Flexim: Ultrasonic clamp-on liquid and gas flow meters as well as
Transcription
Flexim: Ultrasonic clamp-on liquid and gas flow meters as well as
Technical Specification FLUXUS® F70x Liquid Ultrasonic Flowmeter for Permanent Installation Designed for wall mounting or installation in 19'' rack systems Features • Precise bi-directional and highly dynamic flow measurement with the non-intrusive clamp-on technology • High precision at fast and slow flow rates, high temperature and zero point stability • Automatic loading of calibration data and transducer detection for a fast and easy set-up (less than 5 min), providing precise and long-term stable results • User-friendly design • Transducers available for a wide range of inner pipe diameters ( 6...6500 mm) and fluid temperatures ( -40...+400 °C) • ATEX, IECEx, FM Class 1 Div. 2 approved transducers for hazardous areas available • HybridTrek automatically switches between transit time and NoiseTrek mode of measurement when high particulate flows are encountered FLUXUS F704, F705 Applications • • • • • • • Chemical industry Petrochemical industry Oil and gas industry Pharmaceutical industry Semiconductor industry Mechanical engineering Water and wastewater industry FLUXUS F709 Measurement with transducers mounted by Variofix L TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 1 FLUXUS® F70x Technical Specification Table of Contents Function ........................................................................................................................................................... 3 Measurement Principle ..................................................................................................................................... 3 Calculation of Volumetric Flow Rate ................................................................................................................. 3 Number of Sound Paths.................................................................................................................................... 4 Typical Measurement Setup ............................................................................................................................. 5 Flow Transmitter ............................................................................................................................................. 6 Technical Data .................................................................................................................................................. 6 Dimensions ....................................................................................................................................................... 9 2 " Pipe Mounting Kit (optional)....................................................................................................................... 11 Terminal Assignment ...................................................................................................................................... 12 Transducers................................................................................................................................................... 14 Transducer Selection ...................................................................................................................................... 14 Transducer Order Code .................................................................................................................................. 15 Technical Data ................................................................................................................................................ 16 Transducer Mounting Fixture ...................................................................................................................... 29 Coupling Materials for Transducers............................................................................................................ 31 Connection Systems..................................................................................................................................... 32 Transducer Cable............................................................................................................................................ 33 Junction Box ................................................................................................................................................. 34 Technical Data ................................................................................................................................................ 34 Dimensions ..................................................................................................................................................... 34 2 " Pipe Mounting Kit (optional)....................................................................................................................... 35 Terminal Assignment ...................................................................................................................................... 35 Clamp-on Temperature Probe (optional) .................................................................................................... 37 2 TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x Function Measurement Principle Transit Time Difference Principle In order to measure the flow of a medium in a pipe, ultrasonic signals are used, employing the transit time difference principle. Ultrasonic signals are emitted by a transducer installed on the pipe and received by a second transducer. These signals are emitted alternately in the flow direction and against it. As the medium in which the signals propagate is flowing, the transit time of the ultrasonic signals in the flow direction is shorter than against the flow direction. The transit time difference, ∆t, is measured and allows the flowmeter to determine the average flow velocity along the propagation path of the ultrasonic signals. A flow profile correction is then performed in order to obtain the area averaged flow velocity, which is proportional to the volumetric flow rate. Two integrated microprocessors control the entire measuring process. This allows the flowmeter to remove disturbance signals, and to check each received ultrasonic wave for its validity which reduces noise. HybridTrek If the gaseous or solid content in the medium increases occasionally during measurement, a measurement with the transit time difference principle is no longer possible. NoiseTrek mode will then be selected by the flowmeter. This measurement method allows the flowmeter to achieve a stable measurement even with high gaseous or solid content. The transmitter can switch automatically between transit time and NoiseTrek mode without any changes to the measurement setup. t Path of the ultrasonic signal 0 t 1 t 2 Transit time difference ∆t Calculation of Volumetric Flow Rate · V = kRe . A . ka . ∆t/(2 . tfl) where · V kRe A ka ∆t tfl - volumetric flow rate fluid mechanics calibration factor cross-sectional pipe area acoustical calibration factor transit time difference transit time in the medium TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 3 FLUXUS® F70x Technical Specification Number of Sound Paths The number of sound paths is the number of transits of the ultrasonic signal through the medium in the pipe. Depending on the number of sound paths, the following methods of installation exist: • reflection arrangement The number of sound paths is even. Both of the transducers are mounted on the same side of the pipe. Correct positioning of the transducers is easier. • diagonal arrangement The number of sound paths is odd. Both of the transducers are mounted on opposite sides of the pipe. In the case of a high signal attenuation by the medium, pipe and coatings, diagonal arrangement with 1 sound path will be used. The preferred method of installation depends on the application. While increasing the number of sound paths increases the accuracy of the measurement, signal attenuation increases as well. The optimum number of sound paths for the parameters of the application will be determined automatically by the transmitter. As the transducers can be mounted with the transducer mounting fixture in reflection arrangement or diagonal arrangement, the number of sound paths can be adjusted optimally for the application. . a a - transducer distance Reflection arrangement, number of sound paths: 2 a Diagonal arrangement, number of sound paths: 3 a>0 Diagonal arrangement, number of sound paths: 1 4 a<0 Diagonal arrangement, number of sound paths: 1, negative transducer distance TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x Typical Measurement Setup RS485 (optional) power supply RS232 transducers U L T R A S O N IC F L O W M E T E R transmitter outputs inputs Example of a measurement setup in reflection arrangement supply line return line volumetric flow rate transducers temperature probe supply temperature U L T R A S O N IC temperature probe return temperature F L O W M E T E R transmitter Example of a heat flow measurement TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 5 FLUXUS® F70x Technical Specification Flow Transmitter Technical Data FLUXUS F704**-NN F704**-A2 standard field device design measurement measurement principle temperature compensation accuracy1 with standard calibration with advanced calibration (optional) with field calibration2 flow transmitter power supply 19 " module ±1.6 % of reading ±0.01 m/s ±1.2 % of reading ±0.01 m/s ±0.5 % of reading ±0.01 m/s 100...230 V/50...60 Hz or 20...32 V DC < 15 W 1, optional: 2 power consumption number of flow measuring channels signal attenuation measuring cycle (1 channel) response time housing material degree of protection according to IEC/EN 60529 dimensions aluminum, powder coated IP65 0...100 s, adjustable 100...1000 Hz 1 s (1 channel), option: 70 ms stainless steel 316L (1.4404) IP66 aluminum IP20 see dimensional drawing weight fixation ambient temperature 42HP x 3U (without back panel) 2.8 kg 4.76 kg wall mounting, optional: 2 " pipe mounting -40...+60 °C (-40...-20 °C without operation of the display) 2 x 16 characters, dot matrix, backlight English, German, French, Dutch, Spanish F704**-A2 2 II3G II2D Ex nA nC ic IIC T4 Gc Ta -40...+60 °C Ex tb IIIC T 120 °C Db Ta -40...+50 °C IBExU11ATEX1015 IECEx IBE 11.0008 gas: non sparking dust: protection by enclosure Um = 250 V (power supply 100...230 V AC) Um = 36 V (power supply 20...32 V DC) 0637 F705**-A2 2 see dimensional drawing 1.7 kg 19 " rack mounting -20...+60 °C - II3G Ex nA nC ic IIC T4 Gc II3D Ex tc IIIC T 100 °C Dc Ta -20...+60 °C gas: non sparking dust: protection by enclosure Um = 250 V (power supply 100...230 V AC) Um = 36 V (power supply 20...32 V DC) 1 for transit time difference principle, reference conditions and v > 0.15 m/s 2 reference uncertainty < 0.2 % 6 F709**-NN transit time difference correlation principle, automatic NoiseTrek selection for measurements with high gaseous or solid content 0.01...25 m/s 0.15 % of reading ±0.01 m/s all acoustically conductive liquids with < 10 % gaseous or solid content in volume (transit time difference principle) corresponding to the recommendations in ANSI/ASME MFC-5.1-2011 flow velocity repeatability medium display menu language explosion protection transmitter zone marking A T E X / I certification ATEX E certification IECEx C type of protection E x intrinsic safety parameters F705**-NN F705**-A2 field device with stainless steel housing - TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x FLUXUS F704**-NN F704**-A2 measuring functions physical quantities F705**-NN F705**-A2 F709**-NN volumetric flow rate, mass flow rate, flow velocity, heat flow (if temperature inputs are installed) volume, mass, optional: heat quantity average, difference, sum (2 measuring channels necessary) sound speed, signal amplitude, SNR, SCNR, standard deviation of amplitudes and transit times totalizer calculation functions diagnostic functions data logger loggable values all physical quantities, totalized values and diagnostic values capacity > 100 000 measured values SD card, removable (optional) loggable values all physical quantities and totalized values capacity min. 2 GB communication interface - process integration (optional): RS485 (emitter) or Modbus RTU or - process integration (optional): HART or BACnet MS/TP or SD card RS485 (emitter) or Modbus RTU or HART or BACnet MS/TP - diagnosis: RS2323 - diagnosis: RS232 serial data kit (optional) software (all Windows™ versions) -FluxData: download of measurement data, graphical presentation, conversion to other formats (e.g. for Excel™) -FluxDiag (optional): online diagnostics and report generation -FluxKoef: creating medium data sets -FluxSubstanceLoader: upload of medium data sets RS2323 RS232 - USB3 сable adapter outputs (optional) number - range accuracy active output passive output The outputs are galvanically isolated from the transmitter. on request switchable current output (nonEx) All switchable current outputs are switched to active or passive mode at the same time. 4...20 mA (3.2...22 mA) 0.04 % of reading ±3 μA Rext < 350 Ω Uext = 8...30 V, depending on Rext, Rext < 1 kΩ current output current output - range - accuracy - active output - passive output current output I1 in HART mode - range - passive output range accuracy internal resistance range open collector Reed relay open collector optorelay binary output as alarm output - functions binary output as pulse output - pulse value - pulse width 3 RS232 RS232 - USB 0/4...20 mA 0.1 % of reading ±15 μA Rext < 500 Ω Uext = 4...24 V, depending on Rext, Rext < 1 kΩ 4...20 mA Uext = 10...24 V voltage output 0...1 V or 0...10 V 0...1 V: 0.1 % of reading ±1 mV 0...10 V: 0.1 % of reading ±10 mV Ri = 500 Ω frequency output 0...5 kHz 24 V/4 mA, Ri = 66.5 Ω binary output 48 V/100 mA, P1...P4: Ri = 22 Ω 48 V/100 mA, P1...P4: Ri = 22 Ω 24 V/4 mA, P1...P4: Ri = 22 Ω 24 V/4 mA, P1...P4: Ri = 22 Ω 26 V/100 mA limit, change of flow direction or error limit, change of flow direction or error 0.01...1000 units optorelay: 1...1000 ms Reed relay, open collector: 80...1000 ms 0.01...1000 units 80...1000 ms F70x**-A2: connection of the interface RS232 outside of explosive atmosphere (housing cover open) TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 7 FLUXUS® F70x FLUXUS Technical Specification F704**-NN F704**-A2 F705**-NN F705**-A2 F709**-NN inputs (optional) number type connection range resolution accuracy accuracy active input - range passive input - range range accuracy internal resistance switching signal functions 8 The inputs are galvanically isolated from the transmitter. max. 4, on request temperature input Pt100/Pt1000 4-wire -150...+560 °C 0.01 K ±0.01 % of reading ±0.03 K current input 0.1 % of reading ±10 μA Ui = 24 V, Ri = 50 Ω, Pi < 0.5 W, not short-circuit proof 0...20 mA Ri = 50 Ω, Pi < 0.3 W -20...+20 mA 0.1 % of reading ±10 μA Ui = 15 V, Ri = 50 Ω, Pi < 0.5 W, not short-circuit proof 0...20 mA Ri = 50 Ω, Pi < 0.3 W -20...+20 mA voltage input 0...1 V 0.1 % of reading ±1 mV Ri = 1 MΩ binary input 5...30 V, 1 mA -resetting the measured values -resetting the totalizers -stopping the totalizers -activation of the measuring mode for highly dynamic flows TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x Dimensions 10 70* FLUXUS F704 * F704**-A2: +10 mm above the display Ø 4.5 287 265 163 200 fixing holes for wall mounting thread: 6x M20 x 1.5 cable gland: max. 6x M20 98 87 FLUXUS F705 255 163 370 320 cable gland: max. 6x M20 with flat gasket and counter nut TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 9 FLUXUS® F70x Technical Specification FLUXUS F709 198 15 208 170 222 44 123 129 M2.5 213 110 129 in mm 10 TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x 2 " Pipe Mounting Kit (optional) FLUXUS F704 FLUXUS F705 TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 11 FLUXUS® F70x Technical Specification Terminal Assignment FLUXUS F704, F705 K L 1 K L 2 K L 4 K L 3 X _ A V A V X _ A R A V S A G N A R S A R B V B V S B G N B R S B R S A 1 S A 2 S A 3 S A 4 S B 1 S B 2 S B 3 S B 4 X 1 X 2 X _ B V X _ B R T 1 A T 1 a T 1 B T 1 b S 1 S 2 T 2 A T 2 a T 2 B T 2 b T 3 A T 3 B T 3 a T 3 b S 3 S 4 T 4 A T 4 B A + T 4 a T 4 b 1 0 1 B - 1 0 3 P 1 + P 2 + P 1 - P 2 - P 3 + P 3 - P 4 + P 5 a P 4 - P 5 b P 6 a P 6 b P 7 a P 7 b P E N (-) L (+ ) equipotential bonding terminal (FLUXUS F704**-A2) equipotential bonding terminal (FLUXUS F705) power supply terminal strip KL3 terminal PE N(-) L(+) connection (AC) connection (DC) earth earth neutral phase + transducers terminal strip KL1 extension cable (transducers *****8*, ****LI*, *****52) transducer cable (transducers *****8*, ****LI*) measuring channel A measuring channel B terminal terminal connection extension cable connection system AS (transducers *****Z7, *****C3) transducer cable (transducers *****52) measuring channel A measuring channel B connection terminal connection AV signal BV signal X_AV X_BV SMB connector AVS shield BVS shield X_AR X_BR SMB connector ARS shield BRS shield X1 X2 AMP-Quick connector1 AR signal BR signal 1 connection system AS outputs2 terminal strip KL4 terminal P1+...P4+, P1-...P4P5a...P7a, P5b...P7b RS485, Modbus, BACnet (optional) connection current output, voltage output, frequency output or binary output (Reed relay, open collector) binary output terminal strip KL4 terminal A+ B101 connection signal + signal shield analog inputs2 terminal strip KL2 terminal T1a...T4a T1A...T4A T1b...T4b T1B...T4B S1...S4 temperature probe direct connection connection with extension cable red red red/blue gray white/blue blue white white shield shield passive current source connection of an active input not connected + not connected not connected active current source connection of a passive input not connected + not connected not connected binary inputs2 terminal strip KL4 terminal P1+...P2+, P1-...P22 The number, type and terminal assignment of the outputs and inputs will be customized. 12 TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x FLUXUS F709 A K L 1 P 7 a P 6 a P 5 a P 7 + P 6 + P 5 + P 4 + P 3 + P 2 + P 1 + K L 3 T 4 B P 7 b T 4 A P 6 b S 3 P 5 b T 3 B P 7 - T 3 A P 6 - T 2 B P 5 - T 2 A P 4 - S 1 P 3 - T 1 B P 2 - T 1 A P 1 - K L 2 K L 5 T 4 b T 4 a S 4 T 3 b T 3 a X 5 T 2 b L - 4 B 4 A + L 1 4 3 N 4 2 P E B K L 7 S A 1 S B 1 S A 2 S B 2 S A 3 S B 3 S A 4 S B 4 X 6 A V X 8 B V X 7 T 2 a S 2 T 1 b T 1 a K L 6 K L 4 L + C H A N N E L A V B V A V S B V S A G N B G N A R S B R S A R B R X 6 A R X 8 B R K L 8 4 1 power supply terminal strip KL2 terminal PE N L1 connection (AC) terminal earth PE neutral Lphase L+ connection (DC) earth + transducers terminal strip KL6, KL8 extension cable (transducers *****8*, ****LI*, *****52) transducer cable (transducers ****LI*) measuring channel A measuring channel B terminal connection terminal extension cable connection system AS (transducers *****Z7, *****C3) measuring channel A measuring channel B connection terminal connection AV signal BV signal X_AV X_BV SMB connector AVS ARS AR shield shield signal BVS BRS BR shield shield signal X_AR X1 X_BR X2 SMB connector AMP-Quick connector outputs1 RS485, Modbus, BACnet (optional) terminal strip KL1 terminal P1+...P4+, P1-...P4- connection current output, voltage output, frequency output or binary output P5+...P7+, P5-...P7P5a...P7a, P5b...P7b binary output (open collector) binary output (Reed relay) terminal strip KL4 terminal 4A+ 4B43 connection signal + signal shield analog inputs1 terminal strip KL3 terminal T1a...T4a T1A...T4A T1b...T4b T1B...T4B S1...S4 temperature probe direct connection connection with extension cable red red red/blue gray white/blue blue white white shield shield passive current source connection of an active input not connected + not connected not connected active current source connection of a passive input not connected + not connected not connected binary inputs1 terminal strip KL1 terminal P1+...P2+, P1-...P21 The number, type and terminal assignment of the outputs and inputs will be customized. TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 13 FLUXUS® F70x Technical Specification Transducers Transducer Selection transducer order code FSG 400 FSK 100 FSM 50 FSP 25 FSQ 10 FSS 6 5 recommended 14 50 3600 2000 200 150 10 6500 200 100 25 10 500 6500 3400 600 400 70 50 100 500 1000 5000 inner pipe diameter [mm] possible TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x Transducer Order Code 1, 2 3 4 5, 6 7, 8 9...11 12, 13 no. of character / option - extension cable connection system explosion protection - ambient temperature transducer frequency transducer description FS set of ultrasonic flow transducers for liquids measurement, shear wave G 0.2 MHz K 0.5 MHz M 1 MHz P 2 MHz Q 4 MHz S 8 MHz N normal temperature range E extended temperature range (shear wave transducers with transducer frequency M, P, Q) A1 ATEX zone 1/IECEx zone 1 A2 ATEX zone 2 F2 FM Class I Div. 2 NN not explosion proof AS with Amphenol connector (not explosion proof transducers) TS direct connection or connection via junction box XXX cable length in m, for max. length of extension cable see page 32 connection system TS: 0 m: without junction box > 0 m: with junction box JB01 (zone 1), JB02 (ATEX zone 2, FM), JB03 (not explosion proof), JBP2 (transducers IP68, ATEX zone 2), JBP3 (transducers IP68, not explosion proof) LC long transducer cable (only FSG, FSK) IP68 degree of protection IP68 with connection system TS OS housing with stainless steel 316 (with connection system TS) example FS M - N A1 TS - TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 - - 030 shear wave transducer 1 MHz, normal temperature range, ATEX zone 1/IECEx zone 1, connection system TS with junction box JB01 and extension cable 30 m / 15 FLUXUS® F70x Technical Specification Technical Data Shear Wave Transducers (zone 1) transducer frequency inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDK1N81 FSK-NA1TS FSK-NA1TS/OS 0.5 mm mm mm mm 400 500 6500 6500 100 200 3600 6500 mm mm - - PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PEEK IP65 PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PEEK IP65 m 1699 5 1699 5 mm mm mm 129.5 51 67 126.5 51 67.5 h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing CDG1N81 FSG-NA1TS FSG-NA1TS/OS MHz 0.2 h technical type order code l b b l ambient temperature min. °C -40 max. °C +130 temperature x compensation explosion protection category gas: 2G dust: 2D zone 1 21 explosion protection temperature (pipe surface) min. °C -55 °C +180 A max. T marking II2G 0637 E II2D Ex e q IIC T6...T3 Gb X / Ex tb IIIC TX Db I certification ATEX IBExU07ATEX1168 X E certification IECEx IECEx IBE 08.0007X C type of protection gas: increased safety, E powder filling x dust: protection by enclosure transducer x mounting fixture necessary remark on request 16 -40 +130 x gas: 2G 1 dust: 2D 21 -55 +180 II2G II2D Ex e q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure x 0637 TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification mm mm mm mm 50 100 2000 3400 25 50 200 600 10 25 150 400 mm mm - - - PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PEEK IP65 PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PEEK IP65 PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PEEK IP65 m 1699 4 1699 4 1699 3 mm mm mm 64 32 40.5 64 32 40.5 40 22 25.5 h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing CDQ2N81 FSQ-NA1TS FSQ-NA1TS/OS 4 ambient temperature min. °C -40 max. °C +130 temperature x compensation explosion protection category gas: 2G dust: 2D zone 1 21 explosion protection temperature (pipe surface) min. °C -55 °C +180 A max. T marking II2G 0637 E II2D Ex e q IIC T6...T3 Gb X / Ex tb IIIC TX Db I certification ATEX IBExU07ATEX1168 X E certification IECEx IECEx IBE 08.0007X C type of protection gas: increased safety, E powder filling x dust: protection by enclosure transducer x mounting fixture necessary TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 l b l b l h inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDP2N81 FSP-NA1TS FSP-NA1TS/OS 2 -40 +130 x gas: 2G 1 b transducer frequency CDM2N81 FSM-NA1TS FSM-NA1TS/OS MHz 1 h technical type order code FLUXUS® F70x -40 +130 x dust: 2D 21 gas: 2G 1 dust: 2D 21 -55 +180 -55 +180 II2G II2D Ex e q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure x II2G II2D Ex e q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure x 0637 0637 17 FLUXUS® F70x Technical Specification Shear Wave Transducers (zone 1, IP68) CDM2LI1 FSM-NA1TS/IP68 1 CDP2LI1 FSP-NA1TS/IP68 2 mm mm mm mm 400 500 6500 6500 100 200 3600 6500 50 100 2000 3400 25 50 200 600 mm mm - - - - PEEK with stainless steel cap 316Ti (1.4571) PEEK IP68 1 PEEK with stainless steel cap 316Ti (1.4571) PEEK IP68 1 PEEK with stainless steel cap 316Ti (1.4571) PEEK IP68 1 PEEK with stainless steel cap 316Ti (1.4571) PEEK IP68 1 m 2550 12 2550 12 2550 12 2550 12 mm mm mm 130 54 83.5 130 54 83.5 72 32 46 72 32 46 h h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing CDK1LI1 FSK-NA1TS/IP68 0.5 l l l ambient temperature min. °C -40 max. °C +100 temperature x compensation explosion protection category gas: 2G dust: 2D zone 1 21 explosion protection temperature (pipe surface) min. °C -55 A max. °C +180 T marking II2G 0637 E II2D X Ex q IIC T6...T3 Gb / Ex tb IIIC TX Db I certification ATEX IBExU07ATEX1168 X E IECEx IBE 08.0007X C certification IECEx gas: powder filling E type of protection dust: protection by x enclosure transducer x mounting fixture necessary remark on request 1 18 -40 +100 x gas: 2G 1 -40 +100 x dust: 2D 21 gas: 2G 1 b b b b l h inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDG1LI1 FSG-NA1TS/IP68 MHz 0.2 h technical type order code transducer frequency -40 +100 x dust: 2D 21 gas: 2G 1 dust: 2D 21 -55 +180 -55 +180 -55 +180 II2G II2D Ex q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: powder filling dust: protection by enclosure x II2G II2D Ex q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: powder filling dust: protection by enclosure x II2G II2D Ex q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: powder filling dust: protection by enclosure x 0637 0637 0637 test conditions: 3 months/2 bar (20 m)/20 °C TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x Shear Wave Transducers (zone 1, extended temperature range) mm mm mm mm 50 100 2000 3400 25 50 200 600 10 25 150 400 mm mm - - - PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PI IP56 PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PI IP56 PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PI IP56 m 6111 4 6111 4 6111 3 mm mm mm 64 32 40.5 64 32 40.5 40 22 25.5 h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing CDQ2E85 FSQ-EA1TS FSQ-EA1TS/OS 4 ambient temperature min. °C -30 max. °C +200 temperature x compensation explosion protection category gas: 2G dust: 3D zone 1 22 explosion protection temperature (pipe surface) min. °C -45 °C +225 A max. T marking II2G 0637 E II2D Ex e q IIC T6...T2 Gb X / Ex tb IIIA TX Db I certification ATEX IBExU07ATEX1168 X E certification IECEx IECEx IBE 08.0007X C type of protection gas: increased safety, E powder filling x dust: protection by enclosure transducer x mounting fixture necessary TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 l b l b l h inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDP2E85 FSP-EA1TS FSP-EA1TS/OS 2 -30 +200 x gas: 2G 1 b transducer frequency CDM2E85 FSM-EA1TS FSM-EA1TS/OS MHz 1 h technical type order code -30 +200 x dust: 3D 22 gas: 2G 1 dust: 3D 22 -45 +225 -45 +225 II2G II2D Ex e q IIC T6...T2 Gb Ex tb IIIA TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure x II2G II2D Ex e q IIC T6...T2 Gb Ex tb IIIA TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure x 0637 0637 19 FLUXUS® F70x Technical Specification Shear Wave Transducers (ATEX zone 2, FM or not explosion proof) CLK1N52 FSK-NA2TS/LC FSK-NA2TS/LC/OS FSK-NF2TS/LC FSK-NF2TS/LC/OS FSK-NNNTS/LC FSK-NNNTS/LC/OS 0.5 mm mm mm mm 400 500 6500 6500 400 500 6500 6500 100 200 3600 6500 100 200 3600 6500 mm mm - - - - PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PEEK IP67 PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PEEK IP67 PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PEEK IP67 PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PEEK IP67 m 1699 5 1699 9 1699 5 1699 9 mm mm mm 129.5 51 67 129.5 51 67 126.5 51 67.5 126.5 51 67.5 ambient temperature min. °C max. °C temperature compensation explosion protection order code -40 +130 x FSG-NA2TS FSG-NA2TS/OS category gas: 3G dust: 3D zone 2 22 explosion protection temperature (pipe surface) min. °C -55 max. °C +190 A marking T II3G Ex nA IIC T6...T3 Gc E Ta -55...+190 °C X II3D Ex tc IIIC TX Dc certification type of protection gas: non sparking dust: protection by enclosure transducer x mounting fixture necessary order code FSG-NF2TS FSG-NF2TS/OS explosion protection temperature min. °C -40 F max. °C +125 M marking NI/Cl. I,II,III/Div. 2 / GP A,B,C,D,E,F,G/ Temp. Codes dwg 3860 type of protection non incendive remark on request 20 h l b l l b b l h CDK1N52 FSK-NA2TS FSK-NA2TS/OS FSK-NF2TS FSK-NF2TS/OS FSK-NNNTS FSK-NNNTS/OS 0.5 h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing CLG1N52 FSG-NA2TS/LC FSG-NA2TS/LC/OS FSG-NF2TS/LC FSG-NF2TS/LC/OS FSG-NNNTS/LC FSG-NNNTS/LC/OS 0.2 b transducer frequency inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDG1N52 FSG-NA2TS FSG-NA2TS/OS FSG-NF2TS FSG-NF2TS/OS FSG-NNNTS FSG-NNNTS/OS MHz 0.2 h technical type order code -40 +130 x -40 +130 x -40 +130 x FSG-NA2TS/LC FSG-NA2TS/LC/OS gas: 3G dust: 3D 2 22 FSK-NA2TS FSK-NA2TS/OS gas: 3G dust: 3D 2 22 FSK-NA2TS/LC FSK-NA2TS/LC/OS gas: 3G dust: 3D 2 22 -55 +190 -55 +190 -55 +190 II3G Ex nA IIC T6...T3 Gc Ta -55...+190 °C II3D Ex tc IIIC TX Dc gas: non sparking dust: protection by enclosure x II3G Ex nA IIC T6...T3 Gc Ta -55...+190 °C II3D Ex tc IIIC TX Dc gas: non sparking dust: protection by enclosure x II3G Ex nA IIC T6...T3 Gc Ta -55...+190 °C II3D Ex tc IIIC TX Dc gas: non sparking dust: protection by enclosure x FSG-NF2TS/LC FSG-NF2TS/LC/OS FSK-NF2TS FSK-NF2TS/OS FSK-NF2TS/LC FSK-NF2TS/LC/OS -40 +125 -40 +125 -40 +125 NI/Cl. I,II,III/Div. 2 / NI/Cl. I,II,III/Div. 2 / NI/Cl. I,II,III/Div. 2 / GP A,B,C,D,E,F,G/ GP A,B,C,D,E,F,G/ GP A,B,C,D,E,F,G/ Temp. Codes dwg 3860 Temp. Codes dwg 3860 Temp. Codes dwg 3860 non incendive non incendive non incendive on request TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification technical type order code transducer frequency inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDS1N52 FSS-NF2TS FSS-NNNTS MHz 8 mm mm mm mm 6 10 70 70 mm mm stainless steel 304 (1.4301) PEI IP65 m 1699 2 mm mm mm 25 13 17 h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing FLUXUS® F70x b l ambient temperature min. °C -30 max. °C +130 temperature x compensation explosion protection order code FSS-NF2TS explosion protection temperature min. °C -40 F °C +125 M max. marking NI/Cl. I,II,III/Div. 2 / GP A,B,C,D,E,F,G/ Temp. Codes dwg 3860 TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 21 FLUXUS® F70x Technical Specification Shear Wave Transducers (ATEX zone 2, FM or not explosion proof) CDQ2N52 FSQ-NA2TS FSQ-NA2TS/OS FSQ-NF2TS FSQ-NF2TS/OS FSQ-NNNTS FSQ-NNNTS/OS 4 mm mm mm mm 50 100 2000 3400 25 50 200 600 10 25 150 400 mm mm - - - PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PEEK IP67 PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PEEK IP67 PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PEEK IP67 m 1699 4 1699 4 1699 3 mm mm mm 64 32 40.5 64 32 40.5 40 22 25.5 ambient temperature min. °C max. °C temperature compensation explosion protection order code A T E X F M 22 l l -40 +130 x FSM-NA2TS FSM-NA2TS/OS category gas: 3G dust: 3D zone 2 22 explosion protection temperature (pipe surface) min. °C -55 max. °C +190 marking II3G Ex nA IIC T6...T3 Gc Ta -55...+190 °C II3D Ex tc IIIC TX Dc certification type of protection gas: non sparking dust: protection by enclosure transducer x mounting fixture necessary order code FSM-NF2TS FSM-NF2TS/OS explosion protection temperature min. °C -55 max. °C +190 marking NI/Cl. I,II,III/Div. 2 / GP A,B,C,D,E,F,G/ Temp. Codes dwg 3860 type of protection non incendive b b l h h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing CDP2N52 FSP-NA2TS FSP-NA2TS/OS FSP-NF2TS FSP-NF2TS/OS FSP-NNNTS FSP-NNNTS/OS 2 b transducer frequency inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDM2N52 FSM-NA2TS FSM-NA2TS/OS FSM-NF2TS FSM-NF2TS/OS FSM-NNNTS FSM-NNNTS/OS MHz 1 h technical type order code -40 +130 x -40 +130 x FSP-NA2TS FSP-NA2TS/OS gas: 3G dust: 3D 2 22 FSQ-NA2TS FSQ-NA2TS/OS gas: 3G dust: 3D 2 22 -55 +190 -55 +190 II3G Ex nA IIC T6...T3 Gc Ta -55...+190 °C II3D Ex tc IIIC TX Dc gas: non sparking dust: protection by enclosure x II3G Ex nA IIC T6...T3 Gc Ta -55...+190 °C II3D Ex tc IIIC TX Dc gas: non sparking dust: protection by enclosure x FSP-NF2TS FSP-NF2TS/OS FSQ-NF2TS FSQ-NF2TS/OS -55 +190 -55 +190 NI/Cl. I,II,III/Div. 2 / NI/Cl. I,II,III/Div. 2 / GP A,B,C,D,E,F,G/ GP A,B,C,D,E,F,G/ Temp. Codes dwg 3860 Temp. Codes dwg 3860 non incendive non incendive TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x Shear Wave Transducers (ATEX zone 2 or not explosion proof, IP68) inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDM2LI8 FSM-NA2TS/IP68 FSM-NNNTS/IP68 1 CDP2LI8 FSP-NA2TS/IP68 FSP-NNNTS/IP68 2 mm mm mm mm 400 500 6500 6500 100 200 3600 6500 50 100 2000 3400 25 50 200 600 mm mm - - - - PEEK with stainless steel cap 316Ti (1.4571) PEEK IP68 1 PEEK with stainless steel cap 316Ti (1.4571) PEEK IP68 1 PEEK with stainless steel cap 316Ti (1.4571) PEEK IP68 1 PEEK with stainless steel cap 316Ti (1.4571) PEEK IP68 1 m 2550 12 2550 12 2550 12 2550 12 mm mm mm 130 54 83.5 130 54 83.5 72 32 46 72 32 46 h h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing CDK1LI8 FSK-NA2TS/IP68 FSK-NNNTS/IP68 0.5 l l ambient temperature min. °C -40 max. °C +100 temperature x compensation explosion protection order code FSG-NA2TS/IP68 category gas: 3G dust: 3D zone 2 22 explosion protection temperature (pipe surface) min. °C -40 max. °C +90 marking A II3G Ex nA IIC T6...T5 Gc T Ta -40...+90 °C E II3D Ex tc IIIC TX Dc X certification type of protection gas: non sparking dust: protection by enclosure transducer x mounting fixture necessary remark on request 1 b b b l b l h transducer frequency CDG1LI8 FSG-NA2TS/IP68 FSG-NNNTS/IP68 MHz 0.2 h technical type order code -40 +100 x -40 +100 x -40 +100 x FSK-NA2TS/IP68 gas: 3G dust: 3D 2 22 FSM-NA2TS/IP68 gas: 3G dust: 3D 2 22 FSP-NA2TS/IP68 gas: 3G dust: 3D 2 22 -40 +90 -40 +90 -40 +90 II3G Ex nA IIC T6...T5 Gc Ta -40...+90 °C II3D Ex tc IIIC TX Dc gas: non sparking dust: protection by enclosure x II3G Ex nA IIC T6...T5 Gc Ta -40...+90 °C II3D Ex tc IIIC TX Dc gas: non sparking dust: protection by enclosure x II3G Ex nA IIC T6...T5 Gc Ta -40...+90 °C II3D Ex tc IIIC TX Dc gas: non sparking dust: protection by enclosure x test conditions: 3 months/2 bar (20 m)/20 °C TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 23 FLUXUS® F70x Technical Specification Shear Wave Transducers (connection system AS, not explosion proof) mm mm mm mm 400 500 6500 6500 400 500 6500 6500 100 200 3600 6500 100 200 3600 6500 mm mm - - - - PEEK with stainless steel cap 304 (1.4301) PEEK IP67 PEEK with stainless steel cap 304 (1.4301) PEEK IP67 PEEK with stainless steel cap 304 (1.4301) PEEK IP67 PEEK with stainless steel cap 304 (1.4301) PEEK IP67 m 1699 5 1699 9 1699 5 1699 9 mm mm mm 129.5 51 67 129.5 51 67 126.5 51 67.5 126.5 51 67.5 ambient temperature min. °C max. °C temperature compensation remark 24 b -40 +130 x -40 +130 x on request on request l -40 +130 x b l l b l h CLK1NZ7 FSK-NNNAS/LC 0.5 h CDK1NZ7 FSK-NNNAS 0.5 h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing CLG1NZ7 FSG-NNNAS/LC 0.2 b inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDG1NZ7 FSG-NNNAS MHz 0.2 h technical type order code transducer frequency -40 +130 x TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification technical type order code transducer frequency inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDS1NZ7 FSS-NNNAS MHz 8 mm mm mm mm 6 10 70 70 mm mm stainless steel 304 (1.4301) PEI IP65 m 1699 2 mm mm mm 25 13 17 h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing FLUXUS® F70x b l ambient temperature min. °C max. °C temperature compensation -30 +130 x TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 25 FLUXUS® F70x Technical Specification Shear Wave Transducers (connection system AS, not explosion proof) CDQ2NZ7 FSQ-NNNAS 4 mm mm mm mm 50 100 2000 3400 25 50 200 600 10 25 150 400 mm mm - - - PEEK with stainless steel cap 304 (1.4301) PEEK IP67 PEEK with stainless steel cap 304 (1.4301) PEEK IP67 PEEK with stainless steel cap 304 (1.4301) PEEK IP67 m 1699 4 1699 4 1699 3 mm mm mm 64 32 40.5 64 32 40.5 40 22 25.5 ambient temperature min. °C max. °C temperature compensation 26 -40 +130 x l b l b l h h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing CDP2NZ7 FSP-NNNAS 2 -40 +130 x b inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDM2NZ7 FSM-NNNAS MHz 1 h technical type order code transducer frequency -40 +130 x TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x Shear Wave Transducers (extended temperature range, ATEX zone 2, FM or not explosion proof) CDQ2E52 FSQ-EA2TS FSQ-EA2TS/OS FSQ-EF2TS FSQ-EF2TS/OS FSQ-ENNTS FSQ-ENNTS/OS 4 mm mm mm mm 50 100 2000 3400 25 50 200 600 10 25 150 400 mm mm - - - PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PI IP56 PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PI IP56 PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PI IP56 m 6111 4 6111 4 6111 3 mm mm mm 64 32 40.5 64 32 40.5 40 22 25.5 h h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing CDP2E52 FSP-EA2TS FSP-EA2TS/OS FSP-EF2TS FSP-EF2TS/OS FSP-ENNTS FSP-ENNTS/OS 2 l A T E X F M -30 +200 x FSM-EA2TS FSM-EA2TS/OS category gas: 3G dust: 3D zone 2 22 explosion protection temperature (pipe surface) min. °C -45 max. °C +235 marking II3G Ex nA IIC T6...T2 Gc Ta -45...+235 °C II3D Ex tc IIIB TX Dc certification type of protection gas: non sparking dust: protection by enclosure transducer x mounting fixture necessary order code FSM-EF2TS FSM-EF2TS/OS explosion protection temperature min. °C -45 max. °C +235 marking NI/Cl. I,II,III/Div. 2 / GP A,B,C,D,E,F,G/ Temp. Codes dwg 3860 type of protection non incendive TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 l l b b ambient temperature min. °C max. °C temperature compensation explosion protection order code h transducer frequency inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDM2E52 FSM-EA2TS FSM-EA2TS/OS FSM-EF2TS FSM-EF2TS/OS FSM-ENNTS FSM-ENNTS/OS MHz 1 b technical type order code -30 +200 x -30 +200 x FSP-EA2TS FSP-EA2TS/OS gas: 3G dust: 3D 2 22 FSQ-EA2TS FSQ-EA2TS/OS gas: 3G dust: 3D 2 22 -45 +235 -45 +235 II3G Ex nA IIC T6...T2 Gc Ta -45...+235 °C II3D Ex tc IIIB TX Dc gas: non sparking dust: protection by enclosure x II3G Ex nA IIC T6...T2 Gc Ta -45...+235 °C II3D Ex tc IIIB TX Dc gas: non sparking dust: protection by enclosure x FSP-EF2TS FSP-EF2TS/OS FSQ-EF2TS FSQ-EF2TS/OS -45 +235 -45 +235 NI/Cl. I,II,III/Div. 2 / NI/Cl. I,II,III/Div. 2 / GP A,B,C,D,E,F,G/ GP A,B,C,D,E,F,G/ Temp. Codes dwg 3860 Temp. Codes dwg 3860 non incendive non incendive 27 FLUXUS® F70x Technical Specification Shear Wave Transducers (extended temperature range, not explosion proof, connection system AS) CDQ2EZ7 FSQ-ENNAS 4 mm mm mm mm 50 100 2000 3400 25 50 200 600 10 25 150 400 mm mm - - - PI with stainless steel cap 304 (1.4301) PI IP65 PI with stainless steel cap 304 (1.4301) PI IP65 PI with stainless steel cap 304 (1.4301) PI IP65 m 6111 4 6111 4 6111 3 mm mm mm 64 32 40.5 64 32 40.5 40 22 25.5 ambient temperature min. °C max. °C temperature compensation 28 -30 +200 x l b l b l h h contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing CDP2EZ7 FSP-ENNAS 2 -30 +200 x b inner pipe diameter d min. extended min. recommended max. recommended max. extended pipe wall thickness min. max. material housing CDM2EZ7 FSM-ENNAS MHz 1 h technical type order code transducer frequency -30 +200 x TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x Transducer Mounting Fixture Order Code 3 4 5 6 7...9 10, 11 no. of character / option outer pipe diameter - fixation size - measurement arrangement description transducer transducer mounting fixture 1, 2 VL Variofix L VС Variofix C WI transducer box for WaveInjector K transducers with transducer frequency G, K M transducers with transducer frequency M, P Q transducers with transducer frequency Q S transducers with transducer frequency S D reflection arrangement or diagonal arrangement R reflection arrangement S small M medium L large S tension straps W welding N without fixation 002 10...20 mm 004 20...40 mm T36 40...360 mm 013 10...130 mm 036 130...360 mm 092 360...920 mm 200 920...2000 mm 450 2000...4500 mm 940 4500...9400 mm NDR any IP68 degree of protection IP68 OS housing with stainless steel 316 Z special design example VL M - D S - TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 S 200 Variofix L and tension straps for transducers with transducer frequency M, P / 29 FLUXUS® F70x Technical Specification Variofix L (VLS) transducers: CDS1N52, CDS1NZ7 material: stainless steel 304 (1.4301), 303 (1.4305) material: stainless steel 304 (1.4301), 301 (1.4310), 410 (1.4006) option OS: 316 (1.4571), 316L (1.4404), 17-7PH (1.4568) Variofix L (VLK, VLM, VLQ) inner length: VLK: 348 mm, option IP68: 368 mm VLM: 234 mm VLQ: 176 mm dimensions: VLK: 423 x 90 x 93 mm, option IP68: 443 x 94 x 105 mm VLM: 309 x 57 x 63 mm VLQ: 247 x 43 x 47 mm material: stainless steel 304 (1.4301), 301 (1.4310) option OS: 316 (1.4571) Variofix C (VC) inner length: VCK-*L: 500 mm VCK-*S: 350 mm VCM: 400 mm VCQ: 250 mm dimensions: VCK-*L: 560 x 122 x 102 mm, option IP68: 560 x 126 x 120 mm VCK-*S: 410 x 122 x 102 mm, option IP68: 410 x 126 x 120 mm VCM: 460 x 96 x 80 mm VCQ: 310 x 85 x 62 mm transducer box WI for WaveInjector transducer box see Technical Specification TSWaveInjectorVx-x 30 TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x Coupling Materials for Transducers < 24 h long time measurement 1 2 normal temperature range (4th character of transducer order code = N) < 100 °C < 170 °C coupling coupling compound compound type E or type N or coupling foil coupling foil type VT type VT coupling foil coupling foil type VT1 type VT2 extended temperature range (4th character of transducer order code = E) < 150 °C < 200 °C coupling coupling compound compound type E or H or type E or coupling foil coupling foil type VT type VT coupling foil coupling foil type VT1 type VT2 WaveInjector WI-400 < 280 °C coupling foil type A and coupling foil type VT 280...400 °C coupling foil type B and coupling foil type VT coupling foil type A and coupling foil type VT coupling foil type B and coupling foil type VT < 5 years < 6 months Technical Data type coupling compound type N coupling compound type E coupling compound type H coupling foil type A coupling foil type B order code 990739-1 ambient temperature material °C -30...+130 mineral grease paste 990739-2 -30...+200 silicone paste 990739-3 -30...+250 fluoropolymer paste 990739-7 max. 280 lead 990739-8 > 280...400 silver -10...+200 fluoroelastomer coupling foil type VT 990739-0 990739-6 990739-14 990739-5 TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 remark for transducers with transducer frequency G, H, K for shear wave transducers with transducer frequency M, P for shear wave transducers IP68 and Lambwave transducers with transducer frequency M, P for transducers with transducer frequency Q 31 FLUXUS® F70x Technical Specification Connection Systems connection system TS connection with extension cable direct connection (only F704, F705) transducers technical type *****8* JB01 x l transmitter transmitter x ****LI* JB01, JBP2, JBP3 x transmitter transmitter x l *****52 JB02, JB03 x l transmitter transmitter x connection system AS connection with extension cable x y transmitter l transducer frequency (3d character of transducer order code) T S cable length m cable length (option LC) m cable length (option IP68) m A S cable length m cable length (option LC) m transducers technical type *****Z7 *****C3 G, H, K x 5 9 12 x 2 2 M, P y 3 7 l ≤ 300 ≤ 300 ≤ 300 l ≤ 100 ≤ 100 x 4 12 x 2 - Q y 2 - l ≤ 300 ≤ 300 l ≤ 100 - x 3 x 2 - S y 1 - l ≤ 90 l ≤ 50 - x 2 x 1 - y 1 - l ≤ 40 l ≤ 20 - x, y - transducer cable length l - max. length of extension cable 32 TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x Transducer Cable Technical Data type connection system standard length max. length ambient temperature properties 1699 m see table above m °C -55...+200 transducer cable 2550 (option IP68) 6111 -40...+100 longitudinal water tight -100...+225 extension cable 2551 2615 AS TS 1 10 see table above -25...+80 -40...+70 halogen free fire propagation test according to IEC 60332-1 combustion test according to IEC 60754-2 sheath material outer diameter cable jacket material outer diameter thickness color shield mm mm mm stainless steel 304 (1.4301) option OS: 316L (1.4404) 8 - stainless steel 304 (1.4301) option OS: 316L (1.4404) 8 PTFE 2.9 0.3 brown x PUR 5.2 ±0.2 0.9 gray x PFA 2.7 0.5 white x TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 - - - - - TPE-O 8 PUR 12 2 black x black x 33 FLUXUS® F70x Technical Specification Junction Box Technical Data technical type dimensions JB01S4E3M see dimensional drawing wall mounting, optional: 2 " pipe mounting fixation material housing gasket degree of protection according to IEC/ EN 60529 ambient temperature min. °C max. °C explosion protection zone marking JB03 see dimensional drawing wall mounting, optional: 2 " pipe mounting JBP2 see dimensional drawing wall mounting, optional: 2 " pipe mounting stainless steel 316L stainless steel 304 (1.4404) (1.4301) option OS: 316L (1.4404) silicone silicone IP67 IP67 stainless steel 304 (1.4301) option OS: 316L (1.4404) silicone IP67 stainless steel 316L stainless steel 316L (1.4404) (1.4404) silicone IP67 silicone IP67 -40 +80 -40 +80 -40 +80 -40 +80 -40 +80 2 - 2 - 1 0637 II2G II2D Ex e mb IIC (T6)...T4 Gb Ex tb IIIC T 100 °C Db Ta -40...+(70)80 °C IBExU06ATEX1161 IECEx IBE 08.0006 gas: • increased safety • decoupled network: encapsulation dust: protection by enclosure A T E X / I certification ATEX E certification IECEx C type of protection E x JB02 see dimensional drawing wall mounting, optional: 2 " pipe mounting II3G Ex nA IIC (T6)...T4 Gc II3D Ex tc IIIC T 100 °C Dc Ta -40...+(70)80 °C gas: non sparking dust: protection by enclosure JBP3 see dimensional drawing wall mounting, optional: 2 " pipe mounting II3G Ex nA IIC (T6)...T4 Gc II3D Ex tc IIIC T 100 °C Dc Ta -40...+(70)80 °C - gas: non sparking dust: protection by enclosure - Dimensions 156 174 wall mounting holder Ø 70 163.5 9 2 119 thread: 3x M20 x 1.5 cable gland: max. 2x M20 in mm 34 TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x 2 " Pipe Mounting Kit (optional) Terminal Assignment JB01 K L 2 R R S V S V T R T G T R S T V S T G T V transducers K L 1 terminal strip KL1 terminal V VS RS R cable gland connection transducer , signal transducer , internal shield transducer , internal shield transducer , signal external shield shield terminal extension cable terminal strip KL2 terminal TV TVS TRS TR shield terminal equipotential bonding terminal (at wall mounting holder) connection signal internal shield internal shield signal external shield JB02, JB03 terminal XV XR cable gland connection transducer , SMB connector transducer , SMB connector external shield T R T R S T G T G T V S T V transducers K L 2 X V X R shield terminal extension cable terminal strip KL2 terminal TV TVS TRS TR shield terminal connection signal internal shield internal shield signal external shield JB02: equipotential bonding terminal (at wall mounting holder) TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 35 FLUXUS® F70x Technical Specification JBP2, JBP3 K L 2 T R T V S T R S T V T R S T R T G T G T V S T V transducers K L 1 shield terminal JBP2: equipotential bonding terminal (at wall mounting holder) 36 terminal strip KL1 terminal TV TVS TRS TR cable gland connection transducer , signal transducer , internal shield transducer , internal shield transducer , signal external shield extension cable terminal strip KL2 terminal TV TVS TRS TR shield terminal connection signal internal shield internal shield signal external shield TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x Clamp-on Temperature Probe (optional) Technical Data technical type order code PT12N 670415-1 770415-1 design type Pt100 connection measuring range accuracy T °C accuracy ∆T response time housing s degree of protection according to IEC/ EN 60529 weight (without connector) fixation accessories thermal conductivity paste 200 °C thermal conductivity foil 250 °C plastic protection plate, insulation foam dimensions length l width b height h dimensional drawing 2x Pt100 matched according to EN 1434-1 4-wire -30...+250 ±(0.15 °C + 2 . 10-3 . |T [°C]|) class A ≤ 0.1 K (3 K < ∆T < 6 K), more corresponding to EN 1434-1 50 aluminum kg PT12N 770414-1A2 ATEX zone 2 Pt100 2x Pt100 matched according to EN 1434-1 4-wire -30...+250 ±(0.15 °C + 2 . 10-3 . |T [°C]|) class A ≤ 0.1 K (3 K < ∆T < 6 K), more corresponding to EN 1434-1 50 aluminum IP66 0.25 0.5 clamp-on 0.25 0.5 PT12F 670415-2 PT12F 670414-2 short response time Pt100 2x Pt100 matched according to EN 1434-1 4-wire -50...+250 ±(0.15 °C + 2 . 10-3 . |T [°C]|) class A ≤ 0.1 K (3 K < ∆T < 6 K), more corresponding to EN 1434-1 8 PEEK, stainless steel 304 (1.4301), copper IP66 0.32 0.64 clamp-on clamp-on 670415-1: x 770415-1: x 670414-1: x 770414-1: x - x x x - - - x 15 15 20 C 14 30 27 B - 2 - - -30 +250 - mm mm mm 15 15 20 670415-1: A 770415-1: C 670414-1: A 770414-1: C l II3G Ex nA IIC T6...T2 Gc Ta -30...+250 °C extension cable l h B PT12N 770415-1A2 IP66 explosion protection zone explosion protection temperature A min. °C T max. °C E X marking A PT12N 670414-1 770414-1 h l C h junction box extension cable C TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 37 FLUXUS® F70x Technical Specification Connection Temperature Probe red/blue red white/blue white Connector pin 1 2 3, 4, 5 6 7 8 cable of temperature probe white/blue red/blue not connected red white not connected extension cable blue gray 2 4 1 red white 5 8 6 3 7 Cable type standard length max. length m cable of temperature probe 4 x 0.25 mm² black or white 3 extension cable LIYCY 8 x 0.14 mm² gray 5/10/25 m - 200 PTFE PVC JBT2 see dimensional drawing wall mounting optional: 2 " pipe mounting JBT3 see dimensional drawing wall mounting optional: 2 " pipe mounting stainless steel 304 (1.4301) silicone IP67 stainless steel 304 (1.4301) silicone IP67 max. 2x M12 max. 2x M12 -40 +80 -40 +80 2 - cable jacket Junction Box technical type dimensions fixation material housing gasket degree of protection according to IEC/ EN 60529 cable gland ambient temperature min. °C max. °C explosion protection zone marking A T E X certification type of protection 38 II3G Ex nA IIC (T6)...T4 Gc II3D Ex tc IIIC T 100 °C Dc Ta -40...+(70)80 °C gas: non sparking, dust: protection by enclosure - TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 Technical Specification FLUXUS® F70x Terminal Assignment JBT2, JBT3 2 1 4 S 2 K L 2 K L 1 shield terminal 4 3 S 1 3 temperature probe terminal strip KL1 terminal 1 2 3 4 connection red red/blue white white/blue extension cable terminal strip KL2 terminal 1 2 3 4 connection red gray white blue JBT2: equipotential bonding terminal (at wall mounting holder) TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01 39 FLUXUS® F70x Technical Specification FLEXIM GmbH internet: www.flexim.com Wolfener Str. 36 e-mail: info@flexim.com 12681 Berlin 40 Germany Subject to change without notification. Errors excepted. Tel.: +49 (30) 93 66 76 60 FLUXUS® is a registered trademark of FLEXIM GmbH. Fax: +49 (30) 93 66 76 80 TSFLUXUS_F7V1-6-1EN_Leu, 2014-06-01