KSR Magnetostrictive Level Transmitters (High Accuracy)
Transcription
KSR Magnetostrictive Level Transmitters (High Accuracy)
KSR Magnetostrictive Level Transmitters (High Accuracy) 1012-1 KSR KUEBLER Niveau-Messtechnik AG 69439 Zwingenberg Germany Tel ++49 (0) 62 63 - 87- 0 Fax ++49 (0) 62 63 - 87 99 info@ksr-kuebler.com www.ksr-kuebler.com 1012-1 KUBLER FRANCE S.A. 68700 Cernay KSR KUEBLER (UK) Level Measurement & Control Ltd. Corwen, Denbigshire LL21 9PU KSR KUEBLER (Scandinavia) 2970 Hoersholm KSR KUEBLER (Italy) Misura di Livello 24030 Brembate S.(BG) KSR H&H Measurement BV (benelux) 5133 NE, Riel OOO KSR KUEBLER RUS (RUS) 109428 Moskau KSR KUEBLER (USA) Level Control Products of America Inc. Charlotte, NC 28273 KSR KUEBLER (SINGAPORE) Level Measurement & Control Pte. Ltd. Singapore 608609 SHANGHAI KSR KUEBLER Automation Instruments Co. Ltd. Shanghai / China Approvals Contents ATEX 94/9/EC PED 97/23/EC KSR Magnetostrictive Level Transmitters Description 4 Germany Technischer Überwachungsverein Südwestdeutschland e.V. Type code 5 IBExU Institut für Sicherheitstechnik GmbH KSR Magnetostrictive Level Transmitters Physikalisch Technische Bundesanstalt PTB Stainless steel 1.4571 (316Ti) 6 Food Industry - Design 7 Pharmaceutical Design 8 PVC, Polypropylene, PVDF 9 Stainless steel E-CTFE-coated 10 France Laboratoire Central des Industries Electriques Stainless steel PTFE-lined 10 Magnetic Level Gauge / Bypass - Design 11 Bureau Veritas Float designs 12 Denmark DEMKO Length limitations for FFG-...-Ex 13 KSR KUEBLER Quality 14 Bundesamt für Wehrtechnik und Beschaffung Germanischer Lloyd Netherlands KEMA Norway Det Norske Veritas 1012-1 Russia Gosgortechnadzor OGS Oil & Gas Safety GOST Permission to use Pattern Approval/EX USA Factory Mutual Research Corporation KSR Magnetostrictive Level Transmitters KSR Magnetostrictive Level Transmitters Type FFG-T-... are used for continuous, remote liquid level measurement and based on position monitoring of a magnetic float following the magnetostrictive principle. Technical advantages The measuring process is initiated by a current impulse. This current generates an axial magnetic field (3) along the length of a wire (1) made of magnetostrictive material, which is held under tension inside the guide tube. The float, which sits on the liquid surface, is fitted with permanent magnets (4). When the pulse reaches the float the two magnetic fields interact and a torsional force results. Constant measurement of liquid levels, independent of physical and chemical changes of the medium, such as: foaming, conductivity, dielectric constant, pressure, vacuum, temperature, vapours, condensation, bubbles, boiling effects, S.G. changes. A torsional stress wave (5) is induced in the wire. A piezoceramic converter in the transmitter housing (2) at the end of the wire converts this into an electrical signal. By measuring the elapsed transit time, it is possible to determine the start point of the torsional stress wave and therefore the float position with a high degree of accuracy. The simple and effective principle of operation makes these devices ideally suited for a plethora of applications. Signal transmission over long distances. Simple installation and commissioning - oneoff initial calibration adjustment, no further calibration necessary. Interface and total level measurement at ∆-S.G. ≥ 50 kg / m3. Application limits: T = –200 °C to +200 °C P = vacuum to 100 bar ρ ≥ 400 kg/m3 Availability of many corrosion resistant materials facilitates use in applications in all industry sectors: chemical, petrochemical, oil and gas, pharmaceutical, off-shore, ship building, power plants, manufacturing, water treatment, food and beverages. 1012-1 Application specific designs and solutions available. Explosion-proof designs. ¡ ➀ ➂ ➄ ➃ ➄ ➀ Wire ➁ Electronics housing ➂ Magnetic field ➃ Magnet ➄ Torsional wave KSR Magnetostrictive Level Transmitters Type code Code 1 FFG 2 Basic type T 3 Transmitter Housing Transmitter housing stainless steel Process connection Material (Process connection) .../... R Mounting thread downwards (DIN/BSP) NPT Mounting thread downwards (NPT) MR Dairy pipe fitting to DIN 11851 F Flange (DIN, ANSI or JIS) FC Clamp-connection to DIN 32676 (Triclamp) IS Sanitary nozzle (Ingold nozzle) V VE VEC VTF T HB HC P PP PF Stainless steel 1.4571 (316Ti) Stainless steel electropolished Stainless steel E-CTFE-coated Stainless steel PTFE-lined Titanium Hastelloy B Hastelloy C PVC Polypropylene PVDF 4 Size process connection .../.../... ... Mounting thread size in inches ... Dairy pipe fitting size DN 50 – DN 150 .../ DIN ANSI JIS Clamp Flange nominal size .../ DN 50 - DN 200 2”- 8” 3 /8”(DN 10) - 4”(DN 100) DN 25 - DN 100; 1”- 4” 5 Guide tube (sensor tube) material ... 6 .../.../... V VE VEC VTF T 4 HB HC P PP PF Stainless steel 1.4571 (316Ti) Stainless steel electropolished Stainless steel E-CTFE-coated Stainless steel PTFE-lined Titanium Guide tube length L.../ Length in mm Float design (Page 12) .../... .../ Material (Code 5) 8 Approvals ... Ex Ex-Design ... Measuring range 1012-1 Diameter ... Tube OD Float OD in mm Type code example: Basic- Transmitter Connection Connection Guide tube Type housing Material Size Material Code Flange face Standard Form C optional E,A,F,N Standard RF optional RTJ,FF,ST,SG Standard RF optional RTJ,FF,ST,SG Hastelloy B Hastelloy C PVC Polypropylene PVDF M.../ Range in mm 7 Flange pressure rating ... PN 6 - PN 100 Class 150 - 600 5 K- 63 K 4 Guide tube length Measuring range Tube OD Float Approval 1 - 2 - 3 - - 5 - 6 - 7 - 8 FFG - T - FV - 50/6/F - V - L950/M850/12 - V44A - Ex KSR Magnetostrictive Level Transmitters Stainless steel 1.4571 (316Ti) II 1/2G EEx ia IIC T6-T3 IBExU 02 ATEX 1124 X OD 52 OD 52 Cable gland M16x1,5 Cable gland M16x1,5 Stainless steel transmitter housing Material 1.4301 Ingress protection IP68 U U Stainless steel transmitter housing Material 1.4301 Ingress protection IP68 120 Type code Ex only: 120 WAF 30 or WAF 36 100 % level Guide tube OD 12 or OD 18 Float Float OD 1012-1 FFG-T-RV...-V-L.../M.../..-V..A (-Ex) Mounting flange Guide tube length L = ... Measuring range L 1 = ... M=… Guide tube length L = ... Measuring range L 1 = ... M =… BSP 11/2˝ or BSP 2˝ 100 % level Guide tube OD 12 or OD 18 Float Float OD FFG-T-FV/.../...-V-L.../M.../..-V..A (-Ex) Electrical connection Transmitter housing stainless steel 1.4301, Ingress protection IP68 Process connection Mounting thread Flange BSP 11/2“ or BSP 2“ to DIN: DN50 - DN200 , PN6 - PN100 to ANSI: 2“ - 8“ , Class 150 - 600 Guide tube OD 12 mm 18 mm 12 mm 18 mm Guide tube length max. 3000 mm 6000 mm 3000 mm 6000 mm Float V44A, V52A, V62A, V83A Guide tube OD 12 mm V80A, V98A, V105A, V120A Guide tube OD 18 mm Limit S.G. 85% Nominal S.G. 50% see page 12 (float designs) Nominal pressure see page 12 (float designs) Temperature range Liquid -45°C ...+125°C Standard design Liquid -200°C ...+200°C HT design Transmitter housing -40°C ... +85°C Ex-Design Category 1/2 Liquid Transmitter housing T6 -25°C ... +85°C -40°C ... +40°C T5 -25°C ... +100°C -40°C ... +55°C T4 -25°C ... +135°C -40°C ... +85°C T3 -25°C ... +150°C -40°C ... +85°C Connection 2-wire Supply voltage 10 ... 30 VDC Output signal 4 ... 20 mA Permissible circuit values Type of protection intrinsically safe EEx ib IIC Ui < 30 V ; Ii < 200 mA ; Li < 250 µH ; Ci < 5 nF Error signal Adjustable to 3.6 mA or 21.5 mA Accuracy / linearity Better ±0.5 mm Resolution < 0.1 mm Analogue section ± 0.1 % (20°C) + 0.005 % / K Load 900 Ohm at UB = 30V DC ; 650 Ohm at UB = 24V DC ; 100 Ohm at UB = 12V DC KSR Magnetostrictive Level Transmitters Food Industry Design Stainless steel 1.4404, 1.4435 (316L) II 1/2G EEx ia IIC T6-T3 IBExU 02 ATEX 1124 X OD 52 OD 52 Cable gland M16x1,5 Cable gland M16x1,5 Stainless steel transmitter housing Material 1.4301 Ingress protection IP68 U U Stainless steel transmitter housing Material 1.4301 Ingress protection IP68 120 Type code Ex only: 120 100 % level Guide tube Float Float OD Guide tube length L = ... Measuring range M=… L 1 = ... Guide tube length L = ... Measuring range L 1 = ... M=… Dairy pipe fitting to DIN 11 851 Mounting Flange / Clamp Connection 100 % level Guide tube Float Float OD FFG-T-MRVE...-VE-L.../M.../..-VE..A (-Ex) FFG-T-FCVE/...-VE-L.../M.../..-VE..A (-Ex) Electrical connection Process connection Guide tube OD Guide tube length max. Float Limit S.G. 85% Nominal S.G. 50% Nominal pressure Temperature range Ex-Design Connection Supply voltage Output signal Permissible circuit values Error signal Accuracy / linearity Resolution Analogue section Load Transmitter housing stainless steel 1.4301, Ingress protection IP68 Dairy pipe fitting to DIN 11851 Clamp-connection to DIN 32676 (Triclamp) DN50 - DN150 DN25 - DN100 or 1“ - 4“ 12 mm 18 mm 12 mm 18 mm 3000 mm 6000 mm 3000 mm 6000 mm V44A, V52A, V62A, V83A Guide tube OD 12 mm V80A, V98A, V105A, V120A Guide tube OD 18 mm 1012-1 see page 12 (float designs) see page 12 (float designs) Liquid -45°C ...+125°C Standard design Liquid -200°C ...+200°C HT design Transmitter housing-40°C ... +85°C Category 1/2 Liquid Transmitter housing T6 -25°C ... +85°C -40°C ... +40°C T5 -25°C ... +100°C -40°C ... +55°C T4 -25°C ... +135°C -40°C ... +85°C T3 -25°C ... +150°C -40°C ... +85°C 2-wire 10 ... 30 VDC 4 ... 20 mA Type of protection intrinsically safe EEx ib IIC Ui < 30 V ; Ii < 200 mA ; Li < 250 µH ; Ci < 5 nF Adjustable to 3.6 mA or 21.5 mA Better ±0.5 mm < 0.1 mm ± 0.1 % (20°C) + 0.005 % / K 900 Ohm at UB = 30V DC ; 650 Ohm at UB = 24V DC ; 100 Ohm at UB = 12V DC KSR Magnetostrictive Level Transmitters OD 52 Pharmaceutical Design Stainless steel 1.4435 (316L) and 1.4539 II 1/2G EEx ia IIC T6-T3 IBExU 02 ATEX 1124 X 120 Type code Ex only: Stainless steel transmitter housing Material 1.4301 Ingress protection IP68 U Cable gland M16x1,5 L 1 = ... Sanitary Ingold nozzle with union nut and O-ring Guide tube length L = ... Measuring range M=… Guide tube 100 % level Float Float OD 1012-1 FFG-T-IS-V-L.../M.../17,2-V80/88R4/3A/35 (-Ex) FFG-T-IS-V-L.../M.../17,2-V80R/4V/39 (-Ex) Electrical connection Process connection Guide tube OD Guide tube length max. Float Limit S.G. 85% Nominal S.G. 50% Nominal pressure Temperature range Ex-Design Connection Supply voltage Output signal Permissible circuit values Error signal Accuracy / linearity Resolution Analogue section Load Transmitter housing stainless steel 1.4301, Ingress protection IP68 IS = Sanitary nozzle (Ingold nozzle) MR= Dairy pipe fitting DIN 11851 or other sanitary FC= Clamp-connection (Triclamp) F = Flange (DIN, ANSI, JIS) fittings 17.2 mm Stainless steel 1.4435 or 1.4539, ground and polished, Ra <0.4 6000 mm V80/88R4/3A/35 Stainless steel 1.4435, ground and polished, Ra <0.4 V80R/4V/39 Stainless steel 1.4539, electropolished 715 kg/m3 1220 kg/m3 10 bar Liquid -45°C ... +125°C Standard design Liquid -200°C ... +200°C HT design Transmitter housing -40°C ... +85°C Category 1/2 Liquid Transmitter housing T6 -25°C ... +85°C -40°C ... +40°C T5 -25°C ... +100°C -40°C ... +55°C T4 -25°C ... +135°C -40°C ... +85°C T3 -25°C ... +150°C -40°C ... +85°C 2-wire 10 ... 30 VDC 4 ... 20 mA Type of protection intrinsically safe EEx ib IIC Ui < 30 V ; Ii < 200 mA ; Li < 250 µH ; Ci < 5 nF Adjustable to 3.6 mA or 21.5 mA Better ±0.5 mm < 0.1 mm ± 0.1 % (20°C) + 0.005 % / K 900 Ohm at UB = 30V DC ; 650 Ohm at UB = 24V DC ; 100 Ohm at UB = 12V DC KSR Magnetostrictive Level Transmitters PVC, Polypropylene, PVDF OD 52 OD 52 Cable gland M16x1,5 Stainless steel transmitter housing Material 1.4301 Ingress protection IP68 U U Stainless steel transmitter housing Material 1.4301 Ingress protection IP68 120 120 Cable gland M16x1,5 WAF 36 100 % level Guide tube OD 20 Float Float OD PVC Polypropylene PVDF FFG-T-RP...-P-L.../M.../..-P..A FFG-T-RPP...-PP-L.../M.../..-PP..A FFG-T-RPF...-PF-L.../M.../..-PF..A Mounting flange Guide tube length L = ... Measuring range L 1 = ... M=… Guide tube length L = ... Measuring range L 1 = ... M=… BSP 2˝ 100 % level Guide tube OD 20 Float Float OD FFG-T-FP/.../...-P-L.../M.../..-P..A FFG-T-FPP/.../...-PP-L.../M.../..-PP..A FFG-T-FPF/.../...-PF-L.../M.../..-PF..A 1012-1 Electrical connection Transmitter housing stainless steel 1.4301, Ingress protection IP68 Process connection Mounting thread Mounting flange BSP 2“ to DIN: DN65 - DN125 , PN10 Form to ANSI: 21/2“ - 5“ , Class 150 FF Guide tube OD 20 mm Guide tube length max. 5000 mm Float PVC P55A/26 or P80A Polypropylene PP55A/26 or PP80A PVDF PF55A/26 or PF80A Limit S.G. 85% see page 12 (float designs) Nominal S.G. 50% Nominal pressure max. 3 bar Temperature range Liquid 0°C ... +60°C PVC -10°C ... +80°C Polypropylene -10°C ...+100°C PVDF Transmitter housing -40°C ... +85°C Connection 2-wire Supply voltage 10 ... 30 VDC Output signal 4 ... 20 mA Error signal Adjustable to 3.6 mA or 21.5 mA Accuracy / linearity Better ±0.5 mm Resolution < 0.1 mm Analogue section ± 0.1 % (20°C) + 0.005 % / K Load 900 Ohm at UB = 30V DC ; 650 Ohm at UB = 24V DC ; 100 Ohm at UB = 12V DC KSR Magnetostrictive Level Transmitters Stainless steel ECTFE-coated and PTFE-lined OD 52 OD 52 Option: anti-static Stainless steel transmitter housing Material 1.4301 Ingress protection IP68 U U Stainless steel transmitter housing Material 1.4301 Ingress protection IP68 Cable gland M16x1,5 120 120 Cable gland M16x1,5 L 1 = ... Mounting flange Guide tube Float Float OD 100 % level Guide tube length L = ... Measuring range M=… 100 % level Measuring range M=… Guide tube length L = ... L 1 = ... Mounting flange Guide tube Float Float OD 1012-1 10 FFG-T-FVEC/.../…-VEC-L.../M.../18-VEC..A Electrical connection Process connection Guide tube OD Guide tube length max. Float Limit S.G. 85% Nominal S.G. 50% Nominal pressure Temperature range Connection Supply voltage Output signal Error signal Accuracy / linearity Resolution Analogue section Load Transmitter housing stainless steel 1.4301, Ingress protection IP68 Mounting flange to DIN DN50 - DN200 , PN6 - PN100 or to ANSI 2“ - 8“ , Class 150 - 600 18 mm 25 mm, PTFE-Sleeve = 3.5 mm thick 4000 mm 5000 mm VEC81A, VEC99A, VEC106A, VEC121A TF80A, TF90A see page 12 (float designs) FFG-T-FVTF/.../...-VTF--L.../M.../25-TF..A see page 12 (float designs) max. 3 bar Process dep. on liquid Transmitter housing -40°C ... +85°C 2-wire 10 ... 30 VDC 4 ... 20 mA Adjustable to 3.6 mA or 21.5 mA Better ±0.5 mm < 0.1 mm ± 0.1 % (20°C) + 0.005 % / K 900 Ohm at UB = 30V DC ; 650 Ohm at UB = 24V DC ; 100 Ohm at UB = 12V DC KSR Magnetostrictive Level Transmitters Magnetic Level Gauge / Bypass Design Type code Ex only II 2G EEx ib IIC T6-T3 IBExU 02 ATEX 1124 X 120 30 Measuring range M… L 50 1012-1 FFG-BT-V-L.../M.../12 (-Ex) Electrical connection Transmitter housing stainless steel 1.4301, Ingress protection IP68 Sensor tube OD OD 12 mm Sensor length 200 mm ... 6000 mm Permissible ambient temperature Sensor tube -45°C ... +125°C Standard design Sensor tube -200°C ... +200°C HT design Transmitter housing -40°C ... +85°C Ex-Design Category 2 Sensor tube Transmitter housing T6 -25°C ... +85°C -40°C ... +40°C T5 -25°C ... +100°C -40°C ... +55°C T4 -25°C ... +135°C -40°C ... +85°C T3 -25°C ... +150°C -40°C ... +85°C Connection 2-wire Supply voltage 10 ... 30 VDC Output signal 4 ... 20 mA Permissible circuit values Type of protection intrinsically safe EEx ib IIC Ui < 30 V ; Ii < 200 mA ; Li < 250 µH ; Ci < 5 nF Error signal Adjustable to 3.6 mA or 21.5 mA Accuracy / linearity Better ±0.5 mm Resolution < 0.1 mm Analogue section ± 0.1 % (20°C) + 0.005 % / K Load 900 Ohm at UB = 30V DC ; 650 Ohm at UB = 24V DC ; 100 Ohm at UB = 12V DC 11 KSR Magnetostrictive Level Transmitters Spherical floats (S) Cylindrical floats (C) OD C OD C D D D = Limit S.G. E B E at 85% immersed float volume B E = Nominal S.G. at 50% immersed float volume Material Type Shape A B C Max. Max. Weight Volume Code 6 OD OD operating operating temp. [mm] [mm] [mm] pressure [bar] [°C] [g] [cm3] Limit S.G. Nominal S.G. 85% 50% [kg/m3] [kg/m3] OD A 1012-1 12 Stainless Steel Titanium Stainless Steel E-CTFE- coated PVC Polypropylene PVDF PTFE V44A V52A V62A V83A V80A V98A V105A V120A V120A/38 T44A T52A T52A/0,6 T52A/0,8 T62A T83A T80A T98A T105A T120A VEC81A VEC99A VEC106A VEC121A P55A P55A/26 P80A PP55A PP55A/26 PP80A PF55A PF55A/26 PF80A TF80A TF90A OD A C S S S S S S S S C S S S S S S S S S S S S S C C C C C C C C C C C 44 52 62 83 80 98 105 120 120 44 52 52 52 62 83 80 98 105 120 81 99 106 121 55 55 80 55 55 80 55 55 80 80 90 52 52 61 81 76 96 103 117 116 52 52 52 52 62 81 76 96 103 117 77 97 104 118 54 80 79 54 80 79 69 80 79 100 100 15 15 15 15 23 23 23 23 38 15 15 15 15 15 15 23 23 23 23 22 22 22 22 22 26 25 22 26 25 22 26 25 28 28 16 40 32 25 25 25 25 25 25 16 25 60 80 25 25 25 25 25 25 25 25 25 25 3 3 3 3 3 3 3 3 3 3 3 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 dep. on liquid dep. on liquid dep. on liquid dep. on liquid 60 60 60 80 80 80 100 100 100 dep. on liquid dep. on liquid 42 37 52 88 114 215 240 268 332 37 34 41 51 44 60 112 178 166 227 128 245 278 310 70 110 165 51 80 124 92 143 196 250 285 60 57 102 254 198 423 529 811 726 60 57 57 57 102 254 198 423 529 811 210 427 517 794 103 141 339 103 141 339 132 148 339 441 575 818 769 597 408 679 597 533 389 537 720 707 852 1060 505 278 665 595 369 329 718 675 633 459 798 919 537 582 669 431 821 1140 681 667 584 1390 1307 1015 693 1155 1016 907 661 914 1224 1201 1448 1802 859 473 1130 841 627 560 1220 1148 1076 781 1357 1563 974 989 1137 723 1396 1938 1157 1134 992 KSR Magnetostrictive Level Transmitters Limitation of guide tube length for KSR Magnetostrictive Level Transmitters FFG-...-Ex Option A Option B L L 1012-1 Mounted on top of tank Mounted on top of tank and fixed at bottom of tank max. guide tube length in mm Guide tube OD 12 x 1 660 3500 OD 16 x 1 1270 6000 OD 17.2 x 1.6 2100 6000 3000 6000 OD 18 x 1.5 Option A Option B 13 Quality 1012-1 14 1012-1 15 KSR KUEBLER Niveau-Messtechnik AG 69439 Zwingenberg Germany Tel ++49 (0) 62 63 - 87- 0 Fax ++49 (0) 62 63 - 87 99 03/08 1.000 WRB Printed in Germany Subject to technical alterations info@ksr-kuebler.com www.ksr-kuebler.com
Similar documents
KSR Magnetic Float Switches
Level Control Products of America Inc. Charlotte, NC 28273 KSR KUEBLER (SINGAPORE) Level Measurement & Control Pte. Ltd. Singapore 608609 SHANGHAI KSR KUEBLER Automation Instruments Co. Ltd. Shangh...
More information