Programmable functions TT34 35 DISPLAY Single INPUTS Digital inputs Delay time inputs OUTPUTS Up to 2 FUNCTIONAL DIN RAIL MOUNTING CONTROLLERS how to order FEATURES The dimensions are expressed in mm ACCESSORIES •Multiscale and Multifunction Timers •Up to 2 OUTPUTS •with back up battery ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS tt 34/49/73 141 industrial A U T OM Ati o n | time rs - c o unt e rs - p o w e r limit e rs how to order 12 Vac/Vdc, 24 Vac/Vdc, 90… 240 Vac/Vdc ±10% (50/60 Hz) 3 VA approx. 1 mA max. 33 x 75 mm - depth 64 mm / 48 x 48 mm (1/16DIN) 72 x 72 mm - depth 96 mm / 175 g approx. depth 98 mm / 200 g approx. 270 g approx. Screw terminal block 2x1 mm² Flush in panel in 29 x 71 mm hole Flush in panel in 45 x 45 mm hole Flush in panel in 66.5 x 66.5 mm hole IP 65, mounted on panel with gasket IP 54, mounted on panel with gasket 0... 50°C (32… 122°F)/-20… 70°C (-4… 158°F) 30… 95 RH% without condensation Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1) tc34 CODE THERMOSTATS ANALOGUE CONTROLLERS F H L V C SPECIAL CONTROLLERS AND “CUSTOM” Restart - Restart/Lap - Count 2 - 10 - 40 - 125 - 1000 Hz. Programmable UP or DOWN 9999 Programmable Back-up function in case of power supply failure TC34 / TC49 / TC73 Power supply 12 Vac/Vdc 100… 240 Vac/Vdc 24 Vac/Vdc INPUT Voltage Free voltage OUT 1 + OUT 2 Relay Vdc for SSR driving RR OO DIMENSIONS tc49 tc34 6 78 12.2 64 78 The dimensions are expressed in mm tc49 9.5 98 44.5 48 AT ST SET = + Out3 Out4 I/O MODULES - tc73 INDICATORS 48 Out1 Out2 PAC SYSTEMS OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or 12 Vdc/15 mA to drive SSR To compose the part number, pls. choose one of the option for each variable PREPROGRAMMED SYSTEMS 2 for free voltage contacts or 2 for voltage contacts (the same of the power supply) 15 msec max. CONNECTIONS PLC AND OPERATOR PANELS 4 red digit, h 12 mm TC73 4 red digit, h 14 mm 35 Connections Mounting Front protection degree Operating / storage temperature Operating humidity Conformity TC49 TIMERS COUNTERS POWER LIMITERS Dimensions / Weight TC34 28 DISPLAY Single INPUTS Digital inputs Delay time inputs OUTPUTS Up to 2 FUNCTIONAL Programmable functions Frequenza di conteggio Counting mode Display resolution Back up memory GENERAL Power supply Power consumption Power consumption voltage inputs 35 FEATURES DIN RAIL MOUNTING CONTROLLERS •multifunction and multifrequency Counters •Up to 2 OUTPUTS ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS tc 34/49/73 The dimensions are expressed in mm Out1 Out2 - = 55 72 SET 65.5 AT ST + 88 The dimensions are expressed in mm 142 COMBUSTION CONTROL 9 ACCESSORIES 8 72 SUPERVISION tc73 143 12 Vac/Vdc, 24 Vac/Vdc, 90… 240 Vac/Vdc ±10% / 50/60 Hz 2 VA approx. 1 mA max. Asymmetric oscillator timer (start/stop) with power limiter function OUT 1: oscillator (start/stop) with asymmetric times start ON, or start OFF OUT 2: as OUT 1, as OUT 1 but in opposite way, as OUT 1 but in opposite way with power limiter function From 1 to 900 sec 33 x 75 mm - depth 64 mm / 175 g approx. 48 x 48 mm (1/16DIN) - depth 98 mm/ 200 g approx. Screw terminal block 2x1 mm² Flush in panel in 29 x 71 mm hole Flush in panel in 45 x 45 mm hole IP 65, mounted on panel with gasket IP 54, mounted on panel with gasket 0... 50°C (32… 122°F)/-20… 70°C (-4… 158°F) 30… 95 RH% without condensation Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1) tp34 CODE F H L V C R O R O DIMENSIONS TP34 6 78 12.2 28 64 35 78 The dimensions are expressed in mm ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or 12 Vdc/15 mA to drive SSR TP34 / TP49 Power supply 12 VacV/DC 100… 240 Vac/Vdc 24 Vac/Vdc INPUT Voltage Free voltage OUT 1 Relay VdcxSSR OUT 2 Relay Vdc for SSR driving THERMOSTATS ANALOGUE CONTROLLERS 2 for free voltage contacts or 2 for voltage contacts (the same of the power supply) 15 msec max. To compose the part number, pls. choose one of the option for each variable SPECIAL CONTROLLERS AND “CUSTOM” 4 red digit, h 12 mm CONNECTIONS 35 Outputs cycle time Dimensions / Weight Connections Mounting Front protection degree Operating / storage temperature Operating humidity Conformity TP49 tp49 PAC SYSTEMS Programmable functions TP34 PREPROGRAMMED SYSTEMS DISPLAY Single INPUTS Digital inputs Delay time inputs OUTPUTS Up to 2 GENERAL Power supply Power consumption Power consumption voltage inputs FUNCTIONAL Application PLC AND OPERATOR PANELS how to order FEATURES DIN RAIL MOUNTING CONTROLLERS •Limitatori di potenza •Up to 2 OUTPUTS TIMERS COUNTERS POWER LIMITERS tp 34/49 industrial A U T OM Ati o n | time rs - c o unt e rs - p o w e r limit e rs SET Out1 Out2 - = + 44.5 48 AT ST Out3 Out4 ACCESSORIES COMBUSTION CONTROL The dimensions are expressed in mm I/O MODULES 98 SUPERVISION 9.5 48 INDICATORS TP49 144 145 indicators Much more than simple indicators! Digital indicators with one or more universal inputs and potentiometer or with configurable input. Also available with a dedicated input version strain gauge for melt pressure transducer and load cell. 146 147 indicators Auxiliary input Relay or voltage for SSR drive outputs Analogue current or voltage outputs Measuring retransmission Power supply J1 J3 J5 · · · · · · · · · · 3 · 3 · · · · · · · · · · · · · · · · · · 2 2 · 2 4 3 · · · 2 3 3 2 1 · 4 1 4 1 · 4 1 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · THERMOSTATS ANALOGUE CONTROLLERS · SPECIAL CONTROLLERS AND “CUSTOM” · ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS RS485 ModBus Mathematical Functions MIN, MAX, HOLD PV, HOLD PICCO, MEDIA functions CE certification + UL approval C1 · 4 1 12 Vac/Vdc 20… 30 Vac/Vdc 24 Vac/Vdc 100… 240 Vac K85V PAC SYSTEMS Manin input K48V · · · universal input J-K-S-R-T + IR + PTC-NTC J-K-S-R-T + IR + Pt100 0/4… 20 mA o 0/1… 5 V o 0… 10V Δ T PT100 Digital Strain gauge (5V/10V) 0/4… 20 mA or 0/1… 5 V or 0… 10V K38V · PREPROGRAMMED SYSTEMS 4 digit single display 5 digit single display K31V · PLC AND OPERATOR PANELS Dimensions (mm) TLI40 78 x 35 24 x 48 48 x 48 70 x 84 4 DIN Modules 96 x 48 TIMERS COUNTERS POWER LIMITERS FEATURES DIN RAIL MOUNTING CONTROLLERS ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS IND U S T R I A L aut o m ati o n | indi c at o rs 148 149 Auxiliary power supply 12 Vdc/20 mA max 2.5 Vdc/2.5 mA for Linear Potentiometers FUNCTIONAL Sampling rate Resolution Accuracy Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Connections Mounting Front protection degree Operating / storage temperature Operating humidity Conformity Selectable from 8 to 64 samples per second for analogue signals or potentiometer inputs 8 samples/sec = 32000 points 16 samples/sec = 16000 points 32 samples/sec = 8000 points 64 samples/sec = 4000 points ±0,15% fs RS485 with ModBus-RTU (JBUS) protocol 1200… 38400 baud, programmable 24 Vac/Vdc, 100… 240 Vac ±10% / 50/60 Hz 8 VA approx. 48 x 48 mm - depth 98 mm / 190 g approx. Screw terminal block 2 x 1 mm² Flush in panel in 45 x 45 mm hole IP 54 , mounted on panel with gasket 0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F) 30… 95 RH% without condensation Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1) CONNECTIONS R O C V R O R O - tc J tc K tc S tc B tc E tc L tc N tc R tc T tc C R O - IR sensors (ZIS) Pt100 (IEC) S I - PTC (KTY81-121) B A 0... 20 mA -1999 ... 9999 4... 20 mA -1999 ... 9999 0... 50 mV -1999 ... 9999 0... 60 mV -1999 ... 9999 12... 60 mV -1999 ... 9999 0... 5 V -1999 ... 9999 1... 5 V -1999 ... 9999 0... 10 V -1999 ... 9999 2... 10 V -1999 ... 9999 Potentiometers (> 1 KΩ) -1999 ... 9999 -P -- NTC (103-AT2) -160.0 ... 999.9 °C -199.9 ... 999.9 °F -199.9 ... 999.9 °C -199.9 ... 999.9 °F -50.0 ... 999.9 °C -58.0 ... 999.9 °F 72.0 ... 999.9 °C 162.0 ... 999.9 °F -150.0 ... 999.9 °C -199.9 ... 999.9 °F -150.0 ... 900.0 °C -199.9 ... 999.9 °F -199.9 ... 999.9 °C -199.9 ... 999.9 °F -50.0 ... 999.9 °C -58.0 ... 999.9 °F -199.9 ... 400.0 °C -199.9 ... 752.0 °F 0.0 ... 999.9 °C 32.0 ... 999.9 °F -46.0 ... 785.0 °C -50.8 ... 999.9 °F -99.9 ... 850.0 °C -99.9 ... 999.9 °F -55.0 ... 150.0 °C -67.0 ...302.0 °F -50.0 ... 110.0 °C -58.0 ... 230.0 °F -199.9 ... 999.9 -19.99 ... 99.99 -199.9 ... 999.9 -19.99 ... 99.99 -1.999 … 9.999 -199.9 ... 999.9 -19.99 ... 99.99 -1.999 … 9.999 -199.9 ... 999.9 -19.99 ... 99.99 -1.999 … 9.999 -199.9 ... 999.9 -19.99 ... 99.99 -1.999 … 9.999 -199.9 ... 999.9 -19.99 ... 99.99 -1.999 … 9.999 -199.9 ... 999.9 -19.99 ... 99.99 -1.999 … 9.999 -199.9 ... 999.9 -19.99 ... 99.99 -1.999 … 9.999 -199.9 ... 999.9 -19.99 ... 99.99 -1.999 … 9.999 -199.9 ... 999.9 -19.99 ... 99.99 -1.999 … 9.999 DIN RAIL MOUNTING CONTROLLERS with “dP”= 1, 2, 3 ACCESSORIES tli40 L H without “dP” (decimal point) -160 ... 1000 °C - 256 ... 1832 °F -270 ... 1370 °C - 454 ... 2498 °F -50 ... 1760 °C -58 ... 3200 °F 72 ... 1820 °C 162 ... 3308 °F -150 ... 750 °C -252 ... 1382 °F -150 ... 900 °C -252 ... 1652 °F -270 ... 1300 °C -454 ... 2372 °F -50 ... 1760 °C -58 ... 3200 °F -270 ... 400 °C -454 ... 752 °F 0 ... 2320 °C 32 ... 4208 °F -46 ... 785 °C -50 ... 1445 °F -200 ... 850 °C -328 ... 1562 °F -55 ... 150 °C -67 ... 302 °F -50 ... 110 °C -58 ... 230 °F THERMOSTATS ANALOGUE CONTROLLERS INPUT CODE ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS OUT 1: 0/4…20mA or 0/2…10V TLI40 Power supply 20… 30 Vac/Vdc 90… 240 Vac OUT 1 Relay 20 mA/14 Vdc for SSR driving 0/4… 20mA 0/2… 10V Not available OUT 2 Relay Vdc for SSR driving Not available OUT 3 Relay Vdc for SSR driving Not available OUT 4 Relay Vdc for SSR driving Not available Serial communication AND DIGITAL INPUT RS485 RS485 + Digital input Not available sensor Power supply 2.5 Vdc 12 Vdc for analogue input INPUT FROM potenTIOMETER Available Not available SPECIAL CONTROLLERS AND “CUSTOM” Current or voltage (as aternative to OUT 1) TEMPERATURE ranges PAC SYSTEMS OUT 1, OUT 2, OUT 3 and OUT 4: Relay SPST-NO (5A-AC1, 2A-AC3/250 Vac) or 7mA/14 Vdc to drive SSR To compose the part number, pls. choose one of the option for each variable PREPROGRAMMED SYSTEMS Up to 4 TEMPERATURE RANGEs PLC AND OPERATOR PANELS Accuracy OUTPUTS Thermocouples J, K, S, B, C, E, L, N, R, T and Infrared sensors J or K + Thermoresistances Pt 100 3 wires + Thermistors PTC KTY 81-121 (990 Ω a 25°C) e Thermistors NTC 103AT-2 (10 kΩ a 25°C) + Linear signals 0… 50mV, 0… 60mV, 12… 60mV, 0/4... 20mA, 0/1… 5V, 0/2…10V + Linear Potentiometers (see next page for temperature ranges) ±0.15% fs HOW TO ORDER TIMERS COUNTERS POWER LIMITERS Universal TLI40 4 red digit, h 12 mm INDICATORS DISPLAY Single INPUTS I/O MODULES FEATURES SUPERVISION •universal and potentiometer input •Up to 4 OUTPUTS •rs485 COMBUSTION CONTROL tli40 IND U S T R I A L aut o m ati o n | indi c at o rs 150 151 Auxiliary power supply FUNCTIONAL Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Connections Set Point RS485 with ModBus-RTU (JBUS) protocol 1200… 38400 baud, programmable -TTL ModBus -- 12 Vac/Vdc, 24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz) 6 VA approx. 78 x 35 mm - depth 64 mm 78 x 35 mm - depth 64 mm / 180 g approx. or 78.5 mm with plug-in terminals / 180 g approx. Plug-in terminals or Screw terminal block 2 x 1 mm² Screw terminal block 2 x 1 mm² Flush in panel in 71 x 29 mm hole IP 65, mounted on panel with gasket 0… 50°C (32… 122°F)/-30… 70°C (-22… 158°F) 20… 85 RH% without condensation Direttive EMC 2004/108/CE (EN 61326-1), Direttive BT 2006/95/CE (EN 61010-1) K38V pOWER SUPPLY 12 Vac/Vdc 24 Vac/Vdc 100… 240 Vac/Vdc input TC,PT100,mV TC,PTC,NTC,mV 0/4… 20mA 0… 1V, 0/1… 5V, 0/2… 10V OUT 1 Relay SPDT 8A-AC1 Vdc for SSR driving OUT 2 Relay SPDT 8A-AC1 Vdc for SSR driving Not available Code DIN RAIL MOUNTING CONTROLLERS k38v THERMOSTATS ANALOGUE CONTROLLERS SPECIAL CONTROLLERS AND “CUSTOM” R O R O R O R O S - DIMENSIONS k31v / k38v F L H C E I V R O R O - 78 6 12.2 78 64 The dimensions are expressed in mm ACCESSORIES Mounting Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) OUT 1 and OUT 2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) or 12V ±20% 20 mA max. to drive SSR or 12V ±20% 20 mA max. to drive SSR OUT 3 and OUT 4: Relay SPST-NO (5A-AC1, 3A-AC3/250 Vac) or 12V ±20% 20 mA max. to drive SSR 12 Vdc/20 mA max. C E I V PAC SYSTEMS Up to 4 (K31V) Up to 2 (K38V) F L H PREPROGRAMMED SYSTEMS Digital inputs OUTPUTS Code PLC AND OPERATOR PANELS 4 different configurations Thermocouples J (0... 1000°C/32... 1832°F), K (0… 1370°C/32... 2498°F), S,R (0… 1760°C/32... 3200°F), T (0... 400°C/32… 752°F) e Infrared sensors J or K + Thermoresistances Pt 100 3 wires (-200.. 850°C/-328... 1562°F) Thermocouples: J (0... 1000°C / 32... 1832°F), K (0… 1370°C / 32... 2498°F), S,R (0… 1760°C / 32... 3200°F), T (0... 400°C / 32… 752°F) and Infrared sensors J or K + Thermistors: PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C / -67... 302°F) and Thermistors: NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C / -58... 230°F) Linear signals 0/4… 20mA Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V 2 for free voltage contacts -- k31v K31V pOWER SUPPLY 12 Vac/Vdc 24 Vac/Vdc 100… 240 Vac/Vdc input TC,PT100,mV TC,PTC,NTC,mV 0/4… 20mA 0… 1V, 0/1… 5V, 0/2… 10V OUT 1 Relay SPDT 8A-AC1 Vdc for SSR driving OUT 2 Relay SPDT 8A-AC1 Vdc for SSR driving Not available OUT 3 Relay SPST-NO 5A-AC1 Vdc for SSR driving Not available OUT 4 Relay SPST-NO 5A-AC1 Vdc for SSR driving Not available serial communication RS485 TTL ModBus TIMERS COUNTERS POWER LIMITERS INPUTS To compose the part number, pls. choose one of the option for each variable INDICATORS 4 red digit, h 12 mm + 3 LEDs Bargraph CONNECTIONS I/O MODULES Single K38V SUPERVISION K31V 28 DISPLAY COMBUSTION CONTROL HOW TO ORDER FEATURES 35 •programmable Indicators •Up to 4 OUTPUTS for alarms management •Serial communication RS485 or ttl ModBus ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS 31v/38v 35 k IND U S T R I A L aut o m ati o n | indi c at o rs 152 153 IND U S T R I A L aut o m ati o n | indi c at o rs Up to 3 Auxiliary supply FUNctional Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions Weight Connections Mounting Front protection degree Operating / storage temperature Operating humidity Conformity OUT1 and OUT2: Relay SPDT (8A-AC1, 3A-AC3/250 Vac) OUT1 and OUT2: Relay SPST-NO (8A-AC1, 3A-AC3/250 Vac) or 12V ± 20% 20 mA max. for SSR driving or 12V ± 20% 20 mA max. for SSR driving OUT3: Relay SPST-NO (5A-AC1, 3A-AC3/250 Vac) OUT3: Relay SPST-NO (5A-AC1, 3A-AC3/250 Vac) or 12V ± 20% 20 mA max. for SSR driving or 12V ± 20% 20 mA max. for SSR driving 12 Vdc/20 mA max. -TTL ModBus -- Set point RS485 with Modbus RTU protocol 1200… 38400 baud, programmable 24 Vac/Vdc, 100… 240 Vac/Vdc ± 10% (50/60 Hz) 6 VA approx. 48 x 48 mm (1/16 DIN) - depth 98 mm 4 DIN rail modules, 70 x 84 mm - depth 60 mm 180 g approx. 230 g approx. Screw terminal block 2.5 mm² Flush in panel in 45 x 45 mm hole On OMEGA DIN A rail IP65, mounted in panel with gasket IP 40, for internal use 0… 50°C (32… 122°F)/-30… 70°C (-22… 158°F) 30… 95 RH% without condensation Directive EMC 2004/108/CE (EN 61326-1), Directive BT 2006/95/CE (EN 61010-1) C E I V R O R O D R O - k48v 9.5 48 98 44.5 48 AT ST SET - = + THERMOSTATS ANALOGUE CONTROLLERS F L H DIMENSIONS Out1 Out2 k48v code DIN RAIL MOUNTING CONTROLLERS K48V / K85V pOWER SUPPLY 12 Vac/Vdc 24 Vac/Vdc 100… 240 Vac/Vdc input TC,PT100,mV TC,PTC,NTC,mV 0/4… 20mA 0… 1V, 0/1… 5V, 0/2… 10V OUT 1 Relay SPDT 8A-AC1 Vdc for SSR driving OUT 2 Relay SPDT 8A-AC1 Vdc for SSR driving Not available OUT 3 2 digital inputs (K48V only) Relay Vdc for SSR driving Not available SPECIAL CONTROLLERS AND “CUSTOM” OUTPUTS To compose the part number, pls. choose one of the option for each variable k85v PAC SYSTEMS Thermocouples (0... 1000°C/32... 1832°F), K (0… 1370°C/32... 2498°F), S,R (0… 1760°C/32... 3200°F), T (0... 400°C/32… 752°F) and Infrared sensors J or K type + Thermoresistances Pt 100 3 wires (-200.. 850°C/-328... 1562°F) Thermocouples J (0... 1000°C/32... 1832°F), K (0… 1370°C/32... 2498°F), S,R (0… 1760°C/32... 3200°F), T (0... 400°C/32… 752°F) and Infrared sensors J or K type + Thermistors PTC KTY 81-121 (990Ω at 25°C) (-55... 150°C/-67... 302°F) and Thermistors NTC 103AT-2 (10kΩ at 25°C) (-50... 110°C/-58... 230°F) Linear signals 0/4… 20mA Linear signals 0/10… 50mV, 0/12… 60mV, 0/1… 5V, 0/2… 10V 2 digital inputs for free voltage contacts, 2 digital inputs for free voltage contacts as alternative to Out 3 CONNECTIONS PLC AND OPERATOR PANELS Digital inputs K85V 4 red digit, h 12 mm + 3 LEDs bargraph TIMERS COUNTERS POWER LIMITERS 4 different configurations K48V 4 red digit, h 7mm INDICATORS DISPLAY Single INPUTS PREPROGRAMMED SYSTEMS HOW TO ORDER features Out3 Out4 The dimensions are expressed in mm I/O MODULES •indicators •up to 3 outputs for alarm indication •RS485 or ttl serial communication ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS K 48V/85V 27 6 7 21 12 8 9 10 11 12 - = + 60 84 Prg Out1 Out2 45 Tun Out3 13 14 15 16 17 18 19 20 21 22 23 24 The dimensions are expressed in mm 154 COMBUSTION CONTROL 4 5 ACCESSORIES 70 1 2 3 SUPERVISION k85v 155 IND U S T R I A L aut o m ati o n | indi c at o rs INDUSTRIAL CONTROLLERS J1 / j3 Special functions Update measurement time Sampling rate Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity Quick Setup using numerical code, “ISA A” Alarm acknowledge sequence, Displaying IN1, IN2, CIN (conditioned input), Displaying max. and min. values, Display locked / timed, Peaks and valleys, Dedicated key for alarms recognition, Sensor break, Alarms acknowledgement (latching), Inhibition at power-on, OR function Quick Setup using numerical code, “ISA A” Alarm acknowledge sequence, Displaying max. and min. values, Display locked / timed, Peaks and valleys, Dedicated key for alarms recognition, Sensor break, Alarms acknowledgement (latching), Inhibition at power-on, OR function 0.7 sec 1.5 sec -- Measurement RS485 with Modbus RTU protocol 1200, 2400, 4800, 9600 baud 100...240Vac (-15...+10%) or 24Vac (-25...+12%) or 24Vdc (-15...+25%) (50/60 Hz) 5 VA approx. 96 x 48 mm (1/8 DIN), depth 110 mm / 250 g approx. Flush in panel in 92 x 45 mm hole Screw terminal block M3 for cables with section 1 mm² (18AWG) IP65 0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F) 5… 95% RH without condensation EN61010-1 (IEC1010-1) DIN RAIL MOUNTING CONTROLLERS CODE 0 1 7 9 Thermocouple 0 5 mV Pt100 External shunt 2.5Ω mA 0 1 2 5 j3 0 V 0 9 0 2 Thermocouple NA Pt100 mV NPN 0 3 mA Rj mA V mA TTL SPECIAL CONTROLLERS AND “CUSTOM” THERMOSTATS ANALOGUE CONTROLLERS 3 5 PAC SYSTEMS OUT 1: Relay SPDT 2A/250Vac (4A/120Vac) for resistive loads OUT 2 and OUT 3: Relay NO 2A/250Vac (4A/120Vac) for resistive loads OUT 1: Relay SPDT 2A/250Vac (4A/120Vac) for resistive loads OUT 4: Logic not isolated 0/5 Vdc ±10% 30mA max. OUT 2: Relay NO 2A/250Vac (4A/120Vac) for resistive loads or Relay NO, 2A/250Vac (4A/120Vac) for resistive loads OUT 5: 0/4...20 mA for inputs retransmission 24 Vdc (±20%)/30 mA max. for external transmitter 2, programmable as alarm 4, programmable as alarm J1/J3 Power supply 100… 240 Vac 24 Vac/Vdc OUT 1, out 2, out 3 and out 4 Not available Relay-Relay-Relay-SSR (J3 only) Relay-Relay Relé-relé-relé-relé (J3 only) Serial communication Not available RS485 SPECIAL FUNCTIONS Not available OUT 5 retransmission (J3 only) Input IN2 (J3 only) OUT 5 retransmission + IN2 (Solo J3) SPECIAL FUNCTIONS Not available INSTRUCTION MANUAL Italian/English Not available FRONT FRAME COLOUR Dark grey (std) Dark grey shunt 0.1% SPECIAL EXECUTION Not available Conformal coating PREPROGRAMMED SYSTEMS Auxiliary power supply Outputs configuaration FUNCTIONAL Thermocouples: L/J (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F), K (0…+1200°C / 32…+2192°F), S/R (0... +1600°C / 32...2912°F) B (0... +1800°C / 32... 3272°F), N (0... +1200°C / 32... 2192°F), E (0... +600°C / 32... +1112°F), Ni-NiMo (0... +1100°C / 32... +2012°F), W3/W5 (0... +2000°C / 32... 3632°F) Thermoresistances: PT100 (-200... +600°C / -328... +1112°F) Linear signals: 0/10... 50 mV; 0/4…20 mA (shunt) Infrared sensors or special ranges (custom) -0/4...20 mA o 0/1...5 V, 0...10 V 3, logic type not isolated 0.25% ±1 digit (thermoelements) or 0.1% ±1 digit (for mA and mV) j1 To compose the part number, pls. choose one of the option for each variable PLC AND OPERATOR PANELS Up to 2 (J1) Up to 5 (J3) 5 digit programmable as red or green, h 15.5 mm CONNECTIONS External shunt 2.5Ω TIMERS COUNTERS POWER LIMITERS Auxiliary input (IN2) Digital inputs Accuracy OUTPUTS J3 DIMENSIONS j1 / j3 INDICATORS Main input (IN1) J1 110 96 I/O MODULES DISPLAY Single INPUTS 48 10 max. SUPERVISION HOW TO ORDER FEATURES ADVANCED PROGRAMMER CONTROLLERS •J1: 5 digit Indicator with 2 alarms •J3: 5 digit Indicator with 2 INPUTS and 4 alarms ACCESSORIES COMBUSTION CONTROL The dimensions are expressed in mm 156 157 Special functions INDUSTRIAL CONTROLLERS Quick Setup using numerical code, “ISA A” Alarm acknowledge sequence, Displaying IN1, IN2, CIN (conditioned input), Displaying max. and min. values, Display locked / timed, Peaks and valleys, Dedicated key for alarms recognition, Sensor break, Alarms acknowledgement (latching), Inhibition at power-on, OR function 20 ms 0.5 sec Measurement RS485 with Modbus RTU protocol 1200, 2400, 4800, 9600, 19200, 36400, 56800 baud 100...240Vac (-15...+10%) or 24Vac (-25...+12%) or 24Vdc (-15...+25%) (50/60 Hz) 5 VA approx. 96 x 48 mm (1/8 DIN), depth 110 mm / 250g approx. Flush in panel in 92 x 45 mm hole Screw terminal block M3 for cables with section 1 mm² (18AWG) IP65 0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F) 5… 95% RH without condensation EN61010-1 (IEC1010-1) 7 9 PTC 1 Commands 2 Strain gauge transducer EXC 350 0 5 350 C 4 C 5 IL1 6 IL2 7 IL3 9 27 350 350 11 12 5/10 Vdc IN 1 mV 20 OP5 OP2 32 OP3 23 24 OP4 IN 2 31 33 34 35 36 CAL 24Vdc T ransmitter IN2 4…20mA mA Rcal DIMENSIONS j5 8 9 0 3 29 30 19 0 1 2 5 0 Alarm 28 OP1 10 SIG Power supply switch 25 26 3 8 ~ DIN RAIL MOUNTING CONTROLLERS RS485 3 5 V Recorder Supervision THERMOSTATS ANALOGUE CONTROLLERS CODE SPECIAL CONTROLLERS AND “CUSTOM” J5 Power supply 100… 240 Vac 24 Vac/Vdc OUT 1, 2, 3 e 4 Relay-Relay Relay-Relay-Relay-Relay Serial communication Not available RS485 SPECIAL FUNCTIONS Not available OUT 5 retransmission Input IN2 OUT 5 retransmission+ IN2 SPECIAL FUNCTIONS Not available INSTRUCTION MANUAL English Not available SPECIAL EXECUTION Not available Conformal coating 110 96 48 10 max. The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES Update measurement time Sampling rate Signal retransmission Serial communication Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Front protection degree Operating / storage temperature Operating humidity Conformity OUT 1: Relay SPDT, 2A/250Vac (4A/120Vac) for resistive loads OUT 2: Relay NO, 2A/250Vac (4A/120Vac) for resistive loads OUT 3: Relay NO, 2A/250Vac (4A/120Vac) for resistive loads OUT 4: Relay NO, 2A/250Vac (4A/120Vac) for resistive loads OUT 5: 0/4...20 mA for inputs retransmission 24 Vdc (±20%)/30 mA max. for external transmitter 4, programmable as alarm J5 To compose the part number, pls. choose one of the option for each variable PAC SYSTEMS Auxiliary power supply Outputs configuaration FUNCTIONAL 0...20/50/100 mV, 0...1/5/10 V, 0/4...20 mA, strain gauge: from 350 Ω, with bridge excitation 5 V or 10 V 0/4...20 mA or 0/1...5 V, 0...10 V 3, logic type not isolated 0.1% ±1 digit (for mA and mV) CONNECTIONS PREPROGRAMMED SYSTEMS Up to 5 J5 5 digit programmable as red or green, h 15.5 mm PLC AND OPERATOR PANELS DISPLAY Single INPUTS Main input (IN1) Auxiliary input (IN2) Digital inputs Accuracy OUTPUTS TIMERS COUNTERS POWER LIMITERS HOW TO ORDER FEATURES ADVANCED PROGRAMMER CONTROLLERS •Indicator-transmitter •strain gauge INPUT for melt pressure and load cells INDICATORS j5 IND U S T R I A L aut o m ati o n | indi c at o rs 158 159 acquisition and data recording Nothing is so easy 160 161 i/o modules Data acquisition modules in Modbus RTU and CANOpen Many typologies of digital and analogue inputs and outputs. 162 163 ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS a c q uisi z i o ne e r e gistra z i o ne dati | m o duli di i / o features Dimensions (mm) Single module (76 x 110 mm) Dual module (152 x 110 mm) Input channels Output channels Inputs Outputs 24 Vdc 120 Vac 24 Vdc 250 Vac Relay Outputs 2A Outputs 6A Power supply 24 Vdc CANOpen protocol Modbus RTU protocol CE certification + UL approval (listed) Inputs 16 16 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · DM 32LV 08TS · · 32 · 32TS 16TS · 16TP · · 8 8 · · 16 16 · 16 · 16 · · · · · · 8 · 16TS · 32TR · THERMOSTATS ANALOGUE CONTROLLERS SPECIAL CONTROLLERS AND “CUSTOM” · PAC SYSTEMS · · · · DO 32TS 04RL · 04TX · · 32 32 · 08RL · 4 4 8 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · TDA 4 Din modules (70 x 85 mm) PTC, NTC or Pt1000 4…20 mA 0… 10 V Digitals 04 · 4 · · · · · 08 · 8 · · · · ACCESSORIES Power supply 24, 110, 230 Vac CE certification DI 16HV · · 8 · features Dimensions (mm) Input channels 16LV · · 8 PREPROGRAMMED SYSTEMS · · 08dp · PLC AND OPERATOR PANELS Resolution 16 bit Accuracy 0.1% Power supply 24 Vdc Fast aquisition CANOpen protocol Modbus RTU protocol CE certification + UL approval (listed) · · 08HL · TIMERS COUNTERS POWER LIMITERS · · · · · · · · · · · · 08DP · 8 INDICATORS Thermocouples J,K,N,S,R,T RTD PT100 and PT1000 Current (mA) Voltage (mV) Voltage (V) Potentiometer Dual polarity AO 08HL · 8 SUPERVISION Type of inputs Single module (76 x 110 mm) ai 08TC · 8 COMBUSTION CONTROL Dimensions (mm) Input channels Output channels AI 04RT · 4 02UI · 2 I/O MODULES features DIN RAIL MOUNTING CONTROLLERS i/o modules 164 165 a c q uisi z i o ne e r e gistra z i o ne dati | m o duli di i / o Outputs OUT1-OUT2 OUT1 and OUT2: Relay NO, 2A res./250Vac (4A res./120Vac) / SSR, 1A res./250Vac Outputs OUT3-OUT4 -- Output OUT5 Outputs functions Auxiliary supply Outputs configuration Alarm functions FUNctional Setpoint Special functions (optionals) Front indication LEDs Unit of measurement Signal retransmission Serial communication Baud rate Parameters access GENERAL Power supply Power consumption Dimensions Weight Connections Mounting Protection degree Operating / storage temperature Operating humidity Conformity OUT1 and OUT2: Relay NO, 2A res./250Vac (4A res./120Vac)/SSR, 1A res./250Vac, logic 0/5 Vdc, not insulated OUT3 and OUT4: logic 0/5 Vdc, not insulated OUT5: 0/4… 20 mA, 15V max. -NOT +24dc, ±20%, 30 mA max. to supply an external transmitter Up to 3 alarms Up to 4 alarms Sensor break, Latching/Blocking, Loop break, Heater break associated to the timer (if available) Reference value --NOT, PWM, Hold -- Reference value -- 3 red (DO) + 1 green (PWR/COM) 4 red (DO) +1 green (PWR/COM) ---NOT, Toggle, Flip-Flop 6 yellow (DI), 2 red (DO), 1 green (PWR/COM) -- OP5 NO OP1 OP2 RS485 N 24V L IL TTL NO 24V NPN Power supply switch Connector for power supply and serial communications bus (female) NC 24VDC External Shunt 2.5Ω mV 0 5 TTL NPN Hz 0 2 Pt100 d8 0 0 9 mA OP1 OP2 TTL NO Hz NO Plug with termination resistor for serial comm.s bus (male) Configuration and Supervision NPN RS485 DI1 DI2 NC 24V N Power supply switch L TTL DI5 DI6 DI3 DI4 Connector for power supply and serial comm.s bus (female) NO 0 3 NPN dimensions NPN NO NO NO NPN NPN TTL TTL d9 Plug with termination resistor for serial comm.s bus (male) d7 / d8 / d9 22.5 9 10 99 mV 9 10 OP1 OP2 OP3 OP4 Configuration Power supply and Supervision and serial communications bus connector (female) RS485 5 4 3 2 1 NC N L IL1 External Shunt 2.5Ω 24V Power supply switch 114.5 4 VA max. 155 g approx. 24Vac (-25...+12%), 24Vdc (-15...+25%) (50/60Hz) 5 VA max. 22.5 x 99, depth 114.5 mm 156 g approx. PWS and COM: 0.08… 1.5 mm² (AWG28-AWG16) Inputs/Outputs: 0.2… 2.5 mm² (AWG24 - AWG12) On OMEGA DIN A rail IP20 (terminal block) 0… 50°C (32… 122°F)/-30… 70°C (-22… 158°F) 5… 95 RH% without condensation EN61010-1 (IEC1010-1) mA 4 VA max. 9 10 11 152 g approx. Pt100 IN2 NO 13 14 IN1 6.3 The dimensions are expressed in mm mV NPN 13 14 External Shunt 2.5Ω mA TTL 13 14 15 THERMOSTATS ANALOGUE CONTROLLERS mA NO NC 5 DIN RAIL MOUNTING CONTROLLERS Configuration and Supervision SPECIAL CONTROLLERS AND “CUSTOM” 0 1 2 3 4 5 NC TTL °C/°F or engineering units (-999… 9999) Measure or setpoint retransmission -(reference value) Isolated RS485 with Modbus RTU protocol RS 485 (MASTER or SLAVE) 1200, 2400, 4800, 9600 bit/s 3 wires Through serial line and supervision software Note: these modules can be inserted into Profibus DP and DeviceNet nets, together with a DX module, with the possibility of automatic reconfiguration. 166 5 4…20mA Plug with termination resistor for serial communications bus (male) PAC SYSTEMS OUTPUTS Code PREPROGRAMMED SYSTEMS 1 voltage digital input (+ 2 configurables) D7/D8/D9 power supply 24 Vac/Vdc OUT 1 and out 2 Relay (D7 only) Relay-Relay Relay-Logic (D8 and D9 only) Logic-Logic (D8 and D9 only) Triac-triac (D8 and D9 only) Triac-Logic (D8 and D9 only) Serial communication RS485 Option 1 Not available Continuous output (D7 only) special functions Not available instruction Manual Italian / English Not available Option 2 Shunt 1% (D7 and D9 only) Shunt 0.1% (D7 and D9 only) Option 3 Not available Conformal coating PLC AND OPERATOR PANELS -6 digital inputs in voltage or for free voltage contacts, in 2 groups optoisolated (1 and 2 in Hz) d7 To compose the part number, pls. choose one of the option for each variable TIMERS COUNTERS POWER LIMITERS 1 voltage digital input -- COnnections INDICATORS Digital inputs Input configuration D8 -- I/O MODULES Accuracy D7 D9 1 2 Thermocouples: L/J/E (0… +600°C / 32… +1112°F), T (-200…+400°C / -328…+752°F), K/N (0…+1200°C / 32…+2192°F), S/R (0... +1600°C / 32...2912°F), B (0... 1800°C / 32... 3272°F), Ni-NiMo (0... 1100°C / 32... 2012°F), W3, W5 (0... 2000°C / 32... 3632°F)) Thermoresistances: PT100 (-99.9... 300.0°C / -99.9... 572.0°F and -200... 600°C / -328... 1112°F) Linear signals: 0/10...50 mV; 0/4...20 mA (shunt) Infrared sensors or programmable on special ranges (custom) 0.25% ±1 digit (thermoelements); 0.1% ±1 digit (mA and mV) Pt100 SUPERVISION INPUTS Number of inputs COMBUSTION CONTROL how to order features ACCESSORIES •analogue and digital acquisition Modules •analogue universal transmitter with alarms •RS485 ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS d7/d8/d9 167 a c q uisi z i o ne e r e gistra z i o ne dati | m o duli di i / o INDUSTRIAL CONTROLLERS analogue i/o mA, V mA, V dual polarity -- IO-CBAI02UI CANOpen 8 IO-CBAI04RT IO-MBAI04RT IO-CBAI08TC IO-MBAI08TC IO-CBAI08HL IO-MBAI08HL IO-CBAI08DP CANOpen Modbus CANOpen Modbus CANOpen Modbus CANOpen -- Type of outputs -- Available 60 ms -Available RS 485, with dual connector RJ45 16 bit 800V 120 ms 10 ms IO-MBAI08HLT0- Modbus analogue outputs IO-CBAO08HL IO-MBAO08HL IO-CBAO08DP CANOpen Modbus CANOpen mA, V V dual polarity Available -- 24Vdc (-15...+25%) (50/60Hz) 4 VA max. 110 x 66 mm, depth 76 mm / 220 g approx. On OMEGA DIN A rail 2 terminal blocks with 11 poles 5.0mm, with screws or CLAMP terminals IP20 (terminal block) 0... 55°C/ -20… 85°C (32… 131°F / -4… 185°F) 5… 95% RH% without condensation EN 50081-2, EN 50082-2, EN 61010 20 ms RTD, Tc, mA, mV, V, potentiometer RTD, Tc, mV RTD, Tc, mV TC, mV TC, mV mA,V unipolar mA,V unipolar V dual polarity mA,V unipolar, Conformal coating Thermocouples 2 4 4 8 8 8 8 8 Thermoresistances Linear signals Potentiometer 8 mA,V unipolar mA,V unipolar V dual polarity 8 8 8 dimensions analogue i/o 65.8 accessories 12.7 RTD, TC, mV CABLES APS2 LOCALBUS76 APS2 LOCALBUS152 APS2 LOCALBUS500 POWER ADAPTOR 3.2 A POWER ADAPTOR 5 A PLUG WITH 11 polE CLAMP TERMINALS PLUG WITH 11 polE SCREW TERMINALS TERMINAL BLOCK CONNECTOR RJ45 WITH CAN TERMINAL 76 45.2 152 20.6 22 The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES POWER ADAPTORS APS2 ALDR75-24 APS2 ALDR12024 PLUGS APS2 SPINAM11 APS2 SPINAV11 TERMINALS AND conneCTORS APS2 TB2111 APS2 TERMCAN CaBLE WITH conneCtor RJ45 L=14 cm FOR RS485 CaBLE WITH conneCtor RJ45 L=22 cm FOR RS485 CaBLE WITH conneCtor RJ45 L=50 cm FOR RS485 46.2 TC, mV DIN RAIL MOUNTING CONTROLLERS L/J (-200… +600°C/-328… +1112°F), T (-200…+400°C/-328…+752°F), K (-200…+1370°C/328…+2498°F), N (0... +1300°C/32... 2372°F), S (0... +1760°C/ 32... +3200°F), R (0... +1600°C/32...2912°F) PT100/PT1000 (-200... +600°C/-328...+1112°F) 0...100 mV, 0...1000 mV, ±100mV, ±1000mV ±50 mV, ±300, ±1.0 V mA, (0,4… 20 mA), V (0...10V) 100...10K Ω THERMOSTATS ANALOGUE CONTROLLERS RANGE SPECIAL CONTROLLERS AND “CUSTOM” channels I O PAC SYSTEMS description PREPROGRAMMED SYSTEMS Protocol 8 0.1% 2500 V 20 ms Code PLC AND OPERATOR PANELS AO-08DP TIMERS COUNTERS POWER LIMITERS AO-08HL INDICATORS AI-08DP analogue inputs Accuracy OUTPUTS Number of outputs FUNctional Modbus protocol CANOpen protocol Serial communication Resolution Isolation class Aquisition time GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Protection degree Operating / storage temperature Operating humidity Conformity AI-08HL 69.3 AI-04RT 4 40.7 AI-08TC 8 46.2 Type of inputs (see table on next page for input ranges) AI-02UI 2 Universal: RTD, TC, mA, mV, V, potentiometer 110 INPUTS Number of inputs input range how to order features ADVANCED PROGRAMMER CONTROLLERS •analogue aCquisition modules •up to 8 inputs and 8 outputs 168 169 a c q uisi z i o ne e r e gistra z i o ne dati | m o duli di i / o INDUSTRIAL CONTROLLERS digital i/o Protection degree Operating / storage temperature Operating humidity Conformity 24 Vdc 2A 500 mA Available Available Available RS 485, with dual connector RJ45 2500 V -- 800 V CANOpen Modbus CANOpen CANOpen 24 Vdc PNP 24 Vdc PNP 24 Vdc PNP 24 Vdc PNP 16 16 16 32 CANOpen Modbus CANOpen CANOpen 24 Vdc 0.5 A 24 Vdc 0.5 A 24 Vdc 2 A 24 Vdc 0.5 A digital i/o 65.8 16 16 16 32 76 45.2 152 22 Note: through modules DX and DY, these instruments can be interfaced on Profibus, CANOpen and DeviceNet nets. PREPROGRAMMED SYSTEMS 24Vdc (-15...+25%) (50/60Hz) 4 VA max. 152 x 110 mm, 152 x 110 mm, 76 x 110 mm, depth 66 mm 76 x 110 mm, depth 66 mm depth 66 mm depth 66 mm 220 g 360 g 220 g 360 g On OMEGA DIN A rail 4 terminal blocks 4 terminal blocks with 11 poles 2 terminal blocks with 11 poles 5.0mm, with 11 poles 2 terminal blocks with 11 poles 5.0mm, 5.0mm, with screws or CLAMP terminals 5.0mm, with screws or CLAMP terminals with screws with screws or CLAMP terminals or CLAMP terminals IP20 0... 55°C / -20… 85°C (32… 131°F / -4… 185°F) 5… 95% RH% without condensation EN 50081-2, EN 50082-2, EN 61010 20.6 PAC SYSTEMS 46.2 800 V -- 500 mA channels I O THERMOSTATS ANALOGUE CONTROLLERS -- 32 description SPECIAL CONTROLLERS AND “CUSTOM” 16 digital inputs IO-CBDI16LV IO-MBDI16LV IO-CBDI16HV IO-CBDI32LV digital outputs IO-CBDO16TS IO-MBDO16TS IO-CBDO16TP IO-CBDO32TS dimensions Protocol 69.3 -- Code 40.7 115 Vac DO-32TS 12.7 24 Vdc DO-16TP 46.2 16 DO-16TS accessories CABLES APS2 LOCALBUS76 APS2 LOCALBUS152 APS2 LOCALBUS500 POWER ADAPTOR 3.2 A POWER ADAPTOR 5 A PLUG WITH 11 polE CLAMP TERMINALS PLUG WITH 11 polE SCREW TERMINALS TERMINAL BLOCK CONNECTOR RJ45 WITH CAN TERMINAL ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES POWER ADAPTORS APS2 ALDR75-24 APS2 ALDR12024 PLUGS APS2 SPINAM11 APS2 SPINAV11 TERMINALS AND conneCTORS APS2 TB2111 APS2 TERMCAN CaBLE WITH conneCtor RJ45 L=14 cm FOR RS485 CaBLE WITH conneCtor RJ45 L=22 cm FOR RS485 CaBLE WITH conneCtor RJ45 L=50 cm FOR RS485 PLC AND OPERATOR PANELS Connections DI-32LV 32 24 Vdc TIMERS COUNTERS POWER LIMITERS Weight Mounting DI-16HV INDICATORS Dimensions DI-16LV 110 INPUTS Number of inputs Type of inputs OUTPUTS Number of outputs Voltage Current FUNctional Modbus protocol CANOpen protocol Serial communication Isolation class GENERAL Power supply Power consumption DIN RAIL MOUNTING CONTROLLERS how to order features ADVANCED PROGRAMMER CONTROLLERS •digital aCquisition modules •up to 32 inputs and 32 outputs •rs485 170 171 a c q uisi z i o ne e r e gistra z i o ne dati | m o duli di i / o INDUSTRIAL CONTROLLERS digital i/o Protection degree Operating / storage temperature Operating humidity Conformity Available RS 485, with dual connector RJ45 4000 V 800 V -- 800 V 24 Vdc (-15...+25%) (50/60 Hz) 4 VA max. 152 x 110 mm, 110 x 76 mm, depth 76 mm depth 66 mm 360 g 220 g 76 x 110 mm, depth 66 mm 220 g 8 IO-CBDM08TS CANOpen IO-MBDM08TS Modbus IO-CBDM16TS CANOpen IO-CBDM32TS CANOpen 24 Vdc PNP 24 Vdc 0.5 A 24 Vdc PNP 24 Vdc 0.5 A 25 Vdc PNP 24 Vdc 0.5 A 26 Vdc PNP 24 Vdc 0.5 A 8 76 DIN RAIL MOUNTING CONTROLLERS 45.2 152 8 20.6 22 8 8 16 16 THERMOSTATS ANALOGUE CONTROLLERS 65.8 The dimensions are expressed in mm accessories CABLES APS2 LOCALBUS76 APS2 LOCALBUS152 APS2 LOCALBUS500 POWER ADAPTORS APS2 ALDR75-24 APS2 ALDR12024 PLUGS APS2 SPINAM11 APS2 SPINAV11 TERMINALS AND conneCTORS APS2 TB2111 APS2 TERMCAN CaBLE WITH conneCtor RJ45 L=14 cm FOR RS485 CaBLE WITH conneCtor RJ45 L=22 cm FOR RS485 CaBLE WITH conneCtor RJ45 L=50 cm FOR RS485 POWER ADAPTOR 3.2 A POWER ADAPTOR 5 A PLUG WITH 11 polE CLAMP TERMINALS PLUG WITH 11 polE SCREW TERMINALS TERMINAL BLOCK CONNECTOR RJ45 WITH CAN TERMINAL ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES Note: through modules DX and DY, these instruments can be interfaced on Profibus, CANOpen and DeviceNet nets. CANOpen 152 x 110 mm, depth 66 mm 360 g 4 terminal blocks 4 terminal blocks with 11 poles with 11 poles 2 terminal blocks with 11 poles 5.0mm, 5.0mm, 5.0mm, with screws or CLAMP terminals with screws with screws or CLAMP terminals or CLAMP terminals IP20 0... 55°C/ -20… 85°C (32… 131°F / -4… 185°F) 5… 95% RH% without condensation EN 50081-2, EN 50082-2, EN 61010 2 terminal blocks with 11 poles 5.0mm, with screws or CLAMP terminals 4 4 IO-CBDO08RL SPST-NO 2 A SPST-NO 6 A 4 SPST-NO 2 A + 4 SPDT 2 A DIGITAL I/O 500 mA Available CANOpen CANOpen SPECIAL CONTROLLERS AND “CUSTOM” -- RELAY OUTPUTS IO-CBDO04RL IO-CBDO04TX digital i/o PAC SYSTEMS 6A -24 Vdc channels I O 40.7 250 Vac Relay -2 A (SPST) 1 A (SSR) description 46.2 24 Vdc Relay -- 16 Protocol 12.7 8 dimensions Code PREPROGRAMMED SYSTEMS Connections 24 Vdc 4 4000 V DM-32TS 16 8 -- 250 Vdc Relay -2 A (SPST) 1 A (SSR) DM-16TS PLC AND OPERATOR PANELS Weight Mounting DM-08TS TIMERS COUNTERS POWER LIMITERS Dimensions DO-08RL INDICATORS FUNctional Modbus protocol CANOpen protocol Serial communication Isolation class GENERAL Power supply Power consumption DO-04TX 46.2 Current DO-04RL 110 INPUTS Number of inputs Type of inputs OUTPUTS Number of outputs Relay Voltage 69.3 how to order features ADVANCED PROGRAMMER CONTROLLERS •digital acquisition modules •up to 16 inputs and 16 outputs •rs485 172 173 a c q uisi z i o ne e r e gistra z i o ne dati | m o duli di i / o Accuracy OUTPUT One FUNctional Serial communication Baud rate Sampling rate Range GENERAL Power supply Power consumption Dimensions / Weight Connections Mounting Operating / storage temperature Operating humidity Conformity 4 digital inputs for free voltage contacts 0/4…20 mA or 0/2…10 V -8x Thermistors PTC KTY 81-121 (990Ω at 25°C) -or NTC 103AT-2 (10KΩ at 25°C) or 8x Thermoresistances Pt1000 (1KΩ at 0°C) ±0.5% fs 1 Relay SPST-NO (5A-AC1, 2 A-AC3/250 Vac) RS485 optoisolated – MODBUS RTU (JBUS) protocol Programmable between 1200 and 38400 baud 2 samples per second 350 points According to the used probe 24, 115, 230 Vac ±10% (50/60 Hz) 5 VA approx. 4 DIN rail module 70 x 84 x 60 mm / 210 g approx. Screw terminal block 2.5 mm² On OMEGA DIN A rail 0… 50°C (32… 122°F) / -30… 70°C (-22… 158°F) 30…95 RH% without condensation Directive CEE EMC 2004/108/CE (EN 61326), Directive CEE BT 2006/95/CE (EN 61010-1) COnnections Tda04 To compose the part number, pls. choose one of the option for each variable TDA04 input 0/2…10V 0/4…20 mA power supply 24 Vac 115 Vac 230 Vac Code DIGITAL IN D1 W I D3 D4 RS 485 GND B A OUT 1 2 3 4 5 6 7 8 9 10 11 12 A C D RELAY TDA04 C NO IN1 IN2 IN3 IN4 13 14 15 16 17 18 19 20 21 22 23 24 - Code D2 SUPPLY 4..20 mA TDA08 input PT1000 NTC PTC power supply 24 Vac 115 Vac 230 Vac DIN RAIL MOUNTING CONTROLLERS TDA08 THERMOSTATS ANALOGUE CONTROLLERS 8 probe inputs TDA04 I + I + + (Passive Probe) 0/4..20 mA 0/2..10 V ext. gen. + ext. gen. I + + - + I + + - G ext. gen. + ext. gen. + - G SPECIAL CONTROLLERS AND “CUSTOM” INPUTS Digital inputs 4 analogue inputs - + G G ACTIVE P N E PAC SYSTEMS how to order FEATURES Tda08 DIGITAL IN A C D D1 D2 D3 D4 SUPPLY RS 485 GND B PREPROGRAMMED SYSTEMS •analogue and digital acquisition modules •rs485 •4 or 8 inputs ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS tda A OUT 1 2 3 4 5 6 7 8 9 10 11 12 RELAY TDA08 C NO IN2 IN3 IN4 IN5 IN6 IN7 IN8 TIMERS COUNTERS POWER LIMITERS IN1 PLC AND OPERATOR PANELS 13 14 15 16 17 18 19 20 21 22 23 24 dimensions 70 27 21 INDICATORS tda04 / tda08 12 I/O MODULES 1 2 3 4 5 6 7 8 9 10 11 12 SUPERVISION 45 84 60 TDA 13 14 15 16 17 18 19 20 21 22 23 24 ACCESSORIES COMBUSTION CONTROL The dimensions are expressed in mm 174 175 supervision AutoLink, DX and DY Gateways SCADA Software for the centralized management and the supervision of plants. Protocol converters for the integration of the Modbus RTU instrumentation with other field bus. 176 177 supervision Functions DY5121 · THERMOSTATS ANALOGUE CONTROLLERS · · · · 2 · · · · · 8 · · 4 · · · · · ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS TIMERS COUNTERS POWER LIMITERS PLC AND OPERATOR PANELS PREPROGRAMMED SYSTEMS Power supply 24 Vac/Vdc CE certification + UL approval (listed) DY · SPECIAL CONTROLLERS AND “CUSTOM” Protocol DX · PAC SYSTEMS Dimensions (mm) Deltadue module (22.5 x 99 mm) 4 DIN rail module (70 x 85 mm) Modbus RTU CANOpen Profibus DP slave DeviceNet Modbus TCP Multi master Backup instruments (max.32) Data transfer (binding) E-mail and SMS Webserver DIN RAIL MOUNTING CONTROLLERS ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS a c q uisi z i o ne e r e gistra z i o ne dati | S U P E R V I S I O NE 178 179 INDUSTRIAL CONTROLLERS Device autorecognition and project automatic creation (Autolink QuickDIN) Device autorecognition and project automatic creation (W-Tec) 128, 256, 2048, 62536 Numerics, digitals, strings, composites Unlimited Binary, DBF and CSV file types 32 Unlimited Unlimited Unlimited, max 10 traces per window Unlimited and customizables Up to 999 Events schedulings, remote control, macros, multilanguages, SMS Ethernet Stazioni operatore AUTOLINK AUTOLINK AUTOLINK Controllori DIN RAIL MOUNTING CONTROLLERS Gestione Fabbrica THERMOSTATS ANALOGUE CONTROLLERS Serial lines, USB (with adapters), Ethernet Modbus RTU/ASCII, Modbus TCP, RTU Remote /ASCII Remote - Allen-Bradley Df1 Full Duplex Protocol For (Plc 3 and Plc 5), Slc 500 - AVEBus - Data Stream - Decom Contrex - Eurotherm Bisynch ASCII Gefran - Cencal - Idec Izumi - Klockner Moeller Sucom - (A and A for Ps4) - Mitsubishi Fr-Cu03 - ODBC Client - Omron (Fins, Fins in Host Link, Sysmac) - OPC Client - Red Lion PAX-1/8 DIN Counter/Rate Meter Saia (P800 and S-Bus) - Siemens MPI, Prodave MPI Mini, Plc Simatic S5 - S7EV2001, Profibus Mater DP (Tecnint HTE), Profibus MPI and S7 (Applicom), Profibus PPI S7 200 (Applicom), PPI S7 200 (Adapter) Interconnections TCP/IP (Master/Slave) - Raw ASCII Output - Other available drivers development and runtime Software for deltaDUE, gammaDUE and sigmaDUE I/O Modbus instruments only Max 32 instruments development/Runtime key LSALINKDIN/USB max. 32 instruments DIN W-L development and Runtime software max. 128 variables development/Runtime key LSALINKDVS/USB max. 128 variables DVS-W-ES development and Runtime software max. 2048 variables development/Runtime key LSALINKDVM/USB max. 2048 variables DVM-W-EM development and Runtime software max. 65536 variables development/Runtime key LSALINKDVX/USB max. 65536 variables DVX W-EX Runtime Software Runtime key max. 65536 LSALINKRNT/USB variables RNT W-R ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS TIMERS COUNTERS POWER LIMITERS Unique functionalities Gammadue, Deltadue, Sigmadue TLK, K, R, Z, Y, X, KM, W Database and functionalities Number of variables Type of variables Alarms Trend Access levels Synoptic pages Alarm pages Trend pages Recipes Report Auxiliary functions autolink To compose the part number, pls. choose one of the option for each variable Pentium II, 512 MB RAM, CD rom, resolution 800x600 Windows 95, 98, 2000, NT, XP, Vista, 7 SPECIAL CONTROLLERS AND “CUSTOM” Drivers COnnections PAC SYSTEMS Hardware and Sofware Hardware Supported OS Communications Interfaces PREPROGRAMMED SYSTEMS how to order features ADVANCED PROGRAMMER CONTROLLERS •Supervision and data acquisition software PLC AND OPERATOR PANELS autolink a c q uisi z i o ne e r e gistra z i o ne dati | S U P E R V I S I O NE 180 181 a c q uisi z i o ne e r e gistra z i o ne dati | S U P E R V I S I O NE INDUSTRIAL CONTROLLERS dx / dy GENERAL Power supply Power consumption Dimensions / Weight Mounting Connections Protection degree Operating / storage temperature Operating humidity Conformity RS232 standard ( for instrument configuration only) Ethernet 10/100 Mbaud, RJ45 female connector RS485 Modubus RTU (max. 115 K baud) RS485 CANOpen (max. 1 Mb/s) 24Vac (-25...+12%), 24Vdc (-15...+25%) (50/60Hz) 4VA max. 22.5 x 99 mm, depth 114.5 mm / 200 g approx. On OMEGA DIN A rail PWS and COM: 0.08… 1.5 mm² (AWG28-AWG16) Inputs/Outputs: 0.2… 2.5 mm² (AWG24 - AWG12) IP20 (terminal block) 0... 50°C (32… 122°F) / -20… 70°C (-4… 158°F) 5… 95% RH% without condensation CE, UL, CSA, EN61010-1 (IEC1010-1) CE, EN61010-1 (IEC1010-1) dy DY protocol converter CAN Open/Modbus RTU - Delta2 Case WEB+Modbus TCP/RTU - 4 DIN Case TCP/RTU Modbus multiple connection - Delta2 Case INSTRUCTION MANUAL Italian / English English Code DIN RAIL MOUNTING CONTROLLERS CodE THERMOSTATS ANALOGUE CONTROLLERS 5 SPECIAL CONTROLLERS AND “CUSTOM” 0 1 2 3 4 0 1 5 7 PAC SYSTEMS RS485 Modbus RTU master protocol (max.19200 baud) RS485, RS232 Modbus RTU slave protocol, insulated (max.38400 baud) RS485 Modbus RTU slave protocol, insulated (max. 57600 baud) RS485 Profibus DP slave (max. 12 Mb/s) dx DX Gateway/Manager for Delta2/Gamma2 series POWER SUPPLY 24 Vac/Vdc NumBER OF INSTRUMENTS in backup 0 Instruments 4 Instruments 8 Instruments 16 Instruments 32 Instruments fieldbus communication No fieldbus DeviceNet ModBus ProfiBus DP Option 1 Not available special functions Not available INSTRUCTION MANUAL Italian / English Not available Option 2 Not available Option 3 Not available Conformal coating 0 PREPROGRAMMED SYSTEMS Communications ports -- Binding (data transfer) Protocol converter between CANOpen or Modbus TCP to Modbus RTU Instruments template 30 pages of 20 variables 64 alarms (e-mail and SMS with external modem, GSM or GPRS). A 64 variables log file (CSV), can be periodically send by e-mail Trend graphics (if JAVA is installed) To compose the part number, pls. choose one of the option for each variable 0 0 9 0 PLC AND OPERATOR PANELS WebSCADA functions -- COnnections 0 3 DY5030 DY5121 DY5220 TIMERS COUNTERS POWER LIMITERS Gateway functions DY dimensions dx / dy 22.5 0 8 INDICATORS Manager functions DX Connected modules (max. 32) configuration and parameters data backup Hot swapping, automatic configuration and setup of the replaced modules. RS232/485 converter Protocol converter between Profibus DP SPC3, DeviceNet and Modbus RTU I/O MODULES FUNctional 99 114.5 6.3 SUPERVISION how to order features ADVANCED PROGRAMMER CONTROLLERS •protocol Gateways ACCESSORIES COMBUSTION CONTROL The dimensions are expressed in mm 182 183 Emission analysis and combustion control Energy saving solutions 184 185 combustion control systems Combustion and monitorign systems in-situ for civil and industrial power plants composed of single or multiple boilers. In-situ probes and analyzer for continuous measurement of oxygen, smoke/air temperature and carbon monoxide in the flue gases. 186 187 Output range 4… 20mA Response time Heating up time Calibration 2-points Intervallo di calibrazione Error indicator Sensor heating up time Pluggable screw connectors ZO2-E-300 ZO2-E-500 ZO2-E-C100 accessories POWER ADAPTORS APS2 ALDR75-24 APS2 ALDR12024 ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS ZO2-I-500 THERMOSTATS ANALOGUE CONTROLLERS ZO2-I-300 zo2-I 300/500 description in-situ ZIRCONIUM OXIDE PROBE WITH integrated electronics L=300 mm in-situ ZIRCONIUM OXIDE PROBE WITH integrated electronics L=500 mm in-situ ZIRCONIUM OXIDE PROBE WITH EXTERNAL electronics L=300 mm in-situ ZIRCONIUM OXIDE PROBE WITH EXTERNAL electronics L=500 mm in-situ ZIRCONIUM OXIDE PROBE WITH EXTERNAL electronics L=100 mm SPECIAL CONTROLLERS AND “CUSTOM” Model zo2-e-300/500 POWER ADAPTOR 3.2 A POWER ADAPTOR 5 A ZO2-E-C100 ACCESSORIES COMBUSTION CONTROL rEMOTE CASE FOR ZO2-E-300/500 AND ZO2-E-C100 SUPERVISION I/O MODULES Operation interface Remote probe connection To compose the part number, pls. choose one of the option for each variable PREPROGRAMMED SYSTEMS O2%Measuring range Accuracy DIMENSIONS PLC AND OPERATOR PANELS Output ZO2-I/E Direct and continuous oxygen content measurement in wet flue gas Heated zirconium oxide ZrO2 600°C Stainless Steel AISI 316 1” NPT with 1” NPT sliding nipple IP 66 -20°C... +55°C 2-3 Kg 24 Vdc ±5% 1.2 A max. 4… 20 mA active or passive output, not isolated Adjustable via jumpers 0.3% ... 25% ±2% 0... 20.96% , 0... 25% Adjustable with keys < 5 sec. 15 min. 1%... 20.9% Procedure of calibration with keys 12 months Relay DPST, NC+NO and red led on card Relay intervention in case of: O2% <0.3% probe disconnettion probe anomaly heater anomaly supply voltage anomaly <15s Automatic temperature control Power supply 0... 24V Output 4… 20mA Fault signal contacts Sensor wiring (5 wires) Red led, green led and 3 keys With supplied cable (3 m) INDICATORS GENERAL Measurement type Sensor Max. Heater Probe material Process connection Head protection Ambient temperature Weight Power supply Power consumption PAC SYSTEMS HOW TO ORDER FEATURES DIN RAIL MOUNTING CONTROLLERS •zirconiUM oXIDE PROBE FOR O2 measurement TIMERS COUNTERS POWER LIMITERS zo2 EMI S S I O N A N A LY S I S A ND COMB U S T I O N CO N T R O L | COMP O NE N T S 188 189 Auxiliary analogue output Alarm output FUNCTIONAL Serial communication (optional) Baud rate GENERAL Power supply Power consumption Dimensions / Weight Mounting Front protection degree Operating / storage temperature Operating humidity Conformity -- 2 Relay NO, 250 Vac/5A programmable 4... 20 mA/0... 10 V control output 4... 20 mA/0... 10 V for O2% 3 Relay NO, 250 Vac/5 A programmable 1 Relay NO, 250 Vac/5 A Failure RS485 (2 wires) Mod Bus, J Bus 9600 baud max. 100... 240 Vac or 16... 28 Vac (50/60Hz) and 20...30 Vdc 4 VA max. 48 x 96 mm (1/16DIN) - depth 150 mm Flush in panel in 45 x 92 mm hole IP 65, mounted on panel with gasket 0… 50°C (32… 122°F)/-20…+70°C (-4… 158°F) 35… 85 RH% without condensation IEC801-2, 801-3, 801-4 3 5 0 1 2 3 1 2 0 1 2 oxm DIMENSIONS oxi / oxm / oxr 48 14 ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS 4... 20 mA/0... 10 V for O2% oxi CODE THERMOSTATS ANALOGUE CONTROLLERS Main analogue output 4... 20 mA/0... 10 V programmable for O2%,T smokes, T air, CO2%, �, l OXI/OXM/OXR Power supply 230 Vac 24 Vac/Vdc Serial communication Not available 20 mA Current Loop Ascon Tecnologic protocol 20 mA Current Loop ModBus protocol RS485 ModBus protocol OUT 1 4… 20mA retransmission 0… 10V retransmission OUT 2 (OXM and OXR only) Not available 0… 20mA retransmission 0... 10V retransmission SPECIAL CONTROLLERS AND “CUSTOM” OUTPUTS To compose the part number, pls. choose one of the option for each variable PREPROGRAMMED SYSTEMS Digital inputs and functions CONNECTIONS 150 PLC AND OPERATOR PANELS Auxiliary analogue inputs OXI - Indicator OXM - Monitor OXR - controller Direct in mV from ZO probe (0.2% ±1 digit) or 4... 20 mA linearized in the range 0.0... 20.9% 2 x 4... 20 mA from -4... 20 mA from boiler load signal smoke/air temperatures 4 logic inputs: 3 logic inputs: Hold, Fail, Hold, Fail, fuel switch, 2 logic inputs: Hold and Fail fuel switch Set Point mem., Auto/man. oxr 96 ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES The dimensions are expressed in mm TIMERS COUNTERS POWER LIMITERS INPUTS Main analogue input PAC SYSTEMS HOW TO ORDER FEATURES DIN RAIL MOUNTING CONTROLLERS •Indicator, monitor and controller for combustion control INDICATORS oxi/oxm/oxr EMI S S I O N A N A LY S I S A ND COMB U S T I O N CO N T R O L | COMP O NE N T S 190 191 Certifications INDUSTRIAL CONTROLLERS 2 m + extension 5 m Pressure: +2 mbar compared to the pressure at chimney Consumption: 30 m3/h max. Extension cable for connecting receiver-processing unit 10 or 15 meters (maximum distance receiver-processing unit without repeater: 17 meters) Optical alignment unit Specifiche EMC secondo EN 50081-1/EN 50082-2 Guidelines VDE EN 61010 (IEC 1010-1, VDE 0411), protection class 1, degree of protection IP65 CE (EMC EC Guideline 89/336 EWG, NSP 72/23/EWG TÜV Certification (Report no. 502/0741/96-20 081751) Code Ricevitore: 462 mm Trasmettitore: 300 mm 160 106 45˚ 10 45˚ Ø127 Ø100 90˚ Ø130 78,5 Ø14 8 60 80 Ricevitore: 322 Trasmettitore: 160 164 SPECIAL CONTROLLERS AND “CUSTOM” ZCO-IGM-901-00 Ø39,5 THERMOSTATS ANALOGUE CONTROLLERS Ø74 103,6 164 157 150 19 PAC SYSTEMS The dimensions are expressed in mm processing unit ACCESSORIes 200 Accessories Extension cable between receiver-processing unit 10 m Extension cable between receiver-processing unit 15 m Optical alignment unit Blower with air filter 0.55Kw 220-240 Vac 50/60 Hz single-phase Blower with air filter 0.55Kw 400 Vac 50/60 Hz three-phase Code AZCPROLUNGA10M AZCPROLUNGA15M AZC2020436 160 97,5 90 80 Ø8 PREPROGRAMMED SYSTEMS 15 m CO ANALYSIS SYSTEM COMPOSITION 1 transmitter 1 receiver 1 processing unit with connecting cable 2 m 1 extension cable between receiver-processing unit 5 m 1 connecting cable between transmitter-receiver 15 m 2 fixing flanges with connection for air instruments 2 tronchetti a saldare 2 kit special nuts and washers 2 seals tronchetti-flanges 1 manual 1 calibration certificate azcsOFFIANTEMGT230 AZCSOFFIANTEMGT400 PLC AND OPERATOR PANELS Conformity max. load 5V, 2 mA Fail and threshold Rating 1 A , 125 Vdc, 150 Vac max. (30 VA dc or 60 VA ac) 115/230 Vac 50/60 Hz (selectable via jumper) 75 VA IP 65 probe To compose the part number, pls. choose one of the option for each variable CONNECTIONS zco The dimensions are expressed in mm flange Tronchetto a saldare Ricevitore Trasmettitore Gas 15 Connessione aria strumenti Cavo di collegamento m 15 Prolunga: 5 m (standard) 10/15 m (opzionali) max. 17 m Ø140 Ø76 Unità di elaborazione I/O MODULES Ø70 Ø127 130 115/230 Vac 1 ingresso e 1 uscita analogica 1 ingresso e 2 uscite digitali The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION Cavo di collegamento (2 m) TIMERS COUNTERS POWER LIMITERS Options 0/4... 20 mA/500 Ω max. DIMENSIONS 332 300 Air instruments ZCO 0.5 m... 8.0 m (1.6... 26 ft) Programmable between 0...100 ppm and 0...20000 ppm 5% f.s. 5... 360 s ≤ 300°C (higher temperatures available on request) –20... +55°C 0... +55°C 0/4... 20 mA/100 Ω 23 GENERAL Measuring distance (TX-RX) Measuring range Accuracy Response time Gas temperature Ambient temperature Processing unit ambient temperature 1 analogue input for gas temperature 1 isolated analogue output for CO retransmission Digital input for plant 2 digital alarm outputs Outputs current Power supply Power consumption Protection degree Connection cable between transmitter-receiver Connection cable between receiver-processing unit DIN RAIL MOUNTING CONTROLLERS HOW TO ORDER FEATURES ADVANCED PROGRAMMER CONTROLLERS •CO in-situ analyzer INDICATORS zco EMI S S I O N A N A LY S I S A ND COMB U S T I O N CO N T R O L | COMP O NE N T S 192 193 ACCESSORIes flexible solutions for every requirements 194 195 accessories To complete the range... Together with our products we can also supply all the accessories of your applications: probes, sockets, gaskets, hole covers, programming keys, signal and protocol converters, front frame protections, external and current transformers, adapters and more... 196 197 Serial communication INDUSTRIAL CONTROLLERS A01 is able to recovery data from failed instruments too and permits unlimited copies of configuration, error free. Interface RS485, not insulated Interface TTL, not insulated GENERAL Connections To compose the part number, pls. choose one of the option for each variable A01 CONNECTOR 5 pole for 78x35, DIN rail, 72x72 series 3 pole for 48x48 series POWER ADAPTOR Available Not available kit for pc configuration USB cable and SW on Cdrom support Without cable and SW a01 Code 5 3 E S - The dimensions are expressed in mm ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS TIMERS COUNTERS POWER LIMITERS PLC AND OPERATOR PANELS PREPROGRAMMED SYSTEMS Operating / storage temperature Operating humidity TTL male connector: JST S 5B-PH-KL TTL female connector : SAMTEC SQT-105-02-L-S RS485 connector: Phoenix MC 1,5/3-G-3.5 PWS connector : Dc power Jack 1.3mm USB connector type: Mini-USB Dip switch: 4 ways 0… 50°C (32… 122°F) / -20…+70°C (-4… 158°F) 20… 95 RH% without condensation dimensions THERMOSTATS ANALOGUE CONTROLLERS Functions A01 The key is able to “dialogue” with: * An instrument and to copy parameters from it to the key and vice versa * A second key and to integrally copy its parameters * A Personal computer * A Personal computer and an instrument SPECIAL CONTROLLERS AND “CUSTOM” FUNctional DIN RAIL MOUNTING CONTROLLERS how to order features ADVANCED PROGRAMMER CONTROLLERS •universal programming key for Ascon Tecnologic instruments PAC SYSTEMS a01 a c c e ss o rie s | a c c e ss o rie s 198 199 a c c e ss o rie s | a c c e ss o rie s Connections Protection degree Mounting Operating / storage temperature Operating humidity Conformity From USB to RS485 auto powered From USB to TTL auto powered Automatic 38400, automatic selection 24 Vac/Vdc ±10% or 100… 240Vac (-15… +10%) (50/60 Hz) 5 VA max. 78x35 mm, depth 77,31 mm / 180 g PWS: screw terminal block (M3 screws, for cables φ 0.25 to φ 2.5 mm2 or AWG 23 to AWG 14) RS232/RS485: screw terminal block (M2 screws, for cables φ 0.25 to φ 1.5 mm2 or AWG 23 to AWG 16) IP20 (terminal block) On OMEGA DIN A rail 0… 50°C (32… 122°F)/-30…+70°C (-22… 158°F) 20… 85 RH% without condensation EN61326-1, EN61010-1 CONNECTIONS To compose the part number, pls. choose one of the option for each variable A30 Model From USB to RS485 or TTL From USB/RS232/RS485 to RS485 or TTL POWER SUPPLY 24 Vac/Vdc (A30 only) 100… 240 Vac (A30 only) 5V supplied by the USB port (A30U only) CONNECTIONS Plug-in screw type Plug-in screw type, fix part only a30 code U - THERMOSTATS ANALOGUE CONTROLLERS TX/RX commutation Baud rate GENERAL Power supply Power consumption Dimensions / Weight A30From USB to RS485 From USB to TTL From RS232 to RS485 From RS232 to TTL From RS485 to RS485 From RS485 to TTL L H - SPECIAL CONTROLLERS AND “CUSTOM” Interface type A30U E N DIMENSIONS ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS TIMERS COUNTERS POWER LIMITERS PLC AND OPERATOR PANELS a30 PAC SYSTEMS functional PREPROGRAMMED SYSTEMS how to order features DIN RAIL MOUNTING CONTROLLERS •signal converter from USB/RS232/RS485 to RS485/TTL ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS a30 200 201 Power supply for instruments of sigmadue series. Accessories used to adapt an instrument to an already existing hole, but with different mechanical measures. Code APS2 ALDR75-24 APS2 ALDR12024 Code BOX 04175 BOX 1002 ARFQ96D ARFQ96M description Adapter for hole from 75 x 32 to 58 x 26 mm Adapter for hole from 64,4 x 32,4 to 34,3 x 15 mm Adapter for hole from 96 x 96 to 48 x 96 mm Adapter for hole from 96 x 96 to 48 x 48 mm aps2 modem external gaskets for ip65 protection degree Modem GSM/GPRS in metallic case. External gaskets in neoprene mousse able to increase the instrument front protection degree. Code Code GUAR 6993 GUAR 6927 GUAR 6925 GUAR 6923 GUAR 6973 GUAR 6974 GUAR 6926 APS2 MODEMG100 description Modem for OMEGA DIN A rail mounting Dimensions 73 x 54 mm, depth 25 mm Pws: 230 Vac - 12 Vdc E-GSM Quad-band 850/900/1800/1900 MHz ETSI GSM Phase 2+ Class 4 (2W@ 850/900 MHz) Class 1 (1W@ 1800/1900 MHz) Antenna GSM: SMA-F connector PWS: 5.5 - 32 Vdc (micro-FIT connector) RS232 + Audio conn. female 15-pin Sub-D PLC AND OPERATOR PANELS TIMERS COUNTERS POWER LIMITERS INDICATORS description 48 x 48 mm (soft rubber) 48 x 48 mm (Plastic - IP65) 48 x 96 mm (Plastic) 48 x 96 mm (Plastic - IP65) 72 x 72 mm (Plastic) 96 x 96 mm (Plastic) 96 x 96 mm (Plastic) guar MODEM GSM/GPRS 202 Code CAL48x48-M CAL48x48-IP65 CAL48x96-I CAL48x96-IP65 CAL72x72-I CAL96x96-I CAL96x96-IP65 description 6 port Ethernet Switch - Plastic case 6 port Ethernet Switch - Metallic case 8 port Ethernet Switch - Metallic case I/O MODULES Code APS2 ATOPEH2006 APS2 ATOPEH2306 APS2 ATOPEH2308 Protection covers made of transparent plastic or soft rubber to protect the front of the instruments. Some models assure the IP65 protection degree. description IP65 gasket for 65 x 33 mm front IP65 gasket for 75 x 33 mm (old style) front IP65 gasket for 78 x 35 mm (new style) front IP65 gasket for 48 x 48 mm front IP65 gasket for 48 x 96 mm front IP65 gasket for 72 x 72 mm front IP65 gasket for 181 x 36 mm front SUPERVISION PROTEction covers Industrial Ethernet switches. COMBUSTION CONTROL industrial switches ACCESSORIES cal aps2 atopeh PREPROGRAMMED SYSTEMS PAC SYSTEMS description Power supply 75W - 24Vdc - 3.2 A Power supply 120W - 24Vdc - 5 A THERMOSTATS ANALOGUE CONTROLLERS ADApters power supply for SIGMADUE series SPECIAL CONTROLLERS AND “CUSTOM” box-ar aps2 aldr DIN RAIL MOUNTING CONTROLLERS ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS A CCE S S O R Ie s | A CCE S S O R Ie s 203 Accessories available with different ratio of current for different instrumentation demands. Code TAPPO 33X75 TAPPO 48x48 TAPPO 48x96 TAPPO 96x96 Code TR-AMP-100/02 TR-AMP-25/005 TR-AMP-200/04 TR-AMP-50/005 TR-AMP-100/005 description Cover for 75 x 33 mm hole Cover for 48 x 48 mm hole Cover for 48 x 96 mm hole Cover for 96 x 96 mm hole description Ratio 100/0.2 Ratio 25/0.05 Ratio 200/0.4 Ratio 50/0.05 Ratio 100/0.05 DIN RAIL MOUNTING CONTROLLERS current TRAnSFORMers Accessories used to cover an existing hole that it’s not possible to leave empty for aesthetic reasons or protection. THERMOSTATS ANALOGUE CONTROLLERS hole cover SPECIAL CONTROLLERS AND “CUSTOM” tr-amp Code Code ZOC 02203 ZOC 02805 ZOC 02204 ZOC 02976 ZOC 03110 description primary/secondary power 24/12 V 115/12V 230/12V power 3 VA 5 VA 10 VA 3 5 10 Code tlcov XX D S --1 111 204 description instrument to be extended Part.no to define the instrument to be extended Position of the instrument Instrument mounted on the right side Instrument mounted on the left side Holes dimensions Holes with Ø 20 mm Left hole with Ø 20 mm - Right hole with Ø 22 mm Left hole with Ø 22 mm - Right hole with Ø 20 mm Holes with Ø 22 mm COMBUSTION CONTROL Accessories that make it possible to extend the front plate of instruments 78 x 35 mm to 185 x 38 mm. Available also hole plugs and switches to cover the side holes. ACCESSORIES extended front plate SUPERVISION I/O MODULES Other models available on request. description Octal (IP20) Octal Undecal (IP20) Octal with terminals to be soldered Octal with screws PLC AND OPERATOR PANELS Accessories available in different executions: to be soldered, with screws. A C D tlcov sockets Accessories available with different ratio of transformation for different instrumentation demands. TIMERS COUNTERS POWER LIMITERS external power transformers INDICATORS zoc tctr PREPROGRAMMED SYSTEMS PAC SYSTEMS tappo ADVANCED PROGRAMMER CONTROLLERS INDUSTRIAL CONTROLLERS A CCE S S O R Ie s | A CCE S S O R Ie s 205 Here following just some of the possible execution of our thermoelements: • Probes for machines and small plants • Flexible probes with MgO insulation • High pressure probes with replaceable insertion • High temperature probes with ceramic or methalic sleeve • Accessories: nipple, thermowell, flanges and so on • Compensated cables INDUSTRIAL CONTROLLERS ADVANCED PROGRAMMER CONTROLLERS ACCESSORIES COMBUSTION CONTROL SUPERVISION I/O MODULES INDICATORS TIMERS COUNTERS POWER LIMITERS PLC AND OPERATOR PANELS PREPROGRAMMED SYSTEMS PAC SYSTEMS Our technical team is avaiable to discuss your requirements for custom made products. Get in touch with us. DIN RAIL MOUNTING CONTROLLERS probes and accessories To choose correctly the probe is often decisive for the good result of the process control. We, at Ascon Tecnologic puts at your disposition our experience and technical competence with the purpose to find the correct solution to every application problem... THERMOSTATS ANALOGUE CONTROLLERS •thermocouples •thermoresistances •thermistors •cables and accessories SPECIAL CONTROLLERS AND “CUSTOM” thermoelements A CCE S S O R Ie s | A CCE S S O R Ie s 206 207 analytical index A j a01 a30 APS2 ALDR APS2 Atopeh APS2 MODEM ANALOGue i/o autolink 198 200 202 202 202 168 180 BOX-AR brewery pac BWt40 203 118 138 c1 CAL clima pac cu02 32 203 116 110 d1 d2 d3 d7 d8 d9 digital i/o DX dy 70 70 70 166 166 166 170 182 182 c d e51a 86 GUAR 203 g 156 156 158 k30 k30 k31 k32 k38 k39 k31v k38v k48 k49 k48v k85v k85 k85 km1 km3 kr1 KR3 kx1 KX3 60 72 54 54 54 54 152 152 56 56 154 154 58 74 16 48 20 52 18 50 light pac 120 m1 m2 m3 m4 m5 m81 mp02 34 36 38 38 62 104 106 k b e J1 j3 j5 l m mp-d1 mp-d2 mp-d4 108 108 108 openpcs opMT oxi oxm oxr 112 128 190 190 190 p01 p04 p30 p32 132 126 132 132 tlk41 tlk42 tlk43 tlk72 tlk94 tlk96 tlz35 TLZ35 tp34 tp49 TR-AMP tt34 tt49 tt73 o p q q1 q3 q5 42 42 64 r38 22 r t TAPPO tc34 tc49 tc73 TCO30 tcpde TCTR TDA ThErmoelements tlcov tli40 tlk33 204 142 142 142 96 90 204 174 206 204 150 98 24 24 24 26 30 28 76 84 144 144 205 140 140 140 w w09 88 x1 x3 x5 40 40 64 x z Z31A zco zo2 ZOC 82 192 188 205 noteS ada usa mexico venezuela brazil ireland uk portugal spain france belgium holland luxembourg denmark germany tzerland austria finland norway sweden slovenia poland hungary czech rep. romania greece algeria tunisia rocco egypt jordan israel syria south africa CSI latvija kazakhstan turkey singapore hong kong thailand taiwan na australia new zeland canada usa mexico venezuela brazil ireland uk portugal spain france belgium holland embourg denmark germany switzerland austria finland norway sweden slovenia poland hungary czech rep. mania greece algeria tunisia morocco egypt jordan israel syria south africa CSI latvija kazakhstan turkey singapore ng kong thailand taiwan china australia new zeland canada usa mexico venezuela brazil ireland uk portugal spain nce belgium holland luxembourg denmark germany switzerland austria finland norway sweden slovenia poland ngary czech rep. romania greece algeria tunisia morocco egypt jordan israel syria south africa CSI latvija kazakhstan key singapore hong kong thailand taiwan china australia new zeland canada usa mexico venezuela brazil ireland PRODUCTION portugal spain france belgium holland luxembourg denmark germany switzerland austria finland norway sweden venia poland hungary czech rep. romania greece algeria tunisia morocco egypt jordan israel syria south africa latvija kazakhstan turkey singapore hong kong thailand taiwan china australia new zeland canada usa mexico SUBSIDIARIES ezuela brazil ireland uk portugal spain france belgium holland luxembourg denmark germany switzerland austria land norway sweden slovenia poland hungary czech rep. romania greece algeria tunisia morocco egypt jordan ael syria south africa CSI latvija kazakhstan turkey singapore hong kong thailand taiwan china australia new HEADQUARTERS and canada usa mexico venezuela brazil ireland uk portugal spain france belgium holland luxembourg denmark rmany switzerland austria finland norway sweden slovenia poland hungary czech rep. romania greece algeria the group Ascon Tecnologic s.r.l. viale Indipendenza, 56 · 27029 Vigevano (PV) Italy tel +39 0381 69 871 · fax +39 0381 69 87 30 info@ascontecnologic.com www.ascontecnologic.com Tecnologic Uk ltd Ascon Polska sp. z.o.o. Coelmatic ltda Unit No.1 Farnborough Business Centre Eelmoor Road · Farnborough Hampshire · GU14 7xa tel +44 125 2377 600 · fax +44 125 2377 60 sales@tecnologicuk.co.uk www.t-uk.co.uk Kochcice ul. Kochanowicka 43 42-713 Kochanowice tel +48 34 35 33 619 · fax +48 34 35 33 884 info@ascon.pl www.ascon.pl Al. Vincente Pinzon, 173 - 9° andar Sao Paulo · SP - CEP 04547 - 130 tel +55 11 2066-3211 · fax +55 11 3046-8601 info@coel.com.br www.coelmatic.com.br Ascon Tecnologic France Ascon Tecnologic North America Coelmatic Sapi Sa de Cv BP 76 · 77202 · Marne La vallee Cedex 1 tel +33 1 64 30 62 62 · fax +33 1 64 30 84 98 info@ascontecnologic.fr www.ascontecnologic.com/fr 1111 Brook Park Road Cleveland · OH 44109 tel +1 216 485 83 50 · Fax +1 216 398 85 53 info@ascontec-na.com www.ascontecnologic.com/en Paseo De Los Cipreses, 3720 Del Paseo Residencial, Monterrey Nuevo León · CP. 64920 tel +52 81 8104 1012 info@coelmatic.com.mx www.coelmatic.com.mx Printed in October 2013 Printed by: Tipolitografia Vaccarone - Vigevano (PV) Graphic project: www.elever.it