PRODUCTS RANGE | ENGLISH
Transcription
PRODUCTS RANGE | ENGLISH
> PRODUCTS RANGE | ENGLISH The PRAMAC Group represents a solid industrial reality, from manufacturing to commercialization. Its strong international presence has been consolidated in the generators and material handling markets, through an aggressive growth that has found place in the most varied and demanding markets. PRAMAC is a young and dynamic company, that has projected its development and experience, gained by the merger between different production realities, incorporating all efforts in one single objective: to offer better solutions to our clients. Thanks to the combination between team work, the operational flexibility due to the worldwide commercial and manufacturing presence, and the close bond with sports and its values, PRAMAC introduces a new commercial structure, developed to achieve with best success each market concrete demands. In the generating area, PRAMAC generators bring into the market more than 1.300.000 kVA per year, divided in a power range units from 1 to 2500 kVA, offering solutions for every kind of demand: energy where main supplies are not available and uninterrupted energy where it cannot fail, energy for those working and energy for entertaining. At the same time, PRAMAC offers a professional line of power tools, as high pressure washers, welder generators, PTO generator, motorpumps and illuminating systems, presenting the highest perfomance and reliability. PRAMAC has always dedicated resource and energy to the most demanding markets, as a true symbol of its experience built under one vision: to offer the best cost-benefit relationship, enhanced by a strong strategic relationship with first level components partners. PRO heavy duty is the result of in depth market analysis, where we have identified and recognized specific needs that arise in heavy duty applications, such as construction sites, rental or agricultural locations. For these applications PRAMAC has given priority to endurance, reliability and safety. CONFORMS TO THE EUROPEAN SAFETY RULES The strategic objective to exceed the expectations of the customer can only be reached if the products are of the highest possible quality. The PRAMAC Group has taken this on in its philosophy in production. The continual improvement in the company processes, formulated with absolute respect for the environment and the specialised training of its staff, forms part of the Total Safety and Quality programme that the company sets itself. There is a real Safety and Quality Culture inside the company, starting from respect for the environment and regard for the specific regulations. Concrete evidence of this commitment is the certifications that the company has obtained on both the European level and extra-European level. Special offer on an engine kit On-line spare parts order and interactive spare parts catalogues Planned preventive maintenance Personalised solutions with 24/7 on call service Service support Installations and commissioning Training program Dedicated training program for users, maintenance, and after sales service SERVICE AND PARTS PRAMAC Service and Parts represents PRAMAC's commitment to Customer Care and Satisfaction. The creation of a highly specialised business unit, completely devoted to After Sales Customer Service, proves the PRAMAC intent to support its Customers at every stage of the professional relationship. On top of this, an incredible wide range of spare parts and components, with highly trained, professional staff, is what the PRAMAC Service and Parts division offers, answering requests from Customers all around the world. Attention to detail and consideration of users requirements is the core of an efficient after sales service. The focus and motto of the Service and Parts division is: Our Customers are Our First Priority. Our activity is the corner stone that makes our products valuable. For this reason we develop special actions for our dealer customers and end users, giving support through schedule maintenance programs, installation and commisioning services, training activities, and a constant, active support through our website: www.pramacparts.com PRODUCT RANGE INDUSTRIAL GENERATORS OPEN SET PORTABLE GENSET & POWER EQUIPMENT GBA 6-17d pag. 8 ES SERIES pag. 56 GSA 22-65d pag. 10 S SERIES pag. 58 GBW 15-45p / y pag. 12 SP SERIES pag. 62 GSL 30-42d pag. 14 P SERIES pag. 64 GSW 65-170d pag. 16 W SERIES pag. 68 GSW 195-220d pag. 18 GSW 530-560d pag. 20 HIGH PRESSURE WASHERS GSW 275-590V pag. 22 ZG SERIES WELDER GENERATOR PW SERIES pag. 70 pag. 71 PTO SHAFT GENERATOR MP SERIES INDUSTRIAL GENERATORS SOUNDPROOF pag. 72 PRESSURE WASHER GBL 30-42d pag. 24 LIGHT GLOBE pag. 73 GSL 30-42d pag. 26 LIGHT TOWER pag. 74 GBW 15-45p / y pag. 28 HE SERIES pag. 75 GBW 65-110p pag. 30 GSW 15-22p pag. 32 GSW 15-22d pag. 34 GSW 65-170d pag. 36 GSW 195-220d pag. 38 GSW 530-560d pag. 40 GSW 275-590V pag. 42 HOIST ELECTRICAL EQUIPMENT CUSTOMISED SOLUTIONS GPW SERIES pag. 46 GCW UNITS pag. 54 AMF pag. 77 PANELS pag. 78 1 3 6 9 12 15 20 30 45 65 80 110 145 170 195 220 275 330 415 450 510 590 1500 2500 kVA GBA Deutz/Lombardini Series GBW Perkins/Yanmar Series GSA Deutz/Lombardini Series INDUSTRIAL GENSETS GSL Deutz Series Standard Solutions GSW Deutz Series GSW Volvo Series GSW Deutz/Perkins Series GBL Deutz Series INDUSTRIAL GENSETS GSW Volvo Series Standard Solutions GBWPerkins/Yanmar Series GBW Deutz Series GSW Deutz Series GPW - Special Solutions INDUSTRIAL GENSETS GCW - Customised Solutions Customised Solutions ES Class S Class PORTABLE GENSETS P Class SP Class POWER EQUIPMENT 30 30 - 220 A Semi Pro Pro OPENSET SOUNDPROOF PORTABLE CUSTOMISED Power (LTP) 8 - 32 kVA (three phase) Flow 600 - 1340 l/min (Semi trash & Trash) Welding current range 170 - 220 A Pressure from 110 - 240 bar 250 - 2000 W (25.500 - 189.000 lumen) 51.700 lm (Portable genset) - 200.000 lm (Stationary genset) load to 125/ 200/ 500 Kg PTO GENERATORS MOTOR PUMP WELDER GENERATORS HIGH PRESSURE WASHERS LIGHTGLOBE LIGHT TOWER HOIST INDUSTRIAL GENERATORS OPEN SET GBA 6d-17d GBA SERIES ENERGY FOR ALL YOUR NEEDS The GBA series are the simplest way to fulfill particular power demands. The high quality components make these generators very reliable and easy to use. They are also ideal for starting and powering motor pumps. High autonomy fuel tank Efficient air filtration systems Rated battery capacity Fuel tank integrated on engine GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h GBA6d GBA12L GBA14d GBA17d three phase three phase three phase three phase 4,7/5,9 4,5/5,6 400 50 3 9,1/11,3 8,2/10,2 400 50 3 10,7/13,4 10,2/12,8 400 50 3 13,0/16,2 12,01/15,1 400 50 3 Deutz D909 L1 Diesel 1 710 Natural Air Electric 1500 Mechanical 5,8 5,5 2,1 NA 1,14 1,53 12 Lombardini 9LD 625 Diesel 2 in line 1248 Natural Air Electric 1500 Mechanical 10,7 9,6 2,8 NA 2,4 3,2 12 Deutz F2L2011 Diesel 2 in line 1550 Natural Air Electric 1500 Mechanical 12,6 12 6 NA 2,57 3,43 12 Deutz D910L2 Diesel 2 in line 1650 Natural Air Electric 1500 Mechanical 15,1 14 4 NA 3,01 4,02 12 Linz E1S13 S/4/7,5 4 7,42 81,3 Compound Linz E1S13 S/4/11 4 11,6 84,8 Compound Linz E1S13 M/4/13 4 13,8 85,4 Compound Linz E1S13 M/4/16 4 17 86,3 Compound 1226 700 960 267 14,5 12,67 1226 700 960 244 10 4,17 1400 750 1180 468 91 35,39 1226 700 1060 420 50 16,6 Panels - MCP Analogue n° 1, pag. 78 9 INDUSTRIAL GENERATORS OPEN SET GSA 22d-65d GSA SERIES CONSTANT POWER SUPPLY The GSA generators provide peace-of-mind: with a greatly extended running time, these sets offer a professional solution against main power failures, maintaining a constant power supply. Accessories Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Connection kit for communication via Modem / GSM (only for automatic versions) Load Transfer Switch Panel (LTS) for ACP versions Single phase version Residential silencer Flexible exhaust compesator Engine electronic governor Load Transfer panel Highly efficient alternator Steel base frame with bolted support legs Wide range of accesories GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h (1) GSA22d GSA30d GSA42d (1) GSA65d (1) three phase three phase three phase three phase 16,2/20,2 15,2/19,0 400 50 3 24,0/30,0 23,2/29,0 400 50 3 32,8/41,0 32,0/40,0 400 50 3 49,7/62,1 48,8/61,0 400 50 3 Deutz F3L2011 Diesel 3 in line 2330 Natural Air Electric 1500 Mechanical 20 19 5,5 NA 3,58 4,78 12 Deutz F4L2011 Diesel 4 in line 3110 Natural Air Electric 1500 Mechanical 29 27,6 10 NA 5,27 7,03 12 Deutz F4L912 Diesel 4 in line 3770 Natural Air Electric 1500 Mechanical 38 37 11 NA 7,07 9,43 12 Deutz F6L912 Diesel 6 in line 5650 Natural Air Electric 1500 Mechanical 56 55 13,5 NA 10,51 14,01 12 Linz E1S13 M/4/19 4 20,14 86,5 Compound Stamford BCI 184F 4 30 85,8 Electronic Stamford BCI 184J 4 45 86,6 Electronic Stamford UCI 224E 4 63 88,8 Electronic 1400 750 1700 510 90 25,12 1400 750 1700 655 90 17,08 1800 750 1710 776 90 12,73 2200 1000 1620 954 240 22,84 This Generator is normally intended to be used for industrial application only. In this case, its engine would not have to comply with EU 97/68/EC Stage II (EU2007) Directive (no need for subsequent modifications and/or integrations). Panels - MCP Digital n° 2, pag. 78 - MCP Analogue n° 3, pag. 78 - ACP n° 4, pag. 78 11 INDUSTRIAL GENERATORS OPEN SET GBW 15-45p/y GBW SERIES POWER AND VERSATILITY The GBW Series are reliable and powerful machines designed for professional use in construction sites and other industrial applications. With an excellent performance and easy installation they can be used either to support electricity mains failure or isolated locations. Accessories Coolant pre-heating system (for automatic start) Load Transfer Switch Panel (LTS) for ACP versions Single phase version Load Transfer panel Standard socket combination Fuel filter Water radiator cap GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h GBW15p GBW15y GBW22p GBW22y GBW30p GBW30y GBW45p GBW45y three phase three phase three phase three phase three phase three phase three phase three phase 11,0/13,8 10,1 / 12,7 400 50 3 11,04 / 13,8 10,4 / 13,0 400 50 3 16,1 / 20,1 15,2 / 19,0 400 50 3 16,1 / 20,1 15,2 / 19,0 400 50 3 24,0 / 30,0 23,2 / 29,0 400 50 3 26,4 / 33,0 26,0 / 32,5 400 50 3 36,0 / 45,0 35,2 / 44,0 400 50 3 36,0 / 45,0 35,2 / 44,0 400 50 3 Perkins 403C-15G Diesel 3 in line 1496 Natural Water Electric 1500 Mechanical 13,3 12,0 6,0 6,0 2,7 3,6 12 Yanmar 3TNV88 Diesel 3 in line 1642 Natural Water Electric 1500 Mechanical 14,5 13,2 6,7 2,0 2,8 3,7 12 Perkins 404C-22G Diesel 4 in line 2216 Natural Water Electric 1500 Mechanical 20,3 18,4 10,6 7,0 3,8 5,1 12 Yanmar 4TNV88 Diesel 4 in line 2190 Natural Water Electric 1500 Mechanical 19,5 17,7 10,6 7,0 3,8 5,1 12 Perkins 1103A-33G Diesel 3 in line 3300 Natural Water Electric 1500 Mechanical 30,4 27,7 7,9 10,2 5,1 6,8 12 Yanmar 4TNV98 Diesel 4 in line 3319 Natural Water Electric 1500 Mechanical 37,5 34,1 10,5 4,2 6,1 8,1 12 Perkins 1103A-33TG1 Diesel 3 in line 3300 Natural Water Electric 1500 Mechanical 45,6 41,3 7,9 10,2 7,8 10,4 12 Yanmar 4TNV98T Diesel 4 in line 3319 Natural Water Electric 1500 Mechanical 45,5 41,4 10,5 4,2 8,7 11,6 12 Linz E1S13 M/4/19 4 20,1 86,5 Compound Linz E1S13 M/4/19 4 20,1 86,5 Compound Stamford BCI 184F 4 30,0 85,8 Electronic Stamford BCI 184G 4 33,0 85,8 Electronic Stamford BCI 184J 4 45,0 86,6 Electronic Stamford BCI 184J 4 45,0 86,6 Electronic 1600 870 1000 480 51 13,3 1600 870 1000 408 51 13,3 2000 920 1100 700 51 10,0 2000 920 1100 583 51 8,4 2000 920 1100 785 51 6,5 2000 920 1100 673 51 5,9 Linz Linz E1S13 M/4/13 E1S13 M/4/13 4 4 13,8 13,8 85,4 85,4 Compound Compound 1600 870 1000 410 51 18,7 1600 870 1000 280 51 18,3 Panels - MCP n° 5, pag. 79 - ACP n° 6, pag. 79 13 INDUSTRIAL GENERATORS OPEN SET GSL 30d-42d GSL SERIES AN ALTERNATIVE POWER SUPPLY Great performance from these oil cooled engine generators, offering reliable power with easy installation. The GSL series are perfect for locations not connected to a main power supply. ALSO FOR BIODIESEL 100% Accessories Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Connection kit for communication via Modem / GSM (only for automatic versions) Single phase version Residential silencer Flexible exhaust compesator Engine electronic governor Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Integrated oil cooling system Industrial silencers Replaceable cartridge air filter Optimized anti-vibration pads GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h GSL30d GSL42d three phase three phase 24,0/30,0 23,2/29,0 400 50 3 33,0/41,3 31,5/39,3 400 50 3 Deutz F4M2011 Diesel 4 in line 3110 Natural Oil Electric 1500 Mechanical 29 27,6 10 NA 5,32 7,09 12 Deutz BF4M2011 Diesel 4 in line 3110 Turbo Oil Electric 1500 Mechanical 38,2 36,4 10 NA 7,05 9,4 12 Stamford BCI 184F 4 30 85,8 Electronic Stamford BCI 184J 4 45 86,6 Electronic 1800 750 1720 714 90 16,92 1800 750 1720 761 90 12,76 Panels - MCP Digital n° 2, pag. 78 - MCP Analogue n° 3, pag. 78 - ACP n° 4, pag. 78 15 INDUSTRIAL GENERATORS OPEN SET GSW 65d-170d GSW SERIES ENERGY FOR PUBLIC AND INDUSTRIAL USES I The GSW range is available with a range of accessories providing a versatile solution to a variety of applications e.g. to support Telecommunications sites. Accessories Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Connection kit for communication via Modem / GSM (only for automatic versions) Single phase version Residential silencer Flexible exhaust compesator Engine electronic governor Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Steel base frame with bolted support legs Latest technology electronic devices Avaibility of different cubicle solutions Battery GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h (1) GSW65d GSW80d GSW110d GSW145d (1) GSW170d three phase three phase three phase three phase three phase 50/63 46/58 400 50 3 64/80 62/77 400 50 3 86/108 82/102 400 50 3 113/142 108/135 400 50 3 134/167 127/159 400 50 3 Deutz BF4M2012 G2 Diesel 4 in line 4040 Turbo Water Electric 1500 Mechanical 58 52 8,5 15,9 10,26 13,68 12 Deutz BF4M2012C Diesel 4 in line 4040 Turbo, CAC Water Electric 1500 Mechanical 79,7 70,7 8,5 17,9 13,31 17,74 12 Deutz BF4M1013EC Diesel 4 in line 4760 Turbo, CAC Water Electric 1500 Mechanical 96,1 91,1 11 19,7 16,67 22,23 12 Deutz BF6M1013E Diesel 6 in line 7150 Turbo Water Electric 1500 Mechanical 123,8 117,8 20 23,1 21,88 29,17 12 Deutz BF6M1013EC Diesel 6 in line 7150 Turbo, CAC Water Electric 1500 Mechanical 145,1 138,1 20 23,1 24,54 32,72 12 Stamford UCI 224E 4 63 88,8 Electronic Stamford UCI 224F 4 80 89,9 Electronic Stamford UCI 274C 4 110 90,3 Electronic Stamford UCI 274E 4 150 91,7 Electronic Stamford UCI 274F 4 175 92,3 Electronic 2200 1000 1620 865 240 23,39 2200 1000 945 TBA 240 18,04 2200 1000 1620 1326 240 14,39 2600 1000 1620 1545 250 11,43 2600 1000 1620 1615 250 10,19 This Generator is normally intended to be used for industrial application only. In this case, its engine would not have to comply with EU 97/68/EC Stage II (EU2007) Directive (no need for subsequent modifications and/or integrations). Panels - MCP Digital n° 2, pag. 78 - MCP Analogue n° 3, pag. 78 - ACP n° 4, pag. 78 17 INDUSTRIAL GENERATORS OPEN SET GSW 195d-220d GSW SERIES ENERGY FOR PUBLIC AND INDUSTRIAL USES II With a wide range of accessories these generators are able to satisfy the requirements of many different applications. Exceptional load acceptance characteristics and constant voltage output is guaranteed due to the electronic governor which is installed as standard. Accessories Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Connection kit for communication via Modem / GSM (only for automatic versions) Residential silencer Flexible exhaust compesator Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Highly efficient alternators Hot parts protection Long autonomy fuel tanks Air filter indicator GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h GSW195d GSW220d three phase three phase 155/194 149/186 400 50 3 176/220 166/208 400 50 3 Deutz BF6M1013FCP G2 Diesel 6 in line 7150 Turbo intercooler Water Electric 1500 Electronic 178,6 161,6 20 27,3 32,9 43,86 24 Deutz BF6M1013FCP G3 Diesel 6 in line 7150 Turbo intercooler Water Electric 1500 Electronic 196,6 178,6 20 27,3 36,84 49,12 24 Stamford UCI 274G 4 194 92,4 Electronic Stamford UCI 274H 4 220 93,3 Electronic 2650 1100 1965 1980 410 12,46 2650 1100 1980 1964 410 11,13 Panels - MCP Digital n° 2, pag. 78 - MCP Analogue n° 3, pag. 78 - ACP n° 4, pag. 78 19 INDUSTRIAL GENERATORS OPEN SET GSW 530d-560d GSW SERIES POWERFUL GENERATION This family of generators offers the best perfomance under the most difficult and variable operation conditions. Ideal for major industrial areas that need an extra power source. Accessories Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Connection kit for communication via Modem / GSM (only for automatic versions) Residential silencer Flexible exhaust compesator Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Terminal board load connection Electronical controlled engine Moving and rotating parts protection Set of documentation available GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h GSW530d GSW560d three phase three phase 422/528 367/459 400 50 3 437/546 407/509 400 50 3 Deutz Deutz BF8M1015C G2 BF8M1015CP Diesel Diesel 8V 8V 15900 15900 Turbocharged intercooler Turbocharged intercooler Water Water Electric Electric 1500 1500 Electronic Electronic 449,7 475,9 391,3 433,9 45 45 102 116 72,32 85,62 96,43 114,16 24 24 Mecc-Alte ECO40 3S/4 4 546 94,2 Electronic Mecc-Alte ECO40 3S/4 4 546 94,2 Electronic 3300 1800 2135 3600 636 8,79 3300 1800 2135 3750 636 7,43 Panels - ACP n° 8, pag. 79 21 INDUSTRIAL GENERATORS OPEN SET GSW 275V-590V GSW SERIES POWER IN ISOLATION A continuous power supply, provided by high power output and extended running time, makes this range of generators the most suitable for powering sites not connected to a mains power supply. This range is also ideal for running lighting systems during power failures. Accessories Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Connection kit for communication via Modem / GSM (only for automatic versions) Residential silencer Flexible exhaust compesator Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Well balanced engine block 6 in line cilinders Efficiency in noise attenuation Manual oil drain pump Synchronous brushless alternators 1% voltage regulation GSW275V GSW330V GSW415V GSW450V GSW510V GSW560V GSW590V three phase three phase three phase three phase three phase three phase three phase GENERATING SET STAND BY POWER LTP kW/kVA 220/275 264/330 331/414 350/437 406/507 437/546 481/601 PRIME POWER PRP kW/kVA 202/252 252/315 302/378 329/411 369/461 404/505 457/571 VOLTAGE Volt 400 400 400 400 400 400 400 FREQUENCY Hz 50 50 50 50 50 50 50 PHASES 3 3 3 3 3 3 3 ENGINE MODEL Volvo Volvo Volvo Volvo Volvo Volvo Volvo TYPE TAD734GE TAD941GE TAD1241GE TAD1242GE TAD1640GE TAD1641GE TAD1642GE FUEL Diesel Diesel Diesel Diesel Diesel Diesel Diesel NUMBER AND DISPOSITION OF CYLINDERS 6 in line 6 in line 6 in line 6 in line 6 in line 6 in line 6 in line DISPLACEMENT cc 7150 9360 12130 12130 16120 16120 16120 ASPIRATION Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler COOLING SYSTEM Water Water Water Water Water Water Water STARTING SYSTEM Electric Electric Electric Electric Electric Electric Electric SPEED rpm 1500 1500 1500 1500 1500 1500 1500 SPEED GOVERNOR Electronic Electronic Electronic Electronic Electronic Electronic Electronic STAND BY POWER LTP kW 241 320 354 387 432 473 536 PRIME POWER PRP kW 216 290 323 352 393 430 485 LUBE OIL CAPACITY (MAX) L 29 35 35 35 48 48 48 COOLANT CAPACITY (MAX) L 32 41 44 44 93 93 93 FUEL CONSUMPTION at 75% PRP L/h 39,29 48,45 57,1 62,54 68,07 76,02 87,04 FUEL CONSUMPTION at 100% PRP L/h 52,38 64,61 76,14 83,39 90,76 101,36 116,05 ELECTRICAL CIRCUIT Volt 24 24 24 24 24 24 24 ALTERNATOR MODEL Mecc-Alte Mecc-Alte Mecc-Alte Mecc-Alte Mecc-Alte Mecc-Alte Mecc-Alte TYPE ECO38 1L N4 ECO38 2L N4 ECO40 1S/4 ECO40 1S/4 ECO40 3S/4 ECO40 3S/4 ECO40 1L/4 POLES 4 4 4 4 4 4 4 STAND BY 163/27°C rating - LTP kVA 275 330 437 437 546 546 601 EFFICIENCY at 75% load 93,7 94,1 93,8 93,8 94,2 94,2 94,6 VOLTAGE REGULATION SYSTEM Electronic Electronic Electronic Electronic Electronic Electronic Electronic OVERALL DIMENSIONS AND WEIGHT LENGTH mm 2950 3300 3300 3300 3500 3500 3500 WIDTH mm 1300 1400 1400 1400 1500 1500 1500 HEIGHT mm 1750 1887 1917 1917 2120 2120 2120 WEIGHT Kg 2110 2580 3050 3050 3620 3620 3620 FUEL TANK CAPACITY L 460 636 636 636 636 636 636 RUNNING TIME at 75% PRP h 11,2 13,13 11,14 10,17 9,34 8,37 7,31 Panels - ACP n° 8, pag. 79 23 INDUSTRIAL GENERATORS SOUNDPROOF GBL 30d-42d GBL SERIES THE MULTIPURPOSE GENERATOR I This range has been designed to meet particular market needs. The most suitable application is on construction sites, where durability and reliability are required to supply constant power to applications such as lighting, cranes, concrete mixers and conveyor belts. With low noise emissions, they are also suitable for open air activities, such as shows or sporting events. ALSO FOR BIODIESEL 100% Accessories Load Transfer Switch Panel (LTS) for ACP versions Single phase version Light Tower Site trailer Road trailer-rigid bar Engine electronic governor Coolant pre-heating system (for automatic start) Stacking option while warehousing Visual fuel level External fuel refilling Single fluid for cooling and lubrication GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GUARANTEED SOUND POWER LEVEL LWA dB(A) GBL30d GBL42d three phase three phase 24,0/30,0 23,2/29,0 400 50 3 33,0/41,3 31,5/39,3 400 50 3 Deutz F4M2011 Diesel 4 in line 3110 Natural Oil Electric 1500 Mechanical 29 27,6 10 NA 5,32 7,09 12 Deutz BF4M2011 Diesel 4 in line 3110 Turbo Oil Electric 1500 Mechanical 38,2 36,4 10 NA 7,05 9,4 12 Stamford BCI 184F 4 30 85,8 Electronic Stamford BCI 184J 4 45 86,6 Electronic 2000 920 1300 848 51 9,59 67 92 2000 920 1300 942 51 7,23 67 92 Panels - MCP n° 5, pag. 79 - ACP n° 6, pag. 79 25 INDUSTRIAL GENERATORS SOUNDPROOF GSL 30d-42d GSL SERIES RENTAL ENERGY I This range of generators is suitable for any application. They have all the features associated with PRAMAC Generators; low noise, security, greatly extended running time and versatility in all applications. The perfect choice for rental. ALSO FOR BIODIESEL 100% FULLY BUNDED BASEFRAME Accessories Galvanized skid base frame with integrated driptray and fork lift channels Site trailer Road trailer-rigid bar Socket kit Engine electronic governor Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Rental Kit Single lifting eye Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Connection kit for communication via Modem / GSM (only for automatic versions) Single phase version Light Tower Rental kit Controlled exhaust emissions Detachable canopy panels GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GUARANTEED SOUND POWER LEVEL LWA dB(A) GSL30d GSL42d three phase three phase 24,0/30,0 23,2/29,0 400 50 3 33,0/41,3 31,5/39,3 400 50 3 Deutz F4M2011 Diesel 4 in line 3110 Natural Oil Electric 1500 Mechanical 29,00 27,60 10,00 NA 5,32 7,09 12 Deutz BF4M2011 Diesel 4 in line 3110 Turbo Oil Electric 1500 Mechanical 38,20 36,40 10,00 NA 7,05 9,40 12 Stamford BCI 184F 4 30,00 85,80 Electronic Stamford BCI 184J 4 45,00 86,60 Electronic 2200 920 1300 952 78 14,7 64 89 2000 920 1300 1024 78 11,0 64 89 Panels - MCP Analogue n° 7, pag. 79 - ACP n° 9, pag. 80 - MCP Digital n° 13, pag. 81 27 INDUSTRIAL GENERATORS SOUNDPROOF GBW15-45p/y GBW SERIES FRIENDLY GENERATION Family with optimized features specially focused to meet the needs of low investment applications. Generators of reduced dimensions and weight making it easy to transport and store. Ideal for rental use. Accessories Single phase version Coolant pre-heating system (for automatic start) Site trailer Road trailer-rigid bar Load Transfer Switch Panel (LTS) for ACP versions Long autonomy fuel tanks Pneumatic arm Support legs welded to baseframe Canopy lock GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GUARANTEED SOUND POWER LEVEL LWA dB(A) GBW15p GBW15y GBW22p GBW22y GBW30p GBW30y GBW45p GBW45y three phase three phase three phase three phase three phase three phase three phase three phase 11,1/13,8 10,0 /12,7 400 50 3 11,1/13,8 10,4/13,0 400 50 3 16,1/20,1 15,2/19,0 400 50 3 16,1/20,1 15,2/19,0 400 50 3 24,0/30,0 23,2/29,0 400 50 3 26,4/33,0 26,0/32,5 400 50 3 36,0/45,0 35,2/44,0 400 50 3 36,0/45,0 35,2/44,0 400 50 3 Perkins 403C-15G Diesel 3 in line 1496 Natural Water Electric 1500 Mechanical 13,3 12,0 6,0 6,0 2,7 3,6 12 Yanmar 3TNV88 Diesel 3 in line 1642 Natural Water Electric 1500 Mechanical 14,5 13,2 6,7 2,0 2,8 3,7 12 Perkins 404C-22G Diesel 4 in line 2216 Natural Water Electric 1500 Mechanical 20,3 18,4 10,6 7,0 3,8 5,1 12 Yanmar 4TNV88 Diesel 4 in line 2190 Natural Water Electric 1500 Mechanical 19,5 17,7 10,6 7,0 3,8 5,1 12 Perkins 1103A-33G Diesel 3 in line 3300 Natural Water Electric 1500 Mechanical 30,4 27,7 7,9 10,2 5,1 6,8 12 Yanmar 4TNV98 Diesel 4 in line 3319 Natural Water Electric 1500 Mechanical 37,5 34,1 10,5 4,2 6,1 8,1 12 Perkins 1103A-33TG1 Diesel 3 in line 3300 Natural Water Electric 1500 Mechanical 45,6 41,3 7,9 10,2 7,8 10,4 12 Yanmar 4TNV98T Diesel 4 in line 3319 Natural Water Electric 1500 Mechanical 45,5 41,4 10,5 4,2 8,7 11,6 12 Linz E1S13 M/4/19 4 20,1 86,5 Compound Stamford BCI 184F 4 30,0 85,8 Electronic Stamford BCI 184G 4 33,0 85,8 Electronic Stamford BCI 184J 4 45,0 86,6 Electronic Stamford BCI 184J 4 45,0 86,6 Electronic 1600 870 1072 493 51 13,3 68 93 2000 920 1300 875 51 10,0 68 93 2000 920 1300 758 51 8,4 67 92 2000 920 1300 960 51 6,5 66 91 2000 920 1300 848 51 5,9 67 92 Linz Linz Linz E1S13 M/4/13 E1S13 M/4/13 E1S13 M/4/19 4 4 4 13,8 13,8 20,1 85,4 85,4 86,5 Compound Compound Compound 1600 855 1072 560 51 18,7 71 96 1600 855 1072 430 51 18,3 68 93 1600 870 1072 565 51 13,3 70 95 Panels - MCP n° 5, pag. 79 - ACP n° 6, pag. 79 29 INDUSTRIAL GENERATORS SOUNDPROOF GBW 65p-110p GBW SERIES THE MULTIPLE PURPOSE GENERATOR II Compliant with noise and exhaust emissions regulations, this middle power rating range is designed to meet every kind of application where reliability without any specific or special requirements is needed. Accessories Single phase version Coolant pre-heating system (for automatic start) Socket kit of 5 plugs Site trailer Road trailer-rigid bar Load Transfer Switch Panel (LTS) for ACP versions Control panel behind lockable door Socket kit available Fuel filter Oil drain pipe GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GUARANTEED SOUND POWER LEVEL LWA dB(A) GBW65p GBW80p GBW110p three phase three phase three phase 50,0/63,0 48,0/60,0 400 50 3 64,0/80,0 62,0/77,0 400 50 3 88,0/110,0 80,0/100,0 400 50 3 Perkins 1103A-33TG2 Diesel 3 in line 3300 Turbo Water Electric 1500 Mechanical 59,3 53,8 7,9 10,2 11,0 14,0 12 Perkins 1104A-44TG2 Diesel 4 in line 4400 Turbo Water Electric 1500 Mechanical 79,1 71,9 8,0 13,0 14,0 19,0 12 Perkins 1104C-44TAG2 Diesel 4 in line 4410 Turbo, CAC Water Electric 1500 Electrical 98,0 89,0 8,0 13,0 22,0 30,0 12 Stamford UCI 274 C 4 63,00 88,80 Electronic Stamford UCI 224 E 4 80,00 89,90 Electronic Stamford UCI 224 F 4 110,0 90,3 Electronic 2380 1000 1301 1155 120 11,0 71 96 2380 1000 1301 1285 120 8,0 71 96 2380 1000 1301 1480 120 5,0 71 96 Panels - MCP Analogue n° 10, pag. 80 - ACP n° 11, pag. 80 - MCP Extended n° 14, pag. 81 31 INDUSTRIAL GENERATORS SOUNDPROOF GSW 15p-22p GSW SERIES COMPACT ENERGY I This series provides the most professional way to fulfill small power requirements with highest reliability and excellent performance. Most popular range for residential areas and telecommunication sites. FULLY BUNDED BASEFRAME Accessories Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Connection kit for communication via Modem / GSM (only for automatic versions) Single phase version Rental kit Galvanized skids frame with fork lift channels Site trailer Road trailer-rigid bar Socket kit Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Detachable lifting eye Galvanized skids Lockable door handles Rental optionals available GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GUARANTEED SOUND POWER LEVEL LWA dB(A) GSW15p GSW22p three phase three phase 11,5/14,3 10,3/12,9 400 50 3 17,1/21,4 15,5/19,4 400 50 3 Perkins 403C-15G Diesel 3 in line 1496 Natural Water Electric 1500 Mechanical 13,30 12,00 6,00 5,98 2,72 3,63 12 Perkins 404C-22G Diesel 3 in line 2215 Natural Water Electric 1500 Mechanical 20,30 18,40 10,60 5,98 3,98 5,30 12 Mecc-Alte ECO 3 2L 4 15,00 86,80 Electronic Stamford BCI 184E 4 22,50 84,20 Electronic 1800 830 1300 700 78 28,7 61 86 1800 830 1310 810 78 19,6 61 86 Panels - MCP Analogue n° 7, pag. 79 - ACP n° 9, pag. 80 - MCP Digital n° 13, pag. 81 33 INDUSTRIAL GENERATORS SOUNDPROOF GSW 15d-22d GSW SERIES COMPACT ENERGY II This range is designed for the most competitive markets which require the ability to run many different applications with small power demands. The wide range of accessories, small dimensions, long running and rental versions make them very attractive products. FULLY BUNDED BASEFRAME Accessories Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Connection kit for communication via Modem / GSM (only for automatic versions) Single phase version Rental kit Galvanized skids frame with fork lift channels Site trailer Road trailer-rigid bar Socket kit Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Noise attenuation material Wide range of accesories Manual oil drain pump Terminal block GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GUARANTEED SOUND POWER LEVEL LWA dB(A) GSW15d GSW22d three phase three phase 12,0/15,0 11,5/14,3 400 50 3 16,9/21,1 16,1/20,1 400 50 3 Deutz D2009L03 Diesel 3 in line 1718 Natural Water Electric 1500 Mechanical 15,60 14,80 5,80 NA 2,84 3,79 12 Deutz D2009L04 Diesel 4 in line 2290 Natural Water Electric 1500 Mechanical 20,00 19,10 7,50 NA 3,91 5,21 12 Mecc-Alte ECO 3 2L 4 15,00 86,80 Electronic Stamford BCI 184E 4 22,50 84,20 Electronic 1800 830 1300 785 78 20 66 91 1800 830 1300 785 78 20 66 91 Panels - MCP Analogue n° 7, pag. 79 - ACP n° 9, pag. 80 - MCP Digital n° 13, pag. 81 35 INDUSTRIAL GENERATORS SOUNDPROOF GSW 65d-170d GSW SERIES RENTAL ENERGY II Specially designed for the most demanding power rating in general applications, ideal for rental operators. With a modern design, low noise levels and versatile accessories, this family is easily adaptable to fit any particular specification. FULLY BUNDED BASEFRAME Accessories Engine electronic governor Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Connection kit for communication via Modem / GSM (only for automatic versions) Exceptional water cooled engines selection Lockable door handles Single phase version Rental kit Socket kit Galvanized baseframe Site trailer Road trailer-rigid var Detachable canopy panels Fork lifts easy transportation GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GUARANTEED SOUND POWER LEVEL LWA dB(A) (1) GSW65d GSW80d GSW110d GSW145d (1) GSW170d three phase three phase three phase three phase three phase 50/63 46/58 400 50 3 63/78 59/74 400 50 3 86/108 82/102 400 50 3 113/142 108/135 400 50 3 134/167 127/159 400 50 3 Deutz BF4M2012 G2 Diesel 4 in line 4040 Turbo Water Electric 1500 Mechanical 58 52 8,5 15,9 10,26 13,68 12 Deutz BF4M2012C Diesel 4 in line 4040 Turbo, CAC Water Electric 1500 Mechanical 70 66,1 8,5 17,9 11,74 15,66 12 Deutz BF4M1013EC Diesel 4 in line 4760 Turbo, CAC Water Electric 1500 Mechanical 96,1 91,1 11 19,7 16,67 22,23 12 Deutz BF6M1013E Diesel 6 in line 7150 Turbo Water Electric 1500 Mechanical 123,8 117,8 20 23,1 21,88 29,17 12 Deutz BF6M1013EC Diesel 6 in line 7150 Turbo, CAC Water Electric 1500 Mechanical 145,1 138,1 20 23,1 24,54 32,72 12 Stamford UCI 224E 4 63 88,8 Electronic Stamford UCI 224F 4 80 89,9 Electronic Stamford UCI 274C 4 110 90,3 Electronic Stamford UCI 274E 4 150 91,7 Electronic Stamford UCI 274F 4 175 92,3 Electronic 2710 1180 1535 1300 340 33,14 70 95 2710 1180 1535 1460 340 28,95 70 95 3000 1150 1680 1900 340 20,39 72 97 3400 1250 1680 2180 340 15,54 71 96 3400 1250 1680 2250 340 13,86 71 96 This Generator is normally intended to be used for industrial application only. In this case, its engine would not have to comply with EU 97/68/EC Stage II (EU2007) Directive (no need for subsequent modifications and/or integrations). Panels - MCP Analogue n° 7, pag. 79 - ACP n° 9, pag. 80 - MCP Digital n° 12, pag. 80 37 INDUSTRIAL GENERATORS SOUNDPROOF GSW 195d-220d GSW SERIES THE FULL EQUIP POWER This range of generators includes a complete instrumentation panel, which offers maximum protection and the highest endurance, making them suitable for many high demanding activities, such as rental, telecommunications, UPS systems and industrial applications. FULLY BUNDED BASEFRAME Accessories Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Connection kit for communication via Modem / GSM (only for automatic versions) Large doors for easy maintenance Different avaibility of panels Rental kit Site trailer Road trailer-rigid bar Galvanized skids Socket kit Higher quality components Wide range of accesories GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GUARANTEED SOUND POWER LEVEL LWA dB(A) GSW195d GSW220d three phase three phase 155/194 149/186 400 50 3 176/220 166/208 400 50 3 Deutz BF6M1013FCP G2 Diesel 6 in line 7150 Turbo intercooler Water Electric 1500 Electronic 178,6 161,6 20 27,3 32,9 43,86 24 Deutz BF6M1013FCP G3 Diesel 6 in line 7150 Turbo intercooler Water Electric 1500 Electronic 196,6 178,6 20 27,3 36,84 49,12 24 Stamford UCI 274G 4 194 92,4 Electronic Stamford UCI 274H 4 220 93,3 Electronic 3400 1250 2070 2700 340 10,3 70 95 3400 1250 2070 2700 340 9,2 70 95 Panels - MCP Analogue n° 7, pag. 79 - ACP n° 9, pag. 80 - MCP Digital n° 12, pag. 80 39 INDUSTRIAL GENERATORS SOUNDPROOF GSW 530d-560d GSW SERIES SUITABLE FOR SPECIFIC APPLICATIONS These generators are designed for stand by applications, and fulfill the demand for “silent” power. Sturdy and reliable, like all PRAMAC machines, the “silent” power is guaranteed to fully conform to directive 2000/14/EC, on environmental noise emissions. LEAK PROOF TRAY Accessories Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Residential silencer Innovated air grid design Connection kit for communication via Modem / GSM (only for automatic versions) Socket kit Fully bunded baseframe High performance engine with canbus communication system Terminal board load connection GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MODEL TYPE FUEL NUMBER AND DISPOSITION OF CYLINDERS DISPLACEMENT cc ASPIRATION COOLING SYSTEM STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MODEL TYPE POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GUARANTEED SOUND POWER LEVEL LWA dB(A) GSW530d GSW560d three phase three phase 422/528 367/459 400 50 3 437/546 407/509 400 50 3 Deutz Deutz BF8M1015C G2 BF8M1015CP Diesel Diesel 8V 8V 15900 15900 Turbocharged intercooler Turbocharged intercooler Water Water Electric Electric 1500 1500 Electronic Electronic 449,7 475,9 391,3 433,9 45 45 102 116 72,32 85,62 96,43 114,16 24 24 Mecc-Alte ECO40 3S/4 4 546 94,2 Electronic Mecc-Alte ECO40 3S/4 4 546 94,2 Electronic 4200 1860 2250 4500 636 8,79 73 98 4200 1860 2250 4650 636 7,43 75 100 Panels - ACP n° 8, pag. 79 41 INDUSTRIAL GENERATORS SOUNDPROOF GSW 275V-590V GSW SERIES SILENT POWER FOR PUBLIC AND INDUSTRIAL USES Low noise emissions (conforming to directive 2000/14/EC, related to environmental noise emissions), conformity to gas emission laws and high security (lockable panels, fireproof canopy) make these sets ideal for any public or industrial application, such as hospitals, supermarkets, factories. LEAK PROOF TRAY Accessories Coolant pre-heating system (for automatic start) Automatic fuel transfer pump Load Transfer Switch Panel (LTS) for ACP versions Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions Connection kit for communication via Modem / GSM (only for automatic versions) Lifting structure Fireproof noise attenuation material Socket kit Fully bunded baseframe Rental kit (only for GSW275) Galvanized skids (only for GSW275) Side trailer Exhaust emissions regulations compliant Set of documentation available GSW275V GSW330V GSW415V GSW450V GSW510V GSW560V GSW590V three phase three phase three phase three phase three phase three phase three phase GENERATING SET STAND BY POWER LTP kW/kVA 220/275 264/330 331/414 350/437 406/507 437/546 481/601 PRIME POWER PRP kW/kVA 202/252 252/315 302/378 329/411 369/461 404/505 457/571 VOLTAGE Volt 400 400 400 400 400 400 400 FREQUENCY Hz 50 50 50 50 50 50 50 PHASES 3 3 3 3 3 3 3 ENGINE MODEL Volvo Volvo Volvo Volvo Volvo Volvo Volvo TYPE TAD734GE TAD941GE TAD1241GE TAD1242GE TAD1640GE TAD1641GE TAD1642GE FUEL Diesel Diesel Diesel Diesel Diesel Diesel Diesel NUMBER AND DISPOSITION OF CYLINDERS 6 in line 6 in line 6 in line 6 in line 6 in line 6 in line 6 in line DISPLACEMENT cc 7150 9360 12130 12130 16120 16120 16120 ASPIRATION Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler COOLING SYSTEM Water Water Water Water Water Water Water STARTING SYSTEM Electric Electric Electric Electric Electric Electric Electric SPEED rpm 1500 1500 1500 1500 1500 1500 1500 SPEED GOVERNOR Electronic Electronic Electronic Electronic Electronic Electronic Electronic STAND BY POWER LTP kW 241 320 354 387 432 473 536 PRIME POWER PRP kW 216 290 323 352 393 430 485 LUBE OIL CAPACITY (MAX) L 29 35 35 35 48 48 48 COOLANT CAPACITY (MAX) L 32 41 44 44 93 93 93 FUEL CONSUMPTION at 75% PRP L/h 39,29 48,45 57,1 62,54 68,07 76,02 87,04 FUEL CONSUMPTION at 100% PRP L/h 52,38 64,61 76,14 83,39 90,76 101,36 116,05 ELECTRICAL CIRCUIT Volt 24 24 24 24 24 24 24 ALTERNATOR MODEL Mecc-Alte Mecc-Alte Mecc-Alte Mecc-Alte Mecc-Alte Mecc-Alte Mecc-Alte TYPE ECO38 1L N4 ECO38 2L N4 ECO40 1S/4 ECO40 1S/4 ECO40 3S/4 ECO40 3S/4 ECO40 1L/4 POLES 4 4 4 4 4 4 4 STAND BY 163/27°C rating - LTP kVA 275 330 437 437 546 546 601 EFFICIENCY at 75% load 93,7 94,1 93,8 93,8 94,2 94,2 94,6 VOLTAGE REGULATION SYSTEM Electronic Electronic Electronic Electronic Electronic Electronic Electronic OVERALL DIMENSIONS AND WEIGHT LENGTH mm 3550 3950 3950 3950 4400 4400 4400 WIDTH mm 1360 1460 1460 1460 1560 1560 1560 HEIGHT mm 2016 2095 2095 2095 2250 2250 2250 WEIGHT Kg 2725 3200 3760 3760 4495 4495 4900 FUEL TANK CAPACITY L 460 636 636 636 636 636 636 RUNNING TIME at 75% PRP h 11,2 13,13 11,14 10,17 9,34 8,37 7,31 NOISE PRESSURE LEVEL at 7 mt dB(A) 72 72 72 72 73 74 75 GUARANTEED SOUND POWER LEVEL LWA dB(A) 97 97 97 97 98 99 100 Panels - ACP n° 8, pag. 79 43 CUSTOMISED SOLUTIONS Customised solution is the natural result of the knowledge acquired by PRAMAC group in the power generation field, and of the growth of which has contributed to strengthening the Group’s consolidated knowledge. Today, the division specialises in the production of a wide and versatile range of generators from 6 to 2500 kVA, able to satisfy all applications and requirements. Commercial agreements with some of the most important suppliers in the industry guarantee quality, reliability, and durability for all our products and solutions. After a preliminary study phase, all models are carefully designed to meet the highest technical and safety standards, demanded by the market and the most important of our partners: the customer. The Power Engineering division has the experience and the technical know-how to develop solutions to meet every type of request, no matter how particular or specific. Developing solutions requires capacity analysis, project management, project realisation - following customer requierments and all necessary technical and safety standards. PRAMAC have the capability to provide a complete solution according to each market demand and request. Turnkey installations Our specialised staff are able to study and offer turnkey projects for all proposed machines, and to cooperate with the development of the complete project, depending on the agreed technical specifications and terms of reference. Control Panels All the machines can be equipped with manual, automatic ACP or AMF control panels, as well as parallel panels between two or more generators and parallel with the mains. Other options can be studied by our Technical office. Sound proof canopies and Containers The generators can be fitted with soundproof canopies or certified containers with high quality finishing and appearance, to satisfy all requirements. Soundproof versions can be equipped with internal lighting systems (standard in containers), for easy and safe maintenance. Additional electric sockets are also available to allow use of external tools. Customisation All generators are produced in either a standard or customised configuration, according to the customer’s requirements. Each machine is also designed to meet the installation requirements. Applications Utilities Deregulation and privatisation are on the agendas of all countries. The raising of barriers to the energy market is an excellent opportunity to find alternative sources to the National Power Supply companies. Public and Civil Services Applications for hospitals, highways, public transports, medical centres. Constructions sites Production of energy in construction sites to satisfy the demand of electric power in locations not connected to a main power supply. Industrial field The provision of a constant supply of electric energy, necessary to provide continuity of industrial processes. Communications Guaranteed provision of a continuous supply of power, available during possible interruption, to assure services, data and devices integrity. Agricultural Power supply available for any application. Residential applications Peace of mind during power outages. CUSTOMISED SOLUTIONS CUMMINS-MITSUBISHI GPW SERIES SPECIAL SOLUTIONS The GPW series are special generating solutions, produced to order, that can be adapted to our customer's specific requirements. Detailed specifications of the control panels are given at the end of this chapter (p. 52). GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA NOMINAL VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MANUFACTURER MODEL FUEL NUMBER AND DISPOSITION OF CYLINDERS TOTAL DISPLACEMENT cc AIR INTAKE STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MANUFACTURER MODEL POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH (OPEN SET - SOUNDPROOF) mm WIDTH (OPEN SET - SOUNDPROOF) mm HEIGHT (OPEN SET - SOUNDPROOF) mm WEIGHT (OPEN SET - SOUNDPROOF) Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GPW630 GPW810 GPW940 GPW1030 536/670 507/634 400 50 3Y 699/874 649/811 400 50 3Y 813/1016 750/937 400 50 3Y 911/1139 825/1031 400 50 3Y Cummins Cummins Cummins Cummins VTA28 G5 QSK23G3 QST30G3 QST30G4 Diesel Diesel Diesel Diesel 12 a V 6 in line 12 a V 12 a V 28000 23150 30480 30480 Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Electric Electric Electric Electric 1500 1500 1500 1500 Electronic Electronic Electronic Electronic 590 747 875 951 538 682 786 861 68 103 154 154 132 104 121 139 151 140 161 184 202 24 24 24 24 Mecc-Alte ECO 40 1,5L/4 4 670 94,6 Electronic Mecc-Alte ECO 43 1SN 4 874 95,3 Electronic Mecc-Alte ECO 43 2SN 4 1016 95,7 Electronic Mecc-Alte ECO 43 1LN 4 1201 96 Electronic 3650 - 5575 1500 - 1870 2300 - 2620 6388 - 7227 120 1,2 - / 70 4450 - 6550 2250 - 2400 2300 - 3200 6901 - 9589 120 1,0 - / 70 4300 - 7050 2000 - 2400 2450 - 3500 7952 - 10439 120 0,9 - / 70 4300 - 7050 2000 - 2400 2450 - 3500 8106 - 10772 120 0,8 - / 70 GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA NOMINAL VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MANUFACTURER MODEL FUEL NUMBER AND DISPOSITION OF CYLINDERS TOTAL DISPLACEMENT cc AIR INTAKE STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MANUFACTURER MODEL POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH (OPEN SET - SOUNDPROOF) mm WIDTH (OPEN SET - SOUNDPROOF) mm HEIGHT (OPEN SET - SOUNDPROOF) mm WEIGHT (OPEN SET - SOUNDPROOF) Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GPW1290 GPW1360 GPW1720 GPW1900 GPW2030 1136/1420 1037/1296 400 50 3Y 1136/1420 1086/1358 400 50 3Y 1416/1770 1376/1720 400 50 3Y 1555/1944 1490/1863 400 50 3Y 1814/2268 1626/2033 400 50 3Y Mitsubishi Mitsubishi Mitsubishi Mitsubishi Mitsubishi S12R-PTA S12R-PTA2 S16R-PTA S16R-PTA2 S16R-PTAA2 Diesel Diesel Diesel Diesel Diesel 12 a V 12 a V 16 a V 16 a V 16 a V 49030 49030 65370 65370 65370 Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Electric Electric Electric Electric Electric 1500 1500 1500 1500 1500 Electronic Electronic Electronic Electronic Electronic 1190 1285 1590 1740 1895 1080 1165 1450 1580 1684 180 180 230 230 230 198 213 259 291 305 264 284 346 388 407 24 24 24 24 24 Mecc-Alte ECO 43 2LN 4 1420 96,2 Electronic Mecc-Alte ECO 43 2LN 4 1420 96,2 Electronic Stamford PI7D 4 1770 96,2 Electronic Mecc-Alte ECO 46 2S 4 1944 96,5 Electronic Mecc-Alte ECO46 1L 4 2268 96,8 Electronic 4400 - 7410 2000 - 2400 2300 - 3800 10736 - 12881 120 0,6 - / 70 4400 - 7410 2000 - 2400 2300 - 3800 11234 - 13379 120 0,6 - / 70 5175 - 7980 2000 - 2400 2550 - 3800 12352 - 14667 120 0,5 - / 70 5250 - 7980 2000 - 2400 2550 - 3800 14056 - 17221 120 0,4 - / 70 5950 - 7980 2150 - 2400 2800 - 3800 14247 - 17412 120 0,4 - / 70 47 CUSTOMISED SOLUTIONS MTU GPW SERIES SPECIAL SOLUTIONS GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA NOMINAL VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MANUFACTURER MODEL FUEL NUMBER AND DISPOSITION OF CYLINDERS TOTAL DISPLACEMENT cc AIR INTAKE STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MANUFACTURER MODEL POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH (OPEN SET - SOUNDPROOF) mm WIDTH (OPEN SET - SOUNDPROOF) mm HEIGHT (OPEN SET - SOUNDPROOF) mm WEIGHT (OPEN SET - SOUNDPROOF) Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GPW650 GPW720 GPW830 GPW980 GPW1025 536/670 510/638 400 50 3Y 588/735 560/700 400 50 3Y 699/874 656/820 400 50 3Y 813/1016 739/924 400 50 3Y 899/1123 812/1015 400 50 3Y MTU MTU MTU MTU MTU 12V2000G23 12V2000G63 16V2000G23 16V2000G63 18V2000G63 Diesel Diesel Diesel Diesel Diesel 12 a V 12 a V 16 a V 16 a V 18 a V 23880 23880 31840 31840 35800 Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Electric Electric Electric Electric Electric 1500 1500 1500 1500 1500 Electronic Electronic Electronic Electronic Electronic 598 664 762 856 938 541 601 690 775 848 82 82 110 110 130 174 180 200 220 230 93 102 118 134 150 124 136 157 178 200 24 24 24 24 24 Mecc-Alte ECO 40 1,5L/4 4 670 94,6 Electronic Mecc-Alte ECO 40 2L/4 4 735 94,7 Electronic Mecc-Alte ECO 43 1SN 4 874 95,3 Electronic Mecc-Alte ECO 43 2SN 4 1016 95,7 Electronic Mecc-Alte ECO 43 1LN 4 1201 96 Electronic 3860 - 5575 1580 - 1870 2070 - 2620 5758 - 7356 120 1,3 - / 70 4067 - 5575 1580 - 1870 2070 - 2620 6069 - 7667 120 1,2 - / 70 4398 - 6550 1752 - 1900 2210 - 3200 6942 - 9810 120 1,0 - / 70 4398 - 6550 1752 - 1900 2210 - 3200 7144 - 10012 120 0,9 - / 70 4591 - 7050 1752 - 2000 2451 - 3500 7840 - 10813 120 0,8 - / 70 GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA NOMINAL VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MANUFACTURER MODEL FUEL NUMBER AND DISPOSITION OF CYLINDERS TOTAL DISPLACEMENT cc AIR INTAKE STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MANUFACTURER MODEL POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH (OPEN SET - SOUNDPROOF) mm WIDTH (OPEN SET - SOUNDPROOF) mm HEIGHT (OPEN SET - SOUNDPROOF) mm WEIGHT (OPEN SET - SOUNDPROOF) Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GPW1660 GPW1860 GPW2110 GPW2320 GPW2600 1416/1770 1326/1658 400 50 3Y 1555/1944 1480/1850 400 50 3Y 1814/2268 1689/2111 400 50 3Y 2067/2583 1854/2317 400 50 3Y 2160/2700 2070/2588 400 50 3Y MTU MTU MTU MTU MTU 12V4000G23 12V4000G63 16V4000G23 16V4000G63 20V4000G23 Diesel Diesel Diesel Diesel Diesel 12 a V 12 a V 16 a V 16 a V 20 a V 57200 57200 76300 76300 95400 Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Electric Electric Electric Electric Electric 1500 1500 1500 1500 1500 Electronic Electronic Electronic Electronic Electronic 1535 1710 1915 2135 2390 1380 1535 1748 1915 2170 260 260 290 290 390 335 335 430 430 240 266 304 333 367 320 355 406 445 489 24 24 24 24 24 Stamford PI7D 4 1770 96,2 Electronic Mecc-Alte ECO 46 2S 4 1944 96,5 Electronic Mecc-Alte ECO 46 1L 4 2268 96,8 Electronic Mecc-Alte ECO 46 2L 4 2700 97 Electronic Mecc-Alte ECO 46 2L 4 2700 97 Electronic 4890 - 7550 2000 - 2200 2448 - 3550 12972 - 15117 120 0,5 - / 70 5677 - 8550 2286 - 2500 2790 - 3900 16165 - 18430 120 0,5 - / 70 5762 - 8550 2286 - 2500 2790 - 3900 16649 - 18914 120 0,4 - / 70 5762 - 8550 2286 - 2500 2790 - 3900 16649 - 18914 120 0,4 - / 70 6990 - 11380 2500 - 2500 3350 - 4500 18000 - 22300 120 0,3 - / 70 49 CUSTOMISED SOLUTIONS PERKINS GPW SERIES SPECIAL SOLUTIONS GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA NOMINAL VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MANUFACTURER MODEL FUEL NUMBER AND DISPOSITION OF CYLINDERS TOTAL DISPLACEMENT cc AIR INTAKE STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MANUFACTURER MODEL POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH (OPEN SET - SOUNDPROOF) mm WIDTH (OPEN SET - SOUNDPROOF) mm HEIGHT (OPEN SET - SOUNDPROOF) mm WEIGHT (OPEN SET - SOUNDPROOF) Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GPW655 GPW740 GPW800 GPW975 GPW1020 536/670 511/639 400 50 3Y 588/735 560/700 400 50 3Y 699/874 646/807 400 50 3Y 813/1016 780/975 400 50 3Y 907/1134 825/1031 400 50 3Y Perkins Perkins Perkins Perkins Perkins 2806C-E18 TAG2 4006C-23 TAG2A 4006C-23 TAG3A 4008TAG2A 4008TAG2A Diesel Diesel Diesel Diesel Diesel 6 in line 6 in line 6 in line 8 in line 8 in line 18100 22921 22921 30561 30561 Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Electric Electric Electric Electric Electric 1500 1500 1500 1500 1500 Electronic Electronic Electronic Electronic Electronic 599 685 760 947 947 542 620 679 861 861 55,5 113 113 166 166 61 105 105 162 162 96 109 124 158 167 128 145 166 211 222 24 24 24 24 24 Mecc-Alte ECO 40 1,5L/4 4 670 94,6 Electronic Mecc-Alte ECO 40 2L/4 4 735 94,7 Electronic Mecc-Alte ECO 43 1SN 4 874 95,3 Electronic Mecc-Alte ECO 43 2SN 4 1016 95,7 Electronic Mecc-Alte ECO 43 1LN 4 1201 96 Electronic 3391 - 5075 1536 - 1870 2050 - 2620 4860 - 6410 120 1,3 - / 70 3960 - 6550 1706 - 2000 2131 - 3450 6193 - 8456 120 1,1 - / 70 3960 - 6550 1706 - 2000 2131 - 3450 6203 - 8456 120 1,0 - / 70 4830 - 7260 1868 - 2100 2494 - 3500 8004 - 9873 120 0,8 - / 70 4830 - 7160 1868 - 2100 2494 - 3500 8166 - 10105 120 0,7 - / 70 GENERATING SET STAND BY POWER LTP kW/kVA PRIME POWER PRP kW/kVA NOMINAL VOLTAGE Volt FREQUENCY Hz PHASES ENGINE MANUFACTURER MODEL FUEL NUMBER AND DISPOSITION OF CYLINDERS TOTAL DISPLACEMENT cc AIR INTAKE STARTING SYSTEM SPEED rpm SPEED GOVERNOR STAND BY POWER LTP kW PRIME POWER PRP kW LUBE OIL CAPACITY (MAX) L COOLANT CAPACITY (MAX) L FUEL CONSUMPTION at 75% PRP L/h FUEL CONSUMPTION at 100% PRP L/h ELECTRICAL CIRCUIT Volt ALTERNATOR MANUFACTURER MODEL POLES STAND BY 163/27°C rating - LTP kVA EFFICIENCY at 75% load VOLTAGE REGULATION SYSTEM OVERALL DIMENSIONS AND WEIGHT LENGTH (OPEN SET - SOUNDPROOF) mm WIDTH (OPEN SET - SOUNDPROOF) mm HEIGHT (OPEN SET - SOUNDPROOF) mm WEIGHT (OPEN SET - SOUNDPROOF) Kg FUEL TANK CAPACITY L RUNNING TIME at 75% PRP h NOISE PRESSURE LEVEL at 7 mt dB(A) GPW1250 GPW1320 GPW1500 GPW1700 GPW1850 1108/1385 1002/1253 400 50 3Y 1136/1420 1086/1358 400 50 3Y 1319/1649 1199/1499 400 50 3Y 1416/1770 1366/1707 400 50 3Y 1555/1944 1482/1852 400 50 3Y Perkins Perkins Perkins Perkins Perkins 4012TWG2 4012-46TWG3A 4012TAG2A 4012-46 TAG3A 4016TAG1A Diesel Diesel Diesel Diesel Diesel 12 a V 12 a V 12 a V 12 a V 16 a V 45842 45842 45842 45842 61123 Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Electric Electric Electric Electric Electric 1500 1500 1500 1500 1500 Electronic Electronic Electronic Electronic Electronic 1154 1263 1380 1563 1690 1044 1149 1254 1421 1537 178 178 178 178 237 210 240 235 210 316 191 201 225 264 281 255 268 300 352 375 24 24 24 24 24 Mecc-Alte ECO 43 2LN 4 1420 96,2 Electronic Mecc-Alte ECO 43 2LN 4 1420 96,2 Electronic Stamford PI7C 4 1660 95,7 Electronic Stamford PI7D 4 1770 96,2 Electronic Mecc-Alte ECO 46 2S 4 1944 96,5 Electronic 4852 - 7410 1868 - 2100 2686 - 3700 10284 - 12150 120 0,6 - / 70 4962 - 7410 2265 - 2500 3046 - 4050 11019 - 13260 120 0,6 - / 70 4962 - 7410 2265 - 2500 3046 - 4050 11317 - 13558 120 0,5 - / 70 5620 - 7980 2150 - 2400 2720 - 3800 14136 - 16450 120 0,5 - / 70 5620 - 8970 2775 - 3000 3516 - 3820 14588 - 17750 120 0,4 - / 70 51 CUSTOMISED SOLUTIONS LTS COMMANDS 1) Motorized change over switchgear integrated into the same device. 2) n° 3 positions selector switch, placed on the front of the panel, which allows selecting manually the following positions: • AUTO: operating mode based on the automatic logic control. • MAINS: Mains power supply forcement. • GENSET: Genset power supply forcement. 3) Manual pulley, placed on the own change over contactors, for emergency load transfer. CONNECTIONS 1) Plinth row for connection from MCB (main circuit breaker) to LTS panel. 2) Terminals board for power cables connection (GENSET - MAINS - LOAD). PROTECTION 1) Mechanically and electrically interlocked. 2) n° 2 visual LED's to show the contactors position: MAINS - GENSET. 3) Mechanical degree of protection: IP40 (external) and IP20 (internal). ACP DIGITAL INSTRUMENTATION Genereting set voltage (3 phases) Mains voltage Generating set frequency Generating set current (3 phases) Battery voltage Active power (kW) Reactive power (kVAr) Apparent power (kVA) Power factor (cosϕ) Start-counter Active energy counter (kWh) no fiscal Hours-counter Oil pressure (optional) Engine coolant temperature (optional) ALARMS SHOWN ON DISPLAY Generator overload (derived from external contact of MCB) Running under conditions not reached Generator under voltage Generator over voltage Generator under frequency Generator over frequency Maximum power PROTECTIONS WITH SHUTDOWN AUXILIARY SERVICES Power reverse High engine coolant temperature Automatic battery charger Closing of Mains contactor Engine coolant preheating system power supply Low oil pressure Overspeed (derived from generator frequency) or genset contactor failed (single phase) Stop failure Engine over-crank Acoustic alarm No fuel Programmable periodic test Emergency stop Genset report COMMANDS AND OTHERS Key operated mode selector switch Engine start push button Engine stop push button Emergency stop push button Acoustic alarm silencing push button UP/DOWN push button for display selection Accessories EFO: extended capacity on base fuel tank DPP: differential protection (available only with IV poles circuit breaker) AFP: automatic refueling system RES: residential silencer (only for open set version) PHS: coolant preheating system (necessary for starting under ambient conditions < +10ºC) TIF: IV poles circuit breaker instead of III poles PROTECTIONS WITHOUT SHUTDOWN Battery failure (maximum/minimum voltage) Pre-alarm for low oil pressure (optional) Pre-alarm for high engine coolant temperature (optional) Generator overload (derived from external contact of MCB). ITALY AEM di Torino AEM di Milano ENEL Compartimento di Roma ENEL Compartimento di Venezia ENEL Compartimento di Firenze ENEL Direzione Piemonte - V.D’Aosta ENEL Compartimento di Cagliari Teatro Regio di Torino Teatro di Vicenza Palazzo Borsa di Milano Istituto Bocconi di Milano Centro Direzionale Pirelli di Milano Parco Gardaland (Verona) Stadio Olimpico di Torino Stadio Friuli di Udine Stadio Ferraris di Genova Stadio S. Paolo di Napoli Autostrada Palermo Messina Palazzo della Provincia di Firenze Tribunale di Genova IKEA di Ancona LIDL di Pontedera (Pisa) Università di Udine ERG Raffinerie di Siracusa Aeroporto di Comiso (Ragusa) Aeroporto di Ciampino (Roma) Ospedale Careggi di Firenze Azienda Ospedaliero-Universitaria Pisana Università Campus Biomedico di Roma Ospedale “S. Andrea” di Roma Ospedale “Spallanzani” di Roma Policlinico di Bari Fondazione CNAO di Pavia Ospedale di Catania Antenna SKYLOGIC (Torino) FRANCE Hôpital de La Châtre Cafés Richard à Gennevilliers Magasins Leader Price (Guadeloupe) Station d’épuration d’Auray Parkings de Bordeaux Station de pompage de Pierrefite Exaltis à La Défense Buref à La Défense Centre de rétention aéroport de Toulouse Centre d’appel TRANSCOM à Roanne Station d’épuration Canet en Roussillon Usine PHOTOWATT à Bourgoin Jallieu Others AMENA (SPAIN) MOBITEL (VIETNAM) ERA (POLAND) BALTON (SUDAN) GRAMEEN PHONE (BANGLADESH) SWITCH (SUDAN) HOTEL RIU (BAHAMAS) WAL MART (MEXICO) GHANA TELECOM (GHANA) STATOIL (NORWAY) DHL LOGISTICS (Normanton UK) CUSTOMISED SOLUTIONS GCW UNITS The GCW units are customised generators specially developed and produced against specific requests of each customer. The following project was developed for the STATOIL company in Norway. Company Brief Statoil is an integrated oil and gas company with substantial international activities. It was created in 1972 when the Norwegian Parliament decided to establish a state crude oil company, the STATOIL. Its main activity consisted of the exploration, production, distribution, refinery and sales of crude oil and its derivates, operating alone or together with other companies. Case Brief Customized Generating Set for operating at very low temperatures. The machine was placed inside a 25’ container, equipped with motorized louvers and electric fans, to extract residual hot air generated by the engine, as a self-standing heating system. The engine is equipped with water and oil pre-heaters, and an electric fan radiator installed in the external container space. The fuel is pre-heated and supplied from an external tank, through insulated pipes, making the installation suitable to work in -20° C environments. The automatic mains failure control panel is equipped with a SIEMENS motorized circuit breaker. Since the operation motor switch was not available for 690Vac, a UPS was intentionally installed. 2896 265 2160 600 100 545 1055 375 2105 415 7620 5300 2896 GRIGIA MOTORIZZ SU ASPIRAZIONE ZOCCOLO H=110mm SOTTO EL.RADIATORE 119 A CURA DI PRAMAC 411 350 350 300 300 DATA SHEET MAIN CHARACTERISTICS MODEL NAME COUNTRY ENGINE ALTERNATOR POWER PRP kVA/kW POWER LTP kVA/kW VOLTAGE V FREQUENCY Hz NOISE PRESSURE LEVEL at 7 mt dB(A) TANK CAPACITY L LENGTH mm 325 275 300 GCW1560-50S (TORNADO 1500) NORWAY MTU 12V4000G61 STAMFORD HCI7F 1557/1245 1630/1304 690 50 85 External tank 7620 55 PORTABLE GENSET & POWER EQUIPMENT ES SERIES LONG RUN ENERGY A class of petrol generators designed specifically for intensive operations where performance power is demanded by professional users over an extended period of time. UP TO 12 HOURS AUTONOMY Equipment OPTIONAL Hourmeter (except ES5000 single phase, ES8000 single phase) Transportation kit Cover STANDARD Thermal protection Oil guard system Transportation kit Cover Sockets Fuel tank ES3000 ES4000 ES500 ES5000 ES8000 ES8000 single phase petrol single phase petrol three phase petrol single phase petrol three phase petrol single phase petrol THREE PHASE (POWER LTP) kW/kVA (POWER COP) kVA SINGLE PHASE (POWER LTP) kW/kVA 2,59/2,88 (POWER COP) kVA 2,45 POWER SPEC. VOLTAGE Volt 230 FREQUENCY Hz 50 POWER FACTOR cosϕ 0,9 ENGINE MODEL Honda TYPE GX160 DISPLACEMENT cc 163 CYLINDER 1 inclination angle POWER kW 3,6 ASPIRATION Natural COOLING SYSTEM Air STARTING SYSTEM Recoil CONSUMPTION FUEL CONSUMPTION g/kWh 313 FUEL CONSUMPTION at 75% of load L/h 0,9 FUEL TANK CAPACITY L 11 RUNNING TIME at 75% of load h 11,8 NOISE EMISSION GUARANTEED SOUND POWER LEVEL LWA dB(A) 96 NOISE PRESSURE LEVEL at 7 mt dB(A) 70 DIMENSIONS AND WEIGHT LENGTH mm 623 WIDTH mm 409 HEIGHT mm 500 WEIGHT (DRY) Kg 41 SOCKET TYPE 2 SCHUKO ALTERNATOR AND SOCKET PROTECTION ELECTRIC PROTECTION SOCKET PROTECTION COP LTP IP23 IP 54 5,04/6,30 5,36 6,64/8,30 7,00 3,05/3,39 2,88 3,74/4,16 3,14 4,60/5,11 4,20 4,93/5,48 4,11 6,43/7,15 6,00 230 50 0,9 400/230 50 0,8/0,9 230 50 0,9 400/230 50 0,8/0,9 230 50 0,9 Honda GX200 196 1 inclination angle 4,3 Natural Air Recoil Honda GX270 270 inclination angle 6,3 Natural Air Recoil Honda GX270 270 1 inclination angle 6,3 Natural Air Recoil Honda GX390 389 1 inclination angle 8,3 Natural Air Recoil Honda GX390 389 1 inclination angle 8,3 Natural Air Recoil 313 1,1 11 9,9 313 1,6 11 6,7 313 1,6 11 6,7 313 2,1 11 5,1 313 2,2 11 5,1 95 69 97 71 97 71 97 72 97 72 623 409 500 43 729 500 536 75 729 500 536 61 729 500 536 81 729 500 536 73 2 SCHUKO SCHUKO 400V 16A SCHUKO 230V 16A SCHUKO 400V 16A SCHUKO 230V 32A IP23 IP 54 IP23 IP 44 IP23 IP 44 IP23 IP 44 IP23 IP 44 Continuous Power Maximum Power 57 PORTABLE GENSET & POWER EQUIPMENT S SERIES THE COMPLETE PACKAGE All the features of a top class generator: a powerful and economical engine, a strong and modern design and a long-run easy filling fuel tank. LWA 96 dB(A) Equipment STANDARD Magneto Thermal protection (except S3200, S5000 and S8000 single phase with thermal protection) Oil guard system Battery charger 12V-10A (except S3200, S12000) OPTIONAL Differential Protection (except S3200)* Insulation Monitoring* Automatic Voltage Regulator (AVR) (S5000, S8000 three phase only) Automatic Mains Failure (AMF) (except S3200) Remote Control (RSS) (except S3200) Transportation kit Lifting kit/Hook (except S3200, S12000) * Includes Voltmeter, Hourmeter (except S3200) Automatic mains failure Remote start stop Lifting kit Manual transfer switch S3200 S5000 S5000 S8000 S8000 S12000 S12000 single phase petrol three phase petrol single phase petrol three phase petrol single phase petrol three phase petrol single phase petrol THREE PHASE (POWER LTP) kW/kVA 5,04/6,30 6,64/8,30 (POWER COP) kVA 5,36 7,00 SINGLE PHASE (POWER LTP) kW/kVA 2,54/2,82 3,74/4,16 4,79/5,32 4,93/5,48 6,43/7,15 (POWER COP) kVA 2,40 3,14 4,10 4,11 6,00 POWER SPEC. VOLTAGE Volt 230 400/230 230 400/230 230 FREQUENCY Hz 50 50 50 50 50 POWER FACTOR cosϕ 0,9 0,8/0,9 0,9 0,8/0,9 0,9 ENGINE MODEL Honda Honda Honda Honda Honda TYPE GX160 GX270 GX270 GX390 GX390 DISPLACEMENT cc 163 270 270 389 389 CYLINDER 1 inclination angle 1 inclination angle 1 inclination angle 1 inclination angle 1 inclination angle POWER kW 3,6 6,3 6,3 8,3 8,3 ASPIRATION Natural Natural Natural Natural Natural COOLING SYSTEM Air Air Air Air Air STARTING SYSTEM Recoil Electric/Recoil Electric/Recoil Electric/Recoil Electric/Recoil CONSUMPTION FUEL CONSUMPTION g/kWh 313 313 313 313 313 FUEL CONSUMPTION at 75% of load L/h 0,9 1,6 1,6 2,1 2,2 FUEL TANK CAPACITY L 11 18 18 18 18 RUNNING TIME at 75% of load h 11,8 11,0 11,0 8,4 8,4 NOISE EMISSION GUARANTEED SOUND POWER LEVEL LWA dB(A) 96 97 97 97 97 NOISE PRESSURE LEVEL at 7 mt dB(A) 70 71 71 72 72 DIMENSIONS AND WEIGHT LENGTH mm 623 842 842 842 842 WIDTH mm 409 523 523 523 523 HEIGHT mm 500 557 557 557 557 WEIGHT (DRY)** Kg 42 88 76 99 96 SOCKET TYPE 2 SCHUKO SCHUKO SCHUKO SCHUKO SCHUKO 400V 16A 230V 32A 400V 16A 230V 32A ALTERNATOR AND SOCKET PROTECTION ELECTRIC PROTECTION SOCKET PROTECTION COP LTP ** IP23 IP 54 IP23 IP 44 IP23 IP 44 IP23 IP 44 IP23 IP 44 11,14/13,92 11,83 8,27/9,19 6,94 10,69/11,88 10,00 400/230 50 0,8/0,9 230 50 0,9 Honda GX620 614 2-V 13,5 Natural Air Electric Honda GX620 614 2-V 13,5 Natural Air Electric 313 3,5 24 6,9 313 3,5 24 6,9 96 70 96 70 960 641 667 165 960 641 667 162 SCHUKO 2 x 230V 16A 400V 16A SCHUKO 230V 16A 230V 32A IP23 IP 44 IP23 IP 44 Continuous Power Maximum Power On electric version +3/8 Kg to add 59 PORTABLE GENSET & POWER EQUIPMENT S SERIES THE YELDING PACKAGE Showing the excellence of PRAMAC's professional equipment, this range offers a robust package with a modern and economical diesel engine. Equipment OPTIONAL Differential Protection (S9000 three phase only) Insulation Monitoring Voltmeter (S9000 only) Hourmeter (S6000 only) Automatic Mains Failure (AMF) Remote Control (RSS) Transportation kit STANDARD Magneto Thermal protection (S9000 single phase thermal protection) Oil Pressure Indicator (S9000 only) Differential Protection (except S9000) Voltmeter (except S9000) Battery charger (except S9000) Manual transfer switch Remote start stop Automatic mains failure Transportation kit with folding handles THREE PHASE (POWER LTP) kW/kVA (POWER COP) kVA SINGLE PHASE (POWER LTP) kW/kVA (POWER COP) kVA POWER SPEC. VOLTAGE Volt FREQUENCY Hz POWER FACTOR cosϕ ENGINE MODEL TYPE DISPLACEMENT cc CYLINDER POWER kW ASPIRATION COOLING SYSTEM STARTING SYSTEM CONSUMPTION FUEL CONSUMPTION g/kWh FUEL CONSUMPTION at 75% of load L/h FUEL TANK CAPACITY L RUNNING TIME at 75% of load h NOISE EMISSION GUARANTEED SOUND POWER LEVEL LWA dB(A) NOISE PRESSURE LEVEL at 7 mt dB(A) DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT (DRY) Kg SOCKET TYPE ALTERNATOR AND SOCKET PROTECTION ELECTRIC PROTECTION SOCKET PROTECTION • COP LTP S4500 S6000 S6500 S9000 S9000 single phase diesel three phase diesel single phase diesel three phase diesel single phase diesel 5,49/6,86 5,62 8,21/10,26 8,83 3,65/4,05 3,45 4,07/4,53 3,30 5,31/5,90 4,84 6,10/6,77 5,18 7,90/8,78 7,55 230 50 0,9 400/230 50 0,8/0,9 230 50 0,9 400/230 50 0,8/0,9 230 50 0,9 Yanmar L70 296 1 Vertical 4,8 Natural Air Electric Yanmar L100 406 1 Vertical 6,9 Natural Air Electric Yanmar L100 406 1 Vertical 6,9 Natural Air Electric Ruggerini MD150 654 2 In line 10 Natural Air Electric Ruggerini MD150 654 2 In line 10 Natural Air Electric 272 1,0 3,5 3,5 272 1,4 5,5 4,0 272 1,4 5,5 4,0 260 2,0 24 12,0 260 2,0 24 12,0 • • • • • • • • • • 810 450 500 81 830 490 570 108 830 490 570 99 970 600 690 148 970 600 690 141 SCHUKO 230V 16A 230V 32A 2 x SCHUKO 230V 16A 400V 16A SCHUKO 230V 16A 230V 32A SCHUKO 400V 16A SCHUKO 230V 32A IP23 IP 44 IP23 IP 44 IP21 IP 44 IP23 IP 44 IP23 IP 44 For fixed installation only Continuous Power Maximum Power 61 PORTABLE GENSET & POWER EQUIPMENT SP SERIES THE COMPLETE PROTECTION A premium range with insulation monitoring and Automatic Voltage Regulator as standard. All panels and alternators featuring IP54 protection. IP 54 Equipment OPTIONAL Transportation kit Lifting kit/Hook (SP8000 only) STANDARD Magneto Thermal protection Oil guard system Insulation Monitoring Voltmeter (SP12000 only) Hourmeter Automatic Voltage Regulator (AVR) Transportation kit Lifting kit IP54 isometer panel Large fuel tank THREE PHASE (POWER LTP) kW/kVA (POWER COP) kVA SINGLE PHASE (POWER LTP) kW/kVA (POWER COP) kVA POWER SPEC. VOLTAGE Volt FREQUENCY Hz POWER FACTOR cosϕ ENGINE MODEL TYPE DISPLACEMENT cc CYLINDER POWER kW ASPIRATION COOLING SYSTEM STARTING SYSTEM CONSUMPTION FUEL CONSUMPTION g/kWh FUEL CONSUMPTION at 75% of load L/h FUEL TANK CAPACITY L RUNNING TIME at 75% of load h NOISE EMISSION GUARANTEED SOUND POWER LEVEL LWA dB(A) NOISE PRESSURE LEVEL at 7 mt dB(A) DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT (DRY) Kg SOCKET TYPE ALTERNATOR AND SOCKET PROTECTION ELECTRIC PROTECTION SOCKET PROTECTION ** COP LTP SP8000 SP12000 three phase petrol three phase petrol 7,06/8,82 6,75 11,07/13,84 11,76 5,24/5,82 3,96 7,31/9,13 7,76 400/230 50 0,8/0,9 400/230 50 0,8/0,9 Honda GX390 389 1 inclination angle 8,3 Natural Air Electric/Recoil Honda GX620 614 2-V 13,5 Natural Air Electric 313 1,9 18 9,3 313 3,5 24 6,9 97 72 96 70 842 523 557 113 960 641 667 170 230V 16A 400V 16A 3 x SCHUKO 400V 16A 400V 32A IP54 IP54 IP54 IP54 On electric version +3/8 Kg to add Continuous Power Maximum Power 63 PORTABLE GENSET & POWER EQUIPMENT P SERIES THE SILENT POWER I SUPER SILENCED The ideal generator for use in residential areas or outside normal working hours. These generators are equipped with first quality components and complete instrumentation. Equipment OPTIONAL Differential Protection Insulation Monitoring Automatic Mains Failure (AMF) Remote Control (RSS) Transportation kit STANDARD Magneto Thermal protection Voltmeter Lifting kit/Hook (except P4500) Oil guard (on P6000S) Overtemperature protection (on P6000s) Oil pressure indicator (on P9000) Automatic mains failure Manual transfer switch Transport kit Complete panel with differential THREE PHASE (POWER LTP) kW/kVA (POWER COP) kVA SINGLE PHASE (POWER LTP) kW/kVA (POWER COP) kVA POWER SPEC. VOLTAGE Volt FREQUENCY Hz POWER FACTOR cosϕ ENGINE MODEL TYPE DISPLACEMENT cc CYLINDER POWER kW ASPIRATION COOLING SYSTEM STARTING SYSTEM CONSUMPTION FUEL CONSUMPTION g/kWh FUEL CONSUMPTION at 75% of load L/h FUEL TANK CAPACITY L RUNNING TIME at 75% of load h NOISE EMISSION GUARANTEED SOUND POWER LEVEL LWA dB(A) NOISE PRESSURE LEVEL at 7 mt dB(A) DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT (DRY)** Kg SOCKET TYPE ALTERNATOR AND SOCKET PROTECTION ELECTRIC PROTECTION SOCKET PROTECTION ** COP LTP P4500 P6000 P6000 P6000s P6000s P9000 P9000 single phase diesel three phase diesel single phase diesel three phase diesel single phase diesel three phase diesel single phase diesel 5,49/6,86 5,62 5,49/6,86 5,62 8,21/10,26 8,83 3,65/4,05 3,45 4,07/4,53 3,30 5,31/5,90 4,84 4,07/4,53 3,30 5,35/5,94 4,87 6,10/6,77 5,18 7,90/8,78 7,55 230 50 0,9 400/230 50 0,8/0,9 230 50 0,9 400/230 50 0,8/0,9 230 50 0,9 400/230 50 0,8/0,9 230 50 0,9 Yanmar L70 296 1 Vertical 4,8 Natural Air Electric/Recoil Yanmar L100 406 1 Vertical 6,9 Natural Air Electric Yanmar L100 406 1 Vertical 6,9 Natural Air Electric Yanmar L100 406 1 Vertical 6,9 Natural Air Electric Yanmar L100 406 1 Vertical 6,9 Natural Air Electric Ruggerini MD150 654 2 In line 10 Natural Air Electric Ruggerini MD150 654 2 In line 10 Natural Air Electric 272 1,0 18 18,2 272 1,4 24 17,5 272 1,4 24 17,5 272 1,4 19 13,8 272 1,4 19 13,8 260 2,0 24 12,0 260 2,0 24 12,0 96 71 97 72 97 72 84 58 84 58 97 72 97 72 800 520 660 103 930 555 800 153 930 555 800 149 970 580 927 203 970 580 927 203 930 555 800 193 930 555 800 190 SCHUKO 230V 16A 230V 32A SCHUKO 2 x 230V 16A 400V 16A SCHUKO 230V 16A 230V 32A SCHUKO 230V 16A 400V 16A SCHUKO 230V 16A 230V 32A SCHUKO 2 x 230V 16A 400V 16A SCHUKO 230V 16A 230V 32A IP23 IP 44 IP23 IP 44 IP23 IP 44 IP23 IP 44 IP23 IP 44 IP23 IP 44 IP23 IP 44 On electric version +3/8 Kg to add Continuous Power Maximum Power 65 PORTABLE GENSET & POWER EQUIPMENT P SERIES THE SILENT POWER II Low noise level, AMF or RSS features and powerful, reliable diesel engines. These generators are ideal for domestic backup power supply or professional use in residential areas. Equipment OPTIONAL Differential Protection (except P11000) Insulation Monitoring (petrol versions only) Preheater (diesel version only) Automatic Mains Failure (AMF) Remote Control (RSS) Transportation kit STANDARD Magneto Thermal protection Oil guard system (except P12000 diesel) Oil Pressure Indicator (except P12000 petrol) Insulation Monitoring (diesel version only) Overtemperature Protection (P11000 only) Voltmeter Hourmeter (diesel version only) Lifting kit/Hook Transport kit Automatic mains failure Remote start stop Isometer panel THREE PHASE (POWER LTP) kW/kVA (POWER COP) kVA SINGLE PHASE (POWER LTP) kW/kVA (POWER COP) kVA POWER SPEC. VOLTAGE Volt FREQUENCY Hz POWER FACTOR cosϕ ENGINE MODEL TYPE DISPLACEMENT cc CYLINDER POWER kW ASPIRATION COOLING SYSTEM STARTING SYSTEM CONSUMPTION FUEL CONSUMPTION g/kWh FUEL CONSUMPTION at 75% of load L/h FUEL TANK CAPACITY L RUNNING TIME at 75% of load h NOISE EMISSION GUARANTEED SOUND POWER LEVEL LWA dB(A) NOISE PRESSURE LEVEL at 7 mt dB(A) DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT (DRY) Kg SOCKET TYPE ALTERNATOR AND SOCKET PROTECTION ELECTRIC PROTECTION SOCKET PROTECTION COP LTP P11000 P11000 P12000 P12000 P12000 three phase diesel single phase diesel three phase diesel three phase petrol single phase petrol 12,63/15,79 11,00 11,14/13,92 11,83 8,48/10,60 10,00 5,25/6,56 6,00 9,54/10,60 10,00 9,38/10,42 6,45 8,27/9,19 6,94 10,69/11,88 10,00 400/230 50 0,8/0,9 230 50 0,9 400/230 50 0,8/0,9 400/230 50 0,8/0,9 230 50 0,9 Yanmar 3TNV70 854 3 In line 12 Natural Water Electric Yanmar 3TNV70 854 3 In line 12 Natural Water Electric Hatz 2 G 40 997 2 In line 15,4 Natural Air Electric Honda GX620 614 2-V 13,5 Natural Air Electric Honda GX620 614 2-V 13,5 Natural Air Electric 306 3,0 24 7,0 306 3,0 24 9,0 235 2,3 17 7,5 313 3,5 24 6,9 313 3,5 24 6,9 96 70 96 70 97 72 96 70 96 70 1451 650 975 325 1451 650 975 325 1270 830 920 275 930 555 800 176 930 555 800 166 230V 16A 230V 32A 400V 16A 2 x 230V 16A 230V 32A 230V 16A 230V 32A 400V 16A SCHUKO 2 x 230V 16A 400V 16A SCHUKO 230V 16A 230V 32A IP23 IP 44 IP23 IP 44 IP23 IP 44 IP23 IP 44 IP23 IP 44 Continuous Power Maximum Power 67 PORTABLE GENSET & POWER EQUIPMENT W SERIES MECHANIC WELDING REGULATION Welders from 170 to 220A with mechanical regulation of the welding current. Reliability, sturdiness. Soundproof and open versions depending on each particular need. Equipment OPTIONAL Differential Protection (W180, W230 only) Transportation kit Small wheel transportation kit (WP180, WP230 only) Welding kit STANDARD Magneto thermal protection Oil guard system (petrol version only) Voltmeter (WP180, WP230 only) Double positive welding socket (with additional resistance) Serie W panel Compactness Serie WP panel Lifting eye WELDING GENERATOR WELDING CURRENT A MIN/MAX WELDING VOLTAGE V WELDING SERVICE at 60% A MAX DIAMETER OF ELECTRODE RUTILE mm BASIC mm CELLULOSE mm THREE PHASE POWER (LTP) kW/kVA POWER (COP) kVA SINGLE PHASE POWER (LTP) kW/kVA POWER (COP) kVA POWER SPEC. VOLTAGE VOLT FREQUENCY Hz POWER FACTOR cosϕ ENGINE MODEL TYPE DISPLACEMENT cc CYLINDER POWER kW ASPIRATION COOLING SYSTEM STARTING SYSTEM CONSUMPTION CONSUMPTION g/kWh CONSUMPTION at 75% of load L/h TANK CAPACITY L RUNNING TIME at 75% of load h NOISE EMISSION NOISE LEVEL LWA dB(A) ACOUSTIC PRESSURE at 7 m dB(A) DIMENSIONS AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT (DRY)** Kg SOCKET TYPE ALTERNATOR AND SOCKET PROTECTION ELECTRIC PROTECTION SOCKET PROTECTION ** • COP LTP W170 W210 W180 W230 WP180 WP230 three phase petrol three phase petrol three phase diesel three phase diesel three phase diesel three phase diesel 30-170 21,2/26,8 130 30-200 21,2/28 170 30-180 21,2/27,2 140 30-220 21,2/28,8 180 30-180 21,2/27,2 140 30-220 21,2/28,8 180 4 3,25 3,25 5 4 5 4 4 4 5 4 5 4 4 4 5 4 5 4,00/5,00 4,50 5,10/6,38 6,00 4,20/5,25 5,00 5,73/7,16 6,50 4,20/5,25 5,00 5,73/7,16 6,50 4,00/4,44 4,00 4,00/4,44 4,00 4,00/4,44 4,00 4,00/4,44 4,00 4,00/4,44 4,00 4,00/4,44 4,00 400/230 50 0,8/0,9 400/230 50 0,8/0,9 400/230 50 0,8/0,9 400/230 50 0,8/0,9 400/230 50 0,8/0,9 400/230 50 0,8/0,9 Honda GX270 270 1 Vertical 6,3 Natural Air Recoil Honda GX390 389 1 Vertical 8,3 Natural Air Electric\Recoil Yanmar L100 406 1 Vertical 6,9 Natural Air Electric Ruggerini MD150 654 2 in line 10 Natural Air Electric Yanmar L100 406 1 Vertical 6,9 Natural Air Electric Ruggerini MD150 654 2 in line 10 Natural Air Electric 313 1,6 6 3,7 313 2,1 6,5 3 272 1,4 5,5 3,8 260 2,05 18 8,8 272 1,4 24 16,9 260 2,1 24 11,7 97 72 97 72 • • • • 97 72 97 72 810 610 600 108 810 610 600 114 810 610 600 143 970 600 690 176 930 555 800 180 930 555 800 193 230V 16A 400V 16A 230V 16A 400V 16A 230V 16A 400V 16A 230V 16A 400V 16A 3 x 230V 16A 400V 16A 3 x 230V 16A 400V 16A IP23 IP44 IP23 IP44 IP23 IP44 IP23 IP44 IP23 IP44 IP23 IP44 On electric version +3/8 Kg to add For fixed installation only Continuous Power Maximum Power 69 PORTABLE GENSET & POWER EQUIPMENT PW SERIES DIRECT AND GEARBOX TRANSMISSION Easily transportable and ready to use; this is the ideal machine for the myriad of professional and residential uses. PW1500 PW150 PW3000 PW240 PW3000 petrol petrol petrol petrol diesel 200/2900 15 1450 240/3500 12,5 3400 200/2900 15 1450 Honda GX340 337 1 Inclined 8 Natural Air Recoil Honda GX390 389 1 Inclined 9,6 Natural Air Electric/Recoil Yanmar L100 435 1 Vertical 7 Natural Air Electric 313 2 6,5 3,2 313 2,5 6,5 2,7 272 1,5 5,5 3,6 110 85 103 78 108 83 1040 590 790 72 951 765 655 64 1040 590 790 117 PUMP MAX PRESSURE bar/psi 110/1600 150/2200 FLOW L/min 11,4 11,4 REVOLUTIONS rpm 1750 3400 ENGINE MODEL Honda Honda TYPE GX160 GX160 DISPLACEMENT cc 163 163 CYLINDER 1 Inclined 1 Inclined POWER kW 4 4 ASPIRATION Natural Natural COOLING SYSTEM Air Air STARTING SYSTEM Recoil Recoil CONSUMPTION CONSUMPTION g/kWh 313 313 CONSUMPTION at 75% of load L/h 1 1 TANK CAPACITY L 3,6 3,6 RUNNING TIME at 75% of load h 3,5 3,6 NOISE EMISSION NOISE LEVEL LWA dB(A) 107 106 ACOUSTIC PRESSURE at 7 m dB(A) 82 81 DIMENSION AND WEIGHT LENGTH mm 700 630 WIDTH mm 490 580 HEIGHT mm 890 540 WEIGHT (DRY)** Kg 44 32 STANDARD EQUIPMENT, OPTIONS AND ACCESSORIES (x: Standard, o: Optional) 2:1 GEAR BOX x DIRECT DRIVE x DOUBLE LANCE LANCE x x CHEMICAL INJECTION x x PRESSURE HOSE x x SUCTION HOSE WITH STRAINER INLINE FILTER x x OIL GUARD SYSTEM x x TRANSPORTATION KIT x x ** On electric version +3/8 Kg to add x x x x x x x x x x x x x x x x x x x x x x ZG SERIES ENERGY FOR AGRICULTURE These generators provide an economic way to supply electricity to any part of your agricultural land. Using the pto shaft of a tractor, the ZG class generator can produce high quality power for any agricultural use. ZG 100/3 ZG 150/3 THREE PHASE (POWER COP) kW/kVA 6,40/8,00 7,68/9,60 SINGLE PHASE (POWER COP) kW/kVA 2,40/2,67 2,88/3,20 POWER SPEC. VOLTAGE Volt 400/230 400/230 FREQUENCY Hz 50 50 POWER FACTOR cosϕ 0,8/0,9 0,8/0,9 GEAR BOX REVOLUTION rpm 3000 3000 POWER (TRACTOR) HP\kW 14\10 17\12 REVOLUTION PTO SHAFT rpm 429 429 VOLTAGE SYSTEM REGULATOR Compound Compound DIMENSIONS AND WEIGHT LENGTH mm 813 813 WIDTH mm 788 788 HEIGHT mm 930 930 WEIGHT (DRY) Kg 90 125 STANDARD EQUIPMENT, OPTIONS AND ACCESSORIES (x: Standard, o: Optional) MAGNETO THERMAL PROTECTION x x DIFFERENTIAL PROTECTION x x VOLTMETER x x FREQUENCY METER x x RELAY MIN-MAX o o SOCKET TYPE 230V 16A 230V 16A 400V 16A 400V 16A ALTERNATOR AND SOCKET ELECTRIC PROTECTION IP44 IP44 SOCKET PROTECTION IP44 IP44 COP LTP ZG 200/3 ZG 300/3 ZG 300/15 ZG 400/15 ZG 500/15 10,88/13,60 16,00/20,00 16,80/21,00 20,80/26,00 25,60/32,00 4,08/4,53 6,00/6,67 6,30/7,00 7,80/8,67 9,60/10,67 400/230 50 0,8/0,9 3000 24\18 429 Compound 400/230 50 0,8/0,9 3000 35\25 429 Compound 400/230 50 0,8/0,9 1500 32\24 429 Electronic 400/230 50 0,8/0,9 1500 39\28 429 Electronic 400/230 50 0,8/0,9 1500 52\38 420 Electronic 813 788 930 135 813 788 930 175 1000 900 1000 210 1000 900 1000 275 1000 900 1000 315 x x x x o 230V 16A 400V 32A x x x x o 230V 16A 400V 32A x x x x o 230V 16A 400V 32A x x x x o 230V 16A 400V 63A x x x x o 230V 16A CEE 400V 63A IP44 IP44 IP44 IP44 IP44 IP44 IP44 IP44 IP44 IP44 Continuous Power Maximum Power 71 PORTABLE GENSET & POWER EQUIPMENT MP SERIES FOR TRASH AND CLEAN WATER Whenever it is necessary to move large quantities of water, whether during flooding, or simply filling a pond, these petrol powered pumps can move it quickly and efficiently. MP36-2 MP56-3 MP34-2 MP66-3 petrol petrol petrol petrol Semitrash 26 930 3600 Trash 30 700 3600 Trash 27 1340 3600 Honda GX160 163 1 Inclined 4,1 Natural Air Recoil Honda GX160 163 1 Inclined 4,0 Natural Air Recoil Honda GX240 242 1 Inclined 5,9 Natural Air Recoil 313 1,4 3,6 2,5 313 1 3,6 3,5 313 1,5 6 3,9 105 80 106 78 110 83 525 399 476 3 34 653 474 641 2 48 672 516 680 3 59 x x x x x o o x x x x x o o x x x x x o o PUMP TYPE Semitrash HEAD m 30 FLOW L/min 600 REVOLUTIONS rpm 3600 ENGINE MODEL Honda TYPE GX120 DISPLACEMENT cc 118 CYLINDER 1 Inclined POWER kW 2,9 ASPIRATION Natural COOLING SYSTEM Air STARTING SYSTEM Recoil CONSUMPTION CONSUMPTION g/kWh 313 CONSUMPTION at 75% of load L/h 1 TANK CAPACITY L 2,5 RUNNING TIME at 75% of load h 2,5 NOISE EMISSION NOISE LEVEL LWA dB(A) 103 ACOUSTIC PRESSURE at 7 m dB(A) 78 DIMENSIONS AND WEIGHT LENGTH mm 506 WIDTH mm 402 HEIGHT mm 421 INPUT/OUTPUT DIAMETER inch 2 WEIGHT (DRY) Kg 24 STANDARD EQUIPMENT, OPTION AND ACCESSORIES (x: Standard, o: Optional) OIL GUARD SYSTEM x 3 JUBILEE PIPE CLIPS x 2 THREADED COUPLINGS x FILTER x SPARK PLUG TOOL x INLET PIPES 2”, 3” LENGTH 8/25 m o OUTLET PIPE 2”, 3” LENGTH 5/10/50/100 m o LIGHT GLOBE ILLUMINATION NEEDS? Light Globe can illuminate up to 10.500 m2 with a easy-to-use panel that inflates and deflates the globe automatically. GLOBE DIAMETER cm LIT UP AREA m2 LUMEN LAMP TYPE WATT VOLTAGE/FREQ. V/Hz LAMP AUTONOMY HOURS MAX HEIGHT m ELEVATION TYPE CONSUMPTION kW/h OPERATING TEMPERATURE °C POWER NEEDED TO RUN kW WEIGHT Kg PROTECTION GRID FOR THE LAMP TRANSPORT CASE TIMER x o LIGHT GLOBE 80/250 LIGHT GLOBE 100/400 LIGHT GLOBE 140/1000 LIGHT GLOBE 140/2000 80 up to 2.800 25.500 Metal iodide 250 230/50 6.000 2,8 winch 0,4 -20/+40°C 0,85 41 o o 100 up to 4.100 42.500 Metal iodide 400 230/50 6.000 2,8 winch 0,6 -20/+40°C 1,5 41 o o 140 up to 6.100 80.000 Metal iodide 1000 230/50 6.000 6,0 winch 1,7 -20/+40°C 3,0 74 o o x 140 up to 10.500 189.000 Metal iodide 2000 230/50 6.000 6,0 winch 3,0 -20/+40°C 6,0 74 o o x standard optional Case light globe Protection grid Winch Electrical panel 73 PORTABLE GENSET & POWER EQUIPMENT LIGHT TOWER LIGHTING POWER Transportable lighting tower kit, to be installed on GBL or GSL soundproof Pramac range, developed for rental use, public activities and other events. 9 m hydraulic mast with easy erection and turning with redundant safety devices. The 6 floodlights are connected to the generator with only a three phase socket. It's also available as a small portable model used with 5 - 7 kVA generators. LUMEN LAMP TYPE WATT VOLTAGE/FREQ. V/Hz LAMP PROTECTION MAX HEIGHT m ELEVATION TYPE CONSUMPTION kVA/h OPERATING TEMPERATURE °C WEIGHT Kg TURNING ANGLE LIGHT TOWER 500Wx4 LIGHT TOWER 1500Wx6 LIGHT TOWER 400Wx6 single phase three phase three phase 38.000 Halogen 500x4 230/50 IP55 4,6 Winch 2,0 -15/+40 34 - 200.000 Quartz-Iode 1500x6 400/50 IP55 9 Hydraulic 12 -15/+40 882 355 192.000 Metal Halide 400x6 400/50 IP55 9 Hydraulic 4 -15/+40 882 355 HE SERIES THE EASY LIFT The best way to lift a big weight up to 500Kg. A lot of accessories available to allow an easy installation of the hoist. ENGINE ENGINE POWER kW VOLTAGE V FREQUENCY Hz ELEVATION MAX LOAD Kg ELEVATION SPEED m/min MAX ELEVATION m CABLE DIAMETER mm DIMENSION AND WEIGHT LENGTH mm WIDTH mm HEIGHT mm WEIGHT Kg OPTIONS REMOTE CONTROL (RSS) SLIDING TRUCK WEIGHT SUPPORT FOR HOIST WINDOW STRUT INDOOR PROP OUTDOOR PROP SCAFFOLD SUPPORT APS SUPPORT** ** o HE200 HE240 HE300 HE300 HE500 HE500 single phase single phase single phase three phase single phase three phase 0,75 230 50 0,75 230 50 1,10 230 50 1,50 400 50 1,10 230 50 1,85 400 50 200 25 25 5 200 25 25 5 300 25 25 6 300 25 25 6 500 12 25 5 500 27 25 8 690 210 350 37 690 210 350 40 860 320 530 48 860 320 530 50 860 320 530 48 860 320 550 50 o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o under request, to be installed in production only optional 75 ELECTRICAL EQUIPMENT - AMF GSA12L / GBW (15-45p/y) / GBL (30d-42d) CUBICLE Digital instrumentation Engine protection unit Voltmeter Mains voltage Ammeter Frequency meter Hourmeter Battery voltage and intensity ALARMS & SHUTDOWNS Generator voltage out of limits* Over-load* Battery charger alternator failure* Battery voltage out of limits Frequency out of limits* Low oil pressure* High temperature* (not GSA12L) Fail to start External shutdown PROTECTION DEVICES Emergency stop button OTHER FEATURES Acustic alarm Phases detector Battery charger Terminals for genset cubicle connexion Change over contactors with mechanical interlock 5 meters control cables External start capability GSA (22d, 30d, 42d, 65d) / GSL (30d, 42d) / GBW (65p, 80p, 110p) / GSW (15P, 22P) / GSW (15d, 22d) CUBICLE Digital instrumentation Engine protection unit 3 Voltmeter Mains voltage 3 Ammeter Frequency meter Hourmeter Battery voltage and intensity Speed Power (kVA, kW, kVAr, cosϕ) Fuel level gauge Engine temperature indicator (not GSA42d/65d) ALARMS & SHUTDOWNS Generator voltage out of limits* Over-load* Battery charger alternator failure* Battery voltage out of limits Frequency out of limits* Low fuel level* Low oil pressure* High temperature* Low coolant level* (only GBW65d-80d) Fail to start External shutdown PROTECTION DEVICES Emergency stop button OTHER FEATURES Acustic alarm Phases detector Battery charger Terminals for genset cubicle connexion Change over contactors with mechanical interlock 5 meters control cables External start capability GSW (65d, 80d, 110d, 145d, 170d, 195d, 220d) / GSW (530d, 560d) / GSW (275V, 330V, 415V, 450V, 510V, 560V, 590V) CUBICLE Digital instrumentation Engine protection unit 3 Voltmeter Mains voltage 3 Ammeter Frequency meter Hourmeter Battery voltage and intensity Speed Power (kVA, kW, kVAr, cosϕ) Fuel level gauge Oil pressure indicator (on GSW195d) Engine temperature indicator * ALARMS & SHUTDOWNS Generator voltage out of limits* Over-load* Battery charger alternator failure* Battery voltage out of limits Frequency out of limits* Low fuel level* Low oil pressure* High temperature* Low Coolant level* (on GSW195d) Fail to start External shutdown PROTECTION DEVICES Emergency stop button OTHER FEATURES Acustic alarm Phases detector Battery charger Terminals for genset cubicle connexion Change over contactors with mechanical interlock 5 meters control cables CANBUS communication (on GSW275d) External start capability With shutdown protection 77 ELECTRICAL EQUIPMENT - PANELS 1. MCP Analogue CUBICLE Analogue instrumentation Voltmeter Hourmeter ALARMS & SHUTDOWNS Battery charger alternator failure* Low oil pressure* PROTECTION DEVICES III poles Circuit Breaker SOCKETS Single phase CEE socket Three phase CEE socket MANUAL ANALOGUE GBA12L / GBA6d -14d -17d Open set 2. MCP Digital MANUAL DIGITAL GSA22d - 30d - 42d - 65d Open set GLS30d - 42d Open set GSW65d - 80d - 110d - 145d - 170d 195d - 220d Open set CUBICLE Digital instrumentation Engine protection unit 3 Voltmeter 3 Ammeter Frequency meter Hourmeter Battery voltage Speed Power (kVA) Fuel level gauge Engine temperature indicator (not GSA42d/65d) ALARMS & SHUTDOWNS Generator voltage out of limits* Over-load* Battery voltage out of limits Frequency out of limits* Low fuel level* Low oil pressure* High temperature* Fail to start External shutdown PROTECTION DEVICES (III poles on GSA65d) Differential protection Emergency stop button OTHER FEATURES External start capability (optional) 3. MCP Analogue CUBICLE Analogue instrumentation Engine protection unit 3 Voltmeter 3 Ammeter Frequency meter Hourmeter Fuel level gauge Oil pressure indicator Engine temperature indicator ALARMS & SHUTDOWNS Battery charger alternator failure* Low fuel level* Low oil pressure* High temperature* PROTECTION DEVICES (III poles on GSA65d) Differential protection Emergency stop button OTHER FEATURES External start capability (optional) MANUAL GSA22d - 30d - 42d - 65d Open set GLS30d - 42d Open set GSW65d - 80d - 110d - 145d 170d - 195d - 220d 4. ACP AUTOMATIC GSA22d - 30d - 42d - 65d Open set GSL30d - 42d Open set GSW65d - 80d - 110d - 145d 170d - 195d - 220d Open set * With shutdown protection CUBICLE Digital instrumentation Engine protection unit 3 Voltmeter Mains voltage 3 Ammeter Frequency meter Hourmeter Battery voltage and intensity Speed Power (kVA, kW, kVAr, cosϕ) Fuel level gauge Engine temperature indicator (not GSA42d/65d) ALARMS & SHUTDOWNS Generator voltage out of limits* Over-load* Battery charger alternator failure* Battery voltage out of limits Frequency out of limits* Low fuel level* Low oil pressure* High temperature* Fail to start External shutdown PROTECTION DEVICES (III poles on GSA65d) Differential protection Emergency stop button OTHER FEATURES Acustic alarm Phases detector Battery charger Terminals for an external panel connexion (LTS/AMF/ATS) Low potential signallization relay card (optional) External start capability 5. MCP CUBICLE Analogue instrumentation Engine protection unit Voltmeter Ammeter Hourmeter ALARMS & SHUTDOWNS Battery charger alternator failure* Low oil pressure* High temperature* External shutdown PROTECTION DEVICES III poles Circuit Breaker Differential protection Emergency stop button SOCKETS Schuko socket 2 x Single phase CEE socket 2 x Three phase CEE socket MANUAL GBW15 - 45p /y Open set and soundproof GBL30d - 42d Soundproof 6. ACP CUBICLE Digital instrumentation Engine protection unit Voltmeter Mains voltage Ammeter Frequency meter Hourmeter Battery voltage and intensity ALARMS & SHUTDOWNS Generator voltage out of limits* Over-load* Battery charger alternator failure* Battery voltage out of limits Frequency out of limits* Low oil pressure* High temperature* Fail to start External shutdown AUTOMATIC GBL30d - 42d Soundproof GBW15 - 45p /y Open set and Soundproof PROTECTION DEVICES III poles Circuit Breaker Differential protection Emergency stop button SOCKETS Three phase CEE socket OTHER FEATURES Acustic alarm Phases detector Battery charger Terminals for an external panel connexion (LTS/AMF/ATS) External start capability 7. MCP Analogue MANUAL ANALOGUE CUBICLE MCP (ana) Analogue instrumentation Engine protection unit 3 Voltmeter 3 Ammeter Frequency meter Hourmeter Fuel level gauge Oil pressure indicator Engine temperature indicator ALARMS & SHUTDOWNS Battery charger alternator failure* Low fuel level* Low oil pressure* High temperature* PROTECTION DEVICES IV poles Differential protection Emergency stop button OTHER FEATURES External terminal board for load connection External start capability (optional) GSL30d - 42d Soundproof GSW15p - 22p Soundproof GSW15d - 22d Soundproof (optional for GSW65d - 80d - 110d 145d - 170d - 190d - 220d Soundproof) 8. ACP MANUAL / AUTOMATIC GSW530d - 560d Open set and Soundproof GSW275V - 330V - 415V 450V - 510V - 560V -590V Open set and Soundproof * CUBICLE Digital instrumentation Engine protection unit 3 Voltmeter Mains voltage 3 Ammeter Frequency meter Hourmeter Battery voltage and intensity Speed Power (kVA, kW, kVAr, cosϕ) Fuel level gauge Oil pressure indicator Engine temperature indicator ALARMS & SHUTDOWNS Generator voltage out of limits* Over-load* Battery charger alternator failure* Battery voltage out of limits Frequency out of limits* Low fuel level* Low oil pressure* High temperature* Low coolant level* Fail to start External shutdown PROTECTION DEVICES III poles Circuit Breaker (opt IV poles) Differential protection Emergency stop button OTHER FEATURES Acustic alarm Phases detector Battery charger External terminal board for load connection Terminals for an external panel connexion (LTS/AMF/ATS) CANBUS communication External start capability (optional) With shutdown protection 79 9. ACP AUTOMATIC GSW15d - 22d Soundproof GSW15P - 22P Soundproof GSL30d - 42d Soundproof GSW65d - 80d - 110d - 145d - 170d 195d - 220d Soundproof CUBICLE Digital instrumentation Engine protection unit 3 Voltmeter Mains voltage 3 Ammeter Frequency meter Hourmeter Battery voltage and intensity Speed Power (kVA, kW, kVAr, cosϕ) Fuel level gauge Engine temperature indicator ALARMS & SHUTDOWNS Generator voltage out of limits* Over-load* Battery charger alternator failure* Battery voltage out of limits Frequency out of limits* Low fuel level* Low oil pressure* High temperature* Fail to start External shutdown PROTECTION DEVICES IV poles Differential protection Emergency stop button OTHER FEATURES Acustic alarm Phases detector Battery charger External terminal board for load connection Terminals for an external panel connexion (LTS/AMF/ATS) Low potential signallization relay card (optional) External start capability (optional) 10. MCP Analogue CUBICLE MCP (ana) Analogue instrumentation Engine protection unit Voltmeter Ammeter Frequency meter Hourmeter ALARMS & SHUTDOWNS Battery charger alternator failure* Low fuel level* Low oil pressure* High temperature* External shutdown PROTECTION DEVICES IV poles Circuit Breaker Differential protection Emergency stop button SOCKETS Single phase CEE socket Three phase CEE socket OTHER FEATURES External terminal board for load connection MANUAL GBW65p - 80p - 110p Open set and Soundproof 11. ACP AUTOMATIC GBW 65p - 80p - 110p Open set and Soundproof CUBICLE Digital instrumentation Engine protection unit 3 Voltmeter Mains voltage 3 Ammeter Frequency meter Hourmeter Battery voltage and intensity Speed Power (kVA, kW, kVAr, cosϕ) Fuel level gauge Engine temperature indicator ALARMS & SHUTDOWNS Generator voltage out of limits* Over-load* Battery charger alternator failure* Battery voltage out of limits Frequency out of limits* Low fuel level* Low oil pressure* High temperature* Fail to start External shutdown PROTECTION DEVICES IV poles Circuit Breaker Differential protection Emergency stop button OTHER FEATURES Acustic alarm Phases detector Battery charger External terminal board for load connection Terminals for an external panel connexion (LTS/AMF/ATS) External start capability (optional) 12. MCP Digital MANUAL GSW65d - 80d - 110d - 145d - 170d 195d - 220d Soundproof * With shutdown protection CUBICLE Digital instrumentation Engine protection unit 3 Voltmeter 3 Ammeter Frequency meter Hourmeter Battery voltage Speed Power (kVA) Fuel level gauge Oil pressure indicator (standard on GSW195d/220d/275d) Engine temperature indicator ALARMS & SHUTDOWNS Generator voltage out of limits* Over-load* Battery voltage out of limits Frequency out of limits* Low fuel level* Low oil pressure* High temperature* Low Coolant level* (not available on GSW110d/145d/170d) Fail to start External shutdown PROTECTION DEVICES III poles Circuit Breaker (opt IV poles) Differential protection Emergency stop button OTHER FEATURES External terminal board for load connection External start capability (optional) 13. MCP Digital MANUAL GSL30d - 42d Soundproof GSW15P - 22P Soundproof GSW15d - 22d Soundproof CUBICLE Digital instrumentation Engine protection unit 3 Voltmeter 3 Ammeter Frequency meter Hourmeter Battery voltage Speed Power (kVA) Fuel level gauge Engine temperature indicator (only for GSL) ALARMS & SHUTDOWNS Generator voltage out of limits* Over-load* Battery voltage out of limits Frequency out of limits* Low fuel level* Low oil pressure* High temperature* Fail to start External shutdown PROTECTION DEVICES IV poles Differential protection Emergency stop button OTHER FEATURES External terminal board for load connection External start capability (optional) 14. MCP Extended CUBICLE Analogue instrumentation Engine protection unit 3 Voltmeter 3 Ammeter Frequency meter Hourmeter Fuel level gauge MANUAL ALARMS & SHUTDOWNS Battery charger alternator failure* Low fuel level* Low oil pressure* High temperature* External shutdown PROTECTION DEVICES IV poles Circuit Breaker Differential protection Emergency stop button SOCKETS Single phase CEE socket Three phase CEE socket OTHER FEATURES External terminal board for load connection GBW65p - 80p - 110p Open set and Soundproof * With shutdown protection 81 +++ [ Energy mover] EUROPE NORTH AMERICA AFRIQUE PRAMAC FRANCE S.A.S. St. Nizier sous Charlieu, Lyon - France france@pramac.com Tel.: +33 (0) 477 692 020 Fax: +33 (0) 477 601 778 PRAMAC INDUSTRIES Inc. Regional Head Office and USA Sales Office Marietta, Georgia - USA usa@pramac.com Tel: +1 770 218 5430 Fax: +1 770 218 2810 PRAMAC LIFTER AFRIQUE Tr. S.a.r.l. Dakar Yoff - Senegal afrique@pramac.com Tel.: +221 33 849 6232 Fax: +221 33 822 5800 International Sales Office Medley, Florida - USA usa@pramac.com Tel: +1 305 888 9911 Fax: +1 305 888 3711 ASIA PRAMAC LIFTER GmbH Fellbach, Stuttgart - Germany deutschland@pramac.com Tel.: +49 711 517 4290 Fax: +49 711 517 42999 PRAMAC Sp z.o.o. Wroclaw – Poland polska@pramac.com Tel.: +48 71 3321700 Fax: +48 71 3321709 SOUTH AMERICA & CARIBBEAN PRAMAC BRASIL EQUIPAMENTOS LTDA. Sorocaba, SP - BRASIL brasil@pramac.com Tel: +55 15 3225 4415 Fax:+55 15 3225 3852 PRAMAC UK Ltd. Dukestown, Tredegar - United Kingdom uk@pramac.com Tel.: +44 1495 713 300 Fax: +44 1495 718 766 PRAMAC CARIBE C. por A. Los Restauradores, Santo Domingo Dominican Republic s.domingo@pramac.com Tel.: +1 809 531 0067 Fax: +1 809 531 0273 S.C. PRAMAC Group SRL Bucarest - Romania romania@pramac.com Tel.: +40 213001340 Fax: +40 213001340 PRAMAC de Puerto Rico Inc. Barrio Hato Tejas, Bayamón - Puerto Rico info@pramacpr.com Tel.: +1 787 273 3178 Fax: +1 787 273 3179 PRAMAC S.p.A. Headquarters Casole d’Elsa, Siena - Italy info@pramac.com Tel.: +39 0577 9651 Fax: +39 0577 949076 WWW.PRAMAC.COM PRAMAC (ASIA) PTE LTD. Singapore asia@pramac.com Tel.: +65 6558 7888 Fax: +65 6558 7878 PRAMAC (CHINA) LIMITED Hong Kong Regional Head Office Kowloon Bay - Hong Kong asia@pramac.com Tel.: +852 211 638 89 Fax: +852 211 998 22 PRAMAC SIENA (SHANGHAI) TRADING CO. LTD. Shanghai - China asia@pramac.com Tel.: +86 21 5239 1666 Fax: +86 21 5239 3868 The producer reserves the right to introduce changes to models and features without prior notice | Ed.Ⅰ/2007 PRAMAC IBERICA S.A. Balsicas, Murcia - Spain spain@pramac.com Tel.: +34 968 334 900 Fax: +34 968 579 321