Station ALS Multi 160
Transcription
Station ALS Multi 160
Central Denmark Region (Region Midtylland) FAO Project Department of the New University Hospital (PA-DNU) Hedeager 3 DK-8200 - Aarhus N, Denmark Ne/- Tilbudsfase: 04.03.2013 RFT 73086 - F2-12-00 - DNU - Rørpost 1 Response form, item 2.5 Dear Sir or Madam, We are pleased to participate and apply for tender of 73086 F2‐12‐00 ‐ DNU – Rørpost project. Kindly find hereafter data sheets of offered component Station Type 4 – Auto‐unload to KBA (laboratory) according to description at 3.5.3 PTS statement of work. Yours faithfully Günther Neudeck Sales Export Manager Ing. Sumetzberger GMBH. Leberstr. 108 A‐1110 Vienna Tel.: +43 1 74035 304 Fax: +43 1 74035 300 Mobile: +43 664 627 66 25 E‐mail: g.neudeck@sumetzberger.at Web: http://www.sumetzberger.at VAT No. ATU37204100 Commercial register No. FN 118934 Commercial court: Vienna Ing. Sumetzberger GMBH. A‐5020 Salzburg, Matzenkopfgasse 35 Tel.: 0662 43 03 93 0 Fax: 0662 43 03 93 20 UID.: ATU 37204100, Firmenbuch FN 118934 d. Handelsgericht Wien, DVR‐Nr.: 0608122 8 7 6 5 0 10 20 4 30 40 50 60 70 3 80 90 1 2 100 407 Multi Carrier Receive Tube F F Multi Carrier Send Tube E system bend 160 E 427 lift 160 233 494 motor slide valve 394 system tube 160 944 D 1015 D ejection bend right 160 800 Station ALS Multi C C automatic opening 682 ALS slide B Änd.5: Änd.4: Änd.3: Änd.2: Änd.1: gez.: 12.02.2013 f.parrer Datum Name A B R Rohrpostsysteme A-1110 Wien, Leberstrasse 108, Tel.: +43/1/74035/0, Fax.: +43/1/74035/340 E-Mail: pt.technics@sumetzberger.at / Homepage: www.sumetzberger.at Bemerkung Aarhus University Hospital Projekt: Zeichnungstitel: DIESE ZEICHNUNG IST GEISTIGES EIGENTUM DER Fa. SUMETZBERGER UND GESETZLICH GESCHÜTZT: JEDE UNBEFUGTE BENÜTZUNG, VERVIELFÄLTIGUNG, ÜBERARBEITUNG UND WEITERGABE AN DRITTE IST VERBOTEN, STRAFBAR UND VERPFLICHTET ÜBERDIES ZUM SCHADENERSATZ. KONSTRUKTIVE DETAILS SIND NICHT VERBINDLICH! (URHEBERGESETZ BGBL. NR. 111/1936, 206/1949, 106/1953) Artikelcode: ALS-Multi Carrier Material: Laboratory Normen: 8 7 6 5 DIN ISO 2768 T1 mittel Oberfläche: Oberfläche/Farbe File: ALS-Multi.idw Maßstab: Format: A3 PNEUMATIC TUBE SYSTEMS Automatic Unloading Station 11 PNEUMATIC TUBE SYSTEMS AUTOUNLOAD Station MCT-ALS Advantages Automatic Carrier Unloading • Fully automatic sample unloading • Multi Carrier Transport for sending and receiving • No time consuming manual carrier manipulation • carriers always available at sending stations because of immediate automatic return • Space required: 728 x 682 x 407 mm (h x w x d) at example layout 14 PNEUMATIC TUBE SYSTEMS AUTOUNLOAD Station MCT-ALS 15 PNEUMATIC TUBE SYSTEMS AUTOMATIC UNLOADING WKO “MERCUR ´12” Life Sciences Innovation Award 8 Station ALS Multi 160 Installation and operation manual Version 1.0.5 Note: Ing. Sumetzberger GMBH. reserves the right to do modifications on their products, which serve the technical development of the products. These modifications are not necessarily recorded in each particular case. This documentation and the contained information are recorded and arranged with the necessary diligence, but Sumetzberger takes no guarantee for printing errors or other faults or resulting damages. The brand and products named in this documentation are trademarks or registered trademarks of the particular title holder. Ing. Sumetzberger GMBH. Leberstraße 108 A-1110 Vienna Telephone +43.(0)1.74035 0 Fax +43.(0)1.74035 300 E-mail (Technical support) pt.technics@sumetzberger.at E-mail (Sales) pt.sales@sumetzberger.at Þ Homepage © Copyright 2012 Ing. Sumetzberger GMBH. www.sumetzberger.com CONTENTS Station ALS Multi 160 1 General General description ................................................................................... 4 Technical data .......................................................................................... 6 Function description .................................................................................. 7 2 Data sheet Data sheet - PHA2000 ............................................................................... 9 Data sheet - RFID 2000 ............................................................................. 10 Data sheet - Sensor MHT1-P122................................................................. 11 3 Installation Necessary tools and materials .................................................................... 12 Appliance and mounting dimension ............................................................ 13 Mounting drills .......................................................................................... 16 Mounting – Carrier rack ............................................................................. 17 4 Cabling General - System cable.............................................................................. 18 Station ALS Multi....................................................................................... 19 5 Spare parts Station ALS Multi....................................................................................... 24 Station Lift 160 ......................................................................................... 26 Automatic opening .................................................................................... 27 6 General Safety Instructions Label for devices ....................................................................................... 29 7 Maintenance Manual Station ALS Multi....................................................................................... 30 General 1 - 4 15.11.2012 Station ALS Multi 160 - Version 1.0.5 General General description Model Station ALS Multi Manufacturer Ing. Sumetzberger G.m.b.H Leberstraße 108 A-1110 Vienna General Microprocessor-controlled pneumatic tube station for transport of samples and other pharmaceutical products. The carrier is automatically opened and emptied. Therefore only APA carriers can used. Type of construction Sending and Receiving Station System The carrier passes automatically the lift station above the Station ALS Multi. Following the carrier stops at the two motor slide valves. Only after the carrier is locked into the Station ALS Multi. There will be checked to what kind of carrier it is. In the case of an APA carrier it is automatically opened, emptied and re-sent. In the case of other carriers, they were sent back again without emptying. Station selection The operation is done menu-controlled over a keyboard and a clear text display (individually programmable target numbers and addresses). The keyboard offers the user a 5-digit target selection with an accompanying 16-digit user text. Application Range Lift station with automatical opening Target information Carrier returns after back to its programmed homestation. Control Microprocesser-controlled Power failure The system is built in a way that after a power failure it is self-examining and if necessary self-repairing. System diagnosis A self-disturbance program, a control of the condition of the unit and the course of operation make a safe operation possible Mounting Inndoor at the wall Safety requirements The station was tested according to office- and industry standards. (EMV etc.) Accessories Holding device for carriers Errors and omissions excepted. General 1 - 5 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Carriers Errors and omissions excepted. Following carriers can be used: • RP46004A (Loading dimension 265x110mm) • RP46004C (Loading dimension 265x110 mm) • RP46004I (Loading dimension 330x110 mm) • RP46004J (Loading dimension 330x110 mm) General 1 - 6 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Technical data Model Station ALS Multi Performance The station is designed as a fully automatic dispatch and receiving unit and can only be used as end station. Mechanical features: • self-adjusting maintenance-free gaskets • sturdy mechanism with “soft” drive by V-belts • contactless dimensioned motor Appliance dimensions 728 x 682 x 407 mm (h x b x t) Packing dimensions (h x b x t) Weight gross: 35,5 kg Casing steel cover RAL1013 white Electric Supply The station is supplied by the power supply unit with 30 V Electricity uptake of the station when ready for operation 120 mA Electricity uptake of the station when receiving or sending 1,2 - 1,5 A Electricity limitation of the station 4 A Type of drive / internal Direct current gear motor over V-belt: 30 VDC max 10 A (electricity limitation at 4 A) 2,5 NM 37 RPM/min Noise level Measurement at a distance of 1 meter: Dispatch: max. 66 dbA Receiving: max. 55 dbA Type of control Tableau, SCB 2000, clear text display with keyboard Clock frequency 20 MHz Dispatch and receipt weigth The carrier can maximally be loaded with a capacity of 0,5 kg. Kind of protection according to DIN40050 IP 53 Errors and omissions excepted. Net: 37,5 kg General 1 - 7 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Function description The two positions of the Station ALS Multi and their functions: 2%#%)6% 2%#%)6% 3%.$ 3%.$ 0OS - - 3ENSORFORMONITORINGTHE DISCHARGEOFTHECARRIER Errors and omissions excepted. $ISCHARGEOF FALSECARRIERS - General 1 - 8 15.11.2012 Station ALS Multi 160 - Version 1.0.5 2%#%)6% 2%#%)6% 3%.$ 3%.$ 0OS 0OS - - !UTOMATICALOPENING OFTHECARRIER %*%#4)/. Pos. 1 Arrival / Discharge position Pos. 2 Eject / Dispatch position Errors and omissions excepted. - Data sheet 2 - 9 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Data sheet Data sheet - PHA2000 Model PHA2000 Manufacturer Sumetzberger GmbH Leberstraße 108; 1110 Vienna Using Expansion card: Secure Receive Function Secure carrier receive or pharmacy function: Received carries are stored in the arrival station and they are not ejected automatically. Because of this, sendings are secure from unauthorised users. Authorise users are requested to put in a code or hold the smart card to the control desk to receive the carrier. Measurement 70 x 50 mm Figure Part PLATINE PHA 2000-4 PHARMACY/SECURED REC programmiert QS Errors and omissions excepted. Order No. RP44874-4 Remark PHA2000 circuit board; Extension for Secure Receive Data sheet 2 - 10 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Data sheet - RFID 2000 Model RFID 2000 Manufacturer Sumetzberger GmbH Leberstraße 108; 1110 Vienna Use Extension card: Code Tag Function By equipping the carrier with passive transponder (no battery), called code tags on both ends, all the carries can be receiving there own identification number and so they can be assigned to a determinate station. The consignment back to this “homestation” is possible without entering the address. Because of this only carriers which are registered to the system can be used and not registered carriers cannot be infiltrated into the system. Follow stations can be equipped: DRT110, DRT Front 110 E3S110, MSS110/160, DST160, DST-END160. Technical data Sending frequency: 125 kHz Exciting frequency: 125 kHz Figure Part PLATINE RFID 2000 4-FACH/4-FOLD READER QS Errors and omissions excepted. Order No. RP44873C Remark RFID2000 Circuit board 4times for MSS 160/6" (Extension Code Data sheet 2 - 11 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Data sheet - Sensor MHT1-P122 Model MHT1-P122 Photoelectric proximity switch Manufacturer SICK GmbH Technical data Scanning distance typ. max. Light source Output current IA max. 0 - 50 mm LED, infrared 50 mA Response time Type of connection Enclosure rating Ambient temperaure < 2,5 ms Cable 2 m Housing IP40 Operation -25 ... +50 °C Storage -40 ... +70 °C ABS Housing material Dimension 1 2 3 4 5 6 Connection cable 2 m, 3x 0,25 mm2 Optic axis sensor Optic axis receiver LED function indicator Translucent rearside Mounting slots Part OTS REFLEXIONS-LICHTTASTER MHT1-P122 50 MM MIT HGA PNP-OUT HELLS 1016051 QS Errors and omissions excepted. Order No. RP45204 Remark OTS switch Installation 3 - 12 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Installation Necessary tools and materials Following materials are required for installation and maintenance of the station: Material (* pcs. or * m = Depending on the use of the station and the local situation) 1 1 pcs. pcs. Station ALS Multi Base frame for Station ALS Multi RP46684 RP46621 2 2 1 1 pcs. pcs. pcs. pcs. Platine RFID2000 Platine SCB2000 Platine PHA2000 Relay Box RP44873C RP45760 RP44874-4 RP46481 1 2 pcs. pcs. Station Lift NW160 Motor slide valve NW160 RP32521B RP43838R 4 4 4 4 pcs. pcs. pcs. pcs. Stair bolt M10 x 100 mm Hexagonal nut M10 Washer M10 Dowel Ø 12 mm Q 145052 QM00M10 QS00M10 Q 060012 1 2 pcs. pcs. Sleeve NW160 Hose clamp 160 RP31134 RP31685 * * * * m m pcs. pcs. System cable Tube NW160 Bend NW160, R800 Bend NW160, R1200 K S118 RP30512B RP30341 RP30107 60 4 * mm pcs. pcs. Shrink hose Wire end caps 2,5² blue Adhesive Tangit PVC-U (125 g tube) Adhesive Tangit PVC-U (1 kg box) RP32513 Q 561005 RP32481 RP32482 Tools (+ = These tools are not provided by company Sumetzberger) Tape measure Drilling machine inclucluding drills Screwdriver set Hexagon screw driver set Socket wrench boxes Diagonal cutting nipper (flat cuts) Pliers - Stoko Pliers - Variocrimp (Wago) Iron saw Cable knife Wire stripping pliers Measuring instrument - Multimeter Logic tester Hot air dryer Hole saw Ø40 mm Cable tester Errors and omissions excepted. + + + + + RP32148 RP32146 RP41804 + + + + RP43424 + + RP44138 Installation 3 - 13 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Appliance and mounting dimension Symbol Isometry Station ALS Multi 407 682 240 530 394 728 630 394 51 n160 Part STATION LAU 160x3,2 SCB2000 RAL1013 LINEAR-AUTOUNLOAD STATION Errors and omissions excepted. Order No. RP46684 Remark Station ALS Multi Installation 3 - 14 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Base frame for Station ALS Multi 30 161 153 30 670 30 50 30 50 670 620 Part ALL 160x3,2 GRUNDGESTELL 670x378x153mm St37-2 vzkt 378 25 620 670 Errors and omissions excepted. 328 328 50 328 50 25 328 50 Order No. RP46621 Remark Base frame Installation 3 - 15 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Motor slide valve 160 213,4 106,7 140 141 45 53 132,2 160 437,7 Ø160 Part SHB 160 8PIN CONNECTOR MOTOR SLIDE VALVE INKL.ANTENNE Errors and omissions excepted. Order No. RP43838R Remark Motor Slide Valve incl. Antenna Installation 3 - 16 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Mounting drills Following mounting drills are necessary for the installation of the station. Centre line tube station 300 294 530 47 605 Mounting material for Station 4 pcs. Dowel ∅ 12 mm Order no.: Q 060012 4 pcs. Stair bolt 10x100 mm Order no.: Q 145052 4 pcs. Hexagonal nut M10 Order no.: QM00M10 4 pcs. Washer M10 Order no.: QS00M10 2 pcs. Sleeve NW160 Order no.: RP31134 4 pcs. Hose clamp Order no.: RP31685 Errors and omissions excepted. Installation 3 - 17 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Mounting – Carrier rack Carrier Rack for 5 Carriers. Following measurements are given: Part BA 5x63-132 RAL7001 HÜLSENABLAGE CARRIER RACK SILBERGRAU BA 5x63-132/4" RAL1013 HÜLSENABLAGE CARRIER RACK QS Errors and omissions excepted. Order No. RP30798 Remark Carrier Rack grey(RAL7001) RP30798W Carrier Rack white(RAL1013) Cabling 4 - 18 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Cabling General - System cable When preparing the system cables of the station, please pay attention to the following: • Strip insulation of the outer cover of the system cable and the impact resistant sheet lying beneath to 150mm. • Strip the insulation of the outer cover of the system cable and the impact resistant sheet of the data cable (0,22²) to 20mm. Remove the sheet screen. Wrist the screen wire and shrink it with a shrink hose 0,5-1mm (Mat.No.RP32513) over the whole length. The wires of the bus cable (0,22²) are entered according to the color code into the 5-pole Stoko-plug (Order no.RP32811). The plug is compressed with pliers. (Order no.:RP32146) • Afterwards the outstanding wires are precisely cut with a diagonal cutting nipper (Order no.:RP32148) at the side edges of the plug. (Attention: the used diagonal cutting nipper has to have a flat cutting edge, since outstanding cables may cause errors.) • The two remaining power supply wires (2,5²) are shortened by 30mm, Strip their insulation on a length of 10mm. • The wire end caps with a collar of synthetic material in blue -2,5²- (Mat.No.Q561005) are put over the cable ends and pressed with Variocrimp pliers 4 (WAGO). (Order No.: RP41804) The above description applies to all system cables in the Sytem MP10.000 Errors and omissions excepted. Cabling 4 - 19 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Station ALS Multi Schematic cabling Station ALS Multi tube switch X5 to blower Relay box Lift Station tube switch X4 Motor slide valve NW160 SCB tube switch X6 Motor slide valve NW160 SCB tube switch X5 Basket full sensor tube switch X5 Basket full sensor Station ALS Multi SCB Reed X2 DCB DISPATCH Detail Station ALS Multi Reed X1 RECEIVE tube switch X6 Basket full sensor Motor tube switch X4 Swivel arm Automatic opening tube switch X6 Automatic opening Swivel arm tube switch X5 Basket full sensor SCB Reed X2 DCB DISPATCH Reed X1 RECEIVE tube switch X6 Basket full sensor Motor tube switch X4 Automatic opening tube switch X6 Automatic opening Swivel arm Errors and omissions excepted. Swivel arm Cabling 4 - 20 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Cabling Station ALS Multi For a secure operation of the station the system cable A (A=incoming cable) as in chapter 4 page 1 has to be prepared. The connection of the cable must not be done under voltage. Part 1 - Automatic opening, Swivel arm and Lift Station PHA2000_1 Errors and omissions excepted. Cabling 4 - 21 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Part 2 - DCB, Tube switches and Reed sensor Errors and omissions excepted. Cabling 4 - 22 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Cabling Seperator (Lift, Motor slide valve) For a secure operation of the station the system cable A (A=incoming cable) as in chapter 4 page 1 has to be prepared. The connection of the cable must not be done under voltage. PHA2000_1 Pin 3 Pin 5 K E0419 red K E0410 blue Errors and omissions excepted. K E0411 brown K E0419 red K E0419 red K E0411 brown K E0412 black K E0412 black K E0419 red Pin 4 Pin 4 Pin 1 Pin 3 Pin 5 Pin 2 Pin 2 Pin 5 Pin 3 Pin 1 Pin 4 Cabling 4 - 23 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Cabling SCB and Motor slide Valve For a secure operation of the station the system cable A (A=incoming cable) as in chapter 4 page 1 has to be prepared. The connection of the cable must not be done under voltage. Errors and omissions excepted. Spare parts 5 - 24 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Spare parts Station ALS Multi 3 1 2 4 5 6 7 8 8 8 9 Errors and omissions excepted. 8 Spare parts 5 - 25 15.11.2012 Station ALS Multi 160 - Version 1.0.5 No. Part Order No. 1 MOTOR 100.606,24VDC,2.5NM,37UM 10 WATT RP31166 TYPE (DRT,W3F) QS 2 PLATINE DCB 2000/2 (DIVERTER CONTROLLER) RP45766 STEUERRECHNER MOT.IC/CIRCUIT BOARD QS 3 PLATINE PHA 2000-4 PHARMACY/SECURED REC RP44874-4 programmiert 4 KOPPELRELAIS 10A 24V DC 1W 40.31 V K535214 5 6 7 8 9 LIFT RITZEL LAGERBOLZEN 10,10,L=26mm RP1417 PA6+25%GF;INKL:NACHARBEIT; QS SPANNSTIFT DIN1481 5X28 GEPR BN876/132917 REEDSCHALTER SCHWARZ 59025-2-V-05A/0,22 HAMLIN PRALLPOLSTER für RP-STATIONEN BG komplett 30x30mm M& LAS FÜHRUNGSSCHIENE l=500mm QS Errors and omissions excepted. Remark Motor (DRT, W3F) 24VDC; 2.5Nm 37min-1 10W circuit board 2000/2 Platine PHA2000 Coupling relay RP32587 Lift pinion bearing pin QL00528 Locking pin DIN1481 5x28 RP32767H Reed switch black RP45747B cushion RP46656H slide rail Spare parts 5 - 26 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Station Lift 160 1 2 3 5 4 No. Part Order No. Remark RP45204 OTS switch 1 OTS REFLEXIONS-LICHTTASTER MHT1-P122 50 MM MIT HGA PNP-OUT HELLS 1016051 QS RP32602 Lift construction grp. 2; belt 2 LIFT BAUGRUPPE 2 RIEMENTRIEB LINKS RP1582 NW63-160 QS drive left 3 LIFT BAUGRUPPE 3 RIEMENTRIEB RECHTS RP32603 Lift construction group. 3; belt RP1583 NW63-160 QS drive right 4 LIFT BAUGRUPPE 4 160 RP32604-160 Lift CG 4 Ground plate + motor GRUNDPLATTE+MOTOR RP2651 unit 5 AL 160x3,2 LIFT ZAHNSTANGE M-2 20x20mm RP46620M toothed rack l=300mm l=300mm Errors and omissions excepted. Spare parts 5 - 27 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Automatic opening 2 4 2 1 8 3 1 6 5 7 No. 1 2 3 4 5 6 7 8 Part ADERNENDHÜLSE 0.5 weiss/ISOL. WIRE END CAP Verp = 100Stk ADERNENDHÜLSE 0.75 grau/Isoliert Gesamtlänge=14mm Verp = 100Stk ADERNENDHÜLSE 0,25 ISOL. 167/H WIRE END CAP Verp = 100Stk SENKSCHRAUBE DIN 965A M 4X12 VERZINKT 0048 4 12 Scheibe DIN 125 A M 4 VZKT Beilagscheibe M 4 VZKT E03462 APA 160 LADEROHR HEBELSTÜTZE (RP43297A) APA 160 FÜHRUNGSBLOCK Order No. Q 561001 Remark Wire end caps 0.5mm Q 561002 Wire end caps 0.75mm Q 561022 Wire end caps 0.25mm Q230412 RP43067C Countersunk screw DIN965 M4x12 Attaching disk DIN125A M4 zincplated sley tube bracket RP43067D sley tube track OTS REFLEXIONS-LICHTTASTER MHT1-P122 50 MM MIT HGA PNP-OUT HELLS 1016051 QS RAU 160/6" ÖFFNUNGSMECHANIK SENSORMECHANIK (ANKUNFT VON OBEN) OTS REFLEXIONS-LICHTTASTER WTB140-P132 11x20x31mm PNP-OUT 10-30VDC 2-500mm APA SPEICHER BG HEBEL KOMPLETT ÖffnungsAutomatik RP45204 OTS switch RP46044 opening mechanic RP46027 OTS reflective switch RP41052C lever automatic opening Errors and omissions excepted. QS00M04 General Safety Instructions 6 - 28 15.11.2012 Station ALS Multi 160 - Version 1.0.5 General Safety Instructions Before putting the pneumatic tube system into service, please read the users manual carefully. The system may only be used by persons who are acquaint to the system. Please keep the manual for a later use. Don’t try to maintain or repair the system by your own. Opening Casings and covers may lead to exposed voltage keeping or mechanical (mobile) parts of the devices. Caution! Leave maintenance works to a qualified service department. Never grasp into the tube openings of the station with your hands. Keep station doors closed all the time. Caution: Risk of getting hurt. Take care, not to get foreign objects into the pneumatic tube station. Avoid liquids and moisture near the station. If there is a undesired material or liquid in the station, please shut down the system and inform your qualified service department. Avoid magnetic fields in the stations area. The system is exclusively designed for the sending of suitable Carriers. Please use only Co. Sumetzberger carriers. CAUTION: Electronic parts contain CMOS components. Don’t touch with your fingers. surrounding temperature: 0-50°C. Errors and omissions excepted. General Safety Instructions 6 - 29 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Label for devices CAUTION Only to be used by trained and authorized persons. CAUTION Risk of getting hurt. Never grasp into the tube openings of the station with your hands. If this label is needed, it can be ordered with the order number RP45222 from Sumetzberger. Errors and omissions excepted. Maintenance Manual 7 - 30 15.11.2012 Station ALS Multi 160 - Version 1.0.5 Maintenance Manual Station ALS Multi Preventive maintenance is a schedule of planned maintenance actions aimed at the prevention of breakdowns and failures before it actually occurs and enhance equipment reliability by replacing worn components before they actually fail. ATTENTION Preventive maintenance works have to be carried out every three month ! Cleaning • Clean inside and outside of the station using synthetic cleaner "Exakt EXTRA". CAUTION Do not spray the cleaner on the circuit board or connectors, because the circuit board will be destroyed! Mechanical tests • Adjust slide valve position. Test function of slide valve • Check function and ease of steering of the revolving part inside the station disassembling and cleaning • Check positioning switches • Adjust positioning of station • Check contact and tight seat of every solder point, plug in connection and clamp • Check tight seat of the motor devices • Check V-belt (increase tension if necessary) • Check mounting, function and examine mechanical damages of the whole station • clean the whole station • Initiate self -test Electrical tests • Operational check of the tube switch for changing direction (between sucking-blowing) • Check function of tube switch (LED lights green as soon as tube switch detects) • Check (measure) positioning switches • Check (measure) motor current • Check (measure) source voltage (idle motion and under load) Errors and omissions excepted.