HandyLab MKII - SI Analytics

Transcription

HandyLab MKII - SI Analytics
HandyLab MKII
THE NEW HANDYLAB GENERATION - AVAILABLE WITH IDS
2
Content
The new HandyLabs MKII Page
4
HandyLab 100 Page
6
HandyLab 200
Page
8
HandyLab 600 Page 10
HandyLab 680
Page 12
Order information for HandyLab MKII Page 14
IDS Technology
Page 16
Overview and Ordering Information IDS Electrodes Page 18
Application Overview IDS Electrodes Page 20
About us
Page 22
3
The new HandyLabs MKII
Our 2nd generation of Handylab devices offers analog or digital options for the measurement of pH,
ORP, dissolved oxygen and conductivity in the lab and in the field.
While our Handylab 100 pH and Handylab 200 Cond offer a single traditional analog channel, our
IDS series Handylab 600 and 680 devices take full advantage of our new digital technologies. The
digital HandyLab 600 concentrates on the pH measurement as a one-channel device, whereas the
HandyLab 680 allows you to measure any two parameters simultaneously; pH, ORP, conductivity or
oxygen.
IDS stands for "intelligent, digital sensors" and means that the analog measuring signal is converted
into a digital measuring value in the sensor. This protects the signal from external interferences, such
as moisture, electro-magnetic fields or pulses. The higher measuring accuracy raises confidence in
your readings to a whole new level. IDS sensors send their type designation and serial number, i.e.
they identify themselves to the meter automatically. This information is always part of the
documentation. Calibration values are stored in the IDS sensor and transferred to the measuring
device avoiding unnecessary recalibration as would be needed for traditional analog devices.
Especially with field devices, the increased comfort is considerable as the IDS sensors can be
calibrated in the laboratory under optimal conditions and simply need to be connected in the field.
he advanced speed and precision of our
T
benchtops in a portable and durable design.
Specifically designed for mobile use
▶ Handy, battery-operated
▶ Keypad made from a continuous silicone mat
and therefore waterproof with noticeable key
click, even when used with gloves.
P67 classified
eproducible results due to active automatic
R
AutoRead function with independent detection of stabile measuring values.
MC (Continuous Measurement Control)
C
makes sure that the pH measuring values and
the calibration area remain in sight and that
the measurement is conducted in the optimal
range.
Generous data storage in all devices
Backlit graphics display in all versions
case for the safe storage and
A
transport is always included
with these devices.
Advantages
HandyLab MKII
4
HandyLab 680
Selection chart
HandyLab
Analog
IDS (Intelligent Digital Sensor)
One channel
Two channel
pH/ORP
Temperature
Conductivity
DO
CMC-Function
1- to 5-point calibration with 22 stored buffer
sets
QSC intelligent sensor evaluation
User administration
Autoread
Data memory
Interface Mini USB-B
Interface USB-A
Info display
Backlit B/W graphical display
Backlit colored graphical display
Battery (Typ AA)
Rechargable AA from included power supply.
Watertight housing and keypad (built of one
piece of silicone mat)
IP67 certified
100
200
600
680
5
HandyLab 100
The portable all-rounder for pH/mV measurements
The HandyLab 100 increases the measuring speed and accuracy thanks to the AutoRead and the CMC
function. AutoRead displays when the measuring value is stabile and eliminates the risk of a premature
reading of the faulty measuring value. CMC (Continuous Measurement Control) visualizes whether the
measuring value is still within the calibration limits. Having storage capacity for up to 200 data sets,
stored data can be viewed.
The HandyLab 100 pH is precise, robust and easy to use.
6
HandyLab
Technical specifications
Measuring
range/
resolution/
accuracy (all
values +/-1 digit)
mV
Calibration
Temperature
Calibration points
Handling
pH
Stored buffers
Calibration memory
AutoRead
Celsius/Fahrenheit
CMC
Display
Data memory
Logger
Power supply
Continious operating time
Sensor connector
Waterproof
-2.0 … 20.0 +/-0.1 pH
-2.00 … 20.00 +/-0.01 pH
-2.000 … 19.999 +/-0,005 pH
+/- 1200.0 mV +/- 0.3 mV
+/- 2500 +/-1 mV
-5.0 … 105.0 °C +/- 0.1 °C
1-, 2-, 3-, 4-, 5-Points
22 preloaded buffer sets
Latest calibration
Automatic/manual
Yes
Yes
LCD B/W Graphic backlit
Manual 200 data sets
Manual
4 x 1.5 V AA or 4 x 1.2 V NiMH rechargeable
battery
Up to 1000 h without/ 150 h with lighting
Waterproof DIN/ 4mm banana
IP67 (including battery compartment, USB
ports and channels)
b 100
Waterproof IP67
eproducible results due to
R
active automatic AutoRead
function
MC function to visualize the
C
optimal measuring range
to 5 point calibration with 22
1
stored buffer sets
ata storage with output on
D
display
acklit graphic display with clear
B
text menu
Advantages
HandyLab 100
7
HandyLab 200
The portable all-rounder for conductivity measurements
Due to the wide selection of 2 and 4 pole measuring cells made by SI Analytics, the system consisting of
a sensor and HandyLab 200 can be used for a variety of purposes such as conductivity, salinity, TDS and
specific gravity. Autoread provides a stabile, precise measuring value. The backlit display and waterproof
design make it especially ideal for field use.
For easy reference, the HandyLab 200 has a storage capacity for up to 200 data sets, which can be put
out on the display.
8
HandyLab
Technical specifications
Measuring
range/
resolution/
accuracy (all
values +/-1 digit)
Cell constant
Temperature
compensation
Handling
Conductivity
0.0 … 1000 mS/cm +/- 0.5 % from average
0.000 … 1.999 µS/cm, K= 0.01 cm-1 +/- 0,5 % of
the mean value
0.00 … 19.99 µS/cm, K= 0.010 cm-1; K=0.100
Specific resistance
cm-1 +/- 0,5 % of the mean value
1.000 Ohm cm … 199.9 MOhm cm +/- 0,5 % of
Salinity
TDS
Temperature
the mean value
0.0 … 70.0 (IOT)
0 … 1999 mg/l, 0 bis 199.9 g/l
-5.0 … 105.0 °C +/- 0.1 °C
Fixed
Calibratable (1 point)
Adjustable:
Adjustment
Temperature coefficent
AutoRead
Celsius/Fahrenheit
Display
Data memory
Logger
Power supply
Continious operating time
Sensor connector
Waterproof
b 200
0.475 cm-1, 0.100 cm-1, 0.010 cm-1
0.450 to 0.500 cm-1, 0.585 … 0.715 cm-1, 0.800
… 0.880 cm-1, Standard: 0.01 mol/L KCl
0.250 … 25.000 cm-1; 0.090 … 0.110 cm-1
Automatic/manual
nLF: none linear function according to EN 27
888 and ultrapure water function
Linear compensation 0.000 … 3.000 %/K
No Compensation
Automatic/manual
Yes
LCD B/W Graphic backlit
Manual 200 data sets
Manual
4 x 1.5 V AA or 4 x 1.2 V NiMH rechargeable
battery
Up to 800 h without/ 100 h with backlight
8 Pole
IP67 (including battery compartment, USB ports
and channels)
Waterproof IP67
eproducible results due to
R
active automatic AutoRead
function
ata storage with output on
D
display
acklit graphic display with
B
clear text menu
Advantages
HandyLab 200
9
HandyLab 600
The portable pH IDS measuring device for the safest
measuring and high operator comfort
The HandyLab 600 increases the measuring
accuracy via:
The HandyLab 600 increases the operator comfort via:
IDS technology (Intelligent Digital Sensor) - The
digitalization of the measuring signal eliminates
interferences.
IDS Technology - The secure allocation of the
calibration data to the sensor eliminates any
uncertainty about the date and results of its last
calibration. This saves time and money while assuring the highest confidence in your measurements.
AutoRead function - Autoread provides a stabile,
precise measuring value.
10
CMC (Continuous Measurement Control) - Visualizes whether the measuring value is within the calibration range.
Traceability of the measuring values - By the
digital and automatic capture of all sensor data.
QSC (Quality Sensor Control) - Informs about the
actual condition of the electrode and therefore
increases operation safety.
Transmission of all data in *.csv format - Via
USB interface to the PC. Or as an alternative, formatted transfer into Excel via MultiLabImporter
(included in the delivery).
HandyLab
Technical specifications
Measuring
range/
resolution/
accuracy (all
values +/-1 digit)
depending on
the kind of IDS
sensor
pH
0.000 … 14.000 +/-0.004 pH
mV
+/- 1200.0 mV +/- 0.2 mV
Temperature
-5.0 … 105.0 °C +/- 0.2 °C
Calibration
Calibration points
Stored buffers
Calibration memory
Timer
1-, 2-, 3-, 4-, 5-Points
22 preloaded buffer sets
10 last calibrations
1 - 999 Days
Handling
Digital: IDS Sensor
AutoRead
Celsius/Fahrenheit
CMC
QSC
Traceability of results
Display
Data storage
Logger
Interface
Data transfer
Yes for pH and ORP
Automatic/manual
Yes
Yes
Yes
Yes
LCD B/W graphic backlit
Manually 500/automatic 5.000 data sets
Manually/time triggered
Mini USB-B
In *.csv format via USB interface to the PC.
Alternatively also transfer into Excel via
MultiLab Importer (scope of delivery).
4 x 1.5 V AA or 4 x 1.2 V NiMH rechargeable
battery
up to 1,000 h without/ 150 h with backlight
1 x IDS
IP67 (including battery compartment, USB
ports and channels)
Power supply
Continious operating time
Sensor connector
Waterproof
b 600
IDS pH measuring device
easuring accuracy and highest
M
operator comfort without compromise
aterproof design. Sealed
W
keypad (IP67).
to 5 point calibration with 22
1
stored buffer sets
ata storage with output on disD
play and the USB interface
acklit graphic display with clear
B
text menu
Versatile applicationoriented sets
offered
Advantages
HandyLab 600
11
HandyLab 680
The portable IDS hand-held device measures two parameters
simultaneously. ORP, pH, conductivity and oxygen.
The HandyLab 680 increases the measuring The HandyLab 680 increases the operator comfort
accuracy via:
via:
IDS technology - The digitalization of the measu- IDS Technology - the secure allocation of the caliring signal eliminates interferences.
bration data to the sensor eliminates any uncertainty about the date and results of its last calibraAutoRead function - Autoread provides a stabile,
tion. This saves time and money while assuring the
precise measuring value.
highest confidence in your measurements.
CMC (Continuous Measurement Control) - VsuaTraceability of the measuring values - By the
lizes whether the measuring value is within the calidigital and automatic capture of all sensor data.
bration range.
User administration - Can be activated to allow
QSC (Quality Sensor Control) - Informs about the
tiered access and capabilities ensuring security
actual condition of the electrode and therefore
and confidence of your data.
increases operation safety.
Transmission of all data in *.csv format - Via USB
interface to the PC or the USB memory stick, or, as
an alternative, formatted transfer to Excel by means
of MultiLabImporter (included in the delivery).
wo-channel IDS measuring device
T
for pH/mV, conductivity and DO
easuring accuracy and highest
M
operator comfort without compromise
aterproof design. Sealed keypad.
W
(IP67)
to 5 point calibration with 22
1
stored buffer sets
uge data storage with output on
H
display and to the USB interface as
well to the USB memory stick
HandyLab
olor backlit graphic display with
C
clear text menu control
Versatile applicationoriented sets offered
Advanteges
HandyLab 680
12
Technical specifications
Measuring
range/
resolution/
accuracy (all
values +/-1 digit)
depending on
the kind of IDS
sensor
pH
mV
Temperature
Conductivity
Specific resistance
Salinity
TDS
Calibration pH
Calibration cell
constant
conductivity
Temperature
compensation
conductivity
Calibration DO
Handling
DO concentration
DO saturation
DO partial pressure
Calibration points
Stored buffers
Calibration memory
Timer
Fixed
Calibratable (1 point)
Adjustable
Adjustable
Temperature coefficient
Calibration point
Digital: IDS Sensor
AutoRead
Celsius/Fahrenheit
CMC
QSC
User administration
Traceability of results
Display
Data storage
Logger
Interface
Data transfer
0.000 … 14.000 +/-0.004 pH
+/- 1200.0 mV +/- 0.2 mV
-5.0 … 105.0 °C +/- 0.2 °C
0.00 … 2000 mS/cm +/- 0.5 % of mean value
0.00 Ohm cm … 100 MOhm cm +/- 0.5 % of mean
value
0.0 … 70.0 (IOT) +/- 0.5 % of mean value
0 … 1999 mg/l, 0 bis 199.9 g/l +/- 0.5 % of mean
value
0.00 … 20.00 mg/l +/- 0.5 % of value
0.0 …200.0 % +/- 0.5 % of value
0 … 400 hPa +/- 0.5 % of value
1-, 2-, 3-, 4-, 5-Point
22 preprogrammed buffer sets
10 last calibrations
1 - 999 Days
0.475 cm-1, 0.100 cm-1, 0.010 cm-1
0.450 to 0.500 cm-1, 0.800 … 0.880 cm-1,
Standard: 0.01 mol/L KCl
0.250 … 25.000 cm-1; 0,090 … 0.110 cm-1
Automatic/manual
nLF: none linear function according to EN 27 888
and ultrapure water function
Linear compensation 0.000 … 10.000 %/K
No compensation
1 point in FDO check vessel
Yes for pH, ORP, DO and conductivity
Automatic/manual
Yes
Yes
Yes
Yes
Yes
Colored graphic backlit
Manually 500/automatic 10,000 data sets
Manually/time triggered
USB-A and Mini USB-B
In *.csv format via USB interface to the PC or
USB-Memorystick. Alternatively also transfer into
Excel via MultiLab Importer (scope of delivery).
4 x 1.2 V NiMH-rechargeable battery
150h (dependent on connected sensor)
b 680
Power supply
Continious operating
time
Sensor connector
Waterproof
QS
Waterproof
2 x IDS (any combination)
IP67
Good Laboratory Practice (GLP)
IP67 (including battery compartment, USB ports
and channels)
13
HandyLab MKII - Order information
14
Type Number
Order No.
Short Description
HL100Field
285204510 PH-METER Set
HandyLab 100 Field
HL100Routine
285204500
HL100Versatile
285204520
HL200PureWater
285204550
HL200Routine
285204530
HL200Versatile
285204540
HL600Field
285204570
HL600Food
285204630
HL600LifeScience
285204600
HL600Routine
285204560
HL600Science
285204590
HL600Surface
285204610
HL600Tip
285204620
HL600Tris
285204640
HL600TrisMicro
285204650
HL600Versatile
285204580
HL680
CondVersatile
285204760
HL680OxVersatile
285204770
Detailed description
pH-Meter Set HandyLab 100 with pHTcombination electrode BlueLine 24 pH and
protective armouring Z389 for field
applications *
PH-METER Set
pH-Meter Set HandyLab 100 with pHTHandyLab 100 Routine combination electrode BlueLine 14 pH for
routine applications *
PH-METER Set
pH-Meter Set HandyLab 100 with pHTHandyLab 100 Versatile combination electrode A7780-NTC30DIN-N for versatile applications *
COND-METER
Cond-meter set HandyLab 200 with
HandyLab 200 Pure
conductivity cell LF313T for measurements
Water
in purified water *
COND-METER
Cond-meter set HandyLab 200 with
HandyLab 200 Routine conductivity cell LF613T for routine
applications *
COND-METER
Cond-meter set HandyLab 200 with
HandyLab 200 Versatile conductivity cell LF413T for versatile
applications *
PH-METER Set
pH-Meter Set HandyLab 600 with pHTHandyLab 600 Field
combination electrode BlueLine 24 pH IDS
for field applications *
PH-METER Set
pH-Meter Set HandyLab 600 with
HandyLab 600 Food
pH-combination electrode with armoring
BlueLine 21 pH IDS for cut-in measurements
in food applications *
PH-METER Set
pH-Meter Set HandyLab 600 with pHTHandyLab 600 Life
combination electrode A157 IDS for life
Science
science applications *
PH-Meter Set HandyLab pH-Meter Set HandyLab 600 with pHT600 Routine
combination electrode BlueLine 14 pH IDS
for routine applications *
PH-METER Set
pH-Meter Set HandyLab 600 with pHTHandyLab 600 Science combination electrode A162 IDS for
demanding applications *
PH-METER Set
pH-Meter Set HandyLab 600 with pHTHandyLab 600 Surface combination electrode BlueLine 27 pH IDS
for measurement on surfaces *
PH-METER Set
pH-Meter Set HandyLab 600 with pHTHandyLab 600 Tip
combination electrode A6880 IDS for cut-in
measurements *
PH-METER Set
pH-Meter Set HandyLab 600 with pHTHandyLab 600 Tris
combination electrode IL-pHT-A170MF-IDS
for measurement in tris puffer *
PH-METER Set
pH-Meter Set HandyLab 600 with pHTHandyLab 600 Tris
combination electrode IL-Micro-pHT-IDS for
Micro
measurement in tris puffer with smaller
sample volume *
PH-METER Set
pH-Meter Set HandyLab 600 with pHTHandyLab 600 Versatile combination electrode A7780 IDS for
versatile applications *
Cond-METER Set
Cond-meter set HandyLab 680 with
HandyLab 680 Versatile conductivity cell LF413T IDS and Z389
armoring for versatile applications *
OX-METER Set
OX-meter set HandyLab 680 with oxygen
HandyLab 680 Versatile measuring cell FDO1100 IDS and Z389
amoring for versatile applications *
Type Number
Order No.
HL680pH/Cond/
OxVer
285204810 pH/Cond/OX-METER
Set HandyLab 680
Versatile
HL680pH/CondPW 285204780
HL680pH/
CondVersat
285204790
HL680pH/OxVersat 285204800
HL680pHField
285204670
HL680pHFood
285204730
HL680pH
LifeScience
285204700
HL680pHRoutine
285204660
HL680pHScience
285204690
HL680pHSurface
285204710
HL680pHTip
285204720
HL680pHTris
285204740
HL680pHTrisMicro
285204750
HL680pHVersatile
285204680
Z389
285202470
Z530
285202480
Short Description
Detailed description
pH/Cond/OX-meter set HandyLab 680 with
oxygen measuring cell FDO1100 IDS,
conductivity measuring cell LF413T IDS,
pHT-combination electrode A7780 IDS,
Z530 and Z389 for versatile applications *
pH/Cond-METER Set pH/Cond-meter set HandyLab 680 with
HandyLab 680 Pure
conductivity cell LF313T IDS, pHTWater
combination electrode A161 IDS, Z530 and
Z389 for measurements in purified water **
pH/Cond-METER Set pH/Cond-meter set HandyLab 680 with
HandyLab 680 Versatile conductivity cell LF413T IDS, pHTcombination electrode A7780 IDS, Z530
and Z389 for versatile applications **
pH/OX-METER Set
pH/OX-meter set HandyLab 680 with
HandyLab 680 Versatile oxygen measuring cell FDO1100 IDS, pHTcombination electrode A7780 IDS, Z530
and Z389 for versatile applications *
PH-METER Set
pH-Meter Set HandyLab 680 with pHTHandyLab 680 Field
combination electrode BlueLine 24 pH IDS
and Z389 amoring for field applications *
PH-METER Set
pH-Meter Set HandyLab 680 with
HandyLab 680 Food
pH-combination electrode with armoring
BlueLine 21 pH IDS and Z389 for cut-in
measurements in food applications *
PH-METER Set
pH-Meter Set HandyLab 680 with pHTHandyLab 680 Life
combination electrode A157 IDS and Z389
Science
amoring for life science applications *
PH-Meter Set HandyLab pH-Meter Set HandyLab 680 with pHT680 Routine
combination electrode BlueLine 14 pH IDS
and Z389 amoring for routine applications *
PH-METER Set
pH-Meter Set HandyLab 680 with pHTHandyLab 680 Science combination electrode A162 IDS and Z389
amoring for demanding applications *
PH-METER Set
pH-Meter Set HandyLab 680 with pHTHandyLab 680 Surface combination electrode BlueLine 27 pH IDS
and Z389 for measurement on surfaces *
PH-METER Set
pH-Meter Set HandyLab 680 with pHTHandyLab 680 Tip
combination electrode A6880 IDS and Z389
amoring for cut-in measurements *
PH-METER Set
pH-Meter Set HandyLab 680 with pHTHandyLab 680 Tris
combination electrode IL-pHT-A170MF-IDS
and Z389 for measurement in tris puffer *
PH-METER Set
pH-Meter Set HandyLab 680 with pHTHandyLab 680 Tris
combination electrode IL-Micro-pHT-IDS
Micro
and Z389 amoring for measurement in tris
puffer with smaller sample volume *
PH-METER Set
pH-Meter Set HandyLab 680 with pHTHandyLab 680 Versatile combination electrode A7780 IDS and Z389
for versatile applications *
Protective armouring Protective armouring Z389 for HandyLab
Z389
100/200/600/680
Case for multi electrode Case Z530 incl. Z389, buffer and conductivity
storing for HL680
testing solutions for storing several
electrodes and the multi parameter
instrument HandyLab 680
Note:
All sets include a practical case. There are two different cases available, depending on the set.
* Standard case
** Extra large case with the possibility to transport even more electrodes (Z530)
15
IDS Sensors
The intelligent Sensors
When determining the pH value, there are very high
requirements of the sensor and the transmission of
the measuring value from the sensor to the measuring device. The sensitive measuring signals and very
high interior resistors of the sensors require a very
complex shielded signal transfer to the measuring
device in analog systems. If there is moisture present on the contacts, this can change the measuring
value all the way to a complete failure of the measurement. This risk is eliminated by the IDS technology. The measuring value is processed in the sensor, then digitalized and transmitted to the device
without interference.
Storing the calibration data in
the sensor head provides many
advantages for the user outside the
laboratory, especially in connection
with portable devices. For instance,
many samplers carry a number of
sensors with them to cover their
measurement tasks. Contrary to
conventional systems, there is no
longer the need to calibrate the
sensor onsite every time it needs to
be changed.
When the IDS sensors are connected to the measuring device, they automatically identify themselves
with their serial numbers and type designation and
transmit their calibration data to the device. With
conventional systems, the sensor must be calibrated
with every sensor change, as the calibration data is
merely saved in the devices and is only available
with the combination device-sensor. The IDS concept helps here as well due to its calibration, which
is saved in the sensor. Every sensor brings along its
own calibration. There is no mandatory calibration
when the sensor is changed in order to obtain a safe
measurement.
The already proven analog SI Analytics sensors are
used as sensors. The possibility to distinguish
between sensors of the same type by their serial
numbers allows the easy allocation and documentation of electronically recorded and saved measurement results.
16
IDS Senso
ors
he measuring signals are transmitT
ted without interference
Perfect galvanized separation
esistant against environmental
R
influences
llows prognostic maintenance of
A
the sensors by the intelligent sensor evaluation QSC
ffortless allocation and documenE
tation of the sensor to electronically
captured and saved calibration
results
ighest possible operator comfort
H
and measuring accuracy.
Advanteges
IDS Electrodes
17
IDS Electrodes - Order Information
Type No
Order No
Short description
A 157 IDS
285100080
A 161 IDS
285100090
A 162 IDS
285100120
A 6880 IDS
285100100
A 7780 IDS
285101080
BlueLine 14 pH
IDS
285129140
BlueLine 21 pH
IDS
285129210
BlueLine 24 pH
IDS
285129240
pH combination
microelectrode, glass shaft, Pt junction,
electrode A 157 IDS for electrolyte KCl 3 mol/l, Silamid® reference,
Life Science
temp. sensor NTC 30 kOhm, cylindrical
applications
membrane, A glass, 1.5 m fixed cable with
digital plug, length 200 (70/130) mm, 12/5
mm Ø, -5...+100 °C, 0...14 pH
pH combination
glass shaft, Pt junction, electrolyte KCl 3 mol/l,
electrode A 161 IDS for Silamid® reference, temp. sensor NTC 30
demanding
kOhm, sphere membrane, A glass, 1.5 m fixed
applications
cable with digital plug, length 170 mm, 12 mm
Ø, -5...+100 °C, 0...14 pH
pH combination
glass shaft, Pt junction, electrolyte KCl 3 mol/l,
electrode A 162 IDS for Silamid® reference, temp. sensor NTC 30
demanding
kOhm, sphere membrane, A glass, 1.5 m fixed
applications
cable with digital plug, length 120 mm, 12 mm
Ø, -5...+100 °C, 0...14 pH
pH combination
Glass shaft, spear electrode, temp.sensor NTC
electrode A 6880 IDS 30 kOhm, 1.5 m fixed cable with digital plug, 3
with integrated
x ceramic junction, electrolyte KCl 3 mol/l,
temperature sensor for Silamid®-reference system, spear membrane,
cut-in measurements in A-glass, length 120 (70/50) mm, 12/8 mm Ø,
food applications
-5...+80 °C, 0...14 pH
pH combination
Glass shaft, 3 x ceramic junction, gel electrolyte,
electrode A 7780 IDS Silamid®-reference
system,
temperature
for versatile
sensor NTC 30 kOhm, sphere membrane,
applications
A-glass, 1.5 m fixed cable with digital plug,
length 120 mm, 12 mm Ø, -5...+80 °C, 0...14
pH
pH combination
Glass shaft, platinum junction, electr. KCl 3
electrode BlueLine 14 mol/l, Ag/AgCl-reference system, temp.pH IDS for routine
sensor NTC 30 kOhm, cone membrane,
applications
A-glass, 1.5 m fixed cable with digital plug,
length 120 mm, 12 mm Ø, -5...+100° C, 0...14
pH
pH combination
Plastic shaft, hole-junction, Referid® electrolyte,
electrode BlueLine 21 Ag/AgCl-reference system, spear membrane,
pH IDS for cut-in
A-glass, 1.5 m fixed cable with digital plug,
measurements in food length 90 (65/25) mm, 12/5 mm Ø, -5...+80 °C,
applications
2...13 pH
pH combination
Plastic shaft, fibre-junction, gel electrolyte, Ag/
electrode BlueLine 24 AgCl-reference system, temp.-sensor NTC 30
pH IDS for field
kOhm, cylinder membrane, A glass, 1.5 m
applications
fixed cable with digital plug, length 120 mm,
12 mm Ø, -5...+80 °C, 0...14 pH
pH combination
Plastic shaft, fibre-junction, gel electrolyte, Ag/
electrode BlueLine
AgCl-reference system, temp.-sensor NTC 30
24-3 pH IDS for field kOhm, cylinder membrane, A glass, 3 m fixed
applications
cable with digital plug, length 120 mm, 12 mm
Ø, -5...+80 °C, 0...14 pH
pH combination
Glass
shaft,
KPG-annular-gap-junction,
electrode BlueLine 27 Referid®
electrolyte,
Ag/AgCl-reference
pH IDS for surface
system, temp.-sensor NTC 30 kOhm, flat
measurements
membrane, L glass, 1.5 m fixed cable with
digital plug, length120 mm, 12 mm Ø, -5...+50
°C, 2...13 pH
ORP combination
Glass shaft, ceramic junction, electrolyte KCl 3
electrode BlueLine 31 mol/l, Ag/AgCl-reference system,
temp.RX IDS for routine
sensor NTC 30 kOhm, sensor platinum disk 4
applications
mm Ø, 1.5 m fixed cable with digital plug,
length 120 mm, 12 mm Ø, -5...+100 °C
BlueLine 24-3 pH 285129243
IDS
18
BlueLine 27 pH
IDS
285129270
BlueLine 31 RX
IDS
285129310
Detailed description
Type No
Order No
Short description
BlueLine 32 RX
IDS
285129321
ORP combination
electrode BlueLine 32
RX IDS for field
applications
BlueLine 32-3 RX 285129323
IDS
FDO11003MIDS 285202450
FDO1100IDS
285202440
IL-Micro-pHT-IDS 285100150
IL-pHT-A120MF- 285100130
IDS
IL-pHT-A170MF- 285100140
IDS
IL-Sp-pHT-IDS
285100160
LF313TIDS
285202430
LF413T3MIDS
285202420
LF413TIDS
285202410
OX930
285202460
Detailed description
Plastic shaft, fibre-junction, gel electrolyte, Ag/
AgCl-reference system, temp.-sensor NTC 30
kOhm, sensor platinum pin 1 mm Ø, 1.5 m
fixed cable with digital plug, length 120 mm,
12 mm Ø, -5...+80 °C
ORP combination
Plastic shaft, fibre-junction, gel electrolyte, Ag/
electrode BlueLine
AgCl-reference system, temp.-sensor NTC 30
32-3 RX IDS for on-site kOhm, sensor platinum pin 1 mm Ø, 3 m fixed
applications
cable with digital plug, length 120 mm, 12 mm
Ø, -5...+80 °C
Optical oxygen
IDS®
optical
oxygen
sensor
measuring electrode (photoluminescence),
plastic
shaft,
FDO 1100 3M IDS for temperature sensor NTC30kOhm, 3 m fixed
versatile applications cable with digital plug, length 150 mm, 15.3
mm Ø, 0...+50 °C
Optical oxygen
IDS®
optical
oxygen
sensor
measuring electrode (photoluminescence),
plastic
shaft,
FDO 1100 IDS for
temperature sensor NTC30kOhm, 1.5 m fixed
versatile applications cable with digital plug, length 150 mm, 15.3
mm Ø, 0...+50 °C
pH combination
Glass shaft, micro electrode, temp. sensor
electrode IL-Micro-pHT-NTC 30 kOhm, 1.5 m fixed cable with digital
IDS for measurements plug, Pt junction, electrolyte KCl 3 mol/l,
in tris buffer or protein- Iodine/Iodide-reference system, cylindrical
containing samples
membrane, A glass, length 200 (70/130) mm,
with low volume
12/5 mm Ø, -5...+100 °C, 0...14 pH
pH combination
Glass shaft, temp. sensor NTC 30 kOhm, 1.5 m
electrode IL-pHTfixed cable with digital plug, Pt junction,
A120MF-IDS for
electrolyte KCl 3 mol/l, Iodine/Iodidemeasurements in tris reference system, sphere membrane, A-glass,
buffer or proteinlength 120 mm, 12 mm Ø, -5...+100 °C, 0...14
containing samples
pH
pH combination
Glass shaft, temp. sensor NTC 30 kOhm, 1.5 m
electrode IL-pHTfixed cable with digital plug, Pt junction,
A170MF-IDS for
electrolyte KCl 3 mol/l, Iodine/Iodidemeasurements in tris reference system, sphere membrane, A-glass,
buffer or proteinlength 170 mm, 12 mm Ø, -5...+100 °C, 0...14
containing samples
pH
pH combination
Glass shaft, spear electrode, temp.sensor NTC
electrode IL-Sp-pHT- 30 kOhm, 1.5 m fixed cable with digital plug, 3
IDS with integrated
x ceramic junction, electrolyte KCl 3 mol/l,
temperature sensor for Iodine/Iodide-reference
system, A-glass,
cut-in measurements in length 120 (70/50) mm, 12/8 mm Ø, -5...+100
protein-containing
°C, 0...14 pH
food applications
Conductivity cell
IDS® Ultrapure water cond. cell including flow
LF313T IDS for
through device, stainless steel shaft, 1.5 m
measurements in pure cable with digital plug, sensor stainless steel,
water
cell constant 0.1 cm-1, temp.-sensor NTC 30
kOhm, length 120 mm, 12 mm Ø, -5...+80 °C
Conductivity cell
IDS® 4 pole cell, plastic shaft, 3 m cable with
LF413T 3M IDS for
digital plug, sensor material graphite, cell
versatile applications constant 0.475 cm-1, temp.-sensor NTC 30
kOhm, length 120 mm, 15.3 mm Ø, -5...+80 °C
Conductivity
IDS® 4 pole cell, plastic shaft, 1.5 m cable with
measuring cell LF413T digital plug, sensor material graphite, cell
IDS for versatile
constant 0.475 cm-1, temp.-sensor NTC 30
applications
kOhm, length 120 mm, 15.3 mm Ø, -5...+80 °C
Exchange head OX 930Exchange head OX 930 for oxygen sensor
FDO 1100 IDS
19
IDS Sensors - Application overview
Application
area
Sample type
Type
Application Range
pH micro cylinder + Temp.
`-5..100°C; pH 0-14
pH sphere + Temp.
´+10..100°C; pH
0-14
A 6880 IDS
pH spear + Temp.
`-5..100°C; pH 0-14
A 7780 IDS
pH sphere + Temp.
`-5..80°C; pH 0-14
BL 14 pH IDS
pH cone + Temp.
`-5..100°C; pH 0-14
BL 21 pH IDS
pH spear
`-5..80°C; pH 2-13
BL 24/
24-3 pH IDS
pH cylinder
`-5..80°C; pH 0-14
BL 27 pH IDS
pH flat
`-5..50°C; pH 2-13
BL 31 RX IDS
ORP platinum disk, 4mm Ø +
Temp.
´-5..100°C
BL 32/
32-3 RX IDS
ORP platinum pin, 1 mm Ø +
Temp.
´-5..80°C
FDO 1100/
1100 3M IDS
oxygen optical
(photoluminiscence) + Temp.
0.. 50°C
A 157 IDS
A 161/
162 IDS
IL-Micro-pHTIDS
IL-pHT-A120/
170 MF-IDS
IL-Sp-pHT-IDS
LF313T IDS
LF 413T/
413T 3M IDS
20
Measuring Function
Construction
Pt Junct., Electr. KCl 3 mol/l, Silamid® Ref., Temp.
Sensor NTC 30 kOhm, A Glass, 1.5 m fixed cable,
length 200 (70/130) mm, 12/5 mm Ø
Pt Junct., Electr. KCl 3 mol/l, Silamid® Ref., Temp.
Sensor NTC 30 kOhm, A Glass, 1.5 m fixed cable,
length 120 (A162) mm/ 170 mm (A161), 12 mm Ø
3 x Ceramic Junct., Electr. KCl 3 mol/l, Silamid® Ref.,
Temp. Sensor NTC 30 kOhm, 1.5 m fixed cable, A
Glass, length 120 (70/50) mm, 12/8 mm Ø
3 x Ceramic Junct., Gel Electr., Silamid®-Ref., Temp.
Sensor NTC 30 kOhm, A Glass, 1.5 m fixed cable,
length 120 mm, 12 mm Ø
Pt Junct., Electr. KCl 3 mol/l, Ag/AgCl-Ref., Temp.
Sensor NTC 30 kOhm, A Glass, 1.5 m fixed cable,
length 120 mm, 12 mm Ø
Plastic shaft, hole Junct., Referid® Electr., Ag/AgClRef., A Glass, 1.5 m fixed cable, length 90 (65/25)
mm, 12/5 mm Ø
Plastic shaft, fibre Junct., Gel Electr., Ag/AgCl-Ref.,
Temp. Sensor NTC 30 kOhm, A Glass, 1.5 m/3 m
fixed cable, length 120 mm, 12 mm Ø
KPG-annular gap Junct., Referid® Electr., Ag/AgClRef., Temp. Sensor NTC 30 kOhm, L Glass, 1.5 m
fixed cable, length 120 mm, 12 mm Ø
Ceramic Junct., Electr. KCl 3 mol/l, Ag/AgCl-Ref.,
Temp. Sensor NTC 30 kOhm, 1.5 m fixed cable,
length 120 mm, 12 mm Ø
Plastic shaft, fibre Junct., Gel Electr., Ag/AgCl-Ref.,
Temp. Sensor NTC 30 kOhm, 1.5 m/3 m fixed cable,
length 120 mm, 12 mm Ø
Plastic shaft, Temperatursensor NTC30kOhm, 1.5
m/3 m fixed cable, length 150 mm, 15.3 mm Ø
Pt Junct., Electr. KCl 3 mol/l, Iodine/Iodide-Ref., A
´-5..100°C; pH 0..14 Glass, Temp. Sensor NTC 30 kOhm, 1.5 m fixed
cable, length 200 (70/130) mm, 12/5 mm Ø,
Pt Junct., Electr. KCl 3 mol/l, Iodine/Iodide-Ref.,
´-5..100°C; pH 0..14 A-Glass, Temp. Sensor NTC 30 kOhm, 1.5 m fixed
pH sphere + Temp.
cable, length 120 mm/170 mm, 12 mm Ø
3 x Ceramic Junct., Electr. KCl 3 mol/l, Iodine/Iodide´-5..100°C; pH 0..14 Ref., A-Glass, Temp. Sensor NTC 30 kOhm, 1.5 m
pH spear + Temp.
fixed cable, length 120 (70/50) mm, 12/8 mm Ø
Cond. cell including flow through device, 1.5 m
conductivity stainless steel + ´-5..80°C; 0..0.2 mS/ fixed cable, cell const. 0.1 cm-1, Temp. Sensor NTC
cm
Temp.
30 kOhm, length 120 mm, 12 mm Ø
4 pole cond cell, Plastic shaft, 1.5 m /3 m fixed cable,
´-5..80°C; 1..2000
cell const. 0.475 cm-1, Temp. Sensor NTC 30 kOhm,
conductivity graphite + Temp.
mS/cm
length 120 mm, 15,3 mm Ø
pH micro cylinder + Temp.















































































































































21
Ground (extract/slug)
Fertilizer solution
Vegetables
Beer
Lemonades/soda
Mineral water
Juice
Spirits
Wine
Etching and degreasing baths
Dispersion paint
Emulsions, partly water-based
Paint/varnish, water-soluble
Fixing bath
Varnish, partly water-based
Lye, extreme
Organic percentile high
Paper extract
Sulphide containing liquid
Suspension, water-based
Viscose samples
General purpose
Emulsions - cosmetics, oil
Butter
Yoghurt
Cheese
Milk
Cream
Economic
General purpose
Research Grade
Stream
Ground water
Lake water
Seawater
Rain water
Bread/dough/pastry
Vinegar
Fish
Meat
Honey
Margarine
Jam/marmelade
Mayonnaise
Sausage
General purpose
High ionic strength - extrem pH
Titration
Harsh enviroment, rugged use
Low maintainance
Non-aqueous - solvents, alcohols
Agar-agar gel
Enzyme solution
Small vessels/sample quantitiy
Bacteria cultures
Precision measurement
Protein containing liquid
Serum
Tris Buffer
Skin
Leather
Paper
Textiles
Waste water, general
Demineralization/ion exchanger
Condensate
Purity water
Salt solution
Drinking water
Drops
Water
Surface
Pharmacy, biology,
biotechnology, medicine,
microbiology
General Laboratory
Food production
Field measurements
Education
Dairy
Cosmetics
Chemistry
Bewerage
Agriculture
Our company name - SI Analytics - already expresses our core competency - the
manufacturing of analysis equipment. Furthermore, SI stands for the main products
of our company: Sensors and Instruments.
We have risen from the history of SCHOTT® AG and SI Analytics can offer 75 years of
experience in glass technology and the development of analysis equipment. We will
continue to develop and manufacture our products with the highest requirements of
innovation and quality.
Only the name will change - the quality will remain!
We have been an independent enterprise for over 40 years, and as a former subsidiary
of SCHOTT® AG, we continue to value tradition and manufacture in the footsteps of
traditional Mainz glass manufacturers.
Our electrodes, meters, titrators and capillary viscosimeters will continue to have
their home in areas, where the know-how in analytic measurement technology is in
demand.
SI Analytics has been part of the listed company Xylem Inc. since 2011, which is
headquartered in Rye Brook / N.Y., USA. Xylem is a leading worldwide provider of
problem solutions regarding water.
22
We are Xylem Analytics
Xylem consists of three business sectors - Water Solutions, Applied Water Systems and Analytics.
The following companies make up Xylem Analytics and act like SI Analytics in the chemical,
pharmaceutical, biotechnological, food and plastics industries.
Bellingham & Stanley
For almost a century, Bellingham + Stanley has
been the leader in the field of:
• Refractometers
• Polarimeters
• Certified Reference Materials
www.bellinghamandstanley.com
ebro
ebro has been servicing the scientific world with innovative
temperature measurement solutions for over forty years and today,
customer feedback still plays an important role within the business model.
To ebro, customer care not only means supporting existing product
and software; it also means being able to provide custom solutions
within their field of excellence too!
• Precision thermometers
• Food Safety test kits
• Frying oil monitors
• Humidity, vacuum & temperature dataloggers
• Portable digital refractometers
www.ebro.com
OI Analytical
Since 1963 OI Analytical has been providing innovative products
used for chemical analysis and is a key supplier of sample
preparation and turn-key analytical solutions for testing food
products and water for chemical contaminants.
Beverage & water analyses include the determination of:
• Total Organic Carbon (TOC) & cyanide
• Organophosphorus & organochlorine pesticides
• Volatile Organic Compounds (VOCs)
Sample preparation for food and fruit analyses include:
• Antibiotics & mycotoxins
• Organophosphorus pesticides
• Organochlorine pesticides
www.oico.com
Furthermore, Xylem Analytics comprises:
23
What can Xylem do for you?
We’re 12,700 people unified in a common purpose: creating innovative solutions
to meet our world’s water needs. Developing new technologies that will improve
the way water is used, conserved, and re-used in the future is central to our work.
We move, treat, analyze, and return water to the environment, and we help people
use water efficiently, in their homes, buildings, factories and farms. In more than
150 countries, we have strong, long-standing relationships with customers who
know us for our powerful combination of leading product brands and applications
expertise, backed by a legacy of innovation.
For more information on how Xylem can help you, go to www.xyleminc.com
SI Analytics GmbH
Hattenbergstr. 10
55122 Mainz
Germany
Phone: +49 6131 66 5111
Fax:
+49 6131 66 5001
E-Mail:si-analytics@xyleminc.com
Internet:www.si-analytics.com
presented by
SI Analytics is a trademark of Xylem Inc. or one of its subsidiaries.
© 2015 Xylem, Inc.
980 082 US
Version 01/2015