SCROL - Gastronomie
Transcription
SCROL - Gastronomie
Gastronomie- Katalog Küchenventilatoren, Abzugshauben und Zubehör KF T120 KUB T120 TGRV TGRT Abzugshaube 1 8 14 15 16 n contact phone.: e-mail: web: +48 58 661 35 28 +48 58 667 81 92 biuro@scrol.pl www.scrol.pl vCard 80-209 Chwaszczyno ul. Polna 11A Always welcome: Mon-Fri 8:00AM - 4:00PM This is a technical catalogue. The company reserves the right to make changes of technical data without prior notice. KF T120 Kitchen fans Caisson de ventilation Küchenabluftboxen KITCHEN FANS Boksventilator Kitchen exhaust units are used for installation where the air is slightly greasy or the air temperature is up to 120°C. Unit has a swing-out door for easy inspection and service. The direction of the door opening is from left to right. The fan is isolated from the casing via connectors and anti-vibration mounts. Impellers: forward-curved blades made of galvanized sheet steel. Motor: Maintenance free, speed controllable, motors safety class IP55, On/Off safety switch. Housing: The casing is manufactured from double-skinned galvanized steel and is insulated with 50 mm mineral wool. Küchenabluftboxen sind zur Förderung von fetthaltiger oder heißer (bis 120°C) Luft geeignet. Die Türen sind ausschwenkbar für leichte Service und Inspektion. Die Türen öffnen sich von links nach rechts. Inklusive Montagerahmen mit Schwingungsdämpfer. Laufrad aus verzinktem Blech, rückwärts gekrümmt Motor: wartungsfrei, Motorschutz IP55, eingebaute Reparaturschalter Gehäuse doppelwandig, aus verzinktem Blech, Schall- und Wärmedämmung 50mm. Caisson de ventilation adapté pour l’extraction de l’air légèrement grasse des cuisines dont la température maximum est de 120°C. Il dispose d’une porte swing-out pour faciliter le contrôle et l’entretien. La direction de l’ouverture de la porte est de gauche à droite. Le ventilateur est isolé du boîtier via des connecteurs et des supports anti-vibration. Turbine à aubes en tôle d’acier galvanisé inclinées en avant. Moteur ne nécessite pas d’entretien, vitesse réglable, protection IP55, interrupteur de proximité. Double paroi en acier galvanisé avec isolation en laine minérale de 50 mm. Boksventilatorerne anvendes i installationer hvor luften er let fedtet eller hvor lufttemperaturen er op til 120°C. Enheden er med ”swing out” for enkel inspektion og service. Døren åbnes fra venstre mod højre. Fodbeslag med vibrationsdæmpere medleveres. Den monterede motor er vedligeholdelsesfri, kapslet IP55. Den komplette enhed er forsynet med sikkerhedsafbryder. Ventilatorhus er udført i dobbeltlags galvaniseret stålplade og isoleret med 50 mm. mineraluld. Accessories 1 Single phase speed controller Three phase speed controller Frequency inverter TGRV TGRT FI KF T120 D C L1 L D1 C1 H* H1 A1 H2 A L2 KITCHEN FANS B Type Dimensions [mm] øD øD1 L L1 L2 H* H1 H2 B A A1 C C1 KF T120 160 200 200 228 173 414 496 355 80 413 123 109 237 195 KF T120 180 200 200 237 182 417 524 382 80 456 145 109 270 213 KF T120 200 200 200 250 196 500 548 407 80 484 145 117 287 228 KF T120 225 250 250 277 222 500 597 456 80 537 161 131 305 253 KF T120 250 315 315 290 136 620 651 500 90 577 170 146 342 278 KF T120 280 315 315 308 253 620 688 537 90 626 180 153 367 304 KF T120 315 315 315 298 242 620 752 600 90 695 195 142 410 339 KF T120 355 400 400 340 285 620 905 655 190 770 211 170 455 370 KF T120 400 400 400 358 298 620 890 640 190 750 202 170 450 355 Type Accessories TGRV TGRT Mains 1X230 V 3X230 V 3X400 V KF T120 160-4L1 2 - ODE-2-12037-1KB12-01 ODE-2-12037-1KB12-01 - KF T120 160-4L3 - 1 ODE-2-12037-1KB12 ODE-2-12037-3K012 ODE-2-14075-3KA12 KF T120 180-4L1 4 - ODE-2-12075-1KB12-01 ODE-2-12075-1KB12-01 - KF T120 180-4L3 - 2 ODE-2-12037-1KB12 ODE-2-12075-3K012 ODE-2-14075-3KA12 KF T120 200-4L1 5 - ODE-2-12075-1KB12-01 ODE-2-12075-1KB12-01 - KF T120 200-4L3 - 3 ODE-2-12075-1KB12 ODE-2-12075-3K012 ODE-2-14075-3KA12 KF T120 225-4L1 11 - ODE-2-22110-1KB42-01 ODE-2-22110-1KB42-01 - KF T120 225-4L3* - - ODE-2-12150-1KB12 ODE-2-12150-3K012 ODE-2-14150-3KA12 KF T120 250-4L1 14 - - - - KF T120 250-4L3* - - ODE-2-22220-1KB42 ODE-2-22220-3KB42 ODE-2-24220-3KA42 KF T120 280-4L3 - - ODE-2-32040-1KB42 ODE-2-32040-3KB42 ODE-2-24400-3KA42 KF T120 315-4L1 3 - ODE-2-12075-1KB12-01 ODE-2-12037-1KB12-01 - KF T120 315-4L3 - 1 ODE-2-12037-1KB12 ODE-2-12037-3K012 ODE-2-14075-3KA12 KF T120 355-4L1 4 - ODE-2-12075-1KB12-01 ODE-2-12075-1KB12-01 - KF T120 355-4L3 - 2 ODE-2-12037-1KB12 ODE-2-12037-3K012 ODE-2-14075-3KA12 KF T120 400-4L1 5 - ODE-2-12075-1KB12-01 ODE-2-12075-1KB12-01 - KF T120 400-4L3 - 3 ODE-2-12075-1KB12 ODE-2-12075-3K012 ODE-2-14075-3KA12 * performance operating area is limited. Do not exceed the normal current, additional overload protection is required. 2 KF T120 Static pressure [Pa] Power [W] KF T120 160-4L1 KF T120 160-4L3 KF T120 180-4L1 KF T120 180-4L3 400 350 300 250 Performance Power consumption 200 150 KITCHEN FANS 100 50 0 3 Voltage/Frequency Power consumption Current Speed [V/Hz] [kW] [A] [min-1] [m3/h] Min/Max ambient air temperature Weight Wiring diagram Protection class: Comply with ERP 2013 160-4L1 [°C] [kg] motor /h] 160-4L1 160-4L3 180-4L1 180-4L3 ~1,230/50 0,22 1,19 1360 829 -40/+40 22 No.1 IP-55 + ~3,400/50 0,18 0,57 1310 849 -40/+40 22 No.3 IP-55 + ~1,230/50 0,4 2,57 1320 1272 -40/+40 25 No.1 IP-55 + ~3,400/50 0,29 1,0 1340 1303 -40/+40 25 No.3 IP-55 + Lwa, dB(A) Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz Inlet 72 65 64 69 60 55 54 48 Outlet 74 66 69 70 59 60 56 50 Surrounding 56 48 51 53 44 40 38 33 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 73 62 64 72 60 55 54 48 Outlet 75 63 69 73 59 60 56 50 Surrounding 56 47 52 53 43 40 38 33 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 75 66 69 73 62 60 56 52 Outlet 77 68 71 75 64 62 58 54 Surrounding 59 53 55 54 47 44 40 37 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 76 65 67 75 63 58 57 51 Outlet 78 68 70 76 65 61 58 53 Surrounding 60 51 54 57 48 42 40 36 8 kHz Measured at 601 m3/h, 100 Pa 160-4L3 Lwa, dB(A) Measured at 621 m3/h, 103 Pa 180-4L1 Lwa, dB(A) Measured at 1037 m3/h, 101 Pa 180-4L3 Lwa, dB(A) Measured at 1052 m3/h, 106 Pa The fan characteristic curves were determined in accordance with EN ISO 5801. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. 3 138 277 416 555 694 833 KF T120 200-4L1 KF T120 200-4L3 KF T120 225-4L1 KF T120 225-4L3 Power [W] 1200 1000 800 Performance Power consumption 600 400 KITCHEN FANS Static pressure [Pa] KF T120 200 0 3 Voltage/Frequency Power consumption Current Speed [V/Hz] [kW] [A] [min-1] [m3/h] Min/Max ambient air temperature Weight Wiring diagram Protection class: Comply with ERP 2013 200-4L1 [°C] [kg] motor /h] 200-4L1 200-4L3 225-4L1 225-4L3 ~1,230/50 0,57 3,08 1360 1794 -40/+40 29 No. 1 IP-55 + ~3,400/50 0,54 1,44 1390 1826 -40/+40 29 No. 3 IP-55 + ~1,230/50 0,97 4,85 1350 2800 -40/+40 34 No. 1 IP-55 + ~3,400/50 0,92 1,72 1430 2860 -40/+40 34 No. 3 IP-55 + Lwa, dB(A) Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz Inlet 79 68 70 78 63 64 60 54 Outlet 81 73 74 79 67 63 60 59 Surrounding 63 55 57 61 49 46 43 40 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 79 69 72 77 65 63 58 55 Outlet 82 73 75 80 66 64 60 58 Surrounding 64 56 58 62 49 47 42 40 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 82 70 76 80 70 67 63 58 Outlet 84 74 77 82 71 68 64 60 Surrounding 68 57 62 65 54 50 46 43 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 83 72 74 81 70 68 63 60 Outlet 85 75 79 82 71 69 65 61 Surrounding 69 59 63 66 54 51 47 44 8 kHz Measured at 1541 m3/h, 100 Pa 200-4L3 Lwa, dB(A) Measured at 1570 m3/h, 101 Pa 225-4L1 Lwa, dB(A) Measured at 2492 m3/h, 100 Pa 225-4L3 Lwa, dB(A) Measured at 2585 m3/h, 102 Pa The fan characteristic curves were determined in accordance with EN ISO 5801. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. 4 KF T120 Static pressure [Pa] Power [W] KF T120 250-4L1 KF T120 250-4L3 KF T120 280-4L3 KF T120 315-4L1 KF T120 315-4L3 KITCHEN FANS Performance Power consumption Not operating zone 3 Voltage/Frequency Power consumption Current Speed [V/Hz] [kW] [A] [min-1] [m3/h] Min/Max ambient air temperature Weight Wiring diagram Protection class: Comply with ERP 2013 250-4L1 [°C] [kg] motor /h] 250-4L1 250-4L3 280-4L3 315-4L1 315-4L3 ~1,230/50 1,94 9,3 1420 4106 -40/+40 44 No.2 IP-55 + ~3,400/50 1,6 3,37 1430 3860 -40/+40 55 No.3 IP-55 + ~3,400/50 2,66 4,7 1440 5236 -40/+40 45 No.3 IP-55 + ~1,230/50 0,32 1,77 1350 1693 -40/+40 45 No.1 IP-55 + ~3,400/50 0,18 0,68 1330 1676 -40/+40 45 No.3 IP-55 + Lwa, dB(A) Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz Inlet 85 75 79 82 73 71 66 61 Outlet 87 77 81 84 75 72 68 65 Surrounding 71 61 66 67 58 54 50 47 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 86 78 80 83 73 70 67 63 Outlet 88 80 81 86 75 74 66 65 Surrounding 72 64 66 68 59 56 49 48 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 90 82 83 88 75 71 68 67 Outlet 92 85 83 89 78 76 68 69 Surrounding 74 67 68 71 60 56 51 50 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 78 68 73 74 66 63 57 54 Outlet 80 69 75 77 68 65 59 56 Surrounding 63 53 60 59 51 47 41 39 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 78 67 73 74 66 64 56 54 Outlet 80 69 74 77 67 65 59 55 Surrounding 63 53 59 59 50 47 40 38 8 kHz Measured at 3824 m3/h, 100 Pa 250-4L3 Lwa, dB(A) Measured at 3860 m3/h, 190 Pa 280-4L3 Lwa, dB(A) Measured at 5077 m3/h, 100 Pa 315-4L1 Lwa, dB(A) Measured at 1407 m3/h, 101 Pa 315-4L3 Lwa, dB(A) Measured at 1401 m3/h, 100 Pa The fan characteristic curves were determined in accordance with EN ISO 5801. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. 5 138 277 416 555 694 833 972 KF T120 355-4L1 KF T120 355-4L3 KF T120 400-4L1 KF T120 400-4L3 1111 600 Power [W] 500 400 300 Performance Power consumption 200 KITCHEN FANS Static pressure [Pa] KF T120 100 0 3 Voltage/Frequency Power consumption Current Speed 355-4L1 ~1,230/50 0,4 2,5 1320 2499 -40/+40 53 No.1 IP-55 + [V/Hz] [kW] [A] [min-1] [m3/h] Min/Max ambient air temperature Weight Wiring diagram Protection class: Comply with ERP 2013 355-4L1 /h] [°C] [kg] motor 355-4L3 ~3,400/50 0,29 0,98 1340 2561 -40/+40 53 No.3 IP-55 + 400-4L1 ~1,230/50 0,54 3,05 1360 3374 -40/+40 56 No.1 IP-55 + 400-4L3 ~3,400/50 0,47 1,45 1390 3487 -40/+40 56 No.3 IP-55 + Lwa, dB(A) Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz Inlet 84 74 77 82 70 69 63 58 Outlet 85 76 79 83 72 71 65 60 Surrounding 67 60 61 63 55 53 47 43 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 84 75 78 82 71 70 63 58 Outlet 86 77 79 83 73 72 65 61 Surrounding 67 61 62 63 56 54 47 43 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 86 77 75 82 79 74 68 67 Outlet 88 78 81 85 77 74 70 69 Surrounding 71 62 64 67 62 57 52 50 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 86 77 76 82 80 74 69 68 Outlet 88 79 81 85 78 75 71 70 Surrounding 71 63 65 67 63 58 53 52 8 kHz Measured at 2111 m3/h, 120 Pa 355-4L3 Lwa, dB(A) Measured at 2219 m3/h, 104 Pa 400-4L1 Lwa, dB(A) Measured at 2915 m3/h, 141 Pa 400-4L3 Lwa, dB(A) Measured at 2956 m3/h, 134 Pa The fan characteristic curves were determined in accordance with EN ISO 5801. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. 6 Wiring diagram No. 1 KITCHEN FANS Static pressure [Pa] KF T120 Wiring diagram No. 2 3 /h] Wiring diagram No. 3 Q - switch M - fan motor 7 KUB T120 Kitchen fans Caisson de ventilation Küchenabluftboxen KITCHEN FANS Boksventilator Kitchen exhaust units are used for installation where the air is slightly greasy or the air temperature is up to 120°C.. Typical applications are to exhaust kitchens, production shops and other areas where polluted air has to be exhausted. Motors are outside of the Impellers: backward - curved blades. Motor: IEC standard motor with external rotor, speed controllable, On/Off safety switch, built-in thermal-contacts. Housing: The casing consists of an aluminium frame and double skin, galvanised steel panels with 25 mm mineral wool insulation. Caisson de ventilation adapté pour l’extraction de l’air dont la température maximum est de 120°C. Il est utilisé dans les ateliers de productions des cuisines en extraction de l’air légèrement grasse. à rotor extérieur, vitesse réglable, interrupteur de proximité, thermocontacts intégrés. Caisson de ventilation est constitué d’un châssis en aluminium et double peau, des panneaux en acier galvanisé avec isolation en laine minérale de 25 mm. Küchenabluftboxen sind zur Förderung von fetthaltiger oder heißer (bis 120°C) Luft geeignet. Geeignet für Küchenabluft, Produktionund andere Räume, wo man Abluft braucht. Abnehmbare Paneele erleichtert den Einbau. Ventilator-Luftstromrichtung – 90o. Laufrad rückwärts gekrümmt Motor: IEC Standart-Motor mit Außenrotor, Thermo-Kontake und Reparaturschalter eingebaut. aus verzinktem Blech mit 25 mm Schall- und Wärmedämmung. Boksventilatorerne anvendes i installationer hvor luften er let fedtet eller hvor lufttemperaturen er op til 120°C.Typiske anvendelsesområder er: køkkener, værksteder samt andre områder hvor der er behov for at få fjernet forurenet luft. Motoren er monteret udenfor lation. Ventilatorafkast er vinklet 90° i forhold til indløb. Ventilatorhjul: Bagoverbøjede blade. Motor: IEC standard motorer med ekstern rotor, indbyggede termokontakter, regulerbare og forsynet med sikkerhedsafbryder. Ventilatorhus udført med Alu-ramme og dobbeltlagede galvaniserede stålpaneler, isoleret med 25 mm. mineraluld. Accessories 8 Single phase speed controller Three phase speed controller Frequency inverter TGRV TGRT FI Flange - adapter PR KITCHEN FANS KUB T120 Type Dimensions [mm] øD L □ L1 □H A B C KUB T120 355 355 570 500 500 225 540 420 KUB T120 400 400 740 670 670 240 712 590 KUB T120 450 450 740 670 670 275 712 590 KUB T120 500 500 740 670 670 310 712 590 KUB T120 560 560 870 800 800 355 840 720 KUB T120 630 630 940 865 865 385 905 785 Type Accessories TGRV TGRT 4 - KUB T120 355-4L3 - 2 KUB T120 400-4L1 5 - KUB T120 400-4L3 - 2 KUB T120 450-4L1 11 - KUB T120 355-4L1 Mains PR 1X230 V 3X230 V 3X400 V ODE-2-12075-1KB12-01 ODE-2-12075-1KB12-01 - ODE-2-12037-1KB12 ODE-2-12075-3K012 ODE-2-14075-3KA12 420x420-355 ODE-2-12075-1KB12 ODE-2-12075-1KB12-01 - 590x590-400 ODE-2-12075-1KB12 ODE-2-12075-3K012 ODE-2-14075-3KA12 590x590-400 ODE-2-22110-1KB42-01 ODE-2-22110-1KB42-01 - 590x590-450 420x420-355 KUB T120 450-4L3* - - ODE-2-12150-1KB12 ODE-2-12150-3K012 ODE-2-14150-3KA12 590x590-450 KUB T120 500-4L1 14 - ODE-2-22220-1KB42 ODE-2-22220-3K042 - 590x590-500 KUB T120 500-4L3* - - ODE-2-12150-1KB12 ODE-2-22150-3KB42 ODE-2-14150-3KA12 590x590-500 KUB T120 560-4L3* - - ODE-2-32040-1KB42 ODE-2-32040-3K042 ODE-2-24400-3KA42 695x695-560 KUB T120 630-4L3* - - - - ODE-2-34055-3KA42 790x790-630 * Speed is controlled only with the frequency inverter. Motors standard IE2. 9 138 277 416 555 694 833 972 KUB T120 355-4L1 KUB T120 355-4L3 KUB T120 400-4L1 KUB T120 400-4L3 1111 1200 Power [W] Static pressure [Pa] KUB T120 1000 800 Performance Power consumption 600 KITCHEN FANS 400 200 0 3 Voltage/Frequency Power consumption Current Speed [V/Hz] [kW] [A] [min-1] [m3/h] Min/Max ambient air temperature Weight Wiring diagram Protection class: Comply with ERP 2013 [°C] [kg] motor /h] 355-4L1 355-4L3 400-4L1 400-4L3 ~1,230/50 0,44 2,55 1320 2522 -40/+40 33 No. 1 IP-55 + ~3,400/50 0,35 1,06 1340 2619 -40/+40 33 No. 3/4 IP-55 + ~1,230/50 0,59 3,17 1360 3892 -40/+40 55 No. 1 IP-55 + ~3,400/50 0,54 1,38 1390 3976 -40/+40 55 No. 3/4 IP-55 + The provided technical data is by using #3 el. connection scheme. Using #4 el. connection scheme, technical data will be different. 355-4L1 Lwa, dB(A) Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz Inlet 68 55 62 64 60 59 55 46 Outlet 71 58 61 67 65 60 56 48 Surrounding 55 42 48 51 47 43 39 35 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 68 56 62 64 60 59 56 47 Outlet 71 59 62 67 65 61 56 49 Surrounding 55 43 48 52 47 43 40 36 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 72 60 64 67 66 62 57 51 Outlet 74 62 66 70 68 64 59 52 Surrounding 59 48 53 55 53 48 43 37 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 72 61 65 67 66 63 57 52 Outlet 76 63 66 74 68 65 60 54 Surrounding 59 47 54 55 52 49 43 37 8 kHz Measured at 2113 m3/h, 120 Pa 355-4L3 Lwa, dB(A) Measured at 2241 m3/h, 120 Pa 400-4L1 Lwa, dB(A) Measured at 3482 m3/h, 121 Pa 400-4L3 Lwa, dB(A) Measured at 3583 m3/h, 120 Pa The fan characteristic curves were determined in accordance with EN ISO 5801. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. 10 277 555 833 1111 1388 1666 1944 KUB T120 450-4L1 KUB T120 450-4L3 KUB T120 500-4L1 KUB T120 500-4L3 2222 3000 Power [W] 2500 2000 1500 Performance Power consumption 1000 KITCHEN FANS Static pressure [Pa] KUB T120 500 1000 2000 3000 4000 5000 6000 0 8000 7000 3 Voltage/Frequency Power consumption Current Speed [V/Hz] [kW] [A] [min-1] [m3/h] Min/Max ambient air temperature Weight Wiring diagram Protection class: Comply with ERP 2013 [°C] [kg] motor /h] 450-4L1 450-4L3 500-4L1 500-4L3 ~1,230/50 1,14 6,55 1420 5477 -40/+40 62 No. 2 IP-55 + ~3,400/50 0,92 2,13 1430 5645 -40/+40 62 No. 3 IP-55 + ~1,230/50 1,6 7,95 1420 7045 -40/+40 66 No. 2 IP-55 + ~3,400/50 1,44 3,08 1430 7404 -40/+40 66 No. 3/4 IP-55 + The provided technical data is by using #3 el. connection scheme. Using #4 el. connection scheme, technical data will be different. 450-4L1 Lwa, dB(A) Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz Inlet 75 64 68 70 69 66 60 54 Outlet 77 66 70 72 70 68 64 57 Surrounding 62 51 56 57 54 50 45 40 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 76 65 70 72 69 67 61 55 Outlet 78 66 71 73 70 69 66 58 Surrounding 62 51 57 58 54 51 47 41 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 79 70 71 75 72 69 63 59 Outlet 81 73 72 76 75 70 63 62 Surrounding 64 56 57 60 58 53 46 44 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 79 70 72 75 73 69 64 60 Outlet 81 73 73 76 75 72 65 63 Surrounding 65 56 58 60 58 54 47 45 8 kHz Measured at 5080 m3/h, 101 Pa 450-4L3 Lwa, dB(A) Measured at 5277 m3/h, 99 Pa 500-4L1 Lwa, dB(A) Measured at 6472 m3/h, 119 Pa 500-4L3 Lwa, dB(A) Measured at 6881 m3/h, 122 Pa The fan characteristic curves were determined in accordance with EN ISO 5801. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. 11 KUB T120 Power [W] Static pressure [Pa] KITCHEN FANS KUB T120 560-4L3 KUB T120 630-4L3 Performance Power consumption 3 Voltage/Frequency Power consumption Current Speed /h] 250-4L1 250-4L3 [V/Hz] [kW] [A] [min-1] [m3/h] Min/Max ambient air temperature Weight Wiring diagram Protection class: Comply with ERP 2013 [°C] [kg] motor 560-4L3 630-4L3 ~3,400/50 2,5 5,04 1440 10942 -40/+40 98 No. 3/4 IP-55 + ~3,400/50 4,88 8,9 1450 15100 -40/+40 134 No. 5 IP-55 + The provided technical data is by using #3 el. connection scheme. Using #4 el. connection scheme, technical data will be different. 560-4L3 Lwa, dB(A) Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz Inlet 85 74 78 80 79 76 61 64 Outlet 87 76 80 82 81 78 74 66 Surrounding 71 60 65 66 64 60 51 49 Lwa total, dB(A) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 91 80 85 86 84 81 67 65 Outlet 94 82 87 90 87 84 78 73 Surrounding 78 68 72 73 70 65 59 55 8 kHz Measured at 10307 m3/h, 145 Pa 630-4L3 Lwa, dB(A) Measured at 14159m3/h, 239 Pa The fan characteristic curves were determined in accordance with EN ISO 5801. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. 12 Wiring diagram No. 1 Wiring diagram No. 2 3 Wiring diagram No.4 Wiring diagram No. 3 KITCHEN FANS Static pressure [Pa] KUB T120 /h] Wiring diagram No. 5 13 TGRV Single phase speed controller Transformer controllers are designed to change motor rotating speed by changing voltage. All controllers are with motors and transformers thermo protection function. 1 phase controllers are with power supply fault protection. When power supply recovered, controller did not switch on previous step until ACCESSORIES and are changed with rotary switch. Controllers also have power indication led. All controllers have 230 VAC output for connection servo motors, actuators, heaters relays and etc. To one controller more than one motor can be connected, if total current of all controllers is less than maximum controller current. In this case all motors thermo protections must be connected in series. Les régulateurs de vitesse monophasés conversationnels une fonction de protection du moteur et du transformateur contre la surchauffe. Les régulateurs ont une protection contre la disparition de la phase. Lorsque l’alimentation est rétablie, le régulateur ne se connecte pas à l’ancien étage tant qu’il n’est pas déconnecté et de nouveau connecté à l’étage souhaité. Les étages ont des tensions la tension est aussi montée dans les régulateurs. Tous les régulateurs ont une sortie 230 VAC pour bloquer et connecter les commandes des moteurs et des batteries terminales. Il est possible de piloter plusieurs moteurs avec un régulateur de vitesse si la consommation totale du courant de l’ensemble des moteurs n’excède pas le courant maximal du régulateur. Dans ce cas, les protections thermiques de l’ensemble des moteurs doivent être raccordées de manière continue. Dimensions Type 14 Max. current Voltage A [mm] B [mm] C [mm] Weight [kg] TGRV 1,5 1,5 A 230V/50Hz 178 155 99 2,6 TGRV 2 2,0 A 230V/50Hz 178 155 99 3,0 TGRV 3 3,0 A 230V/50Hz 178 155 99 3,5 TGRV 4 4,0 A 230V/50Hz 178 155 150 4,4 TGRV 5 5,0 A 230V/50Hz 178 155 150 4,9 TGRV 7 7,0 A 230V/50Hz 244 184 178 7,3 TGRV 11 11,0 A 230V/50Hz 244 184 178 9,5 TGRV 14 14,0 A 230V/50Hz 244 184 178 10,4 Traforegler sind zur Änderung von Drehgeschwindigkeit der Elektromotoren durch Spannungsänderung bestimmt. Alle Regler haben Schutzfunktion gegen Motor- und Transformatorüberhitzung. Einphasige Regler haben den Schutz gegen Verschwinden der Phase. Wenn sich die Speisung wiederherstellt, schaltet der Regler in frühere Stufe nicht, bis er nicht ausgeschaltet und wieder für gewünschte Stufe eingeschaltet wird. Die Stufen haben feste Spannungen und werden mit einem Drehschalter umgeschaltet. In Reglern sind auch Kontrollleuchten für Spannungsindikation eingerichtet. Alle Regler haben einen 230 VAC-Ausgang für Anschluss von Antrieben, von denen die Motoren bedient, die Wärmer blockiert usw. werden. Mit einem Geschwindigkeitsregler können mehrere Motore gesteuert werden, falls gesamter Stromverbrauch sämtlicher Motoren den maximalen Reglerstrom nicht überschreitet. In diesem Fall müssen Thermoschütze sämtlicher Motoren folgerichtig geschlossen werden. Transformerreguleringer er designet til at ændre motorens omdrejningstal ved at ændre på spændingen. Alle reguleringer er med indbygget motor- og reguleringsbeskyttelse. 1-Fasede reguleringer er forsynet med beskyttelse mod fejl i forsyningsspændingen. Manuel reset forhindrer en utilsigtet genstart. Reguleringen er med faste spændingstrin og vælges med drejeknap. Alle reguleringer er forsynede med fast 230V AC udtag. En ikke overstiger reguleringens maksimale strømgrænse. Technical data • Input 230V / 50 Hz • 5 steps: 230V / 170V / 140V / 120V / 80V • Casing protection rating - IP 44 • Enclosure: Plastic • Max. ambient temperature +400C • Auto-transformer completely impregnated with resin • 5-step switch and operating lamp • Additional connection for servo motor 230V / 50Hz, 0,5A • Full motor protection, re-set is locked through thermal contacts lead out of the motor • Speed controllers conform with LST EN 600335-1:2003+A11:2004+A 1:2005+A12:2006+A2:2007 standards and are CE marked. TGRT Three phase speed controller and are changed with rotary switch. Controllers also have power indication led. All controllers have 230 VAC output for connection servo motors, actuators, heaters relays and etc. To one controller more than one motor can be connected, if total current of all controllers is less than maximum controller current. In this case all motors thermo protections must be connected in series. Les régulateurs de vitesse triphasés conversationnels sont fonction de protection du moteur et du transformateur contre la surchauffe. Les régulateurs ont une protection contre la disparition de la phase. Lorsque l’alimentation est rétablie, le régulateur ne se connecte pas à l’ancien étage tant qu’il n’est pas déconnecté et de nouveau connecté à l’étage souhaité. Les étages ont des tensions la tension est aussi montée dans les régulateurs. Tous les régulateurs ont une sortie 230 VAC pour bloquer et connecter les commandes des moteurs et des batteries terminales. Il est possible de piloter plusieurs moteurs avec un régulateur de vitesse si la consommation totale du courant de l’ensemble des moteurs n’excède pas le courant maximal du régulateur. Dans ce cas, les protections thermiques de l’ensemble des moteurs doivent être raccordées de manière continue. Dimensions Type Max. current Voltage A [mm] B [mm] C [mm] Weight TGRT 1 1A 400V/50Hz 335 245 133 6,3 kg TGRT 2 2,0 A 400V/50Hz 335 245 133 8,1 kg TGRT 3 3,0 A 400V/50Hz 335 245 133 10,7 kg TGRT 4 4,0 A 400V/50Hz 335 245 133 14,6 kg TGRT 5 5,0 A 400V/50Hz 300 290 160 18,7 kg TGRT 7 7,0 A 400V/50Hz 365 320 190 24,7 kg TGRT 11 11,0 A 400V/50Hz 365 320 190 34,1 kg TGRT 14 14,0 A 400V/50Hz 365 320 190 37,2 kg Traforegler sind zur Änderung von Drehgeschwindigkeit der Elektromotoren durch Spannungsänderung bestimmt. Alle Regler haben Schutzfunktion gegen Motor- und Transformatorüberhitzung. Dreiphasige Regler haben den Schutz gegen Verschwinden der Phase. Wenn sich die Speisung wiederherstellt, schaltet der Regler in frühere Stufe nicht, bis er nicht ausgeschaltet und wieder für gewünschte Stufe eingeschaltet wird. Die Stufen haben feste Spannungen und werden mit einem Drehschalter umgeschaltet. In Reglern sind auch Kontrollleuchten für Spannungsindikation eingerichtet. Alle Regler haben einen 230 VAC-Ausgang für Anschluss von Antrieben, von denen die Motoren bedient, die Wärmer blockiert usw. werden. Mit einem Geschwindigkeitsregler können mehrere Motore gesteuert werden, falls gesamter Stromverbrauch sämtlicher Motoren den maximalen Reglerstrom nicht überschreitet. In diesem Fall müssen Thermoschütze sämtlicher Motoren folgerichtig geschlossen werden. ACCESSORIES Transformer controllers are designed to change motor rotating speed by changing voltage. All controllers are with motors and transformers thermo protection function. 3 phase controllers are with power supply fault protection. When power supply recovered, controller did not switch on previous step until Transformerreguleringer er designet til at ændre motorens omdrejningstal ved at ændre på spændingen. Alle reguleringer er med indbygget motor- og reguleringsbeskyttelse. 3-Fasede reguleringer er forsynet med beskyttelse mod fejl i forsyningsspændingen. Manuel reset forhindrer en utilsigtet genstart. Reguleringen er med faste spændingstrin og vælges med drejeknap. Alle reguleringer er forsynede med fast 230V AC udtag. En ikke overstiger reguleringens maksimale strømgrænse. Technical data • Input 400V / 50Hz • 5 steps: 400V / 270V / 220V / 170V / 130V • Casing protection rating - IP 44 • Enclosure: Plastic (TGRT 1-4) / steel sheet, powder coated (TGRT 5-14) • Max. ambient temperature +400C • Auto-transformer completely impregnated with resin, 2 transformers • 5-step switch and operating lamp • Additional connection for servo motor 230V / 50Hz, 0,5A • Full motor protection, re-set is locked through thermal contacts lead out of the motor • Speed controllers conform with LST EN 600335-1:2003+A11:2004+A1 :2005+A12:2006+A2:2007 standards and are CE marked 15 Abzugshaube Typ KOW-10 Methode der Bestellung: Standardabmessungen: H = 550 L = 1000 - 3000 B = 700 - 1200 B x L x H (Lage und Durchmesser des Anschlusstutzens) - Säurebeständige Blech - verfügbar in den Versionen: - ohne Filter und Beleuchtung - mit Filter - mit Filter und Beleuchtung Abzugshaube Typ KOW-20 Methode der Bestellung: Standardabmessungen: H = 550 L = 1000 - 3000 B = 600 - 1200 B x L x H (Lage und Durchmesser des Anschlusstutzens) - Säurebeständige Blech - verfügbar in den Versionen: - ohne Filter und Beleuchtung - mit Filter - mit Filter und Beleuchtung Abzugshaube Typ KOW-35 Methode der Bestellung: Standardabmessungen: H = 550 L = 1000 - 3000 B = 600 - 1200 B x L x H (Lage und Durchmesser des Anschlusstutzens) 16 - Säurebeständige Blech - verfügbar in den Versionen: - ohne Filter und Beleuchtung - mit Filter - mit Filter und Beleuchtung Abzugshaube Typ KOW-40 - Säurebeständige Blech - verfügbar in den Versionen: - ohne Filter und Beleuchtung - mit Filter - mit Filter und Beleuchtung Methode der Bestellung: Standardabmessungen: H = 550 L = 1000 - 3000 B = 1200 - 2100 B x L x H (Lage und Durchmesser des Anschlusstutzens) Abzugshaube Typ KOW-50 - Säurebeständige Blech - verfügbar in den Versionen: - ohne Filter und Beleuchtung - mit Filter - mit Filter und Beleuchtung Methode der Bestellung: Standardabmessungen: H = 550 L = 1000 - 3000 B = 1200 - 2000 B x L x H (Lage und Durchmesser des Anschlusstutzens) Abzugshaube Typ KOW-60 - Säurebeständige Blech - verfügbar in den Versionen: - ohne Filter und Beleuchtung - mit Filter - mit Filter und Beleuchtung Methode der Bestellung: Standardabmessungen: H = 550 L = 1000 - 3000 B = 1200 - 2000 B x L x H (Lage und Durchmesser des Anschlusstutzens) 17